WorldWideScience

Sample records for pwm buck converter

  1. A ZVT–ZCT PWM synchronous buck converter with a simple passive auxiliary circuit for reduction of losses and efficiency enhancement

    Directory of Open Access Journals (Sweden)

    S. Shiva Kumar

    2015-06-01

    Full Text Available In this paper, a Zero-Voltage-Transition (ZVT–Zero-Current Transition (ZCT Pulse-width Modulated (PWM synchronous buck converter (SBC, with a simple passive auxiliary circuit is proposed, which reduces the stresses and improves the efficiency by pacifying the conduction losses compared to a traditional PWM converter, typically suitable for photovoltaic applications. The important design feature of ZVT–ZCT PWM SBC converters is placement of resonant components that mollifies the conduction losses. Due to the ZVT–ZCT, the resonant components with low values are used, thereby resulting in the increase of switching frequency. The ZVT–ZCT operation of the proposed converter is presented through theoretical analysis. The characteristics of the proposed converter are verified with the simulation in the PSIM co-simulated with MATLAB/SIMULINK environment and implemented experimentally.

  2. A Novel Soft-Switching Synchronous Buck Converter for Portable Applications

    Directory of Open Access Journals (Sweden)

    Anup Kumar Panda

    2008-01-01

    Full Text Available This paper proposes a zero-voltage-transition (ZVT pulse-width-modulated (PWM synchronous buck converter, which is designed to operate at low voltage and high efficiency typically required for portable systems. A new passive auxiliary circuit that allows the main switch to operate with zero-voltage switching has been incorporated in the conventional PWM synchronous buck converter. The operation principles and a detailed steady-state analysis of the ZVT-PWM synchronous converter implemented with the auxiliary circuit are presented. Besides, the main switch and all of the semiconductor devices operate under soft-switching conditions. Thus, the auxiliary circuit provides a larger overall efficiency. The feasibility of the auxiliary circuit is confirmed by simulation and experimental results.

  3. Decentralized Interleaving of Paralleled Dc-Dc Buck Converters: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rodriguez, Miguel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sinha, Mohit [University of Minnesota; Dhople, Sairaj [University of Minnesota; Poon, Jason [University of California at Berkeley

    2017-09-01

    We present a decentralized control strategy that yields switch interleaving among parallel connected dc-dc buck converters without communication. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work represents the first fully decentralized strategy for switch interleaving of paralleled dc-dc buck converters.

  4. Development of an On-Line Self-Tuning FPGA-PID-PWM Control Algorithm Design for DC-DC Buck Converter in Mobile Applications

    Directory of Open Access Journals (Sweden)

    Ahmed Sabah Al-Araji

    2017-08-01

    Full Text Available This paper presents a new development of an on-line hybrid self-tuning control algorithm of the Field Programmable Gate Array - Proportional Integral Derivative - Pulse Width Modulation (FPGA-PID-PWM controller for DC-DC buck converter which is used in battery operation of mobile applications. The main goal in this work is to propose structure of the hybrid Bees-PSO tuning control algorithm which has a capability of quickly and precisely searching in the global regions in order to obtain optimal gain parameters for the proposed controller to generate the best voltage control action to achieve the desired performance of the Buck converter output. Matlab simulation results and Xilinx development tool Integrated Software Environment (ISE experimental work show the robustness and effectiveness of the proposed on-line hybrid Bees-PSO tuning control algorithm in terms of obtaining smooth and unsaturated state voltage control action and minimizing the tracking voltage error of the Buck converter output. Moreover, the fitness evaluation number is reduced.

  5. Two phase interleaved buck converter for driving high power LEDs

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2011-01-01

    The goal of this paper is to evaluate an interleaved buck topology for driving high current light-emitting diodes. Low output capacitor value allows the use of non-electrolytic capacitors extending the lifetime of the converter. Converter is operated as a constant, regulated current source which...... increases luminous efficacy of LED compared to PWM dimmed system. Because of the low dynamic resistance of LEDs the duty cycle of the converter does not change greatly with controlled current. By setting the input voltage of the buck converter to around twice the voltage of diode strings, converter can...

  6. Simulation comparison of proportional integral derivative and fuzzy logic in controlling AC-DC buck boost converter

    Science.gov (United States)

    Faisal, A.; Hasan, S.; Suherman

    2018-03-01

    AC-DC converter is widely used in the commercial industry even for daily purposes. The AC-DC converter is used to convert AC voltage into DC. In order to obtain the desired output voltage, the converter usually has a controllable regulator. This paper discusses buck boost regulator with a power MOSFET as switching component which is adjusted based on the duty cycle of pulse width modulation (PWM). The main problems of the buck boost converter at start up are the high overshoot, the long peak time and rise time. This paper compares the effectiveness of two control techniques: proportional integral derivative (PID) and fuzzy logic control in controlling the buck boost converter through simulations. The results show that the PID is more sensitive to voltage change than fuzzy logic. However, PID generates higher overshoot, long peak time and rise time. On the other hand, fuzzy logic generates no overshoot and shorter rise time.

  7. Three Phase Six-Switch PWM Buck Rectifier with Power Factor Improvement

    DEFF Research Database (Denmark)

    Zafar Ullah Khan, M; Mohsin Naveed, M.; Hussain, Dil Muhammad Akbar

    2013-01-01

    Conventional Phase Controlled Rectifier injects low order current harmonics into the AC mains. Large size filtering components are required to attenuate these harmonics. In this paper, Three Phase Six-Switch PWM Buck Rectifier[1] is presented which operates at nearly unity power factor and provides...

  8. Interleaved Buck Converter with Variable Number of Active Phases and a Predictive Current Sharing Scheme

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Garcia, O.; Oliver, J. A.

    2008-01-01

    The efficiency of an interleaved Buck converter is typically low at light load conditions because of the switching losses in each of the switching stages. Improvements in the converter efficiency can be achieved by dynamically changing the number of active phases depending on the load current....... This paper addresses the issues related to the transient response of the converter when the number of active phases is changed by a digital control scheme. The problem arises because the current in the individual phases of the interleaved Buck converter will not be equal immediately after the controller has...... changed the number of active phases. This paper proposes a current equalisation scheme that adjusts the duty cycle of each phase in a manner that ensures equal average inductor current in all active phases in one or two PWM periods. The current equalisation scheme relies on the measurement of the output...

  9. Monolithic quasi-sliding-mode controller for SIDO buck converter with a self-adaptive free-wheeling current level

    Science.gov (United States)

    Xiaobo, Wu; Qing, Liu; Menglian, Zhao; Mingyang, Chen

    2013-01-01

    An analog implementation of a novel fixed-frequency quasi-sliding-mode controller for single-inductor dual-output (SIDO) buck converter in pseudo-continuous conduction mode (PCCM) with a self-adaptive freewheeling current level (SFCL) is presented. Both small and large signal variations around the operation point are considered to achieve better transient response so as to reduce the cross-regulation of this SIDO buck converter. Moreover, an internal integral loop is added to suppress the steady-state regulation error introduced by conventional PWM-based sliding mode controllers. Instead of keeping it as a constant value, the free-wheeling current level varies according to the load condition to maintain high power efficiency and less cross-regulation at the same time. To verify the feasibility of the proposed controller, an SIDO buck converter with two regulated output voltages, 1.8 V and 3.3 V, is designed and fabricated in HEJIAN 0.35 μm CMOS process. Simulation and experiment results show that the transient time of this SIDO buck converter drops to 10 μs while the cross-regulation is reduced to 0.057 mV/mA, when its first load changes from 50 to 100 mA.

  10. RANCANG BANGUN SOLAR CHARGE CONTROLLER MENGGUNAKAN SYNCRONOUS NON-INVERTING BUCK-BOOST CONVERTER PADA PANEL SURYA 50 WATT PEAK (WP) BERBASIS ARDUINO NANO V3.0

    OpenAIRE

    Mahrubi, Irfan; Bintoro, Jusuf; Djatmiko, Wisnu

    2018-01-01

    Penelitian ini bertujuan untuk merancang bangun rangkaian synchronous non-inverting buck-boost converter (SNIBBC) untuk solar charge controller guna melakukan manajemen pengisian baterai dan manajemen beban dengan menggunakan Arduino Nano V3.0 ATMega 328. Rancang bangun rangkaian synchronous non-inverting buck-boost converter (SNIBBC) menggunakan empat mosfet yang bekerja secara saling singkron dengan dikontrol oleh pulsa PWM dari Timer1 arduino nano V3.0 ATMega 328 dengan frekuensi 10KHz men...

  11. Large-signal stability analysis of PWM converters

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, P.T. [Philips Labs., Briarcliff Manor, NY (United States); Cho, B.H. [Seoul National Univ. (Korea, Republic of). Dept. of Electrical Engineering

    1995-12-31

    Investigation of the effects of existing nonlinearities on the stability of PWM converters is performed. The bilinear structure, the duty cycle saturation, and the opamp saturation are the principal nonlinearities in PWM converters. These nonlinearities are incorporated in the large-signal analytical models of PWM converters, and the basic input-output stability theory is applied to analyze their stability. Design and optimization of the small-signal loop gains to counteract the undesirable nonlinear effects are also discussed.

  12. Monolithic quasi-sliding-mode controller for SIDO buck converter with a self-adaptive free-wheeling current level

    International Nuclear Information System (INIS)

    Wu Xiaobo; Liu Qing; Zhao Menglian; Chen Mingyang

    2013-01-01

    An analog implementation of a novel fixed-frequency quasi-sliding-mode controller for single-inductor dual-output (SIDO) buck converter in pseudo-continuous conduction mode (PCCM) with a self-adaptive freewheeling current level (SFCL) is presented. Both small and large signal variations around the operation point are considered to achieve better transient response so as to reduce the cross-regulation of this SIDO buck converter. Moreover, an internal integral loop is added to suppress the steady-state regulation error introduced by conventional PWM-based sliding mode controllers. Instead of keeping it as a constant value, the free-wheeling current level varies according to the load condition to maintain high power efficiency and less cross-regulation at the same time. To verify the feasibility of the proposed controller, an SIDO buck converter with two regulated output voltages, 1.8 V and 3.3 V, is designed and fabricated in HEJIAN 0.35 μm CMOS process. Simulation and experiment results show that the transient time of this SIDO buck converter drops to 10 μs while the cross-regulation is reduced to 0.057 mV/mA, when its first load changes from 50 to 100 mA. (semiconductor integrated circuits)

  13. A Novel Application of Zero-Current-Switching Quasiresonant Buck Converter for Battery Chargers

    Directory of Open Access Journals (Sweden)

    Kuo-Kuang Chen

    2011-01-01

    Full Text Available The main purpose of this paper is to develop a novel application of a resonant switch converter for battery chargers. A zero-current-switching (ZCS converter with a quasiresonant converter (QRC was used as the main structure. The proposed ZCS dc–dc battery charger has a straightforward structure, low cost, easy control, and high efficiency. The operating principles and design procedure of the proposed charger are thoroughly analyzed. The optimal values of the resonant components are computed by applying the characteristic curve and electric functions derived from the circuit configuration. Experiments were conducted using lead-acid batteries. The optimal parameters of the resonance components were determined using the load characteristic curve diagrams. These values enable the battery charger to turn on and off at zero current, resulting in a reduction of switching losses. The results of the experiments show that when compared with the traditional pulse-width-modulation (PWM converter for a battery charger, the buck converter with a zero- current-switching quasiresonant converter can lower the temperature of the activepower switch.

  14. Soft-switching PWM full-bridge converters topologies, control, and design

    CERN Document Server

    Ruan, Xinbo

    2014-01-01

    Soft-switching PWM full-bridge converters have been widely used in medium-to-high power dc-dc conversions for topological simplicity, easy control and high efficiency. Early works on soft-switching PWM full-bridge converter by many researchers included various topologies and modulation strategies.  However, these works were scattered, and the relationship among these topologies and modulation strategies had not been revealed. This book intends to describe systematically the soft-switching techniques for pulse-width modulation (PWM) full-bridge converters, including the topologies, control and

  15. Buck Converter with Soft-Switching Cells for PV Panel Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2016-03-01

    Full Text Available In power conversion of photovoltaic (PV energy, a hard-switching buck converter always generates some disadvantages. For example, serious electromagnetic interference (EMI, high switching losses, and stresses on an active switch (metal-oxide-semiconductor-field-effect-transistor, MOSFET, and high reverse-recovery losses of a freewheeling diode result in low conversion efficiency. To release these disadvantages, a buck converter with soft-switching cells for PV panel applications is proposed. To create zero-voltage-switching (ZVS features of the active switches, a simple active soft-switching cell with an inductor, a capacitor, and a MOSFET is incorporated into the proposed buck converter. Therefore, the switching losses and stresses of the active switches and EMI can be reduced significantly. To reduce reverse-recovery losses of a freewheeling diode, a simple passive soft-switching cell with a capacitor and two diodes is implemented. To verify the performance and the feasibility of the proposed buck converter with soft-switching cells for PV panel applications, a prototype soft-switching buck converter is built and implemented by using a maximum-power-point-tracking (MPPT method. Simulated and experimental results are presented from a 100 W soft-switching buck converter for PV panel applications.

  16. Non-Inverting Buck-Boost Converter for Fuel Cell Applications

    DEFF Research Database (Denmark)

    Schaltz, Erik; Rasmussen, Peter Omand; Khaligh, Alireza

    2008-01-01

    Fuel cell DC/DC converters often have to be able to both step-up and step-down the input voltage, and provide a high efficiency in the whole range of output power. Conventional negative output buck-boost and non-inverting buck-boost converters provide both step-up and step-down characteristics....... In this paper the non-inverting buck-boost with either diodes or synchronous rectifiers is investigated for fuel cell applications. Most of previous research does not consider  the parasitic in the evaluation of the converters. In this study, detailed analytical expressions of the efficiencies for the system...

  17. Modeling and Simulation of Buck-Boost Converter with Voltage Feedback Control

    Directory of Open Access Journals (Sweden)

    Zhou Xuelian

    2015-01-01

    Full Text Available In order to design the control system, it is necessary to have an exact model of buck-boost converter. This paper put forward the transfer function model of buck-boost converter by the state-space average method. The open-loop transfer function model of uncompensated system is deduced according to the mathematic model of the buck-boost converter, the controller is designed according to frequency domain. The phase and magnitude margin of the open-loop system of the buck-boost converter with compensator have both been increased. After compensating, this control system has the advantages of small overshoot and short settling time. It can also improve control system’s real time property and anti-interference ability.

  18. Mathematical Modeling and Digital Control of A Hybrid Switching Buck Converter

    Directory of Open Access Journals (Sweden)

    Muhammad Umar Abbasi

    2017-06-01

    Full Text Available The aim of this paper is to describe mathematical modeling and digital control of a hybrid switching buck converter. This converter belongs to a class of so called hybrid switching converters and contains a resonant capacitor, resonant inductor and a diode in addition to original buck converter components. The dc gain of this converter is shown to be independent of resonant branch parameters. Moreover the dc conversion ratio is derived for both ideal case and including main inductor dc resistance. Small signal model of the converter is derived and is shown to be similar to conventional buck converter. Simulation results in SIMPLIS Software as well as experimental results of digital control using an 8 bit STM microcontroller are presented. The potential advantages and applications of this converter are discussed.

  19. Quasi-Resonant Full-Wave Zero-Current Switching Buck Converter Design, Simulation and Application

    OpenAIRE

    Yanik, G.; Isen, E.

    2015-01-01

    —This paper presents a full wave quasi-resonant zerocurrent switching buck converter design, simulation and application. The converter control uses with zero-current switching (ZCS) technique to decrease the switching losses. Comparing to conventional buck converter, resonant buck converter includes a resonant tank equipped with resonant inductor and capacitor. The converter is analyzed in mathematical for each subintervals. Depending on the desired input and output electrical quantities, con...

  20. A Novel Single Switch Transformerless Quadratic DC/DC Buck-Boost Converter

    DEFF Research Database (Denmark)

    Mostaan, Ali; A. Gorji, Saman; N. Soltani, Mohsen

    2017-01-01

    A novel quadratic buck-boost DC/DC converter is presented in this study. The proposed converter utilizes only one active switch and can step-up/down the input voltage, while the existing single switch quadratic buck/boost converters can only work in step-up or step-down mode. First, the proposed ...

  1. Assessment of an Average Controller for a DC/DC Converter via Either a PWM or a Sigma-Delta-Modulator

    Directory of Open Access Journals (Sweden)

    R. Silva-Ortigoza

    2014-01-01

    Full Text Available Sliding mode control is a discontinuous control technique that is, by its nature, appropriate for controlling variable structure systems, such as the switch regulated systems employed in power electronics. However, when designing control laws based on the average models of these systems a modulator is necessary for their experimental implementation. Among the most widely used modulators in power electronics are the pulse width modulation (PWM and, more recently, the sigma-delta-modulator (Σ-Δ-modulator. Based on the importance of achieving an appropriate implementation of average control laws and the relevance of the trajectory tracking task in DC/DC power converters, for the first time, this research presents the assessment of the experimental results obtained when one of these controllers is implemented through either a PWM or a Σ-Δ-modulator to perform such a task. A comparative assessment based on the integral square error (ISE index shows that, at frequencies with similar efficiency, the Σ-Δ-modulator provides a better tracking performance for the DC/DC Buck converter. In this paper, an average control based on differential flatness was used to perform the experiments. It is worth mentioning that a different trajectory tracking controller could have been selected for this research.

  2. Accurate Sliding-Mode Control System Modeling for Buck Converters

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper shows that classical sliding mode theory fails to correctly predict the output impedance of the highly useful sliding mode PID compensated buck converter. The reason for this is identified as the assumption of the sliding variable being held at zero during sliding mode, effectively...... approach also predicts the self-oscillating switching action of the sliding-mode control system correctly. Analytical findings are verified by simulation as well as experimentally in a 10-30V/3A buck converter....

  3. A zero-voltage-switched three-phase interleaved buck converter

    Science.gov (United States)

    Hsieh, Yao-Ching; Huang, Bing-Siang; Lin, Jing-Yuan; Pham, Phu Hieu; Chen, Po-Hao; Chiu, Huang-Jen

    2018-04-01

    This paper proposes a three-phase interleaved buck converter which is composed of three identical paralleled buck converters. The proposed solution has three shunt inductors connected between each other of three basic buck conversion units. With the help of the shunt inductors, the MOSFET parasitic capacitances will resonate to achieve zero-voltage-switching. Furthermore, the decreasing rate of the current through the free-wheeling diodes is limited, and therefore, their reverse-recovery losses can be minimised. The active power switches are controlled by interleaved pulse-width modulation signals to reduce the input and output current ripples. Therefore, the filtering capacitances on the input and output sides can be reduced. The power efficiency is measured to be as high as 98% in experiment with a prototype circuit.

  4. Logo2PWM: a tool to convert sequence logo to position weight matrix.

    Science.gov (United States)

    Gao, Zhen; Liu, Lu; Ruan, Jianhua

    2017-10-03

    position weight matrix (PWM) and sequence logo are the most widely used representations of transcription factor binding site (TFBS) in biological sequences. Sequence logo - a graphical representation of PWM, has been widely used in scientific publications and reports, due to its easiness of human perception, rich information, and simple format. Different from sequence logo, PWM works great as a precise and compact digitalized form, which can be easily used by a variety of motif analysis software. There are a few available tools to generate sequence logos from PWM; however, no tool does the reverse. Such tool to convert sequence logo back to PWM is needed to scan a TFBS represented in logo format in a publication where the PWM is not provided or hard to be acquired. A major difficulty in developing such tool to convert sequence logo to PWM is to deal with the diversity of sequence logo images. We propose logo2PWM for reconstructing PWM from a large variety of sequence logo images. Evaluation results on over one thousand logos from three sources of different logo format show that the correlation between the reconstructed PWMs and the original PWMs are constantly high, where median correlation is greater than 0.97. Because of the high recognition accuracy, the easiness of usage, and, the availability of both web-based service and stand-alone application, we believe that logo2PWM can readily benefit the study of transcription by filling the gap between sequence logo and PWM.

  5. The Model and Quadratic Stability Problem of Buck Converter in DCM

    Directory of Open Access Journals (Sweden)

    Li Xiaojing

    2016-01-01

    Full Text Available Quadratic stability is an important performance for control systems. At first, the model of Buck Converter in DCM is built based on the theories of hybrid systems and switched linear systems primarily. Then quadratic stability of SLS and hybrid feedback switching rule are introduced. The problem of Buck Converter’s quadratic stability is researched afterwards. In the end, the simulation analysis and verification are provided. Both experimental verification and theoretical analysis results indicate that the output of Buck Converter in DCM has an excellent performance via quadratic stability control and switching rules.

  6. Generalized Switched-Inductor Based Buck-Boost Z-H Converter

    Directory of Open Access Journals (Sweden)

    E. Babaei

    2017-12-01

    Full Text Available In this paper, a generalized buck-boost Z-H converter based on switched inductors is proposed. This structure consists of a set of series connected switched-inductor cells. The voltage conversion ratio of the proposed structure is adjusted by changing the number of cells and the duty cycle. Like the conventional Z-H converter, the shoot-through switching state and the diode before LC network are eliminated. The proposed converter can provide high voltage gain in low duty cycles. Considering different values for duty cycle, the proposed structure works in two operating zones. In the first operating zone, it works as a buck-boost converter and in the second operating zone, it works as a boost converter. In this paper, a complete analysis of the proposed converter is presented. In order to confirm the accuracy of mathematic calculations, the simulations results by using PSCAD/EMTDC software are given.

  7. A Bond Graph Approach for the Modeling and Simulation of a Buck Converter

    Directory of Open Access Journals (Sweden)

    Rached Zrafi

    2018-01-01

    Full Text Available This paper deals with the modeling of bond graph buck converter systems. The bond graph formalism, which represents a heterogeneous formalism for physical modeling, is used to design a sub-model of a power MOSFET and PiN diode switchers. These bond graph models are based on the device’s electrical elements. The application of these models to a bond graph buck converter permit us to obtain an invariant causal structure when the switch devices change state. This paper shows the usefulness of the bond graph device’s modeling to simulate an implicit bond graph buck converter.

  8. Development of a current-type PWM converter with high power factor. 1

    International Nuclear Information System (INIS)

    Miura, Yushi; Matsukawa, Makoto; Miyachi, Kengo; Kimura, Toyoaki

    1998-01-01

    A power supply system for superconducting poloidal field coils of a next generation tokamak-type fusion device can be operated on the relatively low voltage for the duration of discharge except the plasma initiation. In the case of the conventional phase-controlled thyristor converters are adopted in such a system, the input power factor would be low in average, and a reactive power fluctuation caused by the change of DC output voltage may produce serious effects on the commercial transmission line. From the above viewpoint, a current-type PWM (Pulse Width Modulation) converter, which can work with the power factor of unity for the input power, is regarded as one of the promising candidates of the converters for the power supplies of next generation fusion devices. Hence, a 100kW-class current-type PWM converter has been developed by using IGBT (Insulated Gate Bipolar Transistor) as switching devices. In this development, the basic performance has been preliminary investigated whether this converter is applicable to the power supply for the next generation fusion device. In addition, two different PWM control methods were examined whether these methods can realize a unit power factor and suppress the transient oscillation of converter input current at the same time in case that the reference of DC output current is changed rapidly. (author)

  9. ASDTIC control and standardized interface circuits applied to buck, parallel and buck-boost dc to dc power converters

    Science.gov (United States)

    Schoenfeld, A. D.; Yu, Y.

    1973-01-01

    Versatile standardized pulse modulation nondissipatively regulated control signal processing circuits were applied to three most commonly used dc to dc power converter configurations: (1) the series switching buck-regulator, (2) the pulse modulated parallel inverter, and (3) the buck-boost converter. The unique control concept and the commonality of control functions for all switching regulators have resulted in improved static and dynamic performance and control circuit standardization. New power-circuit technology was also applied to enhance reliability and to achieve optimum weight and efficiency.

  10. Elimination of output voltage oscillations in DC-DC converter using PWM with PI controller

    Directory of Open Access Journals (Sweden)

    Sreenivasappa Veeranna Bhupasandra

    2010-01-01

    Full Text Available In this paper the SIMULINK model of a PWM controlled DC-DC converter is modeled using switching function concept to control the speed of the DC motor. The presence of the voltage oscillation cycles due to higher switching frequency in the DC-DC converter is identified. The effect of these oscillations on the output voltage of the converter, Armature current, Developed torque and Speed of the DC motor is analyzed. In order to minimize the oscillation cycles the PI controller is proposed in the PWM controller.

  11. A Reconfigurable Buck, Boost, and Buck-Boost Converter: Unified Model and Robust Controller

    Directory of Open Access Journals (Sweden)

    Martín Antonio Rodríguez Licea

    2018-01-01

    Full Text Available The need for reconfigurable, high power density, and low-cost configurations of DC-DC power electronic converters (PEC in areas such as the transport electrification and the use of renewable energy has spread out the requirement to incorporate in a single circuit several topologies, which generally result in an increment of complexity about the modeling, control, and stability analyses. In this paper, a reconfigurable topology is presented which can be applied in alterative/changing power conversion scenarios and consists of a reconfigurable Buck, Boost, and Buck-Boost DC-DC converter (RBBC. A unified averaged model of the RBBC is obtained, a robust controller is designed through a polytopic representation, and a Lyapunov based switched stability analysis of the closed-loop system is presented. The reported RBBC provides a wide range of voltage operation, theoretically from -∞ to ∞ volts with a single power source. Robust stability, even under arbitrarily fast (bounded parameter variations and reconfiguration changes, is reported including numerical and experimental results. The main advantages of the converter and the robust controller proposed are simple design, robustness against abrupt changes in the parameters, and low cost.

  12. Circuit Simulation for Solar Power Maximum Power Point Tracking with Different Buck-Boost Converter Topologies

    Directory of Open Access Journals (Sweden)

    Jaw-Kuen Shiau

    2014-08-01

    Full Text Available The power converter is one of the essential elements for effective use of renewable power sources. This paper focuses on the development of a circuit simulation model for maximum power point tracking (MPPT evaluation of solar power that involves using different buck-boost power converter topologies; including SEPIC, Zeta, and four-switch type buck-boost DC/DC converters. The circuit simulation model mainly includes three subsystems: a PV model; a buck-boost converter-based MPPT system; and a fuzzy logic MPPT controller. Dynamic analyses of the current-fed buck-boost converter systems are conducted and results are presented in the paper. The maximum power point tracking function is achieved through appropriate control of the power switches of the power converter. A fuzzy logic controller is developed to perform the MPPT function for obtaining maximum power from the PV panel. The MATLAB-based Simulink piecewise linear electric circuit simulation tool is used to verify the complete circuit simulation model.

  13. Step-down switched-capacitor quasi-resonant PWM converter with continuous conversion ratio

    NARCIS (Netherlands)

    Turhan, M.; Hendrix, M.A.M.; Duarte, J.L.

    2015-01-01

    Inherent disadvantages of conventional switched-capacitor converters (SCC) are their discrete conversion ratio and inefficient energy transfer. In order to soften these downsides, a step-down switched-capacitor quasi-resonant PWM converter is proposed. The operation modes and steady-state

  14. Bi-Frequency Modulated Quasi-Resonant Converters: Theory and Applications

    Science.gov (United States)

    Zhang, Yuefeng

    1995-01-01

    To avoid the variable frequency operation of quasi -resonant converters, many soft-switching PWM converters have been proposed, all of them require an auxiliary switch, which will increase the cost and complexity of the power supply system. In this thesis, a new kind of technique for quasi -resonant converters has been proposed, which is called the bi-frequency modulation technique. By operating the quasi-resonant converters at two switching frequencies, this technique enables quasi-resonant converters to achieve the soft-switching, at fixed switching frequencies, without an auxiliary switch. The steady-state analysis of four commonly used quasi-resonant converters, namely, ZVS buck, ZCS buck, ZVS boost, and ZCS boost converter has been presented. Using the concepts of equivalent sources, equivalent sinks, and resonant tank, the large signal models of these four quasi -resonant converters were developed. Based on these models, the steady-state control characteristics of BFM ZVS buck, BFM ZCS buck, BFM ZVS boost, and BFM ZCS boost converter have been derived. The functional block and design consideration of the bi-frequency controller were presented, and one of the implementations of the bi-frequency controller was given. A complete design example has been presented. Both computer simulations and experimental results have verified that the bi-frequency modulated quasi-resonant converters can achieve soft-switching, at fixed switching frequencies, without an auxiliary switch. One of the application of bi-frequency modulation technique is for EMI reduction. The basic principle of using BFM technique for EMI reduction was introduced. Based on the spectral analysis, the EMI performances of the PWM, variable-frequency, and bi-frequency modulated control signals was evaluated, and the BFM control signals show the lowest EMI emission. The bi-frequency modulated technique has also been applied to the power factor correction. A BFM zero -current switching boost converter has

  15. Bifurcation and Chaos in a Pulse Width modulation controlled Buck Converter

    DEFF Research Database (Denmark)

    Kocewiak, Lukasz; Bak, Claus Leth; Munk-Nielsen, Stig

    2007-01-01

    by a system of piecewise-smooth nonautonomous differential equations. The research are focused on chaotic oscillations analysis and analytical search for bifurcations dependent on parameter. The most frequent route to chaos by the period doubling is observed in the second order DC-DC buck converter. Other...... bifurcations as a complex behaviour in power electronic system evidence are also described. In order to verify theoretical study the experimental DC-DC buck converter was build. The results obtained from three sources were presented and compared. A very good agreement between theory and experiment was observed....

  16. A Review on Direct Power Control for Applications to Grid Connected PWM Converters

    Directory of Open Access Journals (Sweden)

    T. A. Trivedi

    2015-08-01

    Full Text Available The Direct Power Control strategy has become popular as an alternative to the conventional vector oriented control strategy for grid connected PWM converters. In this paper, Direct Power Control as applied to various applications of grid connected converters is reviewed. The Direct Power Control for PWM rectifiers, Grid Connected DC/AC inverters applications such as renewable energy sources interface, Active Power Filters, Doubly Fed Induction Generators and AC-DC-AC converters are discussed. Control strategies such as Look-Up table based control, predictive control, Virtual Flux DPC, Model based DPC and DPC-Space Vector Modulation are critically reviewed. The effects of various key parameters such as selection of switching vector, sampling time, hysteresis band and grid interfacing on performance of direct power controlled converters are presented.

  17. Research on Single-Phase PWM Converter with Reverse Conducting IGBT Based on Loss Threshold Desaturation Control

    Directory of Open Access Journals (Sweden)

    Xianjin Huang

    2017-11-01

    Full Text Available In the application of vehicle power supply and distributed power generation, there are strict requirements for the pulse width modulation (PWM converter regarding power density and reliability. When compared with the conventional insulated gate bipolar transistor (IGBT module, the Reverse Conducting-Insulated Gate Bipolar Transistor (RC-IGBT with the same package has a lower thermal resistance and higher current tolerance. By applying the gate desaturation control, the reverse recovery loss of the RC-IGBT diode may be reduced. In this paper, a loss threshold desaturation control method is studied to improve the output characteristics of the single-phase PWM converter with a low switching frequency. The gate desaturation control characteristics of the RC-IGBT’s diode are studied. A proper current limit is set to avoid the ineffective infliction of the desaturation pulse, while the bridge arm current crosses zero. The expectation of optimized loss decrease is obtained, and the better performance for the RC-IGBTs of the single-phase PWM converter is achieved through the optimized desaturation pulse distribution. Finally, the improved predictive current control algorithm that is applied to the PWM converter with RC-IGBTs is simulated, and is operated and tested on the scaled reduced power platform. The results prove that the gate desaturation control with the improved predictive current algorithm may effectively improve the RC-IGBT’s characteristics, and realize the stable output of the PWM converter.

  18. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  19. Analysis, control and design of a non-inverting buck-boost converter

    DEFF Research Database (Denmark)

    Almasi, Omid Naghash; Fereshtehpoor, Vahid; Khooban, Mohammad Hassan

    2017-01-01

    In this paper, a new modified fuzzy Two-Level Control Scheme (TLCS) is proposed to control a non-inverting buck-boost converter. Each level of fuzzy TLCS consists of a tuned fuzzy PI controller. In addition, a Takagi–Sugeno–Kang (TSK) fuzzy switch proposed to transfer the fuzzy PI controllers...... to eliminate these oscillations and improve the system performance. Some simulations and digital signal processor based experiments are conducted on a non-inverting buck-boost converter to support the effectiveness of the proposed TLCS in controlling the converter output voltage....... to each other in the control system. The major difficulty in designing fuzzy TLCS which degrades its performance is emerging unwanted drastic oscillations in the converter output voltage during replacing the controllers. Thereby, the fuzzy PI controllers in each level of TLCS structure are modified...

  20. Soft switching PWM isolated boost converter for fuel cell application

    Energy Technology Data Exchange (ETDEWEB)

    Rezaei, M.; Adib, E. [Isfahan Univ. of Technology, Isfahan (Iran, Islamic Republic of)

    2009-07-01

    This presentation introduced a newly developed soft switching, isolated boost type converter for fuel cell applications. With a simple PWM control circuit, the converter achieves zero voltage switching the main switch. Since the auxiliary circuit is soft switched, the converter can operate at high powers which make it suitable for fuel cell applications. In particular, the converter is suitable for the interface of fuel cell and inverters because of its high voltage gain and isolation between input and output sources. In addition, the input current of the converter (current drained from the fuel cell) is almost constant since it is a boost type converter. The converter was analyzed and the simulation results validate the theoretical analysis.

  1. A Two-Phase Buck Converter with Optimum Phase Selection for Low Power Applications

    OpenAIRE

    Yeago, Taylor Craig

    2015-01-01

    Power consumption of smart cameras varies significantly between sleep mode and active mode, and a smart camera operates in sleep mode for 80 ��" 90% of time for typical use. To prolong the battery life of smart cameras, it is essential to increase the power converter efficiency for light load, while being able to manage heavy load. The power stage of traditional buck converter is optimized for maximum load, at the cost of light-load efficiency. Wei proposed a multiphase buck converter incorpo...

  2. Soft Switching Full-Bridge PWM DC/DC Converter Using Secondary Snubber

    Directory of Open Access Journals (Sweden)

    Jaroslav Dudrik

    2009-05-01

    Full Text Available A novel full-bridge PWM DC/DCconverter with controlled secondary side rectifier usingsecondary snubber is presented in this paper.Limitation of the circulating current as well as softswitching for all power switches of the inverter isachieved for full load range from no-load to shortcircuit by using controlled rectifier and snubber on thesecondary side. Phase shift PWM control strategy isused for the converter. The principle of operation isexplained and analyzed and the experimental resultson a 1kW, 50 kHz laboratory model of the converterare presented.

  3. Component-Minimized Buck-Boost Voltage Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    This paper presents the design of buck-boost B4 inverters that can be derived from either Ćuk- or SEPIC-derived buck-boost B6 inverters. Unlike traditional inverters, the integration of front-end voltage boost circuitry and inverter circuitry allows it to perform buck-boost voltage inversion...... between capacitors. Modulation wise, the proposed buck-boost B4 inverters can be controlled using a carefully designed carrier-based pulse-width modulation (PWM) scheme that will always ensure balanced threephase outputs as desired, while simultaneously achieving minimal voltage stress across...

  4. Modeling and the analysis of control logic for a digital PWM controller based on a nano electronic single electron transistor

    Directory of Open Access Journals (Sweden)

    Rathnakannan Kailasam

    2008-01-01

    Full Text Available This paper describes the modelling and the analysis of control logic for a Nano-Device- based PWM controller. A comprehensive simple SPICE schematic model for Single Electron transistor has been proposed. The operation of basic Single Electron Transistor logic gates and SET flip flops were successfully designed and their performances analyzed. The proposed design for realizing the logic gates and flip-flops is used in constructing the PWM controller utilized for switching the buck converter circuit. The output of the converter circuit is compared with reference voltage, and when the error voltage and the reference are matched the latch is reset so as to generate the PWM signal. Due to the simplicity and accuracy of the compact model, the simulation time and speed are much faster, which makes it potentially applicable in large-scale circuit simulation. This study confirms that the SET-based PWM controller is small in size, consumes ultra low power and operates at high speeds without compromising any performance. In addition these devices are capable of measuring charges of extremely high sensitivity.

  5. Switch mode power supply

    International Nuclear Information System (INIS)

    Kim, Hui Jun

    1993-06-01

    This book concentrates on switch mode power supply. It has four parts, which are introduction of switch mode power supply with DC-DC converter such as Buck converter boost converter, Buck-boost converter and PWM control circuit, explanation for SMPS with DC-DC converter modeling and power mode control, resonance converter like resonance switch, converter, multi resonance converter and series resonance and parallel resonance converters, basic test of SMPS with PWM control circuit, Buck converter, Boost converter, flyback converter, forward converter and IC for control circuit.

  6. Application of Theory of Hybrid Systems to Control the Switching of Buck Converter

    KAUST Repository

    Benmiloud, Mohammed; Benalia, Atallah; Laleg-Kirati, Taous-Meriem

    2013-01-01

    The field of power electronics poses challenging control problems that can’t be treated in a complete manner using traditional modeling. In this paper, the buck converter operating in Continuous Conduction Mode (CCM) is represented analytically by hybrid automaton model and graphically representation is also given. The hybrid trajectory and the model behavior are presented. The control problem of buck switching converters is transformed to a guard selection problem. The guard selection calculation formulas of buck converter are derived from the basic circuit laws. The stability of the switching is established analytically by the use of multiple Lyapunov functions to ensure the convergence and Poincare map to assess the local stability of the limit cycle. Numerical results clearly bring out the advantages and effectiveness of the proposed control law under varying line voltage and load conditions. Simulation studies are carried out in Matlab/Simulink/Stateflow.

  7. Application of Theory of Hybrid Systems to Control the Switching of Buck Converter

    KAUST Repository

    Benmiloud, Mohammed

    2013-08-01

    The field of power electronics poses challenging control problems that can’t be treated in a complete manner using traditional modeling. In this paper, the buck converter operating in Continuous Conduction Mode (CCM) is represented analytically by hybrid automaton model and graphically representation is also given. The hybrid trajectory and the model behavior are presented. The control problem of buck switching converters is transformed to a guard selection problem. The guard selection calculation formulas of buck converter are derived from the basic circuit laws. The stability of the switching is established analytically by the use of multiple Lyapunov functions to ensure the convergence and Poincare map to assess the local stability of the limit cycle. Numerical results clearly bring out the advantages and effectiveness of the proposed control law under varying line voltage and load conditions. Simulation studies are carried out in Matlab/Simulink/Stateflow.

  8. Sliding-Mode Control Design of a Boost-Buck Switching Converter for AC Signal Generation

    OpenAIRE

    Biel Solé, Domingo; Guinjoan Gispert, Francisco; Fossas Colet, Enric; Chavarría Roé, Javier

    2004-01-01

    This paper presents a sliding-mode control design of a boost–buck switching converter for a voltage step-up dc–ac conversion without the use of any transformer. This approach combines the step-up/step-down conversion ratio capability of the converter with the robustness properties of sliding-mode control. The proposed control strategy is based on the design of two slidingcontrol laws, one ensuring the control of a full-bridge buck converter for proper dc–ac conversion, and the other one the c...

  9. The harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter.

    OpenAIRE

    ПАНЧЕНКО, В В

    2015-01-01

    The author investigates a rectifier unit constructed on the basis of cascade connection of the main non-controlled m-pulse rectifier and PWM voltage booster converter. The research presents the analysis of the harmonic composition of the output voltage of a rectifier unit with a PWM voltage booster converter on completely controlled keys. The dependence of the relative harmonic amplitude on the commutation corner is defined. The estimation of a rectifier unit electromagnetic compatibility wit...

  10. Research procedure for buck-boost converter for small electric vehicles

    Science.gov (United States)

    Vacheva, Gergana; Hinov, Nikolay; Penev, Dimitar

    2017-12-01

    In the current paper is developed a mathematical model realized in Matlab for describing a buck-boost converter for control of small electric vehicle. The model is presented with differential equations which describes the processes in the converter. Through the research of this model it can be accomplished the optimal work mode of a small electric vehicles. The proposed converter can be used in a wide range of applications like small electric vehicles, smart grids and different systems for energy storage.

  11. Research on Two-channel Interleaved Two-stage Paralleled Buck DC-DC Converter for Plasma Cutting Power Supply

    DEFF Research Database (Denmark)

    Yang, Xi-jun; Qu, Hao; Yao, Chen

    2014-01-01

    As for high power plasma power supply, due to high efficiency and flexibility, multi-channel interleaved multi-stage paralleled Buck DC-DC Converter becomes the first choice. In the paper, two-channel interleaved two- stage paralleled Buck DC-DC Converter powered by three-phase AC power supply...

  12. Simulation and Implementation a Non-Isolated Buck Converter at ZCS Condition

    Directory of Open Access Journals (Sweden)

    Nahid Hematian

    2013-10-01

    Full Text Available A new soft-switching resonant inverting-buck converter with high efficiency is presented. The proposed converter steps down and inverts the input voltage. The zero-current-switching (ZCS technique is employed to reduce switching losses and Electromagnetic Interferences (EMI. An LLC resonant network is utilized to provide soft-switching conditions for all semiconductor devices. Experimental results verify the integrity of the proposed converter operation and the presented theoretical analysis.

  13. New PWM method and commutation strategy for HF-link converters for fuel cells and photovoltaics

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a new PWM method and commutation strategy for HF-link converters, which leads to safe commutation of the load current in the output bidirectional bridge. The proposed implementation is independent of the particular HF-link converter topology and bidirectional switch selection ...

  14. Atmel Microcontroller Based Soft Switched PWM ZVS Full Bridge DC to DC Converter

    Directory of Open Access Journals (Sweden)

    DEEPAK KUMAR NAYAK

    2010-12-01

    Full Text Available This paper deals with the simulation and implementation of soft switched PWM ZVS full bridge DC to DC converter. The 48V DC is efficiently reduced to 12V DC using a DC to DC converter. This converter has advantages like reduced switching losses, stresses and EMI. Input DC is converted into high frequency AC and it is stepped down to 12V level. Later it is rectified using a full wave rectifier. Laboratory model of microcontroller based DC to DC converter is fabricated and tested. The experimental results are compared with the simulation results.

  15. Cross-Regulation Assessment of DIDO Buck-Boost Converter for Renewable Energy Application

    Directory of Open Access Journals (Sweden)

    Deepak Elamalayil Soman

    2017-06-01

    Full Text Available When medium- or high-voltage power conversion is preferred for renewable energy sources, multilevel power converters have received much of the interest in this area as methods for enhancing the conversion efficiency and cost effectiveness. In such cases, multilevel, multi-input multi-output (MIMO configurations of DC-DC converters come to the scenario for integrating several sources together, especially considering the stringent regulatory needs and the requirement of multistage power conversion systems. Considering the above facts, a three-level dual input dual output (DIDO buck-boost converter, as the simplest form of MIMO converter, is proposed in this paper for DC-link voltage regulation. The capability of this converter for cross regulating the DC-link voltage is analyzed in detail to support a three-level neutral point clamped inverter-based grid connection in the future. The cross-regulation capability is examined under a new type of pulse delay control (PDC strategy and later compared with a three-level boost converter (TLBC. Compared to conventional boost converters, the high-voltage three-level buck boost converter (TLBBC with PDC exhibits a wide controllability range and cross regulation capability. These enhanced features are extremely important for better regulating variable output renewable energy sources such as solar, wind, wave, marine current, etc. The simulation and experimental results are provided to validate the claim.

  16. A current-mode DC—DC buck converter with adaptive zero compensation

    International Nuclear Information System (INIS)

    Yang Ling; Dai Guoding; Xu Chongwei; Liu Yuezhi

    2013-01-01

    To achieve fast transient response for a DC—DC buck converter, an adaptive zero compensation circuit is presented. The compensation resistance is dynamically adjusted according to the different output load conditions, and achieves an adequate system phase margin under the different conditions. An improved capacitor multiplier circuit is adopted to realize the minimized compensation capacitance size. In addition, analysis of the small-signal model shows the correctness of the mechanism of the proposed adaptive zero compensation technique. A current-mode DC—DC buck converter with the proposed structure has been implemented in a 0.35 μm CMOS process, and the die size is only 800 × 1040 μm 2 . The experimental results show that the transient undershoot/overshoot voltage and the recovery times do not exceed 40 mV and 30 μs for a load current variation from 100 mA to 1 A. (semiconductor integrated circuits)

  17. Dynamic Sliding Mode Evolution PWM Controller for a Novel High-Gain Interleaved DC-DC Converter in PV System

    Directory of Open Access Journals (Sweden)

    Taizhou Bei

    2014-01-01

    Full Text Available Considering the disadvantages of the traditional high-gain DC-DC converter such as big size, high voltage stress of switches, and large input current ripple, a novel high-gain interleaved boost converter with coupled-inductor and switched-capacitor was proposed correspondingly and the operation principle together with the steady-state analysis of this converter was also described. Besides, a new control approach-dynamic sliding mode evolution PWM controller (DSME PWM for the novel topological converter based on both dynamic evolution and sliding mode control was also presented. From the simulation results and experimental validation the proposed converter can fulfill high-gain boost, low ripple of both the input current and the output voltage. Furthermore, MPPT technique can be also achieved in a short time by simulation. The efficiency and stability of the converter proposed in this paper can be improved.

  18. A ZVS PWM control strategy with balanced capacitor current for half-bridge three-level DC/DC converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    The capacitor current would be imbalanced under the conventional control strategy in the half-bridge three-level (HBTL) DC/DC converter due to the effect of the output inductance of the power supply and the input line inductance, which would affect the converter's reliability. This paper proposes...... a pulse-wide modulation (PWM) strategy composed of two operation modes for the HBTL DC/DC converter, which can realize the zero-voltage switching (ZVS) for the efficiency improvement. In addition, a capacitor current balancing control is proposed by alternating the two operation modes of the proposed ZVS...... PWM strategy, which can eliminate the current imbalance among the two input capacitors. Therefore, the proposed control strategy can improve the converter's performance and reliability in: 1) reducing the switching losses and noises of the power switches; 2) balancing the thermal stresses...

  19. Dynamics and stabilization of peak current-mode controlled buck converter with constant current load

    International Nuclear Information System (INIS)

    Leng Min-Rui; Zhou Guo-Hua; Zhang Kai-Tun; Li Zhen-Hua

    2015-01-01

    The discrete iterative map model of peak current-mode controlled buck converter with constant current load (CCL), containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. (paper)

  20. Hierarchical Velocity Control Based on Differential Flatness for a DC/DC Buck Converter-DC Motor System

    Directory of Open Access Journals (Sweden)

    R. Silva-Ortigoza

    2014-01-01

    Full Text Available This paper presents a hierarchical controller that carries out the angular velocity trajectory tracking task for a DC motor driven by a DC/DC Buck converter. The high level control is related to the DC motor and the low level control is dedicated to the DC/DC Buck converter; both controls are designed via differential flatness. The high level control provides a desired voltage profile for the DC motor to achieve the tracking of a desired angular velocity trajectory. Then, a low level control is designed to ensure that the output voltage of the DC/DC Buck converter tracks the voltage profile imposed by the high level control. In order to experimentally verify the hierarchical controller performance, a DS1104 electronic board from dSPACE and Matlab-Simulink are used. The switched implementation of the hierarchical average controller is accomplished by means of pulse width modulation. Experimental results of the hierarchical controller for the velocity trajectory tracking task show good performance and robustness against the uncertainties associated with different system parameters.

  1. 1 GHz GaAs Buck Converter for High Power Amplifier Modulation Applications

    NARCIS (Netherlands)

    Busking, E.B.; Hek, A.P. de; Vliet, F.E. van

    2012-01-01

    A fully integrated 1 GHz buck converter output stage, including on-chip inductor and DC output filtering has been realized, in a standard high-voltage breakdown GaAs MMIC technology. This is a significant step forward in designing highspeed power control of supply-modulated HPAs (high power

  2. Interleaved Boost-Half-Bridge Dual–Input DC-DC Converter with a PWM plus Phase-Shift Control for Fuel Cell Applications

    DEFF Research Database (Denmark)

    Zhang, Zhe; Andersen, Michael A. E.

    2013-01-01

    This paper presents an isolated dual-input DC-DC converter with a PWM plus phase-shift control for fuel cell hybrid energy systems. The power switches are controlled by phase shifted PWM signals with a variable duty cycle, and thus the two input voltages as well as the output voltage can...

  3. Buck-Boost/Forward Hybrid Converter for PV Energy Conversion Applications

    Directory of Open Access Journals (Sweden)

    Sheng-Yu Tseng

    2014-01-01

    Full Text Available This paper presents a charger and LED lighting (discharger hybrid system with a PV array as its power source for electronic sign indicator applications. The charger adopts buck-boost converter which is operated in constant current mode to charge lead-acid battery and with the perturb and observe method to extract maximum power of PV arrays. Their control algorithms are implemented by microcontroller. Moreover, forward converter with active clamp circuit is operated in voltage regulation condition to drive LED for electronic sign applications. To simplify the circuit structure of the proposed hybrid converter, switches of two converters are integrated with the switch integration technique. With this approach, the proposed hybrid converter has several merits, which are less component counts, lighter weight, smaller size, and higher conversion efficiency. Finally, a prototype of LED driving system under output voltage of 10 V and output power of 20 W has been implemented to verify its feasibility. It is suitable for the electronic sign indicator applications.

  4. Synchronous Buck Converter with Perturb and Observe Maximum Power Point Tracking Implemented on a Low-Cost Arduino-microcontroller

    Directory of Open Access Journals (Sweden)

    Emad Talib Hashim

    2018-02-01

    Full Text Available Maximum power point tracking (MPPT is used in photovoltaic (PV systems to enhance efficiency and maximize the output power of PV module, regardless the variation of temperature, irradiation, and the electrical characteristics of the load. A new MPPT system has been presented in this research, consisting of a synchronous DC-DC step-down Buck converter controlled by an Arduino microcontroller based unit. The MPPT process with Perturb and Observe method is performed with a DC-DC converter circuit to overcome the problem of voltage mismatch between the PV modules and the loads. The proposing system has high efficiency, lower cost and can be easily modified to handle more energy sources. The test results indicate that the use of the proposed MPPT control with the designed synchronous Buck converter increases the PV output power; hence increases the overall solar system efficiency. The synchronous Buck converter test results used in this design showed high converter efficiency up to 95% of the power produced from the solar module, leading to reduce power loss caused by the power transfer process from PV module to the loads.

