WorldWideScience

Sample records for pv phaseoli isolates

  1. Characterization of Xanthomonas axonopodis pv. phaseoli isolates

    NARCIS (Netherlands)

    Nunes, W.M.C.; Corazza, M.J.; De Souza, S.A.C.D.; Tsai, S.M.; Kuramae, E.E.

    2008-01-01

    A simple, quick and easy protocol was standardized for extraction of total DNA of the bacteria Xanthomonas axonopodis pv. phaseoli. The DNA obtained by this method had high quality and the quantity was enough for the Random Amplified Polymorphic DNA (RAPD) reactions with random primers, and

  2. Characterization of Xanthomonas axonopodis pv. phaseoli isolates

    NARCIS (Netherlands)

    Nunes, W.M.C.; Corazza, M.J.; De Souza, S.A.C.D.; Tsai, S.M.; Kuramae, E.E.

    2008-01-01

    A simple, quick and easy protocol was standardized for extraction of total DNA of the bacteria Xanthomonas axonopodis pv. phaseoli. The DNA obtained by this method had high quality and the quantity was enough for the Random Amplified Polymorphic DNA (RAPD) reactions with random primers, and Polymera

  3. Cloning of a two-component signal transduction system of Xanthomonas campestris pv. phaseoli var. fuscans strain BXPF65

    DEFF Research Database (Denmark)

    Chan, JWYF; Maynard, Scott; Goodwin, PH

    1998-01-01

    A putative two-component signal transduction system was amplified and cloned from the plant pathogenic bacterium Xanthomonas campestris pv. phaseoli var. fuscans isolate BXPF65. The 620 bp amplified fragment was sequenced and analyzed with the BLAST Enhanced Alignment Utility (BEAUTY). BEAUTY ana...

  4. Genome sequencing reveals a new lineage associated with lablab bean and genetic exchange between Xanthomonas axonopodis pv. phaseoli and Xanthomonas fuscans subsp. fuscans

    Directory of Open Access Journals (Sweden)

    Valente eAritua

    2015-10-01

    Full Text Available Common bacterial blight is a devastating seed-borne disease of common beans that also occurs on other legume species including lablab and Lima beans. We sequenced and analysed the genomes of 26 isolates of Xanthomonas axonopodis pv. phaseoli and X. fuscans subsp. fuscans, the causative agents of this disease, collected over four decades and six continents. This revealed considerable genetic variation within both taxa, encompassing both single-nucleotide variants and differences in gene content, that could be exploited for tracking pathogen spread. The bacterial isolate from Lima bean fell within the previously described Genetic Lineage 1, along with the pathovar type isolate (NCPPB 3035. The isolates from lablab represent a new, previously unknown genetic lineage closely related to strains of X. axonopodis pv. glycines. Finally, we identified more than 100 genes that appear to have been recently acquired by Xanthomonas axonopodis pv. phaseoli from X. fuscans subsp. fuscans.

  5. Reação de genótipos de feijoeiro comum a Fusarium oxysporum f. sp. phaseoli, Macrophomina phaseolina e Xanthomonas campestris pv. phaseoli Behavior of dry bean genotypes to Fusarium oxysporum f. sp. phaseoli, Macrophomina phaseolina, and Xanthomonas campestris pv. phaseoli

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Maringoni

    1999-04-01

    Full Text Available Foi avaliado no presente trabalho o comportamento dos genótipos de feijoeiro (Phaseolus vulgaris L. PI 150414, PI 163117, PI 175829 branco, PI 175829 roxo, PI 175858, PI 197687, A 417, A 420, A 429, Xan 160, Xan 161, WISHBR 40 e IAC Carioca inoculados com Fusarium oxysporum f. sp. phaseoli, Macrophomina phaseolina e Xanthomonas campestris pv. phaseoli, sob condições de telado/casa de vegetação. Verificou-se que os genótipos Xan 160, PI 150414, A 417, PI 175829 roxo, Xan 161, A 420, PI 163117 e PI 175829 branco foram resistentes a F. oxysporum f. sp. phaseoli e somente o PI 175829 branco apresentou bom nível de resistência a M. phaseolina. Com relação ao comportamento desses genótipos a X. campestris pv. phaseoli, eles foram altamente suscetíveis ao isolado Feij-4 e apenas o genótipo Xan 161 apresentou nível moderado de resistência foliar ao isolado Feij-41.The behavior of dry bean (Phaseolus vulgaris L. genotypes PI 150414, PI 163117, PI 175829 white, PI 175829 purple, PI 175858, PI 197687, A 417, A 420, A 429, Xan 160, Xan 161, WISHBR 40, and IAC Carioca inoculated with Fusarium oxysporum f. sp. phaseoli, Macrophomina phaseolina, and Xanthomonas campestris pv. phaseoli was evaluated under greenhouse condition. The bean genotypes Xan 160, PI 150414, A 417, PI 175829 purple, Xan 161, A 420, PI 163117, and PI 175829 white were resistant to F. oxysporum f. sp. phaseoli, and only PI 155829 white had a good level of resistance to M. phaseolina. All bean genotypes were susceptible to Feij-4 strain, and only Xan 161 had some level of leaf resistance to Feij-41 strain of X. campestris pv. phaseoli.

  6. Bioassay for selection of biocontroller bacteria against bean common blight (Xanthomonas axonopodis pv. phaseoli Bioensaio para seleção de bactérias biocontroladoras do crestamento bacteriano comum do feijão (Xanthomonas axonopodis pv. phaseoli

    Directory of Open Access Journals (Sweden)

    Zarela G.C.N. Zanatta

    2007-09-01

    Full Text Available Emphasis has been given on selection of micro-organism for biological control. However, in order to evaluate the biological control potential of a great number of micro-organisms in a small period of time it is necessary to develop an efficient bioassay. Seven hundred and sixty bacterial isolates from different habitats, were selected for compatibility with Rhizobium leguminosarum bv. phaseoli (SEMIA 4077 e SEMIA 4080. Among them 596 isolates were ineffective against both rhizobia. Bean seeds immersed in suspension of each one of these isolates were agitated for 5 hours at 10ºC and sowed in non-sterilized soil. The plants were kept in greenhouse. After the development of cotyledonary and primary leaves, these were removed and bioassayed for Xanthomonas axonopodis pv. phaseoli (XAP control. In the cotyledonary leaves, it was observed that the isolate DFs093 offered 100% control, DFs041 and DFs1297 offered 90% and DFs490, DFs769, DFs831, DFs842 and DFs843 offered 80% control. In the primary leaves, the DFs482 isolated offered 100% and the DFs080, DFs348, DFs513, DFs622, DFs769, DFs842 and DFs912 offered 80% of XAP control.Tem-se dado muita ênfase ao controle biológico mediante seleção de microorganismos. Porém, para se avaliar o potencial de biocontroladores de forma massal e em pequeno intervalo de tempo é necessário desenvolver um bioensaio eficiente. Bactérias de diferentes sítios, num total de 760 isolados, foram selecionadas para compatibilidade com Rhizobium leguminosarum bv. phaseoli estirpes SEMIA 4077 e SEMIA 4080, onde 596 isolados foram inefetivos contra ambos rizóbios. Sementes de feijão foram imersas em suspensão de cada um destes isolados sendo agitadas por 5 horas a 10ºC, plantadas em solo não esterelizado, sendo as plantas mantidas em casa de vegetação. Após o desenvolvimento das folhas cotiledonares e folhas primárias, estas foram retiradas e avaliadas por bioensaio para o controle de Xanthomonas axonopodis pv

  7. Estrategias para diferenciar xanthomonas campestris pv. phaseoli con sales inorgánicas

    Directory of Open Access Journals (Sweden)

    Mildred Zapata

    2001-01-01

    Full Text Available Colonias de Xanthomonas campestris pv. phaseoli (Xcp aisladas de hojas de habichuelas con síntomas de tizón común en Puerto Rico, República Dominicana y Costa Rica fueron caracterizadas como patogénicas en hojas de Phaseolus vulgaris. Sin embargo, éstas fueron clasificadas en los patovares phaseoli, vesicatoria, carotae y xanthosoma por el sistema Biolog. Las cepas de Xcp crecidas en 2, 3, 5-Trifenil cloruro de tetrazolio (TTC mostraron colonias convexas, brillosas, lisas y de color rojo en diferentes tamaños. TTC fue reducido por las cepas de Xcp a un pigmento rojo intenso, un formazán de trifenilo. No se encontraron diferencias en virulencia y tipos de colonias en las cepas identificadas por pruebas de patogenicidad como Xcp. Por otro lado, hubo diferencias en el tipo de colonia en cultivos bacterianos identificados como: Pseudomonas cissicola, P. fulva, Corynebacterium, Rhodococcus, y Shingomonas

  8. Occurrence of Xanthomonas axonopodis pv. phaseoli, the causal agent of common bacterial blight disease, on seeds of common bean (Phaseolus vulgaris L.) in upper Egypt.

    Science.gov (United States)

    Abd-Alla, M H; Bashandy, S R; Schnell, S

    2010-01-01

    Common bean seed lots collected from different seed dealers and Malawii agriculture station were screened for the presence of Xanthomonas axonopodis pv. phaseoli. In the laboratory the pathogen was isolated following the routine laboratory assay method, i.e. direct plating method using yeast extract-dextrose-calcium carbonate agar medium (YDC). Yellow, convex, mucoid colonies of Xanthomonas were consistently isolated on YDC from seed samples. The presumptive pathogen was confirmed by isolation on semiselective medium, such as mTBM and MD5A. Further, the pathogen was confirmed by biochemical, physiological and, finally, the pathogenicity tests. Five samples out of seven were positive for Xanthomonas. The isolates were found to cause common blight of 3-week-old common bean plants by 7 d after inoculation. Bacteria with the same characteristics as those inoculated were re-isolated from the infected plants.

  9. Genotipos de frijol (Phaseolus Vulgaris l. resistentes a Xanthomonas campestris pv. phaseoli de Mexico

    Directory of Open Access Journals (Sweden)

    Rosa Navarrete

    2000-01-01

    Full Text Available Genotipos de frijol (Phaseolus vulgaris L. resistentes a Xanthomonas campestris pv. phaseoli de México. Durante 1995 se evaluó la reacción de genotipos de frijol de diversos origenes a Xcp, bajo condiciones de invernadero en el Campo Experimental del Valle de México, del INIFAP. Se realizaron tres experimentos con a120, b44 y csiete genotipos de frijol. Las plantas se inocularon por corte con navajas en la etapa V3, a y b con una mezcla de nueve cepas de Xcp y el c, con cada una de siete cepas con diferente grado de patogenicidad. La severidad se evaluó 20 días después de la inoculación, por comparación con una escala visual de nueve grados. Los datos se analizaron bajo un diseño completamente al azar. En a, los genotipos que mostraron reacción de resistencia a Xcp fueron: A 36, A 475, G 5686, G 11867, Harowood, SEA 14, XAN 266, MCD 4012 y REN 27. En b los genotipos resistentes fueron: Sequía Durango, Taylor y XAN 30. En los experimentos anteriores la severidad de la enfermedad mostró una distribución normal, con el máximo número de genotipos en el grado de severidad cinco en a y seis en b. Los resultados obtenidos indican que el uso de mezclas de cepas de bacterias con diferente patogenicidad es eficiente para identificar genotipos de frijol resistentes a Xcp. Los genotipos resistentes identificados en el último experimento, mostraron respuesta diferencial e interacciones genotipo por cepa. REN 27 y SEA 14 mostraron resistencia a las cepas utilizadas

  10. Alterações metabólicas em plantas de feijão originadas de sementes microbiolizadas por Pseudomonas sp. e inoculadas com Xanthomonas axonopodis pv. phaseoli Metabolic alterations on bean plants originated from microbiolization of seeds with Pseudomonas sp. and inoculated with Xanthomnas axonopodis pv. phaseoli

    Directory of Open Access Journals (Sweden)

    Eliane Gonçalves da Silva

    2009-06-01

    . Em relação à atividade de PO houve redução da mesma nas plantas tratadas com o isolado de Pseudomonas (DFs842. Esses resultados evidenciaram que a microbiolização das sementes provocou alterações metabólicas nas plantas delas originadas, pelo aumento do teor de PST e atividade de PPO, indicando uma provável participação destas enzimas na indução de resistência ativada pela microbiolização com o isolado de Pseudomonas (DFs842.Many enzymes are involved in plant defense against pathogens. The purpose of this study was to verify alterations in activity of some enzymes in bean plants originated from microbiolization of seeds with a fluorescent isolate (DFs842 of Pseudomonas. Bean seeds (cv. "BRS Valente" were immersed in a bacterial suspension of a 24 hours old Pseudomonas culture (OD540=0,5 known as a Xanthomonas axonopodis pv. phaseoli biocontroler. Check treatment consisted of seeds immersed in a saline solution (NaCl 0,85%. After microbiolization for 5 hours at 10ºC, seeds were sowed in a non sterilized substrate composed of soil, sand and bovine manure mixture (3:1:1 ratio disposed in pots in a greenhouse. The pathogen was inoculated by cutting the third true leaves with scissors previously immersed in the bacterial suspension (X. axonopodis pv. phaseoli prepared from a 24 hours old culture (OD540=0,4. Plants were kept in moister chambers for 24 hours before and after the inoculation. For protein extraction preparation, the three true leaves were collected individually at five different times: immediately before inoculation and 6, 24, 72 hours and 15 days after inoculation. The leaf extract was used for determination of total soluble proteins (TSP, and the activity of polyphenol oxidase (PPO and peroxidase (PO by spectrophometry. The results showed a significant increase in TSP content and PPO activity in plants treated with the isolated DFs842, when TSP content was the double of the non-treated plants. It was also observed that, even before

  11. Meio semi-seletivo para detectar Xanthomonas axonopodis pv. phaseoli em sementes de feijoeiro e sua erradicação através do tratamento de sementes com o fungicida tolylfluanid A semi-selective medium to detect Xanthomonas axonopodis pv. phaseoli in bean seeds and its eradication through seed treatment with tolylfluanid

    Directory of Open Access Journals (Sweden)

    Lucilene Paula Lopes

    2008-09-01

    Full Text Available Estudou-se a eficiência do meio semi-seletivo desenvolvido para Xanthomonas axonopodis pv. malvacearum (Xam do algodoeiro, com algumas modificações, na detecção de Xanthomonas axonopodis pv. phaseoli (Xap em sementes de feijoeiro, bem como a eficiência do fungicida tolylfluanid na erradicação de Xap através do tratamento de sementes. Foram utilizadas sementes naturalmente infectadas por Xap, procedentes de diferentes municípios do Estado do Paraná. Houve o desenvolvimento de colônias bacterianas ao redor das sementes infectadas sob meio semi-seletivo entre seis e 12 dias de incubação. A freqüência de recuperação de colônias da bactéria em relação ao meio Agar nutriente (AN variou entre 30 a 112%. O crescimento de Xap foi inibido a concentrações entre 54 a 1500 ppm do fungicida tolylfluanid. A bactéria foi recuperada das sementes não tratadas em meio semi-seletivo, mas não das sementes tratadas em solução do fungicida tolylfluanid (1,20g/L água. Em casa de vegetação, das 400 sementes tratadas com tolylfluanid não foi produzida nenhuma planta com sintomas da doença até 30 dias após a semeadura, enquanto que 9,75% das sementes não tratadas apresentaram sintomas de Xap. Em um outro experimento, das 1200 sementes não tratadas um total de 7,08% e 11,67% das plantas mostraram-se com sintomas da doença, enquanto que das sementes tratadas 0,5% e 2,4% apresentaram sintomas, 26 e 46 dias após a semeadura, respectivamente.The efficiency of a semi-selective medium developed for Xanthomonas axonopidis pv. malvacearum (Xam, was verified with some modifications, in detecting the presence of X. axonopodis pv. phaseoli (Xap in bean seed. Seed samples naturally infected with Xap were collected from the State of Paraná. The bacterial growth developed around the infected seed in the semi-selective medium after 12 days after incubation. The recovery frequency of bacterial colonies in relation to nutrient agar varied between 30

  12. Otimização da técnica de PCR para a detecção de Xanthomonas axonopodis pv. phaseoli em sementes de feijão Optimization of PCR technique for detection of Xanthomonas axonopodis pv. phaseoli in bean seeds

    Directory of Open Access Journals (Sweden)

    Franklin Cordeiro Silva

    2013-03-01

    Full Text Available O crestamento bacteriano comum, causado por Xanthomonas axonopodis pv. phaseoli (Xap, é a principal bacteriose do feijoeiro no Brasil, sendo transmitida principalmente por sementes. O presente trabalho teve como objetivo aperfeiçoar uma técnica, por meio de diferentes métodos de preparação do extrato, para a detecção de Xap, bem como sua detecção simultânea com Curtobacterium flaccumfaciens pv. flaccumfaciens (Cff nos extratos de sementes de feijão,via PCR. A partir de amostras de sementes de feijão inoculadas artificialmente com Xap e lotes comerciais, foram avaliados: extrato bruto obtido diretamente das sementes, extrato concentrado por filtração em membrana de 0,22µM de diâmetro, extrato concentrado por centrifugação e extrato plaqueado em meio semi-seletivo XCP1 com e sem antibióticos (BIO-PCR. Avaliou-se a presença simultânea de Xap e Cff em 10 lotes comerciais de sementes de feijão através da reação multiplex, utilizandos-se os primers X4c, X4e, CffFOR2 e CffREV4. A partir do extrato bruto, do extrato concentrado por centrifugação e por filtragem em membrana Millipore® não foi possível a detecção de Xap nas sementes de feijão artificialmente contaminadas nem nos 47 lotes comerciais de sementes/ grãos de feijão. A técnica de BIO-PCR permitiu a detecção de Xap a partir de extratos de sementes de feijão artificialmente contaminadas e em 18 dos 47 lotes comerciais. A técnica de detecção simultânea de Xap e Cff no mesmo gel é viável, por amplificar fragmentos de DNA típicos de cada fitobactéria. O uso do meio de cultura XCP1 sem adição de antibióticos permitiu detectar Xap com período de incubação menor em um dia em comparação à detecção utilizando-se o meio de cultura com antibióticosCommon bacterial blight, caused by Xanthomonas axonopodis pv. phaseoli (Xap, is the major bacteriosis affecting bean plants in Brazil and is mainly transmitted by seeds. This study aimed to improve a

  13. Isolation of Rhizobium phaseoli Tn5-induced mutants with altered expression of cytochrome terminal oxidases o and aa3.

    Science.gov (United States)

    Soberón, M; Membrillo-Hernández, J; Aguilar, G R; Sánchez, F

    1990-01-01

    Two Rhizobium phaseoli mutants affected in cytochrome expression were obtained by Tn5-mob mutagenesis of the wild-type strain (CE3). Mutant strain CFN031 expressed sevenfold less cytochrome o in culture, expressed cytochrome aa3 under microaerophilic culture conditions, in contrast to strain CE3, and was affected in its vegetative growth properties and proliferation inside plant host cells. Mutant CFN037 expressed cytochrome aa3 under microaerophilic culture conditions, while bacteroid development and nitrogen fixation occurred earlier than in strain CE3. Images FIG. 2 PMID:2155209

  14. RESPUESTA A BACTERIOSIS COMÚN (Xanthomonas axonopodis p.v phaseoli EN LOS CULTIVARES COMERCIALES DE FRIJOL COMÚN DE CUBA, EN CONDICIONES DE CAMPO. AFECTACIÓN DE LOS RENDIMIENTOS POR EFECTO DE LA INOCULACIÓN

    Directory of Open Access Journals (Sweden)

    Odile Rodríguez Miranda

    2015-01-01

    Full Text Available En el germoplasma de frijol común (Phaseolus vulgaris L., en Cuba, es posible identificar cultivares con niveles de resistencia ante un aislamiento patogénico de Xanthomonas axonopodis pv. phaseoli, a fin de disminuir las pérdidas y aumentar el rendimiento promedio del cultivo en campos infectados con este patógeno. Los objetivos de este trabajo estuvieron dirigidos a evaluar, en genotipos de frijol común respuestas contrastantes frente a la incidencia natural e inoculación del aislamiento patogénico Xap527 (Xanthomonas axonopodis; identificar los cultivares comerciales con mejor comportamiento en follaje y vainas y con menores pérdidas de rendimiento en campos infectados por este patógeno. Los resultados permitieron seleccionar los genotipos de frijol, con buen comportamiento frente al aislamiento de Xap estudiado y se determinó la disminución del rendimiento en los cultivares de frijol por su reacción de susceptibilidad frente a Bacteriosis común, con la inoculación del aislamiento Xap 527, de Cuba

  15. Molecular characterization of Pseudomonas syringae pv. tomato isolates from Tanzania

    DEFF Research Database (Denmark)

    Shenge, K.C.; Stephan, D.; Mabagala, R. B.

    2008-01-01

    pathogenicity assays on tomato, carbon source utilization by the Biolog Microplate system, polymerase chain reaction and restriction fragment length polymorphism (RFLP) analysis. All the P. syringae pv. tomato isolates produced bacterial speck symptoms on susceptible tomato (cv. ‘Tanya') seedlings. Metabolic...

  16. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France.

    Science.gov (United States)

    Cunty, Amandine; Cesbron, Sophie; Briand, Martial; Carrère, Sébastien; Poliakoff, Françoise; Jacques, Marie-Agnès; Manceau, Charles

    2016-01-01

    Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae.

  17. Draft genome sequences of five Pseudomonas syringae pv. actinidifoliorum strains isolated in France

    Directory of Open Access Journals (Sweden)

    Amandine Cunty

    Full Text Available ABSTRACT Pseudomonas syringae pv. actinidifoliorum causes necrotic spots on the leaves of Actinidia deliciosa and Actinidia chinensis. P. syringae pv. actinidifoliorum has been detected in New Zealand, Australia, France and Spain. Four lineages were previously identified within the P. syringae pv. actinidifoliorum species group. Here, we report the draft genome sequences of five strains of P. syringae pv. actinidifoliorum representative of lineages 1, 2 and 4, isolated in France. The whole genomes of strains isolated in New Zealand, representative of P. syringae pv. actinidifoliorum lineages 1 and 3, were previously sequenced. The availability of supplementary P. syringae pv. actinidifoliorum genome sequences will be useful for developing molecular tools for pathogen detection and for performing comparative genomic analyses to study the relationship between P. syringae pv. actinidifoliorum and other kiwifruit pathogens, such as P. syringae pv. actinidiae.

  18. Draft genome sequences of pseudomonas syringae pv. syringae ALF3 isolated from alfalfa

    Science.gov (United States)

    We report the annotated draft genome of Pseudomonas syringae pv. syringae strain ALF3, isolated in Wyoming, USA. Comparison of this genome sequence with those of closely related strains of P. syringae pv. syringae adapted to other hosts will facilitate research into interactions between this pathoge...

  19. H6 Non-isolated Full Bridge Grid-connected PV Inverters With Low Leakage Currents

    Institute of Scientific and Technical Information of China (English)

    ZHANG Li; SUN Kai; FENG Lanlan; XING Yan; XU Ming

    2012-01-01

    Non-isolated inverter topologies have obtained more attentions in photovoltaic (PV) generation system since they are featured by higher efficiency and lower cost. In order to meet the safety requirement for the non-isolated grid-tied PV inverter, the common-mode leakage current is required to be carefully tackled due to the absence of the transformer. A H6 non-isolated full bridge PV grid-connected inverter is proposed to meet the limit for common-mode leakage current in grid-tied PV generation systems, as shown in Fig. 1.

  20. Stability Analysis for Isolated AC Microgrids Based on PV-Active Generators

    DEFF Research Database (Denmark)

    Aldana, Nelson Leonardo Diaz; Coelho, Ernane A. A.; Quintero, Juan Carlos Vasquez;

    2015-01-01

    The current trend in isolated microgrids is oriented to distributed renewable energy generators, such as photovoltaic (PV) generators and their corresponding distributed energy storage systems (ESS) as an unit denoted as active generator (PV+ESS). In an isolated microgrid, every distributed...... for all the distributed generators. In particular, ESS’s based on batteries require at least two different mode of charge. As consequence, the topological operation mode of the microgrid is affected by the changes of the operation mode of each distributed generator. Typically, droop control loops are used...... for interconnecting several different distributed generators in parallel to a common bus, whose parameters determine the stability and damping of the microgrid operation. In this paper, a small-signal stability analysis is applied to an isolated AC microgrid composed of (PV+ESS) active generators, regarding three...

  1. Pseudomonas syringae pv. phaseolicola isolated from weeds in bean crop fields.

    Science.gov (United States)

    Fernández-Sanz, A M; Rodicio, M R; González, A J

    2016-04-01

    Pseudomonas syringae pv. phaseolicola, the causative agent of halo blight in common bean (Phaseolus vulgaris L.), was isolated from weeds associated with bean crops in Spain. The bacterium was recovered from Fumaria sp, Mercurialis annua, Solanum nigrum and Sonchus oleraceus. Ps. s. pv. phaseolicola had previously been isolated from leguminous plants and S. nigrum, but to our knowledge, this is the first time it was recovered from the other three species. The isolates were phenotypically and genetically characterized, and they were compared with isolates recovered from common beans. Five different genotypic profiles were detected by PmeI-PFGE, two of them being of new description. Weed isolates were as pathogenic on bean plants as bean isolates, but they were not pathogenic on S. nigrum. Regarding the survival of the pathogen in weeds, Ps. s. pv. phaseolicola was isolated from So. oleraceus 11 weeks after the end of the bean crop. These results strongly support the idea of weeds as a potential source of inoculum for halo blight in bean. It has traditionally been considered that the main source of inoculum of Pseudomonas syringae pv. phaseolicola causing halo blight disease in Phaseolus vulgaris are the bean seeds, and that the host range of the bacterium is almost restricted to leguminous plants. In this study, the bacterium was recovered from four nonleguminous weed species collected in bean fields, and its permanence in weeds for at least 11 weeks after the harvesting of the beans was demonstrated. We have also proved that the strains isolated from weeds were pathogenic on bean plants. Accordingly, the host range of Ps. s. pv. phaseolicola could be broader than previously thought and weeds appear to be acting as a reservoir of the pathogen until the next crop. © 2016 The Society for Applied Microbiology.

  2. Caracterização de isolados de Xanthomonas axonopodis pv. manihotis = Characterization of isolates of Xanthomonas axonopodis pv. manihotis

    Directory of Open Access Journals (Sweden)

    Roberto Luis Portz

    2006-07-01

    Full Text Available A bacteriose (Xanthomonas axonopodis pv. manihotis e a doenca de maior importancia economica na cultura da mandioca. Para estudar a variabilidade genetica desta bacteria no Oeste do Parana, foram realizados levantamentos em Entre Rios do Oeste, Marechal Candido Rondon, Mercedes, Missal, Nova Santa Rosa e Pato Bragado. Os isolados foram caracterizados em relacao a atividade de amilase, ƒ¿ e ƒÀ-esterase e agressividade. Dos 61 materiais vegetais coletados, obtiveram-se 19 isolados da bacteria, com maior incidencia para variedades de mesa em relacao aqueles para industria. Manivas provenientes de Pato Bragado, Entre Rios do Oeste e Mercedes apresentaram incidencias de 10, 27 e 10%, respectivamente, valores inferiores aos de Marechal Candido Rondon (50% e Nova Santa Rosa (58%. Os isolados foram agrupados em cinco, seis e 12 grupos em relacao a capacidade amilolitica, agressividade e isoenzimas de esterase, respectivamente. Nao houve relacao entre atividade de amilase e agressividade. Isolados de Marechal Candido Rondon foram mais agressivos que os provenientes das outras regioes. O agrupamento com base em esterase permitiu verificar que isolados provenientes de Entre Rios do Oeste, Nova Santa Rosa e Mercedes apresentaram alto grau de similaridade. Estes resultados indicam haver diferenciacaoentre os isolados da bacteria presentes nos municipios amostrados.The bacterial blight (Xanthomonas axonopodis pv. manihotis is the most important disease of cassava. To study the genetic variability of pathogen in the West of Parana, a research was carried out at Entre Rios do Oeste, Marechal Candido Rondon, Mercedes, Missal, Nova Santa Rosa and Pato Bragado. The isolates were characterized to amylase activity, ƒ¿ and ƒÀ-esterase and aggressiveness. From 61 collected materials, were obtained 19 bacterial isolates, with larger incidence for varieties of human consume than those for industry. Stems from Pato Bragado, Entre Rios do Oeste and Mercedes

  3. Draft Genome Sequence of Pseudomonas syringae pv. syringae ALF3 Isolated from Alfalfa.

    Science.gov (United States)

    Harrison, James; Dornbusch, Melinda R; Samac, Deborah; Studholme, David J

    2016-02-11

    We report here the annotated draft genome sequence of Pseudomonas syringae pv. syringae strain ALF3, isolated in Wyoming. A comparison of this genome sequence with those of closely related strains of P. syringae adapted to other hosts will facilitate research into interactions between this pathogen and alfalfa.

  4. Clavibacter michiganensis subsp. phaseoli subsp. nov., pathogenic in bean.

    Science.gov (United States)

    González, Ana J; Trapiello, Estefanía

    2014-05-01

    A yellow Gram-reaction-positive bacterium isolated from bean seeds (Phaseolus vulgaris L.) was identified as Clavibacter michiganensis by 16S rRNA gene sequencing. Molecular methods were employed in order to identify the subspecies. Such methods included the amplification of specific sequences by PCR, 16S amplified rDNA restriction analysis (ARDRA), RFLP and multilocus sequence analysis as well as the analysis of biochemical and phenotypic traits including API 50CH and API ZYM results. The results showed that strain LPPA 982T did not represent any known subspecies of C. michiganensis. Pathogenicity tests revealed that the strain is a bean pathogen causing a newly identified bacterial disease that we name bacterial bean leaf yellowing. On the basis of these results, strain LPPA 982T is regarded as representing a novel subspecies for which the name Clavibacter michiganensis subsp. phaseoli subsp. nov. is proposed. The type strain is LPPA 982T (=CECT 8144T=LMG 27667T).

  5. Genome Sequences of Two Pseudomonas syringae pv. tomato Race 1 Strains, Isolated from Tomato Fields in California

    OpenAIRE

    Thapa, Shree P.; Coaker, Gitta

    2016-01-01

    Pseudomonas syringae pv. tomato race 1 strains have evolved to overcome genetic resistance in tomato. Here, we present the draft genome sequences of two race 1 P. syringae pv. tomato strains, A9 and 407, isolated from diseased tomato plants in California.

  6. Complete Genome Sequence of Xanthomonas arboricola pv. juglandis 417, a Copper-Resistant Strain Isolated from Juglans regia L.

    Science.gov (United States)

    Pereira, Ulisses P; Gouran, Hossein; Nascimento, Rafael; Adaskaveg, James E; Goulart, Luiz Ricardo; Dandekar, Abhaya M

    2015-01-01

    Here, we report the complete genome sequence of Xanthomonas arboricola pv. juglandis 417, a copper-resistant strain isolated from a blighted walnut fruit (Juglans regia L. cv. Chandler). The genome consists of a single chromosome (5,218 kb).

  7. CHARACTERIZATION OF XANTHOMONAS AXONOPODIS PV. PUNICAE ISOLATES FROM WESTERN MAHARASHTRA AND THEIR SENSITIVITY TO CHEMICAL TREATMENTS

    Directory of Open Access Journals (Sweden)

    K. S. RAGHUWANSHI

    2013-01-01

    Full Text Available Bacterial blight of pomegranate caused by Xanthomonas axonopodis pv. punicae is a major biotic constraint inpeninsular India. Field survey was undertaken in the major pomegranate growing regions of Western Maharashtra,which revealed the high prevalence of bacterial blight incidence in Solapur, Sangli and Nashik districts. Fourdifferent isolates of this pathogen were obtained from the highly infected plant materials collected during the fieldsurvey. X. axonopodis pv. punicae was detected from infected plant material and its identity was confirmed bymorphological, physiological, hypersensitive and pathogenicity tests. Nashik isolate was most virulent. On InterSimple Sequence Repeat (ISSR analysis they formed separate clusters with Akkalkot-Solapur isolate being mostdivergent, while Deola-Nashik and Sangamner-Ahmednagar isolates were most similar. Six chemical treatmentsshowed complete control under in vitro conditions while rest varied in their response to isolates. Completecontrol in all four isolates was observed with Bordeaux mixture (1%; captan (0.25% + Copper oxychloride(0.3%, captan (0.25% + copper hydroxide (0.3%, bromopol (500 ppm + copper oxychloride (0.3%,streptocycline (250 ppm + copper hydroxide (0.3%, streptocycline (500 ppm + copper hydroxide (0.3%during in vitro study

  8. Isolation and Characterization of Bacteriophages Against Pseudomonas syringae pv. actinidiae Causing Bacterial Canker Disease in Kiwifruit.

    Science.gov (United States)

    Yu, Ji-Gang; Lim, Jeong-A; Song, Yu-Rim; Heu, Sunggi; Kim, Gyoung Hee; Koh, Young Jin; Oh, Chang-Sik

    2016-02-01

    Pseudomonas syringae pv. actinidiae causes bacterial canker disease in kiwifruit. Owing to the prohibition of agricultural antibiotic use in major kiwifruit-cultivating countries, alternative methods need to be developed to manage this disease. Bacteriophages are viruses that specifically infect target bacteria and have recently been reconsidered as potential biological control agents for bacterial pathogens owing to their specificity in terms of host range. In this study, we isolated bacteriophages against P. syringae pv. actinidiae from soils collected from kiwifruit orchards in Korea and selected seven bacteriophages for further characterization based on restriction enzyme digestion patterns of genomic DNA. Among the studied bacteriophages, two belong to the Myoviridae family and three belong to the Podoviridae family, based on morphology observed by transmission electron microscopy. The host range of the selected bacteriophages was confirmed using 18 strains of P. syringae pv. actinidiae, including the Psa2 and Psa3 groups, and some were also effective against other P. syringae pathovars. Lytic activity of the selected bacteriophages was sustained in vitro until 80 h, and their activity remained stable up to 50°C, at pH 11, and under UV-B light. These results indicate that the isolated bacteriophages are specific to P. syringae species and are resistant to various environmental factors, implying their potential use in control of bacterial canker disease in kiwifruits.

  9. Molecular Characteristics of Pseudomonas syringae pv. actinidiae Strains Isolated in Korea and a Multiplex PCR Assay for Haplotype Differentiation

    Directory of Open Access Journals (Sweden)

    Hyun Seok Koh

    2014-03-01

    Full Text Available The molecular features of Pseudomonas syringae pv. actinidiae strains isolated in Korea were compared with strains isolated in Japan and Italy. Sequencing of eight P. syringae pv. actinidiae and three P. syringae pv. theae strains revealed a total of 44 single nucleotide polymorphisms across 4,818 bp of the concatenated alignment of nine genes. A multiplex PCR assay was developed for the detection of P. syringae pv. actinidiae and for the specific detection of recent haplotype strains other than strains isolated since the 1980s in Korea. The primer pair, designated as TacF and TacR, specifically amplified a 545-bp fragment with the genomic DNA of new haplotype of P. syringae pv. actinidiae strains. A multiplex PCR conducted with the TacF/TacR primer pair and the universal primer pair for all P. syringae pv. actinidiae strains can be simultaneously applied for the detection of P. syringae pv. actinidiae and for the differentiation of new haplotype strains.

  10. Complete Genome Sequence of Phodopus sungorus Papillomavirus Type 1 (PsPV1), a Novel Member of the Pipapillomavirus Genus, Isolated from a Siberian Hamster.

    Science.gov (United States)

    Kocjan, Boštjan J; Hošnjak, Lea; Račnik, Joško; Zadravec, Marko; Poljak, Mario

    2014-04-10

    We report the complete genomic sequence of Phodopus sungorus papillomavirus type 1 (PsPV1), isolated from an anogenital lesion of a Siberian hamster. PsPV1 is taxonomically classified in the genus Pipapillomavirus and is most closely related to Mesocricetus auratus papillomavirus 1 (MaPV1).

  11. Molecular characterization of Pseudomonas syringae pv. tomato isolates from Tanzania

    DEFF Research Database (Denmark)

    Shenge, K.C.; Stephan, D.; Mabagala, R. B.

    2008-01-01

    . syringae pv. tomato isolates in Tanzania that differ significantly from those used to create the Biolog database. RFLP analysis showed that the isolates were highly conserved in their hrpZ gene. The low level of genomic diversity within the pathogen in Tanzania shows that there is a possibility to use...

  12. Pathotype and genetic diversity amongst Indian isolates of Xanthomonas oryzae pv. oryzae.

    Directory of Open Access Journals (Sweden)

    Deo Mishra

    Full Text Available A number of rice resistance genes, called Xa genes, have been identified that confer resistance against various strains of Xanthomonas oryzae pv. oryzae (Xoo, the causal agent of bacterial blight. An understanding of pathotype diversity within the target pathogen population is required for identifying the Xa genes that are to be deployed for development of resistant rice cultivars. Among 1024 isolates of Xoo collected from 20 different states of India, 11 major pathotypes were distinguished based on their reaction towards ten Xa genes (Xa1, Xa3, Xa4, xa5, Xa7, xa8, Xa10, Xa11, xa13, Xa21. Isolates belonging to pathotype III showing incompatible interaction towards xa8, xa13 and Xa21 and compatible interaction towards the rest of Xa genes formed the most frequent (41% and widely distributed pathotype. The vast majority of the assayed Xoo isolates were incompatible with one or more Xa genes. Exceptionally, the isolates of pathotype XI were virulent on all Xa genes, but have restricted distribution. Considering the individual R-genes, Xa21 appeared as the most broadly effective, conferring resistance against 88 % of the isolates, followed in decreasing order by xa13 (84 %, xa8 (64 %, xa5 (30 %, Xa7 (17 % and Xa4 (14 %. Fifty isolates representing all the eleven pathotypes were analyzed by southern hybridization to determine their genetic relatedness using the IS1112 repeat element of Xoo. Isolates belonging to pathotype XI were the most divergent. The results suggest that one RFLP haplotype that is widely distributed all over India and is represented in strains from five different pathotypes might be an ancestral haplotype. A rice line with xa5, xa13 and Xa21 resistance genes is resistant to all strains, including those belonging to pathotype XI. This three gene combination appears to be the most suitable Xa gene combination to be deployed in Indian rice cultivars.

  13. Effector Diversification Contributes to Xanthomonas oryzae pv. oryzae Phenotypic Adaptation in a Semi-Isolated Environment

    Science.gov (United States)

    Quibod, Ian Lorenzo; Perez-Quintero, Alvaro; Booher, Nicholas J.; Dossa, Gerbert S.; Grande, Genelou; Szurek, Boris; Vera Cruz, Casiana; Bogdanove, Adam J.; Oliva, Ricardo

    2016-01-01

    Understanding the processes that shaped contemporary pathogen populations in agricultural landscapes is quite important to define appropriate management strategies and to support crop improvement efforts. Here, we took advantage of an historical record to examine the adaptation pathway of the rice pathogen Xanthomonas oryzae pv. oryzae (Xoo) in a semi-isolated environment represented in the Philippine archipelago. By comparing genomes of key Xoo groups we showed that modern populations derived from three Asian lineages. We also showed that diversification of virulence factors occurred within each lineage, most likely driven by host adaptation, and it was essential to shape contemporary pathogen races. This finding is particularly important because it expands our understanding of pathogen adaptation to modern agriculture. PMID:27667260

  14. In vitro antimicrobial activity of aqueous extracts from Lentinula edodes isolates against Colletotrichum sublineolum and Xanthomonas axonopodis pv. Passiflorae

    Directory of Open Access Journals (Sweden)

    Nivea Maria Tonucci-Zanardo

    2015-03-01

    Full Text Available The aim of this study was to evaluate the antimicrobial activity of aqueous extracts from fruiting bodies of different isolates of Lentinula edodes on the pathogens Colletotrichum sublineolum, the causal agent of anthracnose in sorghum, and Xanthomonas axonopodis pv. passiflorae, the causal agent of bacterial spot in passion fruit. Results showed that the aqueous extracts from isolates LE JAB-K and LE 95/01 significantly reduced C. sublineolum spore germination, while the isolate LE 96/22 was the only one to inhibit the pathogen mycelial growth. However, all L. edodes isolates showed inhibitory effect on C. sublineolum appressorium formation. Regarding X. axonopodis pv. passiflorae, the aqueous extracts from all L. edodes isolates significantly reduced the in vitro multiplication of the bacterium. However, antimicrobial activity was lost when the extracts were autoclaved, demonstrating their thermolabile property. The aqueous extract from isolate LE 96/22 was also partially purified by anion exchange chromatography and fraction V exhibited high inhibitory activity on the in vitro mycelial growth of C. sublineolum, while the multiplication of X. axonopodis pv. passiflorae was inhibited by fractions IV, V and VII. Thus, L. edodes isolates were shown to produce compounds exhibiting antifungal and antibacterial activities against phytopathogens, which are mainly concentrated in fraction V.

  15. Xanthomonas oryzae pv oryzae the Causal Agent of Bacterial Leaf Blight of rice: Isolation, Characterization, and Study of Transposon Mutagenesis

    Directory of Open Access Journals (Sweden)

    Abdjad Asih Nawangsih

    2011-04-01

    Full Text Available Xanthomonas oryzae pv oryzae the Causal Agent of Bacterial Leaf Blight of rice: Isolation, Characterization, and Study of Transposon Mutagenesis. X. oryzae pv. oryzae (Xoo causes bacterial leaf blight (BLB of rice (Oryza sativa L., a major disease that constrains production of the staple crop in many countries of the world. Identification of X. oryzae pv. oryzae (Xoo was conducted based on the disease symptoms, pathogenicity, morphological, physiological, and genetic characteristics of bacterial cultures isolated from the infected plants. Fifty bacterial isolates predicted as Xoo have been successfully isolated. They are aerobic, rod shaped, and Gram negative bacteria. The isolates were evaluated for their hypersensitivity in tobacco and pathogenicity in rice plant. Fifty isolates induced hypersensitive reaction in tobacco and showed pathogenicity symptom in rice in different length. Based on physiological test, hypersensitivity and pathogenicity reactions, three bacterial isolates strongly predicted as Xoo, i.e. STG21, STG42, and STG46, were non indole formation, non pigment fluorescent, hydrolyzed casein, catalase activity positive, but negative oxidase. Partial sequencing of 16S rRNA genes of STG21 and STG42 showed 80% and 82% homology with X. oryzae, respectively, while STG46 showed 84% homology with X. campestris. Mini-Tn5 transposon mutagenesis of STG21 generated one of the mutants (M5 lossed it’s ability to induce hypersensitive reaction in tobacco plant and deficient in pathogenicity on rice. The lesion length of rice leaf caused by the mutant M5 decreased up to 80%.

  16. Erwinia oleae sp. nov., isolated from olive knots caused by Pseudomonas savastanoi pv. savastanoi.

    Science.gov (United States)

    Moretti, Chiaraluce; Hosni, Taha; Vandemeulebroecke, Katrien; Brady, Carrie; De Vos, Paul; Buonaurio, Roberto; Cleenwerck, Ilse

    2011-11-01

    Three endophytic bacterial isolates were obtained in Italy from olive knots caused by Pseudomonas savastanoi pv. savastanoi. Phenotypic tests in combination with 16S rRNA gene sequence analysis indicated a phylogenetic position for these isolates in the genera Erwinia or Pantoea, and revealed two other strains with highly similar 16S rRNA gene sequences (>99 %), CECT 5262 and CECT 5264, obtained in Spain from olive knots. Rep-PCR DNA fingerprinting of the five strains from olive knots with BOX, ERIC and REP primers revealed three groups of profiles that were highly similar to each other. Multilocus sequence analysis (MLSA) based on concatenated partial atpD, gyrB, infB and rpoB gene sequences indicated that the strains constituted a single novel species in the genus Erwinia. The strains showed general phenotypic characteristics typical of the genus Erwinia and whole genome DNA-DNA hybridization data confirmed that they represented a single novel species of the genus Erwinia. The strains showed DNA G+C contents ranging from 54.7 to 54.9 mol%. They could be discriminated from phylogenetically related species of the genus Erwinia by their ability to utilize potassium gluconate, l-rhamnose and d-arabitol, but not glycerol, inositol or d-sorbitol. The name Erwinia oleae sp. nov. (type strain DAPP-PG 531(T)= LMG 25322(T) = DSM 23398(T)) is proposed for this novel taxon.

  17. Introduction of the Escherichia coli gdhA gene into Rhizobium phaseoli: effect on nitrogen fixation.

    Science.gov (United States)

    Bravo, A; Becerril, B; Mora, J

    1988-01-01

    Rhizobium phaseoli lacks glutamate dehydrogenase (GDH) and assimilates ammonium by the glutamine synthetase-glutamate synthase pathway. A strain of R. phaseoli harboring the Escherichia coli GDH structural gene (gdhA) was constructed. GDH activity was expressed in R. phaseoli in the free-living state and in symbiosis. Nodules with bacteroids that expressed GDH activity had severe impairment of nitrogen fixation. Also, R. phaseoli cells that lost GDH activity and assimilated ammonium by the glutamine synthetase-glutamate synthase pathway preferentially nodulated Phaseolus vulgaris. PMID:2892830

  18. a -Difluoromethylornithine Inhibits the Growth of Fungus Macrophomina phaseoli

    OpenAIRE

    PALAVAN-ÜNSAL, Narçin

    2014-01-01

    a -Difluoromethylornithine (DFMO), a specific enzyme activated inhibitor of ornithine decarboxylase (ODC), significantly inhibited the mycelial growth of the fungus Macrophomina phaseoli (Tassi) Goidanich. Putrescine (Put), when added to the nutrient medium at a concentration of 0.25 mM, decreased the inhibitory effect of DFMO. These results suggest that polyamines (PAs) are essential for the growth of fungi and that DFMO is applicable to the alleviation or prevention of crop losses due to ph...

  19. High Efficiency Non-isolated Three Port DC-DC Converter for PV-Battery Systems

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Anthon, Alexander; Zhang, Zhe

    2016-01-01

    This paper presents a nonisolated Three Port Converter (TPC) with a unidirectional port for photovoltaic (PV) panels and a bidirectional port for energy storage. With the proposed topology single power conversion is performed between each port, so high efficiencies are obtained. A theoretical...

  20. High Efficiency Non-isolated Three Port DC-DC Converter for PV-Battery Systems

    DEFF Research Database (Denmark)

    Tomas Manez, Kevin; Anthon, Alexander; Zhang, Zhe;

    2016-01-01

    This paper presents a nonisolated Three Port Converter (TPC) with a unidirectional port for photovoltaic (PV) panels and a bidirectional port for energy storage. With the proposed topology single power conversion is performed between each port, so high efficiencies are obtained. A theoretical ana...

  1. Development of a New Semiselective Medium for Isolating Xanthomonas campestris pv. manihotis from Plant Material and Soil.

    Science.gov (United States)

    Fessehaie, A; Wydra, K; Rudolph, K

    1999-07-01

    ABSTRACT An effective control for bacterial blight of cassava (Manihot esculenta), caused by Xanthomonas campestris pv. manihotis, requires the use of non-contaminated cuttings and seeds. Using classical agar plating techniques for screening planting material for contamination has not been very successful because of the lack of a reliable semiselective agar medium. The pathogen grows slowly on general plating media and is easily overgrown by saprophytic bacteria during isolation from diseased plants. In an effort to develop a semiselective medium, the utilization of several carbon and nitrogen sources was studied. Results of these tests provided information used to design a basal medium allowing good growth of the target organism while suppressing growth of several common saprophytes. Additional selectivity was achieved by incorporating three antibiotics into the basal medium. The new semiselective agar medium, designated cefazolin trehalose agar (CTA) medium, contained (per liter) 3.0 g of K(2)HPO(4), 1.0 g of NaH(2)PO(4), 0.3 g of MgSO(4).7H(2)O, 1.0 g of NH(4)Cl, 9.0 g of D(+)-trehalose, 1.0 D(+)-glucose, 1.0 g of yeast extract, 0.025 g of cefazolin, 0.0012 g of lincomycin, 0.0025 g of phosphomycin, 0.25 g of cycloheximide, and 14.0 g of agar. In comparison to a starch-based semiselective medium (SXM), plating efficiencies using pure cultures of 10 strains of X. campestris pv. manihotis were significantly higher on CTA, with an average of 85 and 50%, respectively. Likewise, isolation and recovery of X. campestris pv. manihotis from infected cassava leaves and contaminated soil were much higher on CTA than on SXM agar. When X. campestris pv. manihotis occurs in high concentrations in diseased tissue, the standard yeast trehalose glucose agar medium supplemented with 250 mug of cycloheximide per ml appears to be satisfactory. The newly developed CTA medium should prove useful for control strategies to identify and remove infected planting material of cassava, as

  2. Classification of physiological races of Fusarium oxysporum f. sp. phaseoli in common bean

    Directory of Open Access Journals (Sweden)

    Francisco Humberto Henrique

    2015-03-01

    Full Text Available Fusarium wilt, caused by Fusarium oxysporum Schlecht. f. phaseoli Kendrick and Snyder (FOP, is a major disease of common bean, causing large economic losses. Genetic resistance is one of the main mechanisms of pathogen control, and knowledge of the physiological variability is fundamental in breeding for resistant cultivars. Thus, a method of pathogen classification that describes the variability and is useful in plant breeding of isolates from different sources was evaluated by different methodologies. Common bean plants of different sets of differentiating cultivars were inoculated with 25 FOP isolates and 3 controls, totaling 28 isolates evaluated 30 days after inoculation. The variability in the isolates found in this study differs from the results of other authors, who reported a small number of physiological races of the pathogen and disagrees with their evaluation of the races and the evaluation methodology. The proposed approach for binary classification based on a group of 12 differentiating cultivars demonstrated that the variability in pathogenicity of FOP is greater than reported so far. By this methodology, 27 different physiological races of the pathogen were obtained. The methods led to contrasting results, with double race classification in the same isolate. The physiological variability found indicates that the physiological races of the pathogen are not limited to 7 as previously mentioned.

  3. Isolation and characterization of bacteriophages infecting Xanthomonas arboricola pv. juglandis, the causal agent of walnut blight disease.

    Science.gov (United States)

    Romero-Suarez, Sandra; Jordan, Brian; Heinemann, Jack A

    2012-05-01

    Walnut orchards suffer from a blight caused by the bacteria Xanthomonas arboricola pv. juglandis. These bacteria can be infected by viral bacteriophages and this study was carried out to isolate and characterize bacteriophages from walnut orchards located throughout the South Island of New Zealand. Twenty six X. arboricola phages were isolated from three hundred and twenty six samples of plant material representing phyllosphere and rhizosphere ecosystems. The phage isolates were characterized by host-range, plaque and particle morphology, restriction digest and phylogenetic analysis and stability under various storage conditions. From capsid and tail dimensions the bacteriophages were considered to belong to the double-stranded DNA families Podoviridae and Siphoviridae. Of the twenty six bacteriophages, sixteen belonged to Podoviridae and were found both in the phyllosphere and rhizosphere. In contrast, Siphoviridae were present only in the rhizosphere isolates. Phage genome sizes ranged from 38.0 to 52.0 kb from a Hind III restriction digestion and had in common a 400 kb fragment that was identical at the DNA level. Despite the similar restriction patterns, maximum parsimony bootstrap analysis showed that the phage were members of different groups. Finally, we hypothesise that these phage might have use in a biocontrol strategy and therefore storage stability and efficacy was tested. Titres declined more than 50% over a 12-months storage period. Deep-freezing temperatures (-34°C) increased while chloroform decreased the stability.

  4. Integrated sizing and scheduling of wind/PV/diesel/battery isolated systems

    KAUST Repository

    Malheiro, André

    2015-05-22

    In this paper we address the optimal sizing and scheduling of isolated hybrid systems using an optimization framework. The hybrid system features wind and photovoltaic conversion systems, batteries and diesel backup generators to supply electricity demand. A Mixed-Integer Linear Programming formulation is used to model system behavior over a time horizon of one year, considering hourly changes in both the availability of renewable resources and energy demand. The optimal solution is achieved with respect to the minimization of the levelized cost of energy (LCOE) over a lifetime of 20 years. Results for a case study show that the most economical solution features all four postulated subsystems. © 2015 Elsevier Ltd.

  5. Pseudomonas syringae pv. actinidiae (PSA isolates from recent bacterial canker of kiwifruit outbreaks belong to the same genetic lineage.

    Directory of Open Access Journals (Sweden)

    Angelo Mazzaglia

    Full Text Available Intercontinental spread of emerging plant diseases is one of the most serious threats to world agriculture. One emerging disease is bacterial canker of kiwi fruit (Actinidia deliciosa and A. chinensis caused by Pseudomonas syringae pv. actinidiae (PSA. The disease first occurred in China and Japan in the 1980s and in Korea and Italy in the 1990s. A more severe form of the disease broke out in Italy in 2008 and in additional countries in 2010 and 2011 threatening the viability of the global kiwi fruit industry. To start investigating the source and routes of international transmission of PSA, genomes of strains from China (the country of origin of the genus Actinidia, Japan, Korea, Italy and Portugal have been sequenced. Strains from China, Italy, and Portugal have been found to belong to the same clonal lineage with only 6 single nucleotide polymorphisms (SNPs in 3,453,192 bp and one genomic island distinguishing the Chinese strains from the European strains. Not more than two SNPs distinguish each of the Italian and Portuguese strains from each other. The Japanese and Korean strains belong to a separate genetic lineage as previously reported. Analysis of additional European isolates and of New Zealand isolates exploiting genome-derived markers showed that these strains belong to the same lineage as the Italian and Chinese strains. Interestingly, the analyzed New Zealand strains are identical to European strains at the tested SNP loci but test positive for the genomic island present in the sequenced Chinese strains and negative for the genomic island present in the European strains. Results are interpreted in regard to the possible direction of movement of the pathogen between countries and suggest a possible Chinese origin of the European and New Zealand outbreaks.

  6. Interaction of Acidithiobacillus ferrooxidans, Rhizobium phaseoli and Rhodotorula sp. in bioleaching process based on Lotka–Volterra model

    Directory of Open Access Journals (Sweden)

    Xuecheng Zheng

    2016-07-01

    Conclusion: The relationship among microorganisms during leaching could be described appropriately by Lotka–Volterra model between the initial and peak values. The relationship of A. ferrooxidans and R. phaseoli could be considered as mutualism, whereas, the relationship of A. ferrooxidans and R. phaseoli could be considered as commensalism.

  7. Pathogenicity of Macrophomina phaseoli on Jute in the Presence of Meloidogyne incognita and Hoplolaimus indicus.

    Science.gov (United States)

    Haque, M D; Mukhopadhyaya, M C

    1979-10-01

    Seedlings of Corchorus capsularis (cv. C4444) were inoculated with Meloidogyne incognita, Hoplolaimus indicus, and a fungus pathogen of jute, Macrophomina phaseoli, separately and in all possible combinations. The significant damage of jute plants caused individually by the pathogens was aggravated when the fungus was associated with either of the nematode species. M. incognita alone caused greater damage than either H. indicus or Macrophomina phaseoli alone. Plants inoculated with M. incognita and Macrophomina phaseoli were more severely damaged than plants inoculated with H. indicus and the fungus. Plant growth was minimum and disease symptoms were maximum when all pathogens acted together. In the presence of the fungus, M. incognita produced fewer galls. The reproduction of H. indicus was not influenced by the other organisms.

  8. Infestation of Caliothrips phaseoli (Thysanoptera: Thripidae) on Bean Cultivars Grown in the Winter, Rainy, and Dry Seasons in Brazil.

    Science.gov (United States)

    Boiça Júnior, Arlindo Leal; Costa, Eduardo Neves; De Souza, Bruno Henrique Sardinha; Da Silva, Anderson Gonçalves; Chiorato, Alisson Fernando

    2015-08-01

    The present study aimed to identify common bean (Phaseolus vulgaris L.) cultivars less susceptible to Caliothrips phaseoli (Hood) in different growing seasons, to evaluate whether climatic conditions influence plant resistance to C. phaseoli infestation, and to investigate the preferred plant part for insect feeding. Eighteen common bean cultivars were evaluated in the winter season, and 19 cultivars were assessed in the rainy and dry seasons, under field conditions in the municipality of Jaboticabal, state of São Paulo, Brazil. Infestation of C. phaseoli nymphs in the upper and lower parts of the beans plants was recorded at weekly intervals from 25 days after plant emergence (DAE) to 60 DAE. In the winter season, the cultivars 'IAC Galante,' 'IAC Centauro,' 'IAC Carioca Eté,' and 'IAC Formoso' had significantly lower number of thrips than the cultivar 'IAC Diplomata.' In the rainy season, the cultivars 'IAC Harmonia' and 'IPR Siriri' had the lowest thrips infestation, differing from the cultivars 'BRS Pontal' and 'IAC Una.' The bean cultivars were equally susceptible to C. phaseoli in the dry season. The results suggest that C. phaseoli nymphs prefer to infest leaves of the lower part of bean plants, like most generalist herbivorous insects. In the winter and dry seasons, the highest thrips infestation was observed at 60 DAE, while in the rainy season, it was recorded from 32 to 46 DAE. Overall, C. phaseoli infestation on bean cultivars was not influenced by either temperature, relative humidity, or rainfall.

