WorldWideScience

Sample records for pumping equipment ahorro

  1. Energy saving in agricultural pumping equipment; Ahorro de energia en equipos de bombeo agricola

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R Aracely [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1994-12-31

    This paper analyses the current state of the pumping equipment for agricultural irrigation in Mexico. Because of being of the vertical centrifugal turbine type pumps, the most commonly utilized for this service, the study has been focussed into this equipment, obtaining efficiency and consumption scenarios, as well as the potential energy saving existing in this sector. [Espanol] En el presente articulo se analiza el estado actual de los equipos de bombeo para riego agricola en Mexico, al ser las bombas centrifugas verticales tipo turbina, las mas comunmente utilizadas para este servicio, el estudio ha sido enfocado a estos equipos, obteniendose los escenarios de eficiencias y consumos, asi como, el potencial de ahorro energetico existente en este sector.

  2. Energy saving in agricultural pumping equipment; Ahorro de energia en equipos de bombeo agricola

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R. Aracely [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1993-12-31

    This paper analyses the current state of the pumping equipment for agricultural irrigation in Mexico. Because of being of the vertical centrifugal turbine type pumps, the most commonly utilized for this service, the study has been focussed into this equipment, obtaining efficiency and consumption scenarios, as well as the potential energy saving existing in this sector. [Espanol] En el presente articulo se analiza el estado actual de los equipos de bombeo para riego agricola en Mexico, al ser las bombas centrifugas verticales tipo turbina, las mas comunmente utilizadas para este servicio, el estudio ha sido enfocado a estos equipos, obteniendose los escenarios de eficiencias y consumos, asi como, el potencial de ahorro energetico existente en este sector.

  3. Mono pump equipment evaluation report

    International Nuclear Information System (INIS)

    1992-01-01

    A mobile pump has been designed, developed, and tested as part of an effort to increase oil spill response time, improve oil/water recovery efficiency and reduce cleanup and reclamation costs. The pump is mounted on an engine powered track carrier, and can be detached from the carrier and skidded into remote spill sites or transported by helicopter. The pump can safely recover highly volatile flammable substances such as condensate and gasoline, as well as heavy crude oil up to 5000 centipoise viscosity. It can pump up to 30 gal/min at zero head, and up to 1000 feet in a vertical direction. 13 figs

  4. Proposal for energy saving in air conditioning equipment; Propuesta para ahorro energetico en acondicionadores de aire

    Energy Technology Data Exchange (ETDEWEB)

    Solis Recendez, Daniel H [Division de Ingenieria Electrica, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-10-15

    In the last decades, the air conditioning systems have become a crucial part in the search from comfort in extreme climates. Nevertheless, they have also become one of the greatest energy consumers. In this article it is proposed that the final conditions that the air conditioning equipment looks for not to be fixed, but variable in respect to a certain comfort zone. This zone is a variation of the used one in the bio-climatic chart of Olgyay that considers the rapidity whereupon the reached conditions tend to leave the comfort zone. It is analyzed how to choose the point on the zone that costs less energy in arriving to it. [Spanish] En las ultimas decadas, los sistemas de aire acondicionado se han vuelto una parte crucial en la busqueda de confort en climas extremosos. Sin embargo, tambien se han vuelto de los mayores consumidores de energia. En este articulo se propone que las condiciones finales que busquen lograr los acondicionadores no sean fijas, si no variables respecto a una determinada zona de confort. Dicha zona es una variacion de la utilizada en la carta bioclimatica de Olgyay, que considera la rapidez con que las condiciones alcanzadas tienden a abandonar la zona de confort. Se discute como elegir el punto sobre la zona que cueste menos energia en llegara el.

  5. Energy saving in the pumping of drinking water, Municipality of San Felipe, Guanajuato; Ahorro de energia electrica en bombeo de agua potable, en el municipio de San Felipe, Gto.

    Energy Technology Data Exchange (ETDEWEB)

    Gamiz Sanchez, Lorenzo [Applied Technology Center de Mexico, S.A. de C.V. (Mexico)

    2006-01-15

    This paper shows the results attained in energy saving through a project of potable water pumping, which took an investment of $433,043.00 and an internal rate of return of 126%. This project puts into evidence that it is possible to reduce between 15 and 30% of the total invoicing for energy consumption in potable water pumping if an equipment of poor efficiency is replaced by another of high efficiency. The project was requested by the Guanajuato's State Water Comision and the Municipal Bureau of Sewage and Potable Water, with the double intention of reducing the energy consumption along with the corresponding invoicing and incrementing the output of the wells in order to improve the potable water supply. In the site two high efficiency submersible motor-pumps were installed previously to the energy diagnosis that triggered profitable operation results and a convenient invoicing. [Spanish] Se documentan los resultados obtenidos en un proyecto de ahorro de energia en el bombeo de agua potable realizado con una inversion de $433,043.00 y con una tasa interna de retorno de 126%. Este proyecto pone en evidencia que es posible reducir entre el 15 y 30% de la facturacion total por consumo de energia electrica en el bombeo de agua potable si se sustituye un equipo poco eficiente por otro de alta eficiencia. El proyecto fue solicitado por la Comision Estatal del Agua de Guanajuato y la Junta Municipal de Agua Potable y Alcantarillado del municipio, con un doble proposito, reducir el consumo de energia junto con la facturacion correspondiente e incrementar la capacidad de produccion de los pozos con la intencion de mejorar el abasto de agua potable. En el lugar se instalaron dos motobombas sumergibles de alta eficiencia previo diagnostico energetico que desencadenaron rentables resultados operativos y de facturacion.

  6. Energy saving in hotels by means of heat pumps application; Ahorro de energia en hoteles mediante la aplicacion de bombas de calor

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes R, Hernando; Ambriz G, Juan Jose [Universidad Autonoma Metropolitana, Unidad Iztapalapa (Mexico)

    2005-07-15

    The thermal energy is presented as an alternate saving technology for utilities by means of the acute implementation of heat pumps. The objective is to demonstrate the technical and economical feasibility of the application of commercial heat pumps to installations where the handling of opposite temperatures for the conditioning of a space and/or of a fluid is required. In this article it is described the functioning of a heat pump, its different operation principles or types as well as the large diversity of applications they can have in industry, utilities and residential buildings. As an application example the substitution of an electric boiler by a heat pump is presented in a hotel installation and its differences in performance regarding the environmental conditioning of a nearby area and the heating of swimming pool water are analyzed. [Spanish] Se presenta la energia termica como una tecnologia de ahorro alterna para empresas de servicios valiendose de la implementacion agudizada de bombas de calor. El objetivo es demostrar la factibilidad tecnica y economica de la aplicacion de bombas de calor comerciales a instalaciones donde se requiere la manipulacion de temperaturas opuestas para el acondicionamiento de un espacio y/o un fluido. Se describe el funcionamiento de una bomba de calor, sus diferentes principios de operacion o tipos, asi como la gran diversidad de aplicaciones que pueden tener en la industria, empresas de servicios y edificios residenciales. Como ejemplo de aplicacion se presenta la sustitucion de una caldera electrica por una bomba de calor en una instalacion hotelera y sus diferencias de rendimiento en el calentamiento de agua de alberca y el acondicionamiento ambiental de un area cercana.

  7. Measurements on a PV solar pump equipped with a piston pump with a matching valve

    NARCIS (Netherlands)

    Smulders, P.T.; Ten Thije O.G. Boonkkamp, J.; Borg, van der N.J.C.M.; Beek, van M.

    1997-01-01

    The work on a simple high efficient solar pump equipped with a piston pump with a matching valve, reported at the Solar World Congress in Budapest, has been continued. Quasi-static and dynamic models of the solar pump have been derived with which the operation of the system is simulated. A test rig

  8. Evaluation of energy saving in pilot projects of window type air conditioning equipment in the domestic sector; Evaluacion del ahorro de energia en proyectos pilotos en equipos de aire acondicionado tipo ventana en el sector domestico

    Energy Technology Data Exchange (ETDEWEB)

    Duran Ramirez, Ricardo [Comision Nacional para el Ahorro de Energia, Mexico, D.F. (Mexico)

    2001-07-01

    The present work shows the energy saving when replacing low efficiency window type air conditioning equipment, for higher efficiency equipment, as well as the necessary parameters to identify the results obtained by the pilot projects of substitution of conventional equipment for other more efficient in the domestic sector. [Spanish] El presente trabajo muestra los ahorros de energia al sustituir equipos de aire acondicionado tipo ventana de baja eficiencia, por equipos de mayor eficiencia, asi como los parametros necesarios para identificar los resultados obtenidos, por los proyectos pilotos de sustitucion de equipos convencionales por otros mas eficientes en el sector domestico.

  9. Failure Mode and Effect Analysis of Subsea Multiphase Pump Equipment

    Directory of Open Access Journals (Sweden)

    Oluwatoyin Shobowale Kafayat

    2014-07-01

    Full Text Available Finding oil and gas reserves in deep/harsh environment with challenging reservoir and field conditions, subsea multiphase pumping benefits has found its way to provide solutions to these issues. Challenges such as failure issues that are still surging the industry and with the current practice of information hiding, this issues becomes even more difficult to tackle. Although, there are some joint industry projects which are only accessible to its members, still there is a need to have a clear understanding of these equipment groups so as to know which issues to focus attention on. A failure mode and effect analysis (FMEA is a potential first aid in understanding this equipment groups. A survey questionnaire/interview was conducted with the oil and gas operating company and equipment manufacturer based on the literature review. The results indicates that these equipment’s group are similar with its onshore counterpart, but the difference is the robustness built into the equipment internal subsystems for subsea applications. The results from the manufacturer perspectives indicates that Helico-axial multiphase pump have a mean time to failure of more than 10 years, twin-screw and electrical submersible pumps are still struggling with a mean time to failure of less than 5 years.

  10. Energy saving in the auxiliaries consumption for circulation water pumps optimizing the thermal regime; Ahorro en el consumo de auxiliares por bombas de agua de circulacion optimando el regimen termico

    Energy Technology Data Exchange (ETDEWEB)

    Orozco Martinez, Roni [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1999-12-31

    A methodology is proposed that should be followed in any thermal electric power plant to determine the load value at which a unit requires a second circulation water pump without affecting the thermal regime and avoiding an excessive auxiliaries consumption in partial loads. In applying this method the power plant would have an energy saving equivalent to the auxiliaries consumption during an hour, when the unit as operating at full load. [Espanol] Se propone una metodologia que debe seguirse en cualquier central termoelectrica para determinar el valor de la carga en la cual una unidad requiere de la segunda bomba de agua de circulacion sin afectar el regimen termico y evitadose un excesivo consumo de auxiliares en cargas parciales. Al aplicar este metodo la central tendria un ahorro de energia equivalente al consumo de auxiliares durante una hora cuando la unidad esta generando su maxima carga.

  11. Energy saving in the auxiliaries consumption for circulation water pumps optimizing the thermal regime; Ahorro en el consumo de auxiliares por bombas de agua de circulacion optimando el regimen termico

    Energy Technology Data Exchange (ETDEWEB)

    Orozco Martinez, Roni [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    A methodology is proposed that should be followed in any thermal electric power plant to determine the load value at which a unit requires a second circulation water pump without affecting the thermal regime and avoiding an excessive auxiliaries consumption in partial loads. In applying this method the power plant would have an energy saving equivalent to the auxiliaries consumption during an hour, when the unit as operating at full load. [Espanol] Se propone una metodologia que debe seguirse en cualquier central termoelectrica para determinar el valor de la carga en la cual una unidad requiere de la segunda bomba de agua de circulacion sin afectar el regimen termico y evitadose un excesivo consumo de auxiliares en cargas parciales. Al aplicar este metodo la central tendria un ahorro de energia equivalente al consumo de auxiliares durante una hora cuando la unidad esta generando su maxima carga.

  12. Energy saving by means of air conditioning equipment replacement and the household application of thermal insulation; Ahorro de energia electrica por reemplazo de equipos de aire acondicionado y aplicacion de aislamiento termico en viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de la Energia (Mexico)

    2005-07-15

    An extension study of the Financing Program for Energy Saving looked for the evaluation of the electric energy saving potential obtained by the replacement of air conditioning equipment and the application of thermal insulation in 30 houses of two Mexican cities with warmth climate. In a joint effort with Comision Federal de Electricidad the consumption files of the users were analyzed and field measurements of electric demand and of refrigeration were made. As a following step the change of the refrigeration necessities derived from the application of thermal insulation were evaluated as well as the energy efficiency improvement obtained by the substitution of the air conditioning equipment and the favorable results obtained by the implementation of both measures - thermal insulation and change of air conditioning equipment in a joint form. This way, as a conclusion, the optimum sequence of application of these measures is revealed. [Spanish] Un estudio extension del Programa de Financiamiento para el Ahorro de Energia Electrica busco evaluar el potencial de ahorro de energia electrica alcanzado por el reemplazo de equipos de aire acondicionado y la aplicacion de aislamiento termico en 30 viviendas de dos ciudades mexicanas con clima calido. En un esfuerzo conjunto con la Comision Federal de Electricidad se analizaron los historiales de consumo de los usuarios y se efectuaron las mediciones de campo de demanda electrica y de refrigeracion. Como paso siguiente se valoro el cambio en las necesidades de refrigeracion derivado de la aplicacion de aislamiento termico al igual que la mejora en eficiencia energetica obtenida por la sustitucion de aire acondicionado y se identificaron los resultados favorecedores arrojados por la implementacion de ambas medidas -aislamiento termico y cambio de equipo de aire acondicionado- en forma conjunta. De esta manera, como conclusion, se devela la mas optima secuencia de aplicacion de estas medidas.

  13. Heat pumping using the thermal earth gradient to produce air conditioned and hot water with savings of up to 70%; Bombeo de calor utilizando el gradiente termico de la tierra para producir aire acondicionado y agua caliente con ahorros de hasta un 70%

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Ramirez, Alejandro [Novaenergia de Mexico S.A. de C.V. (Mexico)

    2003-07-01

    The pumping of heat using the Earth heat as partial energy source bases its principle on which the energy of the ground is constant and the energy efficiency to produce air conditioning and hot water simultaneously is important, obtaining savings up to 70%, comparing itself with the traditional equipment and what these operate of separated way to produce each one of them the cold air and the hot water. The use of this technology presents an opportunity to reduce the energy costs of and the demand of the company. [Spanish] El bombeo de calor utilizando el calor de la tierra como fuente parcial de energia basa su principio en que la energia del suelo es constante y el rendimiento energetico para producir simultaneamente aire acondicionado y agua caliente es importante, obteniendose ahorros hasta de un 70%, comparandose con los equipos tradicionales y que estos operan de manera separada para producir cada uno de ellos el aire frio y el agua caliente. El uso de esta tecnologia presenta una oportunidad para reducir los costos de energia y demanda de la empresa.

  14. Energy saving: optimal use of air conditioning equipment by means of the solar control; Ahorro de energia: uso optimo de los acondicionadores de aire mediante el control solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico (Mexico)

    2001-09-01

    In this article the evaluation of the solar heat gains through the transparent parts of a building (houses of social interest) is presented; with the purpose of determining the heat gains through windows during summer time and under the following conditions: without solar protection, with the use of eaves, solar breakers and, finally, with the use of both elements. With the determined percentage of the diminution of heat gains, the considered potential of energy saving in air conditioning was obtained that would be available if the houses were constructed with solar control. [Spanish] En este articulo se presenta la evaluacion de las ganancias de calor solar a traves de las partes transparentes de un edificio (viviendas de interes social); con el objeto de determinar las ganancias de calor a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin proteccion solar, con el empleo de aleros, con quiebrasoles y, finalmente, con el empleo de ambos elementos. Con el porcentaje determinado de la disminucion de ganancias de calor, se obtuvo el potencial estimado de ahorro de energia en aire acondicionado que se tendria si las viviendas se construyen con control solar.

  15. Seismic fragility capacity of equipment--horizontal shaft pump test

    International Nuclear Information System (INIS)

    Iijima, T.; Abe, H.; Suzuki, K.

    2005-01-01

    The current seismic fragility capacity of horizontal shaft pump is 1.6 x 9.8 m/s 2 (1.6 g), which was decided from previous vibration tests and we believe that it must have sufficient margin. The purpose of fragility capacity test is to obtain realistic seismic fragility capacity of horizontal shaft pump by vibration tests. Reactor Building Closed Cooling Water (RCW) Pump was tested as a typical horizontal shaft pump, and then bearings and liner rings were tested as important parts to evaluate critical acceleration and dispersion. Regarding RCW pump test, no damage was found, though maximum input acceleration level was 6 x 9.8 m/s 2 (6 g). Some kinds of bearings and liner rings were tested on the element test. Input load was based on seismic motion which was same with the RCW pump test, and maximum load was equivalent to over 20 times of design seismic acceleration. There was not significant damage that caused emergency stop of pump but degradation of surface roughness was found on some kinds of bearings. It would cause reduction of pump life, but such damage on bearings occurred under large seismic load condition that was equivalent to over 10 to 20 g force. Test results show that realistic fragility capacity of horizontal shaft pump would be at least four times as higher as current value which has been used for our seismic PSA. (authors)

  16. Program of actions for energy conservation in the equipment for the urban public transportation; Programa de acciones para el ahorro de la energia en los equipos de transporte publico urbanos

    Energy Technology Data Exchange (ETDEWEB)

    Sanhez Arellano, L.I. [Facultad de Ingenieria, Universidad Autonoma del Estado de Mexico, Toluca (Mexico)

    1995-12-31

    The Facultad de Ingenieria of the Universidad Autonoma del Estado de Mexico (UAEM), in its postgraduate program in Transport Engineering carries out research projects aimed at the appropriate operation of the urban public transportation, in the definition of the transportation networks and their exploitation as well as in the energy conservation and efficient use of the energy for its operation. This paper embodies the lines of interest of this program. The proper operation characteristics and the energy consumption of the different types of vehicles used in urban public transportation mainly depend on the application they have been designed for. Nevertheless, an important point is to know, in the most concrete and specific form, the nature and other possible utilization options of the different urban transportation systems, as well as its energy impact and the possibility of a well oriented energy conservation. The purpose of this paper is to present in a concrete manner the different types of vehicles used in the urban public transportation, making an energy comparison, besides setting forth a program of actions tending to the energy saving for the vehicles that nowadays operate in the main cities of our country. The main actions are pointed out and the basic characteristics for their initiation, which can be summarized in three large groups: -action in the proper enterprises and with existing vehicular park. -actions over the management and exploitation of the transportation systems. -action for the utilization of new equipment and more efficient vehicles. A detailed explanation of each one of these actions and their impact on the energy consumption are the final purpose of this study. [Espanol] La Facultad de Ingenieria de la Universidad Autonoma del Estado de Mexico (UAEM), dentro de su programa de Postrado en Ingenieria del Transporte realiza proyectos de investigacion tendientes en la buena operacion de los transportes publicos urbanos, en la definicion de

  17. Program of actions for energy conservation in the equipment for the urban public transportation; Programa de acciones para el ahorro de la energia en los equipos de transporte publico urbanos

    Energy Technology Data Exchange (ETDEWEB)

    Sanhez Arellano, L I [Facultad de Ingenieria, Universidad Autonoma del Estado de Mexico, Toluca (Mexico)

    1996-12-31

    The Facultad de Ingenieria of the Universidad Autonoma del Estado de Mexico (UAEM), in its postgraduate program in Transport Engineering carries out research projects aimed at the appropriate operation of the urban public transportation, in the definition of the transportation networks and their exploitation as well as in the energy conservation and efficient use of the energy for its operation. This paper embodies the lines of interest of this program. The proper operation characteristics and the energy consumption of the different types of vehicles used in urban public transportation mainly depend on the application they have been designed for. Nevertheless, an important point is to know, in the most concrete and specific form, the nature and other possible utilization options of the different urban transportation systems, as well as its energy impact and the possibility of a well oriented energy conservation. The purpose of this paper is to present in a concrete manner the different types of vehicles used in the urban public transportation, making an energy comparison, besides setting forth a program of actions tending to the energy saving for the vehicles that nowadays operate in the main cities of our country. The main actions are pointed out and the basic characteristics for their initiation, which can be summarized in three large groups: -action in the proper enterprises and with existing vehicular park. -actions over the management and exploitation of the transportation systems. -action for the utilization of new equipment and more efficient vehicles. A detailed explanation of each one of these actions and their impact on the energy consumption are the final purpose of this study. [Espanol] La Facultad de Ingenieria de la Universidad Autonoma del Estado de Mexico (UAEM), dentro de su programa de Postrado en Ingenieria del Transporte realiza proyectos de investigacion tendientes en la buena operacion de los transportes publicos urbanos, en la definicion de

  18. Process pump operating problems and equipment failures, F-Canyon Reprocessing Facility, Savannah River Plant

    International Nuclear Information System (INIS)

    Durant, W.S.; Starks, J.B.; Galloway, W.D.

    1987-02-01

    A compilation of operating problems and equipment failures associated with the process pumps in the Savannah River Plant F-Canyon Fuel Reprocessing Facility is presented. These data have been collected over the 30-year operation of the facility. An analysis of the failure rates of the pumps is also presented. A brief description of the pumps and the data bank from which the information was sorted is also included

  19. Proceedings of the 24. National seminar on the rational use of energy and exposition of equipment and services and 7. Binational seminar on energy saving [Selected Papers]; 24. Seminario nacional sobre el uso racional de energia y exposicion de equipos y servicios y 7. Seminario binacional de ahorro de energia. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This document contains the technical briefings of the 24. National Seminar on the rational use of energy, and exhibition of the equipment and services and the 7. Binational seminar on energy saving, organized by the Asociacion de Profesionistas y Tecnicos en Aplicacion Energetica (ATPAE), in Ciudad Juarez, Chihuahua, Mexico, from November 9 to 11, 2005. This seminar dealt with subjects such as: electrical energy saving, energy distribution, solar energy, energy saving in compressed air, biomass, administration and control of the demand of the electrical energy, bioclimatic architecture, use of the compressed natural gas, renewable energy, co-generation, qualification and consultancy for the intelligent use of the energy in PyMES. [Spanish] Este documento contiene la memoria tecnica del 24 Seminario Nacional sobre el uso racional de energia, y exposicion de los equipos y servicios y el 7 Seminario binacional de ahorro de energia, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Ciudad Juarez, Chihuahua, Mexico, del 9 al 11 de noviembre del 2005. Este seminario trato temas tales como: ahorro de energia electrica, distribucion de la energia, energia solar, ahorro de energia en aire comprimido, biomasa, administracion y control de la demanda de la energia electrica, arquitectura bioclimatica, uso del gas natural comprimido, energia renovable, cogeneracion, capacitacion y consultoria para el uso inteligente de la energia en las Pymes.

  20. Equipment for checking bearing tolerances in sealed pumps, especially for nuclear engineering

    International Nuclear Information System (INIS)

    Zajic, V.

    1980-01-01

    The equipment consists of a guide pin passing through a coaxial telescopic insert mounted in a support nut for connection to the pump suction branch. The guide pin is fitted with a shoulder engaging with the pump flywheel and comprises a pin for exerting torsional, pitching and sliding motion. The support nut is provided with two guide surfaces (on the front face and on the circumference). A third guide surface is on the guide pin face. (H.S.)

  1. 78 FR 11996 - Energy Efficiency Program for Commercial and Industrial Equipment: Commercial and Industrial Pumps

    Science.gov (United States)

    2013-02-21

    .... EERE-2011-BT-STD-0031] RIN 1904-AC54 Energy Efficiency Program for Commercial and Industrial Equipment: Commercial and Industrial Pumps AGENCY: Office of Energy Efficiency and Renewable Energy, Department of... CONTACT: Mr. Charles Llenza, U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy...

  2. Investigation on the influence of jetting equipment on the characteristics of centrifugal pump

    Directory of Open Access Journals (Sweden)

    Qiaorui Si

    2016-08-01

    Full Text Available To reduce radial noises from the motor of centrifugal pumps, this study designed a water cooling system called jetting equipment to replace traditional fan cooling systems in pump motors. By measuring radiated noises, head, efficiency, and cavitation performance, the research compared the differences among experimental results of the original pump unit, the one with a normal design jetting pipe and another one with a larger jetting pipe. Results show that the radiated sound pressure level of the model pump was significantly reduced by 8.3 dB after integrating the jetting pipe. With a normal jetting pipe, no significant changes were observed in the head, efficiency, and shaft power curves, and cavitation performance improved under small flow rate. However, the performance with the larger jetting pipe worsened, except the hump phenomenon of the model pump under a small flow rate was enhanced. Computational fluid dynamics method was used to calculate the internal flow of three model pumps in order to investigate the jetting flow effect. A comparison among the flow fields at the inlet of the three types of pumps indicated that high-pressure water injection can effectively control inlet recirculation and improve velocity distribution in the inlet flow field with decreased recirculation vortex strength and recirculation onset critical flow rate.

  3. Nuclear waste inventory characterization for mixer pumps and long length equipment removed from Hanford waste tanks

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1998-01-01

    The removal and disposition of contaminated equipment from Hanford high-level nuclear waste tanks presents many challenges. One of which is the characterization of radioactive contaminants on components after removal. A defensible assessment of the radionuclide inventory of the components is required for disposal packaging and classification. As examples of this process, this paper discusses two projects: the withdrawal of thermocouple instrument tubes from Tank 101-AZ, and preparation for eventual replacement of the hydrogen mitigation mixer pump in Tank 101-SY. Emphasis is on the shielding analysis that supported the design of radiation detection systems and the interpolation of data recorded during the equipment retrieval operations

  4. Sodium--NaK engineering handbook. Volume IV. Sodium pumps, valves, piping, and auxiliary equipment

    International Nuclear Information System (INIS)

    Foust, O.J.

    1978-01-01

    The handbook is useful for designers in the Liquid Metals Fast Breeder Reactor (LMFBR) program and by the engineering and scientific community performing investigation and experimentation requiring high-temperature Na and NaK technology. Data are presented for pumps, bearings and seals, valves, vessels and piping, and auxiliary equipment including vapor traps, freeze plugs, fuel-channel flow regulators, antivortexing devices, and miscellaneous mechanical elements. Reactor materials are also discussed

  5. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner Equipment that are effective as of September 15, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=airsrc_heat.pr_crit_as_heat_pumps Listed products have been submitted to EPA by ENERGY STAR partners that do not participate in the AHRI certification program. EPA will continue to update this list with products that are certified by EPA-recognized certification bodies other than AHRI. The majority of ENERGY STAR products, certified by AHRI, can be found on the CEE/AHRI Verified Directory at http://www.ceedirectory.org/

  6. Design, construction and testing of replacement nuclear coolant pump stators to meet today's equipment reliability expectations

    International Nuclear Information System (INIS)

    Fostier, L.; Howell, D.

    2005-01-01

    The reliability expectations of equipment and components in today's nuclear power plant are much greater than three or more decades ago when nuclear plants were first constructed due to economic impact of a failure. Very few components in a pressurized water reactor plant can have as much impact of the plants capacity factor as a catastrophic failure of a reactor coolant pump winding. This paper describes the maintenance approach taken by one North American utility in attempt to preclude such failures. The paper will discuss the challenges of the reactor coolant pump application and the enhancements made in the winding design and construction by the supplier to address failure mechanisms so as to better meet present reliability expectations in accordance with dedicated specifications. The paper will also present the in-process and final testing requirements and limits imposed in an attempt to ensure quality of the machine windings, along with selected test results from the stators that have been designed and constructed to these specifications to date. (author)

  7. EL AHORRO DE LOS HOGARES EN COLOMBIA

    OpenAIRE

    Ligia Melo B.; Héctor Zárate S.; Juana Tellez C.

    2006-01-01

    En este documento se presenta un análisis del comportamiento del ahorro de los hogares y sus determinantes, considerando una perspectiva de largo plazo para el periodo 1950-2004 y una de corto plazo a nivel microeconómico, utilizando la información de las encuestas de calidad de vida de 1997 y 2003. A nivel agregado, con base en un análisis de cointegración se encontró una relación de largo plazo entre la tasa de ahorro de los hogares, el PIB per-cápita, los impuestos directos y una medida de...

  8. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  9. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner...

  10. Electric power saving in the drinkable water, sewage and sanitation system, La Piedad; Ahorro de energia electrica en el sistema de agua potable, alcantarillado y saneamiento de La Piedad

    Energy Technology Data Exchange (ETDEWEB)

    Sistema de Agua Potable, Alcantarillado y Saneamiento de la Piedad (Mexico). E-mail: sapaslapiedad@prodigy.net.mx

    2006-04-15

    In Michoacan, Mexico, a project who seeks to benefice the Municipal public resources was crated in 1994. It would be achieved trough the electric power saving in the public lighting system, and drinkable water pumping and black water, since those activities required the budget biggest part. The program could be developed recently and the saving was significant. In addition the electromechanical efficiency increased in the equipment installation. This work is an example for other States to do something similar that can improve their conditions. [Spanish] En el estado de Michoacan, Mexico se creo un proyecto en el ano de 1994, el cual buscaba beneficiar los recursos publicos municipales, a traves del ahorro de la energia electrica en los sistemas de alumbrado publico y bombeo de agua potable y aguas negras, ya que estas actividades son las que requieren la mayor parte del presupuesto. El programa pudo llevarse a cabo en anos recientes y el ahorro fue significativo, ademas de que aumento la eficiencia electromecanica en los equipos que se instalaron, y esta obra ha servido de ejemplo a otros estados para que realicen algo similar que pueda mejorar su situacion.

  11. Experimental Analysis of Variable Capacity Heat Pump Systems equipped with a liquid-cooled frequency inverter

    OpenAIRE

    Ebraheem, Thair

    2013-01-01

    Using an inverter-driven compressor in variable capacity heat pump systems has a main drawback, which is the extra loss in the inverter. The present experimental study aims to recover the inverter losses by using brine-cooled and water-cooled inverters, thereby improving the total efficiency of the heat pump system. In order to achieve this goal, a test rig with the air-cooled, water-cooled and brine-cooled inverters is designed and built, and a comparative analysis of the recovered heat, inv...

  12. Pump

    International Nuclear Information System (INIS)

    Mole, C.J.

    1983-01-01

    An electromagnetic pump for circulating liquid -metal coolant through a nuclear reactor wherein opposite walls of a pump duct serve as electrodes to transmit current radially through the liquid-metal in the ducts. A circumferential electric field is supplied to the liquid-metal by a toroidal electromagnet which has core sections interposed between the ducts. The windings of the electromagnet are composed of metal which is superconductive at low temperatures and the electromagnet is maintained at a temperature at which it is superconductive by liquid helium which is fed through the conductors which supply the excitation for the electromagnet. The walls of the ducts joining the electrodes include metal plates insulated from the electrodes backed up by insulators so that they are capable of withstanding the pressure of the liquid-metal. These composite wall structures may also be of thin metal strips of low electrical conductivity backed up by sturdy insulators. (author)

  13. Check valve slam waterhammer in piping systems equipped with multiple parallel pumps

    International Nuclear Information System (INIS)

    Sponsel, J.; Bird, E.; Zarechnak, A.

    1993-01-01

    The low pressure safety injection system at the calvert cliff's plant is designed to provide cooling water to the reactor in the event of a postulated accident and for reactor cool-down and decay heat removal during normal maintenance and refueling. This system experienced repeated damage to the axial piping supports on the pump section and the discharge headers due to the check valve phenomenon. To determine the cause, testing was performed in both the LPSI and CCW systems

  14. Ahorro para el retiro en Colombia: patrones y determinantes

    OpenAIRE

    Guataquí, Juan; Rodríguez Acosta, Mauricio; Garcia-Suaza, Andres

    2009-01-01

    La decisión de los individuos acerca del ahorro para el retiro ha sido abordada teóricamente bajo la hipótesis de que el sistema de seguridad social se comporta como un sustituto de otros mecanismos de ahorro. Este documento presenta evidencia de los patrones y determinantes del ahorro para el retiro en Colombia a partir de la Gran Encuesta Integrada de Hogares de 2007. Los resultados muestran que el 63% de los ocupados declaran no ahorrar para su vejez. A partir de modelos de selección d...

  15. Cajas de ahorro, bancarización e inestabilidad financiera

    Directory of Open Access Journals (Sweden)

    Alicia Girón

    2012-01-01

    Full Text Available Las Cajas de Ahorro han sido instituciones financieras emblemáticas del sistema financiero español. A partir del impacto de la crisis en curso sobre las Cajas de Ahorro, el Banco de España las sometió a un proceso de intervención, lo que ha llevado a un proceso de concentración y centralización mediante fusiones para fortalecerse y mejorar sus estados contables, y, así, convertirse en entidades bancarias. La bancarización de las 45 Cajas de Ahorro ha sido la alternativa a la crisis financiera y económica en el sistema financiero español. Estas acciones han permitido una nueva reconfiguración del sector. Ante la profunda inestabilidad financiera por la que atraviesa el sistema financiero, y en particular las Cajas de Ahorro, la bancarización no resuelve el problema de origen.

  16. Presentation of accessibility equipment for primary pipings, IHX, pumps and appertaining manipulator tests

    International Nuclear Information System (INIS)

    Hahn, G.; Hoeft, E.

    1980-01-01

    Accessibility and inservice procedure of SNR-300 components are described. Due to the high radiation level in the primary system it was necessary to develop special equipment to permit access to the testing components. The pertinent examination methods for surveying welding seams are acoustic (ultrasonic) and optical procedures (TV cameras, surface crack tests). This can be done by remote-controlled manipulators and special devices, which can transport the inspection system by rails to the testing position. Presently, relatively limited experience exists for such remote-controlled handling in nuclear power plants. Thus model experiments were carried out on a model pipe section at INTERATOM. The performed test shows that the concept planned to perform inservice by using remote-controlled manipulators can be realized successfully. (author)

  17. A model predictive framework of Ground Source Heat Pump coupled with Aquifer Thermal Energy Storage System in heating and cooling equipment of a building

    NARCIS (Netherlands)

    Rostampour Samarin, V.; Bloemendal, J.M.; Keviczky, T.

    2017-01-01

    This paper presents a complete model of a building heating and cooling equipment and a ground source heat pump (GSHP) coupled with an aquifer thermal energy storage (ATES) system. This model contains detailed
    mathematical representations of building thermal dynamics, ATES system dynamics, heat

  18. Standardization for electric energy saving; Normalizacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Diaz, Arturo [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1994-12-31

    This work describes shortly the current legislation on the standardization; as well as the participation of the entities Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) and Programa de Ahorro de Energia (PAESE) in the consulting committees, for the elaboration of the Mexican official standards focussed to electric power saving. [Espanol] El presente trabajo, describe brevemente la legislacion actual sobre la normalizacion; asi como la participacion de las entidades Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) y Programa de ahorro de Energia (PAESE) en los comites consultivos, para la elaboracion de normas oficiales mexicanas enfocadas al ahorro de energia electrica.

  19. Standardization for electric energy saving; Normalizacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Diaz, Arturo [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    This work describes shortly the current legislation on the standardization; as well as the participation of the entities Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) and Programa de Ahorro de Energia (PAESE) in the consulting committees, for the elaboration of the Mexican official standards focussed to electric power saving. [Espanol] El presente trabajo, describe brevemente la legislacion actual sobre la normalizacion; asi como la participacion de las entidades Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) y Programa de ahorro de Energia (PAESE) en los comites consultivos, para la elaboracion de normas oficiales mexicanas enfocadas al ahorro de energia electrica.

  20. Results in energy saving obtained with the application of speed variator in fossil power stations; Resultados de ahorro de energia obtenidos con la aplicacion de variadores de velocidad en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Merlos Rueda, Rosa Maria [Programa de Ahorro de Energia del Sector Electrico (PAESE), Mexico, D. F. (Mexico)

    1999-07-01

    The project of installation of speed variator in fossil power stations (CT's) of Comision Federal de Electricidad (CFE), as an energy saving measure, is a pilot project that began with the support of the Subdivision de Generacion, and promoted by the Energy Saving Program of the Electric Sector (PAESE), with the putting in operation of an equipment in the condensate pump of the Punta Prieta II C. T. U3. The energy saving observed was substantial, fluctuating between the 19.4% at high loads (at 90% load) and the 71.1% at low loads (at 40% load) of the generating unit. With these results, it was decided to extend the scope of the project with the installation of 6 more equipment for equal number of fossil power stations, located in 4 of the 5 Regions of Generation. The fossil power stations, selected for this stage of the project were: C. T. Felipe Carrillo Puerto U1, C.T. Lerma U4, C.T. Salamanca U1, C.T. Monterrey U6, C.T. Francisco Villa U3 and the C.T. Punta Prieta II-U1. The equipment was in operation during the first quarter of 1998, and the first results indicate an energy savings average per equipment, between 39% and 52%. The recovery of the investment fluctuates between the 48.4% and the 87.6% in less than two years of operation, with which a maximum period of recovery of 3 years is expected. The estimated potential of energy saving, considering the application of these devices in condensate pumps, feedwater pumps (where no speed variator is installed) forced draft fans, induced draft fans and gas recirculation fans, as well as circulation water pumps, of the existing Generating Power stations, ascends to an annual total of 830,000, which represents an approximate 9.4% of the National consumption of self services. [Spanish] El proyecto de instalacion de variadores de velocidad en Centrales Termoelectricas (CT's) de la Comision Federal de Electricidad (CFE), como medida de ahorro de energia, es un proyecto piloto que se inicio con el apoyo de la

  1. Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump and Heat Recovery Equipment in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard; Nigusse, Bereket; Domitrovic, Ron

    2013-09-30

    The University of Central Florida/Florida Solar Energy Center, in cooperation with the Electric Power Research Institute and several variable-refrigerant-flow heat pump (VRF HP) manufacturers, provided a detailed computer model for a VRF HP system in the United States Department of Energy's (U.S. DOE) EnergyPlus? building energy simulation tool. Detailed laboratory testing and field demonstrations were performed to measure equipment performance and compare this performance to both the manufacturer's data and that predicted by the use of this new model through computer simulation. The project goal was to investigate the complex interactions of VRF HP systems from an HVAC system perspective, and explore the operational characteristics of this HVAC system type within a laboratory and real world building environment. Detailed laboratory testing of this advanced HVAC system provided invaluable performance information which does not currently exist in the form required for proper analysis and modeling. This information will also be useful for developing and/or supporting test standards for VRF HP systems. Field testing VRF HP systems also provided performance and operational information pertaining to installation, system configuration, and operational controls. Information collected from both laboratory and field tests were then used to create and validate the VRF HP system computer model which, in turn, provides architects, engineers, and building owners the confidence necessary to accurately and reliably perform building energy simulations. This new VRF HP model is available in the current public release version of DOE?s EnergyPlus software and can be used to investigate building energy use in both new and existing building stock. The general laboratory testing did not use the AHRI Standard 1230 test procedure and instead used an approach designed to measure the field installed full-load operating performance. This projects test methodology used the air

  2. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  3. Pumping systems characterization; Caracterizacion de los sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Torres Gutierrez, R. [Eficiencia Energetica, S.A. de C.V., Mexico, D. F. (Mexico)

    1995-12-31

    In this paper the characterization of the pumping systems is discussed, and an explanation is given of the need of evaluating in detail the possibility of implementing the frequency variators as an option for energy conservation, explaining how the simple use of the similarity or affinity laws lead to over-estimate the saving. [Espanol] En este articulo se describe la caracterizacion de los sistemas de bombeo y se explica la necesidad de evaluar en detalle la posibilidad de implementacion de variadores de frecuencia, como una alternativa para el ahorro de energia, explicando como el simple uso de las leyes de semejanza o afinidad llevan a sobre-evaluar los ahorros.

  4. Pumping systems characterization; Caracterizacion de los sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Torres Gutierrez, R [Eficiencia Energetica, S.A. de C.V., Mexico, D. F. (Mexico)

    1996-12-31

    In this paper the characterization of the pumping systems is discussed, and an explanation is given of the need of evaluating in detail the possibility of implementing the frequency variators as an option for energy conservation, explaining how the simple use of the similarity or affinity laws lead to over-estimate the saving. [Espanol] En este articulo se describe la caracterizacion de los sistemas de bombeo y se explica la necesidad de evaluar en detalle la posibilidad de implementacion de variadores de frecuencia, como una alternativa para el ahorro de energia, explicando como el simple uso de las leyes de semejanza o afinidad llevan a sobre-evaluar los ahorros.

  5. EN LAS CAJAS DE AHORROS ESPAÑOLAS

    Directory of Open Access Journals (Sweden)

    Isidoro Guzmán

    2011-01-01

    Full Text Available El rendimiento del sector financiero español ha sido objeto de diversos estudios alo largo del decenio de los novena del sigloXXcomo consecuencia de los impor-tantes cambios a los que ha estado sometido. Las cajas de ahorros españolas nohan sido ajenas a este tipo de estudios, si bien circunscritos de manera exclusiva alexamen de su eficiencia y productividad, relegando a un segundo plano el análisisdel cumplimiento de su fin social, materializado económicamente en el gasto anualdestinado a obra social.En este contexto, la principal aportación de nuestro estudio es la obtención deevidencia empírica de la existencia de una relación de causalidad entre la creaciónde valor social de las cajas de ahorro españolas, medida por medio del estableci-miento de unratiode gasto social, y sus cambios en productividad, cuantificadosmediante el cálculo del índice de productividad de Malmquist basado en el trazadode fronteras eficientes a partir de la técnica no paramétrica del análisis envolvente dedatos (AED (Data Envelopment Analysis,DEA.Para el censo de cajas de ahorro españolas en el periodo 2003-2007, nuestrosresultados revelan que las entidades que presentan mayor productividad alcanzancotas superiores en elratiode gasto social, incluso después de controlar por medi-das tradicionales como la rentabilidad económica y el tamaño.

  6. Energy saving in the management of the BIMBO group distribution fleet; Ahorro de energia en la operacion de la flotilla de distribucion del grupo BIMBO

    Energy Technology Data Exchange (ETDEWEB)

    Mexico, BIMBO

    2005-07-01

    In this work BIMBO demonstrates that in order to save energy it is necessary to invest in equipment, parts, research and people. This is why they got involved in the task of developing the projects of fuel cells participating with universities, associations, Secretaria de Energia, Comision Nacional de Ahorro de Energia (National Commission for Energy Saving) (CONAE) and the National Council for Science and Tecnologia (CONACYT), through financial supports with projects of mechanisms of clean development (Kyoto Protocol). For doing it they had to prove different types of fuels: biodiesel, hydrogen, alcohol and hybrids; for them to determine the most profitable and practical thus reducing the energy consumption. With the saving of fuels and lubricants in our vehicles, a greater yield in the company is obtained. [Spanish] En este trabajo BIMBO demuestra que para ahorrar energia hay que invertir en equipo, partes, investigacion y gente. Es por eso que se dieron a la tarea de desarrollar los proyectos de celdas de combustible, participando con universidades, asociaciones, la Secretaria de Energia, la Comision Nacional para el Ahorro de Energia (CONAE) y el Consejo Nacional para la Ciencia y Tecnologia (CONACYT), a traves de apoyos financieros con proyectos de mecanismos de desarrollo limpio (protocolo de Kyoto). Para ello tuvieron que probar diferentes tipos de combustibles: biodiesel, hidrogeno, alcohol e hibridos, para determinar los mas rentables y practicos y asi reducir el consumo de energia; con el ahorro de combustibles y lubricantes en nuestros vehiculos, logrando una mayor rentabilidad en la empresa.

