WorldWideScience

Sample records for pwm converters operating

  1. Large-signal stability analysis of PWM converters

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, P.T. [Philips Labs., Briarcliff Manor, NY (United States); Cho, B.H. [Seoul National Univ. (Korea, Republic of). Dept. of Electrical Engineering

    1995-12-31

    Investigation of the effects of existing nonlinearities on the stability of PWM converters is performed. The bilinear structure, the duty cycle saturation, and the opamp saturation are the principal nonlinearities in PWM converters. These nonlinearities are incorporated in the large-signal analytical models of PWM converters, and the basic input-output stability theory is applied to analyze their stability. Design and optimization of the small-signal loop gains to counteract the undesirable nonlinear effects are also discussed.

  2. Soft-switching PWM full-bridge converters topologies, control, and design

    CERN Document Server

    Ruan, Xinbo

    2014-01-01

    Soft-switching PWM full-bridge converters have been widely used in medium-to-high power dc-dc conversions for topological simplicity, easy control and high efficiency. Early works on soft-switching PWM full-bridge converter by many researchers included various topologies and modulation strategies.  However, these works were scattered, and the relationship among these topologies and modulation strategies had not been revealed. This book intends to describe systematically the soft-switching techniques for pulse-width modulation (PWM) full-bridge converters, including the topologies, control and

  3. Step-down switched-capacitor quasi-resonant PWM converter with continuous conversion ratio

    NARCIS (Netherlands)

    Turhan, M.; Hendrix, M.A.M.; Duarte, J.L.

    2015-01-01

    Inherent disadvantages of conventional switched-capacitor converters (SCC) are their discrete conversion ratio and inefficient energy transfer. In order to soften these downsides, a step-down switched-capacitor quasi-resonant PWM converter is proposed. The operation modes and steady-state

  4. Development of a current-type PWM converter with high power factor. 1

    International Nuclear Information System (INIS)

    Miura, Yushi; Matsukawa, Makoto; Miyachi, Kengo; Kimura, Toyoaki

    1998-01-01

    A power supply system for superconducting poloidal field coils of a next generation tokamak-type fusion device can be operated on the relatively low voltage for the duration of discharge except the plasma initiation. In the case of the conventional phase-controlled thyristor converters are adopted in such a system, the input power factor would be low in average, and a reactive power fluctuation caused by the change of DC output voltage may produce serious effects on the commercial transmission line. From the above viewpoint, a current-type PWM (Pulse Width Modulation) converter, which can work with the power factor of unity for the input power, is regarded as one of the promising candidates of the converters for the power supplies of next generation fusion devices. Hence, a 100kW-class current-type PWM converter has been developed by using IGBT (Insulated Gate Bipolar Transistor) as switching devices. In this development, the basic performance has been preliminary investigated whether this converter is applicable to the power supply for the next generation fusion device. In addition, two different PWM control methods were examined whether these methods can realize a unit power factor and suppress the transient oscillation of converter input current at the same time in case that the reference of DC output current is changed rapidly. (author)

  5. Soft Switching Full-Bridge PWM DC/DC Converter Using Secondary Snubber

    Directory of Open Access Journals (Sweden)

    Jaroslav Dudrik

    2009-05-01

    Full Text Available A novel full-bridge PWM DC/DCconverter with controlled secondary side rectifier usingsecondary snubber is presented in this paper.Limitation of the circulating current as well as softswitching for all power switches of the inverter isachieved for full load range from no-load to shortcircuit by using controlled rectifier and snubber on thesecondary side. Phase shift PWM control strategy isused for the converter. The principle of operation isexplained and analyzed and the experimental resultson a 1kW, 50 kHz laboratory model of the converterare presented.

  6. Soft switching PWM isolated boost converter for fuel cell application

    Energy Technology Data Exchange (ETDEWEB)

    Rezaei, M.; Adib, E. [Isfahan Univ. of Technology, Isfahan (Iran, Islamic Republic of)

    2009-07-01

    This presentation introduced a newly developed soft switching, isolated boost type converter for fuel cell applications. With a simple PWM control circuit, the converter achieves zero voltage switching the main switch. Since the auxiliary circuit is soft switched, the converter can operate at high powers which make it suitable for fuel cell applications. In particular, the converter is suitable for the interface of fuel cell and inverters because of its high voltage gain and isolation between input and output sources. In addition, the input current of the converter (current drained from the fuel cell) is almost constant since it is a boost type converter. The converter was analyzed and the simulation results validate the theoretical analysis.

  7. Research on Single-Phase PWM Converter with Reverse Conducting IGBT Based on Loss Threshold Desaturation Control

    Directory of Open Access Journals (Sweden)

    Xianjin Huang

    2017-11-01

    Full Text Available In the application of vehicle power supply and distributed power generation, there are strict requirements for the pulse width modulation (PWM converter regarding power density and reliability. When compared with the conventional insulated gate bipolar transistor (IGBT module, the Reverse Conducting-Insulated Gate Bipolar Transistor (RC-IGBT with the same package has a lower thermal resistance and higher current tolerance. By applying the gate desaturation control, the reverse recovery loss of the RC-IGBT diode may be reduced. In this paper, a loss threshold desaturation control method is studied to improve the output characteristics of the single-phase PWM converter with a low switching frequency. The gate desaturation control characteristics of the RC-IGBT’s diode are studied. A proper current limit is set to avoid the ineffective infliction of the desaturation pulse, while the bridge arm current crosses zero. The expectation of optimized loss decrease is obtained, and the better performance for the RC-IGBTs of the single-phase PWM converter is achieved through the optimized desaturation pulse distribution. Finally, the improved predictive current control algorithm that is applied to the PWM converter with RC-IGBTs is simulated, and is operated and tested on the scaled reduced power platform. The results prove that the gate desaturation control with the improved predictive current algorithm may effectively improve the RC-IGBT’s characteristics, and realize the stable output of the PWM converter.

  8. A ZVT–ZCT PWM synchronous buck converter with a simple passive auxiliary circuit for reduction of losses and efficiency enhancement

    Directory of Open Access Journals (Sweden)

    S. Shiva Kumar

    2015-06-01

    Full Text Available In this paper, a Zero-Voltage-Transition (ZVT–Zero-Current Transition (ZCT Pulse-width Modulated (PWM synchronous buck converter (SBC, with a simple passive auxiliary circuit is proposed, which reduces the stresses and improves the efficiency by pacifying the conduction losses compared to a traditional PWM converter, typically suitable for photovoltaic applications. The important design feature of ZVT–ZCT PWM SBC converters is placement of resonant components that mollifies the conduction losses. Due to the ZVT–ZCT, the resonant components with low values are used, thereby resulting in the increase of switching frequency. The ZVT–ZCT operation of the proposed converter is presented through theoretical analysis. The characteristics of the proposed converter are verified with the simulation in the PSIM co-simulated with MATLAB/SIMULINK environment and implemented experimentally.

  9. A ZVS PWM control strategy with balanced capacitor current for half-bridge three-level DC/DC converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    The capacitor current would be imbalanced under the conventional control strategy in the half-bridge three-level (HBTL) DC/DC converter due to the effect of the output inductance of the power supply and the input line inductance, which would affect the converter's reliability. This paper proposes...... a pulse-wide modulation (PWM) strategy composed of two operation modes for the HBTL DC/DC converter, which can realize the zero-voltage switching (ZVS) for the efficiency improvement. In addition, a capacitor current balancing control is proposed by alternating the two operation modes of the proposed ZVS...... PWM strategy, which can eliminate the current imbalance among the two input capacitors. Therefore, the proposed control strategy can improve the converter's performance and reliability in: 1) reducing the switching losses and noises of the power switches; 2) balancing the thermal stresses...

  10. Logo2PWM: a tool to convert sequence logo to position weight matrix.

    Science.gov (United States)

    Gao, Zhen; Liu, Lu; Ruan, Jianhua

    2017-10-03

    position weight matrix (PWM) and sequence logo are the most widely used representations of transcription factor binding site (TFBS) in biological sequences. Sequence logo - a graphical representation of PWM, has been widely used in scientific publications and reports, due to its easiness of human perception, rich information, and simple format. Different from sequence logo, PWM works great as a precise and compact digitalized form, which can be easily used by a variety of motif analysis software. There are a few available tools to generate sequence logos from PWM; however, no tool does the reverse. Such tool to convert sequence logo back to PWM is needed to scan a TFBS represented in logo format in a publication where the PWM is not provided or hard to be acquired. A major difficulty in developing such tool to convert sequence logo to PWM is to deal with the diversity of sequence logo images. We propose logo2PWM for reconstructing PWM from a large variety of sequence logo images. Evaluation results on over one thousand logos from three sources of different logo format show that the correlation between the reconstructed PWMs and the original PWMs are constantly high, where median correlation is greater than 0.97. Because of the high recognition accuracy, the easiness of usage, and, the availability of both web-based service and stand-alone application, we believe that logo2PWM can readily benefit the study of transcription by filling the gap between sequence logo and PWM.

  11. Dynamic Sliding Mode Evolution PWM Controller for a Novel High-Gain Interleaved DC-DC Converter in PV System

    Directory of Open Access Journals (Sweden)

    Taizhou Bei

    2014-01-01

    Full Text Available Considering the disadvantages of the traditional high-gain DC-DC converter such as big size, high voltage stress of switches, and large input current ripple, a novel high-gain interleaved boost converter with coupled-inductor and switched-capacitor was proposed correspondingly and the operation principle together with the steady-state analysis of this converter was also described. Besides, a new control approach-dynamic sliding mode evolution PWM controller (DSME PWM for the novel topological converter based on both dynamic evolution and sliding mode control was also presented. From the simulation results and experimental validation the proposed converter can fulfill high-gain boost, low ripple of both the input current and the output voltage. Furthermore, MPPT technique can be also achieved in a short time by simulation. The efficiency and stability of the converter proposed in this paper can be improved.

  12. A New parallel Resonant DC-Link Inverter for Soft Switched PWM

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J G; Kim, H S; Cho, G H [Korea Advanced Energy Research Inst., Daeduk-Danji (Korea, Republic of). Korea Nuclear Safety Center

    1993-03-01

    A novel soft switching PWM converter for high frequency AC/DC power conversion is presented by using a new parallel resonant dc-link(PRDCL) and by adopting single phase soft switching(SPSS) technique. The new PRDCL provides variable link pulse position as well as variable link pulse width, which is quite different feature from the other resonant dc-links and thus the PWM capability can be remarkably increased. The SPSS technique is also adopted for further enhancement of PWM capability. Moderate combination of two soft switching operations enables the conventional space vector PWM technique to be used. Due to distinctive advantages including true PWM capability, minimum device voltage stresses(all Vs) and reasonable additional device count(3 devices), the proposed converter can be operated in a wide power range(20-200 KW). Operational principles, analyses and the realization of a space vector PWM of the proposed converter are presented. Simulation results are also shown to verify the operational principle. (author). 15 refs., 14 figs.

  13. Elimination of output voltage oscillations in DC-DC converter using PWM with PI controller

    Directory of Open Access Journals (Sweden)

    Sreenivasappa Veeranna Bhupasandra

    2010-01-01

    Full Text Available In this paper the SIMULINK model of a PWM controlled DC-DC converter is modeled using switching function concept to control the speed of the DC motor. The presence of the voltage oscillation cycles due to higher switching frequency in the DC-DC converter is identified. The effect of these oscillations on the output voltage of the converter, Armature current, Developed torque and Speed of the DC motor is analyzed. In order to minimize the oscillation cycles the PI controller is proposed in the PWM controller.

  14. A Review on Direct Power Control for Applications to Grid Connected PWM Converters

    Directory of Open Access Journals (Sweden)

    T. A. Trivedi

    2015-08-01

    Full Text Available The Direct Power Control strategy has become popular as an alternative to the conventional vector oriented control strategy for grid connected PWM converters. In this paper, Direct Power Control as applied to various applications of grid connected converters is reviewed. The Direct Power Control for PWM rectifiers, Grid Connected DC/AC inverters applications such as renewable energy sources interface, Active Power Filters, Doubly Fed Induction Generators and AC-DC-AC converters are discussed. Control strategies such as Look-Up table based control, predictive control, Virtual Flux DPC, Model based DPC and DPC-Space Vector Modulation are critically reviewed. The effects of various key parameters such as selection of switching vector, sampling time, hysteresis band and grid interfacing on performance of direct power controlled converters are presented.

  15. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  16. Zero-Voltage Switching PWM Strategy Based Capacitor Current-Balancing Control for Half-Bridge Three-Level DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2018-01-01

    The current imbalance among the two input capacitors is one of the important issues of the half-bridge threelevel (HBTL) DC/DC converter, which would affect system performance and reliability. In this paper, a zero-voltage switching (ZVS) pulse-wide modulation (PWM) strategy including two operation...

  17. The harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter.

    OpenAIRE

    ПАНЧЕНКО, В В

    2015-01-01

    The author investigates a rectifier unit constructed on the basis of cascade connection of the main non-controlled m-pulse rectifier and PWM voltage booster converter. The research presents the analysis of the harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter on completely controlled keys. The dependence of the relative harmonic amplitude on the commutation corner is defined. The estimation of a rectifier unit electromagnetic compatibility wit...

  18. New PWM method and commutation strategy for HF-link converters for fuel cells and photovoltaics

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a new PWM method and commutation strategy for HF-link converters, which leads to safe commutation of the load current in the output bidirectional bridge. The proposed implementation is independent of the particular HF-link converter topology and bidirectional switch selection ...

  19. Atmel Microcontroller Based Soft Switched PWM ZVS Full Bridge DC to DC Converter

    Directory of Open Access Journals (Sweden)

    DEEPAK KUMAR NAYAK

    2010-12-01

    Full Text Available This paper deals with the simulation and implementation of soft switched PWM ZVS full bridge DC to DC converter. The 48V DC is efficiently reduced to 12V DC using a DC to DC converter. This converter has advantages like reduced switching losses, stresses and EMI. Input DC is converted into high frequency AC and it is stepped down to 12V level. Later it is rectified using a full wave rectifier. Laboratory model of microcontroller based DC to DC converter is fabricated and tested. The experimental results are compared with the simulation results.

  20. Interleaved Boost-Half-Bridge Dual–Input DC-DC Converter with a PWM plus Phase-Shift Control for Fuel Cell Applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    This paper presents an isolated dual-input DC-DC converter with a PWM plus phase-shift control for fuel cell hybrid energy systems. The power switches are controlled by phase shifted PWM signals with a variable duty cycle, and thus the two input voltages as well as the output voltage can...

  1. Windowed SHE-PWM of Interleaved Four-Quadrant Converters for Resonance Suppression in Traction Power Supply Systems

    DEFF Research Database (Denmark)

    Song, Kejian; Konstantinou, Georgios; Mingli, Wu

    2017-01-01

    AC electric locomotives that use a number of interleaved four-quadrant converters generate high-frequency switching harmonics which may stimulate certain resonances in traction power supply systems (TPSSs). A windowed selective harmonic elimination pulse-width modulation (SHE-PWM) method...

  2. A new power supply regulated PWM-ZCS supplied in current: analysis, project and experiments; Uma nova fonte chaveada PWM-ZCS alimentada em corrente: analise, projeto e experimentacao

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Peter Mantovanelli

    1993-10-01

    This work introduces a new power supply by PWM, operating at constant frequency, with soft communication. The new topology uses only two active switches and absorbs the transformer leakage inductance. Besides, the soft communication takes place with no conduction loss penalty, in comparison with conventional hard switch PWM converters. Principle of operation, analysis, design and experimentation results taken from laboratory prototype rated at 400 W/48 v, 40 Khz, using IGBT are presented. (author) 10 refs., 71 figs.

  3. Transistorized PWM inverter-induction motor drive system

    Science.gov (United States)

    Peak, S. C.; Plunkett, A. B.

    1982-01-01

    This paper describes the development of a transistorized PWM inverter-induction motor traction drive system. A vehicle performance analysis was performed to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of inverter and motor specifications. The inverter was a transistorized three-phase bridge using General Electric power Darlington transistors. The description of the design and development of this inverter is the principal object of this paper. The high-speed induction motor is a design which is optimized for use with an inverter power source. The primary feedback control is a torque angle control with voltage and torque outer loop controls. A current-controlled PWM technique is used to control the motor voltage. The drive has a constant torque output with PWM operation to base motor speed and a constant horsepower output with square wave operation to maximum speed. The drive system was dynamometer tested and the results are presented.

  4. Pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2008-01-01

    This book studies switch-mode power supplies (SMPS) in great detail. This type of converter changes an unregulated DC voltage into a high-frequency pulse-width modulated (PWM) voltage controlled by varying the duty cycle, then changes the PWM AC voltage to a regulated DC voltage at a high efficiency by rectification and filtering. Used to supply electronic circuits, this converter saves energy and space in the overall system. With concept-orientated explanations, this book offers state-of-the-art SMPS technology and promotes an understanding of the principle operations of PWM converters,

  5. A Novel Soft-Switching Synchronous Buck Converter for Portable Applications

    Directory of Open Access Journals (Sweden)

    Anup Kumar Panda

    2008-01-01

    Full Text Available This paper proposes a zero-voltage-transition (ZVT pulse-width-modulated (PWM synchronous buck converter, which is designed to operate at low voltage and high efficiency typically required for portable systems. A new passive auxiliary circuit that allows the main switch to operate with zero-voltage switching has been incorporated in the conventional PWM synchronous buck converter. The operation principles and a detailed steady-state analysis of the ZVT-PWM synchronous converter implemented with the auxiliary circuit are presented. Besides, the main switch and all of the semiconductor devices operate under soft-switching conditions. Thus, the auxiliary circuit provides a larger overall efficiency. The feasibility of the auxiliary circuit is confirmed by simulation and experimental results.

  6. Advanced Control Strategy of Back-to-Back PWM Converters in PMSG Wind Power System

    Directory of Open Access Journals (Sweden)

    Tan Luong Van

    2015-01-01

    Full Text Available This paper proposes a control scheme of back-to-back PWM converters for the permanent magnet synchronous generator (PMSG wind turbine system. The DC-link voltage can be controlled at the machine-side converter (MSC, while the grid-side converter (GSC controls the grid active power for a maximum power point tracking (MPPT. At the grid fault condition, the DC-link voltage controller is designed using a feedback linearization (FL theory. For the MPPT, a proportional control loop is added to the torque control to reduce the influence of the inertia moment in the wind turbines, which can improve its dynamic performance. The validity of this control algorithm has been verified by the simulation of the 2-MW PMSG wind turbine system.

  7. A single-phase PWM controlled AC to DC converter based on control of unity displacement power factor

    OpenAIRE

    Funabiki, Shigeyuki

    1990-01-01

    A modified pulse-width modulation (PWM) technique that improves the displacement power factor and the input power factor of a single-phase AC to DC converter is discussed. The modified converter is shown to have a high input power factor and allows the of DC voltage from zero to more than the maximum value of the source voltage. The displacement power factor is unity, and the input power factor is almost unity in the wide range of current command

  8. A Dual-Bridge LLC Resonant Converter with Fixed-Frequency PWM Control for Wide Input Applications

    DEFF Research Database (Denmark)

    Xiaofeng, Sun; Li, Xiaohua; Shen, Yanfeng

    2017-01-01

    This paper proposes a dual-bridge (DB) LLC resonant converter for wide input applications. The topology is an integration of a half-bridge (HB) LLC circuit and a full-bridge (FB) LLC circuit. The fixed-frequency PWM control is employed and a range of twice the minimum input voltage can be covered....... Compared with the traditional pulse frequency modulation (PFM) controlled HB/FB LLC resonant converter, the voltage gain range is independent of the quality factor and the magnetizing inductor has little influence on the voltage gain, which can simplify the parameter selection process and benefit...

  9. Power Electronic Transformer based Three-Phase PWM AC Drives

    Science.gov (United States)

    Basu, Kaushik

    A Transformer is used to provide galvanic isolation and to connect systems at different voltage levels. It is one of the largest and most expensive component in most of the high voltage and high power systems. Its size is inversely proportional to the operating frequency. The central idea behind a power electronic transformer (PET) also known as solid state transformer is to reduce the size of the transformer by increasing the frequency. Power electronic converters are used to change the frequency of operation. Steady reduction in the cost of the semiconductor switches and the advent of advanced magnetic materials with very low loss density and high saturation flux density implies economic viability and feasibility of a design with high power density. Application of PET is in generation of power from renewable energy sources, especially wind and solar. Other important application include grid tied inverters, UPS e.t.c. In this thesis non-resonant, single stage, bi-directional PET is considered. The main objective of this converter is to generate adjustable speed and magnitude pulse width modulated (PWM) ac waveforms from an ac or dc grid with a high frequency ac link. The windings of a high frequency transformer contains leakage inductance. Any switching transition of the power electronic converter connecting the inductive load and the transformer requires commutation of leakage energy. Commutation by passive means results in power loss, decrease in the frequency of operation, distortion in the output voltage waveform, reduction in reliability and power density. In this work a source based partially loss-less commutation of leakage energy has been proposed. This technique also results in partial soft-switching. A series of converters with novel PWM strategies have been proposed to minimize the frequency of leakage inductance commutation. These PETs achieve most of the important features of modern PWM ac drives including 1) Input power factor correction, 2) Common

  10. EMC Increasing of PWM Rectifier in Comparison with Classical Rectifier

    Directory of Open Access Journals (Sweden)

    R. Dolecek

    2008-12-01

    Full Text Available Pulse width modulated rectifier is a very popular topic nowadays. The modern industrial production demands continuous and lossless conversion of electrical energy parameters. This need leads to wide spread of power semiconductor converters. The rapid development in power electronics and microprocessor technology enables to apply sophisticated control methods that eliminate negative side effects of the power converters on the supply network. The phase controlled thyristor rectifiers overload the supply network with higher harmonics and reactive power consumption. That is why the PWM rectifier is being examined. In comparison with the phase controlled rectifier it can be controlled to consume nearly sinusoidal current with power factor equal to unity. Another advantage is its capability of energy recuperation. The PWM rectifier can assert itself for its good behavior in many applications, for example as an input rectifier in indirect frequency converter, or in traction. Traction vehicles equipped with PWM rectifier do not consume reactive power, do not load the supply network with higher harmonics, and the recuperation is possible. The paper deals with the PWM rectifier functional model realization and examination. Electromagnetic compatibility of PWM rectifier and classical phase controlled rectifier is compared on the basis of the input current harmonic analysis.

  11. Development of an On-Line Self-Tuning FPGA-PID-PWM Control Algorithm Design for DC-DC Buck Converter in Mobile Applications

    Directory of Open Access Journals (Sweden)

    Ahmed Sabah Al-Araji

    2017-08-01

    Full Text Available This paper presents a new development of an on-line hybrid self-tuning control algorithm of the Field Programmable Gate Array - Proportional Integral Derivative - Pulse Width Modulation (FPGA-PID-PWM controller for DC-DC buck converter which is used in battery operation of mobile applications. The main goal in this work is to propose structure of the hybrid Bees-PSO tuning control algorithm which has a capability of quickly and precisely searching in the global regions in order to obtain optimal gain parameters for the proposed controller to generate the best voltage control action to achieve the desired performance of the Buck converter output. Matlab simulation results and Xilinx development tool Integrated Software Environment (ISE experimental work show the robustness and effectiveness of the proposed on-line hybrid Bees-PSO tuning control algorithm in terms of obtaining smooth and unsaturated state voltage control action and minimizing the tracking voltage error of the Buck converter output. Moreover, the fitness evaluation number is reduced.

  12. Modeling and the analysis of control logic for a digital PWM controller based on a nano electronic single electron transistor

    Directory of Open Access Journals (Sweden)

    Rathnakannan Kailasam

    2008-01-01

    Full Text Available This paper describes the modelling and the analysis of control logic for a Nano-Device- based PWM controller. A comprehensive simple SPICE schematic model for Single Electron transistor has been proposed. The operation of basic Single Electron Transistor logic gates and SET flip flops were successfully designed and their performances analyzed. The proposed design for realizing the logic gates and flip-flops is used in constructing the PWM controller utilized for switching the buck converter circuit. The output of the converter circuit is compared with reference voltage, and when the error voltage and the reference are matched the latch is reset so as to generate the PWM signal. Due to the simplicity and accuracy of the compact model, the simulation time and speed are much faster, which makes it potentially applicable in large-scale circuit simulation. This study confirms that the SET-based PWM controller is small in size, consumes ultra low power and operates at high speeds without compromising any performance. In addition these devices are capable of measuring charges of extremely high sensitivity.

  13. Neural network based PWM AC chopper fed induction motor drive

    Directory of Open Access Journals (Sweden)

    Venkatesan Jamuna

    2009-01-01

    Full Text Available In this paper, a new Simulink model for a neural network controlled PWM AC chopper fed single phase induction motor is proposed. Closed loop speed control is achieved using a neural network controller. To maintain a constant fluid flow with a variation in pressure head, drives like fan and pump are operated with closed loop speed control. The need to improve the quality and reliability of the drive circuit has increased because of the growing demand for improving the performance of motor drives. With the increased availability of MOSFET's and IGBT's, PWM converters can be used efficiently in low and medium power applications. From the simulation studies, it is seen that the PWM AC chopper has a better harmonic spectrum and lesser copper loss than the Phase controlled AC chopper. It is observed that the drive system with the proposed model produces better dynamic performance, reduced overshoot and fast transient response. .

  14. A Harmonic Resonance Suppression Strategy for a High-Speed Railway Traction Power Supply System with a SHE-PWM Four-Quadrant Converter Based on Active-Set Secondary Optimization

    Directory of Open Access Journals (Sweden)

    Runze Zhang

    2017-10-01

    Full Text Available Pulse width modulation (PWM technology is widely used in traction converters for high-speed railways. The harmonic distribution caused by PWM is quite extensive, and increases the possibility of grid–train coupling resonance in the traction power supply system (TPSS. This paper first analyzes the mechanism of resonance, when the characteristic harmonic frequency of a four-quadrant converter (4QC current that injects into the traction grid matches the resonant frequency of the traction grid, which may result in resonance in the system. To suppress resonance, this paper adopts specific harmonic elimination–pulse width modulation (SHE-PWM technology combined with a transient direct current control strategy to eliminate the harmonics in the resonant frequency, which may suppress the grid–train coupling resonance. Due to the fact that the SHE-PWM process with multiple switching angles contains complex transcendental equations, the initial value is difficult to provide, and is difficult to solve using ordinary iterative algorithms. In this paper, an active-set secondary optimization method is used to solve the equation. The algorithm has the benefits of low dependence on initial values, fast convergence and high solution accuracy. Finally, the feasibility of the resonant suppression algorithm is verified by means of Matlab simulation.

  15. Harmonic Analyzing of the Double PWM Converter in DFIG Based on Mathematical Model

    Directory of Open Access Journals (Sweden)

    Jing Liu

    2017-12-01

    Full Text Available Harmonic pollution of double fed induction generators (DFIGs has become a vital concern for its undesirable effects on power quality issues of wind generation systems and grid-connected system, and the double pulse width modulation (PWMconverter is one of the main harmonic sources in DFIGs. Thus the harmonic analysis of the converter in DFIGs is a necessary step to evaluate their harmonic pollution of DFIGs. This paper proposes a detailed harmonic modeling method to discuss the main harmonic components in a converter. In general the harmonic modeling could be divided into the low-order harmonic part (up to 30th order and the high-order harmonic part (greater than order 30 parts in general. The low-order harmonics are produced by the circuit topology and control algorithm, and the harmonic component will be different if the control strategy changes. The high-order harmonics are produced by the modulation of the switching function to the dc variable. In this paper, the low-order harmonic modeling is established according to the directions of power flow under the vector control (VC, and the high-order harmonic modeling is established by the switching function of space vector PWM and dc currents. Meanwhile, the simulations of harmonic a components in a converter are accomplished in a real time digital simulation system. The results indicate that the proposed modeling could effectively show the harmonics distribution of the converter in DFIGs.

  16. Assessment of an Average Controller for a DC/DC Converter via Either a PWM or a Sigma-Delta-Modulator

    Directory of Open Access Journals (Sweden)

    R. Silva-Ortigoza

    2014-01-01

    Full Text Available Sliding mode control is a discontinuous control technique that is, by its nature, appropriate for controlling variable structure systems, such as the switch regulated systems employed in power electronics. However, when designing control laws based on the average models of these systems a modulator is necessary for their experimental implementation. Among the most widely used modulators in power electronics are the pulse width modulation (PWM and, more recently, the sigma-delta-modulator (Σ-Δ-modulator. Based on the importance of achieving an appropriate implementation of average control laws and the relevance of the trajectory tracking task in DC/DC power converters, for the first time, this research presents the assessment of the experimental results obtained when one of these controllers is implemented through either a PWM or a Σ-Δ-modulator to perform such a task. A comparative assessment based on the integral square error (ISE index shows that, at frequencies with similar efficiency, the Σ-Δ-modulator provides a better tracking performance for the DC/DC Buck converter. In this paper, an average control based on differential flatness was used to perform the experiments. It is worth mentioning that a different trajectory tracking controller could have been selected for this research.

  17. Laboratory manual for pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2015-01-01

    Designed to complement a range of power electronics study resources, this unique lab manual helps students to gain a deep understanding of the operation, modeling, analysis, design, and performance of pulse-width modulated (PWM) DC-DC power converters.  Exercises focus on three essential areas of power electronics: open-loop power stages; small-signal modeling, design of feedback loops and PWM DC-DC converter control schemes; and semiconductor devices such as silicon, silicon carbide and gallium nitride. Meeting the standards required by industrial employers, the lab manual combines program

  18. A study of DC-DC converters with MCT's for arcjet power supplies

    Science.gov (United States)

    Stuart, Thomas A.

    1994-01-01

    Many arcjet DC power supplies use PWM full bridge converters with large arrays of parallel FET's. This report investigates an alternative supply using a variable frequency series resonant converter with small arrays of parallel MCT's (metal oxide semiconductor controlled thyristors). The reasons for this approach are to: increase reliability by reducing the number of switching devices; and decrease the surface mounting area of the switching arrays. The variable frequency series resonant approach is used because the relatively slow switching speed of the MCT precludes the use of PWM. The 10 kW converter operated satisfactorily with an efficiency of over 91 percent. Test results indicate this efficiency could be increased further by additional optimization of the series resonant inductor.

  19. Three-phase Resonant DC-link Converter

    DEFF Research Database (Denmark)

    Munk-Nielsen, Stig

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source...... Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this procedure increased dv/dt and the size of the input/output filters of the PWM-SVI must be increased...

  20. Operational limits of a three level neutral point clamped converter used for controlling a hybrid energy storage system

    International Nuclear Information System (INIS)

    Etxeberria, A.; Vechiu, I.; Camblong, H.; Kreckelbergh, S.; Bacha, S.

    2014-01-01

    Highlights: • The control of a hybrid storage system using a Three Level NPC converter is analysed. • A sinusoidal PWM with an offset injection is used to control the storage system. • The operation of the selected converter is analysed in its entire operation range. • The operational limits of the Three Level NPC converter are defined. - Abstract: This work analyses the use of a Three-Level Neutral Point Clamped (3LNPC) converter to control the power flow of a Hybrid Energy Storage System (HESS) and at the same time interconnect it with the common AC bus of a microgrid. Nowadays there is not any storage technology capable of offering a high energy storage capacity, a high power capacity and a fast response at the same time. Therefore, the necessity of hybridising more than one storage technology is a widely accepted idea in order to satisfy the mentioned requirements. This work shows how the operational limits of the 3LNPC converter can be calculated and integrated in a control structure to facilitate an optimal use of the HESS according to the rules fixed by the user

  1. State-Trajectory Analysis and Control of LLC Resonant Converters

    OpenAIRE

    Feng, Weiyi

    2013-01-01

    With the fast development of communication systems, computers and consumer electronics, the power supplies for telecoms, servers, desktops, laptops, flat-panel TVs, LED lighting, etc. are required for more power delivery with smaller spaces. The LLC resonant converter has been widely adopted for these applications due to the advantages in high efficiency, high power density and holdup time operation capability.However, unlike PWM converters, the control of the LLC resonant converter is much m...

  2. An improved soft switched PWM interleaved boost AC-DC converter

    International Nuclear Information System (INIS)

    Genc, Naci; Iskender, Ires

    2011-01-01

    In this paper, an improved soft switched two cell interleaved boost AC/DC converter with high power factor is proposed and investigated. A new auxiliary circuit is designed and added to two cell interleaved boost converter to reduce the switching losses. The proposed auxiliary circuit is implemented using only one auxiliary switch and a minimum number of passive components without an important increase in the cost and complexity of the converter. The main advantage of this auxiliary circuit is that it not only provides zero-voltage-transition (ZVT) for the main switches but also provides soft switching for the auxiliary switch and diodes. Though all semiconductor devices operate under soft switching, they do not have any additional voltage and current stresses. The proposed converter operates successfully in soft switching operation mode for a wide range of input voltage level and the load. In addition, it has advantages such as fewer structure complications, lower cost and ease of control. In the study, the transition modes for describing the behavior of the proposed converter in one switching period are described. A prototype with 600 W output power, 50 kHz/cell switching frequency, input line voltage of 110-220 V rms and an output voltage of 400 V dc has been implemented. Analysis, design and the control circuitry are also presented in the paper.

  3. Synchronous Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede; Bose, Bimal K.

    2002-01-01

    A novel method of direct synchronous pulsewidth modulation (PWM) is applied for control of modular multilevel converters consisting from three standard triphase inverter modules along with an 0.33 p.u. output transformer. The proposed method provides synchronisation of the voltage waveforms...... for each module and the composed voltage at the output of the converter. Multilevel output voltage of the converter has quarter-wave symmetry during the whole range including the zone of overmodulation. Both continuous and discontinuous versions of synchronous PWM, based on vector approach...

  4. A new Zero-Current-Transition PWM switching cell

    Energy Technology Data Exchange (ETDEWEB)

    Grigore, V. [Electronics and Telecommunications Faculty, `Politechnica` University Bucharest (Romania); Kyyrae, J. [Helsinki University of Technology, Otaniemi (Finland): Institute of Intelligent Power Electronics

    1997-12-31

    In this paper a new Zero-Current-Transition (ZCT) PWM switching cell is presented. The proposed switching cell is composed of the normal hard-switched PWM cell (consisting of one active switch and one passive switch), plus as auxiliary circuit. The auxiliary circuit is inactive during the ON ad OFF intervals of the switches in the normal PWM switch. The transitions between the two states are controlled by the auxiliary circuit. Prior to turn-off, the current through the active switch in the PWM cell is forced to zero, thus the turn-off losses of the active switch are practically eliminated. At turn-on the auxiliary circuit slows down the growing rate of the current through the main switch. Thus, turn-on losses are also very much reduced. The active switch operates under ZCT conditions, the passive switch (diode) has a controlled reverse recovery, while the switch in the auxiliary circuit operates under Zero-Current-Switching (ZCS) conditions. (orig.) 3 refs.

  5. Led spectral and power characteristics under hybrid PWM/AM dimming strategy

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2010-01-01

    In order to dim LEDs the pulse width modulation (PWM) or amplitude modulation (AM) dimming scheme is typically used. Previous studies show that these dimming schemes can have opposite effects on diodes peak wavelength shift. An experimental study was conducted to test the behavior of InGaN diodes...... and phosphor-converted white diodes under hybrid PWM/AM modulation. Feed forward control schemes that provide stable peak wavelength position during dimming and the ability to compensate the thermally induced color shifts and the decrease of the luminous flux are investigated....

  6. A Three-level 4 x 3 Conventinal Matrix Converter

    DEFF Research Database (Denmark)

    Rong, Runjie; Loh, Poh Chiang; Wang, Peter

    2007-01-01

    This paper proposes a topology of a three-level 4 × 3 conventional matrix converter with 12 bi-directional switches. PWM control and modulation index compensation have been investigated. Operation theory has been verified by the simulation results using Matlab. The simulation results show...

  7. A new Zero-Voltage-Transition PWM switching cell

    Energy Technology Data Exchange (ETDEWEB)

    Grigore, V. [Electronics and Telecommunications Faculty `Politebuica` University Bucharest (Romania); Kyyrae, J. [Helsinki University of Technology, Otaniemi (Finland): Institute of Intelligent Power Electronics

    1997-12-31

    In this paper a new Zero-Voltage-Transition (ZVT) PWM switching cell is presented. The proposed switching cell is composed of the normal hard-switched PWM cell (consisting of one active switch and one passive switch), plus an auxiliary circuit (consisting of one active switch and some reactive components). The auxiliary circuit is inactive during the ON and OFF intervals of the switches in the normal PWM switch. However, the transitions between the two states are controlled by the auxiliary circuit. Prior to turn-on, the voltage across the active switch in the PWM cell is forced to zero, thus the turn-on losses of the active switch are practically eliminated. At turn-off the auxiliary circuit behaves like a non-dissipative passive snubber reducing the turn-off losses to a great extent. Zero-Voltage-Transition switching technique almost eliminates switching losses. The active switch operates under ZVT conditions, the passive switch (diode) has a controlled reverse recovery, and the switch in the auxiliary circuit operates under Zero-Current-Switching (ZCS) conditions. (orig.) 6 refs.

  8. A nonlinear adaptive backstepping approach applied to a three phase PWM AC-DC converter feeding induction heating

    Science.gov (United States)

    Hadri-Hamida, A.; Allag, A.; Hammoudi, M. Y.; Mimoune, S. M.; Zerouali, S.; Ayad, M. Y.; Becherif, M.; Miliani, E.; Miraoui, A.

    2009-04-01

    This paper presents a new control strategy for a three phase PWM converter, which consists of applying an adaptive nonlinear control. The input-output feedback linearization approach is based on the exact cancellation of the nonlinearity, for this reason, this technique is not efficient, because system parameters can vary. First a nonlinear system modelling is derived with state variables of the input current and the output voltage by using power balance of the input and output, the nonlinear adaptive backstepping control can compensate the nonlinearities in the nominal system and the uncertainties. Simulation results are obtained using Matlab/Simulink. These results show how the adaptive backstepping law updates the system parameters and provide an efficient control design both for tracking and regulation in order to improve the power factor.

  9. Design of a High Performance Green-Mode PWM Controller IC with Smart Sensing Protection Circuits

    Directory of Open Access Journals (Sweden)

    Shen-Li Chen

    2014-08-01

    Full Text Available A design of high performance green-mode pulse-width-modulation (PWM controller IC with smart sensing protection circuits for the application of lithium-ion battery charger (1.52 V ~ 7.5 V is investigated in this paper. The protection circuits architecture of this system mainly bases on the lithium battery function and does for the system design standard of control circuit. In this work, the PWM controller will be with an automatic load sensing and judges the system operated in the operating mode or in the standby mode. Therefore, it reduces system’s power dissipation effectively and achieves the saving power target. In the same time, many protection sensing circuits such as: (1 over current protection (OCP and under current protection (UCP, (2 over voltage protection (OVP and under voltage protection (UVP, (3 loading determintion and short circuit protection (SCP, (4 over temperature protection (OTP, (5 VDD surge-spiking protection are included. Then, it has the characteristics of an effective monitoring the output loading and the harm prevention as a battery charging. Eventually, this green-mode pulse-width-modulation (PWM controller IC will be that the operation voltage is 3.3 V, the operation frequency is 0.98 MHz, and the output current range is from 454 mA to 500 mA. Meanwhile, the output convert efficiency is range from 74.8 % to 91 %, the power dissipation efficiency in green-mode is 25 %, and the operation temperature range is between -20 0C ~ 114 0C.

  10. A new soft switched push pull current fed converter for fuel cell applications

    International Nuclear Information System (INIS)

    Delshad, Majid; Farzanehfard, Hosein

    2011-01-01

    In this paper a new zero voltage switching current fed push pull dc-dc converter is proposed for fuel cell generation system. The auxiliary circuit in this converter, not only absorbs the voltage surge across the switches at turn off instance, but also provides zero voltage switching condition for all converter switches. Therefore, the converter efficiency is increased and size and weight of the converter can be decreased. Also implementation of control circuit is very simple since the converter is PWM controlled. In this paper, the proposed dc-dc converter operating modes are analyzed and to verify the converter operation a laboratory prototype is implemented and the experimental results are presented.

  11. Bi-directional power control system for voltage converter

    Science.gov (United States)

    Garrigan, Neil Richard; King, Robert Dean; Schwartz, James Edward

    1999-01-01

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

  12. Research on Parallel Three Phase PWM Converters base on RTDS

    Science.gov (United States)

    Xia, Yan; Zou, Jianxiao; Li, Kai; Liu, Jingbo; Tian, Jun

    2018-01-01

    Converters parallel operation can increase capacity of the system, but it may lead to potential zero-sequence circulating current, so the control of circulating current was an important goal in the design of parallel inverters. In this paper, the Real Time Digital Simulator (RTDS) is used to model the converters parallel system in real time and study the circulating current restraining. The equivalent model of two parallel converters and zero-sequence circulating current(ZSCC) were established and analyzed, then a strategy using variable zero vector control was proposed to suppress the circulating current. For two parallel modular converters, hardware-in-the-loop(HIL) study based on RTDS and practical experiment were implemented, results prove that the proposed control strategy is feasible and effective.

  13. Power Quality Control and Design of Power Converter for Variable-Speed Wind Energy Conversion System with Permanent-Magnet Synchronous Generator

    Directory of Open Access Journals (Sweden)

    Yüksel Oğuz

    2013-01-01

    Full Text Available The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.

  14. Power quality control and design of power converter for variable-speed wind energy conversion system with permanent-magnet synchronous generator.

    Science.gov (United States)

    Oğuz, Yüksel; Güney, İrfan; Çalık, Hüseyin

    2013-01-01

    The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS) operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.

  15. Design of High-Voltage Switch-Mode Power Amplifier Based on Digital-Controlled Hybrid Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Yanbin Hou

    2016-01-01

    Full Text Available Compared with conventional Class-A, Class-B, and Class-AB amplifiers, Class-D amplifier, also known as switching amplifier, employs pulse width modulation (PWM technology and solid-state switching devices, capable of achieving much higher efficiency. However, PWM-based switching amplifier is usually designed for low-voltage application, offering a maximum output voltage of several hundred Volts. Therefore, a step-up transformer is indispensably adopted in PWM-based Class-D amplifier to produce high-voltage output. In this paper, a switching amplifier without step-up transformer is developed based on digital pulse step modulation (PSM and hybrid multilevel converter. Under the control of input signal, cascaded power converters with separate DC sources operate in PSM switch mode to directly generate high-voltage and high-power output. The relevant topological structure, operating principle, and design scheme are introduced. Finally, a prototype system is built, which can provide power up to 1400 Watts and peak voltage up to ±1700 Volts. And the performance, including efficiency, linearity, and distortion, is evaluated by experimental tests.

  16. An Algebraic Method of Synchronous Pulsewidth Modulation for Converters for Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    This paper describes the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of the output voltage of converters, based on one-stage closed-form strategy of PWM with pure algebraic control dependencies. It is applied to voltage source inverters with a contin......This paper describes the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of the output voltage of converters, based on one-stage closed-form strategy of PWM with pure algebraic control dependencies. It is applied to voltage source inverters...... with a continuous scheme of conventional voltage space vector modulation and with two basic variants of symmetrical discontinuous PWM. Simulations give the behaviour of the proposed method and show the advantage of algebraic synchronous PWM compared with the typical asynchronous, for low indices of the frequency...

  17. Two phase interleaved buck converter for driving high power LEDs

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2011-01-01

    The goal of this paper is to evaluate an interleaved buck topology for driving high current light-emitting diodes. Low output capacitor value allows the use of non-electrolytic capacitors extending the lifetime of the converter. Converter is operated as a constant, regulated current source which...... increases luminous efficacy of LED compared to PWM dimmed system. Because of the low dynamic resistance of LEDs the duty cycle of the converter does not change greatly with controlled current. By setting the input voltage of the buck converter to around twice the voltage of diode strings, converter can...

  18. Triphase Cascaded Converters with Direct Synchronous Pulswidth Modulation

    DEFF Research Database (Denmark)

    Oleschuk, V.; Blaabjerg, Frede; Bose, B. K.

    2002-01-01

    A novel method of direct synchronous pulse-width modulation (PWM) is applied for control of modular multilevel converters consisting from three standard triphase inverter modules along with an 0.33 p.u. output transformer. The proposed method provides synchronisation of the voltage waveforms...... for both each module and the composed voltage at the output of the converter. Multilevel output voltage of the converter has quarter-wave symmetry during the whole range including the zone of overmodulation. Both continuous and discontinuous versions of synchronous PWM, based on a vector approach...

  19. GENETIC ALGORITHM BASED SOLUTION IN PWM CONVERTER SWITCHING FOR VOLTAGE SOURCE INVERTER FEEDING AN INDUCTION MOTOR DRIVE

    Directory of Open Access Journals (Sweden)

    V. Jegathesan

    2017-11-01

    Full Text Available This paper presents an efficient and reliable Genetic Algorithm based solution for Selective Harmonic Elimination (SHE switching pattern. This method eliminates considerable amount of lower order line voltage harmonics in Pulse Width Modulation (PWM inverter. Determination of pulse pattern for the elimination of some lower order harmonics of a PWM inverter necessitates solving a system of nonlinear transcendental equations. Genetic Algorithm is used to solve nonlinear transcendental equations for PWM-SHE. Many methods are available to eliminate the higher order harmonics and it can be easily removed. But the greatest challenge is to eliminate the lower order harmonics and this is successfully achieved using Genetic Algorithm without using Dual transformer. Simulations using MATLABTM and Powersim with experimental results are carried out to validate the solution. The experimental results show that the harmonics up to 13th were totally eliminated.

  20. A novel five-level optimized carrier multilevel PWM quad-inverter six-phase AC drive

    DEFF Research Database (Denmark)

    Sanjeevikumar, P.; Blaabjerg, F.; Wheeler, Pat

    2016-01-01

    A novel single carrier pulse-width modulation (PWM) for a new quad-inverter configuration for multilevel six-phase asymmetrical open-winding ac converter is proposed in this article. Modularity of the circuit consist of four standard two-level voltage source inverters (VSIs) with slight modificat......A novel single carrier pulse-width modulation (PWM) for a new quad-inverter configuration for multilevel six-phase asymmetrical open-winding ac converter is proposed in this article. Modularity of the circuit consist of four standard two-level voltage source inverters (VSIs) with slight...... modifications, i.e. one additional bi-direction switch (MOSFET/IGBT) in each phase and a link to neutral with two capacitors to generate increased output levels. Furthermore, original optimal single carrier zero-shifted five-level modulation (SCZSFM) algorithm is developed for each VSI to behave as equivalent...

  1. EMC Specific Problems of Frequency Converters Used at Interlocking Device

    Directory of Open Access Journals (Sweden)

    J. Novak

    2009-12-01

    Full Text Available The paper deals with problems of electromagnetic compatibility (EMC of frequency control drive of electromotive switch actuator of railway switch. The frequency converter with Pulse Width Modulation (PWM and the output sinus filter are used for feeding of the asynchronous motor of the switch actuator. This drive is operated in an insulated system of feeding voltages. The drive is fed by a frequency converter with an unshielded cable with length up to 1.2 km. The EMC problems occurring at development and operating of the drive are analyzed in this paper. The used solution of these problems and experience with EMC of the given system from real operation are described in this paper as well.

  2. Bi-Frequency Modulated Quasi-Resonant Converters: Theory and Applications

    Science.gov (United States)

    Zhang, Yuefeng

    1995-01-01

    To avoid the variable frequency operation of quasi -resonant converters, many soft-switching PWM converters have been proposed, all of them require an auxiliary switch, which will increase the cost and complexity of the power supply system. In this thesis, a new kind of technique for quasi -resonant converters has been proposed, which is called the bi-frequency modulation technique. By operating the quasi-resonant converters at two switching frequencies, this technique enables quasi-resonant converters to achieve the soft-switching, at fixed switching frequencies, without an auxiliary switch. The steady-state analysis of four commonly used quasi-resonant converters, namely, ZVS buck, ZCS buck, ZVS boost, and ZCS boost converter has been presented. Using the concepts of equivalent sources, equivalent sinks, and resonant tank, the large signal models of these four quasi -resonant converters were developed. Based on these models, the steady-state control characteristics of BFM ZVS buck, BFM ZCS buck, BFM ZVS boost, and BFM ZCS boost converter have been derived. The functional block and design consideration of the bi-frequency controller were presented, and one of the implementations of the bi-frequency controller was given. A complete design example has been presented. Both computer simulations and experimental results have verified that the bi-frequency modulated quasi-resonant converters can achieve soft-switching, at fixed switching frequencies, without an auxiliary switch. One of the application of bi-frequency modulation technique is for EMI reduction. The basic principle of using BFM technique for EMI reduction was introduced. Based on the spectral analysis, the EMI performances of the PWM, variable-frequency, and bi-frequency modulated control signals was evaluated, and the BFM control signals show the lowest EMI emission. The bi-frequency modulated technique has also been applied to the power factor correction. A BFM zero -current switching boost converter has

  3. Large Signal Model of a Four-quadrant AC to DC Converter for Accelerator Magnets

    CERN Document Server

    De la Calle, R; Rinaldi, L; Völker, F V

    2001-01-01

    This paper presents the large signal model of a four-quadrant AC to DC converter, which is expected to be used in the area of particle accelerators. The system’s first stage is composed of a three-phase boost PWM (Pulse Width Modulated) rectifier with DSP (Digital Signal Processing) based power factor correction (PFC) and output voltage regulation. The second stage is a full-bridge PWM inverter that allows fast four-quadrant operation. The structure is fully reversible, and an additional resistance (brake chopper) is not needed to dissipate the energy when the beam deflection magnet acts as generator.