  9. Effect of Naturally Occurring nif Reiterations on Symbiotic Effectiveness in Rhizobium phaseoli

    Science.gov (United States)

    Romero, David; Singleton, Paul W.; Segovia, Lorenzo; Morett, Enrique; Bohlool, B. Ben; Palacios, Rafael; Dávila, Guillermo

    1988-01-01

    Most naturally occurring strains of Rhizobium phaseoli possess reiteration of the nif genes. Three regions contain nitrogenase structural genes in strain CFN42. Two of these regions (a and b) have copies of nifH, nifD, and nifK, whereas the third region (c) contains only nifH. Strains containing mutations in either nif region a or nif region b had significantly diminished symbiotic effectiveness compared with the wild-type strain on the basis of nodule mass, total nitrogenase activity per plant, nitrogenase specific activity, total nitrogen in the shoot, and percentage of nitrogen. A strain containing mutations in both nif region a and nif region b was totally ineffective. These data indicate that both nif region a and nif region b are needed for full symbiotic effectiveness in R. phaseoli. PMID:16347593

  10. Interaction of Meloidogyne javanica and Macrophomina phaseoli in Kenaf Root Rot.

    Science.gov (United States)

    Tu, C C; Cheng, Y H

    1971-01-01

    Incidence and severity of root-rot caused by the fungus Macrophomina phaseoli was increased in screenhouse-grown kenaf (Hibiscus cannabinus L.) seedlings simultaneously infected by the nematode Meloidogyne javanica. In seedlings inoculated at 5, 10 and 15 days of age, root rot lesions increased 70.3, 44.1 and 21.8%, and nematode penetration increased 49.0, 36.7, and 12.3% when both fungus and nematode were present.

  11. Analysis of outer membrane vesicle associated proteins isolated from the plant pathogenic bacterium Xanthomonas campestris pv. campestris

    Directory of Open Access Journals (Sweden)

    Niehaus Karsten

    2008-06-01

    Full Text Available Abstract Background Outer membrane vesicles (OMVs are released from the outer membrane of many Gram-negative bacteria. These extracellular compartments are known to transport compounds involved in cell-cell signalling as well as virulence associated proteins, e.g. the cytolysine from enterotoxic E. coli. Results We have demonstrated that Xanthomonas campestris pv. campestris (Xcc releases OMVs into the culture supernatant during growth. A proteome study identified 31 different proteins that associate with the OMV fraction of which half are virulence-associated. A comparison with the most abundant outer membrane (OM proteins revealed that some proteins are enriched in the OMV fraction. This may be connected to differences in the LPS composition between the OMVs and the OM. Furthermore, a comparison of the OMV proteomes from two different culture media indicated that the culture conditions have an impact on the protein composition. Interestingly, the proteins that are common to both culture conditions are mainly involved in virulence. Conclusion Outer membrane vesicles released from the OM of Xcc contain membrane- and virulence-associated proteins. Future experiments will prove whether these structures can serve as "vehicles" for the transport of virulence factors into the host membrane.

  12. Analysis of outer membrane vesicle associated proteins isolated from the plant pathogenic bacterium Xanthomonas campestris pv. campestris.

    Science.gov (United States)

    Sidhu, Vishaldeep K; Vorhölter, Frank-Jörg; Niehaus, Karsten; Watt, Steven A

    2008-06-02

    Outer membrane vesicles (OMVs) are released from the outer membrane of many Gram-negative bacteria. These extracellular compartments are known to transport compounds involved in cell-cell signalling as well as virulence associated proteins, e.g. the cytolysine from enterotoxic E. coli. We have demonstrated that Xanthomonas campestris pv. campestris (Xcc) releases OMVs into the culture supernatant during growth. A proteome study identified 31 different proteins that associate with the OMV fraction of which half are virulence-associated. A comparison with the most abundant outer membrane (OM) proteins revealed that some proteins are enriched in the OMV fraction. This may be connected to differences in the LPS composition between the OMVs and the OM. Furthermore, a comparison of the OMV proteomes from two different culture media indicated that the culture conditions have an impact on the protein composition. Interestingly, the proteins that are common to both culture conditions are mainly involved in virulence. Outer membrane vesicles released from the OM of Xcc contain membrane- and virulence-associated proteins. Future experiments will prove whether these structures can serve as "vehicles" for the transport of virulence factors into the host membrane.

  13. Ultrastructural aspects in perithecia hyphae septal pores of Glomerella cingulata F. SP. Phaseoli

    Directory of Open Access Journals (Sweden)

    Roca M. María Gabriela

    2000-01-01

    Full Text Available Glomerella cingulata (Stonem. Spauld. & Schrenk f. sp. phaseoli, better known in its anamorphic state Colletotrichum lindemuthianum (Sacc. & Magn. Briosi & Cav., is a causal agent of anthracnose in beans (Phaseolus vulgaris L.. Ultrastructural aspects of the perithecial hyphae of this pathogen were studied. The perithecia hyphae septal pores were found either plugged by a vesicle or unplugged. Some perithecia hyphae septa presented no pore. The Woronin bodies, close to the septal pores, appeared as globose structures which were more electron dense than the occlusions plugging the septal pore.

  14. Two cases of delayed cardiac tamponade due to pericarditis after pulmonary vein (PV) isolation for atrial fibrillation.

    Science.gov (United States)

    Torihashi, Sadayoshi; Shiraishi, Hirokazu; Hamaoka, Tetsuro; Imai, Mikimasa; Kuroyanagi, Akira; Nakanishi, Naohiko; Nakamura, Takeshi; Yamano, Tetsuhiro; Matsumuro, Akiyoshi; Shirayama, Takeshi

    2015-01-01

    Catheter ablation is an established treatment for atrial fibrillation (AF). The incidence of major complications related to the procedure is reported to be 4.5%, and delayed cardiac tamponade (DCT) is a rare, although recently recognized, complication. However, the mechanisms underlying the development of DCT remain unclear. We herein report the cases of two men, both 49 years of age, who developed cardiac tamponade requiring pericardiocentesis a few weeks after undergoing pulmonary vein isolation for persistent AF. Physicians should explain to the patient the potential for DCT as a complication prior to performing catheter ablation and provide careful follow-up for at least a few weeks after the session.

  15. 'Tropicalisation' of feed-in tariffs. A custom-made support scheme for hybrid PV/diesel systems in isolated regions

    Energy Technology Data Exchange (ETDEWEB)

    Solano-Peralta, Mauricio; Van Sark, Wilfried G.J.H.M. [Department of Science, Technology and Society, Copernicus Institute for Sustainable Development and Innovation, Utrecht University, Heidelberglaan 2, 3584 CS Utrecht (Netherlands); Moner-Girona, Magda [Renewable Energies Unit, Institute for Energy, European Commission-Joint Research Centre, Via E. Fermi 2749 - TP 450 I-21027 Ispra (Italy); Vallve, Xavier [Trama Tecnoambiental, Ripolles 46, 08026 Barcelona (Spain)

    2009-12-15

    The interest and actions towards introducing renewables for off-grid regions has increased due to their ostensible cost-effectiveness, eco-friendliness and quality services provided. Nevertheless, in many isolated areas diesel generators appear as a common option, confirming that there is a need for financial support mechanisms that aid the introduction of renewables due to their higher initial investment costs. This paper proposes a so-called 'tropicalisation' of the Feed-in Tariff scheme to promote the introduction of hybrid systems in isolated communities based on the idea of awarding for each kWh produced by renewable energies a premium value during a guaranteed period of time. The proposed Renewable Energy Premium Tariff (RPT) scheme is an alternative mechanism to the usual initial investment donation for off-grid energy development projects by recognising the production of renewable electricity and opting for a long-term sustainability of the projects. Ecuador presents ideal conditions to study the introduction of such a 'tropicalised' scheme since a Feed-in Law including off-grid projects was established in 2002 and since there are governmental and local efforts for the introduction of renewable hybrids in isolated regions. Modelling of the introduction of photovoltaics (PVs) into diesel systems for several mini-grids located in isolated regions of Ecuador has been performed, and included a detailed financial analysis for optimisation of RPT values and a comparison with existing stand-alone diesel systems. The results show the cost-effectiveness of PV/diesel hybrids over diesel gensets, taking into account present and future diesel prices. To obtain long-term sustainability of the project, the RPT values are set at 0.70-1.20$kWh covering the operability of the whole system for 20 years, where the renewable fraction should have the largest share in the hybrid system. The proposed mechanism is expected to aid the introduction of renewable

  16. A DNA-Based Procedure for In Planta Detection of Fusarium oxysporum f. sp. phaseoli.

    Science.gov (United States)

    Alves-Santos, Fernando M; Ramos, Brisa; García-Sánchez, M Asunción; Eslava, Arturo P; Díaz-Mínguez, José María

    2002-03-01

    ABSTRACT We have characterized strains of Fusarium oxysporum from common bean fields in Spain that were nonpathogenic on common bean, as well as F. oxysporum strains (F. oxysporum f. sp. phaseoli) pathogenic to common bean by random amplified polymorphic DNA (RAPD) analysis. We identified a RAPD marker (RAPD 4.12) specific for the highly virulent pathogenic strains of the seven races of F. oxysporum f. sp. phaseoli. Sequence analysis of RAPD 4.12 allowed the design of oligonucleotides that amplify a 609-bp sequence characterized amplified region (SCAR) marker (SCAR-B310A280). Under controlled environmental and greenhouse conditions, detection of the pathogen by polymerase chain reaction was 100% successful in root samples of infected but still symptomless plants and in stem samples of plants with disease severity of >/=4 in the Centro Internacional de Agricultura Tropical (CIAT; Cali, Colombia) scale. The diagnostic procedure can be completed in 5 h and allows the detection of all known races of the pathogen in plant samples at early stages of the disease with no visible symptoms.

  17. Interacción de Tsukamurella paurometabola C-924 con Rhizobium leguminosarum biovar phaseoli CFH en el cultivo de frijol

    Directory of Open Access Journals (Sweden)

    Marieta Marín Bruzos

    2013-01-01

    Full Text Available En el estudio se evaluaron, mediante análisis de los parámetros fenológicos de las plantas, la interacción de Tsukamurella paurometabola C-924 con Rhizobium leguminosarum biovar phaseoli CFH en el cultivo de frijol. Se emplearon cuatro tratamientos: plantas sin inocular (control, inoculadas con T. paurometabola C-924, inoculadas con R. leguminosarum biovar phaseoli CFH e inoculadas con ambas cepas. Se observaron diferencias significativas (P < 0.01 en los porcentajes de germinación de las plantas tratadas con microorganismos de forma independiente o conjunta con respecto al control sin inocular. Se determinó que la inoculación de T. paurometabola C-924 afectó el proceso de nodulación de R. leguminosarum biovar phaseoli CFH. Sin embargo, esto no incidió de manera significativa en la altura de las plantas ni en el diámetro del tallo, ya que no se encontraron diferencias entre los tratamientos para estos parámetros. Para el número de hojas, los mejores resultados se obtuvieron con la aplicación de T. paurometabola C-924. Se concluyó que la interacción de T. paurometabola C-924 con R. leguminosarum biovar phaseoli CFH en el frijol estimuló significativamente la germinación de las semillas y el número de hojas de las plantas con respecto al control sin inocular. Aunque la aplicación de T. paurometabola C-924 no favoreció la nodulación de R. leguminosarum biovar phaseoli CFH, esto no afectó las características fenológicas del cultivo.

  18. Autonomous cascaded PV system

    OpenAIRE

    2011-01-01

    This paper proposes multi-level PV system; three PV generators each coupled to a buck cell. Each PV-generator-buckconverter channel is controlled such that maximum power is captured independently under different irradiation and temperature levels. The system operation under normal/abnormal conditions is investigated by thoroughly mathematical and simulation work. Peer Reviewed

  19. Flexible packaging for PV modules

    Science.gov (United States)

    Dhere, Neelkanth G.

    2008-08-01

    Economic, flexible packages that provide needed level of protection to organic and some other PV cells over >25-years have not yet been developed. However, flexible packaging is essential in niche large-scale applications. Typical configuration used in flexible photovoltaic (PV) module packaging is transparent frontsheet/encapsulant/PV cells/flexible substrate. Besides flexibility of various components, the solder bonds should also be flexible and resistant to fatigue due to cyclic loading. Flexible front sheets should provide optical transparency, mechanical protection, scratch resistance, dielectric isolation, water resistance, UV stability and adhesion to encapsulant. Examples are Tefzel, Tedlar and Silicone. Dirt can get embedded in soft layers such as silicone and obscure light. Water vapor transmittance rate (WVTR) of polymer films used in the food packaging industry as moisture barriers are ~0.05 g/(m2.day) under ambient conditions. In comparison, light emitting diodes employ packaging components that have WVTR of ~10-6 g/(m2.day). WVTR of polymer sheets can be improved by coating them with dense inorganic/organic multilayers. Ethylene vinyl acetate, an amorphous copolymer used predominantly by the PV industry has very high O2 and H2O diffusivity. Quaternary carbon chains (such as acetate) in a polymer lead to cleavage and loss of adhesional strength at relatively low exposures. Reactivity of PV module components increases in presence of O2 and H2O. Adhesional strength degrades due to the breakdown of structure of polymer by reactive, free radicals formed by high-energy radiation. Free radical formation in polymers is reduced when the aromatic rings are attached at regular intervals. This paper will review flexible packaging for PV modules.

  20. Fire resistant PV shingle assembly

    Science.gov (United States)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  1. Analysis of Kenyan isolates of Fusarium solani f. sp. phaseoli from ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-06-03

    Jun 3, 2008 ... were determined by visual observation while pigmentation on the mycelium was determined with ..... pathogenicity, a correlation analysis was done using the computer .... death syndrome (SDS) on soybean foliage, a disease.

  2. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault.......Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  3. Selectable genes for transformation of the fungal plant pathogen Glomerella cingulata f. sp. phaseoli (Colletotrichum lindemuthianum).

    Science.gov (United States)

    Rodriguez, R J; Yoder, O C

    1987-01-01

    Glomerella cingulata f. sp. phaseoli (Gcp) was transformed using either of two selectable markers: the amdS + gene of Aspergillus nidulans, which encodes acetamidase and permits growth on acetamide as the sole nitrogen source and the hygBR gene of Escherichia coli which encodes hygromycin B (Hy) phosphotransferase and permits growth in the presence of the antibiotic Hy. The amdS+ gene functioned in Gcp under control of A. nidulans regulatory signals and hygBR was expressed after fusion to a promoter from Cochliobolus heterostrophus, another filamentous ascomycete. Protoplasts to be transformed were generated with the digestive enzyme complex Novozym 234 and then were exposed to plasmid DNA in the presence of 10 mM CaCl2 and polyethylene glycol. Transformation occurred by integration of single or multiple copies of either the amdS+ or hygBR plasmid into the fungal genome. There was no evidence of autonomous plasmid replication. Transformants were mitotically stable on selective and nonselective media. However, transforming DNA in hygBR transformants was observed to occasionally rearrange during nonselective growth, resulting in fewer copies of the plasmid per genome. These transformants were capable of infecting bean (Phaseolus vulgaris), the Gcp host plant, and after recovery from infected tissue were found to have retained both the transforming DNA unrearranged in their genomes and the Hy resistance phenotype. All single-conidial cultures derived from both amdS+ and hygBR transformants had the transplanted phenotype, suggesting that transformants were homokaryons.

  4. Reação de linhagens de feijoeiro ao fungo Fusarium oxysporum f. sp. phaseoli em condições controladas Reaction of common bean lines to Fusarium oxysporum f. sp. phaseoli in controlled conditions

    Directory of Open Access Journals (Sweden)

    Mônica Juliani Zavaglia Pereira

    2011-10-01

    Full Text Available Entre os patógenos que mais contribuem para a redução da produtividade do feijoeiro no Brasil está o Fusarium oxysporum f. sp. phaseoli. O emprego de cultivares resistentes é o controle mais eficaz para esse patógeno. Conduziu-se este trabalho, com o objetivo de avaliar linhagens de feijoeiro (Phaseolus vulgaris L. do banco de germoplasma da Universidade Federal de Lavras (UFLA, quanto a reação ao Fusarium oxysporum f. sp. phaseoli e, ao mesmo tempo, estimar os parâmetros genéticos e fenotípicos que possam auxiliar em futuros programas de melhoramento para esse caráter. Foram avaliadas 367 linhagens em dez experimentos. As testemunhas 'Carioca' (suscetível e 'Carioca MG' (resistente foram utilizadas em todos os experimentos. O delineamento utilizado foi inteiramente ao acaso, com cinco repetições e parcelas de uma planta por vaso. As inoculações foram realizadas segundo a metodologia de corte e imersão de raízes na suspensão de esporos do fungo e as avaliações realizadas aos 21 dias após a inoculação com base no índice de severidade da doença empregando-se notas de 1 (plantas sem sintomas a 9 (plantas mortas.Das linhagens do banco de germoplasma da Universidade Federal de Lavras (UFLA avaliadas, 36,5% foram resistentes ao Fusarium oxysporum f. sp. phaseoli. Entre as resistentes, a maioria foi linhagens obtidas antes de 1990. Das 18 linhagens dos experimentos de VCU, do período de 2005/06, apenas quatro foram suscetíveis. A estimativa da herdabilidade (h² foi elevada (h² = 87%, indicando que, a princípio, o caráter é de fácil seleção.Among the pathogens that most contribute for reducing the productivity of beans in Brazil is the Fusarium oxysporum f. sp. phaseoli. The use of resistant cultivars is the most effective control for this pathogen. The aim of this study was to evaluate germoplasm bean (Phaseolus vulgaris L. lines of the Federal University of Lavras (UFLA as the reaction to the Fusarium oxysporum f

  5. Variability of isolated colonies in bean nodulating Rhizobium strains before and after exposure to high temperature

    Directory of Open Access Journals (Sweden)

    Raposeiras Rui

    2002-01-01

    Full Text Available Irregular response to bean plants to Rhizobium inoculation has been attributed to among other factors, low competitive ability, low N2 fixation efficiency and genetic instability of the symbiont. This genetic instability caused by high rates of genomic rearrangements and/or plasmid deletions can be accentuated by high temperatures. This fact may limit the utilization of these strains as inoculants, especially in tropical soils. In this study, the variability of isolated colonies derived from effective R. leguminosarum bv. phaseoli (SLP1.3 and BR 10.026 and R tropici (SLA2.2 and BR322 strains was evaluated before and after exposure to high temperatures (four consecutive thermal shocks at 45masculineC. This evaluation involved plant dry matter analysis of inoculated plants and genotypic (plasmid profile and genomic patterns via RAPD analysis of the Rhizobium strains. The results evidenced that high temperature improve the natural performance variability especially between isolated colonies from R. leguminosarum bv. phaseoli strains. The plasmid profile of isolated colonies from R. tropici strains were identical regardless of temperature treatment whereas isolated colonies from R. leguminosarum bv. phaseoli alterations were detected especially after the thermal treatment. The genomic patterns generated by AP-PCR showed more alterations and genetic variation in isolated colonies from R. leguminosarum bv. phaseoli strains indicating that R. tropici strains are more stable and lower affected by high temperature.

  6. Fuzzy-PI-based centralised control of semi-isolated FP-SEPIC/ZETA BDC in a PV/battery hybrid system

    Science.gov (United States)

    Mahendran, Venmathi; Ramabadran, Ramaprabha

    2016-11-01

    Multiport converters with centralised controller have been most commonly used in stand-alone photovoltaic (PV)/battery hybrid system to supply the load smoothly without any disturbances. This study presents the performance analysis of four-port SEPIC/ZETA bidirectional converter (FP-SEPIC/ZETA BDC) using various types of centralised control schemes like Fuzzy tuned proportional integral controller (Fuzzy-PI), fuzzy logic controller (FLC) and conventional proportional integral (PI) controller. The proposed FP-SEPIC/ZETA BDC with various control strategy is derived for simultaneous power management of a PV source using distributed maximum power point tracking (DMPPT) algorithm, a rechargeable battery, and a load by means of centralised controller. The steady state and the dynamic response of the FP-SEPIC/ZETA BDC are analysed using three different types of controllers under line and load regulation. The Fuzzy-PI-based control scheme improves the dynamic response of the system when compared with the FLC and the conventional PI controller. The power balance between the ports is achieved by pseudorandom carrier modulation scheme. The response of the FP-SEPIC/ZETA BDC is also validated experimentally using hardware prototype model of 500 W system. The effectiveness of the control strategy is validated using simulation and experimental results.

  7. Variabilidade genética em isolados de Colletotrichum lindemuthianum (Glomerella cingulata f. sp. phaseoli) por meio de marcadores morfológicos

    OpenAIRE

    Souza, Breno Oliveira de

    2014-01-01

    Colletotrichum lindemuthianum (Glomerela cingulata f. sp. phaseoli) apresenta ampla variabilidade genética, demonstrada por suas caracteristicas morfológicas. Este trabalho objetivou caracterizar, por meio de marcadores morfológicos, diferentes isolados (LV4, LV33, LV47, LV51, LV71, LV76, LV77, LV79, LV80, LV81, LV82, LV83, LV84) de C. lindemuthianum (G. cingulata f. sp. phaseoli) e identificar marcadores morfológicos com uso potencial em análises genéticas. Foram avaliados os seguintes carac...

  8. Controle de Rhizoctonia solani e Fusarium oxysporum f.sp. phaseoli por biopreparados de isolados de Trichoderma spp.

    Directory of Open Access Journals (Sweden)

    Pedro Paulo Dias

    2013-12-01

    Full Text Available Os experimentos objetivaram avaliar em condições de casa de vegetação o biocontrole dos fitopatógenos Rhizoctonia solani (RS e Fusarium oxysporum f.sp. phaseoli (FOP em alface (Lactuca sativa L. cultivar Regina, e feijão-vagem (Phaseolus vulgaris L. cultivar Alessa, respectivamente, utilizando como agentes antagonistas, 10 isolados de Trichoderma spp. selecionados em testes in vitro. Foram feitos biopreparados à base de arroz previamente colonizado por isolados de Trichoderma spp. e posteriormente triturados. Para a realização dos testes, os biopreparados foram inoculados previamente na proporção de 10(9 conídios.mL-1, em substrato comercial para produção de mudas. Após sete dias, os patógenos foram introduzidos separadamente em duas concentrações distintas: R. solani na proporção de 144 mg de meio de arroz por kg de substrato e F. oxysporum f.sp. phaseoli inoculado na forma de suspensão contendo 4,75 x 10(6 conídios.mL-1. Avaliou-se a influência dos biopreparados na % de damping-off de pós-emergência em plantas de alface e a severidade de murcha em plantas de feijão-vagem. O biopreparado referente ao isolado T-03 foi o mais eficiente no controle de R. solani em plantas de alface cultivar Regina, por ter reduzido a incidência de damping-off de pós-emergência nessa cultura. Por outro lado, nenhum dos biopreparados apresentou efeito antagonista satisfatório à F. oxysporum f.sp. phaseoli em plantas de feijão-vagem.

  9. PV power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Within the international seminar of the Ostbayerisches Technologie-Transfer-Institut e.V. (OTTI) at 11th June, 2012 in Munich (Federal Republic of Germany), the following lectures were held: (1) Technical due diligence (Dietmar Obst); (2) Certification / rating system for large PV plants (Robert Pfatischer); (3) O and M requirements (Lars Rulf); (4) IR photography for large scale systems (Bernhard Weinreich); (5) New market models for PV systems - direct marketing and sales of PV electricity (Martin Schneider); (6) Needs and benefits for plant certification for grid connection and operation (Christoph Luetke-Lengerich); (7) Lare volume module testing / Screening in the field and workshop (Semir Merzoug); (8) Dismantling costs of large scale PV plants (Siegfried Schimpf).

  10. Grid integrated distributed PV (GridPV).

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2013-08-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functions are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in the OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function in the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  11. 带续流开关的中点箝位型非隔离光伏逆变器%A neutral point clamped non-isolated PV inverter with a freewheeling switch

    Institute of Scientific and Technical Information of China (English)

    叶海云; 马海啸

    2016-01-01

    为了满足非隔离光伏发电系统低漏电流的要求,提出了一种带续流开关的中点箝位型非隔离光伏逆变器。该拓扑在全桥逆变器的交流侧加入了一个续流开关,使得太阳能电池板输出端与电网断开,提高了非隔离光伏逆变器的转换效率。另一方面中点箝位电路的应用使得该拓扑在功率处理阶段和续流阶段的共模电压基本保持不变,降低了漏电流。详细分析了拓扑的工作原理,给出了其控制方法,并通过Saber仿真软件验证了带续流开关的中点箝位型非隔离光伏逆变器良好的共模特性。实验研制了一台300 W的原理样机验证了理论分析的正确性及仿真方案的可行性。%In order to meet the requirement of common-mode leakage current in photovoltaic ( PV) generation sys-tems, a neutral point clamped non-isolated PV inverter with a freewheeling switch is proposed .A freewheeling switch is added in AC side of the full bridge inverter in this topology , which will improve the non-isolated PV inverter conver-sion efficiency because the freewheeling switch makes the output of the solar panels off the grid .On the other hand , common-mode voltage remains constant on power processing and freewheeling stage owing to the neutral point clamped circuit.The operational principle of topology is analyzed in detail and its controlling strategy is introduced in this pa -per.It is proved that common-mode performance of the proposed topology was good by Saber simulation software .The effectiveness and feasibility of the proposed topology and strategy have been verified in a prototype rated at 300 W.

  12. Antagonism of Bacillus spp. against Xanthomonas campestris pv. campestris

    OpenAIRE

    Leila Monteiro; Rosa de Lima Ramos Mariano; Ana Maria Souto-Maior

    2005-01-01

    The antagonism of eight Bacillus isolates was investigated against nine strains of Xanthomonas campestris pv. campestris (causal agent of crucifers black rot) to assess the role of lipopeptides in this process. Antimicrobial and hemolytic (surfactant) activity tests were performed in vitro using agar diffusion methods. Antibiosis and hemolysis were positive for four Bacillus isolates against all X. campestris pv. campestris strains. The correlation observed between antimicrobial and hemolytic...

  13. PV-WEB: internet-based PV information tool

    Energy Technology Data Exchange (ETDEWEB)

    Cowley, P.

    2003-07-01

    This report gives details of a project to create a web-based information system on photovoltaic (PV) systems for the British PV Association (PV-UK) for use by decision makers in government, the utilities, and the housing and construction sectors. The project, which aims to provide an easily accessible tool for UK companies, promote PV technology, increase competitiveness, and identify market opportunities, is described. The design of the web site and its implementation and the evolution are discussed, along with the maintenance of the site by PV-UK and the opportunities offered to PV-UK Members.

  14. Infestação de Bemisia tabaci biótipo B e Caliothrips phaseoli em genótipos de feijoeiro Infestation of Bemisia tabaci biotype B and Caliothrips phaseoli on bean genotypes

    Directory of Open Access Journals (Sweden)

    Flávio Gonçalves de Jesus

    2010-01-01

    Full Text Available Avaliou-se o comportamento de genótipos de feijoeiro sob a infestação de Bemisia tabaci (Genn. biótipo B e Caliothrips phaseoli (Hood em condições de campo, nas épocas de cultivo "de inverno", "das águas" e "da seca". Adotou-se o delineamento de blocos casualizados em esquema de parcelas sub-subdividida (19x3x6, com 19 genótipos (IAC Tybatã, IAC Una, FT Nobre, Pérola, Gen 96A98-15-3-32-1, Gen 96A45-3-51-52-1, IAC Alvorada, IAC Diplomata, Gen 96A3-P1-1-1, LP 98-122, LP 02-130, LP 01-38, LP 9979, BRS-Pontal, BRS-Requinte, BRS-Triunfo, BRS-Grafite, CV-48 e Z-28, três épocas de cultivos (inverno, águas e seca e seis períodos de avaliação. As avaliações foram realizadas semanalmente, contando-se o número de ovos e ninfas de B. tabaci e ninfas de C. phaseoli em dez folíolos por parcela. Os genótipos IAC Una, Pérola, Gen 96A45-3-51-52-1, Gen 96A98-15-32-1, FT Nobre, IAC Tybatã, IAC Alvorada, LP 02-130, LP 01-38, LP 98-122, IAC Diplomata e Gen 96A3P1-1-1 foram menos ovipositados por B. tabaci no cultivo "das águas". Os genótipos Pérola, Gen 96A45-3-51-52-1, IAC Una, Gen 96A98-15-32-1, IAC Tybatã e FT Nobre foram menos infestados por C. phaseoli. A maior incidência de ninfas de mosca-branca ocorreu no fim de janeiro no cultivo "das águas" e início de maio no cultivo "da seca"; para tripés, foi em junho durante o cultivo "de inverno". A maior incidência da população de B. tabaci e C. phaseoli, ocorreu dos 46 aos 60 dias após a emergência das plantas.The response of bean genotypes to infestation of Bemisia tabaci (Genn. biotype B and Caliothrips phaseoli (Hood in field conditions on the winter, rainy and dry seasons was evaluated. The experiment was arranged in a randomized Sub-divided (19x3x6 blocks design with 19 genotypes (IAC Tybatã, IAC Una, FT Nobre, Pérola, Gen 96A98-15-3-32-1, Gen 96A45-3-51-52-1, IAC Alvorada, IAC Diplomata, Gen 96A3-P1-1-1, LP 98-122, LP 02-130, LP 01-38, LP 9979, BRS-Pontal, BRS

  15. PV power forecast using a nonparametric PV model

    OpenAIRE

    Almeida, Marcelo Pinho; Perpiñan Lamigueiro, Oscar; Narvarte Fernández, Luis

    2015-01-01

    Forecasting the AC power output of a PV plant accurately is important both for plant owners and electric system operators. Two main categories of PV modeling are available: the parametric and the nonparametric. In this paper, a methodology using a nonparametric PV model is proposed, using as inputs several forecasts of meteorological variables from a Numerical Weather Forecast model, and actual AC power measurements of PV plants. The methodology was built upon the R environment and uses Quant...

  16. PV investment in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Hueser, Pius [Nova Energy GmbH, (Switzerland)

    2007-06-15

    This presentation is mainly about how the PV market in Europe has been growing, and which elements are going to determine if this market succeed or failed not only in Europe but also in the rest of the world. In the first part of this presentation, it is mentioned how in 2005 the development of some PV technologies triggered the PV market growth without any marketing control. Then, there are explained the aspects that changed such situation out of control, therefore, it emerged the beginning of the consolidation of this market. There are briefly explained those factors that are going to determine if this market succeed or failed in the future. Finally, there are given examples of some the PV investments. [Spanish] Esta presentacion habla principalmente de la manera en como ha crecido el Mercado de sistemas fotovoltaicos en Europa, asi tambien se mencionan los elementos fundamentales que determinaran el exito o fracaso de este mercado, no solamente en Europa sino tambien en el resto del mundo, en un futuro. En la primera parte de esta presentacion, se describe como en el 2005, debido al desarrollo de algunas tecnologias fotovoltaicas se desencadeno el crecimiento desenfrenado del mercado fotovoltaico. Despues, se explican los aspectos que hicieron que dicho crecimiento tomara su curso, teniendo como resultado el inicio de un mercado mas consolidado. Se explican brevemente los factores que determinaran si este mercado encuentra el exito o el fracaso en un futuro. Finalmente, se dan ejemplos de algunas adquisiciones fotovoltaicas.

  17. Testing for PV Reliability (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.; Bansal, S.

    2014-09-01

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  18. Firefighter Safety for PV Systems

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Sera, Dezso; Spataru, Sergiu

    2015-01-01

    An important and highly discussed safety issue for photovoltaic (PV) systems is that as long as the PV panels are illuminated, a high voltage is present at the PV string terminals and cables between the string and inverters that is independent of the state of the inverter's dc disconnection switc...

  19. PV potential and potential PV rent in European regions

    DEFF Research Database (Denmark)

    Hansen, Anders Chr.; Thorn, Paul

    2013-01-01

    The paper provides a GIS based model for assessing the potentials of photovoltaic electricity in Europe by NUTS 2 regions. The location specific energy potential per PV-­‐panel area is estimated based on observations of solar irradiation, conversion efficiency, levelised costs and the social value...... of PV-­‐electricity. Combined with the potential density of PV-­‐panel area based on land cover and environental restrictions, the PV energy potential and the potential PV ressource rent is calculated. These calculations enbable the model to estimate the regional patterns at NUTS 2 level...

  20. PV potential and potential PV rent in European regions

    DEFF Research Database (Denmark)

    Hansen, Anders Chr.; Thorn, Paul

    2013-01-01

    The paper provides a GIS based model for assessing the potentials of photovoltaic electricity in Europe by NUTS 2 regions. The location specific energy potential per PV-­‐panel area is estimated based on observations of solar irradiation, conversion efficiency, levelised costs and the social value...... of PV-­‐electricity. Combined with the potential density of PV-­‐panel area based on land cover and environental restrictions, the PV energy potential and the potential PV ressource rent is calculated. These calculations enbable the model to estimate the regional patterns at NUTS 2 level...

  1. “Tropicalisation” of Feed-in Tariffs: a custom-made support scheme for hybrid PV/diesel systems in isolated regions

    NARCIS (Netherlands)

    Solano-Peralta, M.; Moner-Girona, M.; van Sark, W.G.J.H.M.; Vallvè, X.

    2009-01-01

    The interest and actions towards introducing renewables for off-grid regions has increased due to their ostensible cost-effectiveness, eco-friendliness and quality services provided. Nevertheless, in many isolated areas diesel generators appear as a common option, confirming that there is a need for

  2. Neutral Point Clamped Non-isolated Full Bridge PV Grid-connected Inverters%中点钳位非隔离全桥光伏并网逆变器

    Institute of Scientific and Technical Information of China (English)

    张犁; 孙凯; 冯兰兰; 吴红飞; 徐明; 邢岩

    2012-01-01

    Two types of basic switching cells,positive-neutral point clamped cell and negative-neutral point clamped cell,and a method to build neutral point clamped(NPC) full bridge photovoltaic(PV) grid-connected inverters with these two basic cells are proposed to meet the demand for non-isolated inverter topology applied in PV generation system.A family of novel NPC non-isolated full bridge PV grid-connected inverters,besides existing topologies such as oH5 and FB-DCBP,is derived.Operation modes of the PN-NPC topology are analyzed as an example in detail.Finally,both of the efficiency and common-mode performance of the proposed PN-NPC and Heric topologies were compared with experimental results.And the comparison results show that the proposed PN-NPC topology features better efficiency and common-mode performance than that of the Heric topology.%针对光伏发电系统对非隔离逆变电路的需求,提出构成一类中点钳位非隔离全桥光伏并网逆变器的2种基本开关单元:中点钳位正单元(positive-neutral point clamped cell,P-NPCC)和中点钳位负单元(negative-neutral point clampedc ell,N-NPCC)。提出由2种基本单元构造中点钳位全桥逆变器拓扑的生成机理和推演方法,按照该方法可以得到现有的中点钳位非隔离全桥光伏并网逆变器拓扑,如oH5、FB-DCBP以及一族新的中点钳位非隔离全桥并网逆变器拓扑。以所提PN-NPC拓扑为例详细分析了其工作原理,并实验比较了PN-NPC和Heric拓扑的变换效率和共模特性。所提拓扑的共模电压为恒定值,且其变换效率和共模特性均优于Heric拓扑。

  3. Measures for diffusion of solar PV in selected African countries

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Hansen, Ulrich Elmer; Mackenzie, Gordon A.;

    2015-01-01

    This paper investigates how African governments are considering supporting and promoting the diffusion of solar PV. This issue is explored by examining so-called ‘technology action plans (TAPs)’, which were main outputs of the Technology Needs Assessment project implemented in 10 African countries...... that governments’ strategies to promoting solar PV are moving from isolated projects towards frameworks for market development and that there are high expectations to upgrading in the PV value chain through local assembly of panels and local production of other system elements. Commonly identified measures include...... support to: local production; financing schemes; tax exemptions; establishment and reinforcement of standards; technical training; and research and development....

  4. Pseudomonas cannabina pv. cannabina pv. nov., and Pseudomonas cannabina pv. alisalensis (Cintas Koike and Bull, 2000) comb. nov., are members of the emended species Pseudomonas cannabina (ex Sutic & Dowson 1959) Gardan, Shafik, Belouin, Brosch, Grimont & Grimont 1999.

    Science.gov (United States)

    Bull, Carolee T; Manceau, Charles; Lydon, John; Kong, Hyesuk; Vinatzer, Boris A; Fischer-Le Saux, Marion

    2010-04-01

    Sequence similarity in the 16S rDNA gene confirmed that crucifer pathogen Pseudomonas syringae pv. alisalensis belongs to P. syringae sensu lato. In reciprocal DNA/DNA hybridization experiments, DNA relatedness was high (69-100%) between P. syringae pv. alisalensis strains and the type strain of P. cannabina (genomospecies 9). In contrast, DNA relatedness was low (below 48%) between P. syringae pv. alisalensis and reference strains from the remaining genomospecies of P. syringae including the type strain of P. syringae and reference strain of genomospecies 3 (P. syringae pv. tomato) although the well-known crucifer pathogen, P. syringae pv. maculicola, also belongs to genomospecies 3. Additional evidence that P. syringae pv. alisalensis belongs to P. cannabina was sequence similarity in five gene fragments used in multilocus sequence typing, as well as similar rep-PCR patterns when using the BOX-A1R primers. The description of P. cannabina has been emended to include P. syringae pv. alisalensis. Host range testing demonstrated that P. syringae pv. alisalensis strains, originally isolated from broccoli, broccoli raab or arugula, were not pathogenic on Cannabis sativa (family Cannabinaceae). Additionally, P. cannabina strains, originally isolated from the C. sativa were not pathogenic on broccoli raab or oat while P. syringae pv. alisalensis strains were pathogenic on these hosts. Distinct host ranges for these two groups indicate that P. cannabina emend. consists of at least two distinct pathovars, P. cannabina pv. cannabina pv. nov., and P. cannabina pv. alisalensis comb. nov. Pseudomonas syringae pv. maculicola strain CFBP 1637 is a member of P. cannabina.

  5. First report of the crucifer pathogen Pseudomonas cannabina pv. alisalensis causing bacterial blight on radish (Raphanus sativus) in Germany

    Science.gov (United States)

    Pseudomonas cannabina pv. alisalensis is a severe pathogen of crucifers across the U.S. We compared a strain isolated from diseased radish (Raphanus sativus) in Germany to pathotypes and additional strains of P. cannabina pv. alisalensis and P. syringae pv. maculicola. We demonstrated that the patho...

  6. PV-θ view of the zonal mean state of the atmosphere

    Directory of Open Access Journals (Sweden)

    Aarnout J. Van Delden

    2012-08-01

    Full Text Available The relation between zonal mean potential vorticity (PV in potential temperature (θ coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies are identified. One PV-anomaly, the ‘Ex-UTLS PV-anomaly’, coincides approximately with the extratropical tropopause (310–360 K. It is a permanent feature of the zonal mean state. The other PV-anomaly is located higher in the stratosphere. It exhibits a strong seasonal cycle, i.e. in winter, it is strongly positive, while in summer, it is weakly negative. In the Northern Hemisphere winter, the Ex-UTLS PV-anomaly and the stratospheric PV-anomaly are separated by a ‘surf-zone’, which is characterised by a negative PV-anomaly pole-wards of a positive PV-anomaly. Piecewise PV-inversion reveals that (1 the Ex-UTLS PV-anomaly induces the westerly winds in the troposphere and the lower stratosphere, including the subtropical jet, that (2 the positive stratospheric PV-anomaly induces the stratospheric polar night jet and that (3 the negative polar cap stratospheric PV-anomaly in summer reduces the westerly wind speeds in the troposphere and induces easterly winds in the stratosphere. The Ex-UTLS PV-anomaly is manifest mainly as an isentropic density- (or mass- anomaly. Piecewise PV-inversion of these anomalies in isolation should account for this by an appropriate adjustment of the lower boundary condition.

  7. PV Systems Reliability Final Technical Report: Ground Fault Detection

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.

  8. Impact of Photovoltaic Generation on Reliability of Small Isolated PV-Wind-Diesel-Battery Power Generation System%光伏发电对风光柴储小型孤立发电系统可靠性的影响

    Institute of Scientific and Technical Information of China (English)

    王凯; 栗文义; 张晓飞; 白新雷

    2013-01-01

    In view of complementary features between resources of wind energy and solar energy among seasons and between day and night, small isolated wind-PV-diesel-battery power generation systems can supply power for remote areas better. A reliability assessment model of power output and solar energy radiant quantity, in which the variation of inclination angle of photovoltaic (PV) cell panel is reflected, is established. Utilizing the well-being model based Monte Carlo simulation the reliability of small isolated wind-PV-diesel-battery power generation system is assessed. Based on the results from calculation example, the impacts of the inclination angle of PV cell panel, peak power output of PV generation and forced outage on the reliability of the small isolated power generation system, and the obtained results are available for reference to the planning, design and operation of small isolated wind-PV-diesel-battery power generation systems.%因风能和太阳能资源具有季节和昼夜上的互补特性,风光柴储小型孤立发电系统可较好地为偏远地区提供电力服务。建立了反映光伏电池板倾斜角变化的太阳能辐射量及功率输出的可靠性评估模型。采用基于well-being模型的蒙特卡罗模拟法评估了风光柴储小型孤立发电系统可靠性。结合算例分析了光伏电池板倾角、光伏发电峰值功率及强迫停运率等因素对系统可靠性的影响。结果可为风光柴储小型孤立发电系统规划、设计和运行提供指导和参考。

  9. PV water pumping: NEOS Corporation recent PV water pumping activities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, C.

    1995-11-01

    NEOS Corporation has been very active in PV-powered water pumping, particularly with respect to electric utilities. Most of the recent activity has been through the Photovoltaic Services Network (PSN). The PSN is an independent, not-for-profit organization comprised of all types of electric utilities: rural electric coops, public power districts, investor-owned utilities, and power marketing agencies. The PSN`s mission is to work pro-actively to promote utility involvement in PV through education and training. PV information is distributed by the PSN in three primary forms: (1) consultation with PSN technical service representatives: (2) literature generated by the PSN; and (3) literature published by other organizations. The PSN can also provide assistance to members in developing PV customer service programs. The PSN`s product support activities include consolidation of information on existing packaged PV systems and facilitation of the development of new PV product packages that meet utility-defined specifications for cost performance, and reliability. The PSN`s initial product support efforts will be focused on commercially available packaged PV systems for a variety of off-grid applications. In parallel with this effort, if no products exist that meet the PSN`s functional specifications, the PSN will initiate the second phase of product development support process by encouraging the development of new packaged systems. Through these services and product support activities, the PSN anticipates engaging all segments for the PV industry, thus providing benefits to PV systems suppliers as well as local PV service contractors.This paper describes field testing of pv power systems for water pumping.

  10. Battery Energy Storage System for PV Output Power Leveling

    Directory of Open Access Journals (Sweden)

    Rajkiran Singh

    2014-01-01

    Full Text Available Fluctuating photovoltaic (PV output power reduces the reliability in power system when there is a massive penetration of PV generators. Energy storage systems that are connected to the PV generators using bidirectional isolated dc-dc converter can be utilized for compensating the fluctuating PV power. This paper presents a grid connected energy storage system based on a 2 kW full-bridge bidirectional isolated dc-dc converter and a PWM converter for PV output power leveling. This paper proposes two controllers: a current controller using the d-q synchronous reference and a phase-shift controller. The main function of the current controller is to regulate the voltage at the high-side dc, so that the voltage ratio of the high-voltage side (HVS with low-voltage side (LVS is equal to the transformer turns ratio. The phase-shift controller is employed to manage the charging and discharging modes of the battery based on PV output power and battery voltage. With the proposed system, unity power factor and efficient active power injection are achieved. The feasibility of the proposed control system is investigated using PSCAD simulation.

  11. Measures for diffusion of solar PV in selected African countries

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Hansen, Ulrich Elmer; Mackenzie, Gordon A.

    2017-01-01

    that governments’ strategies to promoting solar PV are moving from isolated projects towards frameworks for market development and that there are high expectations to upgrading in the PV value chain through local assembly of panels and local production of other system elements. Commonly identified measures include......This paper investigates how African governments are considering supporting and promoting the diffusion of solar PV. This issue is explored by examining so-called ‘technology action plans (TAPs)’, which were main outputs of the Technology Needs Assessment project implemented in 10 African countries...... from 2010 to 2013. The paper provides a review of three distinct but characteristic trajectories for PV market development in Kenya (private-led market for solar home systems), Morocco (utility-led fee-for service model) and Rwanda (donorled market for institutional systems). The paper finds...

  12. Sensorless PV Array Diagnostic Method for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso; Spataru, Sergiu; Mathe, Laszlo

    2011-01-01

    This work proposes a temperature and irradiance sensorless diagnostic method suitable for small residential PV installations, focusing on detection of partial shadows. The method works by detection of failures in crystalline silicone PV arrays by concomitant monitoring of some of their key parame...

  13. Interband cascade (IC) photovoltaic (PV) architecture for PV devices

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rui Q.; Tian, Zhaobing; Mishima, Tetsuya D.; Santos, Michael B.; Johnson, Matthew B.; Klem, John F.

    2015-10-20

    A photovoltaic (PV) device, comprising a PV interband cascade (IC) stage, wherein the IC PV stage comprises an absorption region with a band gap, the absorption region configured to absorb photons, an intraband transport region configured to act as a hole barrier, and an interband tunneling region configured to act as an electron barrier. An IC PV architecture for a photovoltaic device, the IC PV architecture comprising an absorption region, an intraband transport region coupled to the absorption region, and an interband tunneling region coupled to the intraband transport region and to the adjacent absorption region, wherein the absorption region, the intraband transport region, and the interband tunneling region are positioned such that electrons will flow from the absorption region to the intraband transport region to the interband tunneling region.

  14. Field analysis of solar PV-based collective systems for rural electrification.

    OpenAIRE

    Díaz, P.; Peña, R.; Muñoz Cano, Javier; Arias, C. A.; Sandoval, D

    2011-01-01

    This article analyses the long-term performance of collective off-grid photovoltaic (PV) systems in rural areas. The use of collective PV systems for the electrification of small medium-size villages in developing countries has increased in the recent years. They are basically set up as stand-alone installations (diesel hybrid or pure PV) with no connection with other electrical grids. Their particular conditions (isolated) and usual installation places (far from commercial/industrial centers...

  15. A look into the invisible: ultraviolet-B sensitivity in an insect (Caliothrips phaseoli) revealed through a behavioural action spectrum.

    Science.gov (United States)

    Mazza, Carlos A; Izaguirre, Miriam M; Curiale, Javier; Ballaré, Carlos L

    2010-02-07

    Caliothrips phaseoli, a phytophagous insect, detects and responds to solar ultraviolet-B radiation (UV-B; lambda insects are sensitive. We constructed an action spectrum of thrips responses to light by studying their behavioural reactions to monochromatic irradiation under confinement conditions. Thrips were maximally sensitive to wavelengths between 290 and 330 nm; human-visible wavelengths (lambda >or= 400 nm) failed to elicit any response. All but six ommatidia of the thrips compound eye were highly fluorescent when exposed to UV-A of wavelengths longer than 330 nm. We hypothesized that the fluorescent compound acts as an internal filter, preventing radiation with lambda > 330 nm from reaching the photoreceptor cells. Calculations based on the putative filter transmittance and a visual pigment template of lambda(max) = 360 nm produced a sensitivity spectrum that was strikingly similar to the action spectrum of UV-induced behavioural response. These results suggest that specific UV-B vision in thrips is achieved by a standard UV-A photoreceptor and a sharp cut-off internal filter that blocks longer UV wavelengths in the majority of the ommatidia.

  16. Speedometers for PV generators; Drehzahlmesser fuer PV-Generatoren

    Energy Technology Data Exchange (ETDEWEB)

    Fritze, Peter; Weinreich, Bernhard [Solarschmiede GmbH, Muenchen (Germany). Engineering-Abt.

    2011-05-31

    To measure the generator power of an installed PV system, it is not enough to look into the specifications of hte module producers. Fast and independent data can be provided by characteristic curve meters.

  17. PV in a sports arena; PV im Hexenkessel

    Energy Technology Data Exchange (ETDEWEB)

    Hoeche, B.

    2008-05-19

    The German soccer club Werder Bremen is reconstructing its stadium. Apart from higher spectator comfort and a better atmosphere, there will also be PV systems on the roof and external walls of the arena. (orig.)

  18. Comparison of cytopathological changes of plant hosts infected with two Broad bean wilt virus 2 isolates PV131 and P158%蚕豆萎蔫病毒2号分离物PV131和P158侵染寄主植物的细胞病理比较观察

    Institute of Scientific and Technical Information of China (English)

    刘成科; 李燕宏; 王卫兵; 洪健; 周雪平

    2009-01-01

    透射电镜观察比较了蚕豆萎蔫病毒2号(BBWV-2)分离物PV131和P158侵染昆诺藜(Chenopodium quinoa)和蚕豆(Viciafaba)的细胞超微结构变化.结果显示:受PV131分离物侵染的昆诺藜叶肉细胞质中膜结构大茸增生,形成有膜状结构、大小泡囊及电子致密物质的特殊膜增生区;病毒粒子散布在细胞质中,形成大块结晶体和管状结构,该管状结构直径约75 nm,横切面由9个病毒粒子组成;受PV131侵染的蚕豆叶肉细胞中也形成膜增生区和管状结构,未见病毒结晶体.受P158分离物侵染的昆诺藜和蚕豆叶肉细胞病变情况与PV131分离物相似,形成膜增生区和相同的管状结构,在蚕豆叶肉细胞中也未观察到病毒结晶体.上述结果表明:2个BBWV-2分离物虽然在不同寄主植物上引起的细胞病变程度有差异,但其细胞病理学特征是由病毒基因结构所决定,与寄主的种类无关.

  19. An aquaporin PvTIP4;1 from Pteris vittata may mediate arsenite uptake.

    Science.gov (United States)

    He, Zhenyan; Yan, Huili; Chen, Yanshan; Shen, Hongling; Xu, Wenxiu; Zhang, Haiyan; Shi, Lei; Zhu, Yong-Guan; Ma, Mi

    2016-01-01

    The fern Pteris vittata is an arsenic hyperaccumulator. The genes involved in arsenite (As(III)) transport are not yet clear. Here, we describe the isolation and characterization of a new P. vittata aquaporin gene, PvTIP4;1, which may mediate As(III) uptake. PvTIP4;1 was identified from yeast functional complement cDNA library of P. vittata. Arsenic toxicity and accumulating activities of PvTIP4;1 were analyzed in Saccharomyces cerevisiae and Arabidopsis. Subcellular localization of PvTIP4;1-GFP fusion protein in P. vittata protoplast and callus was conducted. The tissue expression of PvTIP4;1 was investigated by quantitative real-time PCR. Site-directed mutagenesis of the PvTIP4;1 aromatic/arginine (Ar/R) domain was studied. Heterologous expression in yeast demonstrates that PvTIP4;1 was able to facilitate As(III) diffusion. Transgenic Arabidopsis showed that PvTIP4;1 increases arsenic accumulation and induces arsenic sensitivity. Images and FM4-64 staining suggest that PvTIP4;1 localizes to the plasma membrane in P. vittata cells. A tissue location study shows that PvTIP4;1 transcripts are mainly expressed in roots. Site-directed mutation in yeast further proved that the cysteine at the LE1 position of PvTIP4;1 Ar/R domain is a functional site. PvTIP4;1 is a new represented tonoplast intrinsic protein (TIP) aquaporin from P. vittata and the function and location results imply that PvTIP4;1 may be involved in As(III) uptake.

  20. PSCAD Modules Representing PV Generator

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2013-08-01

    Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

  1. Switchgrass (Panicum virgatum L. polyubiquitin gene (PvUbi1 and PvUbi2 promoters for use in plant transformation

    Directory of Open Access Journals (Sweden)

    LaFayette Peter R

    2011-07-01

    Full Text Available Abstract Background The ubiquitin protein is present in all eukaryotic cells and promoters from ubiquitin genes are good candidates to regulate the constitutive expression of transgenes in plants. Therefore, two switchgrass (Panicum virgatum L. ubiquitin genes (PvUbi1 and PvUbi2 were cloned and characterized. Reporter constructs were produced containing the isolated 5' upstream regulatory regions of the coding sequences (i.e. PvUbi1 and PvUbi2 promoters fused to the uidA coding region (GUS and tested for transient and stable expression in a variety of plant species and tissues. Results PvUbi1 consists of 607 bp containing cis-acting regulatory elements, a 5' untranslated region (UTR containing a 93 bp non-coding exon and a 1291 bp intron, and a 918 bp open reading frame (ORF that encodes four tandem, head -to-tail ubiquitin monomer repeats followed by a 191 bp 3' UTR. PvUbi2 consists of 692 bp containing cis-acting regulatory elements, a 5' UTR containing a 97 bp non-coding exon and a 1072 bp intron, a 1146 bp ORF that encodes five tandem ubiquitin monomer repeats and a 183 bp 3' UTR. PvUbi1 and PvUbi2 were expressed in all examined switchgrass tissues as measured by qRT-PCR. Using biolistic bombardment, PvUbi1 and PvUbi2 promoters showed strong expression in switchgrass and rice callus, equaling or surpassing the expression levels of the CaMV 35S, 2x35S, ZmUbi1, and OsAct1 promoters. GUS staining following stable transformation in rice demonstrated that the PvUbi1 and PvUbi2 promoters drove expression in all examined tissues. When stably transformed into tobacco (Nicotiana tabacum, the PvUbi2+3 and PvUbi2+9 promoter fusion variants showed expression in vascular and reproductive tissues. Conclusions The PvUbi1 and PvUbi2 promoters drive expression in switchgrass, rice and tobacco and are strong constitutive promoter candidates that will be useful in genetic transformation of monocots and dicots.

  2. Comparative analysis of PvPAP gene family and their functions in response to phosphorus deficiency in common bean.

    Directory of Open Access Journals (Sweden)

    Cuiyue Liang

    Full Text Available BACKGROUND: Purple acid phosphatases (PAPs play a vital role in adaptive strategies of plants to phosphorus (P deficiency. However, their functions in relation to P efficiency are fragmentary in common bean. PRINCIPAL FINDINGS: Five PvPAPs were isolated and sequenced in common bean. Phylogenetic analysis showed that PvPAPs could be classified into two groups, including a small group with low molecular mass, and a large group with high molecular mass. Among them, PvPAP3, PvPAP4 and PvPAP5 belong to the small group, while the other two belong to the large group. Transient expression of 35S:PvPAPs-GFP on onion epidermal cells verified the variations of subcellular localization among PvPAPs, suggesting functional diversities of PvPAPs in common bean. Quantitative PCR results showed that most PvPAPs were up-regulated by phosphate (Pi starvation. Among them, the expression of the small group PvPAPs responded more to Pi starvation, especially in the roots of G19833, the P-efficient genotype. However, only overexpressing PvPAP1 and PvPAP3 could result in significantly increased utilization of extracellular dNTPs in the transgenic bean hairy roots. Furthermore, overexpressing PvPAP3 in Arabidopsis enhanced both plant growth and total P content when dNTPs were supplied as the sole external P source. CONCLUSIONS: The results suggest that PvPAPs in bean varied in protein structure, response to P deficiency and subcellular localization. Among them, both PvPAP1 and PvPAP3 might function as utilization of extracellular dNTPs.