  7. Strategies for energy saving in warm climate dwellings; Estrategias de ahorro de energia para viviendas en clima calido

    Energy Technology Data Exchange (ETDEWEB)

    Pilatowsky, I [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico (Mexico); Ramos Niembro, Gaudencio [Comision Nacional para el Ahorro de Energia -CONAE (Mexico); Morillon, David [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (Mexico); Oskam, A. [Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-04-15

    The domestic sector consumes almost one quarter of the national electrical energy. In order to reduce in an important manner the power consumption in dwellings there is an integral alternative based on three elements: the bio-climatic design, the saving and efficient use of the energy in equipment and apparatuses, and the use of centralized air conditioning systems. Besides saving the electrical and thermal power consumption, with this scheme, comfort conditions are pretended to be reached in dwellings and, contributing at the same time, to the diminution of polluting emissions. [Spanish] El sector domestico consume casi una cuarta parte de la energia electrica nacional. Con objeto de reducir de manera importante el consumo de energia en las viviendas, se presenta una alternativa integral, basada en tres elementos: el diseno bioclimatico, el ahorro y uso eficiente de la energia en equipos y aparatos, y la utilizacion de sistemas de climatizacion centralizados. Ademas del ahorro en el consumo de energia electrica y termica, con este esquema se pretende alcanzar condiciones de confort en las viviendas y, al mismo tiempo, contribuir a la disminucion de emisiones contaminantes.

  8. Utilization of the computational technic for the promotion and diffusion of the energy conservation practice; Utilizacion de tecnicas computacionales para promocionar y difundir el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Kemper Valverde, N. [Laboratorio de Inteligencia Artificial, Instituto de Ingenieria, UNAM, Mexico D. F. (Mexico)

    1995-12-31

    In this paper are presented the developments obtained through the application of the new computational technologies in the diffusion and promotion tasks of energy efficient use and conservation. The most relevant aspects are described of three multimedia courses that were designed in order to increase the possibilities of offering personal training in efficient energy technic, as well as to have on hand totally open consulting and interactive tools. The courses that are described are: ``Design of Energy Conservation Programs for the Industry``, ``Energy Conservation in Combustion Equipment`` and ``Energy Cogeneration Technologies.`` On another subject, an analysis is also made of the possibilities for the development and application of expert systems that advise and give support to the work of technicians and engineers dedicated to energy conservation. The main characteristics of an expert system to give support to the energy analysis of lighting industrial systems, malls, buildings and hotels are also described. [Espanol] En este trabajo se presentan los desarrollos obtenidos por la aplicacion de las tareas de difusion y promocion del uso eficiente y ahorro de energia. Se describen los aspectos mas relevantes de tres cursos multimedia que fueron disenados con el objeto de incrementar las posibilidades de brindar capacitacion individualizada en tecnicas energeticas eficientes, asi como de contar con herramientas de consulta totalmente abiertas e interactivas. Los cursos que se describen son: ``Diseno de Programas de Ahorro de Energia en la Industria,`` ``Ahorro de Energia en Equipos de Combustion`` y ``Tecnologias de Cogeneracion de Energia.`` Por otro lado, tambien se hace un analisis de las posibilidades para el desarrollo y aplicacion de sistemas expertos que asesoren y apoyen el trabajo de tecnicos e ingenieros dedicados al ahorro de energia. Se describen las caracteristicas principales de un sistema experto disenado para brindar apoyo en analisis energeticos

  9. Utilization of the computational technic for the promotion and diffusion of the energy conservation practice; Utilizacion de tecnicas computacionales para promocionar y difundir el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Kemper Valverde, N [Laboratorio de Inteligencia Artificial, Instituto de Ingenieria, UNAM, Mexico D. F. (Mexico)

    1996-12-31

    In this paper are presented the developments obtained through the application of the new computational technologies in the diffusion and promotion tasks of energy efficient use and conservation. The most relevant aspects are described of three multimedia courses that were designed in order to increase the possibilities of offering personal training in efficient energy technic, as well as to have on hand totally open consulting and interactive tools. The courses that are described are: ``Design of Energy Conservation Programs for the Industry``, ``Energy Conservation in Combustion Equipment`` and ``Energy Cogeneration Technologies.`` On another subject, an analysis is also made of the possibilities for the development and application of expert systems that advise and give support to the work of technicians and engineers dedicated to energy conservation. The main characteristics of an expert system to give support to the energy analysis of lighting industrial systems, malls, buildings and hotels are also described. [Espanol] En este trabajo se presentan los desarrollos obtenidos por la aplicacion de las tareas de difusion y promocion del uso eficiente y ahorro de energia. Se describen los aspectos mas relevantes de tres cursos multimedia que fueron disenados con el objeto de incrementar las posibilidades de brindar capacitacion individualizada en tecnicas energeticas eficientes, asi como de contar con herramientas de consulta totalmente abiertas e interactivas. Los cursos que se describen son: ``Diseno de Programas de Ahorro de Energia en la Industria,`` ``Ahorro de Energia en Equipos de Combustion`` y ``Tecnologias de Cogeneracion de Energia.`` Por otro lado, tambien se hace un analisis de las posibilidades para el desarrollo y aplicacion de sistemas expertos que asesoren y apoyen el trabajo de tecnicos e ingenieros dedicados al ahorro de energia. Se describen las caracteristicas principales de un sistema experto disenado para brindar apoyo en analisis energeticos

  10. Factores determinantes del ahorro interno en América Latina

    Directory of Open Access Journals (Sweden)

    Carlos Añez

    2002-01-01

    Full Text Available El siguiente artículo aborda el problema del financiamiento de la inversión para un país en desarrollo, específicamente de la América Latina, tratando de revisar la literatura disponible para llegar a conclusiones sobre cómo los determinantes del ahorro en todas sus versiones -ahorro externo, ahorro privado y ahorro público- ejercen influencia sobre el proceso de crecimiento. Aun cuando la dirección causal exacta entre ahorro y crecimiento no ha sido establecida, el desarrollo de políticas económicas que estimulen el ahorro interno por encima del procedente del exterior, fortalecerían la capacidad de inversión interna y, al existir una correlación positiva entre estas variables, se potencia el proceso de crecimiento aunque otras variables igualmente pueden difuminar tal efecto. Se concluye que el incremento de la relación Ahorro Interno / P. I. B. sólo puede alcanzarse a través de esfuerzos comunes entre empresas, gobierno y el sistema financiero de estas economías.

  11. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  12. Electric power conservation while using pumping systems; Conservacion de Energia Electrica en Sistemas de Bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Nambiar, P

    2007-01-15

    The pumping systems provide about 20 to 25 percent of energy which is necessary worldwide: it is fruitful to understand how to use electric power efficiently, to achieve the reduction regarding expenses a pumping system implies.It is essential to possess a better knowledge about the pumping system and its applications, in order to be able to use energy responsibly. If people do not how to operate this kind of systems properly, they will use inadequate equipment that will cause an energy waste. In addition it is important to know: alternative methods to meet variable demands, an adapted system to pump water requirements in order to ensure the pump work in its pumping point, and the life cycle system cost for the energy saving in the long term. [Spanish] En promedio del 20 al 25% de la energia necesaria en el mundo proviene de los sistemas de bombeo, por tal razon es importante saber como utilizar la energia electrica con eficiencia para asi lograr reducir los gastos que este tipo de sistemas implican. Para poder hacer un buen uso de la energia, es necesario que se tenga un conocimiento mayor del sistema de bombeo y aplicacion, ya que la ignorancia sobre esto exige el uso de aparatos que contribuyen al desperdicio de la energia; por otro lado tambien es esencial conocer metodos alternos para demandas variables, tener un sistema que se adapte a las necesidades de bombeo del agua para asegurarse de que cada bomba trabaje cerca de su punto de bombeo y finalmente conocer el costo del ciclo de vida del sistema para el ahorro de energia a largo plazo.

  13. Project of energy saving in compressed air; Proyecto de ahorro de energia en aire comprimido

    Energy Technology Data Exchange (ETDEWEB)

    Automatizacion, Productividad y Calidad S.A. de C.V. Puebla, (Mexico)

    2005-07-01

    The objective of this project is to reduce the operation costs by means of the energy saving through the use of the compressed air system. For this purpose the solenoid valves controlled per time and the manually acted valves of sphere must be replaced by pneumatic purges that remove from the system the condensed humidity without discharging air and which act automatically when the water reaches the level of unloading in its deposit. The pressure level is the reduction of the operation rank of pressure in the compressors, satisfying the operation requirements of the process equipment. [Spanish] El objetivo de este proyecto es reducir el costo de operacion mediante el ahorro de energia en la utilizacion del sistema de aire comprimido. Para ello se tienen que remplazar las valvulas solenoides controladas por tiempo y valvulas de esfera actuadas manualmente por purgas neumaticas que remueven del sistema la humedad condensada sin descargar aire y que actuan en forma automatica al alcanzar el agua el nivel de descarga en su deposito. El nivel de presion es la reduccion del rango de operacion de presion de los compresores, satisfaciendo los requerimientos de operacion de los equipos de proceso.

  14. Diferencias de género en los factores asociados al ahorro de los hogares en México

    OpenAIRE

    Isalia Nava Bolaños; Flor Brown Grossman; Lilia Domínguez Villalobos

    2014-01-01

    A diferencia de los trabajos que analizan el ahorro suponiendo un hogar unitario, esta investigación se centra en las diferencias en las decisiones de ahorro de los hogares con jefaturas femenina y masculina en México. Los resultados del modelo Tobit muestran que los factores que afectan al ahorro son distintos entre ellos. La escolaridad (primaria y secundaria) y los apoyos gubernamentales no inciden en las tasas de ahorro de las jefaturas masculinas, pero sí en las femeninas. Se confirma la...

  15. Diferencias de género en los factores asociados al ahorro de los hogares en México

    OpenAIRE

    Nava Bolaños, Isalia; Brown Grossman, Flor; Domínguez Villalobos, Lilia

    2014-01-01

    A diferencia de los trabajos que analizan el ahorro suponiendo un hogar unitario, esta investigación se centra en las diferencias en las decisiones de ahorro de los hogares con jefaturasfemenina y masculina en México. Los resultados del modelo Tobit muestran que los factores que afectan al ahorro son distintos entre ellos. La escolaridad (primaria y secundaria) y los apoyos gubernamentales no inciden en las tasas de ahorro de las jefaturas masculinas, pero sí en las femeninas. Se confirma la ...

  16. Risk control in energy saving projects; Control de riesgo en los proyectos de ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan [Lawrence Berkeley National Laboratory, CA (United States)

    2005-10-15

    Since one of the restrictive problems when investing in energy saving is the uncertainty of obtaining the planed savings, a technique in the risk handling for energy efficiency projects, called Insurance for the Energy Saving (IES) is presented. IES economically stimulates those who implement projects for energy saving so they go beyond the normal measures and really obtain significant saving levels, thus contributing to the fulfillment of national objectives in energy saving. In order to reduce the risk of low performance in energy caused by saving projects there exist the international performance measurement and the protocol of investment (IMPVP) as well as diagnoses and starting processes, whereas in order to transfer the financial risk that a saving project represents, mechanisms such as FDIC insurance, conversion of the debt in values, Saving's Guarantees, Performance Bonuses or Guarantee Bonuses and Insurances for Energy Saving can be of great help. This article deals on the IES insurance policies, their loss control management, successful cases, benefits, particular advantages, place in the market and refers argued insurance exceptions and perception surveys. [Spanish] Dado que uno de los problemas restrictivos a la hora de invertir en el ahorro de energia es la incertidumbre de obtener los ahorros proyectados, se presenta una tecnica en el manejo del riesgo para proyectos de eficiencia energetica llamada Seguro para el Ahorro de Energia (SAE). SAE estimula financieramente a quienes implementan proyectos para el ahorro de energia con el fin de que vayan mas alla de las medidas normales y consigan niveles significativos de ahorro, contribuyendo asi al cumplimiento de objetivos nacionales de ahorro energetico. Para reducir el riesgo de bajo desempeno de energia provocados por proyectos de ahorro existe la medicion del desempeno internacional y el protocolo de inversion (IMPVP) asi como diagnosticos y procesos de arranque, mientras que para transferir el

  17. Estrategias que permitan mejorar los productos de inversión y ahorro de las cooperativas de ahorro y crédito de la ciudad de Machala, caso: Cooperativa de Ahorro y Crédito Once de Junio Ltda.

    OpenAIRE

    Moran Molina, Germán Gracián

    2015-01-01

    El presente trabajo de investigación, titulado “Estrategias que permitan mejorar los productos de inversión y ahorro de las Cooperativas de ahorro y crédito de la ciudad de Machala, Caso: Cooperativa de Ahorro y Crédito Once de Junio Ltda.”, propone buscar un nuevo producto financiero que beneficie a una institución financiara netamente orense como lo es la cooperativa de ahorro y crédito “Once de Junio Ltda.” y obviamente a sus socios y clientes, con lo cual buscara afianzarse en el mercado ...

  18. Pump trials for charged liquids

    International Nuclear Information System (INIS)

    Moroni, J.C.; Niver, A.

    1964-01-01

    The pumps intended for the circulation of charged and radioactive liquids have particular qualities. The choice of such a pump has called for endurance tests with various types of equipment: a Goodyear volumetric screw pumps, and RICHIER, Klein and SCHABAVER centrifugal pumps. The latter, fitted with a special oakum, gave the best results. (authors) [fr

  19. Introduction criteria and concepts on energy saving in the technical standards for electric installations; Introduccion de criterios y conceptos de ahorro de energia en las normas tecnicas para instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Nader, Jorge A [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1993-12-31

    The project Introduction Criteria and Concepts on Energy Saving in the Technical Standards for electric installations, is described, whose immediate objective is to recommend and in some cases regulate the use of energy saving equipment and devices and the adoption of attitudes and procedures that convey into saving, and the rational and efficient use of the electric energy. [Espanol] Se describe el proyecto Introduccion de Criterios y Conceptos de Ahorro de Energia en las Normas Tecnicas para instalaciones electricas, que tiene como objetivo inmediato recomendar, y en algunos casos reglamentar el uso de equipos y dispositivos ahorradores y la adopcion de actitudes y procedimientos que conduzcan a un ahorro y uso racional y eficiente de la energia electrica.

  20. Introduction criteria and concepts on energy saving in the technical standards for electric installations; Introduccion de criterios y conceptos de ahorro de energia en las normas tecnicas para instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Nader, Jorge A. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-12-31

    The project Introduction Criteria and Concepts on Energy Saving in the Technical Standards for electric installations, is described, whose immediate objective is to recommend and in some cases regulate the use of energy saving equipment and devices and the adoption of attitudes and procedures that convey into saving, and the rational and efficient use of the electric energy. [Espanol] Se describe el proyecto Introduccion de Criterios y Conceptos de Ahorro de Energia en las Normas Tecnicas para instalaciones electricas, que tiene como objetivo inmediato recomendar, y en algunos casos reglamentar el uso de equipos y dispositivos ahorradores y la adopcion de actitudes y procedimientos que conduzcan a un ahorro y uso racional y eficiente de la energia electrica.

  1. 33 CFR 183.524 - Fuel pumps.

    Science.gov (United States)

    2010-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.524 Fuel pumps. (a) Each...) If tested under § 183.590, each fuel pump, as installed in the boat, must not leak more than five...

  2. Diferencias de género en los factores asociados al ahorro de los hogares en México

    Directory of Open Access Journals (Sweden)

    Isalia Nava Bolaños

    2014-01-01

    Full Text Available A diferencia de los trabajos que analizan el ahorro suponiendo un hogar unitario, esta investigación se centra en las diferencias en las decisiones de ahorro de los hogares con jefaturas femenina y masculina en México. Los resultados del modelo Tobit muestran que los factores que afectan al ahorro son distintos entre ellos. La escolaridad (primaria y secundaria y los apoyos gubernamentales no inciden en las tasas de ahorro de las jefaturas masculinas, pero sí en las femeninas. Se confirma la asociación negativa de las horas dedicadas al trabajo doméstico con la tasa de ahorro en los hogares de jefatura femenina.

  3. Interactive applications for energy saving; Aplicaciones interactivas para ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Adame Gonzalez, Alejandro; Ramirez Anaya, Cesar; Gutierrez, Hector; Dominguez Ojeda, Xerxes; Aguilar Galvan, Alfredo [Ingenieria Energetica Integral S. A. de C. V., Mexico, D. F. (Mexico)

    1998-12-31

    A series of ideas are presented that can help in the development of interactive applications for energy saving. Emphasis is made on the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE)`s Interactive Course on Demand Management and Power Factor Compensation, in order to demonstrate how far one can go with the multimedia development. [Espanol] Se presenta un conjunto de ideas que pueden auxiliar en la elaboracion de aplicaciones interactivas para ahorro de energia. Se hace principal enfasis sobre el curso interactivo Administracion de la Demanda y Compensacion del Factor de Potencia del Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) con la finalidad de mostrar hasta donde puede llegarse con un desarrollo multimedia.

  4. Interactive applications for energy saving; Aplicaciones interactivas para ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Adame Gonzalez, Alejandro; Ramirez Anaya, Cesar; Gutierrez, Hector; Dominguez Ojeda, Xerxes; Aguilar Galvan, Alfredo [Ingenieria Energetica Integral S. A. de C. V., Mexico, D. F. (Mexico)

    1999-12-31

    A series of ideas are presented that can help in the development of interactive applications for energy saving. Emphasis is made on the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE)`s Interactive Course on Demand Management and Power Factor Compensation, in order to demonstrate how far one can go with the multimedia development. [Espanol] Se presenta un conjunto de ideas que pueden auxiliar en la elaboracion de aplicaciones interactivas para ahorro de energia. Se hace principal enfasis sobre el curso interactivo Administracion de la Demanda y Compensacion del Factor de Potencia del Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) con la finalidad de mostrar hasta donde puede llegarse con un desarrollo multimedia.

  5. 33 CFR 157.126 - Pumps.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Pumps. 157.126 Section 157.126... Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.126 Pumps. (a) Crude oil must be supplied to the COW machines by COW system pumps or cargo pumps. (b) The pumps under paragraph...

  6. 46 CFR 169.559 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 169.559 Section 169.559 Shipping COAST GUARD... Firefighting Equipment Firefighting Equipment § 169.559 Fire pumps. (a) Each sailing school vessel must be equipped with fire pumps as required in Table 169.559(a). Table 169.559(a)—Fire Pumps Length Exposed and...

  7. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  8. Strategies for energy saving in buildings by means of automatic control; Estrategias de ahorro de energia en inmuebles mediante el control automatico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Trujillo, Oscar [Johnson Controls de Mexico S. A. de C. V., Mexico, D. F. (Mexico)

    1998-12-31

    In this paper some of the measures and strategies for energy saving that can be applied in different types of buildings, mainly in hotels and office buildings, are presented. The proposed actions are accomplished with the aid of the automatic control equipment and the operation and/or maintenance personnel that supervises and establishes the control parameters of each one of the strategies than are focused to the appropriate utilization of the electric energy. [Espanol] En este documento se presentan algunas de las medidas y estrategias de ahorro de energia que pueden ser aplicadas en diferentes tipos de inmuebles, principalmente en hoteles y en edificios de oficinas. Las acciones propuestas son realizadas con la ayuda del equipo de control automatico y del personal de operacion y/o mantenimiento quien supervisa y establece los parametros de control de cada una de las estrategias que son destinadas a la buena utilizacion de la energia electrica.

  9. Strategies for energy saving in buildings by means of automatic control; Estrategias de ahorro de energia en inmuebles mediante el control automatico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Trujillo, Oscar [Johnson Controls de Mexico S. A. de C. V., Mexico, D. F. (Mexico)

    1999-12-31

    In this paper some of the measures and strategies for energy saving that can be applied in different types of buildings, mainly in hotels and office buildings, are presented. The proposed actions are accomplished with the aid of the automatic control equipment and the operation and/or maintenance personnel that supervises and establishes the control parameters of each one of the strategies than are focused to the appropriate utilization of the electric energy. [Espanol] En este documento se presentan algunas de las medidas y estrategias de ahorro de energia que pueden ser aplicadas en diferentes tipos de inmuebles, principalmente en hoteles y en edificios de oficinas. Las acciones propuestas son realizadas con la ayuda del equipo de control automatico y del personal de operacion y/o mantenimiento quien supervisa y establece los parametros de control de cada una de las estrategias que son destinadas a la buena utilizacion de la energia electrica.

  10. Energy conservation programs of Pemex exploration and production, south region; Programas de ahorro de energia en Pemex exploracion y produccion, region sur

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Milla, Guillermo; Garcia Juarez, Francisco; Alarcon Aleman, Jose Mauricio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1999-12-31

    The technological developments of energy economizing equipment constitute a powerful tool for the conservation and saving of the electric energy in new or existing installations. Petroleos Mexicanos (PEMEX) Exploration and Production initiated in 1997 a program for energy economizing in the South region, for which the Instituto de Investigaciones Electricas, through its Unit for the Use of Energy, collaborated performing energy assessments in 115 buildings of the above mentioned region. This paper describes the employed methodology to carry on the energy assessment, which consisted in an analysis of each building and different options for energy economizing were presented, which was accompanied with cost-benefit studies. The results obtained show that the air conditioning equipment and lighting represent the most important loads permanently connected, therefore the study was concentrated in these two loads [Espanol] Los desarrollos tecnologicos de equipos ahorradores de energia constituyen una poderosa herramienta para la conservacion y el ahorro de energia electrica en instalaciones nuevas o existentes. Petroleos Mexicanos (PEMEX) Exploracion y Produccion inicio en 1997 un programa para el ahorro de energia en la region sur, para lo cual el Instituto de Investigaciones Electricas, a traves de la Unidad de Uso de Energia, colaboro realizando diagnosticos energeticos en 115 edificios de dicha region. En este documento se describe la metodologia utilizada para realizar el diagnostico energetico, el cual consistio en un analisis de cada edificio y se presentaron diversas opciones para ahorrar energia, lo cual se acompano de estudios de costo-beneficio. Los resultados obtenidos muestran que los equipos de aire acondicionado e iluminacion representan la parte mas importante de las cargas conectadas permanentemente, por lo que el estudio se concentro en estas dos cargas

  11. Energy conservation programs of Pemex exploration and production, south region; Programas de ahorro de energia en Pemex exploracion y produccion, region sur

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Milla, Guillermo; Garcia Juarez, Francisco; Alarcon Aleman, Jose Mauricio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The technological developments of energy economizing equipment constitute a powerful tool for the conservation and saving of the electric energy in new or existing installations. Petroleos Mexicanos (PEMEX) Exploration and Production initiated in 1997 a program for energy economizing in the South region, for which the Instituto de Investigaciones Electricas, through its Unit for the Use of Energy, collaborated performing energy assessments in 115 buildings of the above mentioned region. This paper describes the employed methodology to carry on the energy assessment, which consisted in an analysis of each building and different options for energy economizing were presented, which was accompanied with cost-benefit studies. The results obtained show that the air conditioning equipment and lighting represent the most important loads permanently connected, therefore the study was concentrated in these two loads [Espanol] Los desarrollos tecnologicos de equipos ahorradores de energia constituyen una poderosa herramienta para la conservacion y el ahorro de energia electrica en instalaciones nuevas o existentes. Petroleos Mexicanos (PEMEX) Exploracion y Produccion inicio en 1997 un programa para el ahorro de energia en la region sur, para lo cual el Instituto de Investigaciones Electricas, a traves de la Unidad de Uso de Energia, colaboro realizando diagnosticos energeticos en 115 edificios de dicha region. En este documento se describe la metodologia utilizada para realizar el diagnostico energetico, el cual consistio en un analisis de cada edificio y se presentaron diversas opciones para ahorrar energia, lo cual se acompano de estudios de costo-beneficio. Los resultados obtenidos muestran que los equipos de aire acondicionado e iluminacion representan la parte mas importante de las cargas conectadas permanentemente, por lo que el estudio se concentro en estas dos cargas

  12. 46 CFR 181.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 181.300 Section 181.300 Shipping COAST GUARD... EQUIPMENT Fire Main System § 181.300 Fire pumps. (a) A self priming, power driven fire pump must be..., the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not...

  13. La reforma del sistema financiero: cajas de ahorros.- (Años 2011-2012

    Directory of Open Access Journals (Sweden)

    Octavio Vázquez Sotelo

    2013-04-01

    Full Text Available Este trabajo forma parte del libro “La dimensión social de las Cajas de Ahorro: España y Galicia”, publicado por la Editorial Académica Española, del cual soy autor.A través de la legislación promulgada en los años 2010, 2011 y 2012, se analiza la estrategia de privatización de las Cajas de Ahorro seguida por los gobiernos de turno que, en la mayor parte de los casos, ha supuesto la entrega de las mismas a precios irrisorios a su tradicionales competidores: la gran Banca.. Ello ha comportado la desfiguración o, incluso, la desaparición del rasgo más distintivo de aquellas: la Obra Social.

  14. Instituciones microfinancieras y cajas de ahorro en Santo Tomás Hueyotlipan, Puebla

    Directory of Open Access Journals (Sweden)

    Kristiano Raccanello

    2014-01-01

    Full Text Available La exigua presencia de los intermediarios financieros formales en los municipios rurales mexicanos impulsa el uso de tandas y solicitud de dinero a prestamistas, familiares o amigos. Las cajas de ahorro constituyen una alternativa a estos métodos tradicionales y aprovechan el capital social comunitario. Esta investigación, fundamentado en una muestra realizada en el municipio de Santo Tomás Hueyotlipan (Puebla, México, analiza los factores que impulsan la participación en las cajas de ahorro informales y su interacción con otros intermediarios financieros informales. Los resultados del modelo probit indican que la participación responde a la posibilidad de poder ahorrar atrayendo a aquellos individuos que no utilizan tandas, prestamistas o deudas con familiares o amigos.

  15. El efecto del alfabetismo financiero en el ahorro para el retiro en México.

    OpenAIRE

    F. Alejandro Villagómez; Alayn González

    2014-01-01

    En este trabajo analizamos si es posible incrementar el ahorro para el retiro por medio de alfabetismo financiero en México. Con información de la Encuesta Nacional de los Niveles de Vida de los Hogares 2005 (ENNVIH-2) construimos un índice de alfabetizo financiero siguiendo la metodología propuesta por Atkinson y Messy (2012) que considera tres factores: conocimiento, actitudes y comportamiento financiero. Nuestros resultados sugieren que el alfabetismo financiero tiene un impacto positivo e...

  16. Nissan Mexicana. First place in national prize of electrical energy saving 1998; Nissan Mexicana. Primer lugar en premio nacional de ahorro de energia electrica 1998

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez S, Enrique [Nissan Mexicana, S.A. de C.V., Planta Civac, Cuernavaca, Mor. (Mexico)

    1999-07-01

    For Plant CIVAC of Nissan Mexicana, the energy saving began in the year of 1990. From then, different programs have been developed using different strategies for energy saving until arriving at the Benchmarking with other Plants of Japan, which represents a new challenge, since it opened up an area of opportunity of saving in processes that generally were known in detail as far as to its main function (to make vehicles with quality, cost and opportunity of delivery), but the parameter of energy consumption of by unit and its benefits in relation to the cost was unknown. This was endorsed by the high Direction and began with the optimization of training for the operation of each equipment with the involvement of the user (Production), the engineering area (that establishes the process) and the maintenance area. We designed a general program where the basic activities were included, such as the general and special activities. Each one of them fulfilled its objective, but the special activities took us to the optimization of the processes, finding excess of energy in the design conditions. [Spanish] Para Planta CIVAC de Nissan Mexicana, el ahorro de energia se inicio en el ano de 1990. A partir de entonces se han desarrollado programas de ahorro de energia usando estrategias diferentes hasta llegar al Benchmarking con otras Plantas de Japon, el cual representa un reto nuevo, ya que puso al descubierto una area de oportunidad de ahorro en los procesos que por lo general se conocian a detalle en cuanto a la funcion principal (hacer vehiculos con calidad, costo y oportunidad de entrega), pero se desconocia el parametro de consumo de energia por unidad y sus beneficios en relacion con el costo. Esto fue avalado por la alta Direccion y se inicio con la capacitacion de la optimizacion de la operacion de cada equipo y se involucro al usuario (Produccion), al area de ingenieria (que establece el proceso) y al area de mantenimiento. Elaboramos un programa general donde se

  17. Penis Pump

    Science.gov (United States)

    ... your appointment might be less involved. Choosing a penis pump Some penis pumps are available without a ... it doesn't get caught in the ring. Penis pumps for penis enlargement Many advertisements in magazines ...

  18. Circulation pump mounting

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    The suspension is described of nuclear reactor circulating pumps enabling their dilatation with a minimum reverse force consisting of spacing rods supported with one end in the anchor joints and provided with springs and screw joints engaging the circulating pump shoes. The spacing rods are equipped with side vibration dampers anchored in the shaft side wall and on the body of the circulating pump drive body. The negative reverse force F of the spacing rods is given by the relation F=Q/l.y, where Q is the weight of the circulating pump, l is the spatial distance between the shoe joints and anchor joints, and y is the deflection of the circulating pump vertical axis from the mean equilibrium position. The described suspension is advantageous in that that the reverse force for the deflection from the mean equilibrium position is minimal, dynamic behaviour is better, and construction costs are lower compared to suspension design used so far. (J.B.)

  19. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  20. Energy saving in Bellota Mexico S.A. de C.V.; Ahorro de energia en Bellota Mexico S.A de C.V.

    Energy Technology Data Exchange (ETDEWEB)

    Salazar Lopez, Jose Albeiro [Bellota Mexico S.A. de C.V. (Mexico)

    2003-07-01

    The present article intends to make a general description of the different activities that were developed in Bellota Mexico S.A. de C.V. during year 2001 and which lead to obtaining the national prize of energy saving granted by the Comision Federal de Electricidad (CFE) and the Fideicomiso para el Ahorro de Energia Electrica (FIDE). In the executed actions stands out an entirely coordinated program that includes: lighting systems, motors, refrigeration systems, transformers, special projects (settling tanks), capacitors, compressed air pipeline, induction furnaces, machinery in general, maximum demand control, preventive maintenance, measuring systems, operational and organizational systems. In all these subjects a fast description is made of the performed actions and the obtained results. It is mentioned in addition the importance of making a power diagnosis and the use of historical data for the planning of the strategies to follow. Also reference is made of the use of appropriate technology that considers the use of high-energy efficiency equipment, such as motors, lamps, compressors, etc. Finally an evaluation is made of the obtained results where the improvement of the electrical parameters stands out such as: reduction of the power index in 35.06%, reduction of the maximum demand in 11.94%, increase of the power factor from 93.53% in 98.21%. The obtained results demonstrate that investing in energy saving it is a good business. [Spanish] El presente trabajo tiene por objeto hacer una descripcion general de las diferentes actividades que se desarrollaron en Bellota Mexico S.A. de C.V. durante el ano 2001 y que condujeron a la obtencion del premio nacional de ahorro de energia otorgado por la Comision Federal de Electricidad (CFE) y el Fideicomiso para el Ahorro de Energia Electrica (FIDE). En las acciones ejecutadas se destaca todo un programa coordinado que abarca: sistemas de iluminacion, motores, sistemas de refrigeracion, transformadores, proyectos

  1. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  2. Electric energy saving in the cellulose and paper industry; Ahorro de energia electrica en la industria de celulosa y papel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    This paper delineates the results of the demonstration project for electric energy saving, which is one of the twenty four projects in which the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) sponsors the diagnosis as well as the applied measures and the measures currently in application. Also the potential opportunity areas and the measures applied and in course of application, as well as the required investments and their recuperation periods. [Espanol] En este trabajo se describen los resultados del proyecto de demostracion de ahorro de energia electrica que es uno de los veinticuatro proyectos, en los que el Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) financia tanto el diagnostico como la aplicacion de medidas. Se presentan tanto las areas de oportunidad, potenciales y medidas aplicadas y en aplicacion, asi como las inversiones requeridas y los periodos de recuperacion de las mismas.

  3. Electric energy saving in the cellulose and paper industry; Ahorro de energia electrica en la industria de celulosa y papel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-12-31

    This paper delineates the results of the demonstration project for electric energy saving, which is one of the twenty four projects in which the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) sponsors the diagnosis as well as the applied measures and the measures currently in application. Also the potential opportunity areas and the measures applied and in course of application, as well as the required investments and their recuperation periods. [Espanol] En este trabajo se describen los resultados del proyecto de demostracion de ahorro de energia electrica que es uno de los veinticuatro proyectos, en los que el Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) financia tanto el diagnostico como la aplicacion de medidas. Se presentan tanto las areas de oportunidad, potenciales y medidas aplicadas y en aplicacion, asi como las inversiones requeridas y los periodos de recuperacion de las mismas.

  4. Normalization of the energy efficiency in pumping systems; Normalizacion de eficiencia energetica en sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R.A.; Buendia Dominguez, E.H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE) has prepared the preliminary project of the norm of energetic efficiency for pumping systems, specifically for the agricultural sector. This document has complied with the necessary formalities for the issue of a norm and is about to be published as a Mexican Official Norm of energetic efficiency. In this paper mention is made of the results in the analysis of the pumping systems in operation, the energy saving, as well as the economic evaluation that sustain the norm project, indicating besides the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) ha elaborado el anteproyecto de norma de eficiencia energetica en sistemas de bombeo, especificamente para el sector agricola. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, y esta proximo a publicarse como norma oficial mexicana de eficiencia energetica. En el presente articulo se mencionan los resultados del analisis de los sistemas de bombeo en operacion, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  5. Normalization of the energy efficiency in pumping systems; Normalizacion de eficiencia energetica en sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R A; Buendia Dominguez, E H [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE) has prepared the preliminary project of the norm of energetic efficiency for pumping systems, specifically for the agricultural sector. This document has complied with the necessary formalities for the issue of a norm and is about to be published as a Mexican Official Norm of energetic efficiency. In this paper mention is made of the results in the analysis of the pumping systems in operation, the energy saving, as well as the economic evaluation that sustain the norm project, indicating besides the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) ha elaborado el anteproyecto de norma de eficiencia energetica en sistemas de bombeo, especificamente para el sector agricola. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, y esta proximo a publicarse como norma oficial mexicana de eficiencia energetica. En el presente articulo se mencionan los resultados del analisis de los sistemas de bombeo en operacion, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  6. Submersible pumps: Energetic efficiency norm; Bombas sumergibles: norma de eficiencia energetica

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R. A.; Buendia Dominguez, E. H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE), has prepared a preliminary project of the norm of energy efficiency for submersible pumps. This document has complied with the necessary formalities for the emission of the norm. This paper presents the results of the analysis of the submersible pumps, the energy savings, as well as the economic evaluation that sustains the norm project, additionally pointing out the environmental impact that will bring along the implantation of the same. [Espanol] El Instituto de Investigaciones Electricas (IIE), apoyando a la Comision Nacional para el Ahorro de Energia (CONAE), ha elaborado el anteproyecto de norma de eficiencia energetica para bombas sumergibles. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma. En el presente articulo se mencionan los resultados del analisis de las bombas sumergibles, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  7. Submersible pumps: Energetic efficiency norm; Bombas sumergibles: norma de eficiencia energetica

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R A; Buendia Dominguez, E H [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE), has prepared a preliminary project of the norm of energy efficiency for submersible pumps. This document has complied with the necessary formalities for the emission of the norm. This paper presents the results of the analysis of the submersible pumps, the energy savings, as well as the economic evaluation that sustains the norm project, additionally pointing out the environmental impact that will bring along the implantation of the same. [Espanol] El Instituto de Investigaciones Electricas (IIE), apoyando a la Comision Nacional para el Ahorro de Energia (CONAE), ha elaborado el anteproyecto de norma de eficiencia energetica para bombas sumergibles. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma. En el presente articulo se mencionan los resultados del analisis de las bombas sumergibles, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  8. Caracterización del sector cooperativo de ahorro y crédito en el Valle del Cauca

    Directory of Open Access Journals (Sweden)

    Ximena Sánchez Mayorga

    2008-01-01

    Full Text Available El artículo presenta una caracterización del sector cooperativo de ahorro y crédito en el Valle del Cauca, el cual es uno de los objetivos a desarrollar en el proyecto de investigación "Análisis del sector cooperativo de ahorro y crédito en el Valle del Cauca y propuesta de estrategia. Caso Cooperativa de Ahorro del Valle", del Grupo de Investigación Gestión y Productividad Contable. El estudio muestra la dinámica de crecimiento que ha tenido el sector cooperativo de ahorro y crédito en el Valle del Cauca en los últimos cinco años, aportando a la bancarización en Colombia; también se revisa el sector de economía solidaria en Colombia, presentando estadísticas que permiten visualizar lo que representa este sector en la economía del país. Se identifican en el Valle del Cauca las entidades dedicadas a la actividad de ahorro y crédito, planteándose las diferencias entre estas entidades y los establecimientos bancarios del sector financiero tradicional, resaltando el aporte de las cooperativas de ahorro y crédito a la estrategia del Gobierno Nacional definida como la banca de oportunidades1; puesto que en estas entidades hay igualdad social para sus asociados, logrando que un mayor número de personas accedan a los servicios financieros, aportando al desarrollo económico de las localidades donde funcionan.

  9. Determinantes del perfil de ahorro en Colombia : una estimación para hogares e individuos

    OpenAIRE

    Daza Báez, Nancy Aireth

    2011-01-01

    En este documento se presenta un análisis de los determinantes del perfil de ahorro para hogares e individuos con el objetivo de contrastar la Hipótesis de Ciclo de Vida, utilizando la metodología expuesta en Deaton y Paxson (2000a y 2000b) con datos de la Encuesta Nacional de Ingresos y Gastos (ENIG) para los periodos 1984-1985, 1994-1995 y 2006-2007. Se encontró que para el análisis por hogar no hay evidencia que determine el cumplimiento de la Hipótesis del Ciclo de Vida, mientras que para...

  10. El ahorro fiscal de las cooperativas en el impuesto sobre Sociedades en España

    OpenAIRE

    Herrero Blasco, Aurelio

    2015-01-01

    [ES] El objeto de este artículo es medir el ahorro fiscal que procede del Impuesto sobre Sociedades de las cooperativas en España para el período 1999-2009. La metodología utilizada ha sido un estudio longitudinal en el cual se ha analizado la recaudación total en España por tipos impositivos. Se ha analizado el Impuesto sobre Sociedades en general y posteriormente el Tipo Impositivo Efectivo (TIE) de las Sociedades Cooperativas. Los resultados más importantes son la constatación de diferenc...

  11. Supercritical waste oxidation pump investigation

    International Nuclear Information System (INIS)

    Thurston, G.; Garcia, K.

    1993-02-01

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications

  12. Aislamiento, bienestar y ahorro de energía

    Directory of Open Access Journals (Sweden)

    García Arroyo, A.

    1976-03-01

    Full Text Available The continous appearance of new materials, the general tendency towards lighter structural charges, the increased personal welfare levels, the extended use of mechanical equipments for environmental conditioning in most of the housings presently being constructed, and the incessant and considerable increase of the organic fuel costs have given rise to a new study, both in scope and precision, of the physical and construction basis of the fundamental problems of living spaces. Here the study of the installations deals with arrangements suitable for carrying out the architectural projects of the construction elements, in order to obtain their maximum efficiency, as regulators of the negative environmental influences. As already announced previously, this is the second of three articles published in three consecutive issues of INFORMES DE LA CONSTRUCCIÓN.La continua aparición de nuevos materiales, la tendencia general al aligeramiento de las cargas estructurales, el incremento de los niveles individuales de bienestar, la extensión de los equipos mecánicos de acondicionamiento ambiental a la mayoría de las viviendas actualmente en construcción, y el ininterrumpido y sustancial crecimiento en los costos de los combustibles orgánicos, han dado lugar al replanteamiento, en extensión y profundidad, de las bases físico-constructivas en las que descansa la problemática funcional de los recintos habitacionales. Se aborda aquí el estudio de las disposiciones constructivas idóneas para la práctica de los proyectos arquitecturales de los diferentes elementos constructivos, a fin de obtener su máxima funcionalidad como reguladores de las solicitaciones ambientales perturbadoras del bienestar. Como ya se advirtió, éste es el segundo artículo de la serie de tres que aparecen en 3 números sucesivos de INFORMES DE LA CONSTRUCCIÓN.

  13. 46 CFR 108.471 - Water pump.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  14. Aislamiento, bienestar y ahorro de energía

    Directory of Open Access Journals (Sweden)

    García Arroyo, Arturo

    1976-04-01

    Full Text Available The continuous appearance of new materials, the general tendency towards lighter structural loads, the increased personal welfare levels, the extended use of mechanical equipments for environmental conditioning in most of the housings presently being constructed, and the incessant and considerable increase of the organic fuel costs have given rise to a new study, both in scope and precision, of the physical and construction basis of the fundamental problems of living spaces. A comparative study is here carried out of the existing national and foreign Norms on the hygrothermal requirements that the members, and the spaces they form, have to comply with, so as to obtain comfort within the budget limits of an effective economy. As already mentioned, this is the last one of three articles published in consecutive issues of INFORMES DE LA CONSTRUCCIÓN.La continua aparición de nuevos materiales, la tendencia general al aligeramiento de las cargas estructurales, el incremento de los niveles individuales de bienestar, la extensión de los equipos mecánicos de acondicionamiento ambiental a la mayoría de las viviendas actualmente en construcción, y el ininterrumpido y sustancial crecimiento en los costos de los combustibles orgánicos, han dado lugar al replanteamiento, en extensión y profundidad, de las bases físico-constructivas en las que descansa la problemática funcional de los recintos habitacionales. Se aborda aquí el estudio comparado de la reglamentación existente, nacional y extranjera, de las necesidades higrotérmicas que han de cumplir los elementos y los recintos que éstos delimitan, para la consecución del confort, dentro de los presupuestos de una efectiva economía. Como ya se advirtió, éste es el último artículo de la serie de tres que han aparecido en números sucesivos de INFORMES DE LA CONSTRUCCIÓN.

  15. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  16. Aislamiento, bienestar y ahorro de energía

    Directory of Open Access Journals (Sweden)

    García Arroyo, A.

