WorldWideScience

Sample records for pvc sensor based

  1. Strontium PVC-membrane sensor based on 2-[(2-mercaptophenylimino)methyl]phenol

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali [Young Researchers Club, Quchan branch, Islamic Azad University, Quchan (Iran, Islamic Republic of)], E-mail: haszamani@yahoo.com; Ganjali, Mohammad Reza; Norouzi, Parviz [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Endocrine and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Adib, Mahdi [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of)

    2008-01-10

    The 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) was used as an excellent ionophore in the construction of a Sr{sup 2+} PVC-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 62% nitrobenzen (NB), 5.5% MPMP and 2.5% sodium tetraphenyl borate (NaTBP). This sensor demonstrates a good selectivity and sensitivity towards the strontium ion for many cations, including alkali, alkaline earth, transition and heavy metal ions. The sensor revealed a great enhancement in selectivity coefficients for strontium ions in comparison with the previously reported strontium sensors. The proposed sensor exhibits a Nernstian behavior (with a slope of 29.6 {+-} 0.3 mV per decade) for the concentration range of (1.0 x 10{sup -6}-1.0 x 10{sup -1} M) with a detection limit of 5.5 x 10{sup -7} M (48.2 ng/mL). It illustrates a relatively fast response time in the whole concentration range (< 10 s) and it can be used for at least 10 weeks in a pH range of 2.8-9.6. The developed sensor was successfully used as an indicator electrode in the Sr(II) titration with EDTA and the Sr{sup 2+} ion recovery from binary mixtures.

  2. A PVC/polypyrrole sensor designed for beef taste detection using electrochemical methods and sensory evaluation.

    Science.gov (United States)

    Zhu, Lingtao; Wang, Xiaodan; Han, Yunxiu; Cai, Yingming; Jin, Jiahui; Wang, Hongmei; Xu, Liping; Wu, Ruijia

    2018-03-01

    An electrochemical sensor for detection of beef taste was designed in this study. This sensor was based on the structure of polyvinyl chloride/polypyrrole (PVC/PPy), which was polymerized onto the surface of a platinum (Pt) electrode to form a Pt-PPy-PVC film. Detecting by electrochemical methods, the sensor was well characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The sensor was applied to detect 10 rib-eye beef samples and the accuracy of the new sensor was validated by sensory evaluation and ion sensor detection. Several cluster analysis methods were used in the study to distinguish the beef samples. According to the obtained results, the designed sensor showed a high degree of association of electrochemical detection and sensory evaluation, which proved a fast and precise sensor for beef taste detection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. PVC-membrane potentiometric sensors based on a recently synthesized Schiff base for Fe(III ion

    Directory of Open Access Journals (Sweden)

    S. Yousef Ebrahimipur

    2012-12-01

    Full Text Available A potentiometric iron sensor based on the use 3-(2-diethylamino-ethylimino-1,3-dihydro-indol-2-one (DEDIO as an ionophore in poly(vinyl chloride (PVC matrix, is reported. The plasticized membrane sensor exhibits a Nernstian response for Fe(III ions over a wide concentration range (2.0 × 10-6 - 5.0 × 10-2 M with a super Nernstian slope of 26(plus or minus 1 mV per decade. It has a fast response time of less than 12 s and can be used for ten weeks without any considerable divergences in its potentials the electrode can be used in the pH range 4.5-8.0. The proposed sensor shows fairly good discriminating ability towards Fe(III ion in comparison with a large number of alkali, alkaline earth, transition and heavy metal ions. The sensor was used as indicator electrode in potentiometric titration of Fe(III ions vs. EDTA.DOI: http://dx.doi.org/10.4314/bcse.v26i1.7

  4. Construction of Tm3+-PVC membrane sensor based on 1-(2-thiazolylazo)-2-naphthol as sensing material

    International Nuclear Information System (INIS)

    Zamani, Hassan Ali; Nekoei, Mehdi; Mohammadhosseini, Majid; Ganjali, Mohammad Reza

    2010-01-01

    In this study, a new thulium(III) membrane sensor was constructed. The proposed membrane sensor was fabricated based on a membrane containing 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 65% benzyl acetate (BA) as solvent mediator, 3% 1-(2-thiazolylazo)-2-naphthol (TN) as ionophore, and 30% poly(vinyl chloride) (PVC). The proposed Tm 3+ electrode exhibits a Nernstian response of 19.5 ± 0.2 mV per decade of thulium concentration, and has a lower detection limit of 8.7 x 10 -7 mol L -1 . The linear range of the sensors was 1.0 x 10 -6 to 1.0 x 10 -2 mol L -1 . It works well in the pH range of 3.2-9.5. Moreover, the recommended selective sensor revealed a comparatively satisfactory selectivity regarding most of the alkali, alkaline earth, some transition and heavy metal ions. The membrane sensor was applied to the determination of fluoride ions in mouth wash samples.

  5. Neodymium(III PVC Membrane Electrodchemical Sensor Based on N-benzoylethylidene-2-aminobenzylamine

    Directory of Open Access Journals (Sweden)

    Hassan Ali Zamani

    2012-01-01

    Full Text Available The N-benzoylethylidene-2-aminobenzylamine (BEA was used as a suitable ionophore in construction of neodymium ion selective electrode. The electrode with composition of 30% PVC, 58% solvent mediator (NB, 2% ionophore (BEA and 10% anionic additive (OA shows the best potentiometric response characteristics. The Nd3+ sensor exhibits a Nernstian slope of 21.2 ± 0.2 mV decade-1 over the concentration range of 1.0 × 10-6 to 1.0 × 10-2 mol L-1, and a detection limit of 6.3 × 10-7 mol L-1 of Nd3+ ions. The potentiometric response of the sensor is independent of the solution pH in the range of 2.4–8.5. It has a very short response time, in the whole concentration range (~7 s, and can be used for at least eight weeks. The proposed sensor revealed high selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions, including members of the lanthanide family other than Nd3+. The Nd3+ sensor was successfully applied as an indicator electrode in the potentiometric titration of Nd3+ ions with EDTA. The electrode was also employed for the determination of the fluoride ion in two mouth wash preparations.

  6. Construction of Tm{sup 3+}-PVC membrane sensor based on 1-(2-thiazolylazo)-2-naphthol as sensing material

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Quchan Branch, Islamic Azad University, Quchan (Iran, Islamic Republic of); Nekoei, Mehdi; Mohammadhosseini, Majid [Department of Chemistry, Faculty of Basic Sciences, Shahrood Branch, Islamic Azad University, Shahrood (Iran, Islamic Republic of); Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Medical Nanotechnology Research Centre, Tehran University of Medical Sciences, Tehran, P.O. Box, 14155-6451 (Iran, Islamic Republic of)

    2010-04-06

    In this study, a new thulium(III) membrane sensor was constructed. The proposed membrane sensor was fabricated based on a membrane containing 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 65% benzyl acetate (BA) as solvent mediator, 3% 1-(2-thiazolylazo)-2-naphthol (TN) as ionophore, and 30% poly(vinyl chloride) (PVC). The proposed Tm{sup 3+} electrode exhibits a Nernstian response of 19.5 {+-} 0.2 mV per decade of thulium concentration, and has a lower detection limit of 8.7 x 10{sup -7} mol L{sup -1}. The linear range of the sensors was 1.0 x 10{sup -6} to 1.0 x 10{sup -2} mol L{sup -1}. It works well in the pH range of 3.2-9.5. Moreover, the recommended selective sensor revealed a comparatively satisfactory selectivity regarding most of the alkali, alkaline earth, some transition and heavy metal ions. The membrane sensor was applied to the determination of fluoride ions in mouth wash samples.

  7. Fabrication of a PVC membrane samarium(III) sensor based on N,N′,N″-tris(4-pyridyl)trimesic amide as a selectophore

    International Nuclear Information System (INIS)

    Zamani, Hassan Ali; Naghavi-Reyabbi, Fatemeh; Faridbod, Farnoush; Mohammadhosseini, Majid; Ganjali, Mohammad Reza; Tadjarodi, Azadeh; Rad, Maryam

    2013-01-01

    A new ion-selective electrode for Sm 3+ ion is described based on the incorporation of N,N′,N″-tris(4-pyridyl)trimesic amide (TPTA) in a poly(vinylchloride) (PVC) matrix. The membrane sensor comprises nitrobenzene (NB) as a plasticizer, and oleic acid (OA) as an anionic additive. The sensor with the optimized composition shows a Nernstian potential response of 19.8 ± 0.5 mV decade −1 over a wide concentration range of 1.0 × 10 −2 and 1 × 10 −6 mol L −1 , with a lower detection limit of 4.7 × 10 −7 mol L −1 and satisfactor applicable pH range of 3.6–9.2. Having a short response time of less than 10 s and a very good selectivity towards the Sm 3+ over a wide variety of interfering cations (e.g. alkali, alkaline earth, transition and heavy metal ions) the sensor seemed to be a promising analytical tool for determination of the Sm 3+ . Hence, it was used as an indicator electrode in the potentiometric titration of samarium ion with EDTA. It was also applied to the direct samarium recovery in binary mixtures. - Highlights: ► A new Sm 3+ -PVC membrane sensor is introduced for determination of Sm 3+ ions in the solutions. ► N,N′,N″-tris(4-pyridyl)trimesic amide was used as a suitable selectophore for samarium sensor. ► Detection limit of the sensor is 4.7 × 10 −7 mol L −1 with a short response time of less than 10 s.

  8. PVC Based Selective Sensors for Ni2+ Ions Using Carboxylated and Methylated Porphine

    Directory of Open Access Journals (Sweden)

    J. M. Bhatnagar

    2003-09-01

    Full Text Available Poly vinylchloride (PVC based membranes of 4,4',4'',4'''-21H,23H-porphine–5,10,15,20 –tetrayl tetrakis (benzoic acid (TBAP and 2,3,7,8,12,13,17,18-octamethyl - 21H, 23H-porphine (OMP were prepared using dibutyl phthalate (DBP, dioctylphthalate (DOP, dibutyl(butylphosphonate (DBBP and 1-chloronaphthalene (CN as plastcizing solvent mediators and sodium tetraphenylborate (NaTPB as an anion excluder for Ni2+ selective sensors. TBAP based membrane exhibits linearity over a wide concentration range 2.0x10-6–1.0x10-1M (0.12 – 5.8x103ppm with a slope of 29.6 mV/decade of activity while OMP based membrane showed linear potential response in the concentration range 1.0x10-5 –1.0x 10-1M (0.60 – 5.8x103ppm with a Nernstian slope of 29.0 mV/decade of activity. The electrode assembly works between pH 2.0 – 7.0, exhibits a fast response time of 10-15s and performed satisfactorily over a period of six months with good reproducibility. Excellent selectivity of the order of 10-3 over a number of cations and quantitative determination of Ni2+ in effluents discharged from electroplating industry demonstrates the utility of the proposed sensor. The electrode assembly was also used as an indicator electrode in the potentiometric titration of Ni2+ with EDTA.

  9. Development of pvc membrane based potentiometric pH sensor using amine type neutral carrier

    International Nuclear Information System (INIS)

    Khan, M.F.

    1999-01-01

    The glass membrane-based pH-electrode has proved its utility over decades. However some limitations are associated with these type of sensors. It can not be used for measuring pH of hydrofluoric acid solution and is difficult to miniaturize for biological applications due to its high resistance and fragility. In the present investigation modified PVC-membranes have been cast by incorporating lipophilic salt tetrabutyl ammonium tetraphenylborate and sodium tetraphenylborate along with electro active compound tri-n-octylamine as neutral carrier. The performance comparison of fabricated pH-sensitive membrane electrode has been carried out regarding their Nernstian slope and life time. The performance comparison of the membrane electrodes fabricated from laboratory grade tri-n-octylamine and those prepared from highly purified ionophore was also carried out. The slopes of the modified membrane electrodes based on pure ionophore were 59 mV/decade H/sup +/ ions and commercial ionophore 54 mV/decade H/sup +/ ions. The linear range was from pH 5-11. In the range of pH 6-10 response was excellent. The measurement of selectivity coefficients for the probable, interfering ions (anions and cations) were also carried out. (author)

  10. Comparative studies of neodymium (III)-selective PVC membrane sensors

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Vinod K., E-mail: vinodfcy@iitr.ernet.in [Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247 667 (India); Goyal, Rajendra N.; Sharma, Ram A. [Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247 667 (India)

    2009-08-04

    Sensors based on two neutral ionophores, N,N'-bis((1H-pyrrol-2-yl)methylene)cyclohexane-1,2-diamine (L{sub 1}) and 3,3'-(cyclohexane-1,2-diylbis(azan-1-yl-1-ylidene) bis(methan-1-yl-1-ylidene)bis(5-hydroxymethyl)pyridine-2-ol) (L{sub 2}) are described for quantification of neodymium (III). Effect of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dibutyl butylphosphonate (DBBP), tri-n-butyl phosphates (TBP), dioctylpthalate (DOP) and chloronapthalen (CN) and anion excluder, sodiumtetraphenylborate (NaTPB) has been studied. The membrane composition of PVC:o-NPOE:ionophore (L{sub 1}):NaTPB (w/w; mg) of 150:300:5:5 exhibited best performance. The sensor with ionophore (L{sub 1}) exhibits significantly enhanced selectivity towards neodymium (III) in the concentration range 5.0 x 10{sup -7} to 1.0 x 10{sup -2} M with a detection limit of 1.0 x 10{sup -7} M and a Nernstian compliance (19.8 {+-} 0.3 mV decade{sup -1} of activity) within pH range 4.0-8.0. The response time of sensor was found as 10 s. The influence of the membrane composition and possible interfering ions has also been investigated on the response properties of the electrode. The fast and stable response, good reproducibility and long-term stability of the sensor are observed. The sensor has been found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for neodymium. The proposed electrode shows fairly good discrimination of neodymium (III) from other cations. The application of prepared sensor has been demonstrated in the determination of neodymium (III) in spiked water samples.

  11. PVC membrane based potentiometric sensor for uranyl ion using thenoyl trifluoro acetone as ionophore

    International Nuclear Information System (INIS)

    Nanda, D.; Chouhan, H.P.S.; Maiti, B.

    2004-01-01

    Uranyl ion selective electrode based on thenoyl trifluoro acetone (TTA) incorporated into a polyvinyl chloride (PVC) membrane has been developed where dibutyl phthalate and sodium tetraphenyl borate have been used as plasticizer and anion excluder respectively. The PVC membrane containing the active ionophore, TTA, and the other ingredients has been directly cast a graphite electrode. The electrode shows near Nernstian response to UO 2 2+ in the concentration range of 10 -1 to 10 -6 mol. L -1 an average slope of 30 mV/decade. Alkali and alkaline earth ions do not interfere with the determination of uranyl ion. Interference of transition metal ions and Th (IV) is eliminated using EDTA. (author)

  12. Construction of Tb3+ PVC-MembraneElectrode Based on N,N’-Bis(pyrrolylmethylene-2-aminobenzylamine

    Directory of Open Access Journals (Sweden)

    Hassan Ali Zamani

    2011-01-01

    Full Text Available In this work, we report as new Tb3+-PVC membrane sensor based on N,N’-bis(pyrrolylmethylene- 2-aminobenzylamine (PMA as a suitable ion carrier. Poly vinylchloride (PVC-based membrane composed of PMA with oleic acid (OA as anionic additives and acetophenone (AP as plasticizing solvent mediators. The Tb3+ sensor exhibits a Nernstian slope of 19.7±0.4 mV per decade over the concentration range of 1.0×10-5 to 1.0×10-2 M and a detection limit of 4.6×10-6 M of Tb3+ ions. The potentiometric response of the sensor is independent of the solution pH in the range of 2.9–8.1. It has a very short response time, in the whole concentration range (∼5 s. The recommended sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Tb(III ions with EDTA. The electrode was also employed for the determination of the fluoride ion in two mouth wash preparations and the determination of Tb3+ ions concentration in mixtures of three different ions.

  13. Fabrication of a PVC membrane samarium(III) sensor based on N,N Prime ,N Double-Prime -tris(4-pyridyl)trimesic amide as a selectophore

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of); Naghavi-Reyabbi, Fatemeh [Resident of General Surgery, Endoscopic and Minimaly Invasive Surgery Research Center, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad (Iran, Islamic Republic of); Faridbod, Farnoush [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Mohammadhosseini, Majid [Department of Chemistry, Faculty of Basic Sciences, Shahrood Branch, Islamic Azad University, Shahrood (Iran, Islamic Republic of); Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Tadjarodi, Azadeh; Rad, Maryam [Department of Chemistry, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2013-03-01

    A new ion-selective electrode for Sm{sup 3+} ion is described based on the incorporation of N,N Prime ,N Double-Prime -tris(4-pyridyl)trimesic amide (TPTA) in a poly(vinylchloride) (PVC) matrix. The membrane sensor comprises nitrobenzene (NB) as a plasticizer, and oleic acid (OA) as an anionic additive. The sensor with the optimized composition shows a Nernstian potential response of 19.8 {+-} 0.5 mV decade{sup -1} over a wide concentration range of 1.0 Multiplication-Sign 10{sup -2} and 1 Multiplication-Sign 10{sup -6} mol L{sup -1}, with a lower detection limit of 4.7 Multiplication-Sign 10{sup -7} mol L{sup -1} and satisfactor applicable pH range of 3.6-9.2. Having a short response time of less than 10 s and a very good selectivity towards the Sm{sup 3+} over a wide variety of interfering cations (e.g. alkali, alkaline earth, transition and heavy metal ions) the sensor seemed to be a promising analytical tool for determination of the Sm{sup 3+}. Hence, it was used as an indicator electrode in the potentiometric titration of samarium ion with EDTA. It was also applied to the direct samarium recovery in binary mixtures. - Highlights: Black-Right-Pointing-Pointer A new Sm{sup 3+}-PVC membrane sensor is introduced for determination of Sm{sup 3+} ions in the solutions. Black-Right-Pointing-Pointer N,N Prime ,N Double-Prime -tris(4-pyridyl)trimesic amide was used as a suitable selectophore for samarium sensor. Black-Right-Pointing-Pointer Detection limit of the sensor is 4.7 Multiplication-Sign 10{sup -7} mol L{sup -1} with a short response time of less than 10 s.

  14. Europium (III) PVC membrane sensor based on N-pyridine-2-carboxamido-8-aminoquinoline as a sensing material

    International Nuclear Information System (INIS)

    Zamani, Hassan Ali; Kamjoo, Rahman; Mohammadhosseini, Majid; Zaferoni, Mojdeh; Rafati, Zynab; Ganjali, Mohammad Reza; Faridbod, Farnoush; Meghdadi, Soraia

    2012-01-01

    Conductometric study in acetonitrile solution shows the selectivity of PCQ toward europium ion. Therefore, a new europium PVC membrane electrode was prepared based on N-pyridine-2-carboxamido-8-aminoquinoline (PCQ) as an ion carrier. The electrode has a wide concentration range from 1.0 × 10 −2 and 1.0 × 10 −6 mol L −1 , Nernstian slope of 19.8 ± 0.3 mV per decade and a detection limit of 6.4 × 10 −7 mol L −1 . The potentiometric response is pH independent in the range of 2.4–7.4. The proposed sensor has a relatively fast response time less than 10 s and it can be used for at least 2 months without any considerable divergence in its potentials. The proposed electrode revealed good selectivity toward europium ion in comparison with variety of other metal ions. The practical utility of the electrodes has been demonstrated by their use as indicator electrodes in the potentiometric titration of Eu 3+ ions with EDTA and for determination of Eu 3+ ion concentration in mixtures of two and three different ions. - Highlights: ► A new ion carrier is introduced to preparation of a selective sensor for Eu 3+ ions. ► This technique is very simple and it's not necessary to use sophisticated equipment. ► The novelty of this work is the high affinity of the ionophore toward the Eu 3+ ions. ► The sensor is superior to the formerly reported Eu 3+ sensors in terms of selectivity.

  15. Renewable urea sensor based on a self-assembled polyelectrolyte layer.

    Science.gov (United States)

    Wu, Zhaoyang; Guan, Lirui; Shen, Guoli; Yu, Ruqin

    2002-03-01

    A renewable urea sensor based on a carboxylic poly(vinyl chloride) (PVC-COOH) matrix pH-sensitive membrane has been proposed, in which a positively charged polyelectrolyte layer is first constructed by using a self-assembly technique on the surface of a PVC-COOH membrane, and urease, with negative charges, is then immobilized through electrostatic adsorption onto the PVC-COOH membrane, by controlling the pH of the urease solution below its isoelectric point. The response characteristics of the PVC-COOH pH-sensitive membrane and the effects of experimental conditions have been investigated in detail. Compared with conventional covalent immobilization, the urea sensor made with this self-assembly immobilization shows significant advantage in terms of sensitivity and ease of regeneration. The potential responses of the urea sensor with self-assembly immobilization increase with the urea concentration over the concentration range 10(-5) - 10(-1) mol l(-1), and the detection limit is 0.028 mmol(-1). Moreover, this type of urea sensor can be repeatedly regenerated by using a simple washing treatment with 0.01 mol l(-1) NaOH (containing 0.5 mol l(-1) NaCl) and 0.01 mol l(-1) HCl. The urease layers and the polyelectrolyte layers on the PVC-COOH membrane are removed, the potential response of the sensor to urea solutions of different concentrations returns nearly to zero, and another assembly cycle of urease and polyelectrolyte can then be carried out.

  16. Europium (III) PVC membrane sensor based on N-pyridine-2-carboxamido-8-aminoquinoline as a sensing material

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Quchan branch, Islamic Azad University, Quchan (Iran, Islamic Republic of); Kamjoo, Rahman [Department of Applied Chemistry, Quchan branch, Islamic Azad University, Quchan (Iran, Islamic Republic of); Mohammadhosseini, Majid [Department of Chemistry, Faculty of Basic Sciences, Shahrood Branch, Islamic Azad University, Shahrood (Iran, Islamic Republic of); Zaferoni, Mojdeh; Rafati, Zynab [Department of Applied Chemistry, Quchan branch, Islamic Azad University, Quchan (Iran, Islamic Republic of); Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Faridbod, Farnoush [Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Meghdadi, Soraia [Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2012-04-01

    Conductometric study in acetonitrile solution shows the selectivity of PCQ toward europium ion. Therefore, a new europium PVC membrane electrode was prepared based on N-pyridine-2-carboxamido-8-aminoquinoline (PCQ) as an ion carrier. The electrode has a wide concentration range from 1.0 Multiplication-Sign 10{sup -2} and 1.0 Multiplication-Sign 10{sup -6} mol L{sup -1}, Nernstian slope of 19.8 {+-} 0.3 mV per decade and a detection limit of 6.4 Multiplication-Sign 10{sup -7} mol L{sup -1}. The potentiometric response is pH independent in the range of 2.4-7.4. The proposed sensor has a relatively fast response time less than 10 s and it can be used for at least 2 months without any considerable divergence in its potentials. The proposed electrode revealed good selectivity toward europium ion in comparison with variety of other metal ions. The practical utility of the electrodes has been demonstrated by their use as indicator electrodes in the potentiometric titration of Eu{sup 3+} ions with EDTA and for determination of Eu{sup 3+} ion concentration in mixtures of two and three different ions. - Highlights: Black-Right-Pointing-Pointer A new ion carrier is introduced to preparation of a selective sensor for Eu{sup 3+} ions. Black-Right-Pointing-Pointer This technique is very simple and it's not necessary to use sophisticated equipment. Black-Right-Pointing-Pointer The novelty of this work is the high affinity of the ionophore toward the Eu{sup 3+} ions. Black-Right-Pointing-Pointer The sensor is superior to the formerly reported Eu{sup 3+} sensors in terms of selectivity.

  17. Web Based ATM PVC Management

    NARCIS (Netherlands)

    van der Waaij, B.D.; Sprenkels, Ron; van Beijnum, Bernhard J.F.; Pras, Aiko

    1998-01-01

    This paper discusses the design of a public domain web based ATM PVC Management tool for the Dutch SURFnet research ATM network. The aim of this tool is to assists in the creation and deletion of PVCs through local and remote ATM network domains. The tool includes security mechanisms to restrict the

  18. Zinc(II PVC-based membrane sensor based on 5,6-benzo-4,7,13,16,21,24- hexaoxa-1,10-diazabicyclo[8,8,8]hexacos-5-ene

    Directory of Open Access Journals (Sweden)

    Zamani Hassan Ali

    2006-01-01

    Full Text Available The 5,6-benzo-4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo[8,8,8]hexacos-5-ene (BHDE was used as an excellent ionophore in construction of a Zn(II PVC-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride, 64.5% nitrobenzen (NB, 2.5% BHDE and 3% sodium tetraphenylborate (NaTPB. This sensor shows very good selectivity and sensitivity towards zinc ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The sensor revealed a great enhancement in selectivity coefficients for zinc ions, in comparison to the previously reported zinc sensors. The proposed sensor exhibits a Nernstian behavior (with slope of 29.1 ? 0.4 mV per decade over a wide concentration range (1.0 10-6-1.0 10-1 mol L-1 with a detection limit of 6.3 x10-7 mol L-1 (41.2 ng mL-1. It shows relatively fast response time, in the whole concentration range (< 10s, and can be used for at least 10 weeks in a pH range of 2.8-7.3. The proposed sensor was successfully used in direct determination of zinc ions in wastewater of industrial zinc electroplating companies, and also as an indicator electrode in titration with EDTA.

  19. PET and PVC Separation with Hyperspectral Imagery

    Science.gov (United States)

    Moroni, Monica; Mei, Alessandro; Leonardi, Alessandra; Lupo, Emanuela; La Marca, Floriana

    2015-01-01

    Traditional plants for plastic separation in homogeneous products employ material physical properties (for instance density). Due to the small intervals of variability of different polymer properties, the output quality may not be adequate. Sensing technologies based on hyperspectral imaging have been introduced in order to classify materials and to increase the quality of recycled products, which have to comply with specific standards determined by industrial applications. This paper presents the results of the characterization of two different plastic polymers—polyethylene terephthalate (PET) and polyvinyl chloride (PVC)—in different phases of their life cycle (primary raw materials, urban and urban-assimilated waste and secondary raw materials) to show the contribution of hyperspectral sensors in the field of material recycling. This is accomplished via near-infrared (900–1700 nm) reflectance spectra extracted from hyperspectral images acquired with a two-linear-spectrometer apparatus. Results have shown that a rapid and reliable identification of PET and PVC can be achieved by using a simple two near-infrared wavelength operator coupled to an analysis of reflectance spectra. This resulted in 100% classification accuracy. A sensor based on this identification method appears suitable and inexpensive to build and provides the necessary speed and performance required by the recycling industry. PMID:25609050

  20. PET and PVC separation with hyperspectral imagery.

    Science.gov (United States)

    Moroni, Monica; Mei, Alessandro; Leonardi, Alessandra; Lupo, Emanuela; Marca, Floriana La

    2015-01-20

    Traditional plants for plastic separation in homogeneous products employ material physical properties (for instance density). Due to the small intervals of variability of different polymer properties, the output quality may not be adequate. Sensing technologies based on hyperspectral imaging have been introduced in order to classify materials and to increase the quality of recycled products, which have to comply with specific standards determined by industrial applications. This paper presents the results of the characterization of two different plastic polymers--polyethylene terephthalate (PET) and polyvinyl chloride (PVC)--in different phases of their life cycle (primary raw materials, urban and urban-assimilated waste and secondary raw materials) to show the contribution of hyperspectral sensors in the field of material recycling. This is accomplished via near-infrared (900-1700 nm) reflectance spectra extracted from hyperspectral images acquired with a two-linear-spectrometer apparatus. Results have shown that a rapid and reliable identification of PET and PVC can be achieved by using a simple two near-infrared wavelength operator coupled to an analysis of reflectance spectra. This resulted in 100% classification accuracy. A sensor based on this identification method appears suitable and inexpensive to build and provides the necessary speed and performance required by the recycling industry.

  1. Polymeric membrane sensors based on Cd(II) Schiff base complexes for selective iodide determination in environmental and medicinal samples.

    Science.gov (United States)

    Singh, Ashok Kumar; Mehtab, Sameena

    2008-01-15

    The two cadmium chelates of schiff bases, N,N'-bis(salicylidene)-1,4-diaminobutane, (Cd-S(1)) and N,N'-bis(salicylidene)-3,4-diaminotoluene (Cd-S(2)), have been synthesized and explored as ionophores for preparing PVC-based membrane sensors selective to iodide(I) ion. Potentiometric investigations indicate high affinity of these receptors for iodide ion. Polyvinyl chloride (PVC)-based membranes of Cd-S(1) and Cd-S(2) using as hexadecyltrimethylammonium bromide (HTAB) cation discriminator and o-nitrophenyloctyl ether (o-NPOE), dibutylphthalate (DBP), acetophenone (AP) and tributylphosphate (TBP) as plasticizing solvent mediators were prepared and investigated as iodide-selective sensors. The best performance was shown by the membrane of composition (w/w) of (Cd-S(1)) (7%):PVC (31%):DBP (60%):HTAB (2%). The sensor works well over a wide concentration range 5.3x10(-7) to 1.0x10(-2)M with Nernstian compliance (59.2mVdecade(-1) of activity) within pH range 2.5-9.0 with a response time of 11s and showed good selectivity for iodide ion over a number of anions. The sensor exhibits adequate life (3 months) with good reproducibility (S.D.+/-0.24mV) and could be used successfully for the determination of iodide content in environmental water samples and mouth wash samples.

  2. Highly Sensitive Sensors Based on Metal-Oxide Nanocolumns for Fire Detection

    Directory of Open Access Journals (Sweden)

    Kwangjae Lee

    2017-02-01

    Full Text Available A fire detector is the most important component in a fire alarm system. Herein, we present the feasibility of a highly sensitive and rapid response gas sensor based on metal oxides as a high performance fire detector. The glancing angle deposition (GLAD technique is used to make the highly porous structure such as nanocolumns (NCs of various metal oxides for enhancing the gas-sensing performance. To measure the fire detection, the interface circuitry for our sensors (NiO, SnO2, WO3 and In2O3 NCs is designed. When all the sensors with various metal-oxide NCs are exposed to fire environment, they entirely react with the target gases emitted from Poly(vinyl chlorides (PVC decomposed at high temperature. Before the emission of smoke from the PVC (a hot-plate temperature of 200 °C, the resistances of the metal-oxide NCs are abruptly changed and SnO2 NCs show the highest response of 2.1. However, a commercial smoke detector did not inform any warning. Interestingly, although the NiO NCs are a p-type semiconductor, they show the highest response of 577.1 after the emission of smoke from the PVC (a hot-plate temperature of 350 °C. The response time of SnO2 NCs is much faster than that of a commercial smoke detector at the hot-plate temperature of 350 °C. In addition, we investigated the selectivity of our sensors by analyzing the responses of all sensors. Our results show the high potential of a gas sensor based on metal-oxide NCs for early fire detection.

  3. Photostabilizing Efficiency of PVC in the Presence of Schiff Bases as Photostabilizers

    Directory of Open Access Journals (Sweden)

    Emad Yousif

    2015-11-01

    Full Text Available The photostabilization of polyvinyl chloride (PVC films by Schiff bases was investigated. Polyvinyl chloride films containing 0.5 wt % Schiff bases were produced using the same casting method as that used for additive-free PVC films from tetrahydrofuran (THF solvent. The photostabilization activities of these compounds were determined by monitoring the carbonyl, polyene and hydroxyl indices with irradiation time. The changes in viscosity average molecular weight of PVC with irradiation time were also monitored using THF as a solvent. The quantum yield of chain scission (Φcs for the studied complexes in PVC was estimated to range between 4.72 and 8.99 × 10−8. According to the experimental results, several mechanisms were suggested, depending on the structure of the additive. Ultra violet (UV absorption, peroxide decomposition and radical scavenging were suggested as the photostabilizing mechanisms.

  4. Comparative studies of praseodymium(III) selective sensors based on newly synthesized Schiff's bases

    International Nuclear Information System (INIS)

    Gupta, Vinod K.; Goyal, Rajendra N.; Pal, Manoj K.; Sharma, Ram A.

    2009-01-01

    Praseodymium ion selective polyvinyl chloride (PVC) membrane sensors, based on two new Schiff's bases 1,3-diphenylpropane-1,3-diylidenebis(azan-1-ylidene)diphenol (M 1 ) and N,N'-bis(pyridoxylideneiminato) ethylene (M 2 ) have been developed and studied. The sensor having membrane composition of PVC: o-NPOE: ionophore (M 1 ): NaTPB (w/w; mg) of 150: 300: 8: 5 showed best performances in comparison to M 2 based membranes. The sensor based on (M 1 ) exhibits the working concentration range 1.0 x 10 -8 to 1.0 x 10 -2 M with a detection limit of 5.0 x 10 -9 M and a Nernstian slope 20.0 ± 0.3 mV decade -1 of activity. It exhibited a quick response time as <8 s and its potential responses were pH independent across the range of 3.5-8.5.The influence of the membrane composition and possible interfering ions have also been investigated on the response properties of the electrode. The sensor has been found to work satisfactorily in partially non-aqueous media up to 15% (v/v) content of methanol, ethanol or acetonitrile and could be used for a period of 3 months. The selectivity coefficients determined by using fixed interference method (FIM) indicate high selectivity for praseodymium(III) ions over wide variety of other cations. To asses its analytical applicability the prepared sensor was successfully applied for determination of praseodymium(III) in spiked water samples.

  5. Immobilization of tris(2 pyridyl methylamine in a PVC-Membrane Sensor and Characterization of the Membrane Properties

    Directory of Open Access Journals (Sweden)

    Rezayi Majid

    2012-05-01

    Full Text Available Abstract Background Due to the increasing industrial use of titanium compounds, its determination is the subject of considerable efforts. The ionophore or membrane active recognition is the most important component of any polymeric membrane sensor. The sensor’s response depends on the ionophore and bonding between the ionophore and the target ion. Ionophores with molecule-sized dimensions containing cavities or semi-cavities can surround the target ion. The bond between the ionophore and target ion gives different selectivity and sensitivity toward the other ions. Therefore, ionophores with different binding strengths can be used in the sensor. Results In the present work, poly (vinyl chloride (PVC based membrane incorporating tris (2 pyridyl methylamine (tpm as an ionophore has been prepared and explored as a titanium(III selective sensor. Conclusions The strengths of the ion–ionophore (Ti(OH2+-tpm interactions and the role of ionophore on membrane were tested by various techniques such as elemental analysis, UV–vis, Fourier transform infrared (FTIR spectroscopy, scanning electron microscopy (SEM, and powder X-ray diffraction (XRD. All data approved the successful incorporation of organic group via covalent bond.

  6. Application of N-Quinoline-2-carboxamido-8-aminoquinoline in Fabrication of a Ho(III-PVC Membrane Sensor

    Directory of Open Access Journals (Sweden)

    Hassan Ali Zamani

    2011-01-01

    Full Text Available The N-quinoline-2-carboxamido-8-aminoquinoline (QCA was used as a suitable ion carrier in the construction of a Ho(III PVC-based membrane sensor. This sensor demonstrated good selectivity and sensitivity towards the holmium ion for a broad variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The proposed electrode exhibits a linear dynamic range between 1.0×10-6 and 1.0×10-2 M, with a near Nernstian slope of 20.4±0.3 mV per decade and a detection limit of 4.2×10-7 M. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride, 56% nitrobenzene, 2% sodium tetraphenyl borate, 10% oleic acid and 2% QCA. The potentiometric response of the constructed electrode is pH independent in the range of 2.4-7.4. The sensor possesses the advantages of short conditioning time, fast response time (∼ 5 s and especially, good selectivity towards transition and heavy metal and some mono, di and trivalent cations. The Ho3+ sensor was successfully applied as an indicator electrode in the potentiometric titration of Ho(III ions with EDTA. The electrode was also used for the determination of Ho3+ ions in mixtures of different ions and the determination of the fluoride ion in mouth wash solutions.

  7. Cation Recognition: Novel Potentiometric PVC-Membrane Sensor based on Meso-octamethylcalix[4]pyrrole for the Determination of Trace Amounts of Titanium (III) Ions

    International Nuclear Information System (INIS)

    Saeid Ahmadzadeh; Anuar Kassim Majid Rezayi

    2011-01-01

    The present work deals with developing a novel high selective membrane electrode based on meso-octamethylcalix[4]pyrrole for accurate determination of trace amount of titanium (III) ions in real sample solutions. The amounts of ionophore (4 mg), PVC (33 mg), dioctyl phthalate (DOP) as plasticizer (62.8 mg) and sodium tetrakis [3,5-bis (trifluoromethyl) phenyl] borate (NaTFPB) as an ionic additive (0.2 mg) were optimized in the preparation of the membrane. The electrode exhibited a linear response with a near Nernstian slope of 29.49±0.16 (mV per decade of activity) over the pH range from 1 to 3 with a satisfactory concentration range of 1.0 x 10 -6 to 1.0 x x10 -2 M. The developed sensor exhibited good reproducibility over a period of about 3 months with a fast response time of 15 seconds. (author)

  8. The viability of PVC/Al blister reuse and PVC property studies after ionizing radiation processing

    International Nuclear Information System (INIS)

    Castro, Alex Terela Pinheiro de

    2008-01-01

    The objective of this research was to separate, by means of a process of dissolution, the PVC and the aluminum that compose blister packs, generally used for pharmaceutical pills. We also studied the effect of the ionizing radiation on the PVC, and, finally, the mechanical recycling of the separated PVC, by a process of extrusion. The material we used in this work is the surplus of the pharmaceutical industry, i.e., packs with defects or burrs. We ground the material to facilitate the handling and the homogenization of the system. After that, we chose two bases for the dissolution of the aluminum: the sodium hydroxide and the potassium hydroxide. We used a system with two concentrations (1 and 2M) for each base, and for every solution we had also an agitated and a non-agitated process. From this method resulted eight experiments. After the dissolution, the samples of the material were submitted to ionizing radiation with doses of 50, 100, 150 and 200 kGy in the Dynamitron II electron accelerator of the CTR-IPEN/CNEN-SP. In the following, these samples were submitted to traction resistance tests to analyze which modifications the irradiation caused. The last step of the research was the recycling of the PVC separated from the Aluminum. We made the recycling in industrial equipment, a PVC tube extruder. The material was combined with lubricants, heat stabilizers and pigment in an intensive mixer and processed into the form of rigid PVC electrical conduits. After the eight experiments, the system with potassium hydroxide base, concentration of 2M and agitation presented the best relation between time of dissolution and characteristics of the resulting material, without degradation of the PVC. In the irradiated samples, the color of the material changed as well as its extension that was as larger as the dose of irradiation they received, indicating the dissociation of the PVC molecules. The extrusion of the PVC was successfully realized: about 200 kg (440 pounds) of

  9. Electrospinning of PVC with natural rubber

    Science.gov (United States)

    Othman, Muhammad Hariz; Mohamed, Mahathir; Abdullah, Ibrahim

    2013-11-01

    Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber's mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.

  10. Electrospinning of PVC with natural rubber

    International Nuclear Information System (INIS)

    Othman, Muhammad Hariz; Abdullah, Ibrahim; Mohamed, Mahathir

    2013-01-01

    Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber’s mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber

  11. Electrospinning of PVC with natural rubber

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Muhammad Hariz; Abdullah, Ibrahim [Department of Chemistry, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Mohamed, Mahathir [Radiation Processing Technology Division (BTS), Malaysian Nuclear Agency, Bangi, 43000, Kajang (Malaysia)

    2013-11-27

    Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber’s mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.

  12. Electrodos de PVC/TTF-TCNQ modificados. Aplicación como sensores y biosensores electroquímicos

    OpenAIRE

    Sánchez-Obrero, Guadalupe

    2013-01-01

    En este trabajo de Tesis Doctoral, se estudia el desarrollo de nuevos electrodos, basados en la modificación del electrodo compósito PVC/TTF-TCNQ, mediante nanopartículas de oro. Se pretende que estos nuevos electrodos sean susceptibles de ser empleados como sensores y/o biosensores electroquímicos, para la detección de analitos de interés. De ellos, se han elegido para su determinación la glucosa, el paracetamol y los compuestos fenólicos presentes en los vinos. La Tesis Doctoral está es...

  13. D-FNN Based Modeling and BP Neural Network Decoupling Control of PVC Stripping Process

    Directory of Open Access Journals (Sweden)

    Shu-zhi Gao

    2014-01-01

    Full Text Available PVC stripping process is a kind of complicated industrial process with characteristics of highly nonlinear and time varying. Aiming at the problem of establishing the accurate mathematics model due to the multivariable coupling and big time delay, the dynamic fuzzy neural network (D-FNN is adopted to establish the PVC stripping process model based on the actual process operation datum. Then, the PVC stripping process is decoupled by the distributed neural network decoupling module to obtain two single-input-single-output (SISO subsystems (slurry flow to top tower temperature and steam flow to bottom tower temperature. Finally, the PID controller based on BP neural networks is used to control the decoupled PVC stripper system. Simulation results show the effectiveness of the proposed integrated intelligent control method.

  14. An Enhanced Soft Vibrotactile Actuator Based on ePVC Gel with Silicon Dioxide Nanoparticles.

    Science.gov (United States)

    Park, Won-Hyeong; Shin, Eun-Jae; Yun, Sungryul; Kim, Sang-Youn

    2018-01-01

    In this paper, we propose a soft vibrotactile actuator made by mixing silicon dioxide nanoparticles and plasticized PVC gel. The effect of the silicon dioxide nanoparticles in the plasticized PVC gel for the haptic performance is investigated in terms of electric, dielectric, and mechanical properties. Furthermore, eight soft vibrotactile actuators are prepared as a function of the content. Experiments are conducted to examine the haptic performance of the prepared eight soft vibrotactile actuators and to find the best weight ratio of the plasticized PVC gel to the nanoparticles. The experiments should show that the plasticized PVC gel with silicon dioxide nanoparticles improves the haptic performance of the plasticized PVC gel-based vibrotactile actuator, and the proposed vibrotactile actuator can create a variety of haptic sensations in a wide frequency range.

  15. The viability of PVC/Al blister reuse and PVC property studies after ionizing radiation processing; Viabilizacao do reaproveitamento dos 'blister' de PVC/Al e estudos das propriedades do PVC apos processamento por radiacao ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Alex Terela Pinheiro de

    2008-07-01

    The objective of this research was to separate, by means of a process of dissolution, the PVC and the aluminum that compose blister packs, generally used for pharmaceutical pills. We also studied the effect of the ionizing radiation on the PVC, and, finally, the mechanical recycling of the separated PVC, by a process of extrusion. The material we used in this work is the surplus of the pharmaceutical industry, i.e., packs with defects or burrs. We ground the material to facilitate the handling and the homogenization of the system. After that, we chose two bases for the dissolution of the aluminum: the sodium hydroxide and the potassium hydroxide. We used a system with two concentrations (1 and 2M) for each base, and for every solution we had also an agitated and a non-agitated process. From this method resulted eight experiments. After the dissolution, the samples of the material were submitted to ionizing radiation with doses of 50, 100, 150 and 200 kGy in the Dynamitron II electron accelerator of the CTR-IPEN/CNEN-SP. In the following, these samples were submitted to traction resistance tests to analyze which modifications the irradiation caused. The last step of the research was the recycling of the PVC separated from the Aluminum. We made the recycling in industrial equipment, a PVC tube extruder. The material was combined with lubricants, heat stabilizers and pigment in an intensive mixer and processed into the form of rigid PVC electrical conduits. After the eight experiments, the system with potassium hydroxide base, concentration of 2M and agitation presented the best relation between time of dissolution and characteristics of the resulting material, without degradation of the PVC. In the irradiated samples, the color of the material changed as well as its extension that was as larger as the dose of irradiation they received, indicating the dissociation of the PVC molecules. The extrusion of the PVC was successfully realized: about 200 kg (440 pounds) of

  16. Near infrared reflectance spectroscopy for the fast identification of PVC-based films.

    Science.gov (United States)

    Laasonen, M; Rantanen, J; Harmia-Pulkkinen, T; Michiels, E; Hiltunen, R; Räsänen, M; Vuorela, H

    2001-07-01

    Near infrared (NIR) reflectance spectroscopy was used to develop a non-destructive and rapid qualitative method for the analysis of plastic films used by the pharmaceutical industry for blistering. Three types of films were investigated: 250 microm PVC [poly(vinyl chloride)] films, 250 microm PVC films coated with 40 g m(-2) of PVDC [poly(vinylidene dichloride)] and 250 microm PVC films coated with 5 g m(-2) of TE (Thermoelast) and 90 g m(-2) of PVDC. Three analyses were carried out using different pre-treatment options and a PLS (partial least squares) algorithm. Each analysis was aimed at identifying one type of film and rejecting all types of false sample (different thickness, colour or layer). True and false samples from four plastics manufacturers were included in the calibration sets in order to obtain robust methods that were suitable regardless of the supplier. Specificity was demonstrated by testing validation sets against the methods. The tests showed 0% of type I (false negative identification) and 1% of type II errors (false positive identification) for the PVC method, 13 and 3%, respectively, for the PVC-PVDC method and no error for the PVC-TE-PVDC method. Type II errors, mostly due to the slight sensitivity of the methods to film thickness, are easily corrected by simple thickness measurements. This study demonstrates that NIR spectroscopy is an excellent tool for the identification of PVC-based films. The three methods can be used by the pharmaceutical industry or plastics manufacturers for the quality control of films used in blister packaging.

  17. A novel highly sensitive and selective optical sensor based on a symmetric tetradentate Schiff-base embedded in PVC polymeric film for determination of Zn{sup 2+} ion in real samples

    Energy Technology Data Exchange (ETDEWEB)

    Abdel Aziz, Ayman A., E-mail: aymanaziz31@gmail.com [Chemistry Department, Faculty of Science, Ain Shams University, 11566 Cairo (Egypt); Chemistry Department, Faculty of Science, University of Tabuk, 71421, Tabuk (Saudi Arabia)

    2013-11-15

    A novel prepared Zn{sup 2+} ion PVC membrane sensor based on a novel Schiff base; N,N′bis(salicylaldehyde)2,3-diaminonaphthalene (SDN) for the determination of Zn{sup 2+} ion was described. The chemosensor was synthesized under microwave irradiation via condensation of 2,3-diaminonaphthalene and salicylaldehyde. Photoluminescence characteristics of the novel Schiff base ligand were investigated in different solvents including dicholoromethane (DCM), tetrahydrofuran (THF) and ethanol (EtOH). SDN was found to have higher emission intensity and Stoke’s shift value (Δλ{sub ST}) in EtOH solution. The sensor exhibited a specific fluorescent on response to Zn{sup 2+}. The response of the sensor is based on the fluorescence enhancement of SDN (LH{sub 2}) by Zn{sup 2+} ion as a result of formation the rigid structure L-Zn complex. The experiment results also show that the response behavior of SDN to Zn{sup 2+} is pH independent in the range of pH 6.0–8.0. At pH 7.0, the proposed sensor displays a calibration response for Zn{sup 2+} over a wide concentration range of 1.0×10{sup −9}–2.0×10{sup −3} mol L{sup −1} with a limit of detection (LOD) 8.1×10{sup −10} mol L{sup −1} (0.0529659 μg L{sup −1}). The sensor shows excellent selectivity toward Zn{sup 2+} with respect to common coexisting cations. The proposed fluorescence optode was successfully applied to detect Zn{sup 2+} in human hair samples, different brands of powdered milk and some pharmaceuticals. -- Highlights: • A novel Zn(II) chemosensor has been developed. • Wide linear concentration range of 1.0×10{sup −9}–2.0×10{sup −3} mol L{sup −1}. • Application for determination of Zn(II) in real samples.

  18. A Novel Sensor for Monitoring of Iron(III) Ions Based on Porphyrins

    Science.gov (United States)

    Vlascici, Dana; Fagadar-Cosma, Eugenia; Popa, Iuliana; Chiriac, Vlad; Gil-Agusti, Mayte

    2012-01-01

    Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10−7–1 × 10−1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples. PMID:22969395

  19. A novel sensor for monitoring of iron(III) ions based on porphyrins.

    Science.gov (United States)

    Vlascici, Dana; Fagadar-Cosma, Eugenia; Popa, Iuliana; Chiriac, Vlad; Gil-Agusti, Mayte

    2012-01-01

    Three A(3)B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10(-7)-1 × 10(-1) M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples.

  20. Enhanced Design of a Soft Thin-Film Vibrotactile Actuator Based on PVC Gel

    Directory of Open Access Journals (Sweden)

    Won-Hyeong Park

    2017-09-01

    Full Text Available We fabricated a soft thin-film vibrotactile actuator, which can be easily inserted into wearable devices, based on an electroactive PVC gel. One of the most important factors in fabricating a soft and thin vibrotactile actuator is to create vibrational force strong enough to stimulate human skin in a wide frequency range. To achieve this, we investigate the working principle of the PVC gel and suggest a new structure in which most of electric energy contributes to the deformation of the PVC gel. Due to this structure, the vibrational amplitude of the proposed PVC gel actuator could considerably increase (0.816 g (g = 9.8 m/s2 at resonant frequency. The vibrotactile amplitude is proportional to the amount of input voltage. It increased from 0.05 g up to 0.416 g with increasing applied voltages from 200 V to 1 kV at 1 Hz. The experimental results show that the proposed actuator can create a variety of haptic sensations.

  1. Carbon Nanotube-Based Ion Selective Sensors for Wearable Applications.

    Science.gov (United States)

    Roy, Soumyendu; David-Pur, Moshe; Hanein, Yael

    2017-10-11

    Wearable electronics offer new opportunities in a wide range of applications, especially sweat analysis using skin sensors. A fundamental challenge in these applications is the formation of sensitive and stable electrodes. In this article we report the development of a wearable sensor based on carbon nanotube (CNT) electrode arrays for sweat sensing. Solid-state ion selective electrodes (ISEs), sensitive to Na + ions, were prepared by drop coating plasticized poly(vinyl chloride) (PVC) doped with ionophore and ion exchanger on CNT electrodes. The ion selective membrane (ISM) filled the intertubular spaces of the highly porous CNT film and formed an attachment that was stronger than that achieved with flat Au, Pt, or carbon electrodes. Concentration of the ISM solution used influenced the attachment to the CNT film, the ISM surface morphology, and the overall performance of the sensor. Sensitivity of 56 ± 3 mV/decade to Na + ions was achieved. Optimized solid-state reference electrodes (REs), suitable for wearable applications, were prepared by coating CNT electrodes with colloidal dispersion of Ag/AgCl, agarose hydrogel with 0.5 M NaCl, and a passivation layer of PVC doped with NaCl. The CNT-based REs had low sensitivity (-1.7 ± 1.2 mV/decade) toward the NaCl solution and high repeatability and were superior to bare Ag/AgCl, metals, carbon, and CNT films, reported previously as REs. CNT-based ISEs were calibrated against CNT-based REs, and the short-term stability of the system was tested. We demonstrate that CNT-based devices implemented on a flexible support are a very attractive platform for future wearable technology devices.

  2. A reciclagem de PVC no Brasil Recycling of PVC Brazil

    Directory of Open Access Journals (Sweden)

    Ana Magda Piva

    1999-12-01

    Full Text Available Esta pesquisa discute as possibilidades práticas da reciclagem de PVC. Na reciclagem de polímeros, a do PVC representa uma importante parcela. PVC é um polímero que é usado em uma ampla faixa de produtos: filmes, fios, cabos, em compostos para uma variedade de formas. A reciclagem é uma técnica vantajosa, capaz de reproduzir as propriedades do polímero original, no polímero reciclado e isto em condições razoavelmente econômicas. A tecnologia brasileira, em relação a produtos reciclados, apresenta algumas diferenças da reciclagem tradicional. Métodos alternativos de reciclagens são necessários se os processos não desvalorizam os resultados finais.This research discuss the practical possibilities of recycling PVC. PVC, plays an important part in the recycleability of polymers; PVC is a polymer which is used in a very wide range of products -films, wire, cabes, in compounds for a variety of forms. Recycling is only worthwile, one is able to reproduce the original polymer properties in the polymer being recycled, and this under reasonable economics conditions. The brasilian technology that produces recycled products is a little different from the tradicional recycling. Therefore alternative methods to recycle are needed if recycling is not to devalue the end results.

  3. PVC-membrane potentiometric sensors based on a recently ...

    African Journals Online (AJOL)

    It has a fast response time of <12 s and can be used for ten weeks without any considerable divergences in its potentials .the electrode can be used in the pH range 4.5-8.0. The proposed sensor shows fairly good discriminating ability towards Fe(III) ion in comparison with a large number of alkali, alkaline earth, transition ...

  4. A Porphyrin Based Potentiometric Sensor for Zn2+ Determination

    Directory of Open Access Journals (Sweden)

    H. Lang

    2003-07-01

    Full Text Available PVC based membranes of disodium salt of porphyrin 3,7,12,17-tetramethyl-8, 13-divinyl 2,18-porphine dipropionic acid (I as ionophore with sodium tetra phenyl borate (NaTPB as anion excluder and dibutyl phthalate (DBP, dioctyl phthalate (DOP, dibutyl butyl phosphonate (DBBP, tris(2- ethyl hexylphosphate (TEP, tri-n-butylphosphate (TBP and 1- chloronaphthalene (CN as plasticizing solvent mediators were prepared and constructed for determination of Zn(II. The PVC based membrane of (I with DBBP as plasticizer and having anion excluder, NaTPB in the ratio PVC: I: NaTPB: DBBP (150: 10: 2: 200 gave the best results in terms of working concentration range (1.3×10-5-1.0 ×10-1M with a Nernstian slope (30.0 mV/decade of activity. The useful pH range of the sensor is 3.0 –7.4, beyond which a drift in potential was observed. The response time of the sensor is 10s and the lifetime was about 2 months during which it could be used without any measurable divergence. It had good stability and reproducibility. The membrane worked satisfactorily in non-aqueous medium up to 40% (v/v non-aqueous content. The selectivity coefficient values indicate that the electrode is highly selective for Zn2+ over a number of other cations except Na+ and Cd2+. Although Na+ and Cd2+ are likely to cause some interference, they would not interfere if present at the concentrations < 1 ×10-5 and < 5 ×10-5 M, respectively. The electrode has been used as an indicator electrode to determine the end point in the potentiometric titration of Zn2+ with EDTA.

  5. Immobilization of ionophore and surface characterization studies of the titanium(III) ion in a PVC-membrane sensor.

    Science.gov (United States)

    Rezayi, Majid; Heng, Lee Yook; Kassim, Anuar; Ahmadzadeh, Saeid; Abdollahi, Yadollah; Jahangirian, Hossein

    2012-01-01

    Novel ionophores comprising various hydroxide and amine structures were immobilized onto poly(vinyl chloride) (PVC) matrices, and these were examined to determine Ti(III) selectivity. To predict the selectivity of Ti(III), a PVC membrane was used to investigate the binding of Ti(III) to c-methylcalix[4]resorcinarene (CMCR). The study showed that the chelating ligand, CMCR, was coordinated selectively to Ti(III) at eight coordination sites involving the oxygen atoms at the interface of the membrane/solution. The membrane was prepared, based on CMCR as an ionophore, sodium tetrakis(4-fluorophenyl) borate (NaTFPB) as a lipophilic ionic additive, and dioctylphthalate (DOP) as a plasticizer. The immobilization of the ionophore and surface characterization studies revealed that the performance of CMCR-immobilized PVC was equivalent to that of mobile ionophores in supported liquid membranes (SLMs). The strengths of the ion-ionophore (CMCR-Ti(OH)(OH(2))(5) (2+)) interactions and the role of ionophores on membranes were studied via UV-Vis, Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and and X-ray diffraction (XRD).

  6. PVC gel soft actuator-based wearable assist wear for hip joint support during walking

    Science.gov (United States)

    Li, Yi; Hashimoto, Minoru

    2017-12-01

    Plasticized polyvinyl chloride (PVC) gel and mesh electrode-based soft actuators have considerable potential to provide new types of artificial muscle, exhibiting similar responsiveness to biological muscle in air, >10% deformation, >90 kPa output stress, variable stiffness, long cycle life (>5 million cycles), and low power consumption. We have designed and fabricated a prototype of walking assist wear using the PVC gel actuator in previous study. The system has several advantages compared with traditional motor-based exoskeletons, including lower weight and power consumption, and no requirement for rigid external structures that constrain the wearer’s joints. In this study, we designed and established a control and power system to making the whole system portable and wearable outdoors. And we designed two control strategies based on the characteristics of the assist wear and the biological kinematics. In a preliminary experimental evaluation, a hemiparetic stroke patient performed a 10 m to-and-fro straight line walking task with and without assist wear on the affected side. We found that the assist wear enabled natural movement, increasing step length and decreasing muscular activity during straight line walking. We demonstrated that the assistance effect could be adjusted by controlling the on-off time of the PVC gel soft actuators. The results show the effectiveness of the proposed system and suggest the feasibility of PVC gel soft actuators for developing practical soft wearable assistive devices, informing the development of future wearable robots and the other soft actuator technologies for human movement assistance and rehabilitation.

  7. Micellar and analytical implications of a new potentiometric PVC sensor based on neutral ion-pair complexes of dodecylmethylimidazolium bromide-sodium dodecylsulfate.

    Science.gov (United States)

    Sanan, Reshu; Mahajan, Rakesh Kumar

    2013-03-15

    With an aim to characterize the micellar aggregates of imidazolium based ionic liquids, a new potentiometric PVC sensor based on neutral ion-pair complexes of dodecylmethylimidazolium bromide-sodium dodecylsulfate (C12MeIm(+)DS(-)) has been developed. The electrode exhibited a linear response for the concentration range of 7.9×10(-5)-9.8×10(-3) M with a super-Nernstian slope of 92.94 mV/decade, a response time of 5 s and critical micellar concentration (cmc) of 10.09 mM for C12MeImBr. The performance of the electrode in investigating the cmc of C12MeImBr in the presence of two drugs [promazine hydrochloride (PMZ) and promethazine hydrochloride (PMT)] and three triblock copolymers (P123, L64 and F68) has been found to be satisfactory on comparison with conductivity measurements. Various micellar parameters have been evaluated for the binary mixtures of C12MeImBr with drugs and triblock copolymers using Clint's, Rubingh's, and Motomura's approach. Thus the electrode offers a simple, straightforward and relatively fast technique for the characterization of micellar aggregates of C12MeImBr, complementing existing conventional techniques. Further, the analytical importance of proposed C12MeIm(+)-ISE as end point indicator in potentiometric titrations and for direct determination of cationic surfactants [cetylpyridinium chloride (CPC), tetradecyltrimethylammonium bromide (TTAB), benzalkonium chloride (BC)] in some commercial products was judged by comparing statistically with classical two-phase titration methods. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Optical acetylcholine sensor based on free base porphyrin as a chromoionophore.

    Science.gov (United States)

    Mroczkiewicz, Monika; Pietrzak, Mariusz; Górski, Łukasz; Malinowska, Elżbieta

    2011-09-21

    In this work, the possibility of application of free base porphyrin as a lipophilic pH chromoionophore for the preparation of optical cation-selective sensors was investigated. The properties of polymeric membranes, containing porphyrins of different structures, namely tetraphenylporphyrin (TPP) and octaethylporphyrin (OEP), were compared. Changes in equilibrium between protonated and deprotonated form of porphyrin, resulting from variations in ACh concentration, were evaluated. The influence of various factors (kind and quantity of anionic additive and porphyrin in the membrane phase, pH of sample solution) on initial equilibrium was studied. The best membrane composition was chosen as: TPP 3 wt.%, KTFPB 175 mol.% relative to ionophore, PVC:o-NPOE (1 : 4) and measuring buffer solution: 0.05 M MES, pH 4.5. Selectivity, response stability, reversibility and repeatability tests were carried out for chosen sensor. Developed sensor allowed for the determination of a model analyte, acetylcholine, at the concentration range of 10(-5) to 10(-2) M, both in stationary and flow-injection system. Sensor response was reversible and repeatable in the mentioned concentration range.

  9. Preparation of Drug-loaded Chitosan Microspheres and Its Application in Paper-based PVC Wallpaper

    Science.gov (United States)

    Lin, Hui; Chen, Lihui; Yan, Guiyang; Chen, Feng; Huang, Liulian

    2018-03-01

    By screening through test, it was found that the drug-loaded chitosan microspheres with the average particle size of 615 nm may be prepared with NaF as the mold-proof drug, chitosan as the drug carrier and sodium tripolyphosphate as the cross-linking agent; and they can improve the aspergillus niger-proof effect if loaded onto the base paper surface of the paper-based PVC wallpaper. The results show that NaF and chitosan have mold-proof synergistic effects; the mold-proof effect of the wallpaper may be improved by increasing the dose of chitosan; when the mass ratio of NaF, sodium tripolyphosphate and chitosan was 2:7:28, the paper-based PVC wallpaper with good mold-proof property can be prepared.

  10. Development of Fabric-Based Chemical Gas Sensors for Use as Wearable Electronic Noses

    Directory of Open Access Journals (Sweden)

    Thara Seesaard

    2015-01-01

    Full Text Available Novel gas sensors embroidered into fabric substrates based on polymers/ SWNT-COOH nanocomposites were proposed in this paper, aiming for their use as a wearable electronic nose (e-nose. The fabric-based chemical gas sensors were fabricated by two main processes: drop coating and embroidery. Four potential polymers (PVC, cumene-PSMA, PSE and PVP/functionalized-SWCNT sensing materials were deposited onto interdigitated electrodes previously prepared by embroidering conductive thread on a fabric substrate to make an optimal set of sensors. After preliminary trials of the obtained sensors, it was found that the sensors yielded a electrical resistance in the region of a few kilo-Ohms. The sensors were tested with various volatile compounds such as ammonium hydroxide, ethanol, pyridine, triethylamine, methanol and acetone, which are commonly found in the wastes released from the human body. These sensors were used to detect and discriminate between the body odors of different regions and exist in various forms such as the urine, armpit and exhaled breath odor. Based on a simple pattern recognition technique, we have shown that the proposed fabric-based chemical gas sensors can discriminate the human body odor from two persons.

  11. Development of fabric-based chemical gas sensors for use as wearable electronic noses.

    Science.gov (United States)

    Seesaard, Thara; Lorwongtragool, Panida; Kerdcharoen, Teerakiat

    2015-01-16

    Novel gas sensors embroidered into fabric substrates based on polymers/ SWNT-COOH nanocomposites were proposed in this paper, aiming for their use as a wearable electronic nose (e-nose). The fabric-based chemical gas sensors were fabricated by two main processes: drop coating and embroidery. Four potential polymers (PVC, cumene-PSMA, PSE and PVP)/functionalized-SWCNT sensing materials were deposited onto interdigitated electrodes previously prepared by embroidering conductive thread on a fabric substrate to make an optimal set of sensors. After preliminary trials of the obtained sensors, it was found that the sensors yielded a electrical resistance in the region of a few kilo-Ohms. The sensors were tested with various volatile compounds such as ammonium hydroxide, ethanol, pyridine, triethylamine, methanol and acetone, which are commonly found in the wastes released from the human body. These sensors were used to detect and discriminate between the body odors of different regions and exist in various forms such as the urine, armpit and exhaled breath odor. Based on a simple pattern recognition technique, we have shown that the proposed fabric-based chemical gas sensors can discriminate the human body odor from two persons.

  12. Economic sensitivity of DAW incineration to PVC content

    International Nuclear Information System (INIS)

    Rossmassler, R.L.

    1986-01-01

    Economic analyses of the volume reduction of low level radwaste, including the incinerator of Dry Active Waste (DAW), spent resins and filter sludges, are performed using the microcomputer code VOLREDUCER. Based on BWR and PWR data taken from previous EPRI work, the sensitivity of incinerator economics to polyvinyl chloride (PVC) content in DAW is examined. An annual cost penalty associated with the presence of PVC in the waste is formulated, and the sensitivity of this penalty to a variety of parameters is determined. The alternative of sorting out PVC from the rest of the waste is compared to incineration with regard to this annual cost penalty. These penalties may range as high as $100,000 annually depending on the waste characteristics and percent of PVC

  13. Antibacterial performance of ZnO-based fillers with mesoscale structured morphology in model medical PVC composites

    Energy Technology Data Exchange (ETDEWEB)

    Machovsky, Michal; Kuritka, Ivo, E-mail: ivo@kuritka.net; Bazant, Pavel; Vesela, Daniela; Saha, Petr

    2014-08-01

    Three different ZnO-based antibacterial fillers having different morphologies in microscale region were prepared by the use of the microwave assisted synthesis protocol created in our laboratory with additional annealing in one case. Further, PVC composites containing 0.5–5 wt.% of ZnO based antibacterial fillers were prepared by melt mixing and characterized by scanning electron microscopy (SEM) and X-ray diffractometry (XRD). Mechanical testing showed no adverse effect on the working of polymer composites due to either of the fillers used or the applied processing conditions in comparison with the neat medical grade PVC. The surface antibacterial activity of the compounded PVC composites was assessed against Escherichia coli ATCC 8739 and Staphylococcus aureus ATCC 6538P according to ISO 22196: 2007 (E). All materials at almost all filler loading levels were efficient against both species of bacteria. The material with the most expanding morphology assuring the largest contact between filler and matrix achieved an excellent level of more than 99.9999% reduction of viable cells of E. coli in comparison to untreated PVC and performed very well against S. aureus, too. A correlation between the morphology and efficacy of the filler was observed and, as a result, a general rule was formulated which links the proneness of the microparticles to perform well against bacteria to their shape and morphology. - Highlights: • ZnO-based nanostructured microparticles were prepared by microwave synthesis. • Prepared ZnO imparts excellent antibacterial activity to PVC composites. • The microparticulate character of filler makes it processable as common powders. • The inevitable disadvantages of nanoparticles are circumvented. • General rule of proneness of microparticles for antibacterial composites.

  14. Antibacterial performance of ZnO-based fillers with mesoscale structured morphology in model medical PVC composites

    International Nuclear Information System (INIS)

    Machovsky, Michal; Kuritka, Ivo; Bazant, Pavel; Vesela, Daniela; Saha, Petr

    2014-01-01

    Three different ZnO-based antibacterial fillers having different morphologies in microscale region were prepared by the use of the microwave assisted synthesis protocol created in our laboratory with additional annealing in one case. Further, PVC composites containing 0.5–5 wt.% of ZnO based antibacterial fillers were prepared by melt mixing and characterized by scanning electron microscopy (SEM) and X-ray diffractometry (XRD). Mechanical testing showed no adverse effect on the working of polymer composites due to either of the fillers used or the applied processing conditions in comparison with the neat medical grade PVC. The surface antibacterial activity of the compounded PVC composites was assessed against Escherichia coli ATCC 8739 and Staphylococcus aureus ATCC 6538P according to ISO 22196: 2007 (E). All materials at almost all filler loading levels were efficient against both species of bacteria. The material with the most expanding morphology assuring the largest contact between filler and matrix achieved an excellent level of more than 99.9999% reduction of viable cells of E. coli in comparison to untreated PVC and performed very well against S. aureus, too. A correlation between the morphology and efficacy of the filler was observed and, as a result, a general rule was formulated which links the proneness of the microparticles to perform well against bacteria to their shape and morphology. - Highlights: • ZnO-based nanostructured microparticles were prepared by microwave synthesis. • Prepared ZnO imparts excellent antibacterial activity to PVC composites. • The microparticulate character of filler makes it processable as common powders. • The inevitable disadvantages of nanoparticles are circumvented. • General rule of proneness of microparticles for antibacterial composites

  15. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier.

    Science.gov (United States)

    Zamani, Hassan Ali; Zanganeh-Asadabadi, Abbas; Rohani, Mitra; Zabihi, Mohammad Saleh; Fadaee, Javad; Ganjali, Mohammad Reza; Faridbod, Farnoush; Meghdadi, Soraia

    2013-03-01

    In this research, we report a new Ho(3+)-PVC membrane electrode based on N-(4,5-dimethyl-2-(picolinamido)phenyl)picolinamide (H(2)Me(2)bpb) as a suitable ion carrier. Poly vinylchloride (PVC)-based membrane composed of H(2)Me(2)bpb with oleic acid (OA) as anionic additives, and o-nitrophenyloctyl ether (NPOE) as plasticized solvent mediator. The sensor exhibits a Nernstian slope of 20.1 ± 0.2 mV decade(-1) over the concentration range of 1.0 × 10(-6) to 1.0 × 1(-2) mol L(-1), and a detection limit of 5.0 × 10(-7) mol L(-1) of Ho(3+) ions. The potentiometric response of the sensor is independent of the solution pH in the range of 3.5-9.4. It has a very short response time, in the whole concentration range (titration of Ho(3+) ion solutions in certified reference materials, alloy samples and for the determination of the fluoride ion in two mouthwash preparations. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. PET and PVC Separation with Hyperspectral Imagery

    Directory of Open Access Journals (Sweden)

    Monica Moroni

    2015-01-01

    Full Text Available Traditional plants for plastic separation in homogeneous products employ material physical properties (for instance density. Due to the small intervals of variability of different polymer properties, the output quality may not be adequate. Sensing technologies based on hyperspectral imaging have been introduced in order to classify materials and to increase the quality of recycled products, which have to comply with specific standards determined by industrial applications. This paper presents the results of the characterization of two different plastic polymers—polyethylene terephthalate (PET and polyvinyl chloride (PVC—in different phases of their life cycle (primary raw materials, urban and urban-assimilated waste and secondary raw materials to show the contribution of hyperspectral sensors in the field of material recycling. This is accomplished via near-infrared (900–1700 nm reflectance spectra extracted from hyperspectral images acquired with a two-linear-spectrometer apparatus. Results have shown that a rapid and reliable identification of PET and PVC can be achieved by using a simple two near-infrared wavelength operator coupled to an analysis of reflectance spectra. This resulted in 100% classification accuracy. A sensor based on this identification method appears suitable and inexpensive to build and provides the necessary speed and performance required by the recycling industry.

  17. Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes

    Directory of Open Access Journals (Sweden)

    Eman Y. Z. Frag

    2011-01-01

    Full Text Available This study compares between unmodified carbon paste (CPE; the paste has no ion pair and polyvinyl chloride (PVC membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF, where sodium tetraphenylborate (NaTPB was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10−7 to 10−2 mol L−1. The electrodes show Nernstian slope value of 52.51±0.20 and 51.51±0.25 mV decade−1 for CPE and PVC membrane electrodes at 30∘C, respectively. The potential is nearly stable over the pH range 3.0–6.0 and 2.0–7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets, and biological fluid (urine. The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97±0.53 and 98.62±0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.