  3. 一种低漏电流六开关非隔离全桥光伏并网逆变器%H6 Non-isolated Full Bridge Grid-connected PV Inverters With Low Leakage Currents

    Institute of Scientific and Technical Information of China (English)

    张犁; 孙凯; 冯兰兰; 邢岩; 徐明

    2012-01-01

    为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有利于热应力均衡,且仍满足续流阶段光伏电池输出端与电网脱离的要求。详细分析拓扑的工作原理,并推论给出H6非隔离光伏并网逆变器的其它3种拓扑结构;比较分析了H5拓扑、Heric拓扑和H6拓扑的损耗和成本。通过1kW通用样机平台对比验证了上述3种拓扑的效率和共模特性。实验结果表明,H6拓扑的变换效率高于H5拓扑、但略低于Heric拓扑,共模特性优于Heric拓扑、但略劣于H5拓扑。%In order to meet the limit for common-mode leakage currents in grid-connected photovoltaic (PV) generation systems, a H6 non-isolated full bridge PV grid -connected inverter is proposed. In the power processing period, the grid-tied current flows through three power switches during one of half line cycles, while flows through only two power switches during another half line cycle. As a result, the conduction losses are reduced and the heat-stress balance is benefited with the proposed H6 topology, comparing with the H5 topology. The operation mode of the proposed topology is analyzed in detail and another three topologies of the H6 non-isolated full bridge grid-connected inverters has been derived. The power losses and costs are fairly compared among the H5 topology, Heric topology and the H6 topology. Finally, both of the conversion efficiency and common- mode performance of these topologies are compared with a universal prototype inverter rated at 1 kW. The experimental results show that the efficiency of the proposed H6 topology is higher than that of the H5 topology, while slightly being lower than that of the Heric topology. And the common

  4. Effect of bean genotypes, insecticides, and natural products on the control of Bemisia tabaci (Gennadius biotype B (Hemiptera: Aleyrodidae and Caliothrips phaseoli (Hood (Thysanoptera: Thripidae = Efeito de genótipos de feijoeiro, inseticida e produtos naturais no controle Bemisia tabaci (Gennadius biotipo B (Hemiptera: Aleyrodidae e Caliothrips phaseoli (Hood (Thysanoptera: Thripidae

    Directory of Open Access Journals (Sweden)

    Júlio Cesar Janini

    2011-07-01

    Full Text Available Effect of bean genotypes, insecticides, and natural products on the control of Bemisia tabaci (Gennadius biotype B (Hemiptera: Aleyrodidae and Caliothrips phaseoli (Hood (Thysanoptera: Thripidae. The influence of bean genotypes associated with neem oil as insecticide was evaluated to control B. tabaci (Gennadius biotype B and C. phaseoli (Hood during the wet season sowing. The experimental design used was the randomized block arrangement in a 4x4x3 factorial scheme, represented by genotypes, neem oil and insecticides respectively, with three replications. The genotypes Carioca, IAC Harmonia, IAC Centauro and Pérola were used. The evaluations were done at 14 and 42 days after seedling emergence, bycounting B. tabaci biotype B eggs and nymphs and C. phaseoli nymphs in the genotypes leaf. Conclusion: The B. tabaci biotype B eggs and nymphs number were smaller in IAC Centauro and higher in IAC Harmonia. The tested genotypes were similarly infested by C. phaseoli. IAC Centauro and IAC Harmonia genotypes associated with neem oil (highlighting the full dose – 1% provided lower number of whitefly eggs and thrips nymphs. Neem oil at the full dose alsoreduced whitefly nymph number. In the tested genotypes the insecticide provided reduction in the number of whitefly eggs and nymphs as well in the thrips nymphs, with increase in therecommend dose. Avaliou-se a influência de genótipos de feijoeiro associado à aplicação de óleo de nim e inseticida no controle de B. tabaci (Gennadius biótipo B e C. phaseoli (Hood na época de semeadura “das águas”. O delineamento experimental utilizados foi o de blocos casualizados dispostos em um esquema fatorial 4 x 3 x 3, representado por variedades, óleo de nim e inseticidas, respectivamente, com três repetições. Utilizaram-se os genótipos Carioca, IAC Harmonia, IAC Centauro e Pérola. As avaliações foram realizadas dos 14 aos 42 dias após a emergência das plantas, contando-se o número de ovos e

  5. Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Ainsworth, Nathan; Gotseff, Peter; Baker, Kyri

    2016-05-05

    A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed study could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.

  6. Large scale PV plants - also in Denmark. Project report

    Energy Technology Data Exchange (ETDEWEB)

    Ahm, P. (PA Energy, Malling (Denmark)); Vedde, J. (SiCon. Silicon and PV consulting, Birkeroed (Denmark))

    2011-04-15

    the associated levelized cost of electricity (LCOE) has been found to be in the range of DKK 1 - 1,16 per kWh. With the present wind turbine tariff at around DKK 0,60/kWh the economics in isolation present a bleak picture for LPV. However, over the last four decades the learning curve of the PV technology exhibits a cost reduction of about 20 % for every doubling of the production volume, and there is nothing to indicate that this learning curve trend will not continue in the coming two decades leading to increasing competitiveness for LPV in Denmark. (LN)

  7. PV system testing and standards

    Science.gov (United States)

    DeBlasio, Richard

    1999-03-01

    The U.S. Department of Energy (DOE) PV Program System Performance and Engineering Project is being conducted by The National Renewable Energy Laboratory (NREL), Sandia National Laboratories (SNL), Southwest Technology Development Institute (SWTDI), and Florida Solar Energy Center (FSEC). It provides PV system, subsystem, and component-level technology-performance characterization testing; test-method development and validation; national and international consensus standards and codes development, test-facility product certification, and laboratory-accreditation program implementation; and information exchange and technical assistance to the PV community. Emphasis is placed on reducing technical and infrastructural barriers to system acceptance, reducing life-cycle cost of systems, providing systems-engineering best practices and guidelines, and leading the national effort in performance and reliability testing, and consensus standards, codes, and certification program development and implementation—thereby ensuring that PV systems meet customers' needs and expectations. A summary of project activities, accomplishments, and future plans is provided and highlighted by an overview of PV system test-procedure and standards development.

  8. Low concentrator PV optics optimization

    Science.gov (United States)

    Sharp, Leonard; Chang, Ben

    2008-08-01

    Purpose: Cost reduction is a major focus of the solar industry. Thin film technologies and concentration systems are viable ways to reducing cost, with unique strengths and weakness for both. Most of the concentrating PV work focuses on high concentration systems for reducing energy cost. Meanwhile, many believe that low concentrators provide significant cost reduction potential while addressing the mainstream PV market with a product that acts as a flat panel replacement. This paper analyzes the relative benefit of asymmetric vs. symmetric optics for low-concentrators in light of specific PV applications. Approach: Symmetric and asymmetric concentrating PV module performance is evaluated using computer simulation to determine potential value across various geographic locations and applications. The selected optic design is modeled against standard cSi flat panels and thin film to determine application fit, system level energy density and economic value. Results: While symmetric designs may seem ideal, asymmetric designs have an advantage in energy density. Both designs are assessed for aperture, optimum concentration ratio, and ideal system array configuration. Analysis of performance across climate specific effects (diffuse, direct and circumsolar) and location specific effects (sunpath) are also presented. The energy density and energy production of low concentrators provide a compelling value proposition. More significantly, the choice of optics for a low concentrating design can affect real world performance. With the goal of maximizing energy density and return on investment, this paper presents the advantages of asymmetric optic concentration and illustrates the value of this design within specific PV applications.

  9. Planar holographic spectrum-splitting PV module design

    Science.gov (United States)

    Gordon, Michael; Zhang, Deming; Vorndran, Shelby; Russo, Juan M.; Luscombe, Christine K.; Shaheen, Sean E.; Kostuk, Raymond K.

    2012-10-01

    A design is presented for a planar spectrum-splitting photovoltaic (PV) module using Holographic Optical Elements (HOEs). A repeating array of HOEs diffracts portions of the solar spectrum onto different PV materials arranged in alternating strips. Several combinations of candidate PV materials are explored, and theoretical power conversion efficiency is quantified and compared for each case. The holograms are recorded in dichromated gelatin (DCG) film, an inexpensive material which is easily encapsulated directly into the panel. If desired, the holograms can focus the light to achieve concentration. The side-by-side split spectrum layout has advantages compared to a stacked tandem cell approach: since the cells are electrically isolated, current matching constraints are eliminated. Combinations of dissimilar types of cells are also possible: including crystalline, thin film, and organic PV cells. Configurations which yield significant efficiency gain using relatively inexpensive PV materials are of particular interest. A method used to optimize HOE design to work with a different candidate cells and different package aspect ratios is developed and presented. (Aspect ratio is width of the cell strips vs. the thickness of the panel) The relationship between aspect ratio and HOE performance properties is demonstrated. These properties include diffraction efficiency, spectral selectivity, tracking alignment sensitivity, and uniformity of cell illumination.

  10. PV-HYBRID and MINI-GRID. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    design and validation of PV-hybrid sysem technology for rural electrification programmes in remote areas of Europe (Xavier Valive); (17) Analysis of inverter-controlled Island grids - transient simulations with ATP-EMTP and PowerFactory (Martin Braun); (18) Design of a PV-diesel hybrid energy system (William Lawrance); (19) Hybrid storage systems in PV stand alone applications impact on sizing and performance (Julien Labbe); (20) Sizing and analysis of a small hydro PV hybrid system for the rural electrification in developing countries (Joseph Kenfack); (21) Identification of dynamic equivalents for microgrids with high penetration of solar energy using ANNs (F.O. Resende); (22) Constructing village PV hybrid power systems on a wide-scale in Western China: Experience gained (Henrik Bindner); (23) Experiences with large-scale construction of PH hybrid village power systems in Western China (Winfried Klinghammer); (24) A detailed data based analysis of the behaviour of a 10+5+20 KW wind-PV-diesel hybrid sysem (Luis M. Arribas); (25) PV hybrid village electrification in French Guyana (Christian Dumbs); (26) Energy consumption patterns in village PV-diesel-hybrid systems (Javier Munoz); (27) From Subag to Ponelo hybrid photovoltaic-diesel system in Indonesia, lessons learned (Adjat Sudradjat); (28) PV diesel hybrid system in rural Africa - an inter-disciplinary approach (Markus Landau); (29) Making PV-diesel hybrids and PV or wind mini-grids sustainable in remote developing country sites: the Nabouwalu case (Philippe Veyan); (30) Mini-grid for an isolated island sandwip in Bangladesh (B.K. Bala).

  11. Multilocus sequence typing of Pseudomonas syringae sensu lato confirms previously described genomospecies and permits rapid identification of P. syringae pv. coriandricola and P. syringae pv. apii causing bacterial leaf spot on parsley.

    Science.gov (United States)

    Bull, Carolee T; Clarke, Christopher R; Cai, Rongman; Vinatzer, Boris A; Jardini, Teresa M; Koike, Steven T

    2011-07-01

    Since 2002, severe leaf spotting on parsley (Petroselinum crispum) has occurred in Monterey County, CA. Either of two different pathovars of Pseudomonas syringae sensu lato were isolated from diseased leaves from eight distinct outbreaks and once from the same outbreak. Fragment analysis of DNA amplified between repetitive sequence polymerase chain reaction; 16S rDNA sequence analysis; and biochemical, physiological, and host range tests identified the pathogens as Pseudomonas syringae pv. apii and P. syringae pv. coriandricola. Koch's postulates were completed for the isolates from parsley, and host range tests with parsley isolates and pathotype strains demonstrated that P. syringae pv. apii and P. syringae pv. coriandricola cause leaf spot diseases on parsley, celery, and coriander or cilantro. In a multilocus sequence typing (MLST) approach, four housekeeping gene fragments were sequenced from 10 strains isolated from parsley and 56 pathotype strains of P. syringae. Allele sequences were uploaded to the Plant-Associated Microbes Database and a phylogenetic tree was built based on concatenated sequences. Tree topology directly corresponded to P. syringae genomospecies and P. syringae pv. apii was allocated appropriately to genomospecies 3. This is the first demonstration that MLST can accurately allocate new pathogens directly to P. syringae sensu lato genomospecies. According to MLST, P. syringae pv. coriandricola is a member of genomospecies 9, P. cannabina. In a blind test, both P. syringae pv. coriandricola and P. syringae pv. apii isolates from parsley were correctly identified to pathovar. In both cases, MLST described diversity within each pathovar that was previously unknown.

  12. Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, L.; Gostein, M.; Emery, K.

    2012-09-01

    As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of +/-5% for thermopile pyranometers and +/-2.4% for PV reference devices.

  13. Solar PV. Innovators talking; Zon PV. Innovators aan het woord

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-02-15

    Qualitative studies have been conducted of the results of completed projects focused on energy innovation, spread over the seven themes of the top sector Energy: Energy saving in industry, Energy conservation in the built environment, Gas, Bio-energy, Smart grids, Offshore Wind, Solar PV. This provides insight into the follow-up activities and lessons of some EOS (Energy Research Subsidy) completed projects with the aim to inspire, connect and strengthen the TKIs (Topconsortia for Knowledge and Innovation) and individual companies and researchers working on energy innovation. This report concerns the research on solar PV [Dutch] Er is een kwalitatief onderzoek uitgevoerd naar de resultaten van afgeronde projecten gericht op energie-innovatie, verdeeld over de zeven thema's van de topsector Energie: Energiebesparing in de industrie; Energiebesparing in de gebouwde omgeving; Gas; Bio-energie; Smart grids; Wind op zee; Zon-pv. Daarmee wordt inzicht gegeven in de vervolgactiviteiten en lessen van een aantal afgesloten EOS-projecten (Energie Onderzoek Subsidie) met het oog op het inspireren, verbinden en versterken van de TKI's (Topconsortia voor Kennis en Innovatie) en individuele bedrijven en onderzoekers die werken aan energie-innovatie. Dit rapport betreft het onderzoek naar zon PV.

  14. Van lPv4 naar lPv6

    NARCIS (Netherlands)

    Luiijf, H.A.M.

    2008-01-01

    Organisaties die het Internet Protocol(IP) gebruiken voor beveiligingsdoeleinden en aanbieders van beveiligingsproducten ontkomen de komende jaren niet aan de overgang naar het nieuwe protocol lPv6. Enerzijds is het gelukkig dat die overgang niet op één dag wereldwijd zal plaatsvinden, er is geen 'I

  15. PV opportunities in India

    Science.gov (United States)

    Stone, Jack L.; Ullal, Harin S.

    1996-01-01

    The growing middle class in India, coupled with a need for electricity to provide basic services to the masses, provides an opportunity to deploy photovoltaic systems in cost-effective applications ranging from grid-connected to isolated location requirements. This need is being satisfied by aggressive government programs, the availability of funds from agencies such as the World Bank, and the desire of Indian industries to form joint ventures for in-country manufacturing. The relaxed restrictions on doing business in India makes today's opportunities timely indeed.

  16. Progress & Frontiers in PV Performance

    Energy Technology Data Exchange (ETDEWEB)

    Deline, Chris; DiOrio, Nick; Jordan, Dirk; Toor, Fatima

    2016-09-12

    PowerPoint slides for a presentation given at Solar Power International 2016. Presentation includes System Advisor Model (SAM) introduction and battery modeling, bifacial PV modules and modeling, shade modeling and module level power electronics (MLPE), degradation rates, and PVWatts updates and validation.

  17. PV gold rush in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Daniela

    2011-07-01

    As a result of the Green Energy Act, the installed PV capacity in the Canadian province of Ontario has tripled in the year 2010. A generous feed-in tariff, aiming at maximum local added value, has attracted numerous international manufacturers. However, the rigorous rules committing the companies to 60 % inland production have provoked harsh criticism. (orig.)

  18. The case for better PV forecasting

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Efthymiou, Venizelos; Graditi, Giorgio

    2016-01-01

    Rising levels of PV penetration mean increasingly sophisticated forecasting technologies are needed to maintain grid stability and maximise the economic value of PV systems. The Grid Integration working group of the European Technology and Innovation Platform – Photovoltaics (ETIP PV) shares...... the results of its ongoing research into the advantages and limitations of current forecasting technologies....

  19. PV-wind hybrid system performance. A new approach and a case study

    Energy Technology Data Exchange (ETDEWEB)

    Arribas, Luis; Cano, Luis; Cruz, Ignacio [Departamento de Energias Renovables, CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain); Mata, Montserrat; Llobet, Ermen [Ecotecnia, Roc Boronat 78, 08005 Barcelona (Spain)

    2010-01-15

    Until now, there is no internationally accepted guideline for the measurement, data exchange and analysis of PV-Wind Hybrid Systems. As there is a need for such a tool, so as to overcome the barrier that the lack of confidence due to the absence of reliability means for the development of the market of Hybrid Systems, an effort has been made to suggest one tool for PV-Wind Hybrid Systems. The suggested guidelines presented in this work are based on the existing guidelines for PV Systems, as a PV-Wind Hybrid system can be roughly thought of as a PV System to which wind generation has been added. So, the guidelines for PV Systems are valid for the PV-Wind System, and only the part referred to wind generation should be included. This has been the process followed in this work. The proposed method is applied to a case study, the CICLOPS Project, a 5 kW PV, 7.5 kW Wind Hybrid system installed at the Isolated Wind Systems Test Site that CIEMAT owns in CEDER (Soria, Spain). This system has been fully monitored through a year and the results of the monitoring activity, characterizing the long-term performance of the system are shown in this work. (author)

  20. Grid Integrated Distributed PV (GridPV) Version 2.

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J.; Coogan, Kyle

    2014-12-01

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functio ns are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in th e OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function i n the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  1. Lightweight IMM PV Flexible Blanket Assembly

    Science.gov (United States)

    Spence, Brian

    2015-01-01

    Deployable Space Systems (DSS) has developed an inverted metamorphic multijunction (IMM) photovoltaic (PV) integrated modular blanket assembly (IMBA) that can be rolled or z-folded. This IMM PV IMBA technology enables a revolutionary flexible PV blanket assembly that provides high specific power, exceptional stowed packaging efficiency, and high-voltage operation capability. DSS's technology also accommodates standard third-generation triple junction (ZTJ) PV device technologies to provide significantly improved performance over the current state of the art. This SBIR project demonstrated prototype, flight-like IMM PV IMBA panel assemblies specifically developed, designed, and optimized for NASA's high-voltage solar array missions.

  2. Eumycetoma caused by Diaporthe phaseolorum (Phomopsis phaseoli): a case report and a mini-review of Diaporthe/Phomopsis spp invasive infections in humans.

    Science.gov (United States)

    Iriart, X; Binois, R; Fior, A; Blanchet, D; Berry, A; Cassaing, S; Amazan, E; Papot, E; Carme, B; Aznar, C; Couppié, P

    2011-10-01

    Diaporthe phaseolorum (syn. Phomopsis phaseoli) is a frequent fungal parasite of plants, present on all continents around the world. It has rarely been involved in human diseases. We report a case of eumycetoma with osteomyelitis of the forefoot caused by this fungus and diagnosed by molecular biology. The patient had positive HTLV-1 serology and was a farmer from French Guiana who walked barefoot. He was successfully treated with long-term oral itraconazole (400 mg/day). A review of the literature underlines the essential roles of plants and host immunosuppression in this infection and the favourable outcome with a triazole antifungal treatment. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  3. The high efficiency transformer-less PV inverter topologies derived from NPC topology

    DEFF Research Database (Denmark)

    Ma, Lin; Kerekes, Tamas; Teodorescu, Remus;

    2009-01-01

    The grid-connected photovoltaic (PV) systems are an important part of renewable energy sources and their integration is getting more and more widespread. In order to improve the efficiency, practicality and reliability of the PV systems, many kinds of new inverter topologies have been proposed...... to avoid using a grid isolation transformer. The NPC topology and two other derived topologies are presented and analyzed in this paper. Validated by experiments, it has been proven that they are very suitable for using in transformer-less PV applications due to high efficiency, low leakage current and EMI...

  4. A highly efficient PV system using a series connection of DC-DC converter output with a photovoltaic panel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho-sung [Department of Electrical Engineering, Pusan National University, Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea); New and Renewable Energy System Research Center, Korea Electro-technology Research Institute, 28-1, Sungju-dong Changwon-si, Kyungsannam-do, 641-120 (Korea); Kim, Jong-Hyun; Min, Byung-Duk; Yoo, Dong-Wook [New and Renewable Energy System Research Center, Korea Electro-technology Research Institute, 28-1, Sungju-dong Changwon-si, Kyungsannam-do, 641-120 (Korea); Kim, Hee-Je [Department of Electrical Engineering, Pusan National University, Jangjeon-dong, Geumjeong-gu, Busan 609-735 (Korea)

    2009-11-15

    A photovoltaic (PV) power conditioning system (PCS) must have high conversion efficiency and low cost. Generally, a PV PCS uses either a single string converter or a multilevel module integrated converter (MIC). Each of these approaches has both advantages and disadvantages. For a high conversion efficiency and low cost PV module, a series connection of a module integrated DC-DC converter output with a photovoltaic panel was proposed. The output voltage of the PV panel is connected to the output capacitor of the fly-back converter. Thus, the converter output voltage is added to the output voltage of the PV panel. The isolated DC-DC converter generates only the difference voltage between the PV panel voltage and the required total output voltage. This method reduces the power level of the DC-DC converter and enhances energy conversion efficiency compared with a conventional DC-DC converter. (author)

  5. Lightning protection of PV systems

    OpenAIRE

    Pons, Enrico; Tommasini, Riccardo

    2013-01-01

    Lightning strikes can affect photovoltaic (PV) generators and their installations, involving also the inverter's electronics. It is therefore necessary to evaluate the risk connected to lightning strikes in order to adopt the correct protective measures for the system. The Standard IEC (EN) 62305-2 reports the procedures for the risk calculation and for the choice of proper lightning protection systems. Usually the technical guidelines suggest protecting with SPDs (surge protective devices) b...

  6. PV output smoothing with energy storage.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Schoenwald, David Alan

    2012-03-01

    This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

  7. High-efficiency Transformerless PV Inverter Circuits

    OpenAIRE

    Chen, Baifeng

    2015-01-01

    With worldwide growing demand for electric energy, there has been a great interest in exploring photovoltaic (PV) sources. For the PV generation system, the power converter is the most essential part for the efficiency and function performance. In recent years, there have been quite a few new transformerless PV inverters topologies, which eliminate the traditional line frequency transformers to achieve lower cost and higher efficiency, and maintain lower leakage current as well. With an ov...

  8. Amplified fragment length polymorphism and multilocus sequence analysis-based genotypic relatedness among pathogenic variants of Xanthomonas citri pv. citri and Xanthomonas campestris pv. bilvae.

    Science.gov (United States)

    Bui Thi Ngoc, Lan; Vernière, Christian; Jouen, Emmanuel; Ah-You, Nathalie; Lefeuvre, Pierre; Chiroleu, Frédéric; Gagnevin, Lionel; Pruvost, Olivier

    2010-03-01

    Three pathogenic variants (i.e. pathotypes) have been described within Xanthomonas citri pv. citri, the causal agent of Asiatic citrus canker. Pathotype A strains naturally infect a wide range of Citrus species and members of some related genera. In contrast, pathotypes A* and A(w) have narrow host ranges within the genus Citrus and have been isolated from Mexican lime (Citrus aurantifolia L.) and from Mexican lime and alemow (Citrus macrophylla L.), respectively. We used amplified fragment length polymorphism (AFLP) and multilocus sequence analysis (MLSA) based on four partial housekeeping gene sequences (atpD, dnaK, efp and gyrB ) for the genotypic classification of Xanthomonas citri pv. citri and the poorly characterized citrus pathogen Xanthomonas campestris pv. bilvae. A Mantel test showed that genetic distances derived from AFLP and MLSA were highly correlated. X. campestris pv. bilvae showed a close relatedness to the type strain of X. citri, indicating that this pathovar should be reclassified as X. citri pv. bilvae. All pathotype A* and A(w) strains were most closely related to X. citri pv. citri strains with a wide host range (pathotype A), confirming previous DNA-DNA hybridization data. Pathotype A(w) should be considered a junior synonym of pathotype A* on the basis of pathogenicity tests, AFLP, MLSA and PCR using pathovar-specific primers. Evolutionary genome divergences computed from AFLP data suggested that pathotype A* (including A(w) strains) is a group of strains that shows a wider genetic diversity than pathotype A.

  9. P.V. Jensen-Klint

    DEFF Research Database (Denmark)

    Jensen, Thomas Bo

    2006-01-01

    Bogen præsenterer og analyserer P.V. Jensen-Klints samlede arkitekturproduktion samt en mindre del af hans øvrige kunstneriske arbejder. Bogen rummer en grundig biografi om P.V. Jensen-Klints liv og gerning og præsenterer for første gang hans samlede arkitekturproduktion.......Bogen præsenterer og analyserer P.V. Jensen-Klints samlede arkitekturproduktion samt en mindre del af hans øvrige kunstneriske arbejder. Bogen rummer en grundig biografi om P.V. Jensen-Klints liv og gerning og præsenterer for første gang hans samlede arkitekturproduktion....

  10. Electrical PV array reconfiguration strategy for energy extraction improvement in grid-connected PV systems

    OpenAIRE

    2009-01-01

    This paper applies a dynamical electrical array reconfiguration (EAR) strategy on the photovoltaic (PV) generator of a grid-connected PV system based on a plant-oriented configuration, in order to improve its energy production when the operating conditions of the solar panels are different. The EAR strategy is carried out by inserting a controllable switching matrix between the PV generator and the central inverter, which allows the electrical reconnection of the available PV modules. A...

  11. Antagonism of Bacillus spp. against Xanthomonas campestris pv. campestris

    Directory of Open Access Journals (Sweden)

    Leila Monteiro

    2005-01-01

    Full Text Available The antagonism of eight Bacillus isolates was investigated against nine strains of Xanthomonas campestris pv. campestris (causal agent of crucifers black rot to assess the role of lipopeptides in this process. Antimicrobial and hemolytic (surfactant activity tests were performed in vitro using agar diffusion methods. Antibiosis and hemolysis were positive for four Bacillus isolates against all X. campestris pv. campestris strains. The correlation observed between antimicrobial and hemolytic activities indicated that lipopeptides were involved in the antibiosis mechanism of the studied antagonists. Fermentation studies were carried out with the isolates that showed highest antimicrobial and hemolytic activities, to follow up growth and production of bioactive and surfactant compounds. Production of bioactive and surfactant compounds was observed during the late growth phase of the Bacillus isolates.Investigação sobre o antagonismo de oito isolados de Bacillus: B. subtilis R14, B. megaterium pv. cerealis RAB7, B. megaterium pv. cerealis C211, B. megaterium C116, Bacillus sp. RAB9, B. cereus C240, Bacillus sp. C11 e B. cereus C210, contra nove linhagens de X. campestris pv. campestris (bactéria responsável pela podridão negra das crucíferas foi realizada para se verificar a participação de lipopeptídeos neste mecanismo. Testes de atividades antimicrobiana e hemolítica (surfactante foram realizados, utilizando-se o método de difusão em ágar. Antibiose e hemólise foram positivas para quatro isolados de Bacillus: R14, RAB7, C116 e C210. A correlação observada entre as atividades antimicrobiana e a hemolítica indica que lipopeptídeos estão envolvidos no mecanismo de antibiose dos isolados investigados. As fermentações foram realizadas com os isolados que demonstraram melhores resultados nos testes de atividades antimicrobiana e hemolítica: R14, RAB7 e C116, para acompanhar o crescimento e a produção de compostos bioativos e

  12. 46 CFR 153.355 - PV venting systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false PV venting systems. 153.355 Section 153.355 Shipping... Systems § 153.355 PV venting systems. When Table 1 requires a PV venting system, the cargo tank must have a PV valve in its vent line. The PV valve must be located between the tank and any connection...

  13. 40 CFR 180.1261 - Xanthomonas campestris pv. vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages.

    Science.gov (United States)

    2010-07-01

    ... and Pseudomonas syringae pv. tomato specific Bacteriophages. 180.1261 Section 180.1261 Protection of.... vesicatoria and Pseudomonas syringae pv. tomato specific Bacteriophages. An exemption from the requirement of... syringae pv. tomato specific bacteriophages in or on pepper and tomato. ...

  14. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  15. Multifunctionality of PV shells; Multifunktionalitaet von PV-Fassaden

    Energy Technology Data Exchange (ETDEWEB)

    Erban, C. [Saint-Gobain Glass Solar, Aachen (Germany)

    2000-08-01

    Integrated PV systems have come a long way since the construciton of the first solar building shell eight years ago. All technical problems have be solved, and a multitude of solar wall elements are now available that enable architects and planners to design their own customised solar building. [German] Der Einsatz von gebaeudeintegrierter Photovoltaik hat in den nunmehr acht Jahren seit dem Bau der ersten Solarfassade erhebliche Fortschritte gemacht. In technischer Hinsicht ist heute nahezu alles moeglich. Der Umsetzung der einstigen Vision 'Jedem Gebaeude seine Solaranlage' steht heute nichts mehr entgegen, zumal zahlreiche Foerdermoeglichkeiten existieren. Die Vielzahl der Einsatz- und Kombinationsmoeglichkeiten von Solar-Fassadenelementen versetzen Planer und Architekten in die Lage, ihrer individuellen Idee einer gebaeudeintegrierten Solaranlage Gestalt zu geben. (orig.)

  16. PV integration into a CSP plant

    Science.gov (United States)

    Carvajal, Javier López; Barea, Jose M.; Barragan, Jose; Ortega, Carlos

    2017-06-01

    This paper describes a preliminary techno-economic analysis of the integration of a PV plant into an optimized Parabolic Trough Plant in order to reduce the online consumptions and thus, increase the net electricity injected into the grid. The idea is to assess the feasibility of such project and see what configuration would be the optimal. An extra effort has been made in terms of modelling as the analysis has to be done to the integrated CSP + PV plant instead of analyzing them independently. Two different technologies have been considered for the PV plant, fix and one-axis tracking. Additionally three different scenarios have been considered for the CSP plant auxiliary consumptions as they are essential for determining the optimal PV plant (the higher the auxiliary consumption the higher the optimal PV plant). As could be expected, the results for all cases with PV show an improvement in terms of electricity generation and also in terms of LCOE with respect to the CSP plant. Such improvement is slightly higher with tracking technology for this specific study. Although this exercise has been done to an already designed CSP plant (so only the PV plant had to be optimized), the methodology could be applied for the optimization of an integrated CSP + PV plant during the design phase.

  17. Distributed PV Adoption - Sensitivity to Market Factors

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2016-02-01

    NREL staff used the dSolar (distributed solar) model to forecast the adoption of distributed, behind-the-meter PV through the year 2050 for 9 different scenarios. The scenarios varied in their assumptions about a carbon tax, the cost of PV systems in the future, and what credit would be given for excess generation once current net metering policies expire.

  18. Isolation

    DEFF Research Database (Denmark)

    Agerholm, Frank Juul

    2011-01-01

    Næringsstoffet har i dette nummer sat fokus på ”velvære i vinterkulden”, ”indendørsaktiviteter” og ”fedtafgift”. I klummen vises det, at disse tre fokusområder, der for en umiddelbar betragtning måske nok synes noget uensartede, falder sammen i ét tema: Isolation!......Næringsstoffet har i dette nummer sat fokus på ”velvære i vinterkulden”, ”indendørsaktiviteter” og ”fedtafgift”. I klummen vises det, at disse tre fokusområder, der for en umiddelbar betragtning måske nok synes noget uensartede, falder sammen i ét tema: Isolation!...

  19. Global PV markets and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Wolfsegger, Cristoph [European Photolvoltaic Industry Association (EPIA), Brussels, Belgium (Belgium)

    2007-06-15

    This presentation mainly talks about the global importance of the PV industry, not only in the environmental sphere but also in the economic sphere. It is firstly given the major information of the European Photovoltaic Industry Association (EPIA), where there can be found the lists of those full member countries that work as: components manufacturers, consulting, and associate members. Then, it is given a briefly explanation about the Alliance for Rural Electrification (ARE), and the reasons why the -PV systems- are almost the panacea to both the energy and the environmental issue. In addition, it is given the most relevant information about how to implement this system in those regions that have not yet implemented it. Besides, there are explained some of the benefits that this system has. It is shortly explained how this system is working in German and it is also shown a comparison chart about the photovoltaic feed-in tariffs. There are shown some graphics and charts having information related to the global markets and the global installations of PV systems and other issues related to them. [Spanish] Esta presentacion habla principalmente acerca de la importancia que hoy en dia tiene la industria fotovoltaica alrededor del mundo, esto no solo ocurre en el ambito ambiental sino tambien en el economico. En la primer parte se muestra la informacion mas importante acerca de la Asociacion Europea de la Industria Fotovoltaica (EPIA por sus siglas en ingles), en donde se encuentran las listas de los paises que son miembros permanentes trabajando como: fabricantes de componentes, asesores y miembros asociados. Enseguida, se da, de manera escueta, una explicacion acerca de la ARE, asi como las razones por las que los sistemas fotovoltaicos son casi la panacea tanto para los problemas ambientales como para los energeticos. Ademas, se explica la informacion mas relevante acerca de como implementar este sistema en aquellas partes del mundo que todavia no lo han realizado

  20. Optimal design of PV and HP system

    DEFF Research Database (Denmark)

    Nepper-Rasmussen, Bjarke Christian; Rasmussen, Theis Bo

    2015-01-01

    electric energy demand of the HP to hours where excess PV power is present. The self-consumption of the PV energy affects the overall net present value (NPV). In this paper, a method which maximizes the NPV by finding the cost-optimal combination of PV, HP and BT sizes, is proposed. Results show...... that the thermal storage with a BT is a better investment than a PV system without HP or no investment. Furthermore, it showed that the optimization model developed in this project is capable of finding the optimal combination of component sizes based on our data....... is described, where the thermal energy is stored in a buffer tank (BT) capable of dispersing heat to either the heating system of a house or a hot water tank, for later use. The thermal storage solution including a BT can increase the self-consumption of residentially produced PV power and thereby shift...

  1. The Ramakrishna Mission economic PV development initiative

    Energy Technology Data Exchange (ETDEWEB)

    Stone, J.L.; Ullal, H.S. [National Renewable Energy Lab., Golden, CO (United States); Sherring, C. [Sherring Energy Associates, Princeton, NJ (United States)

    1998-09-01

    India is the world`s second most populous country, quickly approaching one billion persons. Although it has a well-developed electricity grid, many of the people have little or no access to electricity and all of the benefits associated with it. There are areas that are isolated from the grid and will not be connected for many years, if ever. One such area is the Sundarbans located in the delta region of the two great rivers, the Ganges and Brahmaputra, partially in India and partially in Bangladesh. It is estimated that 1.5 million people live in this area, crisscrossed by many islands and rivers, who have only marginal supplies of electricity generated primarily from diesel generators and batteries. Working with the regional non-governmental organization (NGO), the Ramakrishna Mission, and the West Bengal Renewable Energy Development Agency, the governments of India and the US initiated a rural electrification initiative to demonstrate the economic and technical feasibility of photovoltaics to provide limited supplies of electricity for such applications as solar home lighting systems (SHS), water pumping, vaccine refrigeration, communications, and economic development activities. This paper details initial results from approximately 30 kilowatts of PV systems installed in the area, including socio-economic impacts and technical performance.

  2. Power of design - the future of building-integrated PV

    Energy Technology Data Exchange (ETDEWEB)

    Abbate, Cinzia [ENEL, Rome (Italy). Officine di Architettura

    2001-04-01

    This paper discusses strategies to make building integrated photovoltaic (PV) systems more acceptable and to allow PV material to compete with conventional construction material. The history of developments in building integration and difficulties encountered by architects wishing to use PV products are explored, and the Dutch Amersfoot project in Utrecht involving a new suburb of 501 house covered with PV panels is described. Questions raised regarding architectural integration of PV systems, and PV systems and the construction market are discussed. The Italian PV programme, financial and political constraints, and the positioning of PV on existing structures are reported.

  3. A three-pulmonary vein isolation approach to treat paroxysmal atrial fibrillation

    Institute of Scientific and Technical Information of China (English)

    Lexin WANG; Jing ZHOU

    2004-01-01

    Objective To investigate the safety and efficacy of a 3-pulmonary vein (PV) isolation approach in treating paroxysmal atrial fibrillation (AF). Methods Radiofrequency catheter ablation was used to eliminate PV potential in 11 patterns with frequent paroxysmal AF refractory to anti-arrhythmic agents. During sinus rhythm, PV potential was mapped in the left and right superior PVs and left inferior PV. The procedural success was defined as the elimination of PV potential in the 3 PVs. Restults PV potential was identified and abolished in a total of 24 PVs, mostly in the left and right superior PV. There was no pulmonary stenosis or other complications during or after the procedures. AF recurred in one patient after an average of 12 ± 3 month follow-up. Conclusions PV potemials were present mostly in the left or right superior PV. The 3-PVs isolation approach is safe and effective in preventing drug-resistant paroxysmal AF.

  4. Origin of the Outbreak in France of Pseudomonas syringae pv. actinidiae Biovar 3, the Causal Agent of Bacterial Canker of Kiwifruit, Revealed by a Multilocus Variable-Number Tandem-Repeat Analysis

    Science.gov (United States)

    Cunty, A.; Cesbron, S.; Poliakoff, F.; Jacques, M.-A.

    2015-01-01

    The first outbreaks of bacterial canker of kiwifruit caused by Pseudomonas syringae pv. actinidiae biovar 3 were detected in France in 2010. P. syringae pv. actinidiae causes leaf spots, dieback, and canker that sometimes lead to the death of the vine. P. syringae pv. actinidifoliorum, which is pathogenic on kiwi as well, causes only leaf spots. In order to conduct an epidemiological study to track the spread of the epidemics of these two pathogens in France, we developed a multilocus variable-number tandem-repeat (VNTR) analysis (MLVA). MLVA was conducted on 340 strains of P. syringae pv. actinidiae biovar 3 isolated in Chile, China, France, Italy, and New Zealand and on 39 strains of P. syringae pv. actinidifoliorum isolated in Australia, France, and New Zealand. Eleven polymorphic VNTR loci were identified in the genomes of P. syringae pv. actinidiae biovar 3 ICMP 18744 and of P. syringae pv. actinidifoliorum ICMP 18807. MLVA enabled the structuring of P. syringae pv. actinidiae biovar 3 and P. syringae pv. actinidifoliorum strains in 55 and 16 haplotypes, respectively. MLVA and discriminant analysis of principal components revealed that strains isolated in Chile, China, and New Zealand are genetically distinct from P. syringae pv. actinidiae strains isolated in France and in Italy, which appear to be closely related at the genetic level. In contrast, no structuring was observed for P. syringae pv. actinidifoliorum. We developed an MLVA scheme to explore the diversity within P. syringae pv. actinidiae biovar 3 and to trace the dispersal routes of epidemic P. syringae pv. actinidiae biovar 3 in Europe. We suggest using this MLVA scheme to trace the dispersal routes of P. syringae pv. actinidiae at a global level. PMID:26209667

  5. Multifunctional a-Si PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Peippo, K.; Lund, P.; Vartiainen, E. [Helsinki Univ. of Technology, Otaniemi (Finland). Advanced Energy Systems

    1998-10-01

    The optimal use of the various forms of solar energy (passive, active, daylighting, photovoltaics) in buildings calls for an optimal integration of the technologies. As energy conservation potential in space heating may soon be exhausted, electricity efficiency and on-site generation will play an increasing role in energy-conscious building design. There, dispersed PV systems integrated into buildings show a significant market potential, due to a number of benefits: no extra land area is required, PV-array may replace conventional cladding materials and become a building element. Moreover, the produced PV-electricity is more valuable for the building owner than for an electric utility

  6. Using a nonparametric PV model to forecast AC power output of PV plants

    OpenAIRE

    Almeida, Marcelo Pinho; Perpiñan Lamigueiro, Oscar; Narvarte Fernández, Luis

    2015-01-01

    In this paper, a methodology using a nonparametric model is used to forecast AC power output of PV plants using as inputs several forecasts of meteorological variables from a Numerical Weather Prediction (NWP) model and actual AC power measurements of PV plants. The methodology was built upon the R environment and uses Quantile Regression Forests as machine learning tool to forecast the AC power with a confidence interval. Real data from five PV plants was used to validate the methodology, an...

  7. A Practical Optimization Method for Designing Large PV Plants

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Koutroulis, E.; Eyigun, S.

    2011-01-01

    Nowadays Photovoltaic (PV) plants have multi MW sizes, the biggest plants reaching tens of MW of capacity. Such large-scale PV plants are made up of several thousands of PV panels, each panel being in the range of 150-350W. This means that the design of a Large PV power plant is a big challenge...

  8. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  9. Distributed PV Adoption in Maine Through 2021

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter; Sigrin, Ben

    2015-11-06

    NREL has used its dSolar (distributed solar) model to generate low-medium-high estimates of distributed PV adoption in Maine through 2021. This presentation gives a high-level overview of the model and modeling results.

  10. Transformerless PV inverters. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Borup, U.

    2009-12-15

    Since the start of the project the market for grid connected PV inverters have developed further. When the project started three - phase inverter were only available in high power systems. The technology developed within this project will enable three phase technology also to be implemented in string inverters for system down to 10 kW. We expect this to be very attractive due to the increased demand for symmetrical feed-in to the grid. The project relevance is therefore high and the sector continues to develop very much driven by technology. Especially the inverter technology is getting a lot of focus. The inverter systems are expected to take a much larger role in supporting the electrical grid in the future. The technology platform developed within the project is prepared to be extended with these utility functionalities. The main results of the project were: 1) A new technology concept for transformer-less inverters has been demonstrated with a number of prototypes. 2) Efficiency above 97,7% has been proven. 3) Efficiency and Maximum power point tracking has been optimized to ensure that almost all energy produced of the panels is transferred to the grid. 4) The platform is developed with a very fast control board, which enables extended functionality as demanding grid supporting functions in the future. Details about cost price and details about the control loop implementation is excluded from the report due to the competitive situation for Danfoss Solar Inverters A/S. (LN)

  11. Addressing firefighter safety around solar PV systems

    Energy Technology Data Exchange (ETDEWEB)

    Harris, B. [Sustainable Energy Technologies, Calgary, AB (Canada)

    2010-11-15

    The article discussed new considerations for installing photovoltaic (PV) systems that address the needs of fire service personnel. The presence of a PV system presents a multitude of dangers for firefighters, including electrical shock, the inhalation of toxic gases from being unable to cut a hole through the roof, falling debris and flying glass, and dead loading on a compromised structure and tripping on conduits. Mapping systems should be modified so that buildings with PV systems are identified for first responders, including firefighters who should learn that solar modules present an electrical hazard during the day but not at night; covering PV modules with foam or salvage covers may not shut the system down to a safe level; it takes a few moments for the power in PV modules to reduce to zero; and PV modules or conduit should never be cut, broke, chopped, or walked upon. The California Department of Forestry and Fire Protection recommends creating pathways and allowing easier access to the roof by setting the modules back from roof edges, creating a structurally sound pathway for firefighters to walk on and space to cut ventilation holes. However, the setback rule makes the economics of solar installation less viable for residential applications. The technological innovations aimed at addressing system safety all focus on limiting firefighter contact with live electrical components to within the extra-low-voltage (ELV) band. Some of the inverters on the market that support ELV system architecture were described. 1 fig.

  12. Updating Technical Screens for PV Interconnection: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Ellis, A.; Lynn, K.; Razon, A.; Key, T.; Kroposki, B.; Mather, B.; Hill, R.; Nicole, K.; Smith, J.

    2012-08-01

    Solar photovoltaics (PV) is the dominant type of distributed generation (DG) technology interconnected to electric distribution systems in the United States, and deployment of PV systems continues to increase rapidly. Considering the rapid growth and widespread deployment of PV systems in United States electric distribution grids, it is important that interconnection procedures be as streamlined as possible to avoid unnecessary interconnection studies, costs, and delays. Because many PV interconnection applications involve high penetration scenarios, the process needs to allow for a sufficiently rigorous technical evaluation to identify and address possible system impacts. Existing interconnection procedures are designed to balance the need for efficiency and technical rigor for all DG. However, there is an implicit expectation that those procedures will be updated over time in order to remain relevant with respect to evolving standards, technology, and practical experience. Modifications to interconnection screens and procedures must focus on maintaining or improving safety and reliability, as well as accurately allocating costs and improving expediency of the interconnection process. This paper evaluates the origins and usefulness of the capacity penetration screen, offers potential short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen.

  13. Effects of distilled Phaseoli Semen rubra Herbal-Acupuncture on lipid composition, liver function, antioxidant capacity and molecular biological aspects in obese rats induced high fat diet

    Directory of Open Access Journals (Sweden)

    Ji, Jun Hwan

    2005-06-01

    Full Text Available Effects of Phaseoli Semen rubra Herbal-acupuncture at zusanli(ST-36, Quchi(LI-11 and Sanyinjiao(Sp-6 on lipid composition, liver function, oxidative capacity and molecular biological aspects were investigate in high fat diet induced obese rats. Forty male Sprague-Dawley rats weighing about 400g were divided into 4 groups according to body weight and raised four weeks with control, zusanli(ST-36, Quchi(LI-11 and Sanyinjiao(Sp-6 Herbal-acupuncture groups. 1. Plasma total cholesterol and LDL-cholesterol showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups and HDL- cholesterol showed a high values in the (ST-36 Herbal-acupuncture groups. 2. Plasma triglyceride and glucose showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups. 3. The contents of plasma free fatty acids showed a tendence to decrease in the Herbal-acupuncture groups, however in the Herbal-acupuncture groups, the values showed no significantly different. 4. The activities of AST and ALT showed no significantly different in all treatment groups. 5. The contents of plasma β-lipoprotein and free fatty acids showed a tendency to decrease in the Herbal-acupuncture groups compared to those of control group. In the Herbal-acupuncture groups, the values of (ST-36 and (LI-11 Herbal-acupuncture groups showed a low in the acupuncture groups. 6. Liver total cholesterol and triglyceride showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups. 7. Contents of plasma TBARS showed a low values in the (ST-36 and (LI-11 Herbal-acupuncture groups, however contents of liver TBARS showed no significantly different among treatment groups. 8. Values of liver glutathione peroxidase and catalase activity showed a tendency to increase in the (ST-36 and (LI-11 Herbal-acupuncture groups. Values of liver super oxide dismutase activity showed a high in the (ST-36 Herbal-acupuncture groups compared to those of other groups. 9. Expression of apo-B mRNA in liver cell

  14. Differentially Expressed Genes in Resistant and Susceptible Common Bean (Phaseolus vulgaris L. Genotypes in Response to Fusarium oxysporum f. sp. phaseoli.

    Directory of Open Access Journals (Sweden)

    Renfeng Xue

    Full Text Available Fusarium wilt of common bean (Phaseolus vulgaris L., caused by Fusarium oxysporum Schlechtend.:Fr. f.sp. phaseoli (Fop, is one of the most important diseases of common beans worldwide. Few natural sources of resistance to Fop exist and provide only moderate or partial levels of protection. Despite the economic importance of the disease across multiple crops, only a few of Fop induced genes have been analyzed in legumes. Therefore, our goal was to identify transcriptionally regulated genes during an incompatible interaction between common bean and the Fop pathogen using the cDNA amplified fragment length polymorphism (cDNA-AFLP technique. We generated a total of 8,730 transcript-derived fragments (TDFs with 768 primer pairs based on the comparison of a moderately resistant and a susceptible genotype. In total, 423 TDFs (4.9% displayed altered expression patterns after inoculation with Fop inoculum. We obtained full amplicon sequences for 122 selected TDFs, of which 98 were identified as annotated known genes in different functional categories based on their putative functions, 10 were predicted but non-annotated genes and 14 were not homologous to any known genes. The 98 TDFs encoding genes of known putative function were classified as related to metabolism (22, signal transduction (21, protein synthesis and processing (20, development and cytoskeletal organization (12, transport of proteins (7, gene expression and RNA metabolism (4, redox reactions (4, defense and stress responses (3, energy metabolism (3, and hormone responses (2. Based on the analyses of homology, 19 TDFs from different functional categories were chosen for expression analysis using quantitative RT-PCR. The genes found to be important here were implicated at various steps of pathogen infection and will allow a better understanding of the mechanisms of defense and resistance to Fop and similar pathogens. The differential response genes discovered here could also be used as

  15. Differentially Expressed Genes in Resistant and Susceptible Common Bean (Phaseolus vulgaris L.) Genotypes in Response to Fusarium oxysporum f. sp. phaseoli.

    Science.gov (United States)

    Xue, Renfeng; Wu, Jing; Zhu, Zhendong; Wang, Lanfen; Wang, Xiaoming; Wang, Shumin; Blair, Matthew W

    2015-01-01

    Fusarium wilt of common bean (Phaseolus vulgaris L.), caused by Fusarium oxysporum Schlechtend.:Fr. f.sp. phaseoli (Fop), is one of the most important diseases of common beans worldwide. Few natural sources of resistance to Fop exist and provide only moderate or partial levels of protection. Despite the economic importance of the disease across multiple crops, only a few of Fop induced genes have been analyzed in legumes. Therefore, our goal was to identify transcriptionally regulated genes during an incompatible interaction between common bean and the Fop pathogen using the cDNA amplified fragment length polymorphism (cDNA-AFLP) technique. We generated a total of 8,730 transcript-derived fragments (TDFs) with 768 primer pairs based on the comparison of a moderately resistant and a susceptible genotype. In total, 423 TDFs (4.9%) displayed altered expression patterns after inoculation with Fop inoculum. We obtained full amplicon sequences for 122 selected TDFs, of which 98 were identified as annotated known genes in different functional categories based on their putative functions, 10 were predicted but non-annotated genes and 14 were not homologous to any known genes. The 98 TDFs encoding genes of known putative function were classified as related to metabolism (22), signal transduction (21), protein synthesis and processing (20), development and cytoskeletal organization (12), transport of proteins (7), gene expression and RNA metabolism (4), redox reactions (4), defense and stress responses (3), energy metabolism (3), and hormone responses (2). Based on the analyses of homology, 19 TDFs from different functional categories were chosen for expression analysis using quantitative RT-PCR. The genes found to be important here were implicated at various steps of pathogen infection and will allow a better understanding of the mechanisms of defense and resistance to Fop and similar pathogens. The differential response genes discovered here could also be used as molecular

  16. Complete Genome Sequences of Lytic Bacteriophages of Xanthomonas arboricola pv. juglandis.

    Science.gov (United States)

    Retamales, Julio; Vasquez, Ignacio; Santos, Leonardo; Segovia, Cristopher; Ayala, Manuel; Alvarado, Romina; Nuñez, Pablo; Santander, Javier

    2016-06-02

    Three bacteriophages, f20-Xaj, f29-Xaj, and f30-Xaj, with lytic activity against Xanthomonas arboricola pv. juglandis were isolated from walnut trees (VIII Bío Bío Region, Chile). These lytic bacteriophages have double-stranded DNA (dsDNA) genomes of 43,851 bp, 41,865 bp, and 44,262 bp, respectively. These are the first described bacteriophages with lytic activity against X. arboricola pv. juglandis that can be utilized as biocontrol agents.

  17. Common mode voltage in case of transformerless PV inverters connected to the grid

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco

    2008-01-01

    For safety reasons grid connected PV systems include galvanic isolation. In case of transformerless inverters, the leakage ground current through the parasitic capacitance of the PV panels, can reach very high values. A common-mode model based on analytical approach is introduced, used to predict...... the common-mode behavior, at frequencies lower than 50kHz, of the selected topologies and to explain the influence of system imbalance on the leakage current. It will be demonstrated that the neutral inductance has a crucial influence on the leakage current. Finally experimental results will be shown...

  18. Optimization of PV-based energy production by dynamic PV-panel/inverter configuration

    DEFF Research Database (Denmark)

    Paasch, Kasper; Nymand, Morten; Haase, Frerk

    This paper investigates the possible increase in annual energy production of a PV system with more than one MPPT (maximum power point tracker) input channels under Nordic illumination conditions, in case a concept of dynamic switching of the PV panels is used at the inputs of the inverters....

  19. PV performance modeling workshop summary report.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua S.; Tasca, Coryne Adelle (SRA International, Inc., Fairfax, VA); Cameron, Christopher P.

    2011-05-01

    During the development of a solar photovoltaic (PV) energy project, predicting expected energy production from a system is a key part of understanding system value. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, annual energy yield (kWh/kWp) will vary among module technologies because of differences in response to low-light levels and temperature. A number of PV system performance models have been developed and are in use, but little has been published on validation of these models or the accuracy and uncertainty of their output. With support from the U.S. Department of Energy's Solar Energy Technologies Program, Sandia National Laboratories organized a PV Performance Modeling Workshop in Albuquerque, New Mexico, September 22-23, 2010. The workshop was intended to address the current state of PV system models, develop a path forward for establishing best practices on PV system performance modeling, and set the stage for standardization of testing and validation procedures for models and input parameters. This report summarizes discussions and presentations from the workshop, as well as examines opportunities for collaborative efforts to develop objective comparisons between models and across sites and applications.

  20. PV system field experience and reliability

    Science.gov (United States)

    Durand, Steven; Rosenthal, Andrew; Thomas, Mike

    1997-02-01

    Hybrid power systems consisting of battery inverters coupled with diesel, propane, or gasoline engine-driven electrical generators, and photovoltaic arrays are being used in many remote locations. The potential cost advantages of hybrid systems over simple engine-driven generator systems are causing hybrid systems to be considered for numerous applications including single-family residential, communications, and village power. This paper discusses the various design constraints of such systems and presents one technique for reducing hybrid system losses. The Southwest Technology Development Institute under contract to the National Renewable Energy Laboratory and Sandia National Laboratories has been installing data acquisition systems (DAS) on a number of small and large hybrid PV systems. These systems range from small residential systems (1 kW PV - 7 kW generator), to medium sized systems (10 kW PV - 20 kW generator), to larger systems (100 kW PV - 200 kW generator). Even larger systems are being installed with hundreds of kilowatts of PV modules, multiple wind machines, and larger diesel generators.

  1. Integration of PV modules in existing Romanian buildings from rural areas

    Energy Technology Data Exchange (ETDEWEB)

    Fara, S.; Finta, D. [IPA SA Research Development, Engineering and Manufacturing for Automation Equipment and Systems, Bucharest (Romania); Fara, L.; Comaneci, D. [Polytechnic Univ. of Bucharest (Romania); Dabija, A.M. [Univ. of Architecture and Urbanism Ion Mincu, Bucharest (Romania); Tulcan-Paulescu, E. [West Univ. of Timisoara, Timisoara (Romania)

    2010-07-01

    Romania has launched a national research project to promote the use of distributed solar architecture and the use of BIPV systems. These systems include solar tunnels and active solar photovoltaic (PV) systems installed on the roofs and facades of buildings in rural areas. In contrast to other EU states, Romania does not have a photovoltaic building construction branch. The number of isolated cases are insufficient to identify a starting point regarding the PV market in the building industry. The main objective of the project is to demonstrate the efficiency of integrating various PV elements in buildings from rural areas, to test them and to make them known so that they can be used on a large scale. This will be accomplished by installing new products on 2 buildings in Bucharest and in 1 building in Timisoara. The PV modules will be integrated with the architecture. One of the buildings will be a historical building while the other 2 will be new buildings with different typologies. The installed power for each building will be of about 1.000 Wp, including some technologies with PV modules.

  2. Investigation of indirect benefits of PV rooftop in Thailand

    Science.gov (United States)

    Khumkrong, T.; Chuangchote, S.; Chenvidhya, D.; Kirtikara, K.

    2017-05-01

    Other than electricity generation, which is the direct benefit of PV rooftop, cooling load reduction due to PV shading is a benefit impact in the uses of PV rooftop. This report is a study of those indirect benefits of PV rooftop. Relation of shading of PV modules and reduction of cooling load was studied in a real testing cite at the office building of CES Solar Cell Testing Center (CSSC). Several data, i.e. solar radiation, rooftop temperatures before/after PV-panel installation, and electricity consumed by equipment, were monitored and collected. This data could be further estimated for cooling load via transient heat conduction approach.

  3. POWERED LED LIGHTING SUPPLIED FROM PV CELLS

    Directory of Open Access Journals (Sweden)

    Tirshu M.

    2011-12-01

    Full Text Available The paper deals with practical realization of efficient lighting system based on LED’s of 80W total power mounted on corridor ceiling total length of which is 120m and substitutes existing traditional lighting system consisting of 29 lighting blocks with 4 fluorescent lamps each of them and summary power 2088W. Realized lighting system is supplied from two photovoltaic panels of power 170W. Generated energy by PV cells is accumulated in two accumulators of 75Ah capacity and from battery by means of specialized convertor is applied to lighting system. Additionally, paper present data measured by digital weather station (solar radiation and UV index, which is mounted near of PV cells and comparative analyze of solar energy with real energy generated by PV cells is done. Measured parameters by digital weather station are stored by computer in on-line mode.