  5. A Tapped-Inductor Buck-Boost Converter for a Dielectric ElectroActive Polymer Generator

    DEFF Research Database (Denmark)

    Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2014-01-01

    of commercially-available, high-efficient, high-voltage, low-power semiconductor devices. In this paper, a high-efficient bidirectional tapped-inductor buck-boost converter, addressing high step-up and high step-down voltage conversion ratios, is proposed for energy harvesting applications based on DEAP...

  6. Windowed SHE-PWM of Interleaved Four-Quadrant Converters for Resonance Suppression in Traction Power Supply Systems

    DEFF Research Database (Denmark)

    Song, Kejian; Konstantinou, Georgios; Mingli, Wu

    2017-01-01

    AC electric locomotives that use a number of interleaved four-quadrant converters generate high-frequency switching harmonics which may stimulate certain resonances in traction power supply systems (TPSSs). A windowed selective harmonic elimination pulse-width modulation (SHE-PWM) method...

  7. Evaluation of Arm Processor-based Bionic Intelligent Controller for a Buck-boost Converte

    OpenAIRE

    M.V. Mini; L. Padma Suresh

    2015-01-01

    This study focuses on performance-comparison of different tuning methods for a PI controller applied to a buck-boost converter. Comparison between the controllers is made by analysis of design methodology implementation issues and empirically measured performance. Design of PI controller is based on frequency response of the converter. The optimization of PI controller is based on ant colony algorithm. Experimental results show that, tuning the PI controller using ACO algorithm gave better pe...

  8. Application of digital control techniques for satellite medium power DC-DC converters

    Science.gov (United States)

    Skup, Konrad R.; Grudzinski, Pawel; Nowosielski, Witold; Orleanski, Piotr; Wawrzaszek, Roman

    2010-09-01

    The objective of this paper is to present a work concerning a digital control loop system for satellite medium power DC-DC converters that is done in Space Research Centre. The whole control process of a described power converter bases on a high speed digital signal processing. The paper presents a development of a FPGA digital controller for voltage mode stabilization that was implemented using VHDL. The described controllers are a classical digital PID controller and a bang-bang controller. The used converter for testing is a simple model of 5-20 W, 200 kHz buck power converter. A high resolution digital PWM approach is presented. Additionally a simple and effective solution of filtering of an analog-to-digital converter output is presented.

  9. FPGA implementation of optimal and approximate model predictive control for a buck-boost DC-DC converter

    NARCIS (Netherlands)

    Spinu, V.; Oliveri, A.; Lazar, M.; Storace, M.

    2012-01-01

    This paper proposes a method for FPGA implementation of explicit, piecewise af¿ne (PWA) model predictive control (MPC) laws for non-inverting buck-boost DC-DC converters. A novel approach to obtain a PWA model of the power converter is proposed and two explicit MPC laws are derived, i.e., one based

  10. Performance Analysis of Trench Power MOSFETs in High-Frequency Synchronous Buck Converter Applications

    Directory of Open Access Journals (Sweden)

    Yali Xiong

    2008-01-01

    Full Text Available This paper investigates the performance perspectives and theoretical limitations of trench power MOSFETs in synchronous rectifier buck converters operating in the MHz frequency range. Several trench MOSFET technologies are studied using a mixed-mode device/circuit modeling approach. Individual power loss contributions from the control and synchronous MOSFETs, and their dependence on switching frequency between 500 kHz and 5 MHz are discussed in detail. It is observed that the conduction loss contribution decreases from 40% to 4% while the switching loss contribution increases from 60% to 96% as the switching frequency increases from 500 KHz to 5 MHz. Beyond 1 MHz frequency there is no obvious benefit to increase the die size of either SyncFET or CtrlFET. The RDS(ON×QG figure of merit (FOM still correlates well to the overall converter efficiency in the MHz frequency range. The efficiency of the hard switching buck topology is limited to 80% at 2 MHz and 65% at 5 MHz even with the most advanced trench MOSFET technologies.

  11. Maximum Power Point Tracking menggunakan Buck Converter dengan Algoritma P & O untuk Turbin Angin

    Directory of Open Access Journals (Sweden)

    Erik Tridianto

    2016-12-01

    Full Text Available Energi terbarukan adalah salah satu energi alternatif sebagai pengganti bahan bakar untuk pembangkit listrik. Dari berbagai energi terbarukan,yang ada energi angin adalah yang paling mudah dicari. Indonesia merupakan negara kepulauan dengan ratusan pantai dan dengan kecepatan angin yang besar dan berfluktuasi 3-5 m / s. Dan solusi dari masalah angin yang berfluktuasi ini adalah dengan menggunakan kontrol MPPT (Maximum Power Point Tracking dengan lm2596 dc-dc buck converter. Ketika daya yang dihasilkan kurang dari yang diharapkan, maka kontrol MPPT akan menurunkan tegangan untuk mendapatkan daya maksimum. Penelitian ini dilakukan dengan menggunakan lm2596 buck dc-dc converter menggunakan kontrol MPPT dengan tujuan mendapatkan daya maksimum pada kondisi kecepatan angin yang bervariasi, dan jenis MPPT yang digunakan adalah Perturb and Observation (P & O. Untuk membaca daya yang dihasilkan menggunakan Voltage dan Current sensor. Hasil tes menunjukkan bahwa, dengan penambahan kontrol MPPT dapat meningkatkan output daya dari generator sebesar 23%-49%.

  12. Advanced Control Strategy of Back-to-Back PWM Converters in PMSG Wind Power System

    Directory of Open Access Journals (Sweden)

    Tan Luong Van

    2015-01-01

    Full Text Available This paper proposes a control scheme of back-to-back PWM converters for the permanent magnet synchronous generator (PMSG wind turbine system. The DC-link voltage can be controlled at the machine-side converter (MSC, while the grid-side converter (GSC controls the grid active power for a maximum power point tracking (MPPT. At the grid fault condition, the DC-link voltage controller is designed using a feedback linearization (FL theory. For the MPPT, a proportional control loop is added to the torque control to reduce the influence of the inertia moment in the wind turbines, which can improve its dynamic performance. The validity of this control algorithm has been verified by the simulation of the 2-MW PMSG wind turbine system.

  13. Adaptive Control for Buck Power Converter Using Fixed Point Inducting Control and Zero Average Dynamics Strategies

    Science.gov (United States)

    Hoyos Velasco, Fredy Edimer; García, Nicolás Toro; Garcés Gómez, Yeison Alberto

    In this paper, the output voltage of a buck power converter is controlled by means of a quasi-sliding scheme. The Fixed Point Inducting Control (FPIC) technique is used for the control design, based on the Zero Average Dynamics (ZAD) strategy, including load estimation by means of the Least Mean Squares (LMS) method. The control scheme is tested in a Rapid Control Prototyping (RCP) system based on Digital Signal Processing (DSP) for dSPACE platform. The closed loop system shows adequate performance. The experimental and simulation results match. The main contribution of this paper is to introduce the load estimator by means of LMS, to make ZAD and FPIC control feasible in load variation conditions. In addition, comparison results for controlled buck converter with SMC, PID and ZAD-FPIC control techniques are shown.

  14. Power Flow Control of a Dual-Input Interleaved Buck/Boost Converter with Galvanic Isolation for Renewable Energy Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Zhang, Zhe; Knott, Arnold

    2015-01-01

    DC microgrids or nanogrids have attracted increasing research interest in recent years. Therefore, as a critical component, dc-dc converters with multiple inputs are required. In this paper, a dual-input interleaved buck/boost converter is proposed and its corresponding power flow control methods...

  15. Dynamics and stabilization of peak current-mode controlled buck converter with constant current load

    Science.gov (United States)

    Leng, Min-Rui; Zhou, Guo-Hua; Zhang, Kai-Tun; Li, Zhen-Hua

    2015-10-01

    The discrete iterative map model of peak current-mode controlled buck converter with constant current load (CCL), containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. Project supported by the National Natural Science Foundation of China (Grant No. 61371033), the Fok Ying-Tung Education Foundation for Young Teachers in the Higher Education Institutions of China (Grant No. 142027), the Sichuan Provincial Youth Science and Technology Fund, China (Grant Nos. 2014JQ0015 and 2013JQ0033), and the Fundamental Research Funds for the Central Universities, China (Grant No. SWJTU11CX029).

  16. A New parallel Resonant DC-Link Inverter for Soft Switched PWM

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J G; Kim, H S; Cho, G H [Korea Advanced Energy Research Inst., Daeduk-Danji (Korea, Republic of). Korea Nuclear Safety Center

    1993-03-01

    A novel soft switching PWM converter for high frequency AC/DC power conversion is presented by using a new parallel resonant dc-link(PRDCL) and by adopting single phase soft switching(SPSS) technique. The new PRDCL provides variable link pulse position as well as variable link pulse width, which is quite different feature from the other resonant dc-links and thus the PWM capability can be remarkably increased. The SPSS technique is also adopted for further enhancement of PWM capability. Moderate combination of two soft switching operations enables the conventional space vector PWM technique to be used. Due to distinctive advantages including true PWM capability, minimum device voltage stresses(all Vs) and reasonable additional device count(3 devices), the proposed converter can be operated in a wide power range(20-200 KW). Operational principles, analyses and the realization of a space vector PWM of the proposed converter are presented. Simulation results are also shown to verify the operational principle. (author). 15 refs., 14 figs.

  17. Informational model verification of ZVS Buck quasi-resonant DC-DC converter

    Science.gov (United States)

    Vakovsky, Dimiter; Hinov, Nikolay

    2016-12-01

    The aim of the paper is to create a polymorphic informational model of a ZVS Buck quasi-resonant DC-DC converter for the modeling purposes of the object. For the creation of the model is applied flexible open standards for setting, storing, publishing and exchange of data in distributed information environment. The created model is useful for creation of many and different by type variants with different configuration of the composing elements and different inner model of the examined object.

  18. A single-phase PWM controlled AC to DC converter based on control of unity displacement power factor

    OpenAIRE

    Funabiki, Shigeyuki

    1990-01-01

    A modified pulse-width modulation (PWM) technique that improves the displacement power factor and the input power factor of a single-phase AC to DC converter is discussed. The modified converter is shown to have a high input power factor and allows the of DC voltage from zero to more than the maximum value of the source voltage. The displacement power factor is unity, and the input power factor is almost unity in the wide range of current command

  19. A Dual-Bridge LLC Resonant Converter with Fixed-Frequency PWM Control for Wide Input Applications

    DEFF Research Database (Denmark)

    Xiaofeng, Sun; Li, Xiaohua; Shen, Yanfeng

    2017-01-01

    This paper proposes a dual-bridge (DB) LLC resonant converter for wide input applications. The topology is an integration of a half-bridge (HB) LLC circuit and a full-bridge (FB) LLC circuit. The fixed-frequency PWM control is employed and a range of twice the minimum input voltage can be covered....... Compared with the traditional pulse frequency modulation (PFM) controlled HB/FB LLC resonant converter, the voltage gain range is independent of the quality factor and the magnetizing inductor has little influence on the voltage gain, which can simplify the parameter selection process and benefit...

  20. Zero-Voltage Switching PWM Strategy Based Capacitor Current-Balancing Control for Half-Bridge Three-Level DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2018-01-01

    The current imbalance among the two input capacitors is one of the important issues of the half-bridge threelevel (HBTL) DC/DC converter, which would affect system performance and reliability. In this paper, a zero-voltage switching (ZVS) pulse-wide modulation (PWM) strategy including two operation...

  1. Buck-Boost DC-DC Converter Control by Using the Extracted Model from Signal Flow Graph Method

    OpenAIRE

    Mohammadian, Leila; Babaei, Ebrahim; Bannae Sharifian, Mohammad Bagher

    2015-01-01

    In this paper, the signal flow graph technique and Mason gain formula are applied for extracting the model and transfer functions from control to output and from input to output of a buck-boost converter. In order to investigate a controller necessity for the converter of assumed parameters, the frequency and time domain analysis are done and the open loop system characteristics are verified and the needed closed loop controlled system specifications are determined. Finally designing a contro...

  2. Synchronized Pulsed dc - dc Converter as Maximum Power Position Tracker with Wide Load and Insolation Variation for Stand Alone PV System

    International Nuclear Information System (INIS)

    Hardik, P. Desai; Ranjan Maheshwari

    2011-01-01

    This paper investigates the interest focused on employing parallel connected dc-dc converter with high tracking effectiveness under wide variation in environmental conditions (Insolation) and wide load variation. dc-dc converter is an essential part of the stand alone PV system. Paper also presents an approach on how duty cycle for maximum power position (MPP) is adjusted by taking care of varying load conditions and without iterative steps. Synchronized PWM pulses are employed for the converter. High tracking efficiency is achieved with continuous input and inductor current. In this approach, the converter can he utilized in buck as well in boost mode. The PV system simulation was verified and experimental results were in agreement to the presented scheme. (authors)

  3. A tapped-inductor buck-boost converter for a multi-DEAP generator energy harvesting system

    DEFF Research Database (Denmark)

    Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2014-01-01

    the effective operational range of the power electronic converter. In this paper, a bidirectional tapped-inductor buck-boost converter is proposed, addressing high-efficient high step-up and high step-down voltage conversion ratios, for energy harvesting applications based on DEAP generators. The effective...... operational range of the converter is extended, by replacing its high-side switch with a string of three serialized MOSFETs, to accommodate the need for high-efficient high-voltage operation. Experiments conducted on a single DEAP generator - part of a quadruple DEAP generator energy harvesting system...... with all elements installed sequentially in the same circular disk with a 90 phase shift - validate the applicability of the proposed converter, demonstrating energy harvesting of 0.26 J, at 0.5 Hz and 60 % delta-strain; characterized by an energy density of 1.25 J per kg of active material....

  4. Analysis, control and design of a non-inverting buck-boost converter: A bump-less two-level T-S fuzzy PI control.

    Science.gov (United States)

    Almasi, Omid Naghash; Fereshtehpoor, Vahid; Khooban, Mohammad Hassan; Blaabjerg, Frede

    2017-03-01

    In this paper, a new modified fuzzy Two-Level Control Scheme (TLCS) is proposed to control a non-inverting buck-boost converter. Each level of fuzzy TLCS consists of a tuned fuzzy PI controller. In addition, a Takagi-Sugeno-Kang (TSK) fuzzy switch proposed to transfer the fuzzy PI controllers to each other in the control system. The major difficulty in designing fuzzy TLCS which degrades its performance is emerging unwanted drastic oscillations in the converter output voltage during replacing the controllers. Thereby, the fuzzy PI controllers in each level of TLCS structure are modified to eliminate these oscillations and improve the system performance. Some simulations and digital signal processor based experiments are conducted on a non-inverting buck-boost converter to support the effectiveness of the proposed TLCS in controlling the converter output voltage. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  5. EMC Increasing of PWM Rectifier in Comparison with Classical Rectifier

    Directory of Open Access Journals (Sweden)

    R. Dolecek

    2008-12-01

    Full Text Available Pulse width modulated rectifier is a very popular topic nowadays. The modern industrial production demands continuous and lossless conversion of electrical energy parameters. This need leads to wide spread of power semiconductor converters. The rapid development in power electronics and microprocessor technology enables to apply sophisticated control methods that eliminate negative side effects of the power converters on the supply network. The phase controlled thyristor rectifiers overload the supply network with higher harmonics and reactive power consumption. That is why the PWM rectifier is being examined. In comparison with the phase controlled rectifier it can be controlled to consume nearly sinusoidal current with power factor equal to unity. Another advantage is its capability of energy recuperation. The PWM rectifier can assert itself for its good behavior in many applications, for example as an input rectifier in indirect frequency converter, or in traction. Traction vehicles equipped with PWM rectifier do not consume reactive power, do not load the supply network with higher harmonics, and the recuperation is possible. The paper deals with the PWM rectifier functional model realization and examination. Electromagnetic compatibility of PWM rectifier and classical phase controlled rectifier is compared on the basis of the input current harmonic analysis.

  6. Two-Stage Control Design of a Buck Converter/DC Motor System without Velocity Measurements via a Σ−Δ-Modulator

    Directory of Open Access Journals (Sweden)

    R. Silva-Ortigoza

    2013-01-01

    differential flatness property of the DC-motor model is exploited in order to propose a first-stage controller, which is designed to achieve the desired angular velocity trajectory. This controller provides the voltage profiles that must be tracked by the Buck converter. Then, a second-stage controller is meant to assure the aforementioned. This controller is based on flatness property of the Buck power converter model, which provides the input voltage to the DC motor. Due to the fact that the two-stage controller proposed uses the average model of the system, as a practical and effective implementation of this controller, a Σ − Δ-modulator is employed. Finally, in order to verify the control performance of this approach, numerical simulations are included.

  7. Digitally Controlled Point of Load Converter with Very Fast Transient Response

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Andersen, Michael Andreas E.

    2007-01-01

    voltage mode control and very fast transient response. The DiSOM modulator is combined with a digital PID compensator algorithm is implemented in a hybrid CPLD/FPGA and is used to control a synchronous Buck converter, which is used in typical Point of Load applications. The computational time is only......This paper presents a new Digital Self-Oscillating Modulator (DiSOM) that allows the duty cycle to be changed instantly. The DiSOM modulator is shown to have variable switching that is a function of the duty cycle. Compared to a more traditional digital PWM modulator based on a counter...... and comparator the DiSOM modulator allows the sampling frequency of the output voltage control loop to be higher than the switching frequency of the power converter, typically a DC/DC converter. The features of the DiSOM modulator makes it possible to design a digitally controlled DC/DC converter with linear...

  8. Deadbeat control of power leveling unit with bidirectional buck/boost DC/DC converter

    OpenAIRE

    Hamasaki, Shin-ichi; Mukai, Ryosuke; Yano, Yoshihiro; Tsuji, Mineo

    2014-01-01

    As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Electric double-layer capacitor (EDLC) is able to absorb change of power, and it is...

  9. Analysis and Control of Buck-Boost Converter with the Same Input Polarity Based on Novel Energy Factor Evaluation

    Directory of Open Access Journals (Sweden)

    Mahmoud Shaker Nasr

    2017-03-01

    Full Text Available This paper presents firstly a buck-boost circuit with the advantage that its output voltage polarity is the same as the input polarity. The circuit operation is presented and analyzed in different modes of operation. The well known parameters used in evaluation of DC/DC converters like Total Harmonic Distortion THD, Power Factor PF, and Ripple Factor RF have no meaning in DC/DC converters, so it is to introduce efficient concepts to permit a fair evaluation of the converter. This paper present other parameters that can be used to study the characteristics of the converter and gives a real and logic means of its operation. These main parameters are: pumping energy PE, storage energy SE, energy factor EF, and energy losses EL. In addition, the converter efficiency is not considered as 100 % as taken in most analyzing studies. The positive DC/DC buck-boost converter is evaluated according to the new concepts and the system model is deduced for different cases of operation taking into account the resistance of the circuit inductor. The circuit is implemented practically and the presented obtained results show the correct operation under different modes of operation. In addition the control design of the converter is built such that a PI controller with windup is considered. In order to test the effectiveness of the designed control algorithm, the system were exposed to different voltage reference values and the obtained results demonstrate that the system responses for all cases are very acceptable according to the criteria of the control system theory.

  10. Analysis of a PWM Resonant Buck Chopper for Use as a Ship Service Converter Module

    National Research Council Canada - National Science Library

    Ciezki, John

    1999-01-01

    .... This study provides a background analysis into resonant converters which utilize zero-voltage-switching and zero-current-switching techniques to mitigate the aforementioned concerns and facilitate...

  11. Sliding Mode Control of a Bidirectional Buck/Boost DC-DC Converter with Constant Switching Frequency

    Directory of Open Access Journals (Sweden)

    A. Safari

    2018-03-01

    Full Text Available In this paper, sliding mode control (SMC for a bidirectional buck/boost DC-DC converter (BDC with constant frequency in continuous conduction mode (CCM is discussed. Since the converter is a high-order converter, the reduced-order sliding manifold is exploited. Because of right-half-plan zero (RHPZ in the converter’s duty ratio to output voltage transfer function, sliding mode current controller is used. This controller benefits from various advantages such as fast dynamic response, robustness, stable and small variation of the settling time over a wide range of operation conditions. Because the converter operates in both step-down and step-up modes, two sliding manifold is derived for each mode. The existence and stability conditions are analyzed for both SMC in step-down and step-up modes. Finally, Simulation results are also provided to justify the feasibility of the controller using MATLAB/Simulink.

  12. Single Phase Transformer-less Buck-Boost Inverter with Zero Leakage Current for PV Systems

    DEFF Research Database (Denmark)

    Mostaan, Ali; Abdelhakim, Ahmed; N. Soltani, Mohsen

    2017-01-01

    In this paper, a novel single-stage single-phase transformer-less buck-boost inverter is proposed, in which a reduced number of passive components is used. The proposed inverter combines the conventional buck, boost, and buck-boost converters in one converter in order to obtain a sinusoidal output...

  13. A Harmonic Resonance Suppression Strategy for a High-Speed Railway Traction Power Supply System with a SHE-PWM Four-Quadrant Converter Based on Active-Set Secondary Optimization

    Directory of Open Access Journals (Sweden)

    Runze Zhang

    2017-10-01

    Full Text Available Pulse width modulation (PWM technology is widely used in traction converters for high-speed railways. The harmonic distribution caused by PWM is quite extensive, and increases the possibility of grid–train coupling resonance in the traction power supply system (TPSS. This paper first analyzes the mechanism of resonance, when the characteristic harmonic frequency of a four-quadrant converter (4QC current that injects into the traction grid matches the resonant frequency of the traction grid, which may result in resonance in the system. To suppress resonance, this paper adopts specific harmonic elimination–pulse width modulation (SHE-PWM technology combined with a transient direct current control strategy to eliminate the harmonics in the resonant frequency, which may suppress the grid–train coupling resonance. Due to the fact that the SHE-PWM process with multiple switching angles contains complex transcendental equations, the initial value is difficult to provide, and is difficult to solve using ordinary iterative algorithms. In this paper, an active-set secondary optimization method is used to solve the equation. The algorithm has the benefits of low dependence on initial values, fast convergence and high solution accuracy. Finally, the feasibility of the resonant suppression algorithm is verified by means of Matlab simulation.

  14. Harmonic Analyzing of the Double PWM Converter in DFIG Based on Mathematical Model

    Directory of Open Access Journals (Sweden)

    Jing Liu

    2017-12-01

    Full Text Available Harmonic pollution of double fed induction generators (DFIGs has become a vital concern for its undesirable effects on power quality issues of wind generation systems and grid-connected system, and the double pulse width modulation (PWMconverter is one of the main harmonic sources in DFIGs. Thus the harmonic analysis of the converter in DFIGs is a necessary step to evaluate their harmonic pollution of DFIGs. This paper proposes a detailed harmonic modeling method to discuss the main harmonic components in a converter. In general the harmonic modeling could be divided into the low-order harmonic part (up to 30th order and the high-order harmonic part (greater than order 30 parts in general. The low-order harmonics are produced by the circuit topology and control algorithm, and the harmonic component will be different if the control strategy changes. The high-order harmonics are produced by the modulation of the switching function to the dc variable. In this paper, the low-order harmonic modeling is established according to the directions of power flow under the vector control (VC, and the high-order harmonic modeling is established by the switching function of space vector PWM and dc currents. Meanwhile, the simulations of harmonic a components in a converter are accomplished in a real time digital simulation system. The results indicate that the proposed modeling could effectively show the harmonics distribution of the converter in DFIGs.

  15. Application of Minimum-time Optimal Control System in Buck-Boost Bi-linear Converters

    Directory of Open Access Journals (Sweden)

    S. M. M. Shariatmadar

    2017-08-01

    Full Text Available In this study, the theory of minimum-time optimal control system in buck-boost bi-linear converters is described, so that output voltage regulation is carried out within minimum time. For this purpose, the Pontryagin's Minimum Principle is applied to find optimal switching level applying minimum-time optimal control rules. The results revealed that by utilizing an optimal switching level instead of classical switching patterns, output voltage regulation will be carried out within minimum time. However, transient energy index of increased overvoltage significantly reduces in order to attain minimum time optimal control in reduced output load. The laboratory results were used in order to verify numerical simulations.

  16. A Comparative Study of Voltage, Peak Current and Dual Current Mode Control Methods for Noninverting Buck-Boost Converter

    Directory of Open Access Journals (Sweden)

    M. Č. Bošković

    2016-06-01

    Full Text Available This paper presents a comparison of voltage mode control (VMC and two current mode control (CMC methods of noninverting buck-boost converter. The converter control-to-output transfer function, line-to-output transfer function and the output impedance are obtained for all methods by averaging converter equations over one switching period and applying small-signal linearization. The obtained results are required for the design procedure of feedback compensator to keep a system stable and robust. A comparative study of VMC, peak current mode control (PCMC and dual-current mode control (DCMC is performed. Performance evaluation of the closed-loop system with obtained compensator between these methods is performed via numerical simulations.

  17. A fast novel soft-start circuit for peak current-mode DC—DC buck converters

    International Nuclear Information System (INIS)

    Li Jie; Yang Miao; Sun Weifeng; Lu Xiaoxia; Xu Shen; Lu Shengli

    2013-01-01

    A fully integrated soft-start circuit for DC—DC buck converters is presented. The proposed high speed soft-start circuit is made of two sections: an overshoot suppression circuit and an inrush current suppression circuit. The overshoot suppression circuit is presented to control the input of the error amplifier to make output voltage limit increase in steps without using an external capacitor. A variable clock signal is adopted in the inrush current suppression circuit to increase the duty cycle of the system and suppress the inrush current. The DC—DC converter with the proposed soft-start circuit has been fabricated with a standard 0.13 μm CMOS process. Experimental results show that the proposed high speed soft-start circuit has achieved less than 50 μs start-up time. The inductor current and the output voltage increase smoothly over the whole load range. (semiconductor integrated circuits)

  18. Closed-loop analysis and control of a non-inverting buck-boost converter

    Science.gov (United States)

    Chen, Zengshi; Hu, Jiangang; Gao, Wenzhong

    2010-11-01

    In this article, a cascade controller is designed and analysed for a non-inverting buck-boost converter. The fast inner current loop uses sliding mode control. The slow outer voltage loop uses the proportional-integral (PI) control. Stability analysis and selection of PI gains are based on the nonlinear closed-loop error dynamics incorporating both the inner and outer loop controllers. The closed-loop system is proven to have a nonminimum phase structure. The voltage transient due to step changes of input voltage or resistance is predictable. The operating range of the reference voltage is discussed. The controller is validated by a simulation circuit. The simulation results show that the reference output voltage is well-tracked under system uncertainties or disturbances, confirming the validity of the proposed controller.

  19. Sensorless load torque estimation and passivity based control of buck converter fed DC motor.

    Science.gov (United States)

    Kumar, S Ganesh; Thilagar, S Hosimin

    2015-01-01

    Passivity based control of DC motor in sensorless configuration is proposed in this paper. Exact tracking error dynamics passive output feedback control is used for stabilizing the speed of Buck converter fed DC motor under various load torques such as constant type, fan type, propeller type, and unknown load torques. Under load conditions, sensorless online algebraic approach is proposed, and it is compared with sensorless reduced order observer approach. The former produces better response in estimating the load torque. Sensitivity analysis is also performed to select the appropriate control variables. Simulation and experimental results fully confirm the superiority of the proposed approach suggested in this paper.

  20. Solid state light source driver establishing buck or boost operation

    Science.gov (United States)

    Palmer, Fred

    2017-08-29

    A solid state light source driver circuit that operates in either a buck convertor or a boost convertor configuration is provided. The driver circuit includes a controller, a boost switch circuit and a buck switch circuit, each coupled to the controller, and a feedback circuit, coupled to the light source. The feedback circuit provides feedback to the controller, representing a DC output of the driver circuit. The controller controls the boost switch circuit and the buck switch circuit in response to the feedback signal, to regulate current to the light source. The controller places the driver circuit in its boost converter configuration when the DC output is less than a rectified AC voltage coupled to the driver circuit at an input node. The controller places the driver circuit in its buck converter configuration when the DC output is greater than the rectified AC voltage at the input node.

  1. Pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2008-01-01

    This book studies switch-mode power supplies (SMPS) in great detail. This type of converter changes an unregulated DC voltage into a high-frequency pulse-width modulated (PWM) voltage controlled by varying the duty cycle, then changes the PWM AC voltage to a regulated DC voltage at a high efficiency by rectification and filtering. Used to supply electronic circuits, this converter saves energy and space in the overall system. With concept-orientated explanations, this book offers state-of-the-art SMPS technology and promotes an understanding of the principle operations of PWM converters,

  2. Design and Experimentation of a Control System Implemented on Raspberry Pi 3 Board for Photovoltaic Systems Using SEPIC Converter

    Directory of Open Access Journals (Sweden)

    Mohamed Boutouba

    2017-12-01

    Full Text Available In this paper, a voltage regulation system is proposed for photovoltaic energy sources (PV, using Single-Ended Primary Inductance Converter as a DC-DC converter to feed loads working with specific input voltage. The choose of SEPIC converter is due to the output voltage ripple of developed-type converters are usually small and can be lower than 2%, also it considered as a buck and boost converter and thereafter loads with lower or higher voltage could be powered. Matlab Simulink is used as environment to develop control strategies to guaranties a stable voltage at the loads terminals. Two algorithms are used to fulfill this role: A Conventional PID and PI-Fuzzy logic controller to generate the PWM signal for the SEPIC converter. Hence, to validate the work some real-time simulations are treated by implemented the control strategies on a low-cost control board: The Raspberry Pi 3 in order to manage the operation of system and collecting the simulation data. Also, and for verification purposes, several simulations were treated to verify the good behavior of the proposed system.

  3. Bifurcation and chaos in high-frequency peak current mode Buck converter

    Science.gov (United States)

    Chang-Yuan, Chang; Xin, Zhao; Fan, Yang; Cheng-En, Wu

    2016-07-01

    Bifurcation and chaos in high-frequency peak current mode Buck converter working in continuous conduction mode (CCM) are studied in this paper. First of all, the two-dimensional discrete mapping model is established. Next, reference current at the period-doubling point and the border of inductor current are derived. Then, the bifurcation diagrams are drawn with the aid of MATLAB. Meanwhile, circuit simulations are executed with PSIM, and time domain waveforms as well as phase portraits in i L-v C plane are plotted with MATLAB on the basis of simulation data. After that, we construct the Jacobian matrix and analyze the stability of the system based on the roots of characteristic equations. Finally, the validity of theoretical analysis has been verified by circuit testing. The simulation and experimental results show that, with the increase of reference current I ref, the corresponding switching frequency f is approaching to low-frequency stage continuously when the period-doubling bifurcation happens, leading to the converter tending to be unstable. With the increase of f, the corresponding I ref decreases when the period-doubling bifurcation occurs, indicating the stable working range of the system becomes smaller. Project supported by the National Natural Science Foundation of China (Grant No. 61376029), the Fundamental Research Funds for the Central Universities, China, and the College Graduate Research and Innovation Program of Jiangsu Province, China (Grant No. SJLX15_0092).

  4. Transistorized PWM inverter-induction motor drive system

    Science.gov (United States)

    Peak, S. C.; Plunkett, A. B.

    1982-01-01

    This paper describes the development of a transistorized PWM inverter-induction motor traction drive system. A vehicle performance analysis was performed to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of inverter and motor specifications. The inverter was a transistorized three-phase bridge using General Electric power Darlington transistors. The description of the design and development of this inverter is the principal object of this paper. The high-speed induction motor is a design which is optimized for use with an inverter power source. The primary feedback control is a torque angle control with voltage and torque outer loop controls. A current-controlled PWM technique is used to control the motor voltage. The drive has a constant torque output with PWM operation to base motor speed and a constant horsepower output with square wave operation to maximum speed. The drive system was dynamometer tested and the results are presented.

  5. Three new DC-to-DC Single-Switch Converters

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2017-06-01

    Full Text Available This paper presents a new family of three previously unidentified dc-to-dc converters, buck, boost, and buck-boost voltage-transfer-function topologies, which offer advantageous transformer coupling features and low capacitor dc voltage stressing. The three single-switch, single-diode, converters offer the same features as basic dc-to-dc converters, such as the buck function with continuous output current and the boost function with continuous input current. Converter time-domain simulations and experimental results (including transformer coupling support and extol the dc-to-dc converter concepts and analysis presented.

  6. A high-efficiency, low-noise power solution for a dual-channel GNSS RF receiver

    International Nuclear Information System (INIS)

    Shi Jian; Mo Taishan; Gan Yebing; Ma Chengyan; Ye Tianchun; Le Jianlian

    2012-01-01

    A high-efficiency low-noise power solution for a dual-channel GNSS RF receiver is presented. The power solution involves a DC—DC buck converter and a followed low-dropout regulator (LDO). The pulse-width-modulation (PWM) control method is adopted for better noise performance. An improved low-power high-frequency PWM control circuit is proposed, which halves the average quiescent current of the buck converter to 80 μA by periodically shutting down the OTA. The size of the output stage has also been optimized to achieve high efficiency under a light load condition. In addition, a novel soft-start circuit based on a current limiter has been implemented to avoid inrush current. Fabricated with commercial 180-nm CMOS technology, the DC—DC converter achieves a peak efficiency of 93.1% under a 2 MHz working frequency. The whole receiver consumes only 20.2 mA from a 3.3 V power supply and has a noise figure of 2.5 dB. (semiconductor integrated circuits)

  7. Integrated power electronic converters and digital control

    CERN Document Server

    Emadi, Ali; Nie, Zhong

    2009-01-01

    Non-isolated DC-DC ConvertersBuck ConverterBoost ConverterBuck-Boost ConverterIsolated DC-DC ConvertersFlyback ConverterForward ConverterPush-Pull ConverterFull-Bridge ConverterHalf-Bridge ConverterPower Factor CorrectionConcept of PFCGeneral Classification of PFC CircuitsHigh Switching Frequency Topologies for PFCApplication of PFC in Advanced Motor DrivesIntegrated Switched-Mode Power ConvertersSwitched-Mode Power SuppliesThe Concept of Integrated ConverterDefinition of Integrated Switched-Mode Power Supplies (ISMPS)Boost-Type Integrated TopologiesGeneral Structure of Boost-Type Integrated T

  8. Three-phase Resonant DC-link Converter

    DEFF Research Database (Denmark)

    Munk-Nielsen, Stig

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source...... Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this procedure increased dv/dt and the size of the input/output filters of the PWM-SVI must be increased...

  9. A New Application of the Multi-Resonant Zero-Current Switching Buck Converter: Analysis and Simulation in a PMSG Based WECS

    Directory of Open Access Journals (Sweden)

    Tiara Freitas

    2015-09-01

    Full Text Available A new application of the three-phase buck-resonant converter is presented in this paper. It is shown that the analyzed converter is suitable to operate as the rectifier stage in low power wind energy conversion systems (WECS based on permanent magnet synchronous generators (PMSG with variable wind speed. As main features, it presents a single controlled switch, simple implementation and control, and operates with a high power factor and low harmonic distortion over all wind speed ranges. The converter topology, its design equations and its operation are presented, as well as the simulation results of the PMSG based conversion system. From the analysis carried out in the paper it is concluded that the converter is indicated to be employed in distributed generation and hybrid systems where wind generation is associated with other sources.

  10. Simple-topology switched-mode DC-DC converters : dynamics and control

    CERN Document Server

    Wertelaers, P

    2018-01-01

    After a rehearsal of the functioning mode and characteristics of the buck-boost and buck converters, we attempt to formalize a lower-frequency description of the converter, by smoothing the waveforms containing switching ripple. This framework enables the construction of a linear time-invariant computational model, to which voltage-regulating actions can then be added. Emphasis is on the buck converter.

  11. A new power supply regulated PWM-ZCS supplied in current: analysis, project and experiments; Uma nova fonte chaveada PWM-ZCS alimentada em corrente: analise, projeto e experimentacao

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Peter Mantovanelli

    1993-10-01

    This work introduces a new power supply by PWM, operating at constant frequency, with soft communication. The new topology uses only two active switches and absorbs the transformer leakage inductance. Besides, the soft communication takes place with no conduction loss penalty, in comparison with conventional hard switch PWM converters. Principle of operation, analysis, design and experimentation results taken from laboratory prototype rated at 400 W/48 v, 40 Khz, using IGBT are presented. (author) 10 refs., 71 figs.

  12. Maximum Power Point Tracking (MPPT Pada Sistem Pembangkit Listrik Tenaga Angin Menggunakan Buck-Boost Converter

    Directory of Open Access Journals (Sweden)

    Muhamad Otong

    2017-05-01

    Full Text Available In this paper, the implementation of the Maximum Power Point Tracking (MPPT technique is developed using buck-boost converter. Perturb and observe (P&O MPPT algorithm is used to searching maximum power from the wind power plant for charging of the battery. The model used in this study is the Variable Speed Wind Turbine (VSWT with a Permanent Magnet Synchronous Generator (PMSG. Analysis, design, and modeling of wind energy conversion system has done using MATLAB/simulink. The simulation results show that the proposed MPPT produce a higher output power than the system without MPPT. The average efficiency that can be achieved by the proposed system to transfer the maximum power into battery is 90.56%.

  13. Simulation analysis of cascade controller for DC-DC bank converter

    International Nuclear Information System (INIS)

    Mahar, M.A.; Abro, M.R.; Larik, A.S.

    2009-01-01

    Power electronic converters are periodic variable structure systems due to their switched operation. During the last few decades several new dc-dc converter topologies have emerged. Buck converter being simple in topology, has recently drawn attraction of many researchers. Basically, a buck converter is highly underdamped system. In order to overcome the developed oscillations in output of this converter, various control techniques have been proposed. However, these techniques are fraught with many drawbacks. This paper focus on a cascade controller based buck topology. Steady state analysis is given in this paper which shows output voltage and inductor current in detail. Dynamic analysis for line and load variation is also presented. The buck topology is implemented and simulated in MATLAB/Simulink. The simulated results are presented. (author)

  14. Synchronous Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede; Bose, Bimal K.

    2002-01-01

    A novel method of direct synchronous pulsewidth modulation (PWM) is applied for control of modular multilevel converters consisting from three standard triphase inverter modules along with an 0.33 p.u. output transformer. The proposed method provides synchronisation of the voltage waveforms...... for each module and the composed voltage at the output of the converter. Multilevel output voltage of the converter has quarter-wave symmetry during the whole range including the zone of overmodulation. Both continuous and discontinuous versions of synchronous PWM, based on vector approach...

  15. A moving pole-placement compensation design method to increase the bandwidth of RC-damper-based dual “Buck-Boost” AC/DC converter

    DEFF Research Database (Denmark)

    Wu, Weimin; Qin, Weibo; Wang, Houqin

    2017-01-01

    the “Buck” mode, the control-to-grid current transfer function of this dual “Buck-Boost” AC/DC converter has a movable zero, which is related to the input power and the output DC voltage. When the input power increases, the movable zero will slide to the lower frequency range. And then, the gain between...... the cut-off frequency point and the resonant frequency of LCL filter will swell up, resulting in reduced amplitude margin and suppressed bandwidth of system. Based on the theoretical analysis, a new dynamic pole placement compensation control design method is proposed for this dual AC/DC converter...

  16. Led spectral and power characteristics under hybrid PWM/AM dimming strategy

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2010-01-01

    In order to dim LEDs the pulse width modulation (PWM) or amplitude modulation (AM) dimming scheme is typically used. Previous studies show that these dimming schemes can have opposite effects on diodes peak wavelength shift. An experimental study was conducted to test the behavior of InGaN diodes...... and phosphor-converted white diodes under hybrid PWM/AM modulation. Feed forward control schemes that provide stable peak wavelength position during dimming and the ability to compensate the thermally induced color shifts and the decrease of the luminous flux are investigated....

  17. A nonlinear adaptive backstepping approach applied to a three phase PWM AC-DC converter feeding induction heating

    Science.gov (United States)

    Hadri-Hamida, A.; Allag, A.; Hammoudi, M. Y.; Mimoune, S. M.; Zerouali, S.; Ayad, M. Y.; Becherif, M.; Miliani, E.; Miraoui, A.

    2009-04-01

    This paper presents a new control strategy for a three phase PWM converter, which consists of applying an adaptive nonlinear control. The input-output feedback linearization approach is based on the exact cancellation of the nonlinearity, for this reason, this technique is not efficient, because system parameters can vary. First a nonlinear system modelling is derived with state variables of the input current and the output voltage by using power balance of the input and output, the nonlinear adaptive backstepping control can compensate the nonlinearities in the nominal system and the uncertainties. Simulation results are obtained using Matlab/Simulink. These results show how the adaptive backstepping law updates the system parameters and provide an efficient control design both for tracking and regulation in order to improve the power factor.

  18. Power Electronic Transformer based Three-Phase PWM AC Drives

    Science.gov (United States)

    Basu, Kaushik

    A Transformer is used to provide galvanic isolation and to connect systems at different voltage levels. It is one of the largest and most expensive component in most of the high voltage and high power systems. Its size is inversely proportional to the operating frequency. The central idea behind a power electronic transformer (PET) also known as solid state transformer is to reduce the size of the transformer by increasing the frequency. Power electronic converters are used to change the frequency of operation. Steady reduction in the cost of the semiconductor switches and the advent of advanced magnetic materials with very low loss density and high saturation flux density implies economic viability and feasibility of a design with high power density. Application of PET is in generation of power from renewable energy sources, especially wind and solar. Other important application include grid tied inverters, UPS e.t.c. In this thesis non-resonant, single stage, bi-directional PET is considered. The main objective of this converter is to generate adjustable speed and magnitude pulse width modulated (PWM) ac waveforms from an ac or dc grid with a high frequency ac link. The windings of a high frequency transformer contains leakage inductance. Any switching transition of the power electronic converter connecting the inductive load and the transformer requires commutation of leakage energy. Commutation by passive means results in power loss, decrease in the frequency of operation, distortion in the output voltage waveform, reduction in reliability and power density. In this work a source based partially loss-less commutation of leakage energy has been proposed. This technique also results in partial soft-switching. A series of converters with novel PWM strategies have been proposed to minimize the frequency of leakage inductance commutation. These PETs achieve most of the important features of modern PWM ac drives including 1) Input power factor correction, 2) Common

  19. Bi-directional power control system for voltage converter

    Science.gov (United States)

    Garrigan, Neil Richard; King, Robert Dean; Schwartz, James Edward

    1999-01-01

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

  20. Common mode noise in three-level DC-DC converters

    CSIR Research Space (South Africa)

    Grobler, Inus

    2009-09-01

    Full Text Available that three-level buck DC-DC converters in general generate much lower common mode currents than conventional two-level buck converters. Further, reductions in common mode currents are achieved by using the improved three-level topologies that have been...

  1. Maximum Power Point Tracking for Cascaded PV-Converter Modules Using Two-Stage Particle Swarm Optimization.

    Science.gov (United States)

    Mao, Mingxuan; Duan, Qichang; Zhang, Li; Chen, Hao; Hu, Bei; Duan, Pan

    2017-08-24

    The paper presents a novel two-stage particle swarm optimization (PSO) for the maximum power point tracking (MPPT) control of a PV system consisting of cascaded PV-converter modules, under partial shading conditions (PSCs). In this scheme, the grouping method of the shuffled frog leaping algorithm (SFLA) is incorporated with the basic PSO algorithm, ensuring fast and accurate searching of the global extremum. An adaptive speed factor is also introduced to improve its convergence speed. A PWM algorithm enabling permuted switching of the PV sources is applied. The method enables this PV system to achieve the maximum power generation for any number of PV and converter modules. Simulation studies of the proposed MPPT scheme are performed on a system having two chained PV buck-converter modules and a dc-ac H-bridge connected at its terminals for supplying an AC load. The results show that this type of PV system allows each module to achieve the maximum power generation according its illumination level without affecting the others, and the proposed new control method gives significantly higher power output compared with the conventional P&O and PSO methods.

  2. FPA Tuned Fuzzy Logic Controlled Synchronous Buck Converter for a Wave/SC Energy System

    Directory of Open Access Journals (Sweden)

    SAHIN, E.

    2017-02-01

    Full Text Available This paper presents a flower pollination algorithm (FPA tuned fuzzy logic controlled (FLC synchronous buck converter (SBC for an integrated wave/ supercapacitor (SC hybrid energy system. In order to compensate the irregular wave effects on electrical side of the wave energy converter (WEC, a SC unit charged by solar panels is connected in parallel to the WEC system and a SBC is controlled to provide more reliable and stable voltage to the DC load. In order to test the performance of the designed FLC, a classical proportional-integral-derivative (PID controller is also employed. Both of the controllers are optimized by FPA which is a pretty new optimization algorithm and a well-known optimization algorithm of which particle swarm optimization (PSO to minimize the integral of time weighted absolute error (ITAE performance index. Also, the other error-based objective functions are considered. The entire energy system and controllers are developed in Matlab/Simulink and realized experimentally. Real time applications are done through DS1104 Controller Board. The simulation and experimental results show that FPA tuned fuzzy logic controller provides lower value performance indices than conventional PID controller by reducing output voltage sags and swells of the wave/SC energy system.

  3. Neural network based PWM AC chopper fed induction motor drive

    Directory of Open Access Journals (Sweden)

    Venkatesan Jamuna

    2009-01-01

    Full Text Available In this paper, a new Simulink model for a neural network controlled PWM AC chopper fed single phase induction motor is proposed. Closed loop speed control is achieved using a neural network controller. To maintain a constant fluid flow with a variation in pressure head, drives like fan and pump are operated with closed loop speed control. The need to improve the quality and reliability of the drive circuit has increased because of the growing demand for improving the performance of motor drives. With the increased availability of MOSFET's and IGBT's, PWM converters can be used efficiently in low and medium power applications. From the simulation studies, it is seen that the PWM AC chopper has a better harmonic spectrum and lesser copper loss than the Phase controlled AC chopper. It is observed that the drive system with the proposed model produces better dynamic performance, reduced overshoot and fast transient response. .

  4. An Algebraic Method of Synchronous Pulsewidth Modulation for Converters for Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    This paper describes the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of the output voltage of converters, based on one-stage closed-form strategy of PWM with pure algebraic control dependencies. It is applied to voltage source inverters with a contin......This paper describes the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of the output voltage of converters, based on one-stage closed-form strategy of PWM with pure algebraic control dependencies. It is applied to voltage source inverters...... with a continuous scheme of conventional voltage space vector modulation and with two basic variants of symmetrical discontinuous PWM. Simulations give the behaviour of the proposed method and show the advantage of algebraic synchronous PWM compared with the typical asynchronous, for low indices of the frequency...

  5. Modelling and Control Design of a Dual Buck-Boost AC/DC Converter Used in the DC Nano-Grid

    DEFF Research Database (Denmark)

    Wu, Weimin; Liu, Yuan; Wang, Houqing

    2016-01-01

    Due to widely used DC characterized loads and more distributed power generation sources, the DC Nano-grid becomes more and more popular and seen as an alternative to the AC-grid in future. For the safety considerations, the DC Nano-grid should provide reliable grounding for the residential loads...... like the low voltage AC power system. In this paper, a dual Buck-Boost AC/DC converter for use in the united grounding configuration based DC Nano-grid with three terminal outputs is proposed. It will be much easy to construct an efficient DC Nano-grid based on the existing low AC power system by using...

  6. Triphase Cascaded Converters with Direct Synchronous Pulswidth Modulation

    DEFF Research Database (Denmark)

    Oleschuk, V.; Blaabjerg, Frede; Bose, B. K.

    2002-01-01

    A novel method of direct synchronous pulse-width modulation (PWM) is applied for control of modular multilevel converters consisting from three standard triphase inverter modules along with an 0.33 p.u. output transformer. The proposed method provides synchronisation of the voltage waveforms...... for both each module and the composed voltage at the output of the converter. Multilevel output voltage of the converter has quarter-wave symmetry during the whole range including the zone of overmodulation. Both continuous and discontinuous versions of synchronous PWM, based on a vector approach...

  7. Two-inductor boost and buck converters

    Science.gov (United States)

    White, J. L.; Muldoon, W. J.

    The derivation, analysis and design of a coupled inductor boost converter is presented. Aspects of the qualitative ac behavior of coupled inductor converters are discussed. Considerations for the design of the magnetics for such converters are addressed.

  8. A High Step-Down Interleaved Buck Converter with Active-Clamp Circuits for Wind Turbines

    Directory of Open Access Journals (Sweden)

    Chih-Lung Shen

    2012-12-01

    Full Text Available In this paper, a high step-down interleaved buck coupled-inductor converter (IBCC with active-clamp circuits for wind energy conversion has been studied. In high step-down voltage applications, an IBCC can extend duty ratio and reduce voltage stresses on active switches. In order to reduce switching losses of active switches to improve conversion efficiency, a IBCC with soft-switching techniques is usually required. Compared with passive-clamp circuits, the IBCC with active-clamp circuits have lower switching losses and minimum ringing voltage of the active switches. Thus, the proposed IBCC with active-clamp circuits for wind energy conversion can significantly increase conversion efficiency. Finally, a 240 W prototype of the proposed IBCC with active-clamp circuits was built and implemented. Experimental results have shown that efficiency can reach as high as 91%. The proposed IBCC with active-clamp circuits is presented in high step-down voltage applications to verify the performance and the feasibility for energy conversion of wind turbines.

  9. GENETIC ALGORITHM BASED SOLUTION IN PWM CONVERTER SWITCHING FOR VOLTAGE SOURCE INVERTER FEEDING AN INDUCTION MOTOR DRIVE

    Directory of Open Access Journals (Sweden)

    V. Jegathesan

    2017-11-01

    Full Text Available This paper presents an efficient and reliable Genetic Algorithm based solution for Selective Harmonic Elimination (SHE switching pattern. This method eliminates considerable amount of lower order line voltage harmonics in Pulse Width Modulation (PWM inverter. Determination of pulse pattern for the elimination of some lower order harmonics of a PWM inverter necessitates solving a system of nonlinear transcendental equations. Genetic Algorithm is used to solve nonlinear transcendental equations for PWM-SHE. Many methods are available to eliminate the higher order harmonics and it can be easily removed. But the greatest challenge is to eliminate the lower order harmonics and this is successfully achieved using Genetic Algorithm without using Dual transformer. Simulations using MATLABTM and Powersim with experimental results are carried out to validate the solution. The experimental results show that the harmonics up to 13th were totally eliminated.