  4. Loss Distribution Analysis of Three-Level Active Neutral-Point-Clamped (3L-ANPC) Converter with Different PWM Strategies

    DEFF Research Database (Denmark)

    Zhang, Gang; Yang, Yongheng; Iannuzzo, Francesco

    2016-01-01

    The three-level (3L) Active Neutral-Point-Clamped (ANPC) topology has been introduced to resolve the uneven loss distribution issue in the classical 3L Neutral-Point-Clamped (NPC) topology. This Pulse-Width-Modulation (PWM) strategy is then an important means to fully explore the potential benefits...... are separated in order to improve the loss distribution among the power devices. A comparison between the proposed strategy and other major PWM strategies for the loss distribution is also carried out in this paper. Benchmarking results show that the proposed strategy has effective and superior performance...

  5. Decentralized Interleaving of Paralleled Dc-Dc Buck Converters: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rodriguez, Miguel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sinha, Mohit [University of Minnesota; Dhople, Sairaj [University of Minnesota; Poon, Jason [University of California at Berkeley

    2017-09-01

    We present a decentralized control strategy that yields switch interleaving among parallel connected dc-dc buck converters without communication. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work represents the first fully decentralized strategy for switch interleaving of paralleled dc-dc buck converters.

  6. A comprehensive study and analysis of second order harmonic ripple in DC microgrid feeding single phase PWM inverter loads

    DEFF Research Database (Denmark)

    Gautam, Aditya R.; Fulwani, Deepak; Guerrero, Josep M.

    2016-01-01

    The paper presents a detailed analysis of second order harmonic ripple in a DC microgrid. A boost converter feeding PWM inverter load is considered and equivalent circuit is proposed. The effect of the size of input capacitor, output capacitor and inductor of boost converter, on this ripple has...

  7. Three-phase Resonant DC-link Converter

    OpenAIRE

    Munk-Nielsen, Stig

    1997-01-01

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this pro...

  8. Electromagnetic phenomena analysis in brushless DC motor with speed control using PWM method

    Science.gov (United States)

    Ciurys, Marek Pawel

    2017-12-01

    Field-circuit model of a brushless DC motor with speed control using PWM method was developed. Waveforms of electrical and mechanical quantities of the designed motor with a high pressure vane pump built in a rotor of the motor were computed. Analysis of electromagnetic phenomena in the system: single phase AC network - converter - BLDC motor was carried out.

  9. Transformer-assisted PWM zero-voltage switching pole inverter with high output bandwidth applied to linear motor drives

    NARCIS (Netherlands)

    Myrzik, J.M.A.; Duarte, J.L.; Haardt, de P.; Vissers, J.

    2002-01-01

    An application of the transformer-assisted PWM zero-voltage switching pole inverter (TRAP) is described in this paper. The TRAP is based on the auxiliary resonant commutated pole inverter (ARCP), but avoids its disadvantages. This paper describes the converter functionality and its applicability

  10. Performance optimization of a photovoltaic chain conversion by the PWM control

    Science.gov (United States)

    Rezoug, M. R.; Chenni, R.

    2017-02-01

    The interest of the research technique of maximum power point tracking, exposed by this article, lays in the fact of work instantly on the real characteristic of the photovoltaic module. This work is based on instantaneous measurements of its terminals' current & voltage as well as the exploitation of the characteristic "Power - Duty Cycle" to define rapidly the Duty cycle in which power reaches its maximum value. To ensure instantaneous tracking of the point of maximum power, we use "DC/DC Converter" based on "Pulse Wave Modulation's (PWM) Command" controlled by an algorithm implanted in a microcontroller's memory. This algorithm responds to the quick changes in climate (sunlight and temperature). To identify the control parameters "VPV & IPV" at any change in operating conditions, sensors are projected. this algorithm applied to the Duty cycle of the static converter enables the control of power supplied by the photovoltaic generator thanks to oscillatory movement around the MPP. Our article highlights the importance of this technique which lays in its simplicity and performance in changing climatic conditions. This efficiency is confirmed by experimental tests and this technique will improve its predecessors.

  11. New three-phase ac-ac converter incorporating three-phase boost integrated ZVT bridge and single-phase HF link

    International Nuclear Information System (INIS)

    Abdelhamid, Tamer H.; Sabzali, Ahmad J.

    2008-01-01

    This paper presents a new zero voltage transition (ZVT), power factor corrected three phase ac-ac converter with single phase high frequency (HF) link. It is a two stage converter; the first stage is a boost integrated bridge converter (combination of a 3 ph boost converter and a bridge converter) operated at fixed frequency and that operates in two modes at ZVT for all switches and establishes a 1 ph square wave HF link. The second stage is a bi-directional pulse width modulation (PWM) 3 ph bridge that converts the 1 ph HF link to a 3 ph voltage using a novel switching strategy. The converter modes of operation and key equations are outlined. Simulation of the overall system is conducted using Simulink. The switching strategy and its corresponding control circuit are clearly described. Experimental verification of the simulation is conducted for a prototype of 100 V, 500 W at 10 kHz link frequency

  12. Transistor Clamped Five-Level Inverter using Non-Inverting Double Reference Single Carrier PWM Technique for photovoltaic applications

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar; Fedák, Viliam

    2017-01-01

    in output waveform. Under-modulation (modulation Index = 0.85), unity (modulation Index =1) and over-modulation (modulation Index = 1.25) PWM signal is obtained to drive control switches. Simulation results will confirm the functionality, design and operation of the proposed MLI and NIDRSC PWM Technique....

  13. Digital simulation of FM-ZCS-quasi resonant converter fed DD servo drive using Matlab Simulink

    Directory of Open Access Journals (Sweden)

    Kattamuri Narasimha Rao

    2009-01-01

    Full Text Available This paper deals with digital simulation of FM-ZCS-quasi resonant converter fed DC servo drive using Matlab Simulink. Quasi Resonant Converter (QRC is fast replacing conventional PWM converters in high frequency operation. The salient feature of QRC is that the switching devices can be either switched on at zero voltage or switched off at zero current, so that switching losses are zero ideally. Switching stresses are low, volumes are low and power density is high. This property imparts high efficiency and high power density to the converters. The output of QRC is regulated by varying the switching frequency of the converter. Hence it is called Frequency modulated Zero current/zero voltage switching quasi resonant converter. The present work deals with simulation of DC Servo motor fed from ZCS-QRC using Matlab. Simulation results show that the ZCS-QRC's have low total harmonic distortion. The ZCS-QRC operating in half wave and full wave modes are simulated successfully. .

  14. Soft switching bidirectional DC-DC converter for ultracapacitor-batteries interface

    International Nuclear Information System (INIS)

    Adib, Ehsan; Farzanehfard, Hosein

    2009-01-01

    In this paper a new soft switching bidirectional DC-DC converter is introduced which can be applied as the interface circuit between ultracapacitors and batteries or fuel cells. All semiconductor devices in the proposed converter are soft switched while the control circuit remains PWM. Due to achieved soft switching condition, the energy conversion through the proposed converter is highly efficient. The proposed converter is analyzed and a prototype converter is implemented. The presented experimental results confirm the theoretical analysis.

  15. Distortion-Free 1-Bit PWM Coding for Digital Audio Signals

    Directory of Open Access Journals (Sweden)

    John Mourjopoulos

    2007-01-01

    Full Text Available Although uniformly sampled pulse width modulation (UPWM represents a very efficient digital audio coding scheme for digital-to-analog conversion and full-digital amplification, it suffers from strong harmonic distortions, as opposed to benign non-harmonic artifacts present in analog PWM (naturally sampled PWM, NPWM. Complete elimination of these distortions usually requires excessive oversampling of the source PCM audio signal, which results to impractical realizations of digital PWM systems. In this paper, a description of digital PWM distortion generation mechanism is given and a novel principle for their minimization is proposed, based on a process having some similarity to the dithering principle employed in multibit signal quantization. This conditioning signal is termed “jither” and it can be applied either in the PCM amplitude or the PWM time domain. It is shown that the proposed method achieves significant decrement of the harmonic distortions, rendering digital PWM performance equivalent to that of source PCM audio, for mild oversampling (e.g., ×4 resulting to typical PWM clock rates of 90 MHz.

  16. Distortion-Free 1-Bit PWM Coding for Digital Audio Signals

    Directory of Open Access Journals (Sweden)

    Mourjopoulos John

    2007-01-01

    Full Text Available Although uniformly sampled pulse width modulation (UPWM represents a very efficient digital audio coding scheme for digital-to-analog conversion and full-digital amplification, it suffers from strong harmonic distortions, as opposed to benign non-harmonic artifacts present in analog PWM (naturally sampled PWM, NPWM. Complete elimination of these distortions usually requires excessive oversampling of the source PCM audio signal, which results to impractical realizations of digital PWM systems. In this paper, a description of digital PWM distortion generation mechanism is given and a novel principle for their minimization is proposed, based on a process having some similarity to the dithering principle employed in multibit signal quantization. This conditioning signal is termed "jither" and it can be applied either in the PCM amplitude or the PWM time domain. It is shown that the proposed method achieves significant decrement of the harmonic distortions, rendering digital PWM performance equivalent to that of source PCM audio, for mild oversampling (e.g., resulting to typical PWM clock rates of 90 MHz.

  17. Soft switching bidirectional DC-DC converter for ultracapacitor-batteries interface

    Energy Technology Data Exchange (ETDEWEB)

    Adib, Ehsan; Farzanehfard, Hosein [Dept. of Electrical and Computer Engineering, Isfahan Univ. of Technology (Iran)

    2009-12-15

    In this paper a new soft switching bidirectional DC-DC converter is introduced which can be applied as the interface circuit between ultracapacitors and batteries or fuel cells. All semiconductor devices in the proposed converter are soft switched while the control circuit remains PWM. Due to achieved soft switching condition, the energy conversion through the proposed converter is highly efficient. The proposed converter is analyzed and a prototype converter is implemented. The presented experimental results confirm the theoretical analysis. (author)

  18. Analisis Harmonisa Inverter PWM Satu Fasa

    OpenAIRE

    Rejeki Simanjorang

    2008-01-01

    Pada tesis ini dianalisis harmonisa inverter PWM satu fasa. Inverter PWM satu fasa yang akan ditinjau adalah inverter satu fasa jembatan penuh (konvensional) dan inverter komposit. Analisis difokuskan pada penentuan pola penyaklaran yang optimum agar pembangkitan harmonisa dan switching losses inverter rendah. Untuk menentukan pola penyaklaran optimum maka dilakukan analisis yang berbasis pada rangkaian ekivalen harmonisa inverter satu fasa. Dengan menggunakan pola penyaklaran optimum, kedua ...

  19. The Study of Operation Modes and Control Strategies of a Multidirectional MC for Battery Based System

    Directory of Open Access Journals (Sweden)

    Saman Toosi

    2015-01-01

    Full Text Available To enhance the performance of stand-alone battery based system and to achieve the continuous power transmission, the behavior of multidirectional matrix converter (MDMC has been analyzed in different operation modes. A systematic method interfacing a renewable source, a storage battery, and a load is proposed for a stand-alone battery based power system (SABBPS to utilize the MDMC as PWM converter, inverter, or PWM converter and inverter in different operation modes. In this study, the Extended Direct Duty Pulse Width Modulation (EDDPWM technique has been applied to control the power flow path between the renewable source, load, and the battery. Corresponding to generator voltage, input frequency, and loads demands, several operating states and control strategies are possible. Therefore, the boundaries and distribution of operation modes are discussed and illustrated to improve the system performance. The mathematical equation of the EDDPWM under different operation modes has been derived to achieve the maximum voltage ratio in each mode. The theoretical and modulation concepts presented have been verified in simulation using MATLAB and experimental testing. Moreover, the THD, ripple, and power flow direction have been analyzed for output current to investigate the behavior of system in each operation mode.

  20. Effect of 60Co γ-rays on PWM and LPS induced lymphocytes

    International Nuclear Information System (INIS)

    Su Liaoyuan; Liu Keliang; Liu Fenju

    1987-01-01

    The relationship between lymphocytes induced by PWM (pokeweed mitogen) and LPS (lipopolysaccharide) was investigated by means of 3 H-TdR incorporation. The study showed that, in vitro, PWM-induced cells were able to promote the stimulating effect of LPS to B lymphocytes. The stimulating effect of PWM-induced cells was obviously weakened after PWM cells being irradiated with γ-rays. When PWM-induced cells and LPS-induced cells were incubated together, with one kind of cells exposed to 60 Co γ-ray, incorporation value of 3 H-TdR became much smaller and the synergetic function disappeared, especially, when PWM-induced cells were irradiated. For patients suffering from carcinoma of nasopharynx, while treated with 60 Co γ-rays, the incorporation value in LPS-induced cells approached normal level, meanwhile, the incorporation value in PEM-induced cells reduced significantly and the stimulating effect of PWM-induced cells on LPS-induced cells became much weaker. The facts described above demonstrated that PWM-induced cells have the function of T-helper cells and play more important role in the synergy than LPS-induced cells

  1. Progressive decrement PWM algorithm for minimum mean square error inverter output voltage

    International Nuclear Information System (INIS)

    Ghaeb, J.A.; Smadi, M.A.; Ababneh, M.

    2011-01-01

    Highlights: → The main contribution of this work is to provide a better performance for the power inverter operation. → The proposed technique splits the determined original pulse-width of an inverter operation in to many pulses. → The new approach extends the central pulse and shrinks the exterior pulses. → This is leading to an inverter output cycle close to the sinusoidal form of fewer harmonics. - Abstract: The paper proposes two modulation techniques for the power inverter. These new techniques are named progressive decrement PWM algorithm (PDPA) and progressive increment PWM algorithm (PIPA). Both techniques take the determined original pulse-width of an inverter operation and split it to many pulses. In the PDPA technique, the largest width is given to the middle pulse and the width of the boundary pulses is reduced progressively starting from the first boundary-pulse toward the last boundary-pulse. In the PIPA technique, there is a gradual increment instead of decrement. The two techniques have been proved that it can maintain the original pulse-width of the inverter operation. The new approach PDPA extends the central pulse and shrinks the exterior pulses, leading to an inverter output cycle close to the sinusoidal form of fewer harmonic contents. Simulation results are performed to evaluate the performances of the proposed techniques: PDPA and PIPA and to compare them with the well known methods. The main contribution of the proposed PDPA technique is that it provides a better performance for the most harmonic orders compared to the well established sinusoidal PWM technique.

  2. Three Phase Six-Switch PWM Buck Rectifier with Power Factor Improvement

    DEFF Research Database (Denmark)

    Zafar Ullah Khan, M; Mohsin Naveed, M.; Hussain, Dil Muhammad Akbar

    2013-01-01

    Conventional Phase Controlled Rectifier injects low order current harmonics into the AC mains. Large size filtering components are required to attenuate these harmonics. In this paper, Three Phase Six-Switch PWM Buck Rectifier[1] is presented which operates at nearly unity power factor and provides...

  3. Overmodulation of n-level three-leg DC-AC diode-clamped converters with comprehensive capacitor voltage balance

    DEFF Research Database (Denmark)

    Busquets-Monge, S.; Maheshwari, Ram Krishan; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories are selec......This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories...

  4. Optimal Selective Harmonic Mitigation Technique on Variable DC Link Cascaded H-Bridge Converter to Meet Power Quality Standards

    DEFF Research Database (Denmark)

    Najjar, Mohammad; Moeini, Amirhossein; Dowlatabadi, Mohammadkazem Bakhshizadeh

    2016-01-01

    In this paper, the power quality standards such as IEC 61000-3-6, IEC 61000-2-12, EN 50160, and CIGRE WG 36-05 are fulfilled for single- and three-phase medium voltage applications by using Selective Harmonic Mitigation-PWM (SHM-PWM) in a Cascaded H-Bridge (CHB) converter. Furthermore, the ER G5/...

  5. A High-Precision Control for a ZVT PWM Soft-Switching Inverter to Eliminate the Dead-Time Effect

    Directory of Open Access Journals (Sweden)

    Baoquan Kou

    2016-07-01

    Full Text Available Attributing to the advantages of high efficiency, low electromagnetic interference (EMI noise and closest to the pulse-width-modulation (PWM converter counterpart, zero-voltage-transition (ZVT PWM soft-switching inverters are very suitable for high-performance applications. However, the conventional control algorithms intended for high efficiency generally results in voltage distortion. Thus, this paper, for the first time, proposes a high-precision control method to eliminate the dead-time effect through controlling the auxiliary current in the auxiliary resonant snubber inverter (ARSI, which is a typical ZVT PWM inverter. The dead-time effect of ARSI is analyzed, which is distinguished from hard-switching inverters. The proposed high-precision control is introduced based on the investigation of dead-time effect. A prototype was developed to verify the effectiveness of the proposed control. The experimental results shows that the total harmonic distortion (THD of the output current of the ARSI can be reduced compared with that of the hard-switching inverter, because the blanking delay error is eliminated. The quality of the output current and voltage can be further improved by utilizing the proposed control method.

  6. Color adjustable LED driver design based on PWM

    Science.gov (United States)

    Du, Yiying; Yu, Caideng; Que, Longcheng; Zhou, Yun; Lv, Jian

    2012-10-01

    Light-emitting diode (LED) is a liquid cold source light source that rapidly develops in recent years. The merits of high brightness efficiency, long duration, high credibility and no pollution make it satisfy our demands for consumption and natural life, and gradually replace the traditional lamp-house-incandescent light and fluorescent light. However, because of the high cost and unstable drive circuit, the application range is restricted. To popularize the applications of the LED, we focus on improving the LED driver circuit to change this phenomenon. Basing on the traditional LED drive circuit, we adopt pre-setup constant current model and introduce pulse width modulation (PWM) control method to realize adjustable 256 level-grays display. In this paper, basing on human visual characteristics and the traditional PWM control method, we propose a new PWM control timing clock to alter the duty cycle of PWM signal to realize the simple gamma correction. Consequently, the brightness can accord with our visual characteristics.

  7. Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Krim, Fateh; Gaubert, Jean-Paul

    2009-01-01

    This paper proposes direct power control (DPC) for three-phase PWM rectifiers using a new switching table, without line voltage sensors. The instantaneous active and reactive powers, directly controlled by selecting the optimum state of the converter, are used as the PWM control variables instead of the phase line currents being used. The main goal of the control system is to maintain the dc-bus voltage at the required level, while input currents drawn from the power supply should be sinusoidal and in phase with respective phase voltages to satisfy the unity power factor (UPF) operation. Conventional PI and a designed fuzzy logic-based controller, in the dc-bus voltage control loop, have been used to provide active power command. A dSPACE based experimental system was developed to verify the validity of the proposed DPC. The steady-state, and dynamic results illustrating the operation and performance of the proposed control scheme are presented. As a result, it was confirmed that the novel DPC is much better than the classical one. Line currents very close to sinusoidal waveforms (THD < 2%) and good regulation of dc-bus voltage are achieved using PI or fuzzy controller. Moreover, fuzzy logic controller gives excellent performance in transient state, a good rejection of impact load disturbance, and a good robustness

  8. Switching power converters medium and high power

    CERN Document Server

    Neacsu, Dorin O

    2013-01-01

    An examination of all of the multidisciplinary aspects of medium- and high-power converter systems, including basic power electronics, digital control and hardware, sensors, analog preprocessing of signals, protection devices and fault management, and pulse-width-modulation (PWM) algorithms, Switching Power Converters: Medium and High Power, Second Edition discusses the actual use of industrial technology and its related subassemblies and components, covering facets of implementation otherwise overlooked by theoretical textbooks. The updated Second Edition contains many new figures, as well as

  9. Color deviations in phosphor converted high power light emitting diodes under different dimming schemes

    International Nuclear Information System (INIS)

    Ludwiczak, Bogna; Jantsch, Wolfgang

    2015-01-01

    We investigate experimentally the color stability of high power phosphor converted InGaN LEDs under pulse width modulation (PWM) and continuous current reduction (CCR) dimming modes and for varied operation temperatures. Our measurements reveal that the chromaticity coordinate pathways of the warm white and the cold white LED's differ for the same operation conditions. The color deviation- minimizing phenomenon of opposite peak wavelength shifts appears only for a cold white LED under CCR driving mode. This favorable effect does not occur for warm white LEDs. This type of LED exhibits the best color stability under PWM driving mode. The experimental results are consistently explained in terms of the quantum confined Stark effect and temperature induced changes of the LED emission. - Highlights: • Cold and warm white LEDs reacts colorimetrically unlike in different driving modes. • For cold white emission driving conditions are crucial. • Opposite peak wavelength shifts reduces color deviations for cold white emission. • For warm white emission rather phosphor properties determines color deviations

  10. Self oscillating PWM modulators, a topological comparison

    DEFF Research Database (Denmark)

    Poulsen, Søren; Andersen, Michael Andreas E.

    2004-01-01

    or fs/ð range respectively, where fs is the switching frequency of the converter. For some applications this will require unacceptable high switching frequency to achieve enough control loop bandwidth for the desired dynamic performance. With self oscillating modulators, the open loop bandwidth is equal...... to fs which makes this type of modulators an excellent choice for a wide range of applications. Self oscillating PWM modulators can be made in a number of ways, either as voltage or current mode modulators, and the self oscillating behavior can be achieved either by using hysteresis control...... or by shaping the open loop function of the modulator so its gain and phase response causes a closed loop natural oscillation. The two main types of self oscillating modulators have many similarities, but differences in dynamic performance and linearity are present. The work presented is related to the author...

  11. Realise of PWM-generating based on FPGA

    International Nuclear Information System (INIS)

    Su Rongfeng; Xu Ruinian; Huang Maomao

    2012-01-01

    The power supply digital controllers of Shanghai Synchrotron Radiation Facility(SSRF) make use of the PWM (pulse width modulation) wave as the feedback to the power-electrical devices, so as to obtain constant current of high accuracy and stability. The design of PWM wave generation structure in FPGA is good for a compact controller,and the reduction of the usage of Integrated Circuits (ICs) decreases the interference from the noise among the ICs, hence better performance of the controller. In addition, FPGA can be programmed circularly at any time,so as to optimize the structure design and make a maximum use of the advantage of FPGA. As a part of transplanting the complete function of the DSP (digital signal processor/processing), realizing the generation of PWM wave in FPGA is feasible. In this paper, we report progress in this regard at SSRF. (authors)

  12. A unified triangle carrier based PWM strategy for three-phase N-level diode clamped inverters

    DEFF Research Database (Denmark)

    Li, Kai; Xie, Chuan; Wei, Min

    2017-01-01

    The triangle carrier based pulse width modulation (TCB-PWM) can be functionally equivalent to space vector base PWM (SVB-PWM). For multi-level inverter, it is very difficult to realize the SVB-PWM because its vector space is very complex. In this paper, a unified TCB-PWM strategy for three-phase ...

  13. A Novel Application of Zero-Current-Switching Quasiresonant Buck Converter for Battery Chargers

    Directory of Open Access Journals (Sweden)

    Kuo-Kuang Chen

    2011-01-01

    Full Text Available The main purpose of this paper is to develop a novel application of a resonant switch converter for battery chargers. A zero-current-switching (ZCS converter with a quasiresonant converter (QRC was used as the main structure. The proposed ZCS dc–dc battery charger has a straightforward structure, low cost, easy control, and high efficiency. The operating principles and design procedure of the proposed charger are thoroughly analyzed. The optimal values of the resonant components are computed by applying the characteristic curve and electric functions derived from the circuit configuration. Experiments were conducted using lead-acid batteries. The optimal parameters of the resonance components were determined using the load characteristic curve diagrams. These values enable the battery charger to turn on and off at zero current, resulting in a reduction of switching losses. The results of the experiments show that when compared with the traditional pulse-width-modulation (PWM converter for a battery charger, the buck converter with a zero- current-switching quasiresonant converter can lower the temperature of the activepower switch.

  14. Pengaruh Penambahan PWM (Pulse Width Modulation Pada Generator HHO Tipe Dry Cell

    Directory of Open Access Journals (Sweden)

    Fungky Dyan Pertiwi

    2013-09-01

    Full Text Available Generator HHO memanfaatkan proses elektrolisis air agar mendapatkan gas H2. Namun, pada praktiknya pemakaian arus dari aki yang besar dan temperatur tinggi membuat bejana generator menjadi cepat rusak, sehingga dibutuhkan tambahan rangkaian elektronika PWM pada pengujian generator HHO guna mengatasi permasalahan tersebut. Penelitian menggunakan elektroda plat berjumlah 9 berdimensi 120mm 120mm, tebal 1mm dan dibatasi oleh o-ring dengan diameter 126mm, tebal 3mm. Pengujian dilakukan secara eksperimen dengan 2 kelompok yaitu kelompok control yang mana pengujian tanpa menggunakan PWM serta kelompok uji dimana pengujian menggunakan PWM dengan variasi duty cycle 30%, 50% dan 70%. Pengujian dilakukan hingga temperatur elektrolit 93oC. Hasil uji didapatkan bahwa arus, laju produksi dan efisiensi terbesar didapatkan pada pengujian tanpa PWM yang mencapai 60,6A, 6,033 10-6kg/s dan 25,69%. Namun, pada pengambilan data kedua efisiensi turun menjadi 19,74%. Penambahan PWM pada pengujian berpengaruh pada arus dan temperatur yang stabil meskipun laju produksi dan efisiensi lebih kecil daripada pengujian tanpa PWM. Pengujian dengan PWM pada duty cycle 70% menghasilkan laju produksi dan efisiensi terbesar yang mencapai 1,843 10-6 kg/s dan 15,19%.

  15. PWM CONTROLLER'S MODELS FOR INVESTIGATION ACS IN SPICEFAMILY ECAD PROGRAMS

    Directory of Open Access Journals (Sweden)

    O. V. VASYLENKO

    2018-05-01

    Full Text Available Purpose. To improve simulation and design of Automatic Control Systems in the SPICE-compatible programs and to obtain separate economic and universal macromodels of PWM controller. Development of an PWM controller economical macromodel for the study of automatic control systems (ACS in computer-aided design (ECAD  programs, which does not generate algorithmic failures in comparison with the existing models of PWM. Findings. Analysis of SPICE-family applications’ mathematical basis allowed to classifying existing models of PWM-controllers, defining their suitability for ACS simulation. The criteria for the synthesis of new models have been defined. For the SPICE 3G algorithms, the Switch and Averaged models based on behavioral elements has been developed. Universal and economical PWM controller macromodel based on the simple algorithm for determining the output signal with minimum numbers of input parameters has been designed. For the Automated Measuring magnetic susceptibility System, the macromodel of quasi-PWM signal generator have been designed, which is used in the compensation subsystem. This model is different from the existing ones: it synthesizes the staircase output signal instead the pulse one, thus, there is direct control of the amplitude of the output signal, which is taken averaged. The adequacy of the models is confirmed as comparison of the simulation results during investigations of the model already existing in the SPICE program, as well as the results of experiments with real ACS. The modeling of the PWM controller was carried out on the basis of behavioral elements from the ECAD library, simulation (solution of algebra-differential equations systems with programming elements is based on SPICE algorithms. The object of the study was the simulation process of ACS with the pulse-width principle of adjusting the output value. The subject of the research are the models of PWM controllers. Originality. The new macromodel of PWM

  16. A Reconfigurable Series Resonant DC-DC Converter for Wide-Input and Wide-Output Voltages

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Qin, Zian

    2017-01-01

    This paper proposes a dual-bridge based LC series resonant dc-dc converter. The input inverter unit incorporates two bridge structures, i.e., a full-bridge inverter and a half-bridge inverter. For the output rectifier, it can be a full-bridge rectifier or an asymmetric half-bridge rectifier....... Different from the conventional resonant converter, a fixed-frequency PWM control is employed which makes the optimization of magnetic components easier. The primary-side switches can achieve ZVS and the secondary-side diodes turn off with ZCS. In addition, the root-mean-square (RMS) values...... of the transformer currents do not significantly vary with respect to the voltage variation. Therefore, this converter can maintain high efficiency over a wide voltage range. The topology and operating principle are firstly described. Then the dc voltage gain and the RMS current characteristics are detailed. Finally...

  17. Control of a resonant d.c.-link converter for a.c. motor drives

    Directory of Open Access Journals (Sweden)

    Astrid Petterteig

    1992-10-01

    Full Text Available This paper presents the control of the resonant d.c.-link converter for a.c. motor drives. This is a low loss converter with higher efficiency than a conventional PWM converter, but it requires complex control. It needs a special control of the resonant d.c.-link voltage in addition to the discrete control of the a.c. side currents. Simulations show how the control of the a.c. currents, the modulation principle, influences the overall performance of the converter.

  18. Shunt PWM advanced var compensators based on voltage source inverters for Facts applications

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Pedro G; Misaka, Isamu; Watanabe, Edson H [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1994-12-31

    Increased attention has been given to improving power system operation. This paper presents modeling, analysis and design of reactive shunt power compensators based on PWM-Voltage Source Inverters (Pulse Width Modulation -Voltage Source Inverters). (Pulse Width Modulation - Voltage Source Inverters). The control algorithm is based on new concepts of instantaneous active and reactive power theory. The objective is to show that with a small capacitor in the side of a 3-phase PWM-VSI it is possible to synthesize a variable reactive (capacitive or inductive) device. Design procedures and experimental results are presented. The feasibility of this method was verified by digital simulations and measurements on a small scale model. (author) 9 refs., 12 figs.

  19. SYNTHESIS OF VOLTAGES OF UNIFORM PWM IN TIME REGULATION

    Directory of Open Access Journals (Sweden)

    A. G. Stryzhniou

    2014-01-01

    Full Text Available The article describes a process of synthesis and qualitative assessment of the harmonic composition of voltages of multiple and single PWM pulses in time regulation, being, along with amplitude, frequency and phase method, one of control methods of an asynchronous motor. The main point of time regulation is that a pause after any two single PWM pulses with different polarity or after any two groups of multiple PWM pulses with different polarity changes during a process of regulation. Feature of time regulation is that a motor has fast response in the range of small-signal of control and good linearity of speed-torque characteristics in the whole control range. Analytical expressions of parameters of PWM pulses ai and ti are obtained which allow to simplify considerably a process of formation and implementation of time regulation using tabular or indexed-tabular methods. These expressions allow not only to define voltage amplitude of  harmonic but also to perform qualitative assessment of harmonic composition of output voltages at time regulation. It is specified that harmonic frequencies wi = w0/q change in inverse proportion to magnitude of parameter q during a process of regulation and there is a replacement of a fundamental frequency by frequencies of higher harmonics.The offered approach allows to synthesize voltage of uniform single and multiple PWM pulses and to perform their comparative and qualitative analysis and the obtained expressions can be used at modeling of AC motor work. Voltage of multiple PWM pulses which is formed using stepped reference voltage with even quantity of steps in a half period and a pause on a zero level has the best parameters by criterion of a minimum of harmonic components and a maximum of a factor of anharmonicity Kнс at time regulation.

  20. A soft switching with reduced voltage stress ZVT-PWM full-bridge converter

    Science.gov (United States)

    Sahin, Yakup; Ting, Naim Suleyman; Acar, Fatih

    2018-04-01

    This paper introduces a novel active snubber cell for soft switching pulse width modulation DC-DC converters. In the proposed converter, the main switch is turned on under zero voltage transition and turned off under zero voltage switching (ZVS). The auxiliary switch is turned on under zero current switching (ZCS) and turned off under zero current transition. The main diode is turned on under ZVS and turned off under ZCS. All of the other semiconductors in the converter are turned on and off with soft switching. There is no extra voltage stress on the semiconductor devices. Besides, the proposed converter has simple structure and ease of control due to common ground. The detailed theoretical analysis of the proposed converter is presented and also verified with both simulation and experimental study at 100 kHz switching frequency and 600 W output power. Furthermore, the efficiency of the proposed converter is 95.7% at nominal power.

  1. Analysis of Input and Output Ripples of PWM AC Choppers

    Directory of Open Access Journals (Sweden)

    Pekik Argo Dahono

    2008-11-01

    Full Text Available This paper presents an analysis of input and output ripples of PWM AC choppers. Expressions of input and output current and voltage ripples of single-phase PWM AC choppers are first derived. The derived expressions are then extended to three-phase PWM AC choppers. As input current and output voltage ripples specification alone cannot be used to determine the unique values of inductance and capacitance of the LC filters, an additional criterion based on the minimum reactive power is proposed. Experimental results are included in this paper to show the validity of the proposed analysis method.

  2. A digital input class-D audio amplifier with sixth-order PWM

    International Nuclear Information System (INIS)

    Luo Shumeng; Li Dongmei

    2013-01-01

    A digital input class-D audio amplifier with a sixth-order pulse-width modulation (PWM) modulator is presented. This modulator moves the PWM generator into the closed sigma—delta modulator loop. The noise and distortions generated at the PWM generator module are suppressed by the high gain of the forward loop of the sigma—delta modulator. Therefore, at the output of the modulator, a very clean PWM signal is acquired for driving the power stage of the class-D amplifier. A sixth-order modulator is designed to balance the performance and the system clock speed. Fabricated in standard 0.18 μm CMOS technology, this class-D amplifier achieves 110 dB dynamic range, 100 dB signal-to-noise rate, and 0.0056% total harmonic distortion plus noise. (semiconductor integrated circuits)

  3. Model Predictive Control of Power Converters for Robust and Fast Operation of AC Microgrids

    DEFF Research Database (Denmark)

    Dragicevic, Tomislav

    2018-01-01

    the load power at the same time. Those functionalities are conventionally achieved by hierarchical linear control loops. However, they have limited transient response and high sensitivity to parameter variations. This paper aims to mitigate these problems by firstly introducing an improvement of the FCS......This paper proposes the application of a finite control set model predictive control (FCS-MPC) strategy in standalone ac microgrids (MGs). AC MGs are usually built from two or more voltage source converters (VSCs) which can regulate the voltage at the point of common coupling, while sharing......-MPC strategy for a single VSC based on tracking of derivative of the voltage reference trajectory. Using only a single step prediction horizon, the proposed strategy exhibits low computational expense but provides steady state performance comparable to PWM, while its transient response and robustness...

  4. Analysis, Design, Modeling, and Control of an Interleaved-Boost Full-Bridge Three-Port Converter for Hybrid Renewable Energy Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Zhang, Zhe; Knott, Arnold

    2017-01-01

    This paper presents the design, modeling, and control of an isolated dc-dc three-port converter (TPC) based on an interleaved-boost full-bridge converter with pulsewidth modulation (PWM) and phase-shift control for hybrid renewable energy systems. In the proposed topology, the switches are driven...

  5. Feedforward Synchronised PWM for Adjustable Speed AC Drives with Different Control Modes

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede; Jensen, Flemming Buus

    2002-01-01

    This paper presents a novel method of direct synchronised pulswidth modulation (PWM) for three-phase voltage source inverters, feeding induction motors with different control regimes. It is based on the universal algorithm with either simplified algebraic or accurate trigonometric control functions......, with vector approached for determination of the pulse patterns, with vector approach for determination of the pulse patterns. Different control modes of the drive system with synchronised PWM, including standard scalar V/F control, and also V2/F = constant and V/F2 = constant control regimes, have been...... analysed in the paper. Simulations give the behaviour of the PWM techniques proposed. Both continuous and discontinuous schemes of synchronised PWM, applied for the corresponding control regime, have been analysed and compared....

  6. Prediction of power losses in silicon iron sheets under PWM voltage supply

    International Nuclear Information System (INIS)

    Amar, M.; Kaczmarek, R.; Protat, F.

    1994-01-01

    The behavior of iron losses in silicon iron steels submitted to a PWM voltage is studied. The influence of modulation parameters (the depth of modulation and the number of eliminated harmonics) is clarified. In particular, the idea of an equivalent alternating pulse voltage that gives the same iron losses as the PWM voltage is established. An estimation formula for iron losses under the PWM voltage is developed based on the loss separation model and the voltage form factor. ((orig.))

  7. Boosted PWM open loop control of hydraulic proportional valves

    International Nuclear Information System (INIS)

    Amirante, R.; Innone, A.; Catalano, L.A.

    2008-01-01

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots

  8. Boosted PWM open loop control of hydraulic proportional valves

    Energy Technology Data Exchange (ETDEWEB)

    Amirante, R.; Catalano, L.A. [Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Via Re David 200, 70125 Bari (Italy); Innone, A. [Universita degli Studi di Foggia, via Napoli, 25 Foggia (Italy)

    2008-08-15

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots. (author)

  9. High flexibility and low cost digital implementation for modern PWM strategies

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Kerekes, Tamas

    2011-01-01

    like AZSPWM, NSPWM, or ACRPWM. By using a conventional PWM unit from a microcontroller, these modern modulation techniques are often difficult, or even impossible, to implement. The proposed method can be used to implement PWM strategies even for those microcontrollers which are not equipped...

  10. Analog Fixed Maximum Power Point Control for a PWM Step-downConverter for Water Pumping Installations

    DEFF Research Database (Denmark)

    Beltran, H.; Perez, E.; Chen, Zhe

    2009-01-01

    This paper describes a Fixed Maximum Power Point analog control used in a step-down Pulse Width Modulated power converter. The DC/DC converter drives a DC motor used in small water pumping installations, without any electric storage device. The power supply is provided by PV panels working around....... The proposed Optimal Power Point fix voltage control system is analyzed in comparison to other complex controls....... their maximum power point, with a fixed operating voltage value. The control circuit implementation is not only simple and cheap, but also robust and reliable. System protections and adjustments are also proposed. Simulations and hardware are reported in the paper for a 150W water pumping application system...

  11. A Zero-Voltage Switching Control Strategy for Dual Half-Bridge Cascaded Three-Level DC/DC Converter with Balanced Capacitor Voltages

    DEFF Research Database (Denmark)

    Liu, Dong; Wang, Yanbo; Chen, Zhe

    2017-01-01

    The input capacitor's voltages are unbalanced under the conventional control strategy in a dual half-bridge cascaded three-level (TL) DC/DC converter, which would affect the high voltage stresses on the capacitors. This paper proposes a pulse-wide modulation (PWM) strategy with two working modes...... for the dual half-bridge cascaded TL DC/DC converter, which can realize the zero-voltage switching (ZVS). More significantly, a capacitor voltage balance control is proposed by alternating the two working modes of the proposed ZVS PWM strategy, which can eliminate the voltage unbalance on the four input...... capacitors. Therefore, the proposed control strategy can improve the converter's performances in: 1) reducing the switching losses and noises of the power switches; and 2) reducing the voltage stresses on the input capacitors. Finally, the simulation results are conducted to verify the proposed control...

  12. A PWM strategy for acoustic noise reduction for grid-connected single-phase inverters

    Energy Technology Data Exchange (ETDEWEB)

    Shao, R.; Guo, Z.; Chang, L. [New Brunswick Univ., Fredericton, NB (Canada). Dept. of Electrical and Computer Engineering

    2006-07-01

    This paper presented a newly proposed and improved pulse width modulation (PWM) strategy for grid-connected single-phase inverters. Small distributed generators using energy from renewable resources such as PV and wind systems typically use grid-connected single-phase inverters as voltage source inverters for good acoustic performance. PWM is generally applied in these inverters in order to achieve good waveforms of output current as required by interconnection standards. In routine simultaneous switching PWM methods, the current ripples through the inverter output filter inductor are at the carrier switching frequency, which is one of the major causes for inverter acoustic noise. The new PWM strategy effectively alleviates acoustic noise and improves output power quality. It is based on the principle of evenly splitting the switching of Insulated Gate Bipolar Transistors (IGBT) in each switching cycle among all IGBTs of the full bridge, thereby using a non-simultaneous mode of PWM which doubles the output current ripple frequency. This increases the inductor current ripple frequency to twice the carrier frequency. It is therefore possible to increase the current ripple frequency, or noise frequency into the range of ultrasonic which is inaudible to the human ear, without increasing the inverter's switching frequency to which the inverter's switching loss is proportional. In addition, this new PWM scheme can reduce the output current harmonics distortion and dc link current ripples. As such, lower capacitance in dc link capacitors and lower inductance of output inductor are needed. The improved PWM scheme was verified in a 3 kW grid-connected single-phase inverter. It was shown that the PWM strategy can be readily implemented with a digital signal processing microcontroller. 8 refs., 11 figs.

  13. Liquid Nitrogen Temperature Operation of a Switching Power Converter

    Science.gov (United States)

    Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.

    1995-01-01

    The performance of a 42/28 V, 175 W, 50 kHz pulse-width modulated buck dc/dc switching power converter at liquid nitrogen temperature (LNT) is compared with room temperature operation. The power circuit as well as the control circuit of the converter, designed with commercially available components, were operated at LNT and resulted in a slight improvement in converter efficiency. The improvement in power MOSFET operation was offset by deteriorating performance of the output diode rectifier at LNT. Performance of the converter could be further improved at low temperatures by using only power MOSFET's as switches. The use of a resonant topology will further improve the circuit performance by reducing the switching noise and loss.

  14. Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Gaubert, Jean-Paul; Krim, Fateh

    2010-01-01

    This paper is concerned with the design and implementation of current control of three-phase PWM rectifier based on predictive control strategy. The proposed predictive current control technique operates with constant switching frequency, using space-vector modulation (SVM). The main goal of the designed current control scheme is to maintain the dc-bus voltage at the required level and to achieve the unity power factor (UPF) operation of the converter. For this purpose, two predictive current control algorithms, in the sense of deadbeat control, are developed for direct controlling input current vector of the converter in the stationary α-β and rotating d-q reference frame, respectively. For both predictive current control algorithms, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of both tracking errors of current vector components at the end of the switching period, is computed and applied during a predefined switching period by means of SVM. The main advantages of the proposed predictive current control are that no need to use hysteresis comparators or PI controllers in current control loops, and constant switching frequency. Finally, the developed predictive current control algorithms were tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance in steady and transient states, and verify the validity of the proposed predictive current control which is compared to other control strategies.

  15. Position control of an electro-pneumatic system based on PWM technique and FLC.

    Science.gov (United States)

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Pulsewidth modulated DC-to-DC power conversion circuits, dynamics, and control designs

    CERN Document Server

    Choi, Byungcho

    2013-01-01

    This is the definitive reference for anyone involved in pulsewidth modulated DC-to-DC power conversion Pulsewidth Modulated DC-to-DC Power Conversion: Circuits, Dynamics, and Control Designs provides engineers, researchers, and students in the power electronics field with comprehensive and complete guidance to understanding pulsewidth modulated (PWM) DC-to-DC power converters. Presented in three parts, the book addresses the circuitry and operation of PWM DC-to-DC converters and their dynamic characteristics, along with in-depth discussions of control design of PWM DC-to

  17. Evaluation and optimization of the bandwidth of static converters: application to multi-cell converters; Evaluation et optimisation de la bande passante des convertisseurs statiques

    Energy Technology Data Exchange (ETDEWEB)

    Aime, M.

    2003-11-15

    Thanks to the technological progress achieved in the field of power electronics, the use of static converters has spread to new applications. In particular, some applications such as active filtering or the supply of special AC machines require power converters having good dynamic performances. The subject of this thesis is to evaluate systematically the dynamic performances of multi-cell converters, and then to optimize these performances. This document is organized in four chapters. The first one summarizes the main multilevel converter structures, and some control strategies dedicated to these structures. The second chapter presents the evaluation criteria chosen to quantify the dynamic performances of static converters. These criteria are then used to compare the performances obtained with two different PWM strategies. An optimized strategy which results from a trade-off between the two former strategies is then introduced. The third chapter shows a new control strategy of multi-cell voltage source converters. This new strategy enables to control the peak current at a fixed switching frequency. The operation of this controller is explained, and the results obtained by digital simulations are presented and discussed. The fourth chapter deals with the experimental achievement of the peak current control. In particular, the implementation of the control algorithm within a FPGA is demonstrated. Finally, the conclusion of this thesis presents some orientations for further developments, in order to improve the current control strategy and to widen its field of applications. (author)

  18. High-feedback Operation of Power Electronic Converters

    DEFF Research Database (Denmark)

    Zhusubaliyev, Zhanybai T.; Mosekilde, Erik; Andriyanov, Alexey I.

    2013-01-01

    The purpose of this review is to provide a survey of some of the most important bifurcation phenomena that one can observe in pulse-modulated converter systems when operating with high corrector gain factors. Like other systems with switching control, electronic converter systems belong...... to the class of piecewise-smooth dynamical systems. A characteristic feature of such systems is that the trajectory is “sewed” together from subsequent discrete parts. Moreover, the transitions between different modes of operation in response to a parameter variation are often qualitatively different from...

  19. Design and Experimentation of a Control System Implemented on Raspberry Pi 3 Board for Photovoltaic Systems Using SEPIC Converter

    Directory of Open Access Journals (Sweden)

    Mohamed Boutouba

    2017-12-01

    Full Text Available In this paper, a voltage regulation system is proposed for photovoltaic energy sources (PV, using Single-Ended Primary Inductance Converter as a DC-DC converter to feed loads working with specific input voltage. The choose of SEPIC converter is due to the output voltage ripple of developed-type converters are usually small and can be lower than 2%, also it considered as a buck and boost converter and thereafter loads with lower or higher voltage could be powered. Matlab Simulink is used as environment to develop control strategies to guaranties a stable voltage at the loads terminals. Two algorithms are used to fulfill this role: A Conventional PID and PI-Fuzzy logic controller to generate the PWM signal for the SEPIC converter. Hence, to validate the work some real-time simulations are treated by implemented the control strategies on a low-cost control board: The Raspberry Pi 3 in order to manage the operation of system and collecting the simulation data. Also, and for verification purposes, several simulations were treated to verify the good behavior of the proposed system.

  20. A dual-path, current-sensing resistor-free boost LED driver with fast PWM dimming

    International Nuclear Information System (INIS)

    Zhou Minchao; Lü Danzhu; Cheng Lin; Hong Zhiliang; Liu, Bill Yang

    2013-01-01

    A boost LED driver featuring a high PWM dimming ratio and optimized efficiency is presented. This LED driver, which has a low dropout voltage and is able to drive 3–7 LEDs in series with constant output current and fast PWM dimming, provides an alternative technique for brightness adjustment. A dual-path control scheme with automatic switching and state maintenance is proposed. Meanwhile, a cascode current mirror structure is applied with the output transistor multiplexed as an LED PWM dimming transistor. Implemented in 0.5 μm 25 V BCD process, the measurement results show that a voltage conversion range of 5 V input to 6–24 V output with constant output current is obtained. With automatically switching dual-path control and an optimized current mirror, the response time during PWM dimming is reduced to as low as 240 ns and the efficiency keeps above 89% over a wide PWM dimming ratio - 250 mA output current. (semiconductor integrated circuits)

  1. Development and optimization of a matrix converter supplying an electronic ballast - UV lamp system for water sterilization

    Science.gov (United States)

    Bokhtache, Aicha Aissa; Zegaoui, Abdallah; Aillerie, Michel; Djahbar, Abdelkader; Hemici, Kheira

    2018-05-01

    Electronic ballasts dedicated to discharge lamps allow improving the quality of radiation by operating at high frequency. In the present work, the use of a single-phase direct converter with a matrix structure for supplying a low-pressure mercury-argon UVC lamp for water sterilization is proposed. The structure of the converter is based on two switching cells allowing the realization of a fully controllable bidirectional switches. The advantages of such a matrix topology include the delivered of a sinusoidal waveform current with a controllable power factor close to unity, variable in amplitude and frequency. In order to obtain the desired amplitude and frequency, a PWM control was associated in the current realization. Finally, a linear adjustment of the lamp arc current was warranted by using of a PI regulator.

  2. New DC/DC High Step Up Isolated Converter with ZVS

    Directory of Open Access Journals (Sweden)

    Ehsan Movahedi

    2014-10-01

    Full Text Available In this paper we presents a soft switch sepic, flyback converter. At first the converter have hard switching in main switch and completely analysis then added auxiliary circuit for soft switching Auxiliary circuit in the converter is not only soft switching condition for the main switch but also prevents the spike voltage across the main switch when turned off that because leakage inductance. Therefore, the proposed converter efficiency in comparison with the previous converters increased and voltage stress on the main switch is reduced. Also the auxiliary switch in the converter have soft switching and thereby decrese losses. this converter Control with pwm.These converter have higher efficiency than the similar converters and the cost is low. Auxiliary circuit in the converter is not only soft switching condition for the main switch but also prevents the spike voltage across the main switch when turned off that because leakage inductance. Therefore, the proposed converter efficiency in comparison with the previous converters increased and voltage stress on the main switch is reduced.