  4. PV Systems Reliability Final Technical Report.

    Energy Technology Data Exchange (ETDEWEB)

    Lavrova, Olga [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flicker, Jack David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jay [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Armijo, Kenneth Miguel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schindelholz, Eric John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sorensen, Neil R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Benjamin Bing-Yeh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The continued exponential growth of photovoltaic technologies paves a path to a solar-powered world, but requires continued progress toward low-cost, high-reliability, high-performance photovoltaic (PV) systems. High reliability is an essential element in achieving low-cost solar electricity by reducing operation and maintenance (O&M) costs and extending system lifetime and availability, but these attributes are difficult to verify at the time of installation. Utilities, financiers, homeowners, and planners are demanding this information in order to evaluate their financial risk as a prerequisite to large investments. Reliability research and development (R&D) is needed to build market confidence by improving product reliability and by improving predictions of system availability, O&M cost, and lifetime. This project is focused on understanding, predicting, and improving the reliability of PV systems. The two areas being pursued include PV arc-fault and ground fault issues, and inverter reliability.

  5. Terawatt Challenge for Thin-Film PV

    Energy Technology Data Exchange (ETDEWEB)

    Zweibel, K.

    2005-08-01

    The evolution of PV into one of the world's largest industries is not going to happen without major unforeseen problems. However, this study attempts to address the obvious ones, so that we can put aside the mythology of PV (for example, that it is only ''boutique power'' or that one must pave the world with it to be useful) and get on with changing the world's energy infrastructure. With the years of rapid market growth now under way in PV, the author is sure this will not be the last effort to understand the real potential and pitfalls of meeting the Challenge.

  6. PV panel model based on datasheet values

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2007-01-01

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....../panel in Standard Test Conditions (STC) are shown, as well as the parameters extraction from the data-sheet values. The temperature dependence of the cell dark saturation current is expressed with an alternative formula, which gives better correlation with the datasheet values of the power temperature dependence....... Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested....

  7. Advancement in solar PV Inverter

    Directory of Open Access Journals (Sweden)

    Devendra Doda

    2012-09-01

    Full Text Available This teardown article will delve into the architectural design and components of a solar inverter card starting from the Solar panel DC inputs and working through the DC to AC conversion process to the AC output that is sent out to the power grid. Features needed to be implemented into such a design to meet various safety and other performance standards as well as stringent power company demands upon the signal that is put onto their grid will be shown. In the process, major elements and component choices made in the design of the series of solar inverters, from the EMI suppression capacitors with a special emphasis on isolation and protection, through the smart use of optically isolated MOSFETgatedrivers.

  8. Real time PV manufacturing diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Kochergin, Vladimir [MicroXact Inc., Blacksburg, VA (United States); Crawford, Michael A. [MicroXact Inc., Blacksburg, VA (United States)

    2015-09-01

    The main obstacle Photovoltaic (PV) industry is facing at present is the higher cost of PV energy compared to that of fossil energy. While solar cell efficiencies continue to make incremental gains these improvements are so far insufficient to drive PV costs down to match that of fossil energy. Improved in-line diagnostics however, has the potential to significantly increase the productivity and reduce cost by improving the yield of the process. On this Phase I/Phase II SBIR project MicroXact developed and demonstrated at CIGS pilot manufacturing line a high-throughput in-line PV manufacturing diagnostic system, which was verified to provide fast and accurate data on the spatial uniformity of thickness, an composition of the thin films comprising the solar cell as the solar cell is processed reel-to-reel. In Phase II project MicroXact developed a stand-alone system prototype and demonstrated the following technical characteristics: 1) ability of real time defect/composition inconsistency detection over 60cm wide web at web speeds up to 3m/minute; 2) Better than 1mm spatial resolution on 60cm wide web; 3) an average better than 20nm spectral resolution resulting in more than sufficient sensitivity to composition imperfections (copper-rich and copper-poor regions were detected). The system was verified to be high vacuum compatible. Phase II results completely validated both technical and economic feasibility of the proposed concept. MicroXact’s solution is an enabling technique for in-line PV manufacturing diagnostics to increase the productivity of PV manufacturing lines and reduce the cost of solar energy, thus reducing the US dependency on foreign oil while simultaneously reducing emission of greenhouse gasses.

  9. Novel Methods to Determine Feeder Locational PV Hosting Capacity and PV Impact Signatures

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Coogan, Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Seuss, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    Often PV hosting capacity analysis is performed for a limited number of distribution feeders. For medium - voltage distribution feeders, previous results generally analyze less than 20 feeders, and then the results are extrapolated out to similar types of feeders. Previous hosting capacity research has often focused on determining a single value for the hosting capacity for the entire feeder, whereas this research expands previous hosting capacity work to investigate all the regions of the feeder that may allow many different hosting capacity values wit h an idea called locational hosting capacity (LHC)to determine the largest PV size that can be interconnected at different locations (buses) on the study feeders. This report discusses novel methods for analyzing PV interconnections with advanced simulati on methods. The focus is feeder and location - specific impacts of PV that determine the locational PV hosting capacity. Feeder PV impact signature are used to more precisely determine the local maximum hosting capacity of individual areas of the feeder. T he feeder signature provides improved interconnection screening with certain zones that show the risk of impact to the distribution feeder from PV interconnections.

  10. Seasonal energy storage - PV-hydrogen systems

    Energy Technology Data Exchange (ETDEWEB)

    Leppaenen, J. [Neste Oy/NAPS (Finland)

    1998-10-01

    PV systems are widely used in remote areas e.g. in telecommunication systems. Typically lead acid batteries are used as energy storage. In northern locations seasonal storage is needed, which however is too expensive and difficult to realise with batteries. Therefore, a PV- battery system with a diesel backup is sometimes used. The disadvantages of this kind of system for very remote applications are the need of maintenance and the need to supply the fuel. To overcome these problems, it has been suggested to use hydrogen technologies to make a closed loop autonomous energy storage system

  11. Updating Interconnection Screens for PV System Integration

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, M.; Mather, B.; Kroposki, B.; Lynn, K.; Razon, A.; Ellis, A.; Hill, R.; Key, T.; Nicole, K.; Smith, J.

    2012-02-01

    This white paper evaluates the origins and usefulness of the capacity penetration screen, offer short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen. Short-term and longer-term alternatives approaches are offered as examples; however, specific modifications to screening procedures should be discussed with stakeholders and must ultimately be adopted by state and federal regulatory bodies.

  12. MPPT algorithm for voltage controlled PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Teodorescu, Remus; Liserre, Marco;

    2008-01-01

    This paper presents a novel concept for an MPPT that can be used in case of a voltage controlled grid connected PV inverters. In case of single-phase systems, the 100 Hz ripple in the AC power is also present on the DC side. Depending on the DC link capacitor, this power fluctuation can be used t...... to track the MPP of the PV array, using the information that at MPP the power oscillations are very small. In this way the algorithm can detect the fact that the current working point is at the MPP, for the current atmospheric conditions....

  13. Large-Scale PV Integration Study

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Shuai; Etingov, Pavel V.; Diao, Ruisheng; Ma, Jian; Samaan, Nader A.; Makarov, Yuri V.; Guo, Xinxin; Hafen, Ryan P.; Jin, Chunlian; Kirkham, Harold; Shlatz, Eugene; Frantzis, Lisa; McClive, Timothy; Karlson, Gregory; Acharya, Dhruv; Ellis, Abraham; Stein, Joshua; Hansen, Clifford; Chadliev, Vladimir; Smart, Michael; Salgo, Richard; Sorensen, Rahn; Allen, Barbara; Idelchik, Boris

    2011-07-29

    This research effort evaluates the impact of large-scale photovoltaic (PV) and distributed generation (DG) output on NV Energy’s electric grid system in southern Nevada. It analyzes the ability of NV Energy’s generation to accommodate increasing amounts of utility-scale PV and DG, and the resulting cost of integrating variable renewable resources. The study was jointly funded by the United States Department of Energy and NV Energy, and conducted by a project team comprised of industry experts and research scientists from Navigant Consulting Inc., Sandia National Laboratories, Pacific Northwest National Laboratory and NV Energy.

  14. Crestamento foliar, nova sintomatologia em algodoeiro causada por Xanthomonas axonopodis pv. malvacearum Cotton leaf blight, a new symptomatology caused by Xanthomonas axonopodis pv. malvacearum

    Directory of Open Access Journals (Sweden)

    Valdemar Atílio Malavolta Jr.

    2008-06-01

    Full Text Available Foi observada recentemente no Estado de São Paulo uma nova sintomatologia em algodoeiro cv. Makina, IAC 24 e Detaopal, causada por Xanthomonas axonopodis pv. malvacearum (Xam, denominada "crestamento foliar". Caracteriza-se por crestamento foliar, geralmente acompanhado por halo clorótico, podendo também causar sintomas de "V" invertido, a partir dos bordos foliares. Linhagens de Xam foram comparadas, por meio de testes de patogenicidade, bioquímicos, sorológicos, culturais e PCR-RFLP da região espaçadora 16S-23S DNAr. Independentemente do tipo de sintoma, as linhagens apresentaram características e perfis idênticos aos apresentados pela linhagem tipo, confirmando a identidade dos isolados como Xanthomonas axonopodis pv. malvacearum.Recently a new symptomatology on cotton plants (cv. Makina, IAC 24 and Deltaopal caused by Xanthomonas axonopodis pv. malvacearum (Xam was observed in São Paulo state, Brazil, and named "bacterial leaf blight". The symptom was characterized by leaf blight, generally exhibiting chlorotic haloes and sometimes showing V-shaped lesions beginning at the leaves' border. Strains of Xam responsible for typical angular leaf spots and bacterial leaf blight were compared through pathological, biochemical, serological, cultural and RFLP-PCR tests of the 16S-23S spacer region. Independently of the symptom type, the strains exhibited characteristics and profiles that were identical to those exhibited by the type strain, which confirms the isolates identity Xanthomonas axonopodis pv. malvacearum

  15. International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, J.; Kurtz, S.

    2014-10-01

    The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests are being developed for each of the selected climate zones.

  16. Trimode Power Converter optimizes PV, diesel and battery energy sources

    Science.gov (United States)

    Osullivan, George; Bonn, Russell; Bower, Ward

    1994-12-01

    Conservatively, there are 100,000 localities in the world waiting for the benefits that electricity can provide, and many of these are in climates where sunshine is plentiful. With these locations in mind a prototype 30 kW hybrid system has been assembled at Sandia to prove the reliability and economics of photovoltaic, diesel and battery energy sources managed by an autonomous power converter. In the Trimode Power Converter the same power parts, four IGBT's with an isolation transformer and filter components, serve as rectifier and charger to charge the battery from the diesel; as a stand-alone inverter to convert PV and battery energy to AC; and, as a parallel inverter with the diesel-generator to accommodate loads larger than the rating of the diesel. Whenever the diesel is supplying the load, an algorithm assures that the diesel is running at maximum efficiency by regulating the battery charger operating point. Given the profile of anticipated solar energy, the cost of transporting diesel fuel to a remote location and a five year projection of load demand, a method to size the PV array, battery and diesel for least cost is developed.

  17. A Practical Irradiance Model for Bifacial PV Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-15

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors (CFs) to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using the RADIANCE ray tracing program.

  18. A Practical Irradiance Model for Bifacial PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill; MacAlpine, Sara; Deline, Chris; Asgharzadeh, Amir; Toor, Fatima; Riley, Daniel; Stein, Joshua; Hansen, Clifford

    2017-06-21

    A model, suitable for a row or multiple rows of photovoltaic (PV) modules, is presented for estimating the backside irradiance for bifacial PV modules. The model, which includes the effects of shading by the PV rows, is based on the use of configuration factors to determine the fraction of a source of irradiance that is received by the backside of the PV module. Backside irradiances are modeled along the sloped height of the PV module, but assumed not to vary along the length of the PV row. The backside irradiances are corrected for angle-of-incidence losses and may be added to the front side irradiance to determine the total irradiance resource for the PV cell. Model results are compared with the measured backside irradiances for NREL and Sandia PV systems, and with results when using ray tracing software.

  19. Design optimization of grid-connected PV inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    The DC/AC inverters are the key elements in grid-connected PV energy production systems. In this paper, new design optimization techniques focused on transformerless (very high efficiency) PV inverters are proposed. They have been developed based on an analysis of the deficiencies of the current......, state-of-the-art PV inverters design technology, which limits the amount of PV energy supplied into the electric grid. The influences of the electric grid regulations and standards and the PV array operational characteristics on the design of grid-connected PV inverters have also been considered....... The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy injected into the electric grid by the optimized PV installation....

  20. On the Impact of Partial Shading on PV Output Power

    DEFF Research Database (Denmark)

    Sera, Dezso; Baghzouz, Yahia

    2008-01-01

    clarifies the mechanism of partial PV shading on a number of PV cells connected in series and/or parallel with and without bypass diodes. The analysis is presented in simple terms and can be useful to someone who wishes to determine the impact of some shading geometry on a PV system. The analysis...... is illustrated by measurements on a commercial 70 W panel, and a 14.4 kW PV array....

  1. Final Technical Report: PV Fault Detection Tool.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The PV Fault Detection Tool project plans to demonstrate that the FDT can (a) detect catastrophic and degradation faults and (b) identify the type of fault. This will be accomplished by collecting fault signatures using different instruments and integrating this information to establish a logical controller for detecting, diagnosing and classifying each fault.

  2. PV producers must advertise; Werbung wird wichtiger

    Energy Technology Data Exchange (ETDEWEB)

    Seltmann, T.

    2001-01-12

    Producers of current inverters are profiting from the growing PV market. The bigger suppliers are enhancing their advertising and marketing efforts while smaller suppliers opt for high-efficiency technology. [German] Vom kraeftigen Wachstum des Photovoltaik-Marktes profitieren zwangslaeufig auch die Wechselrichter-Hersteller. Die groesseren Anbieter verstaerken Vertrieb und Marketing, waehrend die kleineren versuchen, mit besonders effizienter Technik zu glaenzen. (orig.)

  3. PV-mooduli toodang suurfarmis / Teolan Tomson

    Index Scriptorium Estoniae

    Tomson, Teolan, 1932-

    2015-01-01

    Artiklis uuritakse PV-paneelide tootlikkuse langust nende vastastikuse varjutamise tõttu. Näidatakse, et Eesti oludes on soovitav kasutada paneelide madalaid kaldenurki ja suhtelist reavahet, mis ületab paneeli kõrguse pooleteistkordset väärtust

  4. TRNSYS HYBRID wind diesel PV simulator

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, P.J.A.; Mitchell, J.W.; Klein, S.A.; Beckman, W.A.; Blair, N.J. [Univ. of Wisconsin, Madison, WI (United States)

    1996-12-31

    The Solar Energy Laboratory (SEL) has developed a wind diesel PV hybrid systems simulator, UW-HYBRID 1.0, an application of the TRNSYS 14.2 time-series simulation environment. An AC/DC bus links up to five diesels and wind turbine models, along with PV modules, a battery bank, and an AC/DC converter. Multiple units can be selected. PV system simulations include solar angle and peak power tracking options. Weather data are Typical Meteorological Year data, parametrically generated synthesized data, or external data files. PV performance simulations rely on long-standing SEL-developed algorithms. Loads data are read as scalable time series. Diesel simulations include estimated fuel-use and waste heat output, and are dispatched using a least-cost of fuel strategy. Wind system simulations include varying air density, wind shear and wake effects. Time step duration is user-selectable. UW-HYBRID 1.0 runs in Windows{reg_sign}, with TRNSED providing a customizable user interface. 12 refs., 6 figs.

  5. PV-mooduli toodang suurfarmis / Teolan Tomson

    Index Scriptorium Estoniae

    Tomson, Teolan, 1932-

    2015-01-01

    Artiklis uuritakse PV-paneelide tootlikkuse langust nende vastastikuse varjutamise tõttu. Näidatakse, et Eesti oludes on soovitav kasutada paneelide madalaid kaldenurki ja suhtelist reavahet, mis ületab paneeli kõrguse pooleteistkordset väärtust

  6. PV/T slates - Pilot project in Steinhausen; PV/T-Schiefer. Pilotprojekt Steinhausen

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report deals with a ventilated PV-tile system (PV/T-Slates) mounted on a garden shed in Steinhausen, Switzerland. The installation provides power and heat to the main house. The report describes the construction and operation of this pilot project and the results of measurements made on its electrical and thermal performance. The results of measurements made are presented in detail in graphical form and compared with the results of simulation. Suggestions are made for the optimisation of the system. Figures are presented on energy production and energy flows in graphical form.

  7. Commercialization of PV-powered pumping systems for use in utility PV service programs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The project described in this report was a commercialization effort focused on cost-effective remote water pumping systems for use in utility-based photovoltaic (PV) service programs. The project combined a commercialization strategy tailored specifically for electric utilities with the development of a PV-powered pumping system that operates conventional ac pumps rather than relying on the more expensive and less reliable PV pumps on the market. By combining these two attributes, a project goal was established of creating sustained utility purchases of 250 PV-powered water pumping systems per year. The results of each of these tasks are presented in two parts contained in this Final Summary Report. The first part summarizes the results of the Photovoltaic Services Network (PSN) as a new business venture, while the second part summarizes the results of the Golden Photon system installations. Specifically, results and photographs from each of the system installations are presented in this latter part.

  8. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module...

  9. The possibility of developing hybrid PV/T solar system

    Science.gov (United States)

    Dobrnjac, M.; Zivkovic, P.; Babic, V.

    2017-05-01

    An alternative and cost-effective solution to developing integrated PV system is to use hybrid photovoltaic/thermal (PV/T) solar system. The temperature of PV modules increases due to the absorbed solar radiation that is not converted into electricity, causing a decrease in their efficiency. In hybrid PV/T solar systems the reduction of PV module temperature can be combined with a useful fluid heating. In this paper we present the possibility of developing a new hybrid PV/T solar system. Hybrid PV/T system can provide electrical and thermal energy, thus achieving a higher energy conversion rate of the absorbed solar radiation. We developed PV/T prototype consisted of commercial PV module and thermal panel with our original solution of aluminium absorber with special geometric shapes. The main advantages of our combined PV/T system are: removing of heat from the PV panel; extending the lifetime of photovoltaic cells; excess of the removing heat from PV part is used to heat the fluid in the thermal part of the panel; the possibility of using on the roof and facade constructions because less weight.

  10. High Resolution PV Power Modeling for Distribution Circuit Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Norris, B. L.; Dise, J. H.

    2013-09-01

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  11. Determination of Parameters of PV Concentrating System With Heliostat

    Science.gov (United States)

    Vardanyan, R.; Norsoyan, A.; Dallakyan, V.

    2010-10-01

    The structure of PV concentrating system with heliostat is analyzed. The mathematical model of system consisting of PV concentrating module and heliostat is developed. With the use of developed mathematical model the optimal parameters of the system are determined. The results of this work can be used during the design of PV concentrating systems with heliostats.

  12. Assessing the need for better forecasting and observability of pv

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Efthymiou, Venizelos; Graditi, Giorgio

    2017-01-01

    In its review of the challenges and opportunities associated with massive deployment of solar PV generation, the Grid integration working group of the ETIP PV identified forecasting and observability as critical technologies for the planning and operation of the power system with large PV penetra...

  13. Beacons In Brief. P/PV In Brief. Issue 2

    Science.gov (United States)

    Blank, Susan; Farley, Chelsea

    2004-01-01

    This second issue in P/PV's "In Brief" series focuses on the San Francisco Beacon Initiative and P/PV's recently released evaluation results. The Beacon Initiative established after-school programs in eight public schools in low-income San Francisco neighborhoods. P/PV's 36-month evaluation examined key developmental and academic outcomes.…

  14. Novel Rhizobium lineages isolated from root nodules of the common bean (Phaseolus vulgaris L.) in Andean and Mesoamerican areas.

    Science.gov (United States)

    Ribeiro, Renan Augusto; Ormeño-Orrillo, Ernesto; Dall'Agnol, Rebeca Fuzinatto; Graham, Peter H; Martinez-Romero, Esperanza; Hungria, Mariangela

    2013-09-01

    The taxonomic affiliations of nineteen root-nodule bacteria isolated from the common bean (Phaseolus vulgaris L.) in Mexico, Ecuador and Brazil were investigated by analyses of 16S rRNA and of four protein-coding housekeeping genes. One strain from Mexico could be assigned to Rhizobium etli and two from Brazil to Rhizobium leucaenae, whereas another from Mexico corresponded to a recently described bean-nodulating species-level lineage related to R. etli and Rhizobium phaseoli. Ten strains isolated in Ecuador and Mexico corresponded to three novel Rhizobium lineages that fall into the R. phaseoli/R. etli/Rhizobium leguminosarum clade. One of those lineages, with representatives isolated mostly from Ecuador, seems to be dominant in beans from that Andean region. Only one of the Mexican strains clustered within the Rhizobium tropici clade, but as an independent lineage. Interestingly, four strains were affiliated with species within the Rhizobium radiobacter clade. The existence of yet non-described native Rhizobium lineages in both the Andean and Mesoamerican areas is discussed in relation to common-bean diversity and environmental conditions.

  15. Technologies to Increase PV Hosting Capacity in Distribution Feeders: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-08-01

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  16. Remote and Centralized Monitoring of PV Power Plants

    DEFF Research Database (Denmark)

    Kopacz, Csaba; Spataru, Sergiu; Sera, Dezso

    2014-01-01

    the inverters within each PV plant. The monitoring software stores the PV measurements in a data warehouse optimized for managing and data mining large amounts of data, from where it can be later visualized, analyzed and exported. By combining PV production measurements data with I-V curve measurements......This paper presents the concept and operating principles of a low-cost and flexible monitoring system for PV plants. Compared to classical solutions which can require dedicated hardware and/or specialized data logging systems, the monitoring system we propose allows parallel monitoring of PV plants...

  17. PV_LIB Toolbox v. 1.3

    Energy Technology Data Exchange (ETDEWEB)

    2015-12-09

    PV_LIB comprises a library of Matlab? code for modeling photovoltaic (PV) systems. Included are functions to compute solar position and to estimate irradiance in the PV system’s plane of array, cell temperature, PV module electrical output, and conversion from DC to AC power. Also included are functions that aid in determining parameters for module performance models from module characterization testing. PV_LIB is open source code primarily intended for research and academic purposes. All algorithms are documented in openly available literature with the appropriate references included in comments within the code.

  18. On Distributed PV Hosting Capacity Estimation, Sensitivity Study, and Improvement

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry

    2017-07-01

    This paper first studies the estimated distributed PV hosting capacities of seventeen utility distribution feeders using the Monte Carlo simulation based stochastic analysis, and then analyzes the sensitivity of PV hosting capacity to both feeder and photovoltaic system characteristics. Furthermore, an active distribution network management approach is proposed to maximize PV hosting capacity by optimally switching capacitors, adjusting voltage regulator taps, managing controllable branch switches and controlling smart PV inverters. The approach is formulated as a mixed-integer nonlinear optimization problem and a genetic algorithm is developed to obtain the solution. Multiple simulation cases are studied and the effectiveness of the proposed approach on increasing PV hosting capacity is demonstrated.

  19. Technologies to Increase PV Hosting Capacity in Distribution Feeders

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei; Mather, Barry; Gotseff, Peter

    2016-11-14

    This paper studies the distributed photovoltaic (PV) hosting capacity in distribution feeders by using the stochastic analysis approach. Multiple scenario simulations are conducted to analyze several factors that affect PV hosting capacity, including the existence of voltage regulator, PV location, the power factor of PV inverter and Volt/VAR control. Based on the conclusions obtained from simulation results, three approaches are then proposed to increase distributed PV hosting capacity, which can be formulated as the optimization problem to obtain the optimal solution. All technologies investigated in this paper utilize only existing assets in the feeder and therefore are implementable for a low cost. Additionally, the tool developed for these studies is described.

  20. Voltage rise mitigation for solar PV integration at LV grids

    DEFF Research Database (Denmark)

    Yang, Guangya; Marra, Francesco; Juamperez Goñi, Miguel Angel

    2015-01-01

    Solar energy from photovoltaic (PV) is among the fastest developing renewable energy systems worldwide. Driven by governmental subsidies and technological development, Europe has seen a fast expansion of solar PV in the last few years. Among the installed PV plants, most of them are situated...... at the distribution systems and bring various operational challenges such as power quality and power flow management. The paper discusses the modelling requirements for PV system integration studies, as well as the possible techniques for voltage rise mitigation at low voltage (LV) grids for increasing PV penetration...

  1. Design of A Pv/Diesel Stand Alone Hybrid System For A Remote Community in Palestine

    OpenAIRE

    Ismail, M.S.; Moghavvemi, M.; T.M.I. Mahlia

    2012-01-01

    Hybrid system based on photovoltaic is considered an effective option to electrify remote and isolated areas far from grid. This is true for areas that receive high averages of solar radiation annually. Using diesel generator as a standby source will make utilization of hybrid systems more attractive. An economic feasibility study and a complete design of a hybrid system consisting of photovoltaic (PV) panels, a diesel generator as a backup power source and a battery system supplying a small ...

  2. The Comprehensive Study of Electrical Faults in PV Arrays

    Directory of Open Access Journals (Sweden)

    M. Sabbaghpur Arani

    2016-01-01

    Full Text Available The rapid growth of the solar industry over the past several years has expanded the significance of photovoltaic (PV systems. Fault analysis in solar photovoltaic (PV arrays is a fundamental task to increase reliability, efficiency, and safety in PV systems and, if not detected, may not only reduce power generation and accelerated system aging but also threaten the availability of the whole system. Due to the current-limiting nature and nonlinear output characteristics of PV arrays, faults in PV arrays may not be detected. In this paper, all possible faults that happen in the PV system have been classified and six common faults (shading condition, open-circuit fault, degradation fault, line-to-line fault, bypass diode fault, and bridging fault have been implemented in 7.5 KW PV farm. Based on the simulation results, both normal operational curves and fault curves have been compared.

  3. Optimal Design of Modern Transformerless PV Inverter Topologies

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during...... the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inverter design variables are derived for each PV inverter topology and installation site. The H5, H6, neutral point...... clamped, active-neutral point clamped and conergy-NPC PV inverters designed using the proposed optimization process feature lower levelized cost of generated electricity and lifetime cost, longer mean time between failures and inject more PV-generated energy into the electric grid than their nonoptimized...

  4. Science Letters:Differentiation of xanthomonads causing the bacterial leaf spot of poinsettia in China from the pathotype strain of Xanthomonas axonopodis pv. Poinsettiicola

    Institute of Scientific and Technical Information of China (English)

    LI Bin; XIE Guan-lin; SWINGS J.

    2005-01-01

    In October 2003, a new bacterial disease with symptoms similar to those caused by Xanthomonas axonopodis pv.poinsettiicola was observed on poinsettia leaves at a flower nursery in Zhejiang Province of China. Three Xanthomonas strains were isolated from infected plants and classified as X. axonopodis. They were differentiated from the pathotype strain LMG849 of X. axonopodis pv. poinsettiicola causing bacterial leaf spot of poinsettia by comparison of pathogenicity, substrate utilization and BOX-PCR genomic fingerprints.

  5. Development of a dispatchable PV peak shaving system. Final report on PV:BONUS Phase 2 activities

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, W.D. [Conectiv, Inc., Wilmington, DE (United States); Nigro, R.M. [Applied Energy Group, Inc., Hauppauge, NY (United States)

    1999-01-20

    In July 1993, the Delmarva Power and Light Company (now Conectiv, Inc.) was awarded a contract for the development of a Dispatchable Photovoltaic Peak Shaving System under the US Department of Energy PV:BONUS Program. The rationale for the dispatchable PV peak shaving system is based on the coincidence between the solar resource and the electrical load in question. Where poor coincidence exists, a PV array by itself does little to offset peak demands. However, with the addition of a relatively small amount of energy storage, the energy from the PV array can be managed and the value of the PV system increases substantially. In Phase 2, Delmarva Power continued the refinement of the system deployed in Phase 1. Four additional dispatchable PV peak shaving systems were installed for extended testing and evaluation at sites in Delaware, Maryland, Wisconsin and North Carolina. A second type of system that can be used to provide back-up power as well as peak shaving was also developed in Phase 2. This PV-UPS system used a packaging approach nearly identical to the PV peak shaving system, although there were significant differences in the design of the power electronics and control systems. Conceptually, the PV-UPS system builds upon the idea of adding value to PV systems by increasing functionality. A prototype of the PV-UPS system was installed in Delaware for evaluation near the end of the contract period.

  6. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  7. Modular Power Converters for PV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL

    2012-05-01

    This report describes technical opportunities to serve as parts of a technological roadmap for Shoals Technologies Group in power electronics for PV applications. There are many different power converter circuits that can be used for solar inverter applications. The present applications do not take advantage of the potential for using common modules. We envision that the development of a power electronics module could enable higher reliability by being durable and flexible. Modules would have fault current limiting features and detection circuits such that they can limit the current through the module from external faults and can identify and isolate internal faults such that the remaining modules can continue to operate with only minimal disturbance to the utility or customer. Development of a reliable, efficient, low-cost, power electronics module will be a key enabling technology for harnessing more power from solar panels and enable plug and play operation. Power electronics for computer power supplies, communication equipment, and transportation have all targeted reliability and modularity as key requirements and have begun concerted efforts to replace monolithic components with collections of common smart modules. This is happening on several levels including (1) device level with intelligent control, (2) functional module level, and (3) system module. This same effort is needed in power electronics for solar applications. Development of modular units will result in standard power electronic converters that will have a lower installed and operating cost for the overall system. These units will lead to increased adaptability and flexibility of solar inverters. Incorporating autonomous fault current limiting and reconfiguration capabilities into the modules and having redundant modules will lead to a durable converter that can withstand the rigors of solar power generation for more than 30 years. Our vision for the technology roadmap is that there is no need

  8. Energy balance of the global photovoltaic (PV) industry--is the PV industry a net electricity producer?

    Science.gov (United States)

    Dale, Michael; Benson, Sally M

    2013-04-02

    A combination of declining costs and policy measures motivated by greenhouse gas (GHG) emissions reduction and energy security have driven rapid growth in the global installed capacity of solar photovoltaics (PV). This paper develops a number of unique data sets, namely the following: calculation of distribution of global capacity factor for PV deployment; meta-analysis of energy consumption in PV system manufacture and deployment; and documentation of reduction in energetic costs of PV system production. These data are used as input into a new net energy analysis of the global PV industry, as opposed to device level analysis. In addition, the paper introduces a new concept: a model tracking energetic costs of manufacturing and installing PV systems, including balance of system (BOS) components. The model is used to forecast electrical energy requirements to scale up the PV industry and determine the electricity balance of the global PV industry to 2020. Results suggest that the industry was a net consumer of electricity as recently as 2010. However, there is a >50% that in 2012 the PV industry is a net electricity provider and will "pay back" the electrical energy required for its early growth before 2020. Further reducing energetic costs of PV deployment will enable more rapid growth of the PV industry. There is also great potential to increase the capacity factor of PV deployment. These conclusions have a number of implications for R&D and deployment, including the following: monitoring of the energy embodied within PV systems; designing more efficient and durable systems; and deploying PV systems in locations that will achieve high capacity factors.

  9. An Analysis of Open World PvP in LOTRO's PvMP as a Case Study for PvP Games

    Directory of Open Access Journals (Sweden)

    Toh Weimin

    2014-11-01

    Full Text Available This article focuses on the analysis of emergent gameplay, based on a case study of the author's subjective gameplay experience of Player versus Monster Player (PvMP in The Lord of the Rings Online (LOTRO. The argument presented here is that although there is a core system of Player versus Player (PvP which LOTRO shares with other online games, each type of online game has a specific kind of PvP system which attracts players to engage in the gameplay. For instance, the open world sandbox type of PvP attracts certain players to play in LOTRO's PvMP. One of the main aims of this study is thus to investigate some of the core systems of PvP gameplay in open world sandbox PvP. In this article, LOTRO is shown to offer unique opportunities for studying emergent gameplay in open world games, with particular relevance to PvP studies. Two of the core systems of PvP discussed include the design of the simple gameplay rules to support emergent gameplay, and the community's attitudes towards player's behaviours. The types of emergent gameplay discussed include free play versus negotiated fair play, the players' utilisation of strategies in open world PvP to support collaborative and competitive gameplay, and the changing dynamics of open ended gameplay. It is hoped that the analysis provided in this article would form the­ basis of future work on a more general framework for understanding PvP in other online games.

  10. Numerical study of PV/T-SAHP system

    Institute of Scientific and Technical Information of China (English)

    Gang PEI; Jie JI; Ke-liang LIU; Han-feng HE; Ai-guo JIANG

    2008-01-01

    In order to utilize solar energy effectively and to achieve a higher electrical efficiency by limiting the operating temperature of the photovoltaic (PV) panel, a novel photovoltaic/thermal solar-assisted heat pump (PV/T-SAHP) system was proposed and constructed. The hybrid solar system generates electricity and thermal energy simultaneously. A distributed parameters model of the PV/T-SAHP system was developed and applied to analyze the system dynamic performance in terms of PV action, photothermal action and Rankine cycle processes. The simulation results indicated that the coefficient of performance (COP) of the proposed PV/T-SAHP can be much better than that of the conventional heat pump. Both PV-efficiency and photothermic efficiency have been improved considerably. The results also showed that the performance of this PV/T-SAHP system was strongly influenced by the evaporator area, tube pitch and tilt angle of the PV/T evaporator, which are the key factors in PV/T-SAHP system optimization and PV/T evaporator design.

  11. PV solar electricity: status and future

    Science.gov (United States)

    Hoffmann, Winfried

    2006-04-01

    Within the four main market segments of PV solar electricity there are already three areas competitive today. These are off-grid industrial and rural as well as consumer applications. The overall growth within the past 8 years was almost 40 % p.a. with a "normal" growth of about 18 % p.a. for the first three market segments whereas the grid connected market increased with an astonishing 63 % p.a. The different growth rates catapulted the contribution of grid connected systems in relation to the total market from about one quarter 6 years ago towards more than three quarters today. The reason for this development is basically due to industry-politically induced market support programs in the aforementioned countries. It is quite important to outline under which boundary conditions grid connected systems will be competitive without support programs like the feed in tariff system in Germany, Spain and some more to come in Europe as well as investment subsidies in Japan, US and some other countries. It will be shown that in a more and more liberalized utility market worldwide electricity produced by PV solar electricity systems will be able to compete with their generating cost against peak power prices from utilities. The point of time for this competitiveness is mainly determined by the following facts: 1. Price decrease for PV solar electricity systems leading to an equivalent decrease in the generated cost for PV produced kWh. 2. Development of a truly liberalized electricity market. 3. Degree of irradiation between times of peak power demand and delivery of PV electricity. The first topic is discussed using price experience curves. Some explanations will be given to correlate the qualitative number of 20 % price decrease for doubling cumulative worldwide sales derived from the historic price experience curve with a more quantitative analysis based on our EPIA-Roadmap (productivity increase and ongoing improvements for existing technologies as well as development

  12. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T) system against conventional photovoltaic (PV) system

    OpenAIRE

    2015-01-01

    Photovoltaic (PV) semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T) panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the...

  13. PV/T slates - Application examples and case studies; PV/T-Schiefer. Anwendungsbeispiele und Fallstudien

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report presents possible applications for PV/T slates based on data from the production atlas presented in another report in this series. Application variants are discussed, including hot-water preparation, air pre-heating, air-water heat pumps, buried seasonal storage and latent seasonal heat storage. Detailed examples are given for a hotel in Lugano, Switzerland and a residential estate in Davos.

  14. Vibrio vulnificus phage PV94 is closely related to temperate phages of V. cholerae and other Vibrio species.

    Science.gov (United States)

    Pryshliak, Mark; Hammerl, Jens A; Reetz, Jochen; Strauch, Eckhard; Hertwig, Stefan

    2014-01-01

    Vibrio vulnificus is an important pathogen which can cause serious infections in humans. Yet, there is limited knowledge on its virulence factors and the question whether temperate phages might be involved in pathogenicity, as is the case with V. cholerae. Thus far, only two phages (SSP002 and VvAW1) infecting V. vulnificus have been genetically characterized. These phages were isolated from the environment and are not related to Vibrio cholerae phages. The lack of information on temperate V. vulnificus phages prompted us to isolate those phages from lysogenic strains and to compare them with phages of other Vibrio species. In this study the temperate phage PV94 was isolated from a V. vulnificus biotype 1 strain by mitomycin C induction. PV94 is a myovirus whose genome is a linear double-stranded DNA of 33,828 bp with 5'-protruding ends. Sequence analysis of PV94 revealed a modular organization of the genome. The left half of the genome comprising the immunity region and genes for the integrase, terminase and replication proteins shows similarites to V. cholerae kappa phages whereas the right half containing genes for structural proteins is closely related to a prophage residing in V. furnissii NCTC 11218. We present the first genomic sequence of a temperate phage isolated from a human V. vulnificus isolate. The sequence analysis of the PV94 genome demonstrates the wide distribution of closely related prophages in various Vibrio species. Moreover, the mosaicism of the PV94 genome indicates a high degree of horizontal genetic exchange within the genus Vibrio, by which V. vulnificus might acquire virulence-associated genes from other species.

  15. Vibrio vulnificus phage PV94 is closely related to temperate phages of V. cholerae and other Vibrio species.

    Directory of Open Access Journals (Sweden)

    Mark Pryshliak

    Full Text Available BACKGROUND: Vibrio vulnificus is an important pathogen which can cause serious infections in humans. Yet, there is limited knowledge on its virulence factors and the question whether temperate phages might be involved in pathogenicity, as is the case with V. cholerae. Thus far, only two phages (SSP002 and VvAW1 infecting V. vulnificus have been genetically characterized. These phages were isolated from the environment and are not related to Vibrio cholerae phages. The lack of information on temperate V. vulnificus phages prompted us to isolate those phages from lysogenic strains and to compare them with phages of other Vibrio species. RESULTS: In this study the temperate phage PV94 was isolated from a V. vulnificus biotype 1 strain by mitomycin C induction. PV94 is a myovirus whose genome is a linear double-stranded DNA of 33,828 bp with 5'-protruding ends. Sequence analysis of PV94 revealed a modular organization of the genome. The left half of the genome comprising the immunity region and genes for the integrase, terminase and replication proteins shows similarites to V. cholerae kappa phages whereas the right half containing genes for structural proteins is closely related to a prophage residing in V. furnissii NCTC 11218. CONCLUSION: We present the first genomic sequence of a temperate phage isolated from a human V. vulnificus isolate. The sequence analysis of the PV94 genome demonstrates the wide distribution of closely related prophages in various Vibrio species. Moreover, the mosaicism of the PV94 genome indicates a high degree of horizontal genetic exchange within the genus Vibrio, by which V. vulnificus might acquire virulence-associated genes from other species.

  16. PV shading device integrated system in a University Building in Italy

    OpenAIRE

    2004-01-01

    PV Enlargement project PV Enlargement" boldly demonstrates Europe’s commitment for improved energy efficiency and cost-effectiveness of PV systems, enhancing the development of large European PV markets. The project can be subdivided into three major fields of activities: Demonstration (1,218 kWp) of highly cost-effective or very innovative PV technologies in 10 European countries for increasing public awareness about and visibility of PV solar electricity Transfer of PV Technol...

  17. PV/T slates - Production atlas; PV/T-Schiefer. Ertragsatlas

    Energy Technology Data Exchange (ETDEWEB)

    Kropf, S.

    2003-07-01

    This illustrated report for the Swiss Federal Office of Energy (SFOE) is one a series of five reports dealing with increasing the overall efficiency of photovoltaic (PV) installations by also using the heat collected by the dark-coloured PV panels. The work reported on addresses open questions on the use of the heat and its optimal use. This report first deals with the dynamic building simulation system IDA and goes on to present an appendix that lists the results for the three climatic locations Zurich, Lugano and Davos in detail. The results are calculated for various seasons, orientations, mounting angles, air-flow rates and temperature differences.

  18. Testing to Support Improvements to PV Components and Systems

    Energy Technology Data Exchange (ETDEWEB)

    THOMAS,H.; KROPOSKI,B.; WITT,C.; BOWER,WARD I.; BONN,RUSSELL H.; GINN,JERRY W.; GONZALEZ,SIGIFREDO

    2000-07-15

    The National Photovoltaic (PV) Program is sponsored by the US Department of Energy and includes a PV Manufacturing Research and Development (R and D) project conducted with industry. This project includes advancements in PV components to improve reliability, reduce costs, and develop integrated PV systems. Participants submit prototypes, pre-production hardware products, and examples of the resulting final products for a range of tests conducted at several national laboratories, independent testing laboratories, and recognized listing agencies. The purpose of this testing is to use the results to assist industry in determining a product's performance and reliability, and to identify areas for potential improvement. This paper briefly describes the PV Manufacturing R and D project, participants in the area of PV systems, balance of systems, and components, and several examples of the different types of product and performance testing used to support and confirm product performance.

  19. PV technology and success of solar electricity in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Dung, T.Q. [Vietnam National Center for Science and Technology, Ho Chi Minh City (Viet Nam). Solarlab

    1997-12-31

    Since 1990 the PV Technology and the Solar electricity have been strongly developed in Vietnam. The PV experts of Solarlab have studied and set up an appropriate PV Technology responding to local Market needs. It has not only stood well but has been also transferred to Mali Republic and Lao P.D.R. The PV off grid systems of Solarlab demonstrate good efficiency and low prices. Over 60 solar stations and villages have been built to provide solar lighting for about 3000 families along the country in remote, mountainous areas and islands. 400 families are using stand-alone Solar Home Systems. The Solar electricity has been chosen for Rural Electrification and National Telecommunication Network in remote and mountainous regions. Many International projects in cooperation with FONDEM-France, SELF USA and Governmental PV projects have been realized by Solarlab. The experiences of maintenance, management and finance about PV development in Vietnam are also mentioned.

  20. Isolation and molecular characterization of polyvinyl chloride (PVC) plastic degrading fungal isolates.

    Science.gov (United States)

    Ali, Muhammad Ishtiaq; Ahmed, Safia; Robson, Geoff; Javed, Imran; Ali, Naeem; Atiq, Naima; Hameed, Abdul

    2014-01-01

    The recalcitrant nature of polyvinyl chloride creates serious environmental concerns during manufacturing and waste disposal. The present study was aimed to isolate and screen different soil fungi having potential to biodegrade PVC films. After 10 months of soil burial experiment, it was observed that a number of fungal strains were flourishing on PVC films. On morphological as well as on 18rRNA gene sequence and phylogenetic basis they were identified as Phanerochaete chrysosporium PV1, Lentinus tigrinus PV2, Aspergillus niger PV3, and Aspergillus sydowii PV4. The biodegradation ability of these fungal isolates was further checked in shake flask experiments by taking thin films of PVC (C source) in mineral salt medium. A significant change in color and surface deterioration of PVC films was confirmed through visual observation and Scanning electron microscopy. During shake flask experiments, P. chrysosporium PV1 produced maximum biomass of about 2.57 mg ml(-1) followed by A. niger PV3. P. chrysosporium PV1 showed significant reduction (178,292 Da(-1)) in Molecular weight of the PVC film than control (200,000 Da(-1)) by gel permeation chromatography. Furthermore more Fourier transform infrared spectroscopy and nuclear magnetic resonance also revealed structural changes in the PVC. It was concluded that isolated fungal strains have significant potential for biodegradation of PVC plastics.

  1. Growth deficiency of a Xanthomonas oryzae pv. oryzae fur mutant in rice leaves is rescued by ascorbic acid supplementation.

    Science.gov (United States)

    Subramoni, Sujatha; Sonti, Ramesh V

    2005-07-01

    Xanthomonas oryzae pv. oryzae causes bacterial leaf blight, a serious disease of rice. A mutation was isolated in the ferric uptake regulator (fur) gene of X. oryzae pv. oryzae and it was shown to result in the production of siderophores in a constitutive manner. The fur mutant is hypersensitive to the metallo-antibiotic streptonigrin, a phenotype that is indicative of intracellular free-iron overload, and also exhibits a slow growth phenotype on rich medium. The fur mutant is virulence deficient, hypersensitive to hydrogen peroxide, and exhibits reduced catalase activity. Exogenous supplementation with ascorbic acid (an antioxidant) rescues the growth deficiency of the fur mutant in rice leaves. The virulence deficiency of the X. oryzae pv. oryzae fur mutant is proposed to be due, at least in part, to an impaired ability to cope with the oxidative stress conditions that are encountered during infection.

  2. PV window - Development and demonstrations. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haugaard, P.

    2011-05-15

    Using the results from the EU project RenewTransnet, which focused on the development of a pane with integrated solar cells, the goal of this project is to develop these principles into a window solution. This window solution is targeted to Danish building tradition and architecture. It is expected that an elegant PV-window solution for both new and retrofit buildings is developed during this project, and which appearance can be customized to each building. Based on results from a related projects carried out by Gaia Solar, the window solution will have the potential of being approximately 30% cheaper than similar products on the market. In this project this price reduction is the objective of the development of a window solution. The project team has succeeded in developing a 2-layer PV-window with glass / glass lamination with EVA as foil, which is 35% cheaper than similar products on the market. Since the price for the frame-profile does not differ significantly at market level, the price comparison is made on the basis of the developed PV-pane. The objective of 30 % price reduction in relation to similar products on the market is met. A special production process to the making glass/glass lamination with EVA as foil has been developed, in which a frame is put around the module which intends both to remove the unwanted tension along the edges, and to prevent the significant spillage of EVA from the module under pressure and prevent the invasive bubbles along the edge of module. Since the developed production method for making glass/glass modules with EVA is simple, a further cost reduction will primarily be in a reduction of the price of the cell. The project process has resulted in the development of a product, which due to continuous restrictions in the building regulations, will be very attractive in future buildings. (LN)

  3. PV modules without bypass diodes; PV-Module ohne Bypass-Dioden? - Untersuchungen an einer PV-Fassade

    Energy Technology Data Exchange (ETDEWEB)

    Laukamp, H.; Kresse, A.; Leithold, W. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany)]|[Ingenieurbuero A. Kresse, Karlsruhe (Germany)]|[Solare Systemtechnik GmbH, Freiburg (Germany)

    1998-12-01

    In order to protect solar modules against high output losses with non-homogeneous irradiation, bypass diodes which are mostly accommodated in the module connection socket are used. One would often gladly dispense with these connection sockets for integration of customer-specific large modules in facades. The question: ``Where will the diodes go?`` must then be satisfactorily answered. Both laminating the diodes in the module and their external accommodation cause extra expense elsewhere. It would be ideal if one could dispense with the bypass diodes altogether. This article tries to answer the question, in what conditions this is possible. Starting from the PV facade `Freiburg solar centre`, where one dispensed with the protective diodes, investigations are carried out experimentally and by means of simulation calculations. [Deutsch] Um Solarmodule bei inhomogener Bestrahlung vor hohen Verlustleistungen zu schuetzen, werden ueblicherweise Bypass-Dioden eingesetzt, die zumeist in der Modulanschlussdose untergebracht sind. Zur Fassadenintegration von kundenspezifischen Grossmodulen wuerde man manchmal gerne auf die Anschlussdosen verzichten. Hierfuer muesste zunaechst die Frage `wohin mit den Dioden?` befriedigend beantwortet werden. Sowohl die Einlaminierung der Dioden in das Modul, als auch deren externe Unterbringung versursachen an anderer Stelle einen erhoehten Aufwand. Ideal waere es, wenn man auf die Bypass-Dioden ganz verzichten koennte. Die vorliegende Arbeit versucht die Frage zu beantworten, unter welchen Bedingungen dies moeglich ist. Ausgehend von der PV-Fassade `Solarzentrum Freiburg` - hier wurde auf den Einsatz von Schutzdioden verzichtet - werden experimentell und mittels Simulationsrechnungen Untersuchungen durchgefuehrt. (orig./RHM)

  4. Impact of Rooftop Solar PV on Residential Distribution Network

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Pillai, Jayakrishnan Radhakrishna

    Increased environmental awareness in recent years has encouraged rapid growth of renewable energy sources especially solar PV and wind. Among them, small scale solar PV has been gaining more momentum especially at residential level. Even today moderate penetration of grid tied rooftop solar PV has...... become reality in many countries. In spite of various benefits, higher penetration of rooftop PVs might come up with number of detrimental effects, with power quality and overcurrent protection being the major ones. Therefore, it is reasonable to quantify both drawback and benefits of rooftop PV...

  5. Solar Energy: Incentives to Promote PV in EU27

    Directory of Open Access Journals (Sweden)

    María del P. Pablo-Romero

    2013-11-01

    Full Text Available The growth in the use of renewable energies in the EU has been remarkable. Among these energies is PV. The average annual growth rate for the EU-27 countries in installed PV capacity in the period 2005-2012 was 41.2%. While the installed capacity of PV has reached almost 82 % of National Renewable Energy Action Plan (NREAP targets for the EU-27 countries for 2020, it is still far from being used at its full potential. Over recent years, several measures have been adopted in the EU to enhance and promote PV. This paper undertakes a complete review of the state of PV power in Europe and the measures taken to date to promote it in EU-27. 25 countries have adopted measures to promote PV. The most widespread measure to promote PV use is Feed- in Tariffs. Tariffs are normally adjusted, in a decreasing manner, annually. Nevertheless, currently, seven countries have decided to accelerate this decrease rate in view of cost reduction of the installations and of higher efficiencies. The second instrument used to promote PV in the EU-27 countries is the concession of subsidies. Nevertheless, subsidies have the disadvantage of being closely linked to budgetary resources and therefore to budgetary constraints. In most EU countries, subsidies for renewable energy for PV are being lowered. Twelve EU-27 countries adopted tax measures. Low-interest loans and green certificate systems were only sparingly used.

  6. Fault Analysis and Detection in Microgrids with High PV Penetration

    Energy Technology Data Exchange (ETDEWEB)

    El Khatib, Mohamed [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hernandez Alvidrez, Javier [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    In this report we focus on analyzing current-controlled PV inverters behaviour under faults in order to develop fault detection schemes for microgrids with high PV penetration. Inverter model suitable for steady state fault studies is presented and the impact of PV inverters on two protection elements is analyzed. The studied protection elements are superimposed quantities based directional element and negative sequence directional element. Additionally, several non-overcurrent fault detection schemes are discussed in this report for microgrids with high PV penetration. A detailed time-domain simulation study is presented to assess the performance of the presented fault detection schemes under different microgrid modes of operation.

  7. Evaluation of a solar PV tracking prototype on tropic regions

    Directory of Open Access Journals (Sweden)

    Cristian Manuel Agudelo Restrepo

    2016-06-01

    Full Text Available Nowadays climate change is a big concern for human society, due to our high dependence on fossil fuels. A great amount of research effort is focused in solar photovoltaic (PV systems, particularly on the improvement of the conversion efficiency. One technique commonly used is the tracking systems, where the solar PV moves with the sun in order to capture the maximum direct solar radiation. This paper presents a solar PV single-axis tracking system prototype, and a comparison regarding its energy conversion efficiency with a fixed solar PV installation. The system was tested in Fusagasugá, Colombia, which is located in the tropics region.

  8. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  9. A minimum achievable PV electrical generating cost

    Energy Technology Data Exchange (ETDEWEB)

    Sabisky, E.S. [11 Carnation Place, Lawrenceville, NJ 08648 (United States)

    1996-03-22

    The role and share of photovoltaic (PV) generated electricity in our nation`s future energy arsenal is primarily dependent on its future production cost. This paper provides a framework for obtaining a minimum achievable electrical generating cost (a lower bound) for fixed, flat-plate photovoltaic systems. A cost of 2.8 $cent/kWh (1990$) was derived for a plant located in Southwestern USA sunshine using a cost of money of 8%. In addition, a value of 22 $cent/Wp (1990$) was estimated as a minimum module manufacturing cost/price

  10. Ancillary services provided by PV power plants

    Directory of Open Access Journals (Sweden)

    Antonio PIERNO

    2016-07-01

    Full Text Available Renewable energy sources are widely utilized in distributed generation systems, and, recently, they are also considered for providing ancillary services. The paper is focused on PV plants, a survey of the most interesting papers published in the literature in the last decade is reported and the main characteristics of the technical proposals, with their advantages and limits, are evidenced. The results are schematically shown in a table that immediately gives the opportunity to be aware of what was already done, representing a reference tool.

  11. Integrating Solar PV in Utility System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved

  12. Experimental investigation of PV modules recycling; PV module recycle no jikkenteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Unagida, H.; Kurokawa, K. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Sakuta, K.; Otani, K.; Murata, K. [Electrotechnical Laboratory, Tsukuba (Japan)

    1997-11-25

    Recycling, cost/energy analysis and recovery experiment were made on crystalline silicon PV modules with EVA(ethylene vinyl acetate)-laminated structure. The life of modules is dependent not on performance deterioration of PV cells themselves but on yellowing or poor transmittance of EVA caused by ultraviolet ray, and disconnection between cells by thermal stress. Recovery is carried out in 3 stages of cell, wafer and material. Recovery in the stages of cell and wafer results in considerable reduction of energy and cost. The recovery experiment was carried out using PV module samples prepared by cutting the modules into 25times15mm pieces after removing Al frames from the used modules, peeling back sheets and cutting off EVA. Since a nitric acid process at 70-80degC can dissolve EVA effectively, it is promising for reuse of surface glass and PV cells as they are. This process is also carried out under a condition around room temperature and pressure, contributing to cost reduction and energy saving for recycling. Generation of harmful NOx is only a problem to be solved. 2 refs., 6 figs., 1 tab.

  13. Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    None

    1995-10-01

    This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

  14. Hybrid PV/wind system with quinary asymmetric inverter without increasing DC-link number

    Directory of Open Access Journals (Sweden)

    Aida Baghbany Oskouei

    2016-06-01

    Full Text Available This paper suggests quinary asymmetric inverter with coupled inductors and transformer, and uses it in hybrid system including photovoltaic (PV and wind. This inverter produces twenty-five-level voltage in addition to merits of multilevel inverter, has only one DC source. Then, it is adequate for hybrid systems, which prevents increasing DC-link and makes control of system easy. Proposed structure also provides isolation in the system and the switch numbers are reduced in this topology compared with other multilevel structures. In this system, battery is used as backup, where PV and wind have complementary nature. The performance of proposed inverter and hybrid system is validated with simulation results using MATLAB/SIMULINK software and experimental results based PCI-1716 data acquisition system.

  15. Simulation of Power Produced by a Building Added PV System in Indonesia using virtual reality

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    In this study a PV system will be simulated using virtual reality software for PV system simulations -called VR4PV - to show the effectiveness of the modelling of PV systems on buildings which are placed in the tropics. The PV system used for this study has been installed in Papua, Indonesia and inc

  16. Demonstration of Active Power Controls by Utility-Scale PV Power Plant in an Island Grid: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, Vahan; O' Neill, Barbara

    2017-02-01

    The National Renewable Energy Laboratory (NREL), AES, and the Puerto Rico Electric Power Authority conducted a demonstration project on a utility-scale photovoltaic (PV) plant to test the viability of providing important ancillary services from this facility. As solar generation increases globally, there is a need for innovation and increased operational flexibility. A typical PV power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. In this way, it may mitigate the impact of its variability on the grid and contribute to important system requirements more like traditional generators. In 2015, testing was completed on a 20-MW AES plant in Puerto Rico, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to provide various types of new grid-friendly controls. This data showed how active power controls can leverage PV's value from being simply an intermittent energy resource to providing additional ancillary services for an isolated island grid. Specifically, the tests conducted included PV plant participation in automatic generation control, provision of droop response, and fast frequency response.