  10. Improvement of Shade Resilience in Photovoltaic Modules Using Buck Converters in a Smart Module Architecture

    Directory of Open Access Journals (Sweden)

    S. Zahra Mirbagheri Golroodbari

    2018-01-01

    Full Text Available Partial shading has a nonlinear effect on the performance of photovoltaic (PV modules. Different methods of optimizing energy harvesting under partial shading conditions have been suggested to mitigate this issue. In this paper, a smart PV module architecture is proposed for improvement of shade resilience in a PV module consisting of 60 silicon solar cells, which compensates the current drops caused by partial shading. The architecture consists of groups of series-connected solar cells in parallel to a DC-DC buck converter. The number of cell groups is optimized with respect to cell and converter specifications using a least-squares support vector machine method. A generic model is developed to simulate the behavior of the smart architecture under different shading patterns, using high time resolution irradiance data. In this research the shading patterns are a combination of random and pole shadows. To investigate the shade resilience, results for the smart architecture are compared with an ideal module, and also ordinary series and parallel connected architectures. Although the annual yield for the smart architecture is 79.5% of the yield of an ideal module, we show that the smart architecture outperforms a standard series connected module by 47%, and a parallel architecture by 13.4%.

  11. A Hamiltonian viewpoint in the modeling of switching power converters : A systematic modeling procedure of a large class of switching power converters using the Hamiltonian approach

    NARCIS (Netherlands)

    Escobar, Gerardo; Schaft, Arjan J. van der; Ortega, Romeo

    1999-01-01

    In this paper we show how, using the Hamiltonian formalism, we can systematically derive mathematical models that describe the behaviour of a large class of switching power converters, including the "Boost", "Buck", "Buck-Boost", "Čuk" and "Flyback" converters. We follow the approach earlier

  12. Design and Analysis of Two-Phase Boost DC-DC Converter

    OpenAIRE

    Taufik Taufik; Tadeus Gunawan; Dale Dolan; Makbul Anwari

    2010-01-01

    Multiphasing of dc-dc converters has been known to give technical and economical benefits to low voltage high power buck regulator modules. A major advantage of multiphasing dc-dc converters is the improvement of input and output performances in the buck converter. From this aspect, a potential use would be in renewable energy where power quality plays an important factor. This paper presents the design of a 2-phase 200W boost converter for battery charging application. Analysis of results fr...

  13. Convertidor buck-boost controlado digitalmente con histeresis cero mediante un dsp; Back-Booost Converter digitally controlled by zero hysteresis method, using DSP

    Directory of Open Access Journals (Sweden)

    Fredy Edimer Hoyos Velasco

    2011-02-01

    Full Text Available En este trabajo se estudia el comportamiento de un convertidor electrónico en configuración buck-boost. Elobjetivo del controlador es hacer el rastreo de señales sinusoidales usando un controlador con histéresiscero, es decir que el usuario pueda tener a la salida cualquier señal a un nivel más alto de potencia y conla característica que esta señal deseada es regulada variable en frecuencia, en amplitud y forma de onda.El controlador es rápido pues se comprobó en el laboratorio que ante perturbaciones en la carga y en laseñal de referencia, se comporta adecuadamente. Se implementó el convertidor usando un inversormonofásico en configuración de medio puente y se controla el sistema con un prototipo rápido de control(RCP DS1104 en tiempo real. In this work, we analysed the behaviour of a buck-boost electronic converter. The objective of the zerohysteresis controller is to track user defined sinusoidal signals, usually featuring high power level andvariable frequency, amplitude and wave form. The controller was implemented in the laboratory, whereload and reference signal disturbances were introduced. The controller achieved a fast and adequatebehaviour. The converter was implemented using a half bridge monophasic inverter, and a rapid controlprototyping (RCP DS1104 in real time for the control task.

  14. A novel five-level optimized carrier multilevel PWM quad-inverter six-phase AC drive

    DEFF Research Database (Denmark)

    Sanjeevikumar, P.; Blaabjerg, F.; Wheeler, Pat

    2016-01-01

    A novel single carrier pulse-width modulation (PWM) for a new quad-inverter configuration for multilevel six-phase asymmetrical open-winding ac converter is proposed in this article. Modularity of the circuit consist of four standard two-level voltage source inverters (VSIs) with slight modificat......A novel single carrier pulse-width modulation (PWM) for a new quad-inverter configuration for multilevel six-phase asymmetrical open-winding ac converter is proposed in this article. Modularity of the circuit consist of four standard two-level voltage source inverters (VSIs) with slight...... modifications, i.e. one additional bi-direction switch (MOSFET/IGBT) in each phase and a link to neutral with two capacitors to generate increased output levels. Furthermore, original optimal single carrier zero-shifted five-level modulation (SCZSFM) algorithm is developed for each VSI to behave as equivalent...

  15. Análisis de la estabilidad de un convertidor buck multicelular de dos celdas

    Directory of Open Access Journals (Sweden)

    Julián Pelaéz

    2014-12-01

    Full Text Available En este trabajo se presenta un convertidor multicelular con dos células bajo un modo de modulación (PWM de control de voltaje por ancho de pulso. El convertidor buck multicelular obtenido puede ser utilizado como un circuito electrónico de potencia para aplicaciones de alta tensión; donde los dispositivos semiconductores tienen la capacidad de cambiar solo a niveles de bajo voltaje. El análisis de estabilidad se ha hecho para un control puramente proporcional y más tarde, se ha extendido para un control Proporcional-Integral (PI. Los resultados de la simulación demuestran la validez del análisis.

  16. State-plane analysis of zero-voltage-switching resonant dc/dc power converters

    Science.gov (United States)

    Kazimierczuk, Marian K.; Morse, William D.

    The state-plane analysis technique for the zero-voltage-switching resonant dc/dc power converter family of topologies, namely the buck, boost, buck-boost, and Cuk converters is established. The state plane provides a compression of information that allows the designer to uniquely examine the nonlinear dynamics of resonant converter operation. Utilizing the state plane, resonant converter modes of operation are examined and the switching frequencies are derived for the boundaries between these modes, including the boundary of energy conversion.

  17. Loss Distribution Analysis of Three-Level Active Neutral-Point-Clamped (3L-ANPC) Converter with Different PWM Strategies

    DEFF Research Database (Denmark)

    Zhang, Gang; Yang, Yongheng; Iannuzzo, Francesco

    2016-01-01

    The three-level (3L) Active Neutral-Point-Clamped (ANPC) topology has been introduced to resolve the uneven loss distribution issue in the classical 3L Neutral-Point-Clamped (NPC) topology. This Pulse-Width-Modulation (PWM) strategy is then an important means to fully explore the potential benefits...... are separated in order to improve the loss distribution among the power devices. A comparison between the proposed strategy and other major PWM strategies for the loss distribution is also carried out in this paper. Benchmarking results show that the proposed strategy has effective and superior performance...

  18. Application handbook for a Standardized Control Module (SCM) for DC-DC converters, volume 1

    Science.gov (United States)

    Lee, F. C.; Mahmoud, M. F.; Yu, Y.

    1980-04-01

    The standardized control module (SCM) was developed for application in the buck, boost and buck/boost DC-DC converters. The SCM used multiple feedback loops to provide improved input line and output load regulation, stable feedback control system, good dynamic transient response and adaptive compensation of the control loop for changes in open loop gain and output filter time constraints. The necessary modeling and analysis tools to aid the design engineer in the application of the SCM to DC-DC Converters were developed. The SCM functional block diagram and the different analysis techniques were examined. The average time domain analysis technique was chosen as the basic analytical tool. The power stage transfer functions were developed for the buck, boost and buck/boost converters. The analog signal and digital signal processor transfer functions were developed for the three DC-DC Converter types using the constant on time, constant off time and constant frequency control laws.

  19. Application handbook for a Standardized Control Module (SCM) for DC-DC converters, volume 1

    Science.gov (United States)

    Lee, F. C.; Mahmoud, M. F.; Yu, Y.

    1980-01-01

    The standardized control module (SCM) was developed for application in the buck, boost and buck/boost DC-DC converters. The SCM used multiple feedback loops to provide improved input line and output load regulation, stable feedback control system, good dynamic transient response and adaptive compensation of the control loop for changes in open loop gain and output filter time constraints. The necessary modeling and analysis tools to aid the design engineer in the application of the SCM to DC-DC Converters were developed. The SCM functional block diagram and the different analysis techniques were examined. The average time domain analysis technique was chosen as the basic analytical tool. The power stage transfer functions were developed for the buck, boost and buck/boost converters. The analog signal and digital signal processor transfer functions were developed for the three DC-DC Converter types using the constant on time, constant off time and constant frequency control laws.

  20. A comprehensive study and analysis of second order harmonic ripple in DC microgrid feeding single phase PWM inverter loads

    DEFF Research Database (Denmark)

    Gautam, Aditya R.; Fulwani, Deepak; Guerrero, Josep M.

    2016-01-01

    The paper presents a detailed analysis of second order harmonic ripple in a DC microgrid. A boost converter feeding PWM inverter load is considered and equivalent circuit is proposed. The effect of the size of input capacitor, output capacitor and inductor of boost converter, on this ripple has...

  1. A THREE-PHASE BOOST DC-AC CONVERTER

    African Journals Online (AJOL)

    dc-ac converter (inverter) based on the dc-dc boost converters. ... Sliding mode controllers are designed to perform a robust control for the ... Computer simulations and spectral analysis demon- ... the conventional three-phase buck inverter,.

  2. Laboratory manual for pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2015-01-01

    Designed to complement a range of power electronics study resources, this unique lab manual helps students to gain a deep understanding of the operation, modeling, analysis, design, and performance of pulse-width modulated (PWM) DC-DC power converters.  Exercises focus on three essential areas of power electronics: open-loop power stages; small-signal modeling, design of feedback loops and PWM DC-DC converter control schemes; and semiconductor devices such as silicon, silicon carbide and gallium nitride. Meeting the standards required by industrial employers, the lab manual combines program

  3. A Comparative Study of Analog Voltage-mode Control Methods for Ultra-Fast Tracking Power Supplies

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    This paper presents a theoretical and experimental comparison of the standard PWM/PID voltage-mode control method for single-phase buck converters with two highperformance self-oscillating (a.k.a. sliding mode) control methods. The application considered is ultra-fast tracking power supplies...... (UFTPSs) for RF power amplifiers, where the switching converter needs to track a varying reference voltage precisely and quickly while maintaining low output impedance. The small-signal analyses performed on the different controllers show that the hysteretic-type controller can achieve the highest loop...

  4. Three-phase Resonant DC-link Converter

    OpenAIRE

    Munk-Nielsen, Stig

    1997-01-01

    The purpose of the project is to develop a three-phase resonant converter suitable for standard speed drives. The motivation for working with resonant converters is found in the problem of the standard converter type used today. In standard converter type Pulse Width Modulated-Voltage Source Inverter, PWM-VSI, the switches are subject to high current and voltage stress during switching, which causes losses. The fast switching of modern switches reduces switching losses. Unfortunately this pro...

  5. Electromagnetic phenomena analysis in brushless DC motor with speed control using PWM method

    Science.gov (United States)

    Ciurys, Marek Pawel

    2017-12-01

    Field-circuit model of a brushless DC motor with speed control using PWM method was developed. Waveforms of electrical and mechanical quantities of the designed motor with a high pressure vane pump built in a rotor of the motor were computed. Analysis of electromagnetic phenomena in the system: single phase AC network - converter - BLDC motor was carried out.

  6. dc analysis and design of zero-voltage-switched multi-resonant converters

    Science.gov (United States)

    Tabisz, Wojciech A.; Lee, Fred C.

    Recently introduced multiresonant converters (MRCs) provide zero-voltage switching (ZVS) of both active and passive switches and offer a substantial reduction of transistor voltage stress and an increase of load range, compared to their quasi-resonant converter counterparts. Using the resonant switch concept, a simple, generalized analysis of ZVS MRCs is presented. The conversion ratio and voltage stress characteristics are derived for basic ZVS MRCs, including buck, boost, and buck/boost converters. Based on the analysis, a design procedure that optimizes the selection of resonant elements for maximum conversion efficiency is proposed.

  7. A Sepic Type Switched Mode Power Supply System For Battery Charging In An Electric Tricycle Auto-Rickshaw

    Directory of Open Access Journals (Sweden)

    Kureve

    2017-08-01

    Full Text Available This paper analyzes the plug-in electric tricycle Auto rickshaw battery charging system using a non-isolated DC-DC SEPIC converter which operates as a switched mode power supply SMPS. The control of dc voltage output is by varying the gating pulses duty cycle of the switch in the dc-dc converter using PID controller based PWM technique. The 60 V 30 A DC-DC SEPIC converter is designed to provide non-inverting voltage buck from the rectified AC mains for charging deep cycle battery bank in an electric auto rickshaw. The charger system is implemented using MATLABSimulink.

  8. Transformer-assisted PWM zero-voltage switching pole inverter with high output bandwidth applied to linear motor drives

    NARCIS (Netherlands)

    Myrzik, J.M.A.; Duarte, J.L.; Haardt, de P.; Vissers, J.

    2002-01-01

    An application of the transformer-assisted PWM zero-voltage switching pole inverter (TRAP) is described in this paper. The TRAP is based on the auxiliary resonant commutated pole inverter (ARCP), but avoids its disadvantages. This paper describes the converter functionality and its applicability

  9. Analysis of the Coupling Behavior of PEM Fuel Cells and DC-DC Converters

    Directory of Open Access Journals (Sweden)

    Achim Kienle

    2009-03-01

    Full Text Available The connection between PEM fuel cells and common DC-DC converters is examined. The analysis is model-based and done for boost, buck and buck-boost converters. In a first step, the effect of the converter ripples upon the PEM fuel cell is shown. They introduce oscillations in the fuel cell. Their appearance is explained, discussed and possibilities for their suppression are given. After that, the overall behaviors of the coupled fuel cell-converter systems are analyzed. It is shown, that neither stationary multiplicities nor oscillations can be introduced by the couplings and therefore separate control approaches for both the PEMFC and the DC-DC converters are applicable.

  10. Transformerless dc-Isolated Converter

    Science.gov (United States)

    Rippel, Wally E.

    1987-01-01

    Efficient voltage converter employs capacitive instead of transformer coupling to provide dc isolation. Offers buck/boost operation, minimal filtering, and low parts count, with possible application in photovoltaic power inverters, power supplies and battery charges. In photovoltaic inverter circuit with transformerless converter, Q2, Q3, Q4, and Q5 form line-commutated inverter. Switching losses and stresses nil because switching performed when current is zero.

  11. A New N-Level Inverter Based on Z-NPC

    Directory of Open Access Journals (Sweden)

    E. Babaei

    2017-12-01

    Full Text Available First of all, in this paper, the topology and operation of the three-phase three-level Z-source inverter based on neutral-point-clamped (Z-NPC are studied. Moreover, different combinations of permissible switching states and control signals are explained for this inverter. In this paper, the topology of the three-phase three-level Z-NPC inverter is extended for an n-level state. Also, a combination of allowed switching states with relevant mathematical equations is presented for the proposed n-level Z-NPC inverter. In comparison with multilevel voltage-source inverters (only voltage-boost capability, the proposed multilevel Z-NPC inverter is a single-stage converter and it has a buck-boost capability of voltage. On the other hand, the control of two-stage converters compared to single-stage converters can be more difficult because of existing more active and passive components. In this paper, two new PWM control methods are also proposed for various multilevel Z-NPC inverters. One advantage of the proposed PWM control methods in comparison with conventional PWM control methods is maintaining the charge balance of the dc-link capacitors in neutral point. The correct performance of the proposed multilevel Z-NPC topology and PWM control methods are verified by the obtained results of analysis and simulations performed in the PSCAD software.

  12. Analisys of Current-Bidirectional Buck-Boost Based Automotive Switch-Mode Audio Amplifier

    DEFF Research Database (Denmark)

    Bolten Maizonave, Gert; Andersen, Michael A. E.; Kjærgaard, Claus

    2011-01-01

    The following study was carried out in order to assess quantitatively the performance of the buck-boost converter when used as switch-mode audio amplifier. It comprises of, to begin with, the delimitation of design criteria based on the state-ofthe- art solution, which is based in a differential ...

  13. A study of DC-DC converters with MCT's for arcjet power supplies

    Science.gov (United States)

    Stuart, Thomas A.

    1994-01-01

    Many arcjet DC power supplies use PWM full bridge converters with large arrays of parallel FET's. This report investigates an alternative supply using a variable frequency series resonant converter with small arrays of parallel MCT's (metal oxide semiconductor controlled thyristors). The reasons for this approach are to: increase reliability by reducing the number of switching devices; and decrease the surface mounting area of the switching arrays. The variable frequency series resonant approach is used because the relatively slow switching speed of the MCT precludes the use of PWM. The 10 kW converter operated satisfactorily with an efficiency of over 91 percent. Test results indicate this efficiency could be increased further by additional optimization of the series resonant inductor.

  14. Predictive Trailing-Edge Modulation Average Current Control in DC-DC Converters

    Directory of Open Access Journals (Sweden)

    LASCU, D.

    2013-11-01

    Full Text Available The paper investigates predictive digital average current control (PDACC in dc/dc converters using trailing-edge modulation (TEM. The study is focused on the recurrence duty cycle equation and then stability analysis is performed. It is demonstrated that average current control using trailing-edge modulation is stable on the whole range of the duty cycle and thus design problems are highly reduced. The analysis is carried out in a general manner, independent of converter topology and therefore the results can then be easily applied for a certain converter (buck, boost, buck-boost, etc.. The theoretical considerations are confirmed for a boost converter first using the MATLAB program based on state-space equations and finally with the CASPOC circuit simulation package.

  15. Advanced buck converter power supply ABCPS for APT

    International Nuclear Information System (INIS)

    Street, R.; Overett, T.; Bowles, E.

    1998-01-01

    The United States Department of Energy (DOE) is planning to fabricate an Accelerator for the Production of Tritium (APT) at their Savannah River Site, to provide Tritium for national defense. The 1700 million electron volt (MeV) proton beam accelerator will be powered by radio frequency (RF) klystrons. A direct current (DC) power supply is required for each of the approximately two hundred and fifty 1-megawatt (MW) continuous wave klystrons in the RF power system. The requirements are that the power supply meet output performance specifications, provide fault protection for the klystron, have high efficiency, high reliability, good maintainability, and be readily manufacturable. As the power supplies are one of the largest cost elements in the accelerator, a technology review was made to determine the most economical approach to satisfy the requirements. A switch-mode power supply employing a buck-regulator was identified as being potentially the lowest cost approach. As the switch represents a certain development risk, a small-scale prototype has been constructed for evaluation, and has resulted in the decision to fabricate a full-scale prototype power supply. A description of the hardware will be presented

  16. The application of standardized control and interface circuits to three dc to dc power converters.

    Science.gov (United States)

    Yu, Y.; Biess, J. J.; Schoenfeld, A. D.; Lalli, V. R.

    1973-01-01

    Standardized control and interface circuits were applied to the three most commonly used dc to dc converters: the buck-boost converter, the series-switching buck regulator, and the pulse-modulated parallel inverter. The two-loop ASDTIC regulation control concept was implemented by using a common analog control signal processor and a novel digital control signal processor. This resulted in control circuit standardization and superior static and dynamic performance of the three dc-to-dc converters. Power components stress control, through active peak current limiting and recovery of switching losses, was applied to enhance reliability and converter efficiency.

  17. Large step-down DC-DC converters with reduced current stress

    International Nuclear Information System (INIS)

    Ismail, Esam H.

    2009-01-01

    In this paper, several DC-DC converters with large voltage step-down ratios are introduced. A simple modification in the output section of the conventional buck and quadratic converters can effectively extend the duty-cycle range. Only two additional components (an inductor and diode) are necessary for extending the duty-cycle range. The topologies presented in this paper show an improvement in the duty-cycle (about 40%) over the conventional buck and quadratic converters. Consequently, they are well suited for extreme step-down voltage conversion ratio applications. With extended duty-cycle, the current stress on all components is reduced, leading to a significant improvement of the system losses. The principle of operation, theoretical analysis, and comparison of circuit performances with other step-down converters is discussed regarding voltage and current stress. Experimental results of one prototype rated 40-W and operating at 100 kHz are provided in this paper to verify the performance of this new family of converters. The efficiency of the proposed converters is higher than the quadratic converters

  18. Soft switching bidirectional DC-DC converter for ultracapacitor-batteries interface

    International Nuclear Information System (INIS)

    Adib, Ehsan; Farzanehfard, Hosein

    2009-01-01

    In this paper a new soft switching bidirectional DC-DC converter is introduced which can be applied as the interface circuit between ultracapacitors and batteries or fuel cells. All semiconductor devices in the proposed converter are soft switched while the control circuit remains PWM. Due to achieved soft switching condition, the energy conversion through the proposed converter is highly efficient. The proposed converter is analyzed and a prototype converter is implemented. The presented experimental results confirm the theoretical analysis.

  19. Distortion-Free 1-Bit PWM Coding for Digital Audio Signals

    Directory of Open Access Journals (Sweden)

    John Mourjopoulos

    2007-01-01

    Full Text Available Although uniformly sampled pulse width modulation (UPWM represents a very efficient digital audio coding scheme for digital-to-analog conversion and full-digital amplification, it suffers from strong harmonic distortions, as opposed to benign non-harmonic artifacts present in analog PWM (naturally sampled PWM, NPWM. Complete elimination of these distortions usually requires excessive oversampling of the source PCM audio signal, which results to impractical realizations of digital PWM systems. In this paper, a description of digital PWM distortion generation mechanism is given and a novel principle for their minimization is proposed, based on a process having some similarity to the dithering principle employed in multibit signal quantization. This conditioning signal is termed “jither” and it can be applied either in the PCM amplitude or the PWM time domain. It is shown that the proposed method achieves significant decrement of the harmonic distortions, rendering digital PWM performance equivalent to that of source PCM audio, for mild oversampling (e.g., ×4 resulting to typical PWM clock rates of 90 MHz.

  20. Distortion-Free 1-Bit PWM Coding for Digital Audio Signals

    Directory of Open Access Journals (Sweden)

    Mourjopoulos John

    2007-01-01

    Full Text Available Although uniformly sampled pulse width modulation (UPWM represents a very efficient digital audio coding scheme for digital-to-analog conversion and full-digital amplification, it suffers from strong harmonic distortions, as opposed to benign non-harmonic artifacts present in analog PWM (naturally sampled PWM, NPWM. Complete elimination of these distortions usually requires excessive oversampling of the source PCM audio signal, which results to impractical realizations of digital PWM systems. In this paper, a description of digital PWM distortion generation mechanism is given and a novel principle for their minimization is proposed, based on a process having some similarity to the dithering principle employed in multibit signal quantization. This conditioning signal is termed "jither" and it can be applied either in the PCM amplitude or the PWM time domain. It is shown that the proposed method achieves significant decrement of the harmonic distortions, rendering digital PWM performance equivalent to that of source PCM audio, for mild oversampling (e.g., resulting to typical PWM clock rates of 90 MHz.

  1. Soft switching bidirectional DC-DC converter for ultracapacitor-batteries interface

    Energy Technology Data Exchange (ETDEWEB)

    Adib, Ehsan; Farzanehfard, Hosein [Dept. of Electrical and Computer Engineering, Isfahan Univ. of Technology (Iran)

    2009-12-15

    In this paper a new soft switching bidirectional DC-DC converter is introduced which can be applied as the interface circuit between ultracapacitors and batteries or fuel cells. All semiconductor devices in the proposed converter are soft switched while the control circuit remains PWM. Due to achieved soft switching condition, the energy conversion through the proposed converter is highly efficient. The proposed converter is analyzed and a prototype converter is implemented. The presented experimental results confirm the theoretical analysis. (author)

  2. Analisis Harmonisa Inverter PWM Satu Fasa

    OpenAIRE

    Rejeki Simanjorang

    2008-01-01

    Pada tesis ini dianalisis harmonisa inverter PWM satu fasa. Inverter PWM satu fasa yang akan ditinjau adalah inverter satu fasa jembatan penuh (konvensional) dan inverter komposit. Analisis difokuskan pada penentuan pola penyaklaran yang optimum agar pembangkitan harmonisa dan switching losses inverter rendah. Untuk menentukan pola penyaklaran optimum maka dilakukan analisis yang berbasis pada rangkaian ekivalen harmonisa inverter satu fasa. Dengan menggunakan pola penyaklaran optimum, kedua ...

  3. Analysis of current-bidirectional buck-boost based switch-mode audio amplifier

    DEFF Research Database (Denmark)

    Bolten Maizonave, Gert; Andersen, Michael A. E.; Kjærgaard, Claus

    2011-01-01

    The following studdy was carried out in order to assses quantitatively the performannce of the buck--boost converter whhen used as swiitch-mode audio amplifier. It comprises of, to beggin with, the de limitation of design criteria bassed on the state of-the-art solution, which is based...... in a differential mode buckbased amplifier with a boost converter as power supply. The averaged switch modelling of the differential mode current bidirectional topology is also used, in order to analyze the steady state and frequency-wise behaviour of this converter and parameterize it to meet the design criteria....... Next, several piecewise-linear siimulation resultss are shown with detail enough to emphasize the features of the converter. A simple prototype is implemented to verify the main predicted features. Presently no previous publicat ion could be found containing a thorough analysis of this topology...

  4. State-Trajectory Analysis and Control of LLC Resonant Converters

    OpenAIRE

    Feng, Weiyi

    2013-01-01

    With the fast development of communication systems, computers and consumer electronics, the power supplies for telecoms, servers, desktops, laptops, flat-panel TVs, LED lighting, etc. are required for more power delivery with smaller spaces. The LLC resonant converter has been widely adopted for these applications due to the advantages in high efficiency, high power density and holdup time operation capability.However, unlike PWM converters, the control of the LLC resonant converter is much m...

  5. Comparative efficiency evaluation of buck and hybrid buck DC-DC converters for automotive applications

    DEFF Research Database (Denmark)

    Pelan, Ovidiu; Cornea, Octavian; Muntean, Nicolae

    2014-01-01

    This paper presents and discusses design considerations and efficiency investigation of a conventional step-down and a hybrid switched-capacitor DC-DC converter. Three MOSFETs with low on-resistance have been tested for each converter in order to find the most adequate switch for this application....... The experimental results and comparative efficiency graphs were obtained with a 1kW laboratory prototype dedicated for a 42/14V dual voltage automotive system....

  6. State-plane analysis of parallel resonant converter

    Science.gov (United States)

    Oruganti, R.; Lee, F. C.

    1985-01-01

    A method for analyzing the complex operation of a parallel resonant converter is developed, utilizing graphical state-plane techniques. The comprehensive mode analysis uncovers, for the first time, the presence of other complex modes besides the continuous conduction mode and the discontinuous conduction mode and determines their theoretical boundaries. Based on the insight gained from the analysis, a novel, high-frequency resonant buck converter is proposed. The voltage conversion ratio of the new converter is almost independent of load.

  7. X-Y Converter Family

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Sanjeevikumar, Padmanaban; Wheeler, Patrick

    2016-01-01

    A New breed of a buck boost converter, named as the XY converter family is proposed in this article. In the XY family, 16 topologies are presented which are highly suitable for renewable energy applications which require a high ratio of DC-DC converter; such as a photovoltaic multilevel inverter...... system, high voltage automotive applications and industrial drives. Compared to the traditional boost converter and existing recent converters, the proposed XY converter family has the ability to provide a higher output voltage by using less number of power devices and reactive components. Other distinct...... features of the XY converter family are i) Single control switch ii) Provide negative output voltage iii) Non-isolated topologies iv) High conversion ratio without making the use of high duty cycle and v) modular structure. XY family is compared with the recent high step-up converters and the detailed...

  8. Optimal tree-stem bucking of northeastern species of China

    Science.gov (United States)

    Jingxin Wang; Chris B. LeDoux; Joseph McNeel

    2004-01-01

    An application of optimal tree-stem bucking to the northeastern tree species of China is reported. The bucking procedures used in this region are summarized, which are the basic guidelines for the optimal bucking design. The directed graph approach was adopted to generate the bucking patterns by using the network analysis labeling algorithm. A computer-based bucking...

  9. Research on Parallel Three Phase PWM Converters base on RTDS

    Science.gov (United States)

    Xia, Yan; Zou, Jianxiao; Li, Kai; Liu, Jingbo; Tian, Jun

    2018-01-01

    Converters parallel operation can increase capacity of the system, but it may lead to potential zero-sequence circulating current, so the control of circulating current was an important goal in the design of parallel inverters. In this paper, the Real Time Digital Simulator (RTDS) is used to model the converters parallel system in real time and study the circulating current restraining. The equivalent model of two parallel converters and zero-sequence circulating current(ZSCC) were established and analyzed, then a strategy using variable zero vector control was proposed to suppress the circulating current. For two parallel modular converters, hardware-in-the-loop(HIL) study based on RTDS and practical experiment were implemented, results prove that the proposed control strategy is feasible and effective.

  10. Effect of 60Co γ-rays on PWM and LPS induced lymphocytes

    International Nuclear Information System (INIS)

    Su Liaoyuan; Liu Keliang; Liu Fenju

    1987-01-01

    The relationship between lymphocytes induced by PWM (pokeweed mitogen) and LPS (lipopolysaccharide) was investigated by means of 3 H-TdR incorporation. The study showed that, in vitro, PWM-induced cells were able to promote the stimulating effect of LPS to B lymphocytes. The stimulating effect of PWM-induced cells was obviously weakened after PWM cells being irradiated with γ-rays. When PWM-induced cells and LPS-induced cells were incubated together, with one kind of cells exposed to 60 Co γ-ray, incorporation value of 3 H-TdR became much smaller and the synergetic function disappeared, especially, when PWM-induced cells were irradiated. For patients suffering from carcinoma of nasopharynx, while treated with 60 Co γ-rays, the incorporation value in LPS-induced cells approached normal level, meanwhile, the incorporation value in PEM-induced cells reduced significantly and the stimulating effect of PWM-induced cells on LPS-induced cells became much weaker. The facts described above demonstrated that PWM-induced cells have the function of T-helper cells and play more important role in the synergy than LPS-induced cells

  11. Overmodulation of n-level three-leg DC-AC diode-clamped converters with comprehensive capacitor voltage balance

    DEFF Research Database (Denmark)

    Busquets-Monge, S.; Maheshwari, Ram Krishan; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories are selec......This paper presents a novel PWM strategy for nlevel three-leg semiconductor-clamped dc-ac converters in the overmodulation region, with dc-link capacitor voltage balance in every switching cycle. The strategy is based on the virtual-vector concept. Suitable reference vector trajectories...

  12. Optimal Selective Harmonic Mitigation Technique on Variable DC Link Cascaded H-Bridge Converter to Meet Power Quality Standards

    DEFF Research Database (Denmark)

    Najjar, Mohammad; Moeini, Amirhossein; Dowlatabadi, Mohammadkazem Bakhshizadeh

    2016-01-01

    In this paper, the power quality standards such as IEC 61000-3-6, IEC 61000-2-12, EN 50160, and CIGRE WG 36-05 are fulfilled for single- and three-phase medium voltage applications by using Selective Harmonic Mitigation-PWM (SHM-PWM) in a Cascaded H-Bridge (CHB) converter. Furthermore, the ER G5/...

  13. Research of digital controlled DC/DC converter based on STC12C5410AD

    Science.gov (United States)

    Chen, Dan-Jiang; Jin, Xin; Xiao, Zhi-Hong

    2010-02-01

    In order to study application of digital control technology on DC/DC converter, principle of increment mode PID control algorithm was analyzed in the paper. Then, a SCM named STC12C5410AD was introduced with its internal resources and characteristics. The PID control algorithm can be implemented easily based on it. The output of PID control was used to change the value of a variable that is 255 times than duty cycle, and this reduced the error of calculation. The valid of the presented algorithm was verified by an experiment for a BUCK DC/DC converter. The experimental results indicated that output voltage of the BUCK converter is stable with low ripple.

  14. A High-Precision Control for a ZVT PWM Soft-Switching Inverter to Eliminate the Dead-Time Effect

    Directory of Open Access Journals (Sweden)

    Baoquan Kou

    2016-07-01

    Full Text Available Attributing to the advantages of high efficiency, low electromagnetic interference (EMI noise and closest to the pulse-width-modulation (PWM converter counterpart, zero-voltage-transition (ZVT PWM soft-switching inverters are very suitable for high-performance applications. However, the conventional control algorithms intended for high efficiency generally results in voltage distortion. Thus, this paper, for the first time, proposes a high-precision control method to eliminate the dead-time effect through controlling the auxiliary current in the auxiliary resonant snubber inverter (ARSI, which is a typical ZVT PWM inverter. The dead-time effect of ARSI is analyzed, which is distinguished from hard-switching inverters. The proposed high-precision control is introduced based on the investigation of dead-time effect. A prototype was developed to verify the effectiveness of the proposed control. The experimental results shows that the total harmonic distortion (THD of the output current of the ARSI can be reduced compared with that of the hard-switching inverter, because the blanking delay error is eliminated. The quality of the output current and voltage can be further improved by utilizing the proposed control method.

  15. A new Zero-Current-Transition PWM switching cell

    Energy Technology Data Exchange (ETDEWEB)

    Grigore, V. [Electronics and Telecommunications Faculty, `Politechnica` University Bucharest (Romania); Kyyrae, J. [Helsinki University of Technology, Otaniemi (Finland): Institute of Intelligent Power Electronics

    1997-12-31

    In this paper a new Zero-Current-Transition (ZCT) PWM switching cell is presented. The proposed switching cell is composed of the normal hard-switched PWM cell (consisting of one active switch and one passive switch), plus as auxiliary circuit. The auxiliary circuit is inactive during the ON ad OFF intervals of the switches in the normal PWM switch. The transitions between the two states are controlled by the auxiliary circuit. Prior to turn-off, the current through the active switch in the PWM cell is forced to zero, thus the turn-off losses of the active switch are practically eliminated. At turn-on the auxiliary circuit slows down the growing rate of the current through the main switch. Thus, turn-on losses are also very much reduced. The active switch operates under ZCT conditions, the passive switch (diode) has a controlled reverse recovery, while the switch in the auxiliary circuit operates under Zero-Current-Switching (ZCS) conditions. (orig.) 3 refs.

  16. Color adjustable LED driver design based on PWM

    Science.gov (United States)

    Du, Yiying; Yu, Caideng; Que, Longcheng; Zhou, Yun; Lv, Jian

    2012-10-01

    Light-emitting diode (LED) is a liquid cold source light source that rapidly develops in recent years. The merits of high brightness efficiency, long duration, high credibility and no pollution make it satisfy our demands for consumption and natural life, and gradually replace the traditional lamp-house-incandescent light and fluorescent light. However, because of the high cost and unstable drive circuit, the application range is restricted. To popularize the applications of the LED, we focus on improving the LED driver circuit to change this phenomenon. Basing on the traditional LED drive circuit, we adopt pre-setup constant current model and introduce pulse width modulation (PWM) control method to realize adjustable 256 level-grays display. In this paper, basing on human visual characteristics and the traditional PWM control method, we propose a new PWM control timing clock to alter the duty cycle of PWM signal to realize the simple gamma correction. Consequently, the brightness can accord with our visual characteristics.

  17. multilevel buck converter for automotive electrical load

    African Journals Online (AJOL)

    ... from internal combustion engine (ICE). The mass production of the hybrid electric (HE) and the electric vehicle (EV) is still awaited due to subsystem inefficiencies. Increasing the efficiencies of the power converters within subsystems of these HEVs and EVs will increase the performance of the new transportation vehicles.

  18. Switching power converters medium and high power

    CERN Document Server

    Neacsu, Dorin O

    2013-01-01

    An examination of all of the multidisciplinary aspects of medium- and high-power converter systems, including basic power electronics, digital control and hardware, sensors, analog preprocessing of signals, protection devices and fault management, and pulse-width-modulation (PWM) algorithms, Switching Power Converters: Medium and High Power, Second Edition discusses the actual use of industrial technology and its related subassemblies and components, covering facets of implementation otherwise overlooked by theoretical textbooks. The updated Second Edition contains many new figures, as well as

  19. An improved soft switched PWM interleaved boost AC-DC converter

    International Nuclear Information System (INIS)

    Genc, Naci; Iskender, Ires

    2011-01-01

    In this paper, an improved soft switched two cell interleaved boost AC/DC converter with high power factor is proposed and investigated. A new auxiliary circuit is designed and added to two cell interleaved boost converter to reduce the switching losses. The proposed auxiliary circuit is implemented using only one auxiliary switch and a minimum number of passive components without an important increase in the cost and complexity of the converter. The main advantage of this auxiliary circuit is that it not only provides zero-voltage-transition (ZVT) for the main switches but also provides soft switching for the auxiliary switch and diodes. Though all semiconductor devices operate under soft switching, they do not have any additional voltage and current stresses. The proposed converter operates successfully in soft switching operation mode for a wide range of input voltage level and the load. In addition, it has advantages such as fewer structure complications, lower cost and ease of control. In the study, the transition modes for describing the behavior of the proposed converter in one switching period are described. A prototype with 600 W output power, 50 kHz/cell switching frequency, input line voltage of 110-220 V rms and an output voltage of 400 V dc has been implemented. Analysis, design and the control circuitry are also presented in the paper.

  20. On the Suitability of Interleaved Switched Capacitor Converter as an Interface for Electric Vehicle Dual Energy Storage Systems

    Energy Technology Data Exchange (ETDEWEB)

    Amjadi, Zahra; Williamson, Sheldon

    2010-09-15

    This paper presents the analysis and novel hybrid controller design for an interleaved 2-quadrant switched capacitor (SC) bidirectional DC/DC converter for a hybrid electric vehicle (HEV) dual energy storage system. The designed novel control strategy enables simpler dynamics compared to a standard buck converter with input filter, good regulation capability, low EMI, lower source current ripple, ease of control, and continuous input current waveform in both buck as well as boost modes of operation.

  1. A new Zero-Voltage-Transition PWM switching cell

    Energy Technology Data Exchange (ETDEWEB)

    Grigore, V. [Electronics and Telecommunications Faculty `Politebuica` University Bucharest (Romania); Kyyrae, J. [Helsinki University of Technology, Otaniemi (Finland): Institute of Intelligent Power Electronics

    1997-12-31

    In this paper a new Zero-Voltage-Transition (ZVT) PWM switching cell is presented. The proposed switching cell is composed of the normal hard-switched PWM cell (consisting of one active switch and one passive switch), plus an auxiliary circuit (consisting of one active switch and some reactive components). The auxiliary circuit is inactive during the ON and OFF intervals of the switches in the normal PWM switch. However, the transitions between the two states are controlled by the auxiliary circuit. Prior to turn-on, the voltage across the active switch in the PWM cell is forced to zero, thus the turn-on losses of the active switch are practically eliminated. At turn-off the auxiliary circuit behaves like a non-dissipative passive snubber reducing the turn-off losses to a great extent. Zero-Voltage-Transition switching technique almost eliminates switching losses. The active switch operates under ZVT conditions, the passive switch (diode) has a controlled reverse recovery, and the switch in the auxiliary circuit operates under Zero-Current-Switching (ZCS) conditions. (orig.) 6 refs.

  2. Self oscillating PWM modulators, a topological comparison

    DEFF Research Database (Denmark)

    Poulsen, Søren; Andersen, Michael Andreas E.

    2004-01-01

    or fs/ð range respectively, where fs is the switching frequency of the converter. For some applications this will require unacceptable high switching frequency to achieve enough control loop bandwidth for the desired dynamic performance. With self oscillating modulators, the open loop bandwidth is equal...... to fs which makes this type of modulators an excellent choice for a wide range of applications. Self oscillating PWM modulators can be made in a number of ways, either as voltage or current mode modulators, and the self oscillating behavior can be achieved either by using hysteresis control...... or by shaping the open loop function of the modulator so its gain and phase response causes a closed loop natural oscillation. The two main types of self oscillating modulators have many similarities, but differences in dynamic performance and linearity are present. The work presented is related to the author...

  3. Realise of PWM-generating based on FPGA

    International Nuclear Information System (INIS)

    Su Rongfeng; Xu Ruinian; Huang Maomao

    2012-01-01

    The power supply digital controllers of Shanghai Synchrotron Radiation Facility(SSRF) make use of the PWM (pulse width modulation) wave as the feedback to the power-electrical devices, so as to obtain constant current of high accuracy and stability. The design of PWM wave generation structure in FPGA is good for a compact controller,and the reduction of the usage of Integrated Circuits (ICs) decreases the interference from the noise among the ICs, hence better performance of the controller. In addition, FPGA can be programmed circularly at any time,so as to optimize the structure design and make a maximum use of the advantage of FPGA. As a part of transplanting the complete function of the DSP (digital signal processor/processing), realizing the generation of PWM wave in FPGA is feasible. In this paper, we report progress in this regard at SSRF. (authors)

  4. Power Quality Control and Design of Power Converter for Variable-Speed Wind Energy Conversion System with Permanent-Magnet Synchronous Generator

    Directory of Open Access Journals (Sweden)

    Yüksel Oğuz

    2013-01-01

    Full Text Available The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.

  5. Power quality control and design of power converter for variable-speed wind energy conversion system with permanent-magnet synchronous generator.

    Science.gov (United States)

    Oğuz, Yüksel; Güney, İrfan; Çalık, Hüseyin

    2013-01-01

    The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS) operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.

  6. Bidirectional DC-DC converter fed drive for electric vehicle system

    African Journals Online (AJOL)

    ATHARVA

    of converters can be connected in series or parallel with low switching frequency (Yu and Lai, 2008). ... reversed, the topology functions as a buck converter through the modulation of Q1 , with the .... The state space average model is shown in (9) and (10). │. ⌋. ⌉ .... terms of high energy density, compact size and reliability.

  7. A Three-level 4 x 3 Conventinal Matrix Converter

    DEFF Research Database (Denmark)

    Rong, Runjie; Loh, Poh Chiang; Wang, Peter

    2007-01-01

    This paper proposes a topology of a three-level 4 × 3 conventional matrix converter with 12 bi-directional switches. PWM control and modulation index compensation have been investigated. Operation theory has been verified by the simulation results using Matlab. The simulation results show...

  8. A unified triangle carrier based PWM strategy for three-phase N-level diode clamped inverters

    DEFF Research Database (Denmark)

    Li, Kai; Xie, Chuan; Wei, Min

    2017-01-01

    The triangle carrier based pulse width modulation (TCB-PWM) can be functionally equivalent to space vector base PWM (SVB-PWM). For multi-level inverter, it is very difficult to realize the SVB-PWM because its vector space is very complex. In this paper, a unified TCB-PWM strategy for three-phase ...

  9. Pengaruh Penambahan PWM (Pulse Width Modulation Pada Generator HHO Tipe Dry Cell

    Directory of Open Access Journals (Sweden)

    Fungky Dyan Pertiwi

    2013-09-01

    Full Text Available Generator HHO memanfaatkan proses elektrolisis air agar mendapatkan gas H2. Namun, pada praktiknya pemakaian arus dari aki yang besar dan temperatur tinggi membuat bejana generator menjadi cepat rusak, sehingga dibutuhkan tambahan rangkaian elektronika PWM pada pengujian generator HHO guna mengatasi permasalahan tersebut. Penelitian menggunakan elektroda plat berjumlah 9 berdimensi 120mm 120mm, tebal 1mm dan dibatasi oleh o-ring dengan diameter 126mm, tebal 3mm. Pengujian dilakukan secara eksperimen dengan 2 kelompok yaitu kelompok control yang mana pengujian tanpa menggunakan PWM serta kelompok uji dimana pengujian menggunakan PWM dengan variasi duty cycle 30%, 50% dan 70%. Pengujian dilakukan hingga temperatur elektrolit 93oC. Hasil uji didapatkan bahwa arus, laju produksi dan efisiensi terbesar didapatkan pada pengujian tanpa PWM yang mencapai 60,6A, 6,033 10-6kg/s dan 25,69%. Namun, pada pengambilan data kedua efisiensi turun menjadi 19,74%. Penambahan PWM pada pengujian berpengaruh pada arus dan temperatur yang stabil meskipun laju produksi dan efisiensi lebih kecil daripada pengujian tanpa PWM. Pengujian dengan PWM pada duty cycle 70% menghasilkan laju produksi dan efisiensi terbesar yang mencapai 1,843 10-6 kg/s dan 15,19%.

  10. PWM CONTROLLER'S MODELS FOR INVESTIGATION ACS IN SPICEFAMILY ECAD PROGRAMS

    Directory of Open Access Journals (Sweden)

    O. V. VASYLENKO

    2018-05-01

    Full Text Available Purpose. To improve simulation and design of Automatic Control Systems in the SPICE-compatible programs and to obtain separate economic and universal macromodels of PWM controller. Development of an PWM controller economical macromodel for the study of automatic control systems (ACS in computer-aided design (ECAD  programs, which does not generate algorithmic failures in comparison with the existing models of PWM. Findings. Analysis of SPICE-family applications’ mathematical basis allowed to classifying existing models of PWM-controllers, defining their suitability for ACS simulation. The criteria for the synthesis of new models have been defined. For the SPICE 3G algorithms, the Switch and Averaged models based on behavioral elements has been developed. Universal and economical PWM controller macromodel based on the simple algorithm for determining the output signal with minimum numbers of input parameters has been designed. For the Automated Measuring magnetic susceptibility System, the macromodel of quasi-PWM signal generator have been designed, which is used in the compensation subsystem. This model is different from the existing ones: it synthesizes the staircase output signal instead the pulse one, thus, there is direct control of the amplitude of the output signal, which is taken averaged. The adequacy of the models is confirmed as comparison of the simulation results during investigations of the model already existing in the SPICE program, as well as the results of experiments with real ACS. The modeling of the PWM controller was carried out on the basis of behavioral elements from the ECAD library, simulation (solution of algebra-differential equations systems with programming elements is based on SPICE algorithms. The object of the study was the simulation process of ACS with the pulse-width principle of adjusting the output value. The subject of the research are the models of PWM controllers. Originality. The new macromodel of PWM

  11. Modeling and analysis of fractional order DC-DC converter.

    Science.gov (United States)

    Radwan, Ahmed G; Emira, Ahmed A; AbdelAty, Amr M; Azar, Ahmad Taher

    2017-07-11

    Due to the non-idealities of commercial inductors, the demand for a better model that accurately describe their dynamic response is elevated. So, the fractional order models of Buck, Boost and Buck-Boost DC-DC converters are presented in this paper. The detailed analysis is made for the two most common modes of converter operation: Continuous Conduction Mode (CCM) and Discontinuous Conduction Mode (DCM). Closed form time domain expressions are derived for inductor currents, voltage gain, average current, conduction time and power efficiency where the effect of the fractional order inductor is found to be strongly present. For example, the peak inductor current at steady state increases with decreasing the inductor order. Advanced Design Systems (ADS) circuit simulations are used to verify the derived formulas, where the fractional order inductor is simulated using Valsa Constant Phase Element (CPE) approximation and Generalized Impedance Converter (GIC). Different simulation results are introduced with good matching to the theoretical formulas for the three DC-DC converter topologies under different fractional orders. A comprehensive comparison with the recently published literature is presented to show the advantages and disadvantages of each approach. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  12. Switched-mode converters (one quadrant)

    CERN Document Server

    Barrade, P

    2006-01-01

    Switched-mode converters are DC/DC converters that supply DC loads with a regulated output voltage, and protection against overcurrents and short circuits. These converters are generally fed from an AC network via a transformer and a conventional diode rectifier. Switched-mode converters (one quadrant) are non-reversible converters that allow the feeding of a DC load with unipolar voltage and current. The switched-mode converters presented in this contribution are classified into two families. The first is dedicated to the basic topologies of DC/DC converters, generally used for low- to mid-power applications. As such structures enable only hard commutation processes, the main drawback of such topologies is high commutation losses. A typical multichannel evolution is presented that allows an interesting decrease in these losses. Deduced from this direct DC/DC converter, an evolution is also presented that allows the integration of a transformer into the buck and the buck–boost structure. This enables an int...

  13. Design of High-Voltage Switch-Mode Power Amplifier Based on Digital-Controlled Hybrid Multilevel Converter

    Directory of Open Access Journals (Sweden)

    Yanbin Hou

    2016-01-01

    Full Text Available Compared with conventional Class-A, Class-B, and Class-AB amplifiers, Class-D amplifier, also known as switching amplifier, employs pulse width modulation (PWM technology and solid-state switching devices, capable of achieving much higher efficiency. However, PWM-based switching amplifier is usually designed for low-voltage application, offering a maximum output voltage of several hundred Volts. Therefore, a step-up transformer is indispensably adopted in PWM-based Class-D amplifier to produce high-voltage output. In this paper, a switching amplifier without step-up transformer is developed based on digital pulse step modulation (PSM and hybrid multilevel converter. Under the control of input signal, cascaded power converters with separate DC sources operate in PSM switch mode to directly generate high-voltage and high-power output. The relevant topological structure, operating principle, and design scheme are introduced. Finally, a prototype system is built, which can provide power up to 1400 Watts and peak voltage up to ±1700 Volts. And the performance, including efficiency, linearity, and distortion, is evaluated by experimental tests.

  14. Control of a resonant d.c.-link converter for a.c. motor drives

    Directory of Open Access Journals (Sweden)

    Astrid Petterteig

    1992-10-01

    Full Text Available This paper presents the control of the resonant d.c.-link converter for a.c. motor drives. This is a low loss converter with higher efficiency than a conventional PWM converter, but it requires complex control. It needs a special control of the resonant d.c.-link voltage in addition to the discrete control of the a.c. side currents. Simulations show how the control of the a.c. currents, the modulation principle, influences the overall performance of the converter.

  15. Application research of power allocation based on Buck circuit in DC microgrid

    OpenAIRE

    Wang Zihao; Zhou Mingyu

    2017-01-01

    In a traditional DC microgrid, the power sharing control strategy has been always used in the distributed power converters, resulting in not making outer power allocation arbitrarily. In order to solve the power output allocation problem of wind power in DC microgrid, the intelligent Buck circuit based on PI algorithm and the load current feed-forward method was used to realize the arbitrary regulation of the output power of the wind power in the DC microgrid system. Compared with traditional...