  3. Application of digital control techniques for satellite medium power DC-DC converters

    Science.gov (United States)

    Skup, Konrad R.; Grudzinski, Pawel; Nowosielski, Witold; Orleanski, Piotr; Wawrzaszek, Roman

    2010-09-01

    The objective of this paper is to present a work concerning a digital control loop system for satellite medium power DC-DC converters that is done in Space Research Centre. The whole control process of a described power converter bases on a high speed digital signal processing. The paper presents a development of a FPGA digital controller for voltage mode stabilization that was implemented using VHDL. The described controllers are a classical digital PID controller and a bang-bang controller. The used converter for testing is a simple model of 5-20 W, 200 kHz buck power converter. A high resolution digital PWM approach is presented. Additionally a simple and effective solution of filtering of an analog-to-digital converter output is presented.

  4. Discrete/PWM Ballast-Resistor Controller

    Science.gov (United States)

    King, Roger J.

    1994-01-01

    Circuit offers low switching loss and automatic compensation for failure of ballast resistor. Discrete/PWM ballast-resistor controller improved shunt voltage-regulator circuit designed to supply power from high-resistance source to low-impedance bus. Provides both coarse discrete voltage levels (by switching of ballast resistors) and continuous fine control of voltage via pulse-width modulation.

  5. PV Power-Generation System with a Phase-Shift PWM Technique for High Step-Up Voltage Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-01-01

    Full Text Available A PV power-generation system with a phase-shift pulse-width modulation (PWM technique for high step-up voltage applications is proposed. The proposed power-generation system consists of two stages. In the input stage, all power switches of the full-bridge converter with phase-shift technique can be operated with zero-current switching (ZCS at turn-on or turn-off transition. Hence, the switching losses of the power switches can be reduced. Then, in the DC output stage, a voltage-doubler circuit is used to boost a high dc-link bus voltage. To supply a utility power, a dc/ac inverter is connected to induce a sinusoidal source. In order to draw a maximum power from PV arrays source, a microcontroller is incorporated with the perturbation and observation method to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In this study, a full load power of 300 W prototype has been built. Experimental results are presented to verify the performance and feasibility of the proposed PV power-generation system.

  6. High-Feedback Operation of Power Electronic Converters

    Directory of Open Access Journals (Sweden)

    Gennady Y. Mikhal'chenko

    2013-03-01

    Full Text Available The purpose of this review is to provide a survey of some of the most important bifurcation phenomena that one can observe in pulse-modulated converter systems when operating with high corrector gain factors. Like other systems with switching control, electronic converter systems belong to the class of piecewise-smooth dynamical systems. A characteristic feature of such systems is that the trajectory is “sewed” together from subsequent discrete parts. Moreover, the transitions between different modes of operation in response to a parameter variation are often qualitatively different from the bifurcations we know for smooth systems. The review starts with an introduction to the concept of border-collision bifurcations and also demonstrates the approach by which the full dynamics of the piecewise-linear, time-continuous system can be reduced to the dynamics of a piecewise-smooth map. We describe the main bifurcation structures that one observes in three different types of converter systems: (1 a DC/DC converter; (2 a multi-level DC/DC converter; and (3 a DC/AC converter. Our focus will be on the bifurcations by which the regular switching dynamics becomes unstable and is replaced by ergodic or resonant periodic dynamics on the surface of a two-dimensional torus. This transition occurs when the feedback gain is increased beyond a certain threshold, for instance in Electronics 2013, 2 114 order to improve the speed and accuracy of the output voltage regulation. For each of the three converter types, we discuss a number of additional bifurcation phenomena, including the formation and reconstruction of multi-layered tori and the appearance of phase-synchronized quasiperiodicity. Our numerical simulations are compared with experimentally observed waveforms.

  7. Energy-saving operation of a converter-fed synchronous machine

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, I.; Veszpremi, K. [Technical University of Budapest, Department of Electrical Machines and Drives, Budapest (Hungary)

    1997-12-31

    In the Converter-Fed Synchronous Machine (CFSM) there is no need for forced commutation the CL and CF converters operate with line commutation, the CM is commutated by the machine voltages. This drive is applied mainly for large power and high speed controlled drives. Considering the large power, the investigation of energy-saving operation is important. As in the DC and the induction motor drives the energy-saving operation is implemented by flux control. (orig.) 6 refs.

  8. Performance analysis of samarium cobalt P.M. synchronous motor fed from PWM inverters

    International Nuclear Information System (INIS)

    Rahman, M.A.; Choudhury, M.A.

    1985-01-01

    This paper presents an analysis and performance of samarium cobalt permanent magnet (P.M.) synchronous motors fed from two types of voltage source pulse width modulated (PWM) inverters. The analysis and test results on the steady state performance of a P.M. motor fed from PWM inverters are presented. PWM inverters are used in variable voltage variable frequency applications to avoid a double conversion process of ordinary inverters. In drives, they are used for voltage and speed regulation of motors. Use of modulation technique in inverters also allow to eliminate or minimize selected harmonics from the inverter output voltage

  9. The rotating converter GKN II starts operation

    International Nuclear Information System (INIS)

    Jergas, E.

    1989-01-01

    At the beginning of 1989 the energy supply and consumption of the 110-kV-railway mains has changed considerably with starting the rotating converter of the German Federal Railways (DB) in the joint nuclear power station Neckar GmbH (GKN) block II. A description is given of the planned utilization of the rotating converters at baseload operation and possibilities for optimal energy use are shown. (orig.) [de

  10. Multi-Output Power Converter, Operated from a Regulated Input Bus, for the Sireus Rate Sensor

    Directory of Open Access Journals (Sweden)

    Torrecilla Marcos Compadre

    2017-01-01

    Full Text Available This paper describes a DC to DC converter designed to meet the power supply requirements of the SiREUS Coarse Rate Sensor (CRS which is a 3-axis MEMS Rate Sensor (MRS that uses a resonating ring gyro and will be used in different ESA missions. The converter supplies +5V, −5V, 3.3V, 1.8V and 40V and it has been designed and prototyped by Clyde Space Ltd with the EQM and FM units being manufactured by Selex ES. The first model was designed for a 28V un-regulated bus and the second model presented here has been designed for a 50V regulated bus. PWM voltage regulation was not used because of the noise requirements and the regulated input bus allowed an unregulated power stage approach. There are also stringent volume and interface constraints, which also affected the design. For such reasons, a fixed dutycycle, quasi-resonant single-ended topology with output linear regulators has been implemented; having the advantages of providing low switching losses, low radiated and conducted noise and no over-voltage failure mode. This paper highlights the techniques used to satisfy stringent noise and protection requirements of the load.

  11. The 77 K operation of a multi-resonant power converter

    Science.gov (United States)

    Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.

    1995-01-01

    The liquid-nitrogen temperature (77 K) operation of a 55 W, 200 kHz, 48/28 V zero-voltage switching multi-resonant dc/dc converter designed with commercially available components is reported. Upon dipping the complete converter (power and control circuits) into liquid-nitrogen, the converter performance improved as compared to the room-temperature operation. The switching frequency, resonant frequency, and the characteristic impedance did not change significantly. Accordingly, the zero-voltage switching was maintained from no-load to full-load for the specified line variations. Cryoelectronics can provide high density power converters, especially for high power applications.

  12. Simple Digital Control of a Two-Stage PFC Converter Using DSPIC30F Microprocessor

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2010-01-01

    The use of dsPIC digital signal controllers (DSC) in Switch Mode Power Supply (SMPS) applications opens new perspectives for cheap and flexible digital control solutions. This paper presents the digital control of a two stage power factor corrector (PFC) converter. The PFC circuit is designed...... and built for 70W rated output power. Average current mode control for boost converter and current programmed control for forward converter are implemented on a dsPIC30F1010. Pulse Width Modulation (PWM) technique is used to drive the switching MOSFETs. Results show that digital solutions with ds...

  13. Temperature prediction in high speed bone grinding using motor PWM signal.

    Science.gov (United States)

    Tai, Bruce L; Zhang, Lihui; Wang, Anthony C; Sullivan, Stephen; Wang, Guangjun; Shih, Albert J

    2013-10-01

    This research explores the feasibility of using motor electrical feedback to estimate temperature rise during a surgical bone grinding procedure. High-speed bone grinding is often used during skull base neurosurgery to remove cranial bone and approach skull base tumors through the nasal corridor. Grinding-induced heat could propagate and potentially injure surrounding nerves and arteries, and therefore, predicting the temperature in the grinding region would benefit neurosurgeons during the operation. High-speed electric motors are controlled by pulse-width-modulation (PWM) to alter the current input and thus maintain the rotational speed. Assuming full mechanical to thermal power conversion in the grinding process, PWM can be used as feedback for heat generation and temperature prediction. In this study, the conversion model was established from experiments under a variety of grinding conditions and an inverse heat transfer method to determine heat flux. Given a constant rotational speed, the heat conversion was represented by a linear function, and could predict temperature from the experimental data with less than 20% errors. Such results support the advance of this technology for practical application. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Apparent permeability of electrical steel under PWM magnetisation

    International Nuclear Information System (INIS)

    Moses, A.J.; Leicht, J.; Anderson, P.

    2006-01-01

    In recent years much attention has been paid to material performance under pulse width modulation (PWM) excitation conditions, which is of increasing importance to motor applications particularly in energy efficient variable speed drive systems. It is well known that in general, losses increase significantly with reducing modulation index, the increase depending on parameters such as silicon contents, thickness and grain size. The effect of the PWM waveform on permeability has attracted little attention until now. So in this paper its influence on the permeability of electrical steel is analysed and characterised. A prediction approach based on the permeability under sine wave excitation and total harmonic distortion is introduced which results in errors below 10% for non-electrical steel at 1.5 T

  15. Primary Parallel Isolated Boost Converter with Bidirectional Operation

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gökhan

    2012-01-01

    This paper presents a bidirectional dc/dc converter operated with batteries both in the input and output. Primary parallel isolated boost converter (PPIBC) with transformer series connection on the high voltage side is preferred due to its ability to handle high currents in the low voltage side. ...... and output battery banks with a defined ramp....

  16. PWM pulse pattern optimization method using carrier frequency modulation. Carrier shuhasu hencho ni yoru PWM pulse pattern saitekikaho

    Energy Technology Data Exchange (ETDEWEB)

    Iwaji, Y.; Fukuda, S. (Hokkaido University, Sapporo (Japan))

    1991-07-15

    Sinusoidal inverters are getting more widely used keeping pace with the development of semiconductor switching elements. This paper discusses optimizing a PWM pulse pattern at an inverter output to drive an induction motor, proposes methods for improving distortion and torque ripples using a carrier frequency modulation (CFM), and describes a method for realizing the improvement through use of a single-chip microcomputer. The method defines evaluation parameters corresponding to the distortion and torque ripples, and optimizes the CFM depth to the parameters. The PWM pulse pattern has its voltage vector and time width so selected that the time integrated space vector of a three-phase voltage approaches a circular locus. Furthermore, the carrier frequency, that is the sampling frequency of the inverter, is also adjusted so that the above evaluation parameters are minimized. The addition of a new variable called the frequency modulation provides freedom in selecting an output characteristic as called for by the purpose. 12 refs., 18 figs.

  17. PWM control of current source type six-phase inverter with improved waveforms by coupling reactor; Ketsugo reactor ni yori hakei kaizen sareta denryugata rokuso inverter no PWM seigyo

    Energy Technology Data Exchange (ETDEWEB)

    Inami, K.; Danjo, M.; Kondo, Y.; Yamada, M. [Niihama Technical College, Ehime (Japan); Toki, K. [Shikoku Electric Power Co., Inc., Kagawa (Japan); Heike, J. [Shikoku Instrumentation Co. Ltd., Kagawa (Japan)

    1998-10-01

    A PWM method has been applied to a high capacity six phase current source inverter system in order to obtain sinusoidal output voltage and current. In this system, the three-phase coupling reactor is connected between the inverter output and an induction motor used as a load. Then the reactor eliminates harmonic components included in the inverter output current except 12k {+-} 1 (k=1,2,3)th order. As a result, the distortion factor of the inverter output current decreases. But the resonant circuit is composed of the capacitance of filter capacitor and the induction motor leakage inductance. Then the resonance current is superimposed on the induction motor phase currents. To solve this problem, the optimal PWM pattern is derived, so that the resonant current becomes very small. The order of the resonant frequency component of the induction motor phase current depend on the inverter frequency. Then total inverter frequency range is divided into several areas. The optimal PWM pattern is derived in each areas. As a result, the use of each optimal PWM pattern allows us to drive the induction motor, over a wide range of speed, under the condition of small distortion factor of phase currents. 5 refs., 10 figs., 1 tab.

  18. EVALUATION OF VARIOUS UNIPOLAR MULTICARRIER PWM STRATEGIES FOR FIVE LEVEL FLYING CAPACITOR INVERTER

    Directory of Open Access Journals (Sweden)

    B. SHANTHI

    2012-06-01

    Full Text Available This paper presents the comparison of unipolar multicarrier Pulse Width Modulation (PWM techniques for the Flying Capacitor Multi Level Inverter (FCMLI. Due to switch combination redundancies, there are certain degrees of freedom to generate the five level AC output voltage. This paper presents the use of Control Freedom Degree (CFD combination. The effectiveness of the PWM strategies developed using CFD are demonstrated by simulation and experimentation. The results indicate that the multilevel inverter triggered by the developed USHPWM strategy exhibits reduced harmonics. PWM strategies developed are implemented in real time using dSPACE/Real Time Interface (RTI. The simulation and experimental output closely match with each other validating the strategies presented.

  19. ABNORMAL AND TRANSIENT MODES OF THE CONVERTER BOOSTER TYPE FOR DC TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    Yu. P. Goncharov

    2008-12-01

    Full Text Available The results of analytical research and computer design of the anomalous, steady-state and transitional modes related to the resonance in the input filter of voltage added converter based on IGBT with the PWM are presented. The ways of resonance removal by both the control means and the power blocks, combined with the overvoltage protection, are offered.

  20. Passivity-Based Control by Series/Parallel Damping of Single-Phase PWM Voltage Source Converter

    NARCIS (Netherlands)

    del Puerto Flores, Dunstano; Scherpen, Jacqueline; Liserre, Marco; de Vries, Martijn M. J.; Kransse, Marco J.; Monopoli, Vito Giuseppe

    This paper describes a detailed design procedure for passivity-based controllers developed using the Brayton-Moser (BM) framework. Several passivity-based feedback designs are presented for the voltage-source converter, specifically for the H-bridge converter, since nowadays it is one of the

  1. Monolithic quasi-sliding-mode controller for SIDO buck converter with a self-adaptive free-wheeling current level

    Science.gov (United States)

    Xiaobo, Wu; Qing, Liu; Menglian, Zhao; Mingyang, Chen

    2013-01-01

    An analog implementation of a novel fixed-frequency quasi-sliding-mode controller for single-inductor dual-output (SIDO) buck converter in pseudo-continuous conduction mode (PCCM) with a self-adaptive freewheeling current level (SFCL) is presented. Both small and large signal variations around the operation point are considered to achieve better transient response so as to reduce the cross-regulation of this SIDO buck converter. Moreover, an internal integral loop is added to suppress the steady-state regulation error introduced by conventional PWM-based sliding mode controllers. Instead of keeping it as a constant value, the free-wheeling current level varies according to the load condition to maintain high power efficiency and less cross-regulation at the same time. To verify the feasibility of the proposed controller, an SIDO buck converter with two regulated output voltages, 1.8 V and 3.3 V, is designed and fabricated in HEJIAN 0.35 μm CMOS process. Simulation and experiment results show that the transient time of this SIDO buck converter drops to 10 μs while the cross-regulation is reduced to 0.057 mV/mA, when its first load changes from 50 to 100 mA.

  2. Operation and maintenance strategies for wave energy converters

    DEFF Research Database (Denmark)

    Ambühl, Simon; Marquis, Laurent; Kofoed, Jens Peter

    2015-01-01

    costs including costs due to lost electricity production are minimized. The risk-based approach is compared with an approach where only boats are used and another approach where the target is to minimize the downtime of the device. This article presents a dynamic approach for total operation......Inspection and maintenance costs are a significant contributor to the cost of energy for wave energy converters. There are different operation and maintenance strategies for wave energy converters. Maintenance can be performed after failure (corrective) or before a breakdown (preventive) occurs....... Furthermore, a helicopter and boats can be used to transport equipment and personnel to the device, or the whole device can be towed to a harbour for operation and maintenance actions. This article describes, among others, a risk-based inspection and maintenance planning approach where the overall repair...

  3. Grid-Forming-Mode Operation of Boost-Power-Stage Converter in PV-Generator-Interfacing Applications

    Directory of Open Access Journals (Sweden)

    Jukka Viinamäki

    2017-07-01

    Full Text Available The application of constant power control and inclusion of energy storage in grid-connected photovoltaic (PV energy systems may increase the use of two-stage system structures composed of DC–DC-converter-interfaced PV generator and grid-connected inverter connected in cascade. A typical PV-generator-interfacing DC–DC converter is a boost-power-stage converter. The renewable energy system may operate in three different operation modes—grid-forming, grid-feeding, and grid-supporting modes. In the last two operation modes, the outmost feedback loops are taken from the input terminal of the associated power electronic converters, which usually does not pose stability problems in terms of their input sources. In the grid-forming operation mode, the outmost feedback loops have to be connected to the output terminal of the associated power electronic converters, and hence the input terminal will behave as a negative incremental resistor at low frequencies. This property will limit the operation of the PV interfacing converter in either the constant voltage or constant current region of the PV generator for ensuring stable operation. The boost-power-stage converter can be applied as a voltage or current-fed converter limiting the stable operation region accordingly. The investigations of this paper show explicitly that only the voltage-fed mode would provide feasible dynamic and stability properties as a viable interfacing converter.

  4. Control Strategies for Trap Filter Interfaced Three-Phase Grid Connected Converters

    DEFF Research Database (Denmark)

    Min, Huang

    In order to utilize renewable energy systems power electronics are needed to convert the energy to grid. The AC-DC and DC-AC power conversion are dominant in wind power system and photovoltaic system. However, the use of PWM scheme introduces undesirable harmonics. In order to enhance the grid...... damping in order to stabilize the whole system with resonance issue. LC trap filter application for current source converters to reduce the size of the filter and get a higher power factor....... integration of the renewable energy systems, the filter plays an important role. Even though this topic has already been widely studied, there are many optimizations and problems should be solved. How to design a filter for grid-connected converters in distributed generation system to get a lower loss...

  5. A PWM Controller of a Full Bridge Single-Phase Synchronous Inverter for Micro-Grid System

    Science.gov (United States)

    Rahman, Tawfikur; Motakabber, S. M. A.; Ibrahimy, M. I.; Raghib, Aliza ‘Aini Binti Md Ralib@ Md

    2017-12-01

    Nowadays, microgrid system technology is becoming popular for small area power management systems. It is essential to be less harmonic-distortion and high efficiency of the inverter for microgrid applications. Pulse width modulation (PWM) controller is a conventional switching control technique which is suitable to use in the microgrid connected power inverter system. The control method and algorithm of this technique are challenging, and different approaches are required to avoid the complexity for a customized solution of the microgrid application. This paper proposes a comparative analysis of different controller and their operational methods. A PWM controller is used to reduce the ripple voltage noise while a continuous current mode provides a small output ripple which gives steady-state error as zero on fundamental and cutoff frequency. To reduce the ripple current, higher frequency harmonic distortion, switching loss and phase noise, LC low pass filter is used on either side of input and output terminals. The proposed inverter is designed by MATLAB 2016a simulation software. A balanced load resistance (RL = 20.5 Ω) of star configuration and a dual input DC voltage of ± 35V are considered. In this design, the circuit parameters, the fundamental frequency of 50 Hz, the PWM duty cycle of 95%, the cutoff frequency of the switching controller of 33 kHz are considered. The inverter in this paper exhibits THD of 0.44% and overall efficiency approximately of 98%. The proposed inverter is expected to be suitable for microgrid applications.

  6. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  7. Design Research on Three-Phase PWM Rectifier Based on Double Closed Loop Control Technology

    Directory of Open Access Journals (Sweden)

    Guang Ya LIU

    2014-02-01

    Full Text Available Based on the high frequency of three-phase voltage source PWM rectifier, this paper established a mathematical model of three phase current inner ring and outer ring voltage, and put forward the setting method of three phase double closed loop control. Finally, it was verified through simulation. The experimental results show that Three-phase output of DC voltage is stable with the operation of regulating systems, the current flowing into the grid tends to be sinusoidal and power factor is close to 1, which greatly reduce the interference of harmonics on the grid, thus improve grid operation.

  8. High benefits approach for electrical energy conversion in electric vehicles from DC to PWM-AC without any generated harmonic

    International Nuclear Information System (INIS)

    Fathabadi, Hassan

    2014-01-01

    Highlights: • Novel hybrid power source including AC feature for using in electric/hybrid vehicles. • Minimizing the energy loss in electric/hybrid vehicles by using the proposed system. • Suitable AC wave form for braking/accelerating purposes in electric/hybrid vehicles. • A novelty is that the harmonic generated by the added AC feature is really zero. • Another novelty is the capability of choosing arbitrary frequency for AC feature. - Abstract: This paper presents a novel hybrid power source, including a Li-ion battery together with an interface, which generates simultaneously electrical energy with the forms of both DC and AC for electric vehicles. A novel and high benefits approach is applied to convert the electrical energy of the Li-ion battery from DC form to single-phase symmetric pulse-width modulation (PWM)-AC form. Harmonic generation is one of the important problems when electrical energy is converted from DC to AC but there are not any generated harmonic during the DC/AC conversion using the proposed technique. The proposed system will be widely used in electric/hybrid vehicles because it has many benefits. Minimizing the energy loss (saving energy), no generated harmonic (it is really zero), the capability of arbitrary/necessary frequency selection for output AC voltage and the ability of long distance energy transmission are some novelties and advantages of the proposed system. The proposed hybrid power source including DC/AC PWM inverter is simulated in Proteus 6 software environment and a laboratory-based prototype of the hybrid power source is constructed to validate the theoretical and simulation results. Simulation and experimental results are presented to prove the superiority of the proposed hybrid power supply

  9. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    OpenAIRE

    Md. Rajibur Rahaman Khan; Shin-Won Kang

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal?s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The...

  10. Distributed control system for parallel-connected DC boost converters

    Science.gov (United States)

    Goldsmith, Steven

    2017-08-15

    The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

  11. Isolated PDM and PWM DC-AC SICAMs[Pulse Density Modulated; Pulse Width Modulated

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report a class of isolated PDM and PWM DC-AC SICAMs is described, which introduce the audio reference only in the output stage. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitor. Isolation from the AC mains is achieved using a high frequency (HF) transformer, receiving the HF voltage pulses from the input 'inverter' stage and transferring them to the output 'rectifier+inverter' stage, which can use either PDM or PWM. The latter stage is then interfaced to the load using an output low-pass filter. Each of the dedicated stages is discussed in detail. Measurements on the master/slave PWM DC-AC SICAM prototype are presented to help benchmarking the performance of this class of SICAMs and identify the advantages and drawbacks. (au)

  12. The 120V 20A PWM switch for applications in high power distribution

    Science.gov (United States)

    Borelli, V.; Nimal, W.

    1989-08-01

    A 20A/120VDC (voltage direct current) PWM (Pulse Width Modulation) Solid State Power Controller (SSPC) developed under ESA contract to be used in the power distribution system of Columbus is described. The general characteristics are discussed and the project specification defined. The benefits of a PWM solution over a more conventional approach, for the specific application considered are presented. An introduction to the SSPC characteristics and a functional description are presented.

  13. The comparison of radiosensitivity of human lymphocytes stimulated with PHA Con A and PWM

    International Nuclear Information System (INIS)

    Geng Yongzhi; Su Liaoyuan

    1989-11-01

    The transformation, DNA strand breaks and its repair ability in human peripheral blood lymphocytes stimulated with PHA, Con A and PWM were respectively assessed following exposure to 60 Co gamma rays by 3 H-thymidine uptake and hydroxylapatite chromatography. It was showed the transformation of lymphocytes stimulated with PHA, Con A and PWM were suppressed by gamma rays and the dose-effect curves were biphase within the range of 0∼8 Gy. The lymphocytes stimulated with PWM was the most resistant to gamma rays. The extent of DNA strand breaks in lymphocytes induced by gamma rays was linearly related to the dose within the range of 0∼30 Gy and was identical in three kinds of lymphocytes. After post-irradiation incubation of 37 deg C, the DNA strand breaks could be repaired incompletely and after maxium repair the strand breaks were observed again. The repair ratio of strand breaks in the lymphocytes stimulated with PWM was the highest in the cells with three mitogens. The results showed that the difference of radiation effect on the transformation is probably related to the repair ability of DNA strand breaks

  14. The performance of the DC motor by the PID controlling PWM DC-DC boost converter

    OpenAIRE

    Can, Erol; Sayan, Hasan Hüseyin

    2017-01-01

    This paper presents the PID controlling direct current (DC) to the direct current boost converter feds DC motor which has a 3.68 kW and 240 V of DC voltage input on its characteristics. What is first formed is the boost converter mathematical model at the design stage. Secondly, a mathematical model of the DC motor is created so that the boost converter with the machine can be established and modeled at the Matlab Simulink. The PID controller is considered for arranging a pulse width modulati...

  15. Embedded system based on PWM control of hydrogen generator with SEPIC converter

    Science.gov (United States)

    Fall, Cheikh; Setiawan, Eko; Habibi, Muhammad Afnan; Hodaka, Ichijo

    2017-09-01

    The objective of this paper is to design and to produce a micro electrical plant system based on fuel cell for teaching material-embedded systems in technical vocational training center. Based on this, the student can experience generating hydrogen by fuel cells, controlling the rate of hydrogen generation by the duty ration of single-ended primary-inductor converter(SEPIC), drawing the curve rate of hydrogen to duty ratio, generating electrical power by using hydrogen, and calculating the fuel cell efficiency when it is used as electrical energy generator. This project is of great importance insofar as students will need to acquire several skills to be able to realize it such as continuous DC DC conversion and the scientific concept behind the converter, the regulation of systems with integral proportional controllers, the installation of photovoltaic cells, the use of high-tech sensors, microcontroller programming, object-oriented programming, mastery of the fuel cell syste

  16. Digitally Controlled Point of Load Converter with Very Fast Transient Response

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Andersen, Michael Andreas E.

    2007-01-01

    voltage mode control and very fast transient response. The DiSOM modulator is combined with a digital PID compensator algorithm is implemented in a hybrid CPLD/FPGA and is used to control a synchronous Buck converter, which is used in typical Point of Load applications. The computational time is only......This paper presents a new Digital Self-Oscillating Modulator (DiSOM) that allows the duty cycle to be changed instantly. The DiSOM modulator is shown to have variable switching that is a function of the duty cycle. Compared to a more traditional digital PWM modulator based on a counter...... and comparator the DiSOM modulator allows the sampling frequency of the output voltage control loop to be higher than the switching frequency of the power converter, typically a DC/DC converter. The features of the DiSOM modulator makes it possible to design a digitally controlled DC/DC converter with linear...

  17. High frequency three-phase PWM grid connected drive using silicon-carbide switches

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Pedersen, Jacob Lykke; Nymand, Morten

    2016-01-01

    This paper presents controller design procedure for a fully silicon-carbide (SiC) based three-phase grid-connected PWM drive. The influence of the feedforward compensation for the presented setup is studied and the transfer function of the system with feedforward is derived and compared with the ......This paper presents controller design procedure for a fully silicon-carbide (SiC) based three-phase grid-connected PWM drive. The influence of the feedforward compensation for the presented setup is studied and the transfer function of the system with feedforward is derived and compared...

  18. Power system stabilization by SMES using current-fed pwm power conditioner

    International Nuclear Information System (INIS)

    Ishikawa, T.; Akita, S.; Taniguchi, H.; Kosho, S.; Tanaka, T.

    1988-01-01

    A superconducting magnetic energy storage (SMES) unit, consisted of superconducting coil and AC/DC power conditioner, can be used to suppress various kinds of instability that may cause service interruption in electric power system as it has high controllability of input/output electric power. Power system stabilizing ability of SMES has been examined experimentally by using model power system and small SMES unit. Current-fed PWM power conditioner was used to obtain maximum stabilizing effect by controlling active and reactive power simultaneously and independently. Power conditioner configuration, operating characteristics and control scheme for power system stabilization are also described. Results from experiments show the effectiveness of SMES on power system stabilization

  19. Monolithic quasi-sliding-mode controller for SIDO buck converter with a self-adaptive free-wheeling current level

    International Nuclear Information System (INIS)

    Wu Xiaobo; Liu Qing; Zhao Menglian; Chen Mingyang

    2013-01-01

    An analog implementation of a novel fixed-frequency quasi-sliding-mode controller for single-inductor dual-output (SIDO) buck converter in pseudo-continuous conduction mode (PCCM) with a self-adaptive freewheeling current level (SFCL) is presented. Both small and large signal variations around the operation point are considered to achieve better transient response so as to reduce the cross-regulation of this SIDO buck converter. Moreover, an internal integral loop is added to suppress the steady-state regulation error introduced by conventional PWM-based sliding mode controllers. Instead of keeping it as a constant value, the free-wheeling current level varies according to the load condition to maintain high power efficiency and less cross-regulation at the same time. To verify the feasibility of the proposed controller, an SIDO buck converter with two regulated output voltages, 1.8 V and 3.3 V, is designed and fabricated in HEJIAN 0.35 μm CMOS process. Simulation and experiment results show that the transient time of this SIDO buck converter drops to 10 μs while the cross-regulation is reduced to 0.057 mV/mA, when its first load changes from 50 to 100 mA. (semiconductor integrated circuits)

  20. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-11-09

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  1. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    Science.gov (United States)

    Khan, Md. Rajibur Rahaman; Kang, Shin-Won

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal’s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R2 is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry–Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors. PMID:27834865

  2. Design and operation of a thermionic converter in air

    International Nuclear Information System (INIS)

    Horner, M.H.; Begg, L.L.; Smith, J.N. Jr.; Geller, C.B.; Kallnowski, J.E.

    1995-01-01

    An electrically heated thermionic converter has been designed, built and successfully tested in air. Several unique features were incorporated in this converter: an integral cesium reservoir, innovative ceramic-to-metal seals, a heat rejection system coupling the collector to a low temperature heat sink and an innovative cylindrical heater filament. The converter was operated for extended periods of time with the emitter at about 1900 K. the collector at about 700 K, and a power density of over 2 w(e)/sq. cm. Input power transients were run between 50% and 100% thermal power, at up to 1% per second, without instabilities in performance

  3. A Comparison of Phase-Shift Self- Oscillating and Carrier-based PWM Modulation for Embedded Audio Amplifiers

    OpenAIRE

    Huffenus , Alexandre; Pillonnet , Gaël; Abouchi , Nacer; Goutti , Frédéric

    2010-01-01

    International audience; This paper compares two modulation schemes for Class-D amplifiers: Phase-Shift Self-Oscillating (PSSO) and Carrier-Based Pulse Width Modulation (PWM). Theoretical analysis (modulation, frequency of oscillation, bandwidth…), design procedure, and IC silicon evaluation will be shown for mono and stereo operation (on the same silicon die) on both structures. The design of both architectures will use as many identical building blocks as possible, to provide a fair, "all el...

  4. Grid-friendly wind power systems based on the synchronverter technology

    International Nuclear Information System (INIS)

    Zhong, Qing-Chang; Ma, Zhenyu; Ming, Wen-Long; Konstantopoulos, George C.

    2015-01-01

    Highlights: • A grid-friendly wind power system that uses the synchronverter technology is proposed. • Both the rotor-side and the grid-side converters act as synchronverters. • The complete generator–motor–generator system improves the performance under grid faults. • Real-time digital simulation results verify the effectiveness of the proposed method. - Abstract: Back-to-back PWM converters are becoming a realistic alternative to conventional converters in high-power wind power applications. In this paper, a control strategy based on the synchronverter technology is proposed for back-to-back PWM converters. Both converters are run as synchronverters, which are mathematically equivalent to the conventional synchronous generators. The rotor-side converter is responsible for maintaining the DC link voltage and the grid-side converter is responsible for the maximum power point tracking (MPPT). As the two converters are operated using the synchronverter technology, the formed wind power system becomes more friendly to the grid. Extensive real-time digital simulation results are presented to verify the effectiveness of the proposed method under normal operation and grid-fault scenarios

  5. Control Strategy of PWM Rectifiers Connected to Unbalanced Grids

    Czech Academy of Sciences Publication Activity Database

    Bejvl, Martin; Švec, J.; Tlustý, J.; Valouch, V.

    -, č. 11 (2013) ISSN 2172-038X. [International Conference on Renewable Energies and Power Quality (ICREPQ´13). Bilbao, 20.03.2013-22.03.2013] Institutional support: RVO:61388998 Keywords : electric power system * PWM rectifier * dc voltage ripple Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  6. Thermal loading and reliability of 10 MW multilevel wind power converter at different wind roughness classes

    DEFF Research Database (Denmark)

    Isidori, Andrea; Rossi, Fabio Mario; Blaabjerg, Frede

    2012-01-01

    This paper focuses on the design, thermal loading and reliability of a three-level Neutral Point Clamped (3-L NPC) back-to-back full scale converter for a 10 MW direct-drive wind turbine equipped with a Permanent Magnet Synchronous Generator (PMSG). The reliability performance of the three......-level converter is strongly influenced by the thermal behaviour of the semiconductor devices and their mission profile which directly affects the lifetime and the cost of the whole converter. Therefore, the simulation platform is developed in Matlab/Simulink and PLECS simulation environment to analyse...... the dynamics of the system using different kinds of modulation strategies and analyzing different wind load conditions dependent on roughness classes. It is concluded that 60° discontinuous PWM modulation strategies show better thermal performance and increase the estimated lifetime of the converter...

  7. A 1 MEGAWATT POLYPHASE BOOST CONVERTER-MODULATOR FOR KLYSTRON PULSE APPLICATION

    International Nuclear Information System (INIS)

    Reass, W.A.; Doss, J.D.; Gribble, R.F.

    2001-01-01

    This paper describes electrical design criteria and first operational results a 140 kV, 1 MW average, 11 MW peak, zero-voltage-switching 20 kHz polyphase bridge, boost converter/modulator for klystron pulse application. The DC-DC converter derives the buss voltages from a standard 13.8 kV to 2300 Y substation cast-core transformer. Energy storage and filtering is provided by self-clearing metallized hazy polypropylene traction capacitors. Three ''H-Bridge'' Insulated Gate Bipolar Transistor (IGBT) switching networks are used to generate the polyphase 20 kHz transformer primary drive waveforms. The 20 kHz drive waveforms are chirped the appropriate duration to generate the desired klystron pulse width. PWM (pulse width modulation) of the individual 20 kHz pulses is utilized to provide regulated output waveforms with adaptive feedforward and feedback techniques. The boost transformer design utilizes amorphous nanocrystalline material that provides the required low core loss at design flux levels and switching frequencies. Resonant shunt-peaking is used on the transformer secondary to boost output voltage and resonate transformer leakage inductance. With the appropriate transformer leakage inductance and peaking capacitance, zero-voltage-switching of the IGBT's is attained, minimizing switching losses. A review of these design parameters and the first results of the performance characteristics will be presented

  8. Parallel implementation of DNA sequences matching algorithms using PWM on GPU architecture.

    Science.gov (United States)

    Sharma, Rahul; Gupta, Nitin; Narang, Vipin; Mittal, Ankush

    2011-01-01

    Positional Weight Matrices (PWMs) are widely used in representation and detection of Transcription Factor Of Binding Sites (TFBSs) on DNA. We implement online PWM search algorithm over parallel architecture. A large PWM data can be processed on Graphic Processing Unit (GPU) systems in parallel which can help in matching sequences at a faster rate. Our method employs extensive usage of highly multithreaded architecture and shared memory of multi-cored GPU. An efficient use of shared memory is required to optimise parallel reduction in CUDA. Our optimised method has a speedup of 230-280x over linear implementation on GPU named GeForce GTX 280.

  9. Simulation comparison of proportional integral derivative and fuzzy logic in controlling AC-DC buck boost converter

    Science.gov (United States)

    Faisal, A.; Hasan, S.; Suherman

    2018-03-01

    AC-DC converter is widely used in the commercial industry even for daily purposes. The AC-DC converter is used to convert AC voltage into DC. In order to obtain the desired output voltage, the converter usually has a controllable regulator. This paper discusses buck boost regulator with a power MOSFET as switching component which is adjusted based on the duty cycle of pulse width modulation (PWM). The main problems of the buck boost converter at start up are the high overshoot, the long peak time and rise time. This paper compares the effectiveness of two control techniques: proportional integral derivative (PID) and fuzzy logic control in controlling the buck boost converter through simulations. The results show that the PID is more sensitive to voltage change than fuzzy logic. However, PID generates higher overshoot, long peak time and rise time. On the other hand, fuzzy logic generates no overshoot and shorter rise time.

  10. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  11. RANCANG BANGUN SOLAR CHARGE CONTROLLER MENGGUNAKAN SYNCRONOUS NON-INVERTING BUCK-BOOST CONVERTER PADA PANEL SURYA 50 WATT PEAK (WP) BERBASIS ARDUINO NANO V3.0

    OpenAIRE

    Mahrubi, Irfan; Bintoro, Jusuf; Djatmiko, Wisnu

    2018-01-01

    Penelitian ini bertujuan untuk merancang bangun rangkaian synchronous non-inverting buck-boost converter (SNIBBC) untuk solar charge controller guna melakukan manajemen pengisian baterai dan manajemen beban dengan menggunakan Arduino Nano V3.0 ATMega 328. Rancang bangun rangkaian synchronous non-inverting buck-boost converter (SNIBBC) menggunakan empat mosfet yang bekerja secara saling singkron dengan dikontrol oleh pulsa PWM dari Timer1 arduino nano V3.0 ATMega 328 dengan frekuensi 10KHz men...

  12. Grid-connected Photovoltaic Micro-inverter with New Hybrid Control LLC Resonant Converter

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Qingbo, Ke

    2016-01-01

    A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse-frequency modulat......A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse......-frequency modulation (PFM) and phase-shift pulse-width modulation (PS-PWM) is employed on a full-bridge LLC dc-dc converter, in order to achieve high efficiency when PV output voltage varies in a wide range. Moreover, a maximum power point tracking (MPPT) method based on power perturbation is implemented in the dc...

  13. Synchronized Pulsed dc - dc Converter as Maximum Power Position Tracker with Wide Load and Insolation Variation for Stand Alone PV System

    International Nuclear Information System (INIS)

    Hardik, P. Desai; Ranjan Maheshwari

    2011-01-01

    This paper investigates the interest focused on employing parallel connected dc-dc converter with high tracking effectiveness under wide variation in environmental conditions (Insolation) and wide load variation. dc-dc converter is an essential part of the stand alone PV system. Paper also presents an approach on how duty cycle for maximum power position (MPP) is adjusted by taking care of varying load conditions and without iterative steps. Synchronized PWM pulses are employed for the converter. High tracking efficiency is achieved with continuous input and inductor current. In this approach, the converter can he utilized in buck as well in boost mode. The PV system simulation was verified and experimental results were in agreement to the presented scheme. (authors)

  14. A DEMODULATOR OF PWM SIGNALS GENERATED FOR A DIGITAL ACCELEROMETER IS DEVELOPED USING A MICROCONTROLLER UN DEMODULADOR DE SEÑALES PWM GENERADAS POR UN ACELERÓMETRO DIGITAL ES DESARROLLADO USANDO UN MICROCONTROLADOR

    Directory of Open Access Journals (Sweden)

    Eduardo Pérez Lobato

    2006-08-01

    Full Text Available This paper presents the use of a microcontroller to demodulate two Pulse Width Modulated (PWM signals which are being generated by a digital accelerometer, to obtain their pulse widths and transmit them serially to a parallel port of a general purpose computer.Esta publicación presenta el uso de un microcontrolador para demodular dos señales PWM que están siendo generadas por un acelerómetro digital, obtener sus anchos y enviarlas en forma serial al puerto paralelo de un computador de propósitos generales.

  15. A high efficiency PWM CMOS class-D audio power amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Zhangming; Liu Lianxi; Yang Yintang [Institute of Microelectronics, Xidian University, Xi' an 710071 (China); Lei Han, E-mail: zmyh@263.ne [Xi' an Power-Rail Micro Co., Ltd, Xi' an 710075 (China)

    2009-02-15

    Based on the difference close-loop feedback technique and the difference pre-amp, a high efficiency PWM CMOS class-D audio power amplifier is proposed. A rail-to-rail PWM comparator with window function has been embedded in the class-D audio power amplifier. Design results based on the CSMC 0.5 mum CMOS process show that the max efficiency is 90%, the PSRR is -75 dB, the power supply voltage range is 2.5-5.5 V, the THD+N in 1 kHz input frequency is less than 0.20%, the quiescent current in no load is 2.8 mA, and the shutdown current is 0.5 muA. The active area of the class-D audio power amplifier is about 1.47 x 1.52 mm{sup 2}. With the good performance, the class-D audio power amplifier can be applied to several audio power systems.

  16. A high efficiency PWM CMOS class-D audio power amplifier

    International Nuclear Information System (INIS)

    Zhu Zhangming; Liu Lianxi; Yang Yintang; Lei Han

    2009-01-01

    Based on the difference close-loop feedback technique and the difference pre-amp, a high efficiency PWM CMOS class-D audio power amplifier is proposed. A rail-to-rail PWM comparator with window function has been embedded in the class-D audio power amplifier. Design results based on the CSMC 0.5 μm CMOS process show that the max efficiency is 90%, the PSRR is -75 dB, the power supply voltage range is 2.5-5.5 V, the THD+N in 1 kHz input frequency is less than 0.20%, the quiescent current in no load is 2.8 mA, and the shutdown current is 0.5 μA. The active area of the class-D audio power amplifier is about 1.47 x 1.52 mm 2 . With the good performance, the class-D audio power amplifier can be applied to several audio power systems.

  17. A high efficiency PWM CMOS class-D audio power amplifier

    Science.gov (United States)

    Zhangming, Zhu; Lianxi, Liu; Yintang, Yang; Han, Lei

    2009-02-01

    Based on the difference close-loop feedback technique and the difference pre-amp, a high efficiency PWM CMOS class-D audio power amplifier is proposed. A rail-to-rail PWM comparator with window function has been embedded in the class-D audio power amplifier. Design results based on the CSMC 0.5 μm CMOS process show that the max efficiency is 90%, the PSRR is -75 dB, the power supply voltage range is 2.5-5.5 V, the THD+N in 1 kHz input frequency is less than 0.20%, the quiescent current in no load is 2.8 mA, and the shutdown current is 0.5 μA. The active area of the class-D audio power amplifier is about 1.47 × 1.52 mm2. With the good performance, the class-D audio power amplifier can be applied to several audio power systems.

  18. Interleaved Buck Converter with Variable Number of Active Phases and a Predictive Current Sharing Scheme

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Garcia, O.; Oliver, J. A.

    2008-01-01

    The efficiency of an interleaved Buck converter is typically low at light load conditions because of the switching losses in each of the switching stages. Improvements in the converter efficiency can be achieved by dynamically changing the number of active phases depending on the load current....... This paper addresses the issues related to the transient response of the converter when the number of active phases is changed by a digital control scheme. The problem arises because the current in the individual phases of the interleaved Buck converter will not be equal immediately after the controller has...... changed the number of active phases. This paper proposes a current equalisation scheme that adjusts the duty cycle of each phase in a manner that ensures equal average inductor current in all active phases in one or two PWM periods. The current equalisation scheme relies on the measurement of the output...

  19. Design, operation and control of series-connected power converters for offshore wind parks

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, Alejandro Garces

    2012-07-01

    Offshore wind farms need to develop technologies that fulfill three main objectives:Efficiency, power density and reliability. The purpose of this thesis is to study an HVDC transmission system based on series connection of the turbines which theoretically meet these three objectives. A new topology of matrix converter operated at high frequency is proposed. This converter is studied using different modulation algorithms. Simulation and experimental results demonstrated that the converter can be operated as a current source converter with high efficiency. An optimal control based on a linear quadratic regulator is propose dto control the matrix converter as well as the converter placed on shore. Results demonstrated the high performance of this type of control and its simplicity for implementation. An stationary state study based on non-linear programming and Montecarlo simulation was carried out to determine the performance of the concept for long-term operation. Series connection is an efficient technology if and only if the differences in the effective wind velocity are small. This aspect limits the number of wind turbines that can be connected in series, since a numerous number of turbines will lead to high covariances in the distribution of the wind. A complementary study about active filter and reactive power compensation was carried out using an optimization-based algorithm. (Author)

  20. Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

    Science.gov (United States)

    Bell, J. Brett; Nelms, R. M.; Shepherd, Michael T.

    1993-01-01

    The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

  1. Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

    Science.gov (United States)

    Bell, J. Brett; Nelms, R. M.; Shepherd, Michael T.

    The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

  2. Operation States Analysis of the Series-Parallel resonant Converter Working Above Resonance Frequency

    Directory of Open Access Journals (Sweden)

    Peter Dzurko

    2007-01-01

    Full Text Available Operation states analysis of a series-parallel converter working above resonance frequency is described in the paper. Principal equations are derived for individual operation states. On the basis of them the diagrams are made out. The diagrams give the complex image of the converter behaviour for individual circuit parameters. The waveforms may be utilised at designing the inverter individual parts.

  3. A current to voltage converter for cryogenics using a CMOS operational amplifier

    International Nuclear Information System (INIS)

    Hayashi, K; Saitoh, K; Shibayama, Y; Shirahama, K

    2009-01-01

    We have constructed a versatile current to voltage (I-V) converter operating at liquid helium temperature, using a commercially available all-CMOS OPamp. It is valuable for cryogenic measurements of electrical current of nano-pico amperes, for example, in scanning probe microscopy. The I-V converter is thermally linked to liquid helium bath and self-heated up to 10.7 K. We have confirmed its capability of a transimpedance gain of 10 6 V/A and a bandwidth from DC to 200 kHz. In order to test the practical use for a frequency-modulation atomic force microscope, we have measured the resonance frequency shift of a quartz tuning fork at 32 kHz. In the operation of the I-V converter close to the sensor at liquid helium temperature, the signal-to-noise ratio has been improved to a factor of 13.6 compared to the operation at room temperature.

  4. The PWM strategies of grid-connected distributed generation active NPC inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Xinmin, Jin; Kerekes, Tamas

    2009-01-01

    The Neutral Point Clamped topology due to high efficiency, low leakage current and EMI, its integration is widely used in the distributed generation (DG) systems. However the main disadvantage of the NPC inverter is given by an unequal distribution of the losses in the semiconductor devices, which...... leads to an unequal distribution of temperature. By using the Active NPC topology, the power losses distribution problem is alleviated. The modulation strategy is a key issue for losses distribution in this topology. In this paper two known strategies are discussed and a new proposed PWM strategy......, namely the Adjustable Losses Distribution (ALD) PWM strategy is proposed for better losses distribution in the Active NPC (ANPC) topology. Simulations using Simulink and the PLECS toolbox have been done for evaluating efficiency of different NPC topologies and some experimental results are presented...

  5. CCLIBS: The CERN Power Converter Control Libraries

    CERN Document Server

    AUTHOR|(SzGeCERN)404953; Lebioda, Krzysztof Tomasz; Magrans De Abril, Marc; Martino, Michele; Murillo Garcia, Raul; Nicoletti, Achille

    2015-01-01

    Accurate control of power converters is a vital activity in large physics projects. Several different control scenarios may coexist, including regulation of a circuit’s voltage, current, or field strength within a magnet. Depending on the type of facility, a circuit’s reference value may be changed asynchronously or synchronously with other circuits. Synchronous changes may be on demand or under the control of a cyclic timing system. In other cases, the reference may be calculated in real-time by an outer regulation loop of some other quantity, such as the tune of the beam in a synchrotron. The power stage may be unipolar or bipolar in voltage and current. If it is unipolar in current, it may be used with a polarity switch. Depending on the design, the power stage may be controlled by a firing angle or PWM duty-cycle reference, or a voltage or current reference. All these cases are supported by the CERN Converter Control Libraries (CCLIBS). These open-source C libraries include advanced reference generati...

  6. A Review of Passive Filters for Grid-Connected Voltage Source Converters

    DEFF Research Database (Denmark)

    Beres, Remus Narcis; Wang, Xiongfei; Blaabjerg, Frede

    2014-01-01

    LCL filter is the common interface between the Pulse Width Modulated Voltage Source Converter (PWM VSC) and the utility grid due to high harmonic attenuation capability and reduced size of the passive elements. The present paper investigates the most promising passive damping methods for the LCL...... topology but also propose an overview of high order filters capable to offer even more attenuation than the LCL filter at a reduced size. This is the case of more recently introduced LCL topology with tuned traps. However, it is shown that by decreasing the size of the passive elements the robustness...