  18. Potentiometric determination of ketotifen fumarate in pharmaceutical preparations and urine using carbon paste and PVC membrane selective electrodes.

    Science.gov (United States)

    Frag, Eman Y Z; Mohamed, Gehad G; Khalil, Mohamed M; Hwehy, Mohammad M A

    2011-01-01

    This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10(-7) to 10(-2) mol L(-1). The electrodes show Nernstian slope value of 52.51 ± 0.20 and 51.51 ± 0.25 mV decade(-1) for CPE and PVC membrane electrodes at 30°C, respectively. The potential is nearly stable over the pH range 3.0-6.0 and 2.0-7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets), and biological fluid (urine). The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97 ± 0.53 and 98.62 ± 0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.

  19. Mercury(II) selective sensors based on AlGaN/GaN transistors

    International Nuclear Information System (INIS)

    Asadnia, Mohsen; Myers, Matthew; Akhavan, N.D.; O'Donnell, Kane; Umana-Membreno, Gilberto A.; Mishra, U.K.; Nener, Brett; Baker, Murray; Parish, Giacinta

    2016-01-01

    This work presents the first polymer approach to detect metal ions using AlGaN/GaN transistor-based sensor. The sensor utilised an AlGaN/GaN high electron mobility transistor-type structure by functionalising the gate area with a polyvinyl chloride (PVC) based ion selective membrane. Sensors based on this technology are portable, robust and typically highly sensitive to the target analyte; in this case Hg 2+ . This sensor showed a rapid and stable response when it was introduced to solutions of varying Hg 2+ concentrations. At pH 2.8 in a 10 −2  M KNO 3 ion buffer, a detection limit below 10 −8  M and a linear response range between 10 −8  M-10 −4  M were achieved. This detection limit is an order of magnitude lower than the reported detection limit of 10 −7  M for thioglycolic acid monolayer functionalised AlGaN/GaN HEMT devices. Detection limits of approximately 10 −7  M and 10 −6  M in 10 −2  M Cd(NO 3 ) 2 and 10 −2  M Pb(NO 3 ) 2 ion buffers were also achieved, respectively. Furthermore, we show that the apparent gate response was near-Nernstian under various conditions. X-ray photoelectron spectroscopy (XPS) experiments confirmed that the sensing membrane is reversible after being exposed to Hg 2+ solution and rinsed with deionised water. The success of this study precedes the development of this technology in selectively sensing multiple ions in water with use of the appropriate polymer based membranes on arrays of devices. - Highlights: • This work is the first polymer approach to detect metal ions using AlGaN/GaN transistor-based sensor. • The sensor utilised an AlGaN/GaN transistor by functionalising the gate area with a polyvinyl chloride (PVC) based membrane. • The sensor showed a rapid and linear response between 10 −8 M-10 −4 M for Hg 2+ detection at pH 2.8 in a 10 −2 M KNO 3 ion buffer. • Detection limits of approximately 10 −7 M and 10 −6 M in 10 −2 M Cd(NO 3 ) 2 and 10 −2 M Pb(NO 3 ) 2 ion buffers

  20. Studies on heat shrinkage PVC tubes

    International Nuclear Information System (INIS)

    Pyun, Hyung Chick; Kim, Ki Yup; Nho, Young Chang

    1991-01-01

    Radiation crosslinking of PVC was investigated for the purpose of obtaining a suitable formulation for heat shrinkable tube. PVC was not only compounded with various crosslinking agents and plasticizers to evaluate their effects on the radiation sensitivity, heat shrinkable property and other mechanical properties, but also mixed with NBR, crosslinking agents and plasticizers to obtain efficient crosslinking yield and suitable mechanical properties for heat shrinkable tube. Gel yield of PVC increased with increasing unsaturation levels per molecular weight of crosslinking agents. Among crosslinking agents tested, TMPTMA with three unsaturated groups showed highest gel yield, while PVC containing NBR was more sensitive to crosslinking than PVC itself regardless the types of crosslinking agents and plasticizers. Tensile strength was increased with increasing radiation dose and gel percent, but elongation decreased. It was found that gel percent was increased with increasing radiation dose, heat transformation was decreased with increasing gel percent. When NBR was mixed with PVC, the radiation dosage required for enhancing yield of gel percent and heat transformation were found to be much smaller comparing with the case containing no NBR. Therefore, the addition of NBR to PVC was very effective to increase heat-resisting property of PVC. Heat shrinkage was not much varied with radiation dose, the types of crosslinking agents and plasticizers, but it was increased remarkably with decreasing stretching temperature and increasing annealing temperature. (Author)

  1. Preparation and characterization of a sulindac sensor based on PVC/TOA-SUL membrane.

    Science.gov (United States)

    Lenik, Joanna

    2014-04-01

    A potentiometric sulindac sensitive sensor based on tetraoctylammonium (Z)-5-fluoro-2-methyl-1-[[p-(methylsulfinyl)phenyl]methylene]-1H-indene-3-acetate (TOA-SUL) was described. The electrode responded with sensitivity of 57.5±1.6mV decade(-1) over the linear range 5×10(-5)-1×10(-2)mol L(-1) at pH6.0-9.0. It had the limit of detection 1.4×10(-5)mol L(-1), a fast response time of 13s and showed clear discrimination of sulindac ions from several inorganic and organic compounds and also amino acids. This electrode did not contain any inner solutions, so it was easy and comfortable to use. The proposed sensor was used to determine sulindac in clear solution and in urine sample solution. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Anion recognition using newly synthesized hydrogen bonding disubstituted phenylhydrazone-based receptors: poly(vinyl chloride)-based sensor for acetate.

    Science.gov (United States)

    Gupta, Vinod K; Goyal, Rajendra N; Sharma, Ram A

    2008-08-15

    A potentiometric acetate-selective sensor, based on the use of butane-2,3-dione,bis[(2,4-dinitrophenyl)hydrazone] (BDH) as a neutral carrier in poly(vinyl chloride) (PVC) matrix, is reported. Effect of various plasticizers and cation excluder, cetryaltrimethylammonium bromide (CTAB) was studied. The best performance was obtained with a membrane composition of PVC:BDH:CTAB ratio (w/w; mg) of 160:8:8. The sensor exhibits significantly enhanced selectivity toward acetate ions over a wide concentration range 5.0 x 10(-6) to 1.0 x 10(-1)M with a lower detection limit of 1.2 x 10(-6)M within pH range 6.5-7.5 with a response time of Fast and stable response, good reproducibility and long-term stability are demonstrated. The sensor has a response time of 15s and can be used for at least 65 days without any considerable divergence in their potential response. Selectivity coefficients determined with the separate solution method (SSM) and fixed interference method (FIM) indicate that high selectivity for acetate ion. The proposed electrode shows fairly good discrimination of acetate from several inorganic and organic anions. It was successfully applied to direct determination of acetate within food preservatives. Total concentration of acetic acid in vinegar samples were determined by direct potentiometry and the values agreed with those mentioned by the manufacturers.

  3. PVC pipes in gas distribution: still going strong!

    NARCIS (Netherlands)

    Hermkens, Rene; Wolters, Mannes; Weller, Jeroen; Visser, Roy; Davidovski, Z.; Belloir, P.; Fumire, J.

    2008-01-01

    In the Netherlands (impact-modified) PVC is the preferred material for low-pressure (30 and 100 mbar) gas distribution systems. More than 50% of the total length (about 122,000 km) of this system is rigid PVC or impact-modified PVC. The installation of rigid PVC (uPVC) pipelines started about 50

  4. Infrared studies of PVC-based electrolytes incorporated with lithium triflate and 1-butyl-3-methyl imidazolium trifluoromethanesulfonate as ionic liquid

    Science.gov (United States)

    Zulkepeli, Nik A. S. Nik; Winie, Tan; Subban, R. H. Y.

    2017-09-01

    In this work, 1-butyl-3-methylimidazolium trifluoromethanesulfonate (BMIMCF3SO3) is employed as ionic liquid in PVC-based polymer electrolyte system with lithium triflate (LiCF3SO3) as doping salt. The samples in film form were prepared by quantitatively varying the concentration of BMIMCF3SO3 to a fixed ratio of PVC-LiCF3SO3 using solution cast technique. The highest room temperature ionic conductivity of 1.120 × 10-7 Scm-1 was exhibited by PVC-LiCF3SO3-BMIMCF3SO3 containing 3 wt. % BMIMCF3SO3. FTIR spectra of the polymer electrolytes were examined to study the complexation of the PVC-based polymer electrolytes. Intensity of free ions, ion pairs, and ion aggregates were obtained from FTIR deconvolution in an attempt to correlate with ionic conductivity results. The intensity of free ions was found to be high for sample with 3 wt. % BMIMCF3SO3.

  5. Evaluation of retail fresh meat packagings covered with stretch films of plasticized PVC and non-PVC alternatives

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Togeskov, P.; Hallas, J.

    2004-01-01

    The characteristics and performance of several non-PVC stretch films were compared to those of plasticized PVC. Initially the main polymer components Of the film were identified by infrared spectrometry and differential scanning calorimetry. The differences between films in mechanical properties......, such as puncture resistance and tensile strength, varied about a factor of two, while the differences in elongation at break were considerably higher. Plasticized PVC showed properties somewhere in the middle. The water vapour transmission was highest for PVC, while its permeability to oxygen was the lowest...

  6. Properties of lightweight aggregate concrete prepared with PVC granules derived from scraped PVC pipes.

    Science.gov (United States)

    Kou, S C; Lee, G; Poon, C S; Lai, W L

    2009-02-01

    This paper aims to investigate the fresh and hardened properties of lightweight aggregate concretes that are prepared with the use of recycled plastic waste sourced from scraped PVC pipes to replace river sand as fine aggregates. A number of laboratory prepared concrete mixes were tested, in which river sand was partially replaced by PVC plastic waste granules in percentages of 0%, 5%, 15%, 30% and 45% by volume. Two major findings are identified. The positive side shows that the concrete prepared with a partial replacement by PVC was lighter (lower density), was more ductile (greater Poisson's ratios and reduced modulus of elasticity), and had lower drying shrinkage and higher resistance to chloride ion penetration. The negative side reveals that the workability, compressive strength and tensile splitting strength of the concretes were reduced. The results gathered would form a part of useful information for recycling PVC plastic waste in lightweight concrete mixes.

  7. Australia slaps duties on PVC imports

    International Nuclear Information System (INIS)

    Young, I.

    1992-01-01

    The Australian Anti-Dumping Authority (ADA0) has imposed dumping duties on imports of polyvinyl chloride (PVC) resin from seven countries and on certain expanded polystyrene (EPS) beads from Korea and Singapore. The decisions come at the end of two separate investigations begun earlier this year. In its first finding, the ADA concluded that there has been dumping of PVC resin from Canada, China, France, Japan, Norway, Saudi Arabia, and Thailand, which has caused and threatens to cause material injury to the domestic PVC industry. An eighth country, Romania, was found not to have been exporting PVC to Australia. The case is the second of its kind in Australia focusing on PVC. In December 1991 the ADA found in favor of local producer sin a dumping complaint against Argentina, Brazil, Hungary, Israel, Korea, Mexico, Poland, Singapore, Taiwan, and the US

  8. Electron beam crosslinked PVC : structure property relationships

    International Nuclear Information System (INIS)

    Gupta, Neeraj K.; Sabharwal, Sunil

    2001-01-01

    PVC is used extensively for its insulating properties for the manufacture of wires and cables and for other applications. Its gradual degradation, oxidation and even dehydro chlorination restricts use for long lasting period in installations such as high temperature zones, underground cables, communication systems, electro-nuclear facilities, etc. The technological properties and performance characteristics of PVC based insulation can be improved via crosslinking by high-energy electrons. PVC is however a polymer, which on irradiation predominantly undergoes degradation. To avoid degradation, it needs to be compounded with sensitizing agents or multifunctional monomers so that crosslinking is the predominant reaction. Radiation cross linkable formulations are complex mixtures of resin and various additives incorporated for achieving desired technological and performance characteristics, ease of processing and improving quality. The proper choice of additives and sensitizing agents enable low dose requirements for efficient crosslinking and improvements in various technological properties. The purposes of this work was to investigate the effect of using a binary sensitizer blend of a trifunctional monomer and a rubber in PVC, and develop suitable electron beam cross linkable formulations for wire insulation. This paper presents some aspects of the investigations and development of insulation demonstrated at industrial scale

  9. The Modification of Fuel Cell-Based Breath Alcohol Sensor Materials to Improve Water Retention of Sensing Performance

    Science.gov (United States)

    Allan, Jesse

    are better suited for sensor applications. The commercially used porous poly-vinyl chloride (PVC) membrane was investigated and modified to improve performance of this material. As PVC does not contain any natural hydroscopic properties, the addition of various hydrophilic groups to the PVC would aid in water management. It was found that while chemical modification could improve water retention, optimization of the modifications would be required to ensure flooding was not an issue. Composites of PVC and sulfonated silica showed performance that matched that of the commercial PVC, whilst using significantly less water to achieve those results. By reducing the water required for sensing, leaching of acid, as well as flooding could be reduced. Finally, the catalyst layer and gas diffusion layer (GDL) were investigated to understand what properties of these would impart the best performance increases for the sensor. For the catalyst layer, it was found that platinum black and 20% platinum supported on carbon achieved similar results. Platinum black has excellent catalytic activity for the ethanol oxidation reaction, while the surface area of the 20% platinum supported on carbon would allow for more ethanol to react, increasing the overall sensor capability. The choice of catalyst was less of an issue than the choice of GDL. It was found that using carbon fiber paper GDLs lead to greater retention of water in the MEA compared to carbon cloth GDLs due to the lower air permeability. This came at a cost however in that with a lower air permeability, less ethanol vapour would reach the catalytic sites, reducing sensing performance. Depending on the choice of membrane, removal of the GDL could impart performance increases, but could also cause detrimental failure in the case of Nafion based systems.

  10. Preparation of Gas Sensor Based on Polymer Nanocomposite for Qualitative Detection of Hydrogen Sulfide

    Directory of Open Access Journals (Sweden)

    Elaheh Ghazizadeh

    2016-11-01

    Full Text Available Hydrogen sulfide (H2S, a by-product often produced in petrochemical processes, is well known as a dangerous and highly toxic gas to living organisms. The smell of H2S concentration of higher than 100 ppm can cause severe biological condition. Therefore, the detection of this gas is a crucial issue. In this work, nanocomposite porous films of polyurethane/silver (PU/Ag and poly(vinylchloride/silver (PVC/Ag consisting of 7 wt% nanoparticles were fabricated by phase inversion method and studied its qualitative detection capacity for H2S. The results indicated that after exposure to 50 ppm H2S, black points appeared on the surface of the test films within 10 min. However, the color completely disappeared when the films were left in the air for 20 min. Structural characteristics of the nanocomposites were studied by scanning electron microscopy (SEM, Fourier transform infrared spectroscopy (FTIR, X-ray diffractometry (XRD and thermal gravimetric analysis (TGA to confirm possible interactions which may have formed between the polymers and nanoparticles. According to the results, Ag nanoparticles were well dispersed in PU and PVC matrices giving particle sizes of less than 62 and 76 nm, respectively. The observations revealed that two recommended nanocomposites (PU/Ag and PVC/Ag could be used for detection of hydrogen sulfide at low level concentration. The response of Ag-embedded polymer films toward H2S vapour showed a better detection by PU/Ag compared to PVC/Ag. Therefore, the suggested silver nanoparticle-loaded PU and PVC sensor films are easily portable, simple to use and cost-less compared with other types of hydrogen sulfide sensors.

  11. Mercury(II) selective sensors based on AlGaN/GaN transistors

    Energy Technology Data Exchange (ETDEWEB)

    Asadnia, Mohsen, E-mail: mohsen.asadnia@mq.edu.au [School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia); Department of Engineering, Macquarie University, NSW 2109 (Australia); Myers, Matthew [School of Chemistry and Biochemistry, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia); CSIRO Energy Flagship, Kensington, Western Australia 6151 (Australia); Akhavan, N.D. [School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia); O' Donnell, Kane [Department of Imaging and Applied Physics, Curtin University, Bentley, Western Australia 6102 (Australia); Umana-Membreno, Gilberto A. [School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia); Mishra, U.K. [Electrical and Computer Engineering Department, University of California, Santa Barbara, CA 93106 (United States); Nener, Brett [School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia); Baker, Murray [School of Chemistry and Biochemistry, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia); Parish, Giacinta [School of Electrical, Electronic and Computer Engineering, The University of Western Australia, 35 Stirling Hwy., Crawley, Western Australia 6009 (Australia)

    2016-11-02

    This work presents the first polymer approach to detect metal ions using AlGaN/GaN transistor-based sensor. The sensor utilised an AlGaN/GaN high electron mobility transistor-type structure by functionalising the gate area with a polyvinyl chloride (PVC) based ion selective membrane. Sensors based on this technology are portable, robust and typically highly sensitive to the target analyte; in this case Hg{sup 2+}. This sensor showed a rapid and stable response when it was introduced to solutions of varying Hg{sup 2+} concentrations. At pH 2.8 in a 10{sup −2} M KNO{sub 3} ion buffer, a detection limit below 10{sup −8} M and a linear response range between 10{sup −8} M-10{sup −4} M were achieved. This detection limit is an order of magnitude lower than the reported detection limit of 10{sup −7} M for thioglycolic acid monolayer functionalised AlGaN/GaN HEMT devices. Detection limits of approximately 10{sup −7} M and 10{sup −6} M in 10{sup −2} M Cd(NO{sub 3}){sub 2} and 10{sup −2} M Pb(NO{sub 3}){sub 2} ion buffers were also achieved, respectively. Furthermore, we show that the apparent gate response was near-Nernstian under various conditions. X-ray photoelectron spectroscopy (XPS) experiments confirmed that the sensing membrane is reversible after being exposed to Hg{sup 2+} solution and rinsed with deionised water. The success of this study precedes the development of this technology in selectively sensing multiple ions in water with use of the appropriate polymer based membranes on arrays of devices. - Highlights: • This work is the first polymer approach to detect metal ions using AlGaN/GaN transistor-based sensor. • The sensor utilised an AlGaN/GaN transistor by functionalising the gate area with a polyvinyl chloride (PVC) based membrane. • The sensor showed a rapid and linear response between 10{sup −8} M-10{sup −4} M for Hg{sup 2+} detection at pH 2.8 in a 10{sup −2} M KNO{sub 3} ion buffer. • Detection limits of

  12. PVC Membrane Sensors for Potentiometric Determination of Acebutolol

    Directory of Open Access Journals (Sweden)

    Abdulrahman Al-Majed

    2007-12-01

    Full Text Available The construction and general performance characteristics of two novelpotentiometric membrane sensors responsive to the acebutolol are described. Thesensors are based on the use of ion-association complexes of acebutolol (AC withtetraphenylborate(TPB (I and phosphomolybdate(PM (II as exchange sites in a PVCmatrix. The sensors show a fast, stable and near- Nernstian for the mono charge cationof AC over the concentration range 1×10-3 - ~10-6 M at 25 °C over the pH range 2.0 -6.0 with cationic slope of 51.5 ± 0.5 and 53.0 ± 0.5 per concentration decade for AC-Iand AC-II sensors respectively. The lower detection limit is 6×10-6 M and 4×0-6 M withthe response time 20-30 s in the same order of both sensors. Selectivity coefficients ofAC related to a number of interfering cation and some organic compounds wereinvestigated. There are negligible interferences are caused by most of the investigatedspecies. The direct determination of 3 - 370 μg/ml of AC shows an average recovery of 99.4 and 99.5% and a mean relative standard deviation of 1 . 5 % at 100.0 μg/ml forsensor I and II respectively. The results obtained by determination of AC in tablets usingthe proposed sensors which comparable favorably with those obtained by the Britishpharmacopoeia method. In the present investigation the electrodes have been utilized asend point indicator for some precipitation titration reactions.

  13. Planar potentiometric sensors based on Au and Ag microelectrodes and conducting polymers for flow-cell analysis

    International Nuclear Information System (INIS)

    ToczyIowska, Renata; Pokrop, RafaI; Dybko, Artur; Wroblewski, Wojciech

    2005-01-01

    Back-side contact Au and Ag microelectrodes were used as transducers to construct planar all-solid-state electrodes suitable for flow-through analysis. The microsensors were based on plasticized PVC potassium-selective membranes containing ion-electron conducting polymer-polypyrrole doped with di(2-ethylhexyl) sulfosuccinate. The proposed technique allowed simple construction of microsensors in one step, by membrane solution casting directly on the surface of the planar metallic transducers. The performance of the microsensors based on Au and Ag transducers were determined and compared with planar sensors based on internal electrolyte immobilized in polyHEMA. The addition of the polypyrrole to the membrane composition did not influence on the selectivity, reproducibility and long-term stability of the microsensors but improved their standard potential stability in time in comparison with coated-wire type sensors. Moreover, all-solid-state microsensors based on Au transducers exhibited better signal stability than Ag based sensors

  14. Recycling of PVC Waste via Environmental Friendly Vapor Treatment

    Science.gov (United States)

    Cui, Xin; Jin, Fangming; Zhang, Guangyi; Duan, Xiaokun

    2010-11-01

    This paper focused on the dechlorination of polyvinyl chloride (PVC), a plastic which is widely used in the human life and thereby is leading to serious "white pollution", via vapor treatment process to recycle PVC wastes. In the process, HCl emitted was captured into water solution to avoid hazardous gas pollution and corruption, and remaining polymers free of chlorine could be thermally degraded for further energy recovery. Optimal conditions for the dechlorination of PVC using vapor treatment was investigated, and economic feasibility of this method was also analyzed based on the experimental data. The results showed that the efficiency of dechlorination increased as the temperature increased from 200° C to 250° C, and the rate of dechlorination up to 100% was obtained at the temperature near 250° C. Meanwhile, about 12% of total organic carbon was detected in water solution, which indicated that PVC was slightly degraded in this process. The main products in solution were identified to be acetone, benzene and toluene. In addition, the effects of alkali catalysis on dechlorination were also studied in this paper, and it showed that alkali could not improve the efficiency of the dechlorination of PVC.

  15. RETGEM with polyvinylchloride (PVC) electrodes

    CERN Document Server

    Razin, V I; Reshetin, A I; Filippov, S N

    2009-01-01

    This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC in the case of high counting rates without of the transit to the violent sparks. The distinct feature of present RETGEM is the absent of the metal coating and lithographic technology for manufacturing of the protective dielectric rms. The electrodes from PVC permit to do the holes by a simple drilling machine. Detectors on a RETGEM basis could be useful in many fields of an application requiring a more cheap manufacturing and safe operation, for example, in a large neutrino experiments, in TPC, RICH systems.

  16. Discoloration of plasticized PVC upon irradiation

    International Nuclear Information System (INIS)

    Kojima, Keiichi; Ueno, Keiji; Kumafuji, Hisao.

    1981-01-01

    The effects of the factors on the discoloration of PVC cross-linked by electron irradiation, such as irradiation dose, the polymerization degree of PVC resin, plasticizers and stabilizers, were studied. The composition of the plasticized PVC used for the experiment was 100 PHR of PVC, 50 PHR of plasticizer, 5 PHR of stabilizer and 5 PHR of cross-linking agent (TMPMA). Three samples with the different degree of polymerization of the PVC resin were used, namely 750, 1050 and 2600. As the plasticizers, phthalic acid esters (DBP, DOP, DIDP), trimellitic acid esters (TOTM, n-TOTM), fatty acid esters (DOS, DOZ), polyester and epoxy group plasticizers were used. The irradiation dose for the test was 3, 6 and 12 Mrad. The experimental results are summarized as follows. As the electron irradiation dose was higher, the resultant discoloration was more remarkable, and the optimum irradiation dose was below 6 Mrad. The degree of polymerization of the PVC resin did not affect the irradiation discoloration. However it was noticed that the cross-linking efficiency was better as the degree of polymerization was higher. The cross-linking efficiency was better as the content of plasticizer was more. The fatty acid esters and epoxy groups showed less discoloration and better cross-linking efficiency. Tin and barium-zinc stabilizers were good. (Kako, I.)

  17. Effect of PVC on ionic conductivity, crystallographic structural, morphological and thermal characterizations in PMMA-PVC blend-based polymer electrolytes

    International Nuclear Information System (INIS)

    Ramesh, S.; Liew, Chiam-Wen; Morris, Ezra; Durairaj, R.

    2010-01-01

    In this paper, temperature dependence of ionic conductivity, crystallographic structural, morphological and thermal characteristics of polymer blends of PMMA and PVC with lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) as a dopant salt are investigated. The study on the temperature dependence of ionic conductivity shows that these polymer blends exhibit Arrhenius behavior. The highest ionic conductivity was achieved when 70 wt% of PMMA was blended with 30 wt% of PVC. X-ray diffraction (XRD) and scanning electron microscopy (SEM) reveal the amorphous nature and surface morphology of polymer electrolytes, respectively. In DSC analysis it was found that the glass transition temperature (T g ) and melting temperature (T m ) decreased, whereas the decomposition temperature (T d ) increased. In contrast, the shift towards higher decomposition temperature and decrease in weight loss of polymer electrolytes, in TGA studies, indicates that the thermal stability of polymer electrolytes improved.

  18. THE STUDY OF TECHNOLOGICAL PROPERTIES OF PLASTISOLS BASED EMULSION PVC FILLED WITH CHALK GIDROFOBIZIROVANNYM

    Directory of Open Access Journals (Sweden)

    V. A. Sedykh

    2014-01-01

    Full Text Available Baby toys are made using the centrifugal molding plastisol based emulsion of polyvinyl chloride plasticized with dioctylphthalate. To reduce cost and decrease biotelemetry the dioctylphthalate on the surface of the product domestic toys than toys produced in China, there was a necessity of introduction of the filler is chalk from different manufacturers. By using a Brookfield vis-cometer PV-D was studied rheology of filled hydrophobized chalk PVC plastisols in storage conditions for up to 72 hours at temperatures of 14-20°C. It was found that the flow plastisols consistent with pseudo-plastic fluids. Given the flow rates of emulsion PVC plastisols filled to 35 % of the mass. hydrophobized chalk. The influence of the content of the plasticizer dioctylphthalate in a narrow interval (37,0 - 41,4 % of the mass. on the viscosity of polymer pastes and the kinetics of its changes during storage. Revealed a linear dependence of the viscosity of the filled hydrophobized chalk plastisols on the speed of rotation of the spindle of the viscometer and during storage. Given the rate of expansion changes the viscosity of the plastisols of the speed of rotation of the spindle of the viscometer, the rate of change in viscosity and calculation of the initial viscosity. Determined the stability of the dispersion hydrophobized chalk in a colloidal solution of PVC in dioctylphthalate during storage. We determined the variation of the content of chalk (ash with top and bottom layers plastisols height 8 cm after 24 hours storage. It is proved that the temperature of the preparation and storage of polymer pastes were determining factors in the regulation of such technological properties of PVC plastisols in the presence hydrophobized chalkas viscosity, stability of the dispersion of chalk and, consequently, the efficiency of distribution plastisols in the form of a centrifugal molding.

  19. Effect of PVC on ionic conductivity, crystallographic structural, morphological and thermal characterizations in PMMA-PVC blend-based polymer electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, S., E-mail: rameshtsubra@gmail.com [Centre for Ionics University Malaya, Department of Physics, Faculty of Science, University of Malaya, Lembah Pantai, 50603 Kuala Lumpur (Malaysia); Liew, Chiam-Wen; Morris, Ezra; Durairaj, R. [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Setapak, 53300 Kuala Lumpur (Malaysia)

    2010-11-20

    In this paper, temperature dependence of ionic conductivity, crystallographic structural, morphological and thermal characteristics of polymer blends of PMMA and PVC with lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) as a dopant salt are investigated. The study on the temperature dependence of ionic conductivity shows that these polymer blends exhibit Arrhenius behavior. The highest ionic conductivity was achieved when 70 wt% of PMMA was blended with 30 wt% of PVC. X-ray diffraction (XRD) and scanning electron microscopy (SEM) reveal the amorphous nature and surface morphology of polymer electrolytes, respectively. In DSC analysis it was found that the glass transition temperature (T{sub g}) and melting temperature (T{sub m}) decreased, whereas the decomposition temperature (T{sub d}) increased. In contrast, the shift towards higher decomposition temperature and decrease in weight loss of polymer electrolytes, in TGA studies, indicates that the thermal stability of polymer electrolytes improved.

  20. A reciclagem de PVC no Brasil

    OpenAIRE

    Piva,Ana Magda; Bahiense Neto,Miguel; Wiebeck,Hélio

    1999-01-01

    Esta pesquisa discute as possibilidades práticas da reciclagem de PVC. Na reciclagem de polímeros, a do PVC representa uma importante parcela. PVC é um polímero que é usado em uma ampla faixa de produtos: filmes, fios, cabos, em compostos para uma variedade de formas. A reciclagem é uma técnica vantajosa, capaz de reproduzir as propriedades do polímero original, no polímero reciclado e isto em condições razoavelmente econômicas. A tecnologia brasileira, em relação a produtos reciclados, apres...

  1. Construction and demolition waste as a source of PVC for recycling.

    Science.gov (United States)

    Prestes, Sabrina Moretto Darbello; Mancini, Sandro Donnini; Rodolfo, Antonio; Keiroglo, Raquel Carramillo

    2012-02-01

    Construction and demolition waste can contain considerable amounts of polyvinyl chloride (PVC). This paper describes a study of the recycling of PVC pipes collected from such waste materials. In a sorting facility for the specific disposal of construction and demolition waste, PVC was found to represent one-third of the plastics separated by workers. Pipes were sorted carefully to preclude any possible contamination by poly(ethylene terephthalate) (PET) found in the waste. The material was ground into two distinct particle sizes (final mesh of 12.7 and 8 mm), washed, dried and recycled. The average formulation of the pipes was determined based on ash content tests and used in the fabrication of a similar compound made mainly of virgin PVC. Samples of recycled pipes and of compound based on virgin material were subjected to tensile and impact tests and provided very similar results. These results are a good indication of the application potential of the recycled material and of the fact that longer grinding to obtain finer particles is not necessarily beneficial.

  2. Radiation crosslinking of PVC with polyfunctional monomers

    International Nuclear Information System (INIS)

    Dobo, J.; Takacs, E.; Csato, P.

    1984-01-01

    The radiation crosslinking of PVC in the presence of ethylene glycol dimethacrylate (EGDM) and of trimethylol propane trimethacrylate (TMPTM) was investigated. The effect of PVC powders of different types on the polymerization rate of these monomers was studied by a Calvet-type microcalorimeter. In the milled PVC sheets containing 50 part EGDM a high concentration of trapped free radicals was found by ESR after 16 months storage. (author)

  3. Designed biocompatible nano-inhibitor based on poly(β-cyclodextrin-ester) for reduction of the DEHP migration from plasticized PVC.

    Science.gov (United States)

    Raeisi, Ahmad; Faghihi, Khalil; Shabanian, Meisam

    2017-10-15

    The easy migration of di(2-ethylhexyl) phthalate (DEHP) from the plasticized PVC (P-PVC) poses a serious threat to human health and the ecosystems. Thus, its control migration from the P-PVC products is very important. In this work, a poly(β-cyclodextrin-ester) network (β-CDP) was synthesized via reaction of β-cyclodextrin with 3,3',4,4'-benzophenone tetracarboxylic dianhydride. As a potential inhibitor for reduction of the DEHP migration, the β-CDP was grafted to Fe 3 O 4 nanoparticles. Poly(β-cyclodextrin-ester) functionalized Fe 3 O 4 nanoparticles (MNP-CDP) has been used in PVC/DEHP system as a reactive nano-inhibitor to reduce DEHP migration. Thermal stability and mechanical properties of obtained films were investigated. DEHP migration tests of the P-PVC films were also carried out by using Gas chromatography. It was found that by incorporating the small amounts of nano-inhibitor in PVC/DEHP system, the migration of DEHP effectively reduced from the P-PVC samples about 65% without any serious changes in mechanical and thermal properties of the P-PVC films. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. A new PVC based membrane sensor of dibenzo-18-crown-6 for strontium

    International Nuclear Information System (INIS)

    Singh, Ashok K.; Bhattacharjee, G.; Baniwal, Seema; Singh, Manendra

    1999-01-01

    Dibenzo-18-crown-6 crown ether is found to exhibit quite promising selectivity for Sr 2+ ions. It can be used to estimate strontium in the range 5.0 x 10 -6 to 1.0 x 10 -1 mol dm -3 (0.28 to 8.76 x 10 -3 mg dm -3 ) with a near-Nernstian slope of 28 mV per decade of concentration. The working pH range of the proposed sensor is 2.0-6.0 with a response time of 25 s. The sensor can be used for more than three months in aqueous as well as in partially non-aqueous media. The practical utility of the membrane sensor has also been observed in solutions contaminated with detergent matter. (author)

  5. Hoechst and Wacker plan joint venture in PVC

    International Nuclear Information System (INIS)

    Young, I.

    1992-01-01

    Restructuring of Europe's petrochemical industry has taken a further step with the announcement that Hoechst (Frankfurt) and Wacker Chemie (Munich) are planning a joint venture in polyvinyl chloride (PVC). The venture would include production, R ampersand D, sales and marketing, plus both companies' PVC recycling activities. However, their vinyl chloride monomer (VCM) plants, and Hoechst's Kalle PVC film business, have been left out. Erich Schnitzler, head of Hoechst's PVC business unit, does not anticipate problems with the European Community's competition directorate. We are both among the middle-sized European PVC producers, and together we would have a 9%-10% market share. Our joint venture would not limit competition. Both partners are hoping for approval from Brussels in first-quarter 1993. Hoechst has 255,000 m.t./year of PVC capacity at Gendorfand Knapsack, while Wacker has 365,000 m.t./year at Burghausen and Cologne. All the units, except Wacker's Cologne plant, are back integrated to VCM. The joint venture would buy VCM from the two parent companies and on the merchant market

  6. New potentiometric sensor based on molecularly imprinted nanoparticles for cocaine detection.

    Science.gov (United States)

    Smolinska-Kempisty, K; Ahmad, O Sheej; Guerreiro, A; Karim, K; Piletska, E; Piletsky, S

    2017-10-15

    Here we present a potentiometric sensor for cocaine detection based on molecularly imprinted polymer nanoparticles (nanoMIPs) produced by the solid-phase imprinting method. The composition of polymers with high affinity for cocaine was optimised using molecular modelling. Four compositions were selected and polymers prepared using two protocols: chemical polymerisation in water and UV-initiated polymerisation in organic solvent. All synthesised nanoparticles had very good affinity to cocaine with dissociation constants between 0.6nM and 5.3nM. Imprinted polymers produced in organic solvent using acrylamide as a functional monomer demonstrated the highest yield and affinity, and so were selected for further sensor development. For this, nanoparticles were incorporated within a PVC matrix which was then used to prepare an ion-selective membrane integrated with a potentiometric transducer. It was demonstrated that the sensor was able to quantify cocaine in blood serum samples in the range of concentrations between 1nM and 1mM. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Chalk effect on PVC cross-linking under irradiation

    International Nuclear Information System (INIS)

    Chudinova, V.V.; Guzeev, V.V.; Mozzhukhin, V.B.; Pomerantseva, Eh.G.; Nozrina, F.D.; Zhil'tsov, V.V.; Zubov, V.P.

    1994-01-01

    Effect of nonmodified and modified chalk on curing degree of polymer matrix was studied under-irradiation of PVC-compositions. Films of the compositions (100 mass part 7 PVC, 0-100 mas.part of chalk, 2.5 - lead sulfate, 1.5 - lead stearate and 0.3 - glycerin) were irradiated up to absorbed dose 0.1 MGy in an inert medium. Content of gel-fraction after boiling in THF was determined with use of IR spectroscopy. It was established, that intensive dehydrochlorination and polymer curing took place on chalk particle surface. Network fixed strongly chalk particles. However, chalk inhibited processes of dehydrochlorination and PVC curing, increasing amount of noncured PVC in polymer matrix

  8. Electrochemical Behaviour of Ni and Ni-PVC Electrodes for the Electroxidation of Ethanol

    International Nuclear Information System (INIS)

    Mohd Syafiq Hamdan; Norazzizi Nordin; Siti Fathrita Mohd Amir; Riyanto; Mohamed Rozali Othman

    2011-01-01

    In this study, two nickel based electrodes were prepared; nickel foil and nickel-polyvinylchloride (Ni-PVC), in order to study their electrochemical behavior using cyclic voltammetry, CV and chronocoulometry, CC. Ni electrode was prepared from Ni metal foil while Ni-PVC electrode was prepared by mixing a weighed portion of Ni powder and PVC in THF solvent, swirled until the suspension was homogeneous and drying the suspension in an oven at 50 degree Celsius for 3 h. The dry sample was then placed in a 1 cm diameter stainless steel mould and pressed at 10 ton/ cm 2 . From CV data, Ni-PVC electrode showed a better electrochemical behavior compared to Ni metal foil electrode. The use of Ni-PVC electrode at higher concentration of supporting electrolyte (1.0 M KOH) was better than at lower concentration of the same supporting electrolyte in electroxidation of ethanol. In addition to acetic acid, the oxidation of ethanol also produced ethyl acetate and acetaldehyde. (author)

  9. Studies of PVC/ENR blends: blend compositions

    International Nuclear Information System (INIS)

    Chantara Thevy Ratnam; Khairul Zaman Mohd Dahlan; Nasir, M.; Baharin, A.

    2002-01-01

    Blends of poly(vinyl chloride/epoxidized natural rubber (PVC/ENR) were prepared by using Bra bender Plasticorder at compositions ranging from 0-100% PVC. They were blended at 150 degree C mixing temperature, 50 rpm rotor speed and 10 minutes mixing time. The blends were characterized for tensile strength , elongation at break, glass transition temperatures and Fourier transform infra red spectroscopy (FTIR). Results revealed that as the PVC content increases the blend behaviour changes from elastomeric to glassy. However the blends found to be compatible at all compositions. (Author)

  10. Radiation cross-linked PVC and its applications

    International Nuclear Information System (INIS)

    Lan Junming; Chen Ruyan; Jia Chaoxing; Li Min; Li Chengxin

    1990-04-01

    The radiation cross-linking technique is adopted for improving the polyvinyl chloride (PVC) heat-resistance and reducing its thermocontractibility. For examining its properties a small insulation sheath made from modified PVC material has been tested at 260 0 5 seconds. The results obtained were satisfactory

  11. Comparative Study of PVC-Free All-Solid-State, PVC Membrane, and Carbon Paste Ion-Selective Electrodes for the Determination of Dapoxetine Hydrochloride in Pharmaceutical Formulation.

    Science.gov (United States)

    Aziz, Azza; Khamees, Nesrin; Mohamed, Tagreed Abdel-Fattah; Derar, Abeer Rashad

    2016-11-01

    The potentiometric response characteristics and analytical applications of a poly(vinyl chloride) (PVC)-free all-solid-state ion-selective electrode for dapoxetine hydrochloride (DAP) are examined. The Nernstian response of the electrode was evaluated by comparison with PVC-based liquid membrane and carbon paste electrodes. The PVC-free electrode is prepared by direct incorporation of dapoxetine-tetraphenyl borate (DAP-TPB) as a sensing element into a commercial nail varnish containing cellulose acetate propionate. The composite was applied onto a 3 mm diameter graphite disk electrode. The electrode exhibited a Nernstian slope of 56.0 mV/decade in the concentration range of 1 × 10-4 to 1 × 10-2 mol/L with an LOD of 2 × 10-5 mol/L. The electrode is independent of pH in the range of 2 to 6 and showed good selectivity for DAP with respect to a large number of inorganic cations and amino acids. Comparable Nernstian slope, sensitivity, pH range, and selectivity pattern were obtained with a PVC membrane and a carbon paste incorporating DAP-TPB as a sensing element and dioctylphthalate as a solvent mediator. The electrodes were used for the determination of DAP in pure solution and in tablets without extraction with high accuracy and precision (RSD ≤ 2%). The nail varnish solid-state electrode is simple, economical, and rapid when compared with PVC membrane and carbon paste electrodes.

  12. Structure and performance of ZnO/PVC nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Elashmawi, I.S., E-mail: islam_shukri2000@yahoo.co [Spectroscopy department, Physics division, National Research Centre, Dokki (Egypt); Hakeem, N.A. [Spectroscopy department, Physics division, National Research Centre, Dokki (Egypt); Marei, L.K.; Hanna, F.F. [Faculty of Petroleum and Mining Engineering, Suez Canal University, Suez (Egypt)

    2010-10-01

    ZnO/PVC nanocomposites films have been prepared by the solvent casting method and investigated by various techniques. All results show good dispersion of ZnO nanoparticles in the polymeric matrix. XRD revealed that pure PVC films are partially crystalline with hallow peak but ZnO nanoparticles have wurtzite structure and the nanocomposite films were almost the same as those of ZnO with decrease in the degree of crystallization, causing increase in the amorphous region. FT-IR presented the same spectra for nanocomposites in the wavenumber range 700-3100 cm{sup -1}, weak band located at 500-700 cm{sup -1},which can be attributed to stretching of Zn---O bond and an increase of the bending band of O-H at 1631 cm{sup -1} was observed. The surface of the films was analyzed by SEM, which becomes rough with some small aggregates compared with pure PVC with good distribution in the entire surface region with bright spots. TEM revealed a regular crystalline lattice superimposed on an amorphous background due to carbon support and PVC matrix and the structure of these particles is hexagonal. In addition, the nanocomposites films have higher glass transition temperature, specific heat and thermal stability relative to those of pure PVC because of strong interaction among ZnO nanoparticles and PVC.

  13. Study of microporous PVA/PVC composite polymer membrane and it application to MnO2 capacitors

    International Nuclear Information System (INIS)

    Yang, C.-C.; Wu, G.M.

    2009-01-01

    A microporous poly(vinyl alcohol)/poly(vinyl chloride) (PVA/PVC) composite polymer membrane was successfully synthesized by a solution casting method and a preferential dissolution method. The characteristic properties of PVA/PVC composite polymer membranes were systematically studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermal gravimetric analysis (TGA), micro-Raman spectroscopy and AC impedance spectroscopy. The PVA/PVC composite polymer membrane shows excellent thermal property, dimensional stability, and the ionic conductivity; it is due to the addition of secondary PVC polymer fillers. The MnO 2 capacitors with the PVA/PVC composite polymer membrane with 1 M Na 2 SO 4 was assembled and examined. It was found that the MnO 2 capacitor based on a microporous PVA/5 wt.%PVC composite polymer electrolyte membrane exhibited the maximum specific capacitance of 238 F g -1 and the current efficiency of 99% at 25 mV s -1 after 1000 cycle test. The result demonstrates that the novel microporous PVA/PVC composite polymer membrane is a potential candidate for use on the capacitors

  14. Strawberries packaged with Polyvinyl Chloride (PVC film/ Morangos embalados com filme de Ppolicloreto de Vinila (PVC

    Directory of Open Access Journals (Sweden)

    Sergio Ruffo Roberto

    2006-06-01

    Full Text Available Strawberries cv. Dover with approximately 75% of their surface with red color was packaged in disposable polyethylene terephthalate (PET container and sealed with PVC film of 15mm thick. Strawberries without film serves as control. The fruits were stored at 12°C for ten days and there were determined during storage time the titratable acidity, solid soluble and vitamin C contents, color, respiration rate, texture and weight loss. After 6 days the strawberries packaged without film had decayed while the fruits packaged with PVC film were in conditions of consumption and commercialization. After 10 days all fruits were inappropriate to consumption. Packages with PVC film extended the shelf life of strawberries preserving the color characteristic of the product and vitamin C content, reducing the respiration rate and weight loss, characterizing this packaging as being adequate to this kind of product.Foram utilizados morangos cv. Dover com aproximadamente 75% de sua superfície com coloração vermelha e embalados em potes de polietileno tereftalato (PET. No tratamento CONTROLE os morangos foram acondicionados sem filme e no tratamento FILME, as embalagens foram seladas com filme de PVC de 15mm de espessura. As frutas foram armazenadas a 12°C por dez dias e foram determinadas ao longo do tempo acidez titulável, sólidos solúveis, vitamina C, cor, taxa de respiração, textura e perda de massa. Após 6 dias de armazenagem os morangos CONTROLE estavam impróprios para consumo pois apresentavam deterioração visível por bolores enquanto que os embalados com PVC estavam em condições de consumo e comercialização. Após 10 dias todos os morangos estavam impróprios para consumo. A embalagem utilizando filme de PVC aumentou a vida de prateleira de morangos em relação aos sem embalagem pois preservou melhor a coloração característica do produto e teor de vitamina C e reduziu as taxas de respiração e de perda de massa, caracterizando a

  15. Self-Plasticization of PVC via click reaction of a monooctyl phthalate derivative

    Directory of Open Access Journals (Sweden)

    Jia Puyou

    2017-09-01

    Full Text Available Modified PVC (M-PVC material with suppressed migration and low glass transition temperature was prepared via click reaction of a monooctyl phthalate derivative. Chemical structure and composition of M-PVC were characterized by FT-IR, 1H NMR and element analysis. Thermal stability, glass transition temperature and migration stability of M-PVC were studied with TGA, DSC and migration tests, respectively. The study showed that M-PVC exhibited poor thermal stability, and low glass transition temperature of 66.0°C. No migration was found in distilled water, 10% (v/v ethanol, 30% (w/vacetic acid and petroleum ether. The PVC material is expected to preparing PVC products in the areas with high migration resistance requirement.

  16. Effect of radiation on Poly Vinyl chloride (PVC)

    International Nuclear Information System (INIS)

    Massaud, F.; Haraga, S.; Benfaid, N.; Benayad, S.; Kabar, Y.; Elmesmary, Y; Elwerfeli, M.; Omran, Sh.

    1993-01-01

    Radiation crosslinking of polymeric materials is of increasing commercial importance because of the improved thermal, electrical and mechanical properties. Poly Vinylchloride (PVC) is one of the most important polymers. Many attempts were made to study the primary reactions induced by the direct effect of radiation on PVC. In this study, powder PVC was irradiated with different doses at ambient temperature. Formation of free radicals was investigated by electron spin resonance (ESR) method and molecular weight was determined by viscosity measurements. It has been observed that hydrogen chloride was evolved because of noticeable change in color. One type of radical, Poly enyl structure was trapped at room temperature. The non-symmetric singlet structure of the ESR spectra is due to the presence of oxygen. The radical concentration increased with increase of dose. The molecular weight of irradiated PVC was found to be inversely proportional to the increase of radiation dose, which is believed to be due to the occurrence of degradation. It can be concluded that gamma radiation will be the best method for crosslinking of PVC if multi-functional groups or monomers are present. (author)

  17. Strength analysis of welded corners of PVC window profiles

    Science.gov (United States)

    Postawa, P.; Stachowiak, T.; Gnatowski, A.

    2017-08-01

    The article presents the results of researches which main purpose was to define the influence of welding parameters on strength of welded corners of PVC window profile. PVC profiles of a branded name GENEO® produced by Rehau Company were used for this research. The profiles were made by using a co-extrusion method. The surface of the profile was made of PVC mixture with no additives. Its main task was to get a smooth surface resistant to a smudge. The use of an unfilled polyester provides an aesthetic look and improves the resistance of extrudate to water getting into inner layers. The profile's inner layers have been filled up with glass fibre in order to improve its stiffness and mechanical properties. Window frames with cut corners used for this research, were produced on technological line of EUROCOLOR Company based in Pyskowice (Poland). The main goal of this analysis was to evaluate the influence of the main welding parameter (temperature upsetting) on hardness of welds we received in whole process. A universal testing machine was used for the research.

  18. High Doses Gamma Radiolysis of PVC: Mechanisms of Degradation

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    PVC radiolysis leads to the formation of various degradation products: radicals, gas, oxidized products or polyenes. In order to predict the formation of the degradation products with regard to irradiation and ageing parameters, it is important to improve the understanding of the radiolysis mechanisms of PVC. Thus, we used several analytical techniques (Electron Spin Resonance, Fourier Transform Infrared spectroscopy, Nuclear Magnetic Resonance, Size Exclusion Chromatography) to get information on PVC samples irradiated at high doses (up to 4MGy) under different conditions. Gamma irradiation induces the formation of various radicals into PVC. Older studies were generally focused on the effect of low dose and/or low temperature irradiations on PVC. We present here ESR signals of PVC irradiated at high doses and at room temperature. We show that peroxyl radicals are producted by radiolysis under aerobe conditions and that polyenyl radicals are formed under anaerobe conditions. PVC radiolysis induces gas production and especially hydrogen chloride. Production of hydrogen chloride is well known until 1 MGy. We have studied by FTIR, the evolution of the quantity of HCl produced until 4 MGy. We show that higher irradiation dose leads to the lower radiolytic yield of HCl (G(HCl)). Moreover, G(HCl) obtained in aerobe conditions is about fourfold as great as G(HCl) observed in anaerobe radiolysis. Propagation and termination reactions induce degradation products: polyene sequences and crosslinking reactions are observed under anaerobe conditions; oxidized products with addition of chain scissions are formed under aerobe conditions. Although the literature about PVC radiolysis is rich, the main reacting pathways are not well established. Moreover the high doses studies are almost non-existent. We show by FTIR that aerobe radiolysis induces formation of ketons and acids. NMR experiments confirme these results but also focuse on small acids formed (with 2, 3 or 4 carbons). The

  19. Highly selective single-use fluoride ion optical sensor based on aluminum(III)-salen complex in thin polymeric film

    International Nuclear Information System (INIS)

    Badr, Ibrahim H.A.; Meyerhoff, Mark E.

    2005-01-01

    A highly selective optical sensor for fluoride ion based on the use of an aluminum(III)-salen complex as an ionophore within a thin polymeric film is described. The sensor is prepared by embedding the aluminum(III)-salen ionophore and a suitable lipophilic pH-sensitive indicator (ETH-7075) in a plasticized poly(vinyl chloride) (PVC) film. Optical response to fluoride occurs due to fluoride extraction into the polymer via formation of a strong complex with the aluminum(III)-salen species. Co-extraction of protons occurs simultaneously, with protonation of the indicator dye yielding the optical response at 529 nm. Films prepared using dioctylsebacate (DOS) are shown to exhibit better response (e.g., linear range, detection limit, and optical signal stability) compared to those prepared using ortho-nitrophenyloctyl ether (o-NPOE). Films formulated with aluminum(III)-salen and ETH-7075 indicator in 2 DOS:1 PVC, exhibit a significantly enhanced selectivity for fluoride over a wide range of lipophilic anions including salicylate, perchlorate, nitrate, and thiocyanate. The optimized films exhibit a sub-micromolar detection limit, using glycine-phosphate buffer, pH 3.00, as the test sample. The response times of the fluoride optical sensing films are in the range of 1-10 min depending on the fluoride ion concentration in the sample. The sensor exhibits very poor reversibility owing to a high co-extraction constant (log K = 8.5 ± 0.4), indicating that it can best be employed as a single-use transduction device. The utility of the aluminum(III)-salen based fluoride sensitive films as single-use sensors is demonstrated by casting polymeric films on the bottom of standard polypropylene microtiter plate wells (96 wells/plate). The modified microtiter plate optode format sensors exhibit response characteristics comparable to the classical optode films cast on quartz slides. The modified microtiter is utilized for the analysis of fluoride in diluted anti-cavity fluoride rinse

  20. Application of 1-ethyl-3-(2,5-dihydro-4-(3,5-dimethyl-1H-pyrazol-4-yl) -5-oxo-1H-pyrazol-3-yl)thiourea as sensing material for construction of Tm3+-PVC membrane sensor

    International Nuclear Information System (INIS)

    Zamani, Hassan Ali; Feizyzadeh, Babak; Faridbod, Farnoush; Ganjali, Mohammad Reza

    2011-01-01

    A thulium(III) membrane sensor was made using 2% sodium tetraphenyl borate (NaTPB), 65% dibutylphthalate (DBP), 30% poly(vinyl chloride) (PVC) and 3% 1-ethyl-3-(2,5-dihydro-4-(3,5-dimethyl-1H-pyrazol-4-yl) -5-oxo-1H-pyrazol-3-yl)thiourea (ET) as an ionophore. Conductometric study shows selectivity of the Et toward Tm 3+ ions. Nernstian response of 19.6 ± 0.4 mV per decade of thulium concentration was observed, and the electrode worked well in concentration range of 1.0 x 10 -6 to 1.0 x 10 -2 mol L -1 with a lower detection limit (LDL) of 7.2 x 10 -7 mol L -1 , in a pH range of 4.3-10.4. The selectivity of the sensor over alkaline, alkaline earth, transition and heavy metal ions was also found to be in a satisfactory range. To check the analytical applicability of the proposed Tm 3+ sensor, it was successfully used as an indicator electrode in analysis of thulium in certified reference materials. - Research highlights: → This work reports development of polymeric membrane sensor for Tm3+ determination in certified reference materials. → The novelty of this work is based on the high affinity of the ionophore toward the Tm3+ ions which causes the high selectivity of the sensor. → The newly developed sensor is superior to the formerly reported Tm3+ sensors in terms of selectivity and detection limit.

  1. Preparation of Non-Woven Fiber Mats by Mixture of PVC and Epoxidized Natural Rubber

    International Nuclear Information System (INIS)

    Muhammad Hariz Othman; Mahathir Mohamed; Dahlan Mohd

    2014-01-01

    Eletrospun non-woven fibre mats prepared from ENR modified PVC were successfully fabricated at ambient temperature by electro spinning method. Liquid epoxidized natural rubber (LENR) was used because it is easier to handle compared to dried ENR. PVC was mixed with LENR based on 3 different ratios (9:1, 8:2 and 7:3). The effect of ENR on electrospinnibality of PVC was investigated.The morphologies and thermal properties of the electro span fibre mats were characterized and assessed using scanning calorimetry (DSC). The polymer solution concentration 16 aut % formed a diameter of the fibres were mainly affected by the addition of natural rubber and weight ratio of the solution. The diameter of the fibres also decreased with increasing amount of LENR in the solution. Thermal degradation involved two-step degradation with the first degradation representing the dehydro chlorination of PVC to form polyene and followed by the decomposition of LENR and the polyene.Addition of LENR into the sample caused the T g of electro spun fibre mats of PVC/LENR to shift toward lower temperature. (author)

  2. PVC removal from mixed plastics by triboelectrostatic separation

    International Nuclear Information System (INIS)

    Park, Chul-Hyun; Jeon, Ho-Seok; Park, Jai-Koo

    2007-01-01

    Ever increasing oil price and the constant growth in generation of waste plastics stimulate a research on material separation for recycling of waste plastics. At present, most waste plastics cause serious environmental problems due to the disposal by reclamation and incineration. Particularly, polyvinyl chloride (PVC) materials among waste plastics generates hazardous HCl gas, dioxins containing Cl, and so on, which lead to air pollution and shorten the life of incinerator, and it makes difficultly recycling of other plastics. Therefore, we designed a bench scale triboelectrostatic separator for PVC removal from mixed plastics (polyvinyl chloride/polyethylene terephthalate), and then carried out material separation tests. In triboelectrostatic separation, PVC and PET particles are charged negatively and positively, respectively, due to the difference of the work function of plastics in tribo charger of the fluidized-bed, and are separated by means of splitter through an opposite electric field. In this study, the charge efficiency of PVC and PET was strongly dependent on the tribo charger material (polypropylene), relative humidity (below 30%), air velocity (over 10 m/s), and mixture ratio (PET:PVC = 1:1). At the optimum conditions (electrode potential of 20 kV and splitter position of -2 cm), PVC rejection and PET recovery in PET products were 99.60 and 98.10%, respectively, and the reproducibility of optimal test was very good (±1%). In addition, as a change of splitter position, we developed the technique to recover high purity PET (over 99.99%) although PET recovery decreases by degrees

  3. Polarizing PVC — A Discrepant Event

    Science.gov (United States)

    Headly, David; Karabatek, Mohamed

    2016-01-01

    Each year when teaching polarization phenomena and the Triboelectric Series in a unit on electrostatics, I would balance some rods (2-3 ft in length) made from wood, aluminum, PVC, and Plexiglas on an inverted watch glass and demonstrate to the class how a party balloon rubbed with fake rabbit fur (charging the balloon negative) would always attract the uncharged rods, causing them to rotate towards the balloon (see Fig. 1). The fact that a charged object always attracts a neutral object due to the induced dipole in the latter is a great way to test if something is in fact charged. Surprisingly, the PVC pipe would usually, but not always, repel the charged balloon and rotate away! Repulsion means that neither of the objects are electrically neutral. In a separate test, after rubbing together a Plexiglas rod with a polyethylene grocery bag (making the rod positively charged and the bag negatively charged), the PVC usually attracts the rod. With the help of a student as part of his senior project, I finally decided to investigate further the source of the negative charge that exists on PVC. Specifically, is it nothing more than static charge that builds up on the pipe from unavoidable contact with its surroundings, or is it somehow intrinsic to the manufacturing process?

  4. A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine

    International Nuclear Information System (INIS)

    Gupta, Vinod Kumar; Singh, A.K.; Gupta, Barkha

    2006-01-01

    A polyvinyl chloride (PVC) based membrane sensor for cerium ions was prepared by employing N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine as an ionophore, oleic acid (OA) as anion excluder and o-nitrophenyloctyl ether (o-NPOE) as plasticizer. The plasticized membrane sensor exhibits a Nernstian response for Ce(III) ions over a wide concentration range (1.41 x 10 -7 to 1.0 x 10 -2 M) with a limit of detection as low as 8.91 x 10 -8 M. It has a fast response time (<10 s) and can be used for 4 months. The sensor revealed a very good selectivity with respect to common alkali, alkaline earth and heavy metal ions. The response of the proposed sensor is independent of pH between 3.0 and 8.0. It was used as an indicator electrode in potentiometric titration of fluoride, carbonate and oxalate anions and determination of cerium in simulated mixtures

  5. A selective potentiometric copper (II) ion sensor based on the functionalized ZnO nanorods.

    Science.gov (United States)

    Khun, K; Ibupoto, Z H; Liu, X; Nur, O; Willander, M; Danielsson, B

    2014-09-01

    In this work, ZnO nanorods were hydrothermally grown on the gold-coated glass substrate and characterized by field emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD) techniques. The ZnO nanorods were functionalized by two different approaches and performance of the sensor electrode was monitored. Fourier transform infrared spectroscopy (FTIR) was carried out for the confirmation of interaction between the ionophore molecules and ZnO nanorods. In addition to this, the surface of the electrode was characterized by X-ray photoelectron spectroscopy (XPS) showing the chemical and electronic state of the ionophore and ZnO nanorod components. The ionophore solution was prepared in the stabilizer, poly vinyl chloride (PVC) and additives, and then functionalized on the ZnO nanorods that have shown the Nernstian response with the slope of 31 mV/decade. However, the Cu2+ ion sensor was fabricated only by immobilizing the selective copper ion ionophore membrane without the use of PVC, plasticizers, additives and stabilizers and the sensor electrode showed a linear potentiometric response with a slope of 56.4 mV/decade within a large dynamic concentration range (from 1.0 x 10(-6) to 1.0 x 10(-1) M) of copper (II) nitrate solutions. The sensor showed excellent repeatability and reproducibility with response time of less than 10 s. The negligible response to potentially interfering metal ions such as calcium (Ca2+), magnesium (Mg2+), potassium (K+), iron (Fe3+), zinc (Zn2+), and sodium (Na+) allows this sensor to be used in biological studies. It may also be used as an indicator electrode in the potentiometric titration.

  6. Desenvolvimento de PVC reforçado com fibras de vidro longas para fabricação de produtos moldados Long glass fiber reinforcement of PVC molding compounds

    Directory of Open Access Journals (Sweden)

    Leandro H. Grizzo

    2011-01-01

    Full Text Available Neste trabalho foi desenvolvido um método para reforçar PVC rígido com fibras de vidro longas através da incorporação pelo processo de recobrimento da fibra contínua com um composto de PVC plastificado. Posteriormente o filamento foi picotado para a formação de grânulos, com fibras de vidro já incorporadas, que foram misturados mecanicamente ao PVC rígido granulado para alimentação direta por moldagem. A moldagem por injeção direta foi realizada com sucesso não sendo necessário a compostagem prévia, o que foi considerado conveniente, pois reduziu as etapas de processamento da resina de PVC e que proporcionou, possivelmente, redução de custos, redução da degradação do comprimento médio das fibras de vidro e diminuição da possibilidade de degradação da resina de PVC. O reforçamento do PVC rígido com 20% em massa de fibras de vidro longas de comprimento inicial entre 13 e 14 mm resultou em adequadas propriedades mecânicas, bem superiores ao PVC rígido não reforçado. Os módulos (tração e flexão e a resistência ao impacto Charpy praticamente dobraram, mesmo com os compósitos apresentando grande quantidade de plastificante em sua formulação, que possibilita ao PVC ser utilizado em outras aplicações não antes possíveis como em peças técnicas de engenharia.In this paper, a method to reinforce rigid PVC with long glass fibers (LGF was developed through the incorporation of continuous glass fibers, as rovings, with plasticized vinyl matrix prepared by the wire coating technique. The plasticized vinyl rovings were pelletized. The pellets (13-14 mm were then blended to a granulated rigid PVC formulation and directly injection molded as testing specimens. The direct injection molding, eliminating the preliminary melt-compounding process, was achieved successfully, which was considered convenient because it reduced the number of processing steps, which allowed cutting expenses, reduced the deterioration of the

  7. Estudo de propriedades de PVC modificado com grupos alquila e benzila Study of the properties of PVC modified through substitution by alkyl and benzyl groups

    Directory of Open Access Journals (Sweden)

    G. M Vinhas

    2005-07-01

    Full Text Available O poli(cloreto de vinila (PVC é o segundo termoplástico mais consumido em todo o mundo, sendo considerado o mais versátil dentre os plásticos. A grande versatilidade do PVC deve-se a suas propriedades e também a sua adequação aos mais variados processos de transformação. Uma vez que a resina de PVC é atóxica e inerte, a escolha de aditivos com essas mesmas características, permite a fabricação de filmes para embalagens de alimentos e produtos médico-hospitalares. Entretanto, suas propriedades podem se alterar quando submetido a qualquer processo de esterilização, especialmente por radiação gama. Neste trabalho foi realizado um estudo sobre a flexibilidade e estabilidade frente à radiação gama do PVC modificado quimicamente. O PVC foi modificado pela substituição de átomos de cloro por grupos alquila e benzila através de reações com reagentes de Grignard. Amostras de PVC modificado foram caracterizadas por espectroscopia de ressonância magnética nuclear de hidrogênio (RMN ¹H, espectroscopia na região do infravermelho com transformada de Fourier e calorimetria diferencial exploratória. A degradação do PVC modificado, quando submetido à radiação gama, foi avaliada por seus parâmetros viscosimétricos. De uma forma geral, o PVC modificado apresentou maior estabilidade à radiação gama que o original. O polímero modificado por substituição do cloro por grupo que contém um anel aromático foi o que apresentou maior estabilidade, quando submetido à dose de esterilização de 25 kGy. O PVC modificado apresentou temperaturas de transição vítrea ligeiramente mais baixas que o PVC original, indicando uma tendência ao aumento de flexibilidade pela presença de grupos alquila e benzila na cadeia do polímero.Poly(vinyl chloride (PVC ranks second among the most consumed thermoplastics in the world, and is considered the most versatile plastic. This versatility arises from its properties and suitability to a

  8. Degradation studies on plasticized PVC films submited to gamma radiation

    Directory of Open Access Journals (Sweden)

    Vinhas Glória Maria

    2003-01-01

    Full Text Available Poly (vinyl chloride, PVC, is a rigid polymer and for several of its applications must be compounded with plasticizing agents. The plasticizers minimize the dipolar interactions, which exist between the polymer's chains, promoting their mobility. In this work we studied the properties of PVC/plasticizer systems submitted to different doses of gamma radiation. We have used four commercial plasticizers amongt them di(2-ethylhexyl phthalate, DEHP, which is present in a great number of commercial applications. The PVC/plasticizer systems have been studied as films made by the solvent evaporation technique. Irradiated and non-irradiated films have been characterized by viscosimetric analysis, mechanical essays and infrared spectroscopy. The results have shown that the rigid, non plasticized, PVC film presented the greatest degradation index, while among the plasticized films the one which presented the larger degradation index due to chain scission was the DEHP plasticized PVC.

  9. Degradation studies on plasticised PVC films submitted to gamma radiation

    International Nuclear Information System (INIS)

    Vinhas, Gloria Maria; Souto-Maior, Rosa Maria; Lapa, Camila Maria; Almeida, Yeda Medeiros Bastos de

    2003-01-01

    Poly (vinyl chloride), PVC, is a rigid polymer and for several of its applications must be compounded with plasticizing agents. The plasticizers minimize the dipolar interactions, which exist between the polymer's chains, promoting their mobility. In this work we studied the properties of PVC/plasticizer systems submitted to different doses of gamma radiation. We have used four commercial plasticizers among them di(2-ethylhexyl) phthalate, DEHP, which is present in a great number of commercial applications. The PVC/plasticizer systems have been studied as films made by the solvent evaporation technique. Irradiated and non-irradiated films have been characterized by viscosimetric analysis, mechanical essays and infrared spectroscopy. The results have shown that the rigid, non plasticized, PVC film presented the greatest degradation index, while among the plasticised films the one which presented the larger degradation index due to chain scission was the DEHP plasticised PVC. (author)

  10. Application of time-of-flight mass spectrometry with laser-based photoionization methods for analytical pyrolysis of PVC

    Energy Technology Data Exchange (ETDEWEB)

    Streibel, T.; Muehlberger, F. [GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany); Adam, T.; Zimmermann, R. [Augsburg Univ. (Germany); Cao, L. [National Center for Iron and Steel, Beijing, BJ (China)

    2004-09-15

    Chlorinated benzenes and phenols generated from PVC pyrolysis are known to be precursors of PCDD/F formation. Therefore, selective and sensitive monitoring of these substances during PVC pyrolysis processes on an on-line, real-time basis could be very useful for the understanding of PCDD/F formation pathways. In this study, we investigated the pyrolysis gas from PVC samples derived from steel recycling by means of simultaneous single photon ionization/resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (SPI/REMPI-TOFMS). The application of these soft photo-ionization techniques in mass spectrometry enables a fast and comprehensive analysis of this complex matrix without generating fragment ions, which would interfere with molecule ions making interpretation of the obtained mass spectra very difficult.

  11. Preparation and characterization of PVC /ENR/CNTs Nano composites

    International Nuclear Information System (INIS)

    Ratnam, C.T.; Nur Azrini Ramlee; Keong, C.C.

    2011-01-01

    Poly (vinyl chloride), PVC/ epoxidized natural rubber blend, ENR/ carbon nano tubes, CNTs were prepared by using melt and solution blending methods. Addition of 2 phr of CNTs found to cause a drop in the tensile strength, Ts of the 50/ 50 PVC/ ENR blend. The nano composites prepared by the melt blending method exhibited higher values of Ts compared to the nano composites prepared by solution blending. Melt blending found to be an efficient method to prepare PVC/ ENR/ CNTs nano composites. (author)

  12. Study on Preparation and Properties of PVC Film Modified by Rare Earth

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The transparent PVC films were prepared by tape casting. In the process of preparation, rare earth nitrate, as a kind of modifier, was added to the solution of PVC and THF. These PVC films were tested after being crosslinked by ultraviolet light. It is found that the mechanical and physical properties of all the PVC films modified by rare earth nitrate are greatly enhanced.

  13. Effect of Modified Natural Rubber on PVC-ENR Electrospun Membrane: Thermal and Morphological Studies

    International Nuclear Information System (INIS)

    Mahathir Mohamed; Dahlan Mohd; Ratnam, C.T.; Pairu Ibrahim

    2016-01-01

    Electrospun fibers membrane (EFM) based on modified epoxidized natural rubber (ENR) and polyvinyl chloride (PVC) was successfully prepared by electro spinning technique. Epoxidized natural rubber was firstly prepared in solution by using 5 L flask and exposed to high intensity UV lamp for degradation. The PVC/ ENR mixture solution concentration were about 16 wt% and blended for 5 hours for homogeneity. The PVC/ ENR mixture were electro spun to form fibers membrane. The sample of electro spun fibers membrane were cured by electron beam. The resulting membranes were characterized for thermal and morphological studies. Thermal decomposition behavior of EFM was analyzed by thermogravimetric analysis (TGA). Thermo gram from TGA showed two stages of degradation for all formulation (90:10, 80:20, 70:30 PVC/ ENR) from 240 to 265 degree Celsius and 400 to 410 degree Celsius, respectively. From the DSC thermo gram of PVC/ ENR electro spun fibers showed that the addition of ENR resulted in the shifting of glass transition temperature (Tg) towards lower temperatures. The morphology of electro spun fibers was examined using scanning electron microscopy and it showed a variety of fiber morphologies. (author)

  14. Tratamento químico superficial e metalização de ABS, PVC e blendas de PVC/ABS

    Directory of Open Access Journals (Sweden)

    Ana Paula Kurek

    2015-04-01

    Full Text Available Visando à substituição do ABS em peças cromadas, amostras de PVC e blendas de PVC/ABS, na razão mássica de 20/80, 40/60 e 60/40, foram submetidas ao pré-tratamento em solução sulfocrômica sob diferentes condições de concentração, tempo e temperatura e sendo em seguida cromadas. As modificações na superfície das peças após o condicionamento foram analisadas por microscopia eletrônica de varredura, microscopia de força atômica e rugosidade. A qualidade da deposição metálica foi avaliada por inspeção visual e teste de adesão. Os resultados mostraram que, aumentando a concentração de PVC nas peças necessitou-se de condições operacionais mais agressivas, tais como maiores temperaturas de banho, tempo de imersão e concentração de solução sulfocrômica para que ocorresse a adesão da camada metálica. De todas as condições testadas com a solução condicionante sulfocrômica no tratamento das peças de PVC e blendas PVC/ABS de 20/80 e 40/60, a concentração de 350 g/L de ácido crômico e 400 g/L de ácido sulfúrico, temperatura de 70°C e tempo de imersão de 15 minutos, ocasionou deposição do metal em toda a superfície das peças, as quais foram aprovadas nos testes de adesão e corrosão.