  16. SYNTHESIS OF VOLTAGES OF UNIFORM PWM IN TIME REGULATION

    Directory of Open Access Journals (Sweden)

    A. G. Stryzhniou

    2014-01-01

    Full Text Available The article describes a process of synthesis and qualitative assessment of the harmonic composition of voltages of multiple and single PWM pulses in time regulation, being, along with amplitude, frequency and phase method, one of control methods of an asynchronous motor. The main point of time regulation is that a pause after any two single PWM pulses with different polarity or after any two groups of multiple PWM pulses with different polarity changes during a process of regulation. Feature of time regulation is that a motor has fast response in the range of small-signal of control and good linearity of speed-torque characteristics in the whole control range. Analytical expressions of parameters of PWM pulses ai and ti are obtained which allow to simplify considerably a process of formation and implementation of time regulation using tabular or indexed-tabular methods. These expressions allow not only to define voltage amplitude of  harmonic but also to perform qualitative assessment of harmonic composition of output voltages at time regulation. It is specified that harmonic frequencies wi = w0/q change in inverse proportion to magnitude of parameter q during a process of regulation and there is a replacement of a fundamental frequency by frequencies of higher harmonics.The offered approach allows to synthesize voltage of uniform single and multiple PWM pulses and to perform their comparative and qualitative analysis and the obtained expressions can be used at modeling of AC motor work. Voltage of multiple PWM pulses which is formed using stepped reference voltage with even quantity of steps in a half period and a pause on a zero level has the best parameters by criterion of a minimum of harmonic components and a maximum of a factor of anharmonicity Kнс at time regulation.

  17. A soft switching with reduced voltage stress ZVT-PWM full-bridge converter

    Science.gov (United States)

    Sahin, Yakup; Ting, Naim Suleyman; Acar, Fatih

    2018-04-01

    This paper introduces a novel active snubber cell for soft switching pulse width modulation DC-DC converters. In the proposed converter, the main switch is turned on under zero voltage transition and turned off under zero voltage switching (ZVS). The auxiliary switch is turned on under zero current switching (ZCS) and turned off under zero current transition. The main diode is turned on under ZVS and turned off under ZCS. All of the other semiconductors in the converter are turned on and off with soft switching. There is no extra voltage stress on the semiconductor devices. Besides, the proposed converter has simple structure and ease of control due to common ground. The detailed theoretical analysis of the proposed converter is presented and also verified with both simulation and experimental study at 100 kHz switching frequency and 600 W output power. Furthermore, the efficiency of the proposed converter is 95.7% at nominal power.

  18. Buck-Boost Current-Source Inverters With Diode-Inductor Network

    DEFF Research Database (Denmark)

    Gao, Feng; Liang, Chao; Loh, Poh Chiang

    2009-01-01

    This paper presents a number of novel currentsource inverters (CSIs) with enhanced current buck-boost capability. By adding a unique diode-inductor network between the inverter circuitry and current-boost elements, the proposed buck-boost CSIs demonstrate a doubling of current-boost capability......, as compared with other recently reported buck-boost CSIs. For controlling the proposed CSIs, two modulation schemes are designed for achieving either optimized harmonic performance or minimized commutation count without influencing the inverter current buck-boost gain. These theoretical findings were...

  19. A new soft switched push pull current fed converter for fuel cell applications

    International Nuclear Information System (INIS)

    Delshad, Majid; Farzanehfard, Hosein

    2011-01-01

    In this paper a new zero voltage switching current fed push pull dc-dc converter is proposed for fuel cell generation system. The auxiliary circuit in this converter, not only absorbs the voltage surge across the switches at turn off instance, but also provides zero voltage switching condition for all converter switches. Therefore, the converter efficiency is increased and size and weight of the converter can be decreased. Also implementation of control circuit is very simple since the converter is PWM controlled. In this paper, the proposed dc-dc converter operating modes are analyzed and to verify the converter operation a laboratory prototype is implemented and the experimental results are presented.

  20. A Reconfigurable Buck, Boost, and Buck-Boost Converter: Unified Model and Robust Controller

    OpenAIRE

    Licea, Martín Antonio Rodríguez; Pinal, Francisco Javier Perez; Gutiérrez, Alejandro Israel Barranco; Ramírez, Carlos Alonso Herrera; Perez, Jose Cruz Nuñez

    2018-01-01

    The need for reconfigurable, high power density, and low-cost configurations of DC-DC power electronic converters (PEC) in areas such as the transport electrification and the use of renewable energy has spread out the requirement to incorporate in a single circuit several topologies, which generally result in an increment of complexity about the modeling, control, and stability analyses. In this paper, a reconfigurable topology is presented which can be applied in alterative/changing power co...

  1. Analysis of Input and Output Ripples of PWM AC Choppers

    Directory of Open Access Journals (Sweden)

    Pekik Argo Dahono

    2008-11-01

    Full Text Available This paper presents an analysis of input and output ripples of PWM AC choppers. Expressions of input and output current and voltage ripples of single-phase PWM AC choppers are first derived. The derived expressions are then extended to three-phase PWM AC choppers. As input current and output voltage ripples specification alone cannot be used to determine the unique values of inductance and capacitance of the LC filters, an additional criterion based on the minimum reactive power is proposed. Experimental results are included in this paper to show the validity of the proposed analysis method.

  2. A digital input class-D audio amplifier with sixth-order PWM

    International Nuclear Information System (INIS)

    Luo Shumeng; Li Dongmei

    2013-01-01

    A digital input class-D audio amplifier with a sixth-order pulse-width modulation (PWM) modulator is presented. This modulator moves the PWM generator into the closed sigma—delta modulator loop. The noise and distortions generated at the PWM generator module are suppressed by the high gain of the forward loop of the sigma—delta modulator. Therefore, at the output of the modulator, a very clean PWM signal is acquired for driving the power stage of the class-D amplifier. A sixth-order modulator is designed to balance the performance and the system clock speed. Fabricated in standard 0.18 μm CMOS technology, this class-D amplifier achieves 110 dB dynamic range, 100 dB signal-to-noise rate, and 0.0056% total harmonic distortion plus noise. (semiconductor integrated circuits)

  3. How stem defects affect the capability of optimum bucking method?

    Directory of Open Access Journals (Sweden)

    Abdullah Emin Akay

    2015-07-01

    Full Text Available In forest harvesting activities, computer-assisted optimum bucking method increases the economic value of harvested trees. The bucking decision highly depends on the log quality grades which mainly vary with the surface characteristics such as stem defects and form of the stems. In this study, the effects of stem defects on optimum bucking method was investigated by comparing bucking applications which were conducted during the logging operations in two different Brutian Pine (Pinus brutia Ten stands. In the applications, the first stand contained the stems with relatively more stem defects than that of the stems in the second stand. The average number of defects per log for sample trees in the first and the second stand was recorded as 3.64 and 2.70, respectively. The results indicated that optimum bucking method increased the average economic value of harvested trees by 15.45% and 8.26 % in the stands, respectively. Therefore, the computer-assisted optimum bucking method potentially provides better results than that of traditional bucking method especially for the harvested trees with more stem defects.

  4. Diseño, modelado e implementación de inversor conectado a la red eléctrica a partir de fuentes renovables

    Directory of Open Access Journals (Sweden)

    César Leonardo Trujillo Rodríguez

    2012-06-01

    Full Text Available This paper describes the design, modeling and implementation of a single-phase inverter connected to the grid from renewable energy sources. We study the model in small signal to be below the control loops design it. In order to control the injection of energy into the grid from renewable is proposed for average current control (ACC. Drivers are obtained through the analysis applied to the small signal model obtained from the PWM switch model and the approach of the investor to a Buck converter. Finally, simulations and experimental tests conducted to validate the transient response and steady-state investor.

  5. Investigation and improvement of high step- up converters for pv module applications

    Directory of Open Access Journals (Sweden)

    Hamed moradmand jazi

    2017-01-01

    Full Text Available sun is of the clean and cheapest sources of energy. Charging slight energy to electricity is carried out by PV modules. Since most electric consumers need Ac input voltage, the PV modules output voltage should be changed into Ac form. But, the voltage level of PV modules is much lower than the voltage needed in input stage of inverters. Because of large voltage level. Difference it is not possible to use the basic boost and buck-boost converters. The basic boost and buck-boost converters definitely can not be used in this applications, for, they will face extreme drop in efficiency in duty cycles closer to unity. In this paper The proposed converter is presented in order to decrease the voltage stress of coupled inductors based high step-up converters. The voltage stress in the proposed converter is lower than the high step-up boost converter with coupled inductors in identical condition. Also, soft switching condition for switches and diodes is realized by active clamp circuit, and with this technique and proper selection of duty cycle, large gain and high efficiency could be achieved ultimately. . In this paper theoretical analysis is used for analyzing the performance of the proposed converters, and in order to verify the theoretical analysis, simulated results from pspice software is provides.

  6. Analysis, Design, Modeling, and Control of an Interleaved-Boost Full-Bridge Three-Port Converter for Hybrid Renewable Energy Systems

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Zhang, Zhe; Knott, Arnold

    2017-01-01

    This paper presents the design, modeling, and control of an isolated dc-dc three-port converter (TPC) based on an interleaved-boost full-bridge converter with pulsewidth modulation (PWM) and phase-shift control for hybrid renewable energy systems. In the proposed topology, the switches are driven...

  7. High-frequency high-voltage high-power DC-to-DC converters

    Science.gov (United States)

    Wilson, T. G.; Owen, H. A.; Wilson, P. M.

    1982-09-01

    A simple analysis of the current and voltage waveshapes associated with the power transistor and the power diode in an example current-or-voltage step-up (buck-boost) converter is presented. The purpose of the analysis is to provide an overview of the problems and design trade-offs which must be addressed as high-power high-voltage converters are operated at switching frequencies in the range of 100 kHz and beyond. Although the analysis focuses on the current-or-voltage step-up converter as the vehicle for discussion, the basic principles presented are applicable to other converter topologies as well.

  8. Design of a High Performance Green-Mode PWM Controller IC with Smart Sensing Protection Circuits

    Directory of Open Access Journals (Sweden)

    Shen-Li Chen

    2014-08-01

    Full Text Available A design of high performance green-mode pulse-width-modulation (PWM controller IC with smart sensing protection circuits for the application of lithium-ion battery charger (1.52 V ~ 7.5 V is investigated in this paper. The protection circuits architecture of this system mainly bases on the lithium battery function and does for the system design standard of control circuit. In this work, the PWM controller will be with an automatic load sensing and judges the system operated in the operating mode or in the standby mode. Therefore, it reduces system’s power dissipation effectively and achieves the saving power target. In the same time, many protection sensing circuits such as: (1 over current protection (OCP and under current protection (UCP, (2 over voltage protection (OVP and under voltage protection (UVP, (3 loading determintion and short circuit protection (SCP, (4 over temperature protection (OTP, (5 VDD surge-spiking protection are included. Then, it has the characteristics of an effective monitoring the output loading and the harm prevention as a battery charging. Eventually, this green-mode pulse-width-modulation (PWM controller IC will be that the operation voltage is 3.3 V, the operation frequency is 0.98 MHz, and the output current range is from 454 mA to 500 mA. Meanwhile, the output convert efficiency is range from 74.8 % to 91 %, the power dissipation efficiency in green-mode is 25 %, and the operation temperature range is between -20 0C ~ 114 0C.

  9. Primary Paralleled Isolated Boost Converter with Extended Operating Voltage Range

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Sen, Gökhan; Mira Albert, Maria del Carmen

    2012-01-01

    Applications requiring wide input and output voltage range cannot often be satisfied by using buck or boost derived topologies. Primary paralleled isolated boost converter (PPIBC) [1]-[2] is a high efficiency boost derived topology. This paper proposes a new operation mode for extending the input...

  10. Feedforward Synchronised PWM for Adjustable Speed AC Drives with Different Control Modes

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede; Jensen, Flemming Buus

    2002-01-01

    This paper presents a novel method of direct synchronised pulswidth modulation (PWM) for three-phase voltage source inverters, feeding induction motors with different control regimes. It is based on the universal algorithm with either simplified algebraic or accurate trigonometric control functions......, with vector approached for determination of the pulse patterns, with vector approach for determination of the pulse patterns. Different control modes of the drive system with synchronised PWM, including standard scalar V/F control, and also V2/F = constant and V/F2 = constant control regimes, have been...... analysed in the paper. Simulations give the behaviour of the PWM techniques proposed. Both continuous and discontinuous schemes of synchronised PWM, applied for the corresponding control regime, have been analysed and compared....

  11. A High Power Density Single-Phase PWM Rectifier With Active Ripple Energy Storage

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ruxi [Virginia Polytechnic Institute and State University (Virginia Tech); Wang, Fei [ORNL; Boroyevich, Dushan [Virginia Polytechnic Institute and State University (Virginia Tech); Burgos, Rolando [ABB; Lai, Rixin [General Electric; Ning, Puqi [ORNL; Rajashekara, Kaushik [Rolls Royce

    2011-01-01

    It is well known that single-phase pulse width modulation rectifiers have second-order harmonic currents and corresponding ripple voltages on the dc bus. The low-frequency harmonic current is normally filtered using a bulk capacitor in the bus, which results in low power density. However, pursuing high power density in converter design is a very important goal in the aerospace applications. This paper studies methods for reducing the energy storage capacitor for single-phase rectifiers. The minimum ripple energy storage requirement is derived independently of a specific topology. Based on theminimum ripple energy requirement, the feasibility of the active capacitor s reduction schemes is verified. Then, we propose a bidirectional buck boost converter as the ripple energy storage circuit, which can effectively reduce the energy storage capacitance. The analysis and design are validated by simulation and experimental results.

  12. Prediction of power losses in silicon iron sheets under PWM voltage supply

    International Nuclear Information System (INIS)

    Amar, M.; Kaczmarek, R.; Protat, F.

    1994-01-01

    The behavior of iron losses in silicon iron steels submitted to a PWM voltage is studied. The influence of modulation parameters (the depth of modulation and the number of eliminated harmonics) is clarified. In particular, the idea of an equivalent alternating pulse voltage that gives the same iron losses as the PWM voltage is established. An estimation formula for iron losses under the PWM voltage is developed based on the loss separation model and the voltage form factor. ((orig.))

  13. A Hamiltonian viewpoint in the modelling of switching power converters, Special Issue on Hybrid Systems

    NARCIS (Netherlands)

    Escobar, Gerardo; van der Schaft, Arjan; Ortega, Romeo

    1999-01-01

    In this paper we show how, using the Hamiltonian formalism, we can systematically derive mathematical models that describe the behaviour of a large class of switching power converters, including the “Boost”, “Buck”, “Buck-Boost”, “ uk” and “Flyback” converters. We follow the approach proposed by van

  14. Boosted PWM open loop control of hydraulic proportional valves

    International Nuclear Information System (INIS)

    Amirante, R.; Innone, A.; Catalano, L.A.

    2008-01-01

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots

  15. Boosted PWM open loop control of hydraulic proportional valves

    Energy Technology Data Exchange (ETDEWEB)

    Amirante, R.; Catalano, L.A. [Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Via Re David 200, 70125 Bari (Italy); Innone, A. [Universita degli Studi di Foggia, via Napoli, 25 Foggia (Italy)

    2008-08-15

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots. (author)

  16. High flexibility and low cost digital implementation for modern PWM strategies

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Kerekes, Tamas

    2011-01-01

    like AZSPWM, NSPWM, or ACRPWM. By using a conventional PWM unit from a microcontroller, these modern modulation techniques are often difficult, or even impossible, to implement. The proposed method can be used to implement PWM strategies even for those microcontrollers which are not equipped...

  17. Large Signal Model of a Four-quadrant AC to DC Converter for Accelerator Magnets

    CERN Document Server

    De la Calle, R; Rinaldi, L; Völker, F V

    2001-01-01

    This paper presents the large signal model of a four-quadrant AC to DC converter, which is expected to be used in the area of particle accelerators. The system’s first stage is composed of a three-phase boost PWM (Pulse Width Modulated) rectifier with DSP (Digital Signal Processing) based power factor correction (PFC) and output voltage regulation. The second stage is a full-bridge PWM inverter that allows fast four-quadrant operation. The structure is fully reversible, and an additional resistance (brake chopper) is not needed to dissipate the energy when the beam deflection magnet acts as generator.

  18. A three-port direct current converter

    DEFF Research Database (Denmark)

    2016-01-01

    circuit comprises a connection between the at least one input direct current source and the at least one storage battery, the primary side circuit configured for operating as a buck converter; a second magnetic component serially coupled to the first single magnetic component, wherein the first and second...... magnetic components are configured to perform a voltage step-up, wherein the secondary side circuit comprises a connection between the at least one storage battery and at least one load, the secondary side configured for operating as a tapped boost converter; wherein the three-port direct current converter......The three-port direct current converter comprising: at least one input direct current source; at least one storage battery; a primary side circuit; a secondary side circuit; a first single magnetic component shared by the primary side circuit and the secondary side circuit, wherein the primary side...

  19. A Zero-Voltage Switching Control Strategy for Dual Half-Bridge Cascaded Three-Level DC/DC Converter with Balanced Capacitor Voltages

    DEFF Research Database (Denmark)

    Liu, Dong; Wang, Yanbo; Chen, Zhe

    2017-01-01

    The input capacitor's voltages are unbalanced under the conventional control strategy in a dual half-bridge cascaded three-level (TL) DC/DC converter, which would affect the high voltage stresses on the capacitors. This paper proposes a pulse-wide modulation (PWM) strategy with two working modes...... for the dual half-bridge cascaded TL DC/DC converter, which can realize the zero-voltage switching (ZVS). More significantly, a capacitor voltage balance control is proposed by alternating the two working modes of the proposed ZVS PWM strategy, which can eliminate the voltage unbalance on the four input...... capacitors. Therefore, the proposed control strategy can improve the converter's performances in: 1) reducing the switching losses and noises of the power switches; and 2) reducing the voltage stresses on the input capacitors. Finally, the simulation results are conducted to verify the proposed control...

  20. A PWM strategy for acoustic noise reduction for grid-connected single-phase inverters

    Energy Technology Data Exchange (ETDEWEB)

    Shao, R.; Guo, Z.; Chang, L. [New Brunswick Univ., Fredericton, NB (Canada). Dept. of Electrical and Computer Engineering

    2006-07-01

    This paper presented a newly proposed and improved pulse width modulation (PWM) strategy for grid-connected single-phase inverters. Small distributed generators using energy from renewable resources such as PV and wind systems typically use grid-connected single-phase inverters as voltage source inverters for good acoustic performance. PWM is generally applied in these inverters in order to achieve good waveforms of output current as required by interconnection standards. In routine simultaneous switching PWM methods, the current ripples through the inverter output filter inductor are at the carrier switching frequency, which is one of the major causes for inverter acoustic noise. The new PWM strategy effectively alleviates acoustic noise and improves output power quality. It is based on the principle of evenly splitting the switching of Insulated Gate Bipolar Transistors (IGBT) in each switching cycle among all IGBTs of the full bridge, thereby using a non-simultaneous mode of PWM which doubles the output current ripple frequency. This increases the inductor current ripple frequency to twice the carrier frequency. It is therefore possible to increase the current ripple frequency, or noise frequency into the range of ultrasonic which is inaudible to the human ear, without increasing the inverter's switching frequency to which the inverter's switching loss is proportional. In addition, this new PWM scheme can reduce the output current harmonics distortion and dc link current ripples. As such, lower capacitance in dc link capacitors and lower inductance of output inductor are needed. The improved PWM scheme was verified in a 3 kW grid-connected single-phase inverter. It was shown that the PWM strategy can be readily implemented with a digital signal processing microcontroller. 8 refs., 11 figs.

  1. High-Voltage DC-DC Converter Topology for PV Energy Utilization - Investigation and Implementation

    DEFF Research Database (Denmark)

    Sanjeevikumar, Padmanaban; Blaabjerg, Frede; Wheeler, Patrick

    2017-01-01

    This paper exploited the utilization of photovoltaic (PV) energy system with high-voltage (HV) output DC-DC converter. Classical boost converters are used for both renewable energy integration and HV applications, but limited by reducing output/efficiency in performance. Moreover, as parasitic...... elements suppress the power transfer ratio, converter needs to maximize the PV energy utilization. This investigation study focused to include additional parasitic elements (voltage-lift technique) to a standard DC-DC buck converter and to overcome all the above drawbacks to maximize the PV power...

  2. Growth Performance of Red Sokoto Bucks Fed Inclusion levels of ...

    African Journals Online (AJOL)

    This study was carried out to evaluate the growth performance of red Sokoto bucks fed two (2) inclusion levels of rawwater soaked and lime soaked Hibiscus sabdariffa seeds in rice offal based diets. A total of twenty one (21) red Sokoto bucks were randomly allotted into seven treatments with three (3) bucks per group while ...

  3. Improved Kayaking Ergometer Using a Switch-mode Converter Driven Alternator

    DEFF Research Database (Denmark)

    Cornaby, Chris; Friberg, Jeppe; Søndergaard, Nikolaj B.

    2016-01-01

    described. A synchronous-rectified buck converter has been designed to control the current through the rotor and, by extension, the mechanical resistance felt by the oarsman. The circuit was designed to function with a 12V car battery as a supply. Necessary specifications for efficiency and output stability...

  4. Position control of an electro-pneumatic system based on PWM technique and FLC.

    Science.gov (United States)

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Liquid Nitrogen Temperature Operation of a Switching Power Converter

    Science.gov (United States)

    Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Myers, Ira T.

    1995-01-01

    The performance of a 42/28 V, 175 W, 50 kHz pulse-width modulated buck dc/dc switching power converter at liquid nitrogen temperature (LNT) is compared with room temperature operation. The power circuit as well as the control circuit of the converter, designed with commercially available components, were operated at LNT and resulted in a slight improvement in converter efficiency. The improvement in power MOSFET operation was offset by deteriorating performance of the output diode rectifier at LNT. Performance of the converter could be further improved at low temperatures by using only power MOSFET's as switches. The use of a resonant topology will further improve the circuit performance by reducing the switching noise and loss.

  6. Soft switching buck-boost converter for photovoltaic power generation; Taiyoko hatsuden no tame no soft switching shokoatsu converter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H. [Kyungnam University (Korea, Republic of)

    1996-10-27

    A soft switching method with small switching loss was proposed for the purpose of increasing the efficiency of a DC-DC boost converter which converted a DC current generated by solar cells to a variable DC current. Existing current converters are supplemented by using a snubber circuit around the switch so as to protect the switch by a hard switching action. However, with an increase of the output current, snubber loss is increased, reducing the efficiency. In order to solve this problem, the partial resonant switch method was applied to the converter; with this method of partially forming a resonant circuit only at the time of turning on/off of the switch, the switching loss was reduced through the soft switching, thereby making the proposed converter operate with high efficiency. Moreover, the resonant element of the partial resonant circuit using a snubber condenser, the energy accumulated in the condenser was regenerated on the power supply side without loss of snubber. With the regenerated energy, the proposed converter was provided with a smaller ratio of switching to use than the conventional converter. 4 refs., 7 figs., 1 tab.

  7. PEMODELAN DAN SIMULASI TOPOLOGI SINGLE ENDED PRIMARY INDUCTOR CONVERTER (SEPIC) UNTUK MINI 3 PLUS WIND TURBINE

    OpenAIRE

    Prasetiyo, Ryan; Maulana, Dwindra Wilham; Panatarani, Camellia; Joni, I Made

    2016-01-01

    In order to have a DC-DC buck boost converter with performances as desired specifications, the design process was performed by developing a model and simulation. The purpose of this research was to design a converter applied for a MINI 3 plus Wind Turbine. The converter topology was designed with Single Ended Primary Inductor Converter (SEPIC) using  a Continuous Conduction Mode (CCM). The output specifications of converter are input voltage 60 V, input current 7,5 A, output voltage 25 V...

  8. Performance optimization of a photovoltaic chain conversion by the PWM control

    Science.gov (United States)

    Rezoug, M. R.; Chenni, R.

    2017-02-01

    The interest of the research technique of maximum power point tracking, exposed by this article, lays in the fact of work instantly on the real characteristic of the photovoltaic module. This work is based on instantaneous measurements of its terminals' current & voltage as well as the exploitation of the characteristic "Power - Duty Cycle" to define rapidly the Duty cycle in which power reaches its maximum value. To ensure instantaneous tracking of the point of maximum power, we use "DC/DC Converter" based on "Pulse Wave Modulation's (PWM) Command" controlled by an algorithm implanted in a microcontroller's memory. This algorithm responds to the quick changes in climate (sunlight and temperature). To identify the control parameters "VPV & IPV" at any change in operating conditions, sensors are projected. this algorithm applied to the Duty cycle of the static converter enables the control of power supplied by the photovoltaic generator thanks to oscillatory movement around the MPP. Our article highlights the importance of this technique which lays in its simplicity and performance in changing climatic conditions. This efficiency is confirmed by experimental tests and this technique will improve its predecessors.

  9. A dual-path, current-sensing resistor-free boost LED driver with fast PWM dimming

    International Nuclear Information System (INIS)

    Zhou Minchao; Lü Danzhu; Cheng Lin; Hong Zhiliang; Liu, Bill Yang

    2013-01-01

    A boost LED driver featuring a high PWM dimming ratio and optimized efficiency is presented. This LED driver, which has a low dropout voltage and is able to drive 3–7 LEDs in series with constant output current and fast PWM dimming, provides an alternative technique for brightness adjustment. A dual-path control scheme with automatic switching and state maintenance is proposed. Meanwhile, a cascode current mirror structure is applied with the output transistor multiplexed as an LED PWM dimming transistor. Implemented in 0.5 μm 25 V BCD process, the measurement results show that a voltage conversion range of 5 V input to 6–24 V output with constant output current is obtained. With automatically switching dual-path control and an optimized current mirror, the response time during PWM dimming is reduced to as low as 240 ns and the efficiency keeps above 89% over a wide PWM dimming ratio - 250 mA output current. (semiconductor integrated circuits)

  10. Development of a Novel Bidirectional DC/DC Converter Topology with High Voltage Conversion Ratio for Electric Vehicles and DC-Microgrids

    Directory of Open Access Journals (Sweden)

    Ching-Ming Lai

    2016-05-01

    Full Text Available The main objective of this paper was to study a bidirectional direct current to direct current converter (BDC topology with a high voltage conversion ratio for electric vehicle (EV batteries connected to a dc-microgrid system. In this study, an unregulated level converter (ULC cascaded with a two-phase interleaved buck-boost charge-pump converter (IBCPC is introduced to achieve a high conversion ratio with a simpler control circuit. In discharge state, the topology acts as a two-stage voltage-doubler boost converter to achieve high step-up conversion ratio (48 V to 385 V. In charge state, the converter acts as two cascaded voltage-divider buck converters to achieve high voltage step-down conversion ratio (385 V to 48 V. The features, operation principles, steady-state analysis, simulation and experimental results are made to verify the performance of the studied novel BDC. Finally, a 500 W rating prototype system is constructed for verifying the validity of the operation principle. Experimental results show that highest efficiencies of 96% and 95% can be achieved, respectively, in charge and discharge states.

  11. New DC/DC High Step Up Isolated Converter with ZVS

    Directory of Open Access Journals (Sweden)

    Ehsan Movahedi

    2014-10-01

    Full Text Available In this paper we presents a soft switch sepic, flyback converter. At first the converter have hard switching in main switch and completely analysis then added auxiliary circuit for soft switching Auxiliary circuit in the converter is not only soft switching condition for the main switch but also prevents the spike voltage across the main switch when turned off that because leakage inductance. Therefore, the proposed converter efficiency in comparison with the previous converters increased and voltage stress on the main switch is reduced. Also the auxiliary switch in the converter have soft switching and thereby decrese losses. this converter Control with pwm.These converter have higher efficiency than the similar converters and the cost is low. Auxiliary circuit in the converter is not only soft switching condition for the main switch but also prevents the spike voltage across the main switch when turned off that because leakage inductance. Therefore, the proposed converter efficiency in comparison with the previous converters increased and voltage stress on the main switch is reduced.

  12. Discrete/PWM Ballast-Resistor Controller

    Science.gov (United States)

    King, Roger J.

    1994-01-01

    Circuit offers low switching loss and automatic compensation for failure of ballast resistor. Discrete/PWM ballast-resistor controller improved shunt voltage-regulator circuit designed to supply power from high-resistance source to low-impedance bus. Provides both coarse discrete voltage levels (by switching of ballast resistors) and continuous fine control of voltage via pulse-width modulation.

  13. Ram and Buck Breeding Soundness Examination

    Directory of Open Access Journals (Sweden)

    Ahmed TIBARY

    2018-06-01

    Full Text Available Male breeding soundness examination (BSE is an important component of sheep and goat farming. BSE is best performed 2 months before the breeding season and is based on clinical and physical examination as well as sperm abnormalities detection. Rams are classified based on physical examination and semen evaluation finding in one of 4 categories: Unsatisfactory, questionable, satisfactory, and excellent. The satisfactory rams will achieve good reproductive performance if joined to ewes at a ratio of 1:50 for 60 days. However exceptional rams are expected to achieve good reproductive performance at a ratio of 1 ram to 100 ewes. For Buck, scrotal circumference should be at least 25 cm for breeds weighing more than 40 kg. Buck is deemed satisfactory breeder if he passes the physical examination, and has an ejaculate with at least 50% progressively motile spermatozoa and less than 30% total sperm abnormalities. This paper reviews factors affecting fertility, sperm production and quality as well as libido and mating ability in the ram. Details of genital examination and semen evaluation and interpretation of results are discussed. Classification of rams according to their reproductive potential is presented. Specific recommendations, when available for the buck, are highlighted. The main genital diseases are presented. The most frequent culling reason for ram is epididymitis due to Brucella ovis. Systematic culling of rams with epididymitis improves flock lambing rates by 10 to 15%. Overall, the examination of the reproductive capacity in the ram and the buck is an important tool for improvement of flocks/herds fertility and prevention of contagious or hereditary diseases.

  14. Performance analysis of samarium cobalt P.M. synchronous motor fed from PWM inverters

    International Nuclear Information System (INIS)

    Rahman, M.A.; Choudhury, M.A.

    1985-01-01

    This paper presents an analysis and performance of samarium cobalt permanent magnet (P.M.) synchronous motors fed from two types of voltage source pulse width modulated (PWM) inverters. The analysis and test results on the steady state performance of a P.M. motor fed from PWM inverters are presented. PWM inverters are used in variable voltage variable frequency applications to avoid a double conversion process of ordinary inverters. In drives, they are used for voltage and speed regulation of motors. Use of modulation technique in inverters also allow to eliminate or minimize selected harmonics from the inverter output voltage

  15. Simple Digital Control of a Two-Stage PFC Converter Using DSPIC30F Microprocessor

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2010-01-01

    The use of dsPIC digital signal controllers (DSC) in Switch Mode Power Supply (SMPS) applications opens new perspectives for cheap and flexible digital control solutions. This paper presents the digital control of a two stage power factor corrector (PFC) converter. The PFC circuit is designed...... and built for 70W rated output power. Average current mode control for boost converter and current programmed control for forward converter are implemented on a dsPIC30F1010. Pulse Width Modulation (PWM) technique is used to drive the switching MOSFETs. Results show that digital solutions with ds...

  16. Discontinuous PWM Modulation Strategy with Circuit-Level Decoupling Concept of Three-Level Neutral-Point Clamped (NPC) Inverter

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2013-01-01

    inverters, but also reduces the switching loss of the inverter along with an inherent neutral point (NP) voltage control. Based on a circuit-level decoupling concept, the NPC inverter can be decoupled into two three-level Buck converters in every defined operating section, and thereby the controller design...... can be reduced by one third. In order to explain the operation of this topology properly, the decoupling principle including the driving signal synthesis and the NP potential variation are analyzed in detail in this paper. Finally the viability and performance of the proposed modulation scheme...

  17. Apparent permeability of electrical steel under PWM magnetisation

    International Nuclear Information System (INIS)

    Moses, A.J.; Leicht, J.; Anderson, P.

    2006-01-01

    In recent years much attention has been paid to material performance under pulse width modulation (PWM) excitation conditions, which is of increasing importance to motor applications particularly in energy efficient variable speed drive systems. It is well known that in general, losses increase significantly with reducing modulation index, the increase depending on parameters such as silicon contents, thickness and grain size. The effect of the PWM waveform on permeability has attracted little attention until now. So in this paper its influence on the permeability of electrical steel is analysed and characterised. A prediction approach based on the permeability under sine wave excitation and total harmonic distortion is introduced which results in errors below 10% for non-electrical steel at 1.5 T

  18. Bridgeless SEPIC PFC Converter for Multistring LED Driver

    Science.gov (United States)

    Jha, Aman; Singh, Bhim

    2018-05-01

    This paper deals with Power Factor Correction (PFC) in Low Voltage High Current (LVHC) multi-string light emitting diode (LED) using a bridgeless (BL) single ended primary inductance converter (SEPIC). This application is designed for large area LED lighting with illumination control. A multi-mode LED dimming technique is used for the lighting control. The BL-SEPIC PFC converter is used as a load emulator for high power factor. The regulated low voltage from flyback converter is a source power to the synchronous buck converters for multi-string LED driver and forced cooling system for LED junction. The BL-SEPIC PFC converter inductor design is based on Discontinuous Inductor Current Modes (DICM) which provides good PFC at low cost. Test results are found quite satisfactory for universal input AC (90-265 V). There is significant improvement in the power factor and input current Total Harmonic Distortion (THD) with good margin of harmonic limits for lighting IEC 61000-3-2 Class C.

  19. Predictive digital peak current mode controller for DC-DC converters capable of operating over the full 0-100% duty cycle range

    DEFF Research Database (Denmark)

    Andersen, Karsten Holm; Nymand, Morten

    2017-01-01

    ) and discontinuous conduction mode (DCM) and supports high switching frequencies even with low cost A/D converters. The proposed controller is implemented in a Field Programmable Gate Array (FPGA) to control a 450 W buck converter and the experimental results verify the controller's capability to operate in the full...

  20. Physiological response of rabbit bucks to prolonged feeding of ...

    African Journals Online (AJOL)

    Sixty-four (64) weanling rabbit bucks, 5 to 6 weeks old, were involved in a 2 x 4 factorial experiment to evaluate the effects of prolonged feeding of cottonseed cake (CSC) – based diets with or without vitamin E supplementation on the physiological response of the bucks. There were eight treatment combinations comprising ...

  1. Theoretical assessment of the maximum power point tracking efficiency of photovoltaic facilities with different converter topologies

    Energy Technology Data Exchange (ETDEWEB)

    Enrique, J.M.; Duran, E.; Andujar, J.M. [Departamento de Ingenieria Electronica, de Sistemas Informaticos y Automatica, Universidad de Huelva (Spain); Sidrach-de-Cardona, M. [Departamento de Fisica Aplicada, II, Universidad de Malaga (Spain)

    2007-01-15

    The operating point of a photovoltaic generator that is connected to a load is determined by the intersection point of its characteristic curves. In general, this point is not the same as the generator's maximum power point. This difference means losses in the system performance. DC/DC converters together with maximum power point tracking systems (MPPT) are used to avoid these losses. Different algorithms have been proposed for maximum power point tracking. Nevertheless, the choice of the configuration of the right converter has not been studied so widely, although this choice, as demonstrated in this work, has an important influence in the optimum performance of the photovoltaic system. In this article, we conduct a study of the three basic topologies of DC/DC converters with resistive load connected to photovoltaic modules. This article demonstrates that there is a limitation in the system's performance according to the type of converter used. Two fundamental conclusions are derived from this study: (1) the buck-boost DC/DC converter topology is the only one which allows the follow-up of the PV module maximum power point regardless of temperature, irradiance and connected load and (2) the connection of a buck-boost DC/DC converter in a photovoltaic facility to the panel output could be a good practice to improve performance. (author)

  2. PWM pulse pattern optimization method using carrier frequency modulation. Carrier shuhasu hencho ni yoru PWM pulse pattern saitekikaho

    Energy Technology Data Exchange (ETDEWEB)

    Iwaji, Y.; Fukuda, S. (Hokkaido University, Sapporo (Japan))

    1991-07-15

    Sinusoidal inverters are getting more widely used keeping pace with the development of semiconductor switching elements. This paper discusses optimizing a PWM pulse pattern at an inverter output to drive an induction motor, proposes methods for improving distortion and torque ripples using a carrier frequency modulation (CFM), and describes a method for realizing the improvement through use of a single-chip microcomputer. The method defines evaluation parameters corresponding to the distortion and torque ripples, and optimizes the CFM depth to the parameters. The PWM pulse pattern has its voltage vector and time width so selected that the time integrated space vector of a three-phase voltage approaches a circular locus. Furthermore, the carrier frequency, that is the sampling frequency of the inverter, is also adjusted so that the above evaluation parameters are minimized. The addition of a new variable called the frequency modulation provides freedom in selecting an output characteristic as called for by the purpose. 12 refs., 18 figs.

  3. Testicular Morphometry and Sperm Quality of Rabbit Bucks Fed ...

    African Journals Online (AJOL)

    Twenty rabbit bucks of mixed breeds, aged four to five weeks which weighed between 627.4g to 631.5g were used to evaluate the effect of Moringa oleifera leaf meal (MOLM) on testicular morphometry and sperm quality. Five bucks were randomly assigned to each of the four diets containing MOLM at 0%. 5%, 10% and ...

  4. Practical Design Guidelines of qZSI Based Step-Up DC/DC Converter

    Science.gov (United States)

    Zakis, Janis; Vinnikov, Dmitri; Roasto, Indrek; Jalakas, Tanel

    2010-01-01

    This paper presents some design guidelines for a new voltage fed step-up DC/DC isolated converter. The most significant advantage of proposed converter is voltage buck-boost operation on single stage. The most promising application for proposed converter is in the field of distributed power generation e.g. fuel cells or photovoltaic. The most sensitive issues - such as power losses caused by high currents in the input side of converter and high transient overvoltages across the inverter bridge caused by stray inductances were discussed and solved. The proposals and recommendations to overcome these issues are given in the paper. The Selection and design guidelines of converter elements are proposed and explained. The prototype of proposed converter was built and experimentally tested. Some results are presented and evaluated.

  5. PWM control of current source type six-phase inverter with improved waveforms by coupling reactor; Ketsugo reactor ni yori hakei kaizen sareta denryugata rokuso inverter no PWM seigyo

    Energy Technology Data Exchange (ETDEWEB)

    Inami, K.; Danjo, M.; Kondo, Y.; Yamada, M. [Niihama Technical College, Ehime (Japan); Toki, K. [Shikoku Electric Power Co., Inc., Kagawa (Japan); Heike, J. [Shikoku Instrumentation Co. Ltd., Kagawa (Japan)

    1998-10-01

    A PWM method has been applied to a high capacity six phase current source inverter system in order to obtain sinusoidal output voltage and current. In this system, the three-phase coupling reactor is connected between the inverter output and an induction motor used as a load. Then the reactor eliminates harmonic components included in the inverter output current except 12k {+-} 1 (k=1,2,3)th order. As a result, the distortion factor of the inverter output current decreases. But the resonant circuit is composed of the capacitance of filter capacitor and the induction motor leakage inductance. Then the resonance current is superimposed on the induction motor phase currents. To solve this problem, the optimal PWM pattern is derived, so that the resonant current becomes very small. The order of the resonant frequency component of the induction motor phase current depend on the inverter frequency. Then total inverter frequency range is divided into several areas. The optimal PWM pattern is derived in each areas. As a result, the use of each optimal PWM pattern allows us to drive the induction motor, over a wide range of speed, under the condition of small distortion factor of phase currents. 5 refs., 10 figs., 1 tab.

  6. EVALUATION OF VARIOUS UNIPOLAR MULTICARRIER PWM STRATEGIES FOR FIVE LEVEL FLYING CAPACITOR INVERTER

    Directory of Open Access Journals (Sweden)

    B. SHANTHI

    2012-06-01

    Full Text Available This paper presents the comparison of unipolar multicarrier Pulse Width Modulation (PWM techniques for the Flying Capacitor Multi Level Inverter (FCMLI. Due to switch combination redundancies, there are certain degrees of freedom to generate the five level AC output voltage. This paper presents the use of Control Freedom Degree (CFD combination. The effectiveness of the PWM strategies developed using CFD are demonstrated by simulation and experimentation. The results indicate that the multilevel inverter triggered by the developed USHPWM strategy exhibits reduced harmonics. PWM strategies developed are implemented in real time using dSPACE/Real Time Interface (RTI. The simulation and experimental output closely match with each other validating the strategies presented.

  7. A Novel Application of Zero-Current-Switching Quasiresonant Buck Converter for Battery Chargers

    OpenAIRE

    Kuo-Kuang Chen

    2011-01-01

    The main purpose of this paper is to develop a novel application of a resonant switch converter for battery chargers. A zero-current-switching (ZCS) converter with a quasiresonant converter (QRC) was used as the main structure. The proposed ZCS dc–dc battery charger has a straightforward structure, low cost, easy control, and high efficiency. The operating principles and design procedure of the proposed charger are thoroughly analyzed. The optimal values of the resonant components are compute...

  8. ABNORMAL AND TRANSIENT MODES OF THE CONVERTER BOOSTER TYPE FOR DC TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    Yu. P. Goncharov

    2008-12-01

    Full Text Available The results of analytical research and computer design of the anomalous, steady-state and transitional modes related to the resonance in the input filter of voltage added converter based on IGBT with the PWM are presented. The ways of resonance removal by both the control means and the power blocks, combined with the overvoltage protection, are offered.

  9. Three-Level AC-DC-AC Z-Source Converter Using Reduced Passive Component Count

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Gao, Feng; Tan, Pee-Chin

    2009-01-01

    This paper presents a three-level ac-dc-ac Z-source converter with output voltage buck-boost capability. The converter is implemented by connecting a low-cost front-end diode rectifier to a neutral-point-clamped inverter through a single X-shaped LC impedance network. The inverter is controlled...... to switch with a three-level output voltage, where the middle neutral potential is uniquely tapped from the star-point of a wye-connected capacitive filter placed before the front-end diode rectifier for input current filtering. Through careful control, the resulting converter can produce the correct volt...

  10. EFFECT OF MUCUNA (Mucuna pruriens ON SPERMIOGRAMS OF WEST AFRICAN DWARF BUCKS

    Directory of Open Access Journals (Sweden)

    James Olamitibo Daramola

    2015-08-01

    Full Text Available The study was carried out to investigate the potential effect of Mucuna pruriens seed powder on spermiograms of West African Dwarf bucks (WAD. Twenty bucks were randomly assigned to five treatments consisting of four animals each receiving 0, 25, 50, 75, 100mg/Bw of Mucuna pruriens seed powder administered via oral route for 30 days consecutively. Following treatment, spermiograms of the animals were determined. The results showed that exposure of bucks to Mucuna pruriens powder led to a significant increase in weight gain, scrotal width, scrotal circumference, testicular weight, gonadosomatic index, sperm motility and testicular parenchyma of animals compared to the control and the improvement in these parameters was much pronounced in bucks that received 75mg Mucuna pruriens seed powder (P<0.05. Higher (P<0.05 sperm concentration was observed in 100mg inclusion of Mucuna pruriens seed powder compared to other treatments. The results showed a decline (P<0.05 in the level of testosterone with increasing level of Mucuna pruriens seed powder administration. The findings showed that oral administration of Mucuna pruriens seed powder to the bucks for 30 days resulted in improved testicular measurements and sperm quality without any adverse effect on structure of reproductive physiology of the bucks.

  11. Topological Design and Modulation Strategy for Buck-Boost Three-Level Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus

    2009-01-01

    To date, designed topologies for dc-ac inversion with both voltage buck and boost capabilities are mainly focused on two-level circuitries with extensions to three-level possibilities left nearly unexplored. Contributing to this area of research, this paper presents the design of a number of viable...... can perform distinct five-level line voltage and three-level phase voltage switching by simply controlling the active switches located in the designed voltage boost section of the circuits. As a cost saving option, one active switch can further be removed from the voltage boost section of the circuits...... buck-boost threelevel inverters that can also support bidirectional power conversion. The proposed front-end circuitry is developed from the C´ ukderived buck-boost two-level inverter, and by using the "alternative phase opposition disposition" modulation scheme, the buck-boost three-level inverters...

  12. Passivity-Based Control by Series/Parallel Damping of Single-Phase PWM Voltage Source Converter

    NARCIS (Netherlands)

    del Puerto Flores, Dunstano; Scherpen, Jacqueline; Liserre, Marco; de Vries, Martijn M. J.; Kransse, Marco J.; Monopoli, Vito Giuseppe

    This paper describes a detailed design procedure for passivity-based controllers developed using the Brayton-Moser (BM) framework. Several passivity-based feedback designs are presented for the voltage-source converter, specifically for the H-bridge converter, since nowadays it is one of the

  13. Application research of power allocation based on Buck circuit in DC microgrid

    Directory of Open Access Journals (Sweden)

    Wang Zihao

    2017-01-01

    Full Text Available In a traditional DC microgrid, the power sharing control strategy has been always used in the distributed power converters, resulting in not making outer power allocation arbitrarily. In order to solve the power output allocation problem of wind power in DC microgrid, the intelligent Buck circuit based on PI algorithm and the load current feed-forward method was used to realize the arbitrary regulation of the output power of the wind power in the DC microgrid system. Compared with traditional distributed generators power-sharing method, the simulation and experimental results show the proposed method can realize arbitrary power outputting from distributed generators. Finally, the simulation and experimental results prove the validity and effectiveness of the control method.

  14. EMC Specific Problems of Frequency Converters Used at Interlocking Device

    Directory of Open Access Journals (Sweden)

    J. Novak

    2009-12-01

    Full Text Available The paper deals with problems of electromagnetic compatibility (EMC of frequency control drive of electromotive switch actuator of railway switch. The frequency converter with Pulse Width Modulation (PWM and the output sinus filter are used for feeding of the asynchronous motor of the switch actuator. This drive is operated in an insulated system of feeding voltages. The drive is fed by a frequency converter with an unshielded cable with length up to 1.2 km. The EMC problems occurring at development and operating of the drive are analyzed in this paper. The used solution of these problems and experience with EMC of the given system from real operation are described in this paper as well.

  15. A Single Phase to Three Phase PFC Half-Bridge Converter Using BLDC Drive with SPWM Technique.

    OpenAIRE

    Srinu Duvvada; Manmadha Kumar B

    2014-01-01

    In this paper, a buck half-bridge DC-DC converter is used as a single-stage power factor correction (PFC) converter for feeding a voltage source inverter (VSI) based permanent magnet brushless DC motor (BLDC) drive. The front end of this PFC converter is a diode bridge rectifier (DBR) fed from single-phase AC mains. The BLDC is used to drive a compressor load of an air conditioner through a three-phase VSI fed from a controlled DC link voltage. The speed of the compressor is controlled to ach...

  16. Control Strategies for Trap Filter Interfaced Three-Phase Grid Connected Converters

    DEFF Research Database (Denmark)

    Min, Huang

    In order to utilize renewable energy systems power electronics are needed to convert the energy to grid. The AC-DC and DC-AC power conversion are dominant in wind power system and photovoltaic system. However, the use of PWM scheme introduces undesirable harmonics. In order to enhance the grid...... damping in order to stabilize the whole system with resonance issue. LC trap filter application for current source converters to reduce the size of the filter and get a higher power factor....... integration of the renewable energy systems, the filter plays an important role. Even though this topic has already been widely studied, there are many optimizations and problems should be solved. How to design a filter for grid-connected converters in distributed generation system to get a lower loss...

  17. Buck supplies output voltage ripple reduction using fuzzy control

    Directory of Open Access Journals (Sweden)

    Nicu BIZON

    2007-12-01

    Full Text Available Using the PWM control for switching power supplies the peaks EMI noise appear at the switching frequency and its harmonics. Using randomize or chaotic PWM control techniques in these systems the power spectrum is spread out in all frequencies band spectral emissions, but with a bigger ripple in the output voltage. The proposed nonlinear feedback control method, which induces chaos, is based by fuzzy rules that minimize the output voltage ripple. The feasibility and effectiveness of this relative simple method is shown by simulation. A comparison with the previous control method is included, too.

  18. EFFECT OF MUCUNA (Mucuna pruriens) ON SPERMIOGRAMS OF WEST AFRICAN DWARF BUCKS

    OpenAIRE

    James Olamitibo Daramola; John Adesanya Abiona; Olusiji Frederick Smith; Olubunkola Ajike Isah; Olusiji Sunday Sowande; Moshood Olajire Olaniyi; Jimoh Alao Olanite

    2015-01-01

    The study was carried out to investigate the potential effect of Mucuna pruriens seed powder on spermiograms of West African Dwarf bucks (WAD). Twenty bucks were randomly assigned to five treatments consisting of four animals each receiving 0, 25, 50, 75, 100mg/Bw of Mucuna pruriens seed powder administered via oral route for 30 days consecutively. Following treatment, spermiograms of the animals were determined. The results showed that exposure of bucks to Mucuna pruriens powder led to a sig...

  19. Assessment of goat breed improvement through distribution of beetal bucks in rainfed pothwar, Punjab

    International Nuclear Information System (INIS)

    Akmal, N.; Shah, H.; Niazi, N.