  17. Projecting of PV facades in consideration of PV-specific operating conditions; Besonderheiten bei der Projektierung von Photovoltaik-Fassadenanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Decker, B.; Grimmig, B.; Mencke, D. [Institut fuer Solarenergieforschung GmbH Hameln/Emmerthal (ISFH), Emmerthal (Germany). Gruppe Photovoltaik-Systeme; Stellbogen, D. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany). Fachgebiet Photovoltaische Anlagentechnik

    1998-02-01

    PV facades can provide several additional functions such as weather protection, thermal insulation, daylighting or sun protection. On the other hand, specific operating conditions for PV facades must be taken into account when selecting components and designing the system. Depending on ventilation conditions, there is a large range of maximum module temperatures. South-oriented PV facades receive about 30% less yearly irradiation than an optimally inclined PV generator, hence reflection losses are approximately 4% higher. The maximum of yearly irradiation lies only in the 400-600 W/m{sup 2} range. Surrounding buildings and/or vegetation can impair performance of the PV-facades. For a south-oriented PV facade an annual yield in the range of 470-560 kwh/kW{sub p}.a has been prodicted which was verified by operating results of eight PV facades. (orig.) [Deutsch] Photovoltaik (PV) Fassaden ermoeglichen neben der Stromerzeugung zusaetzliche Funktionen wie Wetterschutz bzw. Waermedaemmung des Gebaeudes oder Tageslichtnutzung bzw. Sonnenschutz der Innenraeume. Allerdings muessen fassadenspezifische Betriebsbedingungen, bei der Komponentenauswahl und Systemauslegung beruecksichtigt werden. Unterschiedliche Hinterlueftungsbedingungen fuehren zu einer grossen Bandbreite der maximalen Modultemperatur. PV-Suedfassaden empfangen etwa 30% weniger Jahreseinstrahlung als ein optimal geneigter PV-Generator. Die Haelfte der jaehrlichen Einstrahlung trifft mit Einfallswinkeln groesser 50 auf die vertikal angeordneten Module wodurch die Reflexionsverluste um ca. 4% hoeher sind. Das Maximum der Jahreseinstrahlung liegt nur um 400-600 W/m{sup 2} und erreicht selten Werte ueber 800 W/m{sup 2}. Umliegende Gebaeude oder Vegetation koennen zu Teilabschattungen des Generators fuehren. Fuer eine vertikale PV-Suedfassade wird ein Jahresenergieertrag in Hoehe von 470-560 kWh/kW{sub p}.a prognostiziert, der anhand der Betriebsergebnisse von acht PV-Fassadenanlagen verifiziert werden konnte

  18. Overview of PV Wind hybrid system activities in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Bopp, G.; Gabler, H.; Kiefer, K.; Preiser, K.; Wiemken, E. [Fraunhofer Institute for Solar Energy Systems ISE, Freiburg (Germany)

    1997-12-31

    Photovoltaic solar generators combined with diesel engines, in some cases additionally with wind energy converters, and battery energy storage are powering isolated mountain lodges, information centers in nature parks, isolated farms or dwellings all over Europe. A total of 300,000 buildings in Europe are estimated to be not connected to the public grid. This represents a major market potential for photovoltaic, as often photovoltaic power generation is less expensive than a connection to the electric utility. The Fraunhofer Institute for Solar Energy Systems ISE has planned, realized and monitored about 30 hybrid remote energy supply systems with PV generators typically around 5 kW for loads typically around 20 kWh per day. More than one hundred years of operational experience accumulated so far, are a sound foundation on which to draw an interim balance over problems solved and technical questions still under development. Room for further technical development is seen in the domain of system reliability and the reduction of operating costs as well as in the optimization of the utilization of the electric energy produced by the PV generator. [Espanol] Para la electrificacion en toda Europa de casas de campo en la montana, centros de informacion, parques naturales, granjas aisladas o conjuntos habitacionales, se estan usando generadores fotovoltaicos combinados con maquinas diesel, en algunos casos adicionalmente con convertidores de energia del viento y baterias para el almacenamiento de energia. Se estima que en Europa un total de 300,000 edificios no estan conectados a la red publica. Esto representa un gran mercado potencial para los sistemas fotovoltaicos, ya que a menudo la generacion fotovoltaica es menos costosa que una conexion a la empresa electrica. El Instituto Fraunhofer para Sistemas de Energia Solar ISE ha planeado, llevado a cabo y monitoreado alrededor de 30 sistemas hibridos remotos de suministro de energia con generadores fotovoltaicos

  19. Oxynitride Thin Film Barriers for PV Packaging

    Energy Technology Data Exchange (ETDEWEB)

    Glick, S. H.; delCueto, J. A.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2005-11-01

    Dielectric thin-film barrier and adhesion-promoting layers consisting of silicon oxynitride materials (SiOxNy, with various stoichiometry) were investigated. For process development, films were applied to glass (TCO, conductive SnO2:F; or soda-lime), polymer (PET, polyethylene terephthalate), aluminized soda-lime glass, or PV cell (a-Si, CIGS) substrates. Design strategy employed de-minimus hazard criteria to facilitate industrial adoption and reduce implementation costs for PV manufacturers or suppliers. A restricted process window was explored using dilute compressed gases (3% silane, 14% nitrous oxide, 23% oxygen) in nitrogen (or former mixtures, and 11.45% oxygen mix in helium and/or 99.999% helium dilution) with a worst-case flammable and non-corrosive hazard classification. Method employed low radio frequency (RF) power, less than or equal to 3 milliwatts per cm2, and low substrate temperatures, less than or equal to 100 deg C, over deposition areas less than or equal to 1000 cm2. Select material properties for barrier film thickness (profilometer), composition (XPS/FTIR), optical (refractive index, %T and %R), mechanical peel strength and WVTR barrier performance are presented.

  20. National survey report on PV power applications in Switzerland 2006

    Energy Technology Data Exchange (ETDEWEB)

    Huesser, P. [Nova Energie GmbH, Aarau (Switzerland); Hostettler, T. [Ingenieurbuero Hostettler, Berne (Switzerland)

    2007-07-01

    This annual report was published by the Swiss Federal Office of Energy (SFOE) as part of the International Energy Agency's work on the exchange and dissemination of information on photovoltaic power systems (PVPS). The political situation in Switzerland with regard to the promotion of photovoltaics (PV) and new legislation in the energy area is discussed. The report provides information on installed PV power, costs and prices and the Swiss PV industry. Examples of PV applications are presented and data on the cumulative installed PV power in various application sectors is presented and discussed. Highlights, major projects and various demonstration and field-test programmes are dealt with, as are public budgets for market stimulation. Figures on the development, production and prices of PV cells and modules are presented. Swiss balance-of-system products are reviewed, as are PV-related services and the value of the Swiss PV business. A review of non-technical factors and new initiatives completes the report.

  1. Product integrated PV: the future is design and styling

    NARCIS (Netherlands)

    Eggink, Wouter; Reinders, Angèle

    2016-01-01

    In this paper we explore how PV powered products have been designed in the past. For this purpose we have drawn a historical time line of the design features of PV powered products in the context of main stream design and styling. Our time frame is 1970 till 2016, focusing in first instance on consu

  2. Energy requirements and CO2 mitigation potential of PV systems

    NARCIS (Netherlands)

    Alsema, E.A.

    2006-01-01

    In this paper we investigate the energy requirements of PV modules and systems and calculate the Energy Pay-Back Time for two major PV applications. Based on a review of past energy analysis studies we explain the main sources of differences and establish a "best estimate" for key system components.

  3. PV O&M Cost Model and Cost Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Andy

    2017-03-15

    This is a presentation on PV O&M cost model and cost reduction for the annual Photovoltaic Reliability Workshop (2017), covering estimating PV O&M costs, polynomial expansion, and implementation of Net Present Value (NPV) and reserve account in cost models.

  4. Applications of ``PV Optics`` for solar cell and module design

    Energy Technology Data Exchange (ETDEWEB)

    Sopori, B.L.; Madjdpour, J.; Chen, W. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    This paper describes some applications of a new optics software package, PV Optics, developed for the optical design of solar cells and modules. PV Optics is suitable for the analysis and design of both thick and thin solar cells. It also includes a feature for calculation of metallic losses related to contacts and back reflectors.

  5. Development of PV powered consumer products using future scenarios

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Meulen, van der B.J.R.; Eger, A.O.

    2006-01-01

    Given the high potential of PV technology to reduce the environmental impact of electricity use of consumer products, it would be worthwhile to advance the application of PV systems in mass produced products. To date this field of application has been explored only to a limited extent. For this reas

  6. Analysis of Long-Term Performance of PV Systems

    NARCIS (Netherlands)

    Nordmann, T.; Clavadetscher, L.; van Sark, Wilfried; Green, M.

    2015-01-01

    This report describes the activities, conclusions and continued efforts undertaken in Subtask 1 by the participating countries in IEA-PVPS Task 13. Subtask 1 examines the PV power plant as a system. It collects and studies the data supplied from installed operating PV plants from different countries

  7. Solar PV Energy Conversion System and its Configurations

    OpenAIRE

    Ahteshamul Haque

    2016-01-01

    Solar PV based energy conversion system is now used in commercial and residential buildings. Advancements in Power electronics leads the researchers to enhance the use of solar application in various configurations. These configurations may be used to utilize the energy optimally. The main objective of this paper is to present an overview of the various configurations of solar PV energy conversion system

  8. Genetic polymorphism and natural selection of Duffy binding protein of Plasmodium vivax Myanmar isolates.

    Science.gov (United States)

    Ju, Hye-Lim; Kang, Jung-Mi; Moon, Sung-Ung; Kim, Jung-Yeon; Lee, Hyeong-Woo; Lin, Khin; Sohn, Woon-Mok; Lee, Jin-Soo; Kim, Tong-Soo; Na, Byoung-Kuk

    2012-03-01

    Plasmodium vivax Duffy binding protein (PvDBP) plays an essential role in erythrocyte invasion and a potential asexual blood stage vaccine candidate antigen against P. vivax. The polymorphic nature of PvDBP, particularly amino terminal cysteine-rich region (PvDBPII), represents a major impediment to the successful design of a protective vaccine against vivax malaria. In this study, the genetic polymorphism and natural selection at PvDBPII among Myanmar P. vivax isolates were analysed. Fifty-four P. vivax infected blood samples collected from patients in Myanmar were used. The region flanking PvDBPII was amplified by PCR, cloned into Escherichia coli, and sequenced. The polymorphic characters and natural selection of the region were analysed using the DnaSP and MEGA4 programs. Thirty-two point mutations (28 non-synonymous and four synonymous mutations) were identified in PvDBPII among the Myanmar P. vivax isolates. Sequence analyses revealed that 12 different PvDBPII haplotypes were identified in Myanmar P. vivax isolates and that the region has evolved under positive natural selection. High selective pressure preferentially acted on regions identified as B- and T-cell epitopes of PvDBPII. Recombination may also be played a role in the resulting genetic diversity of PvDBPII. PvDBPII of Myanmar P. vivax isolates displays a high level of genetic polymorphism and is under selective pressure. Myanmar P. vivax isolates share distinct types of PvDBPII alleles that are different from those of other geographical areas. These results will be useful for understanding the nature of the P. vivax population in Myanmar and for development of PvDBPII-based vaccine.

  9. A global strategy for the European PV industry

    Energy Technology Data Exchange (ETDEWEB)

    Viaud, M.; Despotou, E.; Latour, M. [European Photovoltaic Industry Association (EPIA) secretariat, Brussels (Belgium); Hoffmann, W.; Macias, E.; Cameron, M.; Laborde, E. [European Photovoltaic Industry Association (EPIA), Brussels (Belgium)

    2004-07-01

    The objective was to develop a comprehensive strategy that answers to the need of today European PV industry. Namely: - Develop PV markets in Europe - Develop export markets. - Position the European PV industry within the European political environment and support the effort of national actors in their local objectives. This method lends itself to brainstorming to create actions and synergies, on order to achieve strategy objectives. The whole work is based on working groups clearly defined on the purpose, where all EPIA members are invited to participate. The overall first results are presented during the 19. EU PV Conference in Paris and EPIA will do recommendations on actions to be undertaken in the future. This strategy is co-financed by EPIA members and the 6. Framework Programme for research of the European Commission through the PV Catapult project. (authors)

  10. Optimum Design Of On Grid Pv System Using Tracking System

    Directory of Open Access Journals (Sweden)

    Saeed Mansour

    2015-05-01

    Full Text Available Abstract The fossil fuel is a main issue in the world due to the increase of fossil fuel cost and the depletion of the fossil fuel with continuous increasing demand on electricity. With continuous decrease of PV panels cost it is interesting to consider generation of electricity from PV system. To provide electric energy to a load in a remote area where electric grid utility is not available or connection with grid utility is available there are two approaches of photovoltaic system PV without tracking system Fixed System and PV with tracking systems. The result shows that the energy production by using PV with tracking system generates more energy in comparison with fixed panels system. However the cost per produced KWH is less in case of using fixed panels. This is the backbone in choice between two approaches of photovoltaic system. In this work a system design and cost analysis for two approaches of photovoltaic system are considered.

  11. Costs of Residential Solar PV Plants in Distribution Grid Networks

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Yang, Guangya; Ipsen, Hans Henrik

    2015-01-01

    In this article we investigate the impact of residential solar PV plants on energy losses in distribution networks and their impact on distribution transformers lifetime. Current guidelines in Denmark states that distribution transformers should not be loaded with more than 67% solar PV power...... to avoid accelerated loss of life. If a solar PV plant causes this limit to be exceeded, the particular owner has to pay for upgrading the transformer. Distribution Network Operators also charge an annual tariff from the solar PV plants to cover the expenses to keep the grid capacity available, the so...... called “Availability Tariff”. According to the Danish Energy Regulatory Authority, the Availability Tariff must cover the exact expenses, with energy savings etc. from the solar PV plants taken into consideration. Our conclusion is that a distribution network, which represents a typical residential...

  12. Overview of Recent Grid Codes for PV Power Integration

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2012-01-01

    and Distribution System Operators (DSOs) had to keep the safety and reliability of the network under strict rules and regulations. The aim of the paper is to realize a survey of recent Grid Codes (GC) and regulations for grid connected PV systems. The focus is on grid interface requirements, power quality concerns...... and Anti-Islanding (AI) issues regarding PV systems connected to low voltage (LV) and medium voltage (MV) levels of the network.......The challenge to bring down the cost of produced photovoltaic (PV) power had a major impact on the PV market and in consequence the grid operators experienced higher and higher PV power penetration. The growing share of this decentralized generation plants started to affect the grid stability...

  13. Fire hazard and other safety concerns of PV systems

    Science.gov (United States)

    Dhere, Neelkanth G.

    2011-09-01

    Photovoltaic modules are usually considered safe and reliable. But in case of grid-connected PV systems that are becoming very popular, the issue of fire safety of PV modules is becoming increasingly important due to the employed high voltages of 600 V to 1000 V. The two main factors i.e. open circuiting of the bypass diode and ground fault that are responsible for the fire in the PV systems have been discussed in detail along with numerous real life examples. Recommendations are provided for preventing the fire hazards such as having at least class C fire rated PV modules, proper bypass and blocking diodes and interestingly, having an ungrounded PV system.

  14. Codes, standards, and PV power systems. A 1996 status report

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, J

    1996-06-01

    As photovoltaic (PV) electrical power systems gain increasing acceptance for both off-grid and utility-interactive applications, the safety, durability, and performance of these systems gains in importance. Local and state jurisdictions in many areas of the country require that all electrical power systems be installed in compliance with the requirements of the National Electrical Code{reg_sign} (NEC{reg_sign}). Utilities and governmental agencies are now requiring that PV installations and components also meet a number of Institute of Electrical and Electronic Engineers (IEEE) standards. PV installers are working more closely with licensed electricians and electrical contractors who are familiar with existing local codes and installation practices. PV manufacturers, utilities, balance of systems manufacturers, and standards representatives have come together to address safety and code related issues for future PV installations. This paper addresses why compliance with the accepted codes and standards is needed and how it is being achieved.

  15. Costs of Residential Solar PV Plants in Distribution Grid Networks

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Yang, Guangya; Ipsen, Hans Henrik

    2015-01-01

    In this article we investigate the impact of residential solar PV plants on energy losses in distribution networks and their impact on distribution transformers lifetime. Current guidelines in Denmark states that distribution transformers should not be loaded with more than 67% solar PV power...... called “Availability Tariff”. According to the Danish Energy Regulatory Authority, the Availability Tariff must cover the exact expenses, with energy savings etc. from the solar PV plants taken into consideration. Our conclusion is that a distribution network, which represents a typical residential...... to avoid accelerated loss of life. If a solar PV plant causes this limit to be exceeded, the particular owner has to pay for upgrading the transformer. Distribution Network Operators also charge an annual tariff from the solar PV plants to cover the expenses to keep the grid capacity available, the so...

  16. Physical Effects of Distributed PV Generation on California's Distribution System

    CERN Document Server

    Cohen, Michael A

    2015-01-01

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  17. PV Performance Modeling Methods and Practices: Results from the 4th PV Performance Modeling Collaborative Workshop.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    In 2014, the IEA PVPS Task 13 added the PVPMC as a formal activity to its technical work plan for 2014-2017. The goal of this activity is to expand the reach of the PVPMC to a broader international audience and help to reduce PV performance modeling uncertainties worldwide. One of the main deliverables of this activity is to host one or more PVPMC workshops outside the US to foster more international participation within this collaborative group. This report reviews the results of the first in a series of these joint IEA PVPS Task 13/PVPMC workshops. The 4th PV Performance Modeling Collaborative Workshop was held in Cologne, Germany at the headquarters of TÜV Rheinland on October 22-23, 2015.

  18. Comparative analysis of two bacteriophages of Xanthomonas arboricola pv. juglandis.

    Science.gov (United States)

    Dömötör, Dóra; Frank, Tamara; Rákhely, Gábor; Doffkay, Zsolt; Schneider, György; Kovács, Tamás

    2016-09-01

    Walnut blight caused by Xanthomonas arboricola pv. juglandis (Xaj) is one of the most frequent infective diseases of walnut, resulting in serious economic losses. One potential solution to control this disease could be the application of bacteriophages. In this study, 24 phages were isolated from soil and walnut aerial tissues infected with Xaj. Two polyvalent bacteriophages, Xaj2 and Xaj24 were chosen for further characterization including their morphological, physiological and genomic analyses. Xaj2 was classified as Siphoviridae whereas Xaj24 belonged to the Podoviridae family. Both phages demonstrated lytic effect on Xaj in laboratory trials. Complete genomes of Xaj2 and Xaj24 were determined. Genomes of Xaj2 and Xaj24 consisted of 49.241 and 44.861 nucleotides encoding 80 and 53 genes, respectively. Comparative genome analyses have revealed that Xaj2 had a unique genome sequence, while Xaj24 was a phiKMV-like phage and it was most similar to the Prado phage which is virulent for Xylella fastidiosa and Xanthomonas spp. In this study, we present the first two complete Xaj phage sequences enabling an insight into the genomics of Xaj phages.

  19. Innovations in Wind and Solar PV Financing

    Energy Technology Data Exchange (ETDEWEB)

    Cory, K.; Coughlin, J.; Jenkin, T.; Pater, J.; Swezey, B.

    2008-02-01

    There is growing national interest in renewable energy development based on the economic, environmental, and security benefits that these resources provide. Historically, greater development of our domestic renewable energy resources has faced a number of hurdles, primarily related to cost, regulation, and financing. With the recent sustained increase in the costs and associated volatility of fossil fuels, the economics of renewable energy technologies have become increasingly attractive to investors, both large and small. As a result, new entrants are investing in renewable energy and new business models are emerging. This study surveys some of the current issues related to wind and solar photovoltaic (PV) energy project financing in the electric power industry, and identifies both barriers to and opportunities for increased investment.

  20. Fidelity Susceptibility as Holographic PV criticality

    CERN Document Server

    Momeni, Davood; Myrzakulov, Ratbay

    2016-01-01

    Motivated by the fact that the quantum entanglement entropy is dual to an area in AdS, quantities dual to a volume in the AdS have also been recently proposed. These include the holographic complexity and fidelity susceptibility of a quantum system. Even though both of them are dual to an volume in the bulk, there are some interesting difference between them. In this letter, we will explicitly compare them for an $ AdS _4$ solution, and clarify the main differences between them from thermodynamic point of the view. We will also obtain the correct and appropriate holographic dual of the thermodynamic volume of AdS blackhole, and demonstrate that to explain therodynamic in extended phase PV picture, from the AdS/CFT point of view,fidelity susceptibility is the preferred quantity in comparison to holographic complexity.

  1. INFLUÊNCIA DA DENSIDADE DE INÓCULO DE Fusarium solani f.sp. phaseoli NA SEVERIDADE DA PODRIDÃO RADICULAR SECA DO FEIJOEIRO EFFECT OF Fusarium solani f.sp. phaseoli INOCULUM DENSITY ON DRY ROOT ROT SEVERITY IN THE COMMON BEAN

    Directory of Open Access Journals (Sweden)

    Gesimária Ribeiro Costa

    2007-09-01

    Full Text Available

    Foram testadas quatro densidades de inóculo de Fusarium solani, em gramas por litro de solo (1,0; 2,0; 4,0 e 8,0 e um tratamento testemunha, em solo tipo Latossolo Vermelho-Escuro, cultivado e não cultivado, com o objetivo de determinar a densidade mínima de inóculo no solo necessária para a ocorrência de podridão radicular seca do feijoeiro. Como variáveis respostas foram avaliadas: número de microorganismos totais do solo, número de propágulos de F. solani, atividade microbiológica total do solo e severidade da doença em plântulas. Os resultados indicaram que a densidade de inóculo do fungo variou com o tipo de solo. Para um solo não cultivado a densidade necessária para causar a doença esteve acima de 5.127 propágulos por grama de solo, enquanto para o solo cultivado a densidade de inóculo para causar doença foi de 3.701 propágulos por grama de solo. Os índices de doença em plântulas cultivadas sob o solo cultivado foram duas vezes superiores ao índice de doença de plântulas sob o solo não cultivado. A atividade microbiológica total nos solos, determinada pela desidrogenase de fluorescina diacetato, não se correlacionou com a população dos microorganismos, indicando que a simples presença desses não implica em que estejam ativos.

    PALAVRAS-CHAVE: Solo supressivo; solo conducivo; Phaseolus vulgaris.

    Four densities of Fusarium solani inoculum (1, 2, 4 and 8 g/L of soil were tested for determining the minimum inoculum density for the occurrence of bean dry root rot, in two soil types. The response variables evaluated were the total number of microorganisms in the soil, the number of F. solani f. sp. phaseoli propagules, total soil microbial activity and seedling disease severity

  2. Managing PV Power on Mars - MER Rovers

    Science.gov (United States)

    Stella, Paul M.; Chin, Keith; Wood, Eric; Herman, Jennifer; Ewell, Richard

    2009-01-01

    The MER Rovers have recently completed over 5 years of operation! This is a remarkable demonstration of the capabilities of PV power on the Martian surface. The extended mission required the development of an efficient process to predict the power available to the rovers on a day-to-day basis. The performance of the MER solar arrays is quite unlike that of any other Space array and perhaps more akin to Terrestrial PV operation, although even severe by that comparison. The impact of unpredictable factors, such as atmospheric conditions and dust accumulation (and removal) on the panels limits the accurate prediction of array power to short time spans. Based on the above, it is clear that long term power predictions are not sufficiently accurate to allow for detailed long term planning. Instead, the power assessment is essentially a daily activity, effectively resetting the boundary points for the overall predictive power model. A typical analysis begins with the importing of the telemetry from each rover's previous day's power subsystem activities. This includes the array power generated, battery state-of-charge, rover power loads, and rover orientation, all as functions of time. The predicted performance for that day is compared to the actual performance to identify the extent of any differences. The model is then corrected for these changes. Details of JPL's MER power analysis procedure are presented, including the description of steps needed to provide the final prediction for the mission planners. A dust cleaning event of the solar array is also highlighted to illustrate the impact of Martian weather on solar array performance

  3. Valley of Death analysis for polymer PV technology; Valley of Death analyse voor polymere PV technologie

    Energy Technology Data Exchange (ETDEWEB)

    Schoots, K. [ECN Beleidsstudies, Petten (Netherlands)

    2013-12-15

    This report describes the results of a qualitative study of the barriers that actors involved in the development and commercialization of polymer solar cells, may encounter. The purpose of this socio-economic research is to identify these barriers for the (market) development of thin film polymeric PV technology and to develop strategies for them in order to overcome the constraints. The necessary data are collected from interviews with actors who are active in the development and deployment of conventional solar cells. Based on the results from this study, it is conclude that it is important for the Organic PV industry to carry out many market experiments beyond the built environment. The report provides recommendations with regard to the markets in which these experiments are most likely to succeed and which drivers should be taken into account [Dutch] Dit rapport beschrijft de resultaten van een kwalitatief onderzoek naar de barrieres die actoren, betrokken bij de ontwikkeling en marktintroductie van polymere zonnecellen, kunnen tegenkomen. Het doel van dit sociaal-economische onderzoek is deze barrieres voor de (markt)ontwikkeling van dunne film polymere PV technologie te identificeren en strategieen te ontwikkelen om ze voor te zijn of ze te overbruggen. De benodigde gegevens worden verzameld uit interviews met actoren die actief zijn in de ontwikkeling en uitrol van conventionele zonnecellen. Op basis van de resultaten uit dit onderzoek komen we tot de conclusie dat het voor de Organische PV sector belangrijk is veel marktexperimenten aan te gaan buiten de gebouwde omgeving. Het rapport geeft aanbevelingen in welke soort markten deze experimenten de meeste kans van slagen hebben en met welke drivers van marktpartijen rekening moet worden gehouden.

  4. SunShot 2030 for Photovoltaics (PV): Envisioning a Low-cost PV Future

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Frew, Bethany A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Richards, James [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sun, Yinong [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Woodhouse, Michael A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-12

    In this report we summarize the implications, impacts, and deployment potential of reaching the SunShot 2030 targets for the electricity system in the contiguous United States. We model 25 scenarios of the U.S. power sector using the Regional Energy Deployment Systems (ReEDS) and Distributed Generation (dGen) capacity expansion models. The scenarios cover a wide range of sensitivities to capture future uncertainties relating to fuel prices, retirements, renewable energy capital costs, and load growth. We give special attention to the potential for storage costs to also rapidly decline due to its large synergies with low-cost solar. The ReEDS and dGen models project utility- and distributed-scale power sector evolution, respectively, for the United States. Both models have been designed with special emphasis on capturing the unique traits of renewable energy, including variability and grid integration requirements. Across the suite of scenarios modeled, we find that reaching the SunShot 2030 target has the potential to lead to significant capacity additions of PV in the United States. By 2050, PV penetration levels are projected to reach 28-46 percent of total generation. If storage also sees significant reductions in cost, then the 2050 solar penetration levels could reach 41-64 percent. PV deployment is projected to occur in all of the lower 48 states, though the specific deployment level is scenario dependent. The growth in PV is projected to be dominated by utility-scale systems, but the actual mix between utility and distributed systems could ultimately vary depending on how policies, system costs, and rate structures evolve.

  5. Loss of local capture of the pulmonary vein myocardium after antral isolation: prevalence and clinical significance.

    Science.gov (United States)

    Squara, Fabien; Liuba, Ioan; Chik, William; Santangeli, Pasquale; Zado, Erica S; Callans, David J; Marchlinski, Francis E

    2015-03-01

    Capture of the myocardial sleeves of the pulmonary veins (PV) during PV pacing is mandatory for assessing exit block after PV isolation (PVI). However, previous studies reported that a significant proportion of PVs failed to demonstrate local capture after PVI. We designed this study to evaluate the prevalence and the clinical significance of loss of PV capture after PVI. Thirty patients (14 redo) undergoing antral PVI were included. Before and after PVI, local PV capture was assessed during circumferential pacing (10 mA/2 milliseconds) with a circular multipolar catheter (CMC), using EGM analysis from each dipole of the CMC and from the ablation catheter placed in ipsilateral PV. Pacing output was varied to optimize identification of sleeve capture. All PVs demonstrated sleeve capture before PVI, but only 81% and 40% after first time and redo PVI, respectively (P PVI). In multivariate analysis, absence of spontaneous PV depolarizations after PVI and previous PVI procedures were associated with less PV sleeve capture after PVI (40% sleeve capture, P PVI resulting in entrance block, and may be used as a specific alternate endpoint for PV electrical isolation. Additionally, loss of PV local capture may identify PVs at very low risk of acute reconnection during adenosine challenge. © 2014 Wiley Periodicals, Inc.

  6. Sub-synchronous resonance damping using high penetration PV plant

    Science.gov (United States)

    Khayyatzadeh, M.; Kazemzadeh, R.

    2017-02-01

    The growing need to the clean and renewable energy has led to the fast development of transmission voltage-level photovoltaic (PV) plants all over the world. These large scale PV plants are going to be connected to power systems and one of the important subjects that should be investigated is the impact of these plants on the power system stability. Can large scale PV plants help to damp sub-synchronous resonance (SSR) and how? In this paper, this capability of a large scale PV plant is investigated. The IEEE Second Benchmark Model aggregated with a PV plant is utilized as the case study. A Wide Area Measurement System (WAMS) based conventional damping controller is designed and added to the main control loop of PV plant in order to damp the SSR and also investigation of the destructive effect of time delay in remote feedback signal. A new optimization algorithm called teaching-learning-based-optimization (TLBO) algorithm has been used for managing the optimization problems. Fast Furrier Transformer (FFT) analysis and also transient simulations of detailed nonlinear system are considered to investigate the performance of the controller. Robustness of the proposed system has been analyzed by facing the system with disturbances leading to significant changes in generator and power system operating point, fault duration time and PV plant generated power. All the simulations are carried out in MATLAB/SIMULINK environment.

  7. Three junction holographic micro-scale PV system

    Science.gov (United States)

    Wu, Yuechen; Vorndran, Shelby; Ayala Pelaez, Silvana; Kostuk, Raymond K.

    2016-09-01

    In this work a spectrum splitting micro-scale concentrating PV system is evaluated to increase the conversion efficiency of flat panel PV systems. In this approach, the dispersed spectrum splitting concentration systems is scaled down to a small size and structured in an array. The spectrum splitting configuration allows the use of separate single bandgap PV cells that increase spectral overlap with the incident solar spectrum. This results in an overall increase in the spectral conversion efficiency of the resulting system. In addition other benefits of the micro-scale PV system are retained such reduced PV cell material requirements, more versatile interconnect configurations, and lower heat rejection requirements that can lead to a lower cost system. The system proposed in this work consists of two cascaded off-axis holograms in combination with a micro lens array, and three types of PV cells. An aspherical lens design is made to minimize the dispersion so that higher concentration ratios can be achieved for a three-junction system. An analysis methodology is also developed to determine the optical efficiency of the resulting system, the characteristics of the dispersed spectrum, and the overall system conversion efficiency for a combination of three types of PV cells.

  8. Kauai Island Utility Co-op (KIUC) PV integration study.

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, Abraham; Mousseau, Tom (Knoxville, TN)

    2011-08-01

    This report investigates the effects that increased distributed photovoltaic (PV) generation would have on the Kauai Island Utility Co-op (KIUC) system operating requirements. The study focused on determining reserve requirements needed to mitigate the impact of PV variability on system frequency, and the impact on operating costs. Scenarios of 5-MW, 10-MW, and 15-MW nameplate capacity of PV generation plants distributed across the Kauai Island were considered in this study. The analysis required synthesis of the PV solar resource data and modeling of the KIUC system inertia. Based on the results, some findings and conclusions could be drawn, including that the selection of units identified as marginal resources that are used for load following will change; PV penetration will displace energy generated by existing conventional units, thus reducing overall fuel consumption; PV penetration at any deployment level is not likely to reduce system peak load; and increasing PV penetration has little effect on load-following reserves. The study was performed by EnerNex under contract from Sandia National Laboratories with cooperation from KIUC.

  9. Impedance characterization of PV modules in outdoor conditions

    DEFF Research Database (Denmark)

    Oprea, Matei-lon; Thorsteinsson, Sune; Spataru, Sergiu;

    2016-01-01

    Impedance spectroscopy (IS) has been used for laboratory characterizations of photovoltaic (PV) technologies under well controlled conditions. This work applies IS for outdoor characterization of PV panels, in order to observe the effect of irradiance (G) and temperature (T) on the PV module’s...... impedance spectrum, and further construct an impedance model that can link environmental changes to the model’s parameters. To achieve this, an optimized setup has been developed for long-term impedance spectra monitoring synchronised with accurate irradiance and temperature data. Preliminary results show...

  10. PV Validation and Bankability Workshop: San Jose, California

    Energy Technology Data Exchange (ETDEWEB)

    Granata, J.; Howard, J.

    2011-12-01

    This report is a collaboration between Sandia National Laboratories, the National Renewable Energy Laboratory, and the Florida Solar Energy Center (FSEC). The report provides feedback from the U.S. Department of Energy's (DOE) Solar Program PV Validation and Bankability Workshop in San Jose, California on August 31, 2011. It focuses on the current state of PV in the United States, private funding to fund U.S. PV industry growth, roles and functions of the regional test center program, and ways to improve the current validation and bankability practices.

  11. PV Project Finance in the United States, 2016

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, David; Lowder, Travis; Schwabe, Paul

    2016-09-01

    This brief is a compilation of data points and market insights that reflect the state of the project finance market for solar photovoltaic (PV) assets in the United States as of the third quarter of 2016. This information can generally be used as a simplified benchmark of the costs associated with securing financing for solar PV as well as the cost of the financing itself (i.e., the cost of capital). Three sources of capital are considered -- tax equity, sponsor equity, and debt -- across three segments of the PV marketplace.

  12. Monitoring and Analysis of Two Grid Connected PV Systems

    OpenAIRE

    2013-01-01

    International audience; In this paper, two grid connected photovoltaic systems are studied and monitored for fault detection ad predictive reliability. The first PV grid, is at CNRS-PROMES laboratory in Perpignan, built in 2001 with 3 PV arrays named "Shed","Brise soleil","Mur rideau") connected to the grid thanks to many inverter of different power (3 of 4KWC and 2 of 2.5KWC). The second one is at CNRS-LAAS in Toulouse with a power of 100kWc. It is composed of a facade of 36kWc PV array and ...

  13. CPV Vs. PV from a grid-matching perspective

    Science.gov (United States)

    Strobach, E.; Bader, S.; Faiman, D.; Solomon, A. A.; Meron, G.

    2012-10-01

    In a recently-published series of papers we studied the general problem of matching large PV systems of various kinds to the electricity grid. In those studies CPV systems were simulated via an artificial ansatz in which they were treated as 2-axis flat-panel PV systems whose light sensitivity is only to the direct normal component (DNI) of solar irradiance. The present study replaces this ansatz with an experimentally validated model of a real CPV system. We compare a genuine 2-axis high-concentration CPV system with a static flat-panel PV system from the standpoint of matching both system types to the Israeli electricity grid.

  14. Power Electronic System for Multi-MW PV sites

    DEFF Research Database (Denmark)

    Paasch, Kasper

    The work presented in this thesis addresses the optimization potential of large PV power plants with respect to energy production during periods of moving clouds. Presently the number and size of utility scale Photo Voltaic (PV) power plants in the megawatt range is increasing and the market...... of energy is in the range ... for field use, is battery operated and has been applied for the characterization of a solar panel over a period of 6 months at the ESTER Outdoor PV monitoring station in Rome, Italy....

  15. Design of a Solar Tracker System for PV Power Plants

    Directory of Open Access Journals (Sweden)

    Tiberiu Tudorache

    2010-04-01

    Full Text Available This paper deals with the design and execution of a solar tracker systemdedicated to the PV conversion panels. The proposed single axis solar tracker deviceensures the optimization of the conversion of solar energy into electricity by properlyorienting the PV panel in accordance with the real position of the sun. The operation of theexperimental model of the device is based on a DC motor intelligently controlled by adedicated drive unit that moves a mini PV panel according to the signals received from twosimple but efficient light sensors. The performance and characteristics of the solar trackerare experimentally analyzed.

  16. Pigment and Virulence Deficiencies Associated with Mutations in the aroE Gene of Xanthomonas oryzae pv. oryzae

    OpenAIRE

    2001-01-01

    Xanthomonadins are yellow, membrane-bound pigments produced by members of the genus Xanthomonas. We identified an ethyl methanesulfonate-induced Xanthomonas oryzae pv. oryzae mutant (BXO65) that is deficient for xanthomonadin production and virulence on rice, as well as auxotrophic for aromatic amino acids (Pig− Vir− Aro−). Reversion analysis indicated that these multiple phenotypes are due to a single mutation. A genomic library of the wild-type strain was used to isolate a 7.0-kb clone that...

  17. A comparison of design features of 80 pv-powered products

    NARCIS (Netherlands)

    Apostolou, G.; Reinders, A.H.M.E.

    2012-01-01

    In this paper 80 commercially available PV products have been analysed. The data set comprises 46 low power PV products in the range of 0 to 17 Wp and 34 PV products with a power of 17 Wp up to 27 kWp. The goal of our study is to investigate and evaluate features of PV products that are available on

  18. Robustness analysis of the efficiency in PV inverters

    DEFF Research Database (Denmark)

    Pigazo, Alberto; Liserre, Marco; Blaabjerg, Frede;

    2013-01-01

    During last years an increasing attention has been paid to the efficiency of grid-connected PV inverters. They are manufactured from a number of discrete components and by using a certain topology and control strategy. Hence, the performance of a certain PV inverter not only depends on the selected...... topology and control strategy but also on the characteristics of the employed components. The aim of this paper is evaluate the effect of physical variations associated to the main components on the overall efficiency of PV inverters. It is concluded that a statistical evaluation of the power converter...... provides a better understanding of the PV inverter performance and, in this sense, the definition of the European Efficiency must be reviewed in order to show the quality of the manufactured product....

  19. Heritage plaza parking lots improvement project- Solar PV installation

    Energy Technology Data Exchange (ETDEWEB)

    Hooks, Todd [Agua Caliente Indian Reservation, Palm Springs, CA (United States)

    2017-03-31

    The Agua Caliente Band of Cahuilla Indians (ACBCI or the “Tribe”) installed a 79.95 kW solar photovoltaic (PV) system to offset the energy usage costs of the Tribal Education and Family Services offices located at the Tribe's Heritage Plaza office building, 90I Tahquitz Way, Palm Springs, CA, 92262 (the "Project"). The installation of the Solar PV system was part of the larger Heritage Plaza Parking Lot Improvements Project and mounted on the two southern carport shade structures. The solar PV system will offset 99% of the approximately 115,000 kWh in electricity delivered annually by Southern California Edison (SCE) to the Tribal Education and Family Services offices at Heritage Plaza, reducing their annual energy costs from approximately $22,000 annually to approximately $200. The total cost of the proposed solar PV system is $240,000.

  20. Retaining the Value of PV at High Penetration Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah; Bolen, Michael

    2016-10-13

    PV prices have dropped and are now attractive without incentives for peaking applications in some locations. Modeling suggests and, empirically, some regions demonstrate that as PV penetration increases its value decreases, predominantly due to a decrease in energy and capacity value. It is not apparent what technologies and price may be needed for PV to supply tens of percent of electricity in the most economically efficient manner. A 1-day workshop was co-sponsored by EPRI and NREL with support from ASU. A dozen presentations and discussions introduced how the interplay of various technologies impact the value of PV, identified technical challenges and gaps impeding implementation, and discussed future R&D needs and opportunities.

  1. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  2. Design Considerations for Stand-Alone Photovoltaic (PV Cell Applications

    Directory of Open Access Journals (Sweden)

    Mehmet Cebeci

    2013-06-01

    Full Text Available Solar energy is one of the most important renewable energy sources. The photovoltaic (PV cell systems are used to convert solar energy into electricity. PV systems are divided into two as fixed systems and tracking systems. Fixed systems are mounted at a certain tilt with horizontal to make full use of sunlight. The tilt angle of PV arrays in a fixed system depends on the location and time. If this tilt angle is determined well, the amount of insolation and the energy that is generated increases. When a stand-alone PV cell system is being chosen, certain design operations should be implemented. The number of modules and batteries needed for any system should be calculated by means of the amount of load, insolation level, module characteristics, etc. The design of system is finalized according to the energy demand.

  3. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented....... The main elements of the PV control structure are: - a maximum power point tracker (MPPT) algorithm using the incremental conductance method; - a synchronization method using the phase-locked-loop (PLL), based on delay; - the input power control using the dc voltage controller and power feed......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter....

  4. Angle Resolved Performance Measurements on PV Glass and Modules

    DEFF Research Database (Denmark)

    Juutilainen, Line Tollund; Thorsteinsson, Sune; Poulsen, Peter Behrensdorff

    2016-01-01

    the concept of PV balconies as cost efficient and easy way of integrating PV into buildings. The experimental work consists of the fabrication of single cell mini modules with different glass covering, and characterizing their angular response in a custom made setup, where only the direct sunlight is used......The angular response of PV-modules has significant impact on the energy production. This is especially pronounced in BIPV where installation angles often are far from optimal. Nevertheless, a gain in energy yield may be obtained by choosing a proper glass as superstrate. In this work we present...... as a light source. As a special case we estimate the annual yield for each glass in the case of PV balconies for a specific geographical location and orientation of the module....

  5. PV GRID Advisory Paper. Consultation version: key recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Bianca; Concas, Giorgia; Cossent, Rafael; Franz, Oliver; Frias, Pablo; Hermes, Roland; Lama, Riccardo; Loew, Holger; Mateo, Carlos; Rekinger, Manoel; Sonvilla, Paolo Michele; Vandenbergh, Michel

    2014-01-15

    PV GRID is a transnational collaborative effort under the umbrella of the Intelligent Energy Europe programme. The main project goal is to enhance photovoltaic (PV) hosting capacity in distribution grids while overcoming regulatory and normative barriers hampering the application of available technical solutions. The European PV GRID advisory paper aims at providing an overview of the issues and barriers that need to be addressed in order to enhance the distribution grid hosting capacity for PV and other distributed generation (DG).To this purpose, barriers are classified as either cross-cutting challenges or specific barriers, depending on whether they have an overarching, system-wide character or rather focus on one single issue such as curtailment, self-consumption or storage. Finally, a set of preliminary recommendations on how to overcome these issues is presented, allowing for the implementation of the identified technical solutions.

  6. Promotional drivers for grid-connected PV

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Polo, A.; Hass, R.; Suna, D.

    2009-03-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at promotional measures for grid-connected photovoltaic systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the core objective of this study which was to analyse the success of various governmental regulatory programs and governmental and non-governmental marketing programs for grid-connected PV systems. To meet this objective, a review of the most important past and current programs around the world was conducted. The theoretical bases of supply and demand are explained and the types of existing strategies are documented in a second Section. In Chapter 3, various programs around the world are described. Chapter 4 focuses on defining success criteria which will be used for the analysis of the programs. Finally, the major conclusions drawn complete this analysis.

  7. Evaluation of PV Module Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Wohlgemuth, John; Silverman, Timothy; Miller, David C.; McNutt, Peter; Kempe, Michael; Deceglie, Michael

    2015-06-14

    This paper describes an effort to inspect and evaluate PV modules in order to determine what failure or degradation modes are occurring in field installations. This paper will report on the results of six site visits, including the Sacramento Municipal Utility District (SMUD) Hedge Array, Tucson Electric Power (TEP) Springerville, Central Florida Utility, Florida Solar Energy Center (FSEC), the TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification. TEP Solar Test Yard, and University of Toledo installations. The effort here makes use of a recently developed field inspection data collection protocol, and the results were input into a corresponding database. The results of this work have also been used to develop a draft of the IEC standard for climate and application specific accelerated stress testing beyond module qualification.

  8. Performance and Degradation Analysis of Operating PV Systems

    Science.gov (United States)

    Da Silva Freire, Felipe

    The environmental concerns together with the decrease in technology cost lead the solar market to growth rapidly along the last decade. The photovoltaic (PV) systems are one of the solar energy alternatives and the silicon solar cells are currently the most widespread technology. Photovoltaic (PV) modules are considered the most reliable component of a photovoltaic system. The reliability and lifetime depends on the modules energy conversion performance and degradation modes. The analysis of monitoring data give insights about the PV system performance along its service time. The comparison between this data and mathematical models configure a way to predict the futures and new PV installations performance. The goal of this study is to understand the PV systems performance and degradation along its lifetime. A mathematical model was employed to predict the power output of a real, relatively new operating PV system with respect to environmental parameters temperature, irradiance and cloud coverage. The model used is based on one diode ideality factor and takes into account the parasitic series resistance. The results have been compared with the actual PV output data collected for the year 2014 and show good correlation. As the model predicts the system power output assuming the system in new conditions, the deviation in performance of the real data in comparison to the modeling results need to be further investigated for systems in service for longer time. For this propose, the study presents a condensed review of various causes of degradation in silicon PV modules and techniques to observe and investigate these degradation mechanisms. Major effects on output performance exhibit increase in observed ideality factor n2 and recombination current J02 primarily caused by decrease in minority carrier lifetime, shunts and increase in series resistance. The study further, investigates the governing degradation modes on a ten years old PV crystalline silicon module

  9. Towards a PV-θ view of the general circulation

    Science.gov (United States)

    Hoskins, Brian J.

    1991-09-01

    In recent years, there has been a resurgence of interest in using isentropic coordinates and Rossby-Ertel potential vorticity (PV) for diagnosing the behaviour of middle latitude synoptic systems. Such a PV-θ analysis may also prove important in providing insight into the global circulation of the atmosphere. Apart from the isentropic diagnostic of D. Johnson and collaborators, some quasi-geostrophic studies and recent studies of stratospheric behaviour, there has been little work in this area and our present understanding is very limited. The object of the present paper is to stimulate such studies by presenting some initial results from continuing research. A three-fold division of the atmosphere is discussed. The "Overworld" is the region encompassed by isentropic surfaces that are everywhere above the tropopause. In the "Middleworld", the region with isentropes crossing the tropopause but not striking the Earth's surface, the isentropic zonal and time mean of PV exhibits interesting regions of enhanced and diminished gradients. The isentropic transient eddy advection of PV exhibits a dipolar distribution about the tropopause, suggestive of PV mixing. The marked PV signature of the Asian summer monsoon on one particular Middleworld isentrope is shown and the mean isentropic advection of PV shows interesting features. For the "Underworld", in which isentropic surfaces intercept the surface of the Earth, a PV-θ analysis yields a novel constraint linking low-level drag and diabatic heating. This constraint links "westerlies" and "cooling", and "easterlies" and "heating" in some average sense. The result is discussed in terms of the Southern Hemisphere strong surface westerlies and the circulation associated with the Asian summer and winter monsoons.

  10. Sensitivity to copper in Xanthomonas campestris pv. viticola

    OpenAIRE

    2009-01-01

    ABSTRACT Bacterial canker, caused by Xanthomonas campestris pv. viticola, affects grapevines in the irrigated areas of the São Francisco river valley, in the states of Pernambuco and Bahia. Several practices for disease management have been adopted including copper sprays.This is the only available chemical control method and most frequently used in the areas affected by the disease. The objective of this work was to determine the sensitivity to copper of strains of X. campestris pv. vi...

  11. Microgrid-Ready Solar PV; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-07-01

    Designing new solar projects to be 'microgrid-ready' enables the U.S. DoD, other federal agencies, and the private sector to plan future microgrid initiatives to utilize solar PV as a generating resource. This fact sheet provides background information with suggested language for several up-front considerations that can be added to a solar project procurement or request for proposal (RFP) that will help ensure that PV systems are built for future microgrid connection.

  12. PV on existing roofs. Experiences of sixty households

    Energy Technology Data Exchange (ETDEWEB)

    Kaan, H.F.; Van Dijk, A.L.; Van Leeuwen, M. [ECN Renewable Energy in the Built Environment DEGO, Petten (Netherlands)

    2001-05-01

    In order to stimulate the use of PV (photovoltaic energy) in the Netherlands, the Dutch government offers a subsidy of 3.40 Euro per Watt peak installed after January 2001. It is hoped that this will facilitate the market for PV systems. The newly to be build houses form a substantial potential as PV carriers, but the existing housing stock is much larger. PV on existing houses has been promoted for several years now in the Netherlands, amongst others by utilities, PV manufacturers and the environmental organization Greenpeace. The new subsidy scheme will undoubtedly have a large impact on the PV demand for existing houses. However, it is doubtful whether the technology is mature enough to meet a large scale demand. In order to learn from experiences with small scale PV systems on roofs of existing houses, the Energy research Centre of the Netherlands (ECN) has set up a research project in which participating employees give access to the roofs of their houses to install PV systems. Fifty-nine ECN employees entered for participation in this project. This group provides a random selection of roofs, so that many different types of roof integration can be examined. Subjects included in the project investigations are: constructional aspects, yield and reliability of systems, institutional aspects such as getting building permits, aesthetics, behavioural aspects. The project was set up in 2000. In April 2001, the installation had been monitored and evaluated. Also the preparatory and initial findings and experiences of project participants have been registered through a questionnaire. The yield of the modules is registered by the participants.

  13. Solar PV Energy Conversion System and its Configurations

    Directory of Open Access Journals (Sweden)

    Ahteshamul Haque

    2016-02-01

    Full Text Available Solar PV based energy conversion system is now used in commercial and residential buildings. Advancements in Power electronics leads the researchers to enhance the use of solar application in various configurations. These configurations may be used to utilize the energy optimally. The main objective of this paper is to present an overview of the various configurations of solar PV energy conversion system

  14. Parallel experimental study of a novel super-thin thermal absorber based photovoltaic/thermal (PV/T system against conventional photovoltaic (PV system

    Directory of Open Access Journals (Sweden)

    Peng Xu

    2015-11-01

    Full Text Available Photovoltaic (PV semiconductor degrades in performance due to temperature rise. A super thin-conductive thermal absorber is therefore developed to regulate the PV working temperature by retrofitting the existing PV panel into the photovoltaic/thermal (PV/T panel. This article presented the parallel comparative investigation of the two different systems through both laboratory and field experiments. The laboratory evaluation consisted of one PV panel and one PV/T panel respectively while the overall field system involved 15 stand-alone PV panels and 15 retrofitted PV/T panels. The laboratory testing results demonstrated the PV/T panel could achieve the electrical efficiency of about 16.8% (relatively 5% improvement comparing with the stand-alone PV panel, and yield an extra amount of heat with thermal efficiency of nearly 65%. The field testing results indicated that the hybrid PV/T panel could enhance the electrical return of PV panels by nearly 3.5%, and increase the overall energy output by nearly 324.3%. Further opportunities and challenges were then discussed from aspects of different PV/T stakeholders to accelerate the development. It is expected that such technology could become a significant solution to yield more electricity, offset heating load freely and reduce carbon footprint in contemporary energy environment.

  15. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  16. PV Derived Data for Predicting Performance; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, Bill

    2015-09-14

    A method is described for providing solar irradiance data for modeling PV performance by using measured PV performance data and back-solving for the unknown direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI), which can then be used to model the performance of PV systems of any size, PV array tilt, or PV array azimuth orientation. Ideally situated for using the performance data from PV modules with micro-inverters, the PV module operating current is used to determine the global tilted irradiance (GTI), and a separation model is then used to determine the DNI and DHI from the GTI.

  17. Occurrence of Xanthomonas campestris pv. campestris (Pammel, 1895 Dowson 1939, on Brassicas in Montenegro

    Directory of Open Access Journals (Sweden)

    Dragana Radunović

    2012-01-01

    Full Text Available Brassicas form the most important group of vegetable crops in Montenegro. The cabbage(Brassica oleracea var. capitata is most commonly grown, although other brassicas,particularly kale, Brussels sprout, cauliflower and broccoli, have been increasingly producedsince recently. One of the specialties of vegetable production in Montenegro is growing ofcollard (Brassica oleracea var. acephala, which is the simplest variety of the Brassica oleraceaspecies and in the nearest relation with their wild ancestor – the sylvestris variety.Diseases are the main restrictive factors for successful production of these vegetables.Susceptibility of the cultivars and inadequate control often result in more or less damagedcrops in some plots.Causal agents of brassica diseases, especially bacterial, have not been investigated inMontenegro until 2009. Since the symptoms observed in 2009 were „V” shaped leaf edgenecrosis and black rot of vascular tissue, it was assumed that they were caused by plantpathogenic bacterium Xanthomonas campestris pv. campestris.Samples of the infected plants were collected from different localities in Montenegro.Isolation and identification of the bacterium were performed using laboratory methodsaccording to Schaad (1980, Lelliott and Stead (1987 and Arsenijević (1997. Examinationof chosen bacterial isolates was conducted using both, classical bacteriological methods(examination of their pathogenic, morphological, cultivation and biochemical and physiologicalcharacteristics, and ELISA test.The obtained results confirmed the presence of X.campestris pv. campestris (Pammel,1895 Dowson 1939, on cabbage, kale, broccoli and collard in Montenegro. This is the firstexperimental evidence that collard is the host of X. campestris pv. campestris in Montenegro.

  18. Design optimization of transformerless grid-connected PV inverters including reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost Of the Ele......This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost...... to the non-optimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  19. Continuing Developments in PV Risk Management: Strategies, Solutions, and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Lowder, T.; Mendelsohn, M.; Speer, B.; Hill, R.

    2013-02-01

    As the PV industry matures, successful risk management practices will become more imperative to ensure investor confidence, control costs, and facilitate further growth. This report discusses several key aspects of risk management during the commercial- and utility-scale project life cycle, from identification of risks, to the process of mitigating and allocating those risks among project parties, to transferring those risks through insurance. The report also explores novel techniques in PV risk management, options to offload risks onto the capital markets, and innovative insurance policies (namely warranty policies) that address risks unique to the PV sector. One of the major justifications for robust risk management in the PV industry is the cost-reduction opportunities it affords. If the PV industry can demonstrate the capability to successfully manage its risks, thereby inspiring confidence in financiers, it may be able to obtain a lower cost of capital in future transactions. A lower cost of capital translates to a lower cost of energy, which will in turn enhance PV?s competitiveness at a time when it will have to rely less on subsidies to support its market penetration.

  20. Integrating High Penetrations of PV into Southern California

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, B.; Mather, B.; Hasper-Tuttle, J.; Neal, R.; Katiraei, F.; Yazdani, A.; Aguero, J. R.; Hoff, T. E.; Norris, B. L.; Parkins, A.; Seguin, R.; Schauder, C.

    2011-01-01

    California regulators recently approved a plan proposed by Southern California Edison (SCE) to install 500 MW of distributed photovoltaic (PV) energy in its utility service territory over the next 5 years. The installations will include 250 MW of utility-owned solar and 250 MW of independently owned solar. SCE expects that the majority of these systems will be commercial-scale rooftop PV systems connected at various points in the distribution system. Each of the SCE rooftop PV systems will typically have a rating of 1-3 MW. To understand the impact of high-penetration PV on the distribution grid, the National Renewable Energy Laboratory (NREL) and SCE brought together a team of experts in resource assessment, distribution modeling, and planning to help analyze the impacts of adding high penetration of PV into the distribution system. Through modeling and simulation, laboratory testing, and field demonstrations, the team will address the issues identified in the analysis by fully examining the challenges, developing solutions, and transitioning those solutions to the field for large-scale deployment. This paper gives an update on the project and discusses technical results of integrating a large number of distributed PV systems into the grid.

  1. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  2. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  3. Review of PV Inverter Technology Cost and Performance Projections

    Energy Technology Data Exchange (ETDEWEB)

    Navigant Consulting Inc.

    2006-01-01

    The National Renewable Energy Laboratory (NREL) has a major responsibility in the implementation of the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program. Sandia National Laboratories (SNL) has a major role in supporting inverter development, characterization, standards, certifications, and verifications. The Solar Energy Technologies Program recently published a Multiyear Technical Plan, which establishes a goal of reducing the Levelized Energy Cost (LEC) for photovoltaic (PV) systems to $0.06/kWh by 2020. The Multiyear Technical Plan estimates that, in order to meet the PV system goal, PV inverter prices will need to decline to $0.25-0.30 Wp by 2020. DOE determined the need to conduct a rigorous review of the PV Program's technical and economic targets, including the target set for PV inverters. NREL requested that Navigant Consulting Inc.(NCI) conduct a review of historical and projected cost and performance improvements for PV inverters, including identification of critical barriers identified and the approaches government might use to address them.

  4. Residential Solar PV Systems in the Carolinas: Opportunities and Outcomes.

    Science.gov (United States)

    Alqahtani, Bandar Jubran; Holt, Kyra Moore; Patiño-Echeverri, Dalia; Pratson, Lincoln

    2016-02-16

    This paper presents a first-order analysis of the feasibility and technical, environmental, and economic effects of large levels of solar photovoltaic (PV) penetration within the services areas of the Duke Energy Carolinas (DEC) and Duke Energy Progress (DEP). A PV production model based on household density and a gridded hourly global horizontal irradiance data set simulates hourly PV power output from roof-top installations, while a unit commitment and real-time economic dispatch (UC-ED) model simulates hourly system operations. We find that the large generating capacity of base-load nuclear power plants (NPPs) without ramping capability in the region limits PV integration levels to 5.3% (6510 MW) of 2015 generation. Enabling ramping capability for NPPs would raise the limit of PV penetration to near 9% of electricity generated. If the planned retirement of coal-fired power plants together with new installations and upgrades of natural gas and nuclear plants materialize in 2025, and if NPPs operate flexibly, then the share of coal-fired electricity will be reduced from 37% to 22%. A 9% penetration of electricity from PV would further reduce the share of coal-fired electricity by 4-6% resulting in a system-wide CO2 emissions rate of 0.33 to 0.40 tons/MWh and associated abatement costs of 225-415 (2015$ per ton).

  5. Control Strategies for the DAB Based PV Interface System.

    Science.gov (United States)

    El-Helw, Hadi M; Al-Hasheem, Mohamed; Marei, Mostafa I

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system.

  6. Control Strategies for the DAB Based PV Interface System

    Science.gov (United States)

    El-Helw, Hadi M.; Al-Hasheem, Mohamed; Marei, Mostafa I.