    1976-02-01

    Full Text Available The continous appearance of new materials, the general tendency towards lighter structural charges, the increased personal welfare levels, tile extended use of mechanical equipments for environmental conditioning in most of the housings presently being constructed, and the incessant and considerable increase of the organic fuel costs have given rise to a new study, both in scope and precision, of the physical and construction basis of the fundamental problems of living spaces. In addition to the financial and engineering aspects of the separate installations the problem is here approached through three different angles: I. Analysis of the thermophysical characteristics of the materials and structural elements that define and quantify the insulating capacity of these. II. Constructive arrangements suitable for carrying out the architectural projects of the construction elements, in order to obtain their maximum efficiency, as regulators of the negative environmental influences. III. A relative study of existing national and foreign regulations of the hygrothermal needs that the elements and structural spaces must meet to achieve the required comfort within the envisaged budget. Each of the above mentioned items will be dealt with in this Journal from this number onwards.La continua aparición de nuevos materiales, la tendencia general al aligeramiento de las cargas estructurales, el incremento de los niveles individuales de bienestar, la extensión de los equipos mecánicos de acondicionamiento ambiental a la mayoría de las viviendas actualmente en construcción, y e! ininterrumpido y sustancial crecimiento en los costos de los combustibles orgánicos, han dado lugar al replanteamiento, en extensión y profundidad, de las bases físico-constructivas en las que descansa la problemática funcional de los recintos habitacionales. Consideraciones financieras o de ingeniería de las instalaciones aparte, se aborda aquí el estudio del

  17. Las cooperativas de ahorro y crédito y la economía popular y solidaria, ante el derecho la veeduría ciudadana

    OpenAIRE

    Cisneros Bayas, Manuel Enrique

    2016-01-01

    En el año 2015 varias cooperativas de ahorro y crédito han entrado en liquidación, aproximadamente 75.000 clientes podrían ser perjudicados. La Superintendencia de Economía Popular y Solidaria (SEPS) anunció la liquidación de cinco cooperativas de ahorro y crédito, una en Riobamba (Chimborazo) y cuatro en Ambato (Tungurahua). La liquidación de la primera, la Cooperativa de Ahorro y Crédito Acción Rural con sede en Riobamba se dio debido a "pérdidas, incapacidad de cumplir sus obligaciones con...

  18. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  19. Equipment repair in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S

    1982-01-01

    Most equipment in Chinese coal mines consists of machinery and equipment produced in the 1950s; the efficiency of 4-62, CTD-57 and 70B/sub 2/ ventilators is 15% lower than that of new ones; that of SSM and AYaP pumps, 10% lower than of modern ones. Equipment renovation is done in three ways: replacing obsolete equipment with new equipment of the same type; improving the performance of existing equipment by introducing efficiency and reconstruction; and replacing obsolete equipment with advanced equipment. It is indicated that the second way, for example, replacement of 4-62 ventilator blades with a maximum efficiency of 73% by 4-72 ventilator blades raises its efficiency to 90%. Replacing the 8DA-8x3 water pump, having a maximum efficiency of 63%, with the 200D 43x3 pump with a maximum efficiency of 78%, enables an electricity savings of 7000 yuan per year, which exceeds all replacement costs (600 yuan). The need to improve equipment maintenance and preventive work to increase equipment service life and to introduce new techniques and efficiency is noted.

  20. Energy efficiency standardizing in vertical pumps; Normalizacion de eficiencia energetica en bombas verticales

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, Rosa Aracely; Buendia Dominguez, Eduardo H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The Instituto de Investigaciones Electricas (IIE) supporting the Comision Nacional para el Ahorro de Energia (CONAE) (National Commission for Energy Saving) developed the project of a standard on energy efficiency of vertical pumps, turbine type with external motor. This documents has fulfilled the necessary formalities for the issuing of a norm, being published the Mexican Official Norm (NOM-001-ENER-1995) on December 22, 1995. This article relates the results of the study for the elaboration of this norm, considering the energy saving, as well as the economic evaluation that supports the project of the norm, indicating also the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) elaboro el anteproyecto de norma de eficiencia energetica en bombas verticales tipo turbina con motor externo. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, habiendose publicado como Norma Oficial Mexicana (NOM-001-ENER-1995) el 22 de diciembre de 1995. En el presente articulo se mencionan los resultados del estudio para la realizacion de esta norma, considerando los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicando tambien el impacto ambiental que tendra su implantacion.

  1. Energy efficiency standardizing in vertical pumps; Normalizacion de eficiencia energetica en bombas verticales

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, Rosa Aracely; Buendia Dominguez, Eduardo H [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The Instituto de Investigaciones Electricas (IIE) supporting the Comision Nacional para el Ahorro de Energia (CONAE) (National Commission for Energy Saving) developed the project of a standard on energy efficiency of vertical pumps, turbine type with external motor. This documents has fulfilled the necessary formalities for the issuing of a norm, being published the Mexican Official Norm (NOM-001-ENER-1995) on December 22, 1995. This article relates the results of the study for the elaboration of this norm, considering the energy saving, as well as the economic evaluation that supports the project of the norm, indicating also the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) elaboro el anteproyecto de norma de eficiencia energetica en bombas verticales tipo turbina con motor externo. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, habiendose publicado como Norma Oficial Mexicana (NOM-001-ENER-1995) el 22 de diciembre de 1995. En el presente articulo se mencionan los resultados del estudio para la realizacion de esta norma, considerando los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicando tambien el impacto ambiental que tendra su implantacion.

  2. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  3. Energy conservation in ice manufacturing; Ahorro de energia en la fabricacion de hielo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    This paper shows the results of the energy diagnosis study for ice manufacturing industries. The identified opportunities for conservation and efficient use of energy have allowed the reduction of the electric bill, modernizing at the same time, its installations and addressing inherent aspects of the use of energy producing items; in which the estimated investments are recovered in its major part in a period of a year, the goodness of the investments propitiate the growth and competitiveness required in these days. [Espanol] En este documento se exponen los resultados del estudio del diagnostico energetico para industrias productoras de hielo. Las oportunidades de ahorro y uso eficiente de energia identificadas, han permitido reducir la facturacion energetica, a la par de modernizar sus instalaciones y atender aspectos inherentes al uso de energeticos; en lo cual las inversiones estimadas se recuperan en su mayoria en un ano, las bondades de las inversiones propician un crecimiento y competitividad requerida en estos dias.

  4. Carbon Bonds and the saving of energy; Bonos de carbono y el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Ramirez, Alejandro [NovaEnergia (Mexico)

    2005-07-01

    This document deals with the development of the carbon bond project, the energy saving and the entry into force of the Kyoto Protocol at a world-wide level. In this project Mexico opts for a development model in which the economic growth brakes ties with the discharge of greenhouse effect gases and in which the progress does not mean more damages to our planet. [Spanish] Este documento trata sobre el desarrollo del proyecto de bonos de carbono, ahorro de energia y la entrada en vigor del Protocolo de Kyoto a nivel mundial, en el cual Mexico opta por un modelo de desarrollo en el que el crecimiento economico esta desvinculado de la emision de gases de efecto invernadero y en donde el progreso no signifique mas danos a nuestro planeta.

  5. Energy conservation in ice manufacturing; Ahorro de energia en la fabricacion de hielo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    This paper shows the results of the energy diagnosis study for ice manufacturing industries. The identified opportunities for conservation and efficient use of energy have allowed the reduction of the electric bill, modernizing at the same time, its installations and addressing inherent aspects of the use of energy producing items; in which the estimated investments are recovered in its major part in a period of a year, the goodness of the investments propitiate the growth and competitiveness required in these days. [Espanol] En este documento se exponen los resultados del estudio del diagnostico energetico para industrias productoras de hielo. Las oportunidades de ahorro y uso eficiente de energia identificadas, han permitido reducir la facturacion energetica, a la par de modernizar sus instalaciones y atender aspectos inherentes al uso de energeticos; en lo cual las inversiones estimadas se recuperan en su mayoria en un ano, las bondades de las inversiones propician un crecimiento y competitividad requerida en estos dias.

  6. Energy saving program in an operating potable water and sanitation organism; Programa de ahorro de energia en un organismo operador de agua potable y saneamiento

    Energy Technology Data Exchange (ETDEWEB)

    Flores Cruz, Juan Jose [Fideicomiso para el Ahorro de la Energia Electrica, (Mexico)

    2001-03-01

    For the achievement of the objectives it was decided to use, among others, the following strategies: Personnel training, increase of the efficiency of the electromechanical equipment, study of Comision Federal de Electricidad (CFE) tariffs, correction of low power factors, increase of load factors, operation automate, regulation of the operation times, preventive maintenance of the equipment, establishment of technical standards, rational and efficient use of air conditioning equipment and illumination. So that these actions were applied in an easy and opportune form, it was established that within the structure of the General Coordination of Foreign Municipalities, the Program of Energy Saving depended directly of the Technical Management of CFE. In this way, the recommendations are first put under consideration of high-level officers, and then are lowered to the operative departments. [Spanish] Para el logro de los objetivos se acordo utilizar, entre otras, las siguientes estrategias: capacitacion del personal; aumentar la eficiencia de los equipos electromecanicos; estudio de tarifas de la Comision Federal de Electricidad (CFE); correccion de bajos factores de potencia; aumento de los factores de carga; automatizar la operacion; regular de los tiempos de operacion; mantenimiento preventivo a los equipos; establecimiento de normas tecnicas; uso racional y eficiente de aire acondicionado e iluminacion. Para que estas acciones se aplicaran en forma agil y oportuna, se establecio que dentro de la estructura de la Coordinacion General de Municipios Foraneos, el Programa de Ahorro de Energia dependiera directamente de la Gerencia Tecnica de la CRE. De esta forma, las recomendaciones primero se someten a consideracion de los funcionarios de alto nivel, y luego bajan a los departamentos operativos.

  7. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  8. Compact fluorescent lamps, innovation for electricity saving; Lamparas fluorescentes compactas, innovacion para el ahorro de electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, Fernando [Fideicomiso para el Ahorro de Energia Electrica (Mexico); Camacho P, Wendolin E; Villalobos Alarcon, German [Phillips Lighting Mexico (Mexico)

    2007-01-15

    An extremely important resource is electricity because it has provided illumination for homes, buildings and cities in the absence of natural light. Therefore, the human being is considering to save this valuable resource by using sophisticated light bulbs. At the end of the 70's the compact fluorescent lamps appeared. In this article we can disclose the advantages and disadvantages of this technology, and how some years later of its invention, those lamps satisfied the client expectations, due to its cost, electricity saving, longer lifetime, use possibilities, and technological improvements. We can also know how Federal Electricity Commission (CFE) and The Trust Fund for Electric Energy Savings (FIDE) supported a project to favor these lamps to be in the Mexican market. [Spanish] La electricidad es un recurso de suma importancia porque ha contribuido a la iluminacion de casas, edificios y ciudades, ante la ausencia de luz natural, es por ello que se ha buscado ahorrar este recurso tan preciado con el uso de lamparas sofisticadas. Una tecnologia que aparecio a finales de los anos 70 fueron las lamparas fluorescentes compactas. En este articulo encontramos sus ventajas y desventajas, y como despues de algunos anos de su creacion comenzaron a llenar las expectativas del cliente gracias a su costo, ahorro de electricidad, mayor tiempo de vida, posibilidades de aplicacion y mejoras tecnologicas. Asi mismo podemos conocer, el proyecto que se hizo para que esta tecnologia entrara al mercado mexicano, con el apoyo de la Comision Federal de Electricidad (CFE) y del Fideicomiso para el Ahorro de Energia Electrica (FIDE).

  9. Saving of electrical energy in educative institutions; Ahorro de energia electrica en instituciones educativas

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Medina, Gabino [Instituto Tecnologico y de Estudios Superiores de Monterrey Campus Estado de Mexico, (Mexico)

    2003-07-01

    The present work looks for integrating the actions of energy saving that can be applied in educative institutions, not concerning the level or size of the same ones. The actions go from questions of making aware the student population until those involved in the change in the operation, migration and implementation of technology. Without overlooking the formative aspect that the educative institutions have and the social commitment of these last ones. It is important that the saving measures have as mission to achieve a culture focussed to make efficient use of the resources, of energy as well as material. This culture must be born from the classrooms and must transform the way to be and act of the student community that will permeate itself with the society. Let us remember that actions are worth more than words, so the educative institutions must preach with the example. [Spanish] El presente trabajo busca integrar las acciones de ahorro de energia que pueden ser aplicadas en instituciones educativas, no importando el nivel o tamano de las mismas. Las acciones van desde cuestiones de concienciar a la poblacion estudiantil hasta las que involucran el cambio en la operacion, migracion e implementacion de tecnologia. Sin perder de vista el aspecto formativo que tienen las instituciones educativas y el compromiso social de estas ultimas. Es importante que las medidas de ahorro tengan como mision lograr una cultura enfocada a hacer uso eficiente de los recursos, tanto energeticos como materiales. Dicha cultura debe nacer desde las aulas y debe transformar la manera de ser y actuar, de la comunidad estudiantil que se permeara con la sociedad. Recordemos que las acciones valen mas que las palabras, asi que las instituciones educativas deben predicar con el ejemplo.

  10. Reactor coolant purification system circulation pumps (CUW pumps)

    International Nuclear Information System (INIS)

    Tsutsui, Toshiaki

    1979-01-01

    Coolant purification equipments for BWRs have been improved, and the high pressure purifying system has become the main type. The quantity of purifying treatment also changed to 2% of the flow rate of reactor feed water. As for the circulation pumps, canned motor pumps are adopted recently, and the improvements of reliability and safety are attempted. The impurities carried in by reactor feed water and the corrosion products generated in reactors and auxiliary equipments are activated by neutron irradiation or affect heat transfer adversely, adhering to fuel claddings are core structures. Therefore, a part of reactor coolant is led to the purification equipments, and returned to reactors after the impurities are eliminated perfectly. At the time of starting and stopping reactors, excess reactor water and the contaminated water from reactors are transferred to main condenser hot wells or waste treatment systems. Thus the prescribed water quality is maintained. The operational modes of and the requirements for the CUW pumps, the construction and the features of the canned motor type CUW pumps are explained. Recently, a pump operated for 11 months without any maintenance has been disassembled and inspected, but the wear of bearings has not been observed, and the high reliability of the pump has been proved. (Kako, I.)

  11. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  12. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  13. Electrokinetic pump

    Science.gov (United States)

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  14. Preventative maintenance plan for emergency pumping trailers

    International Nuclear Information System (INIS)

    Wiggins, D.D.

    1994-09-01

    The purpose/goal of this document is to identify the maintenance requirements and resources available to properly maintain the readiness and condition of the Emergency Pumping Equipment controlled by the Tank Waste Remediation System Tank Farms Plant Engineering and Tank Stabilization Operations. This equipment is intended to pump a single-shell tank (SST) that has been identified as an assumed leaking tank. The goal is to commence pumping (submersible or jet) as soon as safely possible after identifying a SST as an assumed leaking tank. Important information pertaining to the Emergency Pumping Equipment, Over-Ground Piping installation, and procedures is found in WHC-SD-WM-AP-005, ''Single Shell Tank Leak Emergency Pumping Guide.''

  15. Full-Scale Validation of a Comprehensive Criterion to Predict Fish-Friendliness of Pumps

    NARCIS (Netherlands)

    Krakers, L.A.; Kruyt, Nicolaas P.; Rutjes, H.A.

    2015-01-01

    Many pumping stations in drainage & irrigation applications are currently equipped with conventional (not fish friendly designed) pumps. Field tests have been performed [1] for several pump types of a certain size at certain pumping conditions to assess survival rates of fish passing through pumps.

  16. Pump cavitation and inducer design

    International Nuclear Information System (INIS)

    Heslenfeld, M.W.; Hes, M. de

    2002-01-01

    Details of past work on sodium pump development and cavitation studies executed mainly for SNR 300 were reported earlier. Among the requirements for large sodium pumps are long life (200000 hours up to 300000 hours) and small size of impeller and pump, fully meeting the process and design criteria. These criteria are the required 'Q, H, r characteristics' in combination with a low NPSH value and the avoidance of cavitation damage to the pump. The pump designer has to develop a sound hydraulic combination consisting of suction arrangement, impeller design and diffuser. On the other hand the designer is free to choose an optimal pump speed. The pump speed in its turn influences the rotor dynamic pump design and the pump drive. The introduction of the inducer as an integral part of the pump design is based on following advantages: no tip cavitation; (possible) cavitation bubbles move to the open centre due to centrifugal forces on the fluid; the head of the inducer improves the inlet conditions of the impeller. The aim of an inducer is the increase in the suction specific speed (SA value) of a pump whereby the inducer functions as a pressure source improving the impeller inlet conditions. With inducer-impeller combinations values up to SA=15000 are realistic. With the use of an inducer the overall pump sizes can be reduced with Ca. 30%. Pumps commonly available have SA values up to a maximum of ca. 10000. A development programme was executed for SNR 300 in order to reach an increase of the suction specific speed of the impeller from SA 8200 to SA 11000. Further studies to optimize pumps design for the follow up line introduced the 'inducer acting as a pre-impeller' development. This programme was executed in the period 1979-1981. At the FDO premises a scale 1 2.8 inducer impeller combination with a suction specific speed SA=15000 was developed, constructed and tested at the water test rig. This water test rig is equipped with a perspex pipe allowing also visualisation

  17. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  18. 46 CFR 109.329 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 109.329 Section 109.329 Shipping COAST GUARD... of Safety Equipment § 109.329 Fire pumps. The master or person in charge shall insure that at least one of the fire pumps required in § 108.415 is ready for use on the fire main system at all times. ...

  19. Double-shell tank emergency pumping guide

    International Nuclear Information System (INIS)

    BROWN, M.H.

    1999-01-01

    This Double-Shell Tank Emergency Pumping Guide provides the preplanning necessary to expeditiously remove any waste that may leak from the primary tank to the secondary tank for Hanfords 28 DSTs. The strategy is described, applicable emergency procedures are referenced, and transfer routes and pumping equipment for each tank are identified

  20. Double-shell tank emergency pumping guide

    International Nuclear Information System (INIS)

    BROWN, M.H.

    1999-01-01

    This Double-Shell Tank Emergency Pumping Guide provides the preplanning necessary to expeditiously remove any waste that may leak from the primary tank to the secondary tank for Hanford's 28 DSTS. The strategy is described, applicable emergency procedures are referenced, and transfer routes and pumping equipment for each tank are identified

  1. Reactor primary pumps dynamic balancing test

    International Nuclear Information System (INIS)

    Lu Qunxian

    2002-01-01

    Reactor primary Pump is the important equipment in the primary circuit, its working quality would directly influence the safety and operation of nuclear power plant. The author describes that the primary pump vibration status, vibration fault diagnosis and dynamic balancing process on site have been performed since commercial operation of DA YA BAY Nuclear Power plant

  2. Potential of energy saving with photovoltaic systems; Potencialidad de ahorro de energia con sistemas fotovoltaicos

    Energy Technology Data Exchange (ETDEWEB)

    Guzman S, Eusebio; Bratu S, Neagu [Universidad Autonoma Metropolitana, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents an approach on the application of photovoltaic systems in energy saving. The problem of the electric energy demand in the coming years is analyzed and its consequences on the environment and on the energy reserves of conventional sources. A model of the electric circuit equivalent to a photovoltaic cell illustrates the behavior of the photovoltaic cell in function of the climatological conditions. The former in order to show some of the limiting factors in this type of generator. Also, the evolution of the applications of the photovoltaic systems and its forecasting in the installed capacity in the next 20 years, is described. [Espanol] En este trabajo se presenta un enfoque de la aplicacion de los sistemas fotovoltaicos en el ahorro de energia. Se plantea el problema del crecimiento de la demanda energetica en los proximos anos y sus consecuencias sobre el medio ambiente y las reservas de energia por fuentes convencionales. Un modelo del circuito electrico equivalente de una celda fotovoltaica ilustra el comportamiento del generador fotovoltaico en funcion de las condiciones climatologicas. Lo anterior con el fin de mostrar algunas limitantes de este tipo de generador. Tambien se describe la evolucion de las aplicaciones de los sistemas fotovoltaicos y el pronostico de la potencia instalada en los proximos 20 anos.

  3. Remesas y Ahorro de los Migrantes Michoacanos radicados en EUA. Un Diagnóstico Preliminar

    Directory of Open Access Journals (Sweden)

    Jerjes Aguirre Ochoa

    2007-06-01

    Full Text Available El objetivo de este artículo es realizar un diagnostico del potencial productivo del ahorro migrante para el caso del estado de Michoacán. Los datos obtenidos muestran un perfil de Michoacano radicado en EUA con ingresos suficientes para enviar remesas familiares a México pero limitados para realizar inversiones mayores a 200 dólares mensuales en Michoacán. Dentro de esa limitación, de contar con capital, los michoacanos manifestaron una preferencia por invertir en México y específicamente en su comunidad de origen. La preferencia de inversión mas citada es la compra de una vivienda o reparación de la misma. Asimismo, la corrupción y la inseguridad son señaladas como obstáculos para la inversión en México. Finalmente, el alto porcentaje de migrantes indocumentados encontrados en la encuesta refleja los profundos impactos que una reforma migratoria en EUA puede tener en la dinámica económica del estado. La migración a EUA puede dejar de convertirse en la válvula de escape para la población michoacana que no encuentre oportunidades laborales en Michoacán sumiendo a la entidad en graves problemas económicos y sociales.

  4. Cálculo del ahorro de energía por menor fricción

    Directory of Open Access Journals (Sweden)

    Pedro Albarracín Aguillón

    2004-01-01

    Full Text Available En este artículo se expone como disminuir costos de operación (menor consumo de energía, costos de mantenimiento y pérdidas de producción de equipos, mediante el control de los diferentes fenómenos de la fricción en mecanismos lubricados. Para hacer esto posible es necesario conocer las condiciones criticas de trabajo de los mismos, a que tipo de lubricación corresponden, y que clase lubricante requiere, para así calcular los valores de los coeficientes de fricción de los lubricantes que se están empleando y compararlos con los de otros lubricantes que pueden dar lugar a ahorros de energía y mantenimiento. Además se presentan algunos ejemplos tomados de casos reales, que confirman que con una buena implementación de un programa de tribologia se obtienen resultados satisfactorios desde el punto de vista económico.

  5. Ahorro energético mediante estrategias de iluminación natural optimizadas

    Directory of Open Access Journals (Sweden)

    Puigdomènech Franquesa, Joan

    1986-04-01

    Full Text Available Electrical charges in buildings and specially in those of commercial use, can be diminished by means of natural lighting strategies. Taking the climate features of our country into consideration, it is necessary to prevent the inconveniences caused by an en erg y excess in summer, so solar Controls are needed. The only practical way to achieve the suitable balance between thermal and light needs, so as to get a monthly or annual energetic balance optimization, is to operate with the computer. A programme with such characteristics is described here. Its application gives important sarings in non renouvable energy savings.Mediante estrategias de iluminación natural es posible disminuir las cargas eléctricas de los edificios y en especial los de uso comercial. Dadas las características climáticas de nuestro país es necesario prever los inconvenientes de un exceso de energía en verano, para lo cual es preciso disponer de controles solares. Encontrar el correcto equilibrio entre las necesidades térmicas y lumínicas en base a la optimización del balance energético mensual o anual es únicamente factible mediante el uso del ordenador. Un programa que responde a estas características es descrito en el presente trabajo, obteniéndose con su aplicación importantes ahorros en el consumo de energías no renovables.

  6. Potential of energy saving with photovoltaic systems; Potencialidad de ahorro de energia con sistemas fotovoltaicos

    Energy Technology Data Exchange (ETDEWEB)

    Guzman S, Eusebio; Bratu S, Neagu [Universidad Autonoma Metropolitana, Mexico, D. F. (Mexico)

    1999-12-31

    This paper presents an approach on the application of photovoltaic systems in energy saving. The problem of the electric energy demand in the coming years is analyzed and its consequences on the environment and on the energy reserves of conventional sources. A model of the electric circuit equivalent to a photovoltaic cell illustrates the behavior of the photovoltaic cell in function of the climatological conditions. The former in order to show some of the limiting factors in this type of generator. Also, the evolution of the applications of the photovoltaic systems and its forecasting in the installed capacity in the next 20 years, is described. [Espanol] En este trabajo se presenta un enfoque de la aplicacion de los sistemas fotovoltaicos en el ahorro de energia. Se plantea el problema del crecimiento de la demanda energetica en los proximos anos y sus consecuencias sobre el medio ambiente y las reservas de energia por fuentes convencionales. Un modelo del circuito electrico equivalente de una celda fotovoltaica ilustra el comportamiento del generador fotovoltaico en funcion de las condiciones climatologicas. Lo anterior con el fin de mostrar algunas limitantes de este tipo de generador. Tambien se describe la evolucion de las aplicaciones de los sistemas fotovoltaicos y el pronostico de la potencia instalada en los proximos 20 anos.

  7. Equipment for liquid metal pressure measurement

    International Nuclear Information System (INIS)

    Jung, J.

    1977-01-01

    Equipment is proposed for measuring liquid metal pressure in piping or a tank. An auxiliary piping is connected to the piping or tank at the measuring point. The auxiliary piping transports liquid metal to a container by means of an electromagnetic pump. The piping also houses an electromagnetic flow ratemeter connected to an electric comparator. The comparator and the electromagnetic pump are connected to the pump output generator. (Z.M.)

  8. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  9. Fluidic pumps

    International Nuclear Information System (INIS)

    Priestman, G.H.

    1990-01-01

    A fluidic pump has primary and secondary vessels connected by a pipe, a displacement vessel having liquid to be delivered through a pipe via a rectifier provided with a feed tank. A drive unit delivers pressure fluid to a line to raise liquid and compress trapped gas or liquid in the space, including the pipe between the liquids in the two vessels and thus drive liquid out of the displacement vessel. The driving gas is therefore separated by the barrier liquid and the trapped gas or liquid from the liquid to be pumped which liquid could be e.g. radioactive. (author)

  10. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  11. Peristaltic pumps for waste disposal

    International Nuclear Information System (INIS)

    Griffith, G.W.

    1992-09-01

    Laboratory robots are capable of generating large volumes of hazardous liquid wastes when they are used to perform chemical analyses of metal finishing solutions. A robot at Allied-Signal Inc., Kansas City Division, generates 30 gallons of acid waste each month. This waste contains mineral acids, heavy metals, metal fluorides, and other materials. The waste must be contained in special drums that are closed to the atmosphere. The initial disposal method was to have the robot pour the waste into a collecting funnel, which contained a liquid-sensing valve to admit the waste into the drum. Spills were inevitable, splashing occurred, and the special valve often didn't work well. The device also occupied a large amount of premium bench space. Peristaltic pumps are made to handle hazardous liquids quickly and efficiently. A variable-speed pump, equipped with a quick-loading pump head, was mounted below the robot bench near the waste barrel. The pump inlet tube was mounted above the bench within easy reach of the robot, while the outlet tube was connected directly to the barrel. During operation, the robot brings the waste liquid up to the pump inlet tube and activates the pump. When the waste has been removed, the pump stops. The procedure is quick, simple, inexpensive, safe, and reliable

  12. 46 CFR 154.534 - Cargo pumps and cargo compressors.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pumps and cargo compressors. 154.534 Section 154.534 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Equipment Cargo and Process Piping Systems § 154.534 Cargo pumps and cargo compressors. Cargo pumps and...

  13. 33 CFR 183.566 - Fuel pumps: Placement.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel pumps: Placement. 183.566...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.566 Fuel pumps: Placement. Each fuel pump must be on the engine it serves or within 12 inches of the engine, unless it is a...

  14. 46 CFR 105.35-5 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 105.35-5 Section 105.35-5 Shipping COAST... VESSELS DISPENSING PETROLEUM PRODUCTS Fire Extinguishing Equipment § 105.35-5 Fire pumps. (a) All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per...

  15. 46 CFR 76.25-15 - Pumps and water supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Pumps and water supply. 76.25-15 Section 76.25-15... EQUIPMENT Automatic Sprinkling System, Details § 76.25-15 Pumps and water supply. (a) An automatically controlled pump shall be provided to supply the sprinkling system and shall be used for no other purpose. The...

  16. Mixer pump test plan for double shell tank AZ-101

    International Nuclear Information System (INIS)

    STAEHR, T.W.

    1999-01-01

    Mixer pump systems have been chosen as the method for retrieval of tank wastes contained in double shell tanks at Hanford. This document describes the plan for testing and demonstrating the ability of two 300 hp mixer pumps to mobilize waste in tank AZ-101. The mixer pumps, equipment and instrumentation to monitor the test were installed by Project W-151

  17. Aplicación de la Contabilidad de Costos en las Cajas Rurales de Ahorro y Crédito en el Perú, Arequipa - 2013

    OpenAIRE

    Pacheco Zegarra, Edward Víctor

    2017-01-01

    El presente trabajo de investigación busca determinar el grado de aplicación de la contabilidad de costos en las Cajas Rurales de Ahorro y Crédito en el Perú. ENUNCIADO “APLICACIÓN DE LA CONTABILIDAD DE COSTOS EN LA CAJAS RURALES DE AHORRO Y CRÉDITO EN EL PERÚ, AREQUIPA – 2013” La variable a investigar fue la aplicación de la contabilidad de costos cuyos indicadores son las generalidades de la aplicación de la contabilidad de costos, objetivos de la contabilidad de costos...

  18. Experiences of energy saving and co-generation projects; Experiencias de proyectos de ahorro de energia y cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Barajas, Alberto [Heat and Power Systems, S.A. de C.V., Mexico D.F. (Mexico)

    2005-07-01

    In this document are presented the successful projects of energy saving and co-generation that Heat and Power Systems, S.A. de C.V. has made in diverse industries. The investment recovery periods have been smaller to 18 months. The projects have been made for different companies within Mexican Republic. [Spanish] Se presentan los casos exitosos de proyectos de ahorro de energia y cogeneracion que Heat and Power Systems, S.A. de C.V. ha realizado en diversas industrias cuyo periodo de recuperacion de la inversion han sido menores a 18 meses. Los proyectos han sido realizados para distintas empresas dentro de la Republica Mexicana.

  19. Social responsibility and social security: The foundation of caja de pensiones para la vejez y de ahorros

    OpenAIRE

    Argandoña, Antonio; Moreno, Carlos M.; Sola, Joan M.

    2009-01-01

    The concept of Corporate Social Responsibility (CSR) is not new. Over the course of time, many entrepreneurs have created and developed companies, with a strong sense of ethical and social responsibility. This paper presents an example of how CSR was conceived and put into practice when Caja de Pensiones para la Vejez y de Ahorros was created in Barcelona in 1905, following the life and ideas of its founder, Francesc Moragas, a lawyer with a deep commitment to social action and a successful c...

  20. Ahorro de consumo de agua, aplicando técnicas de riego en jardines de la UNAC

    OpenAIRE

    Sánchez Hernández, Jaime Eloy

    2013-01-01

    La implementación del Proyecto "AHORRO DE CONSUMO DE AGUA, APLICANDO TECNICAS DE RIEGO EN JARDINES DE LA UNAC, con un sistema tecnificado de riego, específicamente por aspersión, se lograría ahorrar agua aproximadamente en un 50%. Además de personal de jardinería provista de mangueras (sistema de inundación) se dedicarían a otras labores que mejoren los jardines de la UNAC. Como corolario se tiene que no solo se ahorraría agua (pago de consumo a la empresa SEDAPAL), sino que al personal se...

  1. El Ahorro de los hogares colombianos: un análisis a partir de las encuestas de ingresos y gastos

    OpenAIRE

    Castañeda Cordy, Alberto

    2004-01-01

    Consultable des del TDX Títol obtingut de la portada digitalitzada En Colombia el seguimiento a la evolución del ahorro privado y de las variables que lo determinan se ha realizado a partir de la información agregada de las cuentas nacionales. No existe aproximación alguna a partir de datos individuales que consideren el influjo de las características socioeconómicas de las familias sobre esa variable. Esto obedece, en gran parte, a la ausencia de datos de encuestas que sigan la evoluci...

  2. El ahorro de los hogares colombianos: un analisis a partir de las encuestas de ingresos y gastos

    OpenAIRE

    Castañeda Cordy, Alberto

    2003-01-01

    En Colombia el seguimiento a la evolución del ahorro privado y de las variables que lo determinan se ha realizado a partir de la información agregada de las cuentas nacionales. No existe aproximación alguna a partir de datos individuales que consideren el influjo de las características socioeconómicas de las familias sobre esa variable. Esto obedece, en gran parte, a la ausencia de datos de encuestas que sigan la evolución de los ingresos y los consumos de los hogares.Mientras la información ...

  3. Determinantes del isomorfismo institucional de las sociedades cooperativas de ahorro y préstamos en México

    OpenAIRE

    Lara Gómez, Graciela; Pérez Sosa, Felipe A.

    2015-01-01

    El propósito del presente trabajo es establecer si las sociedades cooperativas de ahorro y préstamo se hacen isomorfas a la banca formal en México; debido a que tales entidades tradicionalmente han operado en un entorno de informalidad, pero últimamente han transitado hacia la formalización como consecuencia de las exigencias legales impuestas por entidades regulatorias. Para este fin, el presente estudio se llevó a cabo con una orientación metodológica mixta, en la que los resultados obtenid...

  4. Energy saving in the sugar cane agroindustry; Ahorro de energia en la agroindustria azucarera canera

    Energy Technology Data Exchange (ETDEWEB)

    Zedillo Ponce de Leon, Luis [Grupo de paises Latinoamericanos y del Caribe exportadores de azucar (Mexico)

    1996-07-01

    The traditional sugar mill is inefficient from the energy point of view. Most of the sugar mills were designed to use all the available bagasse, due to the risk of spontaneous ignition and environmental pollution. Consequently, the steam generators, the turbines and other components were designed to work with low efficiencies. Each ton of sugar produced generates a power potential equivalent to four to six oil barrels (bagasse and residues). That is to say, a sugar mill is capable of producing 500 ton/day of sugar, equivalent to an oil well of 2000 to 3000 barrels/day and one thermoelectric power plant of 15,000 kW. Under this context an analysis is made of the sugar mills in Latin America and the Caribbean as one of the ways of increasing their efficiency and obtain great energy savings. As far as steam generation the appropriate use of energy is dictated by the boilers' efficiency. [Spanish] El ingenio azucarero tradicional es ineficiente desde el punto de vista energetico. La mayoria de los ingenios azucareros se disenaron para usar todo el bagazo disponible, debido al riesgo de ignicion espontanea y contaminacion. En consecuencia, los generadores de vapor, las turbinas y demas componentes fueron disenados para trabajar con bajas eficiencias. Cada tonelada de azucar producida genera una potencialidad energetica equivalente de cuatro a seis barriles de petroleo (bagazo y residuos). Es decir, un ingenio capaz de producir 500 ton/dia de azucar equivalente a un pozo de petroleo de 2000 a 3000 barriles/dia y una termoelectrica de 15000 kW. Bajo este contexto se hace un analisis del ingenio azucarero en Latinoamerica y el Caribe como una de las vias para incrementar su eficiencia y lograr grandes ahorros en la energia. En cuanto a generacion de vapor se refiere, el buen uso de la energia viene expresado por la eficiencia de las calderas.

  5. Replacement Saltwell Pumping System Document Bibliography

    International Nuclear Information System (INIS)

    BELLOMY, J.R.

    2000-01-01

    This document bibliography is prepared to identify engineering documentation developed during the design of the Replacement Saltwell Pumping System. The bibliography includes all engineering supporting documents and correspondence prepared prior to the deployment of the system in the field. All documents referenced are available electronically through the Records Management Information System (RMIS). Major components of the Replacement Saltwell Pumping System include the Sundyne Canned Motor Pump, the Water Filter Skid, the Injection Water Skid and the Backflow Preventer Assembly. Drawing H-14-104498 provides an index of drawings (fabrication details, PandIDs, etc.) prepared to support development of the Replacement Saltwell Pumping System. Specific information pertaining to new equipment can be found in Certified Vendor Information (CVI) File 50124. This CVI file has been established specifically for new equipment associated with the Replacement Saltwell Pumping System

  6. Solar Pump

    Science.gov (United States)

    Pique, Charles

    1987-01-01

    Proposed pump moves liquid by action of bubbles formed by heat of sun. Tube of liquid having boiling point of 100 to 200 degrees F placed at focal axis of cylindrical reflector. Concentrated sunlight boils liquid at focus, and bubbles of vapor rise in tube, carrying liquid along with them. Pressure difference in hot tube sufficient to produce flow in large loop. Used with conventional flat solar heating panel in completely solar-powered heat-storage system.

  7. 46 CFR 76.10-5 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Fire pumps. 76.10-5 Section 76.10-5 Shipping COAST GUARD..., Details § 76.10-5 Fire pumps. (a) Vessels shall be equipped with independently driven fire pumps in accordance with table 76.10-5(a). Table 76.10-5(a) Gross tons Over Not over Minimum number of pumps...

  8. Centrifugal Pump Monitoring and Determination of Pump Characteristic Curves Using Experimental and Analytical Solutions

    Directory of Open Access Journals (Sweden)

    Marius Stan

    2018-02-01

    Full Text Available Centrifugal pumps are widely used in the industry, especially in the oil and gas sector for fluids transport. Classically, these are designed to transfer single phase fluids (e.g., water at high flow rates and relatively low pressures when compared with other pump types. As part of their constructive feature, centrifugal pumps rely on seals to prevent air entrapment into the rotor during its normal operation. Although this is a constructive feature, water should pass through the pump inlet even when the inlet manifold is damaged. Modern pumps are integrated in pumping units which consist of a drive (normally electric motor, a transmission (when needed, an electronic package (for monitoring and control, and the pump itself. The unit also has intake and outlet manifolds equipped with valves. Modern systems also include electronic components to measure and monitor pump working parameters such as pressure, temperature, etc. Equipment monitoring devices (vibration sensors, microphones are installed on modern pumping units to help users evaluate the state of the machinery and detect deviations from the normal working condition. This paper addresses the influence of air-water two-phase mixture on the characteristic curve of a centrifugal pump; pump vibration in operation at various flow rates under these conditions; the possibilities of using the results of experimental investigations in the numerical simulations for design and training purposes, and the possibility of using vibration and sound analysis to detect changes in the equipment working condition. Conclusions show that vibration analysis provides accurate information about the pump’s functional state and the pumping process. Moreover, the acoustic emission also enables the evaluation of the pump status, but needs further improvements to better capture and isolate the usable sounds from the environment.

  9. Some problems in exploitation of deep-pumping wells in Tatarian oil fields

    Energy Technology Data Exchange (ETDEWEB)

    Ishemguzhin, S B

    1970-01-01

    Difficulty has been experienced in pumping paraffinic oil with rod pumps. The rods have scrapers to remove paraffin from tubing walls, however this method does not work well. In an effort to improve pumping efficiency, gas anchors of various types were tried. Best results were obtained when the pumps, equipped with gas anchors, were placed about 300 m under the dynamic liquid level, and separated gas was steadily removed through the annulus. With this arrangement, more complete filling of the pump was achieved. Experience has shown that with separate production of gas from wells, the useful stroke of the pump plunger is increased as well as productivity of deep-pumping equipment.

  10. Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Garibay Mendoza, V. [Lumisistemas, departamento de aseguramineto de calidad, Naucalpan (Mexico); Hernandez Bernal, J. M. [UNICORP, Mexico, D. F. (Mexico)

    1995-12-31

    In a lighting system the discharge lamps (fluorescent and high intensity discharge (HID)), ballast and controls are generating elements of harmonics. As a consequence of the tendency of saving energy, the use of electronic ballasts and controls that integrate dimmers, daylight and present sensors has increased in order to optimize the energy use. This paper presents the harmonics generation resulting from the fluorescent lamps operating different electronic ballasts as well as their electronic controls. Likewise, are also shown the effects caused by generation of harmonics components by the lighting system in the electric system that go from the voltage and current distortion, the presence of currents in the neutral conductor in balanced systems to the repercussions in the metering equipment such as watthour meters and the effects the lighting equipment suffer due to the presence of harmonics, such as the power factor decrease in ballasts that are of high power factor and the temperature increment in the magnetic type ballasts. [Espanol] Dentro de un sistema de iluminacion, las lamparas de descarga (fluorescentes y alta intensidad de descarga {sup H}ID{sup )}, balastros y los controles son elementos generadores de armonicas. A consecuencia de la tendencia al ahorro de energia se ha incrementado el uso de balastros electronicos y controles que integran atenuadores de luz (dimmers), sensores de luz natural y de presencia con el fin de optimizar el uso de la energia. Este trabajo presenta los resultados de generacion de armonicas para lamparas fluorescentes, operando diferentes balastros electronicos asi como con controles electronicos. Asi mismo son presentados los efectos causados por la generacion de componentes armonicas por el sistema de iluminacion dentro del sistema electrico que van desde la distorsion en voltaje y corriente, la presencia de corrientes dentro del conductor neutro en sistemas balanceados, asi como la repercusion en los equipos de medicion tales

  11. Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Garibay Mendoza, V [Lumisistemas, departamento de aseguramineto de calidad, Naucalpan (Mexico); Hernandez Bernal, J M [UNICORP, Mexico, D. F. (Mexico)

    1996-12-31

    In a lighting system the discharge lamps (fluorescent and high intensity discharge (HID)), ballast and controls are generating elements of harmonics. As a consequence of the tendency of saving energy, the use of electronic ballasts and controls that integrate dimmers, daylight and present sensors has increased in order to optimize the energy use. This paper presents the harmonics generation resulting from the fluorescent lamps operating different electronic ballasts as well as their electronic controls. Likewise, are also shown the effects caused by generation of harmonics components by the lighting system in the electric system that go from the voltage and current distortion, the presence of currents in the neutral conductor in balanced systems to the repercussions in the metering equipment such as watthour meters and the effects the lighting equipment suffer due to the presence of harmonics, such as the power factor decrease in ballasts that are of high power factor and the temperature increment in the magnetic type ballasts. [Espanol] Dentro de un sistema de iluminacion, las lamparas de descarga (fluorescentes y alta intensidad de descarga {sup H}ID{sup )}, balastros y los controles son elementos generadores de armonicas. A consecuencia de la tendencia al ahorro de energia se ha incrementado el uso de balastros electronicos y controles que integran atenuadores de luz (dimmers), sensores de luz natural y de presencia con el fin de optimizar el uso de la energia. Este trabajo presenta los resultados de generacion de armonicas para lamparas fluorescentes, operando diferentes balastros electronicos asi como con controles electronicos. Asi mismo son presentados los efectos causados por la generacion de componentes armonicas por el sistema de iluminacion dentro del sistema electrico que van desde la distorsion en voltaje y corriente, la presencia de corrientes dentro del conductor neutro en sistemas balanceados, asi como la repercusion en los equipos de medicion tales

  12. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  13. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  14. Daylight-saving time: Consumption and demand saving and pollutants emission reduction; El cambio de horario de verano: Ahorros en consumo y demanda, y reduccion de contaminantes

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Gaudencio; Diaz, Rodrigo; Fiscal, Raul; Alquicira, Claudia; Martinez, Serafin; Maqueda, Martin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    This paper presents some of the saving obtained in demand and in fuels with the daylight-saving time, as well as the main aspects considered to make an evaluation of it. [Espanol] Se presentan los ahorros obtenidos en consumo, demanda y combustibles con el cambio de horario de verano, asi como los principales aspectos considerados para efectuar la evaluacion de los mismos.