  15. Mercury(II) selective sensors based on AlGaN/GaN transistors.

    Science.gov (United States)

    Asadnia, Mohsen; Myers, Matthew; Akhavan, N D; O'Donnell, Kane; Umana-Membreno, Gilberto A; Mishra, U K; Nener, Brett; Baker, Murray; Parish, Giacinta

    2016-11-02

    This work presents the first polymer approach to detect metal ions using AlGaN/GaN transistor-based sensor. The sensor utilised an AlGaN/GaN high electron mobility transistor-type structure by functionalising the gate area with a polyvinyl chloride (PVC) based ion selective membrane. Sensors based on this technology are portable, robust and typically highly sensitive to the target analyte; in this case Hg 2+ . This sensor showed a rapid and stable response when it was introduced to solutions of varying Hg 2+ concentrations. At pH 2.8 in a 10 -2  M KNO 3 ion buffer, a detection limit below 10 -8  M and a linear response range between 10 -8  M-10 -4  M were achieved. This detection limit is an order of magnitude lower than the reported detection limit of 10 -7  M for thioglycolic acid monolayer functionalised AlGaN/GaN HEMT devices. Detection limits of approximately 10 -7  M and 10 -6  M in 10 -2  M Cd(NO 3 ) 2 and 10 -2  M Pb(NO 3 ) 2 ion buffers were also achieved, respectively. Furthermore, we show that the apparent gate response was near-Nernstian under various conditions. X-ray photoelectron spectroscopy (XPS) experiments confirmed that the sensing membrane is reversible after being exposed to Hg 2+ solution and rinsed with deionised water. The success of this study precedes the development of this technology in selectively sensing multiple ions in water with use of the appropriate polymer based membranes on arrays of devices. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  16. Improvement of PVC floor tiles by gamma radiation

    International Nuclear Information System (INIS)

    Plessis, T.A. du; Badenhorst, F.

    1988-01-01

    Gamma radiation presents a unique method of transforming highly plasticized PVC floor tiles, manufactured at high speed through injection moulding, into a high quality floor covering at a cost at least 30% less than similarly rated rubber tiles. A specially formulated PVC compound was developed in collaboration with a leading manufacturer of floor tiles. These tiles are gamma crosslinked in its shipping cartons to form a dimensionally stable product which is highly fire resistant and inert to most chemicals and solvents. These crosslinked tiles are more flexible than the highly filled conventional PVC floor tiles, scratch resistant and have a longer lifespan and increased colour fastness. These tiles are also less expensive to install than conventional rubber tiles. (author)

  17. Development of a continuous flow model system for studies of biofilm formation on polymers and its application on PVC-C and PVC-P

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Albrechtsen, Hans-Jørgen

    could be harvested from three different combinations of flow velocity and residence time. Biofilm formation was followed by ATP analysis on test material (chlorinated polyvinylchloride, PVC-C), negative control (stainless steel) and positive control (plasticized polyvinylchloride, PVC-P) incubated......-C, while most of the very deviating values for PVC-P were between 2-13,000 pg ATP/cm2. During 43 weeks of operation of the continuous flow model systems the biofilm formation increased on all three materials, with biofilm formation on PVC-C at the same level as on the negative steel control (values of 75...... system. In this study, a continuous flow model system was developed, for investigating biofilm formation on polymers, simulating conditions in the distribution system. Commercially available pipes were used for exchangeable test pieces, which allowed for testing over prolonged time periods. Test pieces...

  18. Manganese(III Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Eugenia Fagadar-Cosma

    2010-09-01

    Full Text Available Two manganese(III porphyrins: manganese(III tetraphenylporphyrin chloride and manganese(III-tetrakis(3-hydroxyphenylporphyrin chloride were tested as ionophores for the construction of new diclofenac−selective electrodes. The electroactive material was incorporated either in PVC or a sol−gel matrix. The effect of different plasticizers and additives (anionic and cationic on the potentiometric response was studied. The best results were obtained for the PVC membrane plasticized with dioctylphtalate and having sodium tetraphenylborate as a lipophilic anionic additive incorporated. The sensor response was linear in the concentration range 3 × 10−6 – 1 × 10−2 M with a slope of −59.7 mV/dec diclofenac, a detection limit of 1.5 × 10−6 M and very good selectivity coefficients. It was used for the determination of diclofenac in pharmaceutical preparations, by direct potentiometry. The results were compared with those obtained by the HPLC reference method and a good agreement was found between the two methods.

  19. Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing material

    International Nuclear Information System (INIS)

    Zamani, Hassan Ali; Mohammadhosseini, Majid; Haji-Mohammadrezazadeh, Saeed; Faridbod, Farnoush; Ganjali, Mohammad Reza; Meghdadi, Soraia; Davoodnia, Abolghasem

    2012-01-01

    According to a solution study which showed a selective complexation between N,N′-bis(methylsalicylidene)-2-aminobenzylamine (MSAB) and gadolinium ions, MSAB was used as a sensing element in construction of a gadolinium(III) ion selective electrode. Acetophenon (AP) was used as solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode showed a good selectivity towards Gd(III) ions over a wide variety of cations tested. The constructed sensor displayed a Nernstian behavior (19.7 ± 0.3 mV/decade) in the concentration range of 1.0 × 10 −6 to 1.0 × 10 −2 mol L −1 with detection limit of 5.0 × 10 −7 mol L −1 and a short response time ( 3+ –PVC membrane sensor based on an ion carrier as sensing material is introduced. ► This technique is very simple and it's not necessary to use sophisticated equipment. ► This sensor shows good selectivity against other metal ions.

  20. Fabrication of a highly selective cadmium (II) sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore

    Energy Technology Data Exchange (ETDEWEB)

    Ghaemi, Arezoo, E-mail: arezooghaemi@yahoo.com; Tavakkoli, Haman; Mombeni, Tayebeh

    2014-05-01

    A new cadmium (II) ion selective sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane (kryptofix5) as a supramolecular carrier has been developed. The membrane solutions containing polyvinyl chloride (PVC), plasticizer, sodium tetraphenylborate (NaTPB) as a lipophilic ionic additive and kryptofix5 as an ionophore were directly coated on the surface of graphite rods. The best composition of the coated membrane (w/w%) was found to be: 30.0% PVC, 61.0% dioctyl sebacate (DOS), 6.0% NaTPB and 3.0% kryptofix5. The sensor indicates a good linear response for Cd{sup 2+} cation over a wide concentration range from 1.0 × 10{sup −5} to 1.0 × 10{sup −1} M with a Nernstian slope of 29.8 ± 0.1 mV/decade and the detection limit is 8.4 × 10{sup −6} M. The response time of the sensor is 15 s and it can be used for 7 weeks without significant drift in potential. The sensor operates in the wide pH range of 1.0–6.0. This sensor reveals a very good selectivity toward Cd{sup 2+} ion over a wide range of alkali, transition and heavy metal cations. The sensor was used as an indicator electrode for potentiometric titration of Cd{sup 2+} using sodium fluoride and ethylenediaminetetraacetic acid (EDTA) solutions with a sharp potential change that occurred at the end point. In addition, the proposed sensor was successfully used for determination of Cd{sup 2+} cation in real water samples. - Graphical abstract: Fabrication of a highly selective cadmium (II) sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore. - Highlights: • Fabrication of a novel Cd{sup 2+} selective sensor with high sensitivity and selectivity • Using fabricated sensor in a wide pH range with fast response time • Replacing expensive techniques with this low cost sensor with low detection limit • Excellent capability of this sensor for measuring Cd{sup 2+} in real samples.

  1. ELECTROCHEMICAL OXIDATION OF ETHANOL USING Ni-Co-PVC COMPOSITE ELECTRODE

    Directory of Open Access Journals (Sweden)

    Riyanto Riyanto

    2011-07-01

    Full Text Available The morphological characteristics and electrochemical behavior of nickel metal foil (Ni, nickel-polyvinyl chloride (Ni-PVC and nickel-cobalt-polyvinyl chloride (Ni-Co-PVC electrodes in alkaline solution has been investigated. The morphological characteristics of the electrode surface were studied using SEM and EDS, while the electrochemical behavior of the electrodes was studied using cyclic voltammetry (CV. It was found that composite electrodes (Ni-PVC and Ni-Co-PVC have a porous, irregular and rough surface. In situ studies using electrochemical technique using those three electrodes exhibited electrochemical activity for redox system, as well as selectivity in the electrooxidation of ethanol to acetic acid. The studies also found that an electrokinetics and electrocatalytic activity behaviors of the electrodes prepared were Ni metal foil

  2. Phthalate Migration Study from PVC Grafted by Gamma Radiation

    International Nuclear Information System (INIS)

    Manzoli, J.E.; Duarte, C.; Somesari, E.; Silveira, C.; Paes, H.A.; Manzoli, J.E.; Araujo, F.D.C.; Panzarini, L.C.G.A.

    2009-01-01

    PVC is a useful polymer used for many applications, as packaging of food, blood and in contact with body fluids. The most widely-used plasticizer, to make it flexible, is the phthalate DEHP, and its toxicity is a problem. A special radiation grafting of PVC allows an important reduction of thrombogenic properties, and it could cause changes in the DEHP migration too. In this work it is presented the methodology using gas chromatography and numerical simulation for the measurement of DEHP migration from PVC grafted with monomer DMAEMA. The grafting could be an interesting way to reduce DEHP migration

  3. Application of 1-ethyl-3-(2,5-dihydro-4-(3,5-dimethyl-1H-pyrazol-4-yl) -5-oxo-1H-pyrazol-3-yl)thiourea as sensing material for construction of Tm{sup 3+}-PVC membrane sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Quchan branch, Islamic Azad University, Quchan (Iran, Islamic Republic of); Feizyzadeh, Babak [Department of Applied Chemistry, Quchan branch, Islamic Azad University, Quchan (Iran, Islamic Republic of); Faridbod, Farnoush; Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of)

    2011-10-10

    A thulium(III) membrane sensor was made using 2% sodium tetraphenyl borate (NaTPB), 65% dibutylphthalate (DBP), 30% poly(vinyl chloride) (PVC) and 3% 1-ethyl-3-(2,5-dihydro-4-(3,5-dimethyl-1H-pyrazol-4-yl) -5-oxo-1H-pyrazol-3-yl)thiourea (ET) as an ionophore. Conductometric study shows selectivity of the Et toward Tm{sup 3+} ions. Nernstian response of 19.6 {+-} 0.4 mV per decade of thulium concentration was observed, and the electrode worked well in concentration range of 1.0 x 10{sup -6} to 1.0 x 10{sup -2} mol L{sup -1} with a lower detection limit (LDL) of 7.2 x 10{sup -7} mol L{sup -1}, in a pH range of 4.3-10.4. The selectivity of the sensor over alkaline, alkaline earth, transition and heavy metal ions was also found to be in a satisfactory range. To check the analytical applicability of the proposed Tm{sup 3+} sensor, it was successfully used as an indicator electrode in analysis of thulium in certified reference materials. - Research highlights: {yields} This work reports development of polymeric membrane sensor for Tm3+ determination in certified reference materials. {yields} The novelty of this work is based on the high affinity of the ionophore toward the Tm3+ ions which causes the high selectivity of the sensor. {yields} The newly developed sensor is superior to the formerly reported Tm3+ sensors in terms of selectivity and detection limit.

  4. Estudo do uso de plastificantes de fontes renovável em composições de PVC Study of the use of plasticizer from renewable sources in PVC compositions

    Directory of Open Access Journals (Sweden)

    Emerson Madaleno

    2009-01-01

    compositions of flexible PVC - based on two vegetable plasticizers from renewable sources (modified vegetable oil - OVM and epoxidized modified vegetable oil - OVME, in addition to two conventional petrochemical plasticizers, called di(2-ethylhexyl phthalate-(DEHP and di(2-ethylhexyl adipate-(DEHA. No significant differences were observed in the mechanical behavior of the compositions evaluated. The plasticizers affected the hardness and chemical resistance to n-heptane for the compositions. The epoxi group and the high molar mass from vegetable plasticizers showed better compatibility with the PVC resin. The analyses by SEM showed a probable exudation of OVM from the PVC matrix.

  5. PVC mixtures’ mechanical properties with the addition of modified calcite as filler

    Directory of Open Access Journals (Sweden)

    Vučinić Dušica R.

    2012-01-01

    Full Text Available In this study mechanical properties of PVC mixtures (PVC, stabilizer, lubricant, filler such as tensile strength, tensile elongation, breaking strength, and breaking elongation were investigated. Unmodified calcite, as well as calcite modified by stearic acid, were used as fillers in wet and dry processes. The PVC mixtures containing the calcite modified by wet procedure have better mechanical properties compared to those with the calcite modified by the dry process. Tensile and breaking strength of the PVC mixture containing the calcite modified with 1.5% stearic acid using wet process, are higher for 2.8% and 5.2%, respectively, compared to the PVC mixture containing the calcite modified with the same amount of acid used in the dry process. The tensile strength difference between the mixtures increases with the increase of the concentration of used stearic acid up to 3%. The strength of PVC mixture with the calcite modified by wet process is 3.1% higher compared to the mixture containing calcite modified by dry process. The results showed that the bonding strength between calcite and the adsorbed organic component affected tensile strength, tensile elongation and breaking strength of the PVC mixtures. The best filler was obtained by wet modification using 1.5% stearic acid solution that provided the formation of a stearate monolayer chemisorbed on calcite. The PVC mixtures containing the calcite modified by wet process using 1.5% stearic acid solution exhibited the best mechanical properties. This calcite was completely hydrophobic with dominant chemically adsorbed surfactant, which means that stearate chemisorbed on calcite provided stronger interaction in the calcite-stearic acid-PVC system.

  6. Tripodal chelating ligand-based sensor for selective determination of Zn(II) in biological and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Kumar Singh, Ashok; Mehtab, Sameena; Singh, Udai P.; Aggarwal, Vaibhave [Indian Institute of Technology-Roorkee, Department of Chemistry, Roorkee (India)

    2007-08-15

    Potassium hydrotris(N-tert-butyl-2-thioimidazolyl)borate [KTt{sup t-Bu}] and potassium hydrotris(3-tert-butyl-5-isopropyl-l-pyrazolyl)borate [KTp{sup t-Bu,i-Pr}] have been synthesized and evaluated as ionophores for preparation of a poly(vinyl chloride) (PVC) membrane sensor for Zn(II) ions. The effect of different plasticizers, viz. benzyl acetate (BA), dioctyl phthalate (DOP), dibutyl phthalate (DBP), tributyl phosphate (TBP), and o-nitrophenyl octyl ether (o-NPOE), and the anion excluders sodium tetraphenylborate (NaTPB), potassium tetrakis(p-chlorophenyl)borate (KTpClPB), and oleic acid (OA) were studied to improve the performance of the membrane sensor. The best performance was obtained from a sensor with a of [KTt{sup t-Bu}] membrane of composition (mg): [KTt{sup t-Bu}] (15), PVC (150), DBP (275), and NaTPB (4). This sensor had a Nernstian response (slope, 29.4 {+-} 0.2 mV decade of activity) for Zn{sup 2+} ions over a wide concentration range (1.4 x 10{sup -7} to 1.0 x 10{sup -1} mol L{sup -1}) with a limit of detection of 9.5 x 10{sup -8} mol L{sup -1}. It had a relatively fast response time (12 s) and could be used for 3 months without substantial change of the potential. The membrane sensor had very good selectivity for Zn{sup 2+} ions over a wide variety of other cations and could be used in a working pH range of 3.5-7.8. The sensor was also found to work satisfactorily in partially non-aqueous media and could be successfully used for estimation of zinc at trace levels in biological and environmental samples. (orig.)

  7. PVC makers study expansions to meet demand growth

    International Nuclear Information System (INIS)

    Hunter, D.; Coeyman, M.

    1993-01-01

    As prospects for the polyvinyl chloride (PVC) industry continue to improve, the next batch of capacity increases is being studied. Vista Chemical (Houston) sees an opportunity to achieve what company president James R. Ball calls the lowest-cost capacity addition in the market, by debottlenecking its PVC plants at Aberdeen, MS and Oklahoma City. That would increase capacity 40%, adding 300 million lbs/year to Vista's 830 million lbs/year. US demand for PVC grew 12.5% through the first 10 months of 1992, to 7.3 billion lbs, according to the latest figures available from the Society of the Plastics Industry. Alan Bailey, Oxy-Chem's executive v.p./polymers and plastics, predicts a good demand year in 1993 - better even than 1992, driven by an upward trend in housing starts and a recovering economy

  8. Thermal stability of formulations of PVC irradiated with {gamma} of {sup 60}; Estabilidad termica de formulaciones de PVC irradiadas con {gamma} de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M.E.; Carrasco A, H. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: memp@nuclear.inin.mx; Castaneda F, A.; Benavides C, R.; Garcia R, S.P. [CIQA, 25100 Saltillo, Coahuila (Mexico)

    2004-07-01

    The industry of cables and wires frequently use cable isolations with base of formulations of PVC, in those that stabilizer has usually been used with the help of heavy metals, as the lead, which is toxic. To solve the problem, from the 2002 one has come studying in combined form in the National Institute of Nuclear Research ININ and the Center of Investigation in Applied Chemistry CIQA, the modifications induced by the radiation in formulations with the help of vinyl poly chloride PVC. In these formulations, prepared with cross linking agent, plastifying industrial grade, stuff and non toxic stabilizers of calcium estearate and zinc industrial grade, it is sought to replace the stabilizer of Pb. For this were irradiated it test tubes of PVC with gamma radiation of cobalt 60 to three different dose in atmospheres of air and argon. Later it was determined their thermal stability at different times of heating and it was measured the Young modulus by means of thermo mechanical analysis. Those results obtained together with other techniques of characterization suggest that the irradiated proposed formulation can substitute the one stabilized with lead. (Author)

  9. Preparation and characterization of polymer nanocomposites based on PVDF/PVC doped with graphene nanoparticles

    Directory of Open Access Journals (Sweden)

    I.S. Elashmawi

    Full Text Available Novel nanocomposites based on PVDF/PVC blend containing graphene oxide nanoparticles (GO were prepare using sonicator. IR analysis revealed that the addition of GO prompts a crystal transformation of α-phase of PVDF. The change of the structural before and after adding GO to PVDF/PVC were studied by X-ray diffraction. A decrease in activation energy gap from UV data was observed with increasing GO content, implying a variation of reactivity as a result of reaction extent. The variation of ε′ with frequency is nearly the same as that of ε″. At higher frequencies, the decrease of both ε′ and ε″ becomes nearly constant. The dispersion at lower frequencies ε′ of ε′ polarization is of Maxwell–Wagner interfacial polarization but at higher frequencies, it levels off. The behavior of conductivity (σAC tends to acquire constant values approaching it DC values. The values of σAC was increased after doped GO with exponential increase after the critical value of frequency. All nanocomposites behaved the same fashion revealing that a higher number of polarons were getting added to conducting pool in composites as graphene content was increased. Conduction mechanism appeared to be getting expedited with increasing frequency due to fact that increase in frequency enhances polaron hopping frequency. Keywords: Nanocomposites, Graphene oxide, FT-IR, X-ray, AC conductivity

  10. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic.

    Science.gov (United States)

    Ganjali, Mohammad Reza; Rezapour, Morteza; Pourjavid, Mohammad Reza; Haghgoo, Soheila

    2004-07-01

    N-[2-[4-[[[(Cyclohexylamino)carbonyl]amino]sulfonyl]phenyl]ethyl]-5-methyl pyrazine carboxamide (glipizid) was explored as an electro-active material for preparing a polymeric membrane-based sensor selective to samarium ions. The membrane incorporated 30% poly(vinyl chloride) (PVC), 53% benzyl acetate (BA), 11% glipizid and 6% sodium tetraphenyl borate. When coated on the surface of a graphite electrode, it exhibits Nernstian responses in the concentration range of 1.0 x 10(-5) to 1.0 x 10(-10) M, with a detection limit of 8.0 x 10(-11)M samarium. The electrode shows high selectivity towards samarium over several cations (alkali, alkaline earth, transition and heavy metal ions), and specially lanthanide ions. The proposed sensor has a very short response time (pH range for at least ten weeks. It was used as an indicator electrode in potentiometric titration of Sm(III) ions with an EDTA solution, and for determination of samarium in binary and ternary mixtures.

  11. Study on the effect of stabilizers on discoloring of PVC by irradiation

    International Nuclear Information System (INIS)

    Peng Chaorong; Wang Jingxia; Chen Zhuping; Liu Siyang

    2009-01-01

    Composites of polyvinyl chloride (PVC) filled with stabilizers was irradiated by 60 Co γ-ray. The effect of different stabilizers on the radiation-induced discoloring of PVC was investigated and the structures of irradiated PVC were characterized by ultraviolet spectrum (UV) and Fourrier transfer infrared spectrum (FT-IR). It shows that the stabilizers including calcium stearate/zinc stearate, epoxidised oil, phosphite and photostabilizer can improve the property of resistance to radiation-induced discoloring of PVC, and phosphite can improve the property of resistance to radiation-induced oxidation of PVC. Among the stabilizers, formulations with calcium stearate/zinc stearate show high transparency and excellent property of resistance to radiation at same absorbed dose. Change rate of yellow index of formulation (calcium stearate: zinc stearate=2:1) has been determined to be 8.3% at the absorbed dose of 30 kGy. It has been found that the structures of PVC with numbers of conjugated double bond or α, β-unsaturated ketone are formed after irradiation by γ-rays. (authors)

  12. Studies in cross-linking PVC footwear soling compounds using gamma-irradiation

    International Nuclear Information System (INIS)

    Bloom, L.I.

    1983-01-01

    Irradiation cross-linking of polymeric materials has been known for some time, but it is only in recent years that it has been put to commercial advantage. Well known uses are the modification of PVC for higher temperature applications. Fundamental studies were carried out on amongst other materials, plasticised PVC compounds for use in cable applications. The results of this work, encouraged the author to investigate cross-linkable PVC in areas such as footwear soling

  13. Degradação biológica do PVC em aterro sanitário e avaliação microbiológica Biological degradation of PVC in landfill and microbiological evaluation

    Directory of Open Access Journals (Sweden)

    Ana M. C. Grisa

    2011-01-01

    Full Text Available O poli(cloreto de vinila (PVC é um dos polímeros utilizado no campo das embalagens e no setor calçadista, e, em função da sua aplicação diversificada, apresenta elevados percentuais em aterros domésticos e industriais. É um polímero amorfo podendo apresentar diferentes teores de plastificante e outros aditivos responsáveis pela sua estabilização, os quais podem influenciar no tempo de vida útil e nas propriedades do produto final. Este trabalho apresenta o estudo da degradação química e biológica de filmes de poli(cloreto de vinila flexível (PVC-f, no aterro sanitário São Giácomo, na cidade de Caxias do Sul/RS, antes e após 330 dias de disposição. As amostras de PVC-f antes e após a disposição no aterro sanitário foram avaliadas por análise térmica (TGA, estrutural (FT-IR e morfológica (MEV e MO. Observou-se que as amostras de PVC-f dispostas no aterro sanitário (PVC-fa, apresentam um único evento de perda de massa, em relação ao PVC-f não degradado ou virgem (PVC-fv, além de um maior % de perda de massa e de mudanças estruturais. Nas amostras de PVC-fa foram observadas modificações morfológicas importantes para descrever os fenômenos de degradação como erosão da superfície, bioerosão, que propiciaram a ação das leveduras, bactérias e fungos presentes no meio no polímero aterrado.The poly (vinyl chloride (PVC is one of the polymers used in the field of packing materials and footwear sector, and due its diversified applications, it has presented in a high percentage of domestic and industrial landfills It is an amorphous polymer and may present different levels of plasticizer and other additives responsible for its stabilization, which can influence the lifetime and the properties of the final product. This work presents the study of the chemical and biological degradation of poly (vinyl chloride flexible (PVC-f films, at São Giácomo landfill, in Caxias do Sul city after 330 days of

  14. The development of PVC-laminated steel sheet by an electron beam curing method

    International Nuclear Information System (INIS)

    Masuhara, Ken-ichi; Koshiishi, Kenji; Tomosue, Takao; Mori, Koji; Honma, Nobuyuki

    1988-01-01

    Polyvinyl chloride (PVC) film-laminated steel sheets are used for household electric appliances and building materials. Those are produced usually by pressing a PVC film onto a steel sheet imediately after a themosetting adhesive has been applied to the sheet and curing. However, a major problem of this method is that the appearance of the PVC films such as gloss and embossment changes during pressing due to the heat that is required for causing bonding, therefore, the development of an adhesive which can be cured at lower temperature is necessary. Nisshin Steel Co., Ltd. has developed PVC film-laminated steel sheets for which electron beam (EB) curable adhesives are used to overcome this problem. The advantage of these adhesives is that they can be quickly cured at room temperature. The production procedure of PVC-laminated steel sheets by EB curing is outlined. But this method has encountered two problems: poor adhesion between substrates and adhesive due to the residual stress, and the deterioration of the PVC films due to EB irradiation. EB curable adhesives are mainly composed of acrylic ester oligomers and monomers, and thier adhesion was improved by organic pretreatment. On the other hand, EB-proof PVC films were developed. The general properties of PVC-laminated steel sheets produced by EB curing are reported. (K.I.)

  15. Change Spectroscopic, thermal and mechanical studies of PU/PVC blends

    Energy Technology Data Exchange (ETDEWEB)

    Hezma, A.M. [Spectroscopy Department, Physics Division, National Research Center, Giza (Egypt); Elashmawi, I.S. [Spectroscopy Department, Physics Division, National Research Center, Giza (Egypt); Physic Department, Faculty of Science, Taibah University, Al-Ula (Saudi Arabia); Rajeh, A., E-mail: a.rajeh88@yahoo.com [Physic Department, Faculty of Science, Amran University, Sa' dah (Yemen); Physics Department, Faculty of science, Mansoura University, Mansoura (Egypt); Kamal, Mustafa [Physics Department, Faculty of science, Mansoura University, Mansoura (Egypt)

    2016-08-15

    Blends of polyurethane (PU) and polyvinyl chloride (PVC) with different concentrations were prepared by casting method. The effects of PU on PVC blends was examined by Fourier transform-infrared (FTIR), Ultra-violet visible studies (UV/VIS.), X-ray diffraction (XRD), Thermogravimetric (TGA), Differential scanning calorimetry (DSC), and mechanical properties (stress–strain curve). The interaction between PU and PVC was examined by FT-IR through the absorbance of the N–H groups and was correlated to mechanical/thermal properties. Ultra-violet visible said that optical energy gap decrease with increasing concentration of PU. Differential scanning calorimetry results was observed a single glass transition temperature (T{sub g}) for blends this confirming existence miscibility within the blends. The causes for best thermal stability of some blends may be described by measurements of interactions between C=O groups of PU and the α-hydrogen of PVC or a dipole–dipole –C=O..Cl–C– interactions. Significant alterations in FTIR, X-ray and DSC examination shows an interactions between blends had good miscibility. X-ray shows some alterations in the intensity with additional PU. PU change the mechanical behavior of PVC through of the blends. When polyurethane content increase causes polyvinyl chloride tensile strength decreases and elongation at break increase.

  16. The role of chlorine and additives of PVC-plastic in combustion

    International Nuclear Information System (INIS)

    Mattila, H.

    1991-01-01

    The PVC differs from other common plastics due to the chlorine content. As the PVC is combusted, the chlorine is released mainly as hydrogen chloride. The content of chlorinated hydrocarbons is small, but these can also contain polychlorinated dibenzofuranes and dibenzodioxines, which are extremely poisonous. The aim of this study was to find out, what is the portion of PVC combustion in total emission of chlorinated hydrocarbons. Additionally, the amounts chlorine coming into combustion process with ordinary fuels have been estimated, and they are compared with the amounts of PVC. The chloride content of municipal wastes vary in between 0.4-0.9 %. The portion of plastics is about 30 % of the total, and the rest being from paper, food , wood and garden wastes an textiles. Both organic and inorganic chlorine form gaseous hydrogen chlorid in combustion processes. HCl can then react with oxygen and produce caseous chlorine. This can react with unreacted carbon of the smoke and produce different kinds of chlorinated hydrocarbons. The portion of PVC of the chlorine going into combustion in Finland has been estimated to be about 1-2 %. Combustion tests were made using coal and bark and plastic waste as additional fuel. It was noticed that addition of plastic decreased the amount of polyaromatic hydrocarbons in the smoke. Chlorinated dioxins and furans occurred a little less in the gases of combustion of plastic mixtures not containing PVC than in reference tests, but they increased when PVC containing plastic mixture was combusted, but more chlorinated dioxins and furans were absorbed into fly ash, so the emissions remained almost the same

  17. Effect of complexing salt on conductivity of PVC/PEO polymer blend ...

    Indian Academy of Sciences (India)

    Administrator

    composite polymer, a blend-based polymer electrolyte, composed of two conductive ... LiClO4 electrolytes with various methacrylic and acrylic polymers used as additives .... Z real vs Z imaginary plot for PVC : PEO : LiBF4 at room temperature.

  18. Microsized graphite sensors for potentiometric determination of cyclobenzaprine hydrochloride in pure powder, tablets, and plasma.

    Science.gov (United States)

    Ramadan, Nesrin K; Zaazaa, Hala E; Merey, Hanan A

    2011-01-01

    Two cyclobenzaprine hydrochloride (CZ) microsized graphite selective sensors were investigated with dibutylsebacate as a plasticizer in a polymeric matrix of carboxylated polyvinyl chloride (PVC-COOH) in the case of sensor 1, based on the interaction between the drug and the dissociated COOH groups in the PVC-COOH. Sensor 2 was based on the interaction between the drug and ammonium reineckate, which acted as anionic electroactive material in the presence of polyvinyl chloride matrix. The two sensors were constructed by using 2-hydroxy propyl beta-cyclodextrin as an ionophore, which has a significant influence on increasing the membrane sensitivity and selectivity of both sensors. Fast and stable Nernstian responses of 1 x 10(-5) - 1 x 10(-2) and 1 x 10(-4) - 1 x 10(-2) M for the two sensors, respectively, with slopes of 58.6 and 55.5 mV/decade, respectively, over the pH range 2-4 were obtained. The proposed method displayed useful analytical characteristics for determination of CZ in its pure powder form with average recoveries 99.95 +/- 0.23 and 99.61 +/- 0.34% for sensors 1 and 2, respectively, and in plasma with good recoveries. The sensors were also used to determine the intact drug in the presence of its degradate and, thus, could be used as stability-indicating methods. The obtained results by the proposed methods were statistically analyzed and compared with those obtained by the U.S. Pharmacopeia method; no significant difference for either accuracy or precision was observed. Results obtained with the two electrodes revealed their performance characteristics, which were evaluated according to International Union of Pure and Applied Chemistry recommendations.

  19. Impedance study of the ion-to-electron transduction process for carbon cloth as solid-contact material in potentiometric ion sensors

    International Nuclear Information System (INIS)

    Mattinen, Ulriika; Rabiej, Sylwia; Lewenstam, Andrzej; Bobacka, Johan

    2011-01-01

    Carbon cloth was studied as solid-contact material in potentiometric ion sensors by using electrochemical impedance spectroscopy and potentiometry. The ion-to-electron transduction process was studied by electrochemical impedance spectroscopy by using a two-electrode symmetrical cell where a liquid electrolyte was sandwiched between two solid electrodes, including bare glassy carbon (GC), GC/carbon cloth and GC/poly(3,4-ethylenedioxythiophene). Impedance data for different electrode/electrolyte combinations were evaluated and compared. Solid-contact K + -selective electrodes were fabricated by coating the carbon cloth with a conventional plasticized PVC-based K + -selective membrane via drop casting. These K + -sensors showed proper analytical performance and acceptable long-term potential stability (potential drift ≈ 1 mV/day). Solid contact reference electrodes were fabricated in an analogous manner by coating the carbon cloth with a plasticized PVC membrane containing a moderately lipophilic salt. The results indicate that carbon cloth can be used as a solid-contact material in potentiometric ion sensors and pseudo-reference electrodes.

  20. Thermal stability of formulations of PVC irradiated with γ of 60

    International Nuclear Information System (INIS)

    Martinez P, M.E.; Carrasco A, H.; Castaneda F, A.; Benavides C, R.; Garcia R, S.P.

    2004-01-01

    The industry of cables and wires frequently use cable isolations with base of formulations of PVC, in those that stabilizer has usually been used with the help of heavy metals, as the lead, which is toxic. To solve the problem, from the 2002 one has come studying in combined form in the National Institute of Nuclear Research ININ and the Center of Investigation in Applied Chemistry CIQA, the modifications induced by the radiation in formulations with the help of vinyl poly chloride PVC. In these formulations, prepared with cross linking agent, plastifying industrial grade, stuff and non toxic stabilizers of calcium estearate and zinc industrial grade, it is sought to replace the stabilizer of Pb. For this were irradiated it test tubes of PVC with gamma radiation of cobalt 60 to three different dose in atmospheres of air and argon. Later it was determined their thermal stability at different times of heating and it was measured the Young modulus by means of thermo mechanical analysis. Those results obtained together with other techniques of characterization suggest that the irradiated proposed formulation can substitute the one stabilized with lead. (Author)

  1. Quality control in the recycling stream of PVC from window frames by hyperspectral imaging

    Science.gov (United States)

    Luciani, Valentina; Serranti, Silvia; Bonifazi, Giuseppe; Di Maio, Francesco; Rem, Peter

    2013-05-01

    Polyvinyl chloride (PVC) is one of the most commonly used thermoplastic materials in respect to the worldwide polymer consumption. PVC is mainly used in the building and construction sector, products such as pipes, window frames, cable insulation, floors, coverings, roofing sheets, etc. are realised utilising this material. In recent years, the problem of PVC waste disposal gained increasing importance in the public discussion. The quantity of used PVC items entering the waste stream is gradually increased as progressively greater numbers of PVC products approach to the end of their useful economic lives. The quality of the recycled PVC depends on the characteristics of the recycling process and the quality of the input waste. Not all PVC-containing waste streams have the same economic value. A transparent relation between value and composition is required to decide if the recycling process is cost effective for a particular waste stream. An objective and reliable quality control technique is needed in the recycling industry for the monitoring of both recycled flow streams and final products in the plant. In this work hyperspectral imaging technique in the near infrared (NIR) range (1000-1700 nm) was applied to identify unwanted plastic contaminants and rubber present in PVC coming from windows frame waste in order to assess a quality control procedure during its recycling process. Results showed as PVC, PE and rubber can be identified adopting the NIR-HSI approach.

  2. Structural, optical and thermal characterization of PVC/SnO2 nanocomposites

    Science.gov (United States)

    Taha, T. A.; Ismail, Z.; Elhawary, M. M.

    2018-04-01

    The structural, optical, and thermal properties of PVC/SnO2 nanocomposites were investigated. XRD patterns were used to explore the structures of these prepared samples. Optical UV-Vis measurements were analyzed to calculate the spectroscopic optical constants of the prepared PVC/SnO2 nanocomposites. Both direct and indirect optical band gaps decreased with increasing SnO2 content. The refractive index, high frequency dielectric constant, plasma frequency, and optical conductivity values increased with SnO2. The single oscillator energy increased from 5.64 to 10.97 eV and the dispersion energy increased from 6.35 to 19.80 eV with the addition of SnO2. The other optical parameters such as optical moments, single oscillator strength, volume energy loss, and surface energy loss were calculated for different SnO2 concentrations. Raman spectra of the PVC/SnO2 nanocomposite films revealed the characteristic vibrational modes of PVC and surface phonon modes of SnO2. The thermal stability of PVC/SnO2 nanocomposite films was studied using DTA and thermogravimetric analysis. The glass transition ( T g) values abruptly changed from 46 °C for PVC to an average value of 59 °C for the polymer films doped with 2.0, 4.0, and 6.0 wt% SnO2. The weight loss decreased as the SnO2 concentration increased in the temperature range of 350-500 °C, corresponding to enhanced thermal stability.

  3. PVC-based synthetic leather to provide more comfortable and sustainable vehicles

    Science.gov (United States)

    Maia, I.; Santos, J.; Abreu, MJ; Miranda, T.; Carneiro, N.; Soares, GMB

    2017-10-01

    Consumers are increasingly demanding the interior of cars to be comfortable even in the case of more economic commercial segments. Thus, the development of materials with thermoregulation properties has assumed renewed interest for these particular applications. An attempt has been made to prepare a multilayer PVC-based synthetic leather with paraffinic PCMs to be applied on a car seat. The thermal behaviour of the material was analysed using Alambeta apparatus, a thermo-camera and a thermal manikin. The results obtained show that the synthetic leather with incorporated PCMs gives cooler feeling and has higher reaction times regarding environmental temperature variations than the material without PCMs incorporation. Globally, the new designed material allowed greater thermal comfort to the cars´ inhabitants. In addition, the material quality was evaluated according to the standard of the customer, BMW 9,210,275; Edition / Version 4, 2010-10-01 revealing that the material meets all the requirements under test, except for the performance in terms of flexibility.

  4. Estado de mistura e dispersão da fase borrachosa em blendas PVC/NBR Phase separation and rubber phase dispersion in PVC/NBR blends

    Directory of Open Access Journals (Sweden)

    Fábio R. Passador

    2006-01-01

    Full Text Available Termoplásticos modificados com elastômeros têm despertado grande interesse de pesquisadores e de indústrias devido à atraente relação custo/benefício e a possibilidade de aumento significativo da tenacidade sob impacto de polímeros frágeis com a incorporação de uma fase borrachosa dispersa. Este artigo mostra a relação entre o estado de mistura e a dispersão da fase borrachosa em blendas de poli (cloreto de vinila (PVC com borracha nitrílica (NBR. O estado de mistura de blendas poliméricas é um fator muito importante a ser considerado no desenvolvimento destes tipos de materiais, uma vez que determina o nível de mistura molecular das blendas. A característica estrutural do PVC é responsável pela morfologia das blendas PVC/NBR, sendo que há uma otimização de propriedades mecânicas quando as partículas de borracha formam a morfologia "pseudo-network", ou seja, quando as partículas de borracha estão randomicamente dispersas entre as partículas primárias do PVC.Thermoplastics modified with elastomers have attracted great interest of researchers and industries due to the low cost/benefit relationship and the possibility of significant increase in the toughness of brittle polymers through the incorporation of a dispersed rubber phase. This article shows the relationship between the interaction between phases and rubber phase dispersion in poly (vinyl chloride/nitrile rubber blends. The interaction between components in polymer blends is an important factor to be considered in the development of this kind of materials because it determines the level of the mixture at the molecular level. The particulate nature of PVC and the degree of nitrile groups in the NBR are responsible to the PVC/NBR blends morphologies leading to an optimization of the mechanical properties when the rubber particles form a pseudo-network morphology with the rubber particles randomly dispersed in between the PVC primary particles.

  5. Bedside identification of patients at risk for PVC-induced cardiomyopathy: Is ECG useful?

    Science.gov (United States)

    Garster, Noelle C; Henrikson, Charles A

    2017-07-01

    Premature ventricular complexes (PVCs) are an underrecognized cause of cardiomyopathy. Standard 12-lead electrocardiogram (ECG) has potential to direct attention toward at-risk patients. We performed a single-center, retrospective chart review of 1,240 patients who completed ECG and Holter monitoring at Oregon Health and Science University Hospital between January 1, 2011 and December 31, 2013 to investigate the relationship of PVC frequency on ECG with burden on Holter. Primary outcome measures included PVC quantity on ECG, mean PVC quantity on Holter, and percentage of total beats on Holter recorded as PVCs. High PVC burden was defined as ≥10% of total beats. Weighted mean percentages of total beats on Holter monitor recorded as PVCs were calculated for 0, 1, 2, and ≥3 PVCs on ECG and found to be 1.4% (n = 1,128), 3.5% (n = 32), 4.3% (n = 25), and 16.6% (n = 55), respectively, which represent statistically significant differences (P ECG for ≥10% PVC Holter burden was 58%. Negative predictive value for 0 PVCs on ECG was 98%. The sensitivity and specificity of ECG to identify high PVC burden on Holter was 72% and 93.6%, respectively, when utilizing a positive ECG result as one PVC or more, and 44% and 98.9%, respectively, with ≥3 PVCs on ECG. The positive likelihood ratio corresponding to ≥3 PVCs on ECG was 40. These findings demonstrate that the number of PVCs on ECG can be utilized for quick bedside estimation of high PVC burden. © 2017 Wiley Periodicals, Inc.

  6. The Paradigms They Are a-Changin': past, present and future of PVC bacteria research.

    Science.gov (United States)

    Rivas-Marín, Elena; Devos, Damien P

    2018-06-01

    These are exciting times for PVC researchers! The PVC superphylum is composed of the bacterial phyla Planctomycetes, Verrucomicrobia, Chlamydiae (those three founders giving it its name), Lentisphaerae and Kirimatiellaeota as well as some uncultured candidate phyla, such as the Candidatus Omnitrophica (previously known as OP3). Despite early debates, most of the disagreements that surround this group of bacteria have been recently resolved. In this article, we review the history of the study of PVC bacteria, with a particular focus on the misinterpretations that emerged early in the field and their resolution. We begin with a historical perspective that describes the relevant facts of PVC research from the early times when they were not yet termed PVC. Those were controversial times and we refer to them as the "discovery age" of the field. We continue by describing new discoveries due to novel techniques and data that combined with the reinterpretations of old ones have contributed to solve most of the discordances and we refer to these times as the "illumination age" of PVC research. We follow by arguing that we are just entering the "golden age" of PVC research and that the future of this growing community is looking bright. We finish by suggesting a few of the directions that PVC researches might take in the future.

  7. Potentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors.

    Science.gov (United States)

    Hefnawy, Mohammed M; Homoda, Atef M; Abounassif, Mohammed A; Alanazi, Amer M; Al-Majed, Abdulrahaman; Mostafa, Gamal A

    2014-01-01

    The construction and electrochemical response characteristics of Poly (vinyl chloride) membrane sensors for moxifloxacin HCl (MOX) are described. The sensing membranes incorporate ion association complexes of moxifloxacin cation and sodium tetraphenyl borate (NaTPB) (sensor 1), phosphomolybdic acid (PMA) (sensor 2) or phosphotungstic acid (PTA) (sensor 3) as electroactive materials. The sensors display a fast, stable and near-Nernstian response over a relative wide moxifloxacin concentration range (1 × 10(-2) - 4.0 × 10(-6), 1 × 10(-2) - 5.0 × 10(-6), 1 × 10(-2) - 5.0 × 10(-6) M), with detection limits of 3 × 10(-6), 4 × 10(-6) and 4.0 × 10(-6) M for sensor 1, 2 and 3, respectively over a pH range of 6.0 - 9.0. The sensors show good discrimination of moxifloxacin from several inorganic and organic compounds. The direct determination of 400 μg/ml of moxifloxacin show an average recovery of 98.5, 99.1 and 98.6% and a mean relative standard deviation of 1.8, 1.6 and 1.8% for sensors 1, 2 and 3 respectively. The proposed sensors have been applied for direct determination of moxifloxacin in some pharmaceutical preparations. The results obtained by determination of moxifloxacin in tablets using the proposed sensors are comparable favorably with those obtained using the US Pharmacopeia method. The sensors have been used as indicator electrodes for potentiometric titration of moxifloxacin.

  8. Physicomechanical properties of PVC radiation-modified by tridecaethyleneglycol methacrylic ester

    International Nuclear Information System (INIS)

    Lomonosova, N.V.

    1988-01-01

    A study was made on physicomechanical properties of radiation-modified system on the basis of PVC and TGM-13 oligomer (dimethacrylic ester of tridecaethyleneglycol, 43.2%). Main physical properties of the composition (maximal stresses, softening point, double refraction value, activation energy, temperature positions of the first and the second maximums on isometric heating diagram) were used to determine its isotropic and oriented states, depending on absorbed radiation dose (0-128 kGy). It is shown that radiation PVC modification by TGM-13 oligomer results in formation of linked 'soft' plastic. In terms of strength it is on a par with isotropic linear PVC, but compare favourably with it with respect to t ρ and ε

  9. Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure - Dimensions of sockets - Metric series

    CERN Document Server

    International Organization for Standardization. Geneva

    1985-01-01

    Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure - Dimensions of sockets - Metric series

  10. Investigation of Ice-PVC separation under Flexural Loading using FEM Analysis

    Directory of Open Access Journals (Sweden)

    H Xue

    2016-08-01

    Full Text Available This paper presents the FEM technique applied in the study of ice separation over a polyvinyl chloride (PVC surface. A two layer model of ice and PVC is analysed theoretically using Euler-Bernoulli beam theory and the rule of mixtures. The physical samples are prepared by freezing ice over the PVC surfaces. The samples are tested experimentally in a four-point loading setup. The experimental results contain strain data gathered through a data acquisition system using the LabView software. The data is collected at the rate of 1 kHz per load step. A model is also coded in MATLAB® and simulated using the finite element method (FEM in ANSYS® Multiphysics. The FEM model of the ice and PVC sample is built using solid elements. The mesh is tested for sensitively. A good agreement is found between the theoretical, experimental and numerical simulation results.

  11. A Laboratory Experimental Study: An FBG-PVC Tube Integrated Device for Monitoring the Slip Surface of Landslides

    Science.gov (United States)

    Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao

    2017-01-01

    A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157

  12. Functionalization of PVC membrane with ss oligonucleotides for a potentiometric biosensor.

    Science.gov (United States)

    Shishkanova, T V; Volf, R; Krondak, M; Král, V

    2007-05-15

    A novel application of a single stranded (ss) oligonucleotide as an active component of polymeric membrane in an ion-selective electrode (ISE) is described. The original oligonucleotides, oligo(dA)(15), modified by cholesterol, triphenylmethyl and hexadecyl derivatives, were immobilized into poly(vinyl chloride) (PVC) membrane using extraction protocol. In parallel, the adsorption protocol was used to immobilize unmodified oligo(dA)(15) on the PVC membrane based on tridodecylmethyammonium chloride (TDDMA(+)Cl(-)). Immobilization of ss oligonucleotide probe through spacer was more effective for the potentiometric detection of the hybridization between complementary oligonucleotides. It was found that cholesterol-oligo(dA)(15) modified membranes were sensitive toward complementary oligo(dT)(15) in the concentration range 2-80 nM at pH 7. An explanation for the detection mechanism is proposed.

  13. Estudo do comportamento de compostos de PVC com adição de amido Study of the behavior of PVC compounds with added starch

    Directory of Open Access Journals (Sweden)

    Lisandra Abatti

    2011-01-01

    Full Text Available Este trabalho apresenta o estudo do comportamento de compostos de PVC com adição de amido para aplicação especialmente na indústria calçadista. As propriedades mecânicas dos compostos nas proporções de 5, 7,5 e 10% foram estudadas através de ensaios de tração. Também foram verificados os índices de fluidez, alterações de propriedades quando submetidos ao envelhecimento artificial em estufa e natural ao expor às intempéries e enterrar no solo. A viabilidade da aplicação na indústria calçadista foi feita por injeção em gáspeas e tiras de sandálias, com testes de resistência, flexão e testes de campo. Os resultados demonstraram que o acréscimo de amido ao PVC provoca perda nas propriedades mecânicas, justificado pela baixa resistência mecânica do amido em relação ao PVC. Após envelhecimento em estufa o processo de retrogradação do amido deixa os compostos mais rígidos e com menor fluidez. Quando expostos às intempéries e ao solo, o PVC pode ser degradado com perda de HCl, o que leva à acidificação do solo. Nas aplicações em calçados e sandálias a resistência mecânica não atende aos requisitos do mercado. Apesar do baixo custo, o fraco comportamento mecânico dificulta sua viabilização para substituição em escala.This paper deals with the behavior of PVC compounds with addition of starch for applications, especially in the footwear industry. The mechanical properties of the compounds in the proportions of 5, 7.5 and 10% were studied using tensile tests. Also investigated were the flow rates, in addition to changes in properties when the material was subjected to artificial aging in an oven and exposed to natural weather and buried in the soil. The feasibility of application in the industry was evaluated with tests of endurance, strength and field tests in injection uppers and straps of sandals. The results showed that the addition of starch to PVC causes loss of mechanical properties, owing to

  14. Radiation effect on PVC/ENR blends

    International Nuclear Information System (INIS)

    Chantara Thevy Ratnam; Khairul Zaman Mohd Dahlan

    1997-01-01

    The effect of irradiation on the physical properties of Polyvinyl Chloride / Epoxidised Natural Rubber Blends (PVC/ENR blends) were investigated. The enhancement in tensile strength, elongation at break, hardness and aging properties of the blends have confirmed the positive effect of irradiation on the blends. It is evident from gel fraction and infra red spectroscopic studies that the blends of PVC and ENR cross-linked upon irradiation. The results also revealed that at any blend composition, the enhancement in properties depend on irradiation dose which controls the degree of radiation induced cross-linking. In an attempt to maximize the constructive effect of irradiation, the influence of various additives such as stabilizers, radiation sensitizers, fillers and processing aids on the blend properties were studied. The changes in blend properties upon irradiation with the presents of above additives were also presented in this paper

  15. Thermal and catalytic decomposition behavior of PVC mixed plastic waste with petroleum residue

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Mohammad Farhat; Siddiqui, Mohammad Nahid [Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-08-15

    The pyrolysis and hydropyrolysis of PVC mixed plastic waste alone and with petroleum residue was carried out at 150 and 350{sup o}C under N{sub 2} gas and at 430{sup o}C under 6.5MPa H{sub 2} gas pressure. The behavior of plastic waste during thermal and catalytic decomposition has also been studied in single- and two-stage reaction processes. In the individual pyrolysis process, both the petroleum residue and polystyrene (PS) undergo more than 90% conversion to liquid and gaseous products, whereas low-density polyethylene (LDPE) and high-density polyethylene (HDPE) yielded lower conversions products, and polypropylene (PP) and polyvinyl chloride (PVC) afforded somewhere a moderate to high conversion products. In a single-stage pyrolysis reaction, PVC was processed with petroleum residue at 150 and 430{sup o}C, under N{sub 2} gas for 1h at each temperature in a glass reactor. The model PVC and waste PVC showed slight variations in the products distribution obtained from the glass reactor. In two-stage process, model PVC, vacuum gas oil (VGO) and a number of different catalysts were used in a stainless steel autoclave micro tubular reactor at 350{sup o}C under the stream of N{sub 2} gas for 1h and at 430{sup o}C under 950psi (6.5MPa) H{sub 2} pressure for the duration of 2h. Significantly, different products distributions were obtained. Among the catalysts used, fluid catalytic cracking (FCC) and hydrocracking catalysts (HC-1) were most effective in producing liquid fuel (hexane soluble) materials. The study shows that the catalytic coprocessing of PVC with VGO is a feasible process by which PVC and VGO materials can be converted into transportation fuels.

  16. Combinatorial screening of potentiometric Pb(II) sensors from polysulfoaminoanthraquinone solid ionophore.

    Science.gov (United States)

    Huang, Mei-Rong; Ding, Yong-Bo; Li, Xin-Gui

    2014-03-10

    A potentiometric Pb(II)-selective sensor was fabricated by a combinatorial screening of electrically conducting polysulfoaminoanthraquinone (PSA) nanoparticles as a solid ionophore, ion exchangers (oleic acid (OA) and NaTPB), plasticizers in a polyvinyl chloride (PVC) matrix, membrane thickness, inner filling ion species, and concentration. The membrane sensor with the composition of PSA/PVC/DOP (dioctyl phthalate)/OA (1.0:33:61:5.0) exhibited the best performance, including a slope of 29.3 mV decade(-1) in the concentration range 10(-6.3)-10(-1.6) M, detection limit of 1.6 × 10(-7) M, response time of 16 s, lifetime of five months, and good response reversibility. The proposed sensor has demonstrated good selectivity for Pb(II) over other monovalent, divalent and trivalent interfering ions, and could be used in a pH range of 3.62-5.22. The Pb(II) sensor has been successfully applied for the determination of Pb(II) concentration in real-world samples and also as an indicator electrode for potentiometric titration of lead ions.

  17. Effect of oil extracted from coffee grounds in the radiolytic stabilization of PVC

    International Nuclear Information System (INIS)

    Lima, Thaysa Araujo de; Aquino, Katia Aparecida da Silva; Araujo, Elmo S.

    2013-01-01

    Commercial Poly(vinyl chloride) (PVC) containing oil extracted from coffee grounds (OCG) at concentrations of 0.50; 1.00 and 1.50 wt% were investigated. The samples were irradiated with gamma radiation ( 60 Co) at room temperature and air atmosphere. The viscosity-average molar mass (M v ) was measured for PVC systems without and with oil. Decreases in molar mass observed when the systems were gamma irradiated reflect the random scission effects that take place in the main chain. Degradation index (DI) value was also obtained by viscosity analysis. DI results showed that the addition of OCG at 0.5 wt% into PVC matrix irradiated at dose of 25 kGy decreased the number of main chain scissions and was calculated a protection index of 67% in PVC matrix. Results about the free radical scavenger action of the OCG were obtained by use of 2,2-diphenyl-1-(2,4,6-trinitrophenyl)-hydrazyl radical (DPPH) and are discussed in this study. Decrease of 7% of Young's modulus value and a decrease of 31.5% on the elongation at break value were recorded for PVC films exposed to gamma irradiation. However, no significant changes were recorded in mechanical properties of PVC with OCG. (author)

  18. Effect of oil extracted from coffee grounds in the radiolytic stabilization of PVC

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Thaysa Araujo de; Aquino, Katia Aparecida da Silva; Araujo, Elmo S., E-mail: aquino@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2013-07-01

    Commercial Poly(vinyl chloride) (PVC) containing oil extracted from coffee grounds (OCG) at concentrations of 0.50; 1.00 and 1.50 wt% were investigated. The samples were irradiated with gamma radiation ({sup 60}Co) at room temperature and air atmosphere. The viscosity-average molar mass (M{sub v}) was measured for PVC systems without and with oil. Decreases in molar mass observed when the systems were gamma irradiated reflect the random scission effects that take place in the main chain. Degradation index (DI) value was also obtained by viscosity analysis. DI results showed that the addition of OCG at 0.5 wt% into PVC matrix irradiated at dose of 25 kGy decreased the number of main chain scissions and was calculated a protection index of 67% in PVC matrix. Results about the free radical scavenger action of the OCG were obtained by use of 2,2-diphenyl-1-(2,4,6-trinitrophenyl)-hydrazyl radical (DPPH) and are discussed in this study. Decrease of 7% of Young's modulus value and a decrease of 31.5% on the elongation at break value were recorded for PVC films exposed to gamma irradiation. However, no significant changes were recorded in mechanical properties of PVC with OCG. (author)

  19. A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Mohammad Nooredeen; Hend Samy Amer [National Research Centre, Cairo (Egypt)

    2013-04-15

    A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from 3 Χ 10{sup -7} to 1 Χ 10{sup -2} M and a lower detection limit (LDL) of 1 Χ 10{sup -7} M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.

  20. Penelitian pengaruh asam sulfat terhadap sifat fisika kekerasan atasan sepatu kerja PVC

    Directory of Open Access Journals (Sweden)

    Kusumo Retno Winahyu

    1996-12-01

    Full Text Available The Research of hardness aspect of PVC boot upper treated by sulfuric acid to detect influence of sulfuric acid to hardness upper on PVC boot upper. The method of the research has been done by immersing samples in sulfuric acid solution 30 % (v/v for 24 hours. After immersing samples examined connected with hardness physical property. The result of the research shown that hardness physical property become decreasing until 16,08 % has error standard 5,48. It is still agree with SNI 12 – 1848-1990. Sepatu bot dari PVC.

  1. Thermal stabilisation of pvc with jatropha seed, khaya seed and rubber seed oils. Effect of barium and cadmium soaps of the seed oils on the thermal degradation of pvc

    International Nuclear Information System (INIS)

    Okieimen, F.E.

    2003-01-01

    Polyvinyl chloride was mixed with barium and cadmium soaps of Jatropha seed, Khaya seed and rubber seed oils and mixtures of the metal soaps and degraded at 190 deg. C under oxidative and non oxidative conditions. The effectiveness of the additives in stabilizing PVC against thermal degradation was evaluated by comparing (a) the kinetic data measured at 1% conversion for the degradation of PVC in the presence of the additives with the corresponding values obtained in the absence of the additives (b) the intrinsic viscosity and level of unsaturation in the polymer samples degraded for the under graded polymer and (c) the thermogravimetric data obtained for the degradation of PVC in the presence of the additives at a constant heating rate of 10 degree C min/sup -1/ up to 500 degree C. It was found that the additives retarded the rate of dehydro chlorination of PVC (by up to about 50% and 1% conversion) and reduced the extent of decomposition of the polymer by as much as 60%. The mixtures of the metal soaps containing more than 70% (wt) cadmium soap showed marked synergistic stabilizing effect on the degradation of PVC. (author)

  2. Evaluation of the influence of water and oil derivatives absorption on PVC pipes; Avaliacao da influencia da absorcao de agua e de derivados de petroleo em tubulacoes de PVC

    Energy Technology Data Exchange (ETDEWEB)

    Carpio, D.C.F. del; D' Almeida, J.R.M., E-mail: dalmeida@puc-rio.b [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    PVC is the only polymer of large consume that is not totally obtained from petroleum, since it contains 57% of chlorine. As chlorine containing materials are resistant to bacteria rich environments, such as buried pipes, PVC is being used for fluid transportation, principally water, but it can also be considered as an alternative material for the transportation of other fluids. This work analyzes the aging behavior of PVC exposed to water, ethanol and diesel oil, using TGA, DSC, FT-IR and DR-X techniques. The results showed that the chemical structure of PVC is not affected by exposure to water and ethanol. For these fluids a dipolar interaction could be occurring, increasing at the beginning of the absorption process, the polymer thermal stability. The diesel oil caused plasticization, with reduction of the Tg since the beginning of the aging process. (author)

  3. Penelitian penggunaan minarex sebagai plasticizer untuk pembuatan kompon slang PVC

    Directory of Open Access Journals (Sweden)

    Niken Karsiati

    1995-12-01

    Full Text Available The objective of the research is to find out the maximum quantity of Minarex as plasticizer which can be added in making compound PVC hose which fulfills the requirements of JIS K. 6771-77 “Flexible Vinyl Tube. Materials used are PVC resin added by additives, i.e DOP, BaCdZn, Stearic Acid, dyes and Minarex as DOP substitution. They all must be mixed and feed to two roll mill homogenizing. Temperature of operational is within 50-800C, roll speed is approximately 10 and 8,6 rpm. Then the compound is moulded into slab form using hydraulic press machine at 1700C, pressure 150 kg/cm2for 10 minutes. The slab is tested its physical properties including tensile strength, elongation at break, tensile strength after accelerated aging, and also observed organoleptically. Based on the research, compound with Minarex substitution 10 parts still conform to JIS K. 6771-77 and the appearance is good.

  4. High performance flexible pH sensor based on carboxyl-functionalized and DEP aligned SWNTs

    International Nuclear Information System (INIS)

    Liu, Lu; Shao, Jinyou; Li, Xiangming; Zhao, Qiang; Nie, Bangbang; Xu, Chuan; Ding, Haitao

    2016-01-01

    Highlights: • The flexible chemiresistive pH sensor based on two-terminal microsensors eliminating the need for a reference electrode, is simple in structure and can be fabricated on a variety of substrates such as PET, PI and PVC. • SWNTs as an ideal one dimensional material are carboxyl-functionalized to make the pH sensor show high sensitivity and outstanding flexibility for practical applications. • DEP technique is used to manipulate and position SWNTs into appropriate locations and desired formations to improve the metal-nanotube interface and highly rapid detection of pH value, resulting in better overall device performance. • Mechanical bendability of the pH sensor, which arises from the combination of flexible PET substrates and SWNTs, offer a significant improvement for applications that are difficult or impossible to achieve with traditional sensors on rigid substrates. - Abstract: The detection and control of the pH is very important in many biomedical and chemical reaction processes. A miniaturized flexible pH sensor that is light weight, robust, and conformable is very important in many applications, such as multifunctional lab-on-a-chip systems or wearable biomedical devices. In this work, we demonstrate a flexible chemiresistive pH sensor based on dielectrophoresis (DEP) aligned carboxyl-functionalized single-walled carbon nanotubes (SWNTs). Decorated carboxyl groups can react with hydrogen (H"+) and hydroxide (OH"−) ions, enabling the sensor to be capable of sensing the pH. DEP is used to deposit well-organized and highly aligned SWNTs in desired locations, which improves the metal-nanotube interface and highly rapid detection of the pH, resulting in better overall device performance. When pH buffer solutions are dropped onto such SWNTs, the H"+ and OH"− ions caninteract with the carboxyl groups and affect the generation of holes and electrons in the SWNTs, leading to resistance variations in the SWNTs. The results shows that the

  5. High performance flexible pH sensor based on carboxyl-functionalized and DEP aligned SWNTs

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Lu; Shao, Jinyou, E-mail: jyshao@mail.xjtu.edu.cn; Li, Xiangming; Zhao, Qiang; Nie, Bangbang; Xu, Chuan; Ding, Haitao

    2016-11-15

    Highlights: • The flexible chemiresistive pH sensor based on two-terminal microsensors eliminating the need for a reference electrode, is simple in structure and can be fabricated on a variety of substrates such as PET, PI and PVC. • SWNTs as an ideal one dimensional material are carboxyl-functionalized to make the pH sensor show high sensitivity and outstanding flexibility for practical applications. • DEP technique is used to manipulate and position SWNTs into appropriate locations and desired formations to improve the metal-nanotube interface and highly rapid detection of pH value, resulting in better overall device performance. • Mechanical bendability of the pH sensor, which arises from the combination of flexible PET substrates and SWNTs, offer a significant improvement for applications that are difficult or impossible to achieve with traditional sensors on rigid substrates. - Abstract: The detection and control of the pH is very important in many biomedical and chemical reaction processes. A miniaturized flexible pH sensor that is light weight, robust, and conformable is very important in many applications, such as multifunctional lab-on-a-chip systems or wearable biomedical devices. In this work, we demonstrate a flexible chemiresistive pH sensor based on dielectrophoresis (DEP) aligned carboxyl-functionalized single-walled carbon nanotubes (SWNTs). Decorated carboxyl groups can react with hydrogen (H{sup +}) and hydroxide (OH{sup −}) ions, enabling the sensor to be capable of sensing the pH. DEP is used to deposit well-organized and highly aligned SWNTs in desired locations, which improves the metal-nanotube interface and highly rapid detection of the pH, resulting in better overall device performance. When pH buffer solutions are dropped onto such SWNTs, the H{sup +} and OH{sup −} ions caninteract with the carboxyl groups and affect the generation of holes and electrons in the SWNTs, leading to resistance variations in the SWNTs. The results

  6. Plastics piping systems for industrial applications : acrylonitrile-butadiene- styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) : specifications for components and the system : metric series

    CERN Document Server

    International Organization for Standardization. Geneva

    2003-01-01

    Plastics piping systems for industrial applications : acrylonitrile-butadiene- styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) : specifications for components and the system : metric series

  7. PAN-Immobilized PVC-NPOE Membrane for Environmentally Friendly Sensing of Cd(II Ions

    Directory of Open Access Journals (Sweden)

    Moersilah Moersilah

    2017-04-01

    Full Text Available A simple, cheap and environmentally friendly analytical method of Cd(II in the aqueous system has been developed by immobilization of 1-(2-pyridilazo-2-naphtol (PAN in poly vinyl chloride (PVC matrix and nitrophenyl octyl ether (NPOE as a plasticizer. Upon contact with Cd(II in solution, the color of sensor membrane changes from dark yellow to dark red, which is due to the formation of Cd(II–PAN complex. The best sensing results were obtained at pH 8.0 and λmax 558 nm. The dimension of the proposed sensor membrane was 0.8 cm x 2 cm with a thickness of 0.05 mm, the volume of sample was 2 mL with the Cd(II concentration range of  0 – 1.2 ppm. The limit of detection of the method was found to be 0.432 + 0.104 ppm, which was reversible. The proposed methods have been applied in the determination of Cd(II in water samples after addition of internal standard.

  8. Preparation of modified clay with benzethonium or cetylpyridinium chloride and evaluation of their interactions with PVC

    International Nuclear Information System (INIS)

    Resende, Daniel K.; Dornelas, Camila B.; Moreira, Leonardo A.; Gomes, Ailton S.; Tavares, Maria I.B.; Cabral, Lucio M.; Simeoni, Luiz A.

    2009-01-01

    The objective of this work was the preparation of modified clays with benzethonium or cetylpyridinium to obtain organophilic silicates with good stability and evaluate the possible use of them for the preparation of nanocomposites of poly(vinyl chloride) (PVC). The reactions of modification of clays and the PVC were prepared by solution intercalation. The new clays were evaluated by X-ray diffraction (XRD) and Low field nuclear magnetic resonance (NMR). The reactions of clays with PVC were assessed by Low-field NMR, through the determination of proton spin lattice relaxation time. The stability of new organophilic clays and their reactions with PVC were evaluated by thermogravimetric analysis (TGA). High stability was observed for organophilic clays prepared. The degradation of PVC materials obtained with the organophilic clay began at temperatures above 200 deg C. If it is considered that the temperatures normally used in the processing of PVC are between 140 deg C to 180 deg C, the observed results may indicate the possibility of the use of clays for preparation of nanomaterials with PVC. (author)

  9. Estimation of life of PVC cables

    International Nuclear Information System (INIS)

    Bora, J.S.; Babar, A.K.

    1989-01-01

    Life-spans at various extrapolated temperatures corresponding to early, mid and late-stage failures of PVC are quite consistent and is about 32 years at 30degC. For every 10degC rise in ambient temperature life becomes less than half. (author). 2 tabs

  10. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands.

    Science.gov (United States)

    Singh, Ashok K; Singh, Prerna; Banerjee, Shibdas; Mehtab, Sameena

    2009-02-02

    The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetramethylacrylate-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-di ene (L(1)) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L(2)) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L(1): PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L(1) was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb(3+) ions with limits of detection of 3.4 x 10(-8)mol L(-1) for PME and 5.7 x 10(-9)mol L(-1) for CGE. The response time for PME and CGE was found to be 10s and 8s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb(3+) ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb(3+) ions in tap water and various binary mixtures with quantitative results.

  11. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Ashok K. [Department of Chemistry, Indian Institute of Technology-Roorkee, Roorkee 247 667 (India)], E-mail: akscyfcy@iitr.ernet.in; Singh, Prerna; Banerjee, Shibdas; Mehtab, Sameena [Department of Chemistry, Indian Institute of Technology-Roorkee, Roorkee 247 667 (India)

    2009-02-02

    The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11, 15-tetramethyl-1,7,10,16-tetramethylacrylate -1,4,7,10,13, 16-hexaazacyclooctadeca-3,13-di ene (L{sub 1}) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L{sub 2}) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L{sub 1}: PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L{sub 1} was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb{sup 3+} ions with limits of detection of 3.4 x 10{sup -8} mol L{sup -1} for PME and 5.7 x 10{sup -9} mol L{sup -1} for CGE. The response time for PME and CGE was found to be 10 s and 8 s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb{sup 3+} ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb{sup 3+} ions in tap water and various binary mixtures with quantitative results.

  12. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands

    International Nuclear Information System (INIS)

    Singh, Ashok K.; Singh, Prerna; Banerjee, Shibdas; Mehtab, Sameena

    2009-01-01

    The two macrocyclic pendant ligands 3,4,5:12,13,14-dipyridine-2,6,11, 15-tetramethyl-1,7,10,16-tetramethylacrylate -1,4,7,10,13, 16-hexaazacyclooctadeca-3,13-di ene (L 1 ) and 3,4,5:12,13,14-dipyridine-2,6,11,15-tetramethyl-1,7,10,16-tetra(2-cyano ethane)-1,4,7,10,13,16-hexaazacyclooctadeca-3,13-diene (L 2 ) have been synthesized and explored as neutral ionophores for preparing poly(vinylchloride) (PVC) based membrane sensors selective to Tb(III) ions. Effects of various plasticizers and anion excluders were studied in detail and improved performance was observed. The best performance was obtained for the membrane sensor having a composition of L 1 : PVC:1-CN:NaTPB in the ratio of 6: 32: 58: 4 (w/w; mg). The performance of the membrane based on L 1 was compared with polymeric membrane electrode (PME) as well as with coated graphite electrode (CGE). The electrodes exhibit Nernstian slope for Tb 3+ ions with limits of detection of 3.4 x 10 -8 mol L -1 for PME and 5.7 x 10 -9 mol L -1 for CGE. The response time for PME and CGE was found to be 10 s and 8 s, respectively. The potentiometric responses are independent of the pH of the test solution in the pH range 3.0-7.5 for PME and 2.0-8.5 for CGE. The CGE has found to work satisfactorily in partially non-aqueous media upto 30% (v/v) content of methanol, ethanol and 20% (v/v) content of acetonitrile and could be used for a period of 5 months. The CGE was used as indicator electrode in the potentiometric titration of Tb 3+ ions with EDTA and in determination of fluoride ions in various samples. It can also be used in direct determination of Tb 3+ ions in tap water and various binary mixtures with quantitative results

  13. Migration of additives from poly(vinyl chloride) (PVC) tubes into aqueous media

    DEFF Research Database (Denmark)

    Wang, Qian; Storm, Birgit Kjærside

    2005-01-01

    The stability and migration product of medical PVC tubes plasticized with polyadipates were investigated by ageing in phosphate buffer at pH 1.679 and water at different temperatures. Changes in the PVC tubes were studied by wtaer absorption, weight loss, Fourier infrared spectroscopy (FTIR.......5% and only a small amount of adipic acid migrated when a tube was aged at 37 C in water and phosphate buffer (pH 1.679), and at 70 C in water after 56 days. However, when aged at 70 and 110 C, gradual deactivation of heat stabilizer after 21 days of ageing in buffer solution and separation of plasticizer...... from PVC matrix occurred. When the tube was aged at 110 C, significant degradation of both polyadipates and PVC were observed. Adipic acid and 1,4-butanediol monomers and oligomers of polyadipate were the major migration products from polyadipates in the water ageing solution, while only a relatively...