    2016-01-01

    This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system. PMID:27560138

  7. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  8. PVMirrors: Hybrid PV/CSP collectors that enable lower LCOEs

    Science.gov (United States)

    Fisher, Kate; Yu, Zhengshan Jason; Striling, Rob; Holman, Zachary

    2017-06-01

    The primary challenge with concentrating solar power (CSP) is that the conversion efficiency is low—and the cost high—compared to that of photovoltaics (PV), and the primary challenge with PV is that the energy generated cannot be stored cost effectively. We introduce a technology that hybridizes CSP and PV, resulting in power plants with high energy conversion efficiency and affordable storage. This is accomplished by replacing silvered troughs (or heliostat facets) with "PVMirrors" that and direct photons of each wavelength to the converter (PV or thermal) that may best use them. A PVMirror looks like a curved PV module that includes a spectrum-splitting dichroic mirror film; this film, which is the heart of the technology, transmits near-infrared light to the underlying silicon PV cells while reflecting both longer and shorter wavelengths to a thermal absorber tube. This paper investigates the optical performance of dichroic mirror film, the specularity of PVMirrors, and the anticipated levelized cost of energy (LCOE) from a PVMirror power plant. PVMirrors are found to decrease LCOE by more than 15% relative to CSP while retaining full dispatchability.

  9. Biosynthesis of compatible solutes in rhizobial strains isolated from Phaseolus vulgaris nodules in Tunisian fields

    Directory of Open Access Journals (Sweden)

    Nieto Joaquín J

    2010-07-01

    Full Text Available Abstract Background Associated with appropriate crop and soil management, inoculation of legumes with microbial biofertilizers can improve food legume yield and soil fertility and reduce pollution by inorganic fertilizers. Rhizospheric bacteria are subjected to osmotic stress imposed by drought and/or NaCl, two abiotic constraints frequently found in semi-arid lands. Osmostress response in bacteria involves the accumulation of small organic compounds called compatible solutes. Whereas most studies on rhizobial osmoadaptation have focussed on the model species Sinorhizobium meliloti, little is known on the osmoadaptive mechanisms used by native rhizobia, which are good sources of inoculants. In this work, we investigated the synthesis and accumulations of compatible solutes by four rhizobial strains isolated from root nodules of Phaseolus vulgaris in Tunisia, as well as by the reference strain Rhizobium tropici CIAT 899T. Results The most NaCl-tolerant strain was A. tumefaciens 10c2, followed (in decreasing order by R. tropici CIAT 899, R. leguminosarum bv. phaseoli 31c3, R. etli 12a3 and R. gallicum bv. phaseoli 8a3. 13C- and 1H-NMR analyses showed that all Rhizobium strains synthesized trehalose whereas A. tumefaciens 10c2 synthesized mannosucrose. Glutamate synthesis was also observed in R. tropici CIAT 899, R. leguminosarum bv. phaseoli 31c3 and A. tumefaciens 10c2. When added as a carbon source, mannitol was also accumulated by all strains. Accumulation of trehalose in R. tropici CIAT 899 and of mannosucrose in A. tumefaciens 10c2 was osmoregulated, suggesting their involvement in osmotolerance. The phylogenetic analysis of the otsA gene, encoding the trehalose-6-phosphate synthase, suggested the existence of lateral transfer events. In vivo 13C labeling experiments together with genomic analysis led us to propose the uptake and conversion pathways of different carbon sources into trehalose. Collaterally, the β-1,2-cyclic glucan from R

  10. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    OpenAIRE

    Tamer Khatib; Azah Mohamed; K. Sopian

    2012-01-01

    This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV) systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN), optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based mo...

  11. Investigation of the Effect Temperature on Photovoltaic (PV) Panel Output Performance

    OpenAIRE

    Amelia Razak; Y.M. Irwan; W.Z. Leow; M Irwanto; I. Safwati; M. Zhafarina

    2016-01-01

    The main limit of PV systems is the low conversion efficiency of PV panels, which is strongly influenced by their operating temperature. Lack of accuracy in consideration through PV panel temperature increases the financial risk of system installation. This present study investigates the effects of operating temperature on monocrystalline PV panel at Perlis, Malaysia. A selected model of PV panel firstly was simulated using PVSYST software in order to evaluate its output performance. Meanwhil...

  12. Proposal of Xanthomonas translucens pv. pistaciae pv. nov., pathogenic to pistachio (Pistacia vera).

    Science.gov (United States)

    Giblot-Ducray, Danièle; Marefat, Alireza; Gillings, Michael R; Parkinson, Neil M; Bowman, John P; Ophel-Keller, Kathy; Taylor, Cathy; Facelli, Evelina; Scott, Eileen S

    2009-12-01

    Strains of Xanthomonas translucens have caused dieback in the Australian pistachio industry for the last 15 years. Such pathogenicity to a dicotyledonous woody host contrasts with that of other pathovars of X. translucens, which are characterized by their pathogenicity to monocotyledonous plant families. Further investigations, using DNA-DNA hybridization, gyrB gene sequencing and integron screening, were conducted to confirm the taxonomic status of the X. translucens pathogenic to pistachio. DNA-DNA hybridization provided a clear classification, at the species level, of the pistachio pathogen as a X. translucens. In the gyrB-based phylogeny, strains of the pistachio pathogen clustered among the X. translucens pathovars as two distinct lineages. Integron screening revealed that the cassette arrays of strains of the pistachio pathogen were different from those of other Xanthomonas species, and again distinguished two groups. Together with previously reported pathogenicity data, these results confirm that the pistachio pathogen is a new pathovar of X. translucens and allow hypotheses about its origin. The proposed name is Xanthomonas translucens pv. pistaciae pv. nov.

  13. Multiplex PCR for detection of lukS/F-PV and mecA genes in Staphylococcus aureus isolates%多重PCR检测临床分离金黄色葡萄球菌lukS/F-PV和mecA基因

    Institute of Scientific and Technical Information of China (English)

    闫中强; 沈定霞; 罗燕萍; 曹敬荣

    2008-01-01

    目的 建立一种新的多重PCR方法,检测临床分离金葡菌的杀白细胞素毒力基因(lukS/F-PV)和甲氧西林耐药基因(mecA).方法 收集我院2006年1-12月从临床多种标本中分离鉴定的不重复金葡菌,应用多重PCR技术,优化反应条件,同时扩增葡萄球菌属特异性基因16S rRNA、金葡菌种特异性基因nuc、lukS/F-PV基因和mecA基因,扩增产物经凝胶成像系统分析.结果 217株金葡菌经多重PCR检测,31株是16S rRNA + nuc + lukS/F-PV + mecA基因型,3株是16S rRNA + nuc + lukS/F-PV基因型,135株是16S rRNA + nuc + mecA基因型,40株是16S rRNA + nuc 基因型,其中5株仅扩增出16S rRNA 基因,3株仅扩增出nuc基因.lukS/F-PV基因和mecA基因测序显示与GenBank中的已有序列具有高度同源性,其阳性率分别为15.7%(34/217)和76.5%(166/217);34株lukS/F-PV基因阳性的分离株中,31株为MRSA,占91.2%(31/34).结论 本方法适用于快速检测和鉴定产杀白细胞素MRSA,lukS/F-PV基因阳性的菌株以MRSA为主,应加强监控.

  14. Diversity of sporadic symbionts and nonsymbiotic endophytic bacteria isolated from nodules of woody, shrub, and food legumes in Ethiopia.

    Science.gov (United States)

    Aserse, Aregu Amsalu; Räsänen, Leena A; Aseffa, Fassil; Hailemariam, Asfaw; Lindström, Kristina

    2013-12-01

    Fifty-five bacterial isolates were obtained from surface-sterilized nodules of woody and shrub legumes growing in Ethiopia: Crotalaria spp., Indigofera spp., and Erythrina brucei, and the food legumes soybean and common bean. Based on partial 16S rRNA gene sequence analysis, the majority of the isolates were identified as Gram-negative bacteria belonging to the genera Achromobacter, Agrobacterium, Burkholderia, Cronobacter, Enterobacter, Mesorhizobium, Novosphingobium, Pantoea, Pseudomonas, Rahnella, Rhizobium, Serratia, and Variovorax. Seven isolates were Gram-positive bacteria belonging to the genera Bacillus, Paenibacillus, Planomicrobium, and Rhodococcus. Amplified fragment length polymorphism (AFLP) fingerprinting showed that each strain was genetically distinct. According to phylogenetic analysis of recA, glnII, rpoB, and 16S rRNA gene sequences, Rhizobium, Mesorhizobium, and Agrobacterium were further classified into six different genospecies: Agrobacterium spp., Agrobacterium radiobacter, Rhizobium sp., Rhizobium phaseoli, Mesorhizobium sp., and putative new Rhizobium species. The strains from R. phaseoli, Rhizobium sp. IAR30, and Mesorhizobium sp. ERR6 induced nodules on their host plants. The other strains did not form nodules on their original host. Nine endophytic bacterial strains representing seven genera, Agrobacterium, Burkholderia, Paenibacillus, Pantoea, Pseudomonas, Rhizobium, and Serratia, were found to colonize nodules of Crotalaria incana and common bean on co-inoculation with symbiotic rhizobia. Four endophytic Rhizobium and two Agrobacterium strains had identical nifH gene sequences with symbiotic Rhizobium strains, suggesting horizontal gene transfer. Most symbiotic and nonsymbiotic endophytic bacteria showed plant growth-promoting properties in vitro, which indicate their potential role in the promotion of plant growth when colonizing plant roots and the rhizosphere.

  15. Recurrence of pulmonary vein conduction and atrial fibrillation after pulmonary vein isolation for atrial fibrillation: a randomized trial of the ostial versus the extraostial ablation strategy

    DEFF Research Database (Denmark)

    Nilsson, Brian; Chen, Xu; Pehrson, Steen;

    2006-01-01

    BACKGROUND: Both segmental ostial and circumferential extraostial pulmonary vein (PV) isolation have been proven effective in the treatment of atrial fibrillation (AF). However, the recurrence of AF and PV conduction after the 2 ablation strategies has never been compared in a randomized study....... METHODS: A total of 100 consecutive patients (age 56 +/- 10; 71 men) with symptomatic AF (paroxysmal, 51; persistent, 49) were randomized to segmental ostial (n = 54) or circumferential extraostial (n = 46) PV isolation. A circular catheter positioned at the ostium of each target PV guided the ostial PV...... who underwent ostial PV isolation (P strategies was mainly seen in patients known with persistent AF (52% and 15%, respectively; P = .02) as opposed to patients with paroxysmal AF (65% and 46%, respectively; P = .26). CONCLUSIONS: Overall...

  16. Performance of a 34 kWp grid-connected PV system in Indonesia - A comparison of tropical and European PV systems

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    We analysed a monitored grid-connected PV system of 34 kWp in Indonesia to investigate the performance of PV systems in tropical climates. The PV system has been installed in Jayapura, the capital of the Province of Papua, Indonesia, by the beginning of 2012. Due to the aged gensets and frequent lac

  17. Plug and Play PV Systems for American Homes

    Energy Technology Data Exchange (ETDEWEB)

    Hoepfner, Christian [Fraunhofer USA, Inc., Boston, MA (United States)

    2016-12-22

    The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

  18. PV-BUK: Operating and maintenance costs of photovoltaic installations; PV-BUK - Betriebs- und Unterhaltskosten von PV-Anlagen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Stettler, S.; Toggweiler, P. [Enecolo AG, Moenchaltorf (Switzerland); Ruoss, D.; Schudel, P. [Envision, Lucerne (Switzerland); Kottmann, A.; Steinle, F. [BE Netz AG, Lucerne (Switzerland)

    2008-03-15

    This final report elaborated for the Swiss Federal Office of Energy (SFOE) takes a look at the results of a project carried out to determine the costs for facility management, to estimate future cost development and to propose activities for the further reduction of the operation and maintenance costs of photovoltaic systems. Information on the cost situation was collected by literature study, as well as in interviews and surveys with photovoltaic (PV) experts and the owners of PV installations. The discussion of the results at a workshop with about 20 Swiss PV experts is noted. The results are presented and discussed. These show that operating costs per kWh decrease with the size of the PV system. Figures are quoted. The major part of the costs are quoted as being those for spare parts, especially for the inverter. The authors are of the opinion that, in future, costs for facility management will further decrease, as they are partly linked to capital and insurance costs. Potential for optimisation is said to exist in several areas of facility management such as, for example, in system monitoring and fast reaction in the case of malfunctions.

  19. Lifetime Evaluation of PV Inverters considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    The PV inverter lifetime is affected by the installed sites related to different solar irradiance and ambient temperature profiles. In fact, the installation site also affects the PV panel degradation rate, and thus the long-term power production. Prior-art lifetime analysis in PV inverters has...... not yet investigated the impact of panel degradation. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and installation sites. Evaluations have been carried out on PV systems installed in Denmark and Arizona. The results reveal that the PV panel degradation rate...... has a considerable impact on the PV inverter lifetime, especially in the hot climate (e.g., Arizona), where the panel degrades at a faster rate. In that case, the PV inverter lifetime estimation can be deviated by 54%, if the impact of PV panel degradation is not taken into account....

  20. Policies and opportunities for grid parity of PV in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Lako, P.; Beurskens, L.W.M. [ECN Policy Studies, Petten (Netherlands)

    2012-01-15

    In 2010, ECN Policy Studies has provided information on the development of solar PV in the Netherlands to GlobalData, India. Based on this information request, the present note on policies and opportunities for grid parity of PV has been drafted. Recently, subsidies for solar PV in the Netherlands have shown a pattern of a roller-coaster that is typical for PV financing in a number of EU countries. Stop-and-go policies for solar PV may have multiple causes. It may be difficult to determine the right feed-in tariffs for PV; or governments may be reluctant to provide sufficient funding for a relatively expensive renewable electricity source like PV. This note sheds light on the current state of affairs and policies for PV in the Netherlands, and on several private initiatives aimed at reaching grid parity for PV which is installed by households.

  1. Methods for the Optimal Design of Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    and the efficient processing of this power by the DC/AC inverter. In this paper two new methods are presented for the optimal design of a PV inverter power section, output filter and MPPT control strategy. The influences of the electric grid regulations and standards as well as the PV array operational......The DC/AC inverters are used in grid-connected PV energy production systems as the power processing interface between the PV energy source and the electric grid. The energy injected into the electric grid by the PV installation depends on the amount of power extracted from the PV power source...... characteristics on the design of grid-connected PV inverters have been considered. The proposed methods have been applied for the optimal design of PV inverters installed at various sites in Europe. The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy...

  2. Performance of a PV module augmented by a plane reflector

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, G. E; Hussein, H. M. S; Mohamad, M. A [Dokki, Giza (Egypt)

    2000-07-01

    This paper presents a comparative experimental study on the performance of a PV module augmented by a south facing titled plane reflector and another identical one without reflector. The tilt angles of the two PV modules and reflector overhang are selected to be according to a previous theoretical study by the authors. The reflector tilt angle has been changed once a month so that the reflected beams from the plane reflector cover the total surface area of the PV module all days of every month during the high solar radiation period (i.e. three hours before and after solar noon). The study has been carried out on the two PV modules for a complete year under the actual atmospheric conditions of Cairo, Egypt. The measuring system used in the study comprises a data acquisition system, a computer, an electronic load and weather station. The experimental results indicate that the plane reflector enhances the yearly output energy of the PV module y about 22%. [Spanish] Este articulo presenta un estudio comparativo experimental sobre el rendimiento de un modulo de PV aumentado por un reflector plano inclinado mirando hacia el sur y otro identico sin reflector. Los angulos de inclinacion de los dos modulos y el reflector sobresaliente se seleccionan para que esten de acuerdo con un estudio teorico previo hecho por los autores. El angulo de inclinacion del reflector se cambio una vez al mes de manera que los rayos reflejados por el reflector plano cubrieran el area total de la superficie del modulo de PV todos los dias de cada mes durante el periodo de radiacion alto (o sea tres horas antes y despues del medio dia solar). El estudio ha sido llevado a cabo en dos modulos de PV durante un ano completo bajo condiciones atmosfericas reales de El Cairo, Egipto. El sistema de medicion usado en el estudio comprende un sistema de adquisicion de datos, una computadora, una memoria electronica y una estacion climatologica. Los resultados experimentales indican que el reflector plano

  3. PV Reconfiguration Systems: a Technical and Economic Study

    Directory of Open Access Journals (Sweden)

    Caruso M.

    2017-03-01

    Full Text Available Dynamical electrical array reconfiguration strategies for grid-connected PV systems have been proposed as solution to improve energy production due to the mismatch effect of PV plants during partial shading conditions. Strategies are based on the use of dynamic connections between PV panels given by the employment of switches that allow for each panel the series, parallel or exclusion connections, physically changing the electrical connections between the related PV modules, consequentially modifying the layout of the plant. Usually the cost of the dynamic matrix is not taken into account. This novel work evaluates the economic advantages obtained by the use of reconfiguration strategies in PV systems, by taking into consideration the price of energy due to incentives in different European and non-European countries and correlates it with the employment of two types of reconfigurators, with different internal structures. For each of the incentives proposed by the different Countries, the main strength and weakness points of the possible investment are highlighted and critically analyzed. From this analysis, it can be stated that the adoption of reconfiguration systems, in certain cases, can be a very convenient solution.

  4. Solar cell junction temperature measurement of PV module

    KAUST Repository

    Huang, B.J.

    2011-02-01

    The present study develops a simple non-destructive method to measure the solar cell junction temperature of PV module. The PV module was put in the environmental chamber with precise temperature control to keep the solar PV module as well as the cell junction in thermal equilibrium with the chamber. The open-circuit voltage of PV module Voc is then measured using a short pulse of solar irradiation provided by a solar simulator. Repeating the measurements at different environment temperature (40-80°C) and solar irradiation S (200-1000W/m2), the correlation between the open-circuit voltage Voc, the junction temperature Tj, and solar irradiation S is derived.The fundamental correlation of the PV module is utilized for on-site monitoring of solar cell junction temperature using the measured Voc and S at a short time instant with open circuit. The junction temperature Tj is then determined using the measured S and Voc through the fundamental correlation. The outdoor test results show that the junction temperature measured using the present method, Tjo, is more accurate. The maximum error using the average surface temperature Tave as the junction temperature is 4.8 °C underestimation; while the maximum error using the present method is 1.3 °C underestimation. © 2010 Elsevier Ltd.

  5. Thermal performances of vertical hybrid PV/T air collector

    Science.gov (United States)

    Tabet, I.; Touafek, K.; Bellel, N.; Khelifa, A.

    2016-11-01

    In this work, numerical analyses and the experimental validation of the thermal behavior of a vertical photovoltaic thermal air collector are investigated. The thermal model is developed using the energy balance equations of the PV/T air collector. Experimental tests are conducted to validate our mathematical model. The tests are performed in the southern Algerian region (Ghardaïa) under clear sky conditions. The prototype of the PV/T air collector is vertically erected and south oriented. The absorber upper plate temperature, glass cover temperature, air temperature in the inlet and outlet of the collector, ambient temperature, wind speed, and solar radiation are measured. The efficiency of the collector increases with increase in mass flow of air, but the increase in mass flow of air reduces the temperature of the system. The increase in efficiency of the PV/T air collector is due to the increase in the number of fins added. In the experiments, the air temperature difference between the inlet and the outlet of the PV/T air collector reaches 10 ° C on November 21, 2014, the interval time is between 10:00 and 14:00, and the temperature of the upper plate reaches 45 ° C at noon. The mathematical model describing the dynamic behavior of the typical PV/T air collector is evaluated by calculating the root mean square error and mean absolute percentage error. A good agreement between the experiment and the simulation results is obtained.

  6. Design of direct solar PV driven air conditioner

    KAUST Repository

    Huang, Bin-Juine

    2015-12-05

    © 2015 Elsevier Ltd. Solar air conditioning system directly driven by stand-alone solar PV is studied. The air conditioning system will suffer from loss of power if the solar PV power generation is not high enough. It requires a proper system design to match the power consumption of air conditioning system with a proper PV size. Six solar air conditioners with different sizes of PV panel and air conditioners were built and tested outdoors to experimentally investigate the running probabilities of air conditioning at various solar irradiations. It is shown that the instantaneous operation probability (OPB) and the runtime fraction (RF) of the air conditioner are mainly affected by the design parameter rpL (ratio of maximum PV power to load power). The measured OPB is found to be greater than 0.98 at instantaneous solar irradiation IT > 600 W m-2 if rpL > 1.71 RF approaches 1.0 (the air conditioner is run in 100% with solar power) at daily-total solar radiation higher than 13 MJ m-2 day-1, if rpL > 3.

  7. ESTIMATION OF PV MODULE SURFACE TEMPERATURE USING ARTIFICIAL NEURAL NETWORKS

    Directory of Open Access Journals (Sweden)

    Can Coskun

    2016-12-01

    Full Text Available This study aimed to use the artificial neural network (ANN method to estimate the surface temperature of a photovoltaic (PV panel. Using the experimentally obtained PV data, the accuracy of the ANN model was evaluated. To train the artificial neural network (ANN, outer temperature solar radiation and wind speed values were inputs and surface temperature was an output. The ANN was used to estimate PV panel surface temperature. Using the Levenberg-Marquardt (LM algorithm the feed forward artificial neural network was trained. Two back propagation type ANN algorithms were used and their performance was compared with the estimate from the LM algorithm. To train the artificial neural network, experimental data were used for two thirds with the remaining third used for testing. Additionally scaled conjugate gradient (SCG back propagation and resilient back propagation (RB type ANN algorithms were used for comparison with the LM algorithm. The performances of these three types of artificial neural network were compared and mean error rates of between 0.005962 and 0.012177% were obtained. The best estimate was produced by the LM algorithm. Estimation of PV surface temperature with artificial neural networks provides better results than conventional correlation methods. This study showed that artificial neural networks may be effectively used to estimate PV surface temperature.

  8. Solar Plus: A Holistic Approach to Distributed Solar PV

    Energy Technology Data Exchange (ETDEWEB)

    OShaughnessy, Eric J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ardani, Kristen B. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cutler, Dylan S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-06-08

    Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

  9. Solar Plus: A Holistic Approach to Distributed Solar PV

    Energy Technology Data Exchange (ETDEWEB)

    O' Shaughnessy, Eric; Ardani, Kristen; Cutler, Dylan; Margolis, Robert

    2017-05-25

    Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

  10. Durability Quality Research of Concrete Containing Solar PV Cells

    Directory of Open Access Journals (Sweden)

    Chao Sao-Jeng

    2015-01-01

    Full Text Available In this article we demonstrated the study results of durability quality of concrete containing waste solar PV cells. The study used alkali activator to improve the activity of alkali-activated materials in solar PV cells so as to replace Portland cement as binder in concrete. By using sodium hydroxide as an alkali-activator, a high-pH environment is generated to excite the binding characteristics of alkali-activated materials in solar PV cells, and thus develops better durability of the mixes. The conclusions were made on effect of this cement replacement. As a result, we identified the durability for those of 16 concrete specimens predefined and made to consider various possible control factors. The conclusions also depicted that all experiments but the drying shrinkage may be helpful with the suitable use of control factors as far as concerning the recycled solar PV cells for mixing in concrete. In other words, the durability quality of concrete may be partially unacceptable of containing solar PV cells.

  11. Mutations of ferric uptake regulator (fur) impair iron homeostasis, growth, oxidative stress survival, and virulence of Xanthomonas campestris pv. campestris.

    Science.gov (United States)

    Jittawuttipoka, Thichakorn; Sallabhan, Ratiboot; Vattanaviboon, Paiboon; Fuangthong, Mayuree; Mongkolsuk, Skorn

    2010-05-01

    Iron is essential in numerous cellular functions. Intracellular iron homeostasis must be maintained for cell survival and protection against iron's toxic effects. Here, we characterize the roles of Xanthomonas campestris pv. campestris (Xcc) fur, which encodes an iron sensor and a transcriptional regulator that acts in iron homeostasis, oxidative stress, and virulence. Herein, we isolated spontaneous Xcc fur mutants that had high intracellular iron concentrations due to constitutively high siderophore levels and increased expression of iron transport genes. These mutants also had reduced aerobic plating efficiency and resistance to peroxide killing. Moreover, one fur mutant was attenuated on a host plant, thus indicating that fur has important roles in the virulence of X. campestris pv. campestris.

  12. Genome sequence and rapid evolution of the rice pathogen Xanthomonas oryzae pv. oryzae PXO99A

    Directory of Open Access Journals (Sweden)

    Szurek Boris

    2008-05-01

    Full Text Available Abstract Background Xanthomonas oryzae pv. oryzae causes bacterial blight of rice (Oryza sativa L., a major disease that constrains production of this staple crop in many parts of the world. We report here on the complete genome sequence of strain PXO99A and its comparison to two previously sequenced strains, KACC10331 and MAFF311018, which are highly similar to one another. Results The PXO99A genome is a single circular chromosome of 5,240,075 bp, considerably longer than the genomes of the other strains (4,941,439 bp and 4,940,217 bp, respectively, and it contains 5083 protein-coding genes, including 87 not found in KACC10331 or MAFF311018. PXO99A contains a greater number of virulence-associated transcription activator-like effector genes and has at least ten major chromosomal rearrangements relative to KACC10331 and MAFF311018. PXO99A contains numerous copies of diverse insertion sequence elements, members of which are associated with 7 out of 10 of the major rearrangements. A rapidly-evolving CRISPR (clustered regularly interspersed short palindromic repeats region contains evidence of dozens of phage infections unique to the PXO99A lineage. PXO99A also contains a unique, near-perfect tandem repeat of 212 kilobases close to the replication terminus. Conclusion Our results provide striking evidence of genome plasticity and rapid evolution within Xanthomonas oryzae pv. oryzae. The comparisons point to sources of genomic variation and candidates for strain-specific adaptations of this pathogen that help to explain the extraordinary diversity of Xanthomonas oryzae pv. oryzae genotypes and races that have been isolated from around the world.

  13. Objective quantification of perturbations produced with a piecewise PV inversion technique

    Directory of Open Access Journals (Sweden)

    L. Fita

    2007-11-01

    Full Text Available PV inversion techniques have been widely used in numerical studies of severe weather cases. These techniques can be applied as a way to study the sensitivity of the responsible meteorological system to changes in the initial conditions of the simulations. Dynamical effects of a collection of atmospheric features involved in the evolution of the system can be isolated. However, aspects, such as the definition of the atmospheric features or the amount of change in the initial conditions, are largely case-dependent and/or subjectively defined. An objective way to calculate the modification of the initial fields is proposed to alleviate this problem. The perturbations are quantified as the mean absolute variations of the total energy between the original and modified fields, and an unique energy variation value is fixed for all the perturbations derived from different PV anomalies. Thus, PV features of different dimensions and characteristics introduce the same net modification of the initial conditions from an energetic point of view. The devised quantification method is applied to study the high impact weather case of 9–11 November 2001 in the Western Mediterranean basin, when a deep and strong cyclone was formed. On the Balearic Islands 4 people died, and sustained winds of 30 ms−1 and precipitation higher than 200 mm/24 h were recorded. Moreover, 700 people died in Algiers during the first phase of the event. The sensitivities to perturbations in the initial conditions of a deep upper level trough, the anticyclonic system related to the North Atlantic high and the surface thermal anomaly related to the baroclinicity of the environment are determined. Results reveal a high influence of the upper level trough and the surface thermal anomaly and a minor role of the North Atlantic high during the genesis of the cyclone.

  14. Lifetime Evaluation of Grid-Connected PV Inverters Considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    Lifetime of PV inverters is affected by the installation sites related to different solar irradiance and ambient temperature profiles (also referred to as mission profiles). In fact, the installation site also affects the degradation rate of the PV panels, and thus long-term energy production...... and reliability. Prior-art lifetime analysis in PV inverters has not yet investigated the impact of PV panel degradations. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and mission profiles. Evaluations have been carried out on PV systems installed in Denmark...

  15. Interline Photovoltaic (I-PV) power system - A novel concept of power flow control and management

    OpenAIRE

    2011-01-01

    This paper presents a new system configuration for a large-scale Photovoltaic (PV) power system with multi-line transmission/distribution networks. A PV power plant is reconfigured in a way that two adjacent power system networks/ feeders can be interconnected. The inverter modules in a PV power plant are configured such that the system is represented as a back to back inverter connected multi-line system, called as Interline-PV (I-PV) system. The proposed I-PV system then can be controlled a...

  16. Photovoltaic Module Simulink Model for a Stand-alone PV System

    Science.gov (United States)

    Qi, Chen; Ming, Zhu

    Photovoltaic(PV) Module is indispensable of a stand-alone PV system. In this paper, a one-diode equivalent circuit-based versatile simulation model in the form of masked block PV module is proposed. By the model, it is allowed to estimate behavior of PV module with respect changes on irradiance intensity, ambient temperature and parameters of the PV module. In addition, the model is capable of function of Maximum Power Point Tracking (MPPT) which can be used in the dynamic simulation of stand-alone PV systems.

  17. Comparative assessment of PV plant performance models considering climate effects

    DEFF Research Database (Denmark)

    Tina, Giuseppe; Ventura, Cristina; Sera, Dezso

    2017-01-01

    The paper investigates the effect of climate conditions on the accuracy of PV system performance models (physical and interpolation methods) which are used within a monitoring system as a reference for the power produced by a PV system to detect inefficient or faulty operating conditions....... The methodological approach is based on comparative tests of the analyzed models applied to two PV plants installed respectively in north of Denmark (Aalborg) and in the south of Italy (Agrigento). The different ambient, operating and installation conditions allow to understand how these factors impact the precision...... and effectiveness of such approaches, among these factors it is worth mentioning the different percentage of diffuse component of the yearly solar radiation on the global one. The experimental results show the effectiveness of the proposed approach. In order to have the possibility to analyze and compare...

  18. Chapter 10.3: Reliability and Durability of PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2017-01-07

    Each year the world invests tens of billions of dollars or euros in PV systems with the expectation that these systems will last approximately 25 years. Although the disciplines of reliability, quality, and service life prediction have been well established for numerous products, a full understanding of these is currently challenging for PV modules because the desired service lifetimes are decades, preventing direct verification of lifetime predictions. A number of excellent reviews can be found in the literature summarizing the types of failures that are commonly observed for PV modules. This chapter discusses key failure/degradation mechanisms selected to highlight how the kinetics of failure rates can and cannot be confidently predicted. For EVA-encapsulated modules, corrosion is observed to follow delamination, which then allows water droplets to directly contact the metallization. Extended test protocols such as Qualification Plus were created to address the known problems while standards groups update standard tests through the consensus process.

  19. DC-PLC Modem design for PV module monitoring

    Directory of Open Access Journals (Sweden)

    Seong-Duc Ma

    2016-01-01

    Full Text Available Nowadays, power line communication (PLC is a very efficient technique in cost aspect because it is communication system using power line without extra communication cables. In case of DC-PLC, it send a communication signal of the high frequency band to the monitoring system through the DC power line and is widely used for DC grid or the distributed generation system using DC source. Especially, the management system which evaluates the performance and efficiency of PV module by measuring PV power through monitoring system based on the DC-PLC has been increased. In this paper, apply the DC-PLC method for low cost PV module monitoring system and constitutes a measuring device and communication modem on a MCU. For the communication performance, we use the digital filter and apply the multi-carrier communication. The proposed DC-PLC Modem is verified through simulation and experiment.

  20. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Weng, Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefit the industry at-large.

  1. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    Energy Technology Data Exchange (ETDEWEB)

    Enbar, Nadav [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Weng, Dean [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefi t the industry at-large.

  2. Z - Source Multi Level Inverter Based PV Generation System

    Directory of Open Access Journals (Sweden)

    T. Lakhmi kanth

    2014-09-01

    Full Text Available In this paper a novel technique of Z-Source multilevel Inverter based PV Generation system is implemented and simulated using MATLAB-Simulink simulation software. The Photovoltaic cells are healthier option for converting solar energy into electricity. Due to high capital cost and low efficiency PV cells have not yet been a fully smart choice for electricity users. To enhance the performance of the system, Z-Source multi level inverter can be used in place of conventional Voltage Source Inverter (VSI in Solar Power Generation System. The PV cell model is developed using circuit mathematical equations. The Z-Source multilevel inverter is modeled to realize boosted DC to AC conversion (inversion with low THD. Outcome shows that the energy conversion efficiency of ZSMLI is a lot improved as compared to conventional voltage Source Inverter (VSI. By doing FFT analysis we can know the total THD.

  3. PV Systems Installed in Marine Vessels: Technologies and Specifications

    Directory of Open Access Journals (Sweden)

    Ioannis Kobougias

    2013-01-01

    Full Text Available Considerations are held about the specificationin whichthe PV plants have to fulfill so that they can be installed on marine vessels. Initially, a brief description of the typical electrical grid of ships is presented, distinguishing the main parts, reporting the typical electrical magnitudes, and choosing the most preferable installation areas. The technical specifications,in whichthe PV plants have to be compatible with, are fully described. They are determined by the special marine environmental conditions, taking into consideration parameters like wind, humidity, shading, corrosion, and limited installation area. The work is carried out with the presentation of the most popular trends in the field of solar cell types and PV system technologies and their ability to keep up with the aforementioned specifications.

  4. Sizing aspects of a small scale grid connected PV system

    Energy Technology Data Exchange (ETDEWEB)

    Bartha, S.; Teodoreanu, D.I.; Teodoreanu, M.; Negreanu, C. [I.C.P.E.-New Energy Sources Laboratory (NESL), Bucharest (Romania); Farkas, I.; Seres, I. [Szent Istvan University, Goedoelloe (Hungary). Department of Physics and Process Control

    2008-07-01

    Photovoltaics can be used in grid connected mode in two ways: as array installed at the end use site, such as on rooftops, or as utility-scale generating stations. The present paper describes a small-scale grid connected Photovoltaic system. The paper starts with the structure and characterization of the system. The principal technical parameter data are also presented. The used monitoring parameters indicate the principal meteorological data, air temperature and solar radiation data for the location sited at Agigea, at the Black Sea and the produced energy by the PV modules. The present application is made by 1 subsystem with 1200 Wp power and with the panel inclination possibility, using different type of PV modules. The paper presents a simulation model for this system realized with commercial software packages and with a one self made Matlab model that evaluates the energy balance of the PV system. All the simulation and measurements data are presented. (orig.)

  5. Comparative analysis of old, recycled and new PV modules

    Directory of Open Access Journals (Sweden)

    Haroon Ashfaq

    2017-01-01

    Full Text Available This paper presents comparative analysis of old, recycled and new PV modules. It is possible to recycle even very old products by modern standard processes in a value-conserving manner. About 90% of the materials recovered from solar panels can be recycled into useful products. Carbon emission and energy cost are low in manufacturing recycled SPV. Modules can be manufactured with recycled materials and reinstalled in systems as a full quality product with today’s technology good for another 25–30 years. Analysis of all the models of PV module is done with the help of MATLAB. This helps in comparison and proves the effectiveness of the recycled PV module based systems.

  6. Lessons Learned from the Photovoltaic Manufacturing Technology/PV Manufacturing R&D and Thin Film PV Partnership Projects

    Energy Technology Data Exchange (ETDEWEB)

    Margolis, R.; Mitchell, R.; Zweibel, K.

    2006-09-01

    As the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program initiates new cost-shared solar energy R&D under the Solar America Initiative (SAI), it is useful to analyze the experience gained from cost-shared R&D projects that have been funded through the program to date. This report summarizes lessons learned from two DOE-sponsored photovoltaic (PV) projects: the Photovoltaic Manufacturing Technology/PV Manufacturing R&D (PVMaT/PVMR&D) project and the Thin-Film PV Partnership project. During the past 10-15 years, these two projects have invested roughly $330 million of government resources in cost-shared R&D and leveraged another $190 million in private-sector PV R&D investments. Following a description of key findings and brief descriptions of the PVMaT/PVMR&D and Thin-Film PV Partnership projects, this report presents lessons learned from the projects.

  7. Design, Fabrication and Certification of Advanced Modular PV Power Systems

    Science.gov (United States)

    Minyard, Glen E.; Lambarski, Timothy J.

    1997-02-01

    The Design, Fabrication and Certification of Advanced Modular PV Power Systems contract is a Photovoltaic Manufacturing Technology (PVMaT) cost-shared contract under Phase 4A1 for Product Driven Systems and Component Technologies. Phase 4A1 has the goals to improve the cost-effectiveness and manufacturing efficiency of PV end-products, optimize manufacturing and packaging methods, and generally improve balance-of-system performance, integration and manufacturing. This contract has the specific goal to reduce the installed PV system life cycle costs to the customer with the ultimate goal of increasing PV system marketability and customer acceptance. The specific objectives of the project are to develop certified, standardized, modular, pre-engineered products lines of our main stand-alone systems, the Modular Autonomous PV Power Supply (MAPPS) and PV-Generator Hybrid System (Photogenset). To date, we have designed a 200 W MAPPS and a 1 kW Photogenset and are in the process of having the MAPPS certified by Underwriters Laboratories (UL Listed) and approved for hazardous locations by Factory Mutual (FM). We have also developed a manufacturing plan for product line expansion for the MAPPS. The Photogenset will be fabricated in February 1997 and will also be UL Listed. Functionality testing will be performed at NREL and Sandia with the intentions of providing verification of performance and reliability and of developing test-based performance specifications. In addition to an expansion on the goals, objectives and status of the project, specific accomplishments and benefits are also presented in this paper.

  8. Time series power flow analysis for distribution connected PV generation.

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Robert Joseph; Quiroz, Jimmy Edward; Ellis, Abraham; Reno, Matthew J.; Smith, Jeff; Dugan, Roger

    2013-01-01

    Distributed photovoltaic (PV) projects must go through an interconnection study process before connecting to the distribution grid. These studies are intended to identify the likely impacts and mitigation alternatives. In the majority of the cases, system impacts can be ruled out or mitigation can be identified without an involved study, through a screening process or a simple supplemental review study. For some proposed projects, expensive and time-consuming interconnection studies are required. The challenges to performing the studies are twofold. First, every study scenario is potentially unique, as the studies are often highly specific to the amount of PV generation capacity that varies greatly from feeder to feeder and is often unevenly distributed along the same feeder. This can cause location-specific impacts and mitigations. The second challenge is the inherent variability in PV power output which can interact with feeder operation in complex ways, by affecting the operation of voltage regulation and protection devices. The typical simulation tools and methods in use today for distribution system planning are often not adequate to accurately assess these potential impacts. This report demonstrates how quasi-static time series (QSTS) simulation and high time-resolution data can be used to assess the potential impacts in a more comprehensive manner. The QSTS simulations are applied to a set of sample feeders with high PV deployment to illustrate the usefulness of the approach. The report describes methods that can help determine how PV affects distribution system operations. The simulation results are focused on enhancing the understanding of the underlying technical issues. The examples also highlight the steps needed to perform QSTS simulation and describe the data needed to drive the simulations. The goal of this report is to make the methodology of time series power flow analysis readily accessible to utilities and others responsible for evaluating

  9. Epicardial isolation of pulmonary veins with ethanol in open chest dogs

    Institute of Scientific and Technical Information of China (English)

    YIN Xian-dong; DONG Jian-zeng; MA Chang-sheng; NING Man; SANG Cai-hua; MIAO Cheng-long; LIANG Cui; TANG Ri-bo; LONG De-yong; YU Rong-hui; LIU Xing-peng

    2011-01-01

    Background Radiofrequency (RF) ablation has become a widely accepted treatment for atrial fibrillation (AF). This study aimed to identify the efficacy and safety of pulmonary vein (PV) ablation with ethanol and to explore an alternative energy source for catheter ablation of AF.Methods Twelve open-chest mongrel dogs were randomized into ethanol ablation group and control group. Both the injections and electrophysiological mapping procedures were performed epicardialy. In ethanol ablation group (n=6),injections were performed to circumferentially ablate the root of each PV (0.2 ml each site, 3 mm apart) with 95% ethanol using an 1 ml injector. In control group (n=-6), saline was injected other than ethanol. PV isolation was confirmed with a circular catheter immediately after the procedure and at follow up of 30 days. PV isolation was defined as the absence of PV potentials at each electrode of the circular catheter positioned at the PV side of the lesions, as well as complete conduction block into left atrium (LA) during PV pacing.Results PV electrical isolation with complete bidirectional conduction block was achieved with ethanol immediately and at 30 days in 95% of PVs, while saline injection caused only transient conduction changes between LA and PVs. In ethanol group, histologic analysis showed transmural lesions at 30 days. And there was no evidence of PV stenosis or thrombus formation. Mean LA diameter was not significantly different between baseline and 30 days.Conclusion Ethanol is a safe energy source to effectively isolate PV in canine model and may be promising in endocardial ablation procedure of AF patients in the future.

  10. PV domestic field trial. Third annual technical report

    Energy Technology Data Exchange (ETDEWEB)

    Crick, F.; Davies, N.; Munzinger, M.; Pearsall, N.; Martin, C.

    2004-07-01

    This report summaries the results of a field trials investigating the design, construction and operation of photovoltaic (PV) systems installed during 2003 to provide information for utilities, building developers and those involved in PV installations and operations. Topics examined include the appearance of the systems, their architectural integration, the different fixing methods, the cost effectiveness of the systems, problems encountered, and monitoring activities. Key issues discussed include communication and co-ordination between interested bodies, siting and location, and good practice. Details are given of monitoring inspection visits, and performance analysis.

  11. Spatio-temporal analysis of regional PV generation

    DEFF Research Database (Denmark)

    Nuño Martinez, Edgar; Cutululis, Nicolaos Antonio

    2016-01-01

    Photovoltaic (PV) power is growing in importance worldwide and hence needs to be represented in operation and planning of power system. As opposed to traditional generation technologies, it is characterized by exhibiting both a high variability and a significant spatial dependence. This paper...... presents a fundamental analysis of regional solar generation time series, aiming to potentially facilitate large-scale solar integration. It will focus on characterizing the underlying dependence structure at the system level as well as describing both statistical and temporal properties of regional PV...

  12. Design and Implementation of A PV Powered Tri-Cycle

    Directory of Open Access Journals (Sweden)

    Soumya Das

    2016-04-01

    Full Text Available Solar PV technology is one of the first among the various renewable energy technologies that have been adopted and accepted universally in order to meet the basic needs of generation of electricity. The objective of this paper is to propose a tri-cycle that utilises the application of stand-alone photovoltaic (PV system. A preliminary design and construction of a solar tri-cycle has been performed by evaluating and estimating the required panel size, battery capacity and motor power. Calculation in this paper exhibit that the solar power alone will be sufficient to operate a tri-cycle from one place to another.

  13. High Efficient Bidirectional Battery Converter for residential PV Systems

    DEFF Research Database (Denmark)

    Pham, Cam; Kerekes, Tamas; Teodorescu, Remus

    2012-01-01

    Photovoltaic (PV) installation is suited for the residential environment and the generation pattern follows the distribution of residential power consumption in daylight hours. In the cases of unbalance between generation and demand, the Smart PV with its battery storage can absorb or inject...... the power to balance it. High efficient bidirectional converter for the battery storage is required due high system cost and because the power is processed twice. A 1.5kW prototype is designed and built with CoolMOS and SiC diodes, >;95% efficiency has been obtained with 200 kHz hard switching....

  14. Whitey Swagelok SCHe Ball Valves Provide Isolation between SCHe Purge Lines C and D and the Process Vent

    Energy Technology Data Exchange (ETDEWEB)

    MISKA, C.R.

    2000-09-15

    These valves are 1/4 inch ball valves fabricated of 316 stainless steel. Packing is TFE (standard). They provide an isolation function betwen SCHe Purge Line C, (PV-V-*079), and Purge Line D, (PV-V-*080), and the Process Vent.

  15. Task 9. PV deployment in developing countries. Institutional framework and financial instruments for PV deployment in developing countries

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-09-15

    This report for the International Energy Agency (IEA) made by Task 9 of the Photovoltaic Power Systems (PVPS) programme takes a look at the institutional framework and financial instruments necessary for PV deployment in developing countries. This guide describes the institutional and financial aspects that need to be addressed to ensure that a long term sustainable (and profitable) PV market is established in developing countries. The guide details main fundamental functions that need to be performed such as the agents needed to perform the functions and their differing roles within the framework, the relationships between these agents and the financial instruments available. It is stated that the majority of the aspects recommended in this guide can be adopted to two main PV deployment models: direct sales and rural electrification and development programmes. It is noted that both approaches will have to be tailored and adapted to local conditions.

  16. DC Injection Elimination Using Modified Resonant Controller in Unipolar Switched Transformerless H-Bridge PV Inverter

    Directory of Open Access Journals (Sweden)

    Anjali Varghese C

    2013-08-01

    Full Text Available The necessity of efficient topologies for photovoltaic (PV inverters is a concern presently. With the advent of transformerless inverters, the size, volume and cost of PV inverters can be decreased. Efficiency can be increased nearly by 2% by avoiding the galvanic connection. With no galvanic isolation comes the problem of dc injection which pauses serious problems to core saturation of distribution transformers and cable corrosion and has to be limited as per IEEE, IEC standards. This paper presents a proportional resonant controller and is used along with a modelled series capacitance to limit DC injection. This avoids the use of a real capacitor in the output of the inverter used conventionally toprevent dc injection and hence overcomes the drawbacks of series voltage drops and reverse polarity effects. The topology of inverter chosen is the H-Bridge and switching scheme used is unipolar PWMconsidering the advantages of the same . A comparison of the dc injection values with and without the controller is presented for unipolar pulse width modulated (PWM inverters.

  17. Comparison of three different methods of perturbing the potential vorticity field in mesoscale forecasts of Mediterranean heavy precipitation events: PV-gradient, PV-adjoint and PV-satellite

    Science.gov (United States)

    Vich, M.; Romero, R.; Richard, E.; Arbogast, P.; Maynard, K.

    2010-09-01

    Heavy precipitation events occur regularly in the western Mediterranean region. These events often have a high impact on the society due to economic and personal losses. The improvement of the mesoscale numerical forecasts of these events can be used to prevent or minimize their impact on the society. In previous studies, two ensemble prediction systems (EPSs) based on perturbing the model initial and boundary conditions were developed and tested for a collection of high-impact MEDEX cyclonic episodes. These EPSs perturb the initial and boundary potential vorticity (PV) field through a PV inversion algorithm. This technique ensures modifications of all the meteorological fields without compromising the mass-wind balance. One EPS introduces the perturbations along the zones of the three-dimensional PV structure presenting the local most intense values and gradients of the field (a semi-objective choice, PV-gradient), while the other perturbs the PV field over the MM5 adjoint model calculated sensitivity zones (an objective method, PV-adjoint). The PV perturbations are set from a PV error climatology (PVEC) that characterizes typical PV errors in the ECMWF forecasts, both in intensity and displacement. This intensity and displacement perturbation of the PV field is chosen randomly, while its location is given by the perturbation zones defined in each ensemble generation method. Encouraged by the good results obtained by these two EPSs that perturb the PV field, a new approach based on a manual perturbation of the PV field has been tested and compared with the previous results. This technique uses the satellite water vapor (WV) observations to guide the correction of initial PV structures. The correction of the PV field intents to improve the match between the PV distribution and the WV image, taking advantage of the relation between dark and bright features of WV images and PV anomalies, under some assumptions. Afterwards, the PV inversion algorithm is applied to run

  18. Characteristics of Bacterial Strains from Pseudomonas Genera Isolated from Diseased Plum Trees

    Directory of Open Access Journals (Sweden)

    Veljko Gavrilović

    2008-01-01

    Full Text Available Characteristics of Pseudomonas syringae strains isolated from diseased plum trees are presented is this paper. Based on pathogenic, biochemical and physiological characteristics, isolated starins were divided into two groups: First group of strains, isolated from diseased plum branches with symptoms of suden decay, was simillar to Pseudomonas syringae pv. syringae; second group of strains, isolated from necrotic flower buds on plum trees, exhibited characteristics simillar to Pseudomonas syringae pv. morsprunorum. In addition, phytopathogenic fungi belonging to genera Phomopsis, Botryosphaeria and Leucostoma, were also isolated from diseased plum trees. Further study of these pathogens and their role in the epidemiology of suden plum trees decay is in progress.

  19. Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated such that......This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated...... that compared to the nonoptimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE....

  20. Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barbose, Galen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wiser, Ryan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Darghouth, Naim [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goodrich, Alan [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-11-30

    The installed capacity of global and U.S. photovoltaic (PV) systems has soared in recent years, driven by declining PV prices and government incentives. The U.S. Department of Energy’s (DOE) SunShot Initiative aims to make PV cost competitive without incentives by reducing the cost of PV-generated electricity by about 75% between 2010 and 2020. This summary report—based on research at Lawrence Berkeley National Laboratory (LBNL) and the National Renewable Energy Laboratory (NREL)—examines progress in PV price reductions to help DOE and other PV stakeholders manage the transition to a market-driven PV industry, and to provide clarity surrounding the wide variety of potentially conflicting data available about PV system prices.

  1. Power Output Improvement of PV Module for Agricultural Use by Using Inexpensive Sunlight Concentrator

    Institute of Scientific and Technical Information of China (English)

    NISHIMURA Ryo

    2010-01-01

    PV modules are used as stand alone power sources for agricultural equipments such as lifting pumps in farms,where the power infrastructure is not yet improved.In order to expand the agricultural use of PV module,the cost of PV generation should be reduced.In this paper,the power output performance of a commercial PV module was improved by using a sunlight concentrator that could be assembled inexpensively and a simple sun-tracking method.

  2. Equipment and procedures for ON-SITE testing of PV plants and BIPV

    OpenAIRE

    2014-01-01

    Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on...

  3. Performance enhancement of PV cells through micro-channel cooling

    Directory of Open Access Journals (Sweden)

    Muzaffar Ali

    2015-11-01

    Full Text Available Efficiency of a PV cell is strongly dependent on its surface temperature. The current study is focused to achieve maximum efficiency of PV cells even in scorching temperatures in hot climates like Pakistan where the cell surface temperatures can even rise up to around 80 ℃. The study includes both the CFD and real time experimental investigations of a solar panel using micro channel cooling. Initially, CFD analysis is performed by developing a 3D model of a Mono-Crystalline cell with micro-channels to analyze cell surface temperature distribution at different irradiance and water flow rates. Afterwards, an experimental setup is developed for performance investigations under the real conditions of an open climate of a Pakistan's city, Taxila. Two 35W panels are manufactured for the experiments; one is based on the standard manufacturing procedure while other cell is developed with 4mm thick aluminum sheet having micro-channels of cross-section of 1mm by 1mm. The whole setup also includes different sensors for the measurement of solar irradiance, cell power, surface temperature and water flow rates. The experimental results show that PV cell surface temperature drop of around 15 ℃ is achieved with power increment of around 14% at maximum applied water flow rate of 3 LPM. Additionally, a good agreement is also found between CFD and experimental results. Therefore, that study clearly shows that a significant performance improvement of PV cells can be achieved through the proposed cell cooling technique.

  4. 5bv.3.21 PV led engine

    DEFF Research Database (Denmark)

    Thorsteinsson, Sune; Poulsen, Peter Behrensdorff; Dam-Hansen, Carsten

    PV-powered lighting systems, light to light systems (L2L), offer outdoor lighting where it is elsewhere cumbersome to enable lighting. Application of these systems at high latitudes, where the difference in day length between summer and winter is large and the solar energy is less requires smart ...

  5. Grid Integration of Large PV Power Systems Using HVDC Link

    Directory of Open Access Journals (Sweden)

    Gamal Sowilam

    2016-09-01

    Full Text Available This paper explores the interconnection of large scale Photo-Voltaic (PV systems to the grid though a High Voltage Direct Current (HVDC link. HVDC link is recently utilized for transmission lines longer than 50 km. It is usually utilized to interconnect two asynchronous grids with the same or different frequencies while avoiding stability disturbances greatly. A suitable Maximum Power Point Tracking (MPPT techniques is employed to control the performance of the integrated PV system. The system of the HVDC link has two 12-pulse converter using thyristor-bridges. The delay and the extinction angles at the rectifier and the inverter units control the flow and the quantity of the transmitted power from the PV system into the grid. Fixed capacitors and filters are used to provide the AC side with the required reactive power and reduce the harmonic contents. For evaluation purposes, different simulation investigations are carried out with a detailed modeling using the MATLAB. These tests corroborate the efficacy of HVDC link for integrating large PV systems to electrical grids.

  6. Silicon Oxynitride Thin Film Barriers for PV Packaging (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    del Cueto, J. A.; Glick, S. H.; Terwilliger, K. M.; Jorgensen, G. J.; Pankow, J. W.; Keyes, B. M.; Gedvilas, L. M.; Pern, F. J.

    2006-10-03

    Dielectric, adhesion-promoting, moisture barriers comprised of silicon oxynitride thin film materials (SiOxNy with various material stoichiometric compositions x,y) were applied to: 1) bare and pre-coated soda-lime silicate glass (coated with transparent conductive oxide SnO2:F and/or aluminum), and polymer substrates (polyethylene terephthalate, PET, or polyethylene napthalate, PEN); plus 2) pre- deposited photovoltaic (PV) cells and mini-modules consisting of amorphous silicon (a-Si) and copper indium gallium diselenide (CIGS) thin-film PV technologies. We used plasma enhanced chemical vapor deposition (PECVD) process with dilute silane, nitrogen, and nitrous oxide/oxygen gas mixtures in a low-power (< or = 10 milliW per cm2) RF discharge at ~ 0.2 Torr pressure, and low substrate temperatures < or = 100(degrees)C, over deposition areas ~ 1000 cm2. Barrier properties of the resulting PV cells and coated-glass packaging structures were studied with subsequent stressing in damp-heat exposure at 85(degrees)C/85% RH. Preliminary results on PV cells and coated glass indicate the palpable benefits of the barriers in mitigating moisture intrusion and degradation of the underlying structures using SiOxNy coatings with thicknesses in the range of 100-200 nm.

  7. Comparison of Predictive Models for PV Module Performance (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Marion, B.

    2008-05-01

    This paper examines three models used to estimate the maximum power (P{sub m}) of PV modules when the irradiance and PV cell temperature are known: (1) the power temperature coefficient model, (2) the PVFORM model, and (3) the bilinear interpolation model. A variation of the power temperature coefficient model is also presented that improved model accuracy. For modeling values of P{sub m}, an 'effective' plane-of-array (POA) irradiance (E{sub e}) and the PV cell temperature (T) are used as model inputs. Using E{sub e} essentially removes the effects of variations in solar spectrum and reflectance losses, and permits the influence of irradiance and temperature on model performance for P{sub m} to be more easily studied. Eq. 1 is used to determine E{sub e} from T and the PV module's measured short-circuit current (I{sub sc}). Zero subscripts denote performance at Standard Reporting Conditions (SRC).

  8. Recent advances in PV systems technology development in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Imamura, M.; Grottke, M.; Weiss, I. [WIP Renewable Energies Division, Munich (Germany)

    1995-11-01

    The objectives of the photovoltaics (PV) systems technology development were to study several aspects of plant design, monitoring, control, operation, and management of different types of photovoltaic plants. Unsolved problems were to be identified and analysed, and guidelines to improve the monitoring system were to be developed. Principal studies are summarized.

  9. Design of fibre reinforced PV concepts for building integrated applications

    NARCIS (Netherlands)

    Reinders, Angelina H.M.E.; de Wit, H.; de Boer, Andries; Ossenbrink Sinke, W.; Helm, P.

    2009-01-01

    Fibre reinforced polymers present an interesting encapsulation medium for PV-modules. Glass fibres can provide increased strength and stiffness to thin polymer layers overcoming the brittleness and limited deformability of glass-panes. Glass fibre reinforced polymers allows for transparency over a

  10. Luminescence imaging strategies for drone-based PV array inspection

    DEFF Research Database (Denmark)

    Benatto, Gisele Alves dos Reis; Riedel, Nicholas; Thorsteinsson, Sune

    2017-01-01

    he goal of this work is to perform outdoor defect detection imaging that will be used in a fast, accurate and automatic drone-based survey system for PV power plants. The imaging development focuses on techniques that do not require electrical contact, permitting automatic drone inspections to be...