  7. A current to voltage converter for cryogenics using a CMOS operational amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, K; Saitoh, K; Shibayama, Y; Shirahama, K [Department of Physics, Keio University, Yokohama 223-8522 (Japan)], E-mail: khayashi@a2.keio.jp

    2009-02-01

    We have constructed a versatile current to voltage (I-V) converter operating at liquid helium temperature, using a commercially available all-CMOS OPamp. It is valuable for cryogenic measurements of electrical current of nano-pico amperes, for example, in scanning probe microscopy. The I-V converter is thermally linked to liquid helium bath and self-heated up to 10.7 K. We have confirmed its capability of a transimpedance gain of 10{sup 6} V/A and a bandwidth from DC to 200 kHz. In order to test the practical use for a frequency-modulation atomic force microscope, we have measured the resonance frequency shift of a quartz tuning fork at 32 kHz. In the operation of the I-V converter close to the sensor at liquid helium temperature, the signal-to-noise ratio has been improved to a factor of 13.6 compared to the operation at room temperature.

  8. An online Vce measurement and temperature estimation method for high power IGBT module in normal PWM operation

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    An on-state collector-emitter voltage (Vce) measurement and thereby an estimation of average temperature in space for high power IGBT module is presented while power converter is in operation. The proposed measurement circuit is able to measure both high and low side IGBT and anti parallel diode...

  9. Parallel operation of voltage-source converters: issues and applications

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, F.C.B.; Silva, D.S. [Federal University of Juiz de Fora (UFJF), MG (Brazil)], Emails: felipe.brum@engenharia.ufjf.br, salomaoime@yahoo.com.br; Ribeiro, P.F. [Calvin College, Grand Rapids, MI (United States); Federal University of Juiz de Fora (UFJF), MG (Brazil)], E-mail: pfribeiro@ieee.org

    2009-07-01

    Technological advancements in power electronics have prompted the development of advanced AC/DC conversion systems with high efficiency and flexible performance. Among these devices, the Voltage-Source Converter (VSC) has become an essential building block. This paper considers the parallel operation of VSCs under different system conditions and how they can assist the operation of highly complex power networks. A multi-terminal VSC-based High Voltage Direct Current (M-VSC-HVDC) system is chosen to be modeled, simulated and then analyzed as an example of VSCs operating in parallel. (author)

  10. High-Speed Universal Frequency-to-Digital Converter for Quasi-Digital Sensors and Transducers

    Directory of Open Access Journals (Sweden)

    Sergey Y. Yurish

    2007-06-01

    Full Text Available New fast, accurate universal integrated frequency-to-digital converter (UFDC-1M-16 is described in the article. It is based on the novel patented modified method of the dependent count and has non-redundant conversion time from 6.25 ms to 6.25 ms for 1 to 0.001 % relative errors respectively, comparable with conversion time for successive-approximation and S-D ADC. The IC can work with different sensors, transducers and encoders, which have frequency, period, duty-cycle, PWM, phase shift, pulse number, etc. output.

  11. Novel operation and control modes for series-resonant converters

    NARCIS (Netherlands)

    Haan, de S.W.H.; Huisman, H.

    1985-01-01

    A series-resonant converter (SRC) able to generate an output voltage either lower or higher than the source voltage is described. Moreover, a novel control scheme is presented which renders two degrees of freedom for control and which guarantees symmetrical steady-state waveforms in all operation

  12. Operation strategy for grid-tied DC-coupling power converter interface integrating wind/solar/battery

    Science.gov (United States)

    Jou, H. L.; Wu, J. C.; Lin, J. H.; Su, W. N.; Wu, T. S.; Lin, Y. T.

    2017-11-01

    The operation strategy for a small-capacity grid-tied DC-coupling power converter interface (GDPCI) integrating wind energy, solar energy and battery energy storage is proposed. The GDPCI is composed of a wind generator, a solar module set a battery bank, a boost DC-DC power converter (DDPC), a bidirectional DDPC power converter, an AC-DC power converter (ADPC) and a five-level DC-AC inverter (DAI). A solar module set, a wind generator and a battery bank are coupled to the common DC bus through the boost DDPC, the ADPC and the bidirectional DDPC, respectively. For verifying the performance of the GDPCI under different operation modes, computer simulation is carried out by PSIM.

  13. Spectral shaping of a randomized PWM DC-DC converter using maximum entropy probability distributions

    CSIR Research Space (South Africa)

    Dove, Albert

    2017-01-01

    Full Text Available maintaining constraints in a DC-DC converter is investigated. A probability distribution whose aim is to ensure maximal harmonic spreading and yet mainaint constraints is presented. The PDFs are determined from a direct application of the method of Maximum...

  14. The Chaotic-Based Control of Three-Port Isolated Bidirectional DC/DC Converters for Electric and Hybrid Vehicles

    Directory of Open Access Journals (Sweden)

    Zheng Wang

    2016-01-01

    Full Text Available Three-port isolated (TPI bidirectional DC/DC converters have three energy ports and offer advantages of large voltage gain, galvanic isolation ability and high power density. For this reason this kind of converters are suitable to connect different energy sources and loads in electric and hybrid vehicles. The purpose of this paper is to propose chaotic modulation and the related control scheme for TPI bidirectional DC/DC converters, in such a way that the switching harmonic peaks can be suppressed in spectrum and the conducted electromagnetic interference (EMI is reduced. Two chaotic modulation strategies, namely the continuously chaotic modulation and the discretely chaotic modulation are presented. These two chaotic modulation strategies are applied for TPI bidirectional DC/DC converters with shifted-phase angle based control and phase-shifted PWM control. Both simulation and experiments are given to verify the validity of the proposed chaotic modulation-based control schemes.

  15. Impact of frequency modulation ratio on capacitor cells balancing in phase-shifted PWM based chain-link STATCOM

    DEFF Research Database (Denmark)

    Behrouzian, Ehsan; Bongiorno, Massimo; Teodorescu, Remus

    2014-01-01

    to provide more uniform power distribution among the cells, two different methods called, a) carrier swapping and b) non-integer frequency modulation ratio are studied. In particular, it is shown that the selection of a non-integer frequency modulation ratio helps in providing a more uniform power......The purpose of this paper is to investigate the impact of switching harmonics on the instantaneous power that flows in the cells of a chain-link based STATCOM when using Phase-Shifted PWM. Two different cases are investigated for the converter cells: low, and high switching frequency. It is shown...... that any deviation from the ideal conditions lead to undesired harmonics, which will impact the charge of the dc capacitors. It is also shown that for low switching frequencies, cells voltage sideband harmonics interact with baseband harmonics of the current and causes extra source of unbalance. In order...

  16. PWM Inverter control and the application thereof within electric vehicles

    Science.gov (United States)

    Geppert, Steven

    1982-01-01

    An inverter (34) which provides power to an A.C. machine (28) is controlled by a circuit (36) employing PWM control strategy whereby A.C. power is supplied to the machine at a preselectable frequency and preselectable voltage. This is accomplished by the technique of waveform notching in which the shapes of the notches are varied to determine the average energy content of the overall waveform. Through this arrangement, the operational efficiency of the A.C. machine is optimized. The control circuit includes a micro-computer and memory element which receive various parametric inputs and calculate optimized machine control data signals therefrom. The control data is asynchronously loaded into the inverter through an intermediate buffer (38). In its preferred embodiment, the present invention is incorporated within an electric vehicle (10) employing a 144 VDC battery pack (32) and a three-phase induction motor (18).

  17. Analysis of a PWM Resonant Buck Chopper for Use as a Ship Service Converter Module

    National Research Council Canada - National Science Library

    Ciezki, John

    1999-01-01

    .... This study provides a background analysis into resonant converters which utilize zero-voltage-switching and zero-current-switching techniques to mitigate the aforementioned concerns and facilitate...

  18. Elimination of zero sequence circulating current between parallel operating three-level inverters

    DEFF Research Database (Denmark)

    Li, Kai; Wang, Xiaodong; Dong, Zhenhua

    2016-01-01

    In order to suppress the zero sequence circulating currents (ZSCCs) between parallel operating three level voltage source inverters with common AC and DC buses, a common mode voltage reduction PWM (CMVR-PWM) technique and neural point potentials (NPPs) control based method is proposed in this paper...

  19. Application of digital PWM technology in current transducers

    International Nuclear Information System (INIS)

    Liu Huifang; Hu Zhimin; Li Rui

    2012-01-01

    With the development of DSP technology and mature use of PID technology,, a new program for DC or AC signal measurement is proposed. Combined with the DSP chip timer module and PID algorithm, PWM signals are generated to control the feedback circuit for the compensation current. Finally the measured current value can be obtained according to the ampere-turns compensation current and the measured current. Studies have shown that this technology enables new current transducers have high stability. (authors)

  20. Stator insulation systems for medium voltage PWM drives fed motors

    International Nuclear Information System (INIS)

    Gao, G.; Chen, W.

    2005-01-01

    This paper presents the partial results of a research project that studied the impact of medium voltage PWM ASD (adjustable speed drives) on motor stator insulation system. The findings from this study/ investigation have aided designers to improve the robustness of the insulation system used for ASD-fed motors, based on accelerated laboratory tests. (author)

  1. A High-Frequency Isolation (HFI Charging DC Port Combining a Front-End Three-Level Converter with a Back-End LLC Resonant Converter

    Directory of Open Access Journals (Sweden)

    Guowei Cai

    2017-09-01

    Full Text Available The high-frequency isolation (HFI charging DC port can serve as the interface between unipolar/bipolar DC buses and electric vehicles (EVs through the two-power-stage system structure that combines the front-end three-level converter with the back-end logical link control (LLC resonant converter. The DC output voltage can be maintained within the desired voltage range by the front-end converter. The electrical isolation can be realized by the back-end LLC converter, which has the bus converter function. According to the three-level topology, the low-voltage rating power devices can be adapted for half-voltage stress of the total DC grid, and the PWM phase-shift control can double the equivalent switching frequency to greatly reduce the filter volume. LLC resonant converters have advance characteristics of inverter-side zero-voltage-switching (ZVS and rectifier-side zero-current switching (ZCS. In particular, it can achieve better performance under quasi-resonant frequency mode. Additionally, the magnetizing current can be modified following different DC output voltages, which have the self-adaptation ZVS condition for decreasing the circulating current. Here, the principles of the proposed topology are analyzed in detail, and the design conditions of the three-level output filter and high-frequency isolation transformer are explored. Finally, a 20 kW prototype with the 760 V input and 200–500 V output are designed and tested. The experimental results are demonstrated to verify the validity and performance of this charging DC port system structure.

  2. Microcontroller based PWM controlled four switch three phase inverter fed induction motor drive

    Directory of Open Access Journals (Sweden)

    Mohanty Kant Nalin

    2010-01-01

    Full Text Available This paper presents PIC microcontroller based PWM inverter controlled four switch three phase inverter (FSTPI fed Induction Motor drive. The advantage of this inverter that uses of 4 switches instead of conventional 6 switches is lesser switching losses, lower electromagnetic interference (EMI, less complexity of control algorithms and reduced interface circuits. Simulation and experimental work are carried out and results presented to demonstrate the feasibility of the proposed approach. Simulation is carried out using MATLAB SIMULINK and in the experimental work a prototype model is built to verify the simulation results. PIC microcontroller (PIC 16F877A is used to generate the PWM pulses for FSTPI to drive the 0.5 hp 3-phase Induction Motor.

  3. A simplified time-domain design and implementation of cascaded PI ...

    Indian Academy of Sciences (India)

    LENIN PRAKASH

    Performance analysis based on field test results using real-time weather data validates the proposed design. ... applications such as photovoltaic (PV) solar systems, fuel cells, etc. ...... 2001 Averaged modeling of PWM converters operating in.

  4. Performance analysis of pulse analog control schemes for LLC resonant DC/DC converters suitable in portable applications

    Directory of Open Access Journals (Sweden)

    P. Kowstubha

    2016-12-01

    Full Text Available Performance Analysis of Pulse Analog Control Schemes, predominantly Pulse-Width Modulation (PWM and Pulse-Position Modulation (PPM for LLC resonant DC/DC converter suitable in portable applications is addressed in this paper. The analysis is done for closed loop performance, frequency domain performance, primary and secondary side conduction losses and soft commutation using PSIM 6.0 software and observed that PPM scheme provides better performance at high input voltage with a good selectivity of frequency over a wide range of line and load variations. The performance of LLC resonant DC/DC converter is demonstrated using PPM scheme for a design specifications of 12 V, 5 A output.

  5. Switch mode power supply

    International Nuclear Information System (INIS)

    Kim, Hui Jun

    1993-06-01

    This book concentrates on switch mode power supply. It has four parts, which are introduction of switch mode power supply with DC-DC converter such as Buck converter boost converter, Buck-boost converter and PWM control circuit, explanation for SMPS with DC-DC converter modeling and power mode control, resonance converter like resonance switch, converter, multi resonance converter and series resonance and parallel resonance converters, basic test of SMPS with PWM control circuit, Buck converter, Boost converter, flyback converter, forward converter and IC for control circuit.

  6. Operation Analysis of the Series-Parallel Resonant Converter Working above Resonance Frequency

    Directory of Open Access Journals (Sweden)

    Peter Dzurko

    2006-01-01

    Full Text Available The present article deals with theoretical analysis of operation of a series-parallel converter working above resonance frequency. Derived are principal equations for individual operation intervals. Based on these made out are waveforms of individual quantities during both the inverter operation at load and no-load operation. The waveforms may be utilised at designing the inverter individual parts.

  7. An improved fault-tolerant control scheme for PWM inverter-fed induction motor-based EVs.

    Science.gov (United States)

    Tabbache, Bekheïra; Benbouzid, Mohamed; Kheloui, Abdelaziz; Bourgeot, Jean-Matthieu; Mamoune, Abdeslam

    2013-11-01

    This paper proposes an improved fault-tolerant control scheme for PWM inverter-fed induction motor-based electric vehicles. The proposed strategy deals with power switch (IGBTs) failures mitigation within a reconfigurable induction motor control. To increase the vehicle powertrain reliability regarding IGBT open-circuit failures, 4-wire and 4-leg PWM inverter topologies are investigated and their performances discussed in a vehicle context. The proposed fault-tolerant topologies require only minimum hardware modifications to the conventional off-the-shelf six-switch three-phase drive, mitigating the IGBTs failures by specific inverter control. Indeed, the two topologies exploit the induction motor neutral accessibility for fault-tolerant purposes. The 4-wire topology uses then classical hysteresis controllers to account for the IGBT failures. The 4-leg topology, meanwhile, uses a specific 3D space vector PWM to handle vehicle requirements in terms of size (DC bus capacitors) and cost (IGBTs number). Experiments on an induction motor drive and simulations on an electric vehicle are carried-out using a European urban driving cycle to show that the proposed fault-tolerant control approach is effective and provides a simple configuration with high performance in terms of speed and torque responses. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Primary Paralleled Isolated Boost Converter with Extended Operating Voltage Range

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Sen, Gökhan; Mira Albert, Maria del Carmen

    2012-01-01

    Applications requiring wide input and output voltage range cannot often be satisfied by using buck or boost derived topologies. Primary paralleled isolated boost converter (PPIBC) [1]-[2] is a high efficiency boost derived topology. This paper proposes a new operation mode for extending the input...

  9. Synchronised PWM Schemes for Three-level Inverters with Zero Common-mode Voltage

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    This paper presents results of analysis and comparison of novel synchronised schemes of pulsewidth modulation (PWM), applied to three-level voltage source inverters with control algorithms providing elimination of the common-mode voltage. The proposed approach is based on a new strategy of digital...

  10. A New N-Level Inverter Based on Z-NPC

    Directory of Open Access Journals (Sweden)

    E. Babaei

    2017-12-01

    Full Text Available First of all, in this paper, the topology and operation of the three-phase three-level Z-source inverter based on neutral-point-clamped (Z-NPC are studied. Moreover, different combinations of permissible switching states and control signals are explained for this inverter. In this paper, the topology of the three-phase three-level Z-NPC inverter is extended for an n-level state. Also, a combination of allowed switching states with relevant mathematical equations is presented for the proposed n-level Z-NPC inverter. In comparison with multilevel voltage-source inverters (only voltage-boost capability, the proposed multilevel Z-NPC inverter is a single-stage converter and it has a buck-boost capability of voltage. On the other hand, the control of two-stage converters compared to single-stage converters can be more difficult because of existing more active and passive components. In this paper, two new PWM control methods are also proposed for various multilevel Z-NPC inverters. One advantage of the proposed PWM control methods in comparison with conventional PWM control methods is maintaining the charge balance of the dc-link capacitors in neutral point. The correct performance of the proposed multilevel Z-NPC topology and PWM control methods are verified by the obtained results of analysis and simulations performed in the PSCAD software.

  11. Full-Circle Resolver-to-Linear-Analog Converter

    Science.gov (United States)

    Alhorn, Dean C.; Smith, Dennis A.; Howard, David E.

    2005-01-01

    A circuit generates sinusoidal excitation signals for a shaft-angle resolver and, like the arctangent circuit described in the preceding article, generates an analog voltage proportional to the shaft angle. The disadvantages of the circuit described in the preceding article arise from the fact that it must be made from precise analog subcircuits, including a functional block capable of implementing some trigonometric identities; this circuitry tends to be expensive, sensitive to noise, and susceptible to errors caused by temperature-induced drifts and imprecise matching of gains and phases. These disadvantages are overcome by the design of the present circuit. The present circuit (see figure) includes an excitation circuit, which generates signals Ksin(Omega(t)) and Kcos(Omega(t)) [where K is an amplitude, Omega denotes 2(pi)x a carrier frequency (the design value of which is 10 kHz), and t denotes time]. These signals are applied to the excitation terminals of a shaft-angle resolver, causing the resolver to put out signals C sin(Omega(t)-Theta) and C cos(Omega(t)-Theta). The cosine excitation signal and the cosine resolver output signal are processed through inverting comparator circuits, which are configured to function as inverting squarers, to obtain logic-level or square-wave signals .-LL[cos(Omega(t)] and -LL[cos(Omega(t)-Theta)], respectively. These signals are fed as inputs to a block containing digital logic circuits that effectively measure the phase difference (which equals Theta between the two logic-level signals). The output of this block is a pulse-width-modulated signal, PWM(Theta), the time-averaged value of which ranges from 0 to 5 VDC as Theta ranges from .180 to +180deg. PWM(Theta) is fed to a block of amplifying and level-shifting circuitry, which converts the input PWM waveform to an output waveform that switches between precise reference voltage levels of +10 and -10 V. This waveform is processed by a two-pole, low-pass filter, which removes

  12. interval type-2 fuzzy gain-adaptive controller of a doubly fed

    African Journals Online (AJOL)

    Loukal K and Benalia L

    2016-05-01

    May 1, 2016 ... machine a converter PWM (Pulse Width Modulation) between the machine ... operations on fuzzy sets increases with the increasing type of the fuzzy set. ...... Several simulations have been run using the Matlab and Simulink® ...

  13. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2015-01-01

    converter topology based on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling...... is therefore very sensitive to step load changes. Comprehensive simulation results and experimental results are presented to show the effectiveness of the proposed circuit and control algorithm....

  14. Math Model and Calculation Analysis of Inter-harmonic of Double PWM Speed Control System in Distribution Network

    Directory of Open Access Journals (Sweden)

    Yang Wen-Huan

    2014-11-01

    Full Text Available Aiming at the problem that the distribution network voltage will fluctuate because of the inter-harmonic currents injected into the network by double PWM speed control system when regulating the speed of the asynchronous motor, we established the inter-harmonic current math model of double PWM speed control system according to switching function based on a real bridge crane. The distribution law of the inter-harmonic is got by calculating the grid-side currents and their spectrum while letting the motor run at different quadrants and frequencies. The result which is verified by simulation and experiment shows that the content of the inter harmonic currents is more than that of harmonic currents in double PWM speed control system, the frequency of the inter harmonics of the grid-side current mainly focus on the scope lower than the fundamental frequency, and when the motor runs at low frequencies, the THD of the grid-side current is high. The result has verified the reason why the voltage of a bridge crane distribution system of a deepwater port in Shanghai flickers.

  15. Stability Analysis and Trigger Control of LLC Resonant Converter for a Wide Operational Range

    Directory of Open Access Journals (Sweden)

    Zhijian Fang

    2017-09-01

    Full Text Available The gain of a LLC resonant converter can vary with the loads that can be used to improve the efficiency and power density for some special applications, where the maximum gain does not apply at the heaviest loads. However, nonlinear gain characteristics can make the converters unstable during a major disturbance. In this paper, the stability of an LLC resonant converter during a major disturbance is studied and a trigger control scheme is proposed to improve the converter’s stability by extending the converter’s operational range. Through in-depth analysis of the gain curve of the LLC resonant converter, we find that the switching frequency range is one of the key factors determining the system’s stability performance. The same result is also obtained from a mathematical point of view by utilizing the mixed potential function method. Then a trigger control method is proposed to make the LLC resonant converter stable even during a major disturbance, which can be used to extend the converter’s operational range. Finally, experimental results are given to verify the analysis and proposed control scheme.

  16. Perspective gyrotron with mode converter for co- and counter-rotation operating modes

    Energy Technology Data Exchange (ETDEWEB)

    Chirkov, A. V.; Kuftin, A. N. [Institute of Applied Physics, Russian Academy of Sciences, 46 Ul' yanov Street, 603950 Nizhny Novgorod (Russian Federation); Denisov, G. G. [Institute of Applied Physics, Russian Academy of Sciences, 46 Ul' yanov Street, 603950 Nizhny Novgorod (Russian Federation); University of Nizhny Novgorod, 23 Prospekt Gagarina, 603950 Nizhny Novgorod (Russian Federation)

    2015-06-29

    A gyrotron oscillator operating efficiently at modes of both rotations was developed and tested. The gyrotron operation can be switched between two modes: co- and counter rotating ones with respect to electron rotation in a resonance magnetic field. A synthesized mode converter provides output of both waves in the form of two different paraxial wave beams corresponding to direction of the mode rotation. Measured gyrotron power (up to 2 MW), interaction efficiency (34%), and diffraction losses in the mode converter (≈2%) agree well with the design values. The proposed gyrotron scheme alloys principal enhancement in the device parameters—possibility of electronic switching of output wave beam direction and possibility to arrange an effective scheme to provide frequency/phase locking of a gyrotron-oscillator.

  17. Perspective gyrotron with mode converter for co- and counter-rotation operating modes

    International Nuclear Information System (INIS)

    Chirkov, A. V.; Kuftin, A. N.; Denisov, G. G.

    2015-01-01

    A gyrotron oscillator operating efficiently at modes of both rotations was developed and tested. The gyrotron operation can be switched between two modes: co- and counter rotating ones with respect to electron rotation in a resonance magnetic field. A synthesized mode converter provides output of both waves in the form of two different paraxial wave beams corresponding to direction of the mode rotation. Measured gyrotron power (up to 2 MW), interaction efficiency (34%), and diffraction losses in the mode converter (≈2%) agree well with the design values. The proposed gyrotron scheme alloys principal enhancement in the device parameters—possibility of electronic switching of output wave beam direction and possibility to arrange an effective scheme to provide frequency/phase locking of a gyrotron-oscillator

  18. An analytical inductor design procedure for three-phase PWM converters in power factor correction applications

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Niroumand, Farideh Javidi; Haase, Frerk

    2015-01-01

    This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyze...... to calculate the core loss in the PFC application. To investigate the impact of the dc link voltage level, two inductors for different dc voltage levels are designed and the results are compared.......This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyzes...... circuit is used to provide the inductor current harmonic spectrum. Therefore, using the harmonic spectrum, the low and high frequency copper losses are calculated. The high frequency minor B-H loops in one switching cycle are also analyzed. Then, the loss map provided by the measurement setup is used...

  19. PWM Regulation of Grid-Tied PV System on the Base of Photovoltaic-Fed Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    Oleschuk V.I.

    2015-12-01

    Full Text Available Investigation of grid-tied photovoltaic system on the base of two diode-clamped inverters, controlled by specific algorithms of pulse-width modulation (PWM, has been done. This system includes two strings of photovoltaic panels feeding two diode-clamped inverters. The outputs of inverters are connected with the corresponding windings on the primary side of three-phase transformer, connected with a grid. In order to reduce phase voltage distortion and to increase efficiency of operation of the system, special scheme of control and modulation of inverters has been used, providing minimization of common-mode voltages and voltage waveforms symmetries under different operating conditions. Detailed simulation of processes in this photovoltaic-fed power conversion system has been executed. The results of simulations verify good performance of photovoltaic system regulated in accordance with specific strategy of control and modulation.

  20. Open-circuit fault detection and tolerant operation for a parallel-connected SAB DC-DC converter

    DEFF Research Database (Denmark)

    Park, Kiwoo; Chen, Zhe

    2014-01-01

    This paper presents an open-circuit fault detection method and its tolerant control strategy for a Parallel-Connected Single Active Bridge (PCSAB) dc-dc converter. The structural and operational characteristics of the PCSAB converter lead to several advantages especially for high power applicatio...

  1. AC-DC PFC Converter Using Combination of Flyback Converter and Full-bridge DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Moh. Zaenal Efendi

    2014-06-01

    Full Text Available This paper presents a combination of power factor correction converter using Flyback converter and Full-bridge dc-dc converter in series connection. Flyback converter is operated in discontinuous conduction mode so that it can serve as a power factor correction converter and meanwhile Full-bridge dc-dc converter is used for dc regulator. This converter system is designed to produce a 86 Volt of output voltage and 2 A of output current. Both simulation and experiment results show that the power factor of this converter achieves up to 0.99 and meets harmonic standard of IEC61000-3-2. Keywords: Flyback Converter, Full-bridge DC-DC Converter, Power Factor Correction.

  2. Performance analysis of commercial MOSFET packages in Class E converter operating at 2.56 MHz

    DEFF Research Database (Denmark)

    Nair, Unnikrishnan Raveendran; Munk-Nielsen, Stig; Jørgensen, Asger Bjørn

    2017-01-01

    resistance and high temperature operation over Si devices have aided in the paradigm shift towards wide bandgap devices. The low gate charge requirements of SiC MOSFETs enables use of these devices in radio frequency (RF) converters using resonant topologies operating at MHz frequency range. The RF...... are not commercially available and power modules have to be custom designed for these applications. This work demonstrates performance of various commercial MOSFET packages at frequency of 2.56 MHz. Commercial SiC MOSFETs in TO-247 and D2Pak packs are tested in Class E resonant converter operating at 2.56 MHz...

  3. A New Method to Implement Resampled Uniform PWM Suitable for Distributed Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Huang, Shaojun; Mathe, Laszlo; Teodorescu, Remus

    2013-01-01

    Two existing methods to implement resampling modulation technique for modular multilevel converter (MMC) (the sampling frequency is a multiple of the carrier frequency) are: the software solution (using a microcontroller) and the hardware solution (using FPGA). The former has a certain level...

  4. Small-Signal Analysis of Single-Phase and Three-phase DC/AC and AC/DC PWM Converters with the Frequency-Shift Technique

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Aquila, A. Dell’; Liserre, Marco

    2004-01-01

    of dc/dc converters via a 50 Hz frequency-shift. The input admittance is calculated and measured for two study examples (a three-phase active rectifier and a single-phase photovoltaic inverter). These examples show that the purpose of a well designed controller for grid-connected converters......A systematic approach to study dc/ac and ac/dc converters without the use of synchronous transformation is proposed. The use of a frequency-shift technique allows a straightforward analysis of single-phase and three-phase systems. The study of dc/ac and of ac/dc converters is reported to the study...... is to minimize the input admittance in order to make the grid converter more robust to grid disturbance....

  5. Distributed Generation using Indirect Matrix Converter in Boost Operating Mode

    DEFF Research Database (Denmark)

    Liu, Xiong; Loh, Poh Chiang; Wang, Peng

    2011-01-01

    , reverse power flow operation of IMC can be implemented to meet voltage boost requirement, where the input ac source is connected to the converter's voltage source side and the output utility grid or load is connected to the current source side. This paper proposes control schemes of IMC under reverse...... power flow operation for both grid-connected and isolated modes with distributed generation suggested as a potential application. In grid-connected mode, the commanded power must be extracted from the input ac source to the grid, in addition to guarantee sinusoidal input/output waveforms, unity input...

  6. High Voltage Gain Dual Active Bridge Converter with an Extended Operation Range for Renewable Energy Systems

    DEFF Research Database (Denmark)

    Zhang, Zhe; Tomas Manez, Kevin; Yudi, Xiao

    2018-01-01

    Bridge (P2DAB) converter, i.e. low-voltage (LV) side parallel and high-voltage (HV) side series, is proposed to achieve high voltage gain and low current stress over switching devices and transformer windings. Given the unmodified P2DAB power stage, by regulating the phase-shift angle between......Developing bidirectional dc-dc converters has become a critical research topic and gains more and more attention in recent years due to the extensive applications of smart grids with energy storages, hybrid and electrical vehicles and dc microgrids. In this paper, a Partial Parallel Dual Active...... the paralleled active bridges, the power equations and voltage gain are then modified, and therefore the operation range can be extended effectively. The operating principles of the proposed converter and its power characteristics under various operation modes are studied, and the design constraints...

  7. Tipe Dry Cell dan Wet Cell berdimensi 80 x 80 mm dengan Penambahan PWM E-3 FF (1 kHz

    Directory of Open Access Journals (Sweden)

    Yanur Arzaqa Ghiffari

    2013-09-01

    Full Text Available Ketersediaan bahan bakar minyak semakin terbatas dan hasil pembakarannya berdampak pada pencemaran lingkungan, salah satu solusinya dengan memanfaatkan gas HHO pada kendaraan bermotor. Penelitian dengan sistem direct connection, temperatur mencapai lebih dari 90oC menyebabkan  generator HHO menjadi rusak dan meleleh, maka penelitian ini menambahan alat untuk mengkontrol besarnya arus, frekuensi, dan duty cycle. Pengembangan generator HHO menggunakan tipe kering (dry cell dan tipe basah (wet cell dengan penambahan PWM (Pulse Width Modulation E-3 Fixed Frequency 1 kHz divariasikan berupa duty cycle: 20%, 40%, 60%, 80%  dan direct connection. Pengujian dilakukan di Laboratorium Teknik Pembakaran dan Bahan Bakar - Teknik Mesin ITS.  Dari hasil penelitian didapatkan karakteristik unjuk kerja terbaik pada kedua tipe generator HHO dengan penambahan PWM. Nilai arus dan tegangan lebih stabil dibandingkan dengan tanpa penambahan PWM (direct connection, namun arus cenderung meningkat seiring dengan kenaikan temperatur mencapai 70oC. Efisiensi terbaik pada generator tipe wet dengan duty cycle 80%,  yaitu 27,7 %.

  8. Highly Sensitive Temperature Sensors Based on Fiber-Optic PWM and Capacitance Variation Using Thermochromic Sensing Membrane

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-07-01

    Full Text Available In this paper, we propose a temperature/thermal sensor that contains a Rhodamine-B sensing membrane. We applied two different sensing methods, namely, fiber-optic pulse width modulation (PWM and an interdigitated capacitor (IDC-based temperature sensor to measure the temperature from 5 °C to 100 °C. To the best of our knowledge, the fiber-optic PWM-based temperature sensor is reported for the first time in this study. The proposed fiber-optic PWM temperature sensor has good sensing ability; its sensitivity is ~3.733 mV/°C. The designed temperature-sensing system offers stable sensing responses over a wide dynamic range, good reproducibility properties with a relative standard deviation (RSD of ~0.021, and the capacity for a linear sensing response with a correlation coefficient of R2 ≈ 0.992 over a wide sensing range. In our study, we also developed an IDC temperature sensor that is based on the capacitance variation principle as the IDC sensing element is heated. We compared the performance of the proposed temperature-sensing systems with different fiber-optic temperature sensors (which are based on the fiber-optic wavelength shift method, the long grating fiber-optic Sagnac loop, and probe type fiber-optics in terms of sensitivity, dynamic range, and linearity. We observed that the proposed sensing systems have better sensing performance than the above-mentioned sensing system.

  9. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  10. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    Science.gov (United States)

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  11. Multiple low frequency dual reference PWM control of a grid connected photovoltaic three phase NPC inverter with DC/DC boost converter

    Directory of Open Access Journals (Sweden)

    Mechouma Rabiaa

    2014-01-01

    Full Text Available In recent years, power demand of industrial applications has increased significantly reaching some megawatts. The use of multilevel converters for applications of medium and high powers is proposed as a solution to drawback semiconductor technology. A multilevel converter not only achieves high power ratings, but also enables the use of renewable energy sources. Renewable energy sources such as photovoltaic can be easily interfaced to a multilevel converter system for a high power application. This paper presents the simulation study in Matlab/Simulink of a grid connected photovoltaic three phase Neutral Point Clamped (NPC inverter with DC/DC boost converter for constant and variable solar radiation.

  12. Analysis and Mitigation of Dead Time Harmonics in the Single-Phase Full-Bridge PWM Converters with Repetitive Controllers

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Wang, Huai

    2018-01-01

    In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot-through in voltage source converters during a switching period, the dead time is added either in the hardware driver circuits of the IGBTs or implemented in software in Pulse-Width Modul......In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot-through in voltage source converters during a switching period, the dead time is added either in the hardware driver circuits of the IGBTs or implemented in software in Pulse...

  13. A High Power Boost Converter for PV Systems Operating up to 300 kHz using SiC Devices

    DEFF Research Database (Denmark)

    Anthon, Alexander; Zhang, Zhe; Andersen, Michael A. E.

    2014-01-01

    In this paper, a 3kW boost converter for PV applications using SiC devices is introduced. Main focus is to operate the converter over a wide range of switching frequency and to analyze the main loss distributors as well as the efficiency. The switching element is a recently introduced normally...... be operated at full power for a switching frequency of 100 kHz using natural cooling. At 200 kHz the boost converter is capable of operating at full power when forced air cooling is applied having a JFET case temperature of less than 90 C. The case temperature of the JFET increases up to 110 C at a switching...

  14. Design and operating experience of an ac-dc power converter for a superconducting magnetic energy storage unit

    International Nuclear Information System (INIS)

    Boenig, H.J.; Nielsen, R.G.; Sueker, K.H.

    1984-01-01

    The design philosophy and the operating behavior of a 5.5 kA, +-2.5 kV converter, being the electrical interface between a high voltage transmission system and a 30 MJ superconducting coil, are documented in this paper. Converter short circuit tests, load tests under various control conditions, dc breaker tests for magnet current interruption, and converter failure modes are described

  15. Effect of metallurgical factors on the magnetic properties of non-oriented electrical steels under PWM excitation

    International Nuclear Information System (INIS)

    Tanaka, T.; Yashiki, H.; Takada, S.; Sasaki, T.

    1994-01-01

    Magnetic properties of non-oriented electrical steel sheets under PWM voltage excitation as well as those under sinusoidal excitation have been investigated from a metallurgical point of view. The core loss under PWM excitation is slightly larger than that under sinusoidal excitation. The induction dependence of the core loss difference between the two excitation conditions changes by changing Si content and grain size. The higher the induction, the larger the core loss difference of 0.2% Si steel with small grains. In the case of higher Si steels and 0.2% Si steel with large grain sizes, however, the core loss difference at inductions over 1.3 T decreases with increasing induction. At low induction levels the core loss difference has little relationship to the grain size. On the other hand, at high induction levels this difference decreases with increasing grain size. ((orig.))

  16. Maximum Power Point Tracking for Cascaded PV-Converter Modules Using Two-Stage Particle Swarm Optimization.

    Science.gov (United States)

    Mao, Mingxuan; Duan, Qichang; Zhang, Li; Chen, Hao; Hu, Bei; Duan, Pan

    2017-08-24

    The paper presents a novel two-stage particle swarm optimization (PSO) for the maximum power point tracking (MPPT) control of a PV system consisting of cascaded PV-converter modules, under partial shading conditions (PSCs). In this scheme, the grouping method of the shuffled frog leaping algorithm (SFLA) is incorporated with the basic PSO algorithm, ensuring fast and accurate searching of the global extremum. An adaptive speed factor is also introduced to improve its convergence speed. A PWM algorithm enabling permuted switching of the PV sources is applied. The method enables this PV system to achieve the maximum power generation for any number of PV and converter modules. Simulation studies of the proposed MPPT scheme are performed on a system having two chained PV buck-converter modules and a dc-ac H-bridge connected at its terminals for supplying an AC load. The results show that this type of PV system allows each module to achieve the maximum power generation according its illumination level without affecting the others, and the proposed new control method gives significantly higher power output compared with the conventional P&O and PSO methods.

  17. A Novel Multilevel DC - AC Converter from Green Energy Power Generators Using Step-Square Waving and PWM Technique

    Science.gov (United States)

    Fajingbesi, F. E.; Midi, N. S.; Khan, S.

    2017-06-01

    Green energy sources or renewable energy system generally utilize modular approach in their design. This sort of power sources are generally in DC form or in single cases AC. Due to high fluctuation in the natural origin of this energy (wind & solar) source they are stored as DC. DC power however are difficult to transfer over long distances hence DC to AC converters and storage system are very important in green energy system design. In this work we have designed a novel multilevel DC to AC converter that takes into account the modular design of green energy systems. A power conversion efficiency of 99% with reduced total harmonic distortion (THD) was recorded from our simulated system design.

  18. AC Small Signal Modeling of PWM Y-Source Converter by Circuit Averaging and Averaged Switch Modeling Technique

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam Prasad; Blaabjerg, Frede

    2016-01-01

    Magnetically coupled Y-source impedance network is a newly proposed structure with versatile features intended for various power converter applications e.g. in the renewable energy technologies. The voltage gain of the Y-source impedance network rises exponentially as a function of turns ratio, w...

  19. A Comprehensive Analysis and Hardware Implementation of Control Strategies for High Output Voltage DC-DC Boost Power Converter

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2017-01-01

    Full Text Available Classical DC-DC converters used in high voltage direct current (HVDC power transmission systems, lack in terms of efficiency, reduced transfer gain and increased cost with sensor (voltage/current numbers. Besides, the internal self-parasitic behavior of the power components reduces the output voltage and efficiency of classical HV converters. This paper deals with extra high-voltage (EHV dc-dc boost converter by the application of voltage-lift technique to overcome the aforementioned deficiencies. The control strategy is based on classical proportional-integral (P-I and fuzzy logic closed-loop controller to get high and stable output voltage. Complete hardware prototype of EHV is implemented and experimental tasks are carried out with digital signal processor (DSP TMS320F2812. The control algorithms P-I, fuzzy logic and the pulse-width modulation (PWM signals for N-channel MOSFET device are performed by the DSP. The experimental results provided show good conformity with developed hypothetical predictions. Additionally, the presented study confirms that the fuzzy logic controller provides better performance than classical P-I controller under different perturbation conditions.

  20. Six-Phase Vehicular Drive with Renewable DC Sources and Hybrid PWM Control of Four Inverters

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Ermuratskii, Vladimir; Blaabjerg, Frede

    2015-01-01

    The paper presents results of research of quad-inverter-based automotive system with combined scheme of PWM control of inverters, supplied by two renewable dc sources (by fuel cells and by battery). It has been shown, that hybrid switching techniques can be used successfully for control of vehicle...

  1. High power density dc/dc converter: Selection of converter topology

    Science.gov (United States)

    Divan, Deepakraj M.

    1990-01-01

    The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

  2. Cascaded resonant bridge converters

    Science.gov (United States)

    Stuart, Thomas A. (Inventor)

    1989-01-01

    A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

  3. Single-phase to three-phase converter system of high quality for rural applications and distributed generation; Sistema conversor mono-trifasico de alta qualidade para aplicacoes rurais e de geracao distribuida

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Ricardo Q.; Pomilio, Jose A. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Eletrica e de Computacao], e-mail: ricardom@dsce.fee.unicamp.br; Buso, Simone [Universidade de Padova, Padua (Italy). Dept. de Engenharia da Informacao], e-mail: simone.buso@dei.unipd.it

    2004-07-01

    This paper describes a line-interactive single-phase to three-phase converter. The typical application is in rural areas supplied by the single-wire with earth return. The traditional objective of feeding a three-phase induction motor is not anymore the main concern for such conversion. Due to the evolution of the agro business, some of the local load (as electronic power converters, computers, communication equipment, etc.) requires high quality power, intended as sinusoidal, symmetrical and balanced three-phase voltage. Additionally, to maximize the power got from the feeder, the system provides a unitary power factor to the feeder. A three-phase PWM converter is used for this purpose. The power converter does not process all the load power, as in the conventional solutions, but only the fraction necessary to regulate the three-phase bus voltage. The control strategy, design highlights and experimental results are presented. (author)

  4. Development of ATC for High Speed and High Density Commuter Line

    Science.gov (United States)

    Okutani, Tamio; Nakamura, Nobuyuki; Araki, Hisato; Irie, Shouji; Osa, Hiroki; Sano, Minoru; Ikeda, Keigo; Ozawa, Hiroyuki

    A new ATC (Automatic Train Control) system has been developed with solutions to realize short train headway by assured braking utilizing digital data transmission via rails; the digital data for the ATP (Automatic Train Protection) function; and to achieve EMC features for both AC and DC sections. The DC section is of the unprecedented DC traction power supply system utilizing IGBT PWM converter at all DC substations. Within the AC section, train traction force is controlled by PWM converter/inverters. The carrier frequencies of the digital data signals and chopping frequency of PWM traction power converters on-board are decided via spectral analysis of noise up to degraded mode cases of equipment. Developed system was equipped to the Tukuba Express Line, new commuter line of Tokyo metropolitan area, and opened since Aug. 2005.

  5. Modelling and Controller Design of Electro-Pneumatic Actuator Based on PWM

    Directory of Open Access Journals (Sweden)

    Behrouz Najjari

    2012-07-01

    Full Text Available In this paper, a nonlinear model associated to the fast switching on-off solenoid valve and pneumatic cylinder was dynamically presented. Furthermore, an investigation into the electrical, magnetic, mechanical and fluid subsystems are made. Two common control policies to track valve position, a Proportional Integrator (PI based on Pulse Width Modulation (PWM and hysteresis controllers, are investigated. To control cylinder position, a Programmable Logic Controller (PLC on a simulated unit and an experimental setup regulated with AVR microcontroller are carried out. Experimental results show effective validation to the simulation results from PLC.

  6. Simulation Results of Double Forward Converter

    Directory of Open Access Journals (Sweden)

    P. Vijaya KUMAR

    2009-12-01

    Full Text Available This work aims to find a better forward converter for DC to DC conversion.Simulation of double forward converter in SMPS system is discussed in this paper. Aforward converter with RCD snubber to synchronous rectifier and/or to current doubleris also discussed. The evolution of the forward converter is first reviewed in a tutorialfashion. Performance parameters are discussed including operating principle, voltageconversion ratio, efficiency, device stress, small-signal dynamics, noise and EMI. Itscircuit operation and its performance characteristics of the forward converter with RCDsnubber and double forward converter are described and the simulation results arepresented.

  7. Modeling, Dynamics, Bifurcation Behavior and Stability Analysis of a DC-DC Boost Converter in Photovoltaic Systems

    Science.gov (United States)

    Zhioua, M.; El Aroudi, A.; Belghith, S.; Bosque-Moncusí, J. M.; Giral, R.; Al Hosani, K.; Al-Numay, M.

    A study of a DC-DC boost converter fed by a photovoltaic (PV) generator and supplying a constant voltage load is presented. The input port of the converter is controlled using fixed frequency pulse width modulation (PWM) based on the loss-free resistor (LFR) concept whose parameter is selected with the aim to force the PV generator to work at its maximum power point. Under this control strategy, it is shown that the system can exhibit complex nonlinear behaviors for certain ranges of parameter values. First, using the nonlinear models of the converter and the PV source, the dynamics of the system are explored in terms of some of its parameters such as the proportional gain of the controller and the output DC bus voltage. To present a comprehensive approach to the overall system behavior under parameter changes, a series of bifurcation diagrams are computed from the circuit-level switched model and from a simplified model both implemented in PSIM© software showing a remarkable agreement. These diagrams show that the first instability that takes place in the system period-1 orbit when a primary parameter is varied is a smooth period-doubling bifurcation and that the nonlinearity of the PV generator is irrelevant for predicting this phenomenon. Different bifurcation scenarios can take place for the resulting period-2 subharmonic regime depending on a secondary bifurcation parameter. The boundary between the desired period-1 orbit and subharmonic oscillation resulting from period-doubling in the parameter space is obtained by calculating the eigenvalues of the monodromy matrix of the simplified model. The results from this model have been validated with time-domain numerical simulation using the circuit-level switched model and also experimentally from a laboratory prototype. This study can help in selecting the parameter values of the circuit in order to delimit the region of period-1 operation of the converter which is of practical interest in PV systems.

  8. Operation and thermal loading of three-level Neutral-Point-Clamped wind power converter under various grid faults

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Liserre, Marco

    2012-01-01

    In order to fulfill the continuous growing grid-side demands, the full-scale power converters are becoming more and more popular in the wind power application. Nevertheless, the more severe loading of the power semiconductor devices in the full-scale power converters, especially during Low Voltage...... Ride Through (LVRT) operation under grid faults, may compromise the reliability of the system and consequently further increase its cost. In this paper, the impact of various grid faults on a three-level Neutral-Point-Clamped (3L-NPC) grid-converter in terms of thermal loading of power semiconductor...

  9. Technologies for converter topologies

    Science.gov (United States)

    Zhou, Yan; Zhang, Haiyu

    2017-02-28

    In some embodiments of the disclosed inverter topologies, an inverter may include a full bridge LLC resonant converter, a first boost converter, and a second boost converter. In such embodiments, the first and second boost converters operate in an interleaved manner. In other disclosed embodiments, the inverter may include a half-bridge inverter circuit, a resonant circuit, a capacitor divider circuit, and a transformer.

  10. Commutation Processes in Multiresonant ZVS Bridge Converter

    Directory of Open Access Journals (Sweden)

    Miroslaw Luft

    2008-01-01

    Full Text Available The analysis of the multiresonant ZVS DC/DC bridge converter is presented. The control system of the converter is basedon the method of frequency control at the constant time of transistor turn-off with a phase shift. The operation of the circuit is givenand the operating range of the converter is defined where ZVS switching operation is assured. Control characteristics are given andthe converter’s efficiency is defined. The circuit’s operation is analysed on the basis of results of the converter simulation tests using Simplorer programme.

  11. Programmable Power Supply for AC Switching Magnet of Proton Accelerator

    CERN Document Server

    Jeong, Seong-Hun; Kang Heung Sik; Lee, Chi-Hwan; Lee, Hong-Gi; Park, Ki-Hyeon; Ryu, Chun-Kil; Sik Han, Hong; Suck Suh, Hyung

    2005-01-01

    The 100-MeV PEFP proton linac has two proton beam extraction lines for user' experiment. Each extraction line has 5 beamlines and has 5 Hz operating frequency. An AC switching magnet is used to distribute the proton beam to the 5 beamlines, An AC switching magnet is powered by PWM-controlled bipolar switching-mode converters. This converter is designed to operate at ±350A, 5 Hz programmable step output. The power supply is employed IGBT module and has controlled by a DSP (Digital Signal Process). This paper describes the design and test results of the power supply.

  12. Elimination of DC-Link Current Ripple for Modular Multilevel Converters With Capacitor Voltage-Balancing Pulse-Shifted Carrier PWM

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2015-01-01

    The modular multilevel converter (MMC) is attractive for medium- and high-power applications because of its high modularity, availability, and power quality. In this paper, the current ripple on the dc link of the three-phase MMC derived from the phase-shifted carrier-based pulse-width modulation...

  13. The COP9 signalosome converts temporal hormone signaling to spatial restriction on neural competence.

    Directory of Open Access Journals (Sweden)

    Yi-Chun Huang

    2014-11-01

    Full Text Available During development, neural competence is conferred and maintained by integrating spatial and temporal regulations. The Drosophila sensory bristles that detect mechanical and chemical stimulations are arranged in stereotypical positions. The anterior wing margin (AWM is arrayed with neuron-innervated sensory bristles, while posterior wing margin (PWM bristles are non-innervated. We found that the COP9 signalosome (CSN suppresses the neural competence of non-innervated bristles at the PWM. In CSN mutants, PWM bristles are transformed into neuron-innervated, which is attributed to sustained expression of the neural-determining factor Senseless (Sens. The CSN suppresses Sens through repression of the ecdysone signaling target gene broad (br that encodes the BR-Z1 transcription factor to activate sens expression. Strikingly, CSN suppression of BR-Z1 is initiated at the prepupa-to-pupa transition, leading to Sens downregulation, and termination of the neural competence of PWM bristles. The role of ecdysone signaling to repress br after the prepupa-to-pupa transition is distinct from its conventional role in activation, and requires CSN deneddylating activity and multiple cullins, the major substrates of deneddylation. Several CSN subunits physically associate with ecdysone receptors to represses br at the transcriptional level. We propose a model in which nuclear hormone receptors cooperate with the deneddylation machinery to temporally shutdown downstream target gene expression, conferring a spatial restriction on neural competence at the PWM.

  14. Test setup for accelerated test of high power IGBT modules with online monitoring of Vce and Vf voltage during converter operation

    DEFF Research Database (Denmark)

    de Vega, Angel Ruiz; Ghimire, Pramod; Pedersen, Kristian Bonderup

    2014-01-01

    Several accelerated test methods exist in order to study the failures mechanisms of the high power IGBT modules like temperature cycling test or power cycles based on DC current pulses. The main drawback is that the test conditions do not represent the real performance and stress conditions...... of the device in real application. The hypothesis is that ageing of power modules closer to real environment including cooling system, full dc-link voltage and continuous PWM operation could lead to more accurate study of failure mechanism. A new type of test setup is proposed, which can create different real...... load conditions like in the field. Furthermore, collector-emitter voltage (Vce) has been used as indicator of the wear-out of the high power IGBT module. The innovative monitoring system implemented in the test setup is capable of measure the Vce and forward voltage of the antiparallel diode (Vf...