  14. Cell Adhesion to Plasma-Coated PVC

    Directory of Open Access Journals (Sweden)

    Elidiane C. Rangel

    2014-01-01

    Full Text Available To produce environments suitable for cell culture, thin polymer films were deposited onto commercial PVC plates from radiofrequency acetylene-argon plasmas. The proportion of argon in the plasmas, PAr, was varied from 5.3 to 65.8%. The adhesion and growth of Vero cells on the coated surfaces were examined for different incubation times. Cytotoxicity tests were performed using spectroscopic methods. Carbon, O, and N were detected in all the samples using XPS. Roughness remained almost unchanged in the samples prepared with 5.3 and 28.9% but tended to increase for the films deposited with PAr between 28.9 and 55.3%. Surface free energy increased with increasing PAr, except for the sample prepared at 28.9% of Ar, which presented the least reactive surface. Cells proliferated on all the samples, including the bare PVC. Independently of the deposition condition there was no evidence of cytotoxicity, indicating the viability of such coatings for designing biocompatible devices.

  15. COMPORTAMIENTO DE UN CEMENTO ASFÁLTICO MODIFICADO CON UN DESECHO DE PVC

    Directory of Open Access Journals (Sweden)

    Fredy Alberto Reyes Lizcano

    2013-06-01

    Full Text Available Las propiedades físicas y reológicas a altas temperaturas de servicio de un cemento asfáltico (CA modificado con un desecho de policloruro de vinilo (PVC fueron evaluadas y son presentadas en el artículo. Adicionalmente se presenta la influencia del tiempo de mezcla del CA con el PVC y el envejecimiento a corto plazo. Un incremento notable en la rigidez y la resistencia a fluir se reporta cuando se adiciona el desecho de PVC a un CA 80-100. De la misma forma, se reporta un incremento en la temperatura máxima de operación en servicio del ligante modificado.

  16. Evaluation of the influence of water and oil derivatives absorption on PVC pipes

    International Nuclear Information System (INIS)

    Carpio, D.C.F. del; D'Almeida, J.R.M.

    2010-01-01

    PVC is the only polymer of large consume that is not totally obtained from petroleum, since it contains 57% of chlorine. As chlorine containing materials are resistant to bacteria rich environments, such as buried pipes, PVC is being used for fluid transportation, principally water, but it can also be considered as an alternative material for the transportation of other fluids. This work analyzes the aging behavior of PVC exposed to water, ethanol and diesel oil, using TGA, DSC, FT-IR and DR-X techniques. The results showed that the chemical structure of PVC is not affected by exposure to water and ethanol. For these fluids a dipolar interaction could be occurring, increasing at the beginning of the absorption process, the polymer thermal stability. The diesel oil caused plasticization, with reduction of the Tg since the beginning of the aging process. (author)

  17. Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing material

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of); Mohammadhosseini, Majid [Department of Chemistry, Faculty of Basic Sciences, Shahrood Branch, Islamic Azad University, Shahrood (Iran, Islamic Republic of); Haji-Mohammadrezazadeh, Saeed [Department of Chemistry, Payame Noor University, Ardakan (Iran, Islamic Republic of); Faridbod, Farnoush [Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Ganjali, Mohammad Reza [Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Meghdadi, Soraia [Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Davoodnia, Abolghasem [Department of Chemistry, Faculty of Sciences, Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of)

    2012-05-01

    According to a solution study which showed a selective complexation between N,N Prime -bis(methylsalicylidene)-2-aminobenzylamine (MSAB) and gadolinium ions, MSAB was used as a sensing element in construction of a gadolinium(III) ion selective electrode. Acetophenon (AP) was used as solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode showed a good selectivity towards Gd(III) ions over a wide variety of cations tested. The constructed sensor displayed a Nernstian behavior (19.7 {+-} 0.3 mV/decade) in the concentration range of 1.0 Multiplication-Sign 10{sup -6} to 1.0 Multiplication-Sign 10{sup -2} mol L{sup -1} with detection limit of 5.0 Multiplication-Sign 10{sup -7} mol L{sup -1} and a short response time (< 10 s). The working pH range of the electrode was 3.5-10.1 and lifetime of the sensor was at least 10 weeks. Analysis of certified reference materials confirmed the accuracy of the proposed sensor. The electrode was successfully applied as an indicator electrode in gadolinium titration with EDTA. - Highlights: Black-Right-Pointing-Pointer A Gd{sup 3+}-PVC membrane sensor based on an ion carrier as sensing material is introduced. Black-Right-Pointing-Pointer This technique is very simple and it's not necessary to use sophisticated equipment. Black-Right-Pointing-Pointer This sensor shows good selectivity against other metal ions.

  18. Study on plasma pre-functionalized PVC film grafted with TiO2/PVP to improve blood compatible and antibacterial properties

    International Nuclear Information System (INIS)

    Suganya, Arjunan; Shanmugavelayutham, Gurusamy; Rodríguez, Carmen Serra

    2017-01-01

    Research into the design of new biopolymers/polymer functionalized with nanoparticles is of tremendous interest to the medical sector, particularly with regard to blood-contacting devices. In this present study, a steady blood compatible and active antibacterial coating was fabricated by the grafting of titanium dioxide (TiO 2 )/polyvinylpyyrolidone (PVP) onto a polyvinyl chloride (PVC) film surface via the direct-current glow discharge plasma method. To enhance the chemical interaction between TiO 2 /PVP and PVC, the surfaces of the PVC films were functionalized by different plasmas (air, argon, and oxygen) before coating. In this study, the plasma parameters were varied, such as treatment time of about 5–20 min for a constant power of 100 W, potential 300 V, and a constant gas pressure of 2 Pa for air, argon, and oxygen gas environment. Then, the different plasma treatments on the PVC films, TiO 2 /PVP were grafted using a simple dip-coating method. In addition, the TiO 2 /PVP-grafted PVC films were characterized by contact angle, attenuated total reflectance Fourier transform infrared spectroscopy, field-emission scanning electron microscope, and x-ray photo electron spectroscopy. Importantly, TiO 2 /PVP is grafted onto the PVC surface due to the plasma-based retained functionality and demonstrates adhesive efficiency, which was observed by XPS. The bio-stability of the TiO 2 /PVP-modified PVC film was evaluated by in vitro platelet activation analysis and protein adsorption analysis. Then, the antibacterial properties were evaluated by the agar diffusion method against Escherichia coli . The result reveals that the grafting of TiO 2 /PVP was slightly higher for the 15 min oxygen plasma-functionalized PVC, which significantly decreases the platelet adhesion and protein adsorption. Moreover, the antibacterial properties of the 15 min oxygen plasma-functionalized PVC with TiO 2 /PVP-grafted film is also greatly improved compared with an air- and argon

  19. High photocatalytic degradation activity of the polyvinyl chloride (PVC)-vitamin C (VC)-TiO2 nano-composite film

    International Nuclear Information System (INIS)

    Yang Changjun; Gong Chuqing; Peng Tianyou; Deng Kejian; Zan Ling

    2010-01-01

    A novel photodegradable polyvinyl chloride (PVC)-vitamin C (VC)-TiO 2 nano-composite film was prepared by embedding VC modified nano-TiO 2 photocatalyst into the commercial PVC plastic. The solid-phase photocatalytic degradation behavior of PVC-VC-TiO 2 nano-composite film under UV light irradiation was investigated and compared with those of the PVC-TiO 2 film and the pure PVC film, with the aid of UV-Vis spectroscopy, scanning electron microscopy (SEM), weight loss monitoring, and X-ray diffraction spectra (XRD). The results show that PVC-VC-TiO 2 nano-composite film has a high photocatalytic activity; the photocatalytic degradation rate of it is two times higher than that of PVC-TiO 2 film and fifteen times higher than that of pure PVC film. The optimal mass ratio of VC to TiO 2 is found to be 0.5. The mechanism of enhancing photocatalytic activity is attributed to the formation of a Ti IV -VC charge-transfer complex with five-member chelate ring structure and a rapid photogenerated charge separation is thus achieved.

  20. Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore.

    Science.gov (United States)

    Mahajan, Rakesh Kumar; Kamal, Ajar; Kumar, Naresh; Bhalla, Vandana; Kumar, Manoj

    2013-05-01

    The construction and electrodes characteristics of poly(vinylchloride) (PVC)-based polymeric membrane electrode (PME) and coated graphite electrode (CGE), incorporating 1,3-alternate thiacalix[4]crown as ionophore for estimation of Hg(II) ions, are reported here. The best potential response was observed for PME-1 having membrane composition of: ionophore (6.2 mg), PVC (100.0 mg), 2-nitrophenyl octyl ether (2-NPOE; 200.0 mg), and sodium tetraphenyl borate (NaTPB; 2.0 mg); for CGE-1 with the membrane composition: ionophore (3.5 mg), PVC (40.0 mg), 2-NPOE (80.0 mg), and NaTPB (2.0 mg). The electrodes exhibits Nernstian slope of 29.16 mV/decade with PME-1 and 30.39 mV/decade with CGE-1 for Hg(II) ions over wide concentration range, i.e., 1.0 × 10(-1) to 5.0 × 10(-6) M with PME-1 and 1.0 × 10(-1) to 5.0 × 10(-7) M with CGE-1. Lower detection limits were found to be 9.77 × 10(-6) M for PME-1 and 7.76 × 10(-7) M for CGE-1 with response time varying from 10 to 20 s. Also, these electrodes work within pH range of 2.0-6.0 for PME-1 and 1.5-6.5 for CGE-1. Overall, CGE-1 has been found to be better than PME-1. CGE-1 has been used as indicator electrode for the potentiometric titration of Hg(II) ions with EDTA as well as successfully applied for determination of Hg(II) content in wastewater, insecticide, dental amalgam, and ayurvedic medicines samples with very good performance (0.9974 correlation coefficient in the comparison against volumetric method).

  1. Chalk effect on PVC cross-linking under irradiation; Vliyanie mela na sshivanie PVKh pri obluchenii

    Energy Technology Data Exchange (ETDEWEB)

    Chudinova, V V; Guzeev, V V; Mozzhukhin, V B; Pomerantseva, Eh G; Nozrina, F D; Zhil` tsov, V V; Zubov, V P

    1994-12-31

    Effect of nonmodified and modified chalk on curing degree of polymer matrix was studied under-irradiation of PVC-compositions. Films of the compositions (100 mass part 7 PVC, 0-100 mas.part of chalk, 2.5 - lead sulfate, 1.5 - lead stearate and 0.3 - glycerin) were irradiated up to absorbed dose 0.1 MGy in an inert medium. Content of gel-fraction after boiling in THF was determined with use of IR spectroscopy. It was established, that intensive dehydrochlorination and polymer curing took place on chalk particle surface. Network fixed strongly chalk particles. However, chalk inhibited processes of dehydrochlorination and PVC curing, increasing amount of noncured PVC in polymer matrix.

  2. Dose Rate Effect on Grafting by Gamma Radiation of DMAEMA onto Flexible PVC

    International Nuclear Information System (INIS)

    Panzarini, L.C.G.A.; Araujo, F.D.C.; Martinello, V.C.; Somesari, E.; Manzoli, J.E.; Silveira, C.; Paes, H.A.; Moura, E.

    2009-01-01

    Intravenous tubing, blood bags and catheters stays in contact with blood and body fluids. They are normally made by flexible PVC. The contact of PVC with this fluid is not possible for long periods and there is the necessity of addition of non-thrombogenic substances into blood. This work shows the radiation grafting process to produce copolymer PVC-g-DMAEMA, a new material that allows a future grafting of Heparin on it, and will have the perspective of avoiding undesirable substances additions to blood or body fluid contact. In this preliminary work, only radiation dose rate effect on grafting was studied

  3. Blendas PVC/NBR por processamento reativo I: desenvolvimento do processo de vulcanização Dinâmica in situ PVC/NBR blends by reactive processing I: in situ dynamic vulcanization process

    Directory of Open Access Journals (Sweden)

    Fábio R. Passador

    2007-06-01

    Full Text Available Vulcanização dinâmica é o processo de vulcanização de um elastômero durante a mistura no estado fundido com um termoplástico, que resulta em uma classe de materiais denominada termoplásticos vulcanizados. Neste trabalho, um novo tipo de termoplástico vulcanizado foi obtido por vulcanização dinâmica in situ da blenda PVC/NBR, utilizando-se um sistema de cura a base de enxofre (S e combinação dos aceleradores 2,2-ditiomercaptobenzotiazol (MBTS e dissulfeto de tetrametiltiuram (TMTD. As blendas PVC/NBR (90/10, 80/20 e 70/30% em massa foram processadas em um reômetro de torque Haake (Rheomix 600 a 160 °C com rotação de 60 rpm. As blendas obtidas por processamento reativo foram caracterizadas por calorimetria diferencial de varredura (DSC para determinação do grau de cura. Observou-se aumento no grau de cura das blendas com o tempo de mistura sendo o sistema de cura considerado eficiente.Dynamic vulcanization is a process of vulcanization of an elastomer during melt mixing with a thermoplastic wich results in material called thermoplastic vulcanizates or TPVs. In this study, a new kind of TPV was obtained by in situ dynamic curing of poly(vinyl chloride (PVC/nitrile rubber (NBR blends. The crosslinking of PVC/NBR blends was accomplished using sulphur (S/tetramethylthiuram disulphide (TMTD and mercaptobenzthiazyl disulphide (MBTS curative system during the reactive processing. The blends of PVC/NBR at the ratio of 90/10; 80/20 and 70/30 wt. (% were melt mixed using a Haake Rheomix 600 at 160 °C and rotor speed of 60 rpm. The curing behavior of NBR was investigated by a Monsanto Rheometer and the degree of cure was calculated using differential scanning calorimetry (DSC for different mixing times. It was observed that the degree of cure increases with the mixing time and the crosslinking system used in this work was considered efficient.

  4. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  5. Influência do tipo de agente de partição da borracha nitrílica na obtenção de blendas PVC/NBR Influence of the partitioning agent on the preparation of PVC/NBR Blends

    Directory of Open Access Journals (Sweden)

    Fábio R. Passador

    2008-09-01

    Full Text Available Borrachas nitrílicas para utilização em misturas com PVC são fornecidas em forma de pó, que são recobertas com um agente de partição para evitar compactação do produto no transporte e armazenamento, além de garantir alta fluidez e livre escoamento. Neste trabalho, buscou-se estudar a influência do tipo de agente de partição da borracha nitrílica (resina de PVC e CaCO3 na obtenção de blendas PVC/NBR. As propriedades mecânicas das blendas foram avaliadas por ensaios de tração, rasgo e dureza. As blendas com NBR com agente de partição de PVC apresentaram maior tensão na ruptura e módulo elástico que as blendas em que utilizaram NBR com agente de partição de CaCO3. A morfologia foi avaliada por microscopia eletrônica de varredura sendo bastante afetada pelo tipo de agente de partição.Nitrile rubbers used in mixture with PVC resin are supplied in powder. This kind of nitrile rubber has a partitioning agent to avoid agglomeration in the particles during the transport and storage. In this study, the influence of the partitioning agent on the preparation of PVC/NBR blends was investigated. The mechanical properties of the blends were evaluated by tensile properties, tear strength and hardness. The PVC/NBR blends with partitioning agent of PVC showed an increase in the tensile stress and Young's modulus compared to the PVC/NBR blends with partitioning agent of CaCO3. The morphology of the blends examined by scanning electron microscopy demonstrated the influence of the partitioning agent.

  6. Utilization of Agrowaste Polymers in PVC/NBR Alloys: Tensile, Thermal, and Morphological Properties

    Directory of Open Access Journals (Sweden)

    Ahmad Mousa

    2012-01-01

    Full Text Available Poly(vinyl chloride/nitrile butadiene rubber (PVC/NBR alloys were melt-mixed using a Brabender Plasticorder at 180∘C and 50 rpm rotor speed. Alloys obtained by melt mixing from PVC and NBR were formulated with wood-flour- (WF- based olive residue, a natural byproduct from olive oil extraction industry. WF was progressively increased from 0 to 30 phr. The effects of WF loadings on the tensile properties of the fabricated samples were inspected. The torque rheometry, which is an indirect indication of the melt strength, is reported. The pattern of water uptake for the composites was checked as a function WF loading. The fracture mode and the quality of bonding of the alloy with and without filler are studied using electron scanning microscope (SEM.

  7. The pvc operon regulates the expression of the Pseudomonas aeruginosa fimbrial chaperone/usher pathway (cup genes.

    Directory of Open Access Journals (Sweden)

    Uzma Qaisar

    Full Text Available The Pseudomonas aeruginosa fimbrial structures encoded by the cup gene clusters (cupB and cupC contribute to its attachment to abiotic surfaces and biofilm formation. The P. aeruginosa pvcABCD gene cluster encodes enzymes that synthesize a novel isonitrile functionalized cumarin, paerucumarin. Paerucumarin has already been characterized chemically, but this is the first report elucidating its role in bacterial biology. We examined the relationship between the pvc operon and the cup gene clusters in the P. aeruginosa strain MPAO1. Mutations within the pvc genes compromised biofilm development and significantly reduced the expression of cupB1-6 and cupC1-3, as well as different genes of the cupB/cupC two-component regulatory systems, roc1/roc2. Adjacent to pvc is the transcriptional regulator ptxR. A ptxR mutation in MPAO1 significantly reduced the expression of the pvc genes, the cupB/cupC genes, and the roc1/roc2 genes. Overexpression of the intact chromosomally-encoded pvc operon by a ptxR plasmid significantly enhanced cupB2, cupC2, rocS1, and rocS2 expression and biofilm development. Exogenously added paerucumarin significantly increased the expression of cupB2, cupC2, rocS1 and rocS2 in the pvcA mutant. Our results suggest that pvc influences P. aeruginosa biofilm development through the cup gene clusters in a pathway that involves paerucumarin, PtxR, and different cup regulators.

  8. CORRELATION OF THE GLASS TRANSITION TEMPERATURE OF PLASTICIZED PVC USING A LATTICE FLUID MODEL

    Science.gov (United States)

    A model has been developed to describe the composition dependence of the glass transition temperature (Tg) of polyvinyl chloride (PVC) + plasticizer mixtures. The model is based on Sanchez-Lacombe equation of state and the Gibbs-Di Marzio criterion, which states that th...

  9. Investigation of PVC physical ageing in field test specimens using ultrasonic and dielectric measurements

    NARCIS (Netherlands)

    Demcenko, A.; Ravanan, M.; Visser, Roy; Loendersloot, Richard; Akkerman, Remko

    2013-01-01

    Physical ageing in PVC is studied using two techniques: a) non-linear ultrasonic measurements based on the non-collinear wave interaction theory and b) dielectric measurements. The ultrasonic measurement results are compared with dielectric measurement results. The comparison shows that the used

  10. PVC posting bags for glove boxes

    International Nuclear Information System (INIS)

    1976-12-01

    This specification covers the materials, measurements and manufacture of unpigmented PVC posting bags for use on glove boxes, together with methods of testing the materials. These bags are used in the handling of radioactive and toxic materials of a hazardous nature and therefore must be of the highest standard of mechanical strength, leak tightness and general finish. (author)

  11. Vida útil e metabolismo de carboidratos em raízes de mandioquinha-salsa sob refrigeração e filme de PVC Shelf life and carbohydrate metabolism of arracacha roots stored under refrigeration and PVC film

    Directory of Open Access Journals (Sweden)

    Rosilene Antonio Ribeiro

    2007-04-01

    Full Text Available O objetivo deste trabalho foi avaliar a influência da temperatura de armazenamento e do uso do filme de cloreto de polivinila (PVC sobre a perda de matéria fresca e água, incidência de danos causados por frio e metabolismo pós-colheita dos carboidratos, em raízes tuberosas de mandioquinha-salsa (Arracacia xanthorrhiza. O filme de PVC reduziu a perda de matéria fresca e manteve o teor de água das raízes, durante o armazenamento por 60 dias a 5 e 10ºC. Os danos causados por frio foram inibidos nas raízes embaladas em filme de PCV, em ambas as temperaturas de armazenamento. As baixas temperaturas induziram o acúmulo de açúcares solúveis e a degradação de amido e, para as raízes armazenadas sem PVC, o aumento do conteúdo dos açúcares solúveis foi transiente e a taxa de degradação de amido foi superior à das raízes armazenadas com PVC.The objective of this work was to evaluate the influence of the storage temperature and stretch polyvinylchloride (PVC film on the loss of fresh weight and water, on the development of chilling injury symptoms, and on the postharvest metabolism of carbohydrates, in arracacha tuber roots (Arracacia xanthorrhiza. The PVC film reduced the fresh weight loss and kept water content in the roots during 60-day storage period at 5 and 10ºC. PVC film in both storage temperatures inhibited the development of external and internal chilling injury symptoms. The low temperatures induced the increase of soluble sugar content and decrease of starch concentration, where the increase in soluble sugar was transient in roots stored without PVC film, and the rate of starch degradation was higher compared to the roots stored with PVC.

  12. Plastics piping systems for industrial applications – Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) – Specifications for components and the system – Metric series

    CERN Document Server

    Deutsches Institut für Normung. Berlin

    2003-01-01

    Plastics piping systems for industrial applications – Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) – Specifications for components and the system – Metric series

  13. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    International Nuclear Information System (INIS)

    Wang, Ming-Qiu; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-01-01

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via N-Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni–P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni–P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  14. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ming-Qiu, E-mail: mqwang1514@163.com; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-07-15

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via N-Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni–P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni–P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  15. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    Science.gov (United States)

    Wang, Ming-Qiu; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-07-01

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via Nsbnd Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni-P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni-P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  16. Degradation behavior of PVC film in aqueous solution at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Shun-Myung; Kim, Jong-Hwa; Lee, Soo [Changwon National University, Changwon(Korea)

    2001-02-28

    The heat treatment of PVC film containing PVC 65%, DOP (Dioctyl Phthalate) 32% as plasticizer, Ca-Zn stearates and surface agent was performed under several conditions to study the dehydrochlorination of PVC and char production. In the case of H{sub 2}SO{sub 4}, the dehydrochlorination was ca.100% at 250 deg.C for 3h. The char involving the smaller pores was produced with hydrothermal treatment. The pore size became small with increasing the treatment time and temperature. In the case of treatment with Ca(OH){sub 2}, the sizes of pores produced in char were about sever {approx}10 {mu}m at 225 deg.C for 12h. In the case of H{sub 2}SO{sub 4}, the size of pores were about 1 {mu}m in 5M H{sub 2}SO{sub 4} for 12h. (author). 6 refs., 3 tabs., 11 figs.

  17. Dysprosium selective potentiometric membrane sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zamani, Hassan Ali, E-mail: haszamani@yahoo.com [Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad (Iran, Islamic Republic of); Faridbod, Farnoush; Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of)

    2013-03-01

    A novel Dy(III) ion-selective PVC membrane sensor was made using a new synthesized organic compound, 3,4-diamino-N Prime -((pyridin-2-yl)methylene)benzohydrazide (L) as an excellent sensing element. The electrode showed a Nernstian slope of 19.8 {+-} 0.6 mV per decade in a wide concentration range of 1.0 Multiplication-Sign 10{sup -6}-1.0 Multiplication-Sign 10{sup -2} mol L{sup -1}, a detection limit of 5.5 Multiplication-Sign 10{sup -7} mol L{sup -1}, a short conditioning time, a fast response time (< 10 s), and high selectivity towards Dy(III) ion in contrast to other cations. The proposed sensor was successfully used as an indicator electrode in the potentiometric titration of Dy(III) ions with EDTA. The membrane sensor was also applied to the F{sup -} ion indirect determination of some mouth washing solutions and to the Dy{sup 3+} determination in binary mixtures. Highlights: Black-Right-Pointing-Pointer The novelty of this work is based on the high affinity of the ionophore toward the Dy{sup 3+} ions. Black-Right-Pointing-Pointer This technique is very simple, fast and inexpensive and it is not necessary to use sophisticated equipment. Black-Right-Pointing-Pointer The newly developed sensor is superior to the formerly reported Dy{sup 3+} sensors in terms of selectivity.

  18. The 1st EMBO workshop on PVC bacteria-Planctomycetes-Verrucomicrobia-Chlamydiae superphylum: exceptions to the bacterial definition?

    Science.gov (United States)

    Devos, Damien P; Jogler, Christian; Fuerst, John A

    2013-10-01

    The PVC superphylum is a phylogenetically supported collection of various related bacterial phyla that comprise unusual characteristics and traits. The 'PVC' abbreviation derives from Planctomycetes, Verrucomicrobia and Chlamydiae as members of this superphylum, while additional bacterial phyla are related. There has recently been increasing and exciting interest in the cell biology, physiology and ecology of members of this superphylum, including evolutionary implications of the complex cell organization of some species. It is timely that international researchers in the PVC superphylum field met to discuss these developments. The first meeting entirely dedicated to those bacteria, the EMBO workshop "PVC superphylum: Exceptions to the bacterial definition" was held at the Heidelberg University to catalyze the formation of a vital scientific community supporting PVC-bacterial research. More than 45 investigators from more than 20 countries (PIs, senior scientists and students) attended the meeting and produced a great starting point for future collaborative research. This Special Issue will focus on the EMBO-PVC meeting. This Perspective briefly summarizes the history of PVC-research, focusing on the key findings and provides a brief summary of the meeting with a focus on the major questions that arose during discussion and that might influence the research in the years to come.

  19. Synthesis of AzPhchitosan-bifenthrin-PVC to protect cables against termites.

    Science.gov (United States)

    Zhang, Lingkun; Cai, Weiwei; Chen, Wu-Ya; Zhang, Li; Hu, Kaikai; Guan, Yan-Qing

    2016-03-30

    The destruction of PVC cables by termites is a continuing and long-standing problem, which can lead to power leakage and power cut. Given the environmental demerits of insecticide overuse, alternative methods of addressing this problem are a highly desirable goal. In this study, we used photo-immobilization to develop a chitosan carrier system to help bifenthrin immobilize on the surface of the PVC substrate. The immobilization was analyzed using nuclear magnetic resonance (NMR), UV absorption, reverse-phase high-performance liquid chromatography (RP-HPLC), Raman absorption spectroscopy, and thermal gravimetric analysis (TGA). The surface structure and biological activity of the embedded and immobilized bifenthrin were examined using scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photon-electron spectroscopy (XPS). Its efficacy was assessed in pest experiments. The results indicate a successful embedding and immobilization of bifenthrin. Furthermore, the chemical bonding network between AzPhchitosan, bifenthrin, and PVC is stable, guaranteeing no environmental release of bifenthrin, and also providing more efficacious protection against termites. The evidence suggests that this photo-immobilization of bifenthrin-embedded chitosan on the surface of PVC substrates is a novel and environmentally friendly technique for termite control. This paper also reports a modification of chitosan with respect to its novel application in environmental protection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Analysis of Phthalate Ester Content in PVC Plastics by means of FT-Raman Spectroscopy

    DEFF Research Database (Denmark)

    Nørbygaard, Thomas; Berg, Rolf W.

    2004-01-01

    Polyvinyl chloride, PVC or [CH2-CHCl]n , is a common polymer used extensively for a wide range of industrial and household products. To achieve the proper material characteristics (e.g. softness, ductility), plasticizers such as phthalates are usually added to the otherwise hard and brittle PVC......, medical devices and toys may harm the e.g. reproductive organs of exposed infants. PVC is readily distinguished from other common polymers (e.g. polyethylene, polypropylene, polystyrene) by the use of Raman spectroscopy. By far the most commonly used phthalate plasticizer in PVC is di(2-ethylhexyl......-phenyl group, and as the relative intensities of the six bands vary only slightly from one phthalate ester to the next one we have obtained an identifiable, characteristic fingerprint of the phthalate ester group as a whole. By use of the set of six bands, which are common to all the measured Raman spectra, we...

  1. Information-based self-organization of sensor nodes of a sensor network

    Science.gov (United States)

    Ko, Teresa H [Castro Valley, CA; Berry, Nina M [Tracy, CA

    2011-09-20

    A sensor node detects a plurality of information-based events. The sensor node determines whether at least one other sensor node is an information neighbor of the sensor node based on at least a portion of the plurality of information-based events. The information neighbor has an overlapping field of view with the sensor node. The sensor node sends at least one communication to the at least one other sensor node that is an information neighbor of the sensor node in response to at least one information-based event of the plurality of information-based events.

  2. Silver ion recognition using potentiometric sensor based on recently synthesized isoquinoline-1,3-dione derivatives

    Directory of Open Access Journals (Sweden)

    AJAR KAMAL

    2012-08-01

    Full Text Available The four derivatives of isoquinoline-1,3-dione based on β-lactum (I-IV, have been explored as neutral ionophores for preparing poly(vinylchloride based polymeric membrane electrodes (PME selective to silver(I ions. The addition of sodium tetraphenylborate (NaTPB and dioctylsebacate (DOS as a plasticizer was found to improve the performance of ion selective electrodes. The best performance was obtained with PME-1 based on ionophore I having composition: ionophore (9.2 mg, PVC (100.1 mg, DOS (201.1 mg and NaTPB (1.5 mg in 5 mL tetrahydrofuran. The electrode response was linear with Nernstian slope of 58.44 mV/decade in the concentration range of 1.0 x 10-1 M to 5.0 x 10-6 M and detection limit of 5.83 x 10-6 M. It performs satisfactorily over wide pH range of 1.0-5.5. The proposed sensor can be used over a period of more than three months without any significant drift in potential and shows good selectivity to silver(I ion over a number of cations especially with no interference of mercury(II ions. Sharp end point was obtained when the sensor was used as an indicator electrode for the potentiometric titration of silver(I ions with chloride ions and therefore this electrode (PME-1 could be used for quantitative determination of silver(I ion in synthetic water, silver foil and dental amalgam samples.

  3. High photocatalytic degradation activity of the polyvinyl chloride (PVC)-vitamin C (VC)-TiO{sub 2} nano-composite film

    Energy Technology Data Exchange (ETDEWEB)

    Yang Changjun; Gong Chuqing; Peng Tianyou [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Deng Kejian [Key Laboratory of Catalysis and Materials Science of the State Ethnic Affairs Commission and Ministry of Education, South-Central University for Nationalities, Wuhan 430074 (China); Zan Ling, E-mail: irlab@whu.edu.cn [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)

    2010-06-15

    A novel photodegradable polyvinyl chloride (PVC)-vitamin C (VC)-TiO{sub 2} nano-composite film was prepared by embedding VC modified nano-TiO{sub 2} photocatalyst into the commercial PVC plastic. The solid-phase photocatalytic degradation behavior of PVC-VC-TiO{sub 2} nano-composite film under UV light irradiation was investigated and compared with those of the PVC-TiO{sub 2} film and the pure PVC film, with the aid of UV-Vis spectroscopy, scanning electron microscopy (SEM), weight loss monitoring, and X-ray diffraction spectra (XRD). The results show that PVC-VC-TiO{sub 2} nano-composite film has a high photocatalytic activity; the photocatalytic degradation rate of it is two times higher than that of PVC-TiO{sub 2} film and fifteen times higher than that of pure PVC film. The optimal mass ratio of VC to TiO{sub 2} is found to be 0.5. The mechanism of enhancing photocatalytic activity is attributed to the formation of a Ti{sup IV}-VC charge-transfer complex with five-member chelate ring structure and a rapid photogenerated charge separation is thus achieved.

  4. Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

    Science.gov (United States)

    Widenor, W. M.

    1978-01-01

    A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

  5. A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements

    Directory of Open Access Journals (Sweden)

    Ayman H. Kamel

    2011-01-01

    Full Text Available Iron(II-(1,10-phenanthroline complex imprinted membrane was prepared by ionic imprinting technology. In the first step, Fe(II established a coordination linkage with 1,10-phenanthroline and functional monomer 2-vinylpyridine (2-VP. Next, the complex was copolymerized with ethylene glycol dimethacrylate (EGDMA as a crosslinker in the presence of benzoyl peroxide (BPO as an initiator. Potentiometric chemical sensors were designed by dispersing the iron(II-imprinted polymer particles in 2-nitrophenyloctyl ether (o-NPOE plasticizer and then embedded in poly vinyl chloride (PVC matrix. The sensors showed a Nernstian response for [Fe(phen3]2+ with limit of detection 3.15 ng mL−1 and a Nernstian slope of 35.7 mV per decade.

  6. Production of PVC/Abs/Nbr blend and the study of its physical and mechanical properties, thermal behaviour and its morphology

    International Nuclear Information System (INIS)

    Mehrabzadeh, M.; Honarkar, H.

    2001-01-01

    In this research a product of triplet blend of polyvinyl chloride, acrylonitrile-butadiene-styrene, acrylonitrile butadiene rubber (PVC/Abs/Nbr) is obtained. The physical, mechanical and thermal behaviour as well as morphology of the blend were studied. Results show that optimum properties in ratio PVC/Abs: 60/40 is obtained. For substituting the Nbr by a portion of Dop to modify the migration to surface, a triplet blend of PVC/Abs/Nbr was made. Experiments with constant amount of Nbr and variable Dop and vice versa were carried out. For preparation of triplet blend from PVC/Abs, a ratio of 60/40 was used. The best results were obtained for a blend with Nbr (10%) and PVC powder, 20% Nbr and PVC granules containing 34% Dop and the thermo formability of PVC/Abs/Nbr blend was examined as well

  7. Miniaturized membrane sensors for potentiometric determination of metoprolol tartrate and hydrochlorothiazide.

    Science.gov (United States)

    Ramadan, Nesrin K; Mohamed, Heba M; Mostafa, Azza A

    2012-06-01

    Four microsized graphite and platinum wire poly(vinyl chloride) matrix membrane electrodes responsive to some drugs affecting cardiovascular system, Metoprolol tartrate (MT) and Hydrochlorothiazide (HZ) were developed, described and characterized. These sensors were constructed by using (2-Hydroxypropyl)-β-cyclodextrin (2HP β-CD) as an ionophore which has a significant influence on increasing both membrane sensitivity and selectivity. The four sensors were fabricated in a polymeric matrix of carboxylated polyvinyl chloride (PVC-COOH) and dioctylphthalate (DOP) as a plasticizer, based on the interaction between the drugs and the dissociated COOH groups in the PVC-COOH. Fast and stable Nernstian responses of 1.0 × 10-6-1.0 × 10-2 M for MT (sensors 1 and 2) and of 1.0 × 10-7-1.0 × 10-3 M for HZ (sensors 3 and 4) over pH range 3.0-9.0 and 3.0-7.0 for the MT and HZ sensors respectively were obtained. Nernstian slopes of 56.2, 54.6, 19.0 and 20.8 mV/decade for electrodes 1-4 respectively were observed. The proposed method displayed useful analytical characteristics for the determination of MT and HZ in their pure powder forms with average recoveries of 99.11 ± 0.357, 99.21 ± 0.389, 100.08 ± 0.459 and 100.28 ± 0.438% for sensors 1-4 respectively. The lower limit of detection (LOD) were 5.5 × 10-6, 4.5 × 10-6, 4.8 × 10-8 and 5.0 × 10-8 M for sensors 1-4 respectively indicated high sensitivity. The four sensors displayed a good stability over a period of 6 weeks. The selectivity coefficients of the developed sensors indicated excellent selectivity. Results obtained by the four electrodes revealed the performance characteristics of these electrodes which evaluated according to IUPAC recommendations. The method was successively applied for the determination of MT and HZ in presence of each other, in presence of Salamide (SA), the main degradation product of HZ, in their pharmaceutical formulations and in human plasma samples. Statistical comparison between the

  8. Improving the Healthiness of Sustainable Construction: Example of Polyvinyl Chloride (PVC

    Directory of Open Access Journals (Sweden)

    Emina Kristina Petrović

    2018-02-01

    Full Text Available With the increasing emphasis on sustainable construction, it has become important to better understand the impacts of common materials. This is especially paramount with the introduction of the United Nations (UN Sustainable Development Goals (SDGs which call for more comprehensive evaluations, adding many aspects of social consideration to the issues of environmental sustainability, including human health. Polyvinyl chloride (PVC/vinyl can be seen as a material with potential for significant adverse effects on a multiplicity of levels, and the construction industry is its single most significant consumer. This article presents a transdisciplinary review of adverse health impacts associated with PVC showing a number of issues: some that could be eliminated through design, but also some which appear inherent to the material itself and therefore unavoidable. The totality of issues revealed in relation to PVC presents a compelling case for a call for complete elimination of use of this material in sustainable construction.

  9. Producción y modelamiento de gliceril-ésteres como plastificantes para PVC / Production et modelisation de glycerol-esters comme plastifiants pour le PVC

    OpenAIRE

    Suárez Palacios, Oscar Yesid

    2011-01-01

    El aumento en la producción mundial de glicerina, debido al crecimiento en el uso de biodiesel, y la tendencia a reemplazar los plastificantes derivados del anhídrido ftálico en la industria del PVC, por la toxicidad de dichas sustancias, motivaron la investigación de la plastificación del PVC con gliceril-ésteres derivados de ácidos carboxílicos de cadena corta (C3 - C8) y aromáticos. En este estudio se aplicó una metodología de diseño de producto para abordar la solución a las problemáticas...

  10. Reputation-based secure sensor localization in wireless sensor networks.

    Science.gov (United States)

    He, Jingsha; Xu, Jing; Zhu, Xingye; Zhang, Yuqiang; Zhang, Ting; Fu, Wanqing

    2014-01-01

    Location information of sensor nodes in wireless sensor networks (WSNs) is very important, for it makes information that is collected and reported by the sensor nodes spatially meaningful for applications. Since most current sensor localization schemes rely on location information that is provided by beacon nodes for the regular sensor nodes to locate themselves, the accuracy of localization depends on the accuracy of location information from the beacon nodes. Therefore, the security and reliability of the beacon nodes become critical in the localization of regular sensor nodes. In this paper, we propose a reputation-based security scheme for sensor localization to improve the security and the accuracy of sensor localization in hostile or untrusted environments. In our proposed scheme, the reputation of each beacon node is evaluated based on a reputation evaluation model so that regular sensor nodes can get credible location information from highly reputable beacon nodes to accomplish localization. We also perform a set of simulation experiments to demonstrate the effectiveness of the proposed reputation-based security scheme. And our simulation results show that the proposed security scheme can enhance the security and, hence, improve the accuracy of sensor localization in hostile or untrusted environments.

  11. Effects of 60 MeV C5+ ion irradiation on PmT-PVC and p-TSA doped PoT-PVC blends

    International Nuclear Information System (INIS)

    Lakshmi, G.B.V.S.; Siddiqui, Azher M.; Ali, Vazid; Kulriya, Pawan K.; Zulfequar, M.

    2008-01-01

    Poly(m-toluidine) (PmT) and Poly(o-toluidine) (PoT) have been synthesized from derivatives of aniline (m-toluidine), (o-toluidine) monomers by chemical oxidative polymerization method. After polymerization, PoT powder was doped with p-toluene sulphonic acid (p-TSA) and the polymer powders were blended with poly vinyl chloride (PVC) to achieve PmT and p-TSA doped PoT dispersed films. XRD, FTIR and UV-visible studies were carried out to get their structural changes and optical information. These blends were irradiated by 60 MeV C 5+ ions with different fluences. Post Irradiation XRD, FTIR and UV-visible spectroscopy were also performed on all films. On p-TSA doped PoT-PVC blends dc-conductivity measurements are also carried out before and after irradiation. The results show structural modifications which lead to changes in optical and electrical properties

  12. Mechanical behavior of styrene grafted PVC films by electron beam irradiation

    International Nuclear Information System (INIS)

    Cardoso, Jessica R.; Moura, Eduardo; Somessari, Elisabeth S.R.; Silveira, Carlos G.; Paes, Helio A.; Souza, Carlos A.; Manzoli, Jose E.; Geraldo, Aurea B.C.

    2011-01-01

    The polyvinyl chloride (PVC) is a technological and low cost polymer, however it presents high sensitivity to high energy irradiation because of the weakness of carbon-chloride bond face to carbon-carbon and carbon-hydrogen bonds. Grafting is a type of co-polymerization process that can allow it an increase of mechanical characteristics. The aim of this work is to evaluate the mechanical properties of styrene grafted PVC by electron beam irradiation using mutual and pre-irradiation methods to verify the mechanical resistance changes of obtained product whether grafting process is applied from non-irradiated or from pre-irradiated substrates. The irradiation procedures were performed in atmosphere air or inert atmosphere and the irradiation conditions comprised doses from 10 kGy to 100 kGy and dose rates of 2.2 kGy/s and 22.4 kGy/s. The styrene grafted samples were analyzed by gravimetry to determinate the grafting yield; the final values have been averaged from a series of three measurements. The Mid-A TR-FTIR was the spectrophotometer technique used for qualitative/semi-quantitative analysis of grafted samples. The Young's module and tensile strength of pre-irradiated and grafted PVC samples at both methods were measured at a Lloyd LXR tensile tester at a cross-head speed of 10.00 mm/min. We observed the decrease of Young's module and tensile strength with the increase of absorbed dose at pre-irradiated PVC samples. These mechanical parameters results are discussed. (author)

  13. Electron beam processing of PVC insulating material in presence of additives

    International Nuclear Information System (INIS)

    Sharma, V.K.; Bhattacharyya, P.K.

    1994-01-01

    Using electron beam radiation flexible PVC (polyvinyl chloride) was cross linked in the dose range up to 15 Mrad. The effect of sensitizers and other additives on the cross linking and other physical properties like tensile strength have been investigated. It has been found that tri functional sensitizer like TMPTM (tri methyl propane tri methacrylate) is better sensitizer for PVC. In presence of TMPTM the physical properties related to crosslinking are found to be better than some of the other sensitizers used. The results are discussed. (author). 2 refs., 2 figs

  14. A new selectophore for gadolinium selective sensor

    International Nuclear Information System (INIS)

    Zamani, Hassan Ali; Faridbod, Farnoush; Ganjali, Mohammad Reza

    2014-01-01

    Based on a selective complexation of N′-(2-oxo-1,2-di(pyridin-2-yl)ethylidene)furan-2-carbohydrazide (L) with Gd(III) ions, it was used as a selectophore in construction of a Gd(III) selective PVC membrane sensor. Different compositions for the membrane were tested. The o-nitrophenyloctyl ether (NPOE) was used as suitable plasticizer, and a mixture of sodium tetraphenyl borate (NaTPB) and oleic acid (OA) as anion excluders. The proposed sensor displayed a Nernstian behavior with the slope of 19.9 ± 0.6 mV decade −1 in concentration range of 1.0 × 10 −6 to 1.0 × 10 −2 mol L −1 . Detection limit was 4.2 × 10 −7 mol L −1 and response time was ∼ 10 s. Applicable pH range of the electrode was 4.2–8.0. Lifetime of the sensor is at least 10 weeks. Analysis of certified reference materials confirmed the accuracy of the proposed electrode. - Highlights: • This work reports design of membrane sensor for monitoring of Gd3+ ions. • The novelty of this work is the high affinity of the ionophore toward the Gd3+ ions. • The sensor is superior to the formerly reported Gd3+ sensors in terms of selectivity

  15. Study on the gamma radiolysis of poly (vinyl chloride). Application to the study on degradation by irradiation and leaching of industrial PVC

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    The works presented in this memory enter in the context of the management of plastic nuclear waste. This study was carried out on pure PVC and industrial PVC (formulated polymer). The radiolysis at high doses (up to 4 MGy) of pure PVC in anaerobic condition involves the formation of polyenyl radicals, polyenic sequences, hydrogen chloride and reactions of crosslinking. In aerobic condition, the radiolysis at high doses of pure PVC generates the formation of peroxyl radicals, hydrogen chloride, acid water, carboxylic acids, saturated or conjugated ketones and phenomena of scission. The production of HCl generated by irradiation of industrial PVC was carried out up to 40 MGy. The HCl formed by radiolysis is completely trapped by the calcic loads contained in industrial PVC and by the water produced by these reactions of trapping. A qualitative study on the formation of the products of radiolysis highlighted that the mechanisms of radiolysis of industrial PVC are different from those of pure PVC. This difference is due to the presence of additives belonging to the formulation of industrial PVC. The irradiation of plasticizers such as phthalic esters could induce the formation of radicals being able to react, by reaction of grafting, with the macro-radicals of PVC or with the polyenic sequences formed by radiolysis of PVC macromolecules. The results of leaching experiments tend to confirm this type of mechanism. (author)

  16. Effects of low dose gamma irradiation on PVC blood bags containing anticoagulant CPDA solution

    International Nuclear Information System (INIS)

    Mitra, D.; Varshney, Lalit; Arjun, Chanda

    2006-01-01

    PVC blood bags were exposed to 20Gy and 60Gy low gamma radiation dose to investigate possibility of change in leaching behavior of the plasticizer into CPDA solution and the blood. Reversed phase HPLC was used for the investigations on anti coagulant solution CPDA(citrate, phosphate, dextrose and adenine) contained in PVC bag before and after gamma irradiation. The studies were repeated using methanol as an extractant instead of CPDA solution, considering higher extractability of plasticizer by blood. Irradiation of PVC bags by gamma radiation for a dose up to 60Gy does not lead to change in leaching behavior of the plasticizer in CPDA solution and methanol indicating similar expected behavior in blood. (author)

  17. CONTECH(R) A-2000 polyvinyl chloride (PVC) plastic pipe.

    Science.gov (United States)

    2015-03-01

    Determine the effectiveness and long-term durability of the Contech A-2000 PVC pipe : in an irrigation application. This type of pipe may prove to be a viable alternative to : reinforced concrete pipe (RCP).

  18. Structural, thermal, dielectric spectroscopic and AC impedance properties of SiC nanoparticles doped PVK/PVC blend

    Science.gov (United States)

    Alghunaim, Naziha Suliman

    2018-06-01

    Nanocomposite films based on poly (N-vinylcarbazole)/polyvinylchloride (PVK/PVC) blend doped with different concentrations of Silicon Carbide (SiC) nanoparticles have been prepared. The X-ray diffraction, Ultra violet-visible spectroscopy, thermogravimetric analysis and electrical spectroscopic has been used to characterize these nanocomposites. The X-ray analysis confirms the semi-crystalline nature of the films. The intensity of the main X-ray peak is decreased due to the interaction between the PVK/PVC and SiC. The main SiC peaks are absent due to complete dissolution of SiC in polymeric matrices. The UV-Vis spectra indicated that the band gap optical energy is affected by adding SiC nanoparticles because the charges transfer complexes between PVK/PVC with amount of SiC. The thermal stability is improved and the estimated values of ε‧ and ε″ are increased with increasing for SiC content due to the free charge carriers which in turn increase the ionic conductivity of the doped samples. The plots of tan δ with frequency are studied. A single peak from the plot between tan δ and Log (f) is appeared and shifted towards the higher frequency confirmed the presence of relaxing dipoles moment.

  19. Experimental Investigations on Combustion Behaviors of Live PVC Cables

    Science.gov (United States)

    Wang, Liufang; Zhang, Jiaqing; Zhang, Bosi; Liu, Min; Fan, Minghao; Li, Qiang

    2018-03-01

    This paper investigated the combustion behaviors of live PVC cables with overload currents experimentally. The smoke coefficient of released smoke and the released gas concentration were examined. The results indicate that the combustion of live PVC cables can be divided into four stages, i.e., core exposed with a little smoke, obvious flame, maximum smoke and smoke depress. For most cases, using blue laser is better than using rad laser, since the extinction coefficient of the rad laser was larger than that of the blue laser. The response time of the detection of the released typical gases due to cable pyrolysis decreased and the peak values of the typical gases increased with the overload currents. In addition, the time to reach the peak value of gas concentration also decreased with the overload currents.

  20. Mechanical behavior of styrene grafted PVC films by electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Jessica R.; Moura, Eduardo; Somessari, Elisabeth S.R.; Silveira, Carlos G.; Paes, Helio A.; Souza, Carlos A.; Manzoli, Jose E.; Geraldo, Aurea B.C., E-mail: ageraldo@ipen.br, E-mail: jmanzoli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The polyvinyl chloride (PVC) is a technological and low cost polymer, however it presents high sensitivity to high energy irradiation because of the weakness of carbon-chloride bond face to carbon-carbon and carbon-hydrogen bonds. Grafting is a type of co-polymerization process that can allow it an increase of mechanical characteristics. The aim of this work is to evaluate the mechanical properties of styrene grafted PVC by electron beam irradiation using mutual and pre-irradiation methods to verify the mechanical resistance changes of obtained product whether grafting process is applied from non-irradiated or from pre-irradiated substrates. The irradiation procedures were performed in atmosphere air or inert atmosphere and the irradiation conditions comprised doses from 10 kGy to 100 kGy and dose rates of 2.2 kGy/s and 22.4 kGy/s. The styrene grafted samples were analyzed by gravimetry to determinate the grafting yield; the final values have been averaged from a series of three measurements. The Mid-A TR-FTIR was the spectrophotometer technique used for qualitative/semi-quantitative analysis of grafted samples. The Young's module and tensile strength of pre-irradiated and grafted PVC samples at both methods were measured at a Lloyd LXR tensile tester at a cross-head speed of 10.00 mm/min. We observed the decrease of Young's module and tensile strength with the increase of absorbed dose at pre-irradiated PVC samples. These mechanical parameters results are discussed. (author)

  1. Bluetooth-based wireless sensor networks

    Science.gov (United States)

    You, Ke; Liu, Rui Qiang

    2007-11-01

    In this work a Bluetooth-based wireless sensor network is proposed. In this bluetooth-based wireless sensor networks, information-driven star topology and energy-saved mode are used, through which a blue master node can control more than seven slave node, the energy of each sensor node is reduced and secure management of each sensor node is improved.

  2. Development and characterization of a synthetic PVC/DEHP myocardial tissue analogue material for CT imaging applications.

    Science.gov (United States)

    Ramadan, Sherif; Paul, Narinder; Naguib, Hani E

    2018-04-01

    A simple myocardial analogue material has great potential to help researchers in the creation of medical CT Imaging phantoms. This work aims to outline a Bis(2-ethylhexyl) phthalate (DEHP) plasticizer/PVC material to achieve this. DEHP-PVC was manufactured in three ratios, 75, 80, and 85% DEHP by heating at 110 °C for 10 min to promote DEHP-PVC binding followed by heating at 150 °C to melt the blend. The material was then tested utilizing FTIR, tensile testing, dynamic mechanical analysis and imaged with computed tomography. The FTIR testing finds the presence of C-CL and carbonyl bonds that demonstrate the binding required in this plasticized material. The tensile testing finds a modulus of 180-20 kPa that increases with the proportion of plasticizer. The dynamic mechanical analysis finds a linear increase in viscoelastic properties with a storage/loss modulus of 6/.5-120/18 kPa. Finally, the CT number of the material increases with higher PVC content from 55 to 144HU. The 80% DEHP-PVC ratio meets the mechanical and CT properties necessary to function as a myocardial tissue analogue.

  3. Analysis of Adipate Ester Contents in PVC Plastics

    DEFF Research Database (Denmark)

    Berg, Rolf W.

    2006-01-01

    Plasticizers are needed in flexible PVC (PolyVinylChloride) products. There is serious concern that commonly used phthalate esters may harm life reproduction systems. To avoid the problems, instead adipate di-esters (AEs) of C8 to C10 alcohols are used as higher prized alternatives; e.g. di-2......-ethylhexyl adipate or DEHA [103-23-1], also known as Adimoll® or di-octyl adipate, DOA, see Fig. 1. A widely used plasticizer in food (cling) films is DEHA, often in combination with polymers, epoxidized soya-bean oil, etcetera. DEHA also occurs in children toys. We have previously shown that the presence...... of phthalate esters in PVC can be rapidly analyzed by Fourier transform (FT-) Raman spectroscopy excited with a 1064 nm laser. Here in this project we report a similar study. The aim was to find out whether FT-Raman spectroscopy can be used to determine the presence of adipate esters (AEs) as plasticizers...

  4. Thermogravimetric-Mass Spectrometric Study of the Pyrolysis Behavior of PVC

    Institute of Scientific and Technical Information of China (English)

    SUN Qing-lei; SHI Xin-gang; LIN Yun-liang; ZHU He; WANG Xiao; CHENG Chuan-ge; LIU Jian-hua

    2007-01-01

    The pyrolysis characteristics of PVC were systematically investigated using a Netzschne TG thermo-balance coupled to a quadrupole mass spectrometer. The pyrolysis conditions were 0.1 MPa of Ar, a heating rate of 10 ℃/min and a final temperature of 1000 ℃. Both the thermogravimetric properties and the simultaneous evolution of gaseous products during pyrolysis were studied. The TG/DTG results showed that as the pyrolysis temperature increases the weight loss and weight loss rate of PVC increases. Near 412 ℃ the weight loss rate attained its peak value. At higher temperatures the rate of loss gradually decreases. The gases evolved during thermogravimetric analysis were analyzed by a mass spectrometer, monitoring the relative intensity of HCl, C6H6, light hydrocarbon and chlorine-containing gases. The evolution curves showed that HCl, C6H6, light hydrocarbon and chlorine-containing gases all peak at about 416 ℃. This is consistent with the fact that the weight loss curves also peak at about 412 ℃. The extensive HCl evolution is consistent with the high chlorine content of PVC. The formation of these gases can be explained by considering these reactions: dehydrochlorination, intramolecular cyclization and the addition of HCl to unsaturated hydrocarbons.

  5. Study on application of molten salt oxidation technology (MSO) for PVC wastes treatment

    International Nuclear Information System (INIS)

    Tran Thu Ha; Nguyen Hong Quy; Pham Quoc Ky; Nguyen Quang Long; Vuong Thu Bac; Dang Duc Nhan

    2007-01-01

    The project 'Study on application of molten salt oxidation (MSO) for PVC plastic wastes treatment' aims at three followings: 1) Installation of lab-scale MSO unit with essential compositions builds up foundation for the 2) estimation of waste destruction efficiency of the technology. 3) Based on the results of testing PVC - the chlorinated organic wastes on the lab-scale unit, the ability of the technology application at pilot-scale level will be primary estimated. The adjustment and correction of some compositions in the lab-scale unit theoretically designed during experiment overcame the shortages by design and fabrication such as heat distribution regime, feeding wastes and draining spent salt. These solutions adapt to the technical requirement of operation as well as scientific requirement of the research on MSO process. PVC waste treatment was tested on the MSO lab-scale unit in different conditions of operation temperature, superficial air velocity related to air/oxygen feeding rate, waste feeding rate. The testing results showed that destruction efficiency of chlorine in MSO technology was almost absolute. HCl and Cl 2 emission were insignificant in different operation conditions. HCl and Cl 2 emission depend on resident time and nature of molten salt. However, with inherent attributes of MSO technology emission of CO is not avoided in processing waste treatment. Therefore, finding active solutions for reduction CO emission is essential to complete the technology. The experiments also were carried in conditions of single molten salt (Na 2 CO 3 ) and molten (Na 2 CO 3 - K 2 CO 3 ) eutectic. The comparison of efficiency of these tests gives idea of using molten salt eutectic to reduce operation cost in MSO technology. Based on operation parameters and scientific verification results during experiments, the introductory procedure of waste treatment by MSO process was built up. Thereby, primary estimation of development of the technology in pilot-scale is given

  6. PVC flooring at home and development of asthma among young children in Sweden, a 10-year follow-up.

    Science.gov (United States)

    Shu, H; Jönsson, B A; Larsson, M; Nånberg, E; Bornehag, C-G

    2014-06-01

    The incidence of asthma and allergy has increased throughout the developed world over the past decades. During the same period of time, the use of industrial chemicals such as phthalates, commonly used as plasticizers in polyvinylchloride (PVC) flooring material, has increased. The aim of this study was to investigate whether PVC flooring in the home of children in the age of 1-5 years is associated with the development of asthma in 5- and 10-year follow-up investigations (n = 3228). Dampness in Buildings and Health Study (DBH Study) commenced in 2000 in Värmland, Sweden. The current analyses included subjects who answered all baseline and follow-up questionnaires. Logistic regression analyses were applied to questionnaire results. Children who had PVC floorings in the bedroom at baseline were more likely to develop doctor-diagnosed asthma during the following 10-year period when compared with children living without. There were indications that PVC flooring in the parents' bedrooms was strongly associated with the new cases of doctor-diagnosed asthma when compared with child's bedroom. Our results suggest that PVC flooring exposure during pregnancy could be a critical period in the development of asthma in children at a later time; prenatal exposure and measurements of phthalate metabolites should be included in the future. This study has found that PVC flooring material in early life was related to incidence of asthma during the following 10 years when compared with other flooring materials and especially when comparing with wood flooring type.The study has further indicated that PVC flooring in the parents’ bedroom (proxy for prenatal exposure) was more associated with the development of asthma than PVC in the child’s bedroom was. Our results suggest that PVC flooring exposure during pregnancy could be a critical period in the development of asthma in children at a later time. In future prospective cohort study, prenatal exposure and measurements of

  7. A novel ion selective sensor for promethium determination

    International Nuclear Information System (INIS)

    Gupta, Vinod K.; Jain, Rajeev; Hamdan, A.J.; Agarwal, Shilpi; Bharti, Arvind K.

    2010-01-01

    This is a first promethium 145 ion-selective sensor based on the comparative study of two Schiff base ligands (X 1 and X 2 ) as neutral ionophores. Effect of various plasticizers: 2-nitrophenyloctylether (o-NPOE), dibutyl phosphonate (DBP), dioctylphthalate (DOP), tri-(2-ethylhexyl) phosphate (TEHP), dibutyl butylphosphonate (DBBP), chloronaphthalene (CN) and anion excluders: potassium tetrakis (p-chloropheny1) borate (KTpClPB), sodiumtetraphenylborate (NaTPB) and oleic acid (OA) have been studied. The membrane with a composition of ionophore (X 1 /X 2 ):KTpClPB:PVC:o-NPOE (w/w, %) in the ratio of 5:5:30:60 exhibited best performance. The best responsive membrane sensors (8 and 21) exhibited working concentration range of 4.5 x 10 -7 -1.0 x 10 -2 M and 3.5 x 10 -6 -1.0 x 10 -2 M with a detection limits of 3.2 x 10 -7 M and 2.3 x 10 -6 M and Nernstian slopes of 20.0 ± 0.5, 19.5 ± 0.5 mV decade -1 of activity, respectively. The sensor no. 8 works satisfactorily in partially non-aqueous media up to 10% (v/v) content of methanol, ethanol and acetonitrile. Analytical application of the proposed sensor has been demonstrated in determination of promethium (III) ions in spiked water samples.

  8. Novel PVC-membrane potentiometric sensors based on a recently synthesized sulfur-containing macrocyclic diamide for Cd2+ ion. Application to flow-injection potentiometry.

    Science.gov (United States)

    Shamsipur, Mojtaba; Dezaki, Abbas Shirmardi; Akhond, Morteza; Sharghi, Hashem; Paziraee, Zahra; Alizadeh, Kamal

    2009-12-30

    A new sulfur-containing macrocyclic diamide, 1,15-diaza-3,4,12,13-dibenzo-5,11-dithia-8-oxa-1,15-(2,6-pyrido)cyclooctadecan-2,14-dione, L, was synthesized, characterized and used as an active component for fabrication of PVC-based polymeric membrane (PME), coated graphite (CGE) and coated silver wire electrodes (CWE) for sensing Cd(2+) ion. The electrodes exhibited linear Nernstian responses to Cd(2+) ion in the concentration range of 3.3 x 10(-6) to 3.3 x 10(-1)M (for PME, LOD=1.2 x 10(-6)M), 2.0 x 10(-7) to 3.3 x 10(-1)M (for CWE, LOD=1.3 x 10(-7)M) and 1.6 x 10(-8) to 1.3 x 10(-1)M (for CGE, LOD=1.0 x 10(-8)M). The CGE was used as a proper detection system in flow-injection potentiometry (FIP) with a linear Nernstian range of 3.2 x 10(-8) to 1.4 x 10(-1)M (LOD=1.3 x 10(-8)M). The optimum pH range was 3.5-7.6. The electrodes revealed fairly good discriminating ability towards Cd(2+) in comparison with a large number of alkali, alkaline earth, transition and heavy metal ions. The electrodes found to be chemically inert, showing a fast response time of <5s, and could be used practically over a period of about 2-3 months. The practical utility of the proposed system has also been reported.

  9. Selective electrochemical sensor for copper (II) ion based on chelating ionophores

    International Nuclear Information System (INIS)

    Singh, Ashok Kumar; Mehtab, Sameena; Jain, Ajay Kumar

    2006-01-01

    Plasticized membranes using 3-(2-pyridinyl)-2H-pyrido[1,2,-a]-1,3,5-triazine-2,4(3H)-dithione (L 1 ) and acetoacetanilide (L 2 ) have been prepared and explored as Cu 2+ -selective sensors. Effect of various plasticizers, viz. chloronaphthalene (China), benzyl acetate (BA), o-nitrophenyloctyl ether (o-NPOE), and anion excluders, sodium tetraphenylborate (NaTPB) and oleic acid (OA) was studied in detail and improved performance was observed at several instances. Optimum performance was observed with dithione derivative (L 1 ) having a membrane composition of L 1 (5):PVC (120):o-NPOE (240):OA (10). The sensor works satisfactorily in the concentration range 5.0 x 10 -8 to 1.0 x 10 -2 M (detection limit 4.0 x 10 -8 M) with a Nernstian slope of 29.5 mV decade -1 of activity. Wide pH range (3.0-9.5), fast response time (12 s), non-aqueous tolerance (up to 20%) and adequate shelf life (4 months) indicate the vital utility of the proposed sensor. The potentiometric selectivity coefficient values as determined by match potential method (MPM) indicate good response for Cu 2+ in presence of interfering ions. The proposed electrode comparatively shows good selectivity with respect to alkali, alkaline earth, transition and some rare earth metals ions. The electrode was used for the determination of copper in different milk powder, water samples and as indicator electrode in potentiometric titration of copper ion with EDTA

  10. Synthesis and characterization of Zn-doped MgAl-layered double hydroxide nanoparticles as PVC heat stabilizer

    International Nuclear Information System (INIS)

    Wang, Gongling; Yang, Mei; Li, Zhiwen; Lin, Kaifeng; Jin, Quan; Xing, Chaojian; Hu, Zhudong; Wang, Dan

    2013-01-01

    Zn-doped MgAl-layered double hydroxides (LDHs) with M 2+ /M 3+ = 2 and different molar ratios of Mg/Zn have been synthesized by modified homogeneous co-precipitation method and characterized by powder X-ray diffraction, Transmission electron microscopy, Fourier transform infrared spectrum and thermogravimetry, and differential thermal analysis techniques. The thermal stabilizing effects of different LDHs on PVC were studied by Congo red test and thermal aging test. All of the nanoparticles show plate-like morphology and the average diameter of particles is around 90 nm. Results show that the introduction of Zn increased the average bond length and area of the layers of LDHs, therefore enhanced the adsorption ability on HCl gas which was generated during degradation of PVC to improve the thermal stability of PVC. LDHs with molar ratio of Mg/Zn = 1.0 shows the best thermal stabilizing effect on PVC

  11. Synthesis and characterization of Zn-doped MgAl-layered double hydroxide nanoparticles as PVC heat stabilizer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Gongling; Yang, Mei [Chinese Academy of Sciences, State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering (China); Li, Zhiwen; Lin, Kaifeng [Harbin Institute of Technology, Academy of Fundamental Interdisciplinary Sciences (China); Jin, Quan; Xing, Chaojian; Hu, Zhudong [Chinese Academy of Sciences, State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering (China); Wang, Dan, E-mail: danwang@mail.ipe.ac.cn [Harbin Institute of Technology, Academy of Fundamental Interdisciplinary Sciences (China)

    2013-09-15

    Zn-doped MgAl-layered double hydroxides (LDHs) with M{sup 2+}/M{sup 3+} = 2 and different molar ratios of Mg/Zn have been synthesized by modified homogeneous co-precipitation method and characterized by powder X-ray diffraction, Transmission electron microscopy, Fourier transform infrared spectrum and thermogravimetry, and differential thermal analysis techniques. The thermal stabilizing effects of different LDHs on PVC were studied by Congo red test and thermal aging test. All of the nanoparticles show plate-like morphology and the average diameter of particles is around 90 nm. Results show that the introduction of Zn increased the average bond length and area of the layers of LDHs, therefore enhanced the adsorption ability on HCl gas which was generated during degradation of PVC to improve the thermal stability of PVC. LDHs with molar ratio of Mg/Zn = 1.0 shows the best thermal stabilizing effect on PVC.

  12. Platelet storage in Fresenius/NPBI polyolefin and BTHC-PVC bags: a direct comparison.

    Science.gov (United States)

    Hornsey, V S; McColl, K; Drummond, O; Macgregor, I R; Prowse, C V

    2008-08-01

    New platelet storage systems, such as changes in the plastic of the storage bags, require validation. In this study, pooled buffy coat platelets stored in Fresenius/NPBI polyolefin bags were compared with those stored in Fresenius/NPBI butyryl-trihexyl citrate (BTHC) plasticized polyvinyl chloride (PVC). The CompoSelect thrombocyte polishing filter system (1000 mL polyolefin bag) and the CompoStop F730 system (1300 mL BTHC-PVC bag) were used to prepare paired, plasma-suspended, buffy coat platelet concentrates. Samples were taken up to day 7 for in vitro analysis. In a separate experiment, 12 units were prepared using the CompoStop F730 system and samples taken after leucofiltration for FXIIa assay. By day 7, platelet concentrates stored in BTHC-PVC demonstrated significantly higher pH levels (7.32 +/- 0.05 vs. 7.26 +/- 0.05) and a greater degree of cell lysis as shown by increased lactate dehydrogenase levels (497 +/- 107 vs. 392 +/- 81 U L(-1)). The supernatants contained higher concentrations of soluble P-selectin and the chemokine 'regulated on activation, normal T-cell expressed and presumably secreted', which are released from the alpha-granules during activation. The ATP concentrations were significantly lower in BTHC-PVC. Platelet counts, mean platelet volume and hypotonic shock response were similar for both bags. FXIIa antigen concentrations were 0.6 +/- 0.2 ng mL(-1) indicating that activation of the contact factor pathway had not occurred. Although the CompoStop F730 leucoreduction filter did not activate the contact system, platelets stored in 100% plasma in BTHC-PVC bags demonstrated different in vitro characteristics from those stored in polyolefin. Further work is required to demonstrate whether these differences will affect in vivo recovery and survival.

  13. Investigation of dielectric behavior of the PVC/BaTiO3 composite in low-frequencies

    Science.gov (United States)

    Berrag, A.; Belkhiat, S.; Madani, L.

    2018-04-01

    Polyvinyl chloride (PVC) is widely used as insulator in electrical engineering especially as cable insulation sheaths. In order to improve the dielectric properties, polymers are mixed with ceramics. In this paper, PVC composites with different weight percentages 2 wt.%, 5 wt.%, 8 wt.% and 10 wt.% were prepared and investigated. Loss index (𝜀″) and dielectric constant (𝜀‧) have been measured using an impedance analyzer RLC. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) equipped with energy dispersive X-ray (EDX) have been used as characterization techniques. The incorporation of BaTiO3 does not modify the crystallinity and the morphology of the PVC but reduces the space charges, therefore the dielectric losses. The frequency response analysis has been followed in the frequency ranges (20-140 Hz and 115-1 MHz). Relaxation frequencies have been evaluated in each frequency range. Experimental measurements have been validated using Cole-Cole’s model. Experimental results show well that BaTiO3 as a filler improves the dielectric properties of PVC.

  14. All-Solid-State, PVC Membrane, and Carbon Paste Ion-Selective Electrodes for Determination of Donepezil Hydrochloride in Pharmaceutical Formulation.

    Science.gov (United States)

    Khamees, Nesreen; Mohamed, Tagreed Abdel-Fattah; Derar, Abeer Rashad; Aziz, Azza

    2017-09-01

    All-solid-state, polyvinyl chloride (PVC) membrane, and carbon paste potentiometric ion-selective electrodes (ISEs) were proposed for the determination of donepezil hydrochloride (DON) in the drug substance and a pharmaceutical formulation. The potentiometric response toward DON was based on the existence of donepezil-tetraphenyl borate (DON-TPB) in a PVC membrane or a carbon paste in the presence of dioctylphthalate. In contrast, the solid-state electrode was prepared by direct incorporation of DON-TPB into a commercial nail varnish without external additives. The electrodes exhibited Nernstian slopes of 55.0, 57.0, and 53.0 mV/decade over the concentration ranges of 1 × 10-5 to 1 × 10-3, 1 × 10-4 to 10-2, and 1 × 10-4 to 5 × 10-3 for the solid-state, PVC membrane, and carbon paste electrodes, respectively. The response of the electrodes is independent of pH in the range of 2-≤8. The electrodes showed good selectivity for DON with respect to a number of inorganic cations and amino acids. The electrodes were used for the determination of DON in pure solution and in pharmaceutical tablets with high accuracy (±2%) and precision (RSD ≤2%). The solid-state electrode is simple, economical, and rapid when compared to the PVC membrane and carbon paste electrodes.

  15. Model-based performance and energy analyses of reverse osmosis to reuse wastewater in a PVC production site.

    Science.gov (United States)

    Hu, Kang; Fiedler, Thorsten; Blanco, Laura; Geissen, Sven-Uwe; Zander, Simon; Prieto, David; Blanco, Angeles; Negro, Carlos; Swinnen, Nathalie

    2017-11-10

    A pilot-scale reverse osmosis (RO) followed behind a membrane bioreactor (MBR) was developed for the desalination to reuse wastewater in a PVC production site. The solution-diffusion-film model (SDFM) based on the solution-diffusion model (SDM) and the film theory was proposed to describe rejections of electrolyte mixtures in the MBR effluent which consists of dominant ions (Na + and Cl - ) and several trace ions (Ca 2+ , Mg 2+ , K + and SO 4 2- ). The universal global optimisation method was used to estimate the ion permeability coefficients (B) and mass transfer coefficients (K) in SDFM. Then, the membrane performance was evaluated based on the estimated parameters which demonstrated that the theoretical simulations were in line with the experimental results for the dominant ions. Moreover, an energy analysis model with the consideration of limitation imposed by the thermodynamic restriction was proposed to analyse the specific energy consumption of the pilot-scale RO system in various scenarios.