  11. Selecting Solar. Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    This analysis leverages available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  12. PV industry growth and module reliability in Thailand

    Science.gov (United States)

    Chenvidhya, Dhirayut; Seapan, Manit; Sangpongsanont, Yaowanee; Chenvidhya, Tanokkorn; Limsakul, Chamnan; Songprakorp, Roongrojana

    2015-09-01

    The PV applications in Thailand are now installed more than 1.2 GWp cumulatively. It is due to the National Renewable Energy Program and its targets. In the latest Alternative Energy Development Plan (AEDP), the PV electricity production target has increased from 2 GWp to 3 GWp. With this rapid growth, customers and manufacturers seek for module standard testing. So far over one thousands of PV modules per annum have been tested since 2012. The normal tests include type approval test according to TIS standard, acceptance test and testing for local standard development. For type test, the most module failure was found during damp heat test. For annual evaluation test, the power degradation and delamination of power was found between 0 to 6 percent from its nameplate after deployment of 0 to 5 years in the field. For thin-film module, the degradation and delamination was found in range of 0 to 13 percent (about 5 percent on average) from its nameplate for the modules in operation with less than 5 years. However, for the PV modules at the reference site on campus operated for 12 years, the power degradation was ranging from 10 to 15 percent. Therefore, a long term performance assessment needs to be considered to ensure the system reliability.

  13. Development of white LED based PV lighting systems

    Energy Technology Data Exchange (ETDEWEB)

    Sastry, O.S.; Pant, P.C.; Prasad, G.; Kumar, Rajesh; Bandyopadhyay, Bibek [Solar Energy Centre, Ministry of New and Renewable Energy, Block 14, CGO Complex, Lodhi Road, New Delhi 110003 (India); Kamala Devi, V. [Agency for Non-Conventional Energy and Rural Technology, P.B. No. 1094, Pattom, P.O. Kasavadasapuram, Trivandrum, Kerala 695 004 (India)

    2010-09-15

    A high performance white light emitting diode (WLED) based PV lighting system has been developed under a joint project of SEC and ANERT. The system has been analyzed using the test set-ups developed as a part of advanced lighting laboratory (ALL). The results show that the performance is one of the best among the systems developed in the capacity range. (author)

  14. Design of fibre reinforced PV concepts for building integrated applications

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Wit, de H.; Boer, de A.

    2009-01-01

    Fibre reinforced polymers present an interesting encapsulation medium for PV-modules. Glass fibres can provide increased strength and stiffness to thin polymer layers overcoming the brittleness and limited deformability of glass-panes. Glass fibre reinforced polymers allows for transparency over a b

  15. Best practices for mitigating soiling risk on PV power plants

    KAUST Repository

    AlDowsari, A.

    2015-09-24

    Solar power generates proven, predictable and economical energy and new innovations have made solar PV power plants easy to deploy, integrate and maintain. Areas with large solar energy potential are among the dustiest in the world. At first glance, solar would be a natural fit in many of these environments but humidity, airborne dust, and wind of these regions often bring high soiling rates that can accumulate to reduce performance by up to 10% per month on average, where soiling can be a major loss factor that affects the energy yield for PV plants especially in humid and dusty climates. Therefore, to achieve the desired performance ratio and obtain stable generation, mitigation solutions are proposed to overcome dust issues that affect the performance of PV plants. This makes PV module cleaning a key component for long-term plant performance and sustainable profitability. In this paper, a review of the mechanisms and mitigation solutions to overcome soiling on solar installations using real-world testing and verification is investigated with emphasis on dry type cleaning methods. © 2014 IEEE.

  16. ECO-TOURISM SUSTAINABILITY THROUGH PV TECHNOLOGY: A COMPREHENSIVE REVIEW

    Directory of Open Access Journals (Sweden)

    ARAVIND C. V

    2013-12-01

    Full Text Available Through the Economic Transformation program the Malaysian Government aims to consider tourism as one of the major contributors to the country’s economy and as an industry that imbibe on the principles of environmental responsibility and sustainable development. The growing challenges in the prevention of expansion in agriculture, forestry and aquaculture, and over-exploitation of the natural resources, have made ecotourism extremely popular as a solution for developing tourism sites. Ecotourism attracts many people who wish not only to explore natural wonders but also to protect them for future generations. Most of the ecotourism sites are presumably situated far from the conventional energy resources and thus transporting electricity to those areas are discussed as inefficient and unsustainable. However, solar Photo-voltaic (PV system is clean and alternative energy to suffice the energy demands of eco-tourist sites. This paper puts statements of the energy demand in global and its impact on the traditional fossil fuels and proposes PV as an alternative renewable technology pertaining to the eco-tourism application. The paper especially focuses on solar PV systems which not only could supply the energy demand of tourist sites but can also maintain the image of the ecotourism. A case of a model lodge is used for the study, through the energy demand analysis. A comprehensive review on the PV architecture is presented that derive interest in the implementation of such structure for the case presented.

  17. Dye solar cells ( and PV's) in South Africa

    CSIR Research Space (South Africa)

    Le Roux, Lukas J

    2006-02-01

    Full Text Available of the research on PV's in South Africa such as CuInSe(sub2) but with the emphasis on the DSC. The author shall report on the available facilities in South Africa well as the DSC research at the CSIR, which will include specific topics and problems. More...

  18. Rooftop PV system. PV:BONUS Phase 3B, final technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    Under the PV:BONUS Program, ECD and United Solar developed, demonstrated and commercialized two new lightweight, flexible BIPV modules specifically designed as replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and can be used to address the even larger roofing-replacement market. An important design feature of these modules, which minimizes the installation and balance-of-system costs, is their ability to be installed by conventional roofing contractors without special training. The modules are fabricated from high-efficiency, triple-junction spectrum-splitting a-Si alloy solar cells developed by ECD and United Solar. These cells are produced on thin, flexible stainless steel substrates and encapsulated with polymer materials. The Phase 3 program began in August 1995. The principal tasks and goals of this program, which have all been successfully completed by ECD and United Solar, are described in the body and appendices of this report.

  19. Insights into xanthomonas axonopodis pv. Citri biofilm through proteomics

    KAUST Repository

    Zimaro, Tamara

    2013-08-07

    Background: Xanthomonas axonopodis pv. Citri (X. a. pv. Citri) causes citrus canker that can result in defoliation and premature fruit drop with significant production losses worldwide. Biofilm formation is an important process in bacterial pathogens and several lines of evidence suggest that in X. a. pv. Citri this process is a requirement to achieve maximal virulence since it has a major role in host interactions. In this study, proteomics was used to gain further insights into the functions of biofilms. Results: In order to identify differentially expressed proteins, a comparative proteomic study using 2D difference gel electrophoresis was carried out on X. a. pv. Citri mature biofilm and planktonic cells. The biofilm proteome showed major variations in the composition of outer membrane proteins and receptor or transport proteins. Among them, several porins and TonB-dependent receptor were differentially regulated in the biofilm compared to the planktonic cells, indicating that these proteins may serve in maintaining specific membrane-associated functions including signaling and cellular homeostasis. In biofilms, UDP-glucose dehydrogenase with a major role in exopolysaccharide production and the non-fimbrial adhesin YapH involved in adherence were over-expressed, while a polynucleotide phosphorylase that was demonstrated to negatively control biofilm formation in E. coli was down-regulated. In addition, several proteins involved in protein synthesis, folding and stabilization were up-regulated in biofilms. Interestingly, some proteins related to energy production, such as ATP-synthase were down-regulated in biofilms. Moreover, a number of enzymes of the tricarboxylic acid cycle were differentially expressed. In addition, X. a. pv. Citri biofilms also showed down-regulation of several antioxidant enzymes. The respective gene expression patterns of several identified proteins in both X. a. pv. Citri mature biofilm and planktonic cells were evaluated by

  20. Real Time Photovoltaic Array Simulator for Testing Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sera, Dezso; Valentini, Massimo; Raducu, Alin

    2008-01-01

    In this paper a real time flexible PV array simulator is presented. It is a system that can simulate different PV panel arrays in specific environmental conditions. To evaluate performance of the Maximum Power Point Tracking (MPPT) of grid-connected Photovoltaic (PV) inverters only measurements...

  1. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants: Report Summary

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul L. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Eichman, Joshua D. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-28

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  2. Developing High PV Penetration Cases for Frequency Response Study of U.S. Western Interconnection

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jin; Zhang, Yingchen; Veda, Santosh; Elgindy, Tarek; Liu, Yilu

    2017-05-11

    Recent large penetrations of solar photovoltaic (PV) generation and the inertial characteristics of inverter-based generation technologies have caught the attention of those in the electric power industry in the United States. This paper presents a systematic approach to developing test cases of high penetrations of PV for the Western Interconnection. First, to examine the accuracy of the base case model, the Western Electricity Coordinating Council (WECC) model is validated by using measurement data from synchronized phasor measurement units. Based on the 2022 Light Spring case, we developed four high PV penetration cases for the WECC system that are of interest to the industry: 5% PV+15 % wind, 25% PV+15% wind, 45% PV+15% wind, 65% PV+15% wind). Additionally, a method to project PV is proposed that is based on collected, realistic PV distribution information, including the current and future PV power plant locations and penetrations in the WECC system. Both the utility-scale PV plant and residential rooftop PV are included in this study.

  3. Analytical expression for electrical efficiency of PV/T hybrid air collector

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Swapnil; Sandhu, G.S.; Tiwari, G.N. [Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110 016 (India)

    2009-05-15

    The overall electrical efficiency of the photovoltaic (PV) module can be increased by reducing the temperature of the PV module by withdrawing the thermal energy associated with the PV module. In this communication an attempt has been made to develop analytical expression for electrical efficiency of PV module with and without flow as a function of climatic and design parameters. The four different configurations of PV modules are considered for the present study which are defined as; case A (Glass to glass PV module with duct), case B (Glass to glass PV module without duct), case C (Glass to tedlar PV module with duct), case D (Glass to tedlar PV module without duct). Further, experiments were carried out for all configurations under composite climate of New Delhi. It is found that the glass to glass PV modules with duct gives higher electrical efficiency as well as the higher outlet air temperature amongst the all four cases. The annual effect on electrical efficiency of glass to glass type PV module with and without duct is also evaluated. The annual average efficiency of glass to glass type PV module with and without duct is 10.41% and 9.75%, respectively. (author)

  4. Methodology for the optimal design of tansformerless grid-connected PV interters

    DEFF Research Database (Denmark)

    Koutroulis, E.; Blaabjerg, Frede

    2012-01-01

    inverter, such that the PV inverter levelised cost of the generated electricity is minimised. The proposed method constitutes a systematic design process, which is capable to explore the impact of the PV inverter configuration on the trade-off between the PV inverter manufacturing cost and the power losses...

  5. A Novel Technique to Obtain the Health of a PV Panel

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar; Imran, Raja Muhammad; Shoro, Ghulam Mustafa

    2014-01-01

    Power efficiency delivered from a PV panel individually or as larger system for example a PV Solar Form is very much dependent upon many factors for example irradiance, temperature, shadowing and the health of individual PV panels/cells. The first two factors are typically beyond the control of d...

  6. Developing High PV Penetration Cases for Frequency Response Study of U.S. Western Interconnection: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Jin; Zhang, Yingchen; Veda, Santosh; Elgindy, Tarek; Liu, Yilu

    2017-04-11

    Recent large penetrations of solar photovoltaic (PV) generation and the inertial characteristics of inverter-based generation technologies have caught the attention of those in the electric power industry in the United States. This paper presents a systematic approach to developing test cases of high penetrations of PV for the Western Interconnection. First, to examine the accuracy of the base case model, the Western Electricity Coordinating Council (WECC) model is validated by using measurement data from synchronized phasor measurement units. Based on the 2022 Light Spring case, we developed four high PV penetration cases for the WECC system that are of interest to the industry: 5% PV+15 % wind, 25% PV+15% wind, 45% PV+15% wind, 65% PV+15% wind). Additionally, a method to project PV is proposed that is based on collected, realistic PV distribution information, including the current and future PV power plant locations and penetrations in the WECC system. Both the utility-scale PV plant and residential rooftop PV are included in this study.

  7. PV-θ view of the zonal mean state of the atmosphere

    NARCIS (Netherlands)

    van Delden, A.J.; Hinssen, Y.B.L.

    2012-01-01

    The relation between zonal mean potential vorticity (PV) in potential temperature (u) coordinates and the zonal mean zonal wind in January and in July is studied. PV-anomalies are defined with respect to a reference state that is at rest with respect to the rotating earth. Two important PV-anomalies

  8. Quantifying system-wide financial costs and benefits of PV in South Africa

    CSIR Research Space (South Africa)

    Bischof-Niemz, T

    2015-09-01

    Full Text Available 000 MW from PV) was commissioned and fed energy into the grid. In this study, the electricity-system-wide direct financial costs and benefits in South Africa from the first 1 000 MW of PV that came online in 2014 are quantified. The two effects of PV...

  9. DOE Request for Information (RFI) DE-FOA-0000153 PV Manufacturing Initiative

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2010-02-01

    This draft report summarizes the results of the U.S. Department of Energy PV Manufacturing Request for Information (RFI), DE-FOA-0000153, that was released in September 2009. The PV Manufacturing Initiative is intended to help facilitate the development of a strong PV manufacturing industry in the United States.

  10. Household photovoltaic market in Xining, Qingha province, China: the role of local PV business

    Energy Technology Data Exchange (ETDEWEB)

    Ling, S.; Boardman, B. [University of Oxford (United Kingdom). Environmental Change Institute; Twidell, J. [University of Reading (United Kingdom). Dept. of Engineering; AMSET Centre, Horninghold (United Kingdom)

    2002-10-01

    This paper assesses the present and future market for household photovoltaic (PV) systems in rural Northwest China, especially from the PV commerce at Xining, Qinghai Province. This unsubsidised free market is now met by the emerging PV industry in China, which includes cell and module manufacturers, and PV system distributors and assemblers. For widespread deployment of such a renewable energy technology, the development of a local free market seems more successful than donor- or 'government subsidy'-driven programmes. Presently, there is a thriving infant PV industry in Northwest China, mostly centred in Xining. Xining-based PV sales companies have extensive networks for selling, marketing and servicing household PV systems for rural farmers and nomads. Small systems are now ordinary items on sale in local shops. Based on interviews and fieldwork observations with seven major PV sales companies in Xining, the household PV market is assessed from the present business operations of these companies. Detail of primary sources is given with the aim of archiving seminal progress in the history of photovoltaic power. The results suggest that although the household PV market will continue to grow, current government and international sponsored PV programmes can create both opportunities and barriers for the infant PV market an industry in China. (author)

  11. Defining Bankability for Each Step of a PV Project Using IECRE

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2016-07-12

    How can a PV customer know whether a PV plant is 'good'? IECRE was created to provide a cost-effective way to identify 'good' PV plants. This presentation describes the motivation, strategy, and status of the IECRE effort as of July, 2016.

  12. Evaluating the Technical and Economic Performance of PV Plus Storage Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Denholm, Paul L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Eichman, Joshua D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-08-17

    The decreasing costs of both PV and energy storage technologies have raised interest in the creation of combined PV plus storage systems to provide dispatchable energy and reliable capacity. In this study, we examine the tradeoffs among various PV plus storage configurations and quantify the impact of configuration on system net value.

  13. Integrated Three-Port DC-DC Converter for Photovoltaic (PV) Battery Stand-alone Systems

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    Several power sources such as PV solar arrays and battery are often used to manage the power flow for a photovoltaic (PV) based stand-alone power system due to the fluctuation nature of solar energy resource, and deliver a continuous power to the users in an appropriate form. Traditionally, three...... for PV and battery stand-alone system....

  14. Method for Load Sharing and Power Management in a Hybrid PV/Battery Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.

    2016-01-01

    This paper presents a decentralized load sharing and power management method for an islanded microgrid composed of PV units, battery units and hybrid PV/battery units. The proposed method performs all the necessary tasks such as load sharing among the units, battery charging and discharging and PV...

  15. Large Scale Solar Power Integration in Distribution Grids: PV Modelling, Voltage Support and Aggregation Studies

    NARCIS (Netherlands)

    Samadi, A.

    2014-01-01

    Long term supporting schemes for photovoltaic (PV) system installation have led to accommodating large numbers of PV systems within load pockets in distribution grids. High penetrations of PV systems can cause new technical challenges, such as voltage rise due to reverse power flow during light load

  16. Soft Computing Module of High Step-Up DC–DC Converter for PV Module using Simulink Environment

    Directory of Open Access Journals (Sweden)

    K. Vinoth Kumar

    2012-12-01

    Full Text Available Within the photovoltaic (PV power-generation market, the  PV module has shown obvious growth. However, a high voltage gain converter is essential for the module’s grid connection through a dc–ac inverter. This paper proposes a converter that employs a floating active switch to isolate energy from the PV panel when the ac module is OFF; this particular design protects installers and users from electrical hazards. Without extreme duty ratios and the numerous turns-ratios of a coupled inductor, this converter achieves a high step-up voltage-conversion ratio; the leakage inductor energy of the coupled inductor is efficiently recycled to the load. These features explain the module’s high-efficiency performance. The detailed operating principles and steady-state analyses of continuous, discontinuous, and boundary conduction modes are described. A 15V input voltage, 200V output voltage, and 100W output power prototype circuit of the proposed converter has been implemented; its maximum efficiency is up to 95.3% and full-load efficiency is 92.3%.

  17. Experimental comparison of PV-smoothing controllers using distributed generators

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean; Ellis, Abraham; Denda, Atsushi; Morino, Kimio; Hawkins, John N.; Arellano, Brian; Shinji, Takao; Ogata, Takao; Tadokoro, Masayuki

    2014-02-01

    The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

  18. Models for a stand-alone PV system[Photovoltaic

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Hansen, L.H.; Bindner, H.

    2000-12-01

    This report presents a number of models for modelling and simulation of a stand-alone photovoltaic (PV) system with a battery bank verified against a system installed at Risoe National Laboratory. The work has been supported by the Danish Ministry of Energy, as a part of the activities in the Solar Energy Centre Denmark. The study is carried out at Risoe National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PV system, namely solar cells, battery, controller, inverter and load. The models for PV module and battery are based on the model descriptions found in the literature. The battery model is developed at UMASS and is known as the Kinetic Battery Model (KiBaM). The other component models in the PV system are based on simple electrical knowledge. The implementation is done using Matlab/Simulink, a simulation program that provides a graphical interface for building models as modular block diagrams. The non-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements. The performance of the best linear Black box model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risoe. (au)

  19. Analysis of Leakage Current and DC Injection in Transformerless PV Inverter Topologies

    Directory of Open Access Journals (Sweden)

    Anjali Varghese C

    2014-03-01

    Full Text Available Considering low efficiencies of solar panels, the reliability and efficiency of power electronic interface has to be ensured. Transformerless PV inverters increases the efficiency by nearly 2% and decreases cost by 25%. With no galvanic isolation comes the problem of dc injection and ground leakage current which pauses serious problems to core saturation of distribution transformers, cable corrosion, Power quality and EMI problems and has to be limited as per IEEE standards. This paper gives an analysis of leakage current flowing through the parasitic capacitance and also the DC injection in the output of the inverter. Analysis is done for various values of parasitic capacitance. Five different HBridge derived topologies and PWM techniques are evaluated on the basis of leakage current and DC injection.

  20. Technical monitoring of PV systems in Apeldoorn, Netherlands. September 1997 - September 1999; Technische monitoring van PV-systemen te Apeldoorn. Periode september 1997 - september 1999

    Energy Technology Data Exchange (ETDEWEB)

    Van der Borg, N.J.C.M.; Jansen, M.J. [ECN Zon en Wind, Petten (Netherlands)

    2000-01-01

    Under contract from a Dutch energy distribution company (NUON), ECN is carrying out a monitoring program for a number of PV systems that are installed on houses in the urban area 'Het Woudhuis' in Apeldoorn, Netherlands. It concerns four groups of houses with PV systems which differ from each other in type of PV system or the orientation of the roofs. This document is a report of the technical monitoring concerning one group, comprising of 14 PV systems, during the period from 5 September 1997 to 4 September 1999. The average yield of the PV systems, standardized for a climatological average year for the Netherlands, is 706 kWh/kW{sub p}. An expanded monitoring program was carried out for one of the systems, which has led to detailed information about the incoming radiation, the behaviour of the PV panels and the inverter. 4 refs.

  1. PV-Optitag 2 - 1. phase: Development of CO{sub 2} neutral buildings; PV-Optitag 2 - 1. etape: Udvikling af CO{sub 2} neutrale boliger

    Energy Technology Data Exchange (ETDEWEB)

    Vejsig Pedersen, P.

    2008-04-15

    An integrated PV cell-solar heating roof solution called PV Optitag was developed in close cooperation between architects and engineers to make new CO{sub 2} neutral solutions for urban development projects. A CO{sub 2} neutral rooftop apartment with PV cells in a solar-energy roof exploits an air-based PVT PV-cell solution in combination with a heat pump as well as PV cells integrated into windows. The idea behind the apartment is a zero-energy solution in new buildings or an urban development component, and the apartment has been exhibited in Orestaden, see www.soltag.net. The project gained practical experience in fluid-covered PV cells in combination with heat pumps in housing. (author)

  2. Consequences of Reducing the Cost of PV Modules on a PV Wind Diesel Hybrid System with Limited Sizing Components

    Directory of Open Access Journals (Sweden)

    Jones S. Silva

    2012-01-01

    Full Text Available The use of renewable resources for power supply in family homes has passed the stage of utopia to became a reality, with limits set by technical and economic parameters. This paper presents the results of a project originated from the initiative of a middle-class family to achieve energy independence at home. The starting point was the concept of home with “zero energy” in which the total energy available is equal to the energy consumed. The solution devised to meet the energy demand of the residence in question is a PV wind diesel hybrid system connected to the grid, with the possibility of energy storage in batteries and in the form of heating water and the environment of the house. As a restriction, the family requested that the system would represent little impact to the lifestyle and landscape. This paper aims to assess the consequences of reductions in the cost of the PV modules on the optimization space, as conceived by the software Homer. The results show that for this system, a 50% reduction in the cost of PV modules allows all viable solutions including PV modules.

  3. Update of the Dutch PV specific yield for determination of PV contribution to renewable energy production: 25% more energy!

    NARCIS (Netherlands)

    van Sark, Wilfried; Bosselaar, L.; Gerrissen, P.; Esmeijer, K.B.D.; Moraitis, Panagiotis; van den Donker, M.; Emsbroek, G.

    2014-01-01

    Statistics Netherlands (CBS) annually publishes the contribution of renewables to the Dutch electricity supply, by following a national protocol. The amount of electricity generated by photovoltaic (PV) technology is calculated from the average installed capacity in a particular year multiplied by a

  4. Molecular cloning and characterization of a phytochelatin synthase gene, PvPCS1, from Pteris vittata L.

    Science.gov (United States)

    Dong, Ruibin; Formentin, Elide; Losseso, Carmen; Carimi, Francesco; Benedetti, Piero; Terzi, Mario; Schiavo, Fiorella Lo

    2005-12-01

    Pteris vittata L. is a staggeringly efficient arsenic hyperaccumulator that has been shown to be capable of accumulating up to 23,000 microg arsenic g(-1), and thus represents a species that may fully exploit the adaptive potential of plants to toxic metals. However, the molecular mechanisms of adaptation to toxic metal tolerance and hyperaccumulation remain unknown, and P. vittata genes related to metal detoxification have not yet been identified. Here, we report the isolation of a full-length cDNA sequence encoding a phytochelatin synthase (PCS) from P. vittata. The cDNA, designated PvPCS1, predicts a protein of 512 amino acids with a molecular weight of 56.9 kDa. Homology analysis of the PvPCS1 nucleotide sequence revealed that it has low identity with most known plant PCS genes except AyPCS1, and the homology is largely confined to two highly conserved regions near the 5'-end, where the similarity is as high as 85-95%. The amino acid sequence of PvPCS1 contains two Cys-Cys motifs and 12 single Cys, only 4 of which (Cys-56, Cys-90/91, and Cys-109) in the N-terminal half of the protein are conserved in other known PCS polypeptides. When expressed in Saccharomyces cerevisae, PvPCS1 mediated increased Cd tolerance. Cloning of the PCS gene from an arsenic hyperaccumulator may provide information that will help further our understanding of the genetic basis underlying toxic metal tolerance and hyperaccumulation.

  5. Characterisation of the mgo operon in Pseudomonas syringae pv. syringae UMAF0158 that is required for mangotoxin production

    Directory of Open Access Journals (Sweden)

    Arrebola Eva

    2012-01-01

    Full Text Available Abstract Background Mangotoxin is an antimetabolite toxin that is produced by strains of Pseudomonas syringae pv. syringae; mangotoxin-producing strains are primarily isolated from mango tissues with symptoms of bacterial apical necrosis. The toxin is an oligopeptide that inhibits ornithine N-acetyl transferase (OAT, a key enzyme in the biosynthetic pathway of the essential amino acids ornithine and arginine. The involvement of a putative nonribosomal peptide synthetase gene (mgoA in mangotoxin production and virulence has been reported. Results In the present study, we performed a RT-PCR analysis, insertional inactivation mutagenesis, a promoter expression analysis and terminator localisation to study the gene cluster containing the mgoA gene. Additionally, we evaluated the importance of mgoC, mgoA and mgoD in mangotoxin production. A sequence analysis revealed an operon-like organisation. A promoter sequence was located upstream of the mgoB gene and was found to drive lacZ transcription. Two terminators were located downstream of the mgoD gene. RT-PCR experiments indicated that the four genes (mgoBCAD constitute a transcriptional unit. This operon is similar in genetic organisation to those in the three other P. syringae pathovars for which complete genomes are available (P. syringae pv. syringae B728a, P. syringae pv. tomato DC3000 and P. syringae pv. phaseolicola 1448A. Interestingly, none of these three reference strains is capable of producing mangotoxin. Additionally, extract complementation resulted in a recovery of mangotoxin production when the defective mutant was complemented with wild-type extracts. Conclusions The results of this study confirm that mgoB, mgoC, mgoA and mgoD function as a transcriptional unit and operon. While this operon is composed of four genes, only the last three are directly involved in mangotoxin production.

  6. Results from measurements on the PV-VENT systems at Lundebjerg[DENMARK

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.

    2001-05-01

    The objective of the PV-VENT project was research, development, and tests in the following areas: 1. Develop and illustrate different ways of architectural integration of solar energy systems with combined PV power production and pre-heating of ventilation air in buildings, 2. Investigate the potential in pre-heating fresh air to the building by cooling the PV-panels with the fresh air and further to determine how much this cooling will increase the electrical performance of the PV-panels, 3. Develop and test air to air heat exchangers with an efficiency of 80% or above, 4. Develop and test fans and ventilation systems with an overall fan power demand of about 35 W, 5. Develop and test a direct coupling of the PV-panels to the fans in order to avoid the losses in an inverter, 6. Develop and test different ventilation systems utilizing the abovementioned features. Three different ways of integrating PV-panels with pre-heating of fresh air to the building have been demonstrated in Lundebjerg: a large PV-gable with amorphous PV-panels, a PV-facade with polycrystalline (c-Si) PV-panels and solar ventilation chimneys with polycrystalline (c-Si) PV-panels. Especially the latter feature, the solar ventilation chimney is a new and interesting concept as it allows for increased PV areas although the orientation of the building is not optimal for utilization of solar energy, as was the case in Lundebjerg. It is believed that the PV-VENT project has added important information and experience to the field of combining PV and ventilation systems. Information and experience that future systems of this type may benefit from. Several of the components from the project are believed to be able to contribute to set the standards for future PV and ventilation systems. Several of the components from the project is today commercial available and are used in ordinary building projects. (BA)

  7. Detecting loss mechanisms of c-Si PV modules in-situ I-V measurement

    Science.gov (United States)

    Guo, Siyu; Schneller, Eric; Walters, Joe; Davis, Kristopher O.; Schoenfeld, Winston V.

    2016-09-01

    PV module reliability is alsways an important issue for PV industry. In an outdoor PV system, PV modules suffer from degradation due to different factors. It is then very important to determine the loss mechanisms of a PV module and making improvement based on this. It is found in this work that due to mismatch effect, using fitting method to extract I-V characteristics might not be well applied on a PV module, especially when it has non-uniform degradation problem. This work proposes a method to accurately quantify the power loss of PV modules due to different degradation mechanisms, including series resistance (Rs) loss, non-uniform shunting loss and number of shunted cells, uniform shunting loss, uniform current loss, non-uniform current (mismatch) loss, recombination current (J01 and J02) losses of a PV module. All required input information are the measured current-voltage (I-V) curves and short circuit current- open circuit voltage (Isc-Voc) of PV module initial state and final state. The method is first applied to a simulated PV module with various degradation problems. Power loss due to each loss mechanism for the simulated PV module is then extracted using the proposed method and a pie chart can be generated. Comparing with the actual power loss on each loss mechanism, the method proposed in this work is proved to be very accurate. The method is then further applied to a degradated PV module istalled in an outdoor PV system. The power loss on series resistance, shunting and current mismatch are effectively identified and the number of shunted cells is accurately calculated. In the real application, this method can be used in both indoor and outdoor characterization, which can be very beneficial for PV degradation analysis of PV modules and systems.

  8. Integrating High Penetrations of PV into Southern California: Year 2 Project Update; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Mather, B.; Neal, R.

    2012-08-01

    Southern California Edison (SCE) is well into a five-year project to install a total of 500 MW of distributed photovoltaic (PV) energy within its utility service territory. Typical installations to date are 1-3 MW peak rooftop PV systems that interconnect to medium-voltage urban distribution circuits or larger (5 MW peak) ground-mounted systems that connect to medium-voltage rural distribution circuits. Some of the PV system interconnections have resulted in distribution circuits that have a significant amount of PV generation compared to customer load, resulting in high-penetration PV integration scenarios. The National Renewable Energy Laboratory (NREL) and SCE have assembled a team of distribution modeling, resource assessment, and PV inverter technology experts in order to investigate a few of the high-penetration PV distribution circuits. Currently, the distribution circuits being studied include an urban circuit with a PV penetration of approximately 46% and a rural circuit with a PV penetration of approximately 60%. In both cases, power flow on the circuit reverses direction, compared to traditional circuit operation, during periods of high PV power production and low circuit loading. Research efforts during year two of the five-year project were focused on modeling the distribution system level impacts of high-penetration PV integrations, the development and installation of distribution circuit data acquisition equipment appropriate for quantifying the impacts of high-penetration PV integrations, and investigating high-penetration PV impact mitigation strategies. This paper outlines these research efforts and discusses the following activities in more detail: the development of a quasi-static time-series test feeder for evaluating high-penetration PV integration modeling tools; the advanced inverter functions being investigated for deployment in the project's field demonstration and a power hardware-in-loop test of a 500-kW PV inverter implementing a

  9. Experimental Study on the Electric and Thermal Performance of PV/T System%PV/T系统电热性能的实验研究

    Institute of Scientific and Technical Information of China (English)

    鲁丹; 吕建

    2012-01-01

    介绍了PV/T系统组成的原理,针对PV/T系统的电热性能进行了实验研究,并对实验数据进行了处理.计算出了不同参数下该PV/T系统的热效率和电效率,分析了这些参数对系统热效率的影响,以及PV/T模块表面温度对系统电效率的影响.

  10. Residential Solar PV Planning in Santiago, Chile: Incorporating the PM10 Parameter

    Directory of Open Access Journals (Sweden)

    Gustavo Cáceres

    2014-12-01

    Full Text Available This paper addresses an economic study of the installation of photovoltaic (PV solar panels for residential power generation in Santiago, Chile, based on the different parameters of a PV system, such as efficiency. As a performance indicator, the Levelized Cost of Energy (LCOE was used, which indicates the benefit of the facility vs. the current cost of electrical energy. In addition, due to a high level of airborne dusts typically associated with PM10, the effect of the dust deposition on PV panels’ surfaces and the effect on panel performance are examined. Two different scenarios are analyzed: on-grid PV plants and off-grid PV plants.

  11. Effect of Reactive Power Management of PV Inverters on Need for Energy Storage

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob; Yang, Guangya

    2013-01-01

    Grid connected Photovoltaic (PV) systems are among the increasingly growing electric power generation units worldwide. The majority of new installations are expected to be residential PVs that are connected into distribution systems. However, the PV hosting capacity of low voltage (LV) grids...... is limited due to the voltage rise at the point of connection associated with the PV feed-in current. Reactive power management using PV inverters and using the electrical energy storage systems (EESS) are amongst the main solutions for increasing the PV hosting capacity in LV grids. In this paper, a method...

  12. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  13. Optimal design of NPC and Active-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    Targeting at a cost-effective deployment of grid-connected PhotoVoltaic (PV) systems, this paper presents a new methodology for the optimal design of transformerless PV inverters, which are based on the Neutral Point Clamped (NPC) and the Active-Neutral Point Clamped (ANPC) topologies. The design...... optimization results demonstrate that a different set of optimal values of the PV inverter switching frequency and output filter components are derived for the NPC and ANPC topologies, respectively, as well as for each of the PV inverter installation sites under study. The NPC and ANPC PV inverter structures...

  14. Very Thin Flexible Coupled Inductors for PV Module Integrated GaN Converter

    DEFF Research Database (Denmark)

    Acanski, Milos; Ouyang, Ziwei; Popovic-Gerber, Jelena

    2012-01-01

    proposed with more granular power processing by means of distributed maximum power point tracking (DMPPT). This is achieved by adjoining a MPPT unit to each PV module in the PV array. This paper presents a step further in the distributed power tracking approach, with a concept of very low profile power......As the PV energy penetrates into the urban area, shortcomings of the conventional centralized PV system architectures become more pronounced under the influence of urban environment with shading, soiling and orientation mismatch issues. To overcome these limitations new PV system architectures were...

  15. Very Thin Flexible Coupled Inductors for PV Module Integrated GaN Converter

    DEFF Research Database (Denmark)

    Acanski, Milos; Ouyang, Ziwei; Popovic-Gerber, Jelena;

    2012-01-01

    As the PV energy penetrates into the urban area, shortcomings of the conventional centralized PV system architectures become more pronounced under the influence of urban environment with shading, soiling and orientation mismatch issues. To overcome these limitations new PV system architectures were...... proposed with more granular power processing by means of distributed maximum power point tracking (DMPPT). This is achieved by adjoining a MPPT unit to each PV module in the PV array. This paper presents a step further in the distributed power tracking approach, with a concept of very low profile power...

  16. PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Valentini, Massimo;

    2008-01-01

    This paper concerns the evaluation of performance of grid-connected PV inverters in terms of conversion efficiency, European efficiency, static and dynamic MPP efficiency. Semi-automated tests were performed in the PV laboratory of the Institute of Energy Technology at the Aalborg University...... (Denmark) on a commercial transformerless PV inverter. Thanks to the available experimental test setups, that provide the required high measuring accuracy, and the developed PV simulator, which is required for MPPT performance evaluation, PV Inverters can be pretested before being tested by accredited...

  17. Sensitivity of Rooftop PV Projections in the SunShot Vision Study to Market Assumptions

    Energy Technology Data Exchange (ETDEWEB)

    Drury, E.; Denholm, P.; Margolis, R.

    2013-01-01

    The SunShot Vision Study explored the potential growth of solar markets if solar prices decreased by about 75% from 2010 to 2020. The SolarDS model was used to simulate rooftop PV demand for this study, based on several PV market assumptions--future electricity rates, customer access to financing, and others--in addition to the SunShot PV price projections. This paper finds that modeled PV demand is highly sensitive to several non-price market assumptions, particularly PV financing parameters.

  18. Solar Photovoltaic Economic Development: Building and Growing a Local PV Industry, August 2011 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2011-08-01

    The U.S. photovoltaic (PV) industry is forecast to grow, and it represents an opportunity for economic development and job creation in communities throughout the United States. This report helps U.S. cities evaluate economic opportunities in the PV industry. It serves as a guide for local economic development offices in evaluating their community?s competitiveness in the solar PV industry, assessing the viability of solar PV development goals, and developing strategies for recruiting and retaining PV companies to their areas.

  19. A Novel Frequency Restoring Strategy of Hydro-PV Hybrid Microgrid

    DEFF Research Database (Denmark)

    Wei, Feng; Kai, Sun; Guan, Yajuan

    2014-01-01

    The conventional PV systems based on the voltage inverters only inject dispatched power to the utility grid when they work at a grid-connected mode in the hydro-PV hybrid microgrid. Due to the droop method employed for load sharing between generators, as well as the enormous inertia of system....... The existence of frequency steady-state error and the slow active power/frequency dynamic response are inevitable. Therefore, a novel frequency restoring strategy for the hydro-PV hybrid microgrid based on the improved hierarchical control of PV systems is proposed in this paper. The output active power of PV...

  20. A Software Tool for Optimal Sizing of PV Systems in Malaysia

    Directory of Open Access Journals (Sweden)

    Tamer Khatib

    2012-01-01

    Full Text Available This paper presents a MATLAB based user friendly software tool called as PV.MY for optimal sizing of photovoltaic (PV systems. The software has the capabilities of predicting the metrological variables such as solar energy, ambient temperature and wind speed using artificial neural network (ANN, optimizes the PV module/ array tilt angle, optimizes the inverter size and calculate optimal capacities of PV array, battery, wind turbine and diesel generator in hybrid PV systems. The ANN based model for metrological prediction uses four meteorological variables, namely, sun shine ratio, day number and location coordinates. As for PV system sizing, iterative methods are used for determining the optimal sizing of three types of PV systems, which are standalone PV system, hybrid PV/wind system and hybrid PV/diesel generator system. The loss of load probability (LLP technique is used for optimization in which the energy sources capacities are the variables to be optimized considering very low LLP. As for determining the optimal PV panels tilt angle and inverter size, the Liu and Jordan model for solar energy incident on a tilt surface is used in optimizing the monthly tilt angle, while a model for inverter efficiency curve is used in the optimization of inverter size.

  1. How PV system ownership can impact the market value of residential homes

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Johnson, Jamie L. [Energy Sense Finance, LLC, Punta Gorda, FL (United States)

    2014-01-01

    There are multiple ways for a homeowner to obtain the electricity generating and savings benefits offered by a photovoltaic (PV) system. These include purchasing a PV system through various financing mechanisms, or by leasing the PV system from a third party with multiple options that may include purchase, lease renewal or PV system removal. The different ownership options available to homeowners presents a challenge to appraisal and real estate professionals during a home sale or refinance in terms of how to develop a value that is reflective of the PV systems operational characteristics, local market conditions, and lender and underwriter requirements. This paper presents these many PV system ownership options with a discussion of what considerations an appraiser must make when developing the contributory value of a PV system to a residential property.

  2. Characterization of Pseudomonas syringae pv. syringae, Causal Agent of Citrus Blast of Mandarin in Montenegro.

    Science.gov (United States)

    Ivanović, Žarko; Perović, Tatjana; Popović, Tatjana; Blagojević, Jovana; Trkulja, Nenad; Hrnčić, Snježana

    2017-02-01

    Citrus blast caused by bacterium Pseudomonas syringae is a very important disease of citrus occuring in many areas of the world, but with few data about genetic structure of the pathogen involved. Considering the above fact, this study reports genetic characterization of 43 P. syringae isolates obtained from plant tissue displaying citrus blast symptoms on mandarin (Citrus reticulata) in Montenegro, using multilocus sequence analysis of gyrB, rpoD, and gap1 gene sequences. Gene sequences from a collection of 54 reference pathotype strains of P. syringae from the Plant Associated and Environmental Microbes Database (PAMDB) was used to establish a genetic relationship with our isolates obtained from mandarin. Phylogenetic analyses of gyrB, rpoD, and gap1 gene sequences showed that P. syringae pv. syringae causes citrus blast in mandarin in Montenegro, and belongs to genomospecies 1. Genetic homogeneity of isolates suggested that the Montenegrian population might be clonal which indicates a possible common source of infection. These findings may assist in further epidemiological studies of this pathogen and for determining mandarin breeding strategies for P. syringae control.

  3. Characterization of Pseudomonas syringae pv. syringae, Causal Agent of Citrus Blast of Mandarin in Montenegro

    Science.gov (United States)

    Ivanović, Žarko; Perović, Tatjana; Popović, Tatjana; Blagojević, Jovana; Trkulja, Nenad; Hrnčić, Snježana

    2017-01-01

    Citrus blast caused by bacterium Pseudomonas syringae is a very important disease of citrus occuring in many areas of the world, but with few data about genetic structure of the pathogen involved. Considering the above fact, this study reports genetic characterization of 43 P. syringae isolates obtained from plant tissue displaying citrus blast symptoms on mandarin (Citrus reticulata) in Montenegro, using multilocus sequence analysis of gyrB, rpoD, and gap1 gene sequences. Gene sequences from a collection of 54 reference pathotype strains of P. syringae from the Plant Associated and Environmental Microbes Database (PAMDB) was used to establish a genetic relationship with our isolates obtained from mandarin. Phylogenetic analyses of gyrB, rpoD, and gap1 gene sequences showed that P. syringae pv. syringae causes citrus blast in mandarin in Montenegro, and belongs to genomospecies 1. Genetic homogeneity of isolates suggested that the Montenegrian population might be clonal which indicates a possible common source of infection. These findings may assist in further epidemiological studies of this pathogen and for determining mandarin breeding strategies for P. syringae control. PMID:28167885

  4. 水稻白叶枯病菌GX1329基因组文库的构建及含编码TAL效应物基因的克隆的分离%Construction of a Genomic Library of Xanthomonas oryzae pv. oryzae Strain GX1329 and Isolation of Clones Containing the Genes Encoding TAL Ef- fectors

    Institute of Scientific and Technical Information of China (English)

    张子宇; 赵帅; 莫伟兰; 罗雪梅; 玉延华; 段承杰; 冯家勋

    2011-01-01

    由革兰氏阴性细菌水稻白叶枯病菌引起的水稻白叶枯病是亚洲、北美以及非洲部分地区最严重的水稻病害之一,水稻白叶枯病可使水稻减产高达50%以上。研究表明水稻白叶枯病菌的毒力主要依靠三型分泌系统所分泌的效应物。为了解水稻白叶枯病菌广西菌株GX1329中含有avrBs3/pthA家族基因的情况,本研究应用Alu I部分酶切其基因组DNA,构建了含有736个克隆的菌株GX1329的基因组文库。BamHI酶切分析随机挑取的15个文库克隆表明,克隆的外源DNA随机性良好,克隆的最小片段为27.7kb,最大为58.5kb,平均大小为39.9kb,文库克隆容量约为2.8×10^3Mb,该文库中包含基因组中任一个基因的概率为99.4%。利用来自水稻白叶枯病菌菲律宾菌株PX086的无毒基因avrXa10的第252位~第486位核苷酸序列作为探针,通过菌落原位杂交从GX1329基因组文库中筛选到37个含avrBs3/pthA家族基因的克隆。再通过Southern杂交分析,得到了17个独立克隆。这17个克隆中至少含有13个不同的avrBs3/pthA家族基因。这些基因在GX1329基因组中有的单独存在,有的两个或两个以上串联存在。本工作基本上明确了菌株GX1329基因组中avrBs3/pthA家族基因的数量,为进一步研究菌株GX1329中avrBs3/pthA家族基因的功能奠定了基础。%Bacterial leaf blight (BLB), caused by Gram-negative bacterium Xanthomonas oryzae pv. oryzae (Xoo), is a serious threat to yield losses in the main regions of rice growth including Asia, North America and Africa. BLB could lead to a crop loss of up to 50%. It is known that the virulence of Xoo mainly relies on type BI secre- tion system (T3SS) and its secreted effectors. To know the numbers of genes encoding avrBs3/pthA family mem- bers in Guangxi Xoo strain GX1329, a genomic DNA library containing 736 clones was successfully constructed by partially

  5. 水稻白叶枯病菌GX1329基因组文库的构建及含编码TAL效应物基因的克隆的分离%Construction of a Genomic Library of Xanthomonas oryzae pv.oryzae Strain GX1329 and Isolation of Clones Containing the Genes Encoding TAL Effectors

    Institute of Scientific and Technical Information of China (English)

    张子宇; 赵帅; 莫伟兰; 罗雪梅; 玉延华; 段承杰; 冯家勋

    2011-01-01

    Bacterial leaf blight (BLB), caused by Gram-negative bacterium Xanthomonas oryzae pv. oryzae (Xoo),is a serious threat to yield losses in the main regions of rice growth including Asia, North America and Africa.BLB could lead to a crop loss of up to 50%. It is known that the virulence of Xoo mainly relies on type Ⅲ secretion system (T3SS) and its secreted effectors. To know the numbers of genes encoding avrBs3/pthA family members in Guangxi Xoo strain GX1329, a genomic DNA library containing 736 clones was successfully constructed by partially digesting the genomic DNA with A lu Ⅰ . Restriction enzyme BamH Ⅰ digestion analysis of plasmids from 15 randomly chosen library clones showed that the cloned DNA in the genomic library was highly random.The size of the smallest cloned DNA in one clone was 27.7kb, the size of the biggest cloned DNA in one clone was 58.5 kb, and the average size of cloned DNA in one clone was 39.9 kb. The cloning capacity of the library is about 2.8x103 Mb with high randomness, and the probability of any one gene contained in the library was about 99.4%.Thirty-seven positive clones were screened out from the GX1329 genomic library by colony in situ hybridization using the 252th to 486th bp sequence of avrXa10 from Xoo strain PXO86 as probe. Southern hybridization analysis of the 17 clones showed that they contain at least 13 different avrBs3/pthA genes. The results also showed that the avrB.s3/pthA family genes occurred in individual or clusters in the genome of strain GX1329. This work defined the number of avrBs3/pthA family genes in the genome of GX1329, which may provide a solid basis for further studying the function of the genes.%由革兰氏阴性细菌水稻白叶枯病菌引起的水稻白叶枯病是亚洲、北美以及非洲部分地区最严重的水稻病害之一,水稻白叶枯病可使水稻减产高达50%以上.研究表明水稻白叶枯病菌的毒力主要依靠三型分泌系统所分泌的效应物.为了解

  6. High-Penetration PV Integration Handbook for Distribution Engineers

    Energy Technology Data Exchange (ETDEWEB)

    Seguin, Rich [Electrical Distribution Design, Blacksburg, VA (United States); Woyak, Jeremy [Electrical Distribution Design, Blacksburg, VA (United States); Costyk, David [Electrical Distribution Design, Blacksburg, VA (United States); Hambrick, Josh [Electrical Distribution Design, Blacksburg, VA (United States); Mather, Barry [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-01-01

    This handbook has been developed as part of a five-year research project which began in 2010. The National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed together to analyze the impacts of high-penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to leverage the experience that SCE and the project team would gain during the significant installation of 500 MW of commercial scale PV systems (1-5 MW typically) starting in 2010 and completing in 2015 within SCE’s service territory through a program approved by the California Public Utility Commission (CPUC).

  7. Selecting Solar: Insights into Residential Photovoltaic (PV) Quote Variation

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Carolyn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Before investing in a system, a prospective PV customer must not only have initial concept 'buy in,' but also be able to evaluate the tradeoffs associated with different system parameters. Prospective customers might need to evaluate disparate costs for each system attribute by comparing multiple bids. The difficulty of making such an evaluation with limited information can create a cognitive barrier to proceeding with the investment. This analysis leverages recently available data from EnergySage, an online solar marketplace, to offer the first data-driven characterization of quote variation faced by prospective PV customers, lending early insight into the decisions customers face once they have initial buy-in.

  8. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  9. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    , resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redis-tributed, and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device......Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved either by modifying the modulation schemes or adding extra power switching devices...... devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency....

  10. Scalable Optimization Methods for Distribution Networks with High PV Integration

    Energy Technology Data Exchange (ETDEWEB)

    Guggilam, Swaroop S.; Dall' Anese, Emiliano; Chen, Yu Christine; Dhople, Sairaj V.; Giannakis, Georgios B.

    2016-07-01

    This paper proposes a suite of algorithms to determine the active- and reactive-power setpoints for photovoltaic (PV) inverters in distribution networks. The objective is to optimize the operation of the distribution feeder according to a variety of performance objectives and ensure voltage regulation. In general, these algorithms take a form of the widely studied ac optimal power flow (OPF) problem. For the envisioned application domain, nonlinear power-flow constraints render pertinent OPF problems nonconvex and computationally intensive for large systems. To address these concerns, we formulate a quadratic constrained quadratic program (QCQP) by leveraging a linear approximation of the algebraic power-flow equations. Furthermore, simplification from QCQP to a linearly constrained quadratic program is provided under certain conditions. The merits of the proposed approach are demonstrated with simulation results that utilize realistic PV-generation and load-profile data for illustrative distribution-system test feeders.

  11. Models for a stand-alone PV system

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Hansen, L.H.;

    2001-01-01

    Energy Centre Denmark. The study is carried out at Risø National Laboratory with the main purpose to establish a library of simple mathematical models for each individual element of a stand-alone PVsystem, namely solar cells, battery, controller, inverter and load. The models for PV module and battery...... that provides a graphical interface for building models as modular block diagrams. Thenon-linear behaviour of the battery, observed in the measurements, is investigated and compared to the KiBaM model's performance. A set of linear Black box models are estimated based on the battery measurements....... The performance of the best linear Blackbox model is compared to the KiBaM model. A validation of each of the implemented mathematical model is performed by an interactive analysis and comparison between simulation results and measurements, acquired from the stand-alone PV system at Risø....

  12. Pseudomonas syringae pv. tabaci in papaya seedlings Pseudomonas syringae pv. tabaci em plântulas de mamoeiro

    Directory of Open Access Journals (Sweden)

    Luís Otávio S. Beriam

    2006-03-01

    Full Text Available The natural occurrence of Pseudomonas syringae pv. tabaci causing leaf spot symptoms in papaya seedlings is reported. The pathogen was identified through biochemical, physiological, serological, and molecular assays and artificial inoculations in papaya plants. It was also shown that the strains were pathogenic to bean and tobacco plants. The restriction patterns obtained with Afa I, Alu I, Dde I, Hae III, Hpa II, Hinf I, Sau 3A I and Taq I of the PCR-RFLP of 16S-23S DNAr were identical to the P. s. pv. tabaci patterns. Primers corresponding to hrpL gene of P. syringae were also tested and the results grouped the papaya strains with P s. pv. tabaci. Bacterial strains were deposited at Coleção de Culturas IBSBF, Instituto Biológico, Campinas, Brazil, under access numbers 1687 and 1822.É relatada a ocorrência natural de Pseudomonas syringae pv. tabaci causando sintomas de lesões foliares em plântulas de mamoeiro. O patógeno foi identificado por meio de testes bioquímicos, fisiológicos, serológicos e moleculares, além de ensaios de patogenicidade em plantas de mamoeiro, feijoeiro e fumo. Os padrões de restrição obtidos com as enzimas Afa I, Alu I, Dde I, Hae III, Hpa II, Hinf I, Sal 3A I e Taq I, utilizando-se a técnica de PCR-RLFP da região espaçadora 16S-23S do DNA ribossômico, foram idênticos àqueles apresentados para P. s. pv. tabaci. Primers correspondentes ao gene hrpL de P. syringae foram também testados e os resultados obtidos permitiram agrupar as linhagens isoladas de mamão com P. s. pv. tabaci. Linhagens bacterianas estão depositadas na coleção de culturas IBSBF, Instituto Biológico, Campinas, sob n. 1687 e 1822.

  13. Modeling and Control of DC/DC Boost Converter using K-Factor Control for MPPT of Solar PV System

    DEFF Research Database (Denmark)

    Vangari, Adithya; Haribabu, Divyanagalakshmi; Sakamuri, Jayachandra N.

    2015-01-01

    PV array, which includes the effect of solar insolation and temperature on PV array output, for the application in power system transient simulations, is also presented. The performance of the PV array model is verified with simulations at different atmospheric conditions. A 160W PV module from BP...

  14. Quantify Degradation Rates and Mechanisms of PV Modules and Systems Installed in Florida Through Comprehensive Experimental and Theoretical Analysis (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Sorloaica-Hickman, N.; Davis, K.; Kurtz, S.; Jordan, D.

    2011-02-01

    The economic viability of photovoltaic (PV) technologies is inextricably tied to both the electrical performance and degradation rate of the PV systems, which are the generators of electrical power in PV systems. Over the past 15 years, performance data have been collected on numerous PV systems installed throughout the state of Florida and will be presented.

  15. Pv rural electrification programme at the Bolivian high plateau

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzo, E.; Aguilera, J. [Instituto de Energia Solar, ETSI Telecomunicacion, (Spain)

    1995-12-31

    Since 1988 the Institute of Solar Energy of the Universidad Politecnica de Madrid is carrying out a pv rural electrification programme at the Bolivian high plateau. This programme has been focused in three aspects: the domestic electrification, users participation and transfer technology. At present, there are about 1,500 electrified dwellings distributed in the Bolivian high plateau. We have got deep knowledge about life style and organization of the aymara Indians who are the inhabitants of the working zone. We think that this knowledge can be very useful for a large scale introduction of PV solar energy in this region. Finally, we present a new way to transfer PV technology to developing countries. Thanks to this programme a group of aymara Indians is able to manufacture charge regulators and electronic ballast to use in the PV installations of the programme. [Espanol] Desde 1988 el Instituto de Energia Solar de la Universidad Politecnica de Madrid esta llevando a cabo un programa fotovoltaico de electrificacion rural en la altiplanicie Boliviana. Este programa ha sido enfocado a tres aspectos: la electrificacion domestica, la participacion de los usuarios y la transferencia de la tecnologia. Actualmente, hay alrededor de 1500 conjuntos habitacionales electrificados distribuidos en la altiplanicie Boliviana. Hemos obtenido un profundo conocimiento del estilo de vida y de la organizacion de los indios aymara que son los habitantes de la zona de trabajo. Pensamos que este conocimiento puede ser muy util para una introduccion en gran escala de la energia solar fotovoltaica en esta region. Finalmente, presentamos una nueva forma de transferir la tecnologia fotovoltaica a paises en desarrollo. Gracias a este programa un grupo de indios aymara pueden fabricar reguladores de carga y balastros electronicos para ser usados en instalaciones fotovoltaicas del programa.

  16. Assessment of genetic diversity of Xanthomonas oryzae pv. oryzae

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@Bacterial blight of rice, caused by Xanthomonas oryzae pv. Oryzae(Xoo. ), is one of the major rice diseases in China. Making clear the shift of genetic diversity of the pathogen will provide important information for rice breeding. Strains collected from 11 provinces located in Southern region of the Changjiang River in China were assessed by using inoculation method and IS-PCR(Insertion Sequence-Based Polymerase Chain Reaction) analysis.

  17. High Penetration PV: How High Can We Go?

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-01

    Brochure highlighting NREL's partnership with SolarCity and Hawaiian Electric (HECO) to increase the penetration of solar photovoltaics on the electricity grid. To better understand the potential impact of transient overvoltages due to load rejection, NREL collaborated with SolarCity and HECO to run a series of tests measuring the magnitude and duration of load rejection overvoltage events and demonstrating the ability of advanced PV inverters to mitigate their impacts.

  18. Modeling and Simulation for Hybrid of PV-Wind system

    Directory of Open Access Journals (Sweden)

    Maged N. F. Nashed

    2015-04-01

    Full Text Available The rising consumption rate of fossil fuels causes a significant pollution impact on the atmosphere, unwanted greenhouse gases has drawn worldwide attention towards renewable energy sources. Moreover, in recent year’s generation of electricity using the different types of renewable sources are specifically evaluated in the economical performance of the overall equipment. This paper focuses on the modeling and analysis of a Standalone Photovoltaic (PV- wind energy hybrid generation system under different conditions using MATLAB. The proposed system consists of two renewable sources i.e. wind and solar energy. Modeling of PV array and wind turbine is explained. The wind subsystem is equipped of an induction generator. In photovoltaic system, the variable DC output voltage is controlled using buck-boost converter for the MPPT. These two systems are combined to operate in parallel and the common bus collects the total energy from the wind and PV systems are uses it to the load and with change the load

  19. Pv rural electrification in Kiribati: A case study

    Energy Technology Data Exchange (ETDEWEB)

    Hurry, Suresh [Energy and Atmosphere Programme, SEED/BPPS UNDP, New York (United States)

    1995-12-31

    In collaboration with the Japan International Cooperation Agency (JICA), United Nations Development Programme (UNDP) participated in the implementation of a photovoltaic (PV) rural electrification project in Kiribati. Under this project, assistance was provided to the Kiribati Solar Energy Company (SEC) in order to enable it to provide electricity service as a micro utility in a effective manner. The assistance provided included installation of 55 PV-based solar home systems and one community system. In addition, the assistance focussed on technical training of SEC personnel on PV systems and management training on accounting, billing, spare parts inventory, etcetera. [Espanol] En colaboracion con la Japan International Cooperation Agency (JICA), el Programa de las Naciones Unidas para el Desarrollo (PNUD) participo en la puesta en practica de un proyecto de electrificacion rural fotovoltaico en Kiribati. Dentro de este proyecto, se proporciono ayuda a la Kiribati Solar Energy Company (SEC) para ponerla en condicion de suministrar el servicio electrico, en una forma efectiva, como una micro empresa electrica. La ayuda proporcionada incluyo la instalacion de 55 sistemas domesticos solares fotovoltaicos y un sistema comunitario. Adicionalmente, la ayuda se enfoco al entrenamiento tecnico del personal de SEC en sistemas fotovoltaicos y en el entrenamiento administrativo en contabilidad, facturacion, inventariado de partes de repuesto, etc.