  15. On-grid and Off-grid Operation of Multi-Input Single-Output DC/DC Converter based Fuel Cell Generation System

    Directory of Open Access Journals (Sweden)

    Noroozian

    2009-06-01

    Full Text Available This paper presents the modeling and simulation of a proton exchange membrane fuel cell (PEMFC generation system for off-grid and on-grid operation and configuration. A fuel cell DG system consists of a fuel cell power plant, a DC/DC converter and a DC/AC inverter. The dynamic model for fuel cell array and its power electronic interfacing are presented also a multi-input single output (MISO DC/DC converter and its control scheme is proposed and analyzed. This DC/DC converter is capable of interfacing fuel cell arrays to the DC/AC inverter. Also the mathematical model of the inverter is obtained by using average technique. Then the novel control strategy of DC/AC inverter for different operating conditions is demonstrated. The simulation results show the effectiveness of the suggested control systems under both on-grid and off-grid operation modes.

  16. A Sepic Type Switched Mode Power Supply System For Battery Charging In An Electric Tricycle Auto-Rickshaw

    Directory of Open Access Journals (Sweden)

    Kureve

    2017-08-01

    Full Text Available This paper analyzes the plug-in electric tricycle Auto rickshaw battery charging system using a non-isolated DC-DC SEPIC converter which operates as a switched mode power supply SMPS. The control of dc voltage output is by varying the gating pulses duty cycle of the switch in the dc-dc converter using PID controller based PWM technique. The 60 V 30 A DC-DC SEPIC converter is designed to provide non-inverting voltage buck from the rectified AC mains for charging deep cycle battery bank in an electric auto rickshaw. The charger system is implemented using MATLABSimulink.

  17. A new PWM algorithm for battery-source three-phase inverters

    Energy Technology Data Exchange (ETDEWEB)

    Chan, C.C. (Dept. of Electrical and Electronic Engineering, Univ. of Hong Kong, Pokfulam Road (HK)); Chau, K.T. (Dept. of Electrical Engineering, Hong Kong Polytechnic, Hung Hom (HK))

    1991-01-01

    A new PWM algorithm for battery-source three-phase inverters is described in this paper. The concept of the algorithm is to determine the pulsewidths by equating the areas of the segments of the sinusodial reference with the related output pulse areas. The algorithm is particularly suitable to handle a non-constant voltage source with good harmonic suppression. Since the pulsewidths are computable in real time with minimal storage requirement as well as compact hardware and software, it is especially suitable for single-chip microcomputer implementation. Experimental results show that the single-chip microcomputer Intel 8095-based battery-source inverter can control a 3 kW synchronous motor drive satisfactorily over a frequency range of 2 to 100Hz.

  18. Deployment and Maintenance of Wave Energy Converters at the Lysekil Research Site: A Comparative Study on the Use of Divers and Remotely-Operated Vehicles

    Directory of Open Access Journals (Sweden)

    Flore Rémouit

    2018-04-01

    Full Text Available Ocean renewable technologies have been rapidly developing over the past years. However, current high installation, operation, maintenance, and decommissioning costs are hindering these offshore technologies to reach a commercialization stage. In this paper we focus on the use of divers and remotely-operated vehicles during the installation and monitoring phase of wave energy converters. Methods and results are based on the wave energy converter system developed by Uppsala University, and our experience in offshore deployments obtained during the past eleven years. The complexity of underwater operations, carried out by either divers or remotely-operated vehicles, is emphasized. Three methods for the deployment of wave energy converters are economically and technically analyzed and compared: one using divers alone, a fully-automated approach using remotely-operated vehicles, and an intermediate approach, involving both divers and underwater vehicles. The monitoring of wave energy converters by robots is also studied, both in terms of costs and technical challenges. The results show that choosing an autonomous deployment method is more advantageous than a diver-assisted method in terms of operational time, but that numerous factors prevent the wide application of robotized operations. Technical solutions are presented to enable the use of remotely-operated vehicles instead of divers in ocean renewable technology operations. Economically, it is more efficient to use divers than autonomous vehicles for the deployment of six or fewer wave energy converters. From seven devices, remotely-operated vehicles become advantageous.

  19. Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

    Science.gov (United States)

    Gallegos-Lopez, Gabriel [Torrance, CA; Nagashima, James M [Cerritos, CA; Perisic, Milun [Torrance, CA; Hiti, Silva [Redondo Beach, CA

    2012-02-14

    A system is provided for controlling two AC machines. The system comprises a DC input voltage source that provides a DC input voltage, a voltage boost command control module (VBCCM), a five-phase PWM inverter module coupled to the two AC machines, and a boost converter coupled to the inverter module and the DC input voltage source. The boost converter is designed to supply a new DC input voltage to the inverter module having a value that is greater than or equal to a value of the DC input voltage. The VBCCM generates a boost command signal (BCS) based on modulation indexes from the two AC machines. The BCS controls the boost converter such that the boost converter generates the new DC input voltage in response to the BCS. When the two AC machines require additional voltage that exceeds the DC input voltage required to meet a combined target mechanical power required by the two AC machines, the BCS controls the boost converter to drive the new DC input voltage generated by the boost converter to a value greater than the DC input voltage.

  20. Semi-automatic logarithmic converter of logs

    International Nuclear Information System (INIS)

    Gol'dman, Z.A.; Bondar's, V.V.

    1974-01-01

    Semi-automatic logarithmic converter of logging charts. An original semi-automatic converter was developed for use in converting BK resistance logging charts and the time interval, ΔT, of acoustic logs from a linear to a logarithmic scale with a specific ratio for subsequent combining of them with neutron-gamma logging charts in operative interpretation of logging materials by a normalization method. The converter can be used to increase productivity by giving curves different from those obtained in manual, pointwise processing. The equipment operates reliably and is simple in use. (author)

  1. Development of a wind energy converter and investigation of its operational function. Part 4: Test setup and results of measurement

    Science.gov (United States)

    Armbrust, S.; Molly, J. P.

    1982-12-01

    Measurements made during test operations at the MODA.10 plant as well as at a 25 years old 6 kW wind energy converter are presented. The test arrangements, measurement results of both wind energy converters, and the experience gained are described.

  2. DC motor operation controlled from a DC/DC power converter in pulse mode with low duty cycle

    OpenAIRE

    Stefanov, Goce; Kukuseva, Maja; Citkuseva Dimitrovska, Biljana

    2016-01-01

    In this paper pulse mode of operation of DC motor controlled by DC/DC power converter is analyzed. DC motor operation with time intervals in which the motor operates without output load is of interest. In this mode it is possible the motor to restore energy. Also, in the paper are represented calculations for the amount of the restored energy in the pulse mode operation of the motor for different duty cycles.

  3. Operation and Control of a Direct-Driven PMSG-Based Wind Turbine System with an Auxiliary Parallel Grid-Side Converter

    Directory of Open Access Journals (Sweden)

    Jiawei Chu

    2013-07-01

    Full Text Available In this paper, based on the similarity, in structure and principle, between a grid-connected converter for a direct-driven permanent magnet synchronous generator (D-PMSG and an active power filter (APF, a new D-PMSG-based wind turbine (WT system configuration that includes not only an auxiliary converter in parallel with the grid-side converter, but also a coordinated control strategy, is proposed to enhance the low voltage ride through (LVRT capability and improve power quality. During normal operation, the main grid-side converter maintains the DC-link voltage constant, whereas the auxiliary grid-side converter functions as an APF with harmonic suppression and reactive power compensation to improve the power quality. During grid faults, a hierarchical coordinated control scheme for the generator-side converter, main grid-side converter and auxiliary grid-side converter, depending on the grid voltage sags, is presented to enhance the LVRT capability of the direct-driven PMSG WT. The feasibility and the effectiveness of the proposed system’s topology and hierarchical coordinated control strategy were verified using MATLAB/Simulink simulations.

  4. Desain dan Realisasi Sistem Komunikasi Cahaya Tampak untuk Streaming Teks berbasis PWM

    Directory of Open Access Journals (Sweden)

    Trio Adiono

    2017-12-01

    Full Text Available The design and implementation of visible light communication systems for transmitting digital data (texts have been discussed in this paper. Then, two evaluations were performed also, i.e. the demonstration of streaming text through the visible light as a proof-of-concept system design. The next evaluation is a BER measurement intended to know the VLC system performance quantitatively. The value of BER against the several parameters: by the variation of distance and its reception angle. The proposed VLC system works well until the photodiode reception angle to the LEDs up to 50°. According to evaluation, our system can operate optimally within 30 – 80 cm or 50 – 130 cm of optical channel range depending on the Gain setting option. To support the reliability of noise from ambient light and interference lamps such as fluorescent lamps, the filters circuit are employed: high pass filter and DC-offset remover. Based on the BER analysis, the filters can compensate the problem of ambient light noise (DC-offset signal and interference lamp (100-150 Hz of carrier frequency. The speed of data-rate obtained with 1-PWM modulation and the low-cost analog component is 3.3 kbps.

  5. Hydrogen converters

    International Nuclear Information System (INIS)

    Mondino, Angel V.

    2003-01-01

    The National Atomic Energy Commission of Argentina developed a process of 99 Mo production from fission, based on irradiation of uranium aluminide targets with thermal neutrons in the RA-3 reactor of the Ezeiza Atomic Centre. These targets are afterwards dissolved in an alkaline solution, with the consequent liberation of hydrogen as the main gaseous residue. This work deals with the use of a first model of metallic converter and a later prototype of glass converter at laboratory scale, adjusted to the requirements and conditions of the specific redox process. Oxidized copper wires were used, which were reduced to elementary copper at 400 C degrees and then regenerated by oxidation with hot air. Details of the bed structure and the operation conditions are also provided. The equipment required for the assembling in cells is minimal and, taking into account the operation final temperature and the purge with nitrogen, the procedure is totally safe. Finally, the results are extrapolated for the design of a converter to be used in a hot cell. (author)

  6. Inverter for interfacing advanced energy sources to a utility grid

    Science.gov (United States)

    Steigerwald, Robert L.

    1984-01-01

    A transistor is operated in the PWM mode such that a hlaf sine wave of current is delivered first to one-half of a distribution transformer and then the other as determined by steering thyristors operated at the fundamental sinusoidal frequency. Power to the transistor is supplied by a dc source such as a solar array and the power is converted such that a sinusoidal current is injected into a utility at near unity power factor.

  7. ITER convertible blanket evaluation

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Cheng, E.

    1995-01-01

    Proposed International Thermonuclear Experimental Reactor (ITER) convertible blankets were reviewed. Key design difficulties were identified. A new particle filter concept is introduced and key performance parameters estimated. Results show that this particle filter concept can satisfy all of the convertible blanket design requirements except the generic issue of Be blanket lifetime. If the convertible blanket is an acceptable approach for ITER operation, this particle filter option should be a strong candidate

  8. Adaptive electrothermal protection of power converters

    Directory of Open Access Journals (Sweden)

    Baraniuk G. A.

    2017-06-01

    Full Text Available Thermal management for power converters during normal operation and transient modes when electrical components are warmed up is an actual problem. This can be particularly important for converters with intermittent duty operation, e.g. power supplies for resistance welding. According to some research, nearly 60% of failures are temperature-induced, and for every 10°C temperature rise in operating environment the failure rate nearly doubles. In this paper, thermal motion of state equations eigenvalue is analysed. It is shown, that in semiconductor converters with an output smoothing filter it is appropriate to use thermal protection devices based on thermal normalisation of the converter filter and, while for cases when short circuits are possible it is appropriate to use a soft start system with thermal adaptation for soft start time factor. Based on these results, two systems of thermal protections operating for semiconductor power converters are introduced. Simulation of combined electromagnetic and thermal processes in buck converter operating with both thermal management systems in overlapping environments MATLAB/Simulink and PLECS showed the possibility to significantly reduce thermal shock on semiconductor components. Using the system of filter parameters normalisation decreases the temperature of the crystal from 210°C to 85°C, using the adaptive soft start system decreases the temperature from 180°C to 80°C. The simulation results are confirmed by tests on real devices.

  9. Synchronized Scheme of Continuous Space-Vector PWM with the Real-Time Control Algorithms

    DEFF Research Database (Denmark)

    Oleschuk, V.; Blaabjerg, Frede

    2004-01-01

    This paper describes in details the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of three-phase voltage source inverters for adjustable speed ac drives. It is applied to a continuous scheme of voltage space vector modulation. The method is based...... their position inside clock-intervals. In order to provide smooth shock-less pulse-ratio changing and quarter-wave symmetry of the voltage waveforms, special synchronising signals are formed on the boundaries of the 60 clock-intervals. The process of gradual transition from continuous to discontinuous...

  10. Estimating return levels from maxima of non-stationary random sequences using the Generalized PWM method

    Directory of Open Access Journals (Sweden)

    P. Ribereau

    2008-12-01

    Full Text Available Since the pioneering work of Landwehr et al. (1979, Hosking et al. (1985 and their collaborators, the Probability Weighted Moments (PWM method has been very popular, simple and efficient to estimate the parameters of the Generalized Extreme Value (GEV distribution when modeling the distribution of maxima (e.g., annual maxima of precipitations in the Identically and Independently Distributed (IID context. When the IID assumption is not satisfied, a flexible alternative, the Maximum Likelihood Estimation (MLE approach offers an elegant way to handle non-stationarities by letting the GEV parameters to be time dependent. Despite its qualities, the MLE applied to the GEV distribution does not always provide accurate return level estimates, especially for small sample sizes or heavy tails. These drawbacks are particularly true in some non-stationary situations. To reduce these negative effects, we propose to extend the PWM method to a more general framework that enables us to model temporal covariates and provide accurate GEV-based return levels. Theoretical properties of our estimators are discussed. Small and moderate sample sizes simulations in a non-stationary context are analyzed and two brief applications to annual maxima of CO2 and seasonal maxima of cumulated daily precipitations are presented.

  11. Analysis of bi-directional piezoelectric-based converters for zero-voltage switching operation

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Zhang, Zhe; Andersen, Michael A. E.

    2016-01-01

    This paper deals with a thorough analysis of zerovoltage switching especially for bi-directional, inductorless, piezoelectric transformer-based switch-mode power supplies with a half-bridge topology. Practically, obtaining zero-voltage switching for all of the switches in a bi-directional piezoel......This paper deals with a thorough analysis of zerovoltage switching especially for bi-directional, inductorless, piezoelectric transformer-based switch-mode power supplies with a half-bridge topology. Practically, obtaining zero-voltage switching for all of the switches in a bi......-directional piezoelectric power converter is a difficult task. However, the analysis in this work will be convenient for overcoming this challenge. The analysis defines the zero-voltage region indicating the operating points whether or not soft switching can be met over the switching frequency and load range. For the first...... time, a comprehensive analysis is provided, which can be used as a design guideline for applying control techniques in order to drive switches in piezoelectric transformer-based converters. This study further conveys the proposed method to the region where all the switches can obtain soft switching...

  12. Constant-frequency, clamped-mode resonant converters

    Science.gov (United States)

    Tsai, Fu-Sheng; Materu, Peter; Lee, Fred C.

    1987-01-01

    Two novel clamped-mode resonant converters are proposed which operate at a constant frequency while retaining many desired features of conventional series- and parallel-resonant converters. State-plane analysis techniques are used to identify all possible operating modes and define their mode boundaries. Control-to-output characteristics are derived that specify the regions for natural and forced commutation. The predicted operating modes are verified using a prototype circuit.

  13. Modeling of asymmetrical boost converters

    Directory of Open Access Journals (Sweden)

    Eliana Isabel Arango Zuluaga

    2014-01-01

    Full Text Available The asymmetrical interleaved dual boost (AIDB is a fifth-order DC/DC converter designed to interface photovoltaic (PV panels. The AIDB produces small current harmonics to the PV panels, reducing the power losses caused by the converter operation. Moreover, the AIDB provides a large voltage conversion ratio, which is required to step-up the PV voltage to the large dc-link voltage used in grid-connected inverters. To reject irradiance and load disturbances, the AIDB must be operated in a closed-loop and a dynamic model is required. Given that the AIDB converter operates in Discontinuous Conduction Mode (DCM, classical modeling approaches based on Continuous Conduction Mode (CCM are not valid. Moreover, classical DCM modeling techniques are not suitable for the AIDB converter. Therefore, this paper develops a novel mathematical model for the AIDB converter, which is suitable for control-pur-poses. The proposed model is based on the calculation of a diode current that is typically disregarded. Moreover, because the traditional correction to the second duty cycle reported in literature is not effective, a new equation is designed. The model accuracy is contrasted with circuital simulations in time and frequency domains, obtaining satisfactory results. Finally, the usefulness of the model in control applications is illustrated with an application example.

  14. Artificial neural network control of sab dc/dc converter

    International Nuclear Information System (INIS)

    Mahar, M.A.; Abro, M.R.; Larik, A.S.

    2009-01-01

    The latest development of power semiconductor devices enable the modern power electronic converters to withstand high voltage and high power applications. Power electronic converters are mostly periodic variable structure systems due to their switched operations. The main drawback of these converters is the generation of oscillations which are developed during the operation of the converters under nonlinear situations. To handle these nonlinearities, various researchers have proposed different control techniques. Power electronic designers are devoting in the further development of converter topologies and their control techniques. SAB (Single Active Bridge) DC/DC converter is a new topology recently introduced by Demetriades. This topology is used in high voltage and high power applications. Because of its smart features, SAB converter has recently drawn attention of many researchers. However, during the operation of SAB converter severe oscillations are generated. In this research work, a novel NNC (Neural Network Controller) model is developed for SAB converter to minimize oscillations generated during its operation. NNC is believed to be an advanced nonlinear and robust controller which has the ability to map the nonlinear behaviour in a negligible response time. The performance of SAB converter with NNC is tested under dynamic region by considering the reference voltage variation and duty ratio variation. The SAB converter is implemented and simulated in MATLAB/Simulink. The simulated results are presented. (author)

  15. Predictive digital peak current mode controller for DC-DC converters capable of operating over the full 0-100% duty cycle range

    DEFF Research Database (Denmark)

    Andersen, Karsten Holm; Nymand, Morten

    2017-01-01

    ) and discontinuous conduction mode (DCM) and supports high switching frequencies even with low cost A/D converters. The proposed controller is implemented in a Field Programmable Gate Array (FPGA) to control a 450 W buck converter and the experimental results verify the controller's capability to operate in the full...

  16. Battery pack state of charge balancing algorithm for cascaded H-Bridge multilevel converters

    DEFF Research Database (Denmark)

    Máthé, Lászlo; Burlacu, Paul Dan; Schaltz, Erik

    2016-01-01

    For most of the Multilevel Converter (MC) applications a commonly discussed issue is the maintenance of balance between the energy storage elements from the SubModules (SM). In applications where a battery pack is also part of the SM storage, such as STATCOMs or motor drives, the SM voltage...... is not in linear relation with the State Of Charge (SOC) of the entire battery; thus, the balancing becomes more cumbersome. A method to balance the SOC of the battery packs in a system using cascaded H-Bridge is proposed in this paper. The method uses nearest level control followed by sorting and selection based...... on the SOC of the battery packs. Based on the simulation results the number of switching is reduced considerably compared to the method where the phase shifted PWM is used. In addition, the time needed to achieve the balanced SOC is also reduced. The proposed method has been verified through experiments...

  17. Flicker Mitigation of Grid Connected Wind Turbines Using STATCOM

    DEFF Research Database (Denmark)

    Sun, Tao; Chen, Zhe; Blaabjerg, Frede

    2004-01-01

    to the point of common coupling (PCC) to relieve the flicker produced by grid connected wind turbines and the corresponding control scheme is described in detail. Simulation results show that STATCOM is an effective measure to mitigate the flicker level during continuous operation of grid connected wind......Grid connected wind turbines may produce flicker during continuous operation. In this paper flicker emission of grid connected wind turbines with doubly fed induction generators is investigated during continuous operation. A STATCOM using PWM voltage source converter (VSC) is connected in shunt...

  18. Thin grain oriented electrical steel for PWM voltages fed magnetic cores

    Directory of Open Access Journals (Sweden)

    Thierry Belgrand

    2018-04-01

    Full Text Available This paper reports on performances of high permeability grain oriented electrical steel when used in association with power electronic switching devices. Loss measurement results obtained from the Epstein test, using sinusoidal or various PWM voltages in medium frequency range, show that for both studied thicknesses (HGO 0.23mm and HGO 0.18mm, comparing performances at a fixed induction level between the various situations may not be the most convenient method. The effect of magnetic domain refinement has been investigated. After having shown the interest of lowering the thickness, an alternative way of looking at losses is proposed that may help to design the magnetic core when it comes to the matter of reducing size in considering frequency and magnetization levels.

  19. Toward a reduced-wire readout system for ultrasound imaging.

    Science.gov (United States)

    Lim, Jaemyung; Arkan, Evren F; Degertekin, F Levent; Ghovanloo, Maysam

    2014-01-01

    We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply.

  20. Isolated Full Bridge Boost DC-DC Converter Designed for Bidirectional Operation of Fuel Cells/Electrolyzer Cells in Grid-Tie Applications

    DEFF Research Database (Denmark)

    Pittini, Riccardo; Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    Energy production from renewable energy sources is continuously varying, for this reason energy storage is becoming more and more important as the percentage of green energy increases. Newly developed fuel cells can operate in reverse mode as electrolyzer cells; therefore, they are becoming...... current. Dc-dc converter efficiency plays a fundamental role in the overall system efficiency since processed energy is always flowing through the converter; for this reason, loss analysis and optimization are a key component of the converter design. The paper presents an isolated full bridge boost dc...

  1. Modulation and control of matrix converter for aerospace application

    Science.gov (United States)

    Kobravi, Keyhan

    In the context of modern aircraft systems, a major challenge is power conversion to supply the aircraft's electrical instruments. These instruments are energized through a fixed-frequency internal power grid. In an aircraft, the available sources of energy are a set of variable-speed generators which provide variable-frequency ac voltages. Therefore, to energize the internal power grid of an aircraft, the variable-frequency ac voltages should be converted to a fixed-frequency ac voltage. As a result, an ac to ac power conversion is required within an aircraft's power system. This thesis develops a Matrix Converter to energize the aircraft's internal power grid. The Matrix Converter provides a direct ac to ac power conversion. A major challenge of designing Matrix Converters for aerospace applications is to minimize the volume and weight of the converter. These parameters are minimized by increasing the switching frequency of the converter. To design a Matrix Converter operating at a high switching frequency, this thesis (i) develops a scheme to integrate fast semiconductor switches within the current available Matrix Converter topologies, i.e., MOSFET-based Matrix Converter, and (ii) develops a new modulation strategy for the Matrix Converter. This Matrix Converter and the new modulation strategy enables the operation of the converter at a switching-frequency of 40kHz. To provide a reliable source of energy, this thesis also develops a new methodology for robust control of Matrix Converter. To verify the performance of the proposed MOSFET-based Matrix Converter, modulation strategy, and control design methodology, various simulation and experimental results are presented. The experimental results are obtained under operating condition present in an aircraft. The experimental results verify the proposed Matrix Converter provides a reliable power conversion in an aircraft under extreme operating conditions. The results prove the superiority of the proposed Matrix

  2. Multilevel Modular Converter for VSC-HVDC Transmission Applications: Control and Operational Aspects

    DEFF Research Database (Denmark)

    Gnanarathna, Udana N.; Gole, Aniruddha M.; Chaudhary, Sanjay Kumar

    2010-01-01

    Control methods for a new class of converter, the multilevel modular converter (MMC), recently introduced for HVDC transmission are discussed. The paper discusses converter-level controls including firing pulse generation and capacitor voltage balancing. It also covers higher level controls...... for incorporating the converter into a larger power network, with a weak ac receiving end. The performance behavior is studied using electromagnetic transients simulation....

  3. A high-performance stand-alone solar PV power system for LED lighting

    KAUST Repository

    Huang, B. J.

    2010-06-01

    The present study developed a high-performance solar PV power technology for the LED lighting of a solar home system. The nMPPO (near-Maximum-Power- Point- Operation) design is employed in system design to eliminate MPPT. A feedback control system using pulse width modulation (PWM) technique was developed for battery charging control which can increase the charging capacity by 78%. For high-efficiency lighting, the LED is directly driven by battery using a PWM discharge control to eliminate a DC/DC converter. Two solar-powered LED lighting systems (50W and 100W LED) were built. The long-term outdoor tests have shown that the loss of load probability for full-night lighting requirement is zero for 50W LED and 3.6% for 100W LED. © 2010 IEEE.

  4. Transformerless dc-Isolated Converter

    Science.gov (United States)

    Rippel, Wally E.

    1987-01-01

    Efficient voltage converter employs capacitive instead of transformer coupling to provide dc isolation. Offers buck/boost operation, minimal filtering, and low parts count, with possible application in photovoltaic power inverters, power supplies and battery charges. In photovoltaic inverter circuit with transformerless converter, Q2, Q3, Q4, and Q5 form line-commutated inverter. Switching losses and stresses nil because switching performed when current is zero.

  5. Generalized Switched-Inductor Based Buck-Boost Z-H Converter

    Directory of Open Access Journals (Sweden)

    E. Babaei

    2017-12-01

    Full Text Available In this paper, a generalized buck-boost Z-H converter based on switched inductors is proposed. This structure consists of a set of series connected switched-inductor cells. The voltage conversion ratio of the proposed structure is adjusted by changing the number of cells and the duty cycle. Like the conventional Z-H converter, the shoot-through switching state and the diode before LC network are eliminated. The proposed converter can provide high voltage gain in low duty cycles. Considering different values for duty cycle, the proposed structure works in two operating zones. In the first operating zone, it works as a buck-boost converter and in the second operating zone, it works as a boost converter. In this paper, a complete analysis of the proposed converter is presented. In order to confirm the accuracy of mathematic calculations, the simulations results by using PSCAD/EMTDC software are given.

  6. A three-port direct current converter

    DEFF Research Database (Denmark)

    2016-01-01

    circuit comprises a connection between the at least one input direct current source and the at least one storage battery, the primary side circuit configured for operating as a buck converter; a second magnetic component serially coupled to the first single magnetic component, wherein the first and second...... magnetic components are configured to perform a voltage step-up, wherein the secondary side circuit comprises a connection between the at least one storage battery and at least one load, the secondary side configured for operating as a tapped boost converter; wherein the three-port direct current converter......The three-port direct current converter comprising: at least one input direct current source; at least one storage battery; a primary side circuit; a secondary side circuit; a first single magnetic component shared by the primary side circuit and the secondary side circuit, wherein the primary side...

  7. Development of Digital Hysteresis Current Control with PLL Loop Gain Compensation Strategy for PWM Inverters with Constant Switching Frequency

    Directory of Open Access Journals (Sweden)

    N. Belhaouchet

    2008-03-01

    Full Text Available Hysteresis current control is one of the simplest techniques used to control the magnitude and phase angle of motor current for motor drives systems. However, this technique presents several disadvantages such as operation at variable switching frequency which can reveal problems of filtering, interference between the phases in the case of the three-phase systems with insulated neutral connection or delta connection, and irregularity of the modulation pulses which especially causes an acoustic noise on the level of the machine for the high power drive. In this paper, a new technique is proposed for a variable-hysteresis-band controller based on dead beat control applied to three phase voltage source PWM inverters feeding AC motors. Its main aim is firstly ensure a constant switching frequency and secondly the synchronization of modulation pulses using the phase-locked-loop with loop gain compensation in order to ensure a better stability. The behavior of the proposed technique is verified by simulation.

  8. Enhanced Control for Improving the Operation of Grid-Connected Power Converters under Faulty and Saturated Conditions

    Directory of Open Access Journals (Sweden)

    Mahdi Shahparasti

    2018-02-01

    Full Text Available In renewable energy based systems Grid-Connected Voltage Source Converters (GC-VSC are used in many applications as grid-feeding converters, which transfer the power coming from the renewable energy sources to the grid. In some cases, the operation of GC-VSC may become unstable or uncontrollable due to, among others: a grid fault or an inappropriate current-power reference, that give rise to fast electrical transients or a saturation of the controller. In this paper, an improved control scheme is proposed to enhance the controllability of GC-VSC in all these situations. This solution consists of two parts, on the one hand a new Proportional-Resonant (PR controller with anti-windup capability to be used as current controller, and secondly a new current/power reference modifier, which defines the suitable reactive current/power reference to keep the system stable. It is worth to mention that the proposed scheme does not need information about the grid parameters as it only uses the converter current, and the voltage at the capacitors of Inductor-Capacitor (LC output filter.

  9. A Signal-Interleaving Complex Bandpass Sigma-Delta Converter

    DEFF Research Database (Denmark)

    Wad, Paul Emmanuel

    1997-01-01

    Complex or quadrature Sigma-Delta converters operate on complex signals, i.e. signals consisting of a real and an imaginary component, whereas conventional converters operate only on real signals. The advantage of complex signal processing in the discrete-time domain is that the entire sampling...

  10. Free-piston Stirling component test power converter

    Science.gov (United States)

    Dochat, George; Dhar, Manmohan

    1991-01-01

    The National Aeronautics and Space Administration (NASA) has been evaluating free-piston Stirling power converters (FPSPCs) for use on a wide variety of space missions. They provide high reliability, long life, and efficient operation and can be coupled with all potential heat sources, various heat input and heat rejection systems, and various power management and distribution systems. FPSPCs can compete favorably with alternative power conversion systems over a range of hundreds of watts to megawatts. Mechanical Technology Incorporated (MTI) is developing FPSPC technology under contract to NASA Lewis Research Center and will demonstrate this technology in two full-scale power converters operating at space temperature conditions. The testing of the first of these, the component test power converter (CTPC), was initiated in Spring 1991 to evaluate mechanical operation at space operating temperatures. The CTPC design, hardware fabrication, and initial test results are reviewed.

  11. Flexible operation of parallel grid-connecting converters under unbalanced grid voltage

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    -link voltage ripple, and overloading. Moreover, under grid voltage unbalance, the active power delivery ability is decreased due to the converter's current rating limitation. In this paper, a thorough study on the current limitation of the grid-connecting converter under grid voltage unbalance is conducted....... In addition, based on the principle that total output active power should be oscillation free, a coordinated control strategy is proposed for the parallel grid-connecting converters. The case study has been conducted to demonstrate the effectiveness of this proposed control strategy....

  12. Electric current - frequency converter

    International Nuclear Information System (INIS)

    Kumahara, Tadashi; Kinbana, Setsuro.

    1967-01-01

    Herein disclosed is an improved simple electric current-frequency converter, the input current and output frequency linearity of which is widened to a range of four to five figures while compensating, for temperature. The converter may be used for computor processing and for telemetering the output signals from a nuclear reactor. The converter is an astable multivibrator which includes charging circuits comprising emitter-voltage compensated NPN transistors, a charged voltage detecting circuit of temperature compensated field effect transistors, and a transistor switching circuit for generating switching pulses independent of temperature. The converter exhibited a 0.7% frequency change within a range of 5 - 45 0 C and less than a 0.1% frequency drift after six hours of operation when the input current was maintained constant. (Yamaguchi, T.)

  13. Multilevel Converter by Cascading Two-Level Three-Phase Voltage Source Converter

    Directory of Open Access Journals (Sweden)

    Abdullrahman A. Al-Shamma’a

    2018-04-01

    Full Text Available This paper proposes a topology using isolated, cascaded multilevel voltage source converters (VSCs and employing two-winding magnetic elements for high-power applications. The proposed topology synthesizes 6 two-level, three-phase VSCs, so the power capability of the presented converter is six times the capability of each VSC module. The characteristics of the proposed topology are demonstrated through analyzing its current relationships, voltage relationships and power capability in detail. The power rating is equally shared among the VSC modules without the need for a sharing algorithm; thus, the converter operates as a single three-phase VSC. The comparative analysis with classical neutral-point clamped, flying capacitor and cascaded H-bridge exhibits the superior features of fewer insulated gate bipolar transistors (IGBTs, capacitor requirement and fewer diodes. To validate the theoretical performance of the proposed converter, it is simulated in a MATLAB/Simulink environment and the results are experimentally demonstrated using a laboratory prototype.

  14. Development of a wind converter and investigation of its operational function. Part 1: Technical description of the wind energy converter

    Science.gov (United States)

    Molly, J. P.; Steinheber, R.

    1982-11-01

    A 10 kW wind energy converter was developed by using as far possible standard serial production parts. The design criteria and the description of the essential machinery components of the MODA 10 wind energy converter are discussed. For some special load cases the safety calculation of the important components is shown. The blade control system which qualified for small wind energy converters, is explained. Weight and cost of the MODA 10 are considered.

  15. The Three-Phase Power Router and Its Operation with Matrix Converter toward Smart-Grid Applications

    Directory of Open Access Journals (Sweden)

    Alexandros Kordonis

    2015-04-01

    Full Text Available A power router has been recently developed for both AC and DC applications that has the potential for smart-grid applications. This study focuses on three-phase power switching through the development of an experimental setup which consists of a three-phase direct AC/AC matrix converter with a power router attached to its output. Various experimental switching scenarios with the loads connected to different input sources were investigated. The crescent introduction of decentralized power generators throughout the power-grid obligates us to take measurements for a better distribution and management of the power. Power routers and matrix converters have great potential to succeed this goal with the help of power electronics devices. In this paper, a novel experimental three-phase power switching was achieved and the advantages of this operation are presented, such as on-demand and constant power supply at the desired loads.

  16. AUTOMOTIVE DIESEL MAINTENANCE 2. UNIT V, AUTOMATIC TRANSMISSIONS--TORQUE CONVERTER.

    Science.gov (United States)

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF TORQUE CONVERTERS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) FLUID COUPLINGS (LOCATION AND PURPOSE), (2) PRINCIPLES OF OPERATION, (3) TORQUE CONVERRS, (4) TORQMATIC CONVERTER, (5) THREE STAGE, THREE ELEMENT TORQUE CONVERTER, AND (6)…

  17. Improving Power Converter Reliability

    DEFF Research Database (Denmark)

    Ghimire, Pramod; de Vega, Angel Ruiz; Beczkowski, Szymon

    2014-01-01

    of a high-power IGBT module during converter operation, which may play a vital role in improving the reliability of the power converters. The measured voltage is used to estimate the module average junction temperature of the high and low-voltage side of a half-bridge IGBT separately in every fundamental......The real-time junction temperature monitoring of a high-power insulated-gate bipolar transistor (IGBT) module is important to increase the overall reliability of power converters for industrial applications. This article proposes a new method to measure the on-state collector?emitter voltage...... is measured in a wind power converter at a low fundamental frequency. To illustrate more, the test method as well as the performance of the measurement circuit are also presented. This measurement is also useful to indicate failure mechanisms such as bond wire lift-off and solder layer degradation...

  18. AC Voltage Control of DC/DC Converters Based on Modular Multilevel Converters in Multi-Terminal High-Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Rui Li

    2016-12-01

    Full Text Available The AC voltage control of a DC/DC converter based on the modular multilevel converter (MMC is considered under normal operation and during a local DC fault. By actively setting the AC voltage according to the two DC voltages of the DC/DC converter, the modulation index can be near unity, and the DC voltage is effectively utilized to output higher AC voltage. This significantly decreases submodule (SM capacitance and conduction losses of the DC/DC converter, yielding reduced capital cost, volume, and higher efficiency. Additionally, the AC voltage is limited in the controllable range of both the MMCs in the DC/DC converter; thus, over-modulation and uncontrolled currents are actively avoided. The AC voltage control of the DC/DC converter during local DC faults, i.e., standby operation, is also proposed, where only the MMC connected on the faulty cable is blocked, while the other MMC remains operational with zero AC voltage output. Thus, the capacitor voltages can be regulated at the rated value and the decrease of the SM capacitor voltages after the blocking of the DC/DC converter is avoided. Moreover, the fault can still be isolated as quickly as the conventional approach, where both MMCs are blocked and the DC/DC converter is not exposed to the risk of overcurrent. The proposed AC voltage control strategy is assessed in a three-terminal high-voltage direct current (HVDC system incorporating a DC/DC converter, and the simulation results confirm its feasibility.

  19. Design and Implementation of Battery Charger with Power Factor Correction using Sepic Converter and Full-bridge DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Moh. Zaenal Efendi

    2013-12-01

    Full Text Available This paper presents a design and implementation of a converter which has a high power factor for battery charger application. The converter is a combination of a SEPIC converter and a full-bridge DC-DC converter connected in two stages of series circuit. The SEPIC converter works in discontinuous conduction mode and it serves as a power factor corrector so that the shape of input current waveform follows the shape of input voltage waveform. The full-bridge DC-DC converter serves as a regulator of output voltage and operates at continuous conduction mode. The experimental results show that the power factor of this converter system can be achieved up to 0.96.

  20. Optimal Constant DC Link Voltage Operation of aWave Energy Converter

    Directory of Open Access Journals (Sweden)

    Mats Leijon

    2013-04-01

    Full Text Available This article proposes a simple and reliable damping strategy for wave powerfarm operation of small-scale point-absorber converters. The strategy is based on passiverectification onto a constant DC-link, making it very suitable for grid integration of the farm.A complete model of the system has been developed in Matlab Simulink, and uses real sitedata as input. The optimal constant DC-voltage is evaluated as a function of the significantwave height and energy period of the waves. The total energy output of the WEC is derivedfor one year of experimental site data. The energy output is compared for two cases, onewhere the optimal DC-voltage is determined and held constant at half-hour basis throughoutthe year, and one where a selected value of the DC-voltage is kept constant throughout theyear regardless of sea state.

  1. Junction temperature estimation method for a 600 V, 30A IGBT module during converter operation

    DEFF Research Database (Denmark)

    Choi, U. M.; Blaabjerg, F.; Iannuzzo, F.

    2015-01-01

    This paper proposes an accurate method to estimate the junction temperature using the on-state collector-emitter voltage at high current. By means of the proposed method, the estimation error which comes from the different temperatures of the interconnection materials in the module is compensated....... Finally, it leads to satisfactory estimated results. The proposed method has been verified by means of an IR (Infra-Red) camera during power converter operations when the loading current is sinusoidal....

  2. One-Stage and Two-Stage Schemes of High Performance Synchronous PWM with Smooth Pulses-Ratio Changing

    DEFF Research Database (Denmark)

    Oleschuk, V.; Blaabjerg, Frede

    2002-01-01

    This paper presents detailed description of one-stage and two-stage schemes of a novel method of synchronous, pulsewidth modulation (PWM) for voltage source inverters for ac drive application. The proposed control functions provide accurate realization of different versions of voltage space vector...... modulation with synchronization of the voltage waveform of the inverter and with smooth pulse-ratio changing. Voltage spectra do not contain even harmonic and sub-harmonics (combined harmonics) during the whole control range including the zone of overmodulation. Examples of determination of the basic control...

  3. State of Charge Balancing Control of a Multi-Functional Battery Energy Storage System Based on a 11-Level Cascaded Multilevel PWM Converter

    DEFF Research Database (Denmark)

    Wang, Songcen; Teodorescu, Remus; Máthé, Lászlo

    2015-01-01

    This paper focuses on modeling and SOC (State of Charge) balancing control of lithium-ion battery energy storage system based on cascaded multilevel converter for both grid integration and electric vehicle propulsion applications. The equivalent electrical circuit model of lithium-ion battery...

  4. A new method of converter transformer protection without commutation failure

    Science.gov (United States)

    Zhang, Jiayu; Kong, Bo; Liu, Mingchang; Zhang, Jun; Guo, Jianhong; Jing, Xu

    2018-01-01

    With the development of AC / DC hybrid transmission technology, converter transformer as nodes of AC and DC conversion of HVDC transmission technology, its reliable safe and stable operation plays an important role in the DC transmission. As a common problem of DC transmission, commutation failure poses a serious threat to the safe and stable operation of power grid. According to the commutation relation between the AC bus voltage of converter station and the output DC voltage of converter, the generalized transformation ratio is defined, and a new method of converter transformer protection based on generalized transformation ratio is put forward. The method uses generalized ratio to realize the on-line monitoring of the fault or abnormal commutation components, and the use of valve side of converter transformer bushing CT current characteristics of converter transformer fault accurately, and is not influenced by the presence of commutation failure. Through the fault analysis and EMTDC/PSCAD simulation, the protection can be operated correctly under the condition of various faults of the converter.

  5. DESIGN OPTIMIZATION OF RESONANT DC-DC CONVERTERS

    OpenAIRE

    Belqasem Aljafari

    2016-01-01

    Resonant DC/DC converters are the class of converters, which have L-C resonant tank serving as a major part of the power conversion process. The fundamental concept of the resonant converter is that the circulating energy in an L-C resonant circuit is manageable by changing the operating frequency, and therefore the converter can condition the input power to the desired output voltage. The development in power conversion technology is steady demand for high power efficiency and high power den...

  6. Using variable DC sources in order to improve the voltage quality of a multilevel STATCOM with low frequency modulation

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Najjar, Mohammad; Blaabjerg, Frede

    2016-01-01

    In this paper, a Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) method, which utilizes adjustable dc links, is presented for a Static Synchronous Compensator (STATCOM) based on Cascaded H-Bridge (CHB) multilevel converter. The proposed switching algorithm is able to fix the capac......In this paper, a Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) method, which utilizes adjustable dc links, is presented for a Static Synchronous Compensator (STATCOM) based on Cascaded H-Bridge (CHB) multilevel converter. The proposed switching algorithm is able to fix...... unequal dc link voltages more levels at the output is achievable compared to the symmetrical multilevel converters that could be used in enhancing the power quality, while keeping the switching frequency near the fundamental (the maximum switching frequency can be kept below 150 Hz). The validity...

  7. Multi-stage LLC resonant converters designed for wide output voltage ranges

    OpenAIRE

    Tsang, C.-W.; Bingham, C. M.; Foster, M. P.; Stone, D. A.; Leech, J. M.

    2016-01-01

    The paper describes a novel multi-stage LLC resonant converter topology for facilitating wide output voltage ranges. This is achieved by combining the gain range of a capacitor-diode clamped LLC resonant converter with that of a traditional LLC resonant converter. A prototype converter is designed and commissioned to illustrate the design procedure and demonstrate resulting operational characteristics. Experimental results are used to show operational characteristics of the proposed conver...

  8. Amplitude-to-code converter for photomultipliers operating at high loadings

    International Nuclear Information System (INIS)

    Arkhangel'skij, B.V.; Evgrafov, G.N.; Pishchal'nikov, Yu.M.; Shuvalov, R.S.

    1982-01-01

    An 11-bit amplitude-to-code converter intended for the analysis of photomultiplier pulses under high loadings is described. To decrease the volume of digit electronics in the converter an analog memory on capacities is envisaged. A well-known bridge circuit with diodes on the main carriers is selected as a gating circuit. The gate control is realized by a switching circuit on fast-response transistors with boundary frequency of 1.2-1.5 GHz. The converter main characteristics are given, namely, maximum output signal amplitude equal to -1.5 V, minimum pulse selection duration of 10 ns, maximum number of counts at Usub(input)=-1.0 V and tsub(selection)=50 ns amounting to 1400, integral nonlinearity of +-0.1%, conversion temperature instability of 0.2%/deg C in the temperature range of (+10-+40) deg C, maximum time of data storage equal to 300 ms, conversion coefficient instability of 0.42 counts, number of channels in a unit CAMAC block equal to 12

  9. Unregulated Series Resonant Converter for Interlinking DC Nanogrids

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Zhang, Zhe; Ouyang, Ziwei

    2017-01-01

    bidirectional converter to interlink a 400V DC bus with a 48V DC bus ispresented. The proposed converter is based on a LLC resonant converter operating as a DC transformer at a fixed frequency and duty cycle without any complex control strategy. A clearand simplified design procedure for high efficiency...

  10. Converter applications and their influence on large electrical machines

    CERN Document Server

    Drubel, Oliver

    2013-01-01

    Converter driven applications are applied in more and more processes. Almost any installed wind-farm, ship drives, steel mills, several boiler feed water pumps, extruder and many other applications operate much more efficient and economic in case of variable speed solutions. The boundary conditions for a motor or generator will change, if it is supplied by a converter. An electrical machine, which is operated by a converter, can no longer be regarded as an independent component, but is embedded in a system consisting of converter and machine. This book gives an overview of existing converter designs for large electrical machines. Methods for the appropriate calculation of machine phenomena, which are implied by converters are derived in the power range above 500kVA. It is shown how due to the converter inherent higher voltage harmonics and pulse frequencies special phenomena are caused inside the machine which can be the reason for malfunction. It is demonstrated that additional losses create additional tempe...

  11. High-frequency matrix converter with square wave input

    Science.gov (United States)

    Carr, Joseph Alexander; Balda, Juan Carlos

    2015-03-31

    A device for producing an alternating current output voltage from a high-frequency, square-wave input voltage comprising, high-frequency, square-wave input a matrix converter and a control system. The matrix converter comprises a plurality of electrical switches. The high-frequency input and the matrix converter are electrically connected to each other. The control system is connected to each switch of the matrix converter. The control system is electrically connected to the input of the matrix converter. The control system is configured to operate each electrical switch of the matrix converter converting a high-frequency, square-wave input voltage across the first input port of the matrix converter and the second input port of the matrix converter to an alternating current output voltage at the output of the matrix converter.

  12. Experimental Results of a DC Bus Voltage Level Control for a Load-Controlled Marine Current Energy Converter

    Directory of Open Access Journals (Sweden)

    Johan Forslund

    2015-05-01

    Full Text Available This paper investigates three load control methods for a  marine current energy converter using a vertical axis current  turbine (VACT mounted on a permanent magnet synchronous generator  (PMSG. The three cases are; a fixed AC load, a fixed pulse width  modulated (PWM DC load and DC bus voltage control of a DC  load. Experimental results show that the DC bus voltage control  reduces the variations of rotational speed by a factor of 3.5 at the cost  of slightly increased losses in the generator and transmission lines.  For all three cases, the tip speed ratio \\(\\lambda\\ can be kept close to  the expected \\(\\lambda_{opt}\\. The power coefficient is estimated to be  0.36 at \\(\\lambda_{opt}\\; however, for all three cases, the average  extracted power was about \\(\\sim 19\\\\%. A maximum power point  tracking (MPPT system, with or without water velocity measurement,  could increase the average extracted power.

  13. Development of residential solar air conditioning system for electricity power peak cut 3

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Gwon Jong [Korea Inst. of Energy and Resources, Daeduk (Korea, Republic of)

    1995-12-31

    In this research, the converter rectifier unit of the inverter air conditioner is substituted into the bidirectional PWM converter. The DC/DC power converter is established on the DC link between the photovoltaic array and the inverter air conditioner, and the photovoltaic air conditioning system which can be parallel driven which utility is developed. (author). 35 ref., 112 figs.

  14. Controller for a wave energy converter

    Science.gov (United States)

    Wilson, David G.; Bull, Diana L.; Robinett, III, Rush D.

    2015-09-22

    A wave energy converter (WEC) is described, the WEC including a power take off (PTO) that converts relative motion of bodies of the WEC into electrical energy. A controller controls operation of the PTO, causing the PTO to act as a motor to widen a wave frequency spectrum that is usable to generate electrical energy.

  15. Simulation and analysis of an isolated full-bridge DC/DC boost converter operating with a modified perturb and observe maximum power point tracking algorithm

    Directory of Open Access Journals (Sweden)

    Calebe A. Matias

    2017-07-01

    Full Text Available The purpose of the present study is to simulate and analyze an isolated full-bridge DC/DC boost converter, for photovoltaic panels, running a modified perturb and observe maximum power point tracking method. The zero voltage switching technique was used in order to minimize the losses of the converter for a wide range of solar operation. The efficiency of the power transfer is higher than 90% for large solar operating points. The panel enhancement due to the maximum power point tracking algorithm is 5.06%.

  16. Resonance propagation of parallel-operated DC-AC converters with LCL filters

    DEFF Research Database (Denmark)

    Lu, Xiaonan; Liserre, Marco; Sun, Kai

    2012-01-01

    filter has higher power density, its resonance problem should be noticed. In a large renewable energy farm, multiple converters inside are connected in parallel. In this way, the analysis of the resonance problem should be expanded. Compared to a conventional single LCL filter system, additional...... performance is also influenced. In this paper, the resonance propagation of parallel converter system with a local capacitor for reactive power compensation is analyzed in detail. Simulation and experiment results support the theoretical analyses.......With the higher penetration of renewable energy into modern power system, power electronics converters are most commonly employed as the interfaces to the grid. At the same time, to deal with high frequency harmonic components, LCL filters are usually adopted. Although compared to L-filters, LCL...

  17. A study of Schwarz converters for nuclear powered spacecraft

    Science.gov (United States)

    Stuart, Thomas A.; Schwarze, Gene E.