  16. Fuzzy-Based Sensor Fusion for Cognitive Radio-Based Vehicular Ad Hoc and Sensor Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Jalil Piran

    2015-01-01

    Full Text Available In wireless sensor networks, sensor fusion is employed to integrate the acquired data from diverse sensors to provide a unified interpretation. The best and most salient advantage of sensor fusion is to obtain high-level information in both statistical and definitive aspects, which cannot be attained by a single sensor. In this paper, we propose a novel sensor fusion technique based on fuzzy theory for our earlier proposed Cognitive Radio-based Vehicular Ad Hoc and Sensor Networks (CR-VASNET. In the proposed technique, we considered four input sensor readings (antecedents and one output (consequent. The employed mobile nodes in CR-VASNET are supposed to be equipped with diverse sensors, which cater to our antecedent variables, for example, The Jerk, Collision Intensity, and Temperature and Inclination Degree. Crash_Severity is considered as the consequent variable. The processing and fusion of the diverse sensory signals are carried out by fuzzy logic scenario. Accuracy and reliability of the proposed protocol, demonstrated by the simulation results, introduce it as an applicable system to be employed to reduce the causalities rate of the vehicles’ crashes.

  17. Residual lifetime assessment of uPVC gas pipes

    NARCIS (Netherlands)

    Visser, H.A.

    2010-01-01

    The Dutch gas distribution network consists of about 20% (22,500 km) of unplasticised poly(vinyl chloride) (uPVC) pipes, most of which have been installed from the mid-sixties up to the mid-seventies of the previous century and have been in service ever since. In the next decade the specified

  18. In vitro quality of apheresis platelets divided into paediatric-sized units and stored in PVC bags plasticised with TOTM, BTHC or DINCH.

    Science.gov (United States)

    Bashir, S; Meli, A; Cardigan, R

    2018-04-11

    Two of the predictive factors of the quality of small volumes of platelets suitable for paediatric use are bag size and material. This study evaluated the storage properties of paediatric platelet aliquots in TOTM-, BTHC- or DINCH-PVC bags. (i) Three apheresis platelet concentrates (PC) were pooled and split into three units. One was retained as an adult unit (control; polyolefin bag). The second and third units were split into four MacoPharma TOTM-PVC and BTHC-PVC paediatric bags, respectively. (ii) Two apheresis PC were pooled and split into two units. One PC was retained as an adult unit, and the other was split into four Fresenius DINCH-PVC paediatric bags. Testing was performed on storage for pH, blood gases, hypotonic shock response, soluble CD62P, LDH, glucose and lactate, ATP, CD62P, CD63, platelet-derived microparticles and annexin V. The volumes, platelet yields and pH of all paediatric units met local specifications. The TOTM-PVC bag showed no worse quality than the adult bag up to day 7 for all parameters studied, and it maintained pH higher than BTHC-PVC and DINCH-PVC over storage. The BTHC-PVC bag was shown to be the most gas permeable; however, it had the highest glucose consumption rates and the highest platelet activation. All bags showed an acceptable in vitro quality. Overall, the TOTM-PVC paediatric bag showed better platelet quality compared to the other storage bags, whereas storage in the BTHC-PVC bag resulted in poorer platelet quality. © 2018 British Blood Transfusion Society.

  19. Aging and characterization of PVC compound used as flat-panel of a low cost solar collector; Envelhecimento e caracterizacao de compostos de PVC usado em placas de coletores solares de baixo custo

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Bruna R.; Pinto, Tatiana T.; Bartoli, Julio R. [Depto. de Tecnologia de Polimeros, Faculdade de Engenharia Quimica/Universidade Estadual de Campinas. FEQ/UNICAMP, SP (Brazil)], e-mail: bartoli@feq.unicamp.br; Fernandes, Elizabeth G. [Tezca P and D Celulas Solares (Brazil)

    2011-07-01

    Regardless the excellent amount of solar irradiation in Brazil, the development and production of solar water heating systems did not reach the low-income families yet. The relatively high cost of conventional solar water heaters is still the main reason to prevent it. The development of a low cost solar water heater (around US$ 200), easy technology, was the scope of previous work. All-plastic solar collector prototypes were developed using unplasticized Poly (vinyl chloride) ceiling panels and tubes, commodities from building engineering. Nevertheless, the main thermal and photo degradation mechanisms for PVC are well known; the unusual application of PVC as solar collector materials should need a specific investigation on environmental aging. This work presents a study on outdoor aging and characterization of PVC flat-plate absorber of solar collectors after 5 years on use. (author)

  20. Spectroscopic analysis of PMMA/PVC blends containing CoCl2

    Directory of Open Access Journals (Sweden)

    N.S. Alghunaim

    2015-01-01

    Full Text Available Composites of polymethyl methacrylate (PMMA and polyvinyl chloride (PVC polymer blend containing different concentrations (⩽10 wt. of cobalt chloride (CoCl2 were prepared by casting techniques. The changes of the structural, spectroscopic, optical and thermal parameters of the samples are studied using different tools. FT-IR spectroscopy confirmed the complexation between the blends and Co+2-ions. The decrease or increase of IR band intensity with some shifts of other bands suggests an interaction and compatibility between PMMA/PVC blends with CoCl2 take place. The Ultra violet and visible (UV/Vis spectra indicated that the presence of band gap energy depends on increasing of CoCl2 contents. The absorption intensity of the samples doped with CoCl2 becomes faint lower than the pure blend. The values of energy gap for direct and indirect transition decreases with the increase of CoCl2 due to the presence of charge transfer between PMMA/PVC and CoCl2. The thermogravimetric analysis (TGA curves for all the samples have the same behavior and more steps of decomposition were observed. The reduction of mass loss for samples containing CoCl2 compared to the pure blend was observed and it was attributed to crosslink formation between the blend and CoCl2.

  1. Selective flotation of PVC using gelatin and lignin alkali.

    Science.gov (United States)

    Yenial, Unzile; Kangal, Olgaç; Güney, Ali

    2013-06-01

    Recycling has become one of the most important issues as a result of increasing waste mass in present day. This is especially important for polymer wastes as they are hard to degenerate in nature. Today, most of the practical methods used for the recycling of waste mass, such as hand sorting, gravity separation, etc., cannot be performed successfully owing to close densities of polymers. Froth flotation can be used successfully and economically for this purpose. The main objective of this study was to investigate the effect of plasticizer reagents and the success of froth flotation at plastic recycling. In this study, lignin alkali and gelatin were used as plasticizer reagents. The effect of these reagents was searched with the parameters of pH, concentration, conditioning and flotation time. In the case of post-consumed polyethylene terephthalate and polyvinyl chloride (PVC), 98.9% purity of PVC was obtained at optimum conditions.

  2. Preparation of Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) Material and its Application to Electrochemical Degradation of Methylene Blue in Sodium Chloride Solution

    Science.gov (United States)

    Riyanto; Prawidha, A. D.

    2018-01-01

    Electrochemical degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode in sodium chloride have been done. The aim of this work was to degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC). Carbon chitosan composite electrode was preparing by Carbon and Chitosan powder and PVC in 4 mL tetrahydrofuran (THF) solvent and swirled flatly to homogeneous followed by drying in an oven at 100 °C for 3 h. The mixture was placed in stainless steel mould and pressed at 10 ton/cm2. Sodium chloride was used electrolyte solution. The effects of the current and electrolysis time were investigated using spectrophotometer UV-Visible. The experimental results showed that the carbon-chitosan composite electrode have higher effect in the electrochemical degradation of methylene blue in sodium chloride. Based on UV-visible spectra analysis shows current and electrolysis time has high effect to degradation of methylene blue in sodium chloride. Chitosan and polyvinyl chloride can strengthen the bond between the carbons so that the material has the high stability and conductivity. As conclusions is Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode have a high electrochemical activity for degradation of methylene blue in sodium chloride.

  3. Effect of radiation on properties of ENR/PVC/SiO{sub 2} membrane

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Nur Farahein Hadina; Abdullah, Ibrahim; Daik, Rusli; Ahmad, Ishak; Jamil, Suzereen; Lazim, Mohammad Azwan Mat; Othaman, Rizafizah [School of Chemical Sciences and Food Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan. Malaysia (Malaysia)

    2015-09-25

    In this study epoxidised natural rubber (ENR)/polyvinyl chloride (PVC) matrix was prepared by melt blending. The matrix was swelled in THF and silica as a filler was introduced to the solution to generate pore formation. The ENR/PVC/10 % SiO{sub 2} membrane was prepared using a casting knife technique. The membrane was irradiated using 2 MeV electron beam accelerator at a dose range of 10-100 kGy. The effect of electron beam irradiation of the membrane was studied by undergo characterization of Scanning electron microscope (SEM) and Fourier transform infra red (FTIR). Morphological studies showed that pores generated in ENR/PVC/10 % SiO{sub 2} membrane increased with the dosage of radiation. While FTIR analysis showed the presence of peak of Si-O-Si asymmetric stretching at 834 cm{sup −1}. There are no significant changes in the functional group before and after radiation.

  4. Fabrication of copper-selective PVC membrane electrode based on newly synthesized copper complex of Schiff base as carrier

    Directory of Open Access Journals (Sweden)

    Sulekh Chandra

    2016-09-01

    Full Text Available The newly synthesized copper(II complex of Schiff base p-hydroxyacetophenone semicarbazone was explored as neutral ionophore for the fabrication of poly(vinylchloride (PVC based membrane electrode selective to Cu(II ions. The electrode shows a Nernstian slope of 29.8 ± 0.3 mV/decade with improved linear range of 1.8 × 10−7 to 1.0 × 10−1 M, comparatively lower detection limit 5.7 × 10−8 M between pH range of 2.0–8.0, giving a relatively fast response within 5s and can be used for at least 16 weeks without any divergence in potential. The selectivity coefficient was calculated using the fixed interference method (FIM. The electrode can also be used in partially non-aqueous media having up to 25% (v/v methanol, ethanol or acetone content with no significant change in the value of slope or working concentration range. It was successfully applied for the direct determination of copper content in water and tea samples with satisfactory results. The electrode has been used in the potentiometric titration of Cu2+ with EDTA.

  5. Molecular Signatures for the PVC Clade (Planctomycetes, Verrucomicrobia, Chlamydiae and Lentisphaerae of Bacteria Provide Insights into their Evolutionary Relationships

    Directory of Open Access Journals (Sweden)

    Radhey S. Gupta

    2012-09-01

    Full Text Available The PVC superphylum is an amalgamation of species from the phyla Planctomycetes, Verrucomicrobia and Chlamydiae, along with the Lentisphaerae, Poribacteria and two other candidate divisions. The diverse species of this superphylum lack any significant marker that differentiates them from other bacteria. Recently, genome sequences for 37 species covering all of the main PVC groups of bacteria have become available. We have used these sequences to construct a phylogenetic tree based upon concatenated sequences for 16 proteins and identify molecular signatures in protein sequences that are specific for the species from these phyla or those providing molecular links among them. Of the useful molecular markers identified in the present work, 6 conserved signature indels (CSIs in the proteins Cyt c oxidase, UvrD helicase, urease and a helicase-domain containing protein are specific for the species from the Verrucomicrobia phylum; three other CSIs in an ABC transporter protein, cobyrinic acid ac-diamide synthase and SpoVG protein are specific for the Planctomycetes species. Additionally, a 3 aa insert in the RpoB protein is uniquely present in all sequenced Chlamydiae, Verrucomicrobia and Lentisphaerae species, providing evidence for the shared ancestry of the species from these three phyla. Lastly, we have also identified a conserved protein of unknown function that is exclusively found in all sequenced species from the phyla Chlamydiae, Verrucomicrobia, Lentisphaerae and Planctomycetes suggesting a specific linkage among them. The absence of this protein in Poribacteria, which branches separately from other members of the PVC clade, indicates that it is not specifically related to the PVC clade of bacteria. The molecular markers described here in addition to clarifying the evolutionary relationships among the PVC clade of bacteria also provide novel tools for their identification and for genetic and biochemical studies on these organisms.

  6. PVC flooring is related to human uptake of phthalates in infants.

    Science.gov (United States)

    Carlstedt, F; Jönsson, B A G; Bornehag, C-G

    2013-02-01

    Polyvinyl chloride (PVC) flooring material contains phthalates, and it has been shown that such materials are important sources for phthalates in indoor dust. Phthalates are suspected endocrine-disrupting chemicals (EDCs). Consecutive infants between 2 and 6 months old and their mothers were invited. A questionnaire about indoor environmental factors and family lifestyle was used. Urinary metabolites of the phthalates diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBzP), and dietylhexyl phthalate (DEHP) were measured in the urine of the children. Of 209 invited children, 110 (52%) participated. Urine samples were obtained from 83 of these. Urine levels of the BBzP metabolite monobenzyl phthalate (MBzP) was significantly higher in infants with PVC flooring in their bedrooms (P flooring material may increase the human uptake of phthalates in infants. Urinary levels of phthalate metabolites during early life are associated with the use of PVC flooring in the bedroom, body area, and the use of infant formula. This study shows that the uptake of phthalates is not only related to oral uptake from, for example, food but also to environmental factors such as building materials. This new information should be considered when designing indoor environment, especially for children. © 2012 John Wiley & Sons A/S.

  7. Discoloration of polyvinyl chloride (PVC) tape as a proxy for water-table depth in peatlands: validation and assessment of seasonal variability

    Science.gov (United States)

    Booth, Robert K.; Hotchkiss, Sara C.; Wilcox, Douglas A.

    2005-01-01

    Summary: 1. Discoloration of polyvinyl chloride (PVC) tape has been used in peatland ecological and hydrological studies as an inexpensive way to monitor changes in water-table depth and reducing conditions. 2. We investigated the relationship between depth of PVC tape discoloration and measured water-table depth at monthly time steps during the growing season within nine kettle peatlands of northern Wisconsin. Our specific objectives were to: (1) determine if PVC discoloration is an accurate method of inferring water-table depth in Sphagnum-dominated kettle peatlands of the region; (2) assess seasonal variability in the accuracy of the method; and (3) determine if systematic differences in accuracy occurred among microhabitats, PVC tape colour and peatlands. 3. Our results indicated that PVC tape discoloration can be used to describe gradients of water-table depth in kettle peatlands. However, accuracy differed among the peatlands studied, and was systematically biased in early spring and late summer/autumn. Regardless of the month when the tape was installed, the highest elevations of PVC tape discoloration showed the strongest correlation with midsummer (around July) water-table depth and average water-table depth during the growing season. 4. The PVC tape discoloration method should be used cautiously when precise estimates are needed of seasonal changes in the water-table.

  8. Practical problems in radiation sterilization of medical devices made from plasticized PVC

    International Nuclear Information System (INIS)

    Beenen, J.H.

    1990-01-01

    The following three methods for sterilizing medical devices made from plasticised PVC are used in the Netherlands. 1. sterilization by steam, steam-air or superheated water. 2. sterilization by electron beam or gamma irradiation. 3. ethylene oxide sterilization. IV-bags, blood bags and other bag types for similar applications made from plasticized PVC are mostly sterilized by steam-air or super heated water, especially when filled or partly filled containers are considered. More complicated products or products with components that cannot resist steam sterilization of 121 0 C are sterilized by ethylene oxide or irradiation. These last two methods also are favoured for sterilizing empty bags where sticking of the surfaces at the sterilization temperature creates a serious handicap. Moreover, steam sterilization may cause a permanent opacity of some plastics. However, we have to add that due to developments in formulations steam sterilization of empty bags is going to be of an increasing importance. proven carcinogenity of the gas ethylene oxide, difficult deaeration and retention of the gas in plasticized PVC has increased the demand for better radiation resistant plastics as an alternative for steam sterilization. (author)

  9. Photoetching of Immobilized TiO2-ENR50-PVC Composite for Improved Photocatalytic Activity

    Directory of Open Access Journals (Sweden)

    M. A. Nawi

    2012-01-01

    Full Text Available Commercially acquired TiO2 photocatalyst (99% anatase powder was mixed with epoxidized natural rubber-50 (ENR50/polyvinyl chloride (PVC blend by ultrasonication and immobilized onto glass plates as TiO2-ENR50-PVC composite via a dip-coating method. Photoetching of the immobilized TiO2-ENR50-PVC composite was investigated under the irradiation of a 45 W compact fluorescent lamp and characterized by chemical oxygen demand (COD analysis, scanning electron microscopy-energy dispersive X-ray (SEM-EDX spectrometry, thermogravimetry analysis (TGA, and fourier transform infrared (FTIR spectroscopy. The BET surface area of the photoetched TiO2 composite was observed to be larger than the original TiO2 powder due to the systematic removal of ENR50 while PVC was retained within the composite. It also exhibited better photocatalytic efficiency than the TiO2 powder in a slurry mode and was highly reproducible and reusable. More than 98% of MB removal was consistently achieved for 10 repeated runs of the photo-etched photocatalyst system. About 93% of the 20 mg L−1 MB was mineralized over a period of 480 min. The presence of SO42−, NO3−, and Cl− anions was detected in the mineralized solution where the solution pH was reduced from 7 to 4.

  10. Optical Fiber Grating based Sensors

    DEFF Research Database (Denmark)

    Michelsen, Susanne

    2003-01-01

    In this thesis differenct optical fiber gratings are used for sensor purposes. If a fiber with a core concentricity error (CCE) is used, a directional dependent bend sensor can be produced. The CCE direction can be determined by means of diffraction. This makes it possible to produce long......-period gratings in a fiber with a CCE direction parallel or perpendicular to the writing direction. The maximal bending sensitivity is independent on the writing direction, but the detailed bending response is different in the two cases. A temperature and strain sensor, based on a long-period grating and two...... sampled gratings, was produced and investigated. It is based on the different temperature and strain response of these gratings. Both a transfer matrix method and an overlap calculation is performed to explain the sensor response. Another type of sensor is based on tuning and modulation of a laser...

  11. Carneiro hidráulico com tubulação de alimentação em aço galvanizado e em PVC Hydraulic ram pump perfomance with PVC and steel pipes

    Directory of Open Access Journals (Sweden)

    Caroline Abate

    2002-03-01

    Full Text Available A recente crise da energia convencional tem ocasionado a exploração de fontes alternativas de energia. O bombeamento de água utilizando carneiro hidráulico é amplamente empregado em propriedades onde a energia elétrica é escassa ou inexistente. Procurando dar subsídios técnicos para a utilização do PVC nos sistemas de alimentação de um carneiro hidráulico, foi desenvolvido um experimento com objetivo de avaliar o desempenho de um carneiro hidráulico quando alimentado por uma tubulação de PVC e outra de aço galvanizado, sob três alturas de queda (2,1, 3,8 e 4,7 m. Foi utilizada a equação de D'Aubussion's para a avaliação do rendimento, calculado a partir de leituras de altura de recalque, vazão de escape, vazão de recalque e altura de alimentação. Pode-se conseguir o máximo rendimento com o carneiro hidráulico utilizando-se de tubulação de PVC com até 4,2 m de desnível; além desse valor a tubulação de aço galvanizado é mais eficiente.The recent conventional energy crisis is leading to the exploration of alternative energy sources. The pumping of water using ram pumps is widely used in farms where electric energy is scarce or inexistent. This experiment was carried out to evaluate the performance of an hydraulic ram pump utilizing two kinds of supply pipes (PVC and steel using three different supply heads (2.1, 3.8 and 4.7. Delivery head, delivery discharge, waste discharge and supply head were utilized to calculate the yield of the hydraulic ram by the equation of D'Aubussion. The maximum yield of the hydraulic ram was obtained for the PVC pipe for the 4.2 m head; for heads higher than 4.2 m the steel pipe was more efficient.

  12. MECHANICAL, ELECTRICAL, AND THERMAL PROPERTIES OF MALEIC ANHYDRIDE MODIFIED RICE HUSK FILLED PVC COMPOSITES

    OpenAIRE

    Navin Chand; Bhajan Das Jhod

    2008-01-01

    Unmodified and modified rice husk powder filled PVC composites were prepared having different amounts of rice husk powder. Mechanical, thermal, and electrical properties of these composites were determined. The tensile strength of rice husk powder PVC composites having 0, 10, 20, 30, and 40 weight percent of rice husk powder was found to be 33.9, 19.4, 18.1, 14.6, and 9.5 MPa, respectively. Adding of maleic anhydride- modified rice husk powder improved the tensile strength of rice husk powder...

  13. CMOS image sensor-based implantable glucose sensor using glucose-responsive fluorescent hydrogel.

    Science.gov (United States)

    Tokuda, Takashi; Takahashi, Masayuki; Uejima, Kazuhiro; Masuda, Keita; Kawamura, Toshikazu; Ohta, Yasumi; Motoyama, Mayumi; Noda, Toshihiko; Sasagawa, Kiyotaka; Okitsu, Teru; Takeuchi, Shoji; Ohta, Jun

    2014-11-01

    A CMOS image sensor-based implantable glucose sensor based on an optical-sensing scheme is proposed and experimentally verified. A glucose-responsive fluorescent hydrogel is used as the mediator in the measurement scheme. The wired implantable glucose sensor was realized by integrating a CMOS image sensor, hydrogel, UV light emitting diodes, and an optical filter on a flexible polyimide substrate. Feasibility of the glucose sensor was verified by both in vitro and in vivo experiments.

  14. Stabilizing effect of epoxidized sunflower oil as a secondary stabilizer for Ca/Hg stabilized PVC

    Directory of Open Access Journals (Sweden)

    2008-01-01

    Full Text Available Unsaturated triglyceride oil sunflower was epoxidized and characterized by chemical and spectroscopic methods. Epoxidized sunflower oil (ESO was used as an organic thermal co-stabilizer for rigid poly(vinyl chloride (PVC in the presence of tricalcium dicitrate (Ca3(C6H5O72 and mercury (II acetate (Hg(CH3COO2. The thermo-oxidative degradation of PVC was studied in the presence of these ternary stabilizer systems at 170, 180, 190 and 200°C in N2 atmosphere. The effects of metal carboxylate combination Ca/Hg in the absence and in the presence of epoxidized sunflower oil on static heat treatment of PVC have been studied. The formation of polyene sequences was investigated by UV-visible and FT-IR spectroscopy and by comparing viscosity data obtained in the presence and in the absence of the additives. It was found that the additives retard the rate of degradation and reduce the extent of polymer chain scission associated with the thermal degradation of poly(vinyl chloride. Synergistic effects were found when stabilizer was blended in 50:50 weight ratios with either. It was found that ESO exerted a stabilizing effect on the degradation of PVC. The activation energy for degraded PVC in absence of stabilizers was 38.6 kJ•mol–1 and in the presence of Ca/Hg and Ca/Hg/ESO were 53.3 and 64.7 kJ•mol–1 respectively. In order of compare the efficiency of the epoxidized sunflower oil with these metal soap stabilizers, thermal stabilities were evaluated on the basis of evolved hydrogen chloride determined by conductometry technique and degree of discoloration are discussed.

  15. Recent Advances in Paper-Based Sensors

    Directory of Open Access Journals (Sweden)

    Edith Chow

    2012-08-01

    Full Text Available Paper-based sensors are a new alternative technology for fabricating simple, low-cost, portable and disposable analytical devices for many application areas including clinical diagnosis, food quality control and environmental monitoring. The unique properties of paper which allow passive liquid transport and compatibility with chemicals/biochemicals are the main advantages of using paper as a sensing platform. Depending on the main goal to be achieved in paper-based sensors, the fabrication methods and the analysis techniques can be tuned to fulfill the needs of the end-user. Current paper-based sensors are focused on microfluidic delivery of solution to the detection site whereas more advanced designs involve complex 3-D geometries based on the same microfluidic principles. Although paper-based sensors are very promising, they still suffer from certain limitations such as accuracy and sensitivity. However, it is anticipated that in the future, with advances in fabrication and analytical techniques, that there will be more new and innovative developments in paper-based sensors. These sensors could better meet the current objectives of a viable low-cost and portable device in addition to offering high sensitivity and selectivity, and multiple analyte discrimination. This paper is a review of recent advances in paper-based sensors and covers the following topics: existing fabrication techniques, analytical methods and application areas. Finally, the present challenges and future outlooks are discussed.

  16. Properties of Commercial PVC Films with Respect to Electron Dosimetry

    DEFF Research Database (Denmark)

    Miller, Arne; Liqing, Xie

    The properties of three commercially available polyvinyl chloride (PVC) film supplies and one made without additives were tested with respect to their application as routine dose monitors at electron accelerators. Dose fractionation was found to increase the response and the post-irradiation heat...

  17. Relational-Based Sensor Data Cleansing

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Liu, Xiufeng; Nordbjerg, Finn Ebertsen

    2015-01-01

    cleansing approaches, such as classification, prediction and moving average are not suited for embedded sensor devices, due to the limited storage and processing capabilities. In this paper, we propose a sensor data cleansing approach using the relational-based technologies, including constraints, triggers...... and granularity-based data aggregation. The proposed approach is simple but effective to cleanse different types of dirty data, including delayed data, incomplete data, incorrect data, duplicate data and missing data. We evaluate the proposed strategy to verify its efficiency, effectiveness and adaptability.......Today sensors are widely used in many monitoring applications. Due to some random environmental effects and/or sensing failures, the collected sensor data is typically noisy. Thus, it is critical to cleanse the sensor data before using it to answer queries or conduct data analysis. Popular data...

  18. Composite phase change materials prepared by encapsuling paraffin in PVC macrocapsules

    International Nuclear Information System (INIS)

    Chen, Yingbo; Zhang, Shifeng; Zhang, Qi; Chen, Yusheng; Zhang, Yufeng

    2014-01-01

    Highlights: • PVC macrocapsules coated with SiO 2 were synthesized. • Paraffin was encapsuled in the capsules. • The composite PCM has high heat capacity. • The composite PCM has no surpercooling. - Abstract: A novel phase change material capsules with SiO 2 in their surface was prepared by absorbing paraffin into PVC hollow capsules and by the polycondensation reaction of TEOS in different conditions. X-ray photoelectron spectroscopy (XPS) analysis and scanning electronic microscope (SEM) were used to determine chemical composition and microstructure of the composite capsules, respectively. Enthalpy capacity and thermal stability of the composite capsules are systematically characterized by using differential scanning calorimeter (DSC), thermogravimetric analyzer (TGA) and thermocycling tests. The composite has high heat capacity with good stability and absence of supercooling phenomena

  19. Degradation of polyvinyl chloride (PVC) / hydrolyzed collagen (HC) blends active sludge test.

    Science.gov (United States)

    Agafiţei, Gabriela-Elena; Pascu, Mihaela; Cazacu, Georgeta; Vasile, Cornelia

    2008-01-01

    Biodegradable polymers represent a solution for the environment protection: they decrease the landfill space, by declining the petrochemical sources, and offer also an alternative solution for the recycling. The behavior during degradation in the presence of active sludge of some polyvinyl chloride (PVC) based blends with variable content of hydrolyzed collagen (HC) has been followed. Some samples were subjected to UV irradiation, for 30 hours. The modifications induced in the environment by the polymer systems (pH variation, bacterial composition), as well as the changes of the properties of the blends (weight losses, aspect etc.) were studied. During the first moments of degradation in active sludge, all the samples absorbed water, behavior which favored the biodegradation. The bacteriological analysis of the sludge indicates the presence of some microbiological species. Generally, the populations of microorganisms decrease, excepting the sulphito-reducing anaerobic bacteria, the actinomycetes and other anaerobic bacteria. PVC/HC blends are degraded with a significant rate in active sewage sludge. More susceptible for the degradation are the UV irradiated blends. After the migration of the components with a small molecular mass in the environment, the natural polymer is degraded. The degradation effect increases with the content in the natural polymer.

  20. Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters.

    Science.gov (United States)

    Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva

    2014-01-01

    Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

  1. Print Quality of Ink Jet Printed PVC Foils

    Directory of Open Access Journals (Sweden)

    Nemanja Kašiković

    2015-09-01

    Full Text Available Digital printing technique is used for a wide variety of substrates, one of which are PVC foils. Samples used in this research were printed by digital ink jet printing technique using Mimaki JV22 printing machine and J-Eco Subly Nano inks. As printing substrates, two different types of materials were used (ORACAL 640 - Print Vinyl and LG Hausys LP2712. A test card consisting of fields of CMYK colours was created and printed, varying the number of ink layers applied. Samples were exposed to light after the printing process. Spectrophotometric measurements were conducted before and after the light treatment. Based on spectrophotometricaly obtained data, colour differences ΔE2000 were calculated. Results showed that increasing number of layers, as well as the right choice of substrates, can improve the behaviour of printed product during exploitation.

  2. Selective separation of virgin and post-consumer polymers (PET and PVC) by flotation method

    International Nuclear Information System (INIS)

    Burat, Firat; Gueney, Ali; Olgac Kangal, M.

    2009-01-01

    More and more polymer wastes are generated by industry and householders today. Recycling is an important process to reduce the amount of waste resulting from human activities. Currently, recycling technologies use relatively homogeneous polymers because hand-sorting waste is costly. Many promising technologies are being investigated for separating mixed thermoplastics, but they are still uneconomical and unreliable. At present, most waste polymers cause serious environmental problems. Burning polymers for recycling is not practiced since poisonous gases are released during the burning process. Particularly, polyvinyl chloride (PVC) materials among waste polymers generate hazardous HCl gas, dioxins containing Cl, etc., which lead to air pollution and shorten the life of the incinerator. In addition, they make other polymers difficult to recycle. Both polyethylene terephthalate (PET) and PVC have densities of 1.30-1.35 g/cm 3 and cannot be separated using conventional gravity separation techniques. For this reason, polymer recycling needs new techniques. Among these techniques, froth flotation, which is also used in mineral processing, can be useful because of its low cost and simplicity. The main objective of this research is to recycle PET and PVC selectively from post-consumer polymer wastes and virgin polymers by using froth flotation. According to the results, all PVC particles were floated with 98.8% efficiency in virgin polymer separation while PET particles were obtained with 99.7% purity and 57.0% efficiency in post-consumer polymer separation.

  3. PVC--as flooring material--and its association with incident asthma in a Swedish child cohort study.

    Science.gov (United States)

    Larsson, M; Hägerhed-Engman, L; Kolarik, B; James, P; Lundin, F; Janson, S; Sundell, J; Bornehag, C G

    2010-12-01

    The Dampness in Buildings and Health study (DBH) started in the year 2000 in Värmland, Sweden, with a baseline questionnaire sent to all children (n = 14,077) aged 1-6. Five years later, a follow-up questionnaire was sent to the children who were 1-3 years at baseline. A total of 4779 children participated in both the baseline and the follow-up studies and constitute the study population in this cohort study. The aim of this study was to examine the association between exposure to PVC-flooring in the child's and parent's bedroom in homes of children aged 1-3 and the incidence of asthma, rhinitis, and eczema during the following 5-year period. Adjusted analyses showed that the incidence of asthma among children was associated with PVC-flooring in the child's bedroom (AOR 1.52; 95% CI 0.99-2.35) and in the parent's bedroom (1.46; 0.96-2.23). The found risks were on borderline of significance and should therefore be interpreted with caution. There was further a positive relationship between the number of rooms with PVC-flooring and the cumulative incidence of asthma. PVC-flooring was found to be a stronger risk factor for incident asthma in multifamily homes when compared with single-family houses and in smoking families compared with non-smoking families and in women. These longitudinal data from the DBH study found an association between the presence of PVC-flooring in the home and incident asthma in children. However, earlier results from the DBH study have shown that PVC-flooring is one important source for phthalates in indoor dust, and exposure to such phthalates was found to be associated with asthma and allergy among children. This emphasizes the need for prospective studies that focus on the importance of prenatal and neonatal exposure to phthalates in the development of asthma and allergy in children. © 2010 John Wiley & Sons A/S.

  4. The influence of soil and landfill leachate microorganisms in the degradation of PVC/PCL films cast from DMF

    Directory of Open Access Journals (Sweden)

    Adriana de Campos

    2012-01-01

    Full Text Available While the use of plastics continues to increase in our daily lives in a growing range products, these materials are very persistent in the environment. The blending of aliphatic polyesters with other thermoplastic polymers is a profitable way of producing materials with changed physical properties and biodegradability, which can facilitate microbial adhesion to the polymer matrix and help to reduce (post-consumer degradation time of these materials in landfills. This study was an investigation of the biodegradation of films of blends of poly(vinyl chloride (PVC and poly(ε-caprolactone (PCL by soil microorganisms and leachate, by means of respirometry, infrared absorption spectroscopy (FTIR, differential calorimetry scanning (DSC, scanning electron microscopy (SEM, contact angle and weight loss. The results showed that in the soil, the films suffered oxidative biodegradation. The PCL promoted degradation of the PVC in the film of PVC/PCL and the PVC inhibited the rapid degradation of the PCL.

  5. Electrical and spectroscopic characterization of polyaniline-polyvinyl chloride (PANI-PVC) blends doped with sodium thiosulphate

    International Nuclear Information System (INIS)

    Ameen, Sadia; Ali, Vazid; Zulfequar, M.; Mazharul Haq, M.; Husain, M.

    2008-01-01

    Polyaniline is doped with sodium thiosulphate in aqueous tetrahydrofuran (THF) and the blended films have been prepared by changing the amount of doped polyaniline (PANI) in the fixed amount of polyvinyl chloride (PVC). The electrical conductivity of various samples of polyaniline-polyvinyl chloride (PANI-PVC) blends has been studied to see the effect of dopant in the temperature range 300-400 K. Mott's parameters are used to explain the conduction mechanism. Different parameters such as pre-exponential factor (σ 0 ), activation energy (ΔE) and T 0 have also been calculated to see the effect of chemical doping. The crystallinity of the blends is explained on the basis of T 0 . The calculated values of T 0 show that crystallinity increases with an increase of doped PANI in PANI-PVC blends. Fourier transform-infrared (FTIR) spectroscopy is done to explore the nature and interaction of dopant into the polymeric chain

  6. All-plastic fiber-based pressure sensor

    DEFF Research Database (Denmark)

    Bundalo, Ivan-Lazar; Lwin, Richard; Leon-Saval, Sergio

    2016-01-01

    We present a feasibility study and a prototype of an all-plastic fiber-based pressure sensor. The sensor is based on long period gratings inscribed for the first time to the best of our knowledge by a CO2 laser in polymethyl methacrylate (PMMA) microstructured fibers and coupled to a pod......-like transducer that converts pressure to strain. The sensor prototype was characterized for pressures up to 150 mbars, and various parameters related to its construction were also characterized in order to enhance sensitivity. We consider this sensor in the context of future applications in endoscopic pressure...... sensors....

  7. Gas Sensors Based on Electrodeposited Polymers

    Directory of Open Access Journals (Sweden)

    Boris Lakard

    2015-07-01

    Full Text Available Electrochemically deposited polymers, also called “synthetic metals”, have emerged as potential candidates for chemical sensing due to their interesting and tunable chemical, electrical, and structural properties. In particular, most of these polymers (including polypyrrole, polyaniline, polythiophene and their derivatives can be used as the sensitive layer of conductimetric gas sensors because of their conducting properties. An important advantage of polymer-based gas sensors is their efficiency at room temperature. This characteristic is interesting since most of the commercially-available sensors, usually based on metal oxides, work at high temperatures (300–400 °C. Consequently, polymer-based gas sensors are playing a growing role in the improvement of public health and environment control because they can lead to gas sensors operating with rapid detection, high sensitivity, small size, and specificity in atmospheric conditions. In this review, the recent advances in electrodeposited polymer-based gas sensors are summarized and discussed. It is shown that the sensing characteristics of electrodeposited polymers can be improved by chemical functionalization, nanostructuration, or mixing with other functional materials to form composites or hybrid materials.

  8. Study on the interactions PVC/plasticizers by NMR

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, Maria I.B.; Monteiro, Elisabeth E.C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Macromoleculas; Harris, Robin [Durham Univ. (United Kingdom). Dept. of Chemistry

    1992-12-31

    The nature of the interactions between PVC and plasticizers as di-butyl phthalate and di-2-ethyl-hexyl phthalate can be investigated using proton/carbon-13 NMR techniques. The measurements of T{sub 1} for protons and carbon-13 and T{sub 1} P for protons can provide a good source of information about the complex behaviour for those two systems which were investigated. (author) 14 refs., 5 figs., 1 tab.

  9. New polyvinyl chloride (PVC) nanocomposite consisting of aromatic polyamide and chitosan modified ZnO nanoparticles with enhanced thermal stability, low heat release rate and improved mechanical properties

    Science.gov (United States)

    Hajibeygi, Mohsen; Maleki, Mahdiye; Shabanian, Meisam; Ducos, Franck; Vahabi, Henri

    2018-05-01

    New ternary nanocomposite systems containing polylvinyl chloride (PVC), chitosan modified ZnO (CMZN) nanoparticles and new synthesized polyamide (PA) were designed and prepared by solution casting method. As a potential reinforcement, CMZN was used in PVC system combined with and without PA. Morphology, mechanical, thermal and combustion properties of the all PVC systems were studied. In the presence of the CMZN, PA showed a synergistic effect on improvement of the all investigated properties of PVC. The 5 mass% loss temperature (T5) was increased from 195 °C to 243 °C in PVC/CMZN-PA nanocomposite containing 1 mass% of each PA and CMZN (PZP 2). The peak of heat release rate was decreased from 131 W/g for PVC to 104 W/g for PVC/CMZN-PA nanocomposite containing 3 mass% of each PA and CMZN (PZP 6). According to the tensile tests, compared to the neat PVC, the tensile strength was increased from 35.4 to 53.4 MPa for PZP 6.

  10. Model-Based Method for Sensor Validation

    Science.gov (United States)

    Vatan, Farrokh

    2012-01-01

    Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in situ platforms. One of NASA s key mission requirements is robust state estimation. Sensing, using a wide range of sensors and sensor fusion approaches, plays a central role in robust state estimation, and there is a need to diagnose sensor failure as well as component failure. Sensor validation can be considered to be part of the larger effort of improving reliability and safety. The standard methods for solving the sensor validation problem are based on probabilistic analysis of the system, from which the method based on Bayesian networks is most popular. Therefore, these methods can only predict the most probable faulty sensors, which are subject to the initial probabilities defined for the failures. The method developed in this work is based on a model-based approach and provides the faulty sensors (if any), which can be logically inferred from the model of the system and the sensor readings (observations). The method is also more suitable for the systems when it is hard, or even impossible, to find the probability functions of the system. The method starts by a new mathematical description of the problem and develops a very efficient and systematic algorithm for its solution. The method builds on the concepts of analytical redundant relations (ARRs).

  11. Cyclic Voltammetry of Biopolymer Heparin at PVC Plasticized Liquid Membrane

    Czech Academy of Sciences Publication Activity Database

    Samec, Zdeněk; Trojánek, Antonín; Langmaier, Jan; Samcová, E.

    2003-01-01

    Roč. 5, - (2003), s. 867-870 ISSN 1388-2481 R&D Projects: GA ČR GA203/04/0424 Institutional research plan: CEZ:AV0Z4040901 Keywords : cyclic voltammetry * PVC plasticized liquit membrane * heparin Subject RIV: CG - Electrochemistry Impact factor: 2.300, year: 2003

  12. Desenvolvimento de PVC reforçado com resíduos de Pinus para substituir madeira convencional em diversas aplicações Development of PVC/wood composites for the replacement of conventional wood products

    Directory of Open Access Journals (Sweden)

    Antonio Rodolfo Jr.

    2006-03-01

    Full Text Available Este trabalho avalia a viabilidade técnica da obtenção de compósitos lignocelulósicos de PVC, utilizando-se resíduo de Pinus elliottii e Pinus taeda como carga reforçativa. Foi desenvolvido um processo simples e economicamente viável de tratamento de resíduos industriais desta madeira, processo este baseado na secagem e revestimento das partículas com lubrificantes funcionais e agentes de acoplamento utilizados como aditivos na indústria do PVC, bem como no uso de equipamentos tradicionais da indústria de processamento deste termoplástico. Foram avaliados os efeitos da incorporação da farinha de madeira em concentrações variáveis e do tipo de agente de tratamento superficial utilizado na processabilidade do composto de PVC, bem como em propriedades finais do compósito. Os resultados mostram que o desenvolvimento deste tipo de material compósito é uma alternativa viável para a substituição da madeira convencional em diversas aplicações.This work evaluates the technical viability of lignocellulosic vinyl composites, using residues of Pinus elliottii and Pinus taeda as the reinforcement fiber. A simple and economically viable process for the treatment of these industrial residues was developed. The process includes sieving, drying and treating the wood particles. Treatment is made with functional lubricants and coupling agents used as additives in the PVC industry. Extrusion was performed using traditional equipment available in the Brazilian PVC processing industry. The effect on the processability of the variable concentrations of the residues incorporated and the type of agent used for the treatment had been evaluated, as well as in the final properties of the composite. The results show that the development of this kind of composite material is a viable alternative for the substitution of conventional wood in diverse applications.

  13. Resistance of particleboard panels made of agricultural residues and bonded with synthetic resins or PVC plastic to wood-rotting fungi

    Directory of Open Access Journals (Sweden)

    Divino Eterno Teixeira

    2009-12-01

    Full Text Available This study aims to evaluate the resistance of three types of particleboard panel to biodeterioration, two of which bonded with synthetic resins and one bonded with PVC plastic. Composite panels were made using sugar cane straw particles as raw material which were bonded together with urea-formaldehyde (UF, tannin-formaldehyde (TANI and PVC plastic (PVC resins. Decay tests were performed following procedures outlined in the ASTM D2017-81/1994 standard, whereby sample specimens were subjected to attack by white rot fungus Trametes versicolor and brown rot fungus Gloeophyllum trabeum using pine (Pinus sp. and embaúba (Cecropia sp. as reference timber. Panels bonded with PVC resin were rated ‘resistant’ to attack by both fungi while those bonded with UF and TANI resins were rated ‘slightly resistant’ to their attack.

  14. Performance of UWB Array-Based Radar Sensor in a Multi-Sensor Vehicle-Based Suit for Landmine Detection

    NARCIS (Netherlands)

    Yarovoy, A.; Savelyev, T.; Zhuge, X.; Aubry, P.; Ligthart, L.; Schavemaker, J.G.M.; Tettelaar, P.; Breejen, E. de

    2008-01-01

    In this paper, integration of an UWB array-based timedomain radar sensor in a vehicle-mounted multi-sensor system for landmine detection is described. Dedicated real-time signal processing algorithms are developed to compute the radar sensor confidence map which is used for sensor fusion.

  15. Karakteristik sifat mekanik, ketahanan api dan pembakaran, dan morfologi nanokomposit campuran PVC dan LDPE

    Directory of Open Access Journals (Sweden)

    Arum Yuniari

    2014-06-01

    Full Text Available The purpose of the study was to determine the effect of addition of low density polyethylene (LDPE and flame retardant on mechanical properties, resistant to fire and burning and morphology from the mixture of polyvinyl chloride (PVC, LDPE, flame retardant, and nanoprecipitated calcium carbonate (NPCC as filler. The materials were mixed in laboplastomill at 215 ºC, torque speed 50 rpm, for 10 minutes. Nanocomposite was prepared by PVC/LDPE variations of 100/15; 100/20; 100/25; and 100/30 phr and flame retardant variations of 30 and 35 phr. The results showed that the hihger of LDPE in nanocomposite increased the hardness and impact resistance, however, it decreased the tensile strength, elongation at break, and density. Addition of flame retardant to the nanocomposites showed good resistance to fire and burning, and optimum mechanical properties were found in using of 35 phr flame retardant.The morphology of the nanocomposite, were observed by Scanning Electron Microscope (SEM confirmed that homogeneous mixture of LDPE dispersed in the PVC matrix.

  16. Sensitivity Enhancement of FBG-Based Strain Sensor.

    Science.gov (United States)

    Li, Ruiya; Chen, Yiyang; Tan, Yuegang; Zhou, Zude; Li, Tianliang; Mao, Jian

    2018-05-17

    A novel fiber Bragg grating (FBG)-based strain sensor with a high-sensitivity is presented in this paper. The proposed FBG-based strain sensor enhances sensitivity by pasting the FBG on a substrate with a lever structure. This typical mechanical configuration mechanically amplifies the strain of the FBG to enhance overall sensitivity. As this mechanical configuration has a high stiffness, the proposed sensor can achieve a high resonant frequency and a wide dynamic working range. The sensing principle is presented, and the corresponding theoretical model is derived and validated. Experimental results demonstrate that the developed FBG-based strain sensor achieves an enhanced strain sensitivity of 6.2 pm/με, which is consistent with the theoretical analysis result. The strain sensitivity of the developed sensor is 5.2 times of the strain sensitivity of a bare fiber Bragg grating strain sensor. The dynamic characteristics of this sensor are investigated through the finite element method (FEM) and experimental tests. The developed sensor exhibits an excellent strain-sensitivity-enhancing property in a wide frequency range. The proposed high-sensitivity FBG-based strain sensor can be used for small-amplitude micro-strain measurement in harsh industrial environments.

  17. Chilled water optimization at Beek INEOS PVC Plant : ammonia cycle

    NARCIS (Netherlands)

    Karami Alaghinloo, B.

    2012-01-01

    In BEEK INEOS PVC plant, polymerization takes place in a suspension process in twenty reactors in five lines. As the reaction is exothermic, a 17MW chilled water unit (CWU) removing heat from reactors which are producing different grades in batch processes. The objective of the project was to

  18. Excellent impact performance of PVC pipeline materials in gas distribution networks after many years of service (CD-rom)

    NARCIS (Netherlands)

    Visser, Roy; Hermkens, R.M.J.; Wolters, Mannes; Weller, J.; Warnet, Laurent; Beckervordersandforth, C.; Verberg, G.H.B.; Kramer, M.

    2008-01-01

    It has been about fifty years ago since the first unplasticized poly(vinyl chloride) (uPVC) pipes were installed for use in gas distribution purposes. Currently, about 22,500 km of uPVC is still in use in the Dutch gas distribution network. The pipes were originally designed for a lifetime of 50

  19. Dosimetry of the JS-6500 industrial irradiator for the irradiation of the PVC graduated flasks; Dosimetria del irradiador industrial JS-6500 para la irradiacion de probetas de PVC

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda F, A.; Carrasco A, H.; Martinez P, M.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The dosimetry of the JS-6500 AECL irradiator was realized, outside of the industrial transportation rails to know the dose distribution, as well as its dose speed. This one with the intention of exposing to gamma radiation; plastified PVC graduated flasks and evaluating their interweavement or degradation or both. This study of dosimetry was carried out by means of a theoretical and experimental evaluation in air atmosphere. The results allow to know the irradiation conditions of the PVC graduated flasks as well as those results prove that has not a significant difference among the obtained result as theoretical as experimentally due to that the obtained result in the theoretical evaluation is 2.62 KGy/h and the result for the case of the experimental evaluation is 2.74 KGy/h. (Author)

  20. Production of pre-basic potato seed by polyvinyl chloride PVC: articulate gutters hydroponic system

    Directory of Open Access Journals (Sweden)

    Jonny Everson Scherwinski-Pereira

    2009-10-01

    Full Text Available The development of more efficient and productive systems for pre-basic seed potato production would improve the quality of the propagative material used by the potato growers, directly affecting the crop yields. A two-year experiment was carried out to evaluate the potato pre-basic seed production by two types of hydroponic systems (fibrocement tiles and articulated PVC gutters, two cultivars (`Baronesa` and `Eliza` and two types of propagative material (plants coming from in vitro culture and minitubers. The PVC gutters system was highly efficient. When using minitubers, this system reached multiplication rates up to 74 tubers per plant. Minitubers were more productive than in vitro plants, independent of cultivar and hydroponic system utilized.Um experimento realizado por dois anos consecutivos avaliou a produção de sementes pré-básicas de batata por meio de sistemas de cultivo hidropônico. O trabalho testou a combinação de dois sistemas de cultivo (telha de fibrocimento e calhas de PVC articuladas, duas cultivares (Baronesa e Eliza e dois tipos de material propagativo (plântulas oriundas do cultivo in vitro e minitubérculos. O sistema de calhas de PVC foi altamente eficiente. Quando foi utilizado minitubérculos, este sistema alcançou taxas de multiplicação de até 74 tubérculos por planta. De modo geral, o uso de minitubérculos como material propagativo apresentou os melhores resultados de produtividade quando comparada ao material in vitro, independentemente da cultivar e sistemas hidropônicos utilizados.

  1. Model-based Sensor Data Acquisition and Management

    OpenAIRE

    Aggarwal, Charu C.; Sathe, Saket; Papaioannou, Thanasis G.; Jeung, Ho Young; Aberer, Karl

    2012-01-01

    In recent years, due to the proliferation of sensor networks, there has been a genuine need of researching techniques for sensor data acquisition and management. To this end, a large number of techniques have emerged that advocate model-based sensor data acquisition and management. These techniques use mathematical models for performing various, day-to-day tasks involved in managing sensor data. In this chapter, we survey the state-of-the-art techniques for model-based sensor data acquisition...

  2. Resource Discovery in Activity-Based Sensor Networks

    DEFF Research Database (Denmark)

    Bucur, Doina; Bardram, Jakob

    This paper proposes a service discovery protocol for sensor networks that is specifically tailored for use in humancentered pervasive environments. It uses the high-level concept of computational activities (as logical bundles of data and resources) to give sensors in Activity-Based Sensor Networ....... ABSN enhances the generic Extended Zone Routing Protocol with logical sensor grouping and greatly lowers network overhead during the process of discovery, while keeping discovery latency close to optimal.......This paper proposes a service discovery protocol for sensor networks that is specifically tailored for use in humancentered pervasive environments. It uses the high-level concept of computational activities (as logical bundles of data and resources) to give sensors in Activity-Based Sensor Networks...... (ABSNs) knowledge about their usage even at the network layer. ABSN redesigns classical network-level service discovery protocols to include and use this logical structuring of the network for a more practically applicable service discovery scheme. Noting that in practical settings activity-based sensor...

  3. Relational-Based Sensor Data Cleansing

    DEFF Research Database (Denmark)

    Iftikhar, Nadeem; Nordbjerg, Finn Ebertsen

    2015-01-01

    approaches, such as classification, prediction and moving average, are not suited for embedded sensor devices, due to their limit storage and processing capabilities. In this paper, we propose a sensor data cleansing approach using the relational-based technologies, including constraints, triggers...... and granularity-based data aggregation. The proposed approach is simple but effective to cleanse different types of dirty data, including delayed data, incomplete data, incorrect data, duplicate data and missing data. We evaluate the proposed strategy to verify its efficiency and effectiveness.......Today sensors are widely used in many monitoring applications. Due to some random environmental effects and/or sensing failures, the collected sensor data is typically noisy. Thus, it is critical to cleanse the data before using it for answering queries or for data analysis. Popular data cleansing...

  4. Etoricoxib selective sensor based on uracil-5,6-diamino-2-thio hydrochloride as neutral carrier for potentiometric analysis in pharmaceutical preparations

    Directory of Open Access Journals (Sweden)

    Salwa Fares Rassi

    2016-06-01

    Full Text Available A construction and electrochemical behavior of novel potentiometric membrane sensor responsive to the etoricoxib was described. The sensor was based on the ion-pair complex of etoricoxib (ET with Uracil-5,6-diamino-2-thio hydrochloride UDTH (ET-UDTH as exchange sites in a PVC matrix with different plasticizers dibutylphthalate (DBP (electrode B tri-n-butylphosphate (TBP (electrode C, and dioctylphthalate (DOP (electrode A. The electrodes exhibited near-Nernstian response for ET-UDTH over the concentration range 0.051-40.042 mM. The electrode offered significant advantages including long lifetime (about 2 months, excellent stability and reproducibility, good response time (10-25 s, and wide pH working range (pH 5-12. Selectivity coefficients of ET related to a number of interfering cation and some organic compounds were investigated, and there were negligible interference caused by most of the investigated species. The direct determination of 0.5-10 mM of ET showed an average recovery of 99.03-101.75% and a mean relative standard deviation 0.40-1.88. The results were obtained by determination of ET in tablets using the proposed electrodes which were comparable favorably with those obtained by spectrophotometric method

  5. Monitoring a PVC batch process with multivariate statistical process control charts

    NARCIS (Netherlands)

    Tates, A. A.; Louwerse, D. J.; Smilde, A. K.; Koot, G. L. M.; Berndt, H.

    1999-01-01

    Multivariate statistical process control charts (MSPC charts) are developed for the industrial batch production process of poly(vinyl chloride) (PVC). With these MSPC charts different types of abnormal batch behavior were detected on-line. With batch contribution plots, the probable causes of these

  6. Properties of commercial PVC-films with respect to electron dosimetry

    International Nuclear Information System (INIS)

    Miller, A.; Liqing, X.

    1985-05-01

    The properties of three commercially available polyvinyl chloride (PVC) film supplies and one made without additives were tested with respects to their application as routine dose monitors at electron accelerators. Dose fractionation was found to increase the response and the post-irradiation heat treatment was very critical for some of the films. (author)

  7. AN INVESTIGATION OF THE IMPACT OF IMPURITIES ON THE MECHANICAL PROPERTIES OF RECYCLED PVC EXTRUSION PIPES

    OpenAIRE

    Adamu Alhaji Umar; Raji Olalere Fatai

    2007-01-01

    This work studied the effect of using recycled scraps in the production of rigid PVC extrusion pipe. Different formulations with varied percentages of scraps were extruded and various tests carried out on the sample specimen to determine their corresponding mechanical properties. It was finally discovered that among the two sources of scraps, the in-house scraps contained less impurities and blending about 10% of it with virgin PVC material in the production gave improved mechanical propertie...

  8. Monitoring of praseodymium(III) ions in aqueous solutions, soil and sediment samples by a PVC membrane sensor based on a furan-triazole derivative

    Energy Technology Data Exchange (ETDEWEB)

    Pourjavid, Mohammad Reza [Islamic Azad University, Tehran (Iran, Islamic Republic of). Dept. of Medicinal Chemistry. Nuclear Science and Technology Research Institute; Rezaee, Mohammad; Hosseini, Majid Haji [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Razavi, Taherehsadat, E-mail: pourjavid@gmail.com [Research Institute of Petroleum Industry, Tehran (Iran, Islamic Republic of). Instrumental Analysis Dept.

    2012-07-01

    A furan-triazole derivative has been explored as an ionophore for preparation of a highly selective Pr(III) membrane sensor. The proposed sensor exhibits a Nernstian response for Pr(III) activity over a wide concentration range with a detection limit of 5.2 x 10{sup -8}M. Its response is independent of pH of the solution in the range 3.0-8.8 and offers the advantages of fast response time. To investigate the analytical applicability of the sensor, it was applied successfully as an indicator electrode in potentiometric titration of Pr(III) solution and also in the direct and indirect determination of trace Pr(III) ions in some samples. (author)

  9. Armazenamento de atemoias (Annona squamosa x Annona cherimola recobertas com filme PVC

    Directory of Open Access Journals (Sweden)

    P. A. de Souza

    2015-12-01

    Full Text Available A atemoia, assim como todos os frutos climatéricos, apresenta uma elevada perecibilidade, tornando-se importante a adoção de técnicas pós-colheita. Este trabalho teve como objetivo avaliar o armazenamento de atemoias recobertas com filme PVC. Os frutos utilizados foram da variedade ‘Gefner’ apresentando-se em estado de maturação verde-maduro. Estes foram transferidos para o laboratório de Química de Alimentos do IFCE, submetidos à higienização e divididos nos devidos tratamentos. O primeiro tratamento constou no armazenamento de cinco frutos em bandejas de isopor recobertos com filme PVC. O segundo, do recobrimento individual dos frutos em filme PVC, sendo estes acondicionados em bandejas de isopor e os frutos do controle. Estes foram armazenados durante 8 dias. O delineamento utilizado foi o DIC em esquema fatorial 3x4 com quatro repetições de cinco frutos por parcela. A cada tempo de armazenamento foram avaliadas: perda de massa, sólidos solúveis, acidez titulável, Ratio, pH e índice de rachaduras. O uso de filme plástico reduz a perda de massa, porém retarda o amadurecimento de frutos de atemoia. As rachaduras estão diretamente associadas ao amadurecimento dos frutos, ao aumento dos teores de sólidos solúveis e possivelmente a cultivar avaliada. Storage of atemoyas (Annona squamosa x Annona cherimola covered with PVC filmAbstract: The atemoya, as well as all climacteric fruits, is highly perishable, becoming important to adopt post-harvest techniques. This work aimed to evaluate the atemoyas storage covered with plastic wrap. The fruits used were of the variety 'Gefner' presenting itself in a state of green-mature aging. These were transferred to the Food Chemistry Lab IFCE submitted to cleaning and divided in appropriate treatments. The first treatment consisted in five fruit storage in styrofoam trays covered with plastic wrap. The second, the individual coating of the fruits in PVC film, which are packed in

  10. Polymeric matrix membrane sensors for stability-indicating potentiometric determination of oxybutynin hydrochloride and flavoxate hydrochloride urogenital system drugs.

    Science.gov (United States)

    Heba, Mohamed; Ramadan, Nesrin; El-Laithy, Moustafa

    2008-01-01

    Four polyvinyl chloride (PVC) matrix membrane electrodes responsive to 2 drugs affecting the urogenital system--oxybutynin hydrochloride (OX) and flavoxate hydrochloride (FX)--were developed, described, and characterized. A precipitation-based technique with tungstophosphate (TP) and ammonium reineckate (R) anions as electroactive materials in a PVC matrix with an OX cation was used for electrode 1 and 2 fabrication, respectively. Electrode 3 and 4 fabrication was based on use of the precipitation technique of FX cation with tetrakis (4-chlorophenyl) borate and R anions as electroactive materials. Fast and stable Nernstian responses in the range 1 x 10(-2)-1 x 10(-6) M for the 2 drugs over the pH range 5-8 revealed the performance characteristics of these electrodes, which were evaluated according to International Union of Pure and Applied Chemistry recommendations. The method was applied to FX and OX in their pharmaceutical formulations and in human plasma samples. The 4 proposed sensors were found to be specific for the drugs in the presence of up to 60% of their degradation products. Validation of the method according to the quality assurance standards showed suitability of the proposed electrodes for use in the quality control assessment of these drugs. The recoveries for determination of the drugs by the 4 proposed selective electrodes were 99.5 +/- 0.5, 100.0 +/- 0.4, 99.9 +/- 0.4, and 100.1 +/- 0.4% for sensors 1-4, respectively. Statistical comparison between the results obtained by this method and the official method of the drugs was done, and no significant difference found.

  11. A risk-based sensor placement methodology

    International Nuclear Information System (INIS)

    Lee, Ronald W.; Kulesz, James J.

    2008-01-01

    A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors to protect population against the exposure to, and effects of, known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure at standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats detected by sensors placed in prior iterations are removed from consideration in subsequent iterations. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal utility of each additional sensor. This is the fraction of the total risk accounted for by placement of the sensor. Thus, the criteria for halting the iterative process can be the number of sensors available, a threshold marginal utility value, and/or a minimum cumulative utility achieved with all sensors

  12. Model-based sensor diagnosis

    International Nuclear Information System (INIS)

    Milgram, J.; Dormoy, J.L.

    1994-09-01

    Running a nuclear power plant involves monitoring data provided by the installation's sensors. Operators and computerized systems then use these data to establish a diagnostic of the plant. However, the instrumentation system is complex, and is not immune to faults and failures. This paper presents a system for detecting sensor failures using a topological description of the installation and a set of component models. This model of the plant implicitly contains relations between sensor data. These relations must always be checked if all the components are functioning correctly. The failure detection task thus consists of checking these constraints. The constraints are extracted in two stages. Firstly, a qualitative model of their existence is built using structural analysis. Secondly, the models are formally handled according to the results of the structural analysis, in order to establish the constraints on the sensor data. This work constitutes an initial step in extending model-based diagnosis, as the information on which it is based is suspect. This work will be followed by surveillance of the detection system. When the instrumentation is assumed to be sound, the unverified constraints indicate errors on the plant model. (authors). 8 refs., 4 figs

  13. Flame treatment for the selective wetting and separation of PVC and PET.

    Science.gov (United States)

    Pascoe, R D; O'Connell, B

    2003-01-01

    Flame treatment has been used for many years to modify the surface of plastics to allow coatings to be added. The effect of the treatment is to produce hydrophilic species on the surface of the plastic making it water-wettable. The production of hydrophilic plastic surfaces is also required in the selective separation of plastics by froth flotation. For the process to be selective one plastic must be rendered hydrophilic while another remains hydrophobic. In this study the potential for separation of PVC and PET has been investigated. Flame treatment was shown to be very effective in producing a hydrophilic surface on both plastics, although the process was not selective under the conditions investigated. Raising the temperature of the plastics above their softening point produced a hydrophobic recovery. As the softening point of PVC was significantly lower than for PET it was possible to produce a significant difference in hydrophobicity, as judged using contact angle measurement. When immersed in water the contact angle of the PVC was found to be strongly dependent on the pH. Good separation efficiency of the two plastics was achieved by froth flotation from pH 4 to 9. One particular advantage of the technique is that no chemical reagents may be required in the flotation stage. The practicalities of designing a flake treatment system however have to be addressed before considering it to be a viable industrial process.

  14. Flame treatment for the selective wetting and separation of PVC and PET

    International Nuclear Information System (INIS)

    Pascoe, R.D.; O'Connell, B.

    2003-01-01

    Flame treatment has been used for many years to modify the surface of plastics to allow coatings to be added. The effect of the treatment is to produce hydrophilic species on the surface of the plastic making it water-wettable. The production of hydrophilic plastic surfaces is also required in the selective separation of plastics by froth flotation. For the process to be selective one plastic must be rendered hydrophilic while another remains hydrophobic. In this study the potential for separation of PVC and PET has been investigated. Flame treatment was shown to be very effective in producing a hydrophilic surface on both plastics, although the process was not selective under the conditions investigated. Raising the temperature of the plastics above their softening point produced a hydrophobic recovery. As the softening point of PVC was significantly lower than for PET it was possible to produce a significant difference in hydrophobicity, as judged using contact angle measurement. When immersed in water the contact angle of the PVC was found to be strongly dependent on the pH. Good separation efficiency of the two plastics was achieved by froth flotation from pH 4 to 9. One particular advantage of the technique is that no chemical reagents may be required in the flotation stage. The practicalities of designing a flake treatment system however have to be addressed before considering it to be a viable industrial process

  15. Zirconia-based solid state chemical gas sensors

    CERN Document Server

    Zhuiykov, S

    2000-01-01

    This paper presents an overview of chemical gas sensors, based on solid state technology, that are sensitive to environmental gases, such as O sub 2 , SO sub x , NO sub x , CO sub 2 and hydrocarbons. The paper is focussed on performance of electrochemical gas sensors that are based on zirconia as a solid electrolyte. The paper considers sensor structures and selection of electrode materials. Impact of interfaces on sensor performance is discussed. This paper also provides a brief overview of electrochemical properties of zirconia and their effect on sensor performance. Impact of auxiliary materials on sensors performance characteristics, such as sensitivity, selectivity, response time and recovery time, is also discussed. Dual gas sensors that can be applied for simultaneous monitoring of the concentration of both oxygen and other gas phase components, are briefly considered

  16. Comparative study of three different kinds of geo membranes (PVC-P, HDPE, EPDM) used in the waterproofing of reservoirs; Estudio comparativo de tres geomembranas de distinta naturaleza (PVC-P, PEAD, EPDM) empleadas en la impermeabilizacion de balsas

    Energy Technology Data Exchange (ETDEWEB)

    Blanco Fernandez, M.; Castillo Rubi, F.; Soriano Carrillo, J.; Noval Arango, A. M.; Touze-Foltz, N.; Pargada Iglesias, L.; Rico Arnaiz, G.; Aguilar gonzalez, E.

    2014-02-01

    This work describes the long-term behaviour of three kinds of geo membranes which are constituted by plasticised poly vinyl chloride (PVC-P), high density polyethylene (HDPE) and terpolymer rubber of ethylene-propylene-dienic monomer (EPDM) used as the waterproofing system of the reservoirs Los Llanos de Mesa, San Isidro and El Golfo, respectively. Characteristics of the three original geo membranes and their behaviour along time are presented. Thicknesses, content and nature of the plasticizers ( in PVC-P), tensile properties dynamic and static puncture, fold ability at low temperature, shore hardness, tear resistance and carbon black ( in HDPE), joint strength (shear and peeling test) and microscopy, both optical and electronic scanning tests were carried out. Results obtained conclude with a long-term durability of geo membranes, independently of their macromolecular nature. These characteristics were determined by advanced analytical techniques in PVC-P samples, such as fourier Transform Infrared Spectroscopy (FTIR), Gas Chromatography (GC) and Mass Spectrometry (MS). Spectrometry (MS). (Author)

  17. Effect analysis of material properties of picosecond laser ablation for ABS/PVC

    Science.gov (United States)

    Tsai, Y. H.; Ho, C. Y.; Chiou, Y. J.

    2017-06-01

    This paper analytically investigates the picosecond laser ablation of ABS/PVC. Laser-pulsed ablation is a wellestablished tool for polymer. However the ablation mechanism of laser processing for polymer has not been thoroughly understood yet. This study utilized a thermal transport model to analyze the relationship between the ablation rate and laser fluences. This model considered the energy balance at the decomposition interface and Arrhenius law as the ablation mechanisms. The calculated variation of the ablation rate with the logarithm of the laser fluence agrees with the measured data. It is also validated in this work that the variation of the ablation rate with the logarithm of the laser fluence obeys Beer's law for low laser fluences. The effects of material properties and processing parameters on the ablation depth per pulse are also discussed for picosecond laser processing of ABS/PVC.

  18. Observability-Based Guidance and Sensor Placement

    Science.gov (United States)

    Hinson, Brian T.

    Control system performance is highly dependent on the quality of sensor information available. In a growing number of applications, however, the control task must be accomplished with limited sensing capabilities. This thesis addresses these types of problems from a control-theoretic point-of-view, leveraging system nonlinearities to improve sensing performance. Using measures of observability as an information quality metric, guidance trajectories and sensor distributions are designed to improve the quality of sensor information. An observability-based sensor placement algorithm is developed to compute optimal sensor configurations for a general nonlinear system. The algorithm utilizes a simulation of the nonlinear system as the source of input data, and convex optimization provides a scalable solution method. The sensor placement algorithm is applied to a study of gyroscopic sensing in insect wings. The sensor placement algorithm reveals information-rich areas on flexible insect wings, and a comparison to biological data suggests that insect wings are capable of acting as gyroscopic sensors. An observability-based guidance framework is developed for robotic navigation with limited inertial sensing. Guidance trajectories and algorithms are developed for range-only and bearing-only navigation that improve navigation accuracy. Simulations and experiments with an underwater vehicle demonstrate that the observability measure allows tuning of the navigation uncertainty.

  19. Degradation of PVC/HC blends. II. Terrestrial plant growth test.

    Science.gov (United States)

    Pascu, Mihaela; Agafiţei, Gabriela-Elena; Profire, Lenuţa; Vasile, Cornelia

    2009-01-01

    The behavior at degradation by soil burial of some plasticized polyvinyl chloride (PVC) based blends with a variable content of hydrolyzed collagen (HC) has been followed. The modifications induced in the environment by the polymer systems (pH variation, physiologic state of the plants, assimilatory pigments) were studied. Using the growth test of the terrestrial plants, we followed the development of Triticum (wheat), Helianthus annus minimus (little sunflower), Pisum sativum (pea), and Vicia X hybrida hort, during a vegetation cycle. After the harvest, for each plant, the quantities of chlorophyll and carotenoidic pigments and of trace- and macroelements were determined. It was proved that, in the presence of polymer blends, the plants do not suffer morphological and physiological modifications, the products released in the culture soil being not toxic for the plants growth.

  20. Effects of silica composition on gas permeability of ENR/PVC ...

    African Journals Online (AJOL)

    At higher SiO2 loadings, the mechanical strength of the membrane decreased due to the agglomeration of SiO2 particles. Gas permeation test was done on ENR/PVC/SiO2 membranes using NO2 gas and CO2 gas. The permeability of both gasses increased with the amount of SiO2 added to the membrane, which attributed ...

  1. Migration from PVC cling films compared with their field of application

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Lillemark, L.; Lund, L.

    1997-01-01

    Samples of PVC cling films were taken at importers, wholesalers and retail shops, and their overall migration to the alternative food simulant iso-octane was measured, after establishment of a correlation between overall migration to olive oil at 40 degrees C in 10 days and to iso-octane in 2 h...

  2. Adaptive Sensing Based on Profiles for Sensor Systems

    Directory of Open Access Journals (Sweden)

    Yoshiteru Ishida

    2009-10-01

    Full Text Available This paper proposes a profile-based sensing framework for adaptive sensor systems based on models that relate possibly heterogeneous sensor data and profiles generated by the models to detect events. With these concepts, three phases for building the sensor systems are extracted from two examples: a combustion control sensor system for an automobile engine, and a sensor system for home security. The three phases are: modeling, profiling, and managing trade-offs. Designing and building a sensor system involves mapping the signals to a model to achieve a given mission.