  15. Daylight-saving time: Consumption and demand saving and pollutants emission reduction; El cambio de horario de verano: Ahorros en consumo y demanda, y reduccion de contaminantes

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Gaudencio; Diaz, Rodrigo; Fiscal, Raul; Alquicira, Claudia; Martinez, Serafin; Maqueda, Martin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    This paper presents some of the saving obtained in demand and in fuels with the daylight-saving time, as well as the main aspects considered to make an evaluation of it. [Espanol] Se presentan los ahorros obtenidos en consumo, demanda y combustibles con el cambio de horario de verano, asi como los principales aspectos considerados para efectuar la evaluacion de los mismos.

  16. Píldora de Crecimiento Económico: Modelos de crecimiento económico con tasas de ahorro constantes

    OpenAIRE

    López Díaz, Julio

    2015-01-01

    Claves para obtener, con carácter genérico, la ecuación fundamental de crecimiento en un modelo con tasa de ahorro constante. Departamento de Fundamentos del Análisis Económico e Historia e Instituciones Económicas

  17. Experience with rotating equipment in FBTR

    International Nuclear Information System (INIS)

    Babu, A.; Subramanian, K.G.; Selvam, B.

    2006-01-01

    Fast breeder test reactor (FBTR) is a 40MWth sodium cooled PuC-UC fuelled fast breeder reactor located at Kalpakkam, Tamilnadu. FBTR has a variety of mechanical and electrical equipment comprising of single stage and multi stage water pumps, sodium pumps, compressors, Chiller units, Diesel Generator sets, vacuum pumps, ventilation fans, Turbo generator etc. The degree and extent of maintenance on these equipment are decided based on nuclear safety, station technical specification requirements, design criteria and operating philosophy. The variety and complexity of the equipment in FBTR demands various maintenance strategies (preventive, predictive, proactive etc.) for their upkeep. This paper discusses the performance of all mechanical and electrical equipment in FBTR, measures taken for their upkeep, major modifications done to prevent recurring failures, condition monitoring programme implemented, Maintenance Management and Information System developed for data acquisition and dissemination, etc. (author)

  18. Pitfalls of Insulin Pump Clocks

    Science.gov (United States)

    Reed, Amy J.

    2014-01-01

    The objective was to raise awareness about the importance of ensuring that insulin pumps internal clocks are set up correctly at all times. This is a very important safety issue because all commercially available insulin pumps are not GPS-enabled (though this is controversial), nor equipped with automatically adjusting internal clocks. Special attention is paid to how basal and bolus dose errors can be introduced by daylight savings time changes, travel across time zones, and am-pm clock errors. Correct setting of insulin pump internal clock is crucial for appropriate insulin delivery. A comprehensive literature review is provided, as are illustrative cases. Incorrect setting can potentially result in incorrect insulin delivery, with potential harmful consequences, if too much or too little insulin is delivered. Daylight saving time changes may not significantly affect basal insulin delivery, given the triviality of the time difference. However, bolus insulin doses can be dramatically affected. Such problems may occur when pump wearers have large variations in their insulin to carb ratio, especially if they forget to change their pump clock in the spring. More worrisome than daylight saving time change is the am-pm clock setting. If this setting is set up incorrectly, both basal rates and bolus doses will be affected. Appropriate insulin delivery through insulin pumps requires correct correlation between dose settings and internal clock time settings. Because insulin pumps are not GPS-enabled or automatically time-adjusting, extra caution should be practiced by patients to ensure correct time settings at all times. Clinicians and diabetes educators should verify the date/time of insulin pumps during patients’ visits, and should remind their patients to always verify these settings. PMID:25355713

  19. Fault detection in the electrical equipment of the artificial system, used for the oil production in marine platforms; Deteccion de fallas en los equipos electricos del sistema artificial, utilizado para la produccion de petroleo en plataformas marinas

    Energy Technology Data Exchange (ETDEWEB)

    Vargas H, Vicente; Rosales S, Inocente [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Pimentel M, Jorge [Petroleos Mexicanos (Mexico)

    2007-07-01

    At present, PEMEX is using new artificial pumping systems for the production of oil, specifically the Electro Centrifugal Pumping system (ECP). Nevertheless, during the operation of the (ECP) system problems by the failure of their electrical components have appeared, mainly of the equipment installed within the well. The faults have resulted in an increased cost for the diminution in the production and the maintenance cost of the remedial work. The maintenance personnel have procedures to perform verification tests of the conditions of the bottom electrical equipment. But, in the case of an electrical failure of the equipment, its location cannot be determined, since they are installed at 3,600 m from the production wellhead. In accordance with the former, the Instituto de Investigaciones Electricas proposed the application of the reflectometry technique in the time domain, to complement the maintenance procedures. This technique is a very useful diagnosis tool of the electrical equipment, which helps in the decision making of the maneuvers of preventive and corrective maintenance to be followed, with the consequent saving of resources. [Spanish] Actualmente, PEMEX esta utilizando nuevos sistemas artificiales de bombeo para la produccion de petroleo, en especifico el Sistema de Bombeo Electrocentrifugo (BEC). Sin embargo, durante la operacion del Sistema BEC se han presentado problemas por la falla de sus componentes electricos, sobre todo del equipo instalado dentro del pozo. Las fallas han resultado con un costo elevado por la disminucion en la produccion y por los trabajos de mantenimiento correctivo. El personal de mantenimiento cuenta con procedimientos para realizar pruebas de verificacion del estado de los equipos electricos de fondo. Pero, en el caso de una falla electrica de los equipos, no se puede determinar su ubicacion, dado que se instalan a 3,600 m del cabezal del pozo de produccion. De acuerdo con lo anterior, el Instituto de Investigaciones

  20. Pressure surges generated by the polling out of pumping equipment in conduction by pressure. Application of a real case; Transitorios hidraulicos generados por arranque de equipos de bombeo en conducciones a presion. Aplicacion a un caso real

    Energy Technology Data Exchange (ETDEWEB)

    Carmona-Perales, L. G.; Carmona-Perales, R. B. [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2000-12-01

    Water closed conduits are commonly designed with special attention paid to pressure surges due to pumping failures. In some particular cases, such at the Rio Yaque-Guaymas water pipeline system, pressure surges due to pumping start up are as high and dangerous as those produced by pumping failures. New subroutines were thus developed and included in the Closed Conduit Flow Transient Model developed by the Instituto de Ingenieria of the Universidad Nacional Autonoma de Mexico. This paper presents the mathematical model and its numerical solution using the Method of Characteristics and the Newton-Raphson Method. With the new modelling system it is possible to evaluate the pressure fluctuation time series due to start up at any pumping system. Using this new system a reliable explanation of bursts at the Rio Yaqui-Guaymas pipeline system could be set forth. [Spanish] Al disenar conducciones a presion, es comun que se presente especial atencion a los transitorios hidraulicos generados por paros de emergencia de los equipos de bombeo. En el acueducto rio Yaqui-Guaymas, Sonora, Mexico, los transitorios generados al poner en marcha los equipos de bombeo son tan importantes como los productos por disparo de bombas. En el Instituto de Ingenieria de la UNAM, se desarrollo e implanto en un programa de simulacion de transitorios hidraulicos en tuberias a presion una subrutina para simular el arranque de equipos de bombeo. El modelo matematico esta formado por el conjunto de ecuaciones dinamica y de continuidad, asi como la condicion de frontera que describe el arranque de las bombas. Se rescriben las ecuaciones dinamicas y de continuidad, con el metodo de las caracteristicas y se plantea un sistema de ecuaciones no lineales, el cual se resuelve con el metodo de Newton-Raphson. La simulacion del arranque de las bombas del acueducto en estudio, arroja valores de las cargas piezom ricas maximas y minimas mayores que la resistencia de la tuberia y menores que la topografia del

  1. Pressure surge generated by start up of pumping equipment in pipes to pressure. Application to a real case; Transitorios hidraulicos generados por arranque de equipo de bombeo en conducciones a presion. Aplicacion a un caso real

    Energy Technology Data Exchange (ETDEWEB)

    Carmona Paredes, L.G.; Carmona Paredes, R.B. [Instituto de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2000-12-01

    Water closed conduits are commonly designed with special attention paid to pressure surges due to pumping failures. In some particular cases, such at the Rio Yaqui-Guaymas water pipeline system, pressure surges due to pumping start ups are as high and dangerous as those produced by pumping failures. New subroutines were thus developed and included in the Closed Conduit Flow Transient Model developed by the Instituto de Ingenieria of the Universidad Nacional Autonoma de Mexico. This paper presents the mathematical model and its numerical solution using the Method of Characteristics and the Newton-Raphson Method. With the new modeling system it is possible to evaluate the pressure fluctuation time series due to start up at any pumping system. Using this new system a reliable explanation of bursts at the Rio Yaqui-Guaymas system could be set forth. [Spanish] Al disenar conducciones a presion, es comun que se preste especial atencion a los transitorios hidraulicos generados por paros de emergencia de los equipos de bombeo. En el acueducto rio Yaqui-Guaymas, Sonora, Mexico, los transitorios generados al poner en marcha los equipos de bombeo son tan importantes como los producidos por disparo de bombas. En el Instituto de Ingenieria de la UNAM, se desarrollo e implanto en su programa de simulacion de transitorios hidraulicos en tuberias a presion una subrutina para simular el arranque de equipos de bombeo. El modelo matematico esta formado por el conjunto de ecuaciones dinamica y de continuidad, asi como la condicion de frontera que describe el arranque de las bombas. Se reescriben las ecuaciones dinamica y de continuidad, con el metodo de las caracteristicas y se plantea un sistema de ecuaciones no lineales, el cual se resuelve con el metodo de las caracteristicas y se plantea un sistema de ecuaciones no lineales, el cual se resuelve con el metodo de newton-raphson. La simulacion del arranque de las bombas del acueducto en estudio, arroja valores de las cargas

  2. Internal pump

    International Nuclear Information System (INIS)

    Kushima, Jun; Hayashi, Youjiro; Ueda, Masayuki.

    1997-01-01

    The present invention relates to an internal pump. A water hole allowing communication between internal and external circumferences of a stretch tube is provided at the portion of the stretch tube corresponding to a position where an end face of a nozzle portion of a motor case and an end face of a diffuser are joined with each other so that hot filtered water inside a pressure container which has entered from where the end face of the nozzle portion of the motor case and the end face of the diffuser are joined with each other is combined with the purged water so that it can be sent back to the pressure container again. (author) figs

  3. Heat pumps in western Switzerland

    International Nuclear Information System (INIS)

    Freymond, A.

    2003-01-01

    The past ten years have seen an extraordinary expansion of heat-pump market figures in the western (French speaking) part of Switzerland. Today, more than 14,000 units are in operation. This corresponds to about 18% of all the machines installed in the whole country, compared to only 10 to 12% ten years ago. This success illustrates the considerable know-how accumulated by the leading trade and industry during these years. It is also due to the promotional program 'Energy 2000' of the Swiss Federal Department of Energy that included the heat pump as a renewable energy source. Already in 1986, the Swiss Federal Institute of Technology in Lausanne was equipped with a huge heat pump system comprising two electrically driven heat pumps of 3.5 MW thermal power each. The heat source is water drawn from the lake of Geneva at a depth of 70 meters. An annual coefficient of performance of 4.5 has been obtained since the commissioning of the plant. However, most heat pump installations are located in single-family dwellings. The preferred heat source is geothermal heat, using borehole heat exchangers and an intermediate heat transfer fluid. The average coefficient of performance of these installations has been increased from 2.5 in 1995 to 3.1 in 2002

  4. 77 FR 76972 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2012-12-31

    ... motors and pumps and certain other industrial equipment to conserve the energy resources of the nation... the efficiency of electric motors, pumps and certain other industrial equipment to conserve the energy... electric motors as covered equipment. A compressor may have some or all of the following components: piston...

  5. Breastfeeding FAQs: Pumping

    Science.gov (United States)

    ... of pump is best? You can buy or rent a breast pump from lactation consultants, hospitals, retail ... place to do it. Many companies offer their employees pumping and nursing areas. If yours doesn't, ...

  6. Estimated saving potential and efficient use of energy in air conditioning by means of the solar protection; Potencial estimado de ahorro y uso eficiente de energia en aires acondicionados mediante la proteccion solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-07-01

    In here it is presented the analysis of the impact of the solar gains through the transparent parts of a prototype house of social interest, located in a dry warm climate. This analysis was made to determine the gains through windows for the summer time and under the following conditions: without outside solar protections, with the use of eaves, solar breakers and finally with the use of both systems of solar protection. The results were compared to obtain the considered potential of energy saving in cooling equipment, that could be obtained in future houses to build. [Spanish] Se presenta el analisis del impacto de las ganancias solares a traves de las partes transparentes de un prototipo de vivienda de interes social, ubicado en un clima calido seco. Dicho analisis se realizo para determinar las ganancias a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin protecciones solares exteriores, con el empleo de aleros, con quiebrasoles y finalmente con el empleo de ambos sistemas de proteccion solar. Se compararon los resultados para obtener el potencial estimado de ahorro de energia en equipo de enfriamiento, que se tendria en las futuras viviendas por construir.

  7. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  8. Development of liquid nitrogen Centrifugal Pump

    International Nuclear Information System (INIS)

    Abe, M; Sagiyama, R; Tsuchiya, H; Takayama, T; Torii, Y; Nakamura, M; Hoshino, Y; Odashima, Y

    2009-01-01

    Usually liquid nitrogen (LN 2 ) transfer from a container to a laboratory equipment takes place by applying pressure to the container to push out liquid or pouring liquid into the cryostat directly by lifting the container. In order to overcome inconvenience of pressuring or lifting containers, we have been developing the Liquid Nitrogen Centrifugal Pump of a small electric turbine pump. Significant advantages that both reducing time to fill LN 2 and controlling the flow rate of liquid into the cryostat are obtained by introducing this pump. We have achieved the lift of about 800mm with the vessel's opening diameter of 28mm.

  9. Liquid metal pump

    Science.gov (United States)

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  10. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair

  11. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  12. 77 FR 75400 - Labeling Requirements for Commercial and Industrial Equipment

    Science.gov (United States)

    2012-12-20

    ...-intensity discharge lamps, distribution transformers, and small electric motors as covered equipment. (42 U... following: Electric motors and pumps; commercial HVAC and water heating equipment (small, large, and very... prescribed for certain types of covered equipment. Specific requirements are established for electric motors...

  13. Double-shell tank annulus pumping alternative evaluation

    International Nuclear Information System (INIS)

    RIESENWEBER, S.D.

    1999-01-01

    This engineering evaluation compares five alternative schemes for maintaining emergency annulus pumping equipment in a reliable condition. The five schemes are: (1) continue status quo; (2) periodic pump removal and run-in; (3) periodic in-place limited maintenance; (4) uninstalled ready spares; and (5) expanded mission of Single-Shell Tank Emergency Pumping Trailer. Each alternative is described, the pros and cons identified, and rough order of magnitude life-cycle costs computed. The alternatives are compared using weighted evaluation criteria. The evaluation concludes that staging adjustable length submersible pumps in the Single-Shell Tank Emergency Pumping Trailer has the best cost-benefit characteristics

  14. Dry vacuum pumps

    International Nuclear Information System (INIS)

    Sibuet, R

    2008-01-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R and D/industries, merits over conventional pumps and future growth scope will be discussed

  15. Electric energy saving and its impact in the mining industry; El ahorro de energia electrica y su impacto en la industria minera

    Energy Technology Data Exchange (ETDEWEB)

    Urteaga Dufour, Jose Antonio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1994-12-31

    In this paper are shown the most important results of the energy diagnosis performed in some representative industries of the mining industry, where opportunity areas were detected in electric energy saving, starting from those measures that do not require investment up to the ones that require medium investment, recoverable in less than two years terms as a maximum and with electric energy saving ranging from 10% to 25%. [Espanol] En este trabajo, se presentan los resultados mas importantes, obtenidos en el diagnostico energetico realizado en algunas empresas representativas de la rama de la mineria, en donde se detectaron areas de oportunidad de ahorro de energia electrica que van desde aquellas medidas que no requieren inversiones hasta las que requieren medianas inversiones, recuperables en menos de dos anos como maximo y con ahorros de energia que van desde un 10% hasta un 25%.

  16. Electric energy saving and its impact in the mining industry; El ahorro de energia electrica y su impacto en la industria minera

    Energy Technology Data Exchange (ETDEWEB)

    Urteaga Dufour, Jose Antonio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    In this paper are shown the most important results of the energy diagnosis performed in some representative industries of the mining industry, where opportunity areas were detected in electric energy saving, starting from those measures that do not require investment up to the ones that require medium investment, recoverable in less than two years terms as a maximum and with electric energy saving ranging from 10% to 25%. [Espanol] En este trabajo, se presentan los resultados mas importantes, obtenidos en el diagnostico energetico realizado en algunas empresas representativas de la rama de la mineria, en donde se detectaron areas de oportunidad de ahorro de energia electrica que van desde aquellas medidas que no requieren inversiones hasta las que requieren medianas inversiones, recuperables en menos de dos anos como maximo y con ahorros de energia que van desde un 10% hasta un 25%.

  17. Solar Pumping : The Basics

    OpenAIRE

    World Bank Group

    2018-01-01

    Solar photovoltaic water pumping (SWP) uses energy from solar photovoltaic (PV) panels to power an electric water pump. The entire process, from sunlight to stored energy, is elegant and simple. Over last seven years, the technology and price of solar pumping have evolved dramatically and hence the opportunities it presents. Solar pumping is most competitive in regions with high solar inso...

  18. Multiple pump housing

    Science.gov (United States)

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  19. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  20. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  1. 40 CFR 61.242-2 - Standards: Pumps.

    Science.gov (United States)

    2010-07-01

    ... pressure that is at all times greater than the pump stuffing box pressure; or (ii) Equipped with a barrier... system that purges the barrier fluid into a process stream with zero VHAP emissions to atmosphere. (2...

  2. Integral programs of energy conservation (exergy) in the petroleum industry; Programas integrales de ahorro de energia (exergia) en la industria petrolera

    Energy Technology Data Exchange (ETDEWEB)

    Rivero Rodriguez, R. [Instituto Mexicano del Petroleo (IMP), Mexico, D. F. (Mexico)

    1995-12-31

    This paper presents some of the fundamental issues related to energy conservation programs in general and to the petroleum industry in particular with the purpose of integrating them both, that is, considering not only the energy issues, but also the ecological and economical aspects. This is achieved by using the two fundamental laws of thermodynamics (the science that studies energy, its characteristics, and its transformations) through the use of the exergy concept, which is a measure of the energy quality and of its withdrawal with respect to the environment. The origins of the present-day technologies, regarding energy conservation, the short, medium and long term general strategies and the implementation stages of the integral programs of energy conservation are presented, and it concludes with a series of general policies aimed at making the energy conservation programs more congruent with the maintenance of a sustainable development. [Espanol] En este trabajo se presentan algunos aspectos fundamentales relacionados con los programas de ahorro de energia en general, y en la industria petrolera en particular, con objeto de lograr que los mismos sean integrales, es decir que consideren no solo los aspectos puramente energeticos, sino tambien los aspectos ecologicos y economicos. Esto se logra utilizando conjuntamente las dos leyes fundamentales de la termodinamica (la ciencia que estudia la energia, sus caracteristicas y sus transformaciones), mediante la utilizacion del concepto de exergia, que es una medida de la calidad de la energia y de su alejamiento con respecto al medio ambiente. Se presentan los origenes de las tendencias tecnologicas actuales en materia de ahorro de energia, las estrategias generales a corto, mediano y largo plazos y las etapas en la implementacion de programas integrales de ahorro de energia, para concluir con una serie de politicas generales tendientes a lograr que los programas de ahorro de energia sean congruentes con el

  3. Integral programs of energy conservation (exergy) in the petroleum industry; Programas integrales de ahorro de energia (exergia) en la industria petrolera

    Energy Technology Data Exchange (ETDEWEB)

    Rivero Rodriguez, R [Instituto Mexicano del Petroleo (IMP), Mexico, D. F. (Mexico)

    1996-12-31

    This paper presents some of the fundamental issues related to energy conservation programs in general and to the petroleum industry in particular with the purpose of integrating them both, that is, considering not only the energy issues, but also the ecological and economical aspects. This is achieved by using the two fundamental laws of thermodynamics (the science that studies energy, its characteristics, and its transformations) through the use of the exergy concept, which is a measure of the energy quality and of its withdrawal with respect to the environment. The origins of the present-day technologies, regarding energy conservation, the short, medium and long term general strategies and the implementation stages of the integral programs of energy conservation are presented, and it concludes with a series of general policies aimed at making the energy conservation programs more congruent with the maintenance of a sustainable development. [Espanol] En este trabajo se presentan algunos aspectos fundamentales relacionados con los programas de ahorro de energia en general, y en la industria petrolera en particular, con objeto de lograr que los mismos sean integrales, es decir que consideren no solo los aspectos puramente energeticos, sino tambien los aspectos ecologicos y economicos. Esto se logra utilizando conjuntamente las dos leyes fundamentales de la termodinamica (la ciencia que estudia la energia, sus caracteristicas y sus transformaciones), mediante la utilizacion del concepto de exergia, que es una medida de la calidad de la energia y de su alejamiento con respecto al medio ambiente. Se presentan los origenes de las tendencias tecnologicas actuales en materia de ahorro de energia, las estrategias generales a corto, mediano y largo plazos y las etapas en la implementacion de programas integrales de ahorro de energia, para concluir con una serie de politicas generales tendientes a lograr que los programas de ahorro de energia sean congruentes con el

  4. Pulsatile fluidic pump demonstration and predictive model application

    International Nuclear Information System (INIS)

    Morgan, J.G.; Holland, W.D.

    1986-04-01

    Pulsatile fluidic pumps were developed as a remotely controlled method of transferring or mixing feed solutions. A test in the Integrated Equipment Test facility demonstrated the performance of a critically safe geometry pump suitable for use in a 0.1-ton/d heavy metal (HM) fuel reprocessing plant. A predictive model was developed to calculate output flows under a wide range of external system conditions. Predictive and experimental flow rates are compared for both submerged and unsubmerged fluidic pump cases

  5. 46 CFR 95.10-5 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 95.10-5 Section 95.10-5 Shipping COAST GUARD... Main System, Details § 95.10-5 Fire pumps. (a) Vessels shall be equipped with independently driven fire pumps in accordance with Table 95.10-5(a). Table 95.10-5(a) Gross tons Over Not over Minimum number of...

  6. Pumps, valves and fittings:the life cycle cost of the equipments, war-horse of the AFPR (association francaise des pompes et de la robinetterie); Pompes et robinetterie: le cout du cycle de vie des equipements, cheval de bataille de l'AFPR

    Energy Technology Data Exchange (ETDEWEB)

    Deboutte, G.

    2005-07-01

    The cheaper product is not necessarily the less expensive. Here is, in summary, the concept of the life cycle cost of the equipments, according to the AFPR, which sees here an answer to the Asiatic competition and a mean to optimize the energy consumptions. (O.M.)

  7. Ahorre Energia: Consejos sobre el ahorro de dinero y energia en el hogar (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    Learn how to save money with Energy Saver: Tips on Saving Money & Energy at Home, from the U.S. Department of Energy. The Energy Saver guide will help you reduce your monthly energy costs and live more efficiently. This guide takes you through the systems and appliances that consume the most energy in your home, and provides solutions to cut costs for you while saving the environment. The Energy Saver guide also includes transportation tips to help you save money at the pump.

  8. Análisis de ahorro energético en iluminación LED industrial: Un estudio de caso

    Directory of Open Access Journals (Sweden)

    Ana Serrano-Tierz

    2015-01-01

    Full Text Available El presente estudio muestra el ahorro económico y las ventajas medioambientales que supone la iluminación industrial con tecnología LED. Se ha planteado un estudio de caso en el que luminarias de halogenuros metálicos han sido sustituidas por luminarias LED. Para validar la sustitución de luminarias con halogenuros metálicos de 400W por LED de 200W, se han efectuado las simulaciones luminotécnicas y mediciones de campo mediante luxómetro. Los resultados obtenidos indican que ambas luminarias son equiparables obteniendo un importante ahorro energético cercano al 50%. Esta investigación demuestra que la tecnología LED ofrece soluciones de iluminación de alto rendimiento que optimizan el ahorro energético reduciendo a su vez costes de mantenimiento con un coste total de propiedad significativamente menor, incrementando la esperanza de vida útil de las luminarias. Desde el punto de vista medioambiental supone una importante reducción en emisiones de CO2 y eliminación de residuos tóxicos como el mercurio.

  9. Power Consumption Optimization for Multiple Parallel Centrifugal Pumps

    DEFF Research Database (Denmark)

    Jepsen, Kasper Lund; Hansen, Leif; Mai, Christian

    2017-01-01

    Large amounts of energy is being used in a wide range of applications to transport liquid. This paper proposes a generic solution for minimizing power consumption of a generic pumping station equipped with identical variable speed pumps. The proposed solution consists of two sequential steps; fir...

  10. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  11. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  12. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    Science.gov (United States)

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  13. DOUBLE SHELL TANK EMERGENCY PUMPING GUIDE

    International Nuclear Information System (INIS)

    REBERGER, D.W.

    2006-01-01

    This document provides preplanning necessary to expeditiously remove any waste that may leak from the primary tank to the secondary tank for Hanford's 28 DSTs. The strategy is described, applicable emergency procedures are referenced, and transfer routes and pumping equipment for each tank are identified

  14. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  15. Continuously pumping and reactivating gas pump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Call, W.R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped

  16. Continuously pumping and reactivating gas pump

    Science.gov (United States)

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  17. Method of starting internal pumps of a nuclear reactor

    International Nuclear Information System (INIS)

    Kumagami, Shoji.

    1985-01-01

    Purpose: To reduce the noise effects by decreasing the invading current into the main line upon starting an internal pump type nuclear reactor adapted to forcively recycle the reactor water by a plurality of internal pumps. Method: A plurality of internal pumps are divided into several groups and, upon starting pumps belonging to the individual unit group, the starting instances for the respective pumps are deviated to reduce the surges applied to the main line and suppress the invading current lower to reduce the earth noises. As a result, effects caused to other devices or equipments can be moderated to improve the reliability. Furthermore, by actuating the respective pumps on every group units in a starting pattern along the orthogonal line, flow rate distribution in the reactor can be balanced. Then, the instability region during low rotation of pumps, that is, instability of the flow rate near the resonance frequency can be decreased. (Kawakami, Y.)

  18. Particles pumping in Tore Supra

    International Nuclear Information System (INIS)

    Bonnel, P.; Chappuis, P.; Lipa, M.

    1989-01-01

    TORE SUPRA and its peripheral equipments are provided with routine clean high vacuum by turbomolecular pumping. During plasma discharges large quantity of very hot gases activating at plasma edge and plasma density in scrape off layer has to be controlled before they strike violently solid wall provoking increase in impurities content and make density up to disruptive level. A Magnetic Ergodic Divertor made of six winding structures - MED - six Vertical Pumped Limiters - VPL - and one Horizontal Pumped Limiter - HPL - are set in the vacuum chamber in order to cope with plasma-wall interactions and neutral gas recycling. Each apparatus is equipped at front side with thermal shield respectively made of polycristallin and pyrolitic graphite bolted on stainless steel support for MED and HPL whereas for VPL it is made of CFC Aerolor 05 brazed on hardened copper. The total heat removal capacity of these plasma facing components is 12 MW. Design of particles collection openings and ducts conductance allow 10% of capture efficiency, that means for TORE SUPRA a flux of 3 x 10 21 particles/second has to be sorbed by water cooled titanium getter pumps, settled at rear side. All those facilities were put into plasma operation at the beginning of 1989 for a short time. Preliminary observations go along with theoretical predictions, that actions in scrappe-off layer may provoke effects in bulk plasma. Very first results drawn out, show that particle collection and heat removal were effective by MED, VPL and HPL and that plasma behaviour was not disturbed by their presence and actions but instead tendency to improvement was observed

  19. Las puzolanas y el ahorro energético en los materiales de construcción

    Directory of Open Access Journals (Sweden)

    Soria Santamaría, Francisco

    1983-09-01

    Full Text Available This discussion commences with some general comments on the energy crisis and its impact on the cement industry, with the corresponding coal reconversion problems. Three factors are highlighted where saving has been centered: technological process, raw materials and finished product, emphasizing the interest of latter which includes incorporating active additions in Portland cement. A quick review then follows about pozzolanas, their origin, definitions and classification. Their chemical composition is underlined, and the concept of pozzolanic activity is described. Later on, pozzolanic cements, their most significant properties and the advantages of using pozzolana are explained. After a lengthy description about possible applications of pozzolanas and pozzolanic cements, the conclusion reviews current trends in international standards for such cements and possible evolution in consumption of additions by the year 2000, with a view to saving more energy, without impairing the essential properties of the cement.

    Comienza esta exposición con unas consideraciones generales sobre la crisis energética y su impacto en la industria cementera, con los correspondientes problemas de reconversión al carbón. Se mencionan los tres aspectos en que se ha centrado el ahorro energético: proceso tecnológico, materias primas y producto acabado, destacando el interés de este último que incluye la incorporación de adiciones activas al cemento portland. Se hace a continuación un rápido comentario sobre puzolanas, su origen, definiciones y clasificación. Se destaca la composición química de las mismas y se desarrolla el concepto de actividad puzolánica. Más tarde se hace una exposición sobre cementos puzolánicos, sus propiedades más destacadas y las ventajas que supone el empleo de la puzolana. Tras una exposición amplia de las posibles aplicaciones de las puzolanas y cementos puzolánicos, se concluye comentando las tendencias

  20. National potential of saving of electricity in domestic refrigeration; Potencial nacional de ahorro de electricidad en refrigeracion domestica

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo C, Fernando [Universidad Nacional Autonoma de Mexico (Mexico); Ambriz G, Juan Jose; Romero P, Hernando [Universidad Autonoma Metropolitana, (Mexico)

    2003-07-01

    In the present paper the evaluation of the potential of saving of electrical energy in Mexico is presented, by means of the substitution of old refrigerators of low efficiency by modern high efficiency ones. This potential is very ample, since the replacement of the old models by new follows a very slow curve, if the economic difficulties of the Mexican families are considered and that, on the other hand, the technology of the domestic refrigerators is so reliable that they have a very long life and they are not easily rejected. In field work have been found refrigerators operating with ages of more than 30 years and still 40. In Mexico, it is estimated that the refrigeration is responsible for around 29% of the of electricity consumption in homes settled in tempered climate and of 14 % in those of warm climate in which air conditioning is used. The proposal of this work is the organization of a governmental program of accelerated substitution of refrigerators that helps to acquire an efficient refrigerator and to reject the old ones. The results indicate that if a total renovation of the park of domestic refrigerators is made, the saving of electrical energy would reach the 5.2 TWh/a which represents the 44.5% of the total consumption of 11.7 TWh in a year. [Spanish] En el presente trabajo se presenta la evaluacion del potencial de ahorro de energia electrica en Mexico, mediante la substitucion de refrigeradores antiguos de baja eficiencia por modernos de alta eficiencia. Este potencial es muy amplio, ya que el reemplazo de los modelos viejos por nuevos sigue una curva muy lenta, si se consideran las dificultades economicas de las familias mexicanas y que, por otro lado, la tecnologia de los refrigeradores domesticos es tan confiable que tienen una vida muy larga y no se desechan facilmente. En trabajos de campo se han encontrado refrigeradores operando con edades de mas de 30 anos y aun 40. En Mexico, se estima que la refrigeracion es responsable de alrededor del

  1. Cost-benefit of energy saving in bioclimatic designs; Costo-beneficio del ahorro de energia en los disenos bioclimatios

    Energy Technology Data Exchange (ETDEWEB)

    Lopez P, J. Manuel A. [Doble dos soluciones de Negocios (Mexico); Morillon G, David; Rdriguez V, Luis [Universidad Autonoma de Mexico (Mexico)

    2001-06-01

    Tools and criteria for Cost-Benefit Analysis (ACB) of energy saving in bioclimatic designs (DB) are presented, for which a reference project is established. Based on the traditional design of air conditioning of a building and with the support of this one, the estimation of costs and benefits of the same building is made; but with passive systems. The tools used consider related resources such as time and money. Criteria are used such as: Present value (VP), Equivalent Annual Cost (EAC) and the Cost of the conserved Energy (CEC). The costs related to the construction, maintenance and operation of the design are taken into consideration. The differences between the design of reference and the Bioclimatic Design, established from the application of these criteria, allow evaluating the economic margin as far as operation and maintenance. Finally, the cost of the conserved energy of the bioclimatic measures is evaluated as an initiative for energy saving and calculates the present value from them in all of the period of useful life of the bioclimatic design. [Spanish] Se presentan herramientas y criterios para el analisis Costo-Beneficio (ACB) del ahorro de energia en los disenos bioclimaticos (DB), para lo cual se establece un proyecto de referencia. Basado en el diseno tradicional de la climatizacion de un edificio y con apoyo en este, se realiza la estimacion de costos y beneficios del mismo edificio; pero con sistema pasivos. Las herramientas usadas consideran recursos relacionados como son tiempo y dinero. Se usan criterios tales como: Valor Presente (VP), Costo Anual Equivalente (CAE) y el Costo de la Energia conservada (CEC). Se toman en consideracion los costos relacionados con la construccion, mantenimiento y operacion del diseno. Las diferencias entre el diseno de referencia y el Diseno Bioclimatico, establecidas a partir de la aplicacion de estos criterios, permiten evaluar el margen economico en cuanto a la operacion y el mantenimiento. Finalmente, se

  2. Projects of electrical energy saving in Costa Rica; Proyectos de ahorro de energia electrica en Costa Rica

    Energy Technology Data Exchange (ETDEWEB)

    Chinchilla, Henry [Compania Nacional de Luz y Fuerza, S.A., San Jose (Costa Rica)

    1999-07-01

    Costa Rica, located in Central America, is a highly electrified country, more of the 93.6% of the population, has access to the electricity, and its load curve presents two important demand peaks, one of them near noon and another one at sundown, additionally, the growth of this service is important, reason why it has been oriented to the establishment of actions focussed to the better use of the energy, in special of the electricity. The following notes are intended to show briefly the origin of the actions oriented to the energy saving, identifying the main projects that marked an important track in the national development in this sense, as well as a sample of some of the projects which have permitted to maintain throughout the last decade of this century a permanent attitude on the promotion and education of the saving and handling of the energy demand, specially of electricity, of such a way as to a suitable contribution is achieved towards the industrial competitiveness, human comfort and environmental protection. [Spanish] Costa Rica, ubicado en la America Central, es un pais altamente electrificado, mas del 93.6% de la poblacion, tiene acceso a la electricidad, y su curva de carga presenta dos importantes picos de demanda uno cercano al medio dia y otro al ocultarse el sol, junto a ello el crecimiento este servicio es importante, por lo que se ha abocado a establecer acciones que se orientan al mejor uso de la energia, en especial de la electricidad. En las siguientes notas se trata de mostrar en forma breve el origen de las acciones orientadas al ahorro de energia, identificando los principales proyectos que marcaron una huella importante en el rumbo nacional en este sentido, asi como una muestra de algunos de los proyectos que han permitido mantener a lo largo de la ultima decada de este siglo una permanente actitud de la promocion y ensenanza del ahorro y manejo de la demanda de energia, en especial de la electricidad, de tal forma que se logre con ello

  3. The relation between preventive maintenance and energy saving, planning and production control; La relacion entre el mantenimiento preventivo y el ahorro de energia planeacion y control de la produccion

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Cazarez, Mario [Coorporacion de ingenieros en aire acondicionado y mantenimiento en general (Mexico)

    2003-07-01

    In this paper the importance that the preventive maintenance has as an important ingredient of the internal policies of the companies for the promotion of the energy saving is discussed. It considers that the department of planning and production control must take into account very seriously the importance of programmed preventive maintenance in order to maintain the continuity of the production process and with this eliminate the bottle necks that adversely affect it and consequently the the company's image before the clients, besides contributing positively the promotion of energy saving. The faults that stop the production process inflict losses of income and adversely affect the yield of the company, in addition, they increase the production cost or the plant expenses associated to the repair of the damaged equipment, in the worst of the cases, important penalties will have to be paid for the delayed delivery of the product to the client. By keeping the correct operation of the equipment, increasing its availability and assuring that all the safeties of these operate correctly we will be contributing to the optimal operation of the enterprise system and avoiding the additional consumption of energy associated to the failure of an equipment and interruption of the production line. The preventive maintenance also promotes, the order and the cleanliness, the safety and hygiene in the work centers and the protection to the environment. Once the prevention has won the battle to the correction, one enters the field of diagnosis, handling the service periods in an optimal way in benefit of the production line. In this stage it can be spoken of entering the application of Total Productive Maintenance. [Spanish] En este trabajo se discute la importancia que tiene el mantenimiento preventivo como un ingrediente importante de las politicas internas de las empresas para la promocion del ahorro de energia. Considera que el departamento de planeacion y control de la

  4. The relation between preventive maintenance and energy saving, planning and production control; La relacion entre el mantenimiento preventivo y el ahorro de energia planeacion y control de la produccion

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Cazarez, Mario [Coorporacion de ingenieros en aire acondicionado y mantenimiento en general (Mexico)

    2003-07-01

    In this paper the importance that the preventive maintenance has as an important ingredient of the internal policies of the companies for the promotion of the energy saving is discussed. It considers that the department of planning and production control must take into account very seriously the importance of programmed preventive maintenance in order to maintain the continuity of the production process and with this eliminate the bottle necks that adversely affect it and consequently the the company's image before the clients, besides contributing positively the promotion of energy saving. The faults that stop the production process inflict losses of income and adversely affect the yield of the company, in addition, they increase the production cost or the plant expenses associated to the repair of the damaged equipment, in the worst of the cases, important penalties will have to be paid for the delayed delivery of the product to the client. By keeping the correct operation of the equipment, increasing its availability and assuring that all the safeties of these operate correctly we will be contributing to the optimal operation of the enterprise system and avoiding the additional consumption of energy associated to the failure of an equipment and interruption of the production line. The preventive maintenance also promotes, the order and the cleanliness, the safety and hygiene in the work centers and the protection to the environment. Once the prevention has won the battle to the correction, one enters the field of diagnosis, handling the service periods in an optimal way in benefit of the production line. In this stage it can be spoken of entering the application of Total Productive Maintenance. [Spanish] En este trabajo se discute la importancia que tiene el mantenimiento preventivo como un ingrediente importante de las politicas internas de las empresas para la promocion del ahorro de energia. Considera que el departamento de planeacion y control de la

  5. Energy efficient ammonia heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Claus; Pijnenburg, B.; Schumann Grindorf, H. [Danish Technological Institute, Aarhus (Denmark); Christensen, Rolf [Alfa Laval, Lund (Sweden); Rasmussen, Bjarne D. [Grundfos, Bjerringbro (Denmark); Gram, S.; Fredborg Jakobsen, D. [Svedan Industri Koeleanlaeg, Greve (Denmark)

    2013-09-15

    The report describes the development of a highly effective ammonia heat pump. Heat pumps play an increasingly important role in the search for more effective use of energy in our society. Highly efficient heat pumps can contribute to reduced energy consumption and improved economy of the systems which they are a part of. An ammonia heat pump with high pressure reciprocating compressor and a novel split condenser was developed to prove potential for efficiency optimization. The split of the condenser in two parts can be utilized to obtain smaller temperature approaches and, thereby, improved heat pump efficiency at an equal heat exchanger area, when compared to the traditional solution with separate condenser and de-superheater. The split condenser design can also be exploited for heating a significant share of the total heating capacity to a temperature far above the condensing temperature. Furthermore, the prototype heat pump was equipped with a plate type evaporator combined with a U-turn separator with a minimum liquid height and a liquid pump with the purpose of creating optimum liquid circulation ratio for the highest possible heat transfer coefficients at the lowest possible pressure drop. The test results successfully confirmed the highest possible efficiency; a COP of 4.3 was obtained when heating water from 40 deg. C to 80 deg. C while operating with evaporating/condensing temperatures of +20 deg C/+73 deg C. (Author)

  6. Fuzzy Activity Based Life Cycle Costing For Repairable Equipment

    Directory of Open Access Journals (Sweden)

    Mulubrhan Freselam

    2016-01-01

    Full Text Available Life-cycle cost (LCC is the much known method used for decision making that considers all costs in the life of a system or equipment. Predicting LCCs is fraught with potential errors, owing to the uncertainty in future events, future costs, interest rates, and even hidden costs. These uncertainties have a direct impact on the decision making. Activity based LCC is used to identify the activities and cost drivers in acquisition, operation and maintenance phase. This activity based LCC is integrated with fuzzy set theory and interval mathematics to model these uncertainties. Day–Stout–Warren (DSW algorithm and the vertex method are then used to evaluate competing alternatives. A case of two pumps (Pump A and Pump B are taken and their LCC is analysed using the developed model. The equivalent annual cost of Pump B is greater than Pump A, which leads the decision maker to choose Pump A over Pump B.

  7. 46 CFR 28.255 - Bilge pumps, bilge piping, and dewatering systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Bilge pumps, bilge piping, and dewatering systems. 28... the Aleutian Trade § 28.255 Bilge pumps, bilge piping, and dewatering systems. (a) Each vessel must be equipped with a bilge pump and bilge piping capable of draining any watertight compartment, other than...

  8. 40 CFR 63.1026 - Pumps in light liquid service standards.

    Science.gov (United States)

    2010-07-01

    ... this section. (A) Each dual mechanical seal system is operated with the barrier fluid at a pressure... monomers; (ii) 2,000 parts per million or greater for pumps in food/medical service; and (iii) 1,000 parts...—(1) Dual mechanical seal pumps. Each pump equipped with a dual mechanical seal system that includes a...

  9. 40 CFR 65.107 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... mechanical seal pumps. Each pump equipped with a dual mechanical seal system that includes a barrier fluid... million or greater for pumps in food/medical service; and (iii) 1,000 parts per million or greater for all... frequency of drips and to the sensor that indicates failure of the seal system, the barrier fluid system, or...