    2010-01-01

    The present paper is based on the assessment of goat breed improvement intervention through supply of 65 Beetal bucks in rainfed Pothwar. To judge short term impact and assessment, a survey was carried out of both buck holder and non-holder beneficiaries in six project tehsils, after one year of buck distribution. Data were collected from a sample of 38 buck holders and 31 beneficiary farmers using a structured pretested questionnaire. The main influencing factor in keeping bucks was goat breed improvement. All the sample respondents were convinced of the benefits of crosses with Beetal buck and reported that the offsprings Beetal were of higher body weight (40% higher), good looking and well built. Regarding the suitability of Beetal with fodder and forage in the area, majority of the farmers (73%) considered it more suitable. There was a price difference of Rs. 1277 for male kids and Rs. 697 for female kids of the same age than the kids from local buck crosses. The farmers believed that the price difference was not only due to the higher weight but a better look and better structure of the Beetal goat. Farming community showed keen interest in using this intervention on a regular basis. (author)

  20. High benefits approach for electrical energy conversion in electric vehicles from DC to PWM-AC without any generated harmonic

    International Nuclear Information System (INIS)

    Fathabadi, Hassan

    2014-01-01

    Highlights: • Novel hybrid power source including AC feature for using in electric/hybrid vehicles. • Minimizing the energy loss in electric/hybrid vehicles by using the proposed system. • Suitable AC wave form for braking/accelerating purposes in electric/hybrid vehicles. • A novelty is that the harmonic generated by the added AC feature is really zero. • Another novelty is the capability of choosing arbitrary frequency for AC feature. - Abstract: This paper presents a novel hybrid power source, including a Li-ion battery together with an interface, which generates simultaneously electrical energy with the forms of both DC and AC for electric vehicles. A novel and high benefits approach is applied to convert the electrical energy of the Li-ion battery from DC form to single-phase symmetric pulse-width modulation (PWM)-AC form. Harmonic generation is one of the important problems when electrical energy is converted from DC to AC but there are not any generated harmonic during the DC/AC conversion using the proposed technique. The proposed system will be widely used in electric/hybrid vehicles because it has many benefits. Minimizing the energy loss (saving energy), no generated harmonic (it is really zero), the capability of arbitrary/necessary frequency selection for output AC voltage and the ability of long distance energy transmission are some novelties and advantages of the proposed system. The proposed hybrid power source including DC/AC PWM inverter is simulated in Proteus 6 software environment and a laboratory-based prototype of the hybrid power source is constructed to validate the theoretical and simulation results. Simulation and experimental results are presented to prove the superiority of the proposed hybrid power supply

  1. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    OpenAIRE

    Md. Rajibur Rahaman Khan; Shin-Won Kang

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal?s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The...

  2. Isolated PDM and PWM DC-AC SICAMs[Pulse Density Modulated; Pulse Width Modulated

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report a class of isolated PDM and PWM DC-AC SICAMs is described, which introduce the audio reference only in the output stage. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitor. Isolation from the AC mains is achieved using a high frequency (HF) transformer, receiving the HF voltage pulses from the input 'inverter' stage and transferring them to the output 'rectifier+inverter' stage, which can use either PDM or PWM. The latter stage is then interfaced to the load using an output low-pass filter. Each of the dedicated stages is discussed in detail. Measurements on the master/slave PWM DC-AC SICAM prototype are presented to help benchmarking the performance of this class of SICAMs and identify the advantages and drawbacks. (au)

  3. The 120V 20A PWM switch for applications in high power distribution

    Science.gov (United States)

    Borelli, V.; Nimal, W.

    1989-08-01

    A 20A/120VDC (voltage direct current) PWM (Pulse Width Modulation) Solid State Power Controller (SSPC) developed under ESA contract to be used in the power distribution system of Columbus is described. The general characteristics are discussed and the project specification defined. The benefits of a PWM solution over a more conventional approach, for the specific application considered are presented. An introduction to the SSPC characteristics and a functional description are presented.

  4. Conference James F.Buckli

    CERN Multimedia

    Buckli,J

    1988-01-01

    L'association du personnel a le plaisir d'accueillir Mons. James F.Buckli, astronaute, né en 1947. Il a participé à la mission Space Lab D1 qui pour la première fois mettait 8 personnes sur orbite.L'ass.du pers. remercie aussi Gordon White(s) de la mission américaine d'avoir permis d'organiser cette conférence

  5. Multi-level cascaded DC/DC converters for PV applications

    Directory of Open Access Journals (Sweden)

    Ahmed A.A. Hafez

    2015-12-01

    Full Text Available A robust multi-level cascaded DC/DC system for Photovoltaic (PV application is advised in this article. There are three PV generators, each is coupled to a half-bridge buck cell. Each PV-generator–buck-converter channel is controlled such that maximum power is captured independently under different irradiation and temperature levels. The system operation under normal and abnormal conditions was comprehensively investigated. Internal Model Control (IMC technique was adopted for tuning the controllers. An elaborate switching modulation strategy was used to reduce the current ripple and inductor size, while maintaining high efficiency. Annotative, simple and robust remedial strategies were proposed to mitigate different anticipated faults. Comprehensive simulation results in Matlab environment were illustrated for corroborating the performance of the advised cascaded DC/DC system under normal/abnormal conditions. The proposed system enjoys the merits of independency, reduced volumetric dimensions and improved efficiency. Furthermore, the system is inherently fault-tolerant.

  6. The comparison of radiosensitivity of human lymphocytes stimulated with PHA Con A and PWM

    International Nuclear Information System (INIS)

    Geng Yongzhi; Su Liaoyuan

    1989-11-01

    The transformation, DNA strand breaks and its repair ability in human peripheral blood lymphocytes stimulated with PHA, Con A and PWM were respectively assessed following exposure to 60 Co gamma rays by 3 H-thymidine uptake and hydroxylapatite chromatography. It was showed the transformation of lymphocytes stimulated with PHA, Con A and PWM were suppressed by gamma rays and the dose-effect curves were biphase within the range of 0∼8 Gy. The lymphocytes stimulated with PWM was the most resistant to gamma rays. The extent of DNA strand breaks in lymphocytes induced by gamma rays was linearly related to the dose within the range of 0∼30 Gy and was identical in three kinds of lymphocytes. After post-irradiation incubation of 37 deg C, the DNA strand breaks could be repaired incompletely and after maxium repair the strand breaks were observed again. The repair ratio of strand breaks in the lymphocytes stimulated with PWM was the highest in the cells with three mitogens. The results showed that the difference of radiation effect on the transformation is probably related to the repair ability of DNA strand breaks

  7. The performance of the DC motor by the PID controlling PWM DC-DC boost converter

    OpenAIRE

    Can, Erol; Sayan, Hasan Hüseyin

    2017-01-01

    This paper presents the PID controlling direct current (DC) to the direct current boost converter feds DC motor which has a 3.68 kW and 240 V of DC voltage input on its characteristics. What is first formed is the boost converter mathematical model at the design stage. Secondly, a mathematical model of the DC motor is created so that the boost converter with the machine can be established and modeled at the Matlab Simulink. The PID controller is considered for arranging a pulse width modulati...

  8. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    , resulting in the natural balance of input current. For maintaining the normalized volt-sec average unchanged, the alternative phase opposition disposition (APOD) modulation scheme with typical gating signal mapping technique from voltage source inverter (VSI) to CSI can be assumed to control the five......This paper presents new five-level current source inverters (CSIs) with voltage/current buck-boost capability. Being different from the existing multilevel CSI, the proposed CSIs were first designed to regulate the flowing path of dc input current by controlling two additional active switches......-level buck-boost CSIs. Next by observing the hidden current charging path during inductive charging interval under APOD modulation, it is noted that the buck-boost five-level CSI can then be further modified with lesser active component without degrading output performance. To verify the theoretical findings...

  9. Embedded system based on PWM control of hydrogen generator with SEPIC converter

    Science.gov (United States)

    Fall, Cheikh; Setiawan, Eko; Habibi, Muhammad Afnan; Hodaka, Ichijo

    2017-09-01

    The objective of this paper is to design and to produce a micro electrical plant system based on fuel cell for teaching material-embedded systems in technical vocational training center. Based on this, the student can experience generating hydrogen by fuel cells, controlling the rate of hydrogen generation by the duty ration of single-ended primary-inductor converter(SEPIC), drawing the curve rate of hydrogen to duty ratio, generating electrical power by using hydrogen, and calculating the fuel cell efficiency when it is used as electrical energy generator. This project is of great importance insofar as students will need to acquire several skills to be able to realize it such as continuous DC DC conversion and the scientific concept behind the converter, the regulation of systems with integral proportional controllers, the installation of photovoltaic cells, the use of high-tech sensors, microcontroller programming, object-oriented programming, mastery of the fuel cell syste

  10. High frequency three-phase PWM grid connected drive using silicon-carbide switches

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Pedersen, Jacob Lykke; Nymand, Morten

    2016-01-01

    This paper presents controller design procedure for a fully silicon-carbide (SiC) based three-phase grid-connected PWM drive. The influence of the feedforward compensation for the presented setup is studied and the transfer function of the system with feedforward is derived and compared with the ......This paper presents controller design procedure for a fully silicon-carbide (SiC) based three-phase grid-connected PWM drive. The influence of the feedforward compensation for the presented setup is studied and the transfer function of the system with feedforward is derived and compared...

  11. Effects of Enrofloxacin Administration on Semen Quality of Barbari bucks

    Directory of Open Access Journals (Sweden)

    Chandrima Sinha

    2012-07-01

    Full Text Available The present study was undertaken to study the effect of enrofloxacin administration on semen quality of Barbari buck. Six normal, healthy adult Barbari bucks (25-30 Kg aged between 2 to 2.5 years were used as semen donors. The bucks were administered enrofloxacin at the dose of 5mg/kg body weight intra-muscularly daily for 7 days. From each buck biweekly eighteen semen ejaculates (1st to 18th were collected and one sample (0th from each buck was collected before administration of enrofloxacin, using a non-oestrous doe as dummy and investigated for semen quality parameters. There was no significant difference (P≥0.05 in seminal volume between different ejaculates. Mass motility decreased significantly (P≤0.01 and was lowest in 4th ejaculate as compared to mass motility prior to drug administration. Highest significant (P≤0.01 decrease in progressive motility was seen in 9th ejaculate as compared to progressive motility before drug administration. Sperm concentration decreased significantly (P≤0.01 and was found to be lowest in 4th ejaculate as compared to sperm concentration before enrofloxacin administration. Percent live spermatozoa decreased significantly (P≤0.01 and was found to be minmum in 12th ejaculate as compared to sperm concentration prior to drug administration. Highest significant increase (P≤ 0.01 in per cent head, mid-piece and tail abnormalities of spermatozoa was observed in 4th, 3rd and 6th ejaculate respectively following parentral administration of enrofloxacion as compared to ejaculate before drug administration. Following drug administration, the semen quality decreased progressively and then became slowly normal after 14th ejaculate.

  12. Buck Creek River Flow Analysis

    Science.gov (United States)

    Dhanapala, Yasas; George, Elizabeth; Ritter, John

    2009-04-01

    Buck Creek flowing through Springfield Ohio has a number of low-head dams currently in place that cause safety issues and sometimes make it impossible for recreational boaters to pass through. The safety issues include the back eddies created by the dams that are known as drowning machines and the hydraulic jumps. In this study we are modeling the flow of Buck Creek using topographical and flow data provided by the Geology Department of Wittenberg University. The flow is analyzed using Hydraulic Engineering Center - River Analysis System software (HEC-RAS). As the first step a model of the river near Snyder Park has been created with the current structure in place for validation purposes. Afterwards the low-head dam is replaced with four drop structures with V-notch overflow gates. The river bed is altered to reflect plunge pools after each drop structure. This analysis will provide insight to how the flow is going to behave after the changes are made. In addition a sediment transport analysis is also being conducted to provide information about the stability of these structures.

  13. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-11-09

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  14. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    Science.gov (United States)

    Khan, Md. Rajibur Rahaman; Kang, Shin-Won

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal’s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R2 is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry–Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors. PMID:27834865

  15. Transistor Clamped Five-Level Inverter using Non-Inverting Double Reference Single Carrier PWM Technique for photovoltaic applications

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar; Fedák, Viliam

    2017-01-01

    in output waveform. Under-modulation (modulation Index = 0.85), unity (modulation Index =1) and over-modulation (modulation Index = 1.25) PWM signal is obtained to drive control switches. Simulation results will confirm the functionality, design and operation of the proposed MLI and NIDRSC PWM Technique....

  16. Digital simulation of FM-ZCS-quasi resonant converter fed DD servo drive using Matlab Simulink

    Directory of Open Access Journals (Sweden)

    Kattamuri Narasimha Rao

    2009-01-01

    Full Text Available This paper deals with digital simulation of FM-ZCS-quasi resonant converter fed DC servo drive using Matlab Simulink. Quasi Resonant Converter (QRC is fast replacing conventional PWM converters in high frequency operation. The salient feature of QRC is that the switching devices can be either switched on at zero voltage or switched off at zero current, so that switching losses are zero ideally. Switching stresses are low, volumes are low and power density is high. This property imparts high efficiency and high power density to the converters. The output of QRC is regulated by varying the switching frequency of the converter. Hence it is called Frequency modulated Zero current/zero voltage switching quasi resonant converter. The present work deals with simulation of DC Servo motor fed from ZCS-QRC using Matlab. Simulation results show that the ZCS-QRC's have low total harmonic distortion. The ZCS-QRC operating in half wave and full wave modes are simulated successfully. .

  17. Diode-Assisted Buck-Boost Voltage-Source Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus

    2009-01-01

    , a number of diode-assisted inverter variants can be designed with each having its own operational principle and voltage gain expression. For controlling them, a generic modulation scheme that can be used for controlling all diode-assisted variants with minimized harmonic distortion and component stress......This paper proposes a number of diode-assisted buck-boost voltage-source inverters with a unique X-shaped diode-capacitor network inserted between the inverter circuitry and dc source for producing a voltage gain that is comparatively higher than those of other buck-boost conversion techniques....... Using the diode-assisted network, the proposed inverters can naturally configure themselves to perform capacitive charging in parallel and discharging in series to give a higher voltage multiplication factor without compromising waveform quality. In addition, by adopting different front-end circuitries...

  18. Control Strategy of PWM Rectifiers Connected to Unbalanced Grids

    Czech Academy of Sciences Publication Activity Database

    Bejvl, Martin; Švec, J.; Tlustý, J.; Valouch, V.

    -, č. 11 (2013) ISSN 2172-038X. [International Conference on Renewable Energies and Power Quality (ICREPQ´13). Bilbao, 20.03.2013-22.03.2013] Institutional support: RVO:61388998 Keywords : electric power system * PWM rectifier * dc voltage ripple Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  19. Thermal loading and reliability of 10 MW multilevel wind power converter at different wind roughness classes

    DEFF Research Database (Denmark)

    Isidori, Andrea; Rossi, Fabio Mario; Blaabjerg, Frede

    2012-01-01

    This paper focuses on the design, thermal loading and reliability of a three-level Neutral Point Clamped (3-L NPC) back-to-back full scale converter for a 10 MW direct-drive wind turbine equipped with a Permanent Magnet Synchronous Generator (PMSG). The reliability performance of the three......-level converter is strongly influenced by the thermal behaviour of the semiconductor devices and their mission profile which directly affects the lifetime and the cost of the whole converter. Therefore, the simulation platform is developed in Matlab/Simulink and PLECS simulation environment to analyse...... the dynamics of the system using different kinds of modulation strategies and analyzing different wind load conditions dependent on roughness classes. It is concluded that 60° discontinuous PWM modulation strategies show better thermal performance and increase the estimated lifetime of the converter...

  20. Adaptive electrothermal protection of power converters

    Directory of Open Access Journals (Sweden)

    Baraniuk G. A.

    2017-06-01

    Full Text Available Thermal management for power converters during normal operation and transient modes when electrical components are warmed up is an actual problem. This can be particularly important for converters with intermittent duty operation, e.g. power supplies for resistance welding. According to some research, nearly 60% of failures are temperature-induced, and for every 10°C temperature rise in operating environment the failure rate nearly doubles. In this paper, thermal motion of state equations eigenvalue is analysed. It is shown, that in semiconductor converters with an output smoothing filter it is appropriate to use thermal protection devices based on thermal normalisation of the converter filter and, while for cases when short circuits are possible it is appropriate to use a soft start system with thermal adaptation for soft start time factor. Based on these results, two systems of thermal protections operating for semiconductor power converters are introduced. Simulation of combined electromagnetic and thermal processes in buck converter operating with both thermal management systems in overlapping environments MATLAB/Simulink and PLECS showed the possibility to significantly reduce thermal shock on semiconductor components. Using the system of filter parameters normalisation decreases the temperature of the crystal from 210°C to 85°C, using the adaptive soft start system decreases the temperature from 180°C to 80°C. The simulation results are confirmed by tests on real devices.

  1. Parallel implementation of DNA sequences matching algorithms using PWM on GPU architecture.

    Science.gov (United States)

    Sharma, Rahul; Gupta, Nitin; Narang, Vipin; Mittal, Ankush

    2011-01-01

    Positional Weight Matrices (PWMs) are widely used in representation and detection of Transcription Factor Of Binding Sites (TFBSs) on DNA. We implement online PWM search algorithm over parallel architecture. A large PWM data can be processed on Graphic Processing Unit (GPU) systems in parallel which can help in matching sequences at a faster rate. Our method employs extensive usage of highly multithreaded architecture and shared memory of multi-cored GPU. An efficient use of shared memory is required to optimise parallel reduction in CUDA. Our optimised method has a speedup of 230-280x over linear implementation on GPU named GeForce GTX 280.

  2. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  3. Connection coefficients between Boas-Buck polynomial sets

    Science.gov (United States)

    Cheikh, Y. Ben; Chaggara, H.

    2006-07-01

    In this paper, a general method to express explicitly connection coefficients between two Boas-Buck polynomial sets is presented. As application, we consider some generalized hypergeometric polynomials, from which we derive some well-known results including duplication and inversion formulas.

  4. Grid-connected Photovoltaic Micro-inverter with New Hybrid Control LLC Resonant Converter

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Qingbo, Ke

    2016-01-01

    A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse-frequency modulat......A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse......-frequency modulation (PFM) and phase-shift pulse-width modulation (PS-PWM) is employed on a full-bridge LLC dc-dc converter, in order to achieve high efficiency when PV output voltage varies in a wide range. Moreover, a maximum power point tracking (MPPT) method based on power perturbation is implemented in the dc...

  5. A DEMODULATOR OF PWM SIGNALS GENERATED FOR A DIGITAL ACCELEROMETER IS DEVELOPED USING A MICROCONTROLLER UN DEMODULADOR DE SEÑALES PWM GENERADAS POR UN ACELERÓMETRO DIGITAL ES DESARROLLADO USANDO UN MICROCONTROLADOR

    Directory of Open Access Journals (Sweden)

    Eduardo Pérez Lobato

    2006-08-01

    Full Text Available This paper presents the use of a microcontroller to demodulate two Pulse Width Modulated (PWM signals which are being generated by a digital accelerometer, to obtain their pulse widths and transmit them serially to a parallel port of a general purpose computer.Esta publicación presenta el uso de un microcontrolador para demodular dos señales PWM que están siendo generadas por un acelerómetro digital, obtener sus anchos y enviarlas en forma serial al puerto paralelo de un computador de propósitos generales.

  6. New three-phase ac-ac converter incorporating three-phase boost integrated ZVT bridge and single-phase HF link

    International Nuclear Information System (INIS)

    Abdelhamid, Tamer H.; Sabzali, Ahmad J.

    2008-01-01

    This paper presents a new zero voltage transition (ZVT), power factor corrected three phase ac-ac converter with single phase high frequency (HF) link. It is a two stage converter; the first stage is a boost integrated bridge converter (combination of a 3 ph boost converter and a bridge converter) operated at fixed frequency and that operates in two modes at ZVT for all switches and establishes a 1 ph square wave HF link. The second stage is a bi-directional pulse width modulation (PWM) 3 ph bridge that converts the 1 ph HF link to a 3 ph voltage using a novel switching strategy. The converter modes of operation and key equations are outlined. Simulation of the overall system is conducted using Simulink. The switching strategy and its corresponding control circuit are clearly described. Experimental verification of the simulation is conducted for a prototype of 100 V, 500 W at 10 kHz link frequency

  7. A high efficiency PWM CMOS class-D audio power amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Zhangming; Liu Lianxi; Yang Yintang [Institute of Microelectronics, Xidian University, Xi' an 710071 (China); Lei Han, E-mail: zmyh@263.ne [Xi' an Power-Rail Micro Co., Ltd, Xi' an 710075 (China)

    2009-02-15

    Based on the difference close-loop feedback technique and the difference pre-amp, a high efficiency PWM CMOS class-D audio power amplifier is proposed. A rail-to-rail PWM comparator with window function has been embedded in the class-D audio power amplifier. Design results based on the CSMC 0.5 mum CMOS process show that the max efficiency is 90%, the PSRR is -75 dB, the power supply voltage range is 2.5-5.5 V, the THD+N in 1 kHz input frequency is less than 0.20%, the quiescent current in no load is 2.8 mA, and the shutdown current is 0.5 muA. The active area of the class-D audio power amplifier is about 1.47 x 1.52 mm{sup 2}. With the good performance, the class-D audio power amplifier can be applied to several audio power systems.

  8. A high efficiency PWM CMOS class-D audio power amplifier

    International Nuclear Information System (INIS)

    Zhu Zhangming; Liu Lianxi; Yang Yintang; Lei Han

    2009-01-01

    Based on the difference close-loop feedback technique and the difference pre-amp, a high efficiency PWM CMOS class-D audio power amplifier is proposed. A rail-to-rail PWM comparator with window function has been embedded in the class-D audio power amplifier. Design results based on the CSMC 0.5 μm CMOS process show that the max efficiency is 90%, the PSRR is -75 dB, the power supply voltage range is 2.5-5.5 V, the THD+N in 1 kHz input frequency is less than 0.20%, the quiescent current in no load is 2.8 mA, and the shutdown current is 0.5 μA. The active area of the class-D audio power amplifier is about 1.47 x 1.52 mm 2 . With the good performance, the class-D audio power amplifier can be applied to several audio power systems.

  9. A high efficiency PWM CMOS class-D audio power amplifier

    Science.gov (United States)

    Zhangming, Zhu; Lianxi, Liu; Yintang, Yang; Han, Lei

    2009-02-01

    Based on the difference close-loop feedback technique and the difference pre-amp, a high efficiency PWM CMOS class-D audio power amplifier is proposed. A rail-to-rail PWM comparator with window function has been embedded in the class-D audio power amplifier. Design results based on the CSMC 0.5 μm CMOS process show that the max efficiency is 90%, the PSRR is -75 dB, the power supply voltage range is 2.5-5.5 V, the THD+N in 1 kHz input frequency is less than 0.20%, the quiescent current in no load is 2.8 mA, and the shutdown current is 0.5 μA. The active area of the class-D audio power amplifier is about 1.47 × 1.52 mm2. With the good performance, the class-D audio power amplifier can be applied to several audio power systems.

  10. Electrothermal model of choking-coils for the analysis of dc-dc converters

    Energy Technology Data Exchange (ETDEWEB)

    Gorecki, Krzysztof, E-mail: gorecki@am.gdynia.pl [Gdynia Maritime University, Department of Marine Electronics, Morska 83, Gdynia (Poland); Detka, Kalina [Pomeranian Higher School in Gdynia, Opata Hackiego 8-10, Gdynia (Poland)

    2012-09-01

    The paper concerns modelling the choking-coil for the needs of the electrothermal analysis of dc-dc converters. A new electrothermal model of the choking-coil is proposed. This model is dedicated for SPICE software and it takes into account nonlinearity of the dependences of the inductance on the current, selfheating and mutual thermal interactions between the core and the winding. The structure of this model is described in detail and its correctness is experimentally verified for the choking-coils with the ferrite and powder cores. Both the characteristics of the choking-coils and the buck converter with these choking-coils were considered. The satisfying agreement between the results of calculations and measurements is obtained.

  11. Electrothermal model of choking-coils for the analysis of dc–dc converters

    International Nuclear Information System (INIS)

    Górecki, Krzysztof; Detka, Kalina

    2012-01-01

    The paper concerns modelling the choking-coil for the needs of the electrothermal analysis of dc–dc converters. A new electrothermal model of the choking-coil is proposed. This model is dedicated for SPICE software and it takes into account nonlinearity of the dependences of the inductance on the current, selfheating and mutual thermal interactions between the core and the winding. The structure of this model is described in detail and its correctness is experimentally verified for the choking-coils with the ferrite and powder cores. Both the characteristics of the choking-coils and the buck converter with these choking-coils were considered. The satisfying agreement between the results of calculations and measurements is obtained.

  12. A Reconfigurable Series Resonant DC-DC Converter for Wide-Input and Wide-Output Voltages

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Qin, Zian

    2017-01-01

    This paper proposes a dual-bridge based LC series resonant dc-dc converter. The input inverter unit incorporates two bridge structures, i.e., a full-bridge inverter and a half-bridge inverter. For the output rectifier, it can be a full-bridge rectifier or an asymmetric half-bridge rectifier....... Different from the conventional resonant converter, a fixed-frequency PWM control is employed which makes the optimization of magnetic components easier. The primary-side switches can achieve ZVS and the secondary-side diodes turn off with ZCS. In addition, the root-mean-square (RMS) values...... of the transformer currents do not significantly vary with respect to the voltage variation. Therefore, this converter can maintain high efficiency over a wide voltage range. The topology and operating principle are firstly described. Then the dc voltage gain and the RMS current characteristics are detailed. Finally...

  13. Direct switching control of DC-DC power electronic converters using hybrid system theory

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, J.; Lin, F. [Wayne State Univ., Detroit, MI (United States). Dept. of Electrical and Computer Engineering; Wang, C. [Wayne State Univ., Detroit, MI (United States). Dept. of Electrical and Computer Engineering; Wayne State Univ., Detroit, MI (United States). Div. of Engineering Technology

    2010-07-01

    A direct switching control (DSC) scheme for power electronics converters was described. The system was designed for use in both traditional and renewable energy applications as well as in electric drive vehicles. The proposed control scheme was based on a detailed hybrid system converter model that used model predictive control (MPC), piecewise affine (PWA) approximations and constrained optimal control methods. A DC-DC converter was modelled as a hybrid machine. Switching among different modes of the DC-DC converter were modelled as discrete events controlled by the hybrid controller. The modelling scheme was applied to a Buck converter. The DSC was used to control the switch of the power converter based on a hybrid machine model. Results of the study showed that the method can be used to regulate output voltage and inductor currents. The method also provides fast transient responses and effectively regulates both currents and voltage. The controller can be used to provide immediate responses to dynamic disturbances and output voltage fluctuations. 23 refs., 7 figs.

  14. Bifurcation-free design method of pulse energy converter controllers

    International Nuclear Information System (INIS)

    Kolokolov, Yury; Ustinov, Pavel; Essounbouli, Najib; Hamzaoui, Abdelaziz

    2009-01-01

    In this paper, a design method of pulse energy converter (PEC) controllers is proposed. This method develops a classical frequency domain design, based on the small signal modeling, by means of an addition of a nonlinear dynamics analysis stage. The main idea of the proposed method consists in fact that the PEC controller, designed with an application of the small signal modeling, is tuned after with taking into the consideration an essentially nonlinear nature of the PEC that makes it possible to avoid bifurcation phenomena in the PEC dynamics at the design stage (bifurcation-free design). Also application of the proposed method allows an improvement of the designed controller performance. The application of this bifurcation-free design method is demonstrated on an example of the controller design of direct current-direct current (DC-DC) buck converter with an input electromagnetic interference filter.

  15. Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Krim, Fateh; Gaubert, Jean-Paul

    2009-01-01

    This paper proposes direct power control (DPC) for three-phase PWM rectifiers using a new switching table, without line voltage sensors. The instantaneous active and reactive powers, directly controlled by selecting the optimum state of the converter, are used as the PWM control variables instead of the phase line currents being used. The main goal of the control system is to maintain the dc-bus voltage at the required level, while input currents drawn from the power supply should be sinusoidal and in phase with respective phase voltages to satisfy the unity power factor (UPF) operation. Conventional PI and a designed fuzzy logic-based controller, in the dc-bus voltage control loop, have been used to provide active power command. A dSPACE based experimental system was developed to verify the validity of the proposed DPC. The steady-state, and dynamic results illustrating the operation and performance of the proposed control scheme are presented. As a result, it was confirmed that the novel DPC is much better than the classical one. Line currents very close to sinusoidal waveforms (THD < 2%) and good regulation of dc-bus voltage are achieved using PI or fuzzy controller. Moreover, fuzzy logic controller gives excellent performance in transient state, a good rejection of impact load disturbance, and a good robustness

  16. The PWM strategies of grid-connected distributed generation active NPC inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Xinmin, Jin; Kerekes, Tamas

    2009-01-01

    The Neutral Point Clamped topology due to high efficiency, low leakage current and EMI, its integration is widely used in the distributed generation (DG) systems. However the main disadvantage of the NPC inverter is given by an unequal distribution of the losses in the semiconductor devices, which...... leads to an unequal distribution of temperature. By using the Active NPC topology, the power losses distribution problem is alleviated. The modulation strategy is a key issue for losses distribution in this topology. In this paper two known strategies are discussed and a new proposed PWM strategy......, namely the Adjustable Losses Distribution (ALD) PWM strategy is proposed for better losses distribution in the Active NPC (ANPC) topology. Simulations using Simulink and the PLECS toolbox have been done for evaluating efficiency of different NPC topologies and some experimental results are presented...

  17. CCLIBS: The CERN Power Converter Control Libraries

    CERN Document Server

    AUTHOR|(SzGeCERN)404953; Lebioda, Krzysztof Tomasz; Magrans De Abril, Marc; Martino, Michele; Murillo Garcia, Raul; Nicoletti, Achille

    2015-01-01

    Accurate control of power converters is a vital activity in large physics projects. Several different control scenarios may coexist, including regulation of a circuit’s voltage, current, or field strength within a magnet. Depending on the type of facility, a circuit’s reference value may be changed asynchronously or synchronously with other circuits. Synchronous changes may be on demand or under the control of a cyclic timing system. In other cases, the reference may be calculated in real-time by an outer regulation loop of some other quantity, such as the tune of the beam in a synchrotron. The power stage may be unipolar or bipolar in voltage and current. If it is unipolar in current, it may be used with a polarity switch. Depending on the design, the power stage may be controlled by a firing angle or PWM duty-cycle reference, or a voltage or current reference. All these cases are supported by the CERN Converter Control Libraries (CCLIBS). These open-source C libraries include advanced reference generati...

  18. Design of DC-DC Converter and its Control for a Wind Generation System Connected to an Isolated Load

    Directory of Open Access Journals (Sweden)

    Carlos A. Ramírez Gómez

    2013-11-01

    Full Text Available A method to design a Buck converter and its control, which are associated to a wind generation system that is feeding an isolated load, is presented in this paper. To design the converter a Thevenin equivalent is deduced, which represents the behavior of the wind turbine, the permanent magnet synchronous generator, and the rectifier. The design of the converter elements guarantees input/output voltages and inductor current ripples of 5 % or less. The output voltage control is developed with a proportional-integral-derivative controller and as design criteria a damping of 0,707 and cutoff frequency of 1/5 converter commutation frequency are selected. The designed controller regulates the output voltage faced load perturbations and wind speed variations. 

  19. A Review of Passive Filters for Grid-Connected Voltage Source Converters

    DEFF Research Database (Denmark)

    Beres, Remus Narcis; Wang, Xiongfei; Blaabjerg, Frede

    2014-01-01

    LCL filter is the common interface between the Pulse Width Modulated Voltage Source Converter (PWM VSC) and the utility grid due to high harmonic attenuation capability and reduced size of the passive elements. The present paper investigates the most promising passive damping methods for the LCL...... topology but also propose an overview of high order filters capable to offer even more attenuation than the LCL filter at a reduced size. This is the case of more recently introduced LCL topology with tuned traps. However, it is shown that by decreasing the size of the passive elements the robustness...

  20. Modeling, Analysis and Control of Different DC-DC Converter Topologies for Photo Voltaic Emulator

    Directory of Open Access Journals (Sweden)

    Mohammad Tauquir Iqbal

    2016-05-01

    Full Text Available This paper presents the modeling, analysis and control of different DC-DC converter topologies to emulate the photovoltaic (PV system. A PV emulator is basically a DC-DC converter having same electrical characteristics that of solar PV panel.  The emulator helps to achieve real characteristics of PV system in a better way in an environment where using actual PV systems can produce inconsistent results due to variation in weather conditions. The paper describes different types of DC-DC converters like buck, Resonant and Quasi Resonant Converter. The complete system is modelled in MATLAB® Simulink SimPowerSystem software package. The Simulation results obtained from the MATLAB® Simulink SimPowerSystem software package for different topologies under steady and dynamic conditions are analyzed and presented. An evaluation table is also presented at the end of the paper, presenting the effectiveness of each topology.

  1. A New Sliding Mode Controller for DC/DC Converters in Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    M. Sarvi

    2013-01-01

    Full Text Available DC/DC converters are widely used in many industrial and electrical systems. As DC/DC converters are nonlinear and time-variant systems, the application of linear control techniques for the control of these converters is not suitable. In this paper, a new sliding mode controller is proposed as the indirect control method and compared to a simple direct control method in order to control a buck converter in photovoltaic applications. The solar arrays are dependent power sources with nonlinear voltage-current characteristics under different environmental conditions (insolation and temperature. From this point of view, the DC/DC converter is particularly suitable for the application of the sliding mode control in photovoltaic application, because of its controllable states. Simulations are performed in Matlab/Simulink software. The simulation results are presented for a step change in reference voltage and input voltage as well as step load variations. The simulations results of proposed method are compared with the conventional PID controller. The results show the good performance of the proposed sliding mode controller. The proposed method can be used for the other DC/DC converter.

  2. High-Speed Universal Frequency-to-Digital Converter for Quasi-Digital Sensors and Transducers

    Directory of Open Access Journals (Sweden)

    Sergey Y. Yurish

    2007-06-01

    Full Text Available New fast, accurate universal integrated frequency-to-digital converter (UFDC-1M-16 is described in the article. It is based on the novel patented modified method of the dependent count and has non-redundant conversion time from 6.25 ms to 6.25 ms for 1 to 0.001 % relative errors respectively, comparable with conversion time for successive-approximation and S-D ADC. The IC can work with different sensors, transducers and encoders, which have frequency, period, duty-cycle, PWM, phase shift, pulse number, etc. output.

  3. Shunt PWM advanced var compensators based on voltage source inverters for Facts applications

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Pedro G; Misaka, Isamu; Watanabe, Edson H [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1994-12-31

    Increased attention has been given to improving power system operation. This paper presents modeling, analysis and design of reactive shunt power compensators based on PWM-Voltage Source Inverters (Pulse Width Modulation -Voltage Source Inverters). (Pulse Width Modulation - Voltage Source Inverters). The control algorithm is based on new concepts of instantaneous active and reactive power theory. The objective is to show that with a small capacitor in the side of a 3-phase PWM-VSI it is possible to synthesize a variable reactive (capacitive or inductive) device. Design procedures and experimental results are presented. The feasibility of this method was verified by digital simulations and measurements on a small scale model. (author) 9 refs., 12 figs.

  4. Spectral shaping of a randomized PWM DC-DC converter using maximum entropy probability distributions

    CSIR Research Space (South Africa)

    Dove, Albert

    2017-01-01

    Full Text Available maintaining constraints in a DC-DC converter is investigated. A probability distribution whose aim is to ensure maximal harmonic spreading and yet mainaint constraints is presented. The PDFs are determined from a direct application of the method of Maximum...

  5. Diode-Assisted Buck-Boost Current Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Cai, Liang; Loh, P.C.

    2007-01-01

    This paper presents a couple of novel current source inverters (CSIs) with the enhanced current buckboost capability. With the unique diode-inductor network added between current source inverter circuitry and current boost elements, the proposed buck-boost current source inverters demonstrate...... uninfluenced. Lastly, all theoretical findings were verified experimentally using constructed laboratory prototypes....

  6. Reduction in electromagnetic interference of switching converters using self-excitation-chaos

    DEFF Research Database (Denmark)

    Li, Qingnan; Xiong, Rui; He, Ou

    2008-01-01

    operating in chaos, the simulation results demonstrate that a reduction of spectral peak and consequent spreading of the spectrum can be shown, any desirable amount of reduction and consequent spreading of the spectrum can be obtained simply by varying the control parameter of the circuit and a optimization......We derived a second-order S-switching iterative map describing the dynamics of simple feedback Buck switching regulator operating in continuous mode. Analysis of this map shows that chaos and bifurcations may occur along with the changing of values of some system parameters. By making the converter...

  7. The Chaotic-Based Control of Three-Port Isolated Bidirectional DC/DC Converters for Electric and Hybrid Vehicles

    Directory of Open Access Journals (Sweden)

    Zheng Wang

    2016-01-01

    Full Text Available Three-port isolated (TPI bidirectional DC/DC converters have three energy ports and offer advantages of large voltage gain, galvanic isolation ability and high power density. For this reason this kind of converters are suitable to connect different energy sources and loads in electric and hybrid vehicles. The purpose of this paper is to propose chaotic modulation and the related control scheme for TPI bidirectional DC/DC converters, in such a way that the switching harmonic peaks can be suppressed in spectrum and the conducted electromagnetic interference (EMI is reduced. Two chaotic modulation strategies, namely the continuously chaotic modulation and the discretely chaotic modulation are presented. These two chaotic modulation strategies are applied for TPI bidirectional DC/DC converters with shifted-phase angle based control and phase-shifted PWM control. Both simulation and experiments are given to verify the validity of the proposed chaotic modulation-based control schemes.

  8. Analysis of transistor and snubber turn-off dynamics in high-frequency high-voltage high-power converters

    Science.gov (United States)

    Wilson, P. M.; Wilson, T. G.; Owen, H. A., Jr.

    Dc to dc converters which operate reliably and efficiently at switching frequencies high enough to effect substantial reductions in the size and weight of converter energy storage elements are studied. A two winding current or voltage stepup (buck boost) dc-to-dc converter power stage submodule designed to operate in the 2.5-kW range, with an input voltage range of 110 to 180 V dc, and an output voltage of 250 V dc is emphasized. In order to assess the limitations of present day component and circuit technologies, a design goal switching frequency of 10 kHz was maintained. The converter design requirements represent a unique combination of high frequency, high voltage, and high power operation. The turn off dynamics of the primary circuit power switching transistor and its associated turn off snubber circuitry are investigated.

  9. Impact of frequency modulation ratio on capacitor cells balancing in phase-shifted PWM based chain-link STATCOM

    DEFF Research Database (Denmark)

    Behrouzian, Ehsan; Bongiorno, Massimo; Teodorescu, Remus

    2014-01-01

    to provide more uniform power distribution among the cells, two different methods called, a) carrier swapping and b) non-integer frequency modulation ratio are studied. In particular, it is shown that the selection of a non-integer frequency modulation ratio helps in providing a more uniform power......The purpose of this paper is to investigate the impact of switching harmonics on the instantaneous power that flows in the cells of a chain-link based STATCOM when using Phase-Shifted PWM. Two different cases are investigated for the converter cells: low, and high switching frequency. It is shown...... that any deviation from the ideal conditions lead to undesired harmonics, which will impact the charge of the dc capacitors. It is also shown that for low switching frequencies, cells voltage sideband harmonics interact with baseband harmonics of the current and causes extra source of unbalance. In order...

  10. Design and Implementation of High Frequency Buck Converter Using Multi-Layer PCB Inductor

    DEFF Research Database (Denmark)

    Nour, Yasser; Ouyang, Ziwei; Knott, Arnold

    2016-01-01

    Increasing the switching frequency for switch mode power supplies is one of methods to achieve smaller, lighter weight and cheaper power converters. This work investigates the opportunity of using two layer circular spiral inductors implemented in a 150 μm finished thickness printed circuit board...

  11. Color deviations in phosphor converted high power light emitting diodes under different dimming schemes

    International Nuclear Information System (INIS)

    Ludwiczak, Bogna; Jantsch, Wolfgang

    2015-01-01

    We investigate experimentally the color stability of high power phosphor converted InGaN LEDs under pulse width modulation (PWM) and continuous current reduction (CCR) dimming modes and for varied operation temperatures. Our measurements reveal that the chromaticity coordinate pathways of the warm white and the cold white LED's differ for the same operation conditions. The color deviation- minimizing phenomenon of opposite peak wavelength shifts appears only for a cold white LED under CCR driving mode. This favorable effect does not occur for warm white LEDs. This type of LED exhibits the best color stability under PWM driving mode. The experimental results are consistently explained in terms of the quantum confined Stark effect and temperature induced changes of the LED emission. - Highlights: • Cold and warm white LEDs reacts colorimetrically unlike in different driving modes. • For cold white emission driving conditions are crucial. • Opposite peak wavelength shifts reduces color deviations for cold white emission. • For warm white emission rather phosphor properties determines color deviations

  12. Evaluation and optimization of the bandwidth of static converters: application to multi-cell converters; Evaluation et optimisation de la bande passante des convertisseurs statiques

    Energy Technology Data Exchange (ETDEWEB)

    Aime, M.

    2003-11-15

    Thanks to the technological progress achieved in the field of power electronics, the use of static converters has spread to new applications. In particular, some applications such as active filtering or the supply of special AC machines require power converters having good dynamic performances. The subject of this thesis is to evaluate systematically the dynamic performances of multi-cell converters, and then to optimize these performances. This document is organized in four chapters. The first one summarizes the main multilevel converter structures, and some control strategies dedicated to these structures. The second chapter presents the evaluation criteria chosen to quantify the dynamic performances of static converters. These criteria are then used to compare the performances obtained with two different PWM strategies. An optimized strategy which results from a trade-off between the two former strategies is then introduced. The third chapter shows a new control strategy of multi-cell voltage source converters. This new strategy enables to control the peak current at a fixed switching frequency. The operation of this controller is explained, and the results obtained by digital simulations are presented and discussed. The fourth chapter deals with the experimental achievement of the peak current control. In particular, the implementation of the control algorithm within a FPGA is demonstrated. Finally, the conclusion of this thesis presents some orientations for further developments, in order to improve the current control strategy and to widen its field of applications. (author)

  13. Application of digital PWM technology in current transducers

    International Nuclear Information System (INIS)

    Liu Huifang; Hu Zhimin; Li Rui

    2012-01-01

    With the development of DSP technology and mature use of PID technology,, a new program for DC or AC signal measurement is proposed. Combined with the DSP chip timer module and PID algorithm, PWM signals are generated to control the feedback circuit for the compensation current. Finally the measured current value can be obtained according to the ampere-turns compensation current and the measured current. Studies have shown that this technology enables new current transducers have high stability. (authors)

  14. Floating high step-down stacked dc-dc converter based on buck-boost cells

    NARCIS (Netherlands)

    Tibola, G.; Duarte, J.L.; Blinov, A.

    2015-01-01

    In some high power dc-dc applications, where high voltage is present, a converter with high step-down ratio is required in order to provide an isolated low power auxiliary supply. This requirement represents a challenge and many topologies are currently being researched. The analysis of a

  15. Stator insulation systems for medium voltage PWM drives fed motors

    International Nuclear Information System (INIS)

    Gao, G.; Chen, W.

    2005-01-01

    This paper presents the partial results of a research project that studied the impact of medium voltage PWM ASD (adjustable speed drives) on motor stator insulation system. The findings from this study/ investigation have aided designers to improve the robustness of the insulation system used for ASD-fed motors, based on accelerated laboratory tests. (author)

  16. A High-Frequency Isolation (HFI Charging DC Port Combining a Front-End Three-Level Converter with a Back-End LLC Resonant Converter

    Directory of Open Access Journals (Sweden)

    Guowei Cai

    2017-09-01

    Full Text Available The high-frequency isolation (HFI charging DC port can serve as the interface between unipolar/bipolar DC buses and electric vehicles (EVs through the two-power-stage system structure that combines the front-end three-level converter with the back-end logical link control (LLC resonant converter. The DC output voltage can be maintained within the desired voltage range by the front-end converter. The electrical isolation can be realized by the back-end LLC converter, which has the bus converter function. According to the three-level topology, the low-voltage rating power devices can be adapted for half-voltage stress of the total DC grid, and the PWM phase-shift control can double the equivalent switching frequency to greatly reduce the filter volume. LLC resonant converters have advance characteristics of inverter-side zero-voltage-switching (ZVS and rectifier-side zero-current switching (ZCS. In particular, it can achieve better performance under quasi-resonant frequency mode. Additionally, the magnetizing current can be modified following different DC output voltages, which have the self-adaptation ZVS condition for decreasing the circulating current. Here, the principles of the proposed topology are analyzed in detail, and the design conditions of the three-level output filter and high-frequency isolation transformer are explored. Finally, a 20 kW prototype with the 760 V input and 200–500 V output are designed and tested. The experimental results are demonstrated to verify the validity and performance of this charging DC port system structure.

  17. A Dual-Buck–Boost AC/DC Converter for DC Nanogrid With Three Terminal Outputs

    DEFF Research Database (Denmark)

    Wu, Weimin; Wang, Houqing; Liu, Yuan

    2017-01-01

    Due to the widely used dc characterized loads and more distributed power generation sources, the dc nanogrid becomes more and more popular, and it is seen as an alternative to the ac grid. For safety considerations, the dc nanogrid should provide reliable grounding for the residential loads...... such as the low-voltage ac power system. There are three typical grounding configurations for a dc nanogrid: the united grounding, the unidirectional grounding, and the virtual isolated grounding. Each grounding configuration has its own specifications to ac/dc converters. In this paper, a dual-buck-boost ac/dc...... converter for use in the united-grounding-configuration-based dc nanogrid with three terminal outputs is proposed. The working principle of this converter is presented in detail through analyzing the equivalent circuits. Experiments are carried out to verify the theoretical analysis....

  18. Microcontroller based PWM controlled four switch three phase inverter fed induction motor drive

    Directory of Open Access Journals (Sweden)

    Mohanty Kant Nalin

    2010-01-01

    Full Text Available This paper presents PIC microcontroller based PWM inverter controlled four switch three phase inverter (FSTPI fed Induction Motor drive. The advantage of this inverter that uses of 4 switches instead of conventional 6 switches is lesser switching losses, lower electromagnetic interference (EMI, less complexity of control algorithms and reduced interface circuits. Simulation and experimental work are carried out and results presented to demonstrate the feasibility of the proposed approach. Simulation is carried out using MATLAB SIMULINK and in the experimental work a prototype model is built to verify the simulation results. PIC microcontroller (PIC 16F877A is used to generate the PWM pulses for FSTPI to drive the 0.5 hp 3-phase Induction Motor.

  19. Asymmetrical Interleaved DC/DC Switching Converters for Photovoltaic and Fuel Cell Applications—Part 1: Circuit Generation, Analysis and Design 

    Directory of Open Access Journals (Sweden)

    Sergio Serna

    2012-11-01

    Full Text Available A novel asymmetrical interleaved dc/dc switching converters family intended for photovoltaic and fuel cell applications is presented in this paper. The main requirements on such applications are small ripples in the generator and load, as well as high voltage conversion ratio. Therefore, interleaved structures and voltage multiplier cells have been asymmetrically combined to generate new converters, which inherently operate indiscontinuous conduction mode. The novel family is derived from boost, buck-boost and flyback-based structures. This converter family is analyzed to obtain the design equations and synthesize a design process based on the typical requirements of photovoltaic and fuel cell applications. Finally, the experimental results validate the characteristics and usefulness of the asymmetrical interleaved converter family. 

  20. A Feedback Passivation Design for DC Microgrid and Its DC/DC Converters

    Directory of Open Access Journals (Sweden)

    Feifan Ji

    2016-12-01

    Full Text Available There are difficulties in analyzing the stability of microgrids since they are located on various network structures. However, considering that the network often consists of passive elements, the passivity theory is applied in this paper to solve the above-mentioned problem. It has been formerly shown that when the network is weakly strictly positive real (WSPR, the DC microgrid is stable if all interfaces between the microgrid and converters are made to be passive, which is called interface passivity. Then, the feedback passivation method is proposed for the controller design of various DC–DC converters to achieve the interface passivity. The interface passivity is different from the passivity of closed-loop systems on which the passivity based control (PBC concentrates. The feedback passivation design is detailed for typical buck converters and boost converters in terms of conditions that the controller parameters should satisfy. The theoretical results are verified by a hardware-in-loop real-time labotray (RTLab simulation of a DC microgrid with four generators.

  1. Performance analysis of pulse analog control schemes for LLC resonant DC/DC converters suitable in portable applications

    Directory of Open Access Journals (Sweden)

    P. Kowstubha

    2016-12-01

    Full Text Available Performance Analysis of Pulse Analog Control Schemes, predominantly Pulse-Width Modulation (PWM and Pulse-Position Modulation (PPM for LLC resonant DC/DC converter suitable in portable applications is addressed in this paper. The analysis is done for closed loop performance, frequency domain performance, primary and secondary side conduction losses and soft commutation using PSIM 6.0 software and observed that PPM scheme provides better performance at high input voltage with a good selectivity of frequency over a wide range of line and load variations. The performance of LLC resonant DC/DC converter is demonstrated using PPM scheme for a design specifications of 12 V, 5 A output.

  2. Male goat vocalizations stimulate the estrous behavior and LH secretion in anestrous goats that have been previously exposed to bucks.

    Science.gov (United States)

    Delgadillo, José Alberto; Vielma, Jesús; Hernandez, Horacio; Flores, José Alfredo; Duarte, Gerardo; Fernández, Ilda Graciela; Keller, Matthieu; Gelez, Hélène

    2012-09-01

    We investigated whether live vocalizations emitted by bucks interacting with anestrous females stimulate secretion of LH, estrous behavior and ovulation in anestrous goats. In experiment 1, bucks rendered sexually active by exposure to long days followed by natural photoperiod were exposed in a light-proof-building to five anestrous females. Buck vocalizations were reproduced through a microphone-amplifier-loudspeaker system to an open pen where one group of goats (n=6) was exposed for 10 days to these live vocalizations. Another group of females (n=6) was isolated from males and vocalizations. The proportion of goats displaying estrous behavior was significantly higher in females exposed to buck vocalizations than in females isolated from males. The proportion of goats that ovulated did not differ between the 2 groups (exposed to males versus isolated). In experiment 2, female goats that either had previous contact with males (n=7), or no previous contact with males (n=7) were exposed to live buck vocalizations, reproduced as described in experiment 1, for 5 days. The number and amplitude of LH pulses did not differ between groups before exposition to buck vocalizations. Five days of exposure to male vocalizations significantly increased LH pulsatility only in females that had previous contact with males, while LH pulse amplitude was not modified. We concluded that live buck vocalizations can stimulate estrous behavior and LH secretion in goats if they have had previous contact with bucks. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Rancang Bangun Maximum Power Point Tracking pada Panel Photovoltaic Berbasis Logika Fuzzy di Buoy Weather Station

    Directory of Open Access Journals (Sweden)

    Bayu Prima Juliansyah Putra

    2013-09-01

    Full Text Available Salah satu aplikasi yang sering digunakan dalam bidang energi terbarukan adalah panel photovoltaic. Panel ini memiliki prinsip kerja berdasarkan efek photovoltaic dimana lempengan logam akan menghasilkan energi listrik apabila diberi intensitas cahaya. Untuk menghasilkan daya keluaran panel yang maksimal, maka diperlukan suatu algoritma yang biasa disebut Maximum Power Point Tracking (MPPT.MPPT yang diterapkan pada sistem photovoltaic berfungsi untuk mengatur nilai tegangan keluaran panel sehingga titik ker-janya beroperasi pada kondisi maksimal. Algoritma MPPT pada panel ini telah dilakukan dengan menggunakan logika fuzzy melalui mikrokontroler Arduino Uno sebagai pem-bangkit sinyal Pulse Width Modulation (PWM yang akan dikirimkan menuju DC-DC Buck Boost Converter. Keluaran dari buck boost converterakan dihubungkan secara langsung dengan buoy weather station untuk menyuplai energi listrik tiap komponen yang berada di dalamnya. Untuk menguji performansi dari algoritma MPPT yang telah dirancang, maka sistem akan diuji menggunakan variasi beban antara metode direct-coupled dengan MPPT menggunakan logika fuzzy. Hasil pengujian menunjukkan bahwa MPPT dengan logika fuzzy dapat menghasilkan daya maksimum daripada direct-coupled. Pada sistem panel photovoltaic ini memiliki range efisiensi 33.07589 % hingga 74.25743 %. Daya mak-simal dapat dicapai oleh sistem untuk tiap variasi beban dan efisiensi maksimal dapat dicapai pada beban 20 Ohm dari hasil pengujian sistem MPPT.