  3. Mechanical properties of oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend

    International Nuclear Information System (INIS)

    Gunasunderi Raju Nor Azowa Ibrahim; Mohammad Zaki Abd Rahman; Wan Md Zin Wan Yunus; Chantara Thevy Ratnam

    2004-01-01

    The effect of OPEFB fiber on the mechanical properties of the 50/50 PVC/ENR was investigated over a range of fiber loadings (0 to 30%). The OPEFB fiber reinforced PVC/ENR blend was prepared by using Haake Rheomixer at 150 degree C mixing temperature, 20 minutes total mixing time and 50 rpm rotor speed. The changes in tensile strength (Ts), Young's modulus, elongation break (Eb), flexural modulus, hardness and impact strength with the OPEFB fiber loadings were investigated. The results revealed that the flexural modulus, Young's modulus and hardness increased with the fiber loading. However, the impact strength, Ts and Eb found to decrease with the increase in fiber loading. (Author)

  4. Mycelial fungi completely remediate di(2-ethylhexyl)phthalate, the hazardous plasticizer in PVC blood storage bag

    Energy Technology Data Exchange (ETDEWEB)

    Pradeep, S. [Enzyme Technology Laboratory, Biotechnology Division, Department of Botany, University of Calicut, Kerala 673 635 (India); Benjamin, Sailas, E-mail: sailasben@yahoo.co.in [Enzyme Technology Laboratory, Biotechnology Division, Department of Botany, University of Calicut, Kerala 673 635 (India)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Three novel phthalate utilizing fungi: A. parasiticus, F. subglutinans and P. funiculosum. Black-Right-Pointing-Pointer Fungi utilize DEHP in PVC plastics in situ, in simple mineral salt medium. Black-Right-Pointing-Pointer Employing these fungi, a batch process can remediate phthalates in plastics. Black-Right-Pointing-Pointer Phthalate-free PVC can be recycled afresh. Black-Right-Pointing-Pointer Mineral salt and phthalate remediated into fungal biomass. - Abstract: This pioneering work describes how simply, inexpensively and efficiently novel fungi utilize the alarming plasticizer, di(2-ethylhexyl)phthalate (DEHP) blended in PVC blood storage bags (BB). In order to quantify total DEHP (33.5%, w/w) present in BB, it was extracted using n-hexane and confirmed by GC-MS. Three mycelial fungi, viz., Aspergillus parasiticus, Fusarium subglutinans and Penicillium funiculosum isolated in our laboratory form heavily plastics-contaminated soil - either singly or in consortium - completely consumed intact DEHP physically bound to BB by static submerged growth (28 Degree-Sign C) in simple basal salt medium (BSM). A two-stage cultivation strategy was adopted for the complete removal of DEHP from BB in situ. During the first growth stage, almost 70% DEHP contained in the BB was consumed in 2 weeks, accompanied by increased fungal biomass ({approx}0.15-0.35 g/g BB; OD {approx}7 at 600 nm) and a sharp declining (3.3) of initial pH (7.2). Spent BSM was replaced at this stagnant growth state (low pH), thus in the second stage, remaining DEHP bound to BB utilized completely (over 99%). Furthermore, A. parasiticus and F. subglutinans also grew well on scrapes of PVC water pipes in BSM. F. subglutinans was as efficient independently as consortium in completely utilizing the DEHP bound to BB, and these fungi offer great potentials for the inexpensive and eco-friendly bioremediation of phthalates in medical and allied PVC wastes on a large

  5. Mycelial fungi completely remediate di(2-ethylhexyl)phthalate, the hazardous plasticizer in PVC blood storage bag

    International Nuclear Information System (INIS)

    Pradeep, S.; Benjamin, Sailas

    2012-01-01

    Highlights: ► Three novel phthalate utilizing fungi: A. parasiticus, F. subglutinans and P. funiculosum. ► Fungi utilize DEHP in PVC plastics in situ, in simple mineral salt medium. ► Employing these fungi, a batch process can remediate phthalates in plastics. ► Phthalate-free PVC can be recycled afresh. ► Mineral salt and phthalate remediated into fungal biomass. - Abstract: This pioneering work describes how simply, inexpensively and efficiently novel fungi utilize the alarming plasticizer, di(2-ethylhexyl)phthalate (DEHP) blended in PVC blood storage bags (BB). In order to quantify total DEHP (33.5%, w/w) present in BB, it was extracted using n-hexane and confirmed by GC–MS. Three mycelial fungi, viz., Aspergillus parasiticus, Fusarium subglutinans and Penicillium funiculosum isolated in our laboratory form heavily plastics-contaminated soil – either singly or in consortium – completely consumed intact DEHP physically bound to BB by static submerged growth (28 °C) in simple basal salt medium (BSM). A two-stage cultivation strategy was adopted for the complete removal of DEHP from BB in situ. During the first growth stage, almost 70% DEHP contained in the BB was consumed in 2 weeks, accompanied by increased fungal biomass (∼0.15–0.35 g/g BB; OD ∼7 at 600 nm) and a sharp declining (3.3) of initial pH (7.2). Spent BSM was replaced at this stagnant growth state (low pH), thus in the second stage, remaining DEHP bound to BB utilized completely (over 99%). Furthermore, A. parasiticus and F. subglutinans also grew well on scrapes of PVC water pipes in BSM. F. subglutinans was as efficient independently as consortium in completely utilizing the DEHP bound to BB, and these fungi offer great potentials for the inexpensive and eco-friendly bioremediation of phthalates in medical and allied PVC wastes on a large scale through a batch process in alleviating the plactics waste management issue.

  6. Oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend-electron beam irradiation

    International Nuclear Information System (INIS)

    Ratnam, Chantara Thevy; Raju, Gunasunderi; Wan Md Zin Wan Yunus

    2007-01-01

    The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeV electron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies revealed that grafting of the OPEFB fiber with methyl acrylate did not cause appreciable effect to the tensile properties and gel fraction of the composites upon irradiation. The morphology of fractured surfaces of the composites, examined by a scanning electron microscope showed an improvement in the adhesion between the fiber and the matrix was achieved upon grafting of the fiber with methyl acrylate

  7. Tubo de PVC liso com diferentes envoltórios como material alternativo na drenagem subterrânea Smooth PVC tube with different envelopes as an alternative material in the subsurface drainage

    Directory of Open Access Journals (Sweden)

    Florício P. de Almeida

    2003-04-01

    Full Text Available Em regiões áridas e semi-áridas irrigadas a drenagem é, freqüentemente, necessária para prevenir o encharcamento do solo e o controle da salinidade. Um dos principais obstáculos na instalação de um sistema de drenagem subterrânea é o alto custo do investimento inicial. Assim, alguma contribuição que reduza o custo da instalação dos drenos e também do material usado, é altamente vantajosa. Diante disso, o objetivo desta pesquisa foi avaliar, em condições de laboratório, o desempenho hidráulico do sistema drenante constituído pelo tubo de PVC liso, próprio para esgoto doméstico, de 50,0 mm de diâmetro nominal e área aberta de 23,0 cm² m-1, e por três tipos de envoltório. O desempenho do tubo drenante de PVC liso demonstrou que esse material é tecnicamente viável para drenagem agrícola, principalmente com o uso de brita como envoltório.In irrigated arid and semi-arid regions the drainage is, frequently, necessary to prevent the waterlogging of the soil and to control the salinity. One of the main obstacles in the installation of a subsurface drainage system is the high cost of the initial investment. Thus, some contribution that reduces the cost of the installation of the drains and also of the material used is highly advantageous. The objective of this research was to evaluate, under laboratory conditions, the hydraulic performance of the drainage system constituted by smooth PVC tube used for sewer with 50.0 mm of nominal diameter and open area of 23.0 cm² m-1 and different types of envelopes, as an alternative material for subsurface drainage. The performance of the smooth PVC tube demonstrated that this material is technically viable for agricultural drainage principally when used with single stones as envelope.

  8. Resource Discovery in Activity-Based Sensor Networks

    DEFF Research Database (Denmark)

    Bucur, Doina; Bardram, Jakob

    This paper proposes a service discovery protocol for sensor networks that is specifically tailored for use in humancentered pervasive environments. It uses the high-level concept of computational activities (as logical bundles of data and resources) to give sensors in Activity-Based Sensor Networks...... (ABSNs) knowledge about their usage even at the network layer. ABSN redesigns classical network-level service discovery protocols to include and use this logical structuring of the network for a more practically applicable service discovery scheme. Noting that in practical settings activity-based sensor...

  9. 100 nm scale low-noise sensors based on aligned carbon nanotube networks: overcoming the fundamental limitation of network-based sensors

    Science.gov (United States)

    Lee, Minbaek; Lee, Joohyung; Kim, Tae Hyun; Lee, Hyungwoo; Lee, Byung Yang; Park, June; Jhon, Young Min; Seong, Maeng-Je; Hong, Seunghun

    2010-02-01

    Nanoscale sensors based on single-walled carbon nanotube (SWNT) networks have been considered impractical due to several fundamental limitations such as a poor sensitivity and small signal-to-noise ratio. Herein, we present a strategy to overcome these fundamental problems and build highly-sensitive low-noise nanoscale sensors simply by controlling the structure of the SWNT networks. In this strategy, we prepared nanoscale width channels based on aligned SWNT networks using a directed assembly strategy. Significantly, the aligned network-based sensors with narrower channels exhibited even better signal-to-noise ratio than those with wider channels, which is opposite to conventional random network-based sensors. As a proof of concept, we demonstrated 100 nm scale low-noise sensors to detect mercury ions with the detection limit of ~1 pM, which is superior to any state-of-the-art portable detection system and is below the allowable limit of mercury ions in drinking water set by most government environmental protection agencies. This is the first demonstration of 100 nm scale low-noise sensors based on SWNT networks. Considering the increased interests in high-density sensor arrays for healthcare and environmental protection, our strategy should have a significant impact on various industrial applications.

  10. 100 nm scale low-noise sensors based on aligned carbon nanotube networks: overcoming the fundamental limitation of network-based sensors

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Minbaek; Lee, Joohyung; Kim, Tae Hyun; Lee, Hyungwoo; Lee, Byung Yang; Hong, Seunghun [Department of Physics and Astronomy, Seoul National University, Shilim-Dong, Kwanak-Gu, Seoul 151-742 (Korea, Republic of); Park, June; Seong, Maeng-Je [Department of Physics, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul 156-756 (Korea, Republic of); Jhon, Young Min, E-mail: mseong@cau.ac.kr, E-mail: shong@phya.snu.ac.kr [Korea Institute of Science and Technology, Hawolgok-Dong, Seongbuk-Gu, Seoul 136-791 (Korea, Republic of)

    2010-02-05

    Nanoscale sensors based on single-walled carbon nanotube (SWNT) networks have been considered impractical due to several fundamental limitations such as a poor sensitivity and small signal-to-noise ratio. Herein, we present a strategy to overcome these fundamental problems and build highly-sensitive low-noise nanoscale sensors simply by controlling the structure of the SWNT networks. In this strategy, we prepared nanoscale width channels based on aligned SWNT networks using a directed assembly strategy. Significantly, the aligned network-based sensors with narrower channels exhibited even better signal-to-noise ratio than those with wider channels, which is opposite to conventional random network-based sensors. As a proof of concept, we demonstrated 100 nm scale low-noise sensors to detect mercury ions with the detection limit of {approx}1 pM, which is superior to any state-of-the-art portable detection system and is below the allowable limit of mercury ions in drinking water set by most government environmental protection agencies. This is the first demonstration of 100 nm scale low-noise sensors based on SWNT networks. Considering the increased interests in high-density sensor arrays for healthcare and environmental protection, our strategy should have a significant impact on various industrial applications.

  11. 100 nm scale low-noise sensors based on aligned carbon nanotube networks: overcoming the fundamental limitation of network-based sensors

    International Nuclear Information System (INIS)

    Lee, Minbaek; Lee, Joohyung; Kim, Tae Hyun; Lee, Hyungwoo; Lee, Byung Yang; Hong, Seunghun; Park, June; Seong, Maeng-Je; Jhon, Young Min

    2010-01-01

    Nanoscale sensors based on single-walled carbon nanotube (SWNT) networks have been considered impractical due to several fundamental limitations such as a poor sensitivity and small signal-to-noise ratio. Herein, we present a strategy to overcome these fundamental problems and build highly-sensitive low-noise nanoscale sensors simply by controlling the structure of the SWNT networks. In this strategy, we prepared nanoscale width channels based on aligned SWNT networks using a directed assembly strategy. Significantly, the aligned network-based sensors with narrower channels exhibited even better signal-to-noise ratio than those with wider channels, which is opposite to conventional random network-based sensors. As a proof of concept, we demonstrated 100 nm scale low-noise sensors to detect mercury ions with the detection limit of ∼1 pM, which is superior to any state-of-the-art portable detection system and is below the allowable limit of mercury ions in drinking water set by most government environmental protection agencies. This is the first demonstration of 100 nm scale low-noise sensors based on SWNT networks. Considering the increased interests in high-density sensor arrays for healthcare and environmental protection, our strategy should have a significant impact on various industrial applications.

  12. modern techniques and new sensors for determination of some metal ions

    International Nuclear Information System (INIS)

    Aglan, R.F.E.S.

    2004-01-01

    this work has been carried out to prepare some new sensors that can be used i the radioactive media. A novel homogenous solid state sensor responding to potassium ion was developed. i revealed good linear response with slope 44 ± 0.5 mV/decade over he concentration range 10 -4 -1.0 mol 1 -1 potassium ion with long life, high thermal and radiation stability. the influence of plasticizer, ionophore and conducting substrate on the analytical characterization of uranyl ion selective electrode was investigated. A new cesium sensor incorporating Cs-12- molybdophosphate as a sensing materials and DOP as solvent mediator in PVC matrix was constructed and used in the determination of cesium ion in the rage of 10 -5 10 -1 mol 1 -1 with a stop of 46±1.0 mV/decade in Ph range of 4-6

  13. Deterioration of plasticized PVC components in Apollo spacesuits

    DEFF Research Database (Denmark)

    Shashoua, Yvonne; Schnell, Ulrich; Young, Lisa

    2002-01-01

    Spacesuits from the Apollo era are unique in their history, materials and construction. This project involved the first detailed examination of the condition of the spacesuits since their acquisition by the National Air and Space Museum in the 1970s. Plasticized polyvinyl chloride (PVC) tubing...... in the Life Support System, used to transport air and water to the astronaut, and in the Liquid Cooling Garment, used to cool the wearer of the spacesuit, exhibited high levels of deterioration. Tubing was unacceptably discoloured, tacky to the touch and surfaces were obscured by crystals. Visual examination...

  14. Design and construction of new potentiometric sensors for determination of Al3+ ion based on (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine.

    Science.gov (United States)

    Mizani, F; Salmanzadeh Ardabili, S; Ganjaliab, M R; Faridbod, F; Payehghadr, M; Azmoodeh, M

    2015-04-01

    (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine (L) was used as an active component of PVC membrane electrode (PME), coated graphite electrode (CGE) and coated silver wire electrode (CWE) for sensing Al(3+) ion. The electrodes exhibited linear Nernstian responses to Al(3+) ion in the concentration range of 1.0×10(-6) to 1.0×10(-1)M (for PME, LOD=8.8×10(-7)M), 5.5×10(-7) to 2.0×10(-1)M (for CWE, LOD=3.3×10(-7)M) and 1.5×10(-7) to 1.0×10(-1)M (for CGE, LOD=9.2×10(-8)M). The best performances were observed with the membranes having the composition of L:PVC:NPOE:NaTPB in the ratio of 5:35:57:3 (w/w; mg). The electrodes have a response time of 6s and an applicable pH range of 3.5-9.1. The sensors have a lifetime of about 15weeks and exhibited excellent selectivity over a number of mono-, bi-, and tri-valent cations including alkali, alkaline earth metal, heavy and transition metal ions. Analytical utility of the proposed sensor has been further tested by using it as an indicator electrode in the potentiometric titration of Al(3+) with EDTA. The electrode was also successfully applied for the determination of Al(3+) ion in real and pharmaceutical samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. MEASUREMENT AND MODELLING OF SORPTION EQUILIBRIUM CURVE OF WATER ON PA6, PP, HDPE AND PVC BY USING FLORY-HUGGINS MODEL

    Directory of Open Access Journals (Sweden)

    Suherman Suherman

    2012-02-01

    Full Text Available The sorption of water on granular polyamide-6 (PA6, granular polypropylene (PP, and powdery high density polyethylene (HDPE and powdery polyvinyl chloride (PVC were measured using a gravimetric method in a magnetic suspension balance (MSB. The Flory-Huggins model was successfully applied on the sorption equilibrium curve of all investigated polymers. The influence of temperature is low. The value of Flory-Huggins parameters(c of PA6, PVC, PP and HDPE were 1.8, 5.8, 6.3, and 8.1, respectively. The water in PA6 is mainly bound moisture, while in PP, HDPE and PVC it is mainly surface moisture.

  16. Optical Fiber Sensors Based on Nanoparticle-Embedded Coatings

    Directory of Open Access Journals (Sweden)

    Aitor Urrutia

    2015-01-01

    Full Text Available The use of nanoparticles (NPs in scientific applications has attracted the attention of many researchers in the last few years. The use of NPs can help researchers to tune the physical characteristics of the sensing coating (thickness, roughness, specific area, refractive index, etc. leading to enhanced sensors with response time or sensitivity better than traditional sensing coatings. Additionally, NPs also offer other special properties that depend on their nanometric size, and this is also a source of new sensing applications. This review focuses on the current status of research in the use of NPs within coatings in optical fiber sensing. Most used sensing principles in fiber optics are briefly described and classified into several groups: absorbance-based sensors, interferometric sensors, fluorescence-based sensors, fiber grating sensors, and resonance-based sensors, among others. For each sensor group, specific examples of the utilization of NP-embedded coatings in their sensing structure are reported.

  17. A Novel Potentiometric Sensor Based on 1,2-Bis(N’-benzoylthioureido)benzene and Reduced Graphene Oxide for Determination of Lead (II) Cation in Raw Milk

    International Nuclear Information System (INIS)

    Abraham, Abigail Asha; Rezayi, Majid; Manan, Ninie S.A.; Narimani, Leila; Rosli, Ahmad Nazmi Bin; Alias, Yatimah

    2015-01-01

    We have developed a highly sensitive and selective potentiometric PVC-membrane sensor for lead (II) cation. A glassy carbon electrode (GCE) was modified with synthesized 1,2-Bis(N’-benzoylthioureido) benzene (BBTB) as an ionophore and reduced graphene oxide (RGO), and this material was characterized by scanning electron microscopy. The sensor shows sensitive and highly selective response to Pb(II) ion with a linear range from 6.31 × 10 −8 to 3.98 × 10 −2 M, Nernstian slope of 30.37 ± 0.62 mV per decade and a detection limit of 2.51 × 10 −8 M. The proposed sensor could be used in a pH range of 4.0–8.0. Selectivity coefficients were determined for known common cations by applying the match potential method (MPM). The sensor was successfully applied to monitor Pb(II) in raw milk and in potentiometric titration of Pb 2+ ions. The structure of BBTB ligand and its complexation with some common cations were investigated by using quantum mechanical DFT calculations. Lead (II) cation showed prominent affinity to the BBTB carrier

  18. Pyridine Vapors Detection by an Optical Fibre Sensor

    Directory of Open Access Journals (Sweden)

    Alberto Fernandez-Gutiérrez

    2008-02-01

    Full Text Available An optical fibre sensor has been implemented towards pyridine vapors detection;to achieve this, a novel vapochromic material has been used, which, in solid state, suffers achange in colour from blue to pink-white in presence of pyridine vapours. This complex isadded to a solution of PVC (Poly Vinyl Chloride, TBP (Tributylphosphate andtetrahydrofuran (THF, forming a plasticized matrix; by dip coating technique, the sensingmaterial is fixed onto a cleaved ended optical fibre. The fabrication process was optimizedin terms of number of dips and dipping speed, evaluating the final devices by dynamicrange. Employing a reflection set up, the absorbance spectra and changes in the reflectedoptical power of the sensors were registered to determine their response. A linear relationbetween optical power versus vapor concentration was obtained, with a detection limit of 1ppm (v/v.

  19. Patient Posture Monitoring System Based on Flexible Sensors

    Directory of Open Access Journals (Sweden)

    Youngsu Cha

    2017-03-01

    Full Text Available Monitoring patients using vision cameras can cause privacy intrusion problems. In this paper, we propose a patient position monitoring system based on a patient cloth with unobtrusive sensors. We use flexible sensors based on polyvinylidene fluoride, which is a flexible piezoelectric material. Theflexiblesensorsareinsertedintopartsclosetothekneeandhipoftheloosepatientcloth. We measure electrical signals from the sensors caused by the piezoelectric effect when the knee and hip in the cloth are bent. The measured sensor outputs are transferred to a computer via Bluetooth. We use a custom-made program to detect the position of the patient through a rule-based algorithm and the sensor outputs. The detectable postures are based on six human motions in and around a bed. The proposed system can detect the patient positions with a success rate over 88 percent for three patients.

  20. A Review of Microfiber-Based Temperature Sensors

    Directory of Open Access Journals (Sweden)

    Wanvisa Talataisong

    2018-02-01

    Full Text Available Optical microfiber-based temperature sensors have been proposed for many applications in a variety of industrial uses, including biomedical, geological, automotive, and defense applications. This increasing demand for these micrometric devices is attributed to their large dynamic range, high sensitivity, fast-response, compactness and robustness. Additionally, they can perform in-situ measurements remotely and in harsh environments. This paper presents an overview of optical microfibers, with a focus on their applications in temperature sensing. This review broadly divides microfiber-based temperature sensors into two categories: resonant and non-resonant microfiber sensors. While the former includes microfiber loop, knot and coil resonators, the latter comprises sensors based on functionally coated/doped microfibers, microfiber couplers, optical gratings and interferometers. In the conclusions, a summary of reported performances is presented.

  1. Treatment of PVC using an alternative low energy ion bombardment procedure

    Science.gov (United States)

    Rangel, Elidiane C.; dos Santos, Nazir M.; Bortoleto, José Roberto R.; Durrant, Steven F.; Schreiner, Wido H.; Honda, Roberto Y.; Rangel, Rita de Cássia C.; Cruz, Nilson C.

    2011-12-01

    In many applications, polymers have progressively substituted traditional materials such as ceramics, glasses, and metals. Nevertheless, the use of polymeric materials is still limited by their surface properties. Frequently, selective modifications are necessary to suit the surface to a given application. Amongst the most common treatments, plasma immersion ion implantation (PIII) has attracted the attention of many researchers owing to its versatility and practicality. This method, however, requires a power supply to provide high voltage (tens of kV) negative pulses, with a controlled duty cycle, width and frequency. Owing to this, the implementation of PIII on the industrial scale can become economically inviable. In this work, an alternative plasma treatment that enables low energy ion bombardment without the need of a high voltage pulse generator is presented. To evaluate the efficiency of the treatment of polymers, polyvinylchloride, PVC, specimens were exposed to 5 Pa argon plasmas for 3600 s, at excitation powers, P, of between 10 and 125 W. Through contact angle and atomic force microscopy data, the influence of P on the wettability, surface free energy and roughness of the samples was studied. Surface chemical composition was measured by X-ray photoelectron spectroscopy, XPS. To evaluate the effect of aging under atmospheric conditions, contact angle and XPS measurements were performed one and 1334 days after the treatment. The plasma potential and ion density around the driven electrode were determined from Langmuir probe measurements while the self-bias potential was derived with the aid of an oscilloscope. From these data it was possible to estimate the mean energy of ions bombarding the PVC surface. Chlorine, carbon and oxygen contamination were detected on the surface of the as-received PVC. Upon exposure to the plasma, the proportion of chlorine was observed to decrease while that of oxygen increased. Consequently, the wettability and surface energy

  2. Treatment of PVC using an alternative low energy ion bombardment procedure

    International Nuclear Information System (INIS)

    Rangel, Elidiane C.; Santos, Nazir M. dos; Bortoleto, José Roberto R.; Durrant, Steven F.; Schreiner, Wido H.; Honda, Roberto Y.; Cássia C Rangel, Rita de; Cruz, Nilson C.

    2011-01-01

    In many applications, polymers have progressively substituted traditional materials such as ceramics, glasses, and metals. Nevertheless, the use of polymeric materials is still limited by their surface properties. Frequently, selective modifications are necessary to suit the surface to a given application. Amongst the most common treatments, plasma immersion ion implantation (PIII) has attracted the attention of many researchers owing to its versatility and practicality. This method, however, requires a power supply to provide high voltage (tens of kV) negative pulses, with a controlled duty cycle, width and frequency. Owing to this, the implementation of PIII on the industrial scale can become economically inviable. In this work, an alternative plasma treatment that enables low energy ion bombardment without the need of a high voltage pulse generator is presented. To evaluate the efficiency of the treatment of polymers, polyvinylchloride, PVC, specimens were exposed to 5 Pa argon plasmas for 3600 s, at excitation powers, P, of between 10 and 125 W. Through contact angle and atomic force microscopy data, the influence of P on the wettability, surface free energy and roughness of the samples was studied. Surface chemical composition was measured by X-ray photoelectron spectroscopy, XPS. To evaluate the effect of aging under atmospheric conditions, contact angle and XPS measurements were performed one and 1334 days after the treatment. The plasma potential and ion density around the driven electrode were determined from Langmuir probe measurements while the self-bias potential was derived with the aid of an oscilloscope. From these data it was possible to estimate the mean energy of ions bombarding the PVC surface. Chlorine, carbon and oxygen contamination were detected on the surface of the as-received PVC. Upon exposure to the plasma, the proportion of chlorine was observed to decrease while that of oxygen increased. Consequently, the wettability and surface energy

  3. Polymerized Nile Blue derivatives for plasticizer-free fluorescent ion optode microsphere sensors.

    Science.gov (United States)

    Ngeontae, Wittaya; Xu, Chao; Ye, Nan; Wygladacz, Katarzyna; Aeungmaitrepirom, Wanlapa; Tuntulani, Thawatchai; Bakker, Eric

    2007-09-05

    Lipophilic H+-selective fluorophores such as Nile Blue derivatives are widely used in ISE-based pH sensors and bulk optodes, and are commonly dissolved in a plasticized matrix such as PVC. Unfortunately, leaching of the active sensing ingredients and plasticizer from the matrix dictates the lifetime of the sensors and hampers their applications in vivo, especially with miniaturized particle based sensors. We find that classical copolymerization of Nile Blue derivatives containing an acrylic side group gives rise to multiple reaction products with different spectral and H+-binding properties, making this approach unsuitable for the development of reliable sensor materials. This limitation was overcome by grafting Nile Blue to a self-plasticized poly(n-butyl acrylate) matrix via an urea or amide linkage between the Nile Blue base structure and the polymer. Optode leaching experiments into methanol confirmed the successful covalent attachment of the two chromoionophores to the polymer matrix. Both polymerized Nile Blue derivatives have satisfactory pH response and appropriate optical properties that are suitable for use in ion-selective electrodes and optodes. Plasticizer-free Na+-selective microsphere sensors using the polymerized chromoionophores were fabricated under mild conditions with an in-house sonic microparticle generator for the measurement of sodium activities at physiological pH. The measuring range for sodium was found as 10(-1)-10(-4) M and 1-10(-3) M, for Nile Blue derivatives linked via urea and amide functionalities, respectively, at physiological pH. The observed ion-exchange constants of the plasticizer-free microsphere were log K(exch) = -5.6 and log K(exch) = -6.5 for the same two systems, respectively. Compared with earlier Na+-selective bulk optodes, the fabricated optical sensing microbeads reported here have agreeable selectivity patterns, reasonably fast response times, and more appropriate measuring ranges for determination of Na+ activity

  4. APTAMER-BASED SERRS SENSOR FOR THROMBIN DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Cho, H; Baker, B R; Wachsmann-Hogiu, S; Pagba, C V; Laurence, T A; Lane, S M; Lee, L P; Tok, J B

    2008-07-02

    We describe an aptamer-based Surface Enhanced Resonance Raman Scattering (SERRS) sensor with high sensitivity, specificity, and stability for the detection of a coagulation protein, human a-thrombin. The sensor achieves high sensitivity and a limit of detection of 100 pM by monitoring the SERRS signal change upon the single step of thrombin binding to immobilized thrombin binding aptamer. The selectivity of the sensor is demonstrated by the specific discrimination of thrombin from other protein analytes. The specific recognition and binding of thrombin by the thrombin binding aptamer is essential to the mechanism of the aptamer-based sensor, as shown through measurements using negative control oligonucleotides. In addition, the sensor can detect 1 nM thrombin in the presence of complex biofluids, such as 10% fetal calf serum, demonstrating that the immobilized, 5{prime}-capped, 3{prime}-capped aptamer is sufficiently robust for clinical diagnostic applications. Furthermore, the proposed sensor may be implemented for multiplexed detection using different aptamer-Raman probe complexes.

  5. CALIBRAÇÃO DE SENSOR ELETRÔNICO DE UMIDADE EM DIFERENTES TEXTURAS DE SOLO / ELECTRONIC MOISTURE SENSOR CALIBRATION IN DIFFERENT SOIL TEXTURES

    Directory of Open Access Journals (Sweden)

    R. Gava

    2016-06-01

    Full Text Available A acurácia das leituras de sensores de umidade depende da qualidade do aparelho, mas também de sua calibração. Esses sensores eletrônicos já vêm de fábrica com calibração, porém, sabe-se que esta varia com o tipo de solo. O objetivo desse trabalho foi calibrar o sensor da Falker, modelo Hidrofarm, em solo de textura arenosa e argilosa. Foram utilizadas colunas de PVC de 0,1 m de diâmetro por 0,3 m de altura, que inseridas no solo após saturação, permitiram coletar amostras indeformadas, sem a desagregação das mesmas. No laboratório, cada coluna recebeu uma sonda do equipamento. Após as amostras serem saturadas, iniciou-se o processo de secagem natural, mantidas em laboratório com temperatura constante, e realizadas frequentes medidas de umidade. Sempre que se fazia leituras com o aparelho, as colunas eram também pesadas, para determinação da umidade com base massa. Assim, com a densidade do solo obtida pela relação entre a massa e o volume da coluna, foi possível encontrar a umidade volumétrica e correlacionar com as leituras do aparelho. Foram ajustadas curvas de correlação entre as leituras obtidas pelos sensores e as respetivas medidas de umidade. O desvio de leitura do sensor para a medida real de umidade apresentou-se ser sistemático, sendo de -8% para o solo de textura argilosa e de -4% para o solo de textura arenosa.

  6. The use of artificial neural networks for mathematical modeling of the effect of composition and production conditions on the properties of PVC floor coverings

    Directory of Open Access Journals (Sweden)

    Radovanović Rajko M.

    2017-01-01

    Full Text Available The application of PVC floor coverings is strongly connected with their end-use properties, which depend on the composition and processing conditions. It is very difficult to estimate the proper influence of the production parameters on the characteristics of PVC floor coverings due to their complex composition and various preparation procedures. The effect of different processing variables (such as time of bowling, temperature of bowling and composition of PVC plastisol on the mechanical properties of PVC floor coverings was investigated. The influence of different input parameters on the mechanical properties was successfully determined using an artificial neural network with an optimized number of hidden neurons. The Garson and Yoon models were applied to calculate and describe the variable contributions in the artificial neural networks. [Projekat Ministarstva nauke Republike Srbije, br. III 45022

  7. Polymer based amperometric hydrogen sensor

    International Nuclear Information System (INIS)

    Ramesh, C.; Periaswami, G.; Mathews, C.K.; Shankar, P.

    1993-01-01

    A polymer based amperometric hydrogen sensor has been developed for measuring hydrogen in argon. Polyvinyl alcohol-phosphoric acid serves as the solid electrolyte for proton conduction. The electrolyte is sandwiched between two palladium films. Short circuit current between the film at room temperature is measured and is found to be linearly dependant on hydrogen concentration in argon to which one side of the film is exposed. The other side is exposed to air. The response time of the sensor is found to be improved on application of a D.C. potential of 200 mV in series. The sensitivity of the sensor is in ppm range. This may be sufficient for monitoring cover gas hydrogen in FBTR. Work is underway to improve the long-term stability of the sensor. (author)

  8. Hydrogel-based sensor for CO2 measurements

    NARCIS (Netherlands)

    Herber, S.; Olthuis, Wouter; Bergveld, Piet; van den Berg, Albert

    2004-01-01

    A hydrogel-based sensor is presented for CO2 measurements. The sensor consists of a pressure sensor and porous silicon cover. A pH-sensitive hydrogel is confined between the two parts. Furthermore the porous cover contains a bicarbonate solution and a gaspermeable membrane. CO2 reacts with the

  9. Sensory aspects and water quality impacts of chlorinated and chloraminated drinking water in contact with HDPE and cPVC pipe.

    Science.gov (United States)

    Heim, Timothy H; Dietrich, Andrea M

    2007-02-01

    Pipes constructed with high-density polyethylene (HDPE) or chlorinated polyvinyl chloride (cPVC) are commonly used in drinking water distribution systems and premise plumbing. In this comprehensive investigation, the effects on odor, organic chemical release, trihalomethane (THM) formation, free chlorine demand and monochloramine demand were determined for water exposed to HDPE and cPVC pipes. The study was conducted in accordance with the Utility Quick Test (UQT), a migration/leaching protocol for analysis of materials in contact with drinking water. The sensory panel consistently attributed a weak to moderate intensity of a "waxy/plastic/citrus" odor to the water from the HDPE pipes but not the cPVC-contacted water samples. The odor intensity generated by the HDPE pipe remained relatively constant for multiple water flushes, and the odor descriptors were affected by disinfectant type. Water samples stored in both types of pipe showed a significant increase in the leaching of organic compounds when compared to glass controls, with HDPE producing 0.14 microgTOC/cm(2) pipe surface, which was significantly greater than the TOC release from cPVC. Water stored in both types of pipe showed disinfectant demands of 0.1-0.9 microg disinfectant/cm(2) pipe surface, with HDPE exerting more demand than cPVC. No THMs were detected in chlorinated water exposed to the pipes. The results demonstrate the impact that synthetic plumbing materials can have on sensory and chemical water quality, as well as the significant variations in drinking water quality generated from different materials.

  10. Reviewing Automated Sensor-Based Visitor Tracking Studies

    DEFF Research Database (Denmark)

    Mygind, Lærke; Bentsen, Peter

    2017-01-01

    The method of timing and tracking has a long history within visitor studies and exhibition evaluation. With an increase in indoor tracking research, sensor-based positioning tool usage in museums has grown, as have expectations regarding the efficacy of technological sensing systems. This literat......The method of timing and tracking has a long history within visitor studies and exhibition evaluation. With an increase in indoor tracking research, sensor-based positioning tool usage in museums has grown, as have expectations regarding the efficacy of technological sensing systems...... methods in terms of obtained level of detail, accuracy, level of obtrusiveness, automation of data entry, ability to time concurrent behaviors, and amount of observer training needed. Although individual sensor-based and traditional, observational methods had both strengths and weaknesses, all sensor......-based timing and tracking methods provided automated data entry and the opportunity to track a number of visitors simultaneously regardless of the available personnel....

  11. Determination of the Composition and Quantity of Phthalate Ester Additives in PVC Children's Toys. Greenpeace Research Laboratories Technical Note 06/97.

    Science.gov (United States)

    Stringer, Ruth; Labounskaia, Irina; Santillo, David; Johnston, Paul; Siddorn, John; Stephenson, Angela

    Polyvinyl chloride (vinyl or PVC) is widely used in toys and other children's products. This study, conducted by Greenpeace, examined the composition and quantity of phthalate ester additives in children's PVC toys, used to give the toys added flexibility. Drawn from 17 countries, a total of 71 toys designed to be chewed by babies and young…

  12. SYNTHESIS OF ACETIC ACID FROM ETHANOL BY ELECTROOXIDATION TECHNIQUE USING Ni-Cu-PVC ELECTRODE

    Directory of Open Access Journals (Sweden)

    Riyanto Riyanto

    2017-11-01

    Full Text Available A usage of Ni-Cu-PVC electrode for the oxidation of ethanol by electrochemical technique will be reported in this paper. In this work, the effect of electrodes on the yields of acetic acid was determined. Electrode used was made of the mixtures of Ni powder, Cu powder and of polyvinyl chloride (PVC with various percentages. Electrooxidation of 0.20 M ethanol in 0.16 M KOH  (24 mL were carried out using chrono coulometry (CC at a potential of 1050 mV for 6 hours with continious stirring. Electrooxdation result obtained was analyzed using High Performance Liquid Chromatography (HPLC. The test result shows that the composition of  Ni:Cu:PVC  at 75:20:5 have higher efficiency in the electrooxidation of ethanol to acetic acid.

  13. Comparative study of three different kinds of geomembranes (PVC-P, HDPE, EPDM) used in the waterproofing of reservoirs

    International Nuclear Information System (INIS)

    Blanco Fernandez, M.; Castillo Rubi, F.; Soriano Carrillo, J.; Noval Arango, A. M.; Touze-Foltz, N.; Pargada Iglesias, L.; Rico Arnaiz, G.; Aguilar gonzalez, E.

    2014-01-01

    This work describes the long-term behaviour of three kinds of geomembranes which are constituted by plasticized poly vinyl chloride (PVC-P), high density polyethylene (HDPE) and terpolymer rubber of ethylene-propylene-dienic monomer (EPDM) used as the waterproofing system of the reservoirs Los Llanos de Mesa, San Isidro and El Golfo, respectively. Characteristics of the three original geomembranes and their behaviour along time are presented. Thicknesses, content and nature of the plasticizers ( in PVC-P), tensile properties dynamic and static puncture, foldability at low temperature, shore hardeness, tear resistance and carbon black ( in HDPE), joint strength (shear and peeling test) and microscopy, both optical and electronic scanning tests were carried out. Results obtained conclude with a long-term durability of geomembranes, independently of their macromolecular nature. These characteristics were determined by advanced analytical techniques in PVC-P samples, such as fourier Transform Infrared Spectroscopy (FTIR), Gas Chromatography (GC) and Mass Spectrometry (MS). Spectrometry (MS). (Author)

  14. Avaliação de sensor capacitivo para o monitoramento do teor de água do solo Evaluation of a capacitance sensor for monitoring soil water content

    Directory of Open Access Journals (Sweden)

    Tadeu M. L. Cruz

    2010-02-01

    Full Text Available Este trabalho teve como objetivo avaliar sensores capacitivos desenvolvidos para monitorar o teor de água do solo. Os sensores foram submetidos a testes para avaliar o efeito da temperatura, o tempo de resposta, obter a equação de calibração e determinar a sua sensibilidade. Foram analisados em diferentes situações (solo, água e ar e temperaturas (25 ºC; 20 ºC; 15 ºC; 10 ºC; 5º C e 0 ºC. A calibração foi efetuada com um dos sensores capacitivos instalado em uma coluna de solo (indeformada contida em um tubo de PVC (0,015066 m³ e suspensa em um dos lados de uma balança de braços. Na outra extremidade da balança, havia uma célula de carga conectada a um sistema de aquisição de dados. Os resultados indicaram redução na frequência do sensor capacitivo com o aumento da temperatura. O sensor capacitivo apresentou alta velocidade de resposta (menos de um segundo ao imergi-lo na água e às variações da quantidade de água na amostra de solo e detectou as mudanças de perda de água pela coluna de solo no decorrer deste experimento, apresentando maior sensibilidade à medida que se diminui o conteúdo de água no solo. Portanto, o sensor capacitivo pode ser utilizado para determinar o teor de água do solo de forma adequada.This paper aims to evaluate a capacitance sensor for monitoring soil water content. Capacitance sensors were tested to evaluate the effect of temperature and response time, and to obtain the calibration equation and their sensitivity. Sensors were placed in different environments (soil, water and air and temperatures (25 ºC, 20 ºC, 15 ºC, 10 ºC, 5 ºC and 0 ºC. The calibration was performed with one of the capacitance sensors installed in a PVC column containing 0.015066 m³of undisturbed soil and hanged on one side of a scale with a load cell connected to a data acquisition board on the other side. Results showed reductions in the frequency response of the capacitance sensor with increasing

  15. An Umeclidinium membrane sensor; Two-step optimization strategy for improved responses.

    Science.gov (United States)

    Yehia, Ali M; Monir, Hany H

    2017-09-01

    In the scientific context of membrane sensors and improved experimentation, we devised an experimentally designed protocol for sensor optimization. Two-step strategy was implemented for Umeclidinium bromide (UMEC) analysis which is a novel quinuclidine-based muscarinic antagonist used for maintenance treatment of symptoms accompanied with chronic obstructive pulmonary disease. In the first place, membrane components were screened for ideal ion exchanger, ionophore and plasticizer using three categorical factors at three levels in Taguchi design. Secondly, experimentally designed optimization was followed in order to tune the sensor up for finest responses. Twelve experiments were randomly carried out in a continuous factor design. Nernstian response, detection limit and selectivity were assigned as responses in these designs. The optimized membrane sensor contained tetrakis-[3,5-bis(trifluoro- methyl)phenyl] borate (0.44wt%) and calix[6]arene (0.43wt%) in 50.00% PVC plasticized with 49.13wt% 2-ni-tro-phenyl octylether. This sensor, along with an optimum concentration of inner filling solution (2×10 -4 molL -1 UMEC) and 2h of soaking time, attained the design objectives. Nernstian response approached 59.7mV/decade and detection limit decreased by about two order of magnitude (8×10 -8 mol L -1 ) through this optimization protocol. The proposed sensor was validated for UMEC determination in its linear range (3.16×10 -7 -1×10 -3 mol L -1 ) and challenged for selective discrimination of other congeners and inorganic cations. Results of INCRUSE ELLIPTA ® inhalation powder analyses obtained from the proposed sensor and manufacturer's UPLC were statistically compared. Moreover the proposed sensor was successfully used for the determination of UMEC in plasma samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evaluation of dosimetric characteristics of graphene oxide/PVC nanocomposite for gamma radiation applications

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shahzad; Malekie, Shahryar; Ziaie, Farhood [Nuclear Science and Technology Research Institute (NSTRI), Karaj (Iran, Islamic Republic of). Radiation Application Research School; Rahighi, Reza; Tayyebi, Ahmad [Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Physics

    2017-04-01

    Graphene oxide-polyvinyl chloride composite was prepared using tetrahydrofuran solvent-assisted dispersion of characterized nano flakes of graphene oxide in polymer matrix. Electrical percolation threshold of GO/PVC nanocomposite was determined via a finite element simulation method with a 2D model and compared with experimental results. A conductive cell with two silver coated walls was designed and fabricated for exploring dosimetric properties of the composite. Some characteristics of the new nanocomposite such as linearity of dose response, repeatability, sensitivity and angular dependence are investigated. According to 2D proposed method, obtained data associated to electrical conductivity of the GO/polymer composite for PVC matrix plotted in different GO weight percentages and had good compatibility (validity) with experimental data. The dose response is linear in the 17-51 mGy dose range and it can be introduced for gamma radiation dosimetry in diagnostic activities.

  17. A carbon nanotube-based pressure sensor

    International Nuclear Information System (INIS)

    Karimov, Kh S; Saleem, M; Khan, Adam; Qasuria, T A; Mateen, A; Karieva, Z M

    2011-01-01

    In this study, a carbon nanotube (CNT)-based Al/CNT/Al pressure sensor was designed, fabricated and investigated. The sensor was fabricated by depositing CNTs on an adhesive elastic polymer tape and placing this in an elastic casing. The diameter of multiwalled nanotubes varied between 10 and 30 nm. The nominal thickness of the CNT layers in the sensors was in the range ∼300-430 μm. The inter-electrode distance (length) and the width of the surface-type sensors were in the ranges 4-6 and 3-4 mm, respectively. The dc resistance of the sensors decreased 3-4 times as the pressure was increased up to 17 kN m -2 . The resistance-pressure relationships were simulated.

  18. Inertial Sensor-Based Gait Recognition: A Review

    Science.gov (United States)

    Sprager, Sebastijan; Juric, Matjaz B.

    2015-01-01

    With the recent development of microelectromechanical systems (MEMS), inertial sensors have become widely used in the research of wearable gait analysis due to several factors, such as being easy-to-use and low-cost. Considering the fact that each individual has a unique way of walking, inertial sensors can be applied to the problem of gait recognition where assessed gait can be interpreted as a biometric trait. Thus, inertial sensor-based gait recognition has a great potential to play an important role in many security-related applications. Since inertial sensors are included in smart devices that are nowadays present at every step, inertial sensor-based gait recognition has become very attractive and emerging field of research that has provided many interesting discoveries recently. This paper provides a thorough and systematic review of current state-of-the-art in this field of research. Review procedure has revealed that the latest advanced inertial sensor-based gait recognition approaches are able to sufficiently recognise the users when relying on inertial data obtained during gait by single commercially available smart device in controlled circumstances, including fixed placement and small variations in gait. Furthermore, these approaches have also revealed considerable breakthrough by realistic use in uncontrolled circumstances, showing great potential for their further development and wide applicability. PMID:26340634

  19. Organic Thin-Film Transistor (OTFT-Based Sensors

    Directory of Open Access Journals (Sweden)

    Daniel Elkington

    2014-04-01

    Full Text Available Organic thin film transistors have been a popular research topic in recent decades and have found applications from flexible displays to disposable sensors. In this review, we present an overview of some notable articles reporting sensing applications for organic transistors with a focus on the most recent publications. In particular, we concentrate on three main types of organic transistor-based sensors: biosensors, pressure sensors and “e-nose”/vapour sensors.

  20. Chemical Sensors Based on Metal Oxide Nanostructures

    Science.gov (United States)

    Hunter, Gary W.; Xu, Jennifer C.; Evans, Laura J.; VanderWal, Randy L.; Berger, Gordon M.; Kulis, Mike J.; Liu, Chung-Chiun

    2006-01-01

    This paper is an overview of sensor development based on metal oxide nanostructures. While nanostructures such as nanorods show significan t potential as enabling materials for chemical sensors, a number of s ignificant technical challenges remain. The major issues addressed in this work revolve around the ability to make workable sensors. This paper discusses efforts to address three technical barriers related t o the application of nanostructures into sensor systems: 1) Improving contact of the nanostructured materials with electrodes in a microse nsor structure; 2) Controling nanostructure crystallinity to allow co ntrol of the detection mechanism; and 3) Widening the range of gases that can be detected by using different nanostructured materials. It is concluded that while this work demonstrates useful tools for furt her development, these are just the beginning steps towards realizati on of repeatable, controlled sensor systems using oxide based nanostr uctures.

  1. Wearable PPG sensor based alertness scoring system.

    Science.gov (United States)

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  2. Building SDN-Based Agricultural Vehicular Sensor Networks Based on Extended Open vSwitch.

    Science.gov (United States)

    Huang, Tao; Yan, Siyu; Yang, Fan; Pan, Tian; Liu, Jiang

    2016-01-19

    Software-defined vehicular sensor networks in agriculture, such as autonomous vehicle navigation based on wireless multi-sensor networks, can lead to more efficient precision agriculture. In SDN-based vehicle sensor networks, the data plane is simplified and becomes more efficient by introducing a centralized controller. However, in a wireless environment, the main controller node may leave the sensor network due to the dynamic topology change or the unstable wireless signal, leaving the rest of network devices without control, e.g., a sensor node as a switch may forward packets according to stale rules until the controller updates the flow table entries. To solve this problem, this paper proposes a novel SDN-based vehicular sensor networks architecture which can minimize the performance penalty of controller connection loss. We achieve this by designing a connection state detection and self-learning mechanism. We build prototypes based on extended Open vSwitch and Ryu. The experimental results show that the recovery time from controller connection loss is under 100 ms and it keeps rule updating in real time with a stable throughput. This architecture enhances the survivability and stability of SDN-based vehicular sensor networks in precision agriculture.

  3. Building SDN-Based Agricultural Vehicular Sensor Networks Based on Extended Open vSwitch

    Directory of Open Access Journals (Sweden)

    Tao Huang

    2016-01-01

    Full Text Available Software-defined vehicular sensor networks in agriculture, such as autonomous vehicle navigation based on wireless multi-sensor networks, can lead to more efficient precision agriculture. In SDN-based vehicle sensor networks, the data plane is simplified and becomes more efficient by introducing a centralized controller. However, in a wireless environment, the main controller node may leave the sensor network due to the dynamic topology change or the unstable wireless signal, leaving the rest of network devices without control, e.g., a sensor node as a switch may forward packets according to stale rules until the controller updates the flow table entries. To solve this problem, this paper proposes a novel SDN-based vehicular sensor networks architecture which can minimize the performance penalty of controller connection loss. We achieve this by designing a connection state detection and self-learning mechanism. We build prototypes based on extended Open vSwitch and Ryu. The experimental results show that the recovery time from controller connection loss is under 100 ms and it keeps rule updating in real time with a stable throughput. This architecture enhances the survivability and stability of SDN-based vehicular sensor networks in precision agriculture.

  4. Building SDN-Based Agricultural Vehicular Sensor Networks Based on Extended Open vSwitch

    Science.gov (United States)

    Huang, Tao; Yan, Siyu; Yang, Fan; Pan, Tian; Liu, Jiang

    2016-01-01

    Software-defined vehicular sensor networks in agriculture, such as autonomous vehicle navigation based on wireless multi-sensor networks, can lead to more efficient precision agriculture. In SDN-based vehicle sensor networks, the data plane is simplified and becomes more efficient by introducing a centralized controller. However, in a wireless environment, the main controller node may leave the sensor network due to the dynamic topology change or the unstable wireless signal, leaving the rest of network devices without control, e.g., a sensor node as a switch may forward packets according to stale rules until the controller updates the flow table entries. To solve this problem, this paper proposes a novel SDN-based vehicular sensor networks architecture which can minimize the performance penalty of controller connection loss. We achieve this by designing a connection state detection and self-learning mechanism. We build prototypes based on extended Open vSwitch and Ryu. The experimental results show that the recovery time from controller connection loss is under 100 ms and it keeps rule updating in real time with a stable throughput. This architecture enhances the survivability and stability of SDN-based vehicular sensor networks in precision agriculture. PMID:26797616

  5. Planar Laser-Based QEPAS Trace Gas Sensor

    Directory of Open Access Journals (Sweden)

    Yufei Ma

    2016-06-01

    Full Text Available A novel quartz enhanced photoacoustic spectroscopy (QEPAS trace gas detection scheme is reported in this paper. A cylindrical lens was employed for near-infrared laser focusing. The laser beam was shaped as a planar line laser between the gap of the quartz tuning fork (QTF prongs. Compared with a spherical lens-based QEPAS sensor, the cylindrical lens-based QEPAS sensor has the advantages of easier laser beam alignment and a reduction of stringent stability requirements. Therefore, the reported approach is useful in long-term and continuous sensor operation.

  6. Complicações determinadas por placas de cloreto de polivinila (PVC na estabilização da porção cervical caudal da coluna vertebral de cães Complications determined by polyvinylchloride (PVC plates in the stabilization of caudal cervical vertebral column of dogs

    Directory of Open Access Journals (Sweden)

    Mônica Vicky Bahr Arias

    2003-12-01

    Full Text Available Em 10 cães com peso médio de 14,6kg, as vértebras cervicais 5 e 6 foram cirurgicamente desestabilizadas através da secção do disco intervertebral e, em seguida, estabilizadas com placas ortopédicas confeccionadas com PVC de 2mm de espessura, para após 180 dias, proceder-se ao estudo histológico do tecido ósseo e conjuntivo circunvizinho. Constatou-se que o PVC causou alterações ósseas que podem ter favorecido o afrouxamento dos parafusos e a falha do implante. O material induziu ainda à formação de granuloma de corpo estranho e a reações inflamatórias locais que podem ter causado degradação do material implantado. Assim, placas de PVC, apesar de proporcionarem estabilidade e alinhamento da coluna vertebral, não satisfazem a maioria das propriedades necessárias a um biomaterial, não sendo recomendadaa a sua utilização em ortopedia veterinária.In ten dogs with an average mean weight of 14,6 kg, the cervical vertebra 5 and 6 were destabilized and fixed with plates of 2mm of thickness. The purpose of this work was to verify the effect of orthopedic PVC plates on the internal stabilization of the caudal cervical spine of dogs by studying the occurrence of alterations in the bone tissue and fibrous tissue adjacent to the plate after 180 days of permanence of the material in the dogs' organism. PVC causes progressive bone alterations, which, in the long term, could promote the loosening of the screws and failure of the implant. It also induces the formation of foreign body granuloma and inflammatory reactions which could cause degradation of the implant. Thus, PVC plates do not satisfy the majority of properties required of a biomaterial, its use not being recommended in veterinary orthopedics.

  7. The Effect of Zn-Al-Hydrotalcites Composited with Calcium Stearate and β-Diketone on the Thermal Stability of PVC

    Directory of Open Access Journals (Sweden)

    Runjuan Wen

    2011-03-01

    Full Text Available A clean-route synthesis of Zn-Al-hydrotalcites (Zn-Al-LDHs using zinc oxide and sodium aluminate solution has been developed. The as-obtained materials were characterized by X-ray diffraction (XRD, Fourier transform infrared spectroscopy (FT-IR, and scanning electron microscopy (SEM. The effects of metal ions at different molar ratios on the performance of hydrotalcites were discussed. The results showed that the Zn-Al-hydrotalcites can be successfully synthesized at three different Zn/Al ratios of 3:1, 2:1 and 1:1. Thermal aging tests of polyvinyl chloride (PVC mixed with Zn-Al-LDHs, calcium stearate (CaSt2 and β-diketone were carried out in a thermal aging test box by observing the color change. The results showed that Zn-Al-LDHs can not only enhance the stability of PVC significantly due to the improved capacity of HCl-adsorption but also increase the initial stability and ensure good-initial coloring due to the presence of the Zn element. The effects of various amounts of Zn-Al-LDHs, CaSt2 and β-diketone on the thermal stability of PVC were discussed. The optimum composition was determined to be 0.1 g Zn-Al-LDHs, 0.15 g CaSt2 and 0.25 g β-diketone in 5 g PVC.

  8. Elastic-Plastic Behaviour of Ultrasonic Assisted Compression of Polyvinyl Chloride (PVC) Foam

    Science.gov (United States)

    Muhalim, N. A. D.; Hassan, M. Z.; Daud, Y.

    2018-04-01

    The present study aims to investigate the elastic-plastic behaviour of ultrasonic assisted compression of PVC closed-cell foam. A series of static and ultrasonic compression test of PVC closed-cell foam were conducted at a constant cross head speed of 30 mm/min on dry surface condition. For quasi-static test, specimen was compressed between two rigid platens using universal testing machine. In order to evaluate the specimen behavior under ultrasonic condition, specimen was placed between a specifically design double-slotted block horn and rigid platen. The horn was designed and fabricated prior to the test as a medium to transmit the ultrasonic vibration from the ultrasonic transducer to the working specimen. It was tuned to a frequency of 19.89 kHz in longitudinal mode and provided an average oscillation amplitude at 6 µm on the uppermost surface. Following, the characteristics of stress-strain curves for quasi-static and ultrasonic compression tests were analyzed. It was found that the compressive stress was significantly reduced at the onset of superimposed ultrasonic vibration during plastic deformation.

  9. Charge Transfer Resistance and Differential Capacity of the Plasticized PVC Membrane/Water Interface

    Czech Academy of Sciences Publication Activity Database

    Langmaier, Jan; Stejskalová, Květoslava; Samec, Zdeněk

    2002-01-01

    Roč. 521, 1/2 (2002), s. 81-86 ISSN 0022-0728 R&D Projects: GA AV ČR IAA4040902 Institutional research plan: CEZ:AV0Z4040901 Keywords : impedance * PVC plasticized membrane * ion transfer kinetics Subject RIV: CG - Electrochemistry Impact factor: 2.027, year: 2002

  10. A Review of Carbon Nanotubes-Based Gas Sensors

    Directory of Open Access Journals (Sweden)

    Yun Wang

    2009-01-01

    Full Text Available Gas sensors have attracted intensive research interest due to the demand of sensitive, fast response, and stable sensors for industry, environmental monitoring, biomedicine, and so forth. The development of nanotechnology has created huge potential to build highly sensitive, low cost, portable sensors with low power consumption. The extremely high surface-to-volume ratio and hollow structure of nanomaterials is ideal for the adsorption of gas molecules. Particularly, the advent of carbon nanotubes (CNTs has fuelled the inventions of gas sensors that exploit CNTs' unique geometry, morphology, and material properties. Upon exposure to certain gases, the changes in CNTs' properties can be detected by various methods. Therefore, CNTs-based gas sensors and their mechanisms have been widely studied recently. In this paper, a broad but yet in-depth survey of current CNTs-based gas sensing technology is presented. Both experimental works and theoretical simulations are reviewed. The design, fabrication, and the sensing mechanisms of the CNTs-based gas sensors are discussed. The challenges and perspectives of the research are also addressed in this review.

  11. Roles of ionic strength and biofilm roughness on adhesion kinetics of Escherichia coli onto groundwater biofilm grown on PVC surfaces

    Science.gov (United States)

    Janjaroen, Dao; Ling, Fangqiong; Monroy, Guillermo; Derlon, Nicolas; Mogenroth, Eberhard; Boppart, Stephen A.; Liu, Wen-Tso; Nguyen, Thanh H.

    2013-01-01

    Mechanisms of Escherichia coli attachment on biofilms grown on PVC coupons were investigated. Biofilms were grown in CDC reactors using groundwater as feed solution over a period up to 27 weeks. Biofilm physical structure was characterized at the micro- and meso-scales using Scanning Electron Microscopy (SEM) and Optical Coherence Tomography (OCT), respectively. Microbial community diversity was analyzed with Terminal Restricted Fragment Length Polymorphism (T-RFLP). Both physical structure and microbial community diversity of the biofilms were shown to be changing from 2 weeks to 14 weeks, and became relatively stable after 16 weeks. A parallel plate flow chamber coupled with an inverted fluorescent microscope was also used to monitor the attachment of fluorescent microspheres and E. coli on clean PVC surfaces and biofilms grown on PVC surfaces for different ages. Two mechanisms of E. coli attachment were identified. The adhesion rate coefficients (kd) of E. coli on nascent PVC surfaces and 2-week biofilms increased with ionic strength. However, after biofilms grew for 8 weeks, the adhesion was found to be independent of solution chemistry. Instead, a positive correlation between kd and biofilm roughness as determined by OCT was obtained, indicating that the physical structure of biofilms could play an important role in facilitating the adhesion of E. coli cells. PMID:23497979

  12. Application of electrostatic separation to the recycling of plastic wastes: separation of PVC, PET, and ABS.

    Science.gov (United States)

    Park, Chul-Hyun; Jeon, Ho-Seok; Yu, Hyo-Shin; Han, Oh-Hyung; Park, Jai-Koo

    2008-01-01

    Plastics are widely used in everyday life as a useful material, and thus their consumption is growing at a rate of about 5% per year in Korea. However, the constant generation of plastic wastes and their disposal generates environmental problems along with economic loss. In particular, mixed waste plastics are difficult to recycle because of their inferior characteristics. A laboratory-scale triboelectrostatic separator unit has been designed and assembled for this study. On the basis of the control of electrostatic charge, the separation of three kinds of mixed plastics, polyvinyl chloride (PVC), poly(ethylene terephthalate) (PET), and acrylonitrile-butadiene-styrene (ABS), in a range of similar gravities has been performed through a two-stage separation process. Polypropylene (PP) and high-impact polystyrene (HIPS) were found to be the most effective materials for a tribo-charger in the separation of PVC, PET, and ABS. The charge-to-mass ratio (nC/g) of plastics increased with increasing air velocity in the tribo charger. In the first stage, using the PP cyclone charger, the separation efficiency of particles considerably depended on the air velocity (10 m/s), the relative humidity ( 20 kV), and the splitter position (+2 cm from the center) in the triboelelctrostatic separator unit. At this time, a PVC grade of 99.40% and a recovery of 98.10% have successfully been achieved. In the second stage, using the HIPS cyclone charger, a PET grade of 97.80% and a recovery of 95.12% could be obtained under conditions of 10 m/s, over 25 kV, a central splitter position, and less than 40% relative humidity. In order to obtain 99.9% PVC grade and 99.3% PET grade, their recoveries should be sacrificed by 20.9% and 27%, respectively, with moving the splitter from the center to a (+)6 cm position.

  13. SU-8 Based Piezoresistive Mechanical Sensor

    DEFF Research Database (Denmark)

    Thaysen, Jacob; Yalcinkaya, Arda Deniz; Vestergaard, R.K.

    2002-01-01

    We present the first SU-8 based piezoresistive mechanical sensor. Conventionally, silicon has been used as a piezoresistive material due to its high gauge factor and thereby high sensitivity to strain changes in a sensor. By using the fact that SU-8 is much softer than silicon and that a gold...

  14. Software package to automate the design and production of translucent building structures made of pvc

    Directory of Open Access Journals (Sweden)

    Petrova Irina Yur’evna

    2016-08-01

    Full Text Available The article describes the features of the design and production of translucent building structures made of PVC. The analysis of the automation systems of this process currently existing on the market is carried out, their advantages and disadvantages are identified. Basing on this analysis, a set of requirements for automation systems for the design and production of translucent building structures made of PVC is formulated; the basic entities are involved in those business processes. The necessary functions for the main application and for dealers’ application are specified. The main application is based on technological platform 1C: Enterprise 8.2. The dealers’ module is .NET application and is developed with the use of Microsoft Visual Studio and Microsoft SQL Server because these software products have client versions free for end users (.NET Framework 4.0 Client Profile and Microsoft SQL Server 2008 Express. The features of the developed software complex implementation are described; the relevant charts are given. The scheme of system deployment and protocols of data exchange between 1C server, 1C client and dealer is presented. Also the functions supported by 1C module and .NET module are described. The article describes the content of class library developed for .NET module. The specification of integration of the two applications in a single software package is given. The features of the GUI organization are described; the corresponding screenshots are given. The possible ways of further development of the described software complex are presented and a conclusion about its competitiveness and expediency of new researches is made.

  15. Development of GaN-based microchemical sensor nodes

    Science.gov (United States)

    Prokopuk, Nicholas; Son, Kyung-Ah; George, Thomas; Moon, Jeong S.

    2005-01-01

    Sensors based III-N technology are gaining significant interest due to their potential for monolithic integration of RF transceivers and light sources and the capability of high temperature operations. We are developing a GaN-based micro chemical sensor node for remote detection of chemical toxins, and present electrical responses of AlGaN/GaN HEMT (High Electron Mobility Transistor) sensors to chemical toxins as well as other common gases.

  16. Safety and effectiveness evaluation of a domestic peritoneal dialysis fluid packed in non-PVC bags: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Zhou, Jianhui; Cao, Xueying; Lin, Hongli; Ni, Zhaohui; He, Yani; Chen, Menghua; Zheng, Hongguang; Chen, Xiangmei

    2015-12-29

    Peritoneal dialysis is an important type of renal replacement therapy for uremic patients. In peritoneal dialysis, fluids fill in and flow out of the abdominal cavity three to five times per day. Usually, the fluid is packed in a polyvinyl chloride (PVC) bag. Safety concerns have arisen over di-(2-ethylhexyl) phthalate, which is essential in the formation of PVC materials. In 2011, the National Development and Reform Commission of China released a catalog of industrial structural adjustments, mandating the elimination of PVC bags for intravenous infusion and food containers. Although bags for peritoneal dialysis fluid were not included in the elimination list, several manufacturers began to develop new materials for fluid bags. HUAREN peritoneal dialysis fluid consists of the same electrolytes and buffer agent as in Baxter fluid, but is packed in bags that do not contain PVC. This multicenter randomized controlled trial was designed to compare peritoneal dialysis fluid packed in non-PVC-containing and PVC-containing bags. Further, the study sought to determine the proper dose of peritoneal dialysis fluid and the actual survival rates of Chinese patients undergoing peritoneal dialysis. The study participants are adults undergoing continuous ambulatory peritoneal dialysis for 30 days to 6 months. All eligible patients are randomized (1:1) to peritoneal dialysis with Baxter and HUAREN dialysis fluids (initial dose, 6 l/day), with dosages adjusted according to a unified protocol. The primary outcomes are the 1-, 2-, 3-, 4-, and 5-year overall survival rates. Secondary outcome measures include technique survival rates, reductions in estimated glomerular filtration rate, nutritional status, quality of life, cardiovascular events, medical costs and drop-out rates. Safety outcome measures include adverse events, changes in vital signs and laboratory parameters, peritonitis, allergies, and quality of products. This study is the first to evaluate the long-term safety and

  17. Optical Fiber Sensors Based on Fiber Ring Laser Demodulation Technology.

    Science.gov (United States)

    Xie, Wen-Ge; Zhang, Ya-Nan; Wang, Peng-Zhao; Wang, Jian-Zhang

    2018-02-08

    A review for optical fiber sensors based on fiber ring laser (FRL) demodulation technology is presented. The review focuses on the principles, main structures, and the sensing performances of different kinds of optical fiber sensors based on FRLs. First of all, the theory background of the sensors has been discussed. Secondly, four different types of sensors are described and compared, which includes Mach-Zehnder interferometer (MZI) typed sensors, Fabry-Perot interferometer (FPI) typed sensors, Sagnac typed sensors, and fiber Bragg grating (FBG) typed sensors. Typical studies and main properties of each type of sensors are presented. Thirdly, a comparison of different types of sensors are made. Finally, the existing problems and future research directions are pointed out and analyzed.

  18. Mechanical, Spectroscopic and Micro-structural Characterization of Banana Particulate Reinforced PVC Composite as Piping Material

    Directory of Open Access Journals (Sweden)

    B. Dan-asabe

    2016-06-01

    Full Text Available A banana particulate reinforced polyvinyl chloride (PVC composite was developed with considerabley low cost materials having an overall light-weight and good mechanical properties for potential application as piping material. The specimen composite material was produced with the banana (stem particulate as reinforcement using compression molding. Results showed that density and elastic Modulus of the composite decreases and increases respectively with increasing weight fraction of the particulate reinforcement. The tensile strength increased to a maximum of 42 MPa and then decreased steadily. The composition with optimum mechanical property (42 MPa was determined at 8, 62 and 30 % formulation of banana stem particulates (reinforcement, PVC (matrix and Kankara clay (filler respectively with corresponding percentage water absorption of 0.79 %, Young’s Modulus of 1.3 GPa, flexural strength of 92 MPa and density of 1.24 g/cm3. Fourier Transform Infrared (FTIR analysis of the constituents showed identical bands within the range 4000–1000 cm-1 with renown research work. Scanning Electron Microscopy (SEM result showed fairly uniform distribution of constituents’ phases. X-Ray Fluorescence (XRF confirms the X-ray diffraction (XRD result of the presence of minerals of kaolinite, quartz, rutile and illite in the kaolin clay. Comparison with conventional piping materials showed the composite offered a price savings per meter length of 84 % and 25 % when compared with carbon steel and PVC material.

  19. Development of a Portable Taste Sensor with a Lipid/Polymer Membrane

    Directory of Open Access Journals (Sweden)

    Kiyoshi Toko

    2013-01-01

    Full Text Available We have developed a new portable taste sensor with a lipid/polymer membrane and conducted experiments to evaluate the sensor’s performance. The fabricated sensor consists of a taste sensor chip (40 mm × 26 mm × 2.2 mm with working and reference electrodes and a portable sensor device (80 mm × 25 mm × 20 mm. The working electrode consists of a taste-sensing site comprising a poly(hydroxyethylmethacrylate (pHEMA hydrogel layer with KCl as the electrolyte layer and a lipid/polymer membrane as the taste sensing element. The reference electrode comprises a polyvinyl chloride (PVC membrane layer with a small hole and a pHEMA layer with KCl. The whole device is the size of a USB memory stick, making it suitable for portable use. The sensor’s response to tannic acid as the standard astringency substance showed good accuracy and reproducibility, and was comparable with the performance of a commercially available taste sensing system. Thus, it is possible for this sensor to be used for in-field evaluations and it can make a significant contribution to the food industry, as well as in various fields of research.

  20. Chemical Sensors Based on Cyclodextrin Derivatives.

    Science.gov (United States)

    Ogoshi, Tomoki; Harada, Akira

    2008-08-25

    This review focuses on chemical sensors based on cyclodextrin (CD) derivatives. This has been a field of classical interest, and is now of current interest for numerous scientists. First, typical chemical sensors using chromophore appended CDs are mentioned. Various "turn-off" and "turn-on" fluorescent chemical sensors, in which fluorescence intensity was decreased or increased by complexation with guest molecules, respectively, were synthesized. Dye modified CDs and photoactive metal ion-ligand complex appended CDs, metallocyclodextrins, were also applied for chemical sensors. Furthermore, recent novel approaches to chemical sensing systems using supramolecular structures such as CD dimers, trimers and cooperative binding systems of CDs with the other macrocycle [2]rotaxane and supramolecular polymers consisting of CD units are mentioned. New chemical sensors using hybrids of CDs with p-conjugated polymers, peptides, DNA, nanocarbons and nanoparticles are also described in this review.

  1. Toward Sensor-Based Context Aware Systems

    Directory of Open Access Journals (Sweden)

    Kouhei Takada

    2012-01-01

    Full Text Available This paper proposes a methodology for sensor data interpretation that can combine sensor outputs with contexts represented as sets of annotated business rules. Sensor readings are interpreted to generate events labeled with the appropriate type and level of uncertainty. Then, the appropriate context is selected. Reconciliation of different uncertainty types is achieved by a simple technique that moves uncertainty from events to business rules by generating combs of standard Boolean predicates. Finally, context rules are evaluated together with the events to take a decision. The feasibility of our idea is demonstrated via a case study where a context-reasoning engine has been connected to simulated heartbeat sensors using prerecorded experimental data. We use sensor outputs to identify the proper context of operation of a system and trigger decision-making based on context information.

  2. Laser-based gas sensors keep moisture out of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2006-07-15

    Natural gas often contains contaminants that cause corrosion, and long-term deterioration, and must be cleaned and brought to pipeline standards before it can be delivered to high-pressure, long-distance pipelines. Many older sensors produce false data that can result in contaminated gas getting through. This article presented details of the SpectraSensor, a new laser-based sensor technology used by the El Paso Natural Gas Company (EPNG). The SpectraSensor is comprised of a tunable diode laser (TDL) based technology developed by the National American Space Agency (NASA). The gas analyzer provides non-contact measurement of moisture, carbon dioxide, and other corrosives in natural gas pipelines, and the tunable laser-based gas sensors are fast, accurate, and flexible. Producers can monitor El Paso's gas analyzer readings by capturing the electronic signal from El Paso's unit via a SCADA system and view the readings from control rooms. While initial purchase price is higher than more problematic surface-based gas sensors, an evaluation of the technology has indicated that maintenance savings alone may provide an almost immediate return on investments. Unlike electrochemical and crystal gas sensors, laser-based gas analyzers do not come into direct contact with any substances, a fact which practically eliminates maintenance and operational costs. Studies have shown that the cost of operating conventional electrochemical sensors can result in a cumulative annual expense exceeding $50,000 per unit including labour; recalibration and rebuilding; back-up sensor heads; and gas dehydration and tariffs. 1 fig.