    1987-01-01

    High power space systems which use low dc voltage, high current sources such as thermoelectric generators, will most likely require high voltage conversion for transmission purposes. This study considers the use of the Schwarz resonant converter for use as the basic building block to accomplish this low-to-high voltage conversion for either a dc or an ac spacecraft bus. The Schwarz converter has the important assets of both inherent fault tolerance and resonant operation; parallel operation in modular form is possible. A regulated dc spacecraft bus requires only a single stage converter while a constant frequency ac bus requires a cascaded Schwarz converter configuration. If the power system requires constant output power from the dc generator, then a second converter is required to route unneeded power to a ballast load.

  18. Understanding delta-sigma data converters

    CERN Document Server

    Pavan, Shanti; Temes, Gabor C

    2017-01-01

    This new edition introduces novel analysis and design techniques for delta-sigma (ΔΣ) converters in physical and conceptual terms, and includes new chapters that explore developments in the field over the last decade. This book explains the principles and operation of delta-sigma analog-to-digital converters (ADCs) in physical and conceptual terms in accordance with the most recent developments in the field. The interest of ΔΣ converter designers has shifted significantly over the past decade, due to many new applications for data converters at the far ends of the frequency spectrum. Continuous-time delta-sigma A/D converters with GHz clocks, of both lowpass and bandpass types, are required for wireless applications. At the other extreme, multiplexed ADCs with very narrow (sometimes 10 Hz wide) signal bandwidths, but very high accuracy are needed in the interfaces of biomedical and environmental sensors. To reflect the changing eeds of designers, the second edition includes significant new material on bo...

  19. A new interleaved double-input three-level boost converter

    DEFF Research Database (Denmark)

    Chen, Jianfei; Hou, Shiying; Sun, Tao

    2016-01-01

    This paper proposes a new interleaved double-input three-level Boost (DITLB) converter, which is composed of two boost converters indirectly in series. Thus, a high voltage gain, together with a low component stress and a small input current ripple due to the interleaved control scheme, is achieved....... The operating principle of the DITLB converter under the individual supplying power (ISP) and simultaneous supplying power (SSP) mode is analyzed. In addition, closed-loop control strategies composed of a voltage-current loop and a voltage-balance loop, have been researched to make the converter operate...... steadily and to alleviate the neutral-point imbalance issue. Experimental results verify correctness and feasibility of the proposed topology and control strategies....

  20. State-plane analysis of parallel resonant converter

    Science.gov (United States)

    Oruganti, R.; Lee, F. C.

    1985-01-01

    A method for analyzing the complex operation of a parallel resonant converter is developed, utilizing graphical state-plane techniques. The comprehensive mode analysis uncovers, for the first time, the presence of other complex modes besides the continuous conduction mode and the discontinuous conduction mode and determines their theoretical boundaries. Based on the insight gained from the analysis, a novel, high-frequency resonant buck converter is proposed. The voltage conversion ratio of the new converter is almost independent of load.

  1. Current-to-frequency converter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W [Institute of Nuclear Research, Warsaw (Poland)

    1981-07-15

    A current-to-frequency converter covering the range from 3 x 10/sup -10/ A up to 3 x 10/sup -5/ A of the input current is described. The circuit operates with nuclear detectors featuring a high internal resistance.

  2. Vector control of three-phase AC/DC front-end converter

    Indian Academy of Sciences (India)

    Section 4 presents the simulation and experimental results of FEC. Section 5 discusses the problems associated with the starting process of ..... A 250-kVA vector-controlled FEC is simulated with MATLAB/SIMULINK. ..... Ghosh R 2007 Modelling, Analysis and Control of Single-phase and Three-phase PWM Rectifiers.

  3. New Multiphase Hybrid Boost Converter with Wide Conversion Ratio for PV System

    Directory of Open Access Journals (Sweden)

    Ioana-Monica Pop-Calimanu

    2014-01-01

    Full Text Available A new multiphase hybrid boost converter, with wide conversion ratio as a solution for photovoltaic energy system, is presented in this paper. To ensure that all the phases of the converter operate at the same switching frequency we use interleaving topology. The proposed converter can be used as an interface between the PV system and the DC load/inverter. This multiphase converter has the advantage of reduced value and physical size of the input and output capacitor as well as the effort for the inductors. To validate the operation of the converter we provide the analyses and the simulation results of the converter.

  4. Analytical Model for LLC Resonant Converter With Variable Duty-Cycle Control

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Blaabjerg, Frede

    2016-01-01

    are identified and discussed. The proposed model enables a better understanding of the operation characteristics and fast parameter design of the LLC converter, which otherwise cannot be achieved by the existing simulation based methods and numerical models. The results obtained from the proposed model......In LLC resonant converters, the variable duty-cycle control is usually combined with a variable frequency control to widen the gain range, improve the light-load efficiency, or suppress the inrush current during start-up. However, a proper analytical model for the variable duty-cycle controlled LLC...... converter is still not available due to the complexity of operation modes and the nonlinearity of steady-state equations. This paper makes the efforts to develop an analytical model for the LLC converter with variable duty-cycle control. All possible operation models and critical operation characteristics...

  5. The Fault Detection, Localization, and Tolerant Operation of Modular Multilevel Converters with an Insulated Gate Bipolar Transistor (IGBT Open Circuit Fault

    Directory of Open Access Journals (Sweden)

    Wei Li

    2018-04-01

    Full Text Available Reliability is one of the critical issues for a modular multilevel converter (MMC since it consists of a large number of series-connected power electronics submodules (SMs. In this paper, a complete control strategy including fault detection, localization, and tolerant operation is proposed for the MMC under an insulated gate bipolar transistor (IGBT open circuit fault. According to the output characteristics of the SM with the open-circuit fault of IGBT, a fault detection method based on the circulating current and output current observation is used. In order to further precisely locate the position of the faulty SM, a fault localization method based on the SM capacitor voltage observation is developed. After the faulty SM is isolated, the continuous operation of the converter is ensured by adopting the fault-tolerant strategy based on the use of redundant modules. To verify the proposed fault detection, fault localization, and fault-tolerant operation strategies, a 900 kVA MMC system under the conditions of an IGBT open circuit is developed in the Matlab/Simulink platform. The capabilities of rapid detection, precise positioning, and fault-tolerant operation of the investigated detection and control algorithms are also demonstrated.

  6. A review of Indirect Matrix Converter Topologies

    Directory of Open Access Journals (Sweden)

    Salem Rahmani

    2015-08-01

    Full Text Available Abstract—Matrix Converter (MC is a modern direct AC/AC electrical power converter without dc-link capacitor. MC is operated in four quadrant, assuring a control of the output voltage, amplitude and frequency. The matrix converter has recently attracted significant attention among researchers and it has become increasing attractive for applications of wind energy conversion, military power supplies, induction motor drives, etc. Recently, different MC topologies have been proposed and developed which have their own advantages and disadvantages. Matrix converter can be classified as direct and indirect structures. The direct one has been elaborated in previous work. In this paper the indirect MCs are reviewed. Different characteristics of the indirect MC topologies are mentioned to show the strengths and weaknesses of such converter topologies.

  7. Underwater noise from a wave energy converter

    DEFF Research Database (Denmark)

    Tougaard, Jakob

    A recent addition to the anthropogenic sources of underwater noise is offshore wave energy converters. Underwater noise was recorded from the Wavestar wave energy converter located at Hastholm, Denmark (57°7.73´N, 8°37.23´E). The Wavestar is a full-scale test and demonstration converter...... in full operation and start and stop of the converter. Median broad band (10 Hz – 20 kHz) sound pressure level (Leq) was 123 dB re. 1 Pa, irrespective of status of the wave energy converter (stopped, running or starting/stopping). The most pronounced peak in the third-octave spectrum was in the 160 Hz...... significant noise above ambient could be detected above the 250 Hz band. The absolute increase in noise above ambient was very small. L50 third-octave levels in the four bands with the converter running were thus only 1-2 dB above ambient L50 levels. The noise recorded 25 m from the wave energy converter...

  8. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    Science.gov (United States)

    Afiqah Zainal, Nurul; Sooi Tat, Chan; Ajisman

    2016-02-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's ou tput is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor.

  9. Converter Monitoring Unit for Retrofit of Wind Power Converters

    DEFF Research Database (Denmark)

    Rannestad, Bjorn; Maarbjerg, Anders Eggert; Frederiksen, Kristian

    2018-01-01

    A Converter Monitoring Unit (CMU), which will enable condition monitoring of wind turbine converters is presented in this paper. Reducing the cost of corrective maintenance by means of condition monitoring is a way of lowering Operation & Maintenance (O&M) costs for wind turbine systems....... The CMU must be able to detect a broad range of failure modes related to Insulated Gate Bipolar Transistor (IGBT) power modules and associated gate drives. IGBT collector-emitter on-state voltage (vceon) and current (ic) is sampled in the CMU and used for detection of emerging failures. A new method...... for compensation of unwanted inductive voltage drop in the vceon measurement path is presented, enabling retrofitting of CMUs in existing wind turbines. Finally, experimental results obtained on a prototype CMU are presented. Experimentally the vceon dependency to IGBT junction temperature and deterioration...

  10. Li-Po Battery Charger Based on the Constant Current/Voltage Parallel Resonant Converter Operating in ZVS

    Directory of Open Access Journals (Sweden)

    Alberto M. Pernía

    2018-04-01

    Full Text Available Battery requirements for electrical vehicles are continuously becoming more demanding in terms of energy density and reliability. Nowadays, batteries for drones must be able to supply 100 A for 15 min, not to mention the specifications required for batteries in electrical vehicles. These specifications result in more stringent specifications for battery chargers. They are required to be more efficient, flexible, and, as with any another power equipment, to have reduced size and weight. Since the parallel resonant converter can operate as a current source and as a voltage source, this paper presents a battery charger power stage for lithium ion polymer batteries, based on the above topology, operating in zero voltage switching mode, and implementing frequency and duty cycle control.

  11. Passive Resonant Bidirectional Converter with Galvanic Barrier

    Science.gov (United States)

    Rosenblad, Nathan S. (Inventor)

    2014-01-01

    A passive resonant bidirectional converter system that transports energy across a galvanic barrier includes a converter using at least first and second converter sections, each section including a pair of transfer terminals, a center tapped winding; a chopper circuit interconnected between the center tapped winding and one of the transfer terminals; an inductance feed winding interconnected between the other of the transfer terminals and the center tap and a resonant tank circuit including at least the inductance of the center tap winding and the parasitic capacitance of the chopper circuit for operating the converter section at resonance; the center tapped windings of the first and second converter sections being disposed on a first common winding core and the inductance feed windings of the first and second converter sections being disposed on a second common winding core for automatically synchronizing the resonant oscillation of the first and second converter sections and transferring energy between the converter sections until the voltage across the pairs of transfer terminals achieves the turns ratio of the center tapped windings.

  12. Steady State Analysis of LCLC Resonant Converter with Capacitive Output Filter

    Directory of Open Access Journals (Sweden)

    Navid Shafiyi

    2010-01-01

    Full Text Available This paper presents the mathematical analysis and modeling of a 4th order LCLC resonant converter with capacitive output filter in steady-state condition. Due to the nonlinearity of the LCLC resonant circuit with capacitive output filter, the conventional modeling procedure cannot thoroughly describe the behavior of the converter. In this paper, a mathematical model is proposed that can accommodate the absence of the output inductor and predict the converter performance for a wide range of operating conditions. A 2.25KW prototype converter is provided to evaluate the accuracy of the proposed model. Experimental results show that the proposed model can precisely predict the behavior of the converter for a wide range of operating conditions.

  13. Continuously-stirred anaerobic digester to convert organic wastes into biogas: system setup and basic operation.

    Science.gov (United States)

    Usack, Joseph G; Spirito, Catherine M; Angenent, Largus T

    2012-07-13

    Anaerobic digestion (AD) is a bioprocess that is commonly used to convert complex organic wastes into a useful biogas with methane as the energy carrier. Increasingly, AD is being used in industrial, agricultural, and municipal waste(water) treatment applications. The use of AD technology allows plant operators to reduce waste disposal costs and offset energy utility expenses. In addition to treating organic wastes, energy crops are being converted into the energy carrier methane. As the application of AD technology broadens for the treatment of new substrates and co-substrate mixtures, so does the demand for a reliable testing methodology at the pilot- and laboratory-scale. Anaerobic digestion systems have a variety of configurations, including the continuously stirred tank reactor (CSTR), plug flow (PF), and anaerobic sequencing batch reactor (ASBR) configurations. The CSTR is frequently used in research due to its simplicity in design and operation, but also for its advantages in experimentation. Compared to other configurations, the CSTR provides greater uniformity of system parameters, such as temperature, mixing, chemical concentration, and substrate concentration. Ultimately, when designing a full-scale reactor, the optimum reactor configuration will depend on the character of a given substrate among many other nontechnical considerations. However, all configurations share fundamental design features and operating parameters that render the CSTR appropriate for most preliminary assessments. If researchers and engineers use an influent stream with relatively high concentrations of solids, then lab-scale bioreactor configurations cannot be fed continuously due to plugging problems of lab-scale pumps with solids or settling of solids in tubing. For that scenario with continuous mixing requirements, lab-scale bioreactors are fed periodically and we refer to such configurations as continuously stirred anaerobic digesters (CSADs). This article presents a general

  14. Efficiency and reliability improvement in wind turbine converters by grid converter adaptive control

    DEFF Research Database (Denmark)

    Trintis, Ionut; Munk-Nielsen, Stig; Abrahamsen, Flemming

    2013-01-01

    This paper presents a control method that reduces the losses in wind turbine converters adaptively controlling the grid converter. The dc-link voltage adapts its reference based on the system state and therefore reduces the stored energy, and is therefore kept at the minimum necessary for the grid...... and generator side. Operating in this way, the electrical and thermal stress factors are decreased on the power electronic devices, increasing their lifetime. The simulation results using this method show efficiency increase and devices temperature cycles slightly decreased. Experimental results on a wind...... turbine power stack shows efficiency increase in the high power region....

  15. Current Mode Control for LLC Series Resonant DC-to-DC Converters

    Directory of Open Access Journals (Sweden)

    Jinhaeng Jang

    2015-06-01

    Full Text Available Conventional voltage mode control only offers limited performance for LLC series resonant DC-to-DC converters experiencing wide variations in operational conditions. When the existing voltage mode control is employed, the closed-loop performance of the converter is directly affected by unavoidable changes in power stage dynamics. Thus, a specific control design optimized at one particular operating point could become unacceptable when the operational condition is varied. This paper presents a new current mode control scheme which could consistently provide good closed-loop performance for LLC resonant converters for the entire operational range. The proposed control scheme employs an additional feedback from the current of the resonant tank network to overcome the limitation of the existing voltage mode control. The superiority of the proposed current mode control over the conventional voltage mode control is verified using an experimental 150 W LLC series resonant DC-to-DC converter.

  16. State-plane analysis of zero-voltage-switching resonant dc/dc power converters

    Science.gov (United States)

    Kazimierczuk, Marian K.; Morse, William D.

    The state-plane analysis technique for the zero-voltage-switching resonant dc/dc power converter family of topologies, namely the buck, boost, buck-boost, and Cuk converters is established. The state plane provides a compression of information that allows the designer to uniquely examine the nonlinear dynamics of resonant converter operation. Utilizing the state plane, resonant converter modes of operation are examined and the switching frequencies are derived for the boundaries between these modes, including the boundary of energy conversion.

  17. Large step-down DC-DC converters with reduced current stress

    International Nuclear Information System (INIS)

    Ismail, Esam H.

    2009-01-01

    In this paper, several DC-DC converters with large voltage step-down ratios are introduced. A simple modification in the output section of the conventional buck and quadratic converters can effectively extend the duty-cycle range. Only two additional components (an inductor and diode) are necessary for extending the duty-cycle range. The topologies presented in this paper show an improvement in the duty-cycle (about 40%) over the conventional buck and quadratic converters. Consequently, they are well suited for extreme step-down voltage conversion ratio applications. With extended duty-cycle, the current stress on all components is reduced, leading to a significant improvement of the system losses. The principle of operation, theoretical analysis, and comparison of circuit performances with other step-down converters is discussed regarding voltage and current stress. Experimental results of one prototype rated 40-W and operating at 100 kHz are provided in this paper to verify the performance of this new family of converters. The efficiency of the proposed converters is higher than the quadratic converters

  18. Design of a high power, resonant converter for DC wind turbines

    DEFF Research Database (Denmark)

    Dincan, Catalin Gabriel; Kjær, Philip Carne; Chen, Yu-Hsing

    2018-01-01

    This paper presents a design procedure and loss estimation for a high power, medium voltage series resonant converter (entitled SRC#), intended for application in megawatt medium-voltage DC wind turbines. The converter is operated with a novel method of operation, entitled pulse removal technique...

  19. Ac-dc converter firing error detection

    International Nuclear Information System (INIS)

    Gould, O.L.

    1996-01-01

    Each of the twelve Booster Main Magnet Power Supply modules consist of two three-phase, full-wave rectifier bridges in series to provide a 560 VDC maximum output. The harmonic contents of the twelve-pulse ac-dc converter output are multiples of the 60 Hz ac power input, with a predominant 720 Hz signal greater than 14 dB in magnitude above the closest harmonic components at maximum output. The 720 Hz harmonic is typically greater than 20 dB below the 500 VDC output signal under normal operation. Extracting specific harmonics from the rectifier output signal of a 6, 12, or 24 pulse ac-dc converter allows the detection of SCR firing angle errors or complete misfires. A bandpass filter provides the input signal to a frequency-to-voltage converter. Comparing the output of the frequency-to-voltage converter to a reference voltage level provides an indication of the magnitude of the harmonics in the ac-dc converter output signal

  20. A Multifunctional Isolated and Non-Isolated Dual Mode Converter for Renewable Energy Conversion Applications

    Directory of Open Access Journals (Sweden)

    Yiwang Wang

    2017-11-01

    Full Text Available In this paper, a multifunctional isolated and non-isolated dual-mode low-power converter was designed for renewable energy conversion applications such as photovoltaic power generation to achieve different operating modes under bi-directional electrical conversion. The proposed topology consists of a bidirectional non-isolated DC/DC circuit and an isolated converter with a high-frequency transformer, which merge the advantages of both the conventional isolated converter and non-isolated converter with the combination of the two converter technologies. Compared with traditional converters, the multifunctional converter can not only realize conventional bi-directional functions, but can also be applied for many different operation modes and meet the high output/input ratio demands with the two converter circuits operating together. A novel control algorithm was proposed to achieve the various functions of the proposed converter. An experimental platform based on the proposed circuit was established. Both the simulation and experimental results indicated that the proposed converter could provide isolated and non-isolated modes in different applications, which could meet different practical engineering requirements.

  1. High voltage direct current transmission converters, systems and DC grids

    CERN Document Server

    Jovcic, Dragan

    2015-01-01

    This comprehensive reference guides the reader through all HVDC technologies, including LCC (Line Commutated Converter), 2-level VSC and VSC HVDC based on modular multilevel converters (MMC) for an in-depth understanding of converters, system level design, operating principles and modeling. Written in a tutorial style, the book also describes the key principles of design, control, protection and operation of DC transmission grids, which will be substantially different from the practice with AC transmission grids. The first dedicated reference to the latest HVDC technologies and DC grid developments; this is an essential resource for graduate students and researchers as well as engineers and professionals working on the design, modeling and operation of DC grids and HVDC.

  2. A Method of Maximum Power Control in Single-phase Utility Interactive Photovoltaic Generation System by using PWM Current Source Inverter

    Science.gov (United States)

    Neba, Yasuhiko

    This paper deals with a maximum power point tracking (MPPT) control of the photovoltaic generation with the single-phase utility interactive inverter. The photovoltaic arrays are connected by employing the PWM current source inverter to the utility. The use of the pulsating dc current and voltage allows the maximum power point to be searched. The inverter can regulate the array voltage and keep the arrays to the maximum power. This paper gives the control method and the experimental results.

  3. Active superconducting DC fault current limiter based on flux compensation

    International Nuclear Information System (INIS)

    Shi Jing; Tang Yuejin; Wang, Chen; Zhou Yusheng; Li Jingdong; Ren Li; Chen Shijie

    2006-01-01

    With the extensive application of DC power systems, suppression of DC fault current is an important subject that guarantees system security. This paper presents an active superconducting DC fault current limiter (DC-SFCL) based on flux compensation. The DC-SFCL is composed of two superconducting windings wound on a single iron core, the primary winding is in series with DC power system, and the second winding is connected with AC power system through a PWM converter. In normal operating state, the flux in the iron core is compensated to zero, and the SFCL has no influence on DC power system. In the case of DC system accident, through regulating the active power exchange between the SFCL's second winding and the AC power system, the current on the DC side can be limited to different level complying with the system demand. Moreover, the PWM converter that interface the DC system and AC system can be controlled as a reactive power source to supply voltage support for the AC side, which has little influence on the performance of SFCL. Using MATLAB SIMULINK, the mathematic model of the DC-SFCL is created, simulation results validate the dynamics of system, and the performance of DC-SFCL is confirmed

  4. A VHF Class E DC-DC Converter with Self-Oscillating Gate Driver

    DEFF Research Database (Denmark)

    Andersen, Toke Meyer; Christensen, Søren K.; Knott, Arnold

    2011-01-01

    , is inherently resonant, and switching losses are greatly reduced by ensuring Zero Voltage Switching (ZVS) of the power semiconductor devices. A design method to ensure ZVS operation when combining the inverter, rectifier, and gate driver is provided. Several parasitic effects and their influence on converter......This paper describes the analysis and design of a DC-DC converter topology which is operational at frequencies in the Very High Frequency (VHF) band ranging from 30 MHz − 300 MHz. The presented topology, which consists of a class E inverter, class E rectifier, and self-oscillating gate driver...... operation are discussed, and measurement results of a 100 MHz prototype converter are presented and evaluated. The designed prototype converter verifies the described topology....

  5. CAS - CERN Accelerator School: Power Converters

    CERN Document Server

    2015-01-01

    These proceedings collate lectures given at the twenty-eighth specialized course organised by the CERN Accelerator School (CAS). The course was held at the Hotel du Parc, Baden, Switzerland from 7 - 14 May 2014, in collaboration with the Paul Scherrer Institute. Following introductory lectures on accelerators and the requirements on power converters, the course covered components and topologies of the different types of power converters needed for particle accelerators. Issues of design, control and exploitation in a sometimes-hostile environment were addressed. Site visits to ABB and PSI provided an insight into state-of-the-art power converter production and operation, while topical seminars completed the programme.

  6. A complete dc characterization of a constant-frequency, clamped-mode, series-resonant converter

    Science.gov (United States)

    Tsai, Fu-Sheng; Lee, Fred C.

    1988-01-01

    The dc behavior of a clamped-mode series-resonant converter is characterized systematically. Given a circuit operating condition, the converter's mode of operation is determined and various circuit parameters are calculated, such as average inductor current (load current), rms inductor current, peak capacitor voltage, rms switch currents, average diode currents, switch turn-on currents, and switch turn-off currents. Regions of operation are defined, and various circuit characteristics are derived to facilitate the converter design.

  7. Regenerating method for thyristor converter used in AC inverter rolling stock; Koryu inverter sharyoyo thyristor converter no kaisei hoshiki no kento

    Energy Technology Data Exchange (ETDEWEB)

    Inarida, S.; Ito, S.; Nakamura, K. [Hitachi, Ltd., Tokyo (Japan)

    1995-09-20

    A thyristor converter is superior to GTO converter from a view point of weight and efficiency. Therefore, the thyristor converter is the best answer for AC inverter rolling stock, especially for commuter and interurban trains, in the next several years. For a thyristor converter, it is very important to prevent the commutative failure even when the category voltage decreases, in order to continue regenerating operation to sustain the brake torque. In a conventional system, a series resistance is inserted between the thyristor bridge and LC filter where the DC stage voltage is decreased enough to keep the regenerating power. The conventional thyristor enables regenerating braking in the whole operational region, but result in low power factor and efficiency. This paper proposes a new regenerating method to improve the power factor and efficiency, which keep regenerating power with no series resistance and higher DC stage voltage. Simulation results show the effectiveness of the method. 4 refs., 14 figs., 1 tab.

  8. High-voltage transistor converter for pulsed x-ray sources

    International Nuclear Information System (INIS)

    Krasil'nikov, S.B.; Kristalinskii, A.L.; Lozovoi, L.N.; Markov, S.N.; Sindalovskii, E.I.

    1986-01-01

    A 24-V/12-kV converter for MIRA-2D and NORA pulsed x-ray sources is described. When the low-voltage supply varies within 20-26 V, the frequency stability of the x-ray pulses is higher by a factor of 3 ≅ 3 than when the PRIMA converter is used. For 14-24 V, the average output power of the converter is independent of the load impedance and increases linearly with an increase in supply voltage. The efficiency of the converter reaches 60%. The converter operates in the temperature range of -40 to +60 0 C

  9. Comparison of converter topologies for charging capacitors used in pulsed load applications

    Science.gov (United States)

    Nelms, R. M.; Schatz, J. E.; Pollard, Barry

    1991-01-01

    The authors present a qualitative comparison of different power converter topologies which may be utilized for charging capacitors in pulsed power applications requiring voltages greater than 1 kV. The operation of the converters in capacitor charging applications is described, and relevant advantages are presented. All of the converters except one may be classified in the high-frequency switching category. One of the benefits from high-frequency operation is a reduction in size and weight. The other converter discussed is a member of the command resonant changing category. The authors first describe a boost circuit which functions as a command resonant charging circuit and utilizes a single pulse of current to charge the capacitor. The discussion of high-frequency converters begins with the flyback and Ward converters. Then, the series, parallel, and series/parallel resonant converters are examined.

  10. Full range ZVS DC-DC converter

    International Nuclear Information System (INIS)

    Upadhyay, Rinki; Badapanda, M.K.; Hannurkar, P.R.

    2011-01-01

    A 500 V, 24 Amp DC-DC converter with digital signal processor (DSP) based control and protection has been designed, fabricated and tested. Its power circuit consists of IGBT based single phase inverter bridge, ferrite transformer and diode rectifier. All IGBTs in the inverter bridge are operated in zero voltage switching (ZVS) mode to minimize switching losses thereby increasing the efficiency of the converter significantly. The efficiency of this converter is measured to be greater than 97% at full load. In a conventional full bridge inverter, typically ZVS is achieved under full load condition while at light load ZVS is lost. An auxiliary LC circuit has been intentionally incorporated in this converter to achieve ZVS even at light loaded conditions. Detailed simulation of the converter circuit is carried out and crucial waveforms have been presented in this paper. Microchip make dsPIC30F2020 DSP is employed to provide phase shifted PWMs to IGBTs in the inverter bridge. All the crucial parameters are also monitored by this DSP and in case of any unfavorable conditions, the converter is tripped off. Suitable experiments were carried out in this DC-DC converter under different loaded conditions and a close match between the simulated and experimental results were obtained. Such DC-DC converters can be connected in series or parallel for the development of solid state modular power supplies for various applications. (author)

  11. Half bridge resonant converter for ignition of thermal plasmas

    International Nuclear Information System (INIS)

    Pena E, L.

    1997-01-01

    In this work the background, design, implementation and performance of a half bridge resonant converter (HBRC) used as an electronic ignition system for arc plasma torch generation is presented. The significance of the design lies in its simplicity, versatility and low cost. The system operates like a high voltage supply attached to electrodes before gaseous breakdown and like open circuit when electric arc is established. Resonant converter is implemented with a high voltage and high speed power driver intended for control the power MOSFET transistors connected in half bridge topology with L C load. The HBRC operates besides interference into domestic electric supply line (120 V, 60 Hz) as well electric measurement devices. Advantages and limitations of the converter are reviewed. Experimental impedance variation in the medium as a function of frequency operation and some experiences in striking arcs are also presented. (Author)

  12. Study on a Novel High-Efficiency Bridgeless PFC Converter

    Directory of Open Access Journals (Sweden)

    Cao Taiqiang

    2014-01-01

    Full Text Available In order to implement a high-efficiency bridgeless power factor correction converter, a new topology and operation principles of continuous conduction mode (CCM and DC steady-state character of the converter are analyzed, which show that the converter not only has bipolar-gain characteristic but also has the same characteristic as the traditional Boost converter, while the voltage transfer ratio is not related with the resonant branch parameters and switching frequency. Based on the above topology, a novel bridgeless Bipolar-Gain Pseudo-Boost PFC converter is proposed. With this converter, the diode rectifier bridge of traditional AC-DC converter is eliminated, and zero-current switching of fast recovery diode is achieved. Thus, the efficiency is improved. Next, we also propose the one-cycle control policy of this converter. Finally, experiments are provided to verify the accuracy and feasibility of the proposed converter.

  13. Internal-Model-Principle-Based Specific Harmonics Repetitive Controller for Grid-Connected PWM Inverters

    Directory of Open Access Journals (Sweden)

    Wenzhou Lu

    2016-01-01

    Full Text Available This paper analyzes the general properties of IMP-based controller and presents an internal-model-principle-based (IMP-based specific harmonics repetitive control (SHRC scheme. The proposed SHRC is effective for specific nk±m order harmonics, with n>m≥0 and k=0,1,2,…. Using the properties of exponential function, SHRC can also be rewritten into the format of multiple resonant controllers in parallel, where the control gain of SHRC is n/2 multiple of that of conventional RC (CRC. Therefore, including SHRC in a stable closed-loop feedback control system, asymptotic disturbance eliminating, or reference tracking for any periodic signal only including these specific harmonic components at n/2 times faster error convergence rate compared with CRC can be achieved. Application examples of SHRC controlled three-phase/single-phase grid-connected PWM inverters demonstrate the effectiveness and advantages of the proposed SHRC scheme.

  14. A CMOS rail-to-rail linear VI-converter

    NARCIS (Netherlands)

    Vervoort, P.P.; Vervoort, P.P.; Wassenaar, R.F.

    1995-01-01

    A linear CMOS VI-converter operating in strong inversion with a common-mode input range from the negative to the positive supply rail is presented. The circuit consists of three linear VI-converters based on the difference of squares principle. Two of these perform the actual V to I conversion,

  15. A high voltage DC switching power supply of corona discharge for ozone tube

    International Nuclear Information System (INIS)

    Ketkaew, Siseerot

    2007-08-01

    Full text: This paper presents a study of design and construction of a high voltage DC switching power supply for corona generating of ozone gas generating. This supply uses fly back converter at 3 k Vdc 30 khz and controls its operation using PWM techniques. I C TL494 is controlled of the switching. The testing of supply by putting high voltage to ozone gas tube at one-hour, the oxygen quantity 21 % of air, which ozone tube model enables ozone gas generating capacity of 95.2 mgO3/hr

  16. Soft switching buck-boost converter for photovoltaic power generation; Taiyoko hatsuden no tame no soft switching shokoatsu converter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H. [Kyungnam University (Korea, Republic of)

    1996-10-27

    A soft switching method with small switching loss was proposed for the purpose of increasing the efficiency of a DC-DC boost converter which converted a DC current generated by solar cells to a variable DC current. Existing current converters are supplemented by using a snubber circuit around the switch so as to protect the switch by a hard switching action. However, with an increase of the output current, snubber loss is increased, reducing the efficiency. In order to solve this problem, the partial resonant switch method was applied to the converter; with this method of partially forming a resonant circuit only at the time of turning on/off of the switch, the switching loss was reduced through the soft switching, thereby making the proposed converter operate with high efficiency. Moreover, the resonant element of the partial resonant circuit using a snubber condenser, the energy accumulated in the condenser was regenerated on the power supply side without loss of snubber. With the regenerated energy, the proposed converter was provided with a smaller ratio of switching to use than the conventional converter. 4 refs., 7 figs., 1 tab.

  17. Hybrid-mode interleaved boost converter design for fuel cell electric vehicles

    International Nuclear Information System (INIS)

    Wen, Huiqing; Su, Bin

    2016-01-01

    Highlights: • A high power interleaved boost converter is designed for a 150 kW high-power fuel cell electric vehicle application. • A hybrid-mode scheme is used: Mode I and mode II are used with each boost converter operating in continuous conduction mode and discontinuous conduction mode. • Boundary conditions for different modes are determined with respect to switching duty ratio and load conditions. • With the proposed scheme, the power density is improved by 44.2% and 34.3% in terms of the converter volume and weight. - Abstract: For Fuel Cell Electric Vehicles, DC-DC power converters are essential to provide energy storage buffers between fuel cell stacks and the traction system because fuel cells show characteristics of low-voltage high-current output and wide output voltage variation. This paper presents a hybrid-mode two-phase interleaved boost converter for fuel cell electric vehicle application in order to improve the power density, minimize the input current ripple, and enhance the system efficiency. Two operation modes are adopted in the practical design: mode I and mode II are used with each boost converter operating in continuous conduction mode and discontinuous conduction mode. The operation, design and control of the interleaved boost converter for different operating modes are discussed with their equivalent circuits. The boundary conditions are distinguished with respect to switching duty ratio and load conditions. Transitions between continuous conduction mode and discontinuous conduction mode are illustrated for the whole duty ratio range. The expressions for inductor current ripple, input current ripple and output voltage ripple are derived and verified by simulation and experimental tests. The efficiency and power density improvements are illustrated to verify the effectiveness of the proposed design scheme.

  18. Fast simulation techniques for switching converters

    Science.gov (United States)

    King, Roger J.

    1987-01-01

    Techniques for simulating a switching converter are examined. The state equations for the equivalent circuits, which represent the switching converter, are presented and explained. The uses of the Newton-Raphson iteration, low ripple approximation, half-cycle symmetry, and discrete time equations to compute the interval durations are described. An example is presented in which these methods are illustrated by applying them to a parallel-loaded resonant inverter with three equivalent circuits for its continuous mode of operation.

  19. High-Efficiency Photovoltaic System Using Partially-Connected DC-DC Converter

    Science.gov (United States)

    Uno, Masatoshi; Kukita, Akio; Tanaka, Koji

    Power conversion electronics for photovoltaic (PV) systems are desired to operate as efficiently as possible to exploit the power generated by PV modules. This paper proposes a novel PV system in which a dc-dc converter is partially connected to series-connected PV modules. The proposed system achieves high power-conversion efficiency by reducing the passing power and input/output voltages of the converter. The theoretical operating principle was experimentally validated. Resultant efficiency performances of the proposed and conventional systems demonstrated that the proposed system was more efficient in terms of power conversion though the identical converter was used for the both systems.

  20. A Bidirectional Multi-Port DC-DC Converter Integrating Voltage Equalizer

    DEFF Research Database (Denmark)

    Chen, Jianfei; Hou, Shiying; Deng, Fujin

    2015-01-01

    A novel bidirectional multi-port dc-dc converter integrating voltage equalizer based on switched-capacitor voltage accumulator (SCVA) is proposed. It has two operating modes of charging and discharging for battery modules. All battery modules are connected in series indirectly and can be equalize...... battery modules with different voltages. Simulation results has shown the feasibility of the proposed converter.......A novel bidirectional multi-port dc-dc converter integrating voltage equalizer based on switched-capacitor voltage accumulator (SCVA) is proposed. It has two operating modes of charging and discharging for battery modules. All battery modules are connected in series indirectly and can be equalized...

  1. Current Mode Control for LLC Series Resonant DC-to-DC Converters

    OpenAIRE

    Jinhaeng Jang; Syam Kumar Pidaparthy; Byungcho Choi

    2015-01-01

    Conventional voltage mode control only offers limited performance for LLC series resonant DC-to-DC converters experiencing wide variations in operational conditions. When the existing voltage mode control is employed, the closed-loop performance of the converter is directly affected by unavoidable changes in power stage dynamics. Thus, a specific control design optimized at one particular operating point could become unacceptable when the operational condition is varied. This paper presents a...

  2. State trajectories used to observe and control dc-to-dc converters

    Science.gov (United States)

    Burns, W. W., III; Wilson, T. G.

    1976-01-01

    State-plane analysis techniques are employed to study the voltage stepup energy-storage dc-to-dc converter. Within this framework, an example converter operating under the influence of a constant on-time and a constant frequency controller is examined. Qualitative insight gained through this approach is used to develop a conceptual free-running control law for the voltage stepup converter which can achieve steady-state operation in one on/off cycle of control. Digital computer simulation data are presented to illustrate and verify the theoretical discussions presented.

  3. A novel power converter for photovoltaic applications

    Science.gov (United States)

    Yuvarajan, S.; Yu, Dachuan; Xu, Shanguang

    A simple and economical power conditioner to convert the power available from solar panels into 60 Hz ac voltage is described. The raw dc voltage from the solar panels is converted to a regulated dc voltage using a boost converter and a large capacitor and the dc output is then converted to 60 Hz ac using a bridge inverter. The ratio between the load current and the short-circuit current of a PV panel at maximum power point is nearly constant for different insolation (light) levels and this property is utilized in designing a simple maximum power point tracking (MPPT) controller. The controller includes a novel arrangement for sensing the short-circuit current without disturbing the operation of the PV panel and implementing MPPT. The switching losses in the inverter are reduced by using snubbers. The results obtained on an experimental converter are presented.

  4. A high-efficiency, low-noise power solution for a dual-channel GNSS RF receiver

    International Nuclear Information System (INIS)

    Shi Jian; Mo Taishan; Gan Yebing; Ma Chengyan; Ye Tianchun; Le Jianlian

    2012-01-01

    A high-efficiency low-noise power solution for a dual-channel GNSS RF receiver is presented. The power solution involves a DC—DC buck converter and a followed low-dropout regulator (LDO). The pulse-width-modulation (PWM) control method is adopted for better noise performance. An improved low-power high-frequency PWM control circuit is proposed, which halves the average quiescent current of the buck converter to 80 μA by periodically shutting down the OTA. The size of the output stage has also been optimized to achieve high efficiency under a light load condition. In addition, a novel soft-start circuit based on a current limiter has been implemented to avoid inrush current. Fabricated with commercial 180-nm CMOS technology, the DC—DC converter achieves a peak efficiency of 93.1% under a 2 MHz working frequency. The whole receiver consumes only 20.2 mA from a 3.3 V power supply and has a noise figure of 2.5 dB. (semiconductor integrated circuits)

  5. The New Modular Control System for Power Converters at CERN

    CERN Document Server

    Di Cosmo, Matteo

    2015-01-01

    The CERN accelerator complex consists of several generations of particle accelerators, with around 5000 power converters supplying regulated current and voltage to normal and superconducting magnet circuits. Today around 12 generations of converter control platforms can be found in the accelerator complex, ranging in age and technology. The diversity of these platforms has a significant impact on operability, maintenance and support of power converters. Over the past few years a new generation of modular controls called RegFGC3 has been developed by CERN’s power conversion group, with a goal to provide a standardised control platform, supporting a wide variety of converter topologies. The aim of this project is to reduce maintenance costs by decreasing the variety and diversity of control systems whilst simultaneously improving the operability and reliability of power converters and their controls. This paper describes the state of the on-going design and realization of the RegFGC3 platform, focusing on fun...

  6. Buck-Boost/Forward Hybrid Converter for PV Energy Conversion Applications

    Directory of Open Access Journals (Sweden)

    Sheng-Yu Tseng

    2014-01-01

    Full Text Available This paper presents a charger and LED lighting (discharger hybrid system with a PV array as its power source for electronic sign indicator applications. The charger adopts buck-boost converter which is operated in constant current mode to charge lead-acid battery and with the perturb and observe method to extract maximum power of PV arrays. Their control algorithms are implemented by microcontroller. Moreover, forward converter with active clamp circuit is operated in voltage regulation condition to drive LED for electronic sign applications. To simplify the circuit structure of the proposed hybrid converter, switches of two converters are integrated with the switch integration technique. With this approach, the proposed hybrid converter has several merits, which are less component counts, lighter weight, smaller size, and higher conversion efficiency. Finally, a prototype of LED driving system under output voltage of 10 V and output power of 20 W has been implemented to verify its feasibility. It is suitable for the electronic sign indicator applications.

  7. VHF Series-Input Parallel-Output Interleaved Self-Oscillating Resonant SEPIC Converter

    DEFF Research Database (Denmark)

    Kovacevic, Milovan; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    If the switches of two resonant SEPIC converters are capacitively coupled, it is possible to obtain a self-oscillating converter in which the two power stages operate in interleaved mode. This paper describes a topology where the inputs of two SEPIC converters are connected in series, thereby sha...

  8. Modeling the full-bridge series-resonant power converter

    Science.gov (United States)

    King, R. J.; Stuart, T. A.

    1982-01-01

    A steady state model is derived for the full-bridge series-resonant power converter. Normalized parametric curves for various currents and voltages are then plotted versus the triggering angle of the switching devices. The calculations are compared with experimental measurements made on a 50 kHz converter and a discussion of certain operating problems is presented.

  9. Design, status and first operations of the spallation neutron source polyphase resonant converter modulator system

    Energy Technology Data Exchange (ETDEWEB)

    Reass, W. A. (William A.); Apgar, S. E. (Sean E.); Baca, D. M. (David M.); Doss, James D.; Gonzales, J. (Jacqueline); Gribble, R. F. (Robert F.); Hardek, T. W. (Thomas W.); Lynch, M. T. (Michael T.); Rees, D. E. (Daniel E.); Tallerico, P. J. (Paul J.); Trujillo, P. B. (Pete B.); Anderson, D. E. (David E.); Heidenreich, D. A. (Dale A.); Hicks, J. D. (Jim D.); Leontiev, V. N.

    2003-01-01

    The Spallation Neutron Source (SNS) is a new 1.4 MW average power beam, 1 GeV accelerator being built at Oak Ridge National Laboratory. The accelerator requires 15 converter-modulator stations each providing between 9 and 11 MW pulses with up to a 1 .I MW average power. The converter-modulator can be described as a resonant 20 kHz polyphase boost inverter. Each converter modulator derives its buss voltage from a standard substation cast-core transformer. Each substation is followed by an SCR pre-regulator to accommodate voltage changes from no load to full load, in addition to providing a soft-start function. Energy storage is provided by self-clearing metallized hazy polypropylene traction capacitors. These capacitors do not fail short, but clear any internal anomaly. Three 'H-Bridge' IGBT transistor networks are used to generate the polyphase 20 kHz transformer primary drive waveforms. The 20 kHz drive waveforms are time-gated to generate the desired klystron pulse width. Pulse width modulation of the individual 20 lcHz pulses is utilized to provide regulated output waveforms with DSP based adaptive feedforward and feedback techniques. The boost transformer design utilizes nanocrystalline alloy that provides low core loss at design flux levels and switching frequencies. Capacitors are used on the transformer secondary networks to resonate the leakage inductance. The transformers are wound for a specific leakage inductance, not turns ratio. This design technique generates multiple secondary volts per turn as compared to the primary. With the appropriate tuning conditions, switching losses are minimized. The resonant topology has the added benefit of being deQed in a klystron fault condition, with little energy deposited in the arc. This obviates the need of crowbars or other related networks. A review of these design parameters, operational performance, production status, and OWL installation and performance to date will be presented.

  10. Design, status and first operations of the spallation neutron source polyphase resonant converter modulator system

    International Nuclear Information System (INIS)

    Reass, W.A.; Apgar, S.E.; Baca, D.M.; Doss, James D.; Gonzales, J.; Gribble, R.F.; Hardek, T.W.; Lynch, M.T.; Rees, D.E.; Tallerico, P.J.; Trujillo, P.B.; Anderson, D.E.; Heidenreich, D.A.; Hicks, J.D.; Leontiev, V.N.

    2003-01-01

    The Spallation Neutron Source (SNS) is a new 1.4 MW average power beam, 1 GeV accelerator being built at Oak Ridge National Laboratory. The accelerator requires 15 converter-modulator stations each providing between 9 and 11 MW pulses with up to a 1 .I MW average power. The converter-modulator can be described as a resonant 20 kHz polyphase boost inverter. Each converter modulator derives its buss voltage from a standard substation cast-core transformer. Each substation is followed by an SCR pre-regulator to accommodate voltage changes from no load to full load, in addition to providing a soft-start function. Energy storage is provided by self-clearing metallized hazy polypropylene traction capacitors. These capacitors do not fail short, but clear any internal anomaly. Three 'H-Bridge' IGBT transistor networks are used to generate the polyphase 20 kHz transformer primary drive waveforms. The 20 kHz drive waveforms are time-gated to generate the desired klystron pulse width. Pulse width modulation of the individual 20 lcHz pulses is utilized to provide regulated output waveforms with DSP based adaptive feedforward and feedback techniques. The boost transformer design utilizes nanocrystalline alloy that provides low core loss at design flux levels and switching frequencies. Capacitors are used on the transformer secondary networks to resonate the leakage inductance. The transformers are wound for a specific leakage inductance, not turns ratio. This design technique generates multiple secondary volts per turn as compared to the primary. With the appropriate tuning conditions, switching losses are minimized. The resonant topology has the added benefit of being deQed in a klystron fault condition, with little energy deposited in the arc. This obviates the need of crowbars or other related networks. A review of these design parameters, operational performance, production status, and OWL installation and performance to date will be presented.

  11. Digital control of grid connected converters for distributed power generation

    Energy Technology Data Exchange (ETDEWEB)

    Skjellnes, Tore

    2008-07-01

    Pulse width modulated converters are becoming increasingly popular as their cost decreases and power rating increases. The new trend of small scale power producers, often using renewable energy sources, has created new demands for delivery of energy to the grid. A major advantage of the pulse width modulated converter is the ability to control the output voltage at any point in the voltage period. This enables rapid response to load changes and non-linear loads. In addition it can shape the voltage in response to the output current to create an outward appearance of a source impedance. This is called a virtual impedance. This thesis presents a controller for a voltage controlled three phase pulse width modulated converter. This controller enables operation in standalone mode, in parallel with other converters in a micro grid, and in parallel with a strong main grid. A time varying virtual impedance is presented which mainly attenuates reactive currents. A method of investigating the overall impedance including the virtual impedance is presented. New net standards have been introduced, requiring the converter to operate even during severe dips in the grid voltage. Experiments are presented verifying the operation of the controller during voltage dips. (Author). 37 refs., 65 figs., 10 tabs

  12. Optimal trajectory control of a CLCC resonant power converter

    NARCIS (Netherlands)

    Huisman, H.; Visser, de I.; Duarte, J.L.

    2015-01-01

    A CLCC resonant converter to be used in an isolated power supply is operated using optimal trajectory control (OTC). As a consequence, the converter's inner loop behavior is changed to that of a controlled current source. The controller is implemented in an FPGA. Simulation results and recorded

  13. Development of Sliding Mode Controller for a Modified Boost Ćuk Converter Configuration

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2017-09-01

    Full Text Available This paper introduces a sliding mode control (SMC-based equivalent control method to a novel high output gain Ćuk converter. An additional inductor and capacitor improves the efficiency and output gain of the classical Ćuk converter. Classical proportional integral (PI controllers are widely used in direct current to direct current (DC-DC converters. However, it is a very challenging task to design a single PI controller operating in different loads and disturbances. An SMC-based equivalent control method which achieves a robust operation in a wide operation range is also proposed. Switching frequency is kept constant in appropriate intervals at different loading and disturbance conditions by implementing a dynamic hysteresis control method. Numerical simulations conducted in MATLAB/Simulink confirm the accuracy of analysis of high output gain modified Ćuk converter. In addition, the proposed equivalent control method is validated in different perturbations to demonstrate robust operation in wide operation range.

  14. Phase shift PWM with double two-switch bridge for high power capacitor charging

    International Nuclear Information System (INIS)

    Karandikar, U.S.; Singh, Yashpal; Thakurta, A.C.

    2013-01-01

    Pulse power supply systems working at higher voltage and high repetition rate demands for higher power from capacitor chargers. Capacitor charging requirement become more challenging in such cases. In pulse power circuits, energy storage capacitor should be charged to its desired voltage before the next switching occurs. It is discharged within a small time, delivering large pulse power. A capacitor charger has to work with wide load variation repeatedly. Many schemes are used for this purpose. The proposed scheme aims at reducing stresses on switches by reducing peak current and their evils. A high voltage power supply is designed for capacitor charging. The proposed scheme is based on a Phase-Shifted PWM without using any extra component to achieve soft switching. Indirect constant average current capacitor charging is achieved with a simple control scheme. A double two-switch bridge is proposed to enhance reliability. Power supply has been developed to charge a capacitor of 50 μF to 2.5 kV at 25 Hz. (author)

  15. Effects of cavitation on performance of automotive torque converter

    Directory of Open Access Journals (Sweden)

    Jaewon Ju

    2016-06-01

    Full Text Available Cavitation is a phenomenon whereby vapor bubbles of a flowing liquid are formed in a local region where the pressure of the liquid is below its vapor pressure. It is well known that cavitation in torque converters occurs frequently when a car with an automatic transmission makes an abrupt start. Cavitation is closely related to a performance drop and noise generation at a specific operating condition in a car and a torque converter itself. This study addressed the relation between cavitation and performance in an automotive torque converter in a quantitative and qualitative manner using numerical simulations. The cavitation was calculated at various operating conditions using a commercial flow solver with the homogeneous cavitation model, and the torque converter performance was compared with the experimental data. Numerical results well match to the data and indicate that the cavitation causes significant performance drop, as the pump speed increases or both speed ratio and reference pressure decrease.