  4. Seasonal changes in reproductive activity, sperm variables and sperm freezability in Blanca Andaluza bucks

    Directory of Open Access Journals (Sweden)

    Lourdes Gallego-Calvo

    2015-12-01

    Full Text Available Interest in the preservation of endangered breeds such as the Blanca Andaluza goat, has increased and some steps should be therefore taken to ensure it. The study was designed to determine the seasonal reproductive pattern of Blanca Andaluza bucks, and whether this affects the quality of their semen and its freezability over the year. Seven bucks were used and their body weight, testicular weight, plasma testosterone concentration and fresh sperm quality determined every week. The collected sperm was cryopreserved and stored; it was then thawed and the same sperm quality variables measured every fortnight. High plasma testosterone concentrations were recorded during the summer and autumn, and low concentrations were recorded during winter and spring (p<0.001. No differences were seen between seasons in terms of the percentage of bucks ejaculating, the percentage of active bucks, or ejaculate volume. However, the sperm concentration, the total number of sperm per ejaculate, and the values for most fresh sperm variables were lower during the winter period (at least p<0.05. After freezing-thawing, the quality of winter-collected sperm was better, in some respects, than that of summer-collected sperm (at least p<0.05. These results reveal that Blanca Andaluza bucks show seasonal reproductive activity in terms of their plasma testosterone concentration, but no clear change in their sexual behaviour between seasons was observed. The values of fresh sperm variables also vary over the year, reaching their lowest during winter. However, after freezing-thawing, winter-collected sperm is of overall better quality than sperm collected during the summer.

  5. Seasonal changes in reproductive activity, sperm variables and sperm freezability in Blanca Andaluza bucks

    Energy Technology Data Exchange (ETDEWEB)

    Gallego-Calvo, L.; Gatica, M.C.; Santiago-Moreno, J.; Guzmán, J.L.; Zarazaga, L.

    2015-07-01

    Interest in the preservation of endangered breeds such as the Blanca Andaluza goat, has increased and some steps should be therefore taken to ensure it. The study was designed to determine the seasonal reproductive pattern of Blanca Andaluza bucks, and whether this affects the quality of their semen and its freezability over the year. Seven bucks were used and their body weight, testicular weight, plasma testosterone concentration and fresh sperm quality determined every week. The collected sperm was cryopreserved and stored; it was then thawed and the same sperm quality variables measured every fortnight. High plasma testosterone concentrations were recorded during the summer and autumn, and low concentrations were recorded during winter and spring (p<0.001). No differences were seen between seasons in terms of the percentage of bucks ejaculating, the percentage of active bucks, or ejaculate volume. However, the sperm concentration, the total number of sperm per ejaculate, and the values for most fresh sperm variables were lower during the winter period (at least p<0.05). After freezing-thawing, the quality of winter-collected sperm was better, in some respects, than that of summer-collected sperm (at least p<0.05). These results reveal that Blanca Andaluza bucks show seasonal reproductive activity in terms of their plasma testosterone concentration, but no clear change in their sexual behaviour between seasons was observed. The values of fresh sperm variables also vary over the year, reaching their lowest during winter. However, after freezing-thawing, winter-collected sperm is of overall better quality than sperm collected during the summer. (Author)

  6. On the Disillusionment of American Dream Through Buck in The Call of the Wild

    Institute of Scientific and Technical Information of China (English)

    吕颖

    2015-01-01

    The Call of the Wild,written by the famous American novelist Jack London,has attracted a large number of both readers and scholars ever since it came out.It provides the public with a fresh perspective through narrating the whole novel from the point of view of the protagonist Buck,a dog.Against the background of countless people flooding into the Alaska to search gold in order to fulfill their dream of becoming rich,which,to some extent,represents the American dream at that time,this novel vividly mirrored the then phenomenon,so illuminating and thought-provoking that it is of great value to analyze the disillusionment of American Dream through Buck.Therefore,this paper aims at exploring the disillusionment of American Dream through analyzing Buck and his rich life experiences.

  7. An improved fault-tolerant control scheme for PWM inverter-fed induction motor-based EVs.

    Science.gov (United States)

    Tabbache, Bekheïra; Benbouzid, Mohamed; Kheloui, Abdelaziz; Bourgeot, Jean-Matthieu; Mamoune, Abdeslam

    2013-11-01

    This paper proposes an improved fault-tolerant control scheme for PWM inverter-fed induction motor-based electric vehicles. The proposed strategy deals with power switch (IGBTs) failures mitigation within a reconfigurable induction motor control. To increase the vehicle powertrain reliability regarding IGBT open-circuit failures, 4-wire and 4-leg PWM inverter topologies are investigated and their performances discussed in a vehicle context. The proposed fault-tolerant topologies require only minimum hardware modifications to the conventional off-the-shelf six-switch three-phase drive, mitigating the IGBTs failures by specific inverter control. Indeed, the two topologies exploit the induction motor neutral accessibility for fault-tolerant purposes. The 4-wire topology uses then classical hysteresis controllers to account for the IGBT failures. The 4-leg topology, meanwhile, uses a specific 3D space vector PWM to handle vehicle requirements in terms of size (DC bus capacitors) and cost (IGBTs number). Experiments on an induction motor drive and simulations on an electric vehicle are carried-out using a European urban driving cycle to show that the proposed fault-tolerant control approach is effective and provides a simple configuration with high performance in terms of speed and torque responses. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Eugenics Past and Present: Remembering Buck v. Bell.

    Science.gov (United States)

    Berson, Michael J.; Cruz, Barbara

    2001-01-01

    Provides background information about the eugenics movement. Focuses on eugenics in the United States detailing the case, Buck v. Bell, and eugenics in Germany. Explores the present eugenic movement, focusing on "The Bell Curve," China's one child policy, and the use of eugenic sterilizations in the United States and Canada. Includes…

  9. "The Bell Curve" and Carrie Buck: Eugenics Revisited.

    Science.gov (United States)

    Smith, J. David

    1995-01-01

    The 1994 publication of "The Bell Curve" by R. Herrnstein and C. Murray is compared to other examples of eugenic principles, including the sterilization of "feebleminded" Carrie Buck, family degeneracy studies focusing on lower class Caucasian families, and other works that view the poorest and least educated members of society…

  10. Progressive decrement PWM algorithm for minimum mean square error inverter output voltage

    International Nuclear Information System (INIS)

    Ghaeb, J.A.; Smadi, M.A.; Ababneh, M.

    2011-01-01

    Highlights: → The main contribution of this work is to provide a better performance for the power inverter operation. → The proposed technique splits the determined original pulse-width of an inverter operation in to many pulses. → The new approach extends the central pulse and shrinks the exterior pulses. → This is leading to an inverter output cycle close to the sinusoidal form of fewer harmonics. - Abstract: The paper proposes two modulation techniques for the power inverter. These new techniques are named progressive decrement PWM algorithm (PDPA) and progressive increment PWM algorithm (PIPA). Both techniques take the determined original pulse-width of an inverter operation and split it to many pulses. In the PDPA technique, the largest width is given to the middle pulse and the width of the boundary pulses is reduced progressively starting from the first boundary-pulse toward the last boundary-pulse. In the PIPA technique, there is a gradual increment instead of decrement. The two techniques have been proved that it can maintain the original pulse-width of the inverter operation. The new approach PDPA extends the central pulse and shrinks the exterior pulses, leading to an inverter output cycle close to the sinusoidal form of fewer harmonic contents. Simulation results are performed to evaluate the performances of the proposed techniques: PDPA and PIPA and to compare them with the well known methods. The main contribution of the proposed PDPA technique is that it provides a better performance for the most harmonic orders compared to the well established sinusoidal PWM technique.

  11. Start Up Current Control of Buck-Boost Convertor-Fed Serial DC Motor

    Directory of Open Access Journals (Sweden)

    Yusuf SÖNMEZ

    2009-02-01

    Full Text Available Generally, DC motors are given preference for industrial applications such as electric locomotives, cranes, goods lifts. Because of they have high starting moment; they initially start with high current. This high start-up current must be decreased since it may damage windings of the motor and increases power consumption. It could be controlled by an appropriate driver system and controller. The nature of fuzzy logic control has adaptive characteristics that can achieve robust response to a system with uncertainty, parameter variation, and load disturbance. In this paper, fuzzy logic based control of start-up current of a Buck-Boost Converter fed serial DC motor is examined through computer simulation. In order to see the advantages of fuzzy logic control, classical PI control has applied to the same motor, under same circumstances and has been compared. C++ Builder software has been used for the simulation. According to the simulation results, plainly, fuzzy logic control has stronger responses than classical PI control and uses lower current at starting moment.

  12. Synchronised PWM Schemes for Three-level Inverters with Zero Common-mode Voltage

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    This paper presents results of analysis and comparison of novel synchronised schemes of pulsewidth modulation (PWM), applied to three-level voltage source inverters with control algorithms providing elimination of the common-mode voltage. The proposed approach is based on a new strategy of digital...

  13. Full-Circle Resolver-to-Linear-Analog Converter

    Science.gov (United States)

    Alhorn, Dean C.; Smith, Dennis A.; Howard, David E.

    2005-01-01

    A circuit generates sinusoidal excitation signals for a shaft-angle resolver and, like the arctangent circuit described in the preceding article, generates an analog voltage proportional to the shaft angle. The disadvantages of the circuit described in the preceding article arise from the fact that it must be made from precise analog subcircuits, including a functional block capable of implementing some trigonometric identities; this circuitry tends to be expensive, sensitive to noise, and susceptible to errors caused by temperature-induced drifts and imprecise matching of gains and phases. These disadvantages are overcome by the design of the present circuit. The present circuit (see figure) includes an excitation circuit, which generates signals Ksin(Omega(t)) and Kcos(Omega(t)) [where K is an amplitude, Omega denotes 2(pi)x a carrier frequency (the design value of which is 10 kHz), and t denotes time]. These signals are applied to the excitation terminals of a shaft-angle resolver, causing the resolver to put out signals C sin(Omega(t)-Theta) and C cos(Omega(t)-Theta). The cosine excitation signal and the cosine resolver output signal are processed through inverting comparator circuits, which are configured to function as inverting squarers, to obtain logic-level or square-wave signals .-LL[cos(Omega(t)] and -LL[cos(Omega(t)-Theta)], respectively. These signals are fed as inputs to a block containing digital logic circuits that effectively measure the phase difference (which equals Theta between the two logic-level signals). The output of this block is a pulse-width-modulated signal, PWM(Theta), the time-averaged value of which ranges from 0 to 5 VDC as Theta ranges from .180 to +180deg. PWM(Theta) is fed to a block of amplifying and level-shifting circuitry, which converts the input PWM waveform to an output waveform that switches between precise reference voltage levels of +10 and -10 V. This waveform is processed by a two-pole, low-pass filter, which removes

  14. Three port converters used as interface in photovoltaic energy systems

    Directory of Open Access Journals (Sweden)

    Sarab Al-Chlaihawi

    2018-04-01

    Full Text Available The aim of this paper is to derive and study a full-bridge three-port converter. Based on the standard design of full-bridge converter, we have modeled and derived a three port converter. The three port converter can be used in renewable energy scenarios, such as solar cells or wind turbines connected to the input port. The input can be taken from two-ports simultaneously or from one port at a time. In order to balance the power mismatch between the input port and load port, the batteries are attached to the third port, to ensure there are no discrepancies in the power generated at the input and power demand at the load. In order to ensure isolation and reduced voltage stress on the switches, a high frequency transformer is also used in the design. The overall design contains four switches, and four diodes. MOSFETs are the strongest candidate for the switches owing to their high switching speed, lower losses and high resistance to higher voltage. Moreover, a buck-boost structure is modeled in order to ensure that it can work for a wide variety of different applications by adjusting the duty cycle of the switches properly. To minimize the switching losses in the converter, Zero-Voltage Switching (ZVS is also achievable in the modeled system.

  15. PV power system using hybrid converter for LED indictor applications

    International Nuclear Information System (INIS)

    Tseng, Sheng-Yu; Wang, Hung-Yuan; Chen, Chien-Chih

    2013-01-01

    Highlights: • This paper presents a LED indictor driving circuit with a PV arrays as its power source. • The perturb-and-observe method is adopted to extract the maximum power of PV arrays. • The proposed circuit structure has a less component counts and higher conversion efficiency. • A prototype of LED indictor driving circuit has been implemented to verify its feasibility. • The proposed hybrid converter is suitable for LED inductor applications. - Abstract: This paper presents a LED indictor driving circuit with a PV arrays as its power source. The LED indictor driving circuit includes battery charger and discharger (LED driving circuit). In this research, buck converter is used as a charger, and forward converter with active clamp circuit is adopted as a discharger to drive the LED indictor. Their circuit structures use switch integration technique to simplify them and to form the proposed hybrid converter, which has a less component counts, lighter weight, smaller size, and higher conversion efficiency. Moreover, the proposed hybrid converter uses a perturb-and-observe method to extract the maximum power from PV arrays. Finally, a prototype of an LED indictor driving circuit with output voltage of 10 V and output power of 20 W has been implemented to verify its feasibility. It is suitable for the LED inductor applications

  16. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence......, it has enhanced buck-boost functionality and low output voltage distortions compared to the traditional Z-source inverter; it has continuous input current which reduces the source stress and inverter noise; it also contains two built-in capacitors which can block the DC current in the transformer...... windings thus preventing the core from saturation; lowers the voltage stresses and power losses of inverter switches and reduces the sizes of filtering devices and as well as obtains better output performance compared to the original two-level Z-source inverters. A phase disposition pulse width modulation...

  17. Analog Fixed Maximum Power Point Control for a PWM Step-downConverter for Water Pumping Installations

    DEFF Research Database (Denmark)

    Beltran, H.; Perez, E.; Chen, Zhe

    2009-01-01

    This paper describes a Fixed Maximum Power Point analog control used in a step-down Pulse Width Modulated power converter. The DC/DC converter drives a DC motor used in small water pumping installations, without any electric storage device. The power supply is provided by PV panels working around....... The proposed Optimal Power Point fix voltage control system is analyzed in comparison to other complex controls....... their maximum power point, with a fixed operating voltage value. The control circuit implementation is not only simple and cheap, but also robust and reliable. System protections and adjustments are also proposed. Simulations and hardware are reported in the paper for a 150W water pumping application system...

  18. Coconut milk - citrate as extender for West African dwarf buck ...

    African Journals Online (AJOL)

    JTEkanem

    healthy buck certified free of obvious andrological defects. Eight trials of .... EE probe was lubricated with VaselineR before insertion into the ... A descriptive analysis was performed by calculating ..... assistance of Mr. P. I. Odili, laboratory.

  19. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2015-01-01

    converter topology based on a symmetrical half bridge circuit is proposed to decouple the ripple power so that balanced instantaneous power flow is assured between source and load, and the required dc-link capacitance can be dramatically reduced. For proper closed-loop regulation, the small signal modeling...... is therefore very sensitive to step load changes. Comprehensive simulation results and experimental results are presented to show the effectiveness of the proposed circuit and control algorithm....

  20. Design of a high efficiency 30 kW boost composite converter

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyeokjin [Univ. of Colorado, Boulder, CO (United States); Chen, Hua [Univ. of Colorado, Boulder, CO (United States); Maksimovic, Dragan [Univ. of Colorado, Boulder, CO (United States); Erickson, Robert W. [Univ. of Colorado, Boulder, CO (United States)

    2015-09-20

    An experimental 30 kW boost composite converter is described in this paper. The composite converter architecture, which consists of a buck module, a boost module, and a dual active bridge module that operates as a DC transformer (DCX), leads to substantial reductions in losses at partial power points, and to significant improvements in weighted efficiency in applications that require wide variations in power and conversion ratio. A comprehensive loss model is developed, accounting for semiconductor conduction and switching losses, capacitor losses, as well as dc and ac losses in magnetic components. Based on the developed loss model, the module and system designs are optimized to maximize efficiency at a 50% power point. Experimental results for the 30 kW prototype demonstrate 98.5%peak efficiency, very high efficiency over wide ranges of power and voltage conversion ratios, as well as excellent agreements between model predictions and measured efficiency curves.

  1. PV Power-Generation System with a Phase-Shift PWM Technique for High Step-Up Voltage Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-01-01

    Full Text Available A PV power-generation system with a phase-shift pulse-width modulation (PWM technique for high step-up voltage applications is proposed. The proposed power-generation system consists of two stages. In the input stage, all power switches of the full-bridge converter with phase-shift technique can be operated with zero-current switching (ZCS at turn-on or turn-off transition. Hence, the switching losses of the power switches can be reduced. Then, in the DC output stage, a voltage-doubler circuit is used to boost a high dc-link bus voltage. To supply a utility power, a dc/ac inverter is connected to induce a sinusoidal source. In order to draw a maximum power from PV arrays source, a microcontroller is incorporated with the perturbation and observation method to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In this study, a full load power of 300 W prototype has been built. Experimental results are presented to verify the performance and feasibility of the proposed PV power-generation system.

  2. Math Model and Calculation Analysis of Inter-harmonic of Double PWM Speed Control System in Distribution Network

    Directory of Open Access Journals (Sweden)

    Yang Wen-Huan

    2014-11-01

    Full Text Available Aiming at the problem that the distribution network voltage will fluctuate because of the inter-harmonic currents injected into the network by double PWM speed control system when regulating the speed of the asynchronous motor, we established the inter-harmonic current math model of double PWM speed control system according to switching function based on a real bridge crane. The distribution law of the inter-harmonic is got by calculating the grid-side currents and their spectrum while letting the motor run at different quadrants and frequencies. The result which is verified by simulation and experiment shows that the content of the inter harmonic currents is more than that of harmonic currents in double PWM speed control system, the frequency of the inter harmonics of the grid-side current mainly focus on the scope lower than the fundamental frequency, and when the motor runs at low frequencies, the THD of the grid-side current is high. The result has verified the reason why the voltage of a bridge crane distribution system of a deepwater port in Shanghai flickers.

  3. Effect of body condition score of does and use of bucks subjected to added artificial light on estrus response of Alpine goats.

    Science.gov (United States)

    Rivas-Muñoz, Raymundo; Carrillo, Evaristo; Rodriguez-Martinez, Rafael; Leyva, Carlos; Mellado, Miguel; Véliz, Francisco Gerardo

    2010-08-01

    The effects of body condition score of does and exposure to sexually active bucks after exposure to long-day artificial photoperiod were examined in mature anovulatory French Alpine goat in Northern Mexico. In June, goats in good (2.3 +/- 0.2, scale 1 to 4; n = 10) or poor (1.6 +/- 0.3; n = 10) body condition were exposed during 15 day to sexually active bucks, which had been exposed to long photoperiod (16:8-h light-dark cycle, starting in December). A third group of goats in good body condition was exposed to bucks kept under the natural photoperiod of this region (26 degrees N). All goats in good body condition exposed to bucks treated with prolonged photoperiod exhibited estrus behavior, whereas only 50% of the does in poor body condition showed estrous behavior during the 15-day buck exposure. None of the does in good body condition showed estrus when exposed to bucks under natural photoperiod. These results revealed that a good body condition is required for maximum estrus response in anestrous Alpine goats and that exposure of bucks to long photoperiod in winter is essential for an adequate stimulus to reestablish estrus cycles in anovulatory Alpine does in Northern Mexico.

  4. An analytical inductor design procedure for three-phase PWM converters in power factor correction applications

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Niroumand, Farideh Javidi; Haase, Frerk

    2015-01-01

    This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyze...... to calculate the core loss in the PFC application. To investigate the impact of the dc link voltage level, two inductors for different dc voltage levels are designed and the results are compared.......This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyzes...... circuit is used to provide the inductor current harmonic spectrum. Therefore, using the harmonic spectrum, the low and high frequency copper losses are calculated. The high frequency minor B-H loops in one switching cycle are also analyzed. Then, the loss map provided by the measurement setup is used...

  5. Designing and Testing Composite Energy Storage Systems for Regulating the Outputs of Linear Wave Energy Converters

    Directory of Open Access Journals (Sweden)

    Zanxiang Nie

    2017-01-01

    Full Text Available Linear wave energy converters generate intrinsically intermittent power with variable frequency and amplitude. A composite energy storage system consisting of batteries and super capacitors has been developed and controlled by buck-boost converters. The purpose of the composite energy storage system is to handle the fluctuations and intermittent characteristics of the renewable source, and hence provide a steady output power. Linear wave energy converters working in conjunction with a system composed of various energy storage devices, is considered as a microsystem, which can function in a stand-alone or a grid connected mode. Simulation results have shown that by applying a boost H-bridge and a composite energy storage system more power could be extracted from linear wave energy converters. Simulation results have shown that the super capacitors charge and discharge often to handle the frequent power fluctuations, and the batteries charge and discharge slowly for handling the intermittent power of wave energy converters. Hardware systems have been constructed to control the linear wave energy converter and the composite energy storage system. The performance of the composite energy storage system has been verified in experiments by using electronics-based wave energy emulators.

  6. Utilization of Nonlinear Converters for Audio Amplification

    DEFF Research Database (Denmark)

    Iversen, Niels; Birch, Thomas; Knott, Arnold

    2012-01-01

    Class D ampliers ts the automotive demands quite well. The traditional buck-based amplier has reduced both the cost and size of ampliers. However the buck topology is not without its limitations. The maximum peak AC output voltage produced by the power stage is only equal the supply voltage...

  7. Temperature prediction in high speed bone grinding using motor PWM signal.

    Science.gov (United States)

    Tai, Bruce L; Zhang, Lihui; Wang, Anthony C; Sullivan, Stephen; Wang, Guangjun; Shih, Albert J

    2013-10-01

    This research explores the feasibility of using motor electrical feedback to estimate temperature rise during a surgical bone grinding procedure. High-speed bone grinding is often used during skull base neurosurgery to remove cranial bone and approach skull base tumors through the nasal corridor. Grinding-induced heat could propagate and potentially injure surrounding nerves and arteries, and therefore, predicting the temperature in the grinding region would benefit neurosurgeons during the operation. High-speed electric motors are controlled by pulse-width-modulation (PWM) to alter the current input and thus maintain the rotational speed. Assuming full mechanical to thermal power conversion in the grinding process, PWM can be used as feedback for heat generation and temperature prediction. In this study, the conversion model was established from experiments under a variety of grinding conditions and an inverse heat transfer method to determine heat flux. Given a constant rotational speed, the heat conversion was represented by a linear function, and could predict temperature from the experimental data with less than 20% errors. Such results support the advance of this technology for practical application. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Development and optimization of a matrix converter supplying an electronic ballast - UV lamp system for water sterilization

    Science.gov (United States)

    Bokhtache, Aicha Aissa; Zegaoui, Abdallah; Aillerie, Michel; Djahbar, Abdelkader; Hemici, Kheira

    2018-05-01

    Electronic ballasts dedicated to discharge lamps allow improving the quality of radiation by operating at high frequency. In the present work, the use of a single-phase direct converter with a matrix structure for supplying a low-pressure mercury-argon UVC lamp for water sterilization is proposed. The structure of the converter is based on two switching cells allowing the realization of a fully controllable bidirectional switches. The advantages of such a matrix topology include the delivered of a sinusoidal waveform current with a controllable power factor close to unity, variable in amplitude and frequency. In order to obtain the desired amplitude and frequency, a PWM control was associated in the current realization. Finally, a linear adjustment of the lamp arc current was warranted by using of a PI regulator.

  9. Unified Subharmonic Oscillation Conditions for Peak or Average Current Mode Control

    OpenAIRE

    Fang, Chung-Chieh

    2013-01-01

    This paper is an extension of the author's recent research in which only buck converters were analyzed. Similar analysis can be equally applied to other types of converters. In this paper, a unified model is proposed for buck, boost, and buck-boost converters under peak or average current mode control to predict the occurrence of subharmonic oscillation. Based on the unified model, the associated stability conditions are derived in closed forms. The same stability condition can be applied to ...

  10. Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Gaubert, Jean-Paul; Krim, Fateh

    2010-01-01

    This paper is concerned with the design and implementation of current control of three-phase PWM rectifier based on predictive control strategy. The proposed predictive current control technique operates with constant switching frequency, using space-vector modulation (SVM). The main goal of the designed current control scheme is to maintain the dc-bus voltage at the required level and to achieve the unity power factor (UPF) operation of the converter. For this purpose, two predictive current control algorithms, in the sense of deadbeat control, are developed for direct controlling input current vector of the converter in the stationary α-β and rotating d-q reference frame, respectively. For both predictive current control algorithms, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of both tracking errors of current vector components at the end of the switching period, is computed and applied during a predefined switching period by means of SVM. The main advantages of the proposed predictive current control are that no need to use hysteresis comparators or PI controllers in current control loops, and constant switching frequency. Finally, the developed predictive current control algorithms were tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance in steady and transient states, and verify the validity of the proposed predictive current control which is compared to other control strategies.

  11. A New Method to Implement Resampled Uniform PWM Suitable for Distributed Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Huang, Shaojun; Mathe, Laszlo; Teodorescu, Remus

    2013-01-01

    Two existing methods to implement resampling modulation technique for modular multilevel converter (MMC) (the sampling frequency is a multiple of the carrier frequency) are: the software solution (using a microcontroller) and the hardware solution (using FPGA). The former has a certain level...

  12. Studi Komparasi Fungsi Keanggotaan Fuzzy sebagai Kontroler Bidirectional DC-DC Converter pada Sistem Penyimpan Energi

    Directory of Open Access Journals (Sweden)

    Eka Prasetyono

    2015-09-01

    Full Text Available Bidirectional DC-DC converter is needed in the energy storage system. The converter topology used in this paper was a non-isolated bidirectional DC-DC buck-boost converter. This converter worked in two ways, which the charging mode stored energy into battery when load current was less than nominal main DC current (set point and discharging mode transferred energy from battery to the load when its current exceeded set point value. Both of these modes worked automatically according to the load current. The charging and discharging currents were controlled by fuzzy logic controller which was implemented on microcontroller ARM Cortex-M4F STM32F407VG. This paper compares two types of fuzzy membership function (triangular and sigmoid in controlling bidirectional DC-DC converter. The results showed that fuzzy logic controller with triangle membership function and sigmoid as control bidirectional DC-DC converter had no significant different response, both had an average error for charging and discharging process under 4% with ripple current on the main DC bus around 0.5%. The computing time of program for fuzzy logic controller with triangular membership functions had 19.01% faster than sigmoid, and fuzzy logic computation time on a microcontroller with hardware floating point was 60% faster than software floating point.

  13. Small-Signal Analysis of Single-Phase and Three-phase DC/AC and AC/DC PWM Converters with the Frequency-Shift Technique

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Aquila, A. Dell’; Liserre, Marco

    2004-01-01

    of dc/dc converters via a 50 Hz frequency-shift. The input admittance is calculated and measured for two study examples (a three-phase active rectifier and a single-phase photovoltaic inverter). These examples show that the purpose of a well designed controller for grid-connected converters......A systematic approach to study dc/ac and ac/dc converters without the use of synchronous transformation is proposed. The use of a frequency-shift technique allows a straightforward analysis of single-phase and three-phase systems. The study of dc/ac and of ac/dc converters is reported to the study...... is to minimize the input admittance in order to make the grid converter more robust to grid disturbance....

  14. Operational limits of a three level neutral point clamped converter used for controlling a hybrid energy storage system

    International Nuclear Information System (INIS)

    Etxeberria, A.; Vechiu, I.; Camblong, H.; Kreckelbergh, S.; Bacha, S.

    2014-01-01

    Highlights: • The control of a hybrid storage system using a Three Level NPC converter is analysed. • A sinusoidal PWM with an offset injection is used to control the storage system. • The operation of the selected converter is analysed in its entire operation range. • The operational limits of the Three Level NPC converter are defined. - Abstract: This work analyses the use of a Three-Level Neutral Point Clamped (3LNPC) converter to control the power flow of a Hybrid Energy Storage System (HESS) and at the same time interconnect it with the common AC bus of a microgrid. Nowadays there is not any storage technology capable of offering a high energy storage capacity, a high power capacity and a fast response at the same time. Therefore, the necessity of hybridising more than one storage technology is a widely accepted idea in order to satisfy the mentioned requirements. This work shows how the operational limits of the 3LNPC converter can be calculated and integrated in a control structure to facilitate an optimal use of the HESS according to the rules fixed by the user

  15. Reproductive Parameters of the West African Dwarf Bucks Raised in ...

    African Journals Online (AJOL)

    Reproductive samples (scrotal circumference, testicular density, scrotal weight, left and right testicular weights, left and right tunica weights, left and right testicular length, left and right caput epididymal weights, left and right corpus epididymal weights, left and right caudal epididymal weights) from the bucks were collected ...

  16. Tipe Dry Cell dan Wet Cell berdimensi 80 x 80 mm dengan Penambahan PWM E-3 FF (1 kHz

    Directory of Open Access Journals (Sweden)

    Yanur Arzaqa Ghiffari

    2013-09-01

    Full Text Available Ketersediaan bahan bakar minyak semakin terbatas dan hasil pembakarannya berdampak pada pencemaran lingkungan, salah satu solusinya dengan memanfaatkan gas HHO pada kendaraan bermotor. Penelitian dengan sistem direct connection, temperatur mencapai lebih dari 90oC menyebabkan  generator HHO menjadi rusak dan meleleh, maka penelitian ini menambahan alat untuk mengkontrol besarnya arus, frekuensi, dan duty cycle. Pengembangan generator HHO menggunakan tipe kering (dry cell dan tipe basah (wet cell dengan penambahan PWM (Pulse Width Modulation E-3 Fixed Frequency 1 kHz divariasikan berupa duty cycle: 20%, 40%, 60%, 80%  dan direct connection. Pengujian dilakukan di Laboratorium Teknik Pembakaran dan Bahan Bakar - Teknik Mesin ITS.  Dari hasil penelitian didapatkan karakteristik unjuk kerja terbaik pada kedua tipe generator HHO dengan penambahan PWM. Nilai arus dan tegangan lebih stabil dibandingkan dengan tanpa penambahan PWM (direct connection, namun arus cenderung meningkat seiring dengan kenaikan temperatur mencapai 70oC. Efisiensi terbaik pada generator tipe wet dengan duty cycle 80%,  yaitu 27,7 %.

  17. Applying Buck Converter in Jiuquan Solar Photovoltaic Power Generation%Buck变换器在酒泉太阳能光伏发电中的应用

    Institute of Scientific and Technical Information of China (English)

    秦天像

    2011-01-01

    Solar photovoltaic effect, the output voltage is energy, as a new, easily subject not stable. The research presented to seasonal variation, diurnal alternating in this paper shows Buck converter, the perturbation method, and the MPPT control strategy can be applied to the Jiuquan solar photovoltaic power generation, which can make the output of an equivalent impedance circuit with PV battery output impedance, the photovoltaic array in any condition to obtain the maximum power output, the advantages of tracking maximum power. Simulation results show that MPPT the feasibility of the control strategy, the proposed method can effectively improve the stability of the output voltage.%太阳能光伏发电作为一种新能源,易受季节变化、昼夜交替的影响,因此其输出电压很不稳定.鉴于此,本文采用Buck变换器,采用扰动观察法的MPPT控制策略,可应用到酒泉的太阳能光伏发电中,可使得输出电路的等效阻抗跟随光伏电池的输出阻抗,使光伏阵列在任何条件下获得最大功率输出,跟踪最大功率的优点.仿真表明,MPPT(最大功率跟踪)控制策略的可行性,该方法有效地提高了输出电压的稳定性.

  18. Pulsewidth modulated DC-to-DC power conversion circuits, dynamics, and control designs

    CERN Document Server

    Choi, Byungcho

    2013-01-01

    This is the definitive reference for anyone involved in pulsewidth modulated DC-to-DC power conversion Pulsewidth Modulated DC-to-DC Power Conversion: Circuits, Dynamics, and Control Designs provides engineers, researchers, and students in the power electronics field with comprehensive and complete guidance to understanding pulsewidth modulated (PWM) DC-to-DC power converters. Presented in three parts, the book addresses the circuitry and operation of PWM DC-to-DC converters and their dynamic characteristics, along with in-depth discussions of control design of PWM DC-to

  19. A PWM Controller of a Full Bridge Single-Phase Synchronous Inverter for Micro-Grid System

    Science.gov (United States)

    Rahman, Tawfikur; Motakabber, S. M. A.; Ibrahimy, M. I.; Raghib, Aliza ‘Aini Binti Md Ralib@ Md

    2017-12-01

    Nowadays, microgrid system technology is becoming popular for small area power management systems. It is essential to be less harmonic-distortion and high efficiency of the inverter for microgrid applications. Pulse width modulation (PWM) controller is a conventional switching control technique which is suitable to use in the microgrid connected power inverter system. The control method and algorithm of this technique are challenging, and different approaches are required to avoid the complexity for a customized solution of the microgrid application. This paper proposes a comparative analysis of different controller and their operational methods. A PWM controller is used to reduce the ripple voltage noise while a continuous current mode provides a small output ripple which gives steady-state error as zero on fundamental and cutoff frequency. To reduce the ripple current, higher frequency harmonic distortion, switching loss and phase noise, LC low pass filter is used on either side of input and output terminals. The proposed inverter is designed by MATLAB 2016a simulation software. A balanced load resistance (RL = 20.5 Ω) of star configuration and a dual input DC voltage of ± 35V are considered. In this design, the circuit parameters, the fundamental frequency of 50 Hz, the PWM duty cycle of 95%, the cutoff frequency of the switching controller of 33 kHz are considered. The inverter in this paper exhibits THD of 0.44% and overall efficiency approximately of 98%. The proposed inverter is expected to be suitable for microgrid applications.

  20. Utilization of non-linear converters for audio amplification

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Birch, Thomas; Knott, Arnold

    2012-01-01

    Class D amplifiers fits the automotive demands quite well. The traditional buck-based amplifier has reduced both the cost and size of amplifiers. However the buck topology is not without its limitations. The maximum peak AC output voltage produced by the power stage is only equal the supply voltage...

  1. Highly Sensitive Temperature Sensors Based on Fiber-Optic PWM and Capacitance Variation Using Thermochromic Sensing Membrane

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-07-01

    Full Text Available In this paper, we propose a temperature/thermal sensor that contains a Rhodamine-B sensing membrane. We applied two different sensing methods, namely, fiber-optic pulse width modulation (PWM and an interdigitated capacitor (IDC-based temperature sensor to measure the temperature from 5 °C to 100 °C. To the best of our knowledge, the fiber-optic PWM-based temperature sensor is reported for the first time in this study. The proposed fiber-optic PWM temperature sensor has good sensing ability; its sensitivity is ~3.733 mV/°C. The designed temperature-sensing system offers stable sensing responses over a wide dynamic range, good reproducibility properties with a relative standard deviation (RSD of ~0.021, and the capacity for a linear sensing response with a correlation coefficient of R2 ≈ 0.992 over a wide sensing range. In our study, we also developed an IDC temperature sensor that is based on the capacitance variation principle as the IDC sensing element is heated. We compared the performance of the proposed temperature-sensing systems with different fiber-optic temperature sensors (which are based on the fiber-optic wavelength shift method, the long grating fiber-optic Sagnac loop, and probe type fiber-optics in terms of sensitivity, dynamic range, and linearity. We observed that the proposed sensing systems have better sensing performance than the above-mentioned sensing system.

  2. Geologic Controls of Sand Boil Formation at Buck Chute, Mississippi

    Science.gov (United States)

    2017-06-30

    26 5.1 Electrical resistivity tomography ...construction at Buck Chute in preparation to the 2011 Flood. ERDC/GSL TR-17-12 21 4 Methods 4.1 Electrical resistivity tomography The resistivity ...could contribute to sand boil formation is missed. Electrical Resistivity Tomography (ERT) is a subsurface investigation method that combines the

  3. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  4. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    Science.gov (United States)

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  5. Multiple low frequency dual reference PWM control of a grid connected photovoltaic three phase NPC inverter with DC/DC boost converter

    Directory of Open Access Journals (Sweden)

    Mechouma Rabiaa

    2014-01-01

    Full Text Available In recent years, power demand of industrial applications has increased significantly reaching some megawatts. The use of multilevel converters for applications of medium and high powers is proposed as a solution to drawback semiconductor technology. A multilevel converter not only achieves high power ratings, but also enables the use of renewable energy sources. Renewable energy sources such as photovoltaic can be easily interfaced to a multilevel converter system for a high power application. This paper presents the simulation study in Matlab/Simulink of a grid connected photovoltaic three phase Neutral Point Clamped (NPC inverter with DC/DC boost converter for constant and variable solar radiation.

  6. The Way Women's Fight Against Patriarchal System: a Feminist Analysis Towards Pearl S. Buck's Imperial Woman

    OpenAIRE

    Wennyta

    2015-01-01

    This research is conducted to show that woman not always passive, weak or inferior side, but she can use her inferiority (from patriarchal point of view) as a tricky strategy to get the equality between men and women. It is described in Imperial Woman, where Yehonala succeeds in arranging many strategies inside the oppression from patriarchal system. In collecting the data, the writer conducts a library research. A novel by Pearl S. Buck, entitled Imperial Woman and also the biography of Buck...

  7. Analysis and Mitigation of Dead Time Harmonics in the Single-Phase Full-Bridge PWM Converters with Repetitive Controllers

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Wang, Huai

    2018-01-01

    In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot-through in voltage source converters during a switching period, the dead time is added either in the hardware driver circuits of the IGBTs or implemented in software in Pulse-Width Modul......In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot-through in voltage source converters during a switching period, the dead time is added either in the hardware driver circuits of the IGBTs or implemented in software in Pulse...

  8. A fully integrated, wide-load-range, high-power-conversion-efficiency switched capacitor DC-DC converter with adaptive bias comparator for ultra-low-power power management integrated circuit

    Science.gov (United States)

    Asano, Hiroki; Hirose, Tetsuya; Kojima, Yuta; Kuroki, Nobutaka; Numa, Masahiro

    2018-04-01

    In this paper, we present a wide-load-range switched-capacitor DC-DC buck converter with an adaptive bias comparator for ultra-low-power power management integrated circuit. The proposed converter is based on a conventional one and modified to operate in a wide load range by developing a load current monitor used in an adaptive bias comparator. Measurement results demonstrated that our proposed converter generates a 1.0 V output voltage from a 3.0 V input voltage at a load of up to 100 µA, which is 20 times higher than that of the conventional one. The power conversion efficiency was higher than 60% in the load range from 0.8 to 100 µA.

  9. Galvanically Isolated Quasi-Z-Source DC–DC Converter With a Novel ZVS and ZCS Technique

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Liivik, Liisa; Blaabjerg, Frede

    2015-01-01

    This paper focuses on the galvanically isolated quasi-Z-source dc-dc converter with a novel zero voltage and zero current switching technique. The unique feature of the impedance network lies in combining the buck-boost operation capability with the short- and open-circuit immunity of transistors......; at the same time, it can perform zero voltage and zero current switching on the primary side. The boundary conduction mode of the current in the second inductor of the quasi-Z-source network was used along with snubber capacitors in the two out of four transistors and a special control algorithm to achieve...

  10. Analysis and Controller Design of a Universal Bidirectional DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Kou-Bin Liu

    2016-06-01

    Full Text Available In this paper, first the operating principles of a non-isolated universal bidirectional DC-DC converter are studied and analyzed. The presented power converter is capable of operating in all power transferring directions in buck/boost modes. Zero voltage switching can be achieved for all the power switches through proper modulation strategy design, therefore, the presented converter can achieve high efficiency. To further improve the efficiency, the relationship between the phase-shift angle and the overall system efficiency is analyzed in detail, an adaptive phase-shift (APS control method which determines the phase-shift value between gating signals according to the load level is then proposed. As the modulation strategy is a software-based solution, there is no requirement for additional circuits, therefore, it can be implemented easily and instability and noise susceptibility problems can be reduced. To validate the correctness and the effectiveness of the proposed method, a 300 W prototyping circuit is implemented and tested. A low cost dsPIC33FJ16GS502 digital signal controller is adopted in this paper to realize the power flow control, DC-bus voltage regulation and APS control. According to the experimental results, a 12.2% efficiency improvement at light load and 4.0% efficiency improvement at half load can be achieved.

  11. Modeling and Analysis of Power Processing Systems (MAPPS). Volume 2: Appendices

    Science.gov (United States)

    Lee, F. C.; Radman, S.; Carter, R. A.; Wu, C. H.; Yu, Y.; Chang, R.

    1980-01-01

    The computer programs and derivations generated in support of the modeling and design optimization program are presented. Programs for the buck regulator, boost regulator, and buck-boost regulator are described. The computer program for the design optimization calculations is presented. Constraints for the boost and buck-boost converter were derived. Derivations of state-space equations and transfer functions are presented. Computer lists for the converters are presented, and the input parameters justified.

  12. Effect of metallurgical factors on the magnetic properties of non-oriented electrical steels under PWM excitation

    International Nuclear Information System (INIS)

    Tanaka, T.; Yashiki, H.; Takada, S.; Sasaki, T.

    1994-01-01

    Magnetic properties of non-oriented electrical steel sheets under PWM voltage excitation as well as those under sinusoidal excitation have been investigated from a metallurgical point of view. The core loss under PWM excitation is slightly larger than that under sinusoidal excitation. The induction dependence of the core loss difference between the two excitation conditions changes by changing Si content and grain size. The higher the induction, the larger the core loss difference of 0.2% Si steel with small grains. In the case of higher Si steels and 0.2% Si steel with large grain sizes, however, the core loss difference at inductions over 1.3 T decreases with increasing induction. At low induction levels the core loss difference has little relationship to the grain size. On the other hand, at high induction levels this difference decreases with increasing grain size. ((orig.))

  13. Modeling and reliability analysis of three phase z-source AC-AC converter

    Directory of Open Access Journals (Sweden)

    Prasad Hanuman

    2017-12-01

    Full Text Available This paper presents the small signal modeling using the state space averaging technique and reliability analysis of a three-phase z-source ac-ac converter. By controlling the shoot-through duty ratio, it can operate in buck-boost mode and maintain desired output voltage during voltage sag and surge condition. It has faster dynamic response and higher efficiency as compared to the traditional voltage regulator. Small signal analysis derives different control transfer functions and this leads to design a suitable controller for a closed loop system during supply voltage variation. The closed loop system of the converter with a PID controller eliminates the transients in output voltage and provides steady state regulated output. The proposed model designed in the RT-LAB and executed in a field programming gate array (FPGA-based real-time digital simulator at a fixedtime step of 10 μs and a constant switching frequency of 10 kHz. The simulator was developed using very high speed integrated circuit hardware description language (VHDL, making it versatile and moveable. Hardware-in-the-loop (HIL simulation results are presented to justify the MATLAB simulation results during supply voltage variation of the three phase z-source ac-ac converter. The reliability analysis has been applied to the converter to find out the failure rate of its different components.

  14. Semen characteristics and sexual hormones of Hy-Plus rabbit bucks influenced by a dietary multi-enzymes additive

    Directory of Open Access Journals (Sweden)

    H. Gado

    2015-06-01

    Full Text Available A total of 144 adult Hy-Plus rabbit bucks were randomly assigned into  four treatments of 36 replicates each, in a completely randomized design. Animals were fed ad libitum on basal diet supplemented with an enzyme complex (EZ at 0 (EZ0, 1 (EZ1, 3 (EZ3 and 5 (EZ5 kg/ton of feed. Total sperm count was higher (P<0.05 in EZ5 than in EZ0. Sperm motility increased with increasing levels of the EZ additive being lowest for EZ0 and highest for EZ5 rabbits (P<0.05. Percentage of dead sperm was higher (P<0.05 in EZ0 than in EZ5 rabbits. Rabbit bucks received the highest levele of EZ in their diet, had the shorter reaction time (22.31±3.17 sec; P<0.05,whereas EZ5 bucks took 43.56±5.89 sec to mount does for the first time after exposure. Blood testosterone, 17α-estradiol and progesterone levels were highest in EZ5 rabbits and lowest in EZ0 rabbits. Enzyme addition increased (P<0.05 sperm transit in estrus doe cervical mucus. Data suggested that the EZ additive in diets of  adult Hy-Plus rabbit bucks was effective to improve both semen characteristics and sexual drive.

  15. A Novel Multilevel DC - AC Converter from Green Energy Power Generators Using Step-Square Waving and PWM Technique

    Science.gov (United States)

    Fajingbesi, F. E.; Midi, N. S.; Khan, S.

    2017-06-01

    Green energy sources or renewable energy system generally utilize modular approach in their design. This sort of power sources are generally in DC form or in single cases AC. Due to high fluctuation in the natural origin of this energy (wind & solar) source they are stored as DC. DC power however are difficult to transfer over long distances hence DC to AC converters and storage system are very important in green energy system design. In this work we have designed a novel multilevel DC to AC converter that takes into account the modular design of green energy systems. A power conversion efficiency of 99% with reduced total harmonic distortion (THD) was recorded from our simulated system design.

  16. AC Small Signal Modeling of PWM Y-Source Converter by Circuit Averaging and Averaged Switch Modeling Technique

    DEFF Research Database (Denmark)

    Forouzesh, Mojtaba; Siwakoti, Yam Prasad; Blaabjerg, Frede

    2016-01-01

    Magnetically coupled Y-source impedance network is a newly proposed structure with versatile features intended for various power converter applications e.g. in the renewable energy technologies. The voltage gain of the Y-source impedance network rises exponentially as a function of turns ratio, w...

  17. Double Up Food Bucks program effects on SNAP recipients' fruit and vegetable purchases.

    Science.gov (United States)

    Steele-Adjognon, Marie; Weatherspoon, Dave

    2017-12-12

    To encourage the consumption of more fresh fruits and vegetables, the 2014 United Sates Farm Bill allocated funds to the Double Up Food Bucks Program. This program provided Supplemental Nutrition Assistance Program beneficiaries who spent $10 on fresh fruits and vegetables, in one transaction, with a $10 gift card exclusively for Michigan grown fresh fruits and vegetables. This study analyzes how fruit and vegetable expenditures, expenditure shares, variety and purchase decisions were affected by the initiation and conclusion, as well as any persistent effects of the program. Changes in fruit and vegetable purchase behaviors due to Double Up Food Bucks in a supermarket serving a low-income, predominantly Hispanic community in Detroit, Michigan were evaluated using a difference in difference fixed effects estimation strategy. We find that the Double Up Food Bucks program increased vegetable expenditures, fruit and vegetable expenditure shares, and variety of fruits and vegetables purchased but the effects were modest and not sustainable without the financial incentive. Fruit expenditures and the fruit and vegetable purchase decision were unaffected by the program. This study provides valuable insight on how a nutrition program influences a low-income, urban, Hispanic community's fruit and vegetable purchase behavior. Policy recommendations include either removing or lowering the purchase hurdle for incentive eligibility and dropping the Michigan grown requirement to better align with the customers' preferences for fresh fruits and vegetables.

  18. Improving fruit and vegetable consumption among low-income customers at farmers markets: Philly Food Bucks, Philadelphia, Pennsylvania, 2011.

    Science.gov (United States)

    Young, Candace R; Aquilante, Jennifer L; Solomon, Sara; Colby, Lisa; Kawinzi, Mukethe A; Uy, Nicky; Mallya, Giridhar

    2013-10-03

    We evaluated whether Philly Food Bucks, a bonus incentive program at farmers markets, is associated with increased fruit and vegetable consumption and Supplemental Nutrition Assistance Program (SNAP) sales at farmers markets in low-income areas. A convenience sample of 662 customers at 22 farmers markets in low-income neighborhoods in Philadelphia, Pennsylvania, was surveyed via face-to-face interviews. Questions addressed shopping characteristics, self-reported change in fruit and vegetable consumption, whether customers tried new fruits or vegetables, use of Philly Food Bucks, and demographic information. Market-level SNAP sales and Philly Food Bucks redemption data were also collected to monitor sales patterns. Philly Food Bucks users were significantly more likely than nonusers to report increasing fruit and vegetable consumption (OR, 2.4; 95% CI, 1.6-3.7; P < .001) and to report trying new fruits or vegetables (OR 1.8; 95% CI, 1.2-2.7; P = .006). At the market level, average SNAP sales more than doubled at farmers markets in low-income areas in the first 2 years of the Philly Food Bucks program. At the city's largest farmers market in a low-income area, the program was associated with an almost 5-fold higher increase in annual SNAP sales compared with baseline. Results from this study demonstrate that a bonus incentive program tied to SNAP was associated with self-reported increases in fruit and vegetable consumption and increased SNAP sales at participating farmers markets in low-income communities. More research is warranted to evaluate the long-term impact of bonus incentives on farmers market use, dietary behaviors, and health outcomes.

  19. A Comprehensive Analysis and Hardware Implementation of Control Strategies for High Output Voltage DC-DC Boost Power Converter

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2017-01-01

    Full Text Available Classical DC-DC converters used in high voltage direct current (HVDC power transmission systems, lack in terms of efficiency, reduced transfer gain and increased cost with sensor (voltage/current numbers. Besides, the internal self-parasitic behavior of the power components reduces the output voltage and efficiency of classical HV converters. This paper deals with extra high-voltage (EHV dc-dc boost converter by the application of voltage-lift technique to overcome the aforementioned deficiencies. The control strategy is based on classical proportional-integral (P-I and fuzzy logic closed-loop controller to get high and stable output voltage. Complete hardware prototype of EHV is implemented and experimental tasks are carried out with digital signal processor (DSP TMS320F2812. The control algorithms P-I, fuzzy logic and the pulse-width modulation (PWM signals for N-channel MOSFET device are performed by the DSP. The experimental results provided show good conformity with developed hypothetical predictions. Additionally, the presented study confirms that the fuzzy logic controller provides better performance than classical P-I controller under different perturbation conditions.