  10. Hydraulic speed variators for electrical energy saving; Variadores de velocidad hidraulicos para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Mexico, D. F. (Mexico)

    1999-07-01

    This paper shows the characteristics and applications of the hydraulic speed variators, where because of the conditions of the industrial processes it is necessary to vary the operation parameters, obtaining therefore an energy saving besides improving the control of these processes. In addition, the technical and economic evaluation is presented of a project of the Mazatlan Fossil Power Plant, in which it is intended to invest in the installation of a hydraulic speed variator connected to the forced draft fan of unit number three, which operates with an induction motor of 1,865 kW (2,500 H.P.), with a Voltage of 4,180 V at 1,180 rpm. [Spanish] El presente trabajo muestra las caracteristicas y aplicaciones de los variadores de velocidad hidraulicos, donde por las condiciones de los procesos industriales sea necesario variar los parametros de operacion, obteniendose asi un ahorro de energia ademas de mejorar el control de dichos procesos. Se presenta ademas la evaluacion tecnica y economica de un proyecto de la Planta Termoelectrica Mazatlan, en donde se pretende invertir en la instalacion de un variador de velocidad hidraulico acoplado al ventilador de tiro forzado de la unidad numero tres, el cual opera con un motor de induccion de 1,865 kW (2,500 H.P.), con un voltaje de 4,180 V y una velocidad de 1,180 rpm.

  11. Potential of bioclimatic architecture for energy saving in buildings; Potencial de la arquitectura bioclimatica para ahorro de energia en edificios

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Chavez, Jose Roberto [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1994-12-31

    The design and construction of current buildings has been characterized, most of all, in the last 30 years, for the lack of consideration in the design process of aspects that nowadays represent a fundamental importance. These aspects are related to energy conservation and environmental protection, with man as the main center of attention for the optimum satisfaction of its physiological as well as psychological needs. In this paper are presented the causes for the lack of consideration of the mentioned aspects and guidelines to follow are set forth for their integration in the design process. Also the architecture potential with a bioclimatic approach is analyzed, for energy saving in buildings. [Espanol] El diseno y construccion de edificios contemporaneos se ha caracterizado, sobre todo en los ultimos treinta anos, por la falta de consideracion en el proceso de diseno, de aspectos que hoy en dia revisten una importancia primordial. Estos aspectos se relacionan con la preservacion de la energia y del medio ambiente, teniendo al hombre como principal centro de atencion, para la satisfaccion optima de sus necesidades, tanto fisiologicas como psicologicas. En este trabajo, se presentan las causas de la falta de consideracion de los aspectos antes citados y se plantean las pautas a seguir para su integracion en el proceso de diseno. Asi mismo, se analiza el potencial de la arquitectura con un enfoque bioclimatico, para ahorro de energia en los edificios.

  12. Energy saving by the use of polystyrene in construction; Ahorro de energia por la utilizacion de poliestireno en la construccion

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel, Raul [Polioles S. A. de C. V., Mexico, D. F. (Mexico)

    1993-12-31

    In the past last years, the building industry has been faced with requirements in the rational energy use and environmental preservation. The polystyrene foam is a material that for more than forty years has demonstrated its attributes all over the world in its application in the construction industry as well as in the packing and crating industries, becoming a synonym of economic construction in regard to energy saving and a synonym also of a rational and safe packing. In this paper a short description is made of the manufacturing process of the expandable polystyrene foam, its properties and applications in the construction industry. [Espanol] En los ultimos anos, la industria de la construccion se ha enfrentado a exigencias en el uso racional de la energia y en la preservacion del medio ambiente. La espuma de poliestireno expansible es un material que por mas de cuarenta anos, ha demostrado sus cualidades a nivel mundial en su aplicacion tanto en la industria de la construccion como en la del empaque y embalaje, llegando a convertirse en sinonimo de una construccion economica en cuanto a ahorro de energia y sinonimo tambien de un embalaje racional y seguro. En este trabajo se hace una breve descripcion del proceso de fabricacion de la espuma de poliestireno expandible, sus propiedades y aplicaciones dentro de la industria de la construccion.

  13. Energy saving by the use of polystyrene in construction; Ahorro de energia por la utilizacion de poliestireno en la construccion

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel, Raul [Polioles S. A. de C. V., Mexico, D. F. (Mexico)

    1992-12-31

    In the past last years, the building industry has been faced with requirements in the rational energy use and environmental preservation. The polystyrene foam is a material that for more than forty years has demonstrated its attributes all over the world in its application in the construction industry as well as in the packing and crating industries, becoming a synonym of economic construction in regard to energy saving and a synonym also of a rational and safe packing. In this paper a short description is made of the manufacturing process of the expandable polystyrene foam, its properties and applications in the construction industry. [Espanol] En los ultimos anos, la industria de la construccion se ha enfrentado a exigencias en el uso racional de la energia y en la preservacion del medio ambiente. La espuma de poliestireno expansible es un material que por mas de cuarenta anos, ha demostrado sus cualidades a nivel mundial en su aplicacion tanto en la industria de la construccion como en la del empaque y embalaje, llegando a convertirse en sinonimo de una construccion economica en cuanto a ahorro de energia y sinonimo tambien de un embalaje racional y seguro. En este trabajo se hace una breve descripcion del proceso de fabricacion de la espuma de poliestireno expandible, sus propiedades y aplicaciones dentro de la industria de la construccion.

  14. Noise control of radiological monitoring equipment

    International Nuclear Information System (INIS)

    Rubick, R.D.; Stevens, W.W.; Burke, L.L.

    1998-01-01

    Although vacuum pumps on continuous air monitors (CAMs) do not produce noise levels above regulatory limits, engineering controls were used to establish a safer work environment. Operations performed in areas where CAMs are located are highly specialized and require precision work when handling nuclear materials, heavy metals, and inert gases. Traditional methods for controlling noise such as enclosing or isolating the source and the use of personal protection equipment were evaluated. An innovative solution was found by retrofitting CAMs with air powered multistage ejectors pumps. By allowing the air to expand in several chambers to create a vacuum, one can eliminate the noise hazard altogether. In facilities with adequate pressurized air, use of these improved ejector pumps may be a cost-effective replacement for noisy vacuum pumps. A workplace designed or engineered with noise levels as low as possible or as close to background adds to increased concentration, attention to detail, and increased production

  15. Pumps in mining

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    This article looks at the pump industry as a whole, its historical links with the mining industry, their parallel develop ment, and at the individual manufacturers and pumps, services and auxillary products they have to offer.

  16. Photovoltaic pump systems

    Science.gov (United States)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  17. Analysis of Dynamic Characteristics of Water Injection Pump

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Myeong; Lee, Jeong Hoon; Ha, Jeong Min; Ahn, Byung Hyun; Kim, Won Cheol; Choi, Byeong Keun [Gyeongsang Nat' l Univ., Jinju (Korea, Republic of)

    2013-12-15

    Water injection pump outputs oil with high pressure during this process, seawater is injected into the well to recover the well pressure and maintain high productivity. A water injection pump has high productivity, and herefore, it serves as a key piece of equipment in marine plants. In this light, water injection pumps are being studied widely in industry. In this study, the rotor dynamics is analyzed to determine the natural frequency according to the bearing stiffness and operation speed change. This study aims to establish the pump reliability through critical speed, stability, and unbalance response analysis.

  18. Rotary magnetic heat pump

    Science.gov (United States)

    Kirol, L.D.

    1987-02-11

    A rotary magnetic heat pump constructed without flow seals or segmented rotor accomplishes recuperation and regeneration by using split flow paths. Heat exchange fluid pumped through heat exchangers and returned to the heat pump splits into two flow components: one flowing counter to the rotor rotation and one flowing with the rotation. 5 figs.

  19. Vertical pump assembly

    International Nuclear Information System (INIS)

    Dohnal, M.; Rosel, J.; Skarka, V.

    1988-01-01

    The mounting is described of the drive assembly of a vertical pump for nuclear power plants in areas with seismic risk. The assembly is attached to the building floor using flexible and damping elements. The design allows producing seismically resistant pumps without major design changes in the existing types of vertical pumps. (E.S.). 1 fig

  20. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  1. Test Procedure - pumping system for caustic addition project

    International Nuclear Information System (INIS)

    Leshikar, G.A.

    1994-01-01

    This test procedure provides the requirements for sub-system testing and integrated operational testing of the submersible mixer pump and caustic addition equipment by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E)

  2. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  3. Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods

    Science.gov (United States)

    Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi

    2010-06-01

    Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.

  4. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.A.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. These can generally be classified as: Mechanical; Hydraulic; Tribological; Chemical; and Other (including those associated with the pump driver). Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump

  5. Liquid metal pump

    International Nuclear Information System (INIS)

    Pennell, W.E.

    1981-01-01

    A liquid metal pump comprising a shaft support structure which is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft carries an impeller and the support structure carries an impeller cage which is slidably disposed in a diffuser so as to allow complete removal of pump internals for inspection and repair. The diffuser is concentrically supported in the pump housing which also takes up all reaction forces generated by the discharge of the liquid metal from the diffuser, with floating seals arranged between impeller cage and the diffuser. The space between the diffuser and the pump housing permits the incoming liquid to essentially surround the diffuser. (author)

  6. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  7. 10 CFR 434.404 - Building service systems and equipment.

    Science.gov (United States)

    2010-01-01

    ... requirements require 24-hour pump operation. 404.5.2Heated swimming pools shall be equipped with pool covers... 10 Energy 3 2010-01-01 2010-01-01 false Building service systems and equipment. 434.404 Section 434.404 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND...

  8. 40 CFR 63.1331 - Equipment leak provisions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Equipment leak provisions. 63.1331... Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1331 Equipment leak... in pumps and agitator seals in light liquid service shall not be considered to be a leak. For...

  9. Qualification of electric equipments for nuclear power plants

    International Nuclear Information System (INIS)

    Chauvin, G.; Raimondo, E.

    1983-03-01

    Description of the testing equipment, testing methods and standards of the resistance to seisms of electrical equipments (switches, pump motors, electrovalves, ...) for electronuclear power plants in France. Presentation of the French design and construction rules for electrical devices in the domestic and export nuclear market (resistance to thermodynamical and chemical stresses, to seisms, etc...) [fr

  10. Pumps for nuclear facilities

    International Nuclear Information System (INIS)

    1999-01-01

    The guide describes how the Finnish Radiation and Nuclear Safety Authority (STUK) controls pumps and their motors at nuclear power plants and other nuclear facilities. The scope of the control is determined by the Safety Class of the pump in question. The various phases of the control are: (1) review of construction plan, (2) control of manufacturing, and construction inspection, (3) commissioning inspection, and (4) control during operation. STUK controls Safety Class 1, 2 and 3 pumps at nuclear facilities as described in this guide. STUK inspects Class EYT (non-nuclear) pumps separately or in connection with the commissioning inspections of the systems. This guide gives the control procedure and related requirements primarily for centrifugal pumps. However, it is also applied to the control of piston pumps and other pump types not mentioned in this guide

  11. Internal pump monitoring device

    International Nuclear Information System (INIS)

    Kurosaki, Toshikazu.

    1996-01-01

    In the present invention, a thermometer is disposed at the upper end of an internal pump casing of a coolant recycling system in a BWR type reactor to detect leakage of reactor water thereby ensuring the improvement of reliability of the internal pump. Namely, a thermometer is disposed, which can detect temperature elevation occurred when water in the internal pump leaked from a reactor pressure vessel passes through the gap between a stretch tube and an upper end of the pump casing. Signals from the thermometer are transmitted to a signal processing device by an instrumentation cable. The signal processing device generates an alarm when the temperature signal exceeds a predetermined value and announces that leakage of reactor water occurs in the internal pump. Since the present invention can detect the leakage of the reactor water in the pump casing in an early stage, it can contribute to the improvement of the safety and reliability of the internal pump. (I.S.)

  12. Equipment qualification research program: program plan

    International Nuclear Information System (INIS)

    Dong, R.G.; Smith, P.D.

    1982-01-01

    The Lawrence Livermore National Laboratory (LLNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC) has developed this program plan for research in equipment qualification (EQA). In this report the research program which will be executed in accordance with this plan will be referred to as the Equipment Qualification Research Program (EQRP). Covered are electrical and mechanical equipment under the conditions described in the OBJECTIVE section of this report. The EQRP has two phases; Phase I is primarily to produce early results and to develop information for Phase II. Phase I will last 18 months and consists of six projects. The first project is program management. The second project is responsible for in-depth evaluation and review of EQ issues and EQ processes. The third project is responsible for detailed planning to initiate Phase II. The remaining three projects address specific equipment; i.e., valves, electrical equipment, and a pump

  13. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  14. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-12-31

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  15. Pumping behavior of sputtering ion pump

    Energy Technology Data Exchange (ETDEWEB)

    Chou, T.S.; Bittner, J.; Schuchman, J.

    1991-01-01

    To optimize the design of a distributed ion pump (DIP) for the Superconducting X-Ray Lithography Source (SXLS) the stability of the rotating electron cloud at very high magnetic field beyond transition, must be re-examined. In this work the pumping speed and frequency spectrum of a DIP at various voltages (1 to 10 KV) and various magnetic fields (0.1 to 4 Tesla) are measured. Three cell diameters 10 mm, 5 mm and 2.5 mm, each 8 mm long, and with 3 or 4 mm gaps between anode and cathode are investigated. In this study both the titanium cathodes and the stainless steel anode plates are perforated with holes comparable in size to the anode cell diameters. Only the partially saturated pumping behavior is under investigation. The ultimate pressure and conditioning of the pump will be investigated at a later date when the stability criterion for the electron cloud is better understood.

  16. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  17. 19. National seminar on the rational use of energy and exposition of equipment and services. Transactions. [Selected Papers]; 19. Seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This document contains the technical proceedings of the 19 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Pofesionistas en Aplicacion Energetica (ATPAE) (Association of Technicians and Professionals on Energy Application) conducted in Mexico City on September 21-25, 1998. This seminar encompassed subjects such as: energy saving in the energy sector, energy efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in buildings, transportation, non-renewable energy utilization and environmental impact and eco-energies. [Espanol] Este documento contiene la memoria tecnica del 19 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F, los dias 21-25 de septiembre de 1998. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables, e impacto ambiental y eco-energias.

  18. Proceedings of the 20 National seminar on the rational use of energy and exposition of equipment and services. [Selected Papers]; 20. Seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This document contains the proceedings of the 20 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociaciacion de Tenicos y Profesionistas en Aplicacion Energetica (ATPAE), in Mexico, D.F, from the 15 to the 19 of November of 1999. This Seminar covered subjects such as: Energy saving in the power sector, power efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in constructions, transport, utilization of renewable energies, and energy and the environment. [Spanish] Este documento contiene la memoria tecnica del 20 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F., del 15 al 19 de noviembre de 1999. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables, y energia y ambiente.

  19. Proceedings of the 21 National seminar on the rational use of energy and exposition of equipment and services. [Selected Papers]; 21 Seminario nacional sobre el uso racional del a energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This document contains the proceedings of the 21 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), in Mexico, D.F., from the 14 to the 16 of March of 2001. This Seminar covered subjects such as: Energy saving in the power sector, power efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in constructions, transport, utilization of renewable energies and the environment. [Spanish] Este documento contiene la memoria tecnica del 21 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F., del 14 al 16 de marzo de 2001. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables y ambiente.

  20. 19. National seminar on the rational use of energy and exposition of equipment and services. Transactions. [Selected Papers]; 19. Seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    This document contains the technical proceedings of the 19 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Pofesionistas en Aplicacion Energetica (ATPAE) (Association of Technicians and Professionals on Energy Application) conducted in Mexico City on September 21-25, 1998. This seminar encompassed subjects such as: energy saving in the energy sector, energy efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in buildings, transportation, non-renewable energy utilization and environmental impact and eco-energies. [Espanol] Este documento contiene la memoria tecnica del 19 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F, los dias 21-25 de septiembre de 1998. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables, e impacto ambiental y eco-energias.

  1. Vertical pump turbine oil environmental evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Culver, G.

    1991-04-01

    In Oregon low-temperature geothermal injection well construction, siting and receiving formations requires approval by the Water Resources Department (OWRD). In addition, the Oregon Department of Environmental Quality (ODEQ) has regulations concerning injection. Conversations with the OWRD and ODEQ representatives indicated they were very concerned about the potential for contamination of the geothermal (and cooler but hydraulically connected) aquifers by oils and grease. Their primary concern was over the practice of putting paraffin, motor oils and other hydrocarbons in downhole heat exchanger (DHE) wells to prevent corrosion. They also expressed considerable concern about the use of oil in production well pumps since the fluids pumped would be injected. Oregon (and Idaho) prohibit the use of oil-lubricated pumps for public water supplies except in certain situations where non-toxic food-grade lubricants are used. Since enclosed-lineshaft oil-lubricated pumps are the mainstay of direct-use pumping equipment, the potential for restricting their use became a concern to the Geo-Heat Center staff. An investigation into alternative pump lubrication schemes and development of rebuttals to potential restrictions was proposed and approved as a contract task. (SM)

  2. Regulating vacuum pump speed with feedback control

    International Nuclear Information System (INIS)

    Ludington, D.C.; Aneshansley, D.J.; Pellerin, R.; Guo, F.

    1992-01-01

    Considerable energy is wasted by the vacuum pump/motor on dairy farms. The output capacity (m 3 /min or cfm) of the vacuum pump always exceeds the capacity needed to milk cows and wash pipelines. Vacuum pumps run at full speed and load regardless of actual need for air. Excess air is admitted through a controller. Energy can be saved from electrical demand reduced by regulating vacuum pump speed according to air based on air usage. An adjustable speed drive (ASD) on the motor and controlled based upon air usage, can reduce the energy used by the vacuum pump. However, the ASD unit tested could not maintain vacuum levels within generally accepted guidelines when air usage changed. Adding a high vacuum reserve and a dual vacuum controller between the vacuum pump and the milking pipeline brought vacuum stability within guidelines. The ASD/dual vacuum system can reduce energy consumption and demand by at least 50 percent during milking and provide better vacuum stability than conventional systems. Tests were not run during washing cycles. Using 1990 costs and only the energy saved during milking, the simple payback on investment in new equipment for a 5 hp motor, speed controller and vacuum regulator would be about 5 years

  3. Propuesta de incorporación del Segmento Pymes en las operaciones de crédito de la Cooperativa de Ahorro y Crédito 29 de Octubre

    OpenAIRE

    Ríos Páliz, Cristina Araceli

    2015-01-01

    En el proyecto que se presenta a continuación permite aplicar una metodología de análisis que brinde a la Cooperativismo de Ahorro y Crédito “29 de Octubre”, incorporar operaciones de crédito del segmento Comercial Pymes a su cartera de crédito cumpliendo lo establecido por la Superintendencia de Bancos, normativa que será transitoria para la Superintendencia de Economía Popular y Solidaria hasta que defina sus políticas de control y seguimiento para las Cooperativas de Ahorro y Crédito por ...

  4. Incidencia del modelo de otorgamiento de cartera en la gestión del riesgo de crédito de la cooperativa de ahorro y crédito Bola Amarilla de la ciudad de Ibarra

    OpenAIRE

    Ayala Pupiales, Sandra Maribel

    2017-01-01

    Evaluar la incidencia del modelo de otorgamiento de cartera en la gestión del riesgo de crédito de la cooperativa de ahorro y crédito Bola Amarilla de la ciudad de Ibarra. El presente trabajo proporciona estrategias, políticas y procedimientos con el fin de dar cumplimiento a las resoluciones emitidas por el órgano de supervisión y control para las cooperativas de ahorro y crédito Superintendencia de Economía Popular y Solidaria del Ecuador y la Junta Política de Regulación Financiera y Mo...

  5. Diseño de un sistema de gestión de seguridad de la información para Cooperativas de Ahorro y Crédito en base a la norma ISO 27001

    OpenAIRE

    Mantilla Guerra, Aníbal Rubén

    2009-01-01

    209 hojas : ilustraciones, 29 x 21 cm + CD-ROM 2254 En esta Tesis se diseñó un Sistema de Gestión de Seguridad de la Información para Cooperativas de Ahorro y Crédito, en base a la norma ISO 27001, la Ley de la Superintendencia de Bancos y Seguros, la Ley de Cooperativas de Ahorro y Crédito, considerando además, su evolución y problemática en el Sistema Financiero Nacional. De manera metodológica, científica y objetiva, se muestra como identificar, evaluar y gestionar el riesgo, en Coopera...

  6. Aplicación del impuesto a las transacciones financieras ITF y su incidencia en el servicio de ahorro del Banco de la Nación Región Puno 2004 - 2007.

    OpenAIRE

    Caceres Quispe, Hector Omar

    2010-01-01

    El presente trabajo de investigación titulado "APLICACIÓN DEL IMPUESTO A LAS TRANSACCIONES FINANCIERAS ITF Y SU INCIDENCIA EN EL SERVICIO DE AHORRO DEL BANCO DE LA NACIÓN REGION PUNO 2004-2007". Tiene como objetivo general determinar la incidencia del Impuesto a las Transacciones Financieras- ITF, en el servicio de ahorro del Banco de la Nación Región Puno. Los impuestos se obtienen de los ingresos generados en la economía, tanto por la interacción de las personas como por las empresas (en ac...

  7. Desarrollo de un manual de auditoría informática aplicado a Cooperativas de Ahorro y Crédito

    OpenAIRE

    Sarango Ontaneda, Carlos Alberto

    2013-01-01

    La auditoría informática es una función (en ocasiones un servicio) que apoya al trabajo de las unidades de auditoría interna de las Cooperativas de Ahorro y Crédito. Sin embargo, el trabajo a realizarse exige que los profesionales en auditoría informática cumplan con ciertas normas y requerimientos tanto legales como profesionales. El uso de marcos de buenas prácticas, análisis de riesgos y la observación de las normas de auditoría son fundamentales para el desarrollo de las evaluaciones de ...

  8. Propuesta de un plan estratégico de marketing para la Cooperativa de Ahorro y Crédito Artesanal de la ciudad de Cuenca

    OpenAIRE

    Salazar Centeno, Sandra Elizabeth; Toledo Solano, Miriam Alexandra

    2008-01-01

    La presente tesina, constituye un Plan Estratégico de Marketing para la Cooperativa de Ahorro y Crédito "Artesanal", orientado a contribuir con el desarrollo y bienestar para sus socios. Hoy en día las empresas deben ser proactivas y adelantarse a las necesidades del mercado, esto ayudará a mejorar su imagen, pero para esto, es importante contar con la filosofía empresarial, es decir el tener establecido cual es el norte de le entidad financiera, determinar las metas, objetivos institucion...

  9. Diagnóstico al sistema de control interno del área contable Cooperativa Nacional Educativa de Ahorro y Crédito "COONFIE"

    OpenAIRE

    Quesada Sánchez, Iván Darío; Calderón Gómez, Ramsés Camilo; Saavedra Pinzón, Miguel Antonio

    2013-01-01

    Presenta el resultado del estudio de evaluación sobre la aplicación y el desarrollo del sistema de control interno, en el área Contable de la Cooperativa Nacional Educativa de Ahorro y Crédito “COONFIE”. Así mismo se busca medir la utilización que ha hecho dicha entidad de la metodología empleada para inspección y vigilancia, el cual ha proporcionado herramientas y acciones complementarias en las entidades aportando desarrollo y crecimiento

  10. Análisis de un plan de ahorro energético implementando sistemas fotovoltaicos para los modelos de vivienda propuestos por el gobierno nacional

    OpenAIRE

    Quinto Ayovi, Marlon Jamil; Cadena Avila, Diego Alberto

    2016-01-01

    En el siguiente artículo se muestran los diseños de los sistemas fotovoltaicos que se desean implementar a las viviendas modelos propuestas por el gobierno nacional con la finalidad de obtener un ahorro energético a mediano o largo plazo utilizando fuentes de energías renovables como lo es el sol. Se procede a realizar dos escenarios, en el primero escenario se consideran todas las cargas de la vivienda modelo y en el segundo escenario se considera como carga solo a la cocina de inducción, en...

  11. Evaluation of energy saving in large scale projects in domestic lighting; Evaluacion del ahorro de energia en proyectos de gran escala en alumbrado domestico

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Adrian [Comision Federal de Electricidad, Mexico, D.F. (Mexico)

    2001-07-01

    The present work shows the methodology and the necessary parameters are indicated to evaluate the energy saving and the reduction of power demand obtained, by the large scale projects of substitution of incandescent lamps by compact, circular fluorescent and globe type lamps in the domestic sector. [Spanish] El presente trabajo muestra la metodologia y se indican los parametros necesarios para evaluar el ahorro de energia y reduccion de la demanda de potencia obtenidos, por los proyectos de gran escala de sustitucion de focos incandescentes por lamparas fluorescentes compactas, circulares y tipo globo en el sector domestico.

  12. Cost-Benefit of the energy saving in the bioclimatic designs; Costo-Beneficio del ahorro de energia en los disenos bioclimaticos

    Energy Technology Data Exchange (ETDEWEB)

    Lopez P, J. Manuel A. [Doble Dos Soluciones de Negocios, S.A. de C.V., Mexico, D.F. (Mexico); Morillon G, David; Rodriguez V, Luis [Instituto de Ingenieria de la UNAM, Mexico, D.F. (Mexico)

    1999-07-01

    Tools and criteria for the Cost-Benefit analysis from the energy saving in bioclimatic designs (BD) are presented, for which, a reference project is established and the costs and benefits of energy saving in BD with base in that project are evaluated. A case study is presented taking as reference the traditional design of the air conditioning of a building and with this base the estimation of cost-benefit of the same building is made, but with passive systems. The tools used are those that allow to consider related resources such as time and money; in that sense, are used criteria such as: Present value (PV), Equivalent Annual Cost (EAC) and the Cost of the Conserved Energy (CCE). The costs related to the construction, maintenance and operation of the design are taken into account. The differences between the reference design and the BD, established from the application of these criteria, allow to evaluate the economic margin of the BD as far as operation and maintenance is concerned. Finally the CCE of the bioclimatic measures is evaluated as an initiative of energy saving and the present value is calculated of the energy saving in the entire useful life of a bioclimatic design. [Spanish] Se presentan herramientas y criterios para el analisis Costo-Beneficio del ahorro de energia en disenos bioclimaticos (DB), para lo cual, se establece un proyecto de referencia y se evaluan los costos y beneficios del ahorro de energia en DB con base en ese proyecto. Se presenta el estudio de un caso tomando como referencia el dise tradicional de la climatizacion de un edificio y con base en este, se realiza la estimacion de costos y beneficios del mismo edificio, pero con sistemas pasivos. Las herramientas usadas, son aquellas que permiten considerar recursos relacionados como son tiempo y dinero; en ese sentido, se usan criterios como: Valor Presente (VP), Costo Anual Equivalente (CAE) y el Costo de la Energia Conservada (CEC). Se toman en consideracion los costos relacionados

  13. Planeamiento estratégico de las cajas municipales de ahorro y crédito de la Región Junín

    OpenAIRE

    Corilla Ruiz, Mariella; Julcarima Iñigo, Gilmar; Meneses Galindez, Carolina; Rodríguez Rivera, Franchesca

    2017-01-01

    La presente tesis desarrolla un planeamiento estratégico, con el propósito de que las Cajas Municipales de Ahorro y Crédito de la región Junín, se mantengan para el año 2022 como líderes del sector microfinanciero dentro de esta región, mediante la generación de soluciones financieras eficientes y eficaces basadas en incrementar la inclusión y educación financiera, la responsabilidad social y el cuidado del medio ambiente. Así mismo, el presente trabajo tiene por finalidad aume...

  14. Administración estratégica y gobernabilidad en las cooperativas de ahorro y crédito del cantón Portoviejo

    OpenAIRE

    Dianexy Viviana Carreño

    2014-01-01

    Las Cooperativas de Ahorro y Crédito (CAC’s) tienen una activa participación en el crecimiento y desarrollo económico del Ecuador, lo que permite desarrollar un estudio en la provincia de Manabí, tomando una muestra deliberada en el cantón Portoviejo, que concentra el 40% de las cooperativas que operan en la provincia; se utilizó la encuesta como técnica de recolección de datos, y se aplicó a los gerentes, presidentes de los Consejos de Administración y de vigilancia de diez CAC’s; A modo de ...

  15. De Cajas de Ahorro a sociedades capitalistas y Fundaciones un nuevo enfoque en la gestión y aplicación de la Obra Social

    OpenAIRE

    Aranda Ruiviejo, Antonio Carlos; Sotomayor Morales, Eva

    2017-01-01

    El presente trabajo se ha desarrollado con la finalidad de analizar las estrategias emprendidas por las nuevas Fundaciones surgidas tras el proceso de reestructuración del sector de las Cajas de Ahorro para garantizar la sostenibilidad de la Obra Social que anteriormente venían realizando estas entidades. Para ello se realiza un estudio de carácter descriptivo y explorativo que comprende un horizonte temporal de diez años y en el que se contrastan planteamientos anteriores y posteriores a los...

  16. Propuesta para la Incorporación del Concepto y la Estructuración del Área de Sostenibilidad en el Fondo Nacional del Ahorro

    OpenAIRE

    Diazgranados Muñoz, Ana María; Merlano Uribe, María Paula; Zamora Ramírez, Judith Andrea

    2014-01-01

    En el contexto actual en el que las organizaciones buscan generar acciones que respondan por el impacto que tienen sus actividades y decisiones en su entorno más próximo, se realiza un propuesta de incorporación del concepto de la Responsabilidad Social Empresarial (RSE) para el Fondo Nacional del Ahorro (FNA) con el fin de que la entidad involucre dentro de sus procesos acciones socialmente responsables y a su vez contribuya con el desarrollo sostenible. El documento Propuesta Para La ...

  17. El capital social y su tratamiento en las entidades en las entidades de ahorro y crédito popular sobre la base de la normativa contable internacional

    Directory of Open Access Journals (Sweden)

    Luis Carlos Gámez Adame

    2013-03-01

    Full Text Available Las Entidades de Ahorro y Crédito Popular (Cooperativas constituyen un segmento importante dentro de los servicios financieros que se prestan en diferentes países y que han tenido un desarrollo vertiginoso al satisfacer demandas y necesidades de numerosas masas poblacionales.Se presentan algunas consideraciones asociadas al tratamiento del capital social en estas entidades sobre la base de la normatividad contable internacional vigente y donde a criterio de los autores existen una serie de incongruencias a las que hay que darles solución.

  18. The effect of pump cavitation on the design of the primary pumps for C.F.R

    International Nuclear Information System (INIS)

    Worster, R.C.

    1976-01-01

    In the design appraisal of the sodium pumps for the primary circuit of the proposed 1300 MW(e) CFR it has been recognised that cavitation, its effects and its control, is the outstanding hydraulic design problem. Careful consideration of this problem and of the possible effects of pump cavitation on the performance of other reactor systems has led to the conclusion that it is more prudent at present to specify pumps with zero cavitation at normal full speed operating conditions. Under abnormal operation it may be necessary to reduce the pumps' speed to prevent cavitation in the pumps or associated equipment. The principal reasons for this decision were uncertainties concerning the possibility of erosion due to limited cavitation in sodium and the possibility of pump cavitation noise interfering with acoustic detection of malfunctioning of reactor components or of boiling in the reactor core

  19. Technical and Economic Working Domains of Industrial Heat Pumps: Part 1 - Vapour Compression Heat Pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Jensen, Jonas Kjær; Markussen, Wiebke Brix

    2014-01-01

    A large amount of operational and economic constraints limit the applicability of heat pumps operated with natural working fluids. The limitations are highly dependent on the integration of heat source and sink streams. An evaluation of feasible operating conditions is carried out considering...... the constraints of available refrigeration equipment and a requirement of a positive Net Present Value of the investment. The considered sink outlet temperature range is from 40 °C to 140 °C, but for the heat pumps considered in this paper, the upper limit is 100 °C. Five heat pumps are studied. For each set...... of heat sink and source temperatures the optimal solution is determined. At low sink temperature glide R717 heat pumps show best performance, while at higher sink glide transcritical R744 may become important. In a second paper, the results of the VCHP are compared to a similar study considering...

  20. PROMSYS, Plant Equipment Maintenance and Inspection Scheduling

    International Nuclear Information System (INIS)

    Morgan, D.L.; Srite, B.E.

    1986-01-01

    1 - Description of problem or function: PROMSYS is a computer system designed to automate the scheduling of routine maintenance and inspection of plant equipment. This 'programmed maintenance' provides the detailed planning and accomplishment of lubrication, inspection, and similar repetitive maintenance activities which can be scheduled at specified predetermined intervals throughout the year. The equipment items included are the typical pumps, blowers, motors, compressors, automotive equipment, refrigeration units, filtering systems, machine shop equipment, cranes, elevators, motor-generator sets, and electrical switchgear found throughout industry, as well as cell ventilation, shielding, containment, and material handling equipment unique to nuclear research and development facilities. Four related programs are used to produce sorted schedule lists, delinquent work lists, and optional master lists. Five additional programs are used to create and maintain records of all scheduled and unscheduled maintenance history. 2 - Method of solution: Service specifications and frequency are established and stored. The computer program reviews schedules weekly and prints, on schedule cards, instructions for service that is due the following week. The basic output from the computer program comes in two forms: programmed-maintenance schedule cards and programmed-maintenance data sheets. The data sheets can be issued in numerical building, route, and location number sequence as equipment lists, grouped for work assigned to a particular foreman as the foreman's equipment list, or grouped by work charged to a particular work order as the work-order list. Data sheets grouped by equipment classification are called the equipment classification list

  1. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  2. Variations in battery life of a heart-lung machine using different pump speeds, pressure loads, boot material, centrifugal pump head, multiple pump usage, and battery age.

    LENUS (Irish Health Repository)

    Marshall, Cornelius

    2012-02-03

    Electrical failure during cardiopulmonary bypass (CPB) has previously been reported to occur in 1 of every 1500 cases. Most heart-lung machine pump consoles are equipped with built-in battery back-up units. Battery run times of these devices are variable and have not been reported. Different conditions of use can extend battery life in the event of electrical failure. This study was designed to examine the run time of a fully charged battery under various conditions of pump speed, pressure loads, pump boot material, multiple pump usage, and battery life. Battery life using a centrifugal pump also was examined. The results of this study show that battery life is affected by pump speed, circuit pressure, boot stiffness, and the number of pumps in service. Centrifugal pumps also show a reduced drain on battery when compared with roller pumps. These elements affect the longevity and performance of the battery. This information could be of value to the individual during power failure as these are variables that can affect the battery life during such a challenging scenario.

  3. Electrokinetic pumps and actuators

    International Nuclear Information System (INIS)

    Phillip M. Paul

    2000-01-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps

  4. Electrokinetic pumps and actuators

    Energy Technology Data Exchange (ETDEWEB)

    Phillip M. Paul

    2000-03-01

    Flow and ionic transport in porous media are central to electrokinetic pumping as well as to a host of other microfluidic devices. Electrokinetic pumping provides the ability to create high pressures (to over 10,000 psi) and high flow rates (over 1 mL/min) with a device having no moving parts and all liquid seals. The electrokinetic pump (EKP) is ideally suited for applications ranging from a high pressure integrated pump for chip-scale HPLC to a high flow rate integrated pump for forced liquid convection cooling of high-power electronics. Relations for flow rate and current fluxes in porous media are derived that provide a basis for analysis of complex microfluidic systems as well as for optimization of electrokinetic pumps.

  5. Environmental impact of the programs of substitution of room type air conditioning equipment; Impacto ambiental de los programas de sustitucion de equipos de aire tipo cuarto

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon Aleman, Jose Mauricio [OLADE, Quito (Ecuador)

    2002-09-01

    The present article approaches in a general way the relation that exists between the environment and the saving of electrical energy, especially in the Programs of Demand Side Management (DSM). In particular form the potential environmental impacts are described, derived of the use and the discard of the room type air conditioning equipment, goes deep into the characteristics of their cooling fluids, as well as in the relation that these keep with the protocols of Montreal and Kyoto. Finally, this article comments the incidence which have, the manufacturers as the institutions that implement DSM programs, on the environmental part of the programs of substitution of room type air conditioning equipment. In addition it is briefly described, the pilot program developed by Fideicomiso para el Ahorro de Energia Electrica (FIDE) as a successful case. [Spanish] En forma general, el presente articulo aborda la relacion que existe entre el medio ambiente y el ahorro de energia electrica, especialmente en los Programas de Administracion por el Lado de la Demanda (ALD). En forma particular se describen los impactos ambientales potenciales, derivados del uso y desecho de los equipos de aire acondicionado tipo cuarto, se ahonda en las caracteristicas de sus refrigerantes, asi como en la relacion que estos guardan con los protocolos de Montreal y Kioto. Finalmente, se comenta la incidencia que tienen, tanto los fabricantes como las instituciones que implementan programas de ALD, sobre la parte ambiental de los programas de sustitucion de equipos de aire acondicionado tipo cuarto. Ademas se describe brevemente, el programa piloto desarrollado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE) como un caso exitoso.

  6. Energy saving with speed variators; Ahorro de energia con variadores de velocidad

    Energy Technology Data Exchange (ETDEWEB)

    Dolores Anguiano, Ramses; Dolores Vazquez, Raul [Cementos Cruz Azul, Hidalgo (Mexico)

    2005-07-01

    The cement plant Cruz Azul S.C.L. is located in the center of the Mexican republic at 70 km north of the capital. Nowadays the Direction of Cementos Cruz Azul has implemented measures allowing to reduce their production costs. The optimization department found a great area of opportunity at the ventilators of the plant. The ventilators are used in different stages of the process and their flow was normally controlled by means of dampers -due to the high costs of the initial investment and that of maintenance of the speed variation technology which in its majority used direct current equipments. In this case it existed the possibility of making a successful application in two large ventilators, with motors of 1000 HP fed in medium tension (4160 v) in our calcination unit Num. 8. This document shows the development of this project from its initial analysis to its application and results. [Spanish] La planta de cemento Cruz Azul S.C.L. se encuentra localizada en el centro de la republica mexicana a 70 Km al norte de la capital. En estos momentos la direccion de cementos Cruz Azul ha implementado medidas que permitan reducir sus costos de produccion. El departamento de optimizacion encontro una gran area de oportunidad en los ventiladores de la planta. Los ventiladores son utilizados en distintas etapas del proceso y normalmente su flujo era controlado por medio de mamparas, debido a los altos costos como inversion inicial y de mantenimiento de la tecnologia de variacion de velocidad que en su mayoria utilizaba equipos de corriente directa. Para nuestro caso existia la posibilidad de realizar una aplicacion exitosa en dos ventiladores grandes, con motores de 1000 HP alimentados en media tension (4160 v), en nuestra unidad de calcinacion Num. 8. Este documento muestra el desarrollo de este proyecto desde su analisis inicial hasta su aplicacion y resultados.

  7. Detection of pump degradation

    International Nuclear Information System (INIS)

    Greene, R.H.; Casada, D.A.; Ayers, C.W.

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented

  8. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  9. The Causes and Prevention Measures of Stuck Pump Phenomenon of Rod-pumped Well in CBM Field

    Science.gov (United States)

    Yonggui, Mei

    2018-02-01

    In the process of CBM field exploitation, in order to realize the drainage equipment to work continuous stably, the article pays attention to study and solve the stuck pump problem, and aim of reducing reservoir damage and lowing production costs. Through coal particles stuck pump experiment and sediment composition analysis, we find out five primary cause of stuck pump phenomenon: sand from coal seam, sediment from ground, iron corrosion, iron scrap caused by eccentric wear, coal cake. According to stuck pump mechanism, the article puts forward 8 measures to prevent stuck pump phenomenon, and the measures are focused on technology optimization, operation management and drainage process control. After 7 years production practice, the yearly stuck pump rate has dropped from 8.9% to 1.2%, and the pump inspection period has prolonged 2 times. The experiment result shows that pure coal particles cannot cause stuck pump, but sand, scrap iron, and iron corrosion are the primary cause of stuck pump. The article study and design the new pipe string structure that the bottom of the pipe string is open. This kind of pipe string applied the sedimentation terminal velocity theory to solve the stuck pump phenomenon, and it can be widely used in CBM drainage development.

  10. Thermomechanical piston pump development

    Science.gov (United States)

    Sabelman, E. E.

    1971-01-01

    A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

  11. Pumps for nuclear industry

    International Nuclear Information System (INIS)

    Tanguy, L.

    1978-01-01

    In order to meet the requirements of nuclear industry for the transfer of corrosive, toxic, humidity sensitive or very pure gases, different types of pumps were developped and commercialized. Their main characteristics are to prevent pollution of the transfered fluid by avoiding any contact between this fluid and the lubricated parts of the machine, and to prevent a contamination of the atmosphere or of the fluid by a total tightness. Patellar pumps have been particularly developped because the metallic bellows are quite reliable and resistant in this configuration. Two types are described: patellar pumps without friction and barrel pumps whose pistons are provided with rings sliding in the cylinders without lubrication [fr

  12. Pump safety device

    International Nuclear Information System (INIS)

    Timmermans, Francis; Vandervorst, Jean.

    1981-01-01

    Safety device for longitudinally leak proofing the shaft of a pump in the event of the fracture of the dynamic seal separating the pump fluid high pressure chamber from the low pressure chamber. It is designed for fitting to the primary pumps of nuclear reactors. It includes a hollow cyclindrical piston located coaxially around the pump shaft and normally housed in a chamber provided for this purpose in the fixed housing of the dynamic seal, and means for moving this piston coaxially so as to compress a safety O ring between the shaft and the piston in the event of the dynamic seal failing [fr

  13. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  14. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1995-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  15. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  16. Electric power saving potential due to domestic refrigerators replacement; Potencial de ahorro de energia electrica por el reemplazo de refrigeradores domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de Energia Electrica (Mexico)]. E-mail: jose.peralta@cfe.gob.mx

    2006-04-15

    In Mexico the second most used electrical appliance is: refrigerator. Owing to its use, it would be a promising option for electric power saving. In Guadalajara, Reynosa and Tampico it was performed a study with the aim of launching a project to replace the old refrigerators with new ones which are more effective and less expensive. Since the refrigerators cost and the electrical invoicing saving, the electric appliance change is profitable. To expect with this replacement more than eight million of refrigerators manufactured before 1997 will be changed. [Spanish] El refrigerador es el segundo electrodomestico mas utilizado a nivel nacional, esto permite que debido a su uso sea una opcion prometedora para el ahorro de energia electrica. Se hizo un estudio en Guadalajara, Reynosa y Tampico con el fin de lanzar un proyecto para sustituir los refrigeradores viejos por unos nuevos que sean mas eficaces y menos costosos. Por el costo de los refrigeradores y el ahorro en la facturacion electrica, el cambio de electrodomestico es rentable, de esta manera se espera que los mas de ocho millones de refrigeradores fabricados antes de 1997 que existen en el pais sean cambiados.

  17. Performance of Wind Pump Prototype

    African Journals Online (AJOL)

    Mulu

    Mekelle University, Mekelle, Ethiopia (*mul_at@yahoo.com). ABSTRACT. A wind ... balanced rotor power and reciprocating pump, hence did not consider the effect of pump size. ... Keywords: Wind pump, Windmill, Performance testing, Pump efficiency, Pump discharge, ... Unfortunately, in rural places, where the houses are.