  16. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    International Nuclear Information System (INIS)

    Zainal, Nurul Afiqah; Tat, Chan Sooi; Ajisman

    2016-01-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's output is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor. (paper)

  17. Distributed Generation Using Indirect Matrix Converter in Reverse Power Mode

    DEFF Research Database (Denmark)

    Liu, Xiong; Chiang Loh, Poh; Wang, Peng

    2013-01-01

    Indirect matrix converter (IMC) is an alternative for ac/ac energy conversion, usually operated with a voltage stepped-down gain of only 0.866. For applications like distribution generation where voltage-boost functionality is required, the traditional style of operating the IMC is therefore...... not appropriate. Like most power converters, the operation of the IMC can surely be reversed to produce a boosted gain, but so far its relevant control principles have not been discussed. These challenges are now addressed in this paper with distributed generation suggested as a potential application. Simulation...

  18. Combined analog-to-digital converter

    International Nuclear Information System (INIS)

    Zhukov, A.V.; Rzhendinskaya, S.N.

    1983-01-01

    A 10-bit analog-to-digital converter (ADC) designed for operating in spectrometers with time-dependent filters is described. The ADC operation is based on combining the parallel reading and sequential counting methods. At maximum conversion time of 12 μs, timing series frequency of 25 MHz and foUr reference levels the differential nonlinearity withoUt statistical smoothing (maximum relative channel width deviation from average value) is not more than 4%

  19. Conception and realization of a multichannel amplitude converter

    International Nuclear Information System (INIS)

    Bendebiche, L.

    1992-11-01

    A compact Analog to Digital Converter system suitable for high resolution γ-ray analysers has been developed based on the ADADC84 12-bit converter from Analog Devices. The converter was equipped with a peak detector and a stretcher, and with a memory card providing the sliding scale circuits, the lower threshold, the channel number identification and the zero suppression. The conversion time is 10 μs and the differential non linearity is less than ±1% for a 12-bit resolution. The converter consists of a 12-bit spectroscopy analog-to-digital converter (ADC) while the memory card includes a 8K 24-bit buffer memory. The two cards are plugged into a slot of an IBM PC AT and using an emulation software converts the micro-computer into a full-featured pulse height analyser. In data acquisition mode, the cards can operate independently, making the computer free for other tasks. The software offers acquisition control, visualization, data handling functions and various types of result presentation

  20. Optimizing design of converters using power cycling lifetime models

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup; Munk-Nielsen, Stig

    2015-01-01

    Converter power cycling lifetime depends heavily on converter operation point. A lifetime model of a single power module switched mode power supply with wide input voltage range is shown. A lifetime model is created using a power loss model, a thermal model and a model for power cycling capability...... with a given mission profile. A method to improve the expected lifetime of the converter is presented, taking into account switching frequency, input voltage and transformer turns ratio....

  1. Research & Implementation of AC - DC Converter with High Power Factor & High Efficiency

    Directory of Open Access Journals (Sweden)

    Hsiou-Hsian Nien

    2014-05-01

    Full Text Available In this paper, we design and develop a high power factor, high efficiency two-stage AC - DC power converter. This paper proposes a two-stage AC - DC power converter. The first stage is boost active power factor correction circuit. The latter stage is near constant frequency LLC resonant converter. In addition to traditional LLC high efficiency advantages, light-load conversion efficiency of this power converter can be improved. And it possesses high power factor and near constant frequency operating characteristics, can significantly reduce the electromagnetic interference. This paper first discusses the main structure and control manner of power factor correction circuit. And then by the LLC resonant converter equivalent model proceed to circuit analysis to determine the important parameters of the converter circuit elements. Then design a variable frequency resonant tank. The resonant frequency can change automatically on the basis of the load to reach near constant frequency operation and a purpose of high efficiency. Finally, actually design and produce an AC – DC power converter with output of 190W to verify the characteristics and feasibility of this converter. The experimental results show that in a very light load (9.5 W the efficiency is as high as 81%, the highest efficiency of 88% (90 W. Full load efficiency is 87%. At 19 W ~ 190 W power changes, the operating frequency change is only 0.4 kHz (AC 110 V and 0.3 kHz (AC 220 V.

  2. A NOVEL THREE PHASE UNITY POWER FACTOR CONVERTER

    Directory of Open Access Journals (Sweden)

    Bekir Sami SAZAK

    1998-03-01

    Full Text Available The proposed unity power factor converter system which is able to operate from a 150V three-phase supply whilst delivering the required 200V DC voltage has been built and tested. This circuit functions as a high power factor low harmonic rectifier based on the concept that the peak capacitor voltages are proportional to the line input currents. Hence the low frequency components of the capacitor voltages are also approximately proportional to the line input currents. The system can be designed to achieve nearly sinusoidal supply input currents, when operated with discontinuous resonant capacitor voltages Output power control is achieved by variations of the IGBTs switching frequency. The converter is therefore able to compensate for any changes in the load resistance. The proposed topology offers advantages, including: a relatively simple power, control and protection circuits, high power capability, and high converter efficiencies.

  3. Analysis of a high power, resonant DC-DC converter for DC wind turbines

    DEFF Research Database (Denmark)

    Dincan, Catalin Gabriel; Kjær, Philip Carne; Chen, Yu-Hsing

    2018-01-01

    This paper is introducing a new method of operation for a series resonant converter, with intended application in megawatt high-voltage DC wind turbines. Compared to a frequency controlled series resonant converter operated in sub resonant mode, the method (entitled pulse removal technique) allows...

  4. Energy-efficient three-phase bidirectional converter for grid-connected storage applications

    International Nuclear Information System (INIS)

    Colmenar-Santos, Antonio; Linares-Mena, Ana-Rosa; Velázquez, Jesús Fernández; Borge-Diez, David

    2016-01-01

    Highlights: • Storage control system developed based on AC DC three phase bidirectional converter. • Bidirectional AC DC converter for storage integration into distribution grids. • Efficiencies over 98% for values over 30% of the bidirectional converter rated power. • Sensitivity analysis of the parameters set by the transmission system operator. • Low-cost option for control and integration of new grid-connected storage systems. - Abstract: Grid connected energy storage systems are expected to play an essential role in the development of Smart Grids, providing, among other benefits, ancillary services to power grids. It is therefore crucial to design and develop control and conversion systems that represent the key instrument where intelligence for decision-making is applied, in order to validate and ensure its optimal operation as part and parcel of the electrical system. The present research describes the design and development of a battery energy storage system based on an AC-DC three-phase bidirectional converter capable of operating either in charge mode to store electrical energy, or in discharge mode to supply load demands. The design is modelled with MATLAB® Simulink® environment in order to evaluate the performance during load variations. Moreover, the assessment is complemented by a global sensitivity analysis for variations in the operating parameters set by the transmission system operator. The effectiveness of the simulation is confirmed by implementing the system and carrying out grid connection tests, obtaining efficiencies over 98% for values over the 30% of the bidirectional converter rated power.

  5. Converters for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng

    2015-01-01

    Power electronics technology has become the enabling technology for the integration of distributed power generation systems (DPGS) such as offshore wind turbine power systems and commercial photovoltaic power plants. Depending on the applications, a vast array of DPGS-based power converter...... topologies has been developed and more are coming into the market in order to achieve an efficient and reliable power conversion from the renewables. In addition, stringent demands from both the distribution system operators and the consumers have been imposed on the renewable-based DPGS. This article...... presents an overview of the power converters for the DPGS, mainly based on wind turbine systems and photovoltaic systems, covering a wide range of applications. Moreover, the modulation schemes and interfacing power filters for the power converters are also exemplified. Finally, the general control...

  6. A Novel Quasi-SEPIC High-Voltage Boost DC-DC Converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; N. Soltani, Mohsen; Blaabjerg, Frede

    2017-01-01

    This paper proposes a modified coupled-inductor SEPIC dc-dc converter for low power and high voltage gain applications such as for piezoelectric drive systems. The converter uses the same components as of SEPIC converter with an additional diode. Compared to conventional topologies with similar...... voltage gain expression, the proposed topology uses less components to achieve same or even higher voltage gain. This helps to design a very compact and light weight converter with higher power density at lower cost. Due to brevity, the principle of operation, theoretical analysis and comparison supported...

  7. Angle Stability Analysis for Voltage-Controlled Converters

    DEFF Research Database (Denmark)

    Lin, Hengwei; Jia, Chenxi; Guerrero, Josep M.

    2017-01-01

    a criterion to analyze the quasi-steady angle stability and the direct current (DC) side stability for VSCs. The operating limit and the angle instability mechanism are revealed, which is generally applicable to the voltage-controlled converters. During the analysis, the influence of the parameters on angle...... stability is studied. Further, the difference on instability mechanism between power electronic converters and synchronous generators are explained in detail. Finally, experiment results with corrective actions verify the analysis....

  8. Analysis and Design of Embedded Controlled Parallel Resonant Converter

    Directory of Open Access Journals (Sweden)

    P. CHANDRASEKHAR

    2009-07-01

    Full Text Available Microcontroller based constant frequency controlled full bridge LC parallel resonant converter is presented in this paper for electrolyser application. An electrolyser is a part of renewable energy system which generates hydrogen from water electrolysis. The DC power required by the electrolyser system is supplied by the DC-DC converter. Owing to operation under constant frequency, the filter designs are simplified and utilization of magnetic components is improved. This converter has advantages like high power density, low EMI and reduced switching stresses. DC-DC converter system is simulated using MATLAB, Simulink. Detailed simulation results are presented. The simulation results are compared with the experimental results.

  9. Determination of input/output characteristics of full-bridge AC/DC/DC converter for arc welding

    OpenAIRE

    Stefanov, Goce; Karadzinov, Ljupco; Sarac, Vasilija; Cingoski, Vlatko; Gelev, Saso

    2016-01-01

    This paper describes the design and practical implementation of AC/DC/DC converter in mode of arc welding. An analysis of the operation of AC/DC/DC converter and its input/output characteristics are determined with computer simulations. The practical part is consisted of AC/DC/DC converter prototype for arc welding with output power of 3 kW and switching frequency of 64 kHz. The operation of AC/DC/DC converter is validated with experimental measurements.

  10. The Topologies Research of a Soft Switching Bidirectional DC/DC Converter

    DEFF Research Database (Denmark)

    Zhang, Qi; Zhang, Yongping; Sun, Xiangdong

    2017-01-01

    A soft-switching solution implemented to the traditional bidirectional DC/DC converter is developed. The soft-switching cell, which composed of three auxiliary switches, one resonant capacitor and one resonant inductor, is equipped in the traditional bidirectional DC/DC converter to realize circuit...... circle. And the proposed topology of bidirectional soft-switching dc-dc converter(TASBC) performs ideal soft switching at boost operations. The characteristics of the proposed converter has been verified by MATLAB simulations and experimental results....

  11. Lithium converter of reactor neutrinos in antineutrino

    International Nuclear Information System (INIS)

    Lyutostanskij, Yu.S.; Lyashuk, V.I.

    1989-01-01

    The questions of developing lithium converter of the reactor neutrons in antineutrino operating at dynamic regime in the scheme with the cycle circulation of the high-purified lithium (by 7 Li isotope) through the converter are considered. The scheme allows to localize the 8 Li β-decay (T 1/2 =0.84 s) in the reservoir near the detector and so to design the hard-spectrum lithium ν-tilde e -source (E max ≅13 MeV) at the distance from the active zone being the soft-spectrum ν-tilde e -source. The expressions for the lithium ν-tilde e flux from the converter, reservoir and conveyance channel are obtained. 9 refs.; 8 figs.; 1 tab

  12. Vibration and acoustic noise emitted by dry-type air-core reactors under PWM voltage excitation

    Science.gov (United States)

    Li, Jingsong; Wang, Shanming; Hong, Jianfeng; Yang, Zhanlu; Jiang, Shengqian; Xia, Shichong

    2018-05-01

    According to coupling way between the magnetic field and the structural order, structure mode is discussed by engaging finite element (FE) method and both natural frequency and modal shape for a dry-type air-core reactor (DAR) are obtained in this paper. On the basis of harmonic response analysis, electromagnetic force under PWM (Pulse Width Modulation) voltage excitation is mapped with the structure mesh, the vibration spectrum is gained and the consequences represents that the whole structure vibration predominates in the radial direction, with less axial vibration. Referring to the test standard of reactor noise, the rules of emitted noise of the DAR are measured and analyzed at chosen switching frequency matches the sample resonant frequency and the methods of active vibration and noise reduction are put forward. Finally, the low acoustic noise emission of a prototype DAR is verified by measurement.

  13. Criteria for extending the operation periods of thermoelectric converters based on IV-VI compounds

    Energy Technology Data Exchange (ETDEWEB)

    Sadia, Yatir, E-mail: yatttir@yahoo.com [Department of Materials Engineering, Ben-Gurion University of the Negev, Beer-Sheva (Israel); Ohaion-Raz, Tsion [Department of Chemistry, Ben-Gurion University of the Negev, Beer-Sheva (Israel); Ben-Yehuda, Ohad; Korngold, Meidad; Gelbstein, Yaniv [Department of Materials Engineering, Ben-Gurion University of the Negev, Beer-Sheva (Israel)

    2016-09-15

    The recent energy demands affected by the dilution of conventional energy resources and the growing awareness of environmental considerations, had positioned the research of renewable energy conversion methods in general and of thermoelectric direct conversion of thermal into electrical energies in particular, in the forefront of the currently active applicative sciences. IV-VI thermoelectric compounds (e.g. GeTe, PbTe and SnTe) and their alloys comprise some of the most efficient thermoelectric compositions ever reported. Yet a proper utilization of such materials in practical thermoelectric devices, still requires an overcoming the so-called technological “valley of death”, including among others, transport properties' degradation, due to sublimation of volatile Te rich species, while being subjected to elevated temperatures for long periods of time. In an attempt to establish practical operation criteria for extending the operation periods of such thermoelectric converters, it is currently shown based on thermal gravimetric and metallurgical considerations that such harmful sublimation can be practically bridged over by limiting the maximal operating temperatures to the 410–430 °C range for GeTe rich alloys and to 510–530 °C for PbTe and SnTe rich alloys, depending of the thermoelectric leg's diameter. - Graphical abstract: Evaporation rate in the GeTe and PbTe system showing the measured evaporation rates and the maximal operating temperatures for different compositions. In addition, the microstructure after evaporation is shown for PbTe, TAGS-85, and doped Pb{sub 0.13}Ge{sub 087}Te. Display Omitted - Highlights: • Evaporation rates of GeTe and PbTe based thermoelectric compounds were determined. • A criterion for their maximum operating temperature was established. • The materials showed phase separations and off-stoichiometry compositions.

  14. Integrated hybrid switched-capacitor converter for LED drivers in 180 nm CMOS

    NARCIS (Netherlands)

    Castellanos Rodriguez, J.; Delos, J.; Hendrix, M.A.M.; Van Roermund, A.; Cantatore, E.

    2016-01-01

    This paper presents a LED driver based on a new Hybrid-Switched Capacitor Converter (H-SCC) operating in the MHz range, which uses the internal pulsed nodes of a Dickson converter and an LC output network to provide output current dimming. The converter is implemented using 5V integrated capacitors

  15. An isolated bridgeless AC-DC PFC converter using a LC resonant voltage doubler rectifier

    Science.gov (United States)

    Lee, Sin-woo; Do, Hyun-Lark

    2016-12-01

    This paper proposed an isolated bridgeless AC-DC power factor correction (PFC) converter using a LC resonant voltage doubler rectifier. The proposed converter is based on isolated conventional single-ended primary inductance converter (SEPIC) PFC converter. The conduction loss of rectification is reduced than a conventional one because the proposed converter is designed to eliminate a full-bridge rectifier at an input stage. Moreover, for zero-current switching (ZCS) operation and low voltage stresses of output diodes, the secondary of the proposed converter is designed as voltage doubler with a LC resonant tank. Additionally, an input-output electrical isolation is provided for safety standard. In conclusion, high power factor is achieved and efficiency is improved. The operational principles, steady-state analysis and design equations of the proposed converter are described in detail. Experimental results from a 60 W prototype at a constant switching frequency 100 kHz are presented to verify the performance of the proposed converter.

  16. A comparative investigation of three PM-less MW power range wind generator topologies

    DEFF Research Database (Denmark)

    Bratiloveanu, Catalin-Rauti; Traian Cosmin Anghelus, Dumitru; Boldea, I.

    2012-01-01

    As the wind energy penetration range increases steadily and the high energy PM costs are rising dramatically, PM-less large power wind generators with high performance are needed. Apart from extending the range of cage rotor induction generators, doubly-fed induction generators and dc excited...... investigates by quasi 2D-FEM two dc stator polarized (to increase machine side PWM converter voltage utilization, that is to reduce peak kVA ratings and costs of the machine side PWM converter) directly-driven switched reluctance generators (one with circumferential field and one with transverse flux (with...... heteropolar-rotor (standard) synchronous generators, especially for direct drives (very low speed) and multibrid (with single stage transmission (5/1-8/1 ratio)), new topologies have to be investigated to reduce initial costs and weights for high enough efficiency and energy annual yield. The present paper...

  17. Evolution of the SPS Power Converter Controls towards the LHC Era

    CERN Document Server

    Brazier, J.C.L.; Semanaz, P.

    2001-01-01

    By the end of the nineties, the power converter control system (Mugef) of the CERN proton accelerator (SPS) had undergone a complete modernization. This resulted in newly developed hardware for function generation, measurement and I/O in a VME environment, under the LynxOS real-time operating system. This has provided a platform on which extensions can be developed for future operation in the Large Hadron Collider (LHC) era. This paper describes some of these extensions, in particular a fast Surveillance and Interlock system for monitoring the power converter output currents. This will be mandatory for the safe operation of the SPS transfer lines TI2 & TI8 to LHC and for similar applications in the future. The strategies employed to cope with various failure modes of the power converters and the timely activation of the interlock are outlined. The new SPS controls infrastructure now under development, will give rise to new modes of operation for the Mugef systems. Integration with the proposed middleware ...

  18. A comparative design view for accurate control of servos using a field programmable gate array

    International Nuclear Information System (INIS)

    Tickle, A J; Harvey, P K; Smith, J S; Wu, F; Buckle, J R

    2009-01-01

    An embedded system is a special-purpose computer system designed to perform one or a few dedicated functions. Altera DSP Builder presents designers and users with an alternate approach when creating their systems by employing a blockset similar to that already used in Simulink. The application considered in this paper is the design of a Pulse Width Modulation (PWM) system for use in stereo vision. PWM can replace a digital-to-analogue converter to control audio speakers, LED intensity, motor speed, and servo position. Rather than the conventional HDL coding approach this Simulink approach provides an easy understanding platform to the PWM design. This paper includes a comparison between two approaches regarding resource usage and flexibility etc. Included is how DSP Builder manipulates an onboard clock signal, in order to create the control pulses to the 'raw' coding of a PWM generator in VHDL. Both methods were shown to a selection of people and their views on which version they would subsequently use in their relative fields is discussed.

  19. submitter Test strategies for industrial testers for converter controls equipment

    CERN Document Server

    Oleniuk, P; Kasampalis, V; Nisbet, D; Todd, B; Uznański, S

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary s...

  20. Analysis of an AC-DC full-controlled converter supplying two DC-Series-Motor loads

    International Nuclear Information System (INIS)

    Al-Hindawi, Mohammed M.; Al-Turki, Yusuf A.; Al-Subaie, Obaid T.

    2000-01-01

    Phase-controlled converters are widely used because these converters are simple, less expensive, reliable, and do not require any communication circuit. Series motors are extensively used in many applications that require both high starting torque and essentially constant horse power. This paper is concerned with the detailed study of the performance characteristics of an AC-DC full-controlled converter supplying two DC-series-motor loads. The converter loads combination is simulated on a digital computer. Different modes of operation (continuous and discontinuous converter currents) are considered. The critical firing angle at which the mode of operation changes from one mode to another is deduced. The performance characteristics such input power factor, supply current distortion factor, supply current fundamental power factor, torque speed, and motor current ripple factor have been derived and studied for both constant firing angle and constant load factor have been derived and studied for both constant firing angle and constant load power of one motor. Waveforms for each load current and converter current are investigated for different modes of operation. (author)

  1. Mechatronics control technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-03-15

    This book consists six chapters, which are an assembler grammar and practical use on Z801 8041/8048 and kind of assemblers and how to use, control of a microprocessor and mechatro with application of 8255, interface circuit and direction of DA converter, control of stepping motor such as introduction of it, sequence switch, drive program of stepping motor, control for DC motor such as normal rotation and abnormal rotation operation of DC motor by personal computer, control AC motor like PWM inverter and data communication among systems such as RS-232C and INTEL-HEXA format program.

  2. Mechatronics control technology

    International Nuclear Information System (INIS)

    1988-03-01

    This book consists six chapters, which are an assembler grammar and practical use on Z801 8041/8048 and kind of assemblers and how to use, control of a microprocessor and mechatro with application of 8255, interface circuit and direction of DA converter, control of stepping motor such as introduction of it, sequence switch, drive program of stepping motor, control for DC motor such as normal rotation and abnormal rotation operation of DC motor by personal computer, control AC motor like PWM inverter and data communication among systems such as RS-232C and INTEL-HEXA format program.

  3. A Zero Input Current Ripple ZVS/ZCS Boost Converter with Boundary-Mode Control

    Directory of Open Access Journals (Sweden)

    Ching-Ming Lai

    2014-10-01

    Full Text Available In this paper, in order to achieve zero ripple conditions, the use of a ripple mirror (RM circuit for the boost converter is proposed. The operation modes are studied and steady-state analyses performed to show the merits of the proposed converter. It is found that the proposed RM circuit technique can provide much better flexibility than the two-phase interleaved boost converter for locating the zero ripple operating point in the design stage. In addition, the choice of using a boundary-mode control is mainly based on the consideration of achieving both ZVS (zero voltage switching/ZCS (zero current switching soft-switching and constant on-time control for the converter. To verify the performance of the proposed converter, a 48 V input and 200 W/200 V output prototype is constructed. Experimental results verify the effectiveness of the proposed converter.

  4. A multioutput LLC-type parallel resonant converter

    Science.gov (United States)

    Liu, Rui; Lee, C. Q.; Upadhyay, Anand K.

    1992-07-01

    When an LLC-type parallel resonant converter (LLC-PRC) operates above resonant frequency, the switching transistors can be turned off at zero voltage. Further study reveals that the LLC-PRC possesses the advantage of lower converter voltage gain as compared with the conventional PRC. Based on analytic results, a complete set of design curves is obtained, from which a systematic design procedure is developed. Experimental results from a 150 W 150 kHz multioutput LLC-type PRC power supply are presented.

  5. CMOS sigma-delta converters practical design guide

    CERN Document Server

    De la Rosa, Jose M

    2013-01-01

    A comprehensive overview of Sigma-Delta Analog-to-Digital Converters (ADCs) and a practical guide to their design in nano-scale CMOS for optimal performance. This book presents a systematic and comprehensive compilation of sigma-delta converter operating principles, the new advances in architectures and circuits, design methodologies and practical considerations - going from system-level specifications to silicon integration, packaging and measurements, with emphasis on nanometer CMOS implementation. The book emphasizes practical design issues - from high-level behavioural modelling i

  6. A Multi-Functional Power Electronic Converter in Distributed Generation Power Systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Pedersen, John Kim

    2005-01-01

    of the converter interfacing a wind power generation unit is also given. The power electronic interface performs the optimal operation in the wind turbine system to extract the maximum wind power, while it also plays a key role in a hybrid compensation system that consists of the active power electronic converter......This paper presents a power electronic converter which is used as an interface for a distributed generation unit/energy storage device, and also functioned as an active power compensator in a hybrid compensation system. The operation and control of the converter have been described. An example...... and passive filters connected to each distorting load or distributed generation (DG) unit. The passive filters are distributely located to remove major harmonics and provide reactive power compensation. The active power electronic filter corrects the system unbalance, removes the remaining harmonic components...

  7. Self-oscillating loop based piezoelectric power converter

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a piezoelectric power converter comprising an input driver electrically coupled directly to an input or primary electrode of the piezoelectric transformer without any intervening series or parallel inductor. A feedback loop is operatively coupled between an output......- oscillation loop within a zero-voltage-switching (ZVS) operation range of the piezoelectric transformer....

  8. Thermal analysis of multi-MW two-level wind power converter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Mogens, Lau

    2012-01-01

    In this paper, the multi-MW wind turbine of partial-scale and full-scale two-level power converter with DFIG and direct-drive PMSG are designed and compared in terms of their thermal performance. Simulations of different configurations regarding loss distribution and junction temperature...... in the power device in the whole range of wind speed are presented and analyzed. It is concluded that in both partial-scale and full-scale power converter the most thermal stressed power device in the generator-side converter will have higher mean junction temperature and larger junction temperature...... fluctuation compared to grid-side converter at the rated wind speed. Moreover, the thermal performance of the generator-side converter in the partial-scale power converter becomes crucial around the synchronous operating point and should be considered carefully....

  9. High-frequency high-voltage high-power DC-to-DC converters

    Science.gov (United States)

    Wilson, T. G.; Owen, H. A.; Wilson, P. M.

    1982-09-01

    A simple analysis of the current and voltage waveshapes associated with the power transistor and the power diode in an example current-or-voltage step-up (buck-boost) converter is presented. The purpose of the analysis is to provide an overview of the problems and design trade-offs which must be addressed as high-power high-voltage converters are operated at switching frequencies in the range of 100 kHz and beyond. Although the analysis focuses on the current-or-voltage step-up converter as the vehicle for discussion, the basic principles presented are applicable to other converter topologies as well.

  10. Benefits and Drawbacks of A High Frequency Gan Zvzcps Converter

    Directory of Open Access Journals (Sweden)

    Blanes J. M.

    2017-01-01

    Full Text Available This paper presents the benefits and drawbacks of replacing the traditional Si Mosfets transistors with enhancement mode GaN transistors in a Half-Bridge Zero Voltage and Zero Current Switching Power Switching (ZVZCPS converter. This type of converters is usually used as Electronic Power Converters (EPC for telecommunication satellites travelling-wave tube amplifiers (TWTAs. In this study, firstly the converter is theoretically analysed, obtaining its operation, losses and efficiency equations. From these equations, optimizations maps based on the main system parameters are obtained. These optimization maps are the key to quantify the potential benefits of GaN transistors in this type of converters. Theoretical results show that using GaN transistors, the frequency of the converter can be pushed from 125kHz to 830kHz without sacrificing the converter efficiency. This frequency increase is directly related to reduction on the EPC size and weight.

  11. A CMOS/SOI Single-input PWM Discriminator for Low-voltage Body-implanted Applications

    Directory of Open Access Journals (Sweden)

    Jader A. De Lima

    2002-01-01

    Full Text Available A CMOS/SOI circuit to decode Pulse-Width Modulation (PWM signals is presented as part of a body-implanted neurostimulator for visual prosthesis. Since encoded data is the sole input to the circuit, the decoding technique is based on a novel double-integration concept and does not require low-pass filtering. Non-overlapping control phases are internally derived from the incoming pulses and a fast-settling comparator ensures good discrimination accuracy in the megahertz range. The circuit was integrated on a 2 μm single-metal thin-film CMOS/SOI fabrication process and has an effective area of 2 mm2. Measured resolution of encoding parameter α is better than 10% at 6 MHz and VDD = 3.3 V. Idle-mode consumption is 340 μW. Pulses of frequencies up to15 MHz and α =10% can be discriminated for 2.3 V ≤ VDD ≤ 3.3 V. Such an excellent immunity to VDD deviations meets a design specification with respect to inherent coupling losses on transmitting data and power by means of a transcutaneous link.

  12. A Cost-Effective Design and Analysis of Full Bridge LLC Resonant Converter

    OpenAIRE

    Kaibalya Prasad Panda; Sreyasee Rout

    2016-01-01

    LLC (Inductor-inductor-capacitor) resonant converter has lots of advantages over other type of resonant converters which include high efficiency, more reliable and have high power density. This paper presents the design and analysis of a full bridge LLC resonant converter. In addition to the operational principle, the ZVS and ZCS conditions are also explained with the DC characteristics. Simulation of the LLC resonant converter is performed in MATLAB/ Simulink and the practical prototype setu...

  13. Multi-port isolated LLC resonant converter for distributed energy generation with energy storage

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Zhang, Zhe; Ouyang, Ziwei

    2017-01-01

    regulation increase in complexity. In this paper, an isolated multi-port bidirectional converter based on an LLC converter is presented. The converter operates as a dc transformer at a fixed switching frequency and duty cycle without any control loop. The resonant tanks are designed to ensure soft...

  14. Impact analysis of tap switch out of step for converter transformer

    Science.gov (United States)

    Hong-yue, ZHANG; Zhen-hua, ZHANG; Zhang-xue, XIONG; Gao-wang, YU

    2017-06-01

    AC transformer load regulation is mainly used to adjust the load side voltage level, improve the quality of power supply, the voltage range is relatively narrow. In DC system, converter transformer is the core equipment of AC and DC power converter and inverter. converter transformer tap adjustment can maintain the normal operation of the converter in small angle range control, the absorption of reactive power, economic operation, valve less stress, valve damping circuit loss, AC / DC harmonic component is also smaller. In this way, the tap switch action is more frequent, and a large range of the tap switch adjustment is required. Converter transformer with a more load voltage regulation switch, the voltage regulation range of the switch is generally 20~30%, the adjustment of each file is 1%~2%. Recently it is often found that the tap switch of Converter Transformers is out of step in Converter station. In this paper, it is analyzed in detail the impact of tap switch out of step for differential protection, overexcitation protection and zero sequence over current protection. Analysis results show that: the tap switch out of step has no effect on the differential protection and the overexcitation protection including the tap switch. But the tap switch out of step has effect on zero sequence overcurrent protection of out of step star-angle converter transformer. The zero sequence overcurrent protection will trip when the tap switch out of step is greater than 3 for out of step star-angle converter transformer.

  15. Two-Phase Induction Motor Drives

    Directory of Open Access Journals (Sweden)

    Gholam Reza Arab Markadeh

    2010-10-01

    Full Text Available The lack of variable-speed drives for two (single induction motor is a reality. This article attempts mainly to investigate the reasons for this lack of variable – speed drives. This paper deals with literature survey of various existing converter topologies, which have been proposed for adjustable speed single phase induction motor drives. Various converter topologies have been compared in this paper. Among these converter topologies, the adjustable frequency PWM inverter is the best choice for single-phase induction motor drives. However, adjustable-frequency drives have not been widely used with single-phase Induction motors. The open-loop constant V/F control law cannot be used with the single-phase induction motor drives as it is used with three phase motors. The variation of the operating frequency at lower speed range with constant load torque causes variation in motor's slip. A constant V/F control is suitable only over the upper speed range.

  16. Electric converters of electromagnetic strike machine with battery power

    Science.gov (United States)

    Usanov, K. M.; Volgin, A. V.; Kargin, V. A.; Moiseev, A. P.; Chetverikov, E. A.

    2018-03-01

    At present, the application of pulse linear electromagnetic engines to drive strike machines for immersion of rod elements into the soil, strike drilling of shallow wells, dynamic probing of soils is recognized as quite effective. The pulse linear electromagnetic engine performs discrete consumption and conversion of electrical energy into mechanical work. Pulse dosing of a stream transmitted by the battery source to the pulse linear electromagnetic engine of the energy is provided by the electrical converter. The electric converters with the control of an electromagnetic strike machine as functions of time and armature movement, which form the unipolar supply pulses of voltage and current necessary for the normal operation of a pulse linear electromagnetic engine, are proposed. Electric converters are stable in operation, implement the necessary range of output parameters control determined by the technological process conditions, have noise immunity and automatic disconnection of power supply in emergency modes.

  17. DC electric springs with DC/DC converters

    DEFF Research Database (Denmark)

    Wang, Qingsong; Cheng, Ming; Jiang, Yunlei

    2016-01-01

    The concept of DC electric spring (DCES) was recently proposed to solve the stability issue caused by integrating intermittent renewable energy sources (RESs) to DC microgrids. In this paper, a new topology of DCES is proposed based on DC/DC converters. The proposed DCES consists of a bi-directio......The concept of DC electric spring (DCES) was recently proposed to solve the stability issue caused by integrating intermittent renewable energy sources (RESs) to DC microgrids. In this paper, a new topology of DCES is proposed based on DC/DC converters. The proposed DCES consists of a bi...... and/or constant discharging for batteries is adopted and four operating modes are analyzed as charging-positive, charging-negative, discharging-positive and discharging-negative modes. An additional mechanism for fast charging or fast discharging is also designed to secure normal operation...... of batteries. With the proposed DCES, the power fluctuations due to intermittent RESs can be passed to non-critical loads (NCLs) and batteries while power on critical loads (CLs) is kept stable. This is possibly the first attempt to design a DCES with only DC/DC converters. The performances of the proposed...

  18. Experimental study of a reverse flow catalytic converter for a duel fuel engine

    Energy Technology Data Exchange (ETDEWEB)

    Liu, B.; Checkel, M. D. [Alberta Univ., Dept. of Mechanical Engineering, Edmonton, ANB (Canada); Hayes, R. E. [Alberta Univ., Dept, of Chemical and Materials Engineering, Edmonton, AB, (Canada)

    2001-08-01

    Performance of a reverse flow catalytic converter for a methane/diesel dual fuel engine is evaluated under steady and transient engine conditions. The converter is of the monolith honeycomb type with palladium catalyst washcoat. Results of the reverse flow converter's performance was found to be superior for several steady state engine operations when compared to unidirectional flow operation. In transient operations following a step change in engine operating conditions, reverse flow was found to be better than unidirectional flow when the change in engine operation was such as to reduce the exhaust gas temperature. When exhaust gas temperature was increased, reverse flow decreased the rate of increase in the reactor temperature. Testing was done using the transient Japanese 6-Mode tests. Best results were achieved with a switch time in the five seconds to fifteen seconds range. 31 refs., 9 tabs., 24 figs.

  19. Simulation analysis of cascade controller for DC-DC bank converter

    International Nuclear Information System (INIS)

    Mahar, M.A.; Abro, M.R.; Larik, A.S.

    2009-01-01

    Power electronic converters are periodic variable structure systems due to their switched operation. During the last few decades several new dc-dc converter topologies have emerged. Buck converter being simple in topology, has recently drawn attraction of many researchers. Basically, a buck converter is highly underdamped system. In order to overcome the developed oscillations in output of this converter, various control techniques have been proposed. However, these techniques are fraught with many drawbacks. This paper focus on a cascade controller based buck topology. Steady state analysis is given in this paper which shows output voltage and inductor current in detail. Dynamic analysis for line and load variation is also presented. The buck topology is implemented and simulated in MATLAB/Simulink. The simulated results are presented. (author)

  20. DC-DC power converter research for Orbiter/Station power exchange

    Science.gov (United States)

    Ehsani, M.

    1993-01-01

    This project was to produce innovative DC-DC power converter concepts which are appropriate for the power exchange between the Orbiter and the Space Station Freedom (SSF). The new converters must interface three regulated power buses on SSF, which are at different voltages, with three fuel cell power buses on the Orbiter which can be at different voltages and should be tracked independently. Power exchange is to be bi-directional between the SSF and the Orbiter. The new converters must satisfy the above operational requirements with better weight, volume, efficiency, and reliability than is available from the present conventional technology. Two families of zero current DC-DC converters were developed and successfully adapted to this application. Most of the converters developed are new and are presented.

  1. Battery charger with a capacitor-diode clamped LLC resonant converter

    OpenAIRE

    Tsang, C.; Bingham, C.; Foster, M. P.; Stone, D.; Leech, J.

    2016-01-01

    The paper proposes a novel battery charger through use of\\ud two serially-connected LLC resonant converters. The first\\ud stage utilises a capacitor-diode clamped LLC resonant\\ud converter which allows operation in both constant voltage\\ud (CV) and constant current (CC) modes, as found in most\\ud battery chargers, to be realised, whilst the second stage\\ud provides the necessary gain and line and load regulation. A\\ud design example is included that demonstrates the resulting\\ud converter top...

  2. A frequency controlled LCL - T resonant converter for H- ion source

    International Nuclear Information System (INIS)

    Gauttam, V.K.; Kasliwal, A.; Banwari, R.; Pandit, T.G.; Thakurta, A.C.

    2013-01-01

    An H - ion source is being developed at Raja Ramanna Centre for Advanced Technology, Indore. An LCL-T resonant power converter with variable frequency control is proposed which is utilized to develop a -20 kV/100 mA high voltage (HV) power supply for extraction of H - ions. The LCL-T resonant topology offers many advantages like gainful utilization of the transformer parasitics as a part of resonant network and low circulating current. The power converter is operated with variable frequency control and above resonance to get well known zero-voltage switching (ZVS) advantages for full bridge semiconductor switches in full load range. The converter energizes the symmetrical Cockcroft-Walton (CW) based HV generator to achieve required high voltage. The CW circuit is an attractive solution for HV generation since it has features like low stored energy and low output ripple. The HV power supply is operated in constant current (CC) mode with closed loop control and soft start of the power supply is achieved by sweeping the switching frequency from 40 kHz to defined operating point. Design parameters, simulation results and experimental results of the power converter are presented in this paper. (author)

  3. Direct-current vector control of three-phase grid-connected rectifier-inverter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuhui; Haskew, Timothy A.; Hong, Yang-Ki; Xu, Ling [Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35475 (United States)

    2011-02-15

    The three-phase grid-connected converter is widely used in renewable and electric power system applications. Traditionally, control of the three-phase grid-connected converter is based on the standard decoupled d-q vector control mechanism. Nevertheless, the study of this paper shows that there is a limitation in the conventional standard vector control method. Some of the limitations have also been found recently by other researchers. To overcome the shortage of the conventional vector control technique, this paper proposes a new direct-current d-q vector control mechanism in a nested-loop control structure, based on which an optimal control strategy is developed in a nonlinear programming formulation. The behaviors of both the conventional and proposed control methods are compared and evaluated in simulation and laboratory hardware experiment environments, both of which demonstrates that the proposed approach is effective for grid-connected power converter control in a wide system conditions while the conventional standard vector control approach may behave improperly especially when the converter operates beyond its PWM saturation limit. (author)

  4. Fixed speed wind farm operation improvement using current-source converter based UPQC

    International Nuclear Information System (INIS)

    Ajami, Ali; Armaghan, Mehdi

    2012-01-01

    Highlights: ► Reactive power and voltage sag are compensated during grid side fault. ► Nonlinear model of UPQC is modified to a linear model. ► Using the CSI in proposed UPQC offers a number of distinct advantages. ► Pitch angle controller is used to obtain nominal power at high wind speeds. ► Optimal control method (LQR) is used to determine the optimal state feedback gains. - Abstract: In this paper, a current-source converter based unified power quality conditioner (UPQC) is used for the flexible integration of pitch controlled fixed speed wind generator (FSWG) to IEEE 13 node test feeder. During the normal operation, shunt compensator (SHUC) of the UPQC maintains a unity power factor condition at the Point of Common Coupling (PCC) and when a voltage sag occurs due to grid side fault the series compensator (SERC) of the UPQC injects appropriate deficit voltage to prevent disconnecting of the FSWG and the SHUC of the UPQC provides additional reactive power in fault during. The pitch angle is controlled in order to limit the generator output power to its nominal value for high wind speeds. The nonlinear model of the shunt compensator of the UPQC is modified to a linear model. The modeling technique is not based on the linearization of a set of nonlinear equations around an operating point. Instead, the power balance equation and a nonlinear input transformation are used to derive a linear model independent of the operating point. This model acts as the basis for the design of a decoupled state-feedback controller. The optimal control method linear quadratic regulator (LQR) is used to determine the optimal state-feedback gain matrix. The proposed control approach becomes a robust strategy that is able to keep regulation and stability even under extreme load power factor variations. The In-phase voltage injection method is used for the series compensator of the UPQC. The simulation results carried out by MATLAB/SIMULINK software show the performance of the

  5. Generalized modular multilevel converter and modulation

    DEFF Research Database (Denmark)

    Liu, Hui; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    converters regulating a power grid. The generalized topology derived and notated as GMMC can then be altered to create various types of MMC, including the traditional topology that is presently well-known. This effort has not been previously discussed, and may smoothen the understanding of MMC operation...

  6. Discontinuous PWM Modulation Strategy with Circuit-Level Decoupling Concept of Three-Level Neutral-Point Clamped (NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2013-01-01

    inverters, but also reduces the switching loss of the inverter along with an inherent neutral point (NP) voltage control. Based on a circuit-level decoupling concept, the NPC inverter can be decoupled into two three-level Buck converters in every defined operating section, and thereby the controller design...... can be reduced by one third. In order to explain the operation of this topology properly, the decoupling principle including the driving signal synthesis and the NP potential variation are analyzed in detail in this paper. Finally the viability and performance of the proposed modulation scheme...

  7. Full-load converter connected asynchronous generators for MW class wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Akhmatov, Vladislav

    2005-06-15

    Wind turbines equipped with full-load converter-connected asynchronous generators are a known concept. These have rating up to hundreds of kW and are a feasible concept for MW class wind turbines and may have advantages when compared to conventional wind turbines with directly connected generators. The concept requires the use of full-scale frequency converters, but the mechanical gearbox is smaller than in conventional wind turbines of the same rating. Application of smaller gearbox may reduce the no-load losses in the wind turbines, which is why such wind turbines with converter connected generators may start operation at a smaller wind speed. Wind turbines equipped with such converted connected asynchronous generators are pitch-controlled and variable-speed. This allows better performance and control. The converter control may be applied to support the grid voltage at short-circuit faults and to improve the fault-ride-through capability of the wind turbines, which makes the concepts relevant for large wind farms. The Danish transmission system operator Energinet-DK has implemented the general model of wind turbines equipped with converter connected asynchronous generators with the simulation tool Powerfactory (DlgSilent). The article presents Energinet-DK's experience of modeling this feasible wind turbine concept. (Author)

  8. Harmonic Issues Assessment on PWM VSC-Based Controlled Microgrids using Newton Methods

    DEFF Research Database (Denmark)

    Agundis-Tinajero, Gibran; Segundo-Ramirez, Juan; Peña-Gallardo, Rafael

    2018-01-01

    This paper presents the application of Newton-based methods in the time-domain for the computation of the periodic steady state solutions of microgrids with multiple distributed generation units, harmonic stability and power quality analysis. Explicit representation of the commutation process...... of the power electronic converters and closed-loop power management strategies are fully considered. Case studies under different operating scenarios are presented: grid-connected mode, islanded mode, variations in the Thevenin equivalent of the grid and the loads. Besides, the close relation between...... the harmonic distortion, steady state performance of the control systems, asymptotic stability and power quality is analyzed in order to evaluate the importance and necessity of using full models in stressed and harmonic distorted scenarios....

  9. Trends of HVDC technology - highly reliable converting equipment

    International Nuclear Information System (INIS)

    Muraoka, Yasuo; Kato, Yasushi; Watanabe, Atsumi; Kano, Takashi; Kawai, Tadao

    1983-01-01

    At present, the DC power transmission in Japan is practically used for the system connection of relatively small capacity, and the reliability of AC-DC converting system has been proven to exceed the world level by the operational results. However, when the application of this system to trunk power transmission of large capacity in future is considered, it is desirable to raise the reliability of converting equipment further and to develop the stabilized control techniques in harmony with connected AC system. Hitachi Ltd. has developed diversified system-related technologies centering around DC power transmission and the techniques for raising the reliability of converting equipment tending to large capacity. In this report, the results and the future prospect are described. The recent trend of DC power transmission, the development of DC power transmission technology such as the simulation analysis, the stable operation of a DC system connected to a weak AC system and the DC independent transmission from nuclear power stations, the technical development of light direct ignition thyristor bulbs and control protection equipment are reported. (Kako, I.)

  10. A tapped-inductor buck-boost converter for a multi-DEAP generator energy harvesting system

    DEFF Research Database (Denmark)

    Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2014-01-01

    the effective operational range of the power electronic converter. In this paper, a bidirectional tapped-inductor buck-boost converter is proposed, addressing high-efficient high step-up and high step-down voltage conversion ratios, for energy harvesting applications based on DEAP generators. The effective...... operational range of the converter is extended, by replacing its high-side switch with a string of three serialized MOSFETs, to accommodate the need for high-efficient high-voltage operation. Experiments conducted on a single DEAP generator - part of a quadruple DEAP generator energy harvesting system...... with all elements installed sequentially in the same circular disk with a 90 phase shift - validate the applicability of the proposed converter, demonstrating energy harvesting of 0.26 J, at 0.5 Hz and 60 % delta-strain; characterized by an energy density of 1.25 J per kg of active material....

  11. A DSP controlled one-to-three phase matrix converter

    Energy Technology Data Exchange (ETDEWEB)

    Dubovsky, J.; Dobrucly, B; Tabacek, R.; Havrila, R. [Department of Electric Traction and Energetics Faculty of Electrical Engineering, University of Zilina (Slovakia)

    1997-12-31

    This paper deals with the theoretical analysis computer simulation and experimental results of IM fed by a one-to-three phase matrix converter which offers a unique solution for single phase electric traction applications. The proposed drive in comparison with currently used conventional drives reduces the number of power switching elements of the converter, which increases drives dependability and brings lower investment in power electronics used in drive. Further advantage is that the converter is controlled with nearly unity power factor which cuts down the operational expenses and offers higher overall performance of the drive. (orig.) 6 refs.

  12. High Efficiency Boost Converter with Three State Switching Cell

    DEFF Research Database (Denmark)

    Klimczak, Pawel; Munk-Nielsen, Stig

    2009-01-01

    is on performance improvement of this type of the converter. Use of foil windings helps to reduce conduction losses in magnetic components and to reduce size of these components. Also it has been demonstrated that the regulation range of this type of converter can be increased by operation with duty cycle lower......The boost converter with the three-state switching cell seems to be a good candidate for a dc-dc stage for non-isolated generators based on alternative energy sources. It provides a high voltage gain, a reduced voltage stress on transistors and limited input current ripples. In this paper the focus...

  13. A modified LLCL-filter with the reduced conducted EMI noise

    DEFF Research Database (Denmark)

    Wu, Weimin; Sun, Yunjie; Lin, Zhe

    2013-01-01

    For a transformerless grid-tied converter using Pulse Width Modulation (PWM), the harmonics of grid-injected current, the leakage current and the Electromagnetic Interference (EMI) noise are three important issues during design of the output filter. In this paper, the Common-Mode (CM...

  14. Convertible bond valuation focusing on Chinese convertible bond market

    OpenAIRE

    Yang, Ke

    2010-01-01

    This paper mainly discusses the methods of valuation of convertible bonds in Chinese market. Different from common convertible bonds in European market, considering the complicate features of Chinese convertible bond, this paper represents specific pricing approaches for pricing convertible bonds with different provisions along with the increment of complexity of these provisions. More specifically, this paper represents the decomposing method and binomial tree method for pricing both of Non-...

  15. Simulation and Implementation a Non-Isolated Buck Converter at ZCS Condition

    Directory of Open Access Journals (Sweden)

    Nahid Hematian

    2013-10-01

    Full Text Available A new soft-switching resonant inverting-buck converter with high efficiency is presented. The proposed converter steps down and inverts the input voltage. The zero-current-switching (ZCS technique is employed to reduce switching losses and Electromagnetic Interferences (EMI. An LLC resonant network is utilized to provide soft-switching conditions for all semiconductor devices. Experimental results verify the integrity of the proposed converter operation and the presented theoretical analysis.

  16. Investigation of DC-DC Boost Converter for Reliability of Operational Planning

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Ashouri, Mani; Silva, Filipe Miguel Faria da

    2018-01-01

    of the interests related to reliability is the power semiconductor switches, which are the most vulnerable elements. The failure of one-power switches can reduce the system reliability. Interleaved technique for DC-DC converters is a redundant strategy to improve the reliability, but at the cost of increasing...

  17. A Bidirectional Resonant DC-DC Converter Suitable for Wide Voltage Gain Range

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Al-Durra, Ahmed

    2018-01-01

    This paper proposes a new bidirectional resonant dc-dc converter suitable for wide voltage gain range applications (e.g., energy storage systems). The proposed converter overcomes the narrow voltage gain range of conventional resonant dc-dc converters, and meanwhile achieves high efficiency...... losses. The operation principles and characteristics of the proposed converter are firstly analyzed in this paper. Then the analytical solutions for the voltage gain, soft-switching, and rms currents are derived, which facilitates the parameters design and optimization. Finally, the proposed topology...... and analysis are verified with experimental results obtained from a 1-kW converter prototype....

  18. Optimum Design of LLC Resonant Converter using Inductance Ratio (Lm/Lr)

    Science.gov (United States)

    Palle, Kowstubha; Krishnaveni, K.; Ramesh Reddy, Kolli

    2017-06-01

    The main benefits of LLC resonant dc/dc converter over conventional series and parallel resonant converters are its light load regulation, less circulating currents, larger bandwidth for zero voltage switching, and less tuning of switching frequency for controlled output. An unique analytical tool, called fundamental harmonic approximation with peak gain adjustment is used for designing the converter. In this paper, an optimum design of the converter is proposed by considering three different design criterions with different values of inductance ratio (Lm/Lr) to achieve good efficiency at high input voltage. The optimum design includes the analysis in operating range, switching frequency range, primary side losses of a switch and stability. The analysis is carried out with simulation using the software tools like MATLAB and PSIM. The performance of the optimized design is demonstrated for a design specification of 12 V, 5 A output operating with an input voltage range of 300-400 V using FSFR 2100 IC of Texas instruments.