  20. Aalborg Inverter - A new type of “Buck in Buck, Boost in Boost” Grid-tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Blaabjerg, Frede

    2013-01-01

    This paper presents a new family of high efficiency DC/AC grid-tied inverter with a wide variation of input DC voltage. It is a kind of “Boost in Boost, Buck in Buck” inverter, meaning that only one power stage works at the high frequency to achieve the minimum switching loss. Furthermore......, the minimum filtering inductance in the power loop is achieved to reduce the conduction power loss whether in “Boost” or “Buck” mode. In theory, it can achieve higher efficiency than other inverters under the same condition of input DC voltage. The principle of operation is fully illustrated through...... the analysis on the equivalent circuits of a “three-level” single-phase inverter. Simulations show it has good control performance....

  1. Multi-cell DC-DC converters : modelling, analysis and control

    International Nuclear Information System (INIS)

    Feki, M.; El Aroudi, A.; Robert, B.G.M.

    2011-01-01

    This paper is devoted to modeling of a two-cell DC/DC buck converter, to the analysis of its behavior and to the design of control methods that yield to improve its performances. Various numerical simulations and dynamical aspects of this system are illustrated in the time domain and in the parameter space. Without control, the system may present many undesirable behaviors such as sub-harmonics and chaotic oscillations. The proposed controllers are able to widen the stability range of the system. Optimum values of parameters giving rise to fast response while maintaining stable periodic behavior are given in closed form. However, it is detected that in a certain region of the parameter space, the stabilized periodic orbit may coexist with a chaotic attractor. Boundary between basins of attraction are obtained by means of numerical simulations.

  2. Six-Phase Vehicular Drive with Renewable DC Sources and Hybrid PWM Control of Four Inverters

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Ermuratskii, Vladimir; Blaabjerg, Frede

    2015-01-01

    The paper presents results of research of quad-inverter-based automotive system with combined scheme of PWM control of inverters, supplied by two renewable dc sources (by fuel cells and by battery). It has been shown, that hybrid switching techniques can be used successfully for control of vehicle...

  3. Design and Simulation to Composite PI Controller on the Stratospheric Airship

    OpenAIRE

    Kangwen Sun; Ming Zhu; Bojin Qi; Xiaoming Chen

    2014-01-01

    In view of the stratospheric airship application requirements on energy storage and management system, based on the topology of DC/DC converter main circuit, the composite PI controller is designed to realize respective control with the Boost mode and Buck mode. Furthermore, limit stop integration method is proposed to achieve a buck-boost complex DC/DC converter boost with effective switching buck. Then, with the MATLAB Control System Toolbox design model, the composite PI controller design ...

  4. Comparative Evaluation of Pulsewidth Modulation Strategies for Z-Source Neutral-Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Wong, C.P.

    2007-01-01

    modulation (PWM) strategies for controlling the Z-source NPC inverter. While developing the PWM techniques, attention has been devoted to carefully derive them from a common generic basis for improved portability, easier implementation, and most importantly, assisting readers in understanding all concepts......Z-source neutral-point-clamped (NPC) inverter has recently been proposed as an alternative three-level buck-boost power conversion solution with an improved output waveform quality. In principle, the designed Z-source inverter functions by selectively "shooting through" its power sources, coupled...... to the inverter using two unique Z-source impedance networks, to boost the inverter three-level output waveform. Proper modulation of the new inverter would therefore require careful integration of the selective shoot-through process to the basic switching concepts to achieve maximal voltage-boost, minimal...

  5. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng

    2007-01-01

    This paper presents the careful integration of a newly proposed Z-source topological concept to the basic neutral-point-clamped (NPC) inverter topology for designing a three-level inverter with both voltage-buck and voltage-boost capabilities. The designed Z-source NPC inverter uses two unique X......-shaped inductance-capacitance (LC) impedance networks that are connected between two isolated dc input power sources and its inverter circuitry for boosting its AC output voltage. Through the design of an appropriate pulsewidth-modulation (PWM) algorithm, the two impedance networks can be short......-circuited sequentially (without shooting through the inverter full DC link) for implementing the ldquonearest-three-vectorrdquo modulation principle with minimized harmonic distortion and device commutations per half carrier cycle while performing voltage boosting. With only a slight modification to the inverter PWM...

  6. Distributed control system for parallel-connected DC boost converters

    Science.gov (United States)

    Goldsmith, Steven

    2017-08-15

    The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

  7. Single-phase to three-phase converter system of high quality for rural applications and distributed generation; Sistema conversor mono-trifasico de alta qualidade para aplicacoes rurais e de geracao distribuida

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Ricardo Q.; Pomilio, Jose A. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Eletrica e de Computacao], e-mail: ricardom@dsce.fee.unicamp.br; Buso, Simone [Universidade de Padova, Padua (Italy). Dept. de Engenharia da Informacao], e-mail: simone.buso@dei.unipd.it

    2004-07-01

    This paper describes a line-interactive single-phase to three-phase converter. The typical application is in rural areas supplied by the single-wire with earth return. The traditional objective of feeding a three-phase induction motor is not anymore the main concern for such conversion. Due to the evolution of the agro business, some of the local load (as electronic power converters, computers, communication equipment, etc.) requires high quality power, intended as sinusoidal, symmetrical and balanced three-phase voltage. Additionally, to maximize the power got from the feeder, the system provides a unitary power factor to the feeder. A three-phase PWM converter is used for this purpose. The power converter does not process all the load power, as in the conventional solutions, but only the fraction necessary to regulate the three-phase bus voltage. The control strategy, design highlights and experimental results are presented. (author)

  8. Development of ATC for High Speed and High Density Commuter Line

    Science.gov (United States)

    Okutani, Tamio; Nakamura, Nobuyuki; Araki, Hisato; Irie, Shouji; Osa, Hiroki; Sano, Minoru; Ikeda, Keigo; Ozawa, Hiroyuki

    A new ATC (Automatic Train Control) system has been developed with solutions to realize short train headway by assured braking utilizing digital data transmission via rails; the digital data for the ATP (Automatic Train Protection) function; and to achieve EMC features for both AC and DC sections. The DC section is of the unprecedented DC traction power supply system utilizing IGBT PWM converter at all DC substations. Within the AC section, train traction force is controlled by PWM converter/inverters. The carrier frequencies of the digital data signals and chopping frequency of PWM traction power converters on-board are decided via spectral analysis of noise up to degraded mode cases of equipment. Developed system was equipped to the Tukuba Express Line, new commuter line of Tokyo metropolitan area, and opened since Aug. 2005.

  9. Modelling and Controller Design of Electro-Pneumatic Actuator Based on PWM

    Directory of Open Access Journals (Sweden)

    Behrouz Najjari

    2012-07-01

    Full Text Available In this paper, a nonlinear model associated to the fast switching on-off solenoid valve and pneumatic cylinder was dynamically presented. Furthermore, an investigation into the electrical, magnetic, mechanical and fluid subsystems are made. Two common control policies to track valve position, a Proportional Integrator (PI based on Pulse Width Modulation (PWM and hysteresis controllers, are investigated. To control cylinder position, a Programmable Logic Controller (PLC on a simulated unit and an experimental setup regulated with AVR microcontroller are carried out. Experimental results show effective validation to the simulation results from PLC.

  10. "Class-Bucks": A Motivational Tool to Encourage Active Student Participation during Lectures

    Science.gov (United States)

    de Jager, T.

    2013-01-01

    The purpose of this study was to ascertain the influence of an extrinsic motivational tool, "class-bucks," on the possibility of improving first year student-teachers' participation in active learning at Tshwane University of Technology in South Africa. Research participants (n=289) were divided into four classes and engaged in this…

  11. Control systems for power electronics a practical guide

    CERN Document Server

    Patil, Mahesh

    2015-01-01

    The scope of the book covers most of the aspects as a primer on power electronics starting from a simple diode bridge to a DC-DC convertor using PWM control. The thyristor-bridge and the mechanism of designing a closed loop system are discussed in chapter one, two and three. The concepts are applied in the fourth chapter as a case study for buck converter which uses MOSFETs as switching devices and the closed loop system is elaborated in the fifth chapter. Chapter six is focused on the embedded system basics and the implementation of controls in the digital domain. Chapter seven is a case study of application of an embedded control system for a DC motor. With this book, the reader will find it easy to work on the practical control systems with microcontroller implementation. The core intent of this book is to help gain an accelerated learning path to practical control system engineering and transform control theory to an implementable control system through electronics. Illustrations are provided for most of...

  12. Tratamiento de las hipoplasias severas del pulgar mediante modificaciones a la técnica de Buck-Gramcko

    OpenAIRE

    Peña Marrero, Liván

    2008-01-01

    En este trabajo se evalúa la efectividad de una modificación diseñada por el autor a la técnica de pulgarización del dedo índice descrita por Dieter Buck-Gramcko para el tratamiento de las hipoplasias y aplasias del pulgar. Se realizó un estudio prospectivo longitudinal en 17 pacientes distribuidos en dos grupos. El grupo A estuvo constituido por 9 pacientes (10 manos operadas) a quienes se le aplicó como tratamiento la técnica original de Buck-Gramcko. El grupo B estuvo integrado por 8 pacie...

  13. Elimination of DC-Link Current Ripple for Modular Multilevel Converters With Capacitor Voltage-Balancing Pulse-Shifted Carrier PWM

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2015-01-01

    The modular multilevel converter (MMC) is attractive for medium- and high-power applications because of its high modularity, availability, and power quality. In this paper, the current ripple on the dc link of the three-phase MMC derived from the phase-shifted carrier-based pulse-width modulation...

  14. A 1 MEGAWATT POLYPHASE BOOST CONVERTER-MODULATOR FOR KLYSTRON PULSE APPLICATION

    International Nuclear Information System (INIS)

    Reass, W.A.; Doss, J.D.; Gribble, R.F.

    2001-01-01

    This paper describes electrical design criteria and first operational results a 140 kV, 1 MW average, 11 MW peak, zero-voltage-switching 20 kHz polyphase bridge, boost converter/modulator for klystron pulse application. The DC-DC converter derives the buss voltages from a standard 13.8 kV to 2300 Y substation cast-core transformer. Energy storage and filtering is provided by self-clearing metallized hazy polypropylene traction capacitors. Three ''H-Bridge'' Insulated Gate Bipolar Transistor (IGBT) switching networks are used to generate the polyphase 20 kHz transformer primary drive waveforms. The 20 kHz drive waveforms are chirped the appropriate duration to generate the desired klystron pulse width. PWM (pulse width modulation) of the individual 20 kHz pulses is utilized to provide regulated output waveforms with adaptive feedforward and feedback techniques. The boost transformer design utilizes amorphous nanocrystalline material that provides the required low core loss at design flux levels and switching frequencies. Resonant shunt-peaking is used on the transformer secondary to boost output voltage and resonate transformer leakage inductance. With the appropriate transformer leakage inductance and peaking capacitance, zero-voltage-switching of the IGBT's is attained, minimizing switching losses. A review of these design parameters and the first results of the performance characteristics will be presented

  15. Fish population and habitat analysis in Buck Creek, Washington, prior to recolonization by anadromous salmonids after the removal of Condit Dam

    Science.gov (United States)

    Allen, M. Brady; Burkhardt, Jeanette; Munz, Carrie; Connolly, Patrick J.

    2012-01-01

    We assessed the physical and biotic conditions in the part of Buck Creek, Washington, potentially accessible to anadromous fishes. This creek is a major tributary to the White Salmon River upstream of Condit Dam, which was breached in October 2011. Habitat and fish populations were characterized in four stream reaches. Reach breaks were based on stream gradient, water withdrawals, and fish barriers. Buck Creek generally was confined, with a single straight channel and low sinuosity. Boulders and cobble were the dominant stream substrate, with limited gravel available for spawning. Large-cobble riffles were 83 percent of the available fish habitat. Pools, comprising 15 percent of the surface area, mostly were formed by bedrock with little instream cover and low complexity. Instream wood averaged 6—10 pieces per 100 meters, 80 percent of which was less than 50 centimeters in diameter. Water temperature in Buck Creek rarely exceeded 16 degrees Celsius and did so for only 1 day at river kilometer (rkm) 3 and 11 days at rkm 0.2 in late July and early August 2009. The maximum temperature recorded was 17.2 degrees Celsius at rkm 0.2 on August 2, 2009. Minimum summer discharge in Buck Creek was 3.3 cubic feet per second downstream of an irrigation diversion (rkm 3.1) and 7.7 cubic feet per second at its confluence with the White Salmon River. Rainbow trout (Oncorhynchus mykiss) was the dominant fish species in all reaches. The abundance of age-1 or older rainbow trout was similar between reaches. However, in 2009 and 2010, the greatest abundance of age-0 rainbow trout (8 fish per meter) was in the most downstream reach. These analyses in Buck Creek are important for understanding the factors that may limit fish abundance and productivity, and they will help identify and prioritize potential restoration actions. The data collected constitute baseline information of pre-dam removal conditions that will allow assessment of changes in fish populations now that Condit Dam has

  16. Model Predictive Control of Power Converters for Robust and Fast Operation of AC Microgrids

    DEFF Research Database (Denmark)

    Dragicevic, Tomislav

    2018-01-01

    the load power at the same time. Those functionalities are conventionally achieved by hierarchical linear control loops. However, they have limited transient response and high sensitivity to parameter variations. This paper aims to mitigate these problems by firstly introducing an improvement of the FCS......This paper proposes the application of a finite control set model predictive control (FCS-MPC) strategy in standalone ac microgrids (MGs). AC MGs are usually built from two or more voltage source converters (VSCs) which can regulate the voltage at the point of common coupling, while sharing......-MPC strategy for a single VSC based on tracking of derivative of the voltage reference trajectory. Using only a single step prediction horizon, the proposed strategy exhibits low computational expense but provides steady state performance comparable to PWM, while its transient response and robustness...

  17. The COP9 signalosome converts temporal hormone signaling to spatial restriction on neural competence.

    Directory of Open Access Journals (Sweden)

    Yi-Chun Huang

    2014-11-01

    Full Text Available During development, neural competence is conferred and maintained by integrating spatial and temporal regulations. The Drosophila sensory bristles that detect mechanical and chemical stimulations are arranged in stereotypical positions. The anterior wing margin (AWM is arrayed with neuron-innervated sensory bristles, while posterior wing margin (PWM bristles are non-innervated. We found that the COP9 signalosome (CSN suppresses the neural competence of non-innervated bristles at the PWM. In CSN mutants, PWM bristles are transformed into neuron-innervated, which is attributed to sustained expression of the neural-determining factor Senseless (Sens. The CSN suppresses Sens through repression of the ecdysone signaling target gene broad (br that encodes the BR-Z1 transcription factor to activate sens expression. Strikingly, CSN suppression of BR-Z1 is initiated at the prepupa-to-pupa transition, leading to Sens downregulation, and termination of the neural competence of PWM bristles. The role of ecdysone signaling to repress br after the prepupa-to-pupa transition is distinct from its conventional role in activation, and requires CSN deneddylating activity and multiple cullins, the major substrates of deneddylation. Several CSN subunits physically associate with ecdysone receptors to represses br at the transcriptional level. We propose a model in which nuclear hormone receptors cooperate with the deneddylation machinery to temporally shutdown downstream target gene expression, conferring a spatial restriction on neural competence at the PWM.

  18. Fertility potential of rabbit bucks fed maize-based diets containing graded levels of fumonisin B1

    Directory of Open Access Journals (Sweden)

    Kingsley Idahor

    2012-07-01

    Full Text Available Fumonisin B1-contaminated maize-based diets have been reported to be mycotoxic in animal species, yet more validated data and biomarkers are needed. In this study, Fumonisin B1 (FB1 infected yellow-maize was used to formulate Diets 1, 2 and 3, containing 1,700, 1,800 and 1,900µg FB1/kg diet, respectively. Sixty sexually matured bucks and does were used, but only the bucks were fed the FB1-contaminated diets for eight weeks. At the end of the feeding trial, the treated bucks were mated to the dry does that were fed FB1-free yellow maize-based diet. Effects on testis and live weight, feed utilisation, conception rate, embryo development and spermatozoa production per gram testis were monitored. Results indicated significant depression (P<0.05 in feed intake, from 546.77±12.09g/week in Diet 1 with the lowest FB1 concentration, to 509.84±21.98g/week in Diet 3 with the highest FB1 concentration in the diets. Weight gain was drastically reduced (P<0.05 from 34.13±9.32g/week in Diet 1 to 20.38±22.13g/week in Diet 3. Meanwhile, some of the untreated does were pregnant in all the treatments, indicating that FB1 concentration at 2.0mg/kg diet may not be spermaticidal and there were no abnormalities in the embryos. It was observed that the paired testis weight value in Diet 1 (3.06±0.31 was not significantly different (P>0.05 from that of Diet 3 (2.94±0.23. The testicular elements were distorted by the dietary FB1, but did not follow a definite pattern. Spermatozoa production per gram testis values (31.1 – 37.3 x 106 recorded were much higher than 24 x 106 for a healthy rabbit buck. Consequently, FB1 concentration < 2.0mg/kg diet may not affect the fertility potentials of bucks orally dosed for a relatively short period. This observation further elucidates earlier discoveries that FB1 is not a reproductive toxicant. Hence, the United States Food and Drug Administration proposed a guideline of 2.0mg total fumonisins/kg diet, to be adopted with

  19. A new PWM algorithm for battery-source three-phase inverters

    Energy Technology Data Exchange (ETDEWEB)

    Chan, C.C. (Dept. of Electrical and Electronic Engineering, Univ. of Hong Kong, Pokfulam Road (HK)); Chau, K.T. (Dept. of Electrical Engineering, Hong Kong Polytechnic, Hung Hom (HK))

    1991-01-01

    A new PWM algorithm for battery-source three-phase inverters is described in this paper. The concept of the algorithm is to determine the pulsewidths by equating the areas of the segments of the sinusodial reference with the related output pulse areas. The algorithm is particularly suitable to handle a non-constant voltage source with good harmonic suppression. Since the pulsewidths are computable in real time with minimal storage requirement as well as compact hardware and software, it is especially suitable for single-chip microcomputer implementation. Experimental results show that the single-chip microcomputer Intel 8095-based battery-source inverter can control a 3 kW synchronous motor drive satisfactorily over a frequency range of 2 to 100Hz.

  20. Tratamento da espondilólise sintomática com reparo direto pela técnica de Buck modificada Tratamiento de la espondilolisis sintomática con preparo directo por la técnica de Buck modificada Modified Buck's direct repair to simptomatic spondylolysis treatment

    Directory of Open Access Journals (Sweden)

    Bruno Pinto Coelho Fontes

    2009-03-01

    Full Text Available OBJETIVO: justificar a reconstrução da pars interarticularis pela técnica modificada de Buck como método efetivo no tratamento de lombalgia por espondilólise ou espondilolistese tipo 1, refratárias ao tratamento conservador. MÉTODOS: avaliação retrospectiva de oito pacientes com idade entre 11 e 34 anos, operados e acompanhados no período de outubro de 2004 a maio de 2008 com a técnica de Buck utilizando-se parafusos canulados de titânio. Nenhum paciente foi imobilizado no pós-operatório. Os pacientes foram selecionados após serem submetidos a estudos por imagem utilizando radiografias e ressonância magnética. Também foram avaliados no pós-operatório, segundo os critérios de Henderson e quanto à satisfação com o tratamento, assim como o índice de consolidação. RESULTADOS: sete pacientes foram classificados como excelentes, retornando ao nível de prática esportiva e laboral prévia. Dentre eles, um evoluiu com parestesia transitória, com recuperação completa. A oitava paciente apresentou uma pseudartrose bilateral, mas com bom resultado do ponto de vista clínico. Todos os pacientes ficaram satisfeitos com o resultado. CONCLUSÃO: a reconstrução ístmica com parafusos de titânio atingiu excelentes resultados ao aliar biomecânica estável, dissecção mínima da musculatura, com preservação da anatomia e mobilidade do segmento.OBJETIVO: justificar la reconstrucción de la pars interarticularis por la técnica modificada de Buck como método efectivo en el tratamiento de la lumbalgia por espondilosis o espondilolistesis tipo 1, refractarias al tratamiento conservador. MÉTODOS: evaluación retrospectiva de ocho pacientes con edad entre 11 a 34 años, operados y acompañados en el periodo de Octubre de 2004 hasta Mayo de 2008 con la técnica de Buck usando tornillos canulados de titanio. Ningún paciente fue inmovilizado en el postoperatorio. Los pacientes fueron seleccionados después de ser sometidos a

  1. Design of resonant converter based DC power supply for RF amplifier

    International Nuclear Information System (INIS)

    Mohan, Kartik; Suthar, Gajendra; Dalicha, Hrushikesh; Agarwal, Rohit; Trivedi, R.G.; Mukherjee, Aparajita

    2017-01-01

    ITER require 20 MW of RF power to a large variety of plasmas in the Ion Cyclotron frequency range for heating and driving plasma current. Nine RF sources of 2.5MW RF power level each collectively will accomplish the above requirement. Each RF source consists of SSPA, driver and end stage, above which driver and end stage amplifier are tube (Tetrode/Diacrode) based which requires auxiliary DC power source viz. filament, screen grid and control grid DC power supply. DC power supply has some stringent requirements like low stored energy, fast turn off, and low ripple value, etc. This paper will focus only on Zero Current Switching (ZCS) resonant converter based buck converter. This can serve the purpose of control grid and screen grid DC power supply for above requirement. IGBT switch will be used at 20 kHz so as to lower the filter requirement hence low stored energy and ripple in the output voltage. ZCS operation will also assist us in reducing EMI/EMC effect. Design of resonant tank circuit is important aspect of the converter as it forms the backbone of the complete system and basis of selection of other important parameters as well hence mathematical model analysis with the help of circuit equations for various modes have been shown as a part of selection criteria. Peak current through the switch, duty cycle, switching frequency will be the design parameters for selecting resonant tank circuit

  2. Backscatter 0.5m TIFF Mosaic of St. Croix (Buck Island), US Virgin Islands, 2004

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a 0.5 meter resolution backscatter mosaic of the north shore of Buck Island, St. Croix, US Virgin Islands. NOAA's NOS/NCCOS/CCMA Biogeography...

  3. Power system stabilization by SMES using current-fed pwm power conditioner

    International Nuclear Information System (INIS)

    Ishikawa, T.; Akita, S.; Taniguchi, H.; Kosho, S.; Tanaka, T.

    1988-01-01

    A superconducting magnetic energy storage (SMES) unit, consisted of superconducting coil and AC/DC power conditioner, can be used to suppress various kinds of instability that may cause service interruption in electric power system as it has high controllability of input/output electric power. Power system stabilizing ability of SMES has been examined experimentally by using model power system and small SMES unit. Current-fed PWM power conditioner was used to obtain maximum stabilizing effect by controlling active and reactive power simultaneously and independently. Power conditioner configuration, operating characteristics and control scheme for power system stabilization are also described. Results from experiments show the effectiveness of SMES on power system stabilization

  4. Evaluation of custom-designed lateral power transistors in a silicon-on-insulator process in a synchronous buck converter

    DEFF Research Database (Denmark)

    Okumus, Sinan; Fan, Lin; Nour, Yasser

    2018-01-01

    Most of todays power converters are based on power semiconductors, which are built in vertical power semiconductor processes. These devices result in limited packaging possibilities, which lead to physically long galvanic connections and therefore high external electromagnetic fields. These fields...

  5. Practical switching power supply design

    CERN Document Server

    Brown, Martin C

    1990-01-01

    Take the ""black magic"" out of switching power supplies with Practical Switching Power Supply Design! This is a comprehensive ""hands-on"" guide to the theory behind, and design of, PWM and resonant switching supplies. You'll find information on switching supply operation and selecting an appropriate topology for your application. There's extensive coverage of buck, boost, flyback, push-pull, half bridge, and full bridge regulator circuits. Special attention is given to semiconductors used in switching supplies. RFI/EMI reduction, grounding, testing, and safety standards are also deta

  6. Aalborg Inverter - A New Type of “Buck in Buck, Boost in Boost” Grid-Tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Ji, Junhao; Blaabjerg, Frede

    2015-01-01

    This paper presents a new family of high efficiency dc/ac grid-tied inverter with a wide variation of input dc voltage. It is a “boost in boost, buck in buck” inverter, meaning that only one power stage works at high frequency in order to achieve minimum switching loss. The minimum voltage drop...... of the filtering inductor in the power loop is achieved to reduce the conduction power loss in both “boost” and “buck” mode. The principle of operation is demonstrated through the analysis on the equivalent circuits of a “half-bridge” single-phase inverter. The theoretical analysis shows that when input dc voltage...... is larger than the magnitude of the ac voltage, it is a voltage-source inverter, and on the contrary it is current-source inverter in the other mode. A 220 V/50 Hz/ 2000 W prototype has been constructed. Simulations and experiments show that it has a good control and system performance....

  7. A Practical Core Loss Model for Filter Inductors of Power Electronic Converters

    DEFF Research Database (Denmark)

    Matsumori, Hiroaki; Shimizu, Toshihisa; Wang, Xiongfei

    2018-01-01

    This paper proposes a core loss model for filter inductors of power electronic converters. The model allows a computationally efficient analysis on the core loss of the inductor under the square voltage excitation and the premagnetization condition. First, the core loss of the filter inductor under...... buck chopper excitation is evaluated with the proposed model and compared with the conventional methods. The comparison shows that the proposed method results in a better core loss prediction under the premagnetized condition than that of conventional alternatives. Then, the core loss of the filter...... inductor with the pulsewidth modulated inverter excitation is evaluated, which shows that the proposed model not only accurately predicts the core loss but also identifies the hysteresis loss part. These results demonstrate that the approach can further be used for the development of magnetic materials...

  8. Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch

    Directory of Open Access Journals (Sweden)

    Yusuke Hayashi

    2016-01-01

    Full Text Available An active gate controlled semiconductor protection switch using SiC-MOSFET is proposed to achieve the fault tolerant operation of ISOP (Input Series and Output Parallel connected multicell dc-dc converter. The SiC-MOSFET with high temperature capability simplifies the configuration of the protection circuit, and its on-resistance control by the active gate controller realizes the smooth protection without the voltage and the current surges. The first laboratory prototype of the protection switch is fabricated by using a SiC-MOSFET with a high frequency buck chopper for the active gate controller. The effectiveness of the proposed protection switch is verified, taking the impact of the volume reduction into account.

  9. Synchronized Scheme of Continuous Space-Vector PWM with the Real-Time Control Algorithms

    DEFF Research Database (Denmark)

    Oleschuk, V.; Blaabjerg, Frede

    2004-01-01

    This paper describes in details the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of three-phase voltage source inverters for adjustable speed ac drives. It is applied to a continuous scheme of voltage space vector modulation. The method is based...... their position inside clock-intervals. In order to provide smooth shock-less pulse-ratio changing and quarter-wave symmetry of the voltage waveforms, special synchronising signals are formed on the boundaries of the 60 clock-intervals. The process of gradual transition from continuous to discontinuous...

  10. Estimating return levels from maxima of non-stationary random sequences using the Generalized PWM method

    Directory of Open Access Journals (Sweden)

    P. Ribereau

    2008-12-01

    Full Text Available Since the pioneering work of Landwehr et al. (1979, Hosking et al. (1985 and their collaborators, the Probability Weighted Moments (PWM method has been very popular, simple and efficient to estimate the parameters of the Generalized Extreme Value (GEV distribution when modeling the distribution of maxima (e.g., annual maxima of precipitations in the Identically and Independently Distributed (IID context. When the IID assumption is not satisfied, a flexible alternative, the Maximum Likelihood Estimation (MLE approach offers an elegant way to handle non-stationarities by letting the GEV parameters to be time dependent. Despite its qualities, the MLE applied to the GEV distribution does not always provide accurate return level estimates, especially for small sample sizes or heavy tails. These drawbacks are particularly true in some non-stationary situations. To reduce these negative effects, we propose to extend the PWM method to a more general framework that enables us to model temporal covariates and provide accurate GEV-based return levels. Theoretical properties of our estimators are discussed. Small and moderate sample sizes simulations in a non-stationary context are analyzed and two brief applications to annual maxima of CO2 and seasonal maxima of cumulated daily precipitations are presented.

  11. Using a coupled inductor controlled by fuzzy logic to improve the efficiency of a Buck converter in a PV system

    Directory of Open Access Journals (Sweden)

    Abouchabana Nabil

    2017-01-01

    Full Text Available Photovoltaic generators (PVG produce a variable power according to the solar radiation (G and temperature (T. This variation affects the sizing of the components of DC / DC converters, powered by such PVG, and make it difficult. The effects may differ from one component to another. The main and critical one is presented by the inductor, the element that stores the energy during sampled periods. We propose in this work an auto-adaptation of these inductor values to maintain optimal performance of the power yield of these converters. Our idea is to replace the inductor by a coupled inductor where this adjustment is made by the addition of an adjustable electric field in the magnetic core. Low current intensities come from the PVG supply the second inductor of the coupled inductor through a circuit controlled by a fuzzy controller (FC. The whole system is modeled and simulated under MATLAB/SIMULINK for the control part of the system and under PSPICE for the power part of the system. The obtained results show good performances of the proposed converter over the standard one.

  12. Using a coupled inductor controlled by fuzzy logic to improve the efficiency of a Buck converter in a PV system

    Science.gov (United States)

    Abouchabana, Nabil; Haddadi, Mourad; Rabhi, Abdelhamid; El Hajjaji, Ahmed

    2017-11-01

    Photovoltaic generators (PVG) produce a variable power according to the solar radiation (G) and temperature (T). This variation affects the sizing of the components of DC / DC converters, powered by such PVG, and make it difficult. The effects may differ from one component to another. The main and critical one is presented by the inductor, the element that stores the energy during sampled periods. We propose in this work an auto-adaptation of these inductor values to maintain optimal performance of the power yield of these converters. Our idea is to replace the inductor by a coupled inductor where this adjustment is made by the addition of an adjustable electric field in the magnetic core. Low current intensities come from the PVG supply the second inductor of the coupled inductor through a circuit controlled by a fuzzy controller (FC). The whole system is modeled and simulated under MATLAB/SIMULINK for the control part of the system and under PSPICE for the power part of the system. The obtained results show good performances of the proposed converter over the standard one.

  13. A Low Input Current and Wide Conversion Ratio Buck Regulator with 75% Efficiency for High-Voltage Triboelectric Nanogenerators

    Science.gov (United States)

    Luo, Li-Chuan; Bao, De-Chun; Yu, Wu-Qi; Zhang, Zhao-Hua; Ren, Tian-Ling

    2016-01-01

    It is meaningful to research the Triboelectric Nanogenerators (TENG), which can create electricity anywhere and anytime. There are many researches on the structures and materials of TENG to explain the phenomenon that the maximum voltage is stable and the current is increasing. The output voltage of the TENG is high about 180-400 V, and the output current is small about 39 μA, which the electronic devices directly integration of TENG with Li-ion batteries will result in huge energy loss due to the ultrahigh TENG impedance. A novel interface circuit with the high-voltage buck regulator for TENG is introduced firstly in this paper. The interface circuit can transfer the output signal of the TENG into the signal fit to a lithium ion battery. Through the circuit of the buck regulator, the average output voltage is about 4.0 V and the average output current is about 1.12 mA. Further, the reliability and availability for the lithium ion battery and the circuit are discussed. The interface circuit is simulated using the Cadence software and verified through PCB experiment. The buck regulator can achieve 75% efficiency for the High-Voltage TENG. This will lead to a research hot and industrialization applications.

  14. On Some Extensions of Szasz Operators Including Boas-Buck-Type Polynomials

    Directory of Open Access Journals (Sweden)

    Sezgin Sucu

    2012-01-01

    Full Text Available This paper is concerned with a new sequence of linear positive operators which generalize Szasz operators including Boas-Buck-type polynomials. We establish a convergence theorem for these operators and give the quantitative estimation of the approximation process by using a classical approach and the second modulus of continuity. Some explicit examples of our operators involving Laguerre polynomials, Charlier polynomials, and Gould-Hopper polynomials are given. Moreover, a Voronovskaya-type result is obtained for the operators containing Gould-Hopper polynomials.

  15. Battery pack state of charge balancing algorithm for cascaded H-Bridge multilevel converters

    DEFF Research Database (Denmark)

    Máthé, Lászlo; Burlacu, Paul Dan; Schaltz, Erik

    2016-01-01

    For most of the Multilevel Converter (MC) applications a commonly discussed issue is the maintenance of balance between the energy storage elements from the SubModules (SM). In applications where a battery pack is also part of the SM storage, such as STATCOMs or motor drives, the SM voltage...... is not in linear relation with the State Of Charge (SOC) of the entire battery; thus, the balancing becomes more cumbersome. A method to balance the SOC of the battery packs in a system using cascaded H-Bridge is proposed in this paper. The method uses nearest level control followed by sorting and selection based...... on the SOC of the battery packs. Based on the simulation results the number of switching is reduced considerably compared to the method where the phase shifted PWM is used. In addition, the time needed to achieve the balanced SOC is also reduced. The proposed method has been verified through experiments...

  16. Thin grain oriented electrical steel for PWM voltages fed magnetic cores

    Directory of Open Access Journals (Sweden)

    Thierry Belgrand

    2018-04-01

    Full Text Available This paper reports on performances of high permeability grain oriented electrical steel when used in association with power electronic switching devices. Loss measurement results obtained from the Epstein test, using sinusoidal or various PWM voltages in medium frequency range, show that for both studied thicknesses (HGO 0.23mm and HGO 0.18mm, comparing performances at a fixed induction level between the various situations may not be the most convenient method. The effect of magnetic domain refinement has been investigated. After having shown the interest of lowering the thickness, an alternative way of looking at losses is proposed that may help to design the magnetic core when it comes to the matter of reducing size in considering frequency and magnetization levels.

  17. Toward a reduced-wire readout system for ultrasound imaging.

    Science.gov (United States)

    Lim, Jaemyung; Arkan, Evren F; Degertekin, F Levent; Ghovanloo, Maysam

    2014-01-01

    We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply.

  18. Bathymetry 1M Grid of St. Croix (Buck Island), US Virgin Islands 2005, UTM 20 NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains an ESRI Grid with 1 meter cell size representing the bathymetry of the north shore of St. Croix (Buck Island), US Virgin Islands. NOAA's...

  19. NOAA TIFF Graphic- 0.5m Backscatter Mosaic of St. Croix (Buck Island), US Virgin Islands, 2004

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This geotiff represents a 0.5 meter resolution backscatter mosaic of the north shore of Buck Island, St. Croix, US Virgin Islands.NOAA's NOS/NCCOS/CCMA Biogeography...

  20. Bathymetry 1M GRID of St. Croix (Buck Island), US Virgin Islands, 2004, UTM 20 WGS84

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains an ESRI Grid with 1 meter cell size representing the bathymetry of the north shore of Buck Island St. Croix, US Virgin Islands. NOAA's...

  1. NOAA TIFF Graphic- 0.5m Backscatter Mosaic of St. Croix (Buck Island), US Virgin Islands, 2004

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a 1 meter resolution backscatter mosaic of the north shore of Buck Island, St. Croix, US Virgin Islands.NOAA's NOS/NCCOS/CCMA Biogeography Team...

  2. Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.

    2004-03-15

    In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed towards amplification of the audio signal. In order to solve the problem with the commutation of the load current, a dead time between the incoming and outgoing bidirectional switch is implemented, while a capacitive voltage clamp is used to keep the induced overvoltage to reasonable levels. The energy stored in the clamping capacitor is not wasted as in the dissipative clamps, but is rather transferred back to the primary side for further processing using an auxiliary isolated single-switch converter, i.e. an active clamping technique is used. (au)

  3. Radiometric sampling of bucked copper-nickel ores for determining chemical composition

    International Nuclear Information System (INIS)

    Komlev, V.N.; Eliseev, G.I.

    1978-01-01

    Presented are the results and the technique of experimental-methodical works on radiometric sampling of bucked copper-nickel ores for determining chemical composition with their selection and analysis by the neutron-gamma method and by the gamma-gamma method. The error is estimated according to the chosen conditions of sampling. It is found that the gamma-gamma method being more rapid but less accurate is applied for rapid control of ore current, whereas the neutron-gamma method is applied for quality control of ores extracted

  4. A Comparison of Phase-Shift Self- Oscillating and Carrier-based PWM Modulation for Embedded Audio Amplifiers

    OpenAIRE

    Huffenus , Alexandre; Pillonnet , Gaël; Abouchi , Nacer; Goutti , Frédéric

    2010-01-01

    International audience; This paper compares two modulation schemes for Class-D amplifiers: Phase-Shift Self-Oscillating (PSSO) and Carrier-Based Pulse Width Modulation (PWM). Theoretical analysis (modulation, frequency of oscillation, bandwidth…), design procedure, and IC silicon evaluation will be shown for mono and stereo operation (on the same silicon die) on both structures. The design of both architectures will use as many identical building blocks as possible, to provide a fair, "all el...

  5. Toxic effects of arsenic on semen and hormonal profile and their amelioration with vitamin E in Teddy goat bucks.

    Science.gov (United States)

    Zubair, M; Ahmad, M; Jamil, H; Deeba, F

    2016-12-01

    The present environmental study has been planned to investigate the toxic effects of arsenic on reproductive functions of Teddy bucks as well as to examine whether these toxic effects are ameliorated by vitamin E. Sixteen adult Teddy bucks were divided randomly into four equal groups A, B, C and D with following treatment: A (control), B (sodium arsenite 5 mg kg -1 BW day -1 ), C (vit E 200 mg kg -1 BW day -1  + Arsenic 5 mg kg -1 BW day -1 ) and D (vit E 200 mg kg -1 BW day -1 ). This treatment was continued for 84 days. Semen quality parameters were evaluated weekly. Male testosterone, luteinising hormone (LH), follicle-stimulating hormone (FSH) and cortisol levels were measured through enzyme-linked immunosorbent assay (ELISA) after every 2 weeks. The data were subjected to two-way analysis of variance followed by Duncan test for multiple comparisons. Semen evaluation parameters were reduced significantly (P semen and hormonal parameters. It may be concluded from this study that sodium arsenite causes major toxicity changes in semen and hormonal profile in Teddy goat bucks and vitamin E has ameliorative effects on these toxic changes. © 2016 Blackwell Verlag GmbH.

  6. Efficient Visible Light Communication Transmitters Based on Switching-Mode dc-dc Converters

    Science.gov (United States)

    2018-01-01

    Visible light communication (VLC) based on solid-state lighting (SSL) is a promising option either to supplement or to substitute existing radio frequency (RF) wireless communication in indoor environments. VLC systems take advantage of the fast modulation of the visible light that light emitting diodes (LEDs) enable. The switching-mode dc-to-dc converter (SMCdc-dc) must be the cornerstone of the LED driver of VLC transmitters in order to incorporate the communication functionality into LED lighting, keeping high power efficiency. However, the new requirements related to the communication, especially the high bandwidth that the LED driver must achieve, converts the design of the SMCdc-dc into a very challenging task. In this work, three different methods for achieving such a high bandwidth with an SMCdc-dc are presented: increasing the order of the SMCdc-dc output filter, increasing the number of voltage inputs, and increasing the number of phases. These three strategies are combinable and the optimum design depends on the particular VLC application, which determines the requirements of the VLC transmitter. As an example, an experimental VLC transmitter based on a two-phase buck converter with a fourth-order output filter will demonstrate that a bandwidth of several hundred kilohertz (kHz) can be achieved with output power levels close to 10 W and power efficiencies between 85% and 90%. In conclusion, the design strategy presented allows us to incorporate VLC into SSL, achieving high bit rates without damaging the power efficiency of LED lighting. PMID:29642455

  7. Modeling, Development and Control of Multilevel Converters for Power System Application =

    Science.gov (United States)

    Vahedi, Hani

    successfully to work in both stand-alone and gridconnected mode of operation. Eventually, a modified configuration of the PUC5 topology is presented to work as a buck PFC rectifier. The internal performance of the rectifier is like a buck converter to generate stepped down DC voltages at the two output terminals while the grid sees a boost converter externally. As well, a decoupled voltage/current controller is designed and applied to balance the output voltages identically and synchronize the input current with grid voltage to have a PFC operation acceptably. A power balance analysis is done to show the load variation range limit. All the theoretical and simulation studies are validated by experimental results completely.

  8. Multi-Output Power Converter, Operated from a Regulated Input Bus, for the Sireus Rate Sensor

    Directory of Open Access Journals (Sweden)

    Torrecilla Marcos Compadre

    2017-01-01

    Full Text Available This paper describes a DC to DC converter designed to meet the power supply requirements of the SiREUS Coarse Rate Sensor (CRS which is a 3-axis MEMS Rate Sensor (MRS that uses a resonating ring gyro and will be used in different ESA missions. The converter supplies +5V, −5V, 3.3V, 1.8V and 40V and it has been designed and prototyped by Clyde Space Ltd with the EQM and FM units being manufactured by Selex ES. The first model was designed for a 28V un-regulated bus and the second model presented here has been designed for a 50V regulated bus. PWM voltage regulation was not used because of the noise requirements and the regulated input bus allowed an unregulated power stage approach. There are also stringent volume and interface constraints, which also affected the design. For such reasons, a fixed dutycycle, quasi-resonant single-ended topology with output linear regulators has been implemented; having the advantages of providing low switching losses, low radiated and conducted noise and no over-voltage failure mode. This paper highlights the techniques used to satisfy stringent noise and protection requirements of the load.

  9. Nutrient utilisation and blood chemistry of Red Sokoto bucks fed on diets with different inclusion levels of raw and soaked roselle (Hibiscus sabdariffa L. seeds

    Directory of Open Access Journals (Sweden)

    Taofik Adam Ibrahim

    2018-04-01

    Full Text Available This study evaluated nutrient utilisation and blood chemistry of Red Sokoto bucks fed a 10 and 20 % inclusion level of raw, water- and lime-soaked Hibiscus sabdariffa L. seeds in rice bran based diets. 21 Red Sokoto bucks aged 8–10 months and weighing 9–13 kg were randomly allotted into six treatments with three bucks each, while a seventh dietary treatment with zero inclusion of seeds served as control in a 2 × 3 factorial arrangement using a complete randomised design. The results indicated that increase in dietary inclusion levels of soaked H. sabdariffa seeds increased (P < 0.05 the nutrient utilisation of bucks as compared to the control, while a decrease was observed with increasing dietary inclusion levels of raw seeds. Dietary inclusion of both raw and water-soaked H. sabdariffa seeds increased (P < 0.05 the packed cell volume. Soaking also influenced the white blood cell value which increased with increasing inclusion levels of H. sabdariffa seeds. However, values of haemoglobin and red blood cells were only affected by 20 % inclusion of raw and water-soaked H. sabdariffa seeds (P < 0.05 compared to control. Inclusion of H. sabdariffa seeds furthermore reduced serum protein, albumin, globulin, glucose and urea levels compared to control. It is therefore concluded that H. sabdariffa seeds support haematopoiesis in Red Sokoto bucks. While both inclusion levels of water-soaked and 10 % raw H. sabdariffa seeds improved nutrient utilisation compared to control and 20 % inclusion of raw seeds, the 20 % inclusion of water-soaked H. sabdariffa seeds recorded the best nitrogen utilisation efficiency.

  10. PWM Inverter control and the application thereof within electric vehicles

    Science.gov (United States)

    Geppert, Steven

    1982-01-01

    An inverter (34) which provides power to an A.C. machine (28) is controlled by a circuit (36) employing PWM control strategy whereby A.C. power is supplied to the machine at a preselectable frequency and preselectable voltage. This is accomplished by the technique of waveform notching in which the shapes of the notches are varied to determine the average energy content of the overall waveform. Through this arrangement, the operational efficiency of the A.C. machine is optimized. The control circuit includes a micro-computer and memory element which receive various parametric inputs and calculate optimized machine control data signals therefrom. The control data is asynchronously loaded into the inverter through an intermediate buffer (38). In its preferred embodiment, the present invention is incorporated within an electric vehicle (10) employing a 144 VDC battery pack (32) and a three-phase induction motor (18).

  11. Design Research on Three-Phase PWM Rectifier Based on Double Closed Loop Control Technology

    Directory of Open Access Journals (Sweden)

    Guang Ya LIU

    2014-02-01

    Full Text Available Based on the high frequency of three-phase voltage source PWM rectifier, this paper established a mathematical model of three phase current inner ring and outer ring voltage, and put forward the setting method of three phase double closed loop control. Finally, it was verified through simulation. The experimental results show that Three-phase output of DC voltage is stable with the operation of regulating systems, the current flowing into the grid tends to be sinusoidal and power factor is close to 1, which greatly reduce the interference of harmonics on the grid, thus improve grid operation.

  12. Grid-friendly wind power systems based on the synchronverter technology

    International Nuclear Information System (INIS)

    Zhong, Qing-Chang; Ma, Zhenyu; Ming, Wen-Long; Konstantopoulos, George C.

    2015-01-01

    Highlights: • A grid-friendly wind power system that uses the synchronverter technology is proposed. • Both the rotor-side and the grid-side converters act as synchronverters. • The complete generator–motor–generator system improves the performance under grid faults. • Real-time digital simulation results verify the effectiveness of the proposed method. - Abstract: Back-to-back PWM converters are becoming a realistic alternative to conventional converters in high-power wind power applications. In this paper, a control strategy based on the synchronverter technology is proposed for back-to-back PWM converters. Both converters are run as synchronverters, which are mathematically equivalent to the conventional synchronous generators. The rotor-side converter is responsible for maintaining the DC link voltage and the grid-side converter is responsible for the maximum power point tracking (MPPT). As the two converters are operated using the synchronverter technology, the formed wind power system becomes more friendly to the grid. Extensive real-time digital simulation results are presented to verify the effectiveness of the proposed method under normal operation and grid-fault scenarios

  13. Correlation of biochemical constituents of seminal plasma with semen quality in Teddy goat (Capra hircus) bucks.

    Science.gov (United States)

    Umar, S; Ahmad, M; Ahmad, I; Zubair, M; Umar, Z; Qureshi, A S; Manzoor, A; Murtaza, A; Shaukat, A

    2018-04-01

    This study was planned to determine the relationship between semen quality parameters and the levels of biochemical constituents of seminal plasma of Teddy (Capra hircus) buck semen. For this purpose, semen ejaculates were collected from five mature healthy Teddy bucks. All the experimental bucks were kept under natural environmental conditions. Semen was collected twice in a week for the duration of 6 weeks by Artificial Vagina (AV) in the breeding season (February-April). Two successive ejaculates of single buck were pooled at time of collection, and a total of 60 semen samples were processed for semen analysis. Sperm per cent motility, sperm concentration, dead sperm percentage, morphological abnormal spermatozoa, plasma membrane integrity were correlated with biochemical constituents of seminal plasma. The mean per cent motility (89.18% ± 0.37%), sperm concentration (1.86 ± 0.04 × 10 9 /ml), dead sperm percentage (8.08% ± 0.29%), morphological abnormal spermatozoa (6.05% ± 0.29%) and plasma membrane integrity (88.22% ± 0.34%) were recorded. The seminal plasma contained Na + (144.12 ± 1.59 mEq/L), K + (27.38 ± 0.49 mEq/L), Cl - (65.73 ± 0.45 mEq/L), Ca ++ (9.34 ± 0.22 mg/dl), P (19.32 ± 0.97 mg/dl), aspartate aminotransferase (AST; 26.48 ± 1.30 IU/L), alanine aminotransferase (ALT; 168.47 ± 5.18 IU/L), lactate dehydrogenase (LDH; 215.98 ± 6.06 IU/L), albumin (1.90 ± 0.10 g/dl), globulins (2.08 ± 0.11 g/dl) and total protein (3.98 ± 0.20 g/dl). The collected data were analysed by applying Pearson's correlation coefficients. Dead sperm percentage had negative correlation with sodium (r = -.278, p correlated with plasma membrane integrity (r = -.292, p correlated with biochemical constituents, but opposite trends were found in case of dead sperm percentage. The seminal biochemical constituents dynamically interact with each other. © 2017 Blackwell Verlag GmbH.

  14. multilevel buck converter for automotive electrical load

    African Journals Online (AJOL)

    user

    The electrical low voltage load requirement in the passenger vehicle is ... oxides emissions, and 82% of carbon monoxides (CO). [4]. ... government placed an order restricting the movement ... transient and steady-state characteristics of the.

  15. Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

    Science.gov (United States)

    Bell, J. Brett; Nelms, R. M.; Shepherd, Michael T.

    1993-01-01

    The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

  16. Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

    Science.gov (United States)

    Bell, J. Brett; Nelms, R. M.; Shepherd, Michael T.

    The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

  17. GeoTIFF of 3x3 m Bathymetry for Buck Island, St. Croix, 2011, UTM 20N NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a LiDAR (Light Detection & Ranging) 3x3 meter resolution bathymetric surface for an area including and surrounding Buck Island Reef...

  18. Design and Simulation to Composite PI Controller on the Stratospheric Airship

    Directory of Open Access Journals (Sweden)

    Kangwen Sun

    2014-05-01

    Full Text Available In view of the stratospheric airship application requirements on energy storage and management system, based on the topology of DC/DC converter main circuit, the composite PI controller is designed to realize respective control with the Boost mode and Buck mode. Furthermore, limit stop integration method is proposed to achieve a buck-boost complex DC/DC converter boost with effective switching buck. Then, with the MATLAB Control System Toolbox design model, the composite PI controller design and a simulation is accomplished. According to the simulation model, the structure and parameters of the controller to the system can be easily adjusted. Finally, by using the average large-signal switching mathematical model to create sub-circuit in place of the actual circuit model, the whole circuit model of the DC/DC converter is constructed with MATLAB, and then, from the analysis of simulation results, it’s proved that the method can shorten the simulation time and obtain better convergence of the target.