  18. Hot conditioning equipment conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    Bradshaw, F.W., Westinghouse Hanford

    1996-08-06

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

  19. Hot conditioning equipment conceptual design report

    International Nuclear Information System (INIS)

    Bradshaw, F.W.

    1996-01-01

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage

  20. Detection of pump degradation

    International Nuclear Information System (INIS)

    Casada, D.

    1994-01-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous spectral vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition: advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed

  1. Geothermal heat-pump systems of heat supply

    International Nuclear Information System (INIS)

    Vasil'ev, G.P.

    2004-01-01

    The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented [ru

  2. Normetex Pump Alternatives Study

    International Nuclear Information System (INIS)

    Clark, Elliot A.

    2013-01-01

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine, chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have varying

  3. Selection of fluids for tritium pumping systems

    International Nuclear Information System (INIS)

    Chastagner, P.

    1984-02-01

    The degradation characteristics of three types of vacuum pump fluids, polyphenyl ethers, perfluoropolyethers and hydrocarbon oils were reviewed. Fluid selection proved to be a critical factor in the long-term performance of tritium pumping systems and subsequent tritium recovery operations. Thermal degradation and tritium radiolysis of pump fluids produce contaminants which can damage equipment and interfere with tritium recovery operations. General characteristics of these fluids are as follows: polyphenyl ether has outstanding radiation resistance, is very stable under normal diffusion pump conditions, but breaks down in the presence of oxygen at anticipated operating temperatures. Perfluoropolyether fluids are very stable and do not react chemically with most gases. Thermal and mechanical degradation products are inert, but the radiolysis products are very corrosive. Most of the degradation products of hydrogen oils are volatile and the principal radiolysis product is methane. Our studies show that polyphenyl ethers and hydrocarbon oils are the preferred fluids for use in tritium pumping systems. No corrosive materials are formed and most of the degradation products can be removed with suitable filter systems

  4. Estimated potential of energy saving and reduction of the demand commercial buildings illumination; Potencial estimado de ahorro de energia y reduccion de la demanda en iluminacion de edificios comerciales

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Gomez, Victor Hugo; Morillon Galvez, David [Posgrado en Energetica de la DEPFI-UNAM, Mexico, D. F. (Mexico)

    1999-07-01

    In this paper the estimated energy saving potential in illumination, the energy end use and the technology used in commercial buildings of different use is analyzed. Estimation that departs from information of the Fideicomiso para el Ahorro de Energia (FIDE) demonstrative cases, presents the energy saving and the demand reduction in a sample of 29 buildings, among which are shopping malls, hospitals, schools, hotels, restaurants and public buildings in which energy saving programs have been carried out, with measures such as the cleaning of the luminaries and its replacement for more efficient ones. The average saving obtained is of 21.81%, in the following areas: illumination, air conditioning and others. In addition, in a sample of 4 buildings, it was observed that before applying the energy saving programs, two of them did not fulfill with the norm NOM-007-1995 (electric power density in interior lighting systems W/m{sup 2}) and later did fulfill the values and criteria of the norm. [Spanish] En el presente trabajo se analiza el potencial estimado de ahorro de energia en iluminacion, el uso final de la energia y la tecnologia empleada en edificios comerciales de uso distinto. Estimacion que parte de la informacion de los casos demostrativos del Fideicomiso para el Ahorro de Energia (FIDE), se presenta el ahorro y reduccion de la demanda en una muestra de 29 edificios, entre los que se tienen centros comerciales, hospitales, escuelas, hoteles, restaurantes y edificios publicos en los cuales se ha llevado a cabo programas de ahorro de energia, con medidas como la limpieza de las luminarias y su remplazo por otros mas eficientes. El ahorro promedio obtenido es de 21.81%, en las siguientes areas: iluminacion, aire acondicionado y otros. Ademas, en una muestra de 4 edificios, se observo que antes de aplicar los programas de ahorro de energia, dos no cumplian con la norma NOM-007-ENER-1995 (densidad de potencia electrica en alumbrado interior W/m{sup 2}) y

  5. BWR series pump recirculation system

    International Nuclear Information System (INIS)

    Dillmann, C.W.

    1992-01-01

    This patent describes a recirculation system for driving reactor coolant water contained in an annular downcomer defined between a boiling water reactor vessel and a reactor core spaced radially inwardly therefrom. It comprises a plurality of circumferentially spaced second pumps disposed in the downcomer, each including an inlet for receiving from the downcomer a portion of the coolant water as pump inlet flow, and an outlet for discharging the pump inlet flow pressurized in the second pump as pump outlet flow; and means for increasing pressure of the pump inlet flow at the pump inlet including a first pump disposed in series flow with the second pump for first receiving the pump inlet flow from the downcomer and discharging to the second pump inlet flow pressurized in the first pump

  6. High pressure liquid gas pump

    Science.gov (United States)

    Acres, R. L.

    1972-01-01

    Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.

  7. Benefits and applications of modular hydroelectric pumped storage

    International Nuclear Information System (INIS)

    Koebbe, R.S.

    1991-01-01

    This paper reports on hydroelectric pumped storage which is the only proven and most efficient technology available for energy storage. It is used by utilities to provide peak and intermediate power and to optimize overall system performance. Because of increased environmental and regulatory constraints, few acceptable sites, long schedules, and huge financial commitments, large conventional pumped storage plants, are now virtually impossible to build. As an alternative, small modular pumped storage, with project sizes ranging from 25 MW to 200 MW, was created to overcome the difficulties of conventional projects. The modular approach involves standardizing the elements of a pumped storage plant by utilizing specialized siting techniques and optimizing design, equipment, and construction. Compared with conventional pumped storage, the modular design can reduce cost and expedite schedule; reduce environmental concerns and permitting obstacles; and expand applications of energy storage on a utility's system

  8. Experience on vibration analysis of primary coolant pumps in Cirus

    International Nuclear Information System (INIS)

    Ullas, O.P.; Tilara, Manoj; Kharpate, A.V.

    2002-01-01

    Full text: 40 MW (thermal) CIRUS research reactor has been in operation for over four decades. During the major portion of its life almost all the major mechanical equipment operated continuously in a healthy condition. Since 1988 ageing related breakdown has been noticed in some of the critical components, PCW pumps being one of them. Vibration measurement and analysis is carried out on a routine basis as a part of conditioning monitoring programme. Ageing degradation of various components of the pump has been detected by such a performance monitoring programme. Conditioning monitoring has been found to be quite useful for scheduling of maintenance work on pumps

  9. Fast Flux Test Facility replacement of a primary sodium pump

    International Nuclear Information System (INIS)

    Krieg, S.A.; Thomson, J.D.

    1985-01-01

    The Fast Flux Test Facility is a 400 MW Thermal Sodium Cooled Fast Reactor operated by Westinghouse Hanford Company for the US Department of Energy. During startup testing in 1979, the sodium level in one of the primary sodium pumps was inadvertently raised above the normal height. This resulted in distortion of the pump shaft. Pump replacement was carried out using special maintenance equipment. Nuclear radiation and contamination were not significant problems since replacement operations were carried out shortly after startup of the Fast Flux Test Facility

  10. Operating states of PFBR-primary sodium pump

    International Nuclear Information System (INIS)

    Sreedharan, K.V.; Rao, A.S.L.K.; Raju, C.; Kale, R.D.

    1994-01-01

    The proposed 500 MWe Prototype Fast Breeder Reactor (PFBR), the design of which is in progress at the Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam will be equipped with four centrifugal sodium pumps each in its primary and secondary circuits. This paper discusses the various operating states of the primary pumps viz. (i) normal steady state (ii) transient state operation. The paper also discusses the safe limits on the pump operating speed and a few design basis incidents. (author). 1 ref., 2 figs., 3 tabs

  11. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  12. Self-sustaining nuclear pumped laser-fusion reactor experiment

    International Nuclear Information System (INIS)

    Boody, F.P.; Choi, C.K.; Miley, G.H.

    1977-01-01

    The features of a neutron feedback nuclear pumped (NFNP) laser-fusion reactor equipment were studied with the intention of establishing the feasibility of the concept. The NFNP laser-fusion concept is compared schematically to electrically pumped laser fusion. The study showed that, once a method of energy storage has been demonstrated, a self-sustaining fusion-fission hybrid reactor with a ''blanket multiplication'' of two would be feasible using nuclear pumped Xe F* excimer lasers having efficiencies of 1 to 2 percent and D-D-T pellets with gains of 50 to 100

  13. Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure.

    Science.gov (United States)

    Kawahito, Koji

    2013-09-01

    Although non-destructive and continuous monitoring is indispensable for long-term circulatory support with rotary blood pumps, a practical monitoring system has not yet been developed. The objective of this study was to investigate the possibility of detecting pump failure caused by thrombus formation through the monitoring of vibration signals. The data acquisition equipment included vibration pickups, a charge amplifier, vibration analysis systems, and exclusive hardware. A pivot-bearing centrifugal pump with a mock circuit was investigated for vibration analysis. To simulate the four common areas of thrombus formation, we used a piece of silicon attached to each of the following four locations: the total area of the bottom of the impeller, an eccentric shape on the bottom of the impeller, a circular shape around the shaft top, and an eccentric shape on the top of the impeller. Vibration signals were picked up, and the power spectrum density analysis was performed at pump rotational speeds of 2100, 2400, and 3000 rpm. In this study, pump failure could be detected, and the types of imitation thrombi could be determined. We conclude that vibration detection with a computerized analysis system is a potentially valuable diagnostic tool for long-term circulatory support with rotary blood pumps.

  14. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  15. ITER - torus vacuum pumping system remote handling issues

    International Nuclear Information System (INIS)

    Stringer, J.

    1992-11-01

    This report describes further design issues concerning remote maintenance of torus vacuum pumping systems options for ITER. The key issues under investigation in this report are flask support systems for valve seal exchange operations for the compound cryopump scheme and remote maintenance of a proposed multiple turbomolecular pump (TMP) system, an alternative ITER torus exhaust pumping option. Previous studies have shown that the overhead support methods for seal exchange flask equipment could malfunction due to valve/flask misalignment. A floor-mounted support system is described in this report. This scheme provides a more rigid support system for seal exchange operations. An alternative torus pumping system, based on the use of multiple TMPs, is studied from a remote maintenance standpoint. In this concept, centre distance spacing for pump/valve assemblies is too restrictive for remote maintenance. Recommendations are made for adequate spacing of these assemblies based on commercially-available 0.8 m and 1.0 m diameter valves. Fewer pumps will fit in this arrangement, which implies a need for larger TMPs. Pumps of this size are not commercially available. Other concerns regarding the servicing and storage of remote handling equipment in cells are also identified. (9 figs.)

  16. Electromagnetic pump technology

    International Nuclear Information System (INIS)

    Prabhakar, R.

    1994-01-01

    Fast Breeder Reactors have an important role to play in our nuclear power programme. Liquid metal sodium is used as the coolant for removing fission heat generated in fast reactors and a distinctive physical property of sodium is its high electrical conductivity. This enables application of electromagnetic (EM) pumps, working on same principle as electric motors, for pumping liquid sodium. Due to its lower efficiency as compared to centrifugal pumps, use of EM pumps has been restricted to reactor auxiliary circuits and experimental facilities. As part of our efforts to manufacture fast reactor components indigenously, work on the development of two types of EM pumps namely flat linear induction pump (FLIP) and annular linear induction pump (ALIP) has been undertaken. Design procedures based on an equivalent circuit approach have been established and results from testing a 5.6 x 10E-3 Cum/s (20 Cum/h) FLIP in a sodium loop were used to validate the procedure. (author). 7 refs., 6 figs

  17. Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

    Science.gov (United States)

    Lemoff, Asuncion V [Union City, CA; Lee, Abraham P [Irvine, CA

    2010-07-13

    A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

  18. Reconciliation of equipment flexibility effects on piping system dynamic response

    International Nuclear Information System (INIS)

    Geraets, L.H.

    1987-01-01

    Piping systems are connected to equipment; if the equipment cannot be considered as ''rigid'' relative to excitation frequencies, nozzle response spectra techniques, or equipment modeling techniques are used. If the equipment is considered rigid, a fixed anchor is assumed. However, occasionally after (seismic) dynamic analysis has been completed, tests or detailed equipment dynamic analyses demonstrate that the assumption of ''infinite stiff'' is questionable. This paper reviews several classes of equipment (pumps, vessels, reservoirs, heat exchangers), and the associated (piping stresses, support loads, equipment nozzle allowables). Significant divergences between design and ''as built'' results are shown (for heat exchangers in particular). The paper discusses the reconciliation process performed for a belgian PWR plant through the use of less conservative seismic damping data (Code Case N-411)

  19. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  20. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  1. Gas fired heat pumps

    International Nuclear Information System (INIS)

    Seifert, M.

    2006-01-01

    The condensing gas boiler is now state of the art and there is no more room for improvement in performance, technically speaking. The next logical step to improve the overall efficiency is to exploit ambient heat in combination with the primary source of energy, natural gas. That means using natural-gas driven heat pumps and gas-fired heat pumps. Based on this, the Swiss Gas Industry decided to set up a practical test programme enjoying a high priority. The aim of the project 'Gas-fired heat pump practical test' is to assess by field tests the characteristics and performance of the foreign serial heat pumps currently on the market and to prepare and promote the introduction on the market place of this sustainable natural-gas technology. (author)

  2. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  3. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  4. Pressurized Vessel Slurry Pumping

    International Nuclear Information System (INIS)

    Pound, C.R.

    2001-01-01

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air

  5. Mechanical vaccum pumps

    CERN Document Server

    Chew, A D

    2007-01-01

    This presentation gives an overview of the technology of contemporary primary and secondary mechanical vacuum pumps. For reference a brief history of vacuum and a summary of important and basic vacuum concepts are first presented.

  6. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.; Abdelghany, Mohamed A.; Elsayed, Mohannad Yomn; Elshurafa, Amro M; Salama, Khaled N.

    2014-01-01

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  7. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  8. GAS METERING PUMP

    Science.gov (United States)

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  9. JET pump limiter

    International Nuclear Information System (INIS)

    Sonnenberg, K.; Deksnis, E.; Shaw, R.; Reiter, D.

    1988-01-01

    JET plans to install two pump limiter modules which can be used for belt-limiter, inner-wall and X-point discharges and, also, for 1-2s as the main limiter. A design is presented which is compatible with two diagnostic systems, and which allows partial removal of the pump limiter to provide access for remote-handling operations. The high heat-flux components are initially cooled during a pulse. Heat is removed between discharges by radiation and pressure contacts to a water-cooled support structure. The pumping edge will be made of annealed pyrolytic graphite. Exhaust efficiency has been estimated, for a 1-d edge model, using a Monte-Carlo calculation of neutral gas transport. When the pump limiter is operated together with other wall components we expect an efficiency of ≅ 5% (2.5 x 10 21 part/s). As a main limiter the efficiency increases to about 10%. (author)

  10. Types of Breast Pumps

    Science.gov (United States)

    ... called a bicycle horn pump, consists of a hollow rubber ball attached to a breast-shield. Some ... and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 1-888-INFO-FDA (1-888- ...

  11. Proceedings of the 22 National seminar on the rational an efficient use of energy and exposition of equipment and services. [Selected Papers]; 22. Seminario nacional sobre el uso racional y eficiente de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This document contains the proceedings of the 22 national seminar on the rational and efficient use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), in Mexico, D.F., from the 25 to the 29 of August of 2003. This Seminar covered subjects such as: Energy saving in the power sector, power efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in constructions, transport, utilization of renewable energies and the environment. [Spanish] Este documento contiene la memoria tecnica del 22 seminario nacional sobre el uso racional y eficiente de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F., del 25 al 29 de agosto de 2003. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables y ambiente.

  12. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  13. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  14. Resorption heat pump

    International Nuclear Information System (INIS)

    Vasiliev, L.L.; Mishkinis, D.A.; Antukh, A.A.; Kulakov, A.G.; Vasiliev, L.L.

    2004-01-01

    Resorption processes are based on at least two solid-sorption reactors application. The most favorable situation for the resorption heat pumps is the case, when the presence of a liquid phase is impossible. From simple case--two reactors with two salts to complicated system with two salts + active carbon fiber (fabric) and two branch of the heat pump acting out of phase to produce heat and cold simultaneously, this is the topic of this research program

  15. Portable photovoltaic irrigation pumps

    Energy Technology Data Exchange (ETDEWEB)

    Furber, J. D.

    1980-07-01

    Experiences in developing a solar-powered irrigation pump to meet the needs of poor farmers in developing nations are summarized. The design which evolved is small and portable, employing a high-efficiency electric pump, powered by photovoltaic panels. Particular emphasis is placed on how the system works, and on early field problems experienced with the first prototypes. The resolution of these problems and the performance of actual systems in various countries is presented and user responses are noted.

  16. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.

    1984-05-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  17. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.; California Univ., Los Angeles

    1984-01-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6 MW of auxiliary neutral beam heating. Experiments have also been performed with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scrape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a regime may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this 'Z-mode' of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described. (orig.)

  18. Laser pumped lasers for isotope separation

    International Nuclear Information System (INIS)

    Fry, S.M.

    1976-01-01

    A study of the isotope separation laser requirements reveals that high pressure polyatomic molecular gas laser pumped lasers can attain the necessary characteristics including tunability, energy output, pulse width, and repetition rate. The results of a search, made for molecules meeting the appropriate requirements for one of several pump schemes utilizing a CO 2 laser and with output in the 12 μm or 16μm wavelength range, are presented. Several methods of pumping are reviewed and two novel pump schemes are presented. A laser pumped laser device design is given, and operation of this device and associated diagnostic equipment is confirmed by repeating experiments in OCS and NH 3 . The results of OCS laser experiments show that an improvement in pump rate and output per unit length is obtained with the device, using a wedged transverse pumping scheme. A new multi-line laser system in NH 3 pumped by a TEA CO 2 laser is reported. More than forty transitions spanning the wavelength range of 9.2 to 13.8 μm are observed and identified. A strong output at 12.08 μm is one of the closest lines yet found to the required laser isotope separation wavelength. Far infrared emission near 65 μm is observed and is responsible for populating levels which lase in pure ammonia near 12.3 μm. Buffer gas (e.g., N 2 or He) pressures of approximately 40--800 torr cause energy transfer by collision-induced rotationaltransitions from the pumped antisymmetric to the lasing symmetric levels in the nu 2 = 1 band of ammonia. Most of the observed lines are aP(J,K) transitions which originate from the nu 2 /sup s/ band. Measurements of the pressure dependence of the laser output shows that some lines lase at pressures greater than one atmosphere. Transient behavior of the 12.08 μm line is calculated from a simplified analytic model and these calculations are compared to the experimental results

  19. Energy efficiency in pumps

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Durmus; Yagmur, E. Alptekin [TUBITAK-MRC, P.O. Box 21, 41470 Gebze, Kocaeli (Turkey); Yigit, K. Suleyman; Eren, A. Salih; Celik, Cenk [Engineering Faculty, Kocaeli University, Kocaeli (Turkey); Kilic, Fatma Canka [Department of Air Conditioning and Refrigeration, Kocaeli University, Kullar, Kocaeli (Turkey)

    2008-06-15

    In this paper, ''energy efficiency'' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems. (author)

  20. Energy efficiency in pumps

    International Nuclear Information System (INIS)

    Kaya, Durmus; Yagmur, E. Alptekin; Yigit, K. Suleyman; Kilic, Fatma Canka; Eren, A. Salih; Celik, Cenk

    2008-01-01

    In this paper, 'energy efficiency' studies, done in a big industrial facility's pumps, are reported. For this purpose; the flow rate, pressure and temperature have been measured for each pump in different operating conditions and at maximum load. In addition, the electrical power drawn by the electric motor has been measured. The efficiencies of the existing pumps and electric motor have been calculated by using the measured data. Potential energy saving opportunities have been studied by taking into account the results of the calculations for each pump and electric motor. As a conclusion, improvements should be made each system. The required investment costs for these improvements have been determined, and simple payback periods have been calculated. The main energy saving opportunities result from: replacements of the existing low efficiency pumps, maintenance of the pumps whose efficiencies start to decline at certain range, replacements of high power electric motors with electric motors that have suitable power, usage of high efficiency electric motors and elimination of cavitation problems

  1. Design aspects and conservation of roads in the saving of energy; Aspectos de diseno y conservacion de carreteras en el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Cajun, Carlos S; Aguerrebere Salido, Roberto [Instituto Mexicano del Transporte, Queretaro (Mexico)

    1993-12-31

    In this paper the effects that on the fuel consumption the roads have for their slopes and roughness are presented. A mathematical model is presented which shows the relationship between the slope, the roughness coefficient and the required power to overcome the corresponding resistance; the former in order to predict the fuel consumption and therefore, the potential level of energy saving corresponding to this item. [Espanol] En este trabajo se presentan los efectos que sobre consumo de combustible se tienen, debido a las pendientes y rugosidades de las carreteras. Se presenta un modelo matematico que muestra la relacion entre la pendiente, el coeficiente de rodamiento y la potencia requerida para vencer las resistencias correspondientes; lo anterior con el fin de predecir el consumo de combustible y, por lo tanto, los niveles potenciales de ahorro de energia correspondientes a este rubro.

  2. Implementacion del modelo Lean Service en el proceso de recaudo de la Cooperativa de Ahorro y Crédito Fincomercio ltda

    Directory of Open Access Journals (Sweden)

    Jonny Gavilán

    2016-12-01

    Full Text Available El presente trabajo forma parte de la tesis de maestría, para optar al título de Magister en Ingeniería Industrial de la Universidad Distrital Francisco José de Caldas. El cual se basó fundamentalmente en el diseño e implementación del modelo Lean Service para el proceso de recaudo de la Cooperativa de Ahorro y Crédito Fincomercio Ltda. En este marco de referencia, la presente investigación de tipo Descriptivo – Explicativo consistirá en la aplicación de la metodología Lean Service para el mejoramiento del proceso de recaudo de la Cooperativa.

  3. Design aspects and conservation of roads in the saving of energy; Aspectos de diseno y conservacion de carreteras en el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Cajun, Carlos S.; Aguerrebere Salido, Roberto [Instituto Mexicano del Transporte, Queretaro (Mexico)

    1992-12-31

    In this paper the effects that on the fuel consumption the roads have for their slopes and roughness are presented. A mathematical model is presented which shows the relationship between the slope, the roughness coefficient and the required power to overcome the corresponding resistance; the former in order to predict the fuel consumption and therefore, the potential level of energy saving corresponding to this item. [Espanol] En este trabajo se presentan los efectos que sobre consumo de combustible se tienen, debido a las pendientes y rugosidades de las carreteras. Se presenta un modelo matematico que muestra la relacion entre la pendiente, el coeficiente de rodamiento y la potencia requerida para vencer las resistencias correspondientes; lo anterior con el fin de predecir el consumo de combustible y, por lo tanto, los niveles potenciales de ahorro de energia correspondientes a este rubro.

  4. Evaluation of the energy saving potential in illumination using presence sensors; Evaluacion del potencial de ahorro de energia en iluminacion utilizando sensores de presencia

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Eslava, Alejandro [Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1999-07-01

    The analysis and the evaluation of the energy saving that would provide a system of illumination controlled by sensors of presence in an enclosure with low transit, evaluating the economic profitability of the system is presented. The data, from which the analysis is sustained and the results are deducted, coming from the use and installation of a timer in the area. [Spanish] Se presenta el analisis y la evaluacion de los ahorros de energia que suministraria un sistema de iluminacion controlado por sensores de presencia en un recinto con bajo transito, evaluando la rentabilidad economica del sistema. Los datos, a partir de los cuales se sustenta el analisis y se deducen los resultados, provienen de la utilizacion e instalacion de un contador de tiempo de uso en el recinto.

  5. Evaluation of saving measurements and energetic efficiency in air-conditioning systems; Evaluacion de medidas de ahorro y eficiencia energetica en sistemas de climatizacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez Lombard, L [Asociacion de Investigacion y Cooperacion de Andalucia (Spain); Ortiz, J [Building Research Establishment (United Kingdom); Riviere, P [Armines-ecole des mines de Paris (France)

    2006-04-15

    Buildings require an adequate air conditioning to offer workers a labor environment where there is thermal comfort. A study was performed in three different European places which count on several climates. The conclusion was the following: in order to analyze the energy efficiency in edifications it is fundamental the simulation tools use with the purpose of calculating the consumption and evaluating the saving measurements. [Spanish] Los edificios requieren de una climatizacion adecuada para que los que ahi operan puedan hacerlo dentro de un ambiente laboral donde exista el confort termico. Se llevo a cabo un estudio en tres lugares de Europa poseedores de diferentes climas y se concluyo que para poder analizar la eficiencia energetica de climatizacion en las edificaciones es imprescindible el uso de herramientas de simulacion con el proposito de calcular el consumo y evaluar las medidas de ahorro.

  6. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the

  7. Particle exhaust studies in Tore Supra with a pump limiter

    International Nuclear Information System (INIS)

    Klepper, C.C.; Haste, G.R.; Horton, L.D.; Mioduszewski, P.K.; Uckan, T.; Bonnel, P.; Bruneau, J.L.; Chatelier, M.; Gil, C.; Grisolia, C.; Loarer, T.; Martin, G.; Pegourie, B.; Rodriguez, L.; Watkins, J.G.

    1990-01-01

    The aim of the Tore Supra pump limiter program is to study particle exhaust with a pump limiter system in long-pulse discharges with continuous pellet fueling and strong auxiliary heating. The pump limiter system consists of six vertical modules, located at the bottom of the machine, and one horizontal module at the outer midplane. The results presented here were obtained with the horizontal module only. This module was equipped with two titanium pumps with a total pumping speed of 100000 L/s. The instrumentation of the limiter included pressure gauges, a residual gas analyzer, Langmuir probes, a spectrometer viewing the neutralizer plate for H α and impurity measurements, and water calorimeters. All diagnostics have been commissioned and are operational. Initial results were obtained in low-density discharges, with no gas puffing during the shot. While only a modest effect on the plasma density was observed, large exhaust fluxes were measured in the pump limiter. The most likely source of this gas was outgassing of the graphite walls. Straightforward particle balance between the plasma efflux and the pump limiter exhaust, as applied in previous pump limiter experiments, did not apply. The core plasma and the edge plasma seemed to be largely decoupled and a multi-layer model is being developed to explain the experimental results. (orig.)

  8. Creación de un marco de control para la administración del riesgo operativo relacionado con la tecnologias de la información como modelo para las cooperativas de ahorro y crédito del Ecuador

    OpenAIRE

    Brito Domínguez, Jimmy Arturo; Echeverria Briones, Pedro Fabricio

    2009-01-01

    Creación de un marco de control para la administración del riesgo operativo relacionado con la tecnologías de la informacion como modelo para las cooperativas de ahorro y credito del Ecuador Creación de un marco de control para la administración del riesgo operativo relacionado con la tecnologías de la informacion como modelo para las cooperativas de ahorro y credito del Ecuador

  9. Experiences on energy saving in Comision Federal Electricidad (CFE) buildings; Experiencias de ahorro de energia en edificios de la Comision Federal de Electricidad (CFE)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Velasco, Jorge E [Comision Federal de Electricidad (CFE) (Mexico)

    2005-07-01

    This document describes the developed saving projects in buildings and generating power stations in 2004 by the Comision Federal de Electricidad (CFE). The projects considered are: buildings of the oficinas nacionales, Divisions of distribution office buildings, office buildings of production regions, construction deputy manager's office building, buildings of transmission and transformation, generating power stations, investments and savings of the projects in oficinas nacionales, divisions of distribution and construction subdivision buildings. From these projects the ones concluded in the 2004 were: Distribution Divisions, Gulf-Center Division, Center-West Distribution Division. The developing projects of 2005: oficinas nacionales, distribution divisions, Construction Subdivision, Generating Power Stations, Transmission Areas and office buildings. And finally, the projects concluded in the 2005 are the distribution divisions, the construction subdivision, the generating power stations, the office buildings, the minisplit units and their advantages with respect to the air conditioning window units. [Spanish] Este documento describe los proyectos de ahorro desarrollados en inmuebles y centrales generadoras en el ano 2004 por la Comision Federal de Electricidad (CFE), los proyectos tratados son: inmuebles de oficinas nacionales, inmuebles de divisiones de distribucion, inmuebles de regiones de produccion, inmuebles de la subdireccion de construccion, inmuebles de transmision y transformacion, centrales generadoras, inversiones y ahorros de los proyectos en inmuebles de oficinas nacionales y divisiones de distribucion y subdireccion de construccion. De dichos proyectos se tiene que los proyectos concluidos en el 2004 fueron: Divisiones de Distribucion, Division Golfo Centro, Division de Distribucion Centro Occidente. Los proyectos en desarrollo del 2005: oficinas nacionales, divisiones de distribucion, Subdireccion de Construccion, Centrales Generadoras, Areas de

  10. Experiences on energy saving in Comision Federal Electricidad (CFE) buildings; Experiencias de ahorro de energia en edificios de la Comision Federal de Electricidad (CFE)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Velasco, Jorge E. [Comision Federal de Electricidad (CFE) (Mexico)

    2005-07-01

    This document describes the developed saving projects in buildings and generating power stations in 2004 by the Comision Federal de Electricidad (CFE). The projects considered are: buildings of the oficinas nacionales, Divisions of distribution office buildings, office buildings of production regions, construction deputy manager's office building, buildings of transmission and transformation, generating power stations, investments and savings of the projects in oficinas nacionales, divisions of distribution and construction subdivision buildings. From these projects the ones concluded in the 2004 were: Distribution Divisions, Gulf-Center Division, Center-West Distribution Division. The developing projects of 2005: oficinas nacionales, distribution divisions, Construction Subdivision, Generating Power Stations, Transmission Areas and office buildings. And finally, the projects concluded in the 2005 are the distribution divisions, the construction subdivision, the generating power stations, the office buildings, the minisplit units and their advantages with respect to the air conditioning window units. [Spanish] Este documento describe los proyectos de ahorro desarrollados en inmuebles y centrales generadoras en el ano 2004 por la Comision Federal de Electricidad (CFE), los proyectos tratados son: inmuebles de oficinas nacionales, inmuebles de divisiones de distribucion, inmuebles de regiones de produccion, inmuebles de la subdireccion de construccion, inmuebles de transmision y transformacion, centrales generadoras, inversiones y ahorros de los proyectos en inmuebles de oficinas nacionales y divisiones de distribucion y subdireccion de construccion. De dichos proyectos se tiene que los proyectos concluidos en el 2004 fueron: Divisiones de Distribucion, Division Golfo Centro, Division de Distribucion Centro Occidente. Los proyectos en desarrollo del 2005: oficinas nacionales, divisiones de distribucion, Subdireccion de Construccion, Centrales Generadoras, Areas

  11. Familia: Consumo y ahorro

    OpenAIRE

    Navarro López, Manuel

    2003-01-01

    Es obvio que el contenido de este trabajo deberá moverse entre la sociología de la familia y la del consumo, aunque solo sea como referentes teóricos. Sin embargo, tales vínculos deberán ser solo puntos de apoyo para analizar sin ataduras académicas una visión de los comportamientos económicos que tienen su localización primaria en la familia. Consecuentemente, tendremos que hacer una descripción de esos comportamientos y sus contenidos, su evolución y su diversificación, retomando los motivo...

  12. Familia: Consumo y ahorro

    Directory of Open Access Journals (Sweden)

    Navarro López, Manuel

    2003-01-01

    Full Text Available Es obvio que el contenido de este trabajo deberá moverse entre la sociología de la familia y la del consumo, aunque solo sea como referentes teóricos. Sin embargo, tales vínculos deberán ser solo puntos de apoyo para analizar sin ataduras académicas una visión de los comportamientos económicos que tienen su localización primaria en la familia. Consecuentemente, tendremos que hacer una descripción de esos comportamientos y sus contenidos, su evolución y su diversificación, retomando los motivos más recurrentes al uso, pero con la orientación hacia la familia como institución y como grupo en las sociedades avanzadas actuales…

  13. Pumps in nuclear power plants

    International Nuclear Information System (INIS)

    Kim, J.H.

    1991-01-01

    This paper reports that pumps play an important role in nuclear plant operation. For instance, reactor coolant pumps (RCPs) should provide adequate cooling for reactor core in both normal operation and transient or accident conditions. Pumps such as Low Pressure Safety Injection (LPSI) pump in the Emergency Core Cooling System (ECCS) play a crucial role during an accident, and their reliability is of paramount importance. Some key issues involved with pumps in nuclear plant system include the performance of RCP under two-phase flow conditions, piping vibration due to pump operating in two-phase flows, and reliability of LPSI pumps

  14. Inservice testing of vertical pumps

    International Nuclear Information System (INIS)

    Cornman, R.E. Jr.; Schumann, K.E.

    1994-01-01

    This paper focuses on the problems that may occur with vertical pumps while inservice tests are conducted in accordance with existing American Society of Mechanical Engineers Code, Section XI, standards. The vertical pump types discussed include single stage, multistage, free surface, and canned mixed flow pumps. Primary emphasis is placed on the hydraulic performance of the pump and the internal and external factors to the pump that impact hydraulic performance. In addition, the paper considers the mechanical design features that can affect the mechanical performance of vertical pumps. The conclusion shows how two recommended changes in the Code standards may increase the quality of the pump's operational readiness assessment during its service life

  15. 40 CFR 264.1052 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... fluid at a pressure that is at all times greater than the pump stuffing box pressure, or (ii) Equipped... barrier fluid into a hazardous waste stream with no detectable emissions to the atmosphere. (2) The...

  16. 40 CFR 63.1007 - Pumps in light liquid service standards.

    Science.gov (United States)

    2010-07-01

    ... malfunction) greater than the pump stuffing box pressure; or (B) Equipped with a barrier fluid degassing... system that purges the barrier fluid into a process stream. (iii) The barrier fluid is not in light...

  17. 40 CFR 265.1052 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... pressure that is at all times greater than the pump stuffing box pressure, or (ii) Equipped with a barrier... a hazardous waste stream with no detectable emissions to the atmosphere. (2) The barrier fluid...

  18. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    The polymetallic nodules occur at an average depth of 4500 m. Adequate equipment and techniques are required for the exploration at such depths. Shipboard and various laboratory equipments for the sampling of polymetallic nodules is described...

  19. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  20. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  1. An energy and cost analysis of residential heat pumps in northern climates

    Science.gov (United States)

    Martin, J. K.; Oneal, D. L.

    1980-04-01

    Lack of natural gas and high oil prices, combined with the large energy costs of electric resistance heat have forced renewed attention to the heat pump in colder climates. The diversity in heating energy use and cost effectiveness of forty-one currently retailed heat pumps in three northern cities, Boston, Denver, and Minneapolis, were examined. Heat pump heating energy use and annualized life cycle costs were compared with other forms of space heating equipment in those same cities.

  2. SIMULATION MODELS OF RESISTANCE TO CONCRETE MOVEMENT IN THE CONCRETE CONVEYING PIPE OF THE AUTOCONCRETE PUMP

    OpenAIRE

    Anofriev, P. G.

    2015-01-01

    Purpose. In modern construction the placing of concrete is often performed using distribution equipment of concrete pumps. Increase of productivity and quality of this construction work requires improvement of both concrete pumps and their tooling. The concrete pumps tooling consists of standardized concrete conveying pipes and connector bends radius of up to 2 m. A promising direction of tooling improvement is the reduce of resistance to movement of the concrete in the concrete conveying pip...

  3. 46 CFR 34.10-5 - Fire pumps-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps-T/ALL. 34.10-5 Section 34.10-5 Shipping COAST... § 34.10-5 Fire pumps—T/ALL. (a) Tankships shall be equipped with independently driven fire pumps in accordance with table 34.10-5(a). Table 34.10-5(a)—Fire Pumps Size vessel, L.O.A. (feet) Over— Not over...

  4. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  5. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  6. Comparison of infusion pumps calibration methods

    Science.gov (United States)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  7. Open-Source Syringe Pump Library

    Science.gov (United States)

    Wijnen, Bas; Hunt, Emily J.; Anzalone, Gerald C.; Pearce, Joshua M.

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications. PMID:25229451

  8. Ultrasonic Examination of Jet Pump Diffuser Assemblies

    International Nuclear Information System (INIS)

    Hacker, M.; Levesque, M.; Whitman, G.

    1998-01-01

    In October 1997 the Boiling Water REactor Vessel and Internals Project (BWRVIP) issued the BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines (BWRVIP-41). This document identified several welds on the jet pump diffuser assembly that are susceptible to Intergranular Stress Corrosion Cracking (IGSCC) or fatigue, and whose failure could result in jet pump disassembly. Based on the potential for failures, the document recommends inspection of 50% of the high priority welds at the next refueling outage for each BWR, with 100% expansion if flaws are identified. Because each diffuser assembly contains as many as six high priority welds, and access to these welds from the annulus is very restricted, implementing these recommendations can have a significant impact on outage critical path. In an effort to minimize the impact of implementing these recommendations, Framatome Technologies, Inc (FTI) developed a method to perform ultrasonic examinations of the jet pump diffuser assembly welds utilizing remotely operated equipment from the inner diameter (ID) of the diffuser assembly. This paper will discuss the tooling, ultrasonic methods, and delivery techniques used to perform the examinations, as well as the results obtained from a spring 1998 deployment of the system at a U.S. Nuclear Generating Plant. (Author)

  9. On-line PWR RHR pump performance testing following motor and impeller replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiMarzo, J.T.

    1996-12-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump`s `B` impeller. The spare was installed into the `B` train. The motor had never been run in the system before. A pump performance test was developed to verify it`s operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the `B` Train showed performance well in excess of the minimum required. The motor that was originally in the `B` train was similarly overhauled and equipped with `A` pump`s original impeller, re-installed in the `A` train, and tested. Analysis of the `A` train results indicate that the RHR pump`s performance was also well in excess of the vendors requirements.

  10. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  11. 10 CFR 431.92 - Definitions concerning commercial air conditioners and heat pumps.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Definitions concerning commercial air conditioners and... PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps § 431.92 Definitions concerning commercial air conditioners and heat pumps. The following definitions apply...

  12. 40 CFR 63.163 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... handling polymerizing monomers; (B) 2,000 parts per million or greater for pumps in food/medical service... current monitoring period. (e) Each pump equipped with a dual mechanical seal system that includes a barrier fluid system is exempt from the requirements of paragraphs (a) through (d) of this section...

  13. Pumping Optimization Model for Pump and Treat Systems - 15091

    Energy Technology Data Exchange (ETDEWEB)

    Baker, S.; Ivarson, Kristine A.; Karanovic, M.; Miller, Charles W.; Tonkin, M.

    2015-01-15

    Pump and Treat systems are being utilized to remediate contaminated groundwater in the Hanford 100 Areas adjacent to the Columbia River in Eastern Washington. Design of the systems was supported by a three-dimensional (3D) fate and transport model. This model provided sophisticated simulation capabilities but requires many hours to calculate results for each simulation considered. Many simulations are required to optimize system performance, so a two-dimensional (2D) model was created to reduce run time. The 2D model was developed as a equivalent-property version of the 3D model that derives boundary conditions and aquifer properties from the 3D model. It produces predictions that are very close to the 3D model predictions, allowing it to be used for comparative remedy analyses. Any potential system modifications identified by using the 2D version are verified for use by running the 3D model to confirm performance. The 2D model was incorporated into a comprehensive analysis system (the Pumping Optimization Model, POM) to simplify analysis of multiple simulations. It allows rapid turnaround by utilizing a graphical user interface that: 1 allows operators to create hypothetical scenarios for system operation, 2 feeds the input to the 2D fate and transport model, and 3 displays the scenario results to evaluate performance improvement. All of the above is accomplished within the user interface. Complex analyses can be completed within a few hours and multiple simulations can be compared side-by-side. The POM utilizes standard office computing equipment and established groundwater modeling software.

  14. 40 CFR 270.310 - What equipment information must I keep at my facility?

    Science.gov (United States)

    2010-07-01

    ...) Method of compliance with the standard (e.g., monthly leak detection and repair, or equipped with dual... (e.g., a pump or a pipeline valve). (4) Percent by weight of total organics in the hazardous waste...

  15. Miscellaneous component design for Tank 241SY101 pump removal

    International Nuclear Information System (INIS)

    Huang, F.H.

    1995-01-01

    A mixer pump has been used to mitigate the hydrogen build-up in tank 241SY101 (SY101), located in the 200 West Area of the Hanford Site. New equipment is being prepared for the removal, transport, storage, and disposal of the test pump. The disposal equipment for the test pump now in tank SY101 includes a shipping container, a strong back, a lifting beam, a test weight, container support stands, a modified mock-up pump, a flexible receiver blast shield, a lifting yoke, and a yoke brace. The structural evaluations of container and strong back are detailed in another supporting document (WHC 1994a), the engineering analyses of flexible receiver blast shield/lifting yoke and yoke brace are given in other supporting documents (WHC 1994b, WHC 1994c), respectively. Engineering tasks that were contracted to Advanced Engineering Consultants (AEC) include the design and analysis of the following. Two spreader-beam lifting devices. a Container test weight. Container support saddles. Mock-up pump modification. This report documents the work description, design basis, assumptions, and design calculations provided by AEC for the above components. All AEC documents appear in Appendix A. Additional work conducted by Westinghouse Hanford Company (WHC) on the modified container test weight, modification to the mock-up pump, the removable support for the transport assembly, and saddle modification for air pallets also are included in this document

  16. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  17. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  18. Combined system of solar heating and cooling using heat pump

    International Nuclear Information System (INIS)

    Zakhidov, R.A.; Anarbaev, A.I.

    2014-01-01

    The heating and cooling systems of apartment buildings based on combined solar heat-pump equipment has been considered and the procedure of calculating its parameters has been worked out. A technical-economic analysis has been performed and compared with the boiler-setting version. (author)

  19. Reversible pumped hydro - benefits and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Torbjoern K.; Walseth, Eve C.

    2010-07-01

    Full text: The Norwegian hydro power system is dominated with high head turbines, Pelton and Francis with high capacity in the reservoirs. Originally they were built for secure energy supply. In the system there are also reversible pump turbine (RPT) plants where in times with spare energy, made it possible to pump water from the lower reservoir to the higher. Again the idea was to secure energy supply, which meant pumping in early autumn to fill the reservoirs for winter. In the recent years, a more active use of the RPT plants has been actualized. The free market made price difference between night and day interesting, hence a more frequent pumping was desirable. In the coming years, new-renewable energy sources will utterly enhance a more active use of the RPT plants. More active use of the RPT plants means more frequent starts and stops, both in pumping and in turbine mode. There are a lot of challenges in adopting a new strategy for operating the machinery. More effective start equipment is required. The machinery will be exposed to more frequent dynamic loads; the turbines will be run at part- and full load. The existing RPT plants are connected to huge reservoirs. That means the RPTs are not only for short sighted power regulations, as many RPT-plants in Europe, but are also capable for a substantial energy production. In Norway, the nature is very suitable for RPT plants, both in connection with existing power plants, were reservoirs and conduits are already established, and standing alone with a minimum of energy production. RPTs are, as a design, a compromise between effective generating and stable as well as effective pumping. Stable pumping often results in very steep flow-speed characteristics when operating as a turbine. When dealing with hydraulic transients these characteristics cause a higher change in flow and torque leading to instability during start-up and possible off-design operation point. The instability slows down the synchronization

  20. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  1. Wet motor geroter fuel pump

    Energy Technology Data Exchange (ETDEWEB)

    Wiernicki, M.V.