  3. Electrochemical DNA Hybridization Sensors Based on Conducting Polymers

    Science.gov (United States)

    Rahman, Md. Mahbubur; Li, Xiao-Bo; Lopa, Nasrin Siraj; Ahn, Sang Jung; Lee, Jae-Joon

    2015-01-01

    Conducting polymers (CPs) are a group of polymeric materials that have attracted considerable attention because of their unique electronic, chemical, and biochemical properties. This is reflected in their use in a wide range of potential applications, including light-emitting diodes, anti-static coating, electrochromic materials, solar cells, chemical sensors, biosensors, and drug-release systems. Electrochemical DNA sensors based on CPs can be used in numerous areas related to human health. This review summarizes the recent progress made in the development and use of CP-based electrochemical DNA hybridization sensors. We discuss the distinct properties of CPs with respect to their use in the immobilization of probe DNA on electrode surfaces, and we describe the immobilization techniques used for developing DNA hybridization sensors together with the various transduction methods employed. In the concluding part of this review, we present some of the challenges faced in the use of CP-based DNA hybridization sensors, as well as a future perspective. PMID:25664436

  4. Electrochemical DNA Hybridization Sensors Based on Conducting Polymers

    Directory of Open Access Journals (Sweden)

    Md. Mahbubur Rahman

    2015-02-01

    Full Text Available Conducting polymers (CPs are a group of polymeric materials that have attracted considerable attention because of their unique electronic, chemical, and biochemical properties. This is reflected in their use in a wide range of potential applications, including light-emitting diodes, anti-static coating, electrochromic materials, solar cells, chemical sensors, biosensors, and drug-release systems. Electrochemical DNA sensors based on CPs can be used in numerous areas related to human health. This review summarizes the recent progress made in the development and use of CP-based electrochemical DNA hybridization sensors. We discuss the distinct properties of CPs with respect to their use in the immobilization of probe DNA on electrode surfaces, and we describe the immobilization techniques used for developing DNA hybridization sensors together with the various transduction methods employed. In the concluding part of this review, we present some of the challenges faced in the use of CP-based DNA hybridization sensors, as well as a future perspective.

  5. Graphene-Paper Based Electrochemical Sensors

    DEFF Research Database (Denmark)

    Zhang, Minwei; Halder, Arnab; Cao, Xianyi

    2017-01-01

    in electrochemical sensors and energy technologies amongothers. In this chapter, we present some examples to overview recent advances in theresearch and development of two-dimensional (2D) graphene papers as new materialsfor electrochemical sensors. The chapter covers the design, fabrication, functionalizationand...... functionalization ofgraphene papers with polymer and nanoscale functional building blocks for electrochemical-sensing purposes. In terms of electrochemical-sensing applications, the emphasis ison enzyme-graphene and nanoparticle-graphene paper-based systems for the detectionof glucose. We finally conclude...

  6. Dosimetry of the JS-6500 industrial irradiator for the irradiation of the PVC graduated flasks

    International Nuclear Information System (INIS)

    Castaneda F, A.; Carrasco A, H.; Martinez P, M.E.

    2002-01-01

    The dosimetry of the JS-6500 AECL irradiator was realized, outside of the industrial transportation rails to know the dose distribution, as well as its dose speed. This one with the intention of exposing to gamma radiation; plastified PVC graduated flasks and evaluating their interweavement or degradation or both. This study of dosimetry was carried out by means of a theoretical and experimental evaluation in air atmosphere. The results allow to know the irradiation conditions of the PVC graduated flasks as well as those results prove that has not a significant difference among the obtained result as theoretical as experimentally due to that the obtained result in the theoretical evaluation is 2.62 KGy/h and the result for the case of the experimental evaluation is 2.74 KGy/h. (Author)

  7. Biological and chemical sensors based on graphene materials.

    Science.gov (United States)

    Liu, Yuxin; Dong, Xiaochen; Chen, Peng

    2012-03-21

    Owing to their extraordinary electrical, chemical, optical, mechanical and structural properties, graphene and its derivatives have stimulated exploding interests in their sensor applications ever since the first isolation of free-standing graphene sheets in year 2004. This article critically and comprehensively reviews the emerging graphene-based electrochemical sensors, electronic sensors, optical sensors, and nanopore sensors for biological or chemical detection. We emphasize on the underlying detection (or signal transduction) mechanisms, the unique roles and advantages of the used graphene materials. Properties and preparations of different graphene materials, their functionalizations are also comparatively discussed in view of sensor development. Finally, the perspective and current challenges of graphene sensors are outlined (312 references).

  8. Experimental and numerical analysis of water hammer in a large-scale PVC pipeline apparatus

    NARCIS (Netherlands)

    Bergant, A.; Hou, Q.; Keramat, A.; Tijsseling, A.S.; Gajic, A.; Benisek, M.; Nedeljkovic, M.

    2011-01-01

    This paper investigates the effects of the pipe-wall viscoelasticity on water-hammer pressures. A large-scale pipeline apparatus made of polyvinyl chloride (PVC) at Deltares, Delft, The Netherlands, has been used to carry out waterhammer experiments. Tests have been conducted in a

  9. etermination of Nitrate, Potassium, and Calcium using Ion-Selective Sensors in Soilless Plant Growth Media of Some Vegetables

    Directory of Open Access Journals (Sweden)

    Melda ALTIKATOĞLU

    2017-02-01

    Full Text Available Since it is important to transfer the minerals desired by plants for a long time in a controlled manner, simple and economical new micro and macro scale agricultural production systems are needed. In this study, the nutrients in the plant nutrient solutionwere kept at the required level according to the needs of the plant, using computer controlled potentiometric micro-sized chemical sensor systems. Polyvinylchloride (PVC -based ion-selective sensors have been used to sensitively and selectively measure the concentration of macro nutrient NO3−, K+, and Ca2+ions in the hydroponic solution. It has been found that the nitrate, potassium and calcium ion levels required for the green pepper and eggplants grown in the greenhouse are different. The results showed that in the first two months of growth, the pepper consumed nitrate in a lesser amount than the eggplant. In addition, it was determined that the amount of potassium consumed by plants was higher than that of other nutrients.

  10. Characterization of cement-based materials using a reusable piezoelectric impedance-based sensor

    Science.gov (United States)

    Tawie, R.; Lee, H. K.

    2011-08-01

    This paper proposes a reusable sensor, which employs a piezoceramic (PZT) plate as an active sensing transducer, for non-destructive monitoring of cement-based materials based on the electromechanical impedance (EMI) sensing technique. The advantage of the sensor design is that the PZT can be easily removed from the set-up and re-used for repetitive tests. The applicability of the sensor was demonstrated for monitoring of the setting of cement mortar. EMI measurements were performed using an impedance analyzer and the transformation of the specimen from the plastic to solid state was monitored by automatically measuring the changes in the PZT conductance spectra with respect to curing time using the root mean square deviation (RMSD) algorithm. In another experiment, drying-induced moisture loss of a hardened mortar specimen at saturated surface dry (SSD) condition was measured, and monitored using the reusable sensor to establish a correlation between the RMSD values and moisture loss rate. The reusable sensor was also demonstrated for detecting progressive damages imparted on a mortar specimen attached with the sensor under several loading levels before allowing it to load to failure. Overall, the reusable sensor is an effective and efficient monitoring device that could possibly be used for field application in characterization of cement-based materials.

  11. Characterization of cement-based materials using a reusable piezoelectric impedance-based sensor

    International Nuclear Information System (INIS)

    Tawie, R; Lee, H K

    2011-01-01

    This paper proposes a reusable sensor, which employs a piezoceramic (PZT) plate as an active sensing transducer, for non-destructive monitoring of cement-based materials based on the electromechanical impedance (EMI) sensing technique. The advantage of the sensor design is that the PZT can be easily removed from the set-up and re-used for repetitive tests. The applicability of the sensor was demonstrated for monitoring of the setting of cement mortar. EMI measurements were performed using an impedance analyzer and the transformation of the specimen from the plastic to solid state was monitored by automatically measuring the changes in the PZT conductance spectra with respect to curing time using the root mean square deviation (RMSD) algorithm. In another experiment, drying-induced moisture loss of a hardened mortar specimen at saturated surface dry (SSD) condition was measured, and monitored using the reusable sensor to establish a correlation between the RMSD values and moisture loss rate. The reusable sensor was also demonstrated for detecting progressive damages imparted on a mortar specimen attached with the sensor under several loading levels before allowing it to load to failure. Overall, the reusable sensor is an effective and efficient monitoring device that could possibly be used for field application in characterization of cement-based materials

  12. Sensor-based material tagging system

    International Nuclear Information System (INIS)

    Vercellotti, L.C.; Cox, R.W.; Ravas, R.J.; Schlotterer, J.C.

    1991-01-01

    Electronic identification tags are being developed for tracking material and personnel. In applying electronic identification tags to radioactive materials safeguards, it is important to measure attributes of the material to ensure that the tag remains with the material. The addition of a microcontroller with an on-board analog-to-digital converter to an electronic identification tag application-specific integrated-circuit has been demonstrated as means to provide the tag with sensor data. Each tag is assembled into a housing, which serves as a scale for measuring the weight of a paint-can-sized container and its contents. Temperature rise of the can above ambient is also measured, and a piezoelectric detector detects disturbances and immediately puts the tag into its alarm and beacon mode. Radiation measurement was also considered, but the background from nearby containers was found to be excessive. The sensor-based tagging system allows tracking of the material in cans as it is stored in vaults or is moved through the manufacturing process. The paper presents details of the sensor-based material tagging system and describes a demonstration system

  13. Materials-Product chains. Theory and an application to zinc and PVC gutters

    Energy Technology Data Exchange (ETDEWEB)

    Kandelaars, P.; Van den Bergh, J. [Tinbergen Inst., Rotterdam (Netherlands)

    1995-12-31

    A framework is presented for the analysis of economic and environmental impacts of policies applied to materials-product (MP) chains. This is based on material flows, product flows, costs, prices and optimal management of an MP chain. The main difference with other studies focusing on materials flows is that in this study the link between products of services and materials is explicitly dealt with. The framework is developed on the basis of materials balance conditions, production functions allowing for substitution, and recycling of both materials and products. After presenting theoretical MP chain-models and analytical results, an application to the problem of choosing between zinc and PVC gutters is discussed. Here optimal MP chain management decisions are presented for various policy and strategy scenarios. 3 figs., 5 tabs., 12 refs., 3 appendices

  14. Optical hydrogen sensors based on metal-hydrides

    Science.gov (United States)

    Slaman, M.; Westerwaal, R.; Schreuders, H.; Dam, B.

    2012-06-01

    For many hydrogen related applications it is preferred to use optical hydrogen sensors above electrical systems. Optical sensors reduce the risk of ignition by spark formation and are less sensitive to electrical interference. Currently palladium and palladium alloys are used for most hydrogen sensors since they are well known for their hydrogen dissociation and absorption properties at relatively low temperatures. The disadvantages of palladium in sensors are the low optical response upon hydrogen loading, the cross sensitivity for oxygen and carbon, the limited detection range and the formation of micro-cracks after some hydrogen absorption/desorption cycles. In contrast to Pd, we find that the use of magnesium or rear earth bases metal-hydrides in optical hydrogen sensors allow tuning of the detection levels over a broad pressure range, while maintaining a high optical response. We demonstrate a stable detection layer for detecting hydrogen below 10% of the lower explosion limit in an oxygen rich environment. This detection layer is deposited at the bare end of a glass fiber as a micro-mirror and is covered with a thin layer of palladium. The palladium layer promotes the hydrogen uptake at room temperature and acts as a hydrogen selective membrane. To protect the sensor for a long time in air a final layer of a hydrophobic fluorine based coating is applied. Such a sensor can be used for example as safety detector in automotive applications. We find that this type of fiber optic hydrogen sensor is also suitable for hydrogen detection in liquids. As example we demonstrate a sensor for detecting a broad range of concentrations in transformer oil. Such a sensor can signal a warning when sparks inside a high voltage power transformer decompose the transformer oil over a long period.

  15. Understanding Hydrothermal Dechlorination of PVC by Focusing on the Operating Conditions and Hydrochar Characteristics

    Directory of Open Access Journals (Sweden)

    Tian Li

    2017-03-01

    Full Text Available To remove chlorine from chlorinated wastes efficiently, the hydrothermal treatment (HT of PVC was investigated with a lower alkaline dosage in this work. Some typical operating conditions were investigated to find out the most important factor affecting the dechlorination efficiency (DE. The FTIR technique was employed to detect the functional groups in PVC and hydrochars generated to reveal the possible pathways for chlorine removal. The results show that the HT temperature was a key parameter to control the dechlorination reaction rate. At a HT temperature of 240 °C, about 94.3% of chlorine could be removed from the PVC with 1% NaOH. The usage of NaOH was helpful for chlorine removal, while a higher dosage might also hinder this process because of the surface poisoning and coverage of free sites. To some extent, the DE was increased with the residence time. At a residence time of 30 min, the DE reached a maximum of 76.74%. A longer residence time could promote the generation of pores in hydrochar which is responsible for the reduction in DE because of the re-absorption of water-soluble chlorine. According to the FTIR results, the peak intensities of both C=CH and C=C stretching vibrations in hydrochar were increased, while the peak at around 3300 cm−1 representing the –OH group was not obvious, indicating that the dehydrochlorination (elimination reaction was a main route for chlorine removal under these conditions studied in this work.

  16. Effect of extensional cyclic strain on the mechanical and physico-mechanical properties of PVC-NBR/graphite composites

    Directory of Open Access Journals (Sweden)

    2008-12-01

    Full Text Available The variation of electrical resistivity as will as the mechanical properties of PVC (polyvinylchloride-NBR (acrylonitrile butadiene rubber based conductive composites filled with different concentrations of graphite were studied. These samples were studied as function of the constant deformation fatigue test. When the specimen was subjected to a large number of rapidly repeating strain cycles, and different strain amplitudes, the conductivity, σ(T, shows an initial rapid fall followed by dynamic equilibrium. Increasing the number of cycles and strain amplitudes, the conductivity remains almost constant over the temperature range 30–140°C. The equilibrium state between destruction and reconstruction of graphite particles has been detected for all strains of certain values of strain cycles (1000, 2000, 3000, and 4000 cycles for 30% strain amplitude. A preliminary study was done to optimize the possibility to use Conductive Polymer Composites (CPC as a strain sensor and to evaluate its performance by an intrinsic physico-mechanical modification measurement. The electromechanical characterization was performed to demonstrate the adaptability and the correct functioning of the sensor as a strain gauge on the fabric. The coefficient of strain sensitivity (K was measured for 50 phr graphite/PVCNBR vulcanized at 3000 number of strain cycles and 30% strain amplitude. There was a broad maximum of K, with a peak value of 82, which was much higher, compared to conventional wire resistors. A slight hysteresis was observed at unloading due to plasticity of the matrix. A good correlation exists between mechanical and electrical response to the strain sensitivity. Mechanical reinforcement was in accordance with the Quemada equation [1] and Guth model [2] attested to good particle-matrix adhesion. It was found that the viscous component of deformation gradually disappeared and the hardening occurred with increasing strain cycles. The modulus, fracture

  17. 1H-NMR/13C-NMR studies of branched structures in PVC obtained at atmospheric pressure

    International Nuclear Information System (INIS)

    Braun, D.; Holzer, G.; Hjertberg, T.

    1981-01-01

    The 1 H-NMR-spectra of raw poly (vinyl cloride) obtained at atmospheric pressure (U-PVC) have revealed the presence of high concentrations of branches. The content of labile chlorine was determined by reaction with phenole in order to estimate the branch points with tertiary chlorine. The branch length of reductively dehalogenated U-PVC by 13 C-NMR analysis have provided evidence for both short chain branches including chloromethyl groups and 2.4-dichloro-n-butyl groups and long chain branching. For a number of U-polymers the total amount of branching ranges from 7.5 to 13.5/1000 C. The 13 C-NMR measurements point to a ratio of methyl/butyl branches of 1:1 and short chains/long chains of 6:1. (orig.)

  18. A novel, fast responding, low noise potentiometric sensor containing a carbon-based polymeric membrane for measuring surfactants in industrial and environmental applications.

    Science.gov (United States)

    Samardžić, Mirela; Galović, Olivera; Hajduković, Mateja; Sak-Bosnar, Milan

    2017-01-01

    A new high-sensitivity potentiometric sensor for anionic surfactants was fabricated using the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion associate as an ionophore that was incorporated into a liquid PVC membrane. Carbon powder was used for immobilization of the ionophore in the membrane, thus significantly reducing its ohmic resistance and reducing its signal drift. The sensor exhibits a sub-Nernstian response for both dodecylbenzenesulfonate (DBS) and dodecyl sulfate (DS) in H 2 O (55.3 and 58.5mV/decade of activity, respectively) in a range between 3.2×10 -7 and 4.6×10 -3 M for DS and 2.5×10 -7 and 1.2×10 -3 M for DBS. The sensor also exhibited a sub-Nernstian response for DS and DBS in 10mM Na 2 SO 4 (55.4 and 57.7mV/decade of activity, respectively) between 2.5×10 -7 and 4.6×10 -3 M for DS and 1.5×10 -7 and 8.8×10 -4 M for DBS. The detection limits for DS and DBS in H 2 O were 2.5×10 -7 and 2.0×10 -7 M and in 10mM Na 2 SO 4 the detection limits were 2.5×10 -7 and 1.2×10 -7 M, respectively. The response time of the sensor was less than 5s for changes at higher concentration levels (above 1×10 -4 M) in both water and 10mM Na 2 SO 4. At lower concentrations (below 1×10 -5 M) the response times were 8 and 6s in water and 10mM Na 2 SO 4 , respectively. The signal drift of the sensor was 1.2mV/hour. The new carbon-based sensor exhibited excellent selectivity performance for DS over almost all of the anions commonly present in commercial formulations and it was successfully employed as an end-point detector in potentiometric titrations of anionic surfactants in a pH range from 3 to 12. Three-component mixtures containing sodium alkanesulfonate (C 10 , C 12 and C 14 ) were successfully differentially titrated. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. A Solar Position Sensor Based on Image Vision.

    Science.gov (United States)

    Ruelas, Adolfo; Velázquez, Nicolás; Villa-Angulo, Carlos; Acuña, Alexis; Rosales, Pedro; Suastegui, José

    2017-07-29

    Solar collector technologies operate with better performance when the Sun beam direction is normal to the capturing surface, and for that to happen despite the relative movement of the Sun, solar tracking systems are used, therefore, there are rules and standards that need minimum accuracy for these tracking systems to be used in solar collectors' evaluation. Obtaining accuracy is not an easy job, hence in this document the design, construction and characterization of a sensor based on a visual system that finds the relative azimuth error and height of the solar surface of interest, is presented. With these characteristics, the sensor can be used as a reference in control systems and their evaluation. The proposed sensor is based on a microcontroller with a real-time clock, inertial measurement sensors, geolocation and a vision sensor, that obtains the angle of incidence from the sunrays' direction as well as the tilt and sensor position. The sensor's characterization proved how a measurement of a focus error or a Sun position can be made, with an accuracy of 0.0426° and an uncertainty of 0.986%, which can be modified to reach an accuracy under 0.01°. The validation of this sensor was determined showing the focus error on one of the best commercial solar tracking systems, a Kipp & Zonen SOLYS 2. To conclude, the solar tracking sensor based on a vision system meets the Sun detection requirements and components that meet the accuracy conditions to be used in solar tracking systems and their evaluation or, as a tracking and orientation tool, on photovoltaic installations and solar collectors.

  20. Experimental Investigation on Admittance-Based Piezoelectric Sensor Diagnostic Process

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Hyejin; Park, Tongil; Park, Gyuhae [Chonnam National University, Gwangju (Korea, Republic of)

    2015-01-15

    Structural health monitoring (SHM) techniques based on the use of active-sensing piezoelectric (PZT) materials have received considerable attention. The validation of the PZT functionality during SHM operation is critical to successfully implementing a reliable SHM system. In this study, we investigated several parameters that affect the admittance-based sensor diagnostic process. We experimentally identified the temperature dependency of the active-sensor diagnostic process. We found that the admittance-based sensor diagnostic process can differentiate the adhesion conditions of bonding materials that are used to install a PZT on a structure, which is important when designing a sensor diagnostic process for an SHM system.

  1. A Survey of Model-based Sensor Data Acquisition and Management

    OpenAIRE

    Aggarwal, Charu C.; Sathe, Saket; Papaioannou, Thanasis; Jeung, Hoyoung; Aberer, Karl

    2013-01-01

    In recent years, due to the proliferation of sensor networks, there has been a genuine need of researching techniques for sensor data acquisition and management. To this end, a large number of techniques have emerged that advocate model-based sensor data acquisition and management. These techniques use mathematical models for performing various, day-to-day tasks involved in managing sensor data. In this chapter, we survey the state-of-the-art techniques for model-based sensor data acquisition...

  2. Fully wireless pressure sensor based on endoscopy images

    Science.gov (United States)

    Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni

    2018-04-01

    In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.

  3. LPG based all plastic pressure sensor

    DEFF Research Database (Denmark)

    Bundalo, Ivan-Lazar; Lwin, R.; Leon-Saval, S.

    2015-01-01

    A prototype all-plastic pressure sensor is presented and characterized for potential use as an endoscope. The sensor is based on Long Period Gratings (LPG) inscribed with a CO2 laser in 6-ring microstructured PMMA fiber. Through a latex coated, plastic 3D-printed transducer pod, external pressure...... is converted to longitudinal elongation of the pod and therefore of the fiber containing the LPG. The sensor has been characterised for pressures of up to 160 mBar in an in-house built pressure chamber. Furthermore, the influence of the fiber prestrain, fiber thickness and the effect of different glues...

  4. Electrode-analytical properties of polyvinylchloride membranes based on triple metal-polymeric complexes

    Directory of Open Access Journals (Sweden)

    Katerina V. Matorina

    2015-10-01

    Full Text Available The influence of the nature of the electrode-active substances (EAS, the composition of the external and internal solutions on the formation of the analytical signal of polyvinylchloride (PVC membranes based on associates and triple metal-polymeric complexes (TMPC was established. Dehumidification of synthesized membranes increases with the content of polyvinylpyrrolidone (PVP. The value of the swelling degree is more than two times greater for membranes, which contain as EAS TMPC, relative to membranes based on associates. The value of water absorption of membranes is determined by the nature of EAS. They formed a series of increasing of the swelling degree such as associate < background membrane < TMPC. Swelling of the background membrane is explained by the physical sorption of water molecules on the surface of plasticized membrane. Hydration of PVP macromolecules varies with the introduction of metal ions, macromolecules unit undergoes a conformational transition. PVP macromolecules form tunnels or cavities where complex particles distributed and additional water accumulated through the second coordination layer. Constructed sensors based on TMPC have slope of electrode function equal to 25 mV/pC. Linear dependence of potential on the polymer concentration is observed in the range of 5–7 pC units. Sensors based on associates have slope of the electrode function of 20–25 mV/pC that can be varied depending on the nature of the EAS. Working range is 4–8 pC. Response time of sensor is less than 1 min. The optimal time for conditioning of the synthesized PVC membrane is 24 hours. Potentiometric sensors have been developed for the determination of residual amounts of low molecular PVP which is a food additive E 1201 commonly used for thickening, stabilizing and clarifying of food products. The content of PVP was determined in real objects (apple juice, beer, red wine and cognac with using the polyvinylpyrrolidone sensors (Sr < 0.08. The

  5. PVC esaslı CTP kesme atığı dolgulu malzemelerin termal özelliklerinin incelenmesi

    Directory of Open Access Journals (Sweden)

    Arzu Özüyağlı

    2016-08-01

    Full Text Available Bu çalışmada, PVC üretiminde kullanılan CaCO3 dolgu malzemesi yerine, sanayi atığı kullanılması sonucu termal özelliklerdeki değişim araştırılmıştır. Kullanılan sanayi atığı CTP boru üretiminden sulu kesim sırasında çıkmakta ve SiO2, cam elyaf ve polyester reçine içermektedir. Sulu çamur halinde filtre presten çıkan atık fabrikadan alındıktan sonra kurutma ve eleme işlemleri uygulanarak toz formuna getirilmiştir. Numuneler PVC, CTP atık tozu ve prosese yardımcı maddeler mikserde karıştırılarak ekstrüzyon yöntemi ile profil şeklinde üretilmiştir. Atık toz PVC’ye oranla ağırlıkça %5-%70 oranlarında dolgu malzemesi olarak kullanılmıştır. Kalsit (CaCO3 katkılı ve katkısız PVC numuneleri de benzer proses parametreleri kullanılarak üretilmiştir. Üretilen numuneler, seramik krozeler kullanılarak DTA-TG analizleri yapılmıştır.

  6. Estudo Comparativo dos custos e aquisição de PVC no Brasil: mercado interno versus importação

    Directory of Open Access Journals (Sweden)

    André Bueno Borges

    2015-10-01

    Full Text Available A pesquisa tem por objetivo mapear o processo de aquisição analisando os custos para venda de PVC no Brasil. Portanto, foi realizado um estudo comparativo dos custos e tributações dos processos de importação. As cotações do preço do PVC são extraídas do site ICIS Pricing que é o maior fornecedor de informações de mercado petroquímico do mundo. A produção nacional do PVC é menor do que o consumo, fazendo com que a importação do produto seja frequente pelas empresas transformadoras de plástico. Pelo trabalho exposto, observa-se que os benefícios resultantes da pesquisa de preço do produto no mercado mundial. Foi demonstrado que o produto importado da China ou dos Estados Unidos apresenta valores em torno de 20% menores do que o praticado no mercado nacional.

  7. Circuit Design of Surface Acoustic Wave Based Micro Force Sensor

    Directory of Open Access Journals (Sweden)

    Yuanyuan Li

    2014-01-01

    Full Text Available Pressure sensors are commonly used in industrial production and mechanical system. However, resistance strain, piezoresistive sensor, and ceramic capacitive pressure sensors possess limitations, especially in micro force measurement. A surface acoustic wave (SAW based micro force sensor is designed in this paper, which is based on the theories of wavelet transform, SAW detection, and pierce oscillator circuits. Using lithium niobate as the basal material, a mathematical model is established to analyze the frequency, and a peripheral circuit is designed to measure the micro force. The SAW based micro force sensor is tested to show the reasonable design of detection circuit and the stability of frequency and amplitude.

  8. All-solid-state potentiometric sensors for ascorbic acid by using a screen-printed compatible solid contact

    International Nuclear Information System (INIS)

    Veltsistas, Panayotis G.; Prodromidis, Mamas I.; Efstathiou, Constantinos

    2004-01-01

    The development of all-solid-state potentiometric ion selective electrodes for monitoring of ascorbic acid, by using a screen-printed compatible solid contact is described. The applied methodology is based on the use of PVC membrane modified with some firstly-tested ionophores (triphenyltin(IV)chloride, triphenyltin(IV)hydroxide and palmitoyl-L-ascorbic acid) and a novel one synthesized in our laboratory (dibutyltin(IV) diascorbate). Synthesis protocol and some preliminary identification studies are given. A conductive graphite-based polymer thick film ink was used as an internal solid contact between the graphite electrode and the PVC membrane. The presence and the nature of the solid contact (plain or doped with lanthanum 2,6-dichlorophenolindophenol (DCPI)) seem to enhance the analytical performance of the electrodes in terms of sensitivity, dynamic range, and response time. The analytical performance of the constructed electrodes was evaluated with potentiometry, constant-current chronopotentiometry and electrochemical impedance spectroscopy (EIS). The interference effect of various compounds was also tested. The potential response of the optimized Ph 3 SnCl-based electrode was linear against ascorbic acid concentration range 0.005-5.0 mM. The applicability of the proposed sensors in real samples was also tested. The detection limit was 0.002 mM ascorbic acid (50 mM phosphate, pH 5 in 50 mM KCl). The slope of the electrodes was super-Nernstian and pH dependent, indicating a mechanism involving a combination of charge transfer and ion exchange processes. Fabrication of screen-printed ascorbate ISEs has also been demonstrated

  9. Analysis of Polyadipate Ester Content in PVC Plastics by Means of FT-Raman Spectroscopy

    DEFF Research Database (Denmark)

    Berg, Rolf W.

    2006-01-01

    Plasticizers are needed in flexible PVC (PolyVinylChloride) products. There is serious concern that commonly used phthalate esters may harm life reproduction systems. To avoid the problems, instead adipate di-esters (AEs) of C8 to C10 alcohols are used as higher prized alternatives; e.g. di-2......-ethylhexyl adipate or DEHA [103-23-1], also known as Adimoll or di-octyl adipate, DOA. A widely used plasticizer in food (cling) films is DEHA, often in combination with polymers, epoxidized soya-bean oil, etcetera. DEHA also occurs in children toys. We have previously shown that the presence of phthalate...... esters in PVC can be rapidly analyzed by Fourier transform (FT-) Raman spectroscopy excited with a 1064 nm laser. Here in this project we report a similar study. The aim was to find out whether FT-Raman spectroscopy can be used to determine the presence of adipate esters (AEs) as plasticizers...

  10. Dehydrohalogenation during pyrolysis of brominated flame retardant containing high impact polystyrene (HIPS-Br) mixed with polyvinylchloride (PVC)

    Energy Technology Data Exchange (ETDEWEB)

    Uddin, M.A.; Bhaskar, T.; Kaneko, J.; Muto, A.; Sakata, Y.; Matsui, T. [Okayama University, Okayama (Japan). Dept. of Applied Chemistry, Faculty of Engineering

    2002-09-01

    Dehydrohalogenation during pyrolysis of brominated flame retardant containing polystyrene (brominated high impact polystyrene (HIPS-Br)) mixed with polyvinylchloride (PVC) was carried out in a laboratory scale batch process. Thermal and catalytic degradation of HIPS-Br mixed with PVBC on carbon composite of iron oxide (TR-00301) catalyst was investigated. The thermal degradation of waste plastics (HIPS-Br/PVC) yielded liquid products with 55,000 ppm bromine and 4300 ppm chlorine content in oil. Catalytic degradation (4 g; TR-00301) of HIPS-Br/PVC waste plastics at 430{degree}C produced halogen-free clean oil, which can be used as a fuel oil or chemical feedstock. The main liquid products during catalytic degradation were benzene, toluene, styrene, ethyl benzene, {alpha}-methyl styrene, butyl benzene, 1,2-dimethyl benzene etc. The average carbon number of the liquid products produced during catalytic degradation (9.3) of waste plastics was less than that of the thermal degradation (10.4) and the density of liquid products was found to be lower during the catalytic degradation than the thermal degradation. The possibility of a single step catalytic process for the conversion of halogenated waste plastics into fuel oil with the simultaneous removal of chlorine and bromine content form the oil was demonstrated. 21 refs., 7 figs., 2 tabs.

  11. ISFET based enzyme sensors

    NARCIS (Netherlands)

    van der Schoot, Bart H.; Bergveld, Piet

    1987-01-01

    This paper reviews the results that have been reported on ISFET based enzyme sensors. The most important improvement that results from the application of ISFETs instead of glass membrane electrodes is in the method of fabrication. Problems with regard to the pH dependence of the response and the

  12. A physical probabilistic model to predict failure rates in buried PVC pipelines

    International Nuclear Information System (INIS)

    Davis, P.; Burn, S.; Moglia, M.; Gould, S.

    2007-01-01

    For older water pipeline materials such as cast iron and asbestos cement, future pipe failure rates can be extrapolated from large volumes of existing historical failure data held by water utilities. However, for newer pipeline materials such as polyvinyl chloride (PVC), only limited failure data exists and confident forecasts of future pipe failures cannot be made from historical data alone. To solve this problem, this paper presents a physical probabilistic model, which has been developed to estimate failure rates in buried PVC pipelines as they age. The model assumes that under in-service operating conditions, crack initiation can occur from inherent defects located in the pipe wall. Linear elastic fracture mechanics theory is used to predict the time to brittle fracture for pipes with internal defects subjected to combined internal pressure and soil deflection loading together with through-wall residual stress. To include uncertainty in the failure process, inherent defect size is treated as a stochastic variable, and modelled with an appropriate probability distribution. Microscopic examination of fracture surfaces from field failures in Australian PVC pipes suggests that the 2-parameter Weibull distribution can be applied. Monte Carlo simulation is then used to estimate lifetime probability distributions for pipes with internal defects, subjected to typical operating conditions. As with inherent defect size, the 2-parameter Weibull distribution is shown to be appropriate to model uncertainty in predicted pipe lifetime. The Weibull hazard function for pipe lifetime is then used to estimate the expected failure rate (per pipe length/per year) as a function of pipe age. To validate the model, predicted failure rates are compared to aggregated failure data from 17 UK water utilities obtained from the United Kingdom Water Industry Research (UKWIR) National Mains Failure Database. In the absence of actual operating pressure data in the UKWIR database, typical

  13. A MEMS SOI-based piezoresistive fluid flow sensor

    Science.gov (United States)

    Tian, B.; Li, H. F.; Yang, H.; Song, D. L.; Bai, X. W.; Zhao, Y. L.

    2018-02-01

    In this paper, a SOI (silicon-on-insulator)-based piezoresistive fluid flow sensor is presented; the presented flow sensor mainly consists of a nylon sensing head, stainless steel cantilever beam, SOI sensor chip, printed circuit board, half-cylinder gasket, and stainless steel shell. The working principle of the sensor and some detailed contrastive analysis about the sensor structure were introduced since the nylon sensing head and stainless steel cantilever beam have distinct influence on the sensor performance; the structure of nylon sensing head and stainless steel cantilever beam is also discussed. The SOI sensor chip was fabricated using micro-electromechanical systems technologies, such as reactive ion etching and low pressure chemical vapor deposition. The designed fluid sensor was packaged and tested; a calibration installation system was purposely designed for the sensor experiment. The testing results indicated that the output voltage of the sensor is proportional to the square of the fluid flow velocity, which is coincident with the theoretical derivation. The tested sensitivity of the sensor is 3.91 × 10-4 V ms2/kg.

  14. Flow Injection Potentiometric Determination of Cd2+ Ions Using a Coated Graphite Plasticized PVC-Membrane Electrode Based on 1, 3-Bis(2-cyanobenzene)triazene.

    Science.gov (United States)

    Shamsipur, Mojtaba; Sahari, Shokat; Payehghadr, Mahmood; Alizadeh, Kamal

    2011-09-01

    1, 3-Bis(2-cyanobenzene)triazene, L, was used as a suitable ionophore for the fabrication of a new PVC-based polymeric membrane coated graphite electrode for selective sensing of Cd2+ ion. The electrode exhibited a selective linear Nernstian response to Cd2+ ion at an optimal pH range of 6-9 with a limit of detection of 8.0 × 10-6 M and a fast response time of about 2 s. The electrode was used as a proper detection system in flow-injection potentiometry of cadmium ion and resulted in well defined peaks for cadmium ions with stable baseline, excellent reproducibility and high sampling rates of over 100 injections per hour. It showed good stability, reproducibility and fast response time. The practical utility of the proposed system has also been reported.

  15. Comparative acute toxicity of leachates from plastic products made of polypropylene, polyethylene, PVC, acrylonitrile-butadiene-styrene, and epoxy to Daphnia magna.

    Science.gov (United States)

    Lithner, Delilah; Nordensvan, Ildikó; Dave, Göran

    2012-06-01

    The large global production of plastics and their presence everywhere in the society and the environment create a need for assessing chemical hazards and risks associated with plastic products. The aims of this study were to determine and compare the toxicity of leachates from plastic products made of five plastics types and to identify the class of compounds that is causing the toxicity. Selected plastic types were those with the largest global annual production, that is, polypropylene, polyethylene, and polyvinyl chloride (PVC), or those composed of hazardous monomers (e.g., PVC, acrylonitrile-butadiene-styrene [ABS], and epoxy). Altogether 26 plastic products were leached in deionized water (3 days at 50°C), and the water phases were tested for acute toxicity to Daphnia magna. Initial Toxicity Identification Evaluations (C18 filtration and EDTA addition) were performed on six leachates. For eleven leachates (42%) 48-h EC50s (i.e the concentration that causes effect in 50 percent of the test organisms) were below the highest test concentration, 250 g plastic/L. All leachates from plasticized PVC (5/5) and epoxy (5/5) products were toxic (48-h EC50s ranging from 2 to 235 g plastic/L). None of the leachates from polypropylene (5/5), ABS (5/5), and rigid PVC (1/1) products showed toxicity, but one of the five tested HDPE leachates was toxic (48-h EC50 17-24 g plastic/L). Toxicity Identification Evaluations indicated that mainly hydrophobic organics were causing the toxicity and that metals were the main cause for one leachate (metal release was also confirmed by chemical analysis). Toxic chemicals leached even during the short-term leaching in water, mainly from plasticized PVC and epoxy products.

  16. Possibility of the use of PVC plastics as a ray dosemeter

    International Nuclear Information System (INIS)

    Amri Ayat; Sutrisno Puspodikoro.

    1978-01-01

    The use of plastics as a radiation dosemeter for measurement of γ-rays is very attractive to be studied. In the work presented here commercial PVC film with the trade-mark ''Takiron'' is used for Co-60 radiation dosimetry. According to the experiments the useful dose range extends over 0.15-1.2 Mrads. Fading of the coloration with time after radiation exposure can be stabilised by heat treatment (60 deg C for 30 minutes). (author)

  17. Development of a Waterproof Crack-Based Stretchable Strain Sensor Based on PDMS Shielding

    Directory of Open Access Journals (Sweden)

    Seong Kyung Hong

    2018-04-01

    Full Text Available This paper details the design of a poly(dimethylsiloxane (PDMS-shielded waterproof crack-based stretchable strain sensor, in which the electrical characteristics and sensing performance are not influenced by changes in humidity. This results in a higher number of potential applications for the sensor. A previously developed omni-purpose stretchable strain (OPSS sensor was used as the basis for this work, which utilizes a metal cracking structure and provides a wide sensing range and high sensitivity. Changes in the conductivity of the OPSS sensor, based on humidity conditions, were investigated along with the potential possibility of using the design as a humidity sensor. However, to prevent conductivity variation, which can decrease the reliability and sensing ability of the OPSS sensor, PDMS was utilized as a shielding layer over the OPSS sensor. The PDMS-shielded OPSS sensor showed approximately the same electrical characteristics as previous designs, including in a high humidity environment, while maintaining its strain sensing capabilities. The developed sensor shows promise for use under high humidity conditions and in underwater applications. Therefore, considering its unique features and reliable sensing performance, the developed PDMS-shielded waterproof OPSS sensor has potential utility in a wide range of applications, such as motion monitoring, medical robotics and wearable healthcare devices.

  18. Development of a Waterproof Crack-Based Stretchable Strain Sensor Based on PDMS Shielding.

    Science.gov (United States)

    Hong, Seong Kyung; Yang, Seongjin; Cho, Seong J; Jeon, Hyungkook; Lim, Geunbae

    2018-04-12

    This paper details the design of a poly(dimethylsiloxane) (PDMS)-shielded waterproof crack-based stretchable strain sensor, in which the electrical characteristics and sensing performance are not influenced by changes in humidity. This results in a higher number of potential applications for the sensor. A previously developed omni-purpose stretchable strain (OPSS) sensor was used as the basis for this work, which utilizes a metal cracking structure and provides a wide sensing range and high sensitivity. Changes in the conductivity of the OPSS sensor, based on humidity conditions, were investigated along with the potential possibility of using the design as a humidity sensor. However, to prevent conductivity variation, which can decrease the reliability and sensing ability of the OPSS sensor, PDMS was utilized as a shielding layer over the OPSS sensor. The PDMS-shielded OPSS sensor showed approximately the same electrical characteristics as previous designs, including in a high humidity environment, while maintaining its strain sensing capabilities. The developed sensor shows promise for use under high humidity conditions and in underwater applications. Therefore, considering its unique features and reliable sensing performance, the developed PDMS-shielded waterproof OPSS sensor has potential utility in a wide range of applications, such as motion monitoring, medical robotics and wearable healthcare devices.

  19. A frequency output ferroelectric phase PNZT capacitor-based temperature sensor

    KAUST Repository

    Khan, Naveed

    2016-09-05

    In this paper, a frequency output temperature sensor based on a 4% Niobium doped 20/80 Zr/Ti Lead Zirconate Titanate (PNZT) capacitor is proposed. The sensor capacitance vs temperature and capacitance vs voltage characteristics are experimentally measured below the Curie temperature of the ferroelectric capacitor. The capacitance of the 20/80 (Zr/Ti) composition PNZT capacitor changes by 29% for a temperature change from 10°C to 100°C, which translates to 0.32%/°C temperature sensitivity. The measured sensor characteristics show less than ∼0.7°C deviation from the ideal linear response. A Wien bridge oscillator based temperature sensor is demonstrated based on the PNZT capacitors. Mathematical analysis for the effect of the op-amp finite unity-gain frequency on the sensor circuit oscillation frequency is provided. The experimentally realized frequency output temperature sensor shows -17.6% relative frequency change for a temperature change from 10°C to 100°C. The proposed capacitive temperature sensor can be used in low-power smart sensor nodes without the need for extensive calibration. © 2015 IEEE.

  20. Microbial BOD sensors based on Zr (IV)-loaded collagen fiber.

    Science.gov (United States)

    Zhao, Lei; He, Li; Chen, Shujuan; Zou, Likou; Zhou, Kang; Ao, Xiaolin; Liu, Shuliang; Hu, Xinjie; Han, Guoquan

    2017-03-01

    Biochemical oxygen demand (BOD) sensors based on Zr (IV)-loaded collagen fiber (ZrCF), a novel material with great porous structure, were developed. This novel material shows adsorbability by microorganisms. Saccharomyces cerevisiae and Escherichia coli were used for the construction of BOD sensors. Factors affecting BOD sensor performance were examined. The ZrCF-based BOD sensor showed different sensitivities and linear response ranges with different biofilm densities. The amount of microorganisms strongly affected the performance of the BOD sensor. Poor permeability of previously reported immobilization carriers were greatly circumvented by ZrCF. The service life of the ZrCF-based BOD sensor was more than 42 days. The immobilized microorganisms can be stored for more than 6 months under 4°C in PB solution. There was good correlation between the results of the sensor method and the standard 5-day BOD method in the determination of pure organic substrates and real water samples. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Integrated Temperature Sensors based on Heat Diffusion

    NARCIS (Netherlands)

    Van Vroonhoven, C.P.L.

    2015-01-01

    This thesis describes the theory, design and implementation of a new class of integrated temperature sensors, based on heat diffusion. In such sensors, temperature is sensed by measuring the time it takes for heat to diffuse through silicon. An on-chip thermal delay can be determined by geometry and

  2. Hydrogen sensor based on palladium-yttrium alloy nanosheet

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Boyi [Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, QLD 4111 (Australia); Zhu, Yong, E-mail: y.zhu@griffith.edu.au [Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, QLD 4111 (Australia); Chen, Youping; Song, Han; Huang, Pengcheng [School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074 (China); Dao, Dzung Viet [Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, QLD 4111 (Australia)

    2017-06-15

    This paper presents a hydrogen sensor based on palladium-yttrium (Pd-Y) alloy nanosheet. Zigzag-shaped Pd-Y nanosheet with a thickness of 19.3 nm was deposited on a quartz substrate by using an ultrahigh-vacuum magnetron sputtering system and shadow mask. The atomic ratio of palladium to yttrium in the nanosheet was 0.92/0.08. The fabrication process was simple and low-cost, and the sensor can be mass-produced. The experimental results show the sensor has a superior sensitivity, reversibility, and reproducibility. The resistive-based hydrogen detection mechanism in this research is much simpler and more compact compared to the optical-based detection method. - Highlights: • Pd-Y sensing element was fabricated using a magnetron sputtering system and shadow mask. • The Pd-Y compound consisted of 92% Pd and 8% Y. • The fabrication process was simple, low-cost, and mass-production compatible. • The sensor showed superior sensitivity, reversibility, and reproducibility to hydrogen gas. • The device is more compact than the optical-based counterpart.

  3. Hydrogen sensor based on palladium-yttrium alloy nanosheet

    International Nuclear Information System (INIS)

    Wang, Boyi; Zhu, Yong; Chen, Youping; Song, Han; Huang, Pengcheng; Dao, Dzung Viet

    2017-01-01

    This paper presents a hydrogen sensor based on palladium-yttrium (Pd-Y) alloy nanosheet. Zigzag-shaped Pd-Y nanosheet with a thickness of 19.3 nm was deposited on a quartz substrate by using an ultrahigh-vacuum magnetron sputtering system and shadow mask. The atomic ratio of palladium to yttrium in the nanosheet was 0.92/0.08. The fabrication process was simple and low-cost, and the sensor can be mass-produced. The experimental results show the sensor has a superior sensitivity, reversibility, and reproducibility. The resistive-based hydrogen detection mechanism in this research is much simpler and more compact compared to the optical-based detection method. - Highlights: • Pd-Y sensing element was fabricated using a magnetron sputtering system and shadow mask. • The Pd-Y compound consisted of 92% Pd and 8% Y. • The fabrication process was simple, low-cost, and mass-production compatible. • The sensor showed superior sensitivity, reversibility, and reproducibility to hydrogen gas. • The device is more compact than the optical-based counterpart.

  4. Flexible Graphene-Based Wearable Gas and Chemical Sensors.

    Science.gov (United States)

    Singh, Eric; Meyyappan, M; Nalwa, Hari Singh

    2017-10-11

    Wearable electronics is expected to be one of the most active research areas in the next decade; therefore, nanomaterials possessing high carrier mobility, optical transparency, mechanical robustness and flexibility, lightweight, and environmental stability will be in immense demand. Graphene is one of the nanomaterials that fulfill all these requirements, along with other inherently unique properties and convenience to fabricate into different morphological nanostructures, from atomically thin single layers to nanoribbons. Graphene-based materials have also been investigated in sensor technologies, from chemical sensing to detection of cancer biomarkers. The progress of graphene-based flexible gas and chemical sensors in terms of material preparation, sensor fabrication, and their performance are reviewed here. The article provides a brief introduction to graphene-based materials and their potential applications in flexible and stretchable wearable electronic devices. The role of graphene in fabricating flexible gas sensors for the detection of various hazardous gases, including nitrogen dioxide (NO 2 ), ammonia (NH 3 ), hydrogen (H 2 ), hydrogen sulfide (H 2 S), carbon dioxide (CO 2 ), sulfur dioxide (SO 2 ), and humidity in wearable technology, is discussed. In addition, applications of graphene-based materials are also summarized in detecting toxic heavy metal ions (Cd, Hg, Pb, Cr, Fe, Ni, Co, Cu, Ag), and volatile organic compounds (VOCs) including nitrobenzene, toluene, acetone, formaldehyde, amines, phenols, bisphenol A (BPA), explosives, chemical warfare agents, and environmental pollutants. The sensitivity, selectivity and strategies for excluding interferents are also discussed for graphene-based gas and chemical sensors. The challenges for developing future generation of flexible and stretchable sensors for wearable technology that would be usable for the Internet of Things (IoT) are also highlighted.

  5. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    Energy Technology Data Exchange (ETDEWEB)

    Elhefnawy, O.A. [Nuclear and Radiological Regulatory Authority (NRRA), Cairo (Egypt). Nuclear Safeguards and Physical Protection Dept.

    2017-07-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  6. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    International Nuclear Information System (INIS)

    Elhefnawy, O.A.

    2017-01-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  7. Review of the use of rigid and high-impact PVC pipes in natural gas distribution systems in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Mutter, F; Benjamin, P

    1974-08-01

    Because of a number of instances of stress corrosion cracking or crazing occurring in PVC pipes used in Dutch gas distribution systems, VEG-GASINSTITUUT began an intensive investigation of rigid PVC pipes and high-impact pipes in distribution use under various conditions and with varying service lives. The work led to an investigation of laboratory testing techniques in which the stress-cracking phenomenon found in practice could be duplicated under controllable conditions. Pipes of various materials were examined for their resistance to stress cracking, then this resistance was compared with other long- and short-term physical properties of the material.

  8. Progress in triboluminescence-based smart optical sensor system

    International Nuclear Information System (INIS)

    Olawale, David O.; Dickens, Tarik; Sullivan, William G.; Okoli, Okenwa I.; Sobanjo, John O.; Wang, Ben

    2011-01-01

    Extensive research work has been done in recent times to apply the triboluminescence (TL) phenomenon for damage detection in engineering structures. Of particular note are the various attempts to apply it in the detection of impact damages in composites and aerospace structures. This is because TL-based sensor systems have a great potential for wireless, in-situ and distributed (WID) structural health monitoring when fully developed. This review article highlights development and the current state-of-the-art in the application of TL-based sensor systems. The underlying mechanisms believed to be responsible for triboluminescence, particularly in zinc sulfide manganese, a highly triboluminescent material, are discussed. The challenges militating against the full exploitation and field application of TL sensor systems are also identified. Finally, viable solutions and approaches to address these challenges are enumerated. - Highlights: → The underlying mechanisms believed to be responsible for triboluminescence. → State-of-the-art in the development and application of TL-based sensor systems. → The challenges militating against the full exploitation and field application of TL sensor systems are identified. → Viable solutions and approaches to address these challenges are enumerated.

  9. Preparação de argila modificada com cloreto de cetilpiridíneo e avaliação da interação desta com o PVC Preparation of modified clay with cetylpyridinium chloride and evaluation of their interaction with PVC

    Directory of Open Access Journals (Sweden)

    Daniel K. Resende

    2010-09-01

    Full Text Available Foi preparada uma argila modificada com cloreto de cetilpiridíneo a partir da argila sódica por troca de cátions em solução. Foi avaliada a quantidade de agente de modificação em relação à argila sódica e o tempo reacional. Os materiais obtidos foram caracterizados por difração de raio X (XRD, análise termogravimétrica (TGA e ressonância magnética nuclear (RMN de baixo campo. Após a caracterização foi confirmada a modificação da argila e, também, foi verificado que o produto obtido pode ser empregado na preparação de nanocompósitos de PVC, considerando que o início da degradação do material preparado ocorreu em temperatura superior às comumente utilizadas no processamento do polímero. A adição da argila modificada apresentou uma dispersão adequada no PVC e manteve o início da degradação do material em temperatura compatível com o processamento do polímero, gerando um nanocompósito com parte esfoliada e intercalada.A modified silicate with cetylpyridinium was prepared from sodium clay with cation exchange in solution. The amount of modification agent for clay and the reaction time were evaluated. The materials produced were characterized using X ray diffraction (XRD, termogravimetric analysis (TGA and low field nuclear magnetic resonance (NMR. The formation of new organic clay was confirmed, which was introduced in PVC for the formation of nanocomposites. The beginning of degradation of the new clay occurred at temperatures higher than commonly used in the processing of PVC. The nanocomposites were partially exfoliated and partially intercalated.

  10. Applying Sensor-Based Technology to Improve Construction Safety Management.

    Science.gov (United States)

    Zhang, Mingyuan; Cao, Tianzhuo; Zhao, Xuefeng

    2017-08-11

    Construction sites are dynamic and complicated systems. The movement and interaction of people, goods and energy make construction safety management extremely difficult. Due to the ever-increasing amount of information, traditional construction safety management has operated under difficult circumstances. As an effective way to collect, identify and process information, sensor-based technology is deemed to provide new generation of methods for advancing construction safety management. It makes the real-time construction safety management with high efficiency and accuracy a reality and provides a solid foundation for facilitating its modernization, and informatization. Nowadays, various sensor-based technologies have been adopted for construction safety management, including locating sensor-based technology, vision-based sensing and wireless sensor networks. This paper provides a systematic and comprehensive review of previous studies in this field to acknowledge useful findings, identify the research gaps and point out future research directions.

  11. Real-time two-dimensional imaging of potassium ion distribution using an ion semiconductor sensor with charged coupled device technology.

    Science.gov (United States)

    Hattori, Toshiaki; Masaki, Yoshitomo; Atsumi, Kazuya; Kato, Ryo; Sawada, Kazuaki

    2010-01-01

    Two-dimensional real-time observation of potassium ion distributions was achieved using an ion imaging device based on charge-coupled device (CCD) and metal-oxide semiconductor technologies, and an ion selective membrane. The CCD potassium ion image sensor was equipped with an array of 32 × 32 pixels (1024 pixels). It could record five frames per second with an area of 4.16 × 4.16 mm(2). Potassium ion images were produced instantly. The leaching of potassium ion from a 3.3 M KCl Ag/AgCl reference electrode was dynamically monitored in aqueous solution. The potassium ion selective membrane on the semiconductor consisted of plasticized poly(vinyl chloride) (PVC) with bis(benzo-15-crown-5). The addition of a polyhedral oligomeric silsesquioxane to the plasticized PVC membrane greatly improved adhesion of the membrane onto Si(3)N(4) of the semiconductor surface, and the potential response was stabilized. The potential response was linear from 10(-2) to 10(-5) M logarithmic concentration of potassium ion. The selectivity coefficients were K(K(+),Li(+))(pot) = 10(-2.85), K(K(+),Na(+))(pot) = 10(-2.30), K(K(+),Rb(+))(pot) =10(-1.16), and K(K(+),Cs(+))(pot) = 10(-2.05).

  12. Iron (III Ion Sensor Based on the Seedless Grown ZnO Nanorods in 3 Dimensions Using Nickel Foam Substrate

    Directory of Open Access Journals (Sweden)

    Mazhar Ali Abbasi

    2013-01-01

    Full Text Available In the present work, the seedless, highly aligned and vertical ZnO nanorods in 3 dimensions (3D were grown on the nickel foam substrate. The seedless grown ZnO nanorods were characterised by field emission scanning electron microscopy (FESEM, high resolution transmission electron microscopy (HRTEM, and X-ray diffraction (XRD techniques. The characterised seedless ZnO nanorods in 3D on nickel foam were highly dense, perpendicular to substrate, grown along the (002 crystal plane, and also composed of single crystal. In addition to this, these seedless ZnO nanorods were functionalized with trans-dinitro-dibenzo-18-6 crown ether, a selective iron (III ion ionophore, along with other components of membrane composition such as polyvinyl chloride (PVC, 2-nitopentylphenyl ether as plasticizer (NPPE, and tetrabutyl ammonium tetraphenylborate (TBATPB as conductivity increaser. The sensor electrode has shown high linearity with a wide range of detection of iron (III ion concentrations from 0.005 mM to 100 mM. The low limit of detection of the proposed ion selective electrode was found to be 0.001 mM. The proposed sensor also described high storage stability, selectivity, reproducibility, and repeatability and a quick response time of less than 10 s.

  13. Development of GaN-based micro chemical sensor nodes

    Science.gov (United States)

    Son, Kyung-ah; Prokopuk, Nicholas; George, Thomas; Moon, Jeong S.

    2005-01-01

    Sensors based on III-N technology are gaining significant interest due to their potential for monolithic integration of RF transceivers and light sources and the capability of high temperature operations. We are developing a GaN-based micro chemical sensor node for remote detection of chemical toxins, and present electrical responses of AlGaN/GaN HEMT (High Electron Mobility Transistor) sensors to chemical toxins as well as other common gases.

  14. Optimize Etching Based Single Mode Fiber Optic Temperature Sensor

    OpenAIRE

    Ajay Kumar; Dr. Pramod Kumar

    2014-01-01

    This paper presents a description of etching process for fabrication single mode optical fiber sensors. The process of fabrication demonstrates an optimized etching based method to fabricate single mode fiber (SMF) optic sensors in specified constant time and temperature. We propose a single mode optical fiber based temperature sensor, where the temperature sensing region is obtained by etching its cladding diameter over small length to a critical value. It is observed that th...

  15. A high sensitivity nanomaterial based SAW humidity sensor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, T-T; Chou, T-H [Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan (China); Chen, Y-Y [Department of Mechanical Engineering, Tatung University, Taipei 104, Taiwan (China)], E-mail: wutt@ndt.iam.ntu.edu.tw

    2008-04-21

    In this paper, a highly sensitive humidity sensor is reported. The humidity sensor is configured by a 128{sup 0}YX-LiNbO{sub 3} based surface acoustic wave (SAW) resonator whose operating frequency is at 145 MHz. A dual delay line configuration is realized to eliminate external temperature fluctuations. Moreover, for nanostructured materials possessing high surface-to-volume ratio, large penetration depth and fast charge diffusion rate, camphor sulfonic acid doped polyaniline (PANI) nanofibres are synthesized by the interfacial polymerization method and further deposited on the SAW resonator as selective coating to enhance sensitivity. The humidity sensor is used to measure various relative humidities in the range 5-90% at room temperature. Results show that the PANI nanofibre based SAW humidity sensor exhibits excellent sensitivity and short-term repeatability.

  16. pH sensor based on boron nitride nanotubes.

    Science.gov (United States)

    Huang, Q; Bando, Y; Zhao, L; Zhi, C Y; Golberg, D

    2009-10-14

    A submicrometer-sized pH sensor based on biotin-fluorescein-functionalized multiwalled BN nanotubes with anchored Ag nanoparticles is designed. Intrinsic pH-dependent photoluminescence and Raman signals in attached fluorescein molecules enhanced by Ag nanoparticles allow this novel nanohybrid to perform as a practical pH sensor. It is able to work in a submicrometer-sized space. For example, the sensor may determine the environmental pH of sub-units in living cells where a traditional optical fiber sensor fails because of spatial limitations.

  17. pH sensor based on boron nitride nanotubes

    International Nuclear Information System (INIS)

    Huang, Q; Bando, Y; Zhao, L; Zhi, C Y; Golberg, D

    2009-01-01

    A submicrometer-sized pH sensor based on biotin-fluorescein-functionalized multiwalled BN nanotubes with anchored Ag nanoparticles is designed. Intrinsic pH-dependent photoluminescence and Raman signals in attached fluorescein molecules enhanced by Ag nanoparticles allow this novel nanohybrid to perform as a practical pH sensor. It is able to work in a submicrometer-sized space. For example, the sensor may determine the environmental pH of sub-units in living cells where a traditional optical fiber sensor fails because of spatial limitations.

  18. Development of paper-based electrochemical sensors for water quality monitoring

    Science.gov (United States)

    Smith, Suzanne; Bezuidenhout, Petroné; Mbanjwa, Mesuli; Zheng, Haitao; Conning, Mariette; Palaniyandy, Nithyadharseni; Ozoemena, Kenneth; Land, Kevin

    2016-02-01

    We present a method for the development of paper-based electrochemical sensors for detection of heavy metals in water samples. Contaminated water leads to serious health problems and environmental issues. Paper is ideally suited for point-of-care testing, as it is low cost, disposable, and multi-functional. Initial sensor designs were manufactured on paper substrates using combinations of inkjet printing and screen printing technologies using silver and carbon inks. Bismuth onion-like carbon nanoparticle ink was manufactured and used as the active material of the sensor for both commercial and paper-based sensors, which were compared using standard electrochemical analysis techniques. The results highlight the potential of paper-based sensors to be used effectively for rapid water quality monitoring at the point-of-need.

  19. Poly (Vinyl Chloride Based Ion Selective Electrode for Determination of Zr (IV Ions Based on 2, 6-Dibenzylidenecyclohexanone

    Directory of Open Access Journals (Sweden)

    Syed A. Nabi

    2008-08-01

    Full Text Available A selective poly (vinyl chloride-based membrane sensor using 2,6-Dibenzylidenecyclohexanone as an ionophore have been prepared and explored as Zr (IV selective electrode. The sensitivity, working range and response time shows a significant dependence on the concentration of ionophore. The electrode prepared with 100 mg of PVC, 10 mg of ionophore and 5 ml of dibutylthylate shows the best performance. The electrode works well in the concentration range of 1×10-1-5×10-5 with a nerstian slope 55±2 eV and response time of 18 seconds. The sensor works well over the pH range 3-6. The sensor can be used for the period of over 1 month with out deviation in response characteristics. The selectivity of the electrode was studied and it was found that the electrode exhibited good selectivity for zirconium (IV over some alkaline earth metal ions. The electrode was also used as indicator electrode for potentiometeric titration of Zr (IV ions against EDTA solution.

  20. Sensor fusion-based map building for mobile robot exploration

    International Nuclear Information System (INIS)

    Ribo, M.

    2000-01-01

    To carry out exploration tasks in unknown or partially unknown environments, a mobile robot needs to acquire and maintain models of its environment. In doing so, several sensors of same nature and/or heterogeneous sensor configurations may be used by the robot to achieve reliable performances. However, this in turn poses the problem of sensor fusion-based map building: How to interpret, combine and integrate sensory information in order to build a proper representation of the environment. Specifically, the goal of this thesis is to probe integration algorithms for Occupancy Grid (OG) based map building using odometry, ultrasonic rangefinders, and stereo vision. Three different uncertainty calculi are presented here which are used for sensor fusion-based map building purposes. They are based on probability theory, Dempster-Shafer theory of evidence, and fuzzy set theory. Besides, two different sensor models are depicted which are used to translate sensing data into range information. Experimental examples of OGs built from real data recorded by two robots in office-like environment are presented. They show the feasibility of the proposed approach for building both sonar and visual based OGs. A comparison among the presented uncertainty calculi is performed in a sonar-based framework. Finally, the fusion of both sonar and visual information based of the fuzzy set theory is depicted. (author)

  1. Physiological roles of acid-base sensors.

    Science.gov (United States)

    Levin, Lonny R; Buck, Jochen

    2015-01-01

    Acid-base homeostasis is essential for life. The macromolecules upon which living organisms depend are sensitive to pH changes, and physiological systems use the equilibrium between carbon dioxide, bicarbonate, and protons to buffer their pH. Biological processes and environmental insults are constantly challenging an organism's pH; therefore, to maintain a consistent and proper pH, organisms need sensors that measure pH and that elicit appropriate responses. Mammals use multiple sensors for measuring both intracellular and extracellular pH, and although some mammalian pH sensors directly measure protons, it has recently become apparent that many pH-sensing systems measure pH via bicarbonate-sensing soluble adenylyl cyclase.

  2. Capillarity-based preparation system for optical colorimetric sensor arrays.

    Science.gov (United States)

    Luo, Xiao-Gang; Yi, Xin; Bu, Xiang-Nan; Hou, Chang-Jun; Huo, Dan-Qun; Yang, Mei; Fa, Huan-Bao; Lei, Jin-Can

    2017-03-01

    In recent years, optical colorimetric sensor arrays have demonstrated beneficial features, including rapid response, high selectivity, and high specificity; as a result, it has been extensively applied in food inspection and chemical studies, among other fields. There are instruments in the current market available for the preparation of an optical colorimetric sensor array, but it lacks the corresponding research of the preparation mechanism. Therefore, in connection with the main features of this kind of sensor array such as consistency, based on the preparation method of contact spotting, combined with a capillary fluid model, Washburn equation, Laplace equation, etc., this paper develops a diffusion model of an optical colorimetric sensor array during its preparation and sets up an optical colorimetric sensor array preparation system based on this diffusion model. Finally, this paper compares and evaluates the sensor arrays prepared by the system and prepared manually in three aspects such as the quality of array point, response of array, and response result, and the results show that the performance index of the sensor array prepared by a system under this diffusion model is better than that of the sensor array of manual spotting, which meets the needs of the experiment.

  3. Electrochemical sensors and biosensors based on less aggregated graphene.

    Science.gov (United States)

    Bo, Xiangjie; Zhou, Ming; Guo, Liping

    2017-03-15

    As a novel single-atom-thick sheet of sp 2 hybridized carbon atoms, graphene (GR) has attracted extensive attention in recent years because of its unique and remarkable properties, such as excellent electrical conductivity, large theoretical specific surface area, and strong mechanical strength. However, due to the π-π interaction, GR sheets are inclined to stack together, which may seriously degrade the performance of GR with the unique single-atom layer. In recent years, an increasing number of GR-based electrochemical sensors and biosensors are reported, which may reflect that GR has been considered as a kind of hot and promising electrode material for electrochemical sensor and biosensor construction. However, the active sites on GR surface induced by the irreversible GR aggregations would be deeply secluded inside the stacked GR sheets and therefore are not available for the electrocatalysis. So the alleviation or the minimization of the aggregation level for GR sheets would facilitate the exposure of active sites on GR and effectively upgrade the performance of GR-based electrochemical sensors and biosensors. Less aggregated GR with low aggregation and high dispersed structure can be used in improving the electrochemical activity of GR-based electrochemical sensors or biosensors. In this review, we summarize recent advances and new progress for the development of electrochemical sensors based on less aggregated GR. To achieve such goal, many strategies (such as the intercalation of carbon materials, surface modification, and structural engineering) have been applied to alleviate the aggregation level of GR in order to enhance the performance of GR-based electrochemical sensors and biosensors. Finally, the challenges associated with less aggregated GR-based electrochemical sensors and biosensors as well as related future research directions are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A market-based optimization approach to sensor and resource management

    Science.gov (United States)

    Schrage, Dan; Farnham, Christopher; Gonsalves, Paul G.

    2006-05-01

    Dynamic resource allocation for sensor management is a problem that demands solutions beyond traditional approaches to optimization. Market-based optimization applies solutions from economic theory, particularly game theory, to the resource allocation problem by creating an artificial market for sensor information and computational resources. Intelligent agents are the buyers and sellers in this market, and they represent all the elements of the sensor network, from sensors to sensor platforms to computational resources. These agents interact based on a negotiation mechanism that determines their bidding strategies. This negotiation mechanism and the agents' bidding strategies are based on game theory, and they are designed so that the aggregate result of the multi-agent negotiation process is a market in competitive equilibrium, which guarantees an optimal allocation of resources throughout the sensor network. This paper makes two contributions to the field of market-based optimization: First, we develop a market protocol to handle heterogeneous goods in a dynamic setting. Second, we develop arbitrage agents to improve the efficiency in the market in light of its dynamic nature.

  5. Influence of temperature and humidity on carbon based printed flexible sensors

    KAUST Repository

    Nag, Anindya

    2018-03-02

    This paper presents the response of two different types of novel printed sensors towards the change in temperature and humidity. The electrodes of all the sensors were based on carbon materials. Followed by the design and fabrication of the sensors, the responses of the sensors were analyzed for different temperature and humidity conditions in an incubator. These results provide a podium to enhance the alternation of the fabrication procedure of carbon-based printed sensors.

  6. Influence of temperature and humidity on carbon based printed flexible sensors

    KAUST Repository

    Nag, Anindya; Mukhopadhyay, Subhas; Kosel, Jü rgen

    2018-01-01

    This paper presents the response of two different types of novel printed sensors towards the change in temperature and humidity. The electrodes of all the sensors were based on carbon materials. Followed by the design and fabrication of the sensors, the responses of the sensors were analyzed for different temperature and humidity conditions in an incubator. These results provide a podium to enhance the alternation of the fabrication procedure of carbon-based printed sensors.

  7. Determination of HCl and VOC Emission from Thermal Degradation of PVC in the Absence and Presence of Copper, Copper(II Oxide and Copper(II Chloride

    Directory of Open Access Journals (Sweden)

    Ahamad J. Jafari

    2009-01-01

    Full Text Available Polyvinyl chloride (PVC has played a key role in the development of the plastic industry over the past 40 years. Thermal degradation of PVC leads to formation of many toxic pollutants such as HCl, aromatic and volatile organic carbon vapors. Thermal degradation of PVC and PVC in the present of copper, cupric oxide and copper(II chloride were investigated in this study using a laboratory scale electrical furnace. HCl and Cl- ion were analyzed by a Dionex ion chromatograph and VOCs compounds were analyzed using GC or GC-MS. The results showed that HCl plus Cl- ion and benzene formed about 99% and 80% respectively in the first step of thermal degradation under air atmosphere. The presence of cupric oxide increases the percentage of short chain hydrocarbons more than 184% and decreases the amount of the major aromatic hydrocarbon and HCl plus Cl- ion to 90% and 65% respectively. The total aromatic hydrocarbon emitted less than when atmosphere was air and difference was statistically significant (Pvalue<0.000

  8. Validation of Underwater Sensor Package Using Feature Based SLAM

    Directory of Open Access Journals (Sweden)

    Christopher Cain

    2016-03-01

    Full Text Available Robotic vehicles working in new, unexplored environments must be able to locate themselves in the environment while constructing a picture of the objects in the environment that could act as obstacles that would prevent the vehicles from completing their desired tasks. In enclosed environments, underwater range sensors based off of acoustics suffer performance issues due to reflections. Additionally, their relatively high cost make them less than ideal for usage on low cost vehicles designed to be used underwater. In this paper we propose a sensor package composed of a downward facing camera, which is used to perform feature tracking based visual odometry, and a custom vision-based two dimensional rangefinder that can be used on low cost underwater unmanned vehicles. In order to examine the performance of this sensor package in a SLAM framework, experimental tests are performed using an unmanned ground vehicle and two feature based SLAM algorithms, the extended Kalman filter based approach and the Rao-Blackwellized, particle filter based approach, to validate the sensor package.

  9. Validation of Underwater Sensor Package Using Feature Based SLAM

    Science.gov (United States)

    Cain, Christopher; Leonessa, Alexander

    2016-01-01

    Robotic vehicles working in new, unexplored environments must be able to locate themselves in the environment while constructing a picture of the objects in the environment that could act as obstacles that would prevent the vehicles from completing their desired tasks. In enclosed environments, underwater range sensors based off of acoustics suffer performance issues due to reflections. Additionally, their relatively high cost make them less than ideal for usage on low cost vehicles designed to be used underwater. In this paper we propose a sensor package composed of a downward facing camera, which is used to perform feature tracking based visual odometry, and a custom vision-based two dimensional rangefinder that can be used on low cost underwater unmanned vehicles. In order to examine the performance of this sensor package in a SLAM framework, experimental tests are performed using an unmanned ground vehicle and two feature based SLAM algorithms, the extended Kalman filter based approach and the Rao-Blackwellized, particle filter based approach, to validate the sensor package. PMID:26999142

  10. Estudo do efeito da incorporação de plastificante de fonte renovável em compostos de PVC

    Directory of Open Access Journals (Sweden)

    Derval dos Santos Rosa

    2013-01-01

    Full Text Available O acúmulo de resíduos poliméricos tem crescido nos últimos anos e os subsolos dos lixões já estão saturados com resíduos plásticos. Isso possivelmente se deve à elevada produção de resíduos sólidos de plásticos (cerca de 25 mil t/dia em 2008, segundo a Lei de Resíduos. Em vista disso, este trabalho apresenta uma análise comparativa do estudo do potencial de (biodegradação de compostos de PVC utilizando um plastificante de origem vegetal renovável (PFR com estrutura de éster de milho com massa molar 296,5 g.mol- 1 e dois plastificantes sintéticos, ftalato de dioctila (DOP e adipato de dioctila (DOA, buscando inovar na obtenção de um composto de PVC com um plastificante de fonte renovável. Os resultados de FTIR evidenciaram maior interação do PFR com a resina de PVC para o teor de 30 phr, e para o teor de 40 phr observou-se que os plastificantes DOP e PFR apresentaram os mesmos valores de variação da banda atática. Já os ensaios mecânicos reforçaram os resultados de FTIR com maior compatibilidade para as composições contendo PFR. Uma maior estabilidade térmica no composto de PVC foi observada por TGA para a amostra contendo 40 phr de DOA, o que foi confirmado por RMN, e para a amostra com PFR nos teores de 30 e 40 phr. Por fim, uma perda significativa de massa foi observada nos ensaios de resistência à extração por solvente para os compostos contendo DOA, sendo que a amostra com 30 phr mostrou menor valor de extração. A biodegradação em solo simulado mostrou maior perda de massa para as amostras plastificadas com DOA (40phr e PFR (40phr. Isso indica que é viável usar plastificante de fonte renovável nos compostos de PVC, devido à compatibilidade deste com esta resina.