  19. Positron imaging with multiwire proportional chamber-gamma converter hybrid detectors

    International Nuclear Information System (INIS)

    Chu, D.Y.H.

    1976-09-01

    A large area positron camera was developed using multiwire proportional chambers as detectors and electromagnetic delay lines for coordinate readout. Honeycomb structured gamma converters made of lead are coupled to the chambers for efficient gamma detection and good spatial resolution. Two opposing detectors, each having a sensitive area of 48 cm x 48 cm, are operated in coincidence for the detection of annihilation gammas (511 keV) from positron emitters. Detection efficiency of 4.2 percent per detector and spatial resolution of 6 to 7 mm FWHM at the mid-plane were achieved. The present camera operates at a maximum count rate of 24 K counts/min, limited by accidental coincidence. The theory for the gamma converter is presented along with a review of the operation of the multiwire proportional chamber and delay line readout. Calculated gamma converter efficiencies are compared with the measured results using a prototype test chamber. The characteristics of the positron camera system is evaluated, and the performance is shown to be consistent with calculation

  20. Analysis of series resonant converter with series-parallel connection

    Science.gov (United States)

    Lin, Bor-Ren; Huang, Chien-Lan

    2011-02-01

    In this study, a parallel inductor-inductor-capacitor (LLC) resonant converter series-connected on the primary side and parallel-connected on the secondary side is presented for server power supply systems. Based on series resonant behaviour, the power metal-oxide-semiconductor field-effect transistors are turned on at zero voltage switching and the rectifier diodes are turned off at zero current switching. Thus, the switching losses on the power semiconductors are reduced. In the proposed converter, the primary windings of the two LLC converters are connected in series. Thus, the two converters have the same primary currents to ensure that they can supply the balance load current. On the output side, two LLC converters are connected in parallel to share the load current and to reduce the current stress on the secondary windings and the rectifier diodes. In this article, the principle of operation, steady-state analysis and design considerations of the proposed converter are provided and discussed. Experiments with a laboratory prototype with a 24 V/21 A output for server power supply were performed to verify the effectiveness of the proposed converter.

  1. QCA Gray Code Converter Circuits Using LTEx Methodology

    Science.gov (United States)

    Mukherjee, Chiradeep; Panda, Saradindu; Mukhopadhyay, Asish Kumar; Maji, Bansibadan

    2018-04-01

    The Quantum-dot Cellular Automata (QCA) is the prominent paradigm of nanotechnology considered to continue the computation at deep sub-micron regime. The QCA realizations of several multilevel circuit of arithmetic logic unit have been introduced in the recent years. However, as high fan-in Binary to Gray (B2G) and Gray to Binary (G2B) Converters exist in the processor based architecture, no attention has been paid towards the QCA instantiation of the Gray Code Converters which are anticipated to be used in 8-bit, 16-bit, 32-bit or even more bit addressable machines of Gray Code Addressing schemes. In this work the two-input Layered T module is presented to exploit the operation of an Exclusive-OR Gate (namely LTEx module) as an elemental block. The "defect-tolerant analysis" of the two-input LTEx module has been analyzed to establish the scalability and reproducibility of the LTEx module in the complex circuits. The novel formulations exploiting the operability of the LTEx module have been proposed to instantiate area-delay efficient B2G and G2B Converters which can be exclusively used in Gray Code Addressing schemes. Moreover this work formulates the QCA design metrics such as O-Cost, Effective area, Delay and Cost α for the n-bit converter layouts.

  2. Triple Line-Voltage Cascaded VIENNA Converter Applied as the Medium-Voltage AC Drive

    Directory of Open Access Journals (Sweden)

    Jia Zou

    2018-04-01

    Full Text Available A novel rectifier based on a triple line-voltage cascaded VIENNA converter (LVC-VC was proposed. Compared to the conventional cascaded H-bridge converters, the switch voltage stress is lower, and the numbers of switches and dc capacitors are fewer under similar operating conditions in the proposed new multilevel converter. The modeling and control for the LVC-VC ware presented. Based on the analysis of the operation principle of the new converter, the power factor correction of the proposed converter was realized by employing a traditional one-cycle control strategy. The minimum average value and maximum harmonic components of the dc-link voltages of the three VIENNA rectifier modules ware calculated. Three VIENNA dc-link voltages were unbalanced under the unbalanced load conditions, so the zero sequence current was injected to the three inner currents for balancing three VIENNA dc-link voltages. Simulation and the results of the experiment verified the availability of the new proposed multilevel converter and the effectiveness of the corresponding control strategy applied.

  3. Feasibility analysis of fuzzy logic control for ITER Poloidal field (PF) AC/DC converter system

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Mahmood Ul; Fu, Peng [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China (China); Song, Zhiquan, E-mail: zhquansong@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Chen, Xiaojiao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China (China); Zhang, Xiuqing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Humayun, Muhammad [Shanghai Jiaotong University (China)

    2017-05-15

    Highlights: • The implementation of the Fuzzy controller for the ITER PF converter system is presented. • The comparison of the FLC and PI simulation are investigated. • The FLC single and parallel bridge operation are presented. • Fuzzification and Defuzzification algorithms are presented using FLC controller. - Abstract: This paper describes the feasibility analysis of the fuzzy logic control to increase the performance of the ITER poloidal field (PF) converter systems. A fuzzy-logic-based controller is designed for ITER PF converter system, using the traditional PI controller and Fuzzy controller (FC), the dynamic behavior and transient response of the PF converter system are compared under normal operation by analysis and simulation. The analysis results show that the fuzzy logic control can achieve better operation performance than PI control.

  4. Interlink Converter with Linear Quadratic Regulator Based Current Control for Hybrid AC/DC Microgrid

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2017-11-01

    Full Text Available A hybrid alternate current/direct current (AC/DC microgrid consists of an AC subgrid and a DC subgrid, and the subgrids are connected through the interlink bidirectional AC/DC converter. In the stand-alone operation mode, it is desirable that the interlink bidirectional AC/DC converter manages proportional power sharing between the subgrids by transferring power from the under-loaded subgrid to the over-loaded one. In terms of system security, the interlink bidirectional AC/DC converter takes an important role, so proper control strategies need to be established. In addition, it is assumed that a battery energy storage system is installed in one subgrid, and the coordinated control of interlink bidirectional AC/DC converter and battery energy storage system converter is required so that the power sharing scheme between subgrids becomes more efficient. For the purpose of designing a tracking controller for the power sharing by interlink bidirectional AC/DC converter in a hybrid AC/DC microgrid, a droop control method generates a power reference for interlink bidirectional AC/DC converter based on the deviation of the system frequency and voltages first and then interlink bidirectional AC/DC converter needs to transfer the power reference to the over-loaded subgrid. For efficiency of this power transferring, a linear quadratic regulator with exponential weighting for the current regulation of interlink bidirectional AC/DC converter is designed in such a way that the resulting microgrid can operate robustly against various uncertainties and the power sharing is carried out quickly. Simulation results show that the proposed interlink bidirectional AC/DC converter control strategy provides robust and efficient power sharing scheme between the subgrids without deteriorating the secure system operation.

  5. Hopf bifurcation and eigenvalue sensitivity analysis of doubly fed induction generator wind turbine system

    DEFF Research Database (Denmark)

    Yang, Li Hui; Xu, Zhao; Østergaard, Jacob

    2010-01-01

    This paper first presents the Hopf bifurcation analysis for a vector-controlled doubly fed induction generator (DFIG) which is widely used in wind power conversion systems. Using three-phase back-to-back pulse-width-modulated (PWM) converters, DFIG can keep stator frequency constant under variabl...

  6. Comparative evaluation of passive damping topologies for parallel grid-connected converters with LCL filters

    DEFF Research Database (Denmark)

    Beres, Remus Narcis; Wang, Xiongfei; Blaabjerg, Frede

    2014-01-01

    that with grid-side current feedback the stability may be improved in parallel operation while for converter-side feedback, the stability of the current controller is always decreased compared with the single converter case. The proposed stability analysis and experimental tests demonstrates the theoretical......In this paper a comprehensive analysis of three passive damping methods is done under parallel operation of multiple current controlled voltage source converters. One could argue that a well damped LCL filter with no peaking in the output impedance and stable designed controllers will turn...

  7. Autonomous Control of Interlinking Converter With Energy Storage in Hybrid AC–DC Microgrid

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Li, Ding; Chai, Yi Kang

    2013-01-01

    , simplicity, and industry relevance of the converter. The desired operating features of the hybrid microgrid can then be added through this interlinking converter. To demonstrate, an appropriate control scheme is now developed for controlling the interlinking converter. The objective is to keep the hybrid......The coexistence of ac and dc subgrids in a hybrid microgrid is likely given that modern distributed sources can either be ac or dc. Linking these subgrids is a power converter, whose topology should preferably be not too unconventional. This is to avoid unnecessary compromises to reliability...... microgrid in autonomous operation with active power proportionally shared among its distributed sources. Power sharing here should depend only on the source ratings and not their placements within the hybrid microgrid. The proposed scheme can also be extended to include energy storage within...

  8. Test strategies for industrial testers for converter controls equipment

    International Nuclear Information System (INIS)

    Oleniuk, P.; Kasampalis, V.; Cosmo, M. Di; Nisbet, D.; Todd, B.; Uznański, S.

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.

  9. Equipment for evaluation of the characteristics of electronic-optic converters

    International Nuclear Information System (INIS)

    Getsov, Petar; Mardirossian, Garo; Nedkov, Rumen; Stoyanov, Stiliyan; Bo, Wang; Prokopenko, Olga; Boyanov, Petar

    2018-01-01

    In this paper we consider the concept, structure, operation and application of original equipment for evaluation of the characteristics of electronic-optic converters (EOC) created in the Space Research and Technologies Institute at the Bulgarian Academy of Sciences. The equipment is recognized as an invention and it is subject to patent protection. Key words: electronic-optic converter, infrared radiation, night surveillance devices

  10. Improvement of burst-mode control of piezoelectric transformer based DC/DC converter

    International Nuclear Information System (INIS)

    Vasic, Dejan; Liu, Yuan-Ping; Costa, François; Schwander, Denis; Wu, Wen-Jong

    2013-01-01

    Burst-mode operation is adopted sometimes in piezoelectric transformer based converters for two major purposes: (1) to achieve voltage regulation in DC/DC converters and (2) to achieve dimming control in backlight inverters. Burst-mode control enables the converter to operate at a constant switching frequency as well as to maintain good efficiency at light load conditions. However, in practice, the piezoelectric transformer cannot instantly stop vibrating in the burst-mode due to its high quality factor. The delay in the output voltage change resulting from this behavior influences the accuracy of the regulation. This paper proposes a control strategy to make the piezoelectric transformer stop more quickly so as to enhance the accuracy of burst-mode control. The proposed method only modifies the control signal of the burst-mode driving circuit. The proposed control strategy is verified by experiments in a step-down 9 W DC/DC converter. (paper)

  11. Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch

    Directory of Open Access Journals (Sweden)

    Yusuke Hayashi

    2016-01-01

    Full Text Available An active gate controlled semiconductor protection switch using SiC-MOSFET is proposed to achieve the fault tolerant operation of ISOP (Input Series and Output Parallel connected multicell dc-dc converter. The SiC-MOSFET with high temperature capability simplifies the configuration of the protection circuit, and its on-resistance control by the active gate controller realizes the smooth protection without the voltage and the current surges. The first laboratory prototype of the protection switch is fabricated by using a SiC-MOSFET with a high frequency buck chopper for the active gate controller. The effectiveness of the proposed protection switch is verified, taking the impact of the volume reduction into account.

  12. Reliability modeling and analysis for a novel design of modular converter system of wind turbines

    International Nuclear Information System (INIS)

    Zhang, Cai Wen; Zhang, Tieling; Chen, Nan; Jin, Tongdan

    2013-01-01

    Converters play a vital role in wind turbines. The concept of modularity is gaining in popularity in converter design for modern wind turbines in order to achieve high reliability as well as cost-effectiveness. In this study, we are concerned with a novel topology of modular converter invented by Hjort, Modular converter system with interchangeable converter modules. World Intellectual Property Organization, Pub. No. WO29027520 A2; 5 March 2009, in this architecture, the converter comprises a number of identical and interchangeable basic modules. Each module can operate in either AC/DC or DC/AC mode, depending on whether it functions on the generator or the grid side. Moreover, each module can be reconfigured from one side to the other, depending on the system’s operational requirements. This is a shining example of full-modular design. This paper aims to model and analyze the reliability of such a modular converter. A Markov modeling approach is applied to the system reliability analysis. In particular, six feasible converter system models based on Hjort’s architecture are investigated. Through numerical analyses and comparison, we provide insights and guidance for converter designers in their decision-making.

  13. Convertible shielding to ceramic breeding blanket

    International Nuclear Information System (INIS)

    Furuya, Kazuyuki; Kurasawa, Toshimasa; Sato, Satoshi; Nakahira, Masataka; Togami, Ikuhide; Hashimoto, Toshiyuki; Takatsu, Hideyuki; Kuroda, Toshimasa.

    1995-05-01

    Four concepts have been studied for the ITER convertible blanket: 1)Layered concept 2)BIT(Breeder-Inside-Tube)concept 3)BOT(Breeder-Out of-Tube)concept 4)BOT/mixed concept. All concepts use ceramic breeder and beryllium neutron multiplier, both in the shape of small spherical pebbles, 316SS structure, and H 2 O coolant (inlet/outlet temperatures : 100/150degC, pressure : 2 MPa). During the BPP, only beryllium pebbles (the primary pebble in case of BOT/mixed concept) are filled in the blanket for shielding purpose. Then, before the EPP operation, breeder pebbles will be additionally inserted into the blanket. Among possible conversion methods, wet method by liquid flow seems expecting for high and homogeneous pebble packing. Preliminary 1-D neutronics calculation shows that the BOT/mixed concept has the highest breeding and shielding performance. However, final selection should be done by R and D's and more detail investigation on blanket characteristics and fabricability. Required R and D's are also listed. With these efforts, the convertible blanket can be developed. However, the following should be noted. Though many of above R and D's are also necessary even for non-convertible blanket, R and D's on convertibility will be one of the most difficult parts and need significant efforts. Besides the installation of convertible blanket with required structures and lines for conversion will make the ITER basic machine more complicated. (author)

  14. Design of coolant distribution system (CDS) for ITER PF AC/DC converter

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Bin [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Song, Zhiquan, E-mail: zhquansong@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Fu, Peng; Xu, Xuesong; Li, Chuan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Wang, Min; Dong, Lin [China International Nuclear Fusion Energy Program Execution Center, Beijing 100862 (China)

    2016-10-15

    Highlights: • System process and arrangement has been proposed to meet the multiple requirements from the converter system. • Thermal hydraulic analysis model has been developed to size and predict the system operation behavior. • Prototype test has been performed to validate the proposed design methodology. - Abstract: The Poloidal Field (PF) converter unit, playing an essential role in the plasma shape and position control in vertical and horizontal direction, which is an important part of ITER power supply system. As an important subsystem of the converter unit, the coolant distribution system has the function to distribute the cooling water from ITER component cooling water system (CCWS) to its main components at the required flow rate, pressure and temperature. This paper presents the thermal hydraulic design of coolant distribution system for the ITER PF converter unit. Different operational requirements of the PF converter unit regarding flow rate, temperature and pressure have been analyzed to design the system process and arrangement. A thermal-hydraulic analysis model has been built to size the system and predict the flow rate and temperature distribution of the system under the normal operation. Based on the system thermal-hydraulic analysis results, the system pressure profile has been plotted to evaluate the pressure behavior along each client flow path. A CDS prototype for the ITER PF converter has been constructed and some experiments have been performed on it. A good agreement of the flow distribution and temperature behavior between the simulated and test results validate the proposed design methodology.

  15. A series-resonant converter used as an amplitude and frequency function generator

    NARCIS (Netherlands)

    Huisman, H.; Gravendeel, B.

    1988-01-01

    A series-resonant power converter system is presented which allows generation of multiphase output voltages with very low distortion at high efficiency. The self-commutated resonant operation mode ensures the converter to be short-circuit proof. After a discussion of the control concept, some

  16. Dynamics and stabilization of peak current-mode controlled buck converter with constant current load

    International Nuclear Information System (INIS)

    Leng Min-Rui; Zhou Guo-Hua; Zhang Kai-Tun; Li Zhen-Hua

    2015-01-01

    The discrete iterative map model of peak current-mode controlled buck converter with constant current load (CCL), containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. (paper)

  17. Development of microheaters for gas sensor with an AT-Mega 8535 temperature controller using a PWM (pulse width modulation) method

    Science.gov (United States)

    Megayanti, Meti; Panatarani, Camellia; Joni, I. Made

    2016-03-01

    Microheater is the main component in gas sensor characterized by their sensitivity, selectivity, and time response of gas sensor which is depend on the microheater temperature stability. A Cu microheater was developed and utilized AT-Mega 8535 controller using a PWM (pulse width modulation) method. This control system is interfaced to the PC to observe the real time temperature response of the microheater. Three initial resistance (R0) variations of microheater were developed in an open loop control system. The power characteristic of designed microheater depends on the specified microheater initial resistance. The smaller R0, the less power required to reach a temperature setting value. The developed microheater was designed to reach a temperature setting value of 250°C having resistance 0.531 Ω for 1.979 Watt and 0.265 Ω for 1.072 Watt respectively. The results of the investigation on the control performances shows microheater-control system achieved operating temperature up to 250°C. The response of the temperature control shows smallest R0 resulted in a high stability with short settling time, short delay time and small ripple for temperature setting values higher than 150°C. The obtained error of microheater temperature with R0 = 0.265 is 8.596 %. It is concluded that the developed microheater can be utilized as a component of a gas sensor.

  18. Development of microheaters for gas sensor with an AT-Mega 8535 temperature controller using a PWM (pulse width modulation) method

    Energy Technology Data Exchange (ETDEWEB)

    Megayanti, Meti; Panatarani, Camellia; Joni, I. Made, E-mail: imadejoni@phys.unpad.ac.id [Instrumentation System and Functional Material Processing Laboratory, Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Padjadjaran Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, West Java (Indonesia)

    2016-03-11

    Microheater is the main component in gas sensor characterized by their sensitivity, selectivity, and time response of gas sensor which is depend on the microheater temperature stability. A Cu microheater was developed and utilized AT-Mega 8535 controller using a PWM (pulse width modulation) method. This control system is interfaced to the PC to observe the real time temperature response of the microheater. Three initial resistance (R0) variations of microheater were developed in an open loop control system. The power characteristic of designed microheater depends on the specified microheater initial resistance. The smaller R0, the less power required to reach a temperature setting value. The developed microheater was designed to reach a temperature setting value of 250°C having resistance 0.531 Ω for 1.979 Watt and 0.265 Ω for 1.072 Watt respectively. The results of the investigation on the control performances shows microheater-control system achieved operating temperature up to 250°C. The response of the temperature control shows smallest R0 resulted in a high stability with short settling time, short delay time and small ripple for temperature setting values higher than 150°C. The obtained error of microheater temperature with R0 = 0.265 is 8.596 %. It is concluded that the developed microheater can be utilized as a component of a gas sensor.

  19. A Temperature-Hardened Sensor Interface with a 12-Bit Digital Output Using a Novel Pulse Width Modulation Technique

    Directory of Open Access Journals (Sweden)

    Emna Chabchoub

    2018-04-01

    Full Text Available A fully integrated sensor interface for a wide operational temperature range is presented. It translates the sensor signal into a pulse width modulated (PWM signal that is then converted into a 12-bit digital output. The sensor interface is based on a pair of injection locked oscillators used to implement a differential time-domain architecture with low sensitivity to temperature variations. A prototype has been fabricated using a 180 nm partially depleted silicon-on-insulator (SOI technology. Experimental results demonstrate a thermal stability as low as 65 ppm/°C over a large temperature range from −20 °C up to 220 °C.

  20. Analysis and Design of High-Order Parallel Resonant Converters

    Science.gov (United States)

    Batarseh, Issa Eid

    1990-01-01

    In this thesis, a special state variable transformation technique has been derived for the analysis of high order dc-to-dc resonant converters. Converters comprised of high order resonant tanks have the advantage of utilizing the parasitic elements by making them part of the resonant tank. A new set of state variables is defined in order to make use of two-dimensional state-plane diagrams in the analysis of high order converters. Such a method has been successfully used for the analysis of the conventional Parallel Resonant Converters (PRC). Consequently, two -dimensional state-plane diagrams are used to analyze the steady state response for third and fourth order PRC's when these converters are operated in the continuous conduction mode. Based on this analysis, a set of control characteristic curves for the LCC-, LLC- and LLCC-type PRC are presented from which various converter design parameters are obtained. Various design curves for component value selections and device ratings are given. This analysis of high order resonant converters shows that the addition of the reactive components to the resonant tank results in converters with better performance characteristics when compared with the conventional second order PRC. Complete design procedure along with design examples for 2nd, 3rd and 4th order converters are presented. Practical power supply units, normally used for computer applications, were built and tested by using the LCC-, LLC- and LLCC-type commutation schemes. In addition, computer simulation results are presented for these converters in order to verify the theoretical results.

  1. Design and development of bipolar 4-quadrant switch-mode power converter for superconducting magnets

    International Nuclear Information System (INIS)

    Yashwant Kumar; Thakur, S.K.; Ghosh, M.K.; Tiwari, T.P.; De, Anirban; Kumari, S.; Saha, S.

    2011-01-01

    A uniform zero crossing magnetic field in a magnet can be achieved by using bipolar power converter with four quadrant operation. A high current bipolar switch-mode power converter (rated ±27 V max , ±7V flat top, ±300A, 100 ppm) has been designed and developed indigenously at VECC Kolkata. Four quadrants operation is accomplished by using power IGBTs in an H-bridge configuration with switching frequency around 20 kHz. The switch-mode power converter is used because of high dynamic response, low output ripple, high efficiency and low input current harmonics. In this paper, circuit topology, function of system components and key system specifications of high current bipolar switch mode power converter is discussed. (author)

  2. Comparative evaluation of bidirectional dual active bridge DC-DC converter variants

    NARCIS (Netherlands)

    Sfakianakis, G.; Everts, J.; Huisman, H.; Lomonova, E.A.

    2016-01-01

    For the realization of DC-DC converters in automotive industry, the Dual Active Bridge (DAB) converter seems to be a promising choice because of its soft-switching and high-power-density capability. Contrary to the traditional 3 level - 3 level (3-3L) DAB, a 3 level - 5 level (3-5L) DAB can operate

  3. Impact of Converter Interfaced Generation and Load on Grid Performance

    Science.gov (United States)

    Ramasubramanian, Deepak

    Alternate sources of energy such as wind, solar photovoltaic and fuel cells are coupled to the power grid with the help of solid state converters. Continued deregulation of the power sector coupled with favorable government incentives has resulted in the rapid growth of renewable energy sources connected to the distribution system at a voltage level of 34.5kV or below. Of late, many utilities are also investing in these alternate sources of energy with the point of interconnection with the power grid being at the transmission level. These converter interfaced generation along with their associated control have the ability to provide the advantage of fast control of frequency, voltage, active, and reactive power. However, their ability to provide stability in a large system is yet to be investigated in detail. This is the primary objective of this research. In the future, along with an increase in the percentage of converter interfaced renewable energy sources connected to the transmission network, there exists a possibility of even connecting synchronous machines to the grid through converters. Thus, all sources of energy can be expected to be coupled to the grid through converters. The control and operation of such a grid will be unlike anything that has been encountered till now. In this dissertation, the operation and behavior of such a grid will be investigated. The first step in such an analysis will be to build an accurate and simple mathematical model to represent the corresponding components in commercial software. Once this bridge has been crossed, conventional machines will be replaced with their solid state interfaced counterparts in a phased manner. At each stage, attention will be devoted to the control of these sources and also on the stability performance of the large power system. This dissertation addresses various concerns regarding the control and operation of a futuristic power grid. In addition, this dissertation also aims to address the issue

  4. Back-to-back converter control of grid-connected wind turbine to mitigate voltage drop caused by faults

    DEFF Research Database (Denmark)

    Hassanzadeh, Fattah; Sangrody, Hossein; Hajizadeh, Amin

    2017-01-01

    Power electronic converters enable wind turbines, operating at variable speed, to generate electricity more efficiently. Among variable speed operating turbine generators, permanent magnetic synchronous generator (PMSG) has got more attentions due to low cost and maintenance requirements...... side converter is designed to improve voltage drop caused by the fault in the grid while maximum available active power of wind turbine system is injected to the grid and the DC link voltage in the converter is regulated. The methodology of the converter control is elaborated in details and its...

  5. Y-source impedance-network-based isolated boost DC/DC converter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Town, Graham; Loh, Poh Chiang

    2014-01-01

    A dc-dc converter with very high voltage gain is proposed in this paper for any medium-power application requiring a high voltage boost with galvanic isolation. The proposed converter topology can be realized using only two switches. With this topology a very high voltage boost can be achieved even...... with a relatively low duty cycle of the switches, and the gain obtainable is presently not matched by any existing impedance network based converter operated at the same duty ratio. The proposed converter has a Y-source impedance network to boost the voltage at the intermediate dc-link side and a push......-pull transformer for square-wave AC inversion and isolation. The voltage-doubler rectifier provides a constant dc voltage at the output stage. A theoretical analysis of the converter is presented, supported by simulation and experimental results. A 250 W down-scaled prototype was implemented in the laboratory...

  6. Ultra-high Efficiency DC-DC Converter using GaN Devices

    DEFF Research Database (Denmark)

    Ramachandran, Rakesh

    2016-01-01

    properties of GaN devices can be utilized in power converters to make them more compact and highly efficient. This thesis entitled “Ultra-high Efficiency DC-DC Converter using GaN devices” focuses on achieving ultra-high conversion efficiency in an isolated dc-dc converter by the optimal utilization of Ga...... for many decades. However, the rate of improvement slowed as the silicon power materials asymptotically approached its theoretical bounds. Compared to Si, wideband gap materials such as Silicon Carbide (SiC) and Gallium Nitride (GaN) are promising semiconductors for power devices due to their superior...... in this thesis. Efficiency measurements from the hardware prototype of both the topologies are also presented in this thesis. Finally, the bidirectional operation of an optimized isolated dc-dc converter is presented. The optimized converter has achieved an ultra-high efficiency of 98.8% in both directions...

  7. RISK ANALYSIS FOR SHIP CONVERTING PROJECT ACCOMPLISHMENT (Case study of KRI KP Converting Project

    Directory of Open Access Journals (Sweden)

    Dimas Endro W

    2013-10-01

    Full Text Available Ship converting has become as prospective activity in ship building area. Operational and economical aspect are the most dominant rationale. Baseon a new fuction of converted ship, a task list which contain several jobs that must be done is listed. This accomplishment schedule not only contain a task list, but also duration for certain job title. In practical apllication job duration is maintained based on experience of project manager.  Further more, total accomplish duration is setted as time accomplishment for the project. This setted time has become reference for the project bid. Occasionaly, if accomplishment time which offered is strict, than schedule slip become as potencial nightmare. For this situation, project manager has had a cristal clearconsideration to select a proper decision wheter he will take the tender offer or not. practically, project mananger has layed on his experience to handle previous project and face  penalty if the project delayed. This paper focussed on how to measure tender offer based on risk analysis, specially for converted ship tender which has a strike time accomplishment.A new application method to analysis proposed tender based on time and penalty parameter has become a topic of this paper.

  8. Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

    DEFF Research Database (Denmark)

    Han, Yang; Luo, Mingyu; Chen, Changqing

    2016-01-01

    The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of the phase-locked loops (PLLs), which is of vital significance for the grid-integration and stable operation of power electronic converters to the electric power systems. However, the open-loop ba...

  9. Practical Design Guidelines of qZSI Based Step-Up DC/DC Converter

    Science.gov (United States)

    Zakis, Janis; Vinnikov, Dmitri; Roasto, Indrek; Jalakas, Tanel

    2010-01-01

    This paper presents some design guidelines for a new voltage fed step-up DC/DC isolated converter. The most significant advantage of proposed converter is voltage buck-boost operation on single stage. The most promising application for proposed converter is in the field of distributed power generation e.g. fuel cells or photovoltaic. The most sensitive issues - such as power losses caused by high currents in the input side of converter and high transient overvoltages across the inverter bridge caused by stray inductances were discussed and solved. The proposals and recommendations to overcome these issues are given in the paper. The Selection and design guidelines of converter elements are proposed and explained. The prototype of proposed converter was built and experimentally tested. Some results are presented and evaluated.

  10. Analysis and Control of Buck-Boost Converter with the Same Input Polarity Based on Novel Energy Factor Evaluation

    Directory of Open Access Journals (Sweden)

    Mahmoud Shaker Nasr

    2017-03-01

    Full Text Available This paper presents firstly a buck-boost circuit with the advantage that its output voltage polarity is the same as the input polarity. The circuit operation is presented and analyzed in different modes of operation. The well known parameters used in evaluation of DC/DC converters like Total Harmonic Distortion THD, Power Factor PF, and Ripple Factor RF have no meaning in DC/DC converters, so it is to introduce efficient concepts to permit a fair evaluation of the converter. This paper present other parameters that can be used to study the characteristics of the converter and gives a real and logic means of its operation. These main parameters are: pumping energy PE, storage energy SE, energy factor EF, and energy losses EL. In addition, the converter efficiency is not considered as 100 % as taken in most analyzing studies. The positive DC/DC buck-boost converter is evaluated according to the new concepts and the system model is deduced for different cases of operation taking into account the resistance of the circuit inductor. The circuit is implemented practically and the presented obtained results show the correct operation under different modes of operation. In addition the control design of the converter is built such that a PI controller with windup is considered. In order to test the effectiveness of the designed control algorithm, the system were exposed to different voltage reference values and the obtained results demonstrate that the system responses for all cases are very acceptable according to the criteria of the control system theory.

  11. Combination solar photovoltaic heat engine energy converter

    Science.gov (United States)

    Chubb, Donald L.

    1987-01-01

    A combination solar photovoltaic heat engine converter is proposed. Such a system is suitable for either terrestrial or space power applications. The combination system has a higher efficiency than either the photovoltaic array or the heat engine alone can attain. Advantages in concentrator and radiator area and receiver mass of the photovoltaic heat engine system over a heat-engine-only system are estimated. A mass and area comparison between the proposed space station organic Rankine power system and a combination PV-heat engine system is made. The critical problem for the proposed converter is the necessity for high temperature photovoltaic array operation. Estimates of the required photovoltaic temperature are presented.

  12. Soft switching resonant converter with duty-cycle control in DC micro-grid system

    Science.gov (United States)

    Lin, Bor-Ren

    2018-01-01

    Resonant converter has been widely used for the benefits of low switching losses and high circuit efficiency. However, the wide frequency variation is the main drawback of resonant converter. This paper studies a new modular resonant converter with duty-cycle control to overcome this problem and realise the advantages of low switching losses, no reverse recovery current loss, balance input split voltages and constant frequency operation for medium voltage direct currentgrid or system network. Series full-bridge (FB) converters are used in the studied circuit in order to reduce the voltage stresses and power rating on power semiconductors. Flying capacitor is used between two FB converters to balance input split voltages. Two circuit modules are paralleled on the secondary side to lessen the current rating of rectifier diodes and the size of magnetic components. The resonant tank is operated at inductive load circuit to help power switches to be turned on at zero voltage with wide load range. The pulse-width modulation scheme is used to regulate output voltage. Experimental verifications are provided to show the performance of the proposed circuit.

  13. Autonomous Operation of a Hybrid AC/DC Microgrid with Multiple Interlinking Converters

    DEFF Research Database (Denmark)

    Peyghami, Saeed; Mokhtari, Hossein; Blaabjerg, Frede

    2018-01-01

    Applying conventional dc-voltage based droop approaches for hybrid ac/dc microgrids interconnected by a single interlinking converter (IC) can properly manage the power flow among ac and dc subgrids. However, due to the effect of line resistances, these approaches may create a circulating power a...

  14. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  15. Multi Channels PWM Controller for Thermoelectric Cooler Using a Programmable Logic Device and Lab-Windows CVI

    Directory of Open Access Journals (Sweden)

    Eli FLAXER

    2008-09-01

    Full Text Available We present a complete design of a multi channels PID controller for Thermoelectric Cooler (TEC using a pulse width modulation (PWM technique implemented by a dedicated programmable logic device (PLD programmed by VHDL. The PID control loop is implemented by software written by National Instrument Lab-Windows CVI. Due to the fact that the implementation is by a VHDL and PLD the design is modular, as a result, the circuit is very compact in size and very low cost as compared to any commercial product. In addition, since the control loop is implemented by software running on a personal computer (PC using a C language, it is easy to adjust the controller to various environmental conditions and for a width range of sensors like: a thermo couple (TC, thermistor, resistance temperature detectors (RTD etc. We demonstrate the performance of this circuit as a controller for a small incubator using thermistor as the temperature sensor.

  16. Switching coordination of distributed dc-dc converters for highly efficient photovoltaic power plants

    Science.gov (United States)

    Agamy, Mohammed; Elasser, Ahmed; Sabate, Juan Antonio; Galbraith, Anthony William; Harfman Todorovic, Maja

    2014-09-09

    A distributed photovoltaic (PV) power plant includes a plurality of distributed dc-dc converters. The dc-dc converters are configured to switch in coordination with one another such that at least one dc-dc converter transfers power to a common dc-bus based upon the total system power available from one or more corresponding strings of PV modules. Due to the coordinated switching of the dc-dc converters, each dc-dc converter transferring power to the common dc-bus continues to operate within its optimal efficiency range as well as to optimize the maximum power point tracking in order to increase the energy yield of the PV power plant.

  17. Sadhana | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    https://www.ias.ac.in/article/fulltext/sadh/042/08/1355-1362 ... A PWM converter is the prime component in many power electronic applications ... insights into other essential engineering aspects of auxiliary subsystems such as start-up, ... schemes could prevent unanticipated failures occurring during the course of research.

  18. A low cost rapid prototype platform for a three phase PFC rectifier application

    DEFF Research Database (Denmark)

    Haase, Frerk; Kouchaki, Alireza; Nymand, Morten

    2015-01-01

    In this paper the design and development of a low cost rapid prototype platform for a Three Phase PFC rectifier application is presented. The active rectifier consists of a SiC-MOSFET based PWM converter and a low cost rapid prototype platform for simulating and implementing the digital control...

  19. Investigation of steel to dielectric transition using microminiature eddy-current converter

    Directory of Open Access Journals (Sweden)

    Malikov Vladimir

    2018-01-01

    Full Text Available The research aims to develop a microminiature converter for electrical steel investigation. The research topic is considered relevant due to the need for evaluation and forecasting of safe operating life of electric steel products. The authors determined the capability to study steel characteristics at different depths based on variations of eddy-current converter amplitude at the steel-dielectric boundary. A microminiature transformer-type converter was designed, which enables to perform local investigations of ferromagnetic materials using eddy-current method based on local studies of the steel electrical conductivity. Having the designed converter as a basis, a hardware-software complex was built to perform experimental studies of steel at the interface boundary. A system was developed for automated converter relocation above the studied object at a specified velocity. Test results are reported for a specimen with continuous and discrete measurements taken at different frequencies. Response dependence of eddy-current converter was found to demonstrate non-linear behavior at steel to dielectric transition. The effect of gap between the eddy-current converter and the test object is investigated.

  20. An Innovative Reconfigurable Integrated Converter Topology Suitable for Distributed Generation

    Directory of Open Access Journals (Sweden)

    Renato Rizzo

    2012-09-01

    Full Text Available The electricity market and environmental concerns, with wide utilization of renewable sources, have improved the diffusion of distributed generation units changing the operations of distribution grids from passive networks to microgrids. A microgrid includes a cluster of electrical loads, energy storage devices and microsources, which provide both power and heat to their local area. A microgrid has usually one connection point to the utility grid through power electronic converters placed at customers’ sites. This paper analyses a Reconfigurable Integrated Converter (RIC used for a domestic microgrid with inputs from the AC mains and photovoltaic arrays, and two DC outputs at different voltage levels. A RIC as a dual-boost DC-DC converter is proposed, modelled and analysed in the paper. The advantages of such a topology in comparison with traditional boost converters are outlined. Reported simulations results give evidence on the controllability of this converter and the capability of achieving the desired voltage outputs with reduced ripple.

  1. Development of a green mode DC/DC converter available to portable nuclear instrument

    International Nuclear Information System (INIS)

    Gao Feiyan; Wu Longxiong; Tan Wei; Tang Yaogeng

    2010-01-01

    A green mode DC/DC converter was developed which suitable to the portable nuclear instrument which is powered by battery and is sometime at stand-by mode. Some updated control approaches such as pseudo-resonant type power supply control and synchronous rectification were adopted to makethe DC/DC converter operate with low power consumption and high efficiency. The test results the battery can be prolonged with this converter. (authors)

  2. H- ion production from different converter materials

    International Nuclear Information System (INIS)

    Leung, K.N.; Ehlers, K.W.

    1984-10-01

    For heating plasmas and for current drive in some fusion reactors, high energy neutral beams may be required. The high neutralization efficiency of H - or D - ions makes them favorable to form neutral atoms with energies in excess of 160 keV. It has been shown that a steady-state H - ion beam with current greater than 1 A can be generated by a surface conversion type source with Mo being used as the converter material. In order to achieve the proper cesium coverage and thereby increasing the H - ion yield, the application of porous cesium-dispensing converters is being investigated. It is also possible to optimize the H - production by choosing the proper converter material. In this paper, we compare the negative ion yield generated by different materials (such as Mo, Ti, V, Nb, Pt, Pd, Rh, Cu, Ta, Al, Au, LaB 6 and stainless-steel) in the pure hydrogen and cesium-hydrogen modes of operation

  3. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers....

  4. Converter Power Density Increase using Low Inductive Integrated DC-link Capacitor/Bus

    DEFF Research Database (Denmark)

    Trintis, Ionut; Franke, Toke; Rannested, Bjørn

    2015-01-01

    The power losses in switching devices have a direct effect on the maximum converter power. For a voltage source converter, the DC-link bus has a major influence on the power loss and safe operating area of the power devices. The Power Ring Film CapacitorTM integrated with an optimized bus structu...

  5. A Voltage and Frequency Control Strategy for Stand-Alone Full Converter Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Andrés Peña Asensio

    2018-02-01

    Full Text Available This paper addresses the design and analysis of a voltage and frequency control (VFC strategy for full converter (FC-based wind energy conversion systems (WECSs and its applicability for the supply of an isolated load. When supplying an isolated load, the role of the back-to-back converters in the FC must change with respect to a grid-connected application. Voltage and frequency are established by the FC line side converter (LSC, while the generator side converter (GSC is responsible for maintaining constant voltage in the DC link. Thus, the roles of the converters in the WECS are inverted. Under such control strategies, the LSC will automatically supply the load power and hence, in order to maintain a stable operation of the WECS, the wind turbine (WT power must also be controlled in a load-following strategy. The proposed VFC is fully modelled and a stability analysis is performed. Then, the operation of the WECS under the proposed VFC is simulated and tested on a real-time test bench, demonstrating the performance of the VFC for the isolated operation of the WECS.

  6. Radiated EMI from power converters

    Directory of Open Access Journals (Sweden)

    Arnautovski-Toševa Vesna

    2005-01-01

    Full Text Available With the continuous increase of switching frequency together with the ongoing trend to higher complexity and functionality, power converters as a part of electronic systems have raised more and more electromagnetic energy pollution to the local system environment. In the same time, stringent demands are imposed on the designers of new circuits that electromagnetic interference (EMI has to be suppressed at its source before it is allowed to propagate into other circuits and systems. In this paper, the authors present a full-wave numerical method for calculation and simulation of electromagnetic field radiated by power converter circuitry. The main objective is to analyze the layout geometry in order to obtain competitive PCB layout that will enable suitably attenuated level of the radiated electric field to safe level. By this it would be possible to ensure reliable operation of the sensitive electronic components in the proximity.

  7. Early Oscillation Detection for DC/DC Converter Fault Diagnosis

    Science.gov (United States)

    Wang, Bright L.

    2011-01-01

    The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.

  8. Boost converter with combined control loop for a stand-alone photovoltaic battery charge system

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Thomsen, Ole Cornelius

    2013-01-01

    frequency avoids perturbations in the load being propagated to the photovoltaic panel and thus deviating the operating point. Linearization of the photovoltaic panel and converter state-space modeling is performed. In order to achieve stable operation under all operating conditions, the photovoltaic panel......The converter control scheme plays an important role in the performance of maximum power point tracking (MPPT) algorithms. In this paper, an input voltage control with double loop for a stand-alone photovoltaic system is designed and tested. The inner current control loop with high crossover...

  9. Analytical Comparison of Dual-Input Isolated dc-dc Converter with an ac or dc Inductor for Renewable Energy Systems

    DEFF Research Database (Denmark)

    Zhang, Zhe; Mira Albert, Maria del Carmen; Andersen, Michael A. E.

    2017-01-01

    This paper presents two configurations of dualinput (DI) or three-port (TPC) isolated dc-dc converters for hybrid renewable energy systems such as photovoltaics and batteries. These two converters are derived by integrating an interleaved boost converter and a single-active bridge converter...... and control perspective, distinct in operation principles, voltage/power transfer functions, loss distributions, soft-switching constraints, and power efficiency under the same operating conditions. Moreover, the inductor design differs greatly between these two cases. In this paper, a comprehensive...

  10. Multi-functional Converter with Integrated Motor Control, Battery Charging and Active Module Balancing for Electric Vehicular Application

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Schaltz, Erik; Teodorescu, Remus

    2014-01-01

    , weight and volume in comparison with other Li-Ion based chemistries. The control of the energy flow has been done through a Modular Multilevel Converter (MMC), which has demonstrated advantages over 2 level converters in terms of efficiency, fault tolerant operation, flexible operation modes. It has been...

  11. 40 CFR 65.45 - External floating roof converted into an internal floating roof.

    Science.gov (United States)

    2010-07-01

    ... External floating roof converted into an internal floating roof. The owner or operator who elects to... 40 Protection of Environment 15 2010-07-01 2010-07-01 false External floating roof converted into an internal floating roof. 65.45 Section 65.45 Protection of Environment ENVIRONMENTAL PROTECTION...

  12. Effect of Short-Circuit Faults in the Back-to-Back Power Electronic Converter and Rotor Terminals on the Operational Behavior of the Doubly-Fed Induction Generator Wind Energy Conversion System

    Directory of Open Access Journals (Sweden)

    Dimitrios G. Giaourakis

    2015-02-01

    Full Text Available This paper deals with the operational behavior of the Doubly-Fed Induction Generator Wind Energy Conversion System under power electronic converter and rotor terminals faulty conditions. More specifically, the effect of the short-circuit fault both in one IGBT of the back-to-back power electronic converter and in rotor phases on the overall system behavior has been investigated via simulation using a system of 2 MW. Finally, the consequences of these faults have been evaluated.

  13. Energy balance measurements for the determination of physical and technical operation parameters of thermionic converters

    International Nuclear Information System (INIS)

    Ritz, K.

    1975-01-01

    An introduction into the fundamental theoretical principles of the thermionic Cs converter is followed by the set-up of a special measuring converter as proposed by J. Bohdansky which permits the defined setting of the electrode distance under service conditions. Measurements thus carried out present quantitative data on efficiency, on energy transfer between the electrodes by means of radiation and heat transfer, and on the actual collector potential, the latter which surprisingly shows a distance dependency. (orig./GG) [de

  14. Underwater Noise from a Wave Energy Converter Is Unlikely to Affect Marine Mammals.

    Directory of Open Access Journals (Sweden)

    Jakob Tougaard

    Full Text Available Underwater noise was recorded from the Wavestar wave energy converter; a full-scale hydraulic point absorber, placed on a jack-up rig on the Danish North Sea coast. Noise was recorded 25 m from the converter with an autonomous recording unit (10 Hz to 20 kHz bandwidth. Median sound pressure levels (Leq in third-octave bands during operation of the converter were 106-109 dB re. 1 μPa in the range 125-250 Hz, 1-2 dB above ambient noise levels (statistically significant. Outside the range 125-250 Hz the noise from the converter was undetectable above the ambient noise. During start and stop of the converter a more powerful tone at 150 Hz (sound pressure level (Leq 121-125 dB re 1 μPa was easily detectable. This tone likely originated from the hydraulic pump which was used to lower the absorbers into the water and lift them out of the water at shutdown. Noise levels from the operating wave converter were so low that they would barely be audible to marine mammals and the likelihood of negative impact from the noise appears minimal. A likely explanation for the low noise emissions is the construction of the converter where all moving parts, except for the absorbers themselves, are placed above water on a jack-up rig. The results may thus not be directly transferable to other wave converter designs but do demonstrate that it is possible to harness wave energy without noise pollution to the marine environment.

  15. Underwater Noise from a Wave Energy Converter Is Unlikely to Affect Marine Mammals.

    Science.gov (United States)

    Tougaard, Jakob

    2015-01-01

    Underwater noise was recorded from the Wavestar wave energy converter; a full-scale hydraulic point absorber, placed on a jack-up rig on the Danish North Sea coast. Noise was recorded 25 m from the converter with an autonomous recording unit (10 Hz to 20 kHz bandwidth). Median sound pressure levels (Leq) in third-octave bands during operation of the converter were 106-109 dB re. 1 μPa in the range 125-250 Hz, 1-2 dB above ambient noise levels (statistically significant). Outside the range 125-250 Hz the noise from the converter was undetectable above the ambient noise. During start and stop of the converter a more powerful tone at 150 Hz (sound pressure level (Leq) 121-125 dB re 1 μPa) was easily detectable. This tone likely originated from the hydraulic pump which was used to lower the absorbers into the water and lift them out of the water at shutdown. Noise levels from the operating wave converter were so low that they would barely be audible to marine mammals and the likelihood of negative impact from the noise appears minimal. A likely explanation for the low noise emissions is the construction of the converter where all moving parts, except for the absorbers themselves, are placed above water on a jack-up rig. The results may thus not be directly transferable to other wave converter designs but do demonstrate that it is possible to harness wave energy without noise pollution to the marine environment.

  16. SIMOVERT - intermediate converter for the enrichment of uranium using the gas-ultracentrifuge

    International Nuclear Information System (INIS)

    Neupaver, H.; Weyer, H.

    1978-08-01

    The Simovert intermediate cycle converter is a series device that has proven itself with over 50,000 hours of converter operation. It needs only a small construction effort, has high efficiency, is readily available and is suitable for work up to the mega watt range and, hence, may be considered for the trend towards bigger cascades

  17. Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

    Energy Technology Data Exchange (ETDEWEB)

    Pfeffer, H. [Fermilab; Flora, B. [Fermilab; Wolff, D. [Fermilab

    2016-01-01

    Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

  18. A Current-Fed Isolated Bidirectional DC-DC Converter

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Wu, Xiaoying; Shen, Yanfeng

    2017-01-01

    This paper proposes a current-fed isolated bidirectional DC-DC converter (CF-IBDC) which has the advantages of wide input voltage range, low input current ripple, low conduction losses, and soft switching over the full operating range. Compared with conventional CF-IBDCs, the voltage spikes...

  19. Application of Simplified Neutral Point Clamped Multilevel Converter in a Small Wind Turbine

    Directory of Open Access Journals (Sweden)

    Mlodzikowski Pawel

    2014-05-01

    Full Text Available In low power distributed generation systems low cost together with the energy quality requirements are a key element. It is known that quality of voltage waveforms generated from multilevel converters is better in comparison with those from two-level. Due to advancements in power electronics and microcontrollers, multilevel converters are being built with the use of integrated power modules thus this type of converters are getting more compact in size. This paper investigates performance of a derivation from the most popular multilevel topology - a neutral point clamped converter (NPC. Applying the idea for simplifying the topology by reducing the number of switches (what came from drives this NPC converter is capable of bidirectional AC/DC/AC operation. For the AC/DC part two schemes are tested: Direct Torque Control Space Vector Modulated and Field Oriented Control but for the DC/AC part a control scheme utilizing the proportional-resonant controller was chosen. Laboratory setup was based on a permanent magnet synchronous generator with control and acquisition completed with the help of dSpace 1005 control box. Experimental verification shows that system operates properly.

  20. A Novel Application of Zero-Current-Switching Quasiresonant Buck Converter for Battery Chargers

    OpenAIRE

    Kuo-Kuang Chen

    2011-01-01

    The main purpose of this paper is to develop a novel application of a resonant switch converter for battery chargers. A zero-current-switching (ZCS) converter with a quasiresonant converter (QRC) was used as the main structure. The proposed ZCS dc–dc battery charger has a straightforward structure, low cost, easy control, and high efficiency. The operating principles and design procedure of the proposed charger are thoroughly analyzed. The optimal values of the resonant components are compute...