    1987-05-05

    This patent describes a wet motor gerotor fuel pump for pumping fuel from a fuel source to an internal combustion which consists of: gerotor pump means comprising an inner pump gear, an outer pump gear, and second tang means located on one of the inner and outer pump gears. The second tang means further extends in a second radial direction radially offset from the first radial direction and forms a driving connection with the first tang means such that the fuel pump pumps fuel from the fuel source into the narrow conduit inlet chamber, through the gerotor pump means past the electric motor means into the outlet housing means substantially along the flow axis to the internal combustion engine.

  2. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  3. Fusion reactor pumped laser

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1988-01-01

    A nuclear pumped laser is described comprising: a toroidal fusion reactor, the reactor generating energetic neutrons; an annular gas cell disposed around the outer periphery of the reactor, the cell including an annular reflecting mirror disposed at the bottom of the cell and an annular output window disposed at the top of the cell; a gas lasing medium disposed within the annular cell for generating output laser radiation; neutron reflector material means disposed around the annular cell for reflecting neutrons incident thereon back into the gas cell; neutron moderator material means disposed between the reactor and the gas cell and between the gas cell and the neutron reflector material for moderating the energy of energetic neutrons from the reactor; converting means for converting energy from the moderated neutrons to energy pumping means for pumping the gas lasing medium; and beam compactor means for receiving output laser radiation from the annular output window and generating a single output laser beam therefrom

  4. Method for keeping equipment and pipeline of nuclear power plant

    International Nuclear Information System (INIS)

    Okubo, Osamu.

    1990-01-01

    The present invention intends to suppress corrosion of equipments and pipelines in condensate, feedwater and feedwater heater drain systems during operation of a nuclear power plant. That is, condensate, feedwater and drain remained in equipments and pipelines just after the stopping of operation are passed through pipelines comprising only conduits, or they are introduced to a condensator passing through the pipelines and condensate pipes. Further, the remaining droplets on the inner surfaces are evaporated by the remaining heat of the equipments and the pipelines themselves. Then, the equipments and pipelines are isolated from other regions and kept. In view of the above, since condensate, feedwater and water feeder drains are introduced directly to the condensator passing through the conduits in which other equipments such as tanks and pumps are not present and are isolated and kept, corrosion of the equipments and the pipelines is suppressed and radioactive contamination is suppressed from prevailing by way of cruds. (I.S.)

  5. The methodology for the evaluation of the energy saving by the daylight saving time in Mexico; Metodologia para la evaluacion del ahorro de energia debido al cambio de horario durante la epoca del verano

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    A description is made of the methodology for the evaluation of energy saving by the daylight saving time in Mexico. A mathematical model was developed that would allow the quantitative evaluation of the energy saving by the daylight saving time, through measurements of the consumption of different users from the domestic commercial and industrial sector, considering the various variables that impact the consumption [Espanol] Se describe la metodologia para la evalucion del ahorro de energia por el cambio de horario de verano en Mexico. Se desarrollo un modelo matematico que permitiera evaluar cuantitativamente el ahorro de energia debido al cambio de horario durante la epoca de verano, atraves de mediciones de consumos de los diferentes usuarios de los sectores domestico, comercial e industrial, considerando las diversas variables que impactan en el consumo

  6. The methodology for the evaluation of the energy saving by the daylight saving time in Mexico; Metodologia para la evaluacion del ahorro de energia debido al cambio de horario durante la epoca del verano

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    A description is made of the methodology for the evaluation of energy saving by the daylight saving time in Mexico. A mathematical model was developed that would allow the quantitative evaluation of the energy saving by the daylight saving time, through measurements of the consumption of different users from the domestic commercial and industrial sector, considering the various variables that impact the consumption [Espanol] Se describe la metodologia para la evalucion del ahorro de energia por el cambio de horario de verano en Mexico. Se desarrollo un modelo matematico que permitiera evaluar cuantitativamente el ahorro de energia debido al cambio de horario durante la epoca de verano, atraves de mediciones de consumos de los diferentes usuarios de los sectores domestico, comercial e industrial, considerando las diversas variables que impactan en el consumo

  7. 241-AZ-101 pump removal trough analysis

    International Nuclear Information System (INIS)

    Coverdell, B.L.

    1995-01-01

    As part of the current Hanford mission of environmental cleanup, various long length equipment must be removed from highly radioactive waste tanks. The removal of equipment will utilize portions of the Equipment Removal System for Project W320 (ERS-W320), specifically the 50 ton hydraulic trailer system. Because the ERS-W320 system was designed to accommodate much heavier equipment it is adequate to support the dead weight of the trough, carriage and related equipment for 241AZ101 pump removal project. However, the ERS-W320 components when combined with the trough and its' related components must also be analyzed for overturning due to wind loads. Two troughs were designed, one for the 20 in. diameter carriage and one for the 36 in. diameter carriage. A proposed 52 in. trough was not designed and, therefore is not included in this document. In order to fit in the ERS-W320 strongback the troughs were design with the same widths. Structurally, the only difference between the two troughs is that more material was removed from the stiffener plates on the 36 in trough. The reduction in stiffener plate material reduces the allowable load. Therefore, only the 36 in. trough was analyzed

  8. In situ performance curves measurements of large pumps

    International Nuclear Information System (INIS)

    Anton, A

    2010-01-01

    The complex energetic system on the river Lotru in Romania comprises of a series of lakes and pumping stations and a major hydroelectric power plant: Lotru-Ciunget. All the efforts have been oriented towards the maintenance of the Pelton turbines and very little attention has been directed to the pumps. In the system, there are three large pumping stations and only in the last 5 years, the pump performances have become a concern. The performances where determined using portable ultrasonic flow meters, a Yates meter, precision manometers and appropriate electrical equipment for power measurement (Power Analiser - NORMA D4000 LEM). The measurements are not supposed to interfere with the normal operation so only a limited number of tests could be performed. Based on those tests, portions of the test curves have been measured and represented in specific diagrams.

  9. In situ performance curves measurements of large pumps

    Science.gov (United States)

    Anton, A.

    2010-08-01

    The complex energetic system on the river Lotru in Romania comprises of a series of lakes and pumping stations and a major hydroelectric power plant: Lotru-Ciunget. All the efforts have been oriented towards the maintenance of the Pelton turbines and very little attention has been directed to the pumps. In the system, there are three large pumping stations and only in the last 5 years, the pump performances have become a concern. The performances where determined using portable ultrasonic flow meters, a Yates meter, precision manometers and appropriate electrical equipment for power measurement (Power Analiser - NORMA D4000 LEM). The measurements are not supposed to interfere with the normal operation so only a limited number of tests could be performed. Based on those tests, portions of the test curves have been measured and represented in specific diagrams.

  10. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  11. Acoustical heat pumping engine

    Science.gov (United States)

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1983-08-16

    The disclosure is directed to an acoustical heat pumping engine without moving seals. A tubular housing holds a compressible fluid capable of supporting an acoustical standing wave. An acoustical driver is disposed at one end of the housing and the other end is capped. A second thermodynamic medium is disposed in the housing near to but spaced from the capped end. Heat is pumped along the second thermodynamic medium toward the capped end as a consequence both of the pressure oscillation due to the driver and imperfect thermal contact between the fluid and the second thermodynamic medium. 2 figs.

  12. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  13. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  14. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  15. Carbon sheet pumping

    International Nuclear Information System (INIS)

    Ohyabu, N.; Sagara, A.; Kawamura, T.; Motojima, O.; Ono, T.

    1993-07-01

    A new hydrogen pumping scheme has been proposed which controls recycling of the particles for significant improvement of the energy confinement in toroidal magnetic fusion devices. In this scheme, a part of the vacuum vessel surface near the divertor is covered with carbon sheets of a large surface area. Before discharge initiation, the sheets are baked up to 700 ∼ 1000degC to remove the previously trapped hydrogen atoms. After being cooled down to below ∼ 200degC, the unsaturated carbon sheets trap high energy charge exchange hydrogen atoms effectively during a discharge and overall pumping efficiency can be as high as ∼ 50 %. (author)

  16. Vacuum pumping concepts for ETF

    International Nuclear Information System (INIS)

    Homeyer, W.G.

    1980-09-01

    The Engineering Test Facility (ETF) poses unique vacuum pumping requirements due to its large size and long burn characteristics. These requirements include torus vacuum pumping initially and between burns and pumping of neutralized gas from divertor collector chambers. It was found that the requirements could be met by compound cryopumps in which molecular sieve 5A is used as the cryosorbent. The pumps, ducts, and vacuum valves required are large but fit with other ETF components and do not require major advances in vacuum pumping technology. Several additional design, analytical, and experimental studies were identified as needed to optimize designs and provide better design definition for the ETF vacuum pumping systems

  17. 14 CFR 135.167 - Emergency equipment: Extended overwater operations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Emergency equipment: Extended overwater operations. 135.167 Section 135.167 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) One CO2 bottle for emergency inflation; (x) One inflation pump; (xi) Two oars; (xii) One 75-foot...

  18. Time Deployment Study for Annulus Pumping

    International Nuclear Information System (INIS)

    REBERGER, D.W.

    2000-01-01

    Radioactive wastes from processing irradiated uranium fuels have been stored as alkaline slurries in underground tanks at the Hanford Site. Single-shell tanks (SST) and double-shell tanks (DST) of various sizes were used for waste storage. Of the total 177 tanks, there are 28 DSTs. DSTs are located in AN, AP, AW, AY, AZ, and SY tank farms in the 200 East (200E) and 200-West (200W) Areas. The storage capacities of the DSTs vary from 980,000 to 1,140,000 gal. DSTs are designed and constructed as an integral steel structure, i.e., an inner shell within an outer shell, so that any leak from the inner shell is confined within the annulus without impacting the environment. The inner shell provides primary containment for the wastes and the outer shell provides secondary containment in the form of an annulus. The annulus of a DST is equipped with a pump pit, leak detection probes, and other accessories. The existing annulus pumps in the DSTs need to be revamped with a new system to reduce operating costs and reduce the time to deploy a pumping system. The new pumping system will minimize the likelihood of a release of waste into the environment; improve capability of waste removal to the maximum extent possible to comply with Washington Administrative Code (WAC) 173-303-640 and Code of Federal Regulations (CFR) 40 CFR 265.193. This study addresses the time required to deploy an annulus pumping system designed to fit any DST after detection of a leak in the inner shell of the DST

  19. Active magnetic bearings: As applied to centrifugal pumps

    Science.gov (United States)

    Nelik, Lev; Cooper, Paul; Jones, Graham; Galecki, Dennis; Pinckney, Frank; Kirk, Gordon

    1992-05-01

    Application of magnetic bearings to boiler feed pumps presents various attractive features, such as longer bearing life, lower maintenance costs, and improved operability through control of the rotordynamics. Magnetic bearings were fitted to an eight-stage, 600 hp boiler feed pump, which generates 2600 ft of heat at 680 gpm and 3560 rpm. In addition to the varied and severe operating environment in steady state operation of this pump in a power plant, it is also subjected to transient loads during frequent starts and stops. These loads can now be measured by the in-built instrumentation of the magnetic bearings. Following site installation, a follow-up bearing tune-up was performed, and pump transient response testing was conducted. The bearing response was completely satisfactory, ensuring trouble-free pump operation even in the range of reduced load. The experience gained so far through design and testing proves feasibility of magnetic bearings for boiler feed pumps, which sets the stage for application of even higher energy centrifugal pumps equipped with magnetic bearings.

  20. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  1. 46 CFR 32.50-1 - Cargo pumps for tank vessels constructed on or after November 10, 1936-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo pumps for tank vessels constructed on or after... TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Pumps, Piping, and Hose for Cargo Handling § 32.50-1 Cargo pumps for tank vessels constructed on or after November 10, 1936—TB/ALL. On all...

  2. 46 CFR 32.50-25 - Cargo pumps and piping on tank vessels constructed prior to November 10, 1936-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo pumps and piping on tank vessels constructed prior... SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Pumps, Piping, and Hose for Cargo Handling § 32.50-25 Cargo pumps and piping on tank vessels constructed prior to November 10, 1936—TB/ALL...

  3. Study of Hydrogen Pumping through Condensed Argon in Cryogenic pump

    International Nuclear Information System (INIS)

    Jadeja, K A; Bhatt, S B

    2012-01-01

    In ultra high vacuum (UHV) range, hydrogen is a dominant residual gas in vacuum chamber. Hydrogen, being light gas, pumping of hydrogen in this vacuum range is limited with widely used UHV pumps, viz. turbo molecular pump and cryogenic pump. Pre condensed argon layers in cryogenic pump create porous structure on the surface of the pump, which traps hydrogen gas at a temperature less than 20° K. Additional argon gas injection in the cryogenic pump, at lowest temperature, generates multiple layers of condensed argon as a porous frost with 10 to 100 A° diameters pores, which increase the pumping capacity of hydrogen gas. This pumping mechanism of hydrogen is more effective, to pump more hydrogen gas in UHV range applicable in accelerator, space simulation etc. and where hydrogen is used as fuel gas like tokamak. For this experiment, the cryogenic pump with a closed loop refrigerator using helium gas is used to produce the minimum cryogenic temperature as ∼ 14° K. In this paper, effect of cryosorption of hydrogen is presented with different levels of argon gas and hydrogen gas in cryogenic pump chamber.

  4. Solar pumped laser

    Science.gov (United States)

    Lee, J. H.; Hohl, F.; Weaver, W. R. (Inventor)

    1984-01-01

    A solar pumped laser is described in which the lasant is a gas that will photodissociate and lase when subjected to sunrays. Sunrays are collected and directed onto the gas lasant to cause it to lase. Applications to laser propulsion and laser power transmission are discussed.

  5. Cryogenic vacuum pump design

    International Nuclear Information System (INIS)

    Bartlett, A.J.; Lessard, P.A.

    1984-01-01

    This paper is a review of the problems and tradeoffs involved in cryogenic vacuum pump analysis, design and manufacture. Particular attention is paid to the several issues unique to cryopumps, e.g., radiation loading, adsorption of noncondensible gases, and regeneration. A general algorithm for cryopump design is also proposed. 12 references

  6. Pump monitoring and analysis

    International Nuclear Information System (INIS)

    Guy, K.R.

    1992-01-01

    The paper describes how to set up a periodic vibration monitoring program implemented with electronic data loggers. Acquired data will be analyzed and evaluated to determine pump condition. Periodic measuring frequency, reporting procedures, and conditions of mechanical components are discussed in detail based on the actual case study

  7. Magnetic-flux pump

    Science.gov (United States)

    Hildebrandt, A. F.; Elleman, D. D.; Whitmore, F. C. (Inventor)

    1966-01-01

    A magnetic flux pump is described for increasing the intensity of a magnetic field by transferring flux from one location to the magnetic field. The device includes a pair of communicating cavities formed in a block of superconducting material, and a piston for displacing the trapped magnetic flux into the secondary cavity producing a field having an intense flux density.

  8. Putzmeister pumps for Tchernobyl

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Self-propelling concrete pumps are briefly described in this article, they comprise a 52-meter boom, a radiation protection, remote control, videocameras. Several units were ordered by the Soviet Union. The truck cabin is protected against radiation by a 10 millimeter thick shield in lead. 3 photographs [fr

  9. Scroll vacuum pump

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Etsuo; Suganami, Takuya; Nishida, Mitsuhiro; Kitora, Yoshihisa; Yamamoto, Sakuei; Fujii, Kosaburo

    1988-02-25

    An effort is made to apply a scroll machine to development of a vacuum pump. In view of mechanical simplification and load patterns, the vacuum pump uses a rotating mechanism to produce paired vortices rotating around each center. Chip seal and atmospheric pressure are utilized for axial gap sealing while a spring and atmospheric pressure for the radial gap sealing. In both gaps, the sealing direction is stationary relative to the environment during rotation, making it much easier to achieve effective sealing as compared to oscillating pumps. Since the compression ratio is high in vacuum pumps, a zero top clearance form is adopted for the central portion of vortices and an gas release valve is installed in the rotating axis. A compact Oldham coupling with a small inertia force is installed behind the vortices to maintain the required phase relations between the vortices. These improvements result in a vacuum of 1 Pa for dry operation and 10/sup -2/ Pa for oil flooded operation of a single-stage scroll machine at 1800 rpm. (5 figs, 1 tab, 4 refs)

  10. Centrifugal blood pump 603

    Indian Academy of Sciences (India)

    Centrifugal blood pump 603 pressure obtained for real blood, as shown in figure 6, is a little higher than that for glycerin aqua Solution with the same viscosity as blood. This may indicate the effect of slight non-. Newtonian turbulent flow. The radial whirl motion of the impeller was observed by dual laser position sensors.

  11. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  12. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  13. Impulse pumping modelling and simulation

    International Nuclear Information System (INIS)

    Pierre, B; Gudmundsson, J S

    2010-01-01

    Impulse pumping is a new pumping method based on propagation of pressure waves. Of particular interest is the application of impulse pumping to artificial lift situations, where fluid is transported from wellbore to wellhead using pressure waves generated at wellhead. The motor driven element of an impulse pumping apparatus is therefore located at wellhead and can be separated from the flowline. Thus operation and maintenance of an impulse pump are facilitated. The paper describes the different elements of an impulse pumping apparatus, reviews the physical principles and details the modelling of the novel pumping method. Results from numerical simulations of propagation of pressure waves in water-filled pipelines are then presented for illustrating impulse pumping physical principles, and validating the described modelling with experimental data.

  14. Sludge pumping in water treatment

    International Nuclear Information System (INIS)

    Solar Manuel, M. A.

    2010-01-01

    In water treatment processes is frequent to separate residual solids, with sludge shape, and minimize its volume in a later management. the technologies to applicate include pumping across pipelines, even to long distance. In wastewater treatment plants (WWTP), the management of these sludges is very important because their characteristics affect load losses calculation. Pumping sludge can modify its behavior and pumping frequency can concern treatment process. This paper explains advantages and disadvantages of different pumps to realize transportation sludge operations. (Author) 11 refs.

  15. Domestic manufacturing and reliability improvement of reactor water recirculation equipment

    International Nuclear Information System (INIS)

    Kobayashi, Hidekazu; Oi, Masao; Shida, Toichi; Yokomori, Takashi

    1982-01-01

    The reactor coolant recirculation system is one of the important systems to control the reactor output in BWR nuclear power plants. Its components require high reliability and maintainability as well as controllability. For many Japanese nuclear power plants, recirculation pumps, fluid couplings and others have been imported so far. Hitachi Ltd. has established a domestic manufacturing organization through the development and test of these equipment. The fundamental design conditions for these equipment are the improvement of the rate of utilization of plant facility, the capability to follow load, and output power stability. In this paper, the specifications, the investigation of moment of inertia and the design features of recirculation pumps, driving motors and variable frequency power supply systems are described. The paper also reports on the combination test implemented to evaluate the recirculation system. The combination test includes the test using water rheostat for the power source facility and the loading test for a recirculation pump. The application of those system equipment to an actual plant was analyzed and evaluated on a basis of the test data obtained. The result showed that the equipment can achieve the rate of change of reactor power of 30%/min. Those equipment have been employed for No. 2 reactor plant of the Fukushima No. 2 Nuclear Power Station, the Tokyo Electric Power Co., Inc. (Wakatsuki, Y.)

  16. Vivitron dead section pumping tests

    International Nuclear Information System (INIS)

    Heugel, J.; Bayet, J.P.; Brandt, C.; Delhomme, C.; Krieg, C.; Kustner, F.; Meiss, R.; Riehl, R.; Roth, C.; Schlewer, B.; Six, P.; Weber, A.

    1990-10-01

    Pumping tests have been conducted on a simulated accelerator dead section. The behavior of different pump types are compared and analyzed. Vacuum conditions to be expected in the Vivitron are reached and several parameters are verified. Selection of a pump for the Vivitron dead section is confirmed

  17. Heat pumps are a dream

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    The fact that heat pumps do not achieve what their manufacturers promise in costs efficiency has been realized by the market. In 1981 the sales of heat pumps decreased by 50% of the 1980 market. Public utilities give the reason as economic, since fuel oil is too cheap. The author refutes this argument and presents arguments against heat pumps.

  18. Evaluación del punto de conmutación unicast- multicast para ahorro de potencia de transmisión en redes MBMS

    Directory of Open Access Journals (Sweden)

    Raúl Tamayo Fernández

    2014-01-01

    Full Text Available La oferta de aplicaciones y servicios multimedia para terminales móviles se hace principalmente a través de las redes celulares de tercera y cuarta generación (3G/4G existentes. El envío de los datos en este tipo de redes se realiza en modo unicast, es decir, a cada usuario se le dedican recursos de radio (ancho de banda y potencia de transmisión durante toda la sesión. Esto presenta algunos inconvenientes, tales como agotamiento rápido del ancho de banda del operador móvil, alto consumo de potencia de transmisión, incremento de la interferencia, y costos altos del servicio. Los operadores móviles requieren de nuevas tecnologías que optimicen el uso de sus recursos de radio y así lograr un mayor índice de penetración de los servicios. De ahí la necesidad de cambiar de paradigma hacia un modo de transmisión en multicast o broadcast, en el que una misma señal pueda recibirse por varios usuarios simultáneamente, de tal forma que los recursos de radio se puedan compartir. Para ello, la solución técnica sobre redes celulares LTE (Long Term Evolution se dio en la especificación 3GPP Release 6, llamada Servicio Multimedia por Broadcast/Multicast (MBMS, Multimedia Broadcast Multicast Service. La especificación de MBMS permite que una transmisión cambie de modo unicast a modo multicast a partir de un “punto de conmutación”, que determina el momento de hacer el cambio para obtener un ahorro tanto en ancho de banda como en potencia de transmisión. Este artículo presenta una evaluación para determinar los puntos de conmutación de modo de transmisión óptimos en el estándar MBMS para diferentes ambientes de propagación inalámbrica. Además, dado que MBMS se puede utilizar en topologías de Red de Frecuencia Única (SFN, Single Frequency Networks, que tienen la propiedad de “ganancia de red”, también se determina el ahorro de potencia de transmisión adicional que se obtiene en esta configuración.

  19. Análisis de costes y ahorros potenciales relacionados con la utilización de pruebas preoperatorias en los hospitales de Canarias

    Directory of Open Access Journals (Sweden)

    López-Bastida J.

    2003-01-01

    Full Text Available Objetivos: Estimar el ahorro potencial que podría tener lugar en el Servicio Canario de Salud (SCS, a partir de una utilización apropiada científica de las pruebas preoperatorias, haciendo uso de la información obtenida de los 5 hospitales universitarios de la red pública. Métodos: Un total de 55 anestesiólogos (60% del SCS cumplimentaron un cuestionario. En éste se prestó especial atención a las pruebas preoperatorias más frecuentemente utilizadas, como la radiografía de tórax, el electrocardiograma, las pruebas de laboratorio y la espirometría. Los costes unitarios medios para las diferentes pruebas preoperatorias se obtuvieron de 2 hospitales participantes en el estudio. Para calcular los ahorros potenciales derivados del uso apropiado de las pruebas preoperatorias se han considerado varios escenarios caracterizados por diferentes hipótesis o grados de cumplimiento de un protocolo basado en el conocimiento científico, considerado como parámetro de referencia. Resultados: En el caso ideal de que se cumpliera el protocolo científico recomendado en el 100% de los 16.179 pacientes considerados ASA I y II, la repercusión económica sería notable, pues supondría una liberación de recursos sensible que podría ser utilizada para otros programas de salud. Estas cifras podrían alcanzar aproximadamente los 1,02 millones de euros, sin considerar el coste de la estancia preoperatoria. Esta cifra podría incrementarse hasta, aproximadamente, los 2,13 millones de euros si incluimos un día de estancia preoperatoria, y hasta los 3,24 millones de euros incluyendo 2 días de estancia preoperatoria. Conclusiones: La revisión reciente de la literatura científica y los resultados proporcionados por el cuestionario aplicado en el SCS indican que las pruebas preoperatorias alcanzan los mayores beneficios para los pacientes y para la sociedad si se guían por el conocimiento científico. Es posible, además, liberar recursos a partir de una

  20. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  1. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  2. Pumping characteristics of roots blower pumps for light element gases

    International Nuclear Information System (INIS)

    Hiroki, Seiji; Abe, Tetsuya; Tanzawa, Sadamitsu; Nakamura, Jun-ichi; Ohbayashi, Tetsuro

    2002-07-01

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H 2 , D 2 and He) and for N 2 , in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m 3 /s), two EH250s (ibid. 250 m 3 /s) and a backing pump (ibid. 100 m 3 /s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D 2 and N 2 were 1200 and 1300 m 3 /h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  3. Implementation of an RHR/LPSI pump coupling retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; Koch, R.P.; Orewyler, R.; Tipton, J.W.

    1994-01-01

    Nuclear plant operating experience has shown the RHR and LPSI services to be very demanding on pumps. The systems handle borated water at high temperatures and pressures with frequent step changes in both temperature and pressure. Additionally, the industry trend towards reduced flow rates during plant mid-loop (reduced inventory) conditions has resulted in extended pump operation at flow rates significantly below the pump best efficiency point flow. Operation at these low flow fates is known to cause high thrust loads and large shaft deflections. The combination of these and other factors have resulted in short mechanical seal life and short motor bearing life, thus requiring frequent pump and motor maintenance. For many nuclear plants, including Southern California Edison's (SCE) San Onofre Units 2 and 3, these pumps have represented a major operations and maintenance (O ampersand M) expenditure and a significant source of radiation exposure to plant personnel. SCE management determined that a pump upgrade was justified to reduce the O ampersand M costs and to improve plant availability. SCE decided to proceed with a pump retrofit program to improve the pump maintainability, reliability and availability. Installation was completed for four LPSI pumps at San Onofre Units 2 and 3 during the Cycle 7 refueling outages in 1993. A key to the program's success was the removal of many traditional supplier and customer barriers and revision of supplier and customer roles to create a unified team. This paper traces the RHR/LPSI retrofit program for San Onofre from problem identification to project implementation. The team approach used for this program and the lessons learned may be useful to other utilities and vendors when evaluating or implementing system and equipment upgrades

  4. Scenarios simulation for the conservation and efficient use of energy, using passive control measures; Simulacion de escenarios de ahorro y uso eficiente de energia, utilizando medidas de control pasivo

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, G.; Heard, Ch.; Sanchez Viveros, A. [Instituto de Investigaciones Electricas,Cuernavaca (Mexico)

    1997-12-31

    Every one involved with the conservation and efficient use of electric energy, has listened in reiterative occasions to the causes that changed the conventional mentality at the beginning of the seventies. Nevertheless, there are many persons that still ignore that by using the energy rationally, their costs are significantly reduced, their comfort is enhanced and the environmental problems are minimized. Specifically, in the domestic sector, from the figures reported by the Comision Federal de Electricidad (CFE) in 1996, the electric energy sold was 28,410 Gwh, that is, 23.4% of the total consumption (121,579 Gwh). Table 1 presents the average by tariff in the national domestic sector, which shows that 20% of the electricity consumed was required for environmental conditioning (air conditioning, evaporative coolers and electric fans). The above figures quantitatively show that there is a strong impact in the consumption of electric energy due to weather conditions. For this reason, currently the Comision Nacional de Ahorro de Energia (CONAE) and the Fideicomiso para el Ahorro de Energia (FIDE) are promoting standards and projects to propitiate the rationalization in the use of energy, besides of achieving the improvement of thermal comfort conditions. One more case would be the Fideicomiso para el Aislamiento Termico de la Vivienda en Mexicali (FIPATERM), which promotes the financing of saving measures and efficient energy use in cities with extreme climate. This paper describes the strategy that was followed by the Instituto de Investigaciones Electricas (IIE), for the development of the human and material infrastructure, that has allowed the sustainment of several projects in the saving and efficient use of energy in CFE, CONAE, FIDE, FIPATERM and the Lawrence Berkeley National Laboratory (LBNL), concretely in relationship with the thermal analysis of dwellings. [Espanol] Todos aquellos relacionados con el ahorro y el uso eficiente de la energia electrica, han

  5. Scenarios simulation for the conservation and efficient use of energy, using passive control measures; Simulacion de escenarios de ahorro y uso eficiente de energia, utilizando medidas de control pasivo

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, G; Heard, Ch; Sanchez Viveros, A [Instituto de Investigaciones Electricas,Cuernavaca (Mexico)

    1998-12-31

    Every one involved with the conservation and efficient use of electric energy, has listened in reiterative occasions to the causes that changed the conventional mentality at the beginning of the seventies. Nevertheless, there are many persons that still ignore that by using the energy rationally, their costs are significantly reduced, their comfort is enhanced and the environmental problems are minimized. Specifically, in the domestic sector, from the figures reported by the Comision Federal de Electricidad (CFE) in 1996, the electric energy sold was 28,410 Gwh, that is, 23.4% of the total consumption (121,579 Gwh). Table 1 presents the average by tariff in the national domestic sector, which shows that 20% of the electricity consumed was required for environmental conditioning (air conditioning, evaporative coolers and electric fans). The above figures quantitatively show that there is a strong impact in the consumption of electric energy due to weather conditions. For this reason, currently the Comision Nacional de Ahorro de Energia (CONAE) and the Fideicomiso para el Ahorro de Energia (FIDE) are promoting standards and projects to propitiate the rationalization in the use of energy, besides of achieving the improvement of thermal comfort conditions. One more case would be the Fideicomiso para el Aislamiento Termico de la Vivienda en Mexicali (FIPATERM), which promotes the financing of saving measures and efficient energy use in cities with extreme climate. This paper describes the strategy that was followed by the Instituto de Investigaciones Electricas (IIE), for the development of the human and material infrastructure, that has allowed the sustainment of several projects in the saving and efficient use of energy in CFE, CONAE, FIDE, FIPATERM and the Lawrence Berkeley National Laboratory (LBNL), concretely in relationship with the thermal analysis of dwellings. [Espanol] Todos aquellos relacionados con el ahorro y el uso eficiente de la energia electrica, han

  6. Electroosmotic pumps for microflow analysis

    Science.gov (United States)

    Wang, Xiayan; Wang, Shili; Gendhar, Brina; Cheng, Chang; Byun, Chang Kyu; Li, Guanbin; Zhao, Meiping; Liu, Shaorong

    2009-01-01

    With rapid development in microflow analysis, electroosmotic pumps are receiving increasing attention. Compared to other micropumps, electroosmotic pumps have several unique features. For example, they are bi-directional, can generate constant and pulse-free flows with flow rates well suited to microanalytical systems, and can be readily integrated with lab-on-chip devices. The magnitude and the direction of flow of an electroosmotic pump can be changed instantly. In addition, electroosmotic pumps have no moving parts. In this article, we discuss common features, introduce fabrication technologies and highlight applications of electroosmotic pumps. PMID:20047021

  7. Bearing for liquid metal pump

    International Nuclear Information System (INIS)

    Dickinson, R.J.; Pennell, W.E.; Wasko, J.

    1984-01-01

    A liquid metal pump bearing support comprises a series of tangentially oriented spokes that connect the bearing cylinder to the pump internals structure. The spokes may be arranged in a plurality of planes extending from the bearing cylinder to the pump internals with the spokes in one plane being arranged alternately with those in the next plane. The bearing support structure provides the pump with sufficient lateral support for the bearing structure together with the capability of accommodating differential thermal expansion without adversely affecting pump performance

  8. Thermo-electric pump

    International Nuclear Information System (INIS)

    Georges, J.-L.; Veyret, J.-F.

    1973-01-01

    Description is given of a thermo-pump for electrically conductive liquid fluids, e.g. for a liquid metal such as sodium. This pump is characterized in that the piping for the circulation of the conductive liquid is constituted by a plurality of conduits defined by two co-axial cylinders and two walls parallel to their axis. Each conduit limited outside by a magnet, inside by a mild-iron tube, and laterally by two materials forming a thermocouple. The electric current generated by that thermo-couple and the magnetic flux generated by the magnets both loop the loop through an outer cylindrical nickel shell. This can be applied to sodium circulation loops for testing nuclear fuel elements [fr

  9. Heat pumps: heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Pielke, R

    1976-01-01

    The author firstly explains in a general manner the functioning of the heat pump. Following a brief look at the future heat demand and the possibilities of covering it, the various methods of obtaining energy (making use of solar energy, ground heat, and others) and the practical applications (office heating, swimming pool heating etc.) are explained. The author still sees considerable difficulties in using the heat pump at present on a large scale. Firstly there is not enough maintenance personnel available, secondly the electricity supply undertakings cannot provide the necessary electricity on a wide basis without considerable investments. Other possibilities to save energy or to use waste energy are at present easier and more economical to realize. Recuperative and regenerative systems are described.

  10. Water displacement mercury pump

    Science.gov (United States)

    Nielsen, M.G.

    1984-04-20

    A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

  11. Pocket pumped image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, I.V., E-mail: kotov@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Murray, N. [Centre for Electronic Imaging, Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2015-07-01

    The pocket pumping technique is used to detect small electron trap sites. These traps, if present, degrade CCD charge transfer efficiency. To reveal traps in the active area, a CCD is illuminated with a flat field and, before image is read out, accumulated charges are moved back and forth number of times in parallel direction. As charges are moved over a trap, an electron is removed from the original pocket and re-emitted in the following pocket. As process repeats one pocket gets depleted and the neighboring pocket gets excess of charges. As a result a “dipole” signal appears on the otherwise flat background level. The amplitude of the dipole signal depends on the trap pumping efficiency. This paper is focused on trap identification technique and particularly on new methods developed for this purpose. The sensor with bad segments was deliberately chosen for algorithms development and to demonstrate sensitivity and power of new methods in uncovering sensor defects.

  12. FTU pump limiter

    International Nuclear Information System (INIS)

    Alessandrini, C.; Ciotti, M.; Mattei, A. De; Maddaluno, G.; Mazzitelli, G.

    1989-01-01

    The control of the refuelling and recycling of the plasma is crucial in providing enhanced performances in tokamaks and steady-state operation in future reactors. In this paper, we report details of the design and analysis for the pump limiter to be incorporated into the FTU tokamak. The FTU, presently under commissioning, is a compact high field (B=8T), medium high density, circular cross section machine with small accesses. The dimensions of the equatorial port (width 8 cm) would reduce the length of the entrance throat to a few centimeters, which is unacceptable for efficient particle trapping. We have, therefore, designed a rotating blade of the pump limiter head that, in the working position, extends in the toroidal direction inside the vacuum chamber. (author) 8 refs., 4 figs

  13. Geothermal heat pump

    International Nuclear Information System (INIS)

    Bruno, R.; Tinti, F.

    2009-01-01

    In recent years, for several types of buildings and users, the choice of conditioning by heat pump and low enthalpy geothermal reservoir has been increasing in the Italian market. In fact, such systems are efficient in terms of energy and consumption, they can perform, even at the same time, both functions, heating and cooling and they are environmentally friendly, because they do not produce local emissions. This article will introduce the technology and will focus on critical points of a geothermal field design, from actual practice, to future perspectives for the geo exchanger improvement. Finally, the article presents a best practice case in Bologna district, with an economic analysis showing the convenience of a geothermal heat pump. Conclusions of the real benefits of these plants can be drawn: compared to a non-negligible initial cost, the investment has a pay-back period almost always acceptable, usually less than 10 years. [it

  14. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  15. 14 CFR 23.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 23.991 Section 23.991... § 23.991 Fuel pumps. (a) Main pumps. For main pumps, the following apply: (1) For reciprocating engine installations having fuel pumps to supply fuel to the engine, at least one pump for each engine must be directly...

  16. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  17. IRRIGATION USING SOLAR PUMP

    OpenAIRE

    Prof. Nitin P.Choudhary*1 & Ms. Komal Singne2

    2017-01-01

    In this report the described design of a PV and soil moisture sensor based automated irrigation system is introduced. This project aims to provide a human friendly, economical and automated water pumping system which eliminates the problems of over irrigation and helps in irrigation water optimization and manage it in accordance with the availability of water. Our project not only tries to modernize the irrigation practices and ensure the optimum yield by carefully fulfilling the requirements...

  18. Small size ion pumps

    International Nuclear Information System (INIS)

    Cyranski, R.; Kiliszek, Cz.R.; Marks, J.; Sobolewski, A.; Magielko, H.

    2001-01-01

    This paper describes some designs of the two versions ion pumps and their range operation for various magnetic fields. The first version is made with different cell size in the anode element and titanium cathode operating in magnetic field from 600 to 650 Gs and the second version with the same anode element but differential Ti/Ta cathode working in magnetic field above 1200 Gs

  19. Design manual. [High temperature heat pump for heat recovery system

    Energy Technology Data Exchange (ETDEWEB)

    Burch, T.E.; Chancellor, P.D.; Dyer, D.F.; Maples, G.

    1980-01-01

    The design and performance of a waste heat recovery system which utilizes a high temperature heat pump and which is intended for use in those industries incorporating indirect drying processes are described. It is estimated that use of this heat recovery system in the paper, pulp, and textile industries in the US could save 3.9 x 10/sup 14/ Btu/yr. Information is included on over all and component design for the heat pump system, comparison of prime movers for powering the compressor, control equipment, and system economics. (LCL)

  20. Pumping potential wells

    Science.gov (United States)

    Hershkowitz, N.; Forest, C.; Wang, E. Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electro collecting anode in a relatively cold, low density multidipole plasma is considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important.

  1. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, all such structures must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well. Nevertheless, steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which pump ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density, multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two-dimensional character of the problem is shown to be important

  2. Pumping potential wells

    International Nuclear Information System (INIS)

    Hershkowitz, N.; Forest, C.; Wang, E.Y.; Intrator, T.

    1987-01-01

    Nonmonotonic plasma potential structures are a common feature of many double layers and sheaths. Steady state plasma potential wells separating regions having different plasma potentials are often found in laboratory experiments. In order to exist, such structures all must find a solution to a common problem. Ions created by charge exchange or ionization in the region of the potential well are electrostatically confined and tend to accumulate and fill up the potential well. The increase in positive charge should eliminate the well, but steady state structures are found in which the wells do not fill up. This means that it is important to take into account processes which 'pump' ions from the well. As examples of ion pumping of plasma wells, potential dips in front of a positively biased electron collecting anode in a relatively cold, low density multidipole plasma are considered. Pumping is provided by ion leaks from the edges of the potential dip or by oscillating the applied potential. In the former case the two dimensional character of the problem is shown to be important. (author)

  3. Jet operated heat pump

    International Nuclear Information System (INIS)

    Collard, T.H.

    1982-01-01

    A jet pump system is shown that utilizes waste heat to provide heating and/or cooling. Waste heat diverted through a boiler causes a refrigerant to evaporate and expand for supersonic discharge through a nozzle thereby creating a vacuum in an evaporator coil. The vacuum draws the refrigerant in a gaseous state into a condensing section of a jet pump along with refrigerant from a reservoir in a subcooled liquid form. This causes condensation of the gas in a condensation section of the jet pump, while moving at constant velocity. The change in momentum of the fluid overcomes the system high side pressure. Some of the condensate is cooled by a subcooler. Refrigerant in a subcooled liquid state from the subcooler is fed back into the evaporator and the condensing section with an adequate supply being insured by the reservoir. The motive portion of the condensate is returned to the boiler sans subcooling. By proper valving start-up is insured, as well as the ability to switch from heating to cooling

  4. Controlling groundwater pumping online.

    Science.gov (United States)

    Zekri, Slim

    2009-08-01

    Groundwater over-pumping is a major problem in several countries around the globe. Since controlling groundwater pumping through water flow meters is hardly feasible, the surrogate is to control electricity usage. This paper presents a framework to restrict groundwater pumping by implementing an annual individual electricity quota without interfering with the electricity pricing policy. The system could be monitored online through prepaid electricity meters. This provides low transaction costs of individual monitoring of users compared to the prohibitive costs of water flow metering and monitoring. The public groundwater managers' intervention is thus required to determine the water and electricity quota and watch the electricity use online. The proposed framework opens the door to the establishment of formal groundwater markets among users at very low transaction costs. A cost-benefit analysis over a 25-year period is used to evaluate the cost of non-action and compare it to the prepaid electricity quota framework in the Batinah coastal area of Oman. Results show that the damage cost to the community, if no active policy is implemented, amounts to (-$288) million. On the other hand, the implementation of a prepaid electricity quota with an online management system would result in a net present benefit of $199 million.

  5. Liquid sodium pumps

    International Nuclear Information System (INIS)

    Allen, H.G.

    1985-01-01

    The pump for use in a nuclear reactor cooling system comprises a booster stage impeller for drawing the liquid through the inlet. A diffuser is affixedly disposed within the pump housing to convert the kinetic pressure imparted to the liquid into increased static pressure. A main stage impeller is rotatively driven by a pump motor at a relatively high speed to impart a relatively high static pressure to the liquid and for discharging the liquid at a relatively high static pressure. A hydraulic coupling is disposed remotely from the liquid path for hydraulically coupling the main stage impeller and the booster stage impeller to rotate the booster stage impeller at a relatively low speed to maintain the low net positive suction pressure applied to the liquid at the inlet greater than the vapor pressure of the liquid and to ensure that the low net positive suction heat, as established by the main stage impeller exceeds the vapor pressure. The coupling comprises a grooved drum which rotates between inner and outer drag coupling members. In a modification the coupling comprises a torque converter. (author)

  6. Electrocentrifugal pumping; Bombeo electrocentrifugo

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perez, Guillermo; Medellin Otero, Hector [Instituto Mexicano del Peroleo (Mexico)

    1996-07-01

    The exploitation of isolated oil deposits, in losing their own energy, enter a phase of secondary recovery. One of the technologies of new development in Mexico is the one of electrocentrifugal pumping , which consists of introducing the motor-pump as an integral part of the production pipe down to the well bottom and pumping directly up to central complexes, from where it is sent inland. In the present paper is intended to explain what this type of secondary recovery consists of. [Spanish] La explotacion de yacimientos aislados de petroleo, al perder su energia propia, entran en una fase de recuperacion secundaria. Una de las tecnologias de nuevo desarrollo en Mexico es la de bombeo electrocentrifugo, la cual consiste en introducir la motobomba como parte integral de la tuberia de produccion hasta el fondo del pozo y bombearlo directamente hasta los complejos centrales, de donde se envia a tierra. En el presente trabajo se pretende explicar en que consiste este tipo de recuperacion secundaria.