  19. Distributed maximum power point tracking in photovoltaic applications: active bypass DC/DC converter

    Directory of Open Access Journals (Sweden)

    Carlos Andrés Ramos-Paja

    2012-01-01

    Full Text Available Se propone una estructura de desvío activo para maximizar la producción de potencia en sistemas fotovoltaicos bajo condiciones irregulares de operación, comparando su eficiencia con soluciones individuales y distribuidas basadas en convertidores DC/DC convencionales. Los análisis y simulaciones realistas demuestran las ventajas del nuevo convertidor de desvío activo sobre soluciones basadas en convertidores Boost, Buck y Buck-Boost.

  20. Modeling of Maximum Power Point Tracking Controller for Solar Power System

    Directory of Open Access Journals (Sweden)

    Aryuanto Soetedjo

    2012-09-01

    Full Text Available In this paper, a Maximum Power Point Tracking (MPPT controller for solar power system is modeled using MATLAB Simulink. The model consists of PV module, buck converter, and MPPT controller. The contribution of the work is in the modeling of buck converter that allowing the input voltage of the converter, i.e. output voltage of PV is changed by varying the duty cycle, so that the maximum power point could be tracked when the environmental changes. The simulation results show that the developed model performs well in tracking the maximum power point (MPP of the PV module using Perturb and Observe (P&O Algorithm.

  1. NOAA ESRI Geotiff- 1m Bathymetry of St. Croix (Buck Island), US Virgin Islands, 2004, UTM 20 WGS84

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains an ESRI Geotiff with 1 meter cell size representing the bathymetry of the north shore of Buck Island St. Croix, US Virgin Islands.NOAA's...

  2. Evaluation of biofidelity of THUMS pedestrian model under a whole-body impact conditions with a generic sedan buck.

    Science.gov (United States)

    Wu, Taotao; Kim, Taewung; Bollapragada, Varun; Poulard, David; Chen, Huipeng; Panzer, Matthew B; Forman, Jason L; Crandall, Jeff R; Pipkorn, Bengt

    2017-05-29

    The goal of this study was to evaluate the biofidelity of the Total Human Model for Safety (THUMS; Ver. 4.01) pedestrian finite element models (PFEM) in a whole-body pedestrian impact condition using a well-characterized generic pedestrian buck model. The biofidelity of THUMS PFEM was evaluated with respect to data from 3 full-scale postmortem human subject (PMHS) pedestrian impact tests, in which a pedestrian buck laterally struck the subjects using a pedestrian buck at 40 km/h. The pedestrian model was scaled to match the anthropometry of the target subjects and then positioned to match the pre-impact postures of the target subjects based on the 3-dimensional motion tracking data obtained during the experiments. An objective rating method was employed to quantitatively evaluate the correlation between the responses of the models and the PMHS. Injuries in the models were predicted both probabilistically and deterministically using empirical injury risk functions and strain measures, respectively, and compared with those of the target PMHS. In general, the model exhibited biofidelic kinematic responses (in the Y-Z plane) regarding trajectories (International Organization for Standardization [ISO] ratings: Y = 0.90 ± 0.11, Z = 0.89 ± 0.09), linear resultant velocities (ISO ratings: 0.83 ± 0.07), accelerations (ISO ratings: Y = 0.58 ± 0.11, Z = 0.52 ± 0.12), and angular velocities (ISO ratings: X = 0.48 ± 0.13) but exhibited stiffer leg responses and delayed head responses compared to those of the PMHS. This indicates potential biofidelity issues with the PFEM for regions below the knee and in the neck. The model also demonstrated comparable reaction forces at the buck front-end regions to those from the PMHS tests. The PFEM generally predicted the injuries that the PMHS sustained but overestimated injuries in the ankle and leg regions. Based on the data considered, the THUMS PFEM was considered to be biofidelic for this pedestrian impact condition and vehicle

  3. Versions and perversions of rigid frames: The bucking importance in the beams design of industrial warehouses

    International Nuclear Information System (INIS)

    Guerra Romero, I.; Fernandez Majo, M. C.; Valdes, A. J.

    2010-01-01

    In this paper many bibliographic references have been analyses which deal on the importance of the buckling in rigid frames, and many versions of it, have been got. About 70 frames have been analysed by the authors and they have found that it is advisable to consider the bucking in the design of frames beams. (Author) 30 refs.

  4. Effect of Priangan ram seminal plasma on viability of Peranakan Etawah buck spermatozoa preserved at 3–5oC

    Directory of Open Access Journals (Sweden)

    Muhammad Rizal

    2008-03-01

    Full Text Available In processing of buck semen, seminal plasma is a problem because it contains a phospholipase A enzime produced by the Cowper gland. If this enzime interacts with egg yolk, it causes semen coagulation, and consequently death of spermatozoa. The purpose of this research was to examine the effect of Priangan ram seminal plasma on viability of Peranakan Etawah (PE buck spermatozoa preserved at 3–5oC. Semen was collected using artificial vagina once a week. Fresh semen was divided into three tubes then centrifuged at 3,000 RPM for 30 min. Supernatant of the first tube was mixed again with Pasteur pipette (treatment A or control. Supernatant of the second tube was removed (treatment B or without seminal plasma. Supernatant of the third tube was removed and changed with Priangan ram seminal plasma in the same volume (treatment C. Semen was diluted with Tris extender containing 20% egg yolk and stored in refrigerator at 3–5oC. Quality of diluted-semen including percentages of motile spermatozoa (MS, live spermatozoa (LS, and intact plasma membrane (IPM was evaluated every day during storage at 3–5oC for three days. Results of this study showed that mean volume, colour, consistency, pH, mass activity, spermatozoa concentration, MS, LS, spermatozoa abnormal, and IPM of PE buck fresh semen, respectively was 0.68 ml, cream, thick, 7, ++/+++, 4,148.57 million cell/ml, 70%, 83.89%, 7.12% and 84%. At day-4 of storage, percentages of MS, LS, and IPM for treatment C (40, 52.2 and 51.6% was significantly (P<0.05 higher than that of: treatment B (31, 44.8 and 45.2% and treatment A (11, 15.6 and 14.8%. In conclusion, seminal plasma of Priangan ram could maintain the quality of PE buck semen preserved at 3–5oC for three days, and it prevent semen from coagulation.

  5. GeoTIFF of 3x3 m Relative Reflectivity for Buck Island, St. Croix, 2011, UTM 20N NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a LiDAR (Light Detection & Ranging) 3x3 meter resolution relative seafloor reflectivity surface for an area including and surrounding Buck...

  6. One-Stage and Two-Stage Schemes of High Performance Synchronous PWM with Smooth Pulses-Ratio Changing

    DEFF Research Database (Denmark)

    Oleschuk, V.; Blaabjerg, Frede

    2002-01-01

    This paper presents detailed description of one-stage and two-stage schemes of a novel method of synchronous, pulsewidth modulation (PWM) for voltage source inverters for ac drive application. The proposed control functions provide accurate realization of different versions of voltage space vector...... modulation with synchronization of the voltage waveform of the inverter and with smooth pulse-ratio changing. Voltage spectra do not contain even harmonic and sub-harmonics (combined harmonics) during the whole control range including the zone of overmodulation. Examples of determination of the basic control...

  7. State of Charge Balancing Control of a Multi-Functional Battery Energy Storage System Based on a 11-Level Cascaded Multilevel PWM Converter

    DEFF Research Database (Denmark)

    Wang, Songcen; Teodorescu, Remus; Máthé, Lászlo

    2015-01-01

    This paper focuses on modeling and SOC (State of Charge) balancing control of lithium-ion battery energy storage system based on cascaded multilevel converter for both grid integration and electric vehicle propulsion applications. The equivalent electrical circuit model of lithium-ion battery...

  8. Using variable DC sources in order to improve the voltage quality of a multilevel STATCOM with low frequency modulation

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Najjar, Mohammad; Blaabjerg, Frede

    2016-01-01

    In this paper, a Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) method, which utilizes adjustable dc links, is presented for a Static Synchronous Compensator (STATCOM) based on Cascaded H-Bridge (CHB) multilevel converter. The proposed switching algorithm is able to fix the capac......In this paper, a Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) method, which utilizes adjustable dc links, is presented for a Static Synchronous Compensator (STATCOM) based on Cascaded H-Bridge (CHB) multilevel converter. The proposed switching algorithm is able to fix...... unequal dc link voltages more levels at the output is achievable compared to the symmetrical multilevel converters that could be used in enhancing the power quality, while keeping the switching frequency near the fundamental (the maximum switching frequency can be kept below 150 Hz). The validity...

  9. The Economic Impact of Bucks County Community College on the Local Economy During Fiscal Year 1978-79.

    Science.gov (United States)

    Mahon, Jack

    The effects of Bucks County Community College (BCCC) on the local economy during fiscal year (FY) 1979 were investigated in terms of the monies spent in operating BCCC through purchases of goods and services, salaries to college employees, student financial aid expenditures, veterans' benefits, and property taxes paid by college employees, as well…

  10. NOAA TIFF Graphic- 0.5m Backscatter Mosaic of St. Croix (Buck Island), US Virgin Islands, 2005 (NCEI Accession 0131860)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a 1 meter resolution backscatter mosaic of the north shore of Buck Island, St. Croix, US Virgin Islands.NOAA's NOS/NCCOS/CCMA Biogeography Team...

  11. Experimental Results of a DC Bus Voltage Level Control for a Load-Controlled Marine Current Energy Converter

    Directory of Open Access Journals (Sweden)

    Johan Forslund

    2015-05-01

    Full Text Available This paper investigates three load control methods for a  marine current energy converter using a vertical axis current  turbine (VACT mounted on a permanent magnet synchronous generator  (PMSG. The three cases are; a fixed AC load, a fixed pulse width  modulated (PWM DC load and DC bus voltage control of a DC  load. Experimental results show that the DC bus voltage control  reduces the variations of rotational speed by a factor of 3.5 at the cost  of slightly increased losses in the generator and transmission lines.  For all three cases, the tip speed ratio \\(\\lambda\\ can be kept close to  the expected \\(\\lambda_{opt}\\. The power coefficient is estimated to be  0.36 at \\(\\lambda_{opt}\\; however, for all three cases, the average  extracted power was about \\(\\sim 19\\\\%. A maximum power point  tracking (MPPT system, with or without water velocity measurement,  could increase the average extracted power.

  12. Development of residential solar air conditioning system for electricity power peak cut 3

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Gwon Jong [Korea Inst. of Energy and Resources, Daeduk (Korea, Republic of)

    1995-12-31

    In this research, the converter rectifier unit of the inverter air conditioner is substituted into the bidirectional PWM converter. The DC/DC power converter is established on the DC link between the photovoltaic array and the inverter air conditioner, and the photovoltaic air conditioning system which can be parallel driven which utility is developed. (author). 35 ref., 112 figs.

  13. Three-Phase High-Power and Zero-Current-Switching OBC for Plug-In Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Cheng-Shan Wang

    2015-06-01

    Full Text Available In this paper, an interleaved high-power zero-current-switching (ZCS onboard charger (OBC based on the three-phase single-switch buck rectifier is proposed for application to plug-in electric vehicles (EVs. The multi-resonant structure is used to achieve high efficiency and high power density, which are necessary to reduce the volume and weight of the OBC. This study focuses on the border conditions of ZCS converting with a battery load, which means the variation ranges of the output voltage and current are very large. Furthermore, a novel hybrid control method combining pulse frequency modulation (PFM and pulse width modulation (PWM together is presented to ensure a driving frequency higher than 10 kHz, and this will reduce the unexpected inner resonant power flow and decrease the total harmonic distortion (THD of the input current under a light load at the end of the charging process. Finally, a prototype is established, and experiments are carried out. According to the experimental results, the conversion efficiency is higher than 93.5%, the THD about 4.3% and power factor (PF 0.98 under the maximum power output condition. Besides, a three-stage charging process is also carried out the experimental platform.

  14. User's design handbook for a Standardized Control Module (SCM) for DC to DC Converters, volume 2

    Science.gov (United States)

    Lee, F. C.

    1980-01-01

    A unified design procedure is presented for selecting the key SCM control parameters for an arbitrarily given power stage configuration and parameter values, such that all regulator performance specifications can be met and optimized concurrently in a single design attempt. All key results and performance indices, for buck, boost, and buck/boost switching regulators which are relevant to SCM design considerations are included to facilitate frequent references.

  15. EFFECT OF VITAMIN E ON SPERM AND OXIDATIVE STRESS PARAMETERS OF WEST AFRICAN DWARF GOAT BUCKS

    Directory of Open Access Journals (Sweden)

    James Olamitibo Daramola

    2016-08-01

    Full Text Available The aim of the present study was to determine the effect of supplementation of vitamin E on sperm and oxidative stress parameters in West African Dwarf goat bucks. The bucks were allocated to 4 treatments consisting of 0 mg, 15 mg, 30 mg and 45 mg of vitamin E. At the end of 30 days consecutive administration of vitamin E, semen and blood samples were collected and evaluated for sperm and oxidative stress parameters. The results showed that sperm motility, acrosome integrity, membrane integrity and live spermatozoa; seminal Malondialdehyde (MDA, arginase activity and leukocytes; and serum MDA and testosterone were similar in all the levels of inclusion and comparable to the control. However, higher arginase activities were observed in all the levels of vitamin E compared to the control while 15 mg of vitamin E had higher percentage of sperm abnormality compared to other treatments and the control. The findings indicated that the levels of vitamin E used did not have beneficial effect on the sperm and oxidative stress parameters. Further study of higher levels of vitamin E is therefore necessary to ascertain the appropriate level required for optimal improvement in these parameters.

  16. Grid Connected WECS with A Five Level DCMLI using PID Controller

    Directory of Open Access Journals (Sweden)

    G.Balaji

    2014-07-01

    Full Text Available This paper deals with the analysis, modeling and control system for permanent magnet synchronous generator (PMSG based wind turbine connected to the grid. A wind energy conversion using DC-DC Buck- Boost Converter for permanent magnet synchronous generator (PMSG based variable speed wind energy conversion system (WECS has been proposed which is integrated with grid using five-level diode clamped multilevel (DCMLI inverter. In this work the instantaneous values of input side current and voltage of DC-DC buck-boost converter are utilized for implementing the PID controller. The proposed work is verified by the simulation in Powersim.

  17. Integrating DC/DC Conversion with Possible Reconfiguration within Submodule Solar Photovoltaic Systems

    Science.gov (United States)

    Huang, Peter Jen-Hung

    This research first proposes a method to merge photovoltaic (PV) cells or PV panels within the internal components DC-DC converters. The purpose of this merged structure is to reconfigure the PV modules between series and parallel connections using high switching frequencies (hundreds of kHz). This leads to multi-levels of voltages and currents that become applied to the output filter of the converter. Further, this research introduces a concept of a switching cell that utilizes the reconfiguration of series and parallel connections in DC-DC converters. The switching occurs at high switching frequency and the switches can be integrated to be within the solar panels or in between the solar cells. The concept is generalized and applied to basic buck and boost topologies. As examples of the new types of converters: reconfigurable PV-buck and PV-boost converter topologies are presented. It is also possible to create other reconfigurable power converters: non-isolated and isolated topologies. Analysis, simulation and experimental verification for the reconfigurable PV-buck and PV-boost converters are presented extensively to illustrate proof of concept. Benefits and drawbacks of the new approach are discussed. The second part of this research proposes to utilize the internal solar cell capacitance and internal solar module wire parasitic inductances to replace the input capacitor and filter inductor in boost derived DC-DC converters for energy harvesting applications. High switching frequency (MHz) hard switched and resonant boost converters are proposed. Their analysis, simulation and experimental prototypes are presented. A specific proof-of-concept application is especially tested for foldable PV panels, which are known for their high internal wire inductance. The experimental converters successfully boost solar module voltage without adding any external input capacitance or filter inductor. Benefits and drawbacks of new proposed PV submodule integrated boost

  18. Szász-Durrmeyer operators involving Boas-Buck polynomials of blending type.

    Science.gov (United States)

    Sidharth, Manjari; Agrawal, P N; Araci, Serkan

    2017-01-01

    The present paper introduces the Szász-Durrmeyer type operators based on Boas-Buck type polynomials which include Brenke type polynomials, Sheffer polynomials and Appell polynomials considered by Sucu et al. (Abstr. Appl. Anal. 2012:680340, 2012). We establish the moments of the operator and a Voronvskaja type asymptotic theorem and then proceed to studying the convergence of the operators with the help of Lipschitz type space and weighted modulus of continuity. Next, we obtain a direct approximation theorem with the aid of unified Ditzian-Totik modulus of smoothness. Furthermore, we study the approximation of functions whose derivatives are locally of bounded variation.

  19. Szász-Durrmeyer operators involving Boas-Buck polynomials of blending type

    Directory of Open Access Journals (Sweden)

    Manjari Sidharth

    2017-05-01

    Full Text Available Abstract The present paper introduces the Szász-Durrmeyer type operators based on Boas-Buck type polynomials which include Brenke type polynomials, Sheffer polynomials and Appell polynomials considered by Sucu et al. (Abstr. Appl. Anal. 2012:680340, 2012. We establish the moments of the operator and a Voronvskaja type asymptotic theorem and then proceed to studying the convergence of the operators with the help of Lipschitz type space and weighted modulus of continuity. Next, we obtain a direct approximation theorem with the aid of unified Ditzian-Totik modulus of smoothness. Furthermore, we study the approximation of functions whose derivatives are locally of bounded variation.

  20. GeoTIFF of 3x3 m Bathymetry for Buck Island, St. Croix, 2011, UTM 20N NAD83 (NCEI Accession 0131858)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a LiDAR (Light Detection & Ranging) 3x3 meter resolution bathymetric surface for an area including and surrounding Buck Island Reef...

  1. Vector control of three-phase AC/DC front-end converter

    Indian Academy of Sciences (India)

    Section 4 presents the simulation and experimental results of FEC. Section 5 discusses the problems associated with the starting process of ..... A 250-kVA vector-controlled FEC is simulated with MATLAB/SIMULINK. ..... Ghosh R 2007 Modelling, Analysis and Control of Single-phase and Three-phase PWM Rectifiers.

  2. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    Science.gov (United States)

    Afiqah Zainal, Nurul; Sooi Tat, Chan; Ajisman

    2016-02-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's ou tput is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor.

  3. Improved power quality based high brightness LED lamp driver

    African Journals Online (AJOL)

    user

    consists of a PFC Cuk DC-DC converter which operates in continuous conduction mode (CCM) to improve the ... In proposed LED driver as shown in Figure 1, a Cuk buck boost AC-DC converter ... Design and Analysis of Proposed LED Driver.

  4. Novel Family of modified qZS buck-boost multilevel inverters with reduced switch count

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Strzelecki, Ryszard; Blaabjerg, Frede

    2015-01-01

    This paper describes a novel family of modified quasi-Z-source buck-boost multilevel inverters with reduced switch count. The inverters are derived by means of the modified inverter configuration with quasi-Z-source networks. The main benefits of the proposed solutions lie in the increased amount...... of levels with all possible sequences: reduced THD, reduced voltage stress on the transistors and size of the output filter. Also their modulation techniques are proposed and described. Simulation results have confirmed all theoretical predictions. The pros and cons are discussed in the conclusions....

  5. Modeling and simulation of stand-alone hybrid power system with fuzzy MPPT for remote load application

    Directory of Open Access Journals (Sweden)

    Bogaraj T.

    2015-09-01

    Full Text Available Many parts of remote locations in the world are not electrified even in this Advanced Technology Era. To provide electricity in such remote places renewable hybrid energy systems are very much suitable. In this paper PV/Wind/Battery Hybrid Power System (HPS is considered to provide an economical and sustainable power to a remote load. HPS can supply the maximum power to the load at a particular operating point which is generally called as Maximum Power Point (MPP. Fuzzy Logic based MPPT (FLMPPT control method has been implemented for both Solar and Wind Power Systems. FLMPPT control technique is implemented to generate the optimal reference voltage for the first stage of DC-DC Boost converter in both the PV and Wind energy system. The HPS is tested with variable solar irradiation, temperature, and wind speed. The FLMPPT method is compared with P&O MPPT method. The proposed method provides a good maximum power operation of the hybrid system at all operating conditions. In order to combine both sources, the DC bus voltage is made constant by employing PI Controllers for the second stage of DC-DC Buck-Boost converter in both Solar and Wind Power Systems. Battery Bank is used to store excess power from Renewable Energy Sources (RES and to provide continuous power to load when the RES power is less than load power. A SPWM inverter is designed to convert DC power into AC to supply three phase load. An LC filter is also used at the output of inverter to get sinusoidal current from the PWM inverter. The entire system was modeled and simulated in Matlab/Simulink Environment. The results presented show the validation of the HPS design.

  6. GeoTIFF of 3x3 m Relative Reflectivity for Buck Island, St. Croix, 2011, UTM 20N NAD83 (NCEI Accession 0131858)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This image represents a LiDAR (Light Detection & Ranging) 3x3 meter resolution relative seafloor reflectivity surface for an area including and surrounding Buck...

  7. A Method of Maximum Power Control in Single-phase Utility Interactive Photovoltaic Generation System by using PWM Current Source Inverter

    Science.gov (United States)

    Neba, Yasuhiko

    This paper deals with a maximum power point tracking (MPPT) control of the photovoltaic generation with the single-phase utility interactive inverter. The photovoltaic arrays are connected by employing the PWM current source inverter to the utility. The use of the pulsating dc current and voltage allows the maximum power point to be searched. The inverter can regulate the array voltage and keep the arrays to the maximum power. This paper gives the control method and the experimental results.

  8. Modeling, Dynamics, Bifurcation Behavior and Stability Analysis of a DC-DC Boost Converter in Photovoltaic Systems

    Science.gov (United States)

    Zhioua, M.; El Aroudi, A.; Belghith, S.; Bosque-Moncusí, J. M.; Giral, R.; Al Hosani, K.; Al-Numay, M.

    A study of a DC-DC boost converter fed by a photovoltaic (PV) generator and supplying a constant voltage load is presented. The input port of the converter is controlled using fixed frequency pulse width modulation (PWM) based on the loss-free resistor (LFR) concept whose parameter is selected with the aim to force the PV generator to work at its maximum power point. Under this control strategy, it is shown that the system can exhibit complex nonlinear behaviors for certain ranges of parameter values. First, using the nonlinear models of the converter and the PV source, the dynamics of the system are explored in terms of some of its parameters such as the proportional gain of the controller and the output DC bus voltage. To present a comprehensive approach to the overall system behavior under parameter changes, a series of bifurcation diagrams are computed from the circuit-level switched model and from a simplified model both implemented in PSIM© software showing a remarkable agreement. These diagrams show that the first instability that takes place in the system period-1 orbit when a primary parameter is varied is a smooth period-doubling bifurcation and that the nonlinearity of the PV generator is irrelevant for predicting this phenomenon. Different bifurcation scenarios can take place for the resulting period-2 subharmonic regime depending on a secondary bifurcation parameter. The boundary between the desired period-1 orbit and subharmonic oscillation resulting from period-doubling in the parameter space is obtained by calculating the eigenvalues of the monodromy matrix of the simplified model. The results from this model have been validated with time-domain numerical simulation using the circuit-level switched model and also experimentally from a laboratory prototype. This study can help in selecting the parameter values of the circuit in order to delimit the region of period-1 operation of the converter which is of practical interest in PV systems.

  9. AC-DC PFC Converter Using Combination of Flyback Converter and Full-bridge DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Moh. Zaenal Efendi

    2014-06-01

    Full Text Available This paper presents a combination of power factor correction converter using Flyback converter and Full-bridge dc-dc converter in series connection. Flyback converter is operated in discontinuous conduction mode so that it can serve as a power factor correction converter and meanwhile Full-bridge dc-dc converter is used for dc regulator. This converter system is designed to produce a 86 Volt of output voltage and 2 A of output current. Both simulation and experiment results show that the power factor of this converter achieves up to 0.99 and meets harmonic standard of IEC61000-3-2. Keywords: Flyback Converter, Full-bridge DC-DC Converter, Power Factor Correction.

  10. Internal-Model-Principle-Based Specific Harmonics Repetitive Controller for Grid-Connected PWM Inverters

    Directory of Open Access Journals (Sweden)

    Wenzhou Lu

    2016-01-01

    Full Text Available This paper analyzes the general properties of IMP-based controller and presents an internal-model-principle-based (IMP-based specific harmonics repetitive control (SHRC scheme. The proposed SHRC is effective for specific nk±m order harmonics, with n>m≥0 and k=0,1,2,…. Using the properties of exponential function, SHRC can also be rewritten into the format of multiple resonant controllers in parallel, where the control gain of SHRC is n/2 multiple of that of conventional RC (CRC. Therefore, including SHRC in a stable closed-loop feedback control system, asymptotic disturbance eliminating, or reference tracking for any periodic signal only including these specific harmonic components at n/2 times faster error convergence rate compared with CRC can be achieved. Application examples of SHRC controlled three-phase/single-phase grid-connected PWM inverters demonstrate the effectiveness and advantages of the proposed SHRC scheme.

  11. High performance current controller for particle accelerator magnets supply

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Bidoggia, Benoit; Munk-Nielsen, Stig

    2013-01-01

    The electromagnets in modern particle accelerators require high performance power supply whose output is required to track the current reference with a very high accuracy (down to 50 ppm). This demands very high bandwidth controller design. A converter based on buck converter topology is used...

  12. Modelling and characterization of the PEM fuel cell to study interactions with power converters; Modelisation et caracterisation de la pile pem pour l'etude des interactions avec les convertisseurs statiques

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, G

    2005-09-15

    The climatic and energy challenges were now clearly stated. The use of hydrogen is one of the best ways which gives many hopes. Fuel cells are an essential link in the chain of the use of hydrogen. Thus, a lot of studies have been undertaken throughout the world on fuel cells in many fields of physics. Concerning the field of power electronics, a lot of work on distributed generation technologies using fuel cells has been realised too and a great number of power converters dedicated to fuel cells have been studied. However, very few studies have been undertaken on the interactions between fuel cells and power converters. The goals of this work are to study interactions between fuel cells and power converters. Some requirements for the power electronic engineer can follow from this work. This work proposes high signal dynamic models of a H{sub 2}/O{sub 2} PEM fuel cell. These models include the different physical and chemical phenomena. Specific methods based on a limited number of original experiments (low frequency current sweeps) allow to extract the model parameters. These models are used to study the interactions between fuel cells and power converters which are the most used: buck chopper, boost chopper, inverters. The important part of the double layer capacitors has thus been underlined: they can filter the current harmonics created by the power converters. Finally, some choices of filtering elements to be connected to the fuel cell are proposed. (author)

  13. NOAA ESRI Grid- 5m Multibeam Bathymetry of St. Croix (Buck Island), US Virgin Islands, Project NF-05-05, 2005, UTM 20 NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains an ESRI Grid with 5 meter cell size representing the bathymetry of the north shore of St. Croix (Buck Island), US Virgin Islands.NOAA's...

  14. NOAA ESRI Geotiff- 1m Multibeam Bathymetry of St. Croix (Buck Island), US Virgin Islands, Project NF-05-05, 2005, UTM 20 NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains an ESRI Geotiff with 1 meter cell size representing the bathymetry of the north shore of St. Croix (Buck Island), US Virgin Islands.NOAA's...

  15. A simplified time-domain design and implementation of cascaded PI ...

    Indian Academy of Sciences (India)

    LENIN PRAKASH

    Performance analysis based on field test results using real-time weather data validates the proposed design. ... applications such as photovoltaic (PV) solar systems, fuel cells, etc. ...... 2001 Averaged modeling of PWM converters operating in.

  16. Modelling and characterization of the PEM fuel cell to study interactions with power converters; Modelisation et caracterisation de la pile pem pour l'etude des interactions avec les convertisseurs statiques

    Energy Technology Data Exchange (ETDEWEB)

    Fontes, G.

    2005-09-15

    The climatic and energy challenges were now clearly stated. The use of hydrogen is one of the best ways which gives many hopes. Fuel cells are an essential link in the chain of the use of hydrogen. Thus, a lot of studies have been undertaken throughout the world on fuel cells in many fields of physics. Concerning the field of power electronics, a lot of work on distributed generation technologies using fuel cells has been realised too and a great number of power converters dedicated to fuel cells have been studied. However, very few studies have been undertaken on the interactions between fuel cells and power converters. The goals of this work are to study interactions between fuel cells and power converters. Some requirements for the power electronic engineer can follow from this work. This work proposes high signal dynamic models of a H{sub 2}/O{sub 2} PEM fuel cell. These models include the different physical and chemical phenomena. Specific methods based on a limited number of original experiments (low frequency current sweeps) allow to extract the model parameters. These models are used to study the interactions between fuel cells and power converters which are the most used: buck chopper, boost chopper, inverters. The important part of the double layer capacitors has thus been underlined: they can filter the current harmonics created by the power converters. Finally, some choices of filtering elements to be connected to the fuel cell are proposed. (author)

  17. Phase shift PWM with double two-switch bridge for high power capacitor charging

    International Nuclear Information System (INIS)

    Karandikar, U.S.; Singh, Yashpal; Thakurta, A.C.

    2013-01-01

    Pulse power supply systems working at higher voltage and high repetition rate demands for higher power from capacitor chargers. Capacitor charging requirement become more challenging in such cases. In pulse power circuits, energy storage capacitor should be charged to its desired voltage before the next switching occurs. It is discharged within a small time, delivering large pulse power. A capacitor charger has to work with wide load variation repeatedly. Many schemes are used for this purpose. The proposed scheme aims at reducing stresses on switches by reducing peak current and their evils. A high voltage power supply is designed for capacitor charging. The proposed scheme is based on a Phase-Shifted PWM without using any extra component to achieve soft switching. Indirect constant average current capacitor charging is achieved with a simple control scheme. A double two-switch bridge is proposed to enhance reliability. Power supply has been developed to charge a capacitor of 50 μF to 2.5 kV at 25 Hz. (author)

  18. Fuzzy Logic Controlled Solar Module for Driving Three- Phase Induction Motor

    International Nuclear Information System (INIS)

    Zainal, Nurul Afiqah; Tat, Chan Sooi; Ajisman

    2016-01-01

    Renewable energy produced by solar module gives advantages for generated three- phase induction motor in remote area. But, solar module's output is uncertain and complex. Fuzzy logic controller is one of controllers that can handle non-linear system and maximum power of solar module. Fuzzy logic controller used for Maximum Power Point Tracking (MPPT) technique to control Pulse-Width Modulation (PWM) for switching power electronics circuit. DC-DC boost converter used to boost up photovoltaic voltage to desired output and supply voltage source inverter which controlled by three-phase PWM generated by microcontroller. IGBT switched Voltage source inverter (VSI) produced alternating current (AC) voltage from direct current (DC) source to control speed of three-phase induction motor from boost converter output. Results showed that, the output power of solar module is optimized and controlled by using fuzzy logic controller. Besides that, the three-phase induction motor can be drive and control using VSI switching by the PWM signal generated by the fuzzy logic controller. This concluded that the non-linear system can be controlled and used in driving three-phase induction motor. (paper)

  19. Chaotic Behavior in a Switched Dynamical System

    Directory of Open Access Journals (Sweden)

    Fatima El Guezar

    2008-01-01

    Full Text Available We present a numerical study of an example of piecewise linear systems that constitute a class of hybrid systems. Precisely, we study the chaotic dynamics of the voltage-mode controlled buck converter circuit in an open loop. By considering the voltage input as a bifurcation parameter, we observe that the obtained simulations show that the buck converter is prone to have subharmonic behavior and chaos. We also present the corresponding bifurcation diagram. Our modeling techniques are based on the new French native modeler and simulator for hybrid systems called Scicos (Scilab connected object simulator which is a Scilab (scientific laboratory package. The followed approach takes into account the hybrid nature of the circuit.

  20. A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade

    CERN Document Server

    Feld, Lutz Werner; Marcel Friedrichs; Richard Hensch; Karpinski, Waclaw; Klein, Katja; Sammet, Jan Domenik; Wlochal, Michael

    2012-01-01

    The powering scheme of the CMS pixel detector will be described, and the performance of prototype DC-DC buck converters will be presented, including power efficiency, system tests with DC-DC converters and pixel modules, thermal management, reliability at low temperature, and studies of potential frequency locking betwe...

  1. Residence time, chemical and isotopic analysis of nitrate in the groundwater and surface water of a small agricultural watershed in the Coastal Plain, Bucks Branch, Sussex County, Delaware

    Science.gov (United States)

    Clune, John W.; Denver, Judith M.

    2012-01-01

    Nitrate is a common contaminant in groundwater and surface water throughout the Nation, and water-resource managers need more detailed small-scale watershed research to guide conservation efforts aimed at improving water quality. Concentrations of nitrate in Bucks Branch are among the highest in the state of Delaware and a scientific investigation was performed to provide water-quality information to assist with the management of agriculture and water resources. A combination of major-ion chemistry, nitrogen isotopic composition and age-dating techniques was used to estimate the residence time and provide a chemical and isotopic analysis of nitrate in the groundwater in the surficial aquifer of the Bucks Branch watershed in Sussex County, Delaware. The land use was more than 90 percent agricultural and most nitrogen inputs were from manure and fertilizer. The apparent median age of sampled groundwater is 18 years and the estimated residence time of groundwater contributing to the streamflow for the entire Bucks Branch watershed at the outlet is approximately 19 years. Concentrations of nitrate exceeded the U.S. Environmental Protection Agency drinking-water standard of 10 milligrams per liter (as nitrogen) in 60 percent of groundwater samples and 42 percent of surface-water samples. The overall geochemistry in the Bucks Branch watershed indicates that agriculture is the predominant source of nitrate contamination and the observed patterns in major-ion chemistry are similar to those observed in other studies on the Mid-Atlantic Coastal Plain. The pattern of enrichment in nitrogen and oxygen isotopes (δ15N and δ18O) of nitrate in groundwater and surface water indicates there is some loss of nitrate through denitrification, but this process is not sufficient to remove all of the nitrate from groundwater discharging to streams, and concentrations of nitrate in streams remain elevated.

  2. a generalized approach to analysing a class of passively soft ...

    African Journals Online (AJOL)

    NIJOTECH

    The use of this circuit cell to transform the basic hard switched converters (buck, boost, bucklboost, Cuk's, Sepic and Zeta) into their varied ... The switching losses of the conventional hard- switched dc to dc converter increase with ... circuit reactive components for a given power output. Some proposals have been made to.

  3. Diseño estático de un convertidor DC/DC reductor-elevador bidireccional

    Directory of Open Access Journals (Sweden)

    Marcela González Valencia

    2010-06-01

    Full Text Available This paper shows a buck-boost converter static design with 3 switches and cascade connection. The main application of the converter is the battery management on uninterruptible power supplies, cotrolling energy flow and regulating the DC supply voltage for the different battery operation modes as source and sink.

  4. Vibration and acoustic noise emitted by dry-type air-core reactors under PWM voltage excitation

    Science.gov (United States)

    Li, Jingsong; Wang, Shanming; Hong, Jianfeng; Yang, Zhanlu; Jiang, Shengqian; Xia, Shichong

    2018-05-01

    According to coupling way between the magnetic field and the structural order, structure mode is discussed by engaging finite element (FE) method and both natural frequency and modal shape for a dry-type air-core reactor (DAR) are obtained in this paper. On the basis of harmonic response analysis, electromagnetic force under PWM (Pulse Width Modulation) voltage excitation is mapped with the structure mesh, the vibration spectrum is gained and the consequences represents that the whole structure vibration predominates in the radial direction, with less axial vibration. Referring to the test standard of reactor noise, the rules of emitted noise of the DAR are measured and analyzed at chosen switching frequency matches the sample resonant frequency and the methods of active vibration and noise reduction are put forward. Finally, the low acoustic noise emission of a prototype DAR is verified by measurement.

  5. interval type-2 fuzzy gain-adaptive controller of a doubly fed

    African Journals Online (AJOL)

    Loukal K and Benalia L

    2016-05-01

    May 1, 2016 ... machine a converter PWM (Pulse Width Modulation) between the machine ... operations on fuzzy sets increases with the increasing type of the fuzzy set. ...... Several simulations have been run using the Matlab and Simulink® ...

  6. Method and device for current driven electric energy conversion

    DEFF Research Database (Denmark)

    2012-01-01

    Device comprising an electric power converter circuit for converting electric energy. The converter circuit comprises a switch arrangement with two or more controllable electric switches connected in a switching configuration and controlled so as to provide a current drive of electric energy from...... configurations such as half bridge buck, full bridge buck, half bridge boost, or full bridge boost. A current driven conversion is advantageous for high efficient energy conversion from current sources such as solar cells or where a voltage source is connected through long cables, e.g. powerline cables for long...... an associated electric source connected to a set of input terminals. This is obtained by the two or more electric swiches being connected and controlled to short-circuit the input terminals during a part of a switching period. Further, a low pass filter with a capacitor and an inductor are provided to low pass...

  7. A comparative investigation of three PM-less MW power range wind generator topologies

    DEFF Research Database (Denmark)

    Bratiloveanu, Catalin-Rauti; Traian Cosmin Anghelus, Dumitru; Boldea, I.

    2012-01-01

    As the wind energy penetration range increases steadily and the high energy PM costs are rising dramatically, PM-less large power wind generators with high performance are needed. Apart from extending the range of cage rotor induction generators, doubly-fed induction generators and dc excited...... investigates by quasi 2D-FEM two dc stator polarized (to increase machine side PWM converter voltage utilization, that is to reduce peak kVA ratings and costs of the machine side PWM converter) directly-driven switched reluctance generators (one with circumferential field and one with transverse flux (with...... heteropolar-rotor (standard) synchronous generators, especially for direct drives (very low speed) and multibrid (with single stage transmission (5/1-8/1 ratio)), new topologies have to be investigated to reduce initial costs and weights for high enough efficiency and energy annual yield. The present paper...

  8. A comparative design view for accurate control of servos using a field programmable gate array

    International Nuclear Information System (INIS)

    Tickle, A J; Harvey, P K; Smith, J S; Wu, F; Buckle, J R

    2009-01-01

    An embedded system is a special-purpose computer system designed to perform one or a few dedicated functions. Altera DSP Builder presents designers and users with an alternate approach when creating their systems by employing a blockset similar to that already used in Simulink. The application considered in this paper is the design of a Pulse Width Modulation (PWM) system for use in stereo vision. PWM can replace a digital-to-analogue converter to control audio speakers, LED intensity, motor speed, and servo position. Rather than the conventional HDL coding approach this Simulink approach provides an easy understanding platform to the PWM design. This paper includes a comparison between two approaches regarding resource usage and flexibility etc. Included is how DSP Builder manipulates an onboard clock signal, in order to create the control pulses to the 'raw' coding of a PWM generator in VHDL. Both methods were shown to a selection of people and their views on which version they would subsequently use in their relative fields is discussed.

  9. NOS ESRI Grid, Unified 10m Multibeam Bathymetry La Parguera, Puerto Rico and Buck Island, St. Croix 2006: Project NF-06-03, UTM 20 NAD83

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains a unified ESRI Grid with 10 meter cell size representing the bathymetry of selected portions of seafloor around La Parguera, P.R. and Buck...

  10. Power decoupling method for single phase differential buck converter

    DEFF Research Database (Denmark)

    Yao, Wenli; Tang, Yi; Zhang, Xiaobin

    2015-01-01

    inverter to improve the dc link power quality, and an improved active power decoupling method is proposed to achieve ripple power reduction for both AC-DC and DC-AC conversions. The ripple energy storage is realized by the filter capacitors, which are connected between the output terminal and the negative...... generation technique is proposed to provide accurate ripple power compensation, and closed-loop controllers are also designed based on small signal models. The effectiveness of this power decoupling method is verified by detailed simulation studies as well as laboratory prototype experimental results....... dc bus. By properly controlling the differential mode voltage of the capacitors, it is possible to transfer desired energy between the DC port and AC port. The common mode voltage is controlled in such a way that the ripple power on the dc side will be reduced. Furthermore, an autonomous reference...

  11. Implementation of a PV lighting system based on DC-DC converter with intelligent controlled approach

    Energy Technology Data Exchange (ETDEWEB)

    Hua, C.-C.; Chuang, D.-J. [National Yunlin Univ. of Science and Technology, Douliou, Yunlin, Taiwan (China). Dept. of Electrical Engineering; Chuang, C.-W. [National Yunlin Univ. of Science and Technology, Douliou, Yunlin, Taiwan (China). Graduate School of Engineering Science and Technology

    2007-07-01

    Photovoltaic (PV) lighting systems for municipalities represent one of the largest cost effective markets for PVs. The installation cost of just one or two utility power poles can justify the initial cost of a PV lighting system. However, many previous PV lighting systems have experienced a number of component failures including premature charge controller, battery, and ballast illumination failures. This paper presented the design and implementation of a digital high performance photovoltaic lighting system based on a microcontroller. A high brightness light-emitting diode (HBLED), was used as it can work at very high efficiency with a specially designed lighting power module. The proposed system consisted of a photovoltaic module, a light emitting diode (LED) lighting module, a bi-directional buck-boost converter and a battery. The paper analysed battery charging methods and proposed a control strategy and hardware implementation. The dimming control methods for LED were also discussed and compared. The experimental results were also provided to verify the theoretical analysis and design procedure of a digital controlled photovoltaic lighting system. It was concluded that the experimental results verified the performance of the proposed photovoltaic lighting system. 8 refs., 1 tab., 18 figs.

  12. Physiological response and semen quality of rabbit bucks supplemented with Moringa leaves ethanolic extract during summer season.

    Science.gov (United States)

    El-Desoky, N I; Hashem, N M; Elkomy, A; Abo-Elezz, Z R

    2017-09-01

    Exposure of rabbit bucks to summer heat stress reduces their homeostasis and semen quality leading to a temporal subfertility. The potentiality of ethanolic extract of Moringa oleifera leaves (M. oleifera ethanolic extract (MLEE)) to reduce negative impacts of heat stress on physiological and semen quality traits was investigated. A total of 28 adult V-line rabbit bucks were randomly distributed among four experimental groups of seven rabbits each. The first group received water (placebo) and served as a control (M0). The other three groups were given orally MLEE at levels of 50 (M50), 100 (M100) and 150 (M150) mg/kg BW every other day for 12 consecutive weeks during the summer season. Chemical constituents of MLEE were detected by gas chromatography/MS. During the experimental period, ambient temperature and relative humidity were recorded daily and were used to estimate temperature and humidity index. Feed intake, BW, rectal temperature were recorded and blood serum biochemical attributes were determined. Semen samples were collected weekly and were analyzed for semen quality traits. Results showed that MLEE contained high percentages of long-chain fatty acids and antioxidant agents. Feed intake and BW were not affected significantly by the treatment, however rectal temperature was decreased significantly by 0.42°C, 0.24°C and 0.40°C in the M50, M100 and M150 groups, respectively, compared with the M0 group. Treatment with 50 mg/kg BW increased concentration of serum albumin (115%; P<0.05), total antioxidant capacity (132%; P<0.05) and testosterone (160%; P=0.098) as well as seminal plasma initial fructose (127%; P=0.092) compared with the control group. Compared with the control, MLEE supplementation with 50, 100 and 150 mg/kg BW increased significantly sperm concentration by 118%, 151% and 158%, sperm progressive motility by 117%, 120% and 118%, sperm viability by 129%, 137% and 127%, sperm normal morphology by 114%, 113% and 114%, intact acrosome sperm by

  13. A CMOS/SOI Single-input PWM Discriminator for Low-voltage Body-implanted Applications

    Directory of Open Access Journals (Sweden)

    Jader A. De Lima

    2002-01-01

    Full Text Available A CMOS/SOI circuit to decode Pulse-Width Modulation (PWM signals is presented as part of a body-implanted neurostimulator for visual prosthesis. Since encoded data is the sole input to the circuit, the decoding technique is based on a novel double-integration concept and does not require low-pass filtering. Non-overlapping control phases are internally derived from the incoming pulses and a fast-settling comparator ensures good discrimination accuracy in the megahertz range. The circuit was integrated on a 2 μm single-metal thin-film CMOS/SOI fabrication process and has an effective area of 2 mm2. Measured resolution of encoding parameter α is better than 10% at 6 MHz and VDD = 3.3 V. Idle-mode consumption is 340 μW. Pulses of frequencies up to15 MHz and α =10% can be discriminated for 2.3 V ≤ VDD ≤ 3.3 V. Such an excellent immunity to VDD deviations meets a design specification with respect to inherent coupling losses on transmitting data and power by means of a transcutaneous link.

  14. Performance evaluation of a DC-AC inverter controlled with ZAD-FPIC

    Directory of Open Access Journals (Sweden)

    Fredy Edimer Hoyos Velasco

    2018-01-01

    Full Text Available Introduction: Power converters are used in microgrids to transfer power to the load with a regulated voltage. However, the DC-AC converters present distortions in the waveform that can be improved with the help of real-time controllers. Objective: Evaluate the response in alternating current of the buck converter controlled using ZAD-FPIC technique. Methodology: Based on the differential equations that describe the buck power converter, the ZAD and FPIC controllers are designed, simulations of the complete controlled system are made in Simulink of MATLAB, the system is implemented experimentally, and the controller is executed in real-time with the help of a DS1104 from dSPACE. In the end, several tests are carried out to check the effectiveness of the controller. Results: The results show that the controller allows good stability against different variations in the system and in the load. Conclusions: The ZAD-FPIC technique controls the variable and tracks changes in the waveform, magnitude, and frequency of the reference signal. The controller presents good stability to different tests, tracking the reference signal after each event.

  15. An Optimal Control Strategy for DC Bus Voltage Regulation in Photovoltaic System with Battery Energy Storage

    Directory of Open Access Journals (Sweden)

    Muhamad Zalani Daud

    2014-01-01

    Full Text Available This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV system with battery energy storage (BES. The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC. For the grid side VSC (G-VSC, two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.

  16. An optimal control strategy for DC bus voltage regulation in photovoltaic system with battery energy storage.

    Science.gov (United States)

    Daud, Muhamad Zalani; Mohamed, Azah; Hannan, M A

    2014-01-01

    This paper presents an evaluation of an optimal DC bus voltage regulation strategy for grid-connected photovoltaic (PV) system with battery energy storage (BES). The BES is connected to the PV system DC bus using a DC/DC buck-boost converter. The converter facilitates the BES power charge/discharge to compensate for the DC bus voltage deviation during severe disturbance conditions. In this way, the regulation of DC bus voltage of the PV/BES system can be enhanced as compared to the conventional regulation that is solely based on the voltage-sourced converter (VSC). For the grid side VSC (G-VSC), two control methods, namely, the voltage-mode and current-mode controls, are applied. For control parameter optimization, the simplex optimization technique is applied for the G-VSC voltage- and current-mode controls, including the BES DC/DC buck-boost converter controllers. A new set of optimized parameters are obtained for each of the power converters for comparison purposes. The PSCAD/EMTDC-based simulation case studies are presented to evaluate the performance of the proposed optimized control scheme in comparison to the conventional methods.

  17. NOAA ESRI Geotiff- 1m Multibeam Bathymetry of St. Croix (Buck Island), US Virgin Islands, Project NF-05-05, 2005, UTM 20 NAD83 (NCEI Accession 0131860)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains an ESRI Geotiff with 1 meter cell size representing the bathymetry of the north shore of St. Croix (Buck Island), US Virgin Islands.NOAA's...

  18. Effects of season and artificial photoperiod on semen and seminal plasma characteristics in bucks of two goat breeds maintained in a semen collection center

    Directory of Open Access Journals (Sweden)

    Francisco Arrebola

    2017-05-01

    Full Text Available Aim: This study quantified the effects of season and photoperiodic treatment on semen and seminal plasma (SP characteristics in 12 bucks of two Spanish goat breeds (Murciano-Granadina, and Payoya for the past 1 year. Materials and Methods: A total of 6 bucks (three of each breed were exposed to the natural day length and the other six males (three of each breed were exposed to alternating conditions of 2 months of long days (16 h light and 2 months of short days (8 h light. Weekly concentrations of glutamic oxaloacetic transaminase/aspartate aminotransferase (GOT/AST, lactate dehydrogenase (LDH, potassium, testosterone, and protein in SP were measured. Reaction time and scrotal circumference were recorded, and plasma testosterone concentrations were measured before semen collection. Results: Sperm volume, LDH, and potassium concentration in SP, and reaction time did not differ significantly between breeds, seasons, and photoperiodic treatment. Sperm concentrations were higher (p<0.001 in spring and summer than they were in autumn and winter. Mean percentage of positive hypo-osmotic swelling test sperm was the highest in summer and under the artificial photoperiod (p<0.01. GOT/AST concentrations differed (p<0.01 between breeds and seasons. Breed, season, and photoperiod had significant (p<0.001 effects on protein and testosterone levels in SP. Plasma testosterone concentrations were highest in summer (p<0.001, and differed significantly (p<0.01 between breeds. Scrotal perimeter differed significantly (p<0.001 between breeds and photoperiod. Conclusion: Recognition of those seasonal and breed-specific differences in the performance of bucks should help to improve the management of individual semen samples for use in artificial insemination programs.

  19. PWM Regulation of Grid-Tied PV System on the Base of Photovoltaic-Fed Diode-Clamped Inverters

    Directory of Open Access Journals (Sweden)

    Oleschuk V.I.

    2015-12-01

    Full Text Available Investigation of grid-tied photovoltaic system on the base of two diode-clamped inverters, controlled by specific algorithms of pulse-width modulation (PWM, has been done. This system includes two strings of photovoltaic panels feeding two diode-clamped inverters. The outputs of inverters are connected with the corresponding windings on the primary side of three-phase transformer, connected with a grid. In order to reduce phase voltage distortion and to increase efficiency of operation of the system, special scheme of control and modulation of inverters has been used, providing minimization of common-mode voltages and voltage waveforms symmetries under different operating conditions. Detailed simulation of processes in this photovoltaic-fed power conversion system has been executed. The results of simulations verify good performance of photovoltaic system regulated in accordance with specific strategy of control and modulation.

  20. A modified LLCL-filter with the reduced conducted EMI noise

    DEFF Research Database (Denmark)

    Wu, Weimin; Sun, Yunjie; Lin, Zhe

    2013-01-01

    For a transformerless grid-tied converter using Pulse Width Modulation (PWM), the harmonics of grid-injected current, the leakage current and the Electromagnetic Interference (EMI) noise are three important issues during design of the output filter. In this paper, the Common-Mode (CM...