  11. Flexible textile-based strain sensor induced by contacts

    International Nuclear Information System (INIS)

    Zhang, Hui

    2015-01-01

    In this paper, the contact effects are used as the key sensing element to develop flexible textile-structured strain sensors. The structures of the contact are analyzed theoretically and the contact resistances are investigated experimentally. The electromechanical properties of the textiles are investigated to find the key factors which determine the sensitivity, repeatability, and linearity of the sensor. The sensing mechanism is based on the change of contact resistance induced by the change of the configuration of the textiles. In order to improve the performance of the textile strain sensor, the contact resistance is designed based on the electromechanical properties of the fabric. It can be seen from the results that the performance of the sensor is largely affected by the structure of the contacts, which are determined by the morphology of fiber surface and the structures of the yarn and fabric. (paper)

  12. IBE-Lite: a lightweight identity-based cryptography for body sensor networks.

    Science.gov (United States)

    Tan, Chiu C; Wang, Haodong; Zhong, Sheng; Li, Qun

    2009-11-01

    A body sensor network (BSN) is a network of sensors deployed on a person's body for health care monitoring. Since the sensors collect personal medical data, security and privacy are important components in a BSN. In this paper, we developed IBE-Lite, a lightweight identity-based encryption suitable for sensors in a BSN. We present protocols based on IBE-Lite that balance security and privacy with accessibility and perform evaluation using experiments conducted on commercially available sensors.

  13. Bulk disk resonator based ultrasensitive mass sensor

    DEFF Research Database (Denmark)

    Cagliani, Alberto; Davis, Zachary James

    2009-01-01

    range. The sensor has been characterized in terms of sensitivity both for distributed mass detection, performing six consecutive depositions of e-beam evaporated Au, and localized mass detection, depositing approximately 7.5 pg of Pt/Ga/C three times consecutively with a Focused Ion Beam system......In the framework of developing an innovative label-free sensor for multiarrayed biodetection applications, we present a novel bulk resonator based mass sensor. The sensor is a polysilicon disk which shows a Q-factor of 6400 in air at 68.8 MHz, resulting in mass resolutions down in the femtogram....... The sensor has an extremely high distributed mass to frequency shift sensitivity of 60104 Hzcm2/¿g and shows a localized mass to frequency sensitivity up to 4405 Hz/pg with a localized mass resolution down to 15 fg. The device has been fabricated with a new microfabrication process that uses only two...

  14. Feedback-type giant magneto-impedance sensor based on longitudinal excitation

    International Nuclear Information System (INIS)

    Zhao Wen; Bu Xiongzhu; Yu Geliang; Xiang Chao

    2012-01-01

    In this paper, the characteristics of Fe-based amorphous ribbon based on the longitudinal excitation are investigated with assistance of the theory of the giant magneto-impedance (GMI) effect. A feedback-type GMI micro-magnetic sensor is designed with regard to the design of the sensing element, the excitation circuit, the conditional circuit and the feedback circuit. With the analysis of the dynamic and static characteristics of the feedback-type GMI sensor, it is concluded that the designed feedback-type GMI sensor has higher linearity, stability and dynamic characteristics than non-feedback-type GMI sensor in −2.5 to +2.5 Oe. - Highlights: ► A feedback-type GMI micro-magnetic sensor is designed. ► Excitation coil and feedback coil of the sensor is designed to be in one. ► The feedback-type sensor has higher linearity and stability than non-feedback type. ► The feedback-type sensor has better dynamic characteristics than non-feedback type.

  15. Radiation crosslinking of highly plasticized PVC

    Science.gov (United States)

    Mendizabal, E.; Cruz, L.; Jasso, C. F.; Burillo, G.; Dakin, V. I.

    1996-02-01

    To improve the physical properties of highly plasticized PVC, the polymer was crosslinked by gamma irradiation using a dose rate of 91 kGy/h. The effect of plasticizer type was studied by using three different plasticizers, 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB), di(2-ethyl hexyl) phthalate (DOP), and di(2-ethylhexyl terephthalate) (DOTP), and varying irradiation doses. Gel content was determined by soxhlet extraction, tensile measurements were made on a universal testing machine and the mechano-dynamic measurements were made in a dynamic rheometer. It was found that a considerable bonding of plasticizer molecules to macromolelcules takes place along with crosslinking, so that the use of the solvent extraction method for measuring the degree of crosslinking can give erroneous information. Radiation-chemical crosslinking yield ( Gc) and molecular weight of interjunctions chains ( Mc), were calculated for different systems studied. Addition of ethylene glycol dimethacrylate (EGDM) as a crosslinking coagent and dioctyl tin oxide (DOTO) as a stabilizer was also studied. Plasticizers extraction resistance was increased by irradiation treatment.

  16. Radiation crosslinking of highly plasticized PVC

    International Nuclear Information System (INIS)

    Mendizabal, E.; Cruz, L.; Jasso, C.F.; Burillo, G.; Dakin, V.I.

    1996-01-01

    To improve the physical properties of highly plasticized PVC, the polymer was crosslinked by gamma irradiation using a dose rate of 91 kGy/h. The effect of plasticizer type was studied by using three different plasticizers, 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB), di(2-ethyl hexyl) phthalate (DOP), and di(2-ethylhexyl terephthalate) (DOTP), and varying irradiation doses. Gel content was determined by soxhlet extraction, tensile measurements were made on a universal testing machine and the mechano-dynamic measurements were made in a dynamic rheometer. It was found that a considerable bonding of plasticizer molecules to macromolecules takes place along with crosslinking, so that the use of the solvent extraction method for measuring the degree of crosslinking can give erroneous information. Radiation-chemical crosslinking yield (G c ) and molecular weight of interjunctions chains (M c ), were calculated for different systems studied. Addition of ethylene glycol dimethyacrylate (EGDM) as a crosslinking coagent and dioctyl tin oxide (DOTO) as a stabilizer was also studied. Plasticizers extraction resistance was increased by irradiation treatment. (author)

  17. Analyzing the factors affecting network lifetime cluster-based wireless sensor network

    International Nuclear Information System (INIS)

    Malik, A.S.; Qureshi, A.

    2010-01-01

    Cluster-based wireless sensor networks enable the efficient utilization of the limited energy resources of the deployed sensor nodes and hence prolong the node as well as network lifetime. Low Energy Adaptive Clustering Hierarchy (Leach) is one of the most promising clustering protocol proposed for wireless sensor networks. This paper provides the energy utilization and lifetime analysis for cluster-based wireless sensor networks based upon LEACH protocol. Simulation results identify some important factors that induce unbalanced energy utilization between the sensor nodes and hence affect the network lifetime in these types of networks. These results highlight the need for a standardized, adaptive and distributed clustering technique that can increase the network lifetime by further balancing the energy utilization among sensor nodes. (author)

  18. Avaliação e caracterização de tubos fabricados com PVC reciclado

    Directory of Open Access Journals (Sweden)

    Luiz Carlos G. Pennafort Jr

    2013-01-01

    Full Text Available Neste trabalho foram caracterizados dois polímeros utilizados na fabricação de tubos de PVC, tendo como diferencial o uso de resina de policloreto de vinila virgem e reciclada. O uso da resina reciclada, derivada do reprocessamento de resíduos aterrados (sanitários ou industriais, foi avaliado com o objetivo de compará-la a produtos fabricados com resina virgem, os quais foram submetidos aos ensaios de Fluorescência de Raios X (FRX, Difração de Raios X (DRX e resistência à tração e alongamento. Os resultados demonstraram que houve alteração estatisticamente significativa, conforme ANOVA (5%, nas características mecânicas do produto final, tendo os tubos fabricados com PVC reciclado apresentado uma resistência mecânica menor que os fabricados com resina virgem, além da presença de metais pesados como Pb (chumbo e Cd (cádmio.

  19. THE GAS SENSORS BASED ON ZINC OXIDE (THE REVIEW)

    OpenAIRE

    Bugayova, M. E.; Koval, V. M.; Lashkarev, G. V.; Lazorenko, V. I.; Karpina, V. A.; Khranovskyy, V. D.

    2017-01-01

    The wide range of gas sensor application, in particular, in a mining industry for detection of outflow of gases, the control of gas emissions over an atmosphere at the industrial enterprises, in housing and communal services, in home appliances makes actual the review. As the systematized analysis of gas sensor based on ZnO has not being carried out — this work is of interest for development of chemical sensors based on zinc compound with high sensitivity, selectivity and stability. The resis...

  20. An Electronic-Nose Sensor Node Based on a Polymer-Coated Surface Acoustic Wave Array for Wireless Sensor Network Applications

    Science.gov (United States)

    Tang, Kea-Tiong; Li, Cheng-Han; Chiu, Shih-Wen

    2011-01-01

    This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW) sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K2 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT) was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC) was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN) applications. PMID:22163865

  1. An electronic-nose sensor node based on a polymer-coated surface acoustic wave array for wireless sensor network applications.

    Science.gov (United States)

    Tang, Kea-Tiong; Li, Cheng-Han; Chiu, Shih-Wen

    2011-01-01

    This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW) sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K(2) 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT) was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC) was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN) applications.

  2. An Electronic-Nose Sensor Node Based on a Polymer-Coated Surface Acoustic Wave Array for Wireless Sensor Network Applications

    Directory of Open Access Journals (Sweden)

    Kea-Tiong Tang

    2011-04-01

    Full Text Available This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K2 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN applications.

  3. Low Power and High Sensitivity MOSFET-Based Pressure Sensor

    International Nuclear Information System (INIS)

    Zhang Zhao-Hua; Ren Tian-Ling; Zhang Yan-Hong; Han Rui-Rui; Liu Li-Tian

    2012-01-01

    Based on the metal-oxide-semiconductor field effect transistor (MOSFET) stress sensitive phenomenon, a low power MOSFET pressure sensor is proposed. Compared with the traditional piezoresistive pressure sensor, the present pressure sensor displays high performances on sensitivity and power consumption. The sensitivity of the MOSFET sensor is raised by 87%, meanwhile the power consumption is decreased by 20%. (cross-disciplinary physics and related areas of science and technology)

  4. Phase separation and rubber phase dispersion in PVC/NBR blends

    OpenAIRE

    Passador, Fábio R.; Pessan, Luiz A.; Rodolfo Jr., Antonio

    2006-01-01

    Termoplásticos modificados com elastômeros têm despertado grande interesse de pesquisadores e de indústrias devido à atraente relação custo/benefício e a possibilidade de aumento significativo da tenacidade sob impacto de polímeros frágeis com a incorporação de uma fase borrachosa dispersa. Este artigo mostra a relação entre o estado de mistura e a dispersão da fase borrachosa em blendas de poli (cloreto de vinila) (PVC) com borracha nitrílica (NBR). O estado de mistura de blendas poliméricas...

  5. Wireless Sensor Network Based Subsurface Contaminant Plume Monitoring

    Science.gov (United States)

    2012-04-16

    Sensor Network (WSN) to monitor contaminant plume movement in naturally heterogeneous subsurface formations to advance the sensor networking based...time to assess the source and predict future plume behavior. This proof-of-concept research aimed at demonstrating the use of an intelligent Wireless

  6. Potentiometric Membrane Sensors for Levamisole Determination

    Directory of Open Access Journals (Sweden)

    Natalia Zubenya

    2016-11-01

    Full Text Available The ion pair (IP of levamisole with BiI4-(SbI4- for the levamisole-selective sensor with a PVC membrane containing - ions were developed. Thermal behavior of obtained IP was investigated by differential thermal analysis that would show the thermal stability and the character of the decomposition of the complex. The thermolysis of Lev+BiI4- IP undergoes three stages that fit a theoretical interpretation. the linearity ranges of levamisole sensors function are 7.9 ×10-6 – 1×10-1 (7.9 ×10-5 – 1×10-1 M. The Nernstian slope of                   50.6 – 53.4 mV pC−1 and detection limit of 5.0 × 10−5 – 1.5 × 10−4 M. The working range of pH is 2.8 – 6.0.     The efficiency of the use of electrodes for levamisole content control in pharmaceutical preparations was shown by direct potentiometry and potentiometric titration methods.

  7. Elements for successful sensor-based process control {Integrated Metrology}

    International Nuclear Information System (INIS)

    Butler, Stephanie Watts

    1998-01-01

    Current productivity needs have stimulated development of alternative metrology, control, and equipment maintenance methods. Specifically, sensor applications provide the opportunity to increase productivity, tighten control, reduce scrap, and improve maintenance schedules and procedures. Past experience indicates a complete integrated solution must be provided for sensor-based control to be used successfully in production. In this paper, Integrated Metrology is proposed as the term for an integrated solution that will result in a successful application of sensors for process control. This paper defines and explores the perceived four elements of successful sensor applications: business needs, integration, components, and form. Based upon analysis of existing successful commercially available controllers, the necessary business factors have been determined to be strong, measurable industry-wide business needs whose solution is profitable and feasible. This paper examines why the key aspect of integration is the decision making process. A detailed discussion is provided of the components of most importance to sensor based control: decision-making methods, the 3R's of sensors, and connectivity. A metric for one of the R's (resolution) is proposed to allow focus on this important aspect of measurement. A form for these integrated components which synergistically partitions various aspects of control at the equipment and MES levels to efficiently achieve desired benefits is recommended

  8. Elements for successful sensor-based process control {Integrated Metrology}

    Science.gov (United States)

    Butler, Stephanie Watts

    1998-11-01

    Current productivity needs have stimulated development of alternative metrology, control, and equipment maintenance methods. Specifically, sensor applications provide the opportunity to increase productivity, tighten control, reduce scrap, and improve maintenance schedules and procedures. Past experience indicates a complete integrated solution must be provided for sensor-based control to be used successfully in production. In this paper, Integrated Metrology is proposed as the term for an integrated solution that will result in a successful application of sensors for process control. This paper defines and explores the perceived four elements of successful sensor applications: business needs, integration, components, and form. Based upon analysis of existing successful commercially available controllers, the necessary business factors have been determined to be strong, measurable industry-wide business needs whose solution is profitable and feasible. This paper examines why the key aspect of integration is the decision making process. A detailed discussion is provided of the components of most importance to sensor based control: decision-making methods, the 3R's of sensors, and connectivity. A metric for one of the R's (resolution) is proposed to allow focus on this important aspect of measurement. A form for these integrated components which synergistically partitions various aspects of control at the equipment and MES levels to efficiently achieve desired benefits is recommended.

  9. SERS-based pesticide detection by using nanofinger sensors

    Science.gov (United States)

    Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong

    2015-01-01

    Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.

  10. Semiconductor device-based sensors for gas, chemical, and biomedical applications

    CERN Document Server

    Ren, Fan

    2011-01-01

    Sales of U.S. chemical sensors represent the largest segment of the multi-billion-dollar global sensor market, which includes instruments for chemical detection in gases and liquids, biosensors, and medical sensors. Although silicon-based devices have dominated the field, they are limited by their general inability to operate in harsh environments faced with factors such as high temperature and pressure. Exploring how and why these instruments have become a major player, Semiconductor Device-Based Sensors for Gas, Chemical, and Biomedical Applications presents the latest research, including or

  11. Evaluation of the Standard Ion Transfer Potentials for PVC Plasticized Membranes from Voltammetric Measurements

    Czech Academy of Sciences Publication Activity Database

    Langmaier, Jan; Stejskalová, Květoslava; Samec, Zdeněk

    2001-01-01

    Roč. 496, č. 1 (2001), s. 143-147 ISSN 0022-0728. [Symposium in Kyoto. Kyoto, 02.03.2000] R&D Projects: GA AV ČR IAA4040902 Institutional research plan: CEZ:AV0Z4040901 Keywords : ion voltammetry * PVC plasticized membrane * standard ion transfer potential Subject RIV: CG - Electrochemistry Impact factor: 1.960, year: 2001

  12. Image-based occupancy sensor

    Science.gov (United States)

    Polese, Luigi Gentile; Brackney, Larry

    2015-05-19

    An image-based occupancy sensor includes a motion detection module that receives and processes an image signal to generate a motion detection signal, a people detection module that receives the image signal and processes the image signal to generate a people detection signal, a face detection module that receives the image signal and processes the image signal to generate a face detection signal, and a sensor integration module that receives the motion detection signal from the motion detection module, receives the people detection signal from the people detection module, receives the face detection signal from the face detection module, and generates an occupancy signal using the motion detection signal, the people detection signal, and the face detection signal, with the occupancy signal indicating vacancy or occupancy, with an occupancy indication specifying that one or more people are detected within the monitored volume.

  13. Optical Slot-Waveguide Based Biochemical Sensors

    Directory of Open Access Journals (Sweden)

    Carlos Angulo Barrios

    2009-06-01

    Full Text Available Slot-waveguides allow light to be guided and strongly confined inside a nanometer-scale region of low refractive index. Thus stronger light-analyte interaction can be obtained as compared to that achievable by a conventional waveguide, in which the propagating beam is confined to the high-refractive-index core of the waveguide. In addition, slot-waveguides can be fabricated by employing CMOS compatible materials and technology, enabling miniaturization, integration with electronic, photonic and fluidic components in a chip, and mass production. These advantages have made the use of slot-waveguides for highly sensitive biochemical optical integrated sensors an emerging field. In this paper, recent achievements in slot-waveguide based biochemical sensing will be reviewed. These include slot-waveguide ring resonator based refractometric label-free biosensors, label-based optical sensing, and nano-opto-mechanical sensors.

  14. Palladium coated fibre Bragg grating based hydrogen sensor

    International Nuclear Information System (INIS)

    Kasinathan, M.; Sosamma, S.; Kishore, S.; Elumalai, V.; Krishnan, R.; Babu Rao, C.; Dash, Sitaram; Murali, N.; Jayakumar, T.

    2011-01-01

    Detection of steam generator leaks in fast nuclear reactors is carried out by monitoring hydrogen in argon cover-gas. Hydrogen released during sodium cleaning of fast reactor components is required to be monitored. Hydrogen sensors with good sensitivity, stability and response time are required for all the above applications. We report a new type of hydrogen sensor with a Fibre Bragg Grating (FBG) coated with palladium thin film which is used to detect the leak of hydrogen gas in the Steam Generator (SG) module of the Fast Breeder Reactor (FBR). If water leaks into sodium, it results in sodium-water reaction. In this reaction hydrogen and sodium hydroxide are formed. Due to the explosive risk of hydrogen system, hydrogen sensors are of great interest in this case. It is known that hydrogen forms an explosive mixture with air once its concentration exceeds beyond the explosion limit of four percent. The advantages of FBG based hydrogen sensor over the other hydrogen sensors are its inherent property of safety from sparking, immunity to ambient electromagnetic interference. The sensing mechanism in this device is based on mechanical strain that is induced in the palladium coating when it absorbs hydrogen. This process physically stretches the grating and causes the grating period and grating's refractive index, to change. The Bragg wavelength shift is directly proportional to the strain induced and can be directly related to the percentage of hydrogen exposure. The online monitoring of palladium thin film coating on FBG is carried out and recorded the wavelength change and strain induced on the FBG. A hydrogen sensor set up have been fabricated which consists of SS vessel of capacity 10 litres, provided with pressure gauge, Argon filling line with a valve, Hydrogen injection line with flange, a vent line with valve and Hydrogen sensor fixing point. The Palladium coated FBG based Hydrogen sensor is tested in this experimental facility in the exposure of hydrogen in

  15. POF based glucose sensor incorporating grating wavelength filters

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Aasmul, Søren; Bang, Ole

    2014-01-01

    AND RESEARCH IN POLYMER OPTICAL DEVICES; TRIPOD. Within the domain of TRIPOD, research is conducted on "Plastic Optical Fiber based Glucose Sensors Incorporating Grating Wavelength Filters". Research will be focused to optimized fiber tips for better coupling efficiency, reducing the response time of sensor...

  16. A smart sensor-based vision system: implementation and evaluation

    International Nuclear Information System (INIS)

    Elouardi, A; Bouaziz, S; Dupret, A; Lacassagne, L; Klein, J O; Reynaud, R

    2006-01-01

    One of the methods of solving the computational complexity of image-processing is to perform some low-level computations on the sensor focal plane. This paper presents a vision system based on a smart sensor. PARIS1 (Programmable Analog Retina-like Image Sensor1) is the first prototype used to evaluate the architecture of an on-chip vision system based on such a sensor coupled with a microcontroller. The smart sensor integrates a set of analog and digital computing units. This architecture paves the way for a more compact vision system and increases the performances reducing the data flow exchanges with a microprocessor in control. A system has been implemented as a proof-of-concept and has enabled us to evaluate the performance requirements for a possible integration of a microcontroller on the same chip. The used approach is compared with two architectures implementing CMOS active pixel sensors (APS) and interfaced to the same microcontroller. The comparison is related to image processing computation time, processing reliability, programmability, precision, bandwidth and subsequent stages of computations

  17. A smart sensor-based vision system: implementation and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Elouardi, A; Bouaziz, S; Dupret, A; Lacassagne, L; Klein, J O; Reynaud, R [Institute of Fundamental Electronics, Bat. 220, Paris XI University, 91405 Orsay (France)

    2006-04-21

    One of the methods of solving the computational complexity of image-processing is to perform some low-level computations on the sensor focal plane. This paper presents a vision system based on a smart sensor. PARIS1 (Programmable Analog Retina-like Image Sensor1) is the first prototype used to evaluate the architecture of an on-chip vision system based on such a sensor coupled with a microcontroller. The smart sensor integrates a set of analog and digital computing units. This architecture paves the way for a more compact vision system and increases the performances reducing the data flow exchanges with a microprocessor in control. A system has been implemented as a proof-of-concept and has enabled us to evaluate the performance requirements for a possible integration of a microcontroller on the same chip. The used approach is compared with two architectures implementing CMOS active pixel sensors (APS) and interfaced to the same microcontroller. The comparison is related to image processing computation time, processing reliability, programmability, precision, bandwidth and subsequent stages of computations.

  18. Preparation of anion exchange membrane using polyvinyl chloride (PVC) for alkaline water electrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Gab-Jin; Bong, Soo-Yeon; Ryu, Cheol-Hwi [Hoseo University, Asan (Korea, Republic of); Lim, Soo-Gon [Energy and Machinery Korea Co., Ltd., Changwon (Korea, Republic of); Choi, Ho-Sang [Kyungil University, Gyeongsan (Korea, Republic of)

    2015-09-15

    An anion exchange membrane was prepared by the chloromethylation and the amination of polyvinyl chloride (PVC), as the base polymer. The membrane properties of the prepared anion exchange membrane, including ionic conductivity, ion exchange capacity, and water content were measured. The ionic conductivity of the prepared anion exchange membrane was in the range of 0.098x10{sup -2} -7.0x10{sup -2}S cm{sup -1}. The ranges of ion exchange capacity and water content were 1.9-3.7meq./g-dry-membrane and 35.1-63.1%, respectively. The chemical stability of the prepared anion exchange membrane was tested by soaking in 30 wt% KOH solution to determine its availability as a separator in the alkaline water electrolysis. The ionic conductivity during the chemical stability test largely did not change.

  19. Wheel-Based Ice Sensors for Road Vehicles

    Science.gov (United States)

    Arndt, G. Dickey; Fink, Patrick W.; Ngo, Phong H.; Carl, James R.

    2011-01-01

    Wheel-based sensors for detection of ice on roads and approximate measurement of the thickness of the ice are under development. These sensors could be used to alert drivers to hazardous local icing conditions in real time. In addition, local ice-thickness measurements by these sensors could serve as guidance for the minimum amount of sand and salt required to be dispensed locally onto road surfaces to ensure safety, thereby helping road crews to utilize their total supplies of sand and salt more efficiently. Like some aircraft wing-surface ice sensors described in a number of previous NASA Tech Briefs articles, the wheelbased ice sensors are based, variously, on measurements of changes in capacitance and/or in radio-frequency impedance as affected by ice on surfaces. In the case of ice on road surfaces, the measurable changes in capacitance and/or impedance are attributable to differences among the electric permittivities of air, ice, water, concrete, and soil. In addition, a related phenomenon that can be useful for distinguishing between ice and water is a specific transition in the permittivity of ice at a temperature- dependent frequency. This feature also provides a continuous calibration of the sensor to allow for changing road conditions. Several configurations of wheel-based ice sensors are under consideration. For example, in a simple two-electrode capacitor configuration, one of the electrodes would be a circumferential electrode within a tire, and the ground would be used as the second electrode. Optionally, the steel belts that are already standard parts of many tires could be used as the circumferential electrodes. In another example (see figure), multiple electrodes would be embedded in rubber between the steel belt and the outer tire surface. These electrodes would be excited in alternating polarities at one or more suitable audio or radio frequencies to provide nearly continuous monitoring of the road surface under the tire. In still another

  20. Laboratory test of an APS-based sun sensor prototype

    Science.gov (United States)

    Rufino, Giancarlo; Perrotta, Alessandro; Grassi, Michele

    2017-11-01

    This paper deals with design and prototype development of an Active Pixel Sensor - based miniature sun sensor and a laboratory facility for its indoor test and calibration. The miniature sun sensor is described and the laboratory test facility is presented in detail. The major focus of the paper is on tests and calibration of the sensor. Two different calibration functions have been adopted. They are based, respectively, on a geometrical model, which has required least-squares optimisation of system physical parameters estimates, and on neural networks. Calibration results are presented for the above solutions, showing that accuracy in the order of 0.01° has been achieved. Neural calibration functions have attained better performance thanks to their intrinsic auto-adaptive structure.

  1. High performance liquid-level sensor based on mPOFBG for aircraft applications

    DEFF Research Database (Denmark)

    Marques, C. A. F.; Pospori, A.; Saez-Rodriguez, D.

    2015-01-01

    A high performance liquid-level sensor based on microstructured polymer optical fiber Bragg grating (mPOFBG) array sensors is reported in detail. The sensor sensitivity is found to be 98pm/cm of liquid, enhanced by more than a factor of 9 compared to a reported silica fiber-based sensor....

  2. Studies in cross-linking PVC footwear soling compounds using gamma-irradiation

    International Nuclear Information System (INIS)

    Bloom, L.I.

    1983-01-01

    Irradiation cross-linking of polymeric materials has been known for some time but it is only in recent years that it has been put to commercial advantage. Well known uses are the modification of PVC for high temperature applications such as under-bonnet wiring, stove wiring, post office telecommunication wire and shrink tubing. In South Africa interest in developing commercial applications for cross-linkable polymeric materials was initially stimulated through the work of the Atomic Energy Board at Pelindaba in late 1971 using a cobalt - 60 gamma radiation unit

  3. Microcontroller based instrumentation for heater control circuit of tin oxide based hydrogen sensor

    International Nuclear Information System (INIS)

    Premalatha, S.; Krithika, P.; Gunasekaran, G.; Ramakrishnan, R.; Ramanarayanan, R.R.; Prabhu, E.; Jayaraman, V.; Parthasarathy, R.

    2015-01-01

    A thin film sensor based on tin oxide developed in IGCAR is used to monitor very low levels of hydrogen (concentration ranging from 2 ppm to 80 ppm). The heater and the sensor patterns are integrated on a miniature alumina substrate and necessary electrical leads are taken out. For proper functioning of the sensor, the heater has to be maintained at a constant temperature of 350°C. The sensor output (voltage signal) varies with H 2 concentration. In fast breeder reactors, liquid sodium is used as coolant. The sensor is used to detect water/steam leak in secondary sodium circuit. During the start up of the reactor, steam leak into sodium circuit generates hydrogen gas as a product that doesn't dissolve in sodium, but escapes to the surge tank containing argon i.e. in cover gas plenum of sodium circuit. On-line monitoring of hydrogen in cover gas is done to detect an event of water/steam leakage. The focus of this project is on the instrumentation pertaining to the temperature control for the sensor heater. The tin oxide based hydrogen sensor is embedded in a substrate which consists of a platinum heater, essentially a resistor. There is no provision of embedding a temperature sensor on the heater surface due to the physical constraints, without which maintaining a constant heater temperature is a complex task

  4. Nanomaterials-based electrochemical sensors for nitric oxide

    International Nuclear Information System (INIS)

    Dang, Xueping; Hu, Hui; Wang, Shengfu; Hu, Shengshui

    2015-01-01

    Electrochemical sensing has been demonstrated to represent an efficient way to quantify nitric oxide (NO) in challenging physiological environments. A sensing interface based on nanomaterials opens up new opportunities and broader prospects for electrochemical NO sensors. This review (with 141 refs.) gives a general view of recent advances in the development of electrochemical sensors based on nanomaterials. It is subdivided into sections on (i) carbon derived nanomaterials (such as carbon nanotubes, graphenes, fullerenes), (ii) metal nanoparticles (including gold, platinum and other metallic nanoparticles); (iii) semiconductor metal oxide nanomaterials (including the oxides of titanium, aluminum, iron, and ruthenium); and finally (iv) nanocomposites (such as those formed from carbon nanomaterials with nanoparticles of gold, platinum, NiO or TiO 2 ). The various strategies are discussed, and the advances of using nanomaterials and the trends in NO sensor technology are outlooked in the final section. (author)

  5. MEMS-based sensors for post-earthquake damage assessment

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, M; Zonta, D; Trapani, D [DIMS, University of Trento, Via Mesiano 77, 38123, Trento (Italy); Athanasopoulos, N; Garetsos, A; Stratakos, Y E [Advanced Microwave Systems Ltd, 2, 25th Martiou Street, 17778 Athens (Greece); Amditis, A J; Bimpas, M [ICCS, National Technical University of Athens, 9 Iroon Polytechniou Street, 15773 Zografou (Greece); Ulieru, D, E-mail: daniele.zonta@unitn.it [SITEX 45 SRL, 114 Ghica Tei Blvd, 72235 Bucharest (Romania)

    2011-07-19

    The evaluation of seismic damage is today almost exclusively based on visual inspection, as building owners are generally reluctant to install permanent sensing systems, due to their high installation, management and maintenance costs. To overcome this limitation, the EU-funded MEMSCON project aims to produce small size sensing nodes for measurement of strain and acceleration, integrating Micro-Electro-Mechanical Systems (MEMS) based sensors and Radio Frequency Identification (RFID) tags in a single package that will be attached to reinforced concrete buildings and will transmit data using a wireless interface. During the first phase of the project completed so far, sensor prototypes were produced by assembling preexisting components. This paper outlines the device operating principles, production scheme and operation at both unit and network levels. It also reports on validation campaigns conducted in the laboratory to assess system performance. Accelerometer sensors were tested on a reduced scale metal frame mounted on a shaking table, while strain sensors were embedded in both reduced and full-scale reinforced concrete specimens undergoing increasing deformation cycles up to extensive damage and collapse. The performance of the sensors developed for the project and their applicability to long-term seismic monitoring are discussed.

  6. An all-solid-state screen-printed carbon paste reference electrode based on poly(3,4-ethylenedioxythiophene) as solid contact transducer

    International Nuclear Information System (INIS)

    Xu, Hui; Pan, Yiwen; Chen, Ying; Ye, Ying; Wang, You; Li, Guang

    2012-01-01

    The paper presents the design of an all-solid-state portable reference electrode based on a screen-printed carbon paste electrode suitable for rapid human serum testing. The electrode was covered by electropolymerized poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrenesulfonate) (PSS) as an internal solid contact layer and polyvinyl chloride (PVC) membrane containing lipophilic anion and cation additives. The electrochemical properties of PEDOT(PSS) and PEDOT(PSS)/PVC film on a carbon paste electrode were studied by electrochemical impedance spectroscopy and cyclic voltammetry methods. The reference electrode exhibited good potential stability (for H + , Na + , K + , Ca 2+ , Cl − and CO 2− 3 /HCO − 3 ), good reproducibility and long-term stability. The structure is applied as reference electrodes in human serum pH analysis with pH ion selective planar electrodes, forming a serum pH sensor. The response time of such a pH sensor was 15 s and the sensitivity was −52.2 ± 1.0 mV per decade. Other properties, such as repeatability, reproducibility and stability, were also evaluated. Clinical trials were carried out and compared with the results obtained from the routine hospital electrolyte analyzer, which demonstrated that their analytical performance was closely matched. (paper)

  7. Triple-helix molecular switch-based aptasensors and DNA sensors.

    Science.gov (United States)

    Bagheri, Elnaz; Abnous, Khalil; Alibolandi, Mona; Ramezani, Mohammad; Taghdisi, Seyed Mohammad

    2018-07-15

    Utilization of traditional analytical techniques is limited because they are generally time-consuming and require high consumption of reagents, complicated sample preparation and expensive equipment. Therefore, it is of great interest to achieve sensitive, rapid and simple detection methods. It is believed that nucleic acids assays, especially aptamers, are very important in modern life sciences for target detection and biological analysis. Aptamers and DNA-based sensors have been widely used for the design of various sensors owing to their unique features. In recent years, triple-helix molecular switch (THMS)-based aptasensors and DNA sensors have been broadly utilized for the detection and analysis of different targets. The THMS relies on the formation of DNA triplex via Watson-Crick and Hoogsteen base pairings under optimal conditions. This review focuses on recent progresses in the development and applications of electrochemical, colorimetric, fluorescence and SERS aptasensors and DNA sensors, which are based on THMS. Also, the advantages and drawbacks of these methods are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Fleet Protection Using a Small UAV Based IR Sensor

    National Research Council Canada - National Science Library

    Buss, James R; Ax, Jr, George R

    2005-01-01

    A study was performed to define candidate electro-optical and infrared (EO/IR) sensor configurations and assess their potential utility as small UAV-based sensors surveilling a perimeter around surface fleet assets...

  9. YSZ-based sensor using Cr-Fe-based spinel-oxide electrodes for selective detection of CO.

    Science.gov (United States)

    Anggraini, Sri Ayu; Fujio, Yuki; Ikeda, Hiroshi; Miura, Norio

    2017-08-22

    A selective carbon monoxide (CO) sensor was developed by the use of both of CuCrFeO 4 and CoCrFeO 4 as the sensing electrode (SE) for yttria-stabilized zirconia (YSZ)-based potentiometric sensor. The sensing-characteristic examinations of the YSZ-based sensors using each of spinel oxides as the single-SE sensor showed that CuCrFeO 4 -SE had the ability to detect CO, hydrocarbons and NO x gases, while CoCrFeO 4 -SE was sensitive to hydrocarbons and NO x gases. Thus, when both SEs were paired as a combined-SEs sensor, the resulting sensor could generate a selective response to CO at 450 °C under humid conditions. The sensor was also capable of detecting CO in the concentration range of 20-700 ppm. Its sensing mechanism that was examined via polarization-curve measurements was confirmed to be based on mixed-potential model. The CO response generated by the combined-SEs sensor was unaffected by the change of water vapor concentration in the range of 1.3-11.5 vol% H 2 O. Additionally, the sensing performance was stable during 13 days tested. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Pyrolysis studies of PP/PE/PS/PVC/HIPS-Br plastics mixed with PET and dehalogenation (Br, Cl) of the liquid products

    Energy Technology Data Exchange (ETDEWEB)

    Bhaskar, Thallada; Kaneko, Jun; Muto, Akinori; Sakata, Yusaku [Department of Applied Chemistry, Faculty of Engineering, Okayama University, 3-1-1 Tsushima Naka, 700-8530 Okayama (Japan); Jakab, Emma [Research Laboratory of Materials and Environmental Chemistry, Chemical Research Center, Hungarian Academy of Sciences, P.O. Box 17, H-1525 Budapest (Hungary); Matsui, Toshiki [Toda Kogyo Co. Ltd., Hiroshima 739-0652 (Japan); Uddin, Md. Azhar [Process Safety and Environment Protection Group, School of Engineering, The University of Newcastle, Callaghan, NSW 2308 (Australia)

    2004-08-01

    Pyrolysis of polypropylene (PP)/polyethylene (PE)/polystyrene (PS)/poly(vinyl chloride) (PVC)/high impact polystyrene with brominated flame retardant (HIPS-Br) plastics mixed with poly(ethylene terephthalate) (PET) was performed at 430C under atmospheric pressure using a semi-batch operation. The presence of PET in the pyrolysis mixture of PP/PE/PS/PVC/HIPS-Br affected significantly the formation of decomposition products and the decomposition behavior of the plastic mixture. We observed the following effects of PET on the pyrolysis of PP/PE/PS/PVC/HIPS-Br mixed plastics: (1) the yield of liquid product decreased and the formation of gaseous products increased; (2) a waxy residue was formed in addition to the solid carbon residue; (3) the formation of SbBr{sub 3} was not detected in liquid products; (4) the yield of chlorinated branched alkanes increased as well as vinyl bromide and ethyl bromide were formed. The use of calcium carbonate carbon composite (Ca-C) completely removed the chlorine and bromine content from the liquid products during PP/PE/PS/PVC/HIPS-Br pyrolysis, however in the presence of PET, the catalytic experiment (Ca-C, 8g) yielded liquid products containing 310ppm of Br and 20ppm of Cl. In addition, the Ca-C increased the yield of liquid products about 3-6wt.%, as well as enhanced the gaseous product evolution and decreased the yield of residue. The halogen free liquid hydrocarbons can be used as a feedstock in a refinery or as a fuel.

  11. Standards-Based Wireless Sensor Networking Protocols for Spaceflight Applications

    Science.gov (United States)

    Wagner, Raymond S.

    2010-01-01

    Wireless sensor networks (WSNs) have the capacity to revolutionize data gathering in both spaceflight and terrestrial applications. WSNs provide a huge advantage over traditional, wired instrumentation since they do not require wiring trunks to connect sensors to a central hub. This allows for easy sensor installation in hard to reach locations, easy expansion of the number of sensors or sensing modalities, and reduction in both system cost and weight. While this technology offers unprecedented flexibility and adaptability, implementing it in practice is not without its difficulties. Recent advances in standards-based WSN protocols for industrial control applications have come a long way to solving many of the challenges facing practical WSN deployments. In this paper, we will overview two of the more promising candidates - WirelessHART from the HART Communication Foundation and ISA100.11a from the International Society of Automation - and present the architecture for a new standards-based sensor node for networking and applications research.

  12. CMOS image sensor-based immunodetection by refractive-index change.

    Science.gov (United States)

    Devadhasan, Jasmine P; Kim, Sanghyo

    2012-01-01

    A complementary metal oxide semiconductor (CMOS) image sensor is an intriguing technology for the development of a novel biosensor. Indeed, the CMOS image sensor mechanism concerning the detection of the antigen-antibody (Ag-Ab) interaction at the nanoscale has been ambiguous so far. To understand the mechanism, more extensive research has been necessary to achieve point-of-care diagnostic devices. This research has demonstrated a CMOS image sensor-based analysis of cardiovascular disease markers, such as C-reactive protein (CRP) and troponin I, Ag-Ab interactions on indium nanoparticle (InNP) substrates by simple photon count variation. The developed sensor is feasible to detect proteins even at a fg/mL concentration under ordinary room light. Possible mechanisms, such as dielectric constant and refractive-index changes, have been studied and proposed. A dramatic change in the refractive index after protein adsorption on an InNP substrate was observed to be a predominant factor involved in CMOS image sensor-based immunoassay.

  13. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design.

    Science.gov (United States)

    Farhadi, Khalil; Bahram, Morteza; Shokatynia, Donya; Salehiyan, Floria

    2008-07-15

    Central composite design (CCD) and response surface methodology (RSM) were developed as experimental strategies for modeling and optimization of the influence of some variables on the performance of a new PVC membrane triiodide ion-selective electrode. This triiodide sensor is based on triiodide-clozapine ion-pair complexation. PVC, plasticizers, ion-pair amounts and pH were investigated as four variables to build a model to achieve the best Nernstian slope (59.9 mV) as response. The electrode is prepared by incorporating the ion-exchanger in PVC matrix plasticized with 2-nitrophenyl octal ether, which is directly coated on the surface of a graphite electrode. The influence of foreign ions on the electrode performance was also investigated. The optimized membranes demonstrate Nernstian response for triiodide ions over a wide linear range from 5.0 x 10(-6) to 1.0 x 10(-2)mol L(-1) with a limit of detection 2.0 x 10(-6) mol L(-1) at 25 degrees C. The electrodes could be used over a wide pH range 4-8, and have the advantages of easy to prepare, good selectivity and fast response time, long lifetime (over 3 months) and small interferences from hydrogen ion. The proposed electrode was successfully used as indicator electrode in potentiometric titration of triiodide ions and ascorbic acid.

  14. Molecular analysis of long-term biofilm formation on PVC and cast iron surfaces in drinking water distribution system.

    Science.gov (United States)

    Liu, Ruyin; Zhu, Junge; Yu, Zhisheng; Joshi, DevRaj; Zhang, Hongxun; Lin, Wenfang; Yang, Min

    2014-04-01

    To understand the impacts of different plumbing materials on long-term biofilm formation in water supply system, we analyzed microbial community compositions in the bulk water and biofilms on faucets with two different materials-polyvinyl chloride (PVC) and cast iron, which have been frequently used for more than10 years. Pyrosequencing was employed to describe both bacterial and eukaryotic microbial compositions. Bacterial communities in the bulk water and biofilm samples were significantly different from each other. Specific bacterial populations colonized on the surface of different materials. Hyphomicrobia and corrosion associated bacteria, such as Acidithiobacillus spp., Aquabacterium spp., Limnobacter thiooxidans, and Thiocapsa spp., were the most dominant bacteria identified in the PVC and cast iron biofilms, respectively, suggesting that bacterial colonization on the material surfaces was selective. Mycobacteria and Legionella spp. were common potential pathogenic bacteria occurred in the biofilm samples, but their abundance was different in the two biofilm bacterial communities. In contrast, the biofilm samples showed more similar eukaryotic communities than the bulk water. Notably, potential pathogenic fungi, i.e., Aspergillus spp. and Candida parapsilosis, occurred in similar abundance in both biofilms. These results indicated that microbial community, especially bacterial composition was remarkably affected by the different pipe materials (PVC and cast iron). Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  15. Novel ammonia sensor based on polyaniline/polylactic acid composite films

    International Nuclear Information System (INIS)

    Sotirov, S; Bodurov, I; Marudova, M

    2017-01-01

    We propose a new type of ammonia sensor based on composite film between polyaniline (emeraldine base) dissolved in dimethylformamide, and poly(DL-lactic) acid dissolved in chloroform. The two solutions were mixed in weight ratio of the components 1:1 and cast on Al 2 O 3 substrate, on which silver electrodes were deposited previously. The active layer structure and morphology were examined by atomic force microscopy. The sensor resistance at constant humidity and different ammonia concentrations was measured. It was found that an increase in the ammonia concentration leads to resistance increase. This result is explained in the terms of ionic interactions between the polyaniline and the ammonia, which change the permittivity of the sensor active media. A response between 2% and 590% was shown depending on the ammonia concentration. The sensor is reversible and possesses response time of typically 100 s. Based on the changes of the sensor resistance, ammonia concentration from 10 ppm to 1000 ppm could be detected. (paper)

  16. Novel ammonia sensor based on polyaniline/polylactic acid composite films

    Science.gov (United States)

    Sotirov, S.; Bodurov, I.; Marudova, M.

    2017-01-01

    We propose a new type of ammonia sensor based on composite film between polyaniline (emeraldine base) dissolved in dimethylformamide, and poly(DL-lactic) acid dissolved in chloroform. The two solutions were mixed in weight ratio of the components 1:1 and cast on Al2O3 substrate, on which silver electrodes were deposited previously. The active layer structure and morphology were examined by atomic force microscopy. The sensor resistance at constant humidity and different ammonia concentrations was measured. It was found that an increase in the ammonia concentration leads to resistance increase. This result is explained in the terms of ionic interactions between the polyaniline and the ammonia, which change the permittivity of the sensor active media. A response between 2% and 590% was shown depending on the ammonia concentration. The sensor is reversible and possesses response time of typically 100 s. Based on the changes of the sensor resistance, ammonia concentration from 10 ppm to 1000 ppm could be detected.

  17. Automated mode shape estimation in agent-based wireless sensor networks

    Science.gov (United States)

    Zimmerman, Andrew T.; Lynch, Jerome P.

    2010-04-01

    Recent advances in wireless sensing technology have made it possible to deploy dense networks of sensing transducers within large structural systems. Because these networks leverage the embedded computing power and agent-based abilities integral to many wireless sensing devices, it is possible to analyze sensor data autonomously and in-network. In this study, market-based techniques are used to autonomously estimate mode shapes within a network of agent-based wireless sensors. Specifically, recent work in both decentralized Frequency Domain Decomposition and market-based resource allocation is leveraged to create a mode shape estimation algorithm derived from free-market principles. This algorithm allows an agent-based wireless sensor network to autonomously shift emphasis between improving mode shape accuracy and limiting the consumption of certain scarce network resources: processing time, storage capacity, and power consumption. The developed algorithm is validated by successfully estimating mode shapes using a network of wireless sensor prototypes deployed on the mezzanine balcony of Hill Auditorium, located on the University of Michigan campus.

  18. Highly sensitive wearable strain sensor based on silver nanowires and nanoparticles

    Science.gov (United States)

    Shengbo, Sang; Lihua, Liu; Aoqun, Jian; Qianqian, Duan; Jianlong, Ji; Qiang, Zhang; Wendong, Zhang

    2018-06-01

    Here, we propose a highly sensitive and stretchable strain sensor based on silver nanoparticles and nanowires (Ag NPs and NWs), advancing the rapid development of electronic skin. To improve the sensitivity of strain sensors based on silver nanowires (Ag NWs), Ag NPs and NWs were added to polydimethylsiloxane (PDMS) as an aid filler. Silver nanoparticles (Ag NPs) increase the conductive paths for electrons, leading to the low resistance of the resulting sensor (14.9 Ω). The strain sensor based on Ag NPs and NWs showed strong piezoresistivity with a tunable gauge factor (GF) at 3766, and a change in resistance as the strain linearly increased from 0% to 28.1%. The high GF demonstrates the irreplaceable role of Ag NPs in the sensor. Moreover, the applicability of our high-performance strain sensor has been demonstrated by its ability to sense movements caused by human talking, finger bending, wrist raising and walking.

  19. PALLADIUM DOPED TIN OXIDE BASED HYDROGEN GAS SENSORS FOR SAFETY APPLICATIONS

    International Nuclear Information System (INIS)

    Kasthurirengan, S.; Behera, Upendra; Nadig, D. S.

    2010-01-01

    Hydrogen is considered to be a hazardous gas since it forms a flammable mixture between 4 to 75% by volume in air. Hence, the safety aspects of handling hydrogen are quite important. For this, ideally, highly selective, fast response, small size, hydrogen sensors are needed. Although sensors based on different technologies may be used, thin-film sensors based on palladium (Pd) are preferred due to their compactness and fast response. They detect hydrogen by monitoring the changes to the electrical, mechanical or optical properties of the films. We report the development of Pd-doped tin-oxide based gas sensors prepared on thin ceramic substrates with screen printed platinum (Pt) contacts and integrated nicrome wire heaters. The sensors are tested for their performances using hydrogen-nitrogen gas mixtures to a maximum of 4%H 2 in N 2 . The sensors detect hydrogen and their response times are less than a few seconds. Also, the sensor performance is not altered by the presence of helium in the test gas mixtures. By the above desired performance characteristics, field trials of these sensors have been undertaken. The paper presents the details of the sensor fabrication, electronic circuits, experimental setup for evaluation and the test results.

  20. Carbon nanotube based pressure sensor for flexible electronics

    International Nuclear Information System (INIS)

    So, Hye-Mi; Sim, Jin Woo; Kwon, Jinhyeong; Yun, Jongju; Baik, Seunghyun; Chang, Won Seok

    2013-01-01

    Highlights: • The electromechanical change of vertically aligned carbon nanotubes. • Fabrication of CNT field-effect transistor on flexible substrate. • CNT based FET integrated active pressure sensor. • The integrated device yields an increase in the source-drain current under pressure. - Abstract: A pressure sensor was developed based on an arrangement of vertically aligned carbon nanotubes (VACNTs) supported by a polydimethylsiloxane (PDMS) matrix. The VACNTs embedded in the PDMS matrix were structurally flexible and provided repeated sensing operation due to the high elasticities of both the polymer and the carbon nanotubes (CNTs). The conductance increased in the presence of a loading pressure, which compressed the material and induced contact between neighboring CNTs, thereby producing a dense current path and better CNT/metal contacts. To achieve flexible functional electronics, VACNTs based pressure sensor was integrated with field-effect transistor, which is fabricated using sprayed semiconducting carbon nanotubes on plastic substrate

  1. Carbon nanotube based pressure sensor for flexible electronics

    Energy Technology Data Exchange (ETDEWEB)

    So, Hye-Mi [Department of Nano Mechanics, Nanomechanical Systems Research Division, Korea Institute of Machinery and Materials, Daejeon 305-343 (Korea, Republic of); Sim, Jin Woo [Advanced Nano Technology Ltd., Seoul 132-710 (Korea, Republic of); Kwon, Jinhyeong [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of); Yun, Jongju; Baik, Seunghyun [SKKU Advanced Institute of Nanotechnology (SAINT), Department of Energy Science and School of Mechanical Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 440-746 (Korea, Republic of); Chang, Won Seok, E-mail: paul@kimm.re.kr [Department of Nano Mechanics, Nanomechanical Systems Research Division, Korea Institute of Machinery and Materials, Daejeon 305-343 (Korea, Republic of)

    2013-12-15

    Highlights: • The electromechanical change of vertically aligned carbon nanotubes. • Fabrication of CNT field-effect transistor on flexible substrate. • CNT based FET integrated active pressure sensor. • The integrated device yields an increase in the source-drain current under pressure. - Abstract: A pressure sensor was developed based on an arrangement of vertically aligned carbon nanotubes (VACNTs) supported by a polydimethylsiloxane (PDMS) matrix. The VACNTs embedded in the PDMS matrix were structurally flexible and provided repeated sensing operation due to the high elasticities of both the polymer and the carbon nanotubes (CNTs). The conductance increased in the presence of a loading pressure, which compressed the material and induced contact between neighboring CNTs, thereby producing a dense current path and better CNT/metal contacts. To achieve flexible functional electronics, VACNTs based pressure sensor was integrated with field-effect transistor, which is fabricated using sprayed semiconducting carbon nanotubes on plastic substrate.

  2. Migration of plasticisers from PVC and other polymers

    DEFF Research Database (Denmark)

    Lundsgaard, Rasmus

    ). In this work it is shown how diffusion coefficients can be obtained by regression of experimental migration data plotted as the square root of time. This was done from plasticiser migration data of GRINDSTEDr SOFT-N-SAFE, GRINDSTEDr ACETEM 95 CO (Acetem) and Epoxidised Soybean Oil (ESBO) migrating from......The main purpose of this thesis is to investigate, from a modeling point of view, the migration of GRINDSTEDr SOFT-N-SAFE (SNS) and other plasticisers from polyvinyl chloride (PVC) and polyolefin food package materials and into foodstuff (specifically the four food simulants set by EU legislation...... coefficients at 20◦C, except at higher temperatures. Using the finite element mesh method in Matlab and COMSOL environments the migration was modeled with a diffusion coefficient able to change with local plasticiser concentration. Three different models for this plasticiser concentration dependence...

  3. Highly sensitive strain sensors based on fragmentized carbon nanotube/polydimethylsiloxane composites.

    Science.gov (United States)

    Gao, Yang; Fang, Xiaoliang; Tan, Jianping; Lu, Ting; Pan, Likun; Xuan, Fuzhen

    2018-06-08

    Wearable strain sensors based on nanomaterial/elastomer composites have potential applications in flexible electronic skin, human motion detection, human-machine interfaces, etc. In this research, a type of high performance strain sensors has been developed using fragmentized carbon nanotube/polydimethylsiloxane (CNT/PDMS) composites. The CNT/PDMS composites were ground into fragments, and a liquid-induced densification method was used to fabricate the strain sensors. The strain sensors showed high sensitivity with gauge factors (GFs) larger than 200 and a broad strain detection range up to 80%, much higher than those strain sensors based on unfragmentized CNT/PDMS composites (GF sensors is ascribed to the sliding of individual fragmentized-CNT/PDMS-composite particles during mechanical deformation, which causes significant resistance change in the strain sensors. The strain sensors can differentiate mechanical stimuli and monitor various human body motions, such as bending of the fingers, human breathing, and blood pulsing.

  4. Hydrogel-based piezoresistive sensor for the detection of ethanol

    Directory of Open Access Journals (Sweden)

    J. Erfkamp

    2018-04-01

    Full Text Available This article describes a low-cost sensor for the detection of ethanol in alcoholic beverages, which combines alcohol-sensitive hydrogels based on acrylamide and bisacrylamide and piezoresistive sensors. For reproducible measurements, the reversible swelling and deswelling of the hydrogel were shown via microscopy. The response time of the sensor depends on the swelling kinetics of the hydrogel. The selectivity of the hydrogel was tested in different alcohols. In order to understand the influence of monomer and crosslinker content on the swelling degree and on the sensitivity of the hydrogels, gels with variable concentrations of acrylamide and bisacrylamide were synthesized and characterized in different aqueous solutions with alcohol contents. The first measurements of such hydrogel-based piezoresistive ethanol sensors demonstrated a high sensitivity and a short response time over several measuring cycles.

  5. PVC Based Membrane of Ti(IV Iodovanadate for Pb(II Determination

    Directory of Open Access Journals (Sweden)

    Mu. Naushad

    2008-08-01

    Full Text Available Ti(IV iodovanadate has been synthesized by mixing a mixture of aqueous solutions of 0.1 M sodium vanadate and 0.1 M potassium iodate with 0.1 M solution of Ti(IV chloride at pH 1.0. Distribution coefficients (Kd of various metal ions were determined on the column of Ti(IV iodovanadate which showed the selectivity of Pb(II ions by this cation exchange material. So Ti(IV iodovanadate has been used as an electoactive material for the construction of Pb(II selective electrode. The main purpose of this study is to develop an inexpensive, simple and reliable ion-selective electrode for Pb(II determination. The sensor exhibit Nernstian response for Pb(II ions over a wide concentration range of 1 x 10-7 M to 1 x 10-1 M with a slope of 30±0.4 mV per decade of activity. The electrode is suitable for use in aqueous solution in a pH range of 2-7.2 with a response time of 10 second. The membrane electrode can be used at least for 4 months without any divergence in potential. The selectivity coefficients were determined by the mixed solution method and revealed that the electrode was selective for Pb(II ions in the presence of interfering cations. The sensor could be used as an indicator electrode in the potentiometric titration of Pb(II ions with EDTA. The practical applicability of the proposed sensor has been reported for Pb(II determination in a standard rock sample and water sample. The results are found to be in good agreement with those obtained by using conventional methods.

  6. Toward CMOS image sensor based glucose monitoring.

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Kim, Sanghyo

    2012-09-07

    Complementary metal oxide semiconductor (CMOS) image sensor is a powerful tool for biosensing applications. In this present study, CMOS image sensor has been exploited for detecting glucose levels by simple photon count variation with high sensitivity. Various concentrations of glucose (100 mg dL(-1) to 1000 mg dL(-1)) were added onto a simple poly-dimethylsiloxane (PDMS) chip and the oxidation of glucose was catalyzed with the aid of an enzymatic reaction. Oxidized glucose produces a brown color with the help of chromogen during enzymatic reaction and the color density varies with the glucose concentration. Photons pass through the PDMS chip with varying color density and hit the sensor surface. Photon count was recognized by CMOS image sensor depending on the color density with respect to the glucose concentration and it was converted into digital form. By correlating the obtained digital results with glucose concentration it is possible to measure a wide range of blood glucose levels with great linearity based on CMOS image sensor and therefore this technique will promote a convenient point-of-care diagnosis.

  7. Towards Scalable Strain Gauge-Based Joint Torque Sensors

    Science.gov (United States)

    D’Imperio, Mariapaola; Cannella, Ferdinando; Caldwell, Darwin G.; Cuschieri, Alfred

    2017-01-01

    During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS), the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot-MiniHyQ. This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR). PMID:28820446

  8. ANALYTICAL MODELING OF INNOVATIVE SENSOR PLACEMENT STRATEGY FOR CORONA-BASED WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    HASSAN H. EKAL

    2017-09-01

    Full Text Available Wireless Sensor Networks (WSNs applications are increasing rapidly, thanks to their broad potential in ecological monitoring, biomedical health monitoring, data gathering and many others. Imbalance energy of sensors causes significant reduction in the lifetime of the network. In many-to-one communication (corona WSNs, sensor nodes located nearby the data collector (sink forward data sensed data received from other nodes, hence, having heavier workloads. These nodes consume more energy than the others, leading to quicker energy depletion.Consequently, this results in energy hole problem, where the network becomes separate islands, which affect the lifetime of the network negatively. When this situation occurs, the sensed data will not be forwarded to the intended sink; accordingly, the network will not be able to completely fulfil its required tasks. In this paper, an effective sensors placement strategy is proposed to avoid or alleviate energy hole problem in such type of WSNs. The proposed strategy aims to improve, scale, and balance the energy consumption among sensor nodes and to maximize the network lifetime, by sustaining the network coverage and connectivity. To achieve this aim, the number of sensors should be optimized to create sub-balanced coronas in the sense of energy consumption, while satisfying the network coverage and connectivity requirements. The theoretical design and modelling of the proposed sensors placement strategy promise a considerable improvement in the lifetime of corona-based networks. The Experimental evaluation results have shown that the proposed sensors placement strategy is capable to increase the network lifetime considerably compared to conventional uniform strategy.

  9. Processing of nanocomposites EVA/PVC/MMT in twin-screw extruder; Processamento de nanocompositos EVA/PVC/MMT em extrusora dupla rosca

    Energy Technology Data Exchange (ETDEWEB)

    Gehlen, A.; Barbutti Filho, W.R.; Francisquetti, E.L.; Andrade, M.Z.; Zattera, A.J., E-mail: ajzatter@ucs.b [Universidade de Caxias do Sul (UCS), RS (Brazil). Lab. de Polimeros

    2010-07-01

    Polymeric nanocomposites have some superior properties when compared to conventional polymer composites and is one of the most promising fields in the nanotechnology research. In a EVA (ethylene vinyl acetate) /PVC (poly vinyl chloride) matrix was incorporated different types of montmorillonite clays (an inorganic (Na{sup +}) and two organic modified (15A and 30B nanoclays). The mixtures were processed in a co-rotating twin-screw extruder at processing speeds of 200 and 400 rpm. Thermogravimetric analysis (TGA) shown that the inorganic and organic modified clays promoted a shift to higher temperatures in the degradation temperature., X-ray diffraction (XRD) and transmission electronic microscopy (TEM) shows a possible intercalation with the 15A clay, exfoliation with the 30B clay and formation of clusters in the Na{sup +} clay. For all clays studied, the increase in shear rate does not promote significant changes. (author)

  10. Electrochemical Sensors Based on Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Md. Aminur Rahman

    2009-03-01

    Full Text Available This review focuses on recent contributions in the development of the electrochemical sensors based on carbon nanotubes (CNTs. CNTs have unique mechanical and electronic properties, combined with chemical stability, and behave electrically as a metal or semiconductor, depending on their structure. For sensing applications, CNTs have many advantages such as small size with larger surface area, excellent electron transfer promoting ability when used as electrodes modifier in electrochemical reactions, and easy protein immobilization with retention of its activity for potential biosensors. CNTs play an important role in the performance of electrochemical biosensors, immunosensors, and DNA biosensors. Various methods have been developed for the design of sensors using CNTs in recent years. Herein we summarize the applications of CNTs in the construction of electrochemical sensors and biosensors along with other nanomaterials and conducting polymers.

  11. Fabrication of strain gauge based sensors for tactile skins

    Science.gov (United States)

    Baptist, Joshua R.; Zhang, Ruoshi; Wei, Danming; Saadatzi, Mohammad Nasser; Popa, Dan O.

    2017-05-01

    Fabricating cost effective, reliable and functional sensors for electronic skins has been a challenging undertaking for the last several decades. Application of such skins include haptic interfaces, robotic manipulation, and physical human-robot interaction. Much of our recent work has focused on producing compliant sensors that can be easily formed around objects to sense normal, tension, or shear forces. Our past designs have involved the use of flexible sensors and interconnects fabricated on Kapton substrates, and piezoresistive inks that are 3D printed using Electro Hydro Dynamic (EHD) jetting onto interdigitated electrode (IDE) structures. However, EHD print heads require a specialized nozzle and the application of a high-voltage electric field; for which, tuning process parameters can be difficult based on the choice of inks and substrates. Therefore, in this paper we explore sensor fabrication techniques using a novel wet lift-off photolithographic technique for patterning the base polymer piezoresistive material, specifically Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) or PEDOT:PSS. Fabricated sensors are electrically and thermally characterized, and temperaturecompensated designs are proposed and validated. Packaging techniques for sensors in polymer encapsulants are proposed and demonstrated to produce a tactile interface device for a robot.

  12. Potential use of ground-based sensor technologies for weed detection.

    Science.gov (United States)

    Peteinatos, Gerassimos G; Weis, Martin; Andújar, Dionisio; Rueda Ayala, Victor; Gerhards, Roland

    2014-02-01

    Site-specific weed management is the part of precision agriculture (PA) that tries to effectively control weed infestations with the least economical and environmental burdens. This can be achieved with the aid of ground-based or near-range sensors in combination with decision rules and precise application technologies. Near-range sensor technologies, developed for mounting on a vehicle, have been emerging for PA applications during the last three decades. These technologies focus on identifying plants and measuring their physiological status with the aid of their spectral and morphological characteristics. Cameras, spectrometers, fluorometers and distance sensors are the most prominent sensors for PA applications. The objective of this article is to describe-ground based sensors that have the potential to be used for weed detection and measurement of weed infestation level. An overview of current sensor systems is presented, describing their concepts, results that have been achieved, already utilized commercial systems and problems that persist. A perspective for the development of these sensors is given. © 2013 Society of Chemical Industry.

  13. Research on Bridge Sensor Validation Based on Correlation in Cluster

    Directory of Open Access Journals (Sweden)

    Huang Xiaowei

    2016-01-01

    Full Text Available In order to avoid the false alarm and alarm failure caused by sensor malfunction or failure, it has been critical to diagnose the fault and analyze the failure of the sensor measuring system in major infrastructures. Based on the real time monitoring of bridges and the study on the correlation probability distribution between multisensors adopted in the fault diagnosis system, a clustering algorithm based on k-medoid is proposed, by dividing sensors of the same type into k clusters. Meanwhile, the value of k is optimized by a specially designed evaluation function. Along with the further study of the correlation of sensors within the same cluster, this paper presents the definition and corresponding calculation algorithm of the sensor’s validation. The algorithm is applied to the analysis of the sensor data from an actual health monitoring system. The result reveals that the algorithm can not only accurately measure the failure degree and orientate the malfunction in time domain but also quantitatively evaluate the performance of sensors and eliminate error of diagnosis caused by the failure of the reference sensor.

  14. Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.

    Science.gov (United States)

    Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho

    2016-03-15

    Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Chemical sensors based on molecularly modified metallic nanoparticles

    International Nuclear Information System (INIS)

    Haick, Hossam

    2007-01-01

    This paper presents a concise, although admittedly non-exhaustive, didactic review of some of the main concepts and approaches related to the use of molecularly modified metal nanoparticles in or as chemical sensors. This paper attempts to pull together different views and terminologies used in sensors based on molecularly modified metal nanoparticles, including those established upon electrochemical, optical, surface Plasmon resonance, piezoelectric and electrical transduction approaches. Finally, this paper discusses briefly the main advantages and disadvantages of each of the presented class of sensors. (review article)

  16. Image-based environmental monitoring sensor application using an embedded wireless sensor network.

    Science.gov (United States)

    Paek, Jeongyeup; Hicks, John; Coe, Sharon; Govindan, Ramesh

    2014-08-28

    This article discusses the experiences from the development and deployment of two image-based environmental monitoring sensor applications using an embedded wireless sensor network. Our system uses low-power image sensors and the Tenet general purpose sensing system for tiered embedded wireless sensor networks. It leverages Tenet's built-in support for reliable delivery of high rate sensing data, scalability and its flexible scripting language, which enables mote-side image compression and the ease of deployment. Our first deployment of a pitfall trap monitoring application at the James San Cannot Mountain Reserve provided us with insights and lessons learned into the deployment of and compression schemes for these embedded wireless imaging systems. Our three month-long deployment of a bird nest monitoring application resulted in over 100,000 images collected from a 19-camera node network deployed over an area of 0.05 square miles, despite highly variable environmental conditions. Our biologists found the on-line, near-real-time access to images to be useful for obtaining data on answering their biological questions.

  17. Image-Based Environmental Monitoring Sensor Application Using an Embedded Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Jeongyeup Paek

    2014-08-01

    Full Text Available This article discusses the experiences from the development and deployment of two image-based environmental monitoring sensor applications using an embedded wireless sensor network. Our system uses low-power image sensors and the Tenet general purpose sensing system for tiered embedded wireless sensor networks. It leverages Tenet’s built-in support for reliable delivery of high rate sensing data, scalability and its flexible scripting language, which enables mote-side image compression and the ease of deployment. Our first deployment of a pitfall trap monitoring application at the James San Jacinto Mountain Reserve provided us with insights and lessons learned into the deployment of and compression schemes for these embedded wireless imaging systems. Our three month-long deployment of a bird nest monitoring application resulted in over 100,000 images collected from a 19-camera node network deployed over an area of 0.05 square miles, despite highly variable environmental conditions. Our biologists found the on-line, near-real-time access to images to be useful for obtaining data on answering their biological questions.

  18. A general framework for sensor-based human activity recognition.

    Science.gov (United States)

    Köping, Lukas; Shirahama, Kimiaki; Grzegorzek, Marcin

    2018-04-01

    Today's wearable devices like smartphones, smartwatches and intelligent glasses collect a large amount of data from their built-in sensors like accelerometers and gyroscopes. These data can be used to identify a person's current activity and in turn can be utilised for applications in the field of personal fitness assistants or elderly care. However, developing such systems is subject to certain restrictions: (i) since more and more new sensors will be available in the future, activity recognition systems should be able to integrate these new sensors with a small amount of manual effort and (ii) such systems should avoid high acquisition costs for computational power. We propose a general framework that achieves an effective data integration based on the following two characteristics: Firstly, a smartphone is used to gather and temporally store data from different sensors and transfer these data to a central server. Thus, various sensors can be integrated into the system as long as they have programming interfaces to communicate with the smartphone. The second characteristic is a codebook-based feature learning approach that can encode data from each sensor into an effective feature vector only by tuning a few intuitive parameters. In the experiments, the framework is realised as a real-time activity recognition system that integrates eight sensors from a smartphone, smartwatch and smartglasses, and its effectiveness is validated from different perspectives such as accuracies, sensor combinations and sampling rates. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Organophosphorus pesticide exposure in agriculture: effects of temperature, ultraviolet light and abrasion on PVC gloves

    Science.gov (United States)

    ISMAIL, Ismaniza; GASKIN, Sharyn; PISANIELLO, Dino; EDWARDS, John W.

    2017-01-01

    Elbow length PVC gloves are often recommended for protection against organophosphorus pesticide (OP) exposure in agriculture. However, performance may be reduced due to high temperature, UV exposure and abrasion. We sought to assess these impacts for two OPs under normal use and reasonable worst-case scenarios. Glove permeation tests were conducted using ASTM cells with two PVC glove brands at 23°C and 45°C for up to 8 h. Technical grade dichlorvos and formulated diazinon were used undiluted and at application strength. Breakthough of undiluted dichlorvos occurred at both 23°C and 45°C, but only at 45°C for application strength. Breakthrough of diazinon was not achieved, except when undiluted at 45°C. UV-exposed and abraded gloves showed reduced performance, with the effect being approximately two-fold for dichlorvos. Only small differences were noted between glove brands. Extra precautions should be taken when handling concentrated OPs at high temperature, or when using abraded or sunlight-exposed gloves. PMID:29199264

  20. Pristine carbon nanotubes based resistive temperature sensor

    International Nuclear Information System (INIS)

    Alam, Md Bayazeed; Saini, Sudhir Kumar; Sharma, Daya Shankar; Agarwal, Pankaj B.

    2016-01-01

    A good sensor must be highly sensitive, faster in response, of low cost cum easily producible, and highly reliable. Incorporation of nano-dimensional particles/ wires makes conventional sensors more effective in terms of fulfilling the above requirements. For example, Carbon Nanotubes (CNTs) are promising sensing element because of its large aspect ratio, unique electronic and thermal properties. In addition to their use for widely reported chemical sensing, it has also been explored for temperature sensing. This paper presents the fabrication of CNTs based temperature sensor, prepared on silicon substrate using low cost spray coating method, which is reliable and reproducible method to prepare uniform CNTs thin films on any substrate. Besides this, simple and inexpensive method of preparation of dispersion of single walled CNTs (SWNTs) in 1,2 dichlorobenzene by using probe type ultrasonicator for debundling the CNTs for improving sensor response were used. The electrical contacts over the dispersed SWNTs were taken using silver paste electrodes. Fabricated sensors clearly show immediate change in resistance as a response to change in temperature of SWNTs. The measured sensitivity (change in resistance with temperature) of the sensor was found ∼ 0.29%/°C in the 25°C to 60°C temperature range.