  7. Optically pumped terahertz sources

    Institute of Scientific and Technical Information of China (English)

    ZHONG Kai; SHI Wei; XU DeGang; LIU PengXiang; WANG YuYe; MEI JiaLin; YAN Chao; FU ShiJie; YAO JianQuan

    2017-01-01

    High-power terahertz (THz) generation in the frequency range of0.1-10 THz has been a fast-developing research area ever since the beginning of the THz boom two decades ago,enabling new technological breakthroughs in spectroscopy,communication,imaging,etc.By using optical (laser) pumping methods with near-or mid-infrared (IR) lasers,flexible and practical THz sources covering the whole THz range can be realized to overcome the shortage of electronic THz sources and now they are playing important roles in THz science and technology.This paper overviews various optically pumped THz sources,including femtosecond laser based ultrafast broadband THz generation,monochromatic widely tunable THz generation,single-mode on-chip THz source from photomixing,and the traditional powerful THz gas lasers.Full descriptions from basic principles to the latest progress are presented and their advantages and disadvantages are discussed as well.It is expected that this review gives a comprehensive reference to researchers in this area and additionally helps newcomers to quickly gain understanding of optically pumped THz sources.

  8. Inspection device for buried equipment

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1994-01-01

    In an inspection device for a buried equipment, a rail is suspended at the upper portion of a vessel of a pit-vessel type pump buried in a plant building floor, and a truck movable vertical in the vessel along the rail, and an ultrasonic wave probe contained in the truck and urged to the vessel by an electromagnet are disposed. In addition, an elevator moving vertically along a shaft is disposed, and an arm having the ultrasonic probe disposed at the end portion and driven by a piston are disposed to the elevator. The ultrasonic wave probe moves vertically together with the truck along the rail in the vessel while being urged to the vessel by the electromagnet to inspect and measure the state at the inner and outer surfaces of the vessel. Further, the length of the arm is controlled so as to set a predetermined distance between the ultrasonic wave probe and the vessel. Subsequently, the elevator is moved vertically along a shaft passing through a shaft hole of a mount, and the shaft is rotated thereby enabling to inspect and measure the state of the inner and outer surfaces of the vessel. (N.H.)

  9. The satisfaction of developing a project of electrical energy saving; La satisfaccion de desarrollar un proyecto de ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arreola Suarez, Alejandro [Hotel Club Marival, Nuevo Vallarta, Nayarit (Mexico)

    2002-09-01

    The projects for the energy saving in hotels represent a great opportunity to reduce the operation costs in the demand and consumption of electrical energy, since the existing facilities can take advantage of new technologies in illumination, air conditioning, refrigeration and heating. By their constitution, the hotels work the year around uninterruptedly and must provide all type of services to the guests and working personnel, which originates that they consume great amounts of energy in air conditioning, lightning, laundry, etc., since the prestige of the installation depends on it. [Spanish] Los proyectos para el ahorro de energia en hoteles representan una gran oportunidad para reducir costos de operacion en la demanda y consumo de energia electrica, ya que las instalaciones existentes pueden aprovechar nuevas tecnologias en iluminacion, aire acondicionado, refrigeracion y calefaccion. Por su constitucion, los hoteles trabajan ininterrumpidamente todo el ano y deben proporcionar toda clase de servicios a los huespedes y personal que labora, lo cual origina que consuman grandes cantidades de energia en aire acondicionado, iluminacion, lavanderia, etc., pues de ello depende el prestigio de la instalacion.

  10. Energy saving in buildings through the elimination of typical problems; Ahorro de energia electrica en edificios a traves de la eliminacion de problemas tipicos

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Rivero, Alex G [Genertek, S. A. de C. V., Mexico, D. F. (Mexico)

    1994-12-31

    The enormous electric energy consumption in buildings represents an important area of saving opportunities. The design of installations without advanced technical illumination criteria, the absence of standardization over energy efficiency, the lack of observation of the existing standards and guides, the continuous load growth in existing installations and the lack of appropriate maintenance, are some of the causes of the inefficient use of electric energy in buildings. Although the problems, and consequently the solutions, are exclusive for each unit, some of the former are frequently repeated. In this paper the problems found along more than 40 audits conducted in large buildings of different types in Mexico city are commented. [Espanol] El enorme consumo de energia electrica en edificios representa una importante area de oportunidad para ahorro. El diseno de instalaciones sin criterios luminotecnicos avanzados, la ausencia de normalizacion sobre eficiencia energetica, la falta de observancia de las normas y recomendaciones vigentes, el continuo crecimiento de carga en instalaciones existentes y la falta de mantenimiento adecuado son algunas de las causas del uso ineficiente de la energia electrica en inmuebles. Aunque los problemas y por tanto las soluciones son particulares para cada unidad, algunos de los primeros se repiten frecuentemente. En este trabajo se comentan los problemas encontrados a lo largo de mas de 40 auditorias realizadas a inmuebles grandes de diversos tipos en la ciudad de Mexico.

  11. Ahorro infantil: “Chispitas”-Estrategia para combatir la pobreza, Fundación Ayú, Oaxaca, México

    Directory of Open Access Journals (Sweden)

    Guadalupe Arcos-Medina*

    2016-02-01

    Full Text Available En esta investigación analizamos cómo la estrategia de combate a la pobreza de la Fundación Ayú, influye en el hábito del ahorro de los niños y niñas mixtecos de Oaxaca -los “Chispitas”-, con datos obtenidos de noviembre de 2013 a julio de 2014. Realizamos un taller participativo y entrevistas semiestructuradas, aplicando un cuestionario a 42 niños y niñas de diez años de edad promedio, y antigüedad como ahorradores de entre tres y siete años. El perfil socioeconómico familiar corresponde mayormente a hogares campesinos; las razones para ahorrar son la educación, el futuro y las emergencias, siendo las madres quienes mayor influencia tienen en este hábito. Participar en las cajas visibiliza a los niños y niñas en la localidad y los inicia en la inclusión social y financiera.

  12. Composición quimicomineralógica de las materias primas y ahorro de energía en la industria del cemento

    Directory of Open Access Journals (Sweden)

    Soria Santamaría, Francisco

    1982-06-01

    Full Text Available In the field of energy saving, mainly thermic, in the cement industry, not only should we consider the possibilities in the technological process or the finished product, but also the influence of the chemical-mineral composition of the raw materials. The distinct parameters which fall into the reactivity of the crudes are analyzed, such as the size of the grain (fineness, chemical and mineral composition of the principal components. There follows an exposition of the importance of the minority components as smelting and mineralizers, finally emphasizing the interest and practical behaviour of some of them.

    En el campo del ahorro de energía, principalmente térmica, en la industria cementera, no sólo deben contemplarse las posibilidades en cuanto al proceso tecnológico o el producto acabado, sino también la influencia de la composición quimicomineralógica de las materias primas. Se analizan los distintos parámetros que inciden en la reactividad de los crudos, tales como tamaño de grano (finura, composición química y mineralogía de los componentes principales. A continuación se hace una exposición de la importancia de los componentes minoritarios como fundentes y mineralizadores, destacando finalmente el interés y comportamiento práctico de alguno de ellos.

  13. Actions and results of the management of energy saving of the CONDUMEX group; Acciones y resultados de la gerencia de ahorro de energia de grupo CONDUMEX

    Energy Technology Data Exchange (ETDEWEB)

    Sashida Key, Carlos; Jimenez Huerta, Arturo; Alavez Alcazar, Moises [Grupo Condumex, Industrias IEM, S.A. de C.V., Mexico, D.F. (Mexico)

    1999-07-01

    The purpose of this paper is to expose some practical cases that have been developed through the Energy Saving Management of GRUPO CONDUMEX, in different areas such as systems related to water, steam, electricity and compressed air. This experience has been compiled of diagnoses and actions that have been carried out in the companies inside and outside GRUPO CONDUMEX, and of systems with the purpose of making efficient the use of fuels and getting close to the energy indexes that are handled in other International companies of the same manufacture branch. [Spanish] Este trabajo tiene por objeto exponer algunos casos practicos que se han desarrollado a traves de la Gerencia de Ahorro de Energia de GRUPO CONDUMEX, en distintas areas tales como sistemas relacionados con agua, vapor, electricidad y aire comprimido. Esta experiencia ha sido recopilada de diagnosticos y acciones que se han llevado a cabo en las empresas dentro y fuera de GRUPO CONDUMEX, y de sistemas con la finalidad de eficientar el uso de los energeticos y acercarnos a los indices energeticos que se manejan en otras empresas internacionales del mismo ramo de fabricacion.

  14. Ahorro infantil: “Chispitas”-Estrategia para combatir la pobreza, Fundación Ayú, Oaxaca, México

    Directory of Open Access Journals (Sweden)

    Guadalupe Arcos-Medina

    2016-01-01

    Full Text Available En esta investigación analizamos cómo la estrategia de combate a la pobreza de la Fundación Ayú, influye en el hábito del ahorro de los niños y niñas mixtecos de Oaxaca -los "Chispitas"-, con datos obtenidos de noviembre de 2013 a julio de 2014. Realizamos un taller participativo y entrevistas semiestructuradas, aplicando un cuestionario a 42 niños y niñas de diez años de edad promedio, y antigüedad como ahorradores de entre tres y siete años. El perfil socioeconómico familiar corresponde mayormente a hogares campesinos; las razones para ahorrar son la educación, el futuro y las emergencias, siendo las madres quienes mayor influencia tienen en este hábito. Participar en las cajas visibiliza a los niños y niñas en la localidad y los inicia en la inclusión social y financiera.

  15. Administración estratégica y gobernabilidad en las cooperativas de ahorro y crédito del cantón Portoviejo

    Directory of Open Access Journals (Sweden)

    Dianexy Viviana Carreño

    2014-12-01

    Full Text Available Las Cooperativas de Ahorro y Crédito (CAC’s tienen una activa participación en el crecimiento y desarrollo económico del Ecuador, lo que permite desarrollar un estudio en la provincia de Manabí, tomando una muestra deliberada en el cantón Portoviejo, que concentra el 40% de las cooperativas que operan en la provincia; se utilizó la encuesta como técnica de recolección de datos, y se aplicó a los gerentes, presidentes de los Consejos de Administración y de vigilancia de diez CAC’s; A modo de conclusión es necesario recomendar promover el fortalecimiento y expansión con carácter holístico, a través de capacitación permanente y puesta en práctica de la Administración Estratégica, para alcanzar una mejor posición en el mercado, ganar la lealtad de los socios y atraer nuevos miembros.

  16. Energy saving in buildings through the elimination of typical problems; Ahorro de energia electrica en edificios a traves de la eliminacion de problemas tipicos

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Rivero, Alex G. [Genertek, S. A. de C. V., Mexico, D. F. (Mexico)

    1993-12-31

    The enormous electric energy consumption in buildings represents an important area of saving opportunities. The design of installations without advanced technical illumination criteria, the absence of standardization over energy efficiency, the lack of observation of the existing standards and guides, the continuous load growth in existing installations and the lack of appropriate maintenance, are some of the causes of the inefficient use of electric energy in buildings. Although the problems, and consequently the solutions, are exclusive for each unit, some of the former are frequently repeated. In this paper the problems found along more than 40 audits conducted in large buildings of different types in Mexico city are commented. [Espanol] El enorme consumo de energia electrica en edificios representa una importante area de oportunidad para ahorro. El diseno de instalaciones sin criterios luminotecnicos avanzados, la ausencia de normalizacion sobre eficiencia energetica, la falta de observancia de las normas y recomendaciones vigentes, el continuo crecimiento de carga en instalaciones existentes y la falta de mantenimiento adecuado son algunas de las causas del uso ineficiente de la energia electrica en inmuebles. Aunque los problemas y por tanto las soluciones son particulares para cada unidad, algunos de los primeros se repiten frecuentemente. En este trabajo se comentan los problemas encontrados a lo largo de mas de 40 auditorias realizadas a inmuebles grandes de diversos tipos en la ciudad de Mexico.

  17. Development of a mercury electromagnetic centrifugal pump for the SNAP-8 refractory boiler development program

    Science.gov (United States)

    Fuller, R. A.; Schnacke, A. W.

    1974-01-01

    An electromagnetic pump, in which pressure is developed in mercury because of the interaction of the magnetic field and current which flows as a result of the voltage induced in the mercury contained in the pump duct, was developed for the SNAP-8 refractory boiler test facility. Pump performance results are presented for ten duct configurations and two stator sizes. These test results were used to design and fabricate a pump which met the SNAP-8 criteria of 530 psi developed pressure at 12,500 lb/hr. The pump operated continuously for over 13,000 hours without failure or performance degradation. Included in this report are descriptions of the experimental equipment, measurement techniques, all experimental data, and an analysis of the electrical losses in the pump.

  18. Multiphase pumping: indoor performance test and oilfield application

    Science.gov (United States)

    Kong, Xiangling; Zhu, Hongwu; Zhang, Shousen; Li, Jifeng

    2010-03-01

    Multiphase pumping is essentially a means of adding energy to the unprocessed effluent which enables the liquid and gas mixture to be transported over a long distances without prior separation. A reduction, consolidation, or elimination of the production infrastructure, such as separation equipments and offshore platforms can be developed more economically. Also it successfully lowed the backpressure of wells, revived dead wells and improved the production and efficiency of oilfield. This paper reviews the issues related to indoor performance test and an oilfield application of the helico-axial multiphase pump designed by China University of Petroleum (Beijing). Pump specification and its hydraulic design are given. Results of performance testing under different condition, such as operational speed and gas volume fraction (GVF) etc are presented. Experimental studies on combination of theoretical analysis showed the multiphase pump satisfies the similitude rule, which can be used in the development of new MPP design and performance prediction. Test results showed that rising the rotation speed and suction pressure could better its performance, pressure boost improved, high efficiency zone expanding and the flow rate related to the optimum working condition increased. The pump worked unstable as GVF increased to a certain extent and slip occurred between two phases in the pump, creating surging and gas lock at a high GVF. A case of application in Nanyang oilfield is also studied.

  19. Report on the results of the FY 1999 R and D of the medical welfare equipment technology and the development of an implantable total artificial heart system using a non-pulsatile pump. R and D of an implantable total artificial heart system using a non-pulsatile pump (R and D of the functional/cure artificial heart); Iryo fukushi kiki gijutsu no kenkyu kaihatsu tainai umekomigata jinko shinzo system 1999 nendo seika hokokusho. 5. Renzokuryu pump wo mochiita tainai umekomigata jinko shinzo system no kenkyu kaihatsu (kinoteki chiryoteki jinko shinzo no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The R and D of element technology were made on non-pulsatile pump, drive/controller, energy supply storage system, structural coating materials, etc., and the prescribed target was achieved. In the R and D of a total system, a blood-removing conduit with movability was designed to avoid the functional inlet obstruction, and the animal experiment was carried out. In the short-term chronic animal experiment on the implantation of a single bypass model using this artificial conduit and in the animal experiment for implantation of functional/cure artificial heart, it was confirmed that the operation was conducted easily, the flow rate of the blood of the artificial heart is extremely stable, and the blood-removing conduit functions favorably. In the R and D on Tele-TAH with the aim of future home medical treatment, it became possible to acquire via monitor the pump drive information and blood circulation state information on the animals tested in the breeding farm. The remote medical simulation was made. (NEDO)

  20. Energy saving using solar filters with iron base in windows; Ahorro de energia usando filtros solares con base en hierro en ventanas

    Energy Technology Data Exchange (ETDEWEB)

    Chavez Galan, Jesus

    2003-07-01

    termico generado al interior de las edificaciones por las inadecuadas propiedades de los materiales de construccion, se desarrollaron en este trabajo filtros solares con base en hierro por medio de los cuales se logra un control selectivo de la radiacion solar que se transmite a traves de las ventanas. Estos filtros solares consisten en peliculas delgadas de FeO depositadas sobre sustratos de vidrio cal-sosa (el mas usado en nuestro pais para las edificaciones) de 600x300x3 mm, por medio de la tecnica de sputtering asistida con radiofrecuencia y magnetrones planos, partiendo de un blanco de hierro puro de 127x254 mm y usando un plasma de argon. Para obtener el grado de oxidacion deseado en el hierro, pequenas muestras (45 x 22 mm) fueron sometidas a un proceso de calentamiento en una atmosfera reductora constituida de 50% H{sub 2} + 50% N{sub 2}, durante un periodo de tiempo de 10 minutos a una temperatura de 400 C. Los filtros solares con base en FeO presentan una transmisividad de 30.2% para el intervalo visible del espectro electromagnetico (radiacion con longitud de onda de 380-780 nm), y de 39.9% para el infrarrojo cercano (radiacion con longitud de onda de 780-2500 nm); mientras que su reflectividad es de 17.5 y 19%, para los intervalos visibles e infrarrojo cercano del espectro electromagnetico respectivamente. Se realizo una simulacion, a traves del software Energy 10, del comportamiento energetico de una casa-habitacion cuando utilizan en las ventanas vidrios simples (una lamina) tipo cal-sosa, asi como tambien cuando esta misma edificacion usa en las ventanas los filtros solares con base en FeO desarrollados. Ambos casos se comparan obteniendose asi los posibles ahorros de energia por el uso de dichos filtros solares en las ventanas. Las simulaciones fueron llevadas a cabo para diferentes localidades del pais, obteniendose que los filtros solares con base en FeO desarrollados, permiten ahorros de energia principalmente por concepto de acondicionamiento de aire

  1. HVAC systems and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.T. (Linford Air and Refrigeration Company, Oakland, CA (US))

    1990-02-01

    The author discusses the section of the ASHRAE Standard 90.1-1989 which addresses HVAC systems and equipment. New features of HVAC systems mandatory general requirements are described. New prescriptive requirements are detailed.

  2. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  3. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  4. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  5. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  6. The EU directive for eco-design of circulation pumps; Die EG-Verordnung fuer die umweltgerechte Gestaltung von Umwaelzpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Schuberth, Jens [Umweltbundesamt, Dessau (Germany); Akkermann, Floris [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2009-05-15

    The EU directive belongs to a bundle of measures concerning electrical equipment such as circulation pumps, heating systems, electric motors, filament bulbs and refrigerators. It was issued with the intention to significantly reduce energy consumption of these appliances. (AKB)

  7. On-line PWR RHR pump performance testing following motor and impeller replacement

    International Nuclear Information System (INIS)

    DiMarzo, J.T.

    1996-01-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump's 'B' impeller. The spare was installed into the 'B' train. The motor had never been run in the system before. A pump performance test was developed to verify it's operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the 'B' Train showed performance well in excess of the minimum required. The motor that was originally in the 'B' train was similarly overhauled and equipped with 'A' pump's original impeller, re-installed in the 'A' train, and tested. Analysis of the 'A' train results indicate that the RHR pump's performance was also well in excess of the vendors requirements

  8. Sodium cleaning device for nuclear reactor equipments

    International Nuclear Information System (INIS)

    Fujisawa, Morio.

    1985-01-01

    Purpose: To enable sodium cleaning over the entire length of large size equipments such as control rod drives and primary coolant recycling pumps for use in FBR type reactors. Constitution: A plurality of warm water supply nozzles each having a valve are connected at varying height on the side of a cleaning tank, to which an exhaust line is connected. These nozzles are connected with an exhaust port at the bottom of the tank to constitute a pipeway for cleaning warm water recycling line including a water feed pump and a feedwater heater. The water level in the tank is changed stepwise by successively selecting the warm water feed nozzles. Further, the warm water in the tank is recyclically fed through the nozzles selected at each step of the water level through the recycle line while warming. On the other hand, the pressure inside the tank is reduced through the exhaust line, whereby the warm water in the tank is boiled at low temperature to clean-up sodium on the equipments to be cleaned over the entire length. (Horiuchi, T.)

  9. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    OpenAIRE

    Li, Tao; Zhang, Weiming; Jiang, Ming; Li, Zhengyang

    2013-01-01

    A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Re...

  10. 33 CFR 150.531 - How many fire pumps must be kept ready for use at all times?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How many fire pumps must be kept ready for use at all times? 150.531 Section 150.531 Navigation and Navigable Waters COAST GUARD... Specialty Equipment Miscellaneous Operations § 150.531 How many fire pumps must be kept ready for use at all...

  11. Evaluation of Failed Crane Chempumps Used During Salt Well Pumping

    International Nuclear Information System (INIS)

    ELSEN, J.J.

    2000-01-01

    The Interim Stabilization Project is responsible for removing pumpable interstitial liquid from remaining single shelled tanks and transferring the waste to safer double-shelled tanks. This waste transfer is conducted by installing a saltwell pumping system within the designated single shell tank, and transferring the waste to double shelled tank using approved transfer lines. The saltwell pumping system is placed within a saltwell screen installed into the tank waste, the screen is designed to allow gravity flow of liquid into the screen and prevent solids from entering the pumping system. A foot valve consisting of a venturi jet and nozzle creates a suction, picking up waste at an equal rate as the out flow transfer rate of the saltwell system. A centrifugal pump is used to create the motive force across the eductor and drive the waste through the associated system piping and transfer lines leading to the double shelled tanks. The centrifugal pump that has typically been used in the saltwell pumping system installations is the Crane Chempump, model GA-1 1/2 K with 4 3/4 inch impeller. The following evaluation is not intended to be an all inclusive analysis of the operation of a saltwell system and associated pump. This evaluation will detail some of the noted failures in specific saltwell systems and document those findings. Due to the large number of saltwell systems installed over the duration of the Stabilization Project, only those saltwell systems installed over the last two years within S, SX, U, A and AX tank farms, shall be included in this evaluation. After identification of the pump failures mechanism, recommendations shall be identified to address potential means of improving overall operational efficiency and reducing overall equipment failures

  12. Canned motor pumps at Heavy Water Project, Baroda [Paper No.: II-2

    International Nuclear Information System (INIS)

    Batra, R.K.; Waishampayan, S.G.

    1981-01-01

    Heavy Water Project, Baroda is having special canned motor pumps for pumping ammonia and potassium amide. These pumps work under a pressure of 640 kg/cm 2 and are lubricated and cooled by the same fluid. These pumps are having special bearings consisting of mating surfaces of tungsten carbine Vs ceramic or stellite Vs carbon depending upon application. The total number of such pumps installed in the plant is around 52. These pumps being installed in high pressure vessels working at a pressure of 640 kg/cm 2 have special maintenance problems and need special care during maintenance. Pumps once boxed up are completely out of reach for immediate maintenance if needed. The failure of these pumps may mean a down time of one to two months for the plant. Besides above, there are multistage barrel type ammonia pumps with 24 stages developing a pressure of 140 kg/cm 2 . All these equipments need special maintenance methods as the problems faced are varied and difficult to solve. This paper deals with general and unique type of problems faced on these pumps. (author)

  13. Diode laser pumping

    International Nuclear Information System (INIS)

    Skagerlund, L.E.

    1975-01-01

    A diode laser is pumped or pulsed by a repeated capacitive discharge. A capacitor is periodically charged from a dc voltage source via a transformer, the capacitor being discharged through the diode laser via a controlled switching means after one or more charging periods. During a first interval of each charging period the transformer, while unloaded, stores a specific amount of energy supplied from the dc voltage source. During a subsequent interval of the charging period said specific amount of energy is transmitted from the transformer to the capacitor. The discharging of the capacitor takes place during a first interval of a charging period. (auth)

  14. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topolgies are suggested which allow high erosion without limiter failure

  15. Novel limiter pump topologies

    International Nuclear Information System (INIS)

    Schultz, J.H.

    1981-01-01

    The use of limiter pumps as the principle plasma exhaust system of a magnetic confinement fusion device promises significant simplification, when compared to previously investigating divertor based systems. Further simplifications, such as the integration of the exhaust system with a radio frequency heating system and with the main reactor shield and structure are investigated below. The integrity of limiters in a reactor environment is threatened by many mechanisms, the most severe of which may be erosion by sputtering. Two novel topologies are suggested which allow high erosion without limiter failure

  16. Improvements relating to electromagnetic pumps

    International Nuclear Information System (INIS)

    Davidson, D.F.

    1975-01-01

    Reference is made to electromagnetic pumps suitable for use in pumping molten Na, and particularly to annular linear induction pumps that may for example be used to pump molten Na at temperatures up to 650 0 in situations where it is not possible to provide cooling. Previous designs of such pumps have employed disk-shaped coils around the outside of the annulus, the coils being energised from a three-phase power supply to produce a travelling radial field. The pump system described obviates the necessity for joints between the coils. It also allows the use of all types of high temperature insultation, simplified manufacture, and enables the windings to be located on the inside of the annulus. Full constructional details are given. (U.K.)

  17. Fast breeder reactor electromagnetic pump

    International Nuclear Information System (INIS)

    Araseki, Hideo; Murakami, Takahiro

    2008-01-01

    Main pumps circulating sodium in the FBR type reactor have been mechanical types, not electromagnetic pumps. Electromagnetic pump of 1-2 m 3 /min has been used as an auxiliary pump. Large sized electromagnetic pumps such as several hundred m 3 /min have not been commercialized due to technical difficulties with electromagnetic instability and pressure pulsations. This article explained electromagnetic and fluid equations and magnetic Reynolds number related with electromagnetic pumps and numerical analysis of instability characteristics and pressure pulsations and then described applications of the results to FBR system. Magnetic Reynolds number must be chosen less than one with appropriate operating frequency and optimum slip of 0.2-0.4. (T. Tanaka)

  18. Mechanical pumping at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1994-12-31

    This new concept consists of a mechanical pump able to run at low temperature (25 K). Since gas density varies inversely with temperature, the pump could deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are reduction of an order of magnitude in size and weight when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. Results obtained at 80 K and 25 K with a Holweck type molecular drag pump of 100 mm diameter and with few stages of a turbomolecular pump running at the same temperatures, are given. This pump would be a solution to allow continuous tritium extraction and minimize the mass inventory for the ITER (International Tokamak Experiment Reactor). 5 figs., 2 tabs., 4 refs.

  19. Centrifugal pumps: fundamentals and classification

    International Nuclear Information System (INIS)

    Solar Manuel, A. M.

    2009-01-01

    Centrifugal pumps are usually employed to impulse water to elevate it, dose it or give it pressure or speed. They can be used with clean water or loaded with high solid concentration and don't work properly with air or another gas flow. There are another less used pumps, coming from volumetric or ram pumps to magnetic ones for specific uses. Centrifugal ones are rotokinetic pumps, like peripherical or lateral channel pumps. They work in a different way that non rotational kinetic ones and static ones. The work approaches their pre definition, selection, installation, operation and maintenance. It also review their morphology, hidromechanic principles and the basic elements pumps are made of. (Author)

  20. Report on an investigation into heat pumps in China in fiscal 1995; 1995 nendo Chugoku ni okeru heat pump system ni kansuru chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    The paper surveyed the present status, the status of spread, and the technical development of the technology of heat pumps for residential and industrial uses in China. Main examples of installation of heat pumps are cited below: steam drive absorption type refrigerators in Beijing; sea water heat source turbo heat pumps in Qingdao; hot water drive absorption type refrigerators in Beijing; oil-fueled absorption type water cooling and heating appliances in Beijing; ice latent heat storage airconditioning systems using electrically-driven screw chiller in Beijing; temperature rising systems using electrically-driven heat pump of the solar energy utilization warm water swimming pool in Guangdong Province; cooling water supply using waste heat utilization absorption type refrigerator of the alcohol plant in Shandong Province; timber drying systems using electrically-driven heat pump, and marine product cultivation systems in Quangdong Province; distillation systems using steam turbine heat pump in Jiangxi Province. The demand for heat pumps is expected to be 20 million units under the 9th 5-year plan, and the development of equipment is thought to go toward promotion of energy conservation, low noise, multi-type or multi-functional air conditioning equipment, and computer use. 137 figs., 40 tabs.

  1. Considerations for reference pump curves

    International Nuclear Information System (INIS)

    Stockton, N.B.

    1992-01-01

    This paper examines problems associated with inservice testing (IST) of pumps to assess their hydraulic performance using reference pump curves to establish acceptance criteria. Safety-related pumps at nuclear power plants are tested under the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (the Code), Section 11. The Code requires testing pumps at specific reference points of differential pressure or flow rate that can be readily duplicated during subsequent tests. There are many cases where test conditions cannot be duplicated. For some pumps, such as service water or component cooling pumps, the flow rate at any time depends on plant conditions and the arrangement of multiple independent and constantly changing loads. System conditions cannot be controlled to duplicate a specific reference value. In these cases, utilities frequently request to use pump curves for comparison of test data for acceptance. There is no prescribed method for developing a pump reference curve. The methods vary and may yield substantially different results. Some results are conservative when compared to the Code requirements; some are not. The errors associated with different curve testing techniques should be understood and controlled within reasonable bounds. Manufacturer's pump curves, in general, are not sufficiently accurate to use as reference pump curves for IST. Testing using reference curves generated with polynomial least squares fits over limited ranges of pump operation, cubic spline interpolation, or cubic spline least squares fits can provide a measure of pump hydraulic performance that is at least as accurate as the Code required method. Regardless of the test method, error can be reduced by using more accurate instruments, by correcting for systematic errors, by increasing the number of data points, and by taking repetitive measurements at each data point

  2. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  3. IRRIGATION STATION EQUIPMENT FOR PREVENTING THE USE OF LOW WATER QUALITY

    Directory of Open Access Journals (Sweden)

    Constantin Nicolescu

    2010-01-01

    Full Text Available In Romania the economically efficient irrigated area is estimated at 3.5 million hectares. On national scale there is nointegrated approach for monitoring the quantity and quality of the irrigation water, using adequate equipment at thepumping station. On international scale, in many countries the pumping stations are provided with equipment formonitoring, on real time, the quality or the pumped water and for warning about critical situations (emergencies.This paper describes a technical solution consisting of equipment which monitors the following parameters of waterpumped in irrigation systems: turbidity, pH, CE at 25 o C, Na+, Cl-. The lapse of time for monitoring is of 10 to 60 min.The main components are the following: the sampling pump (submersible the monitoring board, the repression pipe ofthe analyzed water. Warnings are made about values exceeding the programmed level for each monitored parameter,about the fact that the pump and agitator do not work or about any other source of damage.The technical solution and equipment were tested at a pumping station which uses water from Danube, in most casesmixed with water originating from drainage. Results showed a reduction of the total content of soluble salts from soiland of their negative impact upon the crops, a reduction of the degree of river alluvial deposits within the irrigationsystem and reduction of the energetic consumption required for pumping.

  4. Effect of pump limiter throat on pumping efficiency

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-01-01

    The necessary control of plasma edge density has led to the development of pump limiters to achieve this task. On Tore Supra, where a large part of the program is devoted to plasma edge studies, two types of such density control apparatus have been implemented, a set of pump limiters and the pumps associated to the ergodic divertor (magnetically assisted pump limiters). Generally two different kinds of pump limiters can be used, those with a throat which drives the plasma from the open edge plasma (SOL) to the neutralizer plate, and those without or with a very short throat. We are interested here in this aspect of the pump limiter concept, i.e. on the throat effect on neutral density build-up in the vicinity of the pumping plates (and hence on pumping efficieny). The underlying idea of this throat effect can be readily understood; indeed while the neutral capture in pump limiters without throats is only a ballistic effect, on expects the plasma to improve the efficiency of pump-limiters via plasma-neutral-sidewall interactions in the throat. This problem has been studied both numerically and analytically. The paper is divided as follows. In section 2, we describe the basic features of pump-limiters which are modelized by the numerical code Cezanne. Section 3 is devoted to the throat length effect considering in particular the neutral density profile in the throat and the neutral density buil-up as a function of the throat lenght. In section 4, we show that the plugging effect occurs for reasonnable values of throat lengths. An analytical value of the plugging length is discussed and compared to the values obtained numerically

  5. Mechanical pumping at low temperature

    International Nuclear Information System (INIS)

    Perin, J.P.; Claudet, G.; Disdier, F.

    1995-01-01

    This novel concept consist of a mechanical pump able to run at low temperature (25K). Since gas density varies inversely with temperature, this pump would deliver much higher mass flow rate than at room temperature for a given size. Advantages of this concept are order of magnitude reduction in size, weight, when compared to a conventional pump scaled to perform the same mass flow rate at room temperature. This pump would be a solution to allow continuously tritium extraction and minimize the mass inventory. (orig.)

  6. Proper Sizing of Circulation Pumps

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Nørgaard, Jørgen

    2007-01-01

    The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust, but the r......The paper describes the preliminary results from field tests of replacing various types of old pumps used for circulating water in heating systems in single- and double-family houses with new types of pumps. The tests were carried out in Denmark for the Danish Electricity Savings Trust...

  7. High-vacuum plasma pump

    International Nuclear Information System (INIS)

    Dorodnov, A.M.; Minajchev, V.E.; Miroshkin, S.I.

    1980-01-01

    The action of an electric-arc high-vacuum pump intended for evacuating the volumes in which the operation processes are followed by a high gas evolution is considered. The operation of the pump is based on the principle of controlling the getter feed according to the gas load and effect of plasma sorbtion pumping. The pump performances are given. The starting pressure is about 5 Pa, the limiting residual pressure is about 5x10 -6 Pa, the pumping out rate of nitrogen in the pressure range 5x10 -5 -5x10 -3 Pa accounts for about 4000 l/s, the power consumption comes to 6 kW. Analyzing the results of the test operation of the pump, it has been concluded that its principal advantages are the high starting pressure, controlled getter feed rate and possibility of pumping out the gases which are usually pumped out with difficulty. The operation reliability of the pump is defined mainly by reliable operation of the ignition system of the vacuum arc [ru

  8. Examination of pump failure data in the nuclear power industry

    International Nuclear Information System (INIS)

    Casada, D.

    1996-01-01

    There are several elements that are critical to any program which is used to optimize the availability and reliability of process equipment. Perhaps the most important elements are routine monitoring and predictive maintenance elements. In order to optimize equipment monitoring and predictive maintenance, it is necessary to fundamentally and thoroughly understand the principal failure modes for the equipment and the effectiveness of alternative monitoring methods. While these observations are general in nature, they are certainly true for the open-quotes heartclose quotes of fluid systems - pumps. In recent years, particularly within the last decade, the capabilities and ease of use of previously existing pump diagnostic technologies, such as vibration monitoring and oil analysis, have improved dramatically. Newer technologies, such as thermal imaging, have been found effective at detecting certain undesirable or degraded conditions, such as misalignment and overheated bearings or packing. The ASME Code and NRC regulatory requirements have been, like essentially all similar code and regulatory bodies, conservative in their adoption or endorsement of newer technologies. The requirements prescribed by the Code and endorsed by the NRC have, in their essence, changed only minimally over more than a dozen years. As a follow-on to studies of check valve failure experience in the nuclear industry that have proven useful in identifying the effectiveness of alternative monitoring methods, a study of nuclear industry pump failure data has been conducted. The results of this study, conducted for the NRC by Oak Ridge National Laboratory, are presented. The historical effectiveness of both regulatory required and voluntarily implemented pump monitoring programs are shown. The distribution of pump failures by application, affected area, and level of significance are indicated. Apparent strengths and weaknesses of alternative monitoring methods are discussed

  9. Examination of pump failure data in the nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1996-12-01

    There are several elements that are critical to any program which is used to optimize the availability and reliability of process equipment. Perhaps the most important elements are routine monitoring and predictive maintenance elements. In order to optimize equipment monitoring and predictive maintenance, it is necessary to fundamentally and thoroughly understand the principal failure modes for the equipment and the effectiveness of alternative monitoring methods. While these observations are general in nature, they are certainly true for the {open_quotes}heart{close_quotes} of fluid systems - pumps. In recent years, particularly within the last decade, the capabilities and ease of use of previously existing pump diagnostic technologies, such as vibration monitoring and oil analysis, have improved dramatically. Newer technologies, such as thermal imaging, have been found effective at detecting certain undesirable or degraded conditions, such as misalignment and overheated bearings or packing. The ASME Code and NRC regulatory requirements have been, like essentially all similar code and regulatory bodies, conservative in their adoption or endorsement of newer technologies. The requirements prescribed by the Code and endorsed by the NRC have, in their essence, changed only minimally over more than a dozen years. As a follow-on to studies of check valve failure experience in the nuclear industry that have proven useful in identifying the effectiveness of alternative monitoring methods, a study of nuclear industry pump failure data has been conducted. The results of this study, conducted for the NRC by Oak Ridge National Laboratory, are presented. The historical effectiveness of both regulatory required and voluntarily implemented pump monitoring programs are shown. The distribution of pump failures by application, affected area, and level of significance are indicated. Apparent strengths and weaknesses of alternative monitoring methods are discussed.

  10. Design of the RTO/RC ITER primary pumping system

    International Nuclear Information System (INIS)

    Ladd, P.; Ibbott, C; Janeschitz, G.; Martin, E.

    2000-01-01

    The primary pumping system is needed not only to exhaust helium ash resulting from the DT reaction but also excess fuelling gas injected during the fusion burn, which can extend for 100's to 1000's of seconds, and to perform a variety of other functions. The prevailing environmental conditions, principally nuclear radiation, tritium exposure, magnetic fields, and the need for containment, have a significant impact on the design and selection of equipment. This paper presents the design of the Reduced Technical Objectives/Reduced Cost (RTO/RC) ITER primary pumping system with particular emphasis on the nuclear aspects of the design. Component selection and equipment layout issues to meet established requirements for the system are reviewed together with the R and D that is being undertaken to support the design. In addition, serviceability and maintainability issues related to this system are also discussed

  11. Device for covering a string of pump-compressor pipes

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Prokopov, O.I.; Rastorgyev, M.A.

    1982-01-01

    The invention refers to oil field equipment, and more specifically to devices for automatic coverage of the flow of gusher oil and gas wells during the development of a fire near the well. A device is described for covering the string of pump-compressor pipes which includes a housing with piston connected to the string of pump-compressor pipes, shoe, seat and assembly for fixing the piston in the upper position with heat-sensitive substance. It is distinguished by the fact that in order to improve reliability of its triggering when a fire develops, the assembly for fixing the piston is equipped with hydraulic cylinders whose rods are connected to the piston, and the heat sensitive substance is placed in the vessels whose cavities are connected to the above-piston cavities of the hydraulic cylinders and are connected by a common collector.

  12. RELIABILITY MODELING BASED ON INCOMPLETE DATA: OIL PUMP APPLICATION

    Directory of Open Access Journals (Sweden)

    Ahmed HAFAIFA

    2014-07-01

    Full Text Available The reliability analysis for industrial maintenance is now increasingly demanded by the industrialists in the world. Indeed, the modern manufacturing facilities are equipped by data acquisition and monitoring system, these systems generates a large volume of data. These data can be used to infer future decisions affecting the health facilities. These data can be used to infer future decisions affecting the state of the exploited equipment. However, in most practical cases the data used in reliability modelling are incomplete or not reliable. In this context, to analyze the reliability of an oil pump, this work proposes to examine and treat the incomplete, incorrect or aberrant data to the reliability modeling of an oil pump. The objective of this paper is to propose a suitable methodology for replacing the incomplete data using a regression method.

  13. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  14. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  15. Resonant Tunneling Spin Pump

    Science.gov (United States)

    Ting, David Z.

    2007-01-01

    The resonant tunneling spin pump is a proposed semiconductor device that would generate spin-polarized electron currents. The resonant tunneling spin pump would be a purely electrical device in the sense that it would not contain any magnetic material and would not rely on an applied magnetic field. Also, unlike prior sources of spin-polarized electron currents, the proposed device would not depend on a source of circularly polarized light. The proposed semiconductor electron-spin filters would exploit the Rashba effect, which can induce energy splitting in what would otherwise be degenerate quantum states, caused by a spin-orbit interaction in conjunction with a structural-inversion asymmetry in the presence of interfacial electric fields in a semiconductor heterostructure. The magnitude of the energy split is proportional to the electron wave number. Theoretical studies have suggested the possibility of devices in which electron energy states would be split by the Rashba effect and spin-polarized currents would be extracted by resonant quantum-mechanical tunneling.

  16. Device for overlapping of a column of pump compressor pipes

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Akhmerov, M.N.; Asadullin, Kh.F.; Prokopov, O.I.

    1980-02-16

    A device is proposed for automatic overlapping of pump compressor pipes of gushing petroleum and gas wells when losses occur near the well. The objective of the invention is to increase efficiency of the overlapping of the pipe column by recharging the device directly at the hole without disassembling the head equipment. This objective is achieved as follows. The device is equipped with elastic spacers located in the channels of a ring. They are mounted with the possibility of interaction with ball catches. A drawing and description of the device are given.

  17. Ahorros en los consumos para enfriamiento de espacios interiores mediante la evaluación de sistemas de protección solar en edificios residenciales en altura. El caso de la "ciudad-oasis" de Mendoza, Argentina

    Directory of Open Access Journals (Sweden)

    Julieta Balter

    2016-06-01

    Full Text Available El presente trabajo estudia el comportamiento térmico y energético de edificios residenciales en altura, en el contexto particular de una “ciudad-oasis”. Se plantea como objetivo la definición de sistemas de control solar adecuados en la envolvente para cada tipología material de edificio -másica y liviana- y para cada estrato en altura de las viviendas: debajo y sobre de la copa de los árboles. El monitoreo de viviendas en uso permite validar modelos geométricos (software Energy Plus y simular propuestas de aplicación de elementos de protección solar. Se analizan los ahorros en los consumos para enfriamiento en departamentos en niveles bajos, medios y altos. Los resultados muestran que en el edificio másico, en las viviendas ubicadas debajo de la copa de los árboles, es posible anular las cargas energéticas para enfriamiento mediante el uso de elementos exteriores de protección solar. Mientras que en las viviendas sobre la copa de los árboles, los ahorros energéticos se encuentran entre el 32% y 42%. En el edificio liviano, la aplicación de sistemas de control en departamentos bajo la copa de los árboles alcanza ahorros del orden del 53% y en las viviendas sobre la copa, las reducciones energéticas se encuentran entre el 46% y 54%. Las dimensiones adecuadas de tales elementos pueden generar propuestas posibles de ser transferidas a las normativas locales de edificación. 

  18. Survey of pumps for tritium gas

    International Nuclear Information System (INIS)

    Dowell, T.M.

    1983-05-01

    This report considers many different types of pumps for their possible use in pumping tritium gas in the low, intermediate and high vacuum ranges. No one type of pump is suitable for use over the wide range of pumping pressure required in a typical pumping system. The favoured components for such a system are: bellows pump (low vacuum); orbiting scroll pump (intermediate vacuum); magnetically suspended turbomolecular pump (high vacuum); cryopump (high vacuum). Other pumps which should be considered for possible future development are: mound modified vane pump; SRTI wobble pump; roots pump with canned motor. It is proposed that a study be made of a future tritium pumping system in a Canadian tritium facility, e.g. a tritium laboratory

  19. LMR [liquid metal reactor] centrifugal pump coastdowns

    International Nuclear Information System (INIS)

    Dunn, F.E.; Malloy, D.J.

    1987-01-01

    A centrifugal pump model which describes the interrelationships of the pump discharge flowrate, pump speed, shaft torque and dynamic head