  20. Sizing PV-wind hybrid energy system for lighting

    Directory of Open Access Journals (Sweden)

    Mustafa Engin

    2012-09-01

    Full Text Available Sizing of wind and photovoltaic generators ensures lower operational costs and therefore, is considered as an important issue. An approach for sizing along with a best management technique for a PV-wind hybrid system with batteries is proposed in this paper, in which the best size for every component of the system could be optimized according to the weather conditions and the load profile. The average hourly values for wind speed and solar radiation for Izmir, Turkey has been used in the design of the systems, along with expected load profile. A hybrid power model is also developed for battery operation according to the power balance between generators and loads used in the software, to anticipate performances for the different systems according to the different weather conditions. The output of the program will display the performance of the system during the year, the total cost of the system, and the best size for the PV-generator, wind generator, and battery capacity. Using proposed procedure, a 1.2 kWp PV-wind hybrid system was designed for Izmir, and simulated and measured results are presented.

  1. Predicatbility of windstorm Klaus; sensitivity to PV perturbations

    Science.gov (United States)

    Arbogast, P.; Maynard, K.

    2010-09-01

    It appears that some short-range weather forecast failures may be attributed to initial conditions errors. In some cases it is possible to anticipate the behavior of the model by comparison between observations and model analyses. In the case of extratropical cyclone development one may qualify the representation of the upper-level precursors described in terms of PV in the initial conditions by comparison with either satellite ozone or water-vapor. A step forward has been made in developing a tool based upon manual modifications of dynamical tropopause (i.e. height of 1.5 PV units) and PV inversion. After five years of experimentations it turns out that the forecasters eventually succeed in improving the forecast of some strong cyclone development. However the present approach is subjective per se. To measure the subjectivity of the procedure a set of 15 experiments has been performed provided by 7 different people (senior forecasters and scientists involved in dynamical meteorology) in order to improve an initial state of the global model ARPEGE leading to a poor forecast of the wind storm Klaus (24 January 2009). This experiment reveals that the manually defined corrections present common features but also a large spread.

  2. A Variable PV Broad Absorption Line and Quasar Outflow Energetics

    CERN Document Server

    Capellupo, Daniel M; Barlow, Tom A

    2014-01-01

    Broad absorption lines (BALs) in quasar spectra identify high velocity outflows that might exist in all quasars and could play a major role in feedback to galaxy evolution. The viability of BAL outflows as a feedback mechanism depends on their kinetic energies, as derived from the outflow velocities, column densities, and distances from the central quasar. We estimate these quantities for the quasar, Q1413+1143 (redshift $z_e = 2.56$), aided by the first detection of PV $\\lambda\\lambda$1118,1128 BAL variability in a quasar. In particular, PV absorption at velocities where the CIV trough does not reach zero intensity implies that the CIV BAL is saturated and the absorber only partially covers the background continuum source (with characteristic size 22.3 (cm^-2). Variability in the PV and saturated CIV BALs strongly disfavors changes in the ionization as the cause of the BAL variability, but supports models with high-column density BAL clouds moving across our lines of sight. The observed variability time of ...

  3. Comparative Study Between Wind and Photovoltaic (PV) Systems

    Science.gov (United States)

    Taha, Wesam

    This paper reviews two renewable energy systems; wind and photovoltaic (PV) systems. The common debate between the two of them is to conclude which one is better, in terms of cost and efficiency. Therefore, comparative study, in terms of cost and efficiency, is attempted. Regarding total cost of both, wind and PV systems, many parameters must be taken into consideration such as availability of energy (either wind or solar), operation and maintenance, availability of costumers, political influence, and the components used in building the system. The main components and parameters that play major role in determining the overall efficiency of wind systems are the wind turbine generator (WTG), gearbox and control technologies such as power, and speed control. On the other hand, in grid-connected PV systems (GCPVS), converter architecture along with maximum power point tracking (MPPT) algorithm and inverter topologies are the issues that affects the efficiency significantly. Cost and efficiency analyses of both systems have been carried out based on the statistics available till today and would be useful in the progress of renewable energy penetration throughout the world.

  4. Overcoming PV grid issues in the urban areas

    Energy Technology Data Exchange (ETDEWEB)

    Ehara, T.

    2009-10-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at grid issues in urban photovoltaic electricity and how to overcome them. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy as a significant and sustainable renewable energy option. The objective of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. The paper discusses the goal of mainstreaming PV systems in the urban environment. In this report, PV grid interconnection issues and countermeasures based on the latest studies are identified and summarised. Appropriate and understandable information is provided for all possible stakeholders. Possible impacts and benefits of PV grid interconnection are identified, technical measures designed to eliminate negative impacts and enhance possible benefits are presented. The status of research and demonstration projects is introduced and the latest outcomes are summarised. Recommendations and conclusions based on the review process are summarised and presented.

  5. Rooftop PV system. Final technical progress report, Phase II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    Under this four-year PV:BONUS Program, ECD and United Solar are developing and demonstrating two new lightweight flexible building integrated Photovoltaic (BIPV) modules specifically designed as exact replacements for conventional asphalt shingles and standing seam metal roofing. These modules can be economically and aesthetically integrated into new residential and commercial buildings, and address the even larger roofing replacement market. The modules are designed to be installed by roofing contractors without special training which minimizes the installation and balance of system costs. The modules will be fabricated from high-efficiency, multiple-junction a-Si alloy solar cells developed by ECD and United Solar. Under the Phase I Program, which ended in March 1994, we developed two different concept designs for rooftop PV modules: (1) the United Solar overlapping (asphalt shingle replacement) shingle-type modules and (2) the ECD metal roof-type modules. We also developed a plan for fabricating, testing and demonstrating these modules. Candidate demonstration sites for our rooftop PV modules were identified and preliminary engineering designs for these demonstrations were developed; a marketing study plan was also developed. The major objectives of the Phase II Program, which started in June 1994 was (1) to develop, test, and qualify these new rooftop modules; (2) to develop mechanical and electrical engineering specifications for the demonstration projects; and (3) to develop a marketing/commercialization plan.

  6. Characterization of Novel Bacteriophages for Biocontrol of Bacterial Blight in Leek Caused by Pseudomonas syringae pv. porri.

    Science.gov (United States)

    Rombouts, Sofie; Volckaert, Anneleen; Venneman, Sofie; Declercq, Bart; Vandenheuvel, Dieter; Allonsius, Camille N; Van Malderghem, Cinzia; Jang, Ho B; Briers, Yves; Noben, Jean P; Klumpp, Jochen; Van Vaerenbergh, Johan; Maes, Martine; Lavigne, Rob

    2016-01-01

    Pseudomonas syringae pv. porri, the causative agent of bacterial blight in leek (Allium porrum), is increasingly frequent causing problems in leek cultivation. Because of the current lack of control measures, novel bacteriophages were isolated to control this pathogen using phage therapy. Five novel phages were isolated from infected fields in Flanders (vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3, vB_PsyM_KIL4, and vB_PsyM_KIL5), and were complemented with one selected host range mutant phage (vB_PsyM_KIL3b). Genome analysis of the phages revealed genome sizes between 90 and 94 kb and an average GC-content of 44.8%. Phylogenomic networking classified them into a novel clade, named the "KIL-like viruses," related to the Felixounalikevirus genus, together with phage phiPsa374 from P. syringae pv. actinidiae. In vitro characterization demonstrated the stability and lytic potential of these phages. Host range analysis confirmed heterogeneity within P. syringae pv. porri, leading to the development of a phage cocktail with a range that covers the entire set of 41 strains tested. Specific bio-assays demonstrated the in planta efficacy of phages vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3, and vB_PsyM_KIL3b. In addition, two parallel field trial experiments on three locations using a phage cocktail of the six phages showed variable results. In one trial, symptom development was attenuated. These data suggest some potential for phage therapy in controlling bacterial blight of leek, pending optimization of formulation and application methods.

  7. Characterization of novel bacteriophages for biocontrol of bacterial blight in leek caused by Pseudomonas syringae pv. porri

    Directory of Open Access Journals (Sweden)

    Sofie eRombouts

    2016-03-01

    Full Text Available Pseudomonas syringae pv. porri, the causative agent of bacterial blight in leek (Allium porrum, is increasingly frequent causing problems in leek cultivation. Because of the current lack of control measures, novel bacteriophages were isolated to control this pathogen using phage therapy. Five novel phages were isolated from infected fields in Flanders (vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3, vB_PsyM_KIL4 and vB_PsyM_KIL5, and were complemented with one selected host range mutant phage (vB_PsyM_KIL3b. Genome analysis of the phages revealed genome sizes between 90 and 94 kb and an average GC-content of 44.8%. Phylogenomic networking classified them into a novel clade, named the ‘KIL-like viruses’, related to the Felixounalikevirus genus, together with phage phiPsa374 from Pseudomonas syringae pv. actinidiae. In vitro characterization demonstrated the stability and lytic potential of these phages. Host range analysis confirmed heterogeneity within P. syringae pv. porri, leading to the development of a phage cocktail with a range that covers the entire set of 41 strains tested. Specific bio-assays demonstrated the in planta efficacy of phages vB_PsyM_KIL1, vB_PsyM_KIL2, vB_PsyM_KIL3 and vB_PsyM_KIL3b. In addition, two parallel field trial experiments on three locations using a phage cocktail of the six phages showed variable results. In one trial, symptom development was attenuated. These data suggest some potential for phage therapy in controlling bacterial blight of leek, pending optimization of formulation and application methods.

  8. Reaction of cassava’s germoplasm to Xanthomonas axonopodis pv. manihots/ Reação de germoplasma de mandioca a Xanthomonas axonopodis pv. manihots

    Directory of Open Access Journals (Sweden)

    Benjamim de Melo

    2007-07-01

    Full Text Available The cassava is presented as an important stach source, mainly in the tropics. The bacteriosis disease caused by Xanthomonas axonopodis p.v. manihots is the most important disease of this culture and its damage can achieve 30% of the production, or even more. This work objectified to evaluate, in green house condition the reaction of “mandioca mansa” and the “mandioca brava” cassava’s germoplasma to the two isolates of Xanthomonas axonopodis p.v. manihots. Trials were developed at the Instituto de Ciências Agrárias da Universidade Federal de Uberlândia. The plants had been inoculated by seasor’s cuttings of three central leaflets in three completely opened new leaves, following by insertion of a little wood stick at the oldest leaf’s axel, using a bacterial suspension at 2x109u.f.c. mL-1. The inoculation happened at the 42nd day after planting and the evaluation at the 41st day after inoculation. The evaluation criteria were: notes of visual symptoms in the aerial part, percentages defoliation and systemic infection of the stalk. The results showed the efficiency of the evaluation criteria applied at this work for the isolates virulence study. The Uberlândia isolate was more virulent to “mandioca mansa” cassava cultivars and the Lavras isolate was more virulent to “mandioca brava” cassava cultivars. That indicates the need of using isolates from the region where the germoplasm will be cultivated. Considering the germoplasm resistance reaction analysis, both the sistemic infection precentage and the defoliation criteria presented as very effective. Oustanding behavior was observed for the Vassoura, Amarela, Vermelha and Castelinho cultivars and for the CPAC88-11 clone.A mandioca apresenta-se como importante fonte de carboidratos, principalmente nos trópicos. A bacteriose causada por Xanthomonas axonopodis p.v. manihots é a doença mais importante desta cultura e seus danos podem chegar a 30% ou mais na produção. Este

  9. Molecular detection of Xanthomonas oryzae pv.oryzae, Xanthomonas oryzae pv. oryzicola, and Burkholderia glumae in infected rice seeds and leaves

    Institute of Scientific and Technical Information of China (English)

    Wen; Lu; Luqi; Pan; Haijun; Zhao; Yulin; Jia; Yanli; Wang; Xiaoping; Yu; Xueyan; Wang

    2014-01-01

    The polymerase chain reaction(PCR) is particularly useful for plant pathogen detection. In the present study, multiplex PCR and SYBR Green real-time PCR were developed to facilitate the simultaneous detection of three important rice pathogens, Xanthomonas oryzae pv.oryzae, X. oryzae pv. oryzicola, and Burkholderia glumae. The unique PCR primer sets were designed from portions of a putative glycosyltransferase gene of X. oryzae pv. oryzae, an Avr Rxo gene of X. oryzae pv. oryzicola, and an internal transcribed spacer(ITS) sequence of B. glumae. Using a multiplex PCR assay, X. oryzae pv. oryzae, X. oryzae pv. oryzicola, and B. glumae were detected in one PCR reaction that contained the newly developed primer set mix. Using SYBR Green real-time PCR assays, X. oryzae pv. oryzae, X. oryzae pv. oryzicola, and B. glumae were detected at 1, 1, and 10 fg μL-1, respectively. These newly designed molecular assays are sensitive and could be reliable tools for pathogen detection and disease forecasting.

  10. Quantification, challenges and outlook of PV integration in the power system: a review by the European PV Technology Platform

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Baccaro, Federica; De Felice, Matteo;

    2015-01-01

    Integration in the power system has become a limiting factor to the further development of photovoltaics. Proper quantification is needed to evaluate both issues and solutions; the share of annual electricity demand is widely used but we found that some of the metrics which are related to power...... rather than energy better reflect the impact on networks. Barriers to wider deployment of PV into power grids can be split between local technical issues (voltage levels, harmonics distortion, reverse power flows and transformer loading) and system-wide issues (intermittency, reduction of system...... networks. Forecasting, storage, and combination with other renewable sources are interdependent solutions to solve the intermittency issue. Finally, we found that PV is also an opportunity to reduce some investment required to upgrade existing power networks. Through integration with micro-grids and hybrid...

  11. Quantification, challenges and outlook of PV integration in the power system: a review by the European PV Technology Platform

    DEFF Research Database (Denmark)

    Alet, Pierre-Jean; Baccaro, Federica; De Felice, Matteo;

    2015-01-01

    rather than energy better reflect the impact on networks. Barriers to wider deployment of PV into power grids can be split between local technical issues (voltage levels, harmonics distortion, reverse power flows and transformer loading) and system-wide issues (intermittency, reduction of system......Integration in the power system has become a limiting factor to the further development of photovoltaics. Proper quantification is needed to evaluate both issues and solutions; the share of annual electricity demand is widely used but we found that some of the metrics which are related to power...... networks. Forecasting, storage, and combination with other renewable sources are interdependent solutions to solve the intermittency issue. Finally, we found that PV is also an opportunity to reduce some investment required to upgrade existing power networks. Through integration with micro-grids and hybrid...

  12. Investigation of the Effect Temperature on Photovoltaic (PV Panel Output Performance

    Directory of Open Access Journals (Sweden)

    Amelia Razak

    2016-10-01

    Full Text Available The main limit of PV systems is the low conversion efficiency of PV panels, which is strongly influenced by their operating temperature. Lack of accuracy in consideration through PV panel temperature increases the financial risk of system installation. This present study investigates the effects of operating temperature on monocrystalline PV panel at Perlis, Malaysia. A selected model of PV panel firstly was simulated using PVSYST software in order to evaluate its output performance. Meanwhile, PROVA 200 used to measure and record all electrical data for outdoor experimental during the sunniest day. Besides, the thermal distribution was analysed through PV panel temperatures and thermal imaging. Simulation results implied that the output power of PV panel decreases with increasing of its working temperature followed by the efficiency. The experimental results obviously show that the STC parameters do not represent the real operating conditions of PV panel for outdoor conditions. Less output power was produced affected by the atmospheric factors such as solar irradiance and ambient temperature. These both factors strongly affected the PV panel temperature distribution. In short, the elevating of PV panel temperature contributed to the negative impact on output performance of the panel.

  13. A Non-Modeling Exploration of Residential Solar Photovoltaic (PV) Adoption and Non-Adoption

    Energy Technology Data Exchange (ETDEWEB)

    Sigrin, Benjamin O. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moezzi, Mithra [Portland State Univ., Portland, OR (United States); Ingle, Aaron [Portland State Univ., Portland, OR (United States); Lutzenhiser, Loren [Portland State Univ., Portland, OR (United States)

    2017-09-01

    Although U.S. deployment of residential rooftop solar photovoltaic (PV) systems has accelerated in recent years, PV is still installed on less than 1 percent of single-family homes. Most research on household PV adoption focuses on scaling initial markets and modeling predicted growth rather than considering more broadly why adoption occurs. Among the studies that have investigated the characteristics of PV adoption, most collected data from adopters, sometimes with additional non-adopter data, and rarely from people who considered but did not adopt PV. Yet the vast majority of Americans are non-adopters, and they are a diverse group - understanding their ways of evaluating PV adoption is important. Similarly, PV is a unique consumer product, which makes it difficult to apply findings from studies of other technologies to PV. In addition, little research addresses the experience of households after they install PV. This report helps fill some of these gaps in the existing literature. The results inform a more detailed understanding of residential PV adoption, while helping ensure that adoption is sufficiently beneficial to adopters and even non-adopters.

  14. EcPV2 DNA in equine genital squamous cell carcinomas and normal genital mucosa.

    Science.gov (United States)

    Bogaert, Lies; Willemsen, Anouk; Vanderstraeten, Eva; Bracho, Maria A; De Baere, Cindy; Bravo, Ignacio G; Martens, Ann

    2012-07-01

    Squamous cell carcinoma (SCC) represents the most common genital malignant tumor in horses. Similar to humans, papillomaviruses (PVs) have been proposed as etiological agents and recently Equine papillomavirus type 2 (EcPV2) has been identified in a subset of genital SCCs. The goals of this study were (1) to determine the prevalence of EcPV2 DNA in tissue samples from equine genital SCCs, penile intraepithelial neoplasia (PIN) and penile papillomas, using EcPV2-specific PCR, (2) to examine the prevalence of latent EcPV2 infection in healthy genital mucosa and (3) to determine genetic variability within EcPV2 and to disentangle phylogenetic relationships of EcPV2 among PVs. EcPV2 DNA was detected in all but one penile SCC (15/16), in all PIN lesions (8/8) and penile papillomas (4/4). Additionally, EcPV2 DNA was demonstrated in one of two metastasized lymph nodes, one contact metastasis in the mouth, two vaginal and one anal lesion. In healthy horses, EcPV2 DNA was detected in 10% (4/39) of penile swabs but in none of vulvovaginal swabs (0/20). This study confirms the presence of EcPV2 DNA in equine genital SCCs and shows its involvement in anal lesions, a lymph node and contact metastases. Latent EcPV2 presence was also shown in normal male genital mucosa. We found that different EcPV2 variants cocirculate among horses and that EcPV2 is related to the Delta+Zeta PVs and is only a very distant relative of high-risk human PVs causing genital cancer. Thus, similar viral tropism and similar malignant outcome of the infection do not imply close evolutionary relationship.

  15. Chemical characterization of bioactive compounds from the endophytic fungus Diaporthe helianthi isolated from Luehea divaricata

    Directory of Open Access Journals (Sweden)

    Vânia Specian

    2012-09-01

    Full Text Available Endophytic microorganisms, defined as fungi or bacteria that colonize the interior of plants without causing any immediate negative effects or damages, have reciprocal relationships with host plants. In some cases their presence is beneficial to the host due to the synthesis of bioactive compounds, among which several alcohols, esters, ketones and others that may react with other compounds and may be lethal to pathogenic microorganisms. Diaporthe helianthi (Phomopsis helianthi in its anamorphic phase is available worldwide, especially in Europe, Asia and America. Isolated in Europe as an agent of the sunflower stem cancer, it has also been endophytically isolated from tropical and temperate plants. A D. helianthi strain isolated from Luehea divaricata has been employed in current research. An investigation of the secondary metabolite from D. helianthi by CC and NMR of ¹H and 13C yielded the separation of 10 fractions and the identification of the phenolic compound 2(-4 hydroxyphenyl-ethanol (Tyrosol. Its antimicrobial reaction was tested and the ensuing antagonistic effects on the human pathogenic bacteria Enterococcus hirae, Escherichia coli, Micrococcus luteus, Salmonella typhi, Staphylococcus aureus, phytopathogenic Xanthomonas asc. phaseoli and phytopathogenic fungi were demonstrated. Results show that bioactive compounds and Tyrosol produced by D. helianthi have a biotechnological potential.

  16. Spatial variation in genetic diversity and natural selection on the thrombospondin-related adhesive protein locus of Plasmodium vivax (PvTRAP.

    Directory of Open Access Journals (Sweden)

    Rattiporn Kosuwin

    Full Text Available Thrombospondin-related adhesive protein (TRAP of malaria parasites is essential for sporozoite motility and invasions into mosquito's salivary gland and vertebrate's hepatocyte; thereby, it is a promising target for pre-erythrocytic vaccine. TRAP of Plasmodium vivax (PvTRAP exhibits sequence heterogeneity among isolates, an issue relevant to vaccine development. To gain insights into variation in the complete PvTRAP sequences of parasites in Thailand, 114 vivax malaria patients were recruited in 2006-2007 from 4 major endemic provinces bordering Myanmar (Tak in the northwest, n = 30 and Prachuap Khirikhan in the southwest, n = 25, Cambodia (Chanthaburi in the east, n = 29 and Malaysia (Yala and Narathiwat in the south, n = 30. In total, 26 amino acid substitutions were detected and 9 of which were novel, resulting in 44 distinct haplotypes. Haplotype and nucleotide diversities were lowest in southern P. vivax population while higher levels of diversities were observed in other populations. Evidences of positive selection on PvTRAP were demonstrated in domains II and IV and purifying selection in domains I, II and VI. Genetic differentiation was significant between each population except that between populations bordering Myanmar where transmigration was common. Regression analysis of pairwise linearized Fst and geographic distance suggests that P. vivax populations in Thailand have been isolated by distance. Sequence diversity of PvTRAP seems to be temporally stable over one decade in Tak province based on comparison of isolates collected in 1996 (n = 36 and 2006-2007. Besides natural selection, evidences of intragenic recombination have been supported in this study that could maintain and further generate diversity in this locus. It remains to be investigated whether amino acid substitutions in PvTRAP could influence host immune responses although several predicted variant T cell epitopes drastically altered the epitope

  17. Genetic and phylogenetic analysis of a novel parvovirus isolated from chickens in Guangxi, China.

    Science.gov (United States)

    Feng, Bin; Xie, Zhixun; Deng, Xianwen; Xie, Liji; Xie, Zhiqin; Huang, Li; Fan, Qin; Luo, Sisi; Huang, Jiaoling; Zhang, Yanfang; Zeng, Tingting; Wang, Sheng; Wang, Leyi

    2016-11-01

    A previously unidentified chicken parvovirus (ChPV) strain, associated with runting-stunting syndrome (RSS), is now endemic among chickens in China. To explore the genetic diversity of ChPV strains, we determined the first complete genome sequence of a novel ChPV isolate (GX-CH-PV-7) identified in chickens in Guang Xi, China, and showed moderate genome sequence similarity to reference strains. Analysis showed that the viral genome sequence is 86.4 %-93.9 % identical to those of other ChPVs. Genetic and phylogenetic analyses showed that this newly emergent GX-CH-PV-7 is closely related to Gallus gallus enteric parvovirus isolate ChPV 798 from the USA, indicating that they may share a common ancestor. The complete DNA sequence is 4612 bp long with an A+T content of 56.66 %. We determined the first complete genome sequence of a previously unidentified ChPV strain to elucidate its origin and evolutionary status.

  18. Differential expression of parvalbumin interneurons in neonatal phencyclidine treated rats and socially isolated rats

    DEFF Research Database (Denmark)

    Kaalund, Sanne Simone; Riise, Jesper; Broberg, Brian

    2013-01-01

    of parvalbumin-positive interneurons (PV(+) interneurons). In this study we examined PV(+) expression in two rat models of cognitive dysfunction in schizophrenia, the environmental social isolation (SI) and pharmacological neonatal phencyclidine (neoPCP) models. Using a stereological method, the optical...... cells (p = 0.024) in the mPFC of neonatal phencyclidine rats. We observed no alterations in the total number of neurons, hippocampal PV(+) interneurons, parvalbumin mRNA expression or volume of the mPFC or HPC in the two models. Thus, as the total number of neurons remains unchanged following...

  19. The Xanthomonas oryzae pv. oryzae PhoPQ two-component system is required for AvrXA21 activity, hrpG expression, and virulence.

    Science.gov (United States)

    Lee, Sang-Won; Jeong, Kyu-Sik; Han, Sang-Wook; Lee, Seung-Eun; Phee, Bong-Kwan; Hahn, Tae-Ryong; Ronald, Pamela

    2008-03-01

    The rice pathogen recognition receptor, XA21, confers resistance to Xanthomonas oryzae pv. oryzae strains producing the type one system-secreted molecule, AvrXA21. X. oryzae pv. oryzae requires a regulatory two-component system (TCS) called RaxRH to regulate expression of eight rax (required for AvrXA21 activity) genes and to sense population cell density. To identify other key components in this critical regulatory circuit, we assayed proteins expressed in a raxR gene knockout strain. This survey led to the identification of the phoP gene encoding a response regulator that is up-regulated in the raxR knockout strain. Next we generated a phoP knockout strain and found it to be impaired in X. oryzae pv. oryzae virulence and no longer able to activate the response regulator HrpG (hypersensitive reaction and pathogenicity G) in response to low levels of Ca2+. The impaired virulence of the phoP knockout strain can be partially complemented by constitutive expression of hrpG, indicating that PhoP controls a key aspect of X. oryzae pv. oryzae virulence through regulation of hrpG. A gene encoding the cognate putative histidine protein kinase, phoQ, was also isolated. Growth curve analysis revealed that AvrXA21 activity is impaired in a phoQ knockout strain as reflected by enhanced growth of this strain in rice lines carrying XA21. These results suggest that the X. oryzae pv. oryzae PhoPQ TCS functions in virulence and in the production of AvrXA21 in partnership with RaxRH.

  20. Characterisation of Si-crystalline PV modules by artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Almonacid, F.; Rus, C.; Hontoria, L.; Fuentes, M.; Nofuentes, G. [Grupo Investigacion y Desarrollo en Energia Solar y Automatica, Dpto. de Ingenieria Electronica y Automatica, E.P.S. Jaen, Universidad de Jaen, Despacho B-110-AB, C vertical stroke Alfoso X El Sabio n 28, 23071 Linares (Jaen) (Spain)

    2009-04-15

    In the photovoltaic field, manufacturers provide ratings for PV modules for conditions referred to as standard test conditions (STC). However, these conditions rarely occur outdoors, so the usefulness and applicability of the indoors' characterisation in standard test conditions of PV modules are a controversial issue. Therefore, to carry out photovoltaic engineering well, a suitable characterisation of PV module electrical behaviour (V-I curves) is necessary. The IDEA Research Group from Jaen University has developed a method based on artificial neural networks (ANNs) to electrical characterisation of PV modules. An ANN has been developed which is able to generate V-I curves of Si-crystalline PV modules for any irradiance and module cell temperature. The results show that the proposed ANN introduces a good accurate prediction for Si-crystalline PV modules' performance when compared with the measured values. (author)

  1. Methods and Strategies for Overvoltage Prevention in Low Voltage Distribution Systems with PV

    DEFF Research Database (Denmark)

    Hashemi Toghroljerdi, Seyedmostafa; Østergaard, Jacob

    2016-01-01

    , the overvoltage caused by high PV penetration is described, solutions to facilitate higher PV penetration are classified, and their effectiveness, advantages, and disadvantages are illustrated. The investigated solutions include the grid reinforcement, electrical energy storage application, reactive power......The rapid development of photovoltaic (PV) systems in electrical grids brings new challenges in the control and operation of power systems. A considerable share of already installed PV units are small-scale units, usually connected to low voltage (LV) distribution systems that were not designed...... to handle a high share of PV power. This paper provides an in-depth review of methods and strategies proposed to prevent overvoltage in LV grids with PV, and discusses the effectiveness, advantages, and disadvantages of them in detail. Based on the mathematical framework presented in the paper...

  2. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  3. Determining the maximum feasible amount of photovoltaics in the European transmission grid under optimal PV utilization

    Energy Technology Data Exchange (ETDEWEB)

    Cherevatskiy, Stanislav; Troester, Eckehard [Energynautics GmbH, Langen (Germany)

    2012-07-01

    In the past few years a significant growth of the number of photovoltaic (PV) systems has been observed worldwide and particularly in Europe. Increasing maturity of this technology and growing manufacturing capacities have led to a considerable decline in prices. Looking at a future possible development of installed PV capacities in Europe, the paper at hand investigates how well the available PV energy is made use of when the installed capacity of PV reaches nearly 2000 gigawatt-peak (GWp). A methodology is presented that aims at optimal placement of PV plants taking into consideration region-specific irradiation conditions in Europe and restrictions imposed by the transmission network. Additionally, a mehtod for optimized placement and dimensioning of storage systems along with their best possible operation strategy is applied for assessment of the effect on PV utilization. (orig.)

  4. Statistical overview of findings by IR-inspections of PV-plants

    Science.gov (United States)

    Buerhop, Claudia; Pickel, Tobias; Scheuerpflug, Hans; Camus, Christian; Hauch, Jens; Brabec, Christoph J.

    2016-09-01

    First statistical evaluation of IR-inspections of PV-plants reveals that 86% of the installed PV-plants show IR-abnormalities. More than 120 PV-plants with more than 160,000 PV-modules were inspected and evaluated statistically. Main IR-abnormalities or failures in modules and string installations are analyzed, respectively. The average failure rate for PV-modules is about 8% and for module strings approximately 4%. The differentiation between the installation locations reveals that small residential installation show relatively more defective modules than large field installations. - Therefore, IR-imaging is a valuable method to give fast and reliable information about the actual quality and failure rate in inspected PV-installations.

  5. Optimal Planning Strategy for Large PV/Battery System Based on Long-Term Insolation Forecasting

    Science.gov (United States)

    Yona, Atsushi; Uchida, Kosuke; Senjyu, Tomonobu; Funabashi, Toshihisa

    Photovoltaic (PV) systems are rapidly gaining acceptance as some of the best alternative energy sources. Usually the power output of PV system fluctuates depending on weather conditions. In order to control the fluctuating power output for PV system, it requires control method of energy storage system. This paper proposes an optimization approach to determine the operational planning of power output for PV system with battery energy storage system (BESS). This approach aims to obtain more benefit for electrical power selling and to smooth the fluctuating power output for PV system. The optimization method applies genetic algorithm (GA) considering PV power output forecast error. The forecast error is based on our previous works with the insolation forecasting at one day ahead by using weather reported data, fuzzy theory and neural network(NN). The validity of the proposed method is confirmed by the computer simulations.

  6. Research Status and Solution for Photovoltaic/thermal (PV/T) Solar System%光伏/热(PV/T)太阳能系统的研究现状及解决方案

    Institute of Scientific and Technical Information of China (English)

    何永泰; 肖丽仙; 刘晋豪; 李雷

    2014-01-01

    The research status of the photovoltaic/thermal ( PV/T) solar system is introduced in the paper. The cause of poor practicability for the PV/T solar system is analyzed. In order to improver the practicability of the PV/T solar system, the solutions ( integrated condenser in PV/T solar system, opti-mized the structure of PV/T collector, balance of the conversion efficiency and the operation temperature, perfection evaluation method) are proposed based on the structure and theory of the PV/T collector.%本文介绍了PV/T太阳能系统的研究现状,分析了导致PV/T太阳能系统实用性差的原因。根据PV/T太阳能系统的结构特点及其相关理论,提出聚光技术与PV/T太阳能系统集成、 PV/T集热器结构优化、 PV/T太阳能系统转换效率与工作温度之间的平衡及完善PV/T太阳能特性评价体系的解决方案。实验证明方案有利于提高PV/T太阳能系统的实用性。

  7. Incremental Conductance MPPT Algorithm for PV System Implemented Using DC-DC Buck and Boost Converter

    OpenAIRE

    2014-01-01

    The two basic topologies of switch mode DC-DC converters (Buck and Boost) are analyzed with a view of their use in PV (photovoltaic) systems, as the photovoltaic generator exhibits non-linear characteristics due to the change in environmental condition and load variation. As the efficiency of PV panels is low it becomes mandatory to extract maximum power from the PV panel at a given period of time. Several MPPT algorithms with different types of converters are being proposed f...

  8. Distributed Solar PV for Electricity System Resiliency: Policy and Regulatory Considerations (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    Distributed Solar PV systems have the potential of increasing the grid's resiliency to unforeseen events, such as extreme weather events and attacks. This paper presents the role that distributed PV can play in electric grid resiliency, introduces basic system design requirements and options, and discusses the regulatory and policy options for supporting the use of distributed PV for the purpose of increased electricity resiliency.

  9. Grid Integration of PV Power based on PHIL testing using different Interface Algorithms

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso;

    2013-01-01

    Photovoltaic (PV) power among all renewable energies had the most accelerated growth rate in terms of installed capacity in recent years. Transmission System Operators (TSOs) changed their perspective about PV power and started to include it into their planning and operation, imposing PV systems...... and supply of ancillary services, first the grid has to be simulated using PHIL, but in order to achieve it, different interface algorithms (IA) had to be evaluated in terms of system stability and signal accuracy....

  10. Final Technical Report: Advanced Measurement and Analysis of PV Derate Factors.

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce Hardison [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burton, Patrick D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hansen, Clifford [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-12-01

    The Advanced Measurement and Analysis of PV Derate Factors project focuses on improving the accuracy and reducing the uncertainty of PV performance model predictions by addressing a common element of all PV performance models referred to as “derates”. Widespread use of “rules of thumb”, combined with significant uncertainty regarding appropriate values for these factors contribute to uncertainty in projected energy production.

  11. Regulatory islanding parameters in battery based solar PV for electricity system resiliency

    OpenAIRE

    Alsayyed, Nidal; Zhu, Weihang

    2016-01-01

    Distributed battery based solar power photovoltaic (PV) systems have the potential to supply electricity during grid outages resulting from extreme weather or other emergency situations. As such, distributed PV can significantly increase the resiliency of the electricity system. In order to take advantage of this capability, however, the PV systems must be designed with regulatory parameters in mind and combined with other technologies, such as smart energy storage and auxiliary generation. S...

  12. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    Energy Technology Data Exchange (ETDEWEB)

    O' Shaughnessy, Eric; Margolis, Robert

    2017-05-18

    We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

  13. Using Residential Solar PV Quote Data to Analyze the Relationship Between Installer Pricing and Firm Size

    Energy Technology Data Exchange (ETDEWEB)

    O' Shaughnessy, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-19

    We use residential solar photovoltaic (PV) quote data to study the role of firm size in PV installer pricing. We find that large installers (those that installed more than 1,000 PV systems in any year from 2013 to 2015) quote higher prices for customer-owned systems, on average, than do other installers. The results suggest that low prices are not the primary value proposition of large installers.

  14. Optimal Capacity Allocation of Large-Scale Wind-PV-Battery Units

    OpenAIRE

    Kehe Wu; Huan Zhou; Jizhen Liu

    2014-01-01

    An optimal capacity allocation of large-scale wind-photovoltaic- (PV-) battery units was proposed. First, an output power model was established according to meteorological conditions. Then, a wind-PV-battery unit was connected to the power grid as a power-generation unit with a rated capacity under a fixed coordinated operation strategy. Second, the utilization rate of renewable energy sources and maximum wind-PV complementation was considered and the objective function of full life cycle-net...

  15. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    PVs. In order to increase PV penetration level further, new voltage support control functions for individual inverters are required. This paper investigates distributed reactive power regulation and active power curtailment strategies regarding the development of PV connection capacity by evaluation......Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections from...

  16. Life cycle assessment study of solar PV systems: An example of a 2.7kW{sub p} distributed solar PV system in Singapore

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, R.; Leong, K.C.; Osman, R.; Ho, H.K. [School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Tso, C.P. [Faculty of Engineering and Technology, Multimedia University, Jalan Ayer Keroh Lama, 75450 Melaka (Malaysia)

    2006-05-15

    In life cycle assessment (LCA) of solar PV systems, energy pay back time (EPBT) is the commonly used indicator to justify its primary energy use. However, EPBT is a function of competing energy sources with which electricity from solar PV is compared, and amount of electricity generated from the solar PV system which varies with local irradiation and ambient conditions. Therefore, it is more appropriate to use site-specific EPBT for major decision-making in power generation planning. LCA and life cycle cost analysis are performed for a distributed 2.7kW{sub p} grid-connected mono-crystalline solar PV system operating in Singapore. This paper presents various EPBT analyses of the solar PV system with reference to a fuel oil-fired steam turbine and their greenhouse gas (GHG) emissions and costs are also compared. The study reveals that GHG emission from electricity generation from the solar PV system is less than one-fourth that from an oil-fired steam turbine plant and one-half that from a gas-fired combined cycle plant. However, the cost of electricity is about five to seven times higher than that from the oil or gas fired power plant. The environmental uncertainties of the solar PV system are also critically reviewed and presented. (author)

  17. Calculation Method and Analysis for the Annual Power Generation of PV Façades in China

    Institute of Scientific and Technical Information of China (English)

    Shen Xu; ZhongMing Hu; Jian Kang; Wei Liao; Jing Huang

    2014-01-01

    The application of PV façades emerges greatly in recent years and however its calculation methods and analysis remains insufficient under the weather conditions of China. In such demand, this paper investigates PV façade in terms of PV electricity generation in different arrangements and weather conditions of four major cities in China. The calculation models for PV façade are developed and validated by comparing the results with the measured data from the field experiments. A parametric study is carried out to provide a reference for the optimal design of the PV façades. The results show that with various cities, building orientations, building forms, materials and arrangements of PV modules, there is a distinct difference in the electrical output energy of PV façades. Weather conditions play a very important role in terms of PV generation performance of PV façades.

  18. Distribution System Augmented by DC Links for Increasing the Hosting Capacity of PV Generation

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Demirok, Erhan; Teodorescu, Remus

    2012-01-01

    This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further, they are cha......This paper presents a concept of enhancing the photovoltaic (PV) power generation hosting capacity of distribution networks. Distribution network serving electrical energy to farm settlements was selected as an example for their large roof area available for PV installation. Further...

  19. Comparative Analysis and Considerations for PV Interconnection Standards in the United States and China

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-01-01

    The main objectives of this report are to evaluate China's photovoltaic (PV) interconnection standards and the U.S. counterparts and to propose recommendations for future revisions to these standards. This report references the 2013 report Comparative Study of Standards for Grid-Connected PV System in China, the U.S. and European Countries, which compares U.S., European, and China's PV grid interconnection standards; reviews various metrics for the characterization of distribution network with PV; and suggests modifications to China's PV interconnection standards and requirements. The recommendations are accompanied by assessments of four high-penetration PV grid interconnection cases in the United States to illustrate solutions implemented to resolve issues encountered at different sites. PV penetration in China and in the United States has significantly increased during the past several years, presenting comparable challenges depending on the conditions of the grid at the point of interconnection; solutions are generally unique to each interconnected PV installation or PV plant.

  20. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Roger R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Klise, Geoffrey Taylor [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Integration; Balfour, John R. [High Performance PV, Phoenix, AZ (United States)

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  1. Dynamic response evaluation of sensorless MPPT method for hybrid PV-DFIG wind turbine system

    Directory of Open Access Journals (Sweden)

    Danvu Nguyen

    2016-01-01

    Full Text Available This research proposes a sensorless Maximum Power Point Tracking (MPPT method for a hybrid Photovoltaic-Wind system, which consists of Photovoltaic (PV system and Doubly-Fed Induction Generator (DFIG Wind Turbine. In the hybrid system, the DC/DC converter output of the PV system is directly connected to the DC-link of DFIG’s back-to-back converter. Therefore, the PV inverter and its associated circuit can be removed in this structure. Typically, the PV power is monitored by using PV current sensor and PV voltage sensor for MPPT. In this paper, the powers of converters on grid side and rotor side of DFIG are used to estimate the PV power without the PV current sensor. That can efficiently reduce the cost of the hybrid system. The detailed analysis of the sensorless MPPT method, which includes derived equations and operation response, is also presented in this paper. In addition, an overview of PV-DFIG research in literature is stated to supply comprehensive knowledge of related research.

  2. Intelligent control of PV system on the basis of the fuzzy recurrent neuronet*

    Science.gov (United States)

    Engel, E. A.; Kovalev, I. V.; Engel, N. E.

    2016-04-01

    This paper presents the fuzzy recurrent neuronet for PV system’s control. Based on the PV system’s state, the fuzzy recurrent neural net tracks the maximum power point under random perturbations. The validity and advantages of the proposed intelligent control of PV system are demonstrated by numerical simulations. The simulation results show that the proposed intelligent control of PV system achieves real-time control speed and competitive performance, as compared to a classical control scheme on the basis of the perturbation & observation algorithm.

  3. Determining the Effects of Environment and Atmospheric Parameters on PV Field Performance

    Energy Technology Data Exchange (ETDEWEB)

    Micheli, Leonardo; Muller, Matthew; Kurtz, Sarah

    2016-11-21

    The performance losses due to soiling occurring on any photovoltaic (PV) device are caused by a complex mechanism that involves numerous factors and their interactions. For this reason, the present work analyzes the outputs of reference PV cells installed in various locations, with the aim of contributing to the identification of the most important factors influencing the accumulation of dust on a PV surface. Parameters such as the air-quality indexes, the recurrence and the amount of rainfall and the climate zone are investigated and related to the soiling losses of the PV device.

  4. Modeling of PV Systems Based on Inflection Points Technique Considering Reverse Mode

    Directory of Open Access Journals (Sweden)

    Bonie J. Restrepo-Cuestas

    2013-11-01

    Full Text Available This paper proposes a methodology for photovoltaic (PV systems modeling, considering their behavior in both direct and reverse operating mode and considering mismatching conditions. The proposed methodology is based on the inflection points technique with a linear approximation to model the bypass diode and a simplified PV model. The proposed mathematical model allows to evaluate the energetic performance of a PV system, exhibiting short simulation times in large PV systems. In addition, this methodology allows to estimate the condition of the modules affected by the partial shading since it is possible to know the power dissipated due to its operation at the second quadrant.

  5. Pyranometers and Reference Cells: Part 2: What Makes the Most Sense for PV Power Plants?; Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Meydbray, J.; Riley, E.; Dunn, L.; Emery, K.; Kurtz, S.

    2012-10-01

    As described in Part 1 of this two-part series, thermopile pyranometers and photovoltaic (PV) reference cells can both be used to measure irradiance; however, there are subtle differences between the data that are obtained. This two-part article explores some implications of uncertainty and subtleties of accurately measuring PV efficiency in the field. Part 2 of the series shows how reference cells can be used to more confidently predict PV performance, but how this could best be accomplished if historic irradiance data could be available in PV-technology-specific formats.

  6. EFFECT OF REFLECTOR APPLICATION ON PV PANEL PERFORMANCE UNDER EGYPTIAN CONDITIONS

    OpenAIRE

    Mamdouh Abbas HELMY; E. M. KHALIFA; A. M. OKSHA; A. W. ELHADDAD

    2014-01-01

    The proposed approach in the present study is to employ a mirror augmented PV solar panel to track the sun and reflect rays on to the PV panel. Its performance was compared with same PV module without reflector under the same environmental conditions. The mirror augmented solar PV panel tracked sun from East to West along the daytime in Winter 2011 with tilt angle0.523 rad (30 deg) for panel and 0.122 rad (7deg) for mirror which are estimated by experiment. The average energy output values of...

  7. Delta Power Control Strategy for Multi-String Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    With a still increasing penetration level of grid-connected PV systems, more advanced active power control functionalities have been introduced in certain grid regulations. A delta power constraint, where a portion of the active power from the PV panels is reserved during operation, is required...... for the entire PV system is achieved. Simulations and experiments have been performed on a 3-kW single-phase grid-connected PV system. The results have confirmed the effectiveness of the delta power control strategy, where the power reserve according to the delta power constraint is achieved under several...

  8. Optimization of SiC-based H5 and Conergy-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The transformerless DC/AC inverters are critical components in the rapidly growing market of grid-connected Photovoltaic (PV) applications. Also, the SiC-based power semiconductors are capable to operate reliably at high operating temperature and switches frequency levels. In this paper, a new...... profitability of the PV system....... design technique is presented for optimizing the switching frequency and structure of the LCL-type output filter in transformerless H5 and Conergy-NPC PV inverters, which employ SiC-type power devices. The design optimization results demonstrate that the optimized SiC-based PV inverters are more...

  9. How to Estimate Demand Charge Savings from PV on Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Pieter J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Bird, Lori A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-28

    Rooftop photovoltaic (PV) systems are compensated through retail electricity tariffs - and for commercial and industrial customers, these are typically comprised of three components: a fixed monthly charge, energy charges, and demand charges. Of these, PV's ability to reduce demand charges has traditionally been the most difficult to estimate. In this fact sheet we explain the basics of demand charges, and provide a new method that a potential customer or PV developer can use to estimate a range of potential demand charge savings for a proposed PV system. These savings can then be added to other project cash flows, in assessing the project's financial performance.

  10. Development and implementation of a PV performance monitoring system based on inverter measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Gavriluta, Anamaria Florina; Sera, Dezso

    2016-01-01

    applications the cost of the performance monitoring hardware and implementation is still high. Therefore, we present the practical development and implementation of a low-cost PV performance monitoring system for residential and commercial PV applications, based on the inverter’s own monitoring......Performance monitoring and fault detection systems are becoming more common in large photovoltaic (PV) plants as they can contribute to decreasing operation and maintenance costs, as well as for maximizing plant yield and lifetime. However, in case of residential and smaller commercial PV system...

  11. EFFECT OF REFLECTOR APPLICATION ON PV PANEL PERFORMANCE UNDER EGYPTIAN CONDITIONS

    OpenAIRE

    Mamdouh Abbas HELMY; E. M. KHALIFA; A. M. OKSHA; A. W. ELHADDAD

    2014-01-01

    The proposed approach in the present study is to employ a mirror augmented PV solar panel to track the sun and reflect rays on to the PV panel. Its performance was compared with same PV module without reflector under the same environmental conditions. The mirror augmented solar PV panel tracked sun from East to West along the daytime in Winter 2011 with tilt angle0.523 rad (30 deg) for panel and 0.122 rad (7deg) for mirror which are estimated by experiment. The average energy output values of...

  12. Power Electronic System for Multi-MW PV sites

    DEFF Research Database (Denmark)

    Paasch, Kasper

    for solar inverters is under a severe pressure regarding cost reduction. The main topic of this thesis is the investigation of the potential advantage of applying string inverters with multiple Maximum-Power-Point-trackers (MPPT) in large PV plants compared to the use of one large central inverter with one.......4%. A portable IV-scanning instrument for the fast long term characterization of solar panels was developed as part of the project. Each second a sweep of the IV-characteristics of a solar panel is performed and the result stored for later analysis. The instrument is based on an active load, is optimized...

  13. Weather modeling and forecasting of PV systems operation

    CERN Document Server

    Paulescu, Marius; Gravila, Paul; Badescu, Viorel

    2012-01-01

    In the past decade, there has been a substantial increase of grid-feeding photovoltaic applications, thus raising the importance of solar electricity in the energy mix. This trend is expected to continue and may even increase. Apart from the high initial investment cost, the fluctuating nature of the solar resource raises particular insertion problems in electrical networks. Proper grid managing demands short- and long-time forecasting of solar power plant output. Weather modeling and forecasting of PV systems operation is focused on this issue. Models for predicting the state of the sky, nowc

  14. Spectrally-Selective Photonic Structures for PV Applications

    Directory of Open Access Journals (Sweden)

    Benedikt Bläsi

    2010-01-01

    Full Text Available We review several examples of how spectrally-selective photonic structures may be used to improve solar cell systems. Firstly, we introduce different spectrally-selective structures that are based on interference effects. Examples shown include Rugate filter, edge filter and 3D photonic crystals such as artificial opals. In the second part, we discuss several examples of photovoltaic (PV concepts that utilize spectral selectivity such as fluorescence collectors, upconversion systems, spectrum splitting concepts and the intermediate reflector concept. The potential of spectrally selective filters in the context of solar cells is discussed.

  15. Analysis of Irradiance Models for Bifacial PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Clifford W.; Stein, Joshua S.; Deline, Chris; MacAlpine, Sara; Marion, Bill; Asgharzadeh, Amir; Toor, Fatima

    2016-11-21

    We describe and compare two methods for modeling irradiance on the back surface of rack-mounted bifacial PV modules: view factor models and ray-tracing simulations. For each method we formulate one or more models and compare each model with irradiance measurements and short circuit current for a bifacial module mounted a fixed tilt rack with three other similarly sized modules. Our analysis illustrates the computational requirements of the different methods and provides insight into their practical applications. We find a level of consistency among the models which indicates that consistent models may be obtained by parameter calibrations.

  16. Silicon shortage: supply constraints limit PV growth until 2008

    Energy Technology Data Exchange (ETDEWEB)

    Flynn, H.; Bradford, T. [Prometheus Inst. (United States)

    2006-10-01

    It is argued that a shortage of refined (polycystalline) silicon will curtail the expansion of the solar photovoltaics industry until about 2008. At present, 94% of PV cells produced worldwide use refined silicon. The problem has arisen because the traditional source, scrap silicon from the electronics industry, is no longer available in sufficient quantities - demand has outstripped supply. Although plans are in place to double the present supply of silicon over the next four years, doubts are expressed over the likelihood of this happening. Currently, there are only seven big companies producing the silicon - production figures for these companies are given. (author)

  17. Testing Interconnections using Conductive Adhesives for Application in PV Modules

    Energy Technology Data Exchange (ETDEWEB)

    Broek, K.M.; De Jong, P.C.; Kloos, M.J.H. [ECN Solar Energy, Petten (Netherlands); Van den Nieuwenhof, M.A.C.J.; Bots, T.L.; Meuwissen, M.H.H.; Steijvers, H.L.A.H. [TNO Science and Industry, Eindhoven (Netherlands)

    2006-09-15

    In current module production the electrical interconnections are soldered to the solar cells. For current modules with thin cells and new module concepts with back contact cells, the replacement of solder by conductive adhesives can be advantageous. However, the current IEC tests were developed for soldered interconnections, which have other failure mechanisms. Therefore, three additional tests have been developed for the testing of conductive adhesives to be used in solar modules. In combination with computer simulation techniques developed in the same project, the tests will contribute to a better understanding of failure mechanisms of PV modules with conductive adhesives.

  18. Typing of Panton-Valentine Leukocidin-encoding Phages and lukSF-PV Gene Sequence Variation in Staphylococcus aureus from China

    Directory of Open Access Journals (Sweden)

    Huanqiang Zhao

    2016-08-01

    Full Text Available Panton-Valentine leucocidin (PVL, encoded by lukSF-PV genes, a bi-component and pore-forming toxin, is carried by different staphylococcal bacteriophages. The prevalence of PVL in Staphylococcus aureus (S. aureus have been reported around the globe. However, the data on PVL-encoding phage types, lukSF-PV gene variation and chromosomal phage insertion sites for PVL-positive S. aureus are limited, especially in China. In order to obtain a more complete understanding of the molecular epidemiology of PVL-positive S. aureus, an integrated and modified PCR-based scheme was applied to detect the PVL-encoding phage types. Phage insertion locus and the lukSF-PV variant were determined by PCR and sequencing. Meanwhile, the genetic background was characterized by staphylococcal cassette chromosome mec (SCCmec typing, staphylococcal protein A (spa gene polymorphisms typing, pulsed-field gel electrophoresis (PFGE typing, accessory gene regulator (agr locus typing and multilocus sequence typing (MLST. Seventy eight (78/1175, 6.6% isolates possessed the lukSF-PV genes and 59.0% (46/78 of PVL-positive strains belonged to CC59 lineage. Eight known different PVL-encoding phage types were detected, and Φ7247PVL/ΦST5967PVL (n=13 and ΦPVL (n=12 were the most prevalent among them. While 25 (25/78, 32.1% isolates, belonging to ST30 and ST59 clones, were unable to be typed by the modified PCR-based scheme. Single nucleotide polymorphisms (SNPs were identified at five locations in the lukSF-PV genes, two of which were non-synonymous. Maximum-likelihood tree analysis of attachment sites sequences detected six SNP profiles for attR and eight for attL, respectively. In conclusion, the PVL-positive S. aureus mainly harbored Φ7247PVL/ΦST5967PVL and ΦPVL in the regions studied. lukSF-PV gene sequences, PVL-encoding phages and phage insertion locus generally varied with lineages. Moreover, PVL-positive clones that have emerged worldwide likely carry distinct phages.

  19. Typing of Panton-Valentine Leukocidin-Encoding Phages and lukSF-PV Gene Sequence Variation in Staphylococcus aureus from China.

    Science.gov (United States)

    Zhao, Huanqiang; Hu, Fupin; Jin, Shu; Xu, Xiaogang; Zou, Yuhan; Ding, Baixing; He, Chunyan; Gong, Fang; Liu, Qingzhong

    2016-01-01

    Panton-Valentine leukocidin (PVL, encoded by lukSF-PV genes), a bi-component and pore-forming toxin, is carried by different staphylococcal bacteriophages. The prevalence of PVL in Staphylococcus aureus has been reported around the globe. However, the data on PVL-encoding phage types, lukSF-PV gene variation and chromosomal phage insertion sites for PVL-positive S. aureus are limited, especially in China. In order to obtain a more complete understanding of the molecular epidemiology of PVL-positive S. aureus, an integrated and modified PCR-based scheme was applied to detect the PVL-encoding phage types. Phage insertion locus and the lukSF-PV variant were determined by PCR and sequencing. Meanwhile, the genetic background was characterized by staphylococcal cassette chromosome mec (SCCmec) typing, staphylococcal protein A (spa) gene polymorphisms typing, pulsed-field gel electrophoresis (PFGE) typing, accessory gene regulator (agr) locus typing and multilocus sequence typing (MLST). Seventy eight (78/1175, 6.6%) isolates possessed the lukSF-PV genes and 59.0% (46/78) of PVL-positive strains belonged to CC59 lineage. Eight known different PVL-encoding phage types were detected, and Φ7247PVL/ΦST5967PVL (n = 13) and ΦPVL (n = 12) were the most prevalent among them. While 25 (25/78, 32.1%) isolates, belonging to ST30, and ST59 clones, were unable to be typed by the modified PCR-based scheme. Single nucleotide polymorphisms (SNPs) were identified at five locations in the lukSF-PV genes, two of which were non-synonymous. Maximum-likelihood tree analysis of attachment sites sequences detected six SNP profiles for attR and eight for attL, respectively. In conclusion, the PVL-positive S. aureus mainly harbored Φ7247PVL/ΦST5967PVL and ΦPVL in the regions studied. lukSF-PV gene sequences, PVL-encoding phages, and phage insertion locus generally varied with lineages. Moreover, PVL-positive clones that have emerged worldwide likely carry distinct phages.

  20. Biophysical and molecular comparison of sodium current in cells isolated from canine atria and pulmonary vein.

    Science.gov (United States)

    Barajas-Martinez, Hector; Goodrow, Robert J; Hu, Dan; Patel, Payal; Desai, Mayurika; Panama, Brian K; Treat, Jacqueline A; Aistrup, Gary L; Cordeiro, Jonathan M

    2017-02-27

    The collar of the pulmonary vein (PV) is the focal point for the initiation of atrial arrhythmias, but the mechanisms underlying how PV cells differ from neighboring left atrial tissue are unclear. We examined the biophysical and molecular properties of INa in cells isolated from the canine pulmonary sleeve and compared the properties to left atrial tissue. PV and left atrial myocytes were isolated and patch clamp techniques were used to record INa. Action potential recordings from either tissue type were made using high-resistance electrodes. mRNA was determined using quantitative RT-PCR and proteins were determined by Western blot. Analysis of the action potential characteristics showed that PV tissue had a lower Vmax compared with left atrial tissue. Fast INa showed that current density was slightly lower in PV cells compared with LA cells (-96 ± 18.7 pA/pF vs. -120 ± 6.7 pA/pF, respectively, p < 0.05). The recovery from inactivation of INa in PV cells was slightly slower but no marked difference in steady-state inactivation was noted. Analysis of late INa during a 225-ms pulse showed that late INa was significantly smaller in PV cells compared to LA cells at all measured time points into the pulse. These results suggest PV cells have lower density of both peak and late INa. Molecular analysis of Nav1.5 and the four beta subunits showed lower levels of Nav1.5 as well as Navβ1 subunits, confirming the biophysical findings. These data show that a lower density of INa may lead to depression of excitability and predispose the PV collar to re-entrant circuits under pathophysiological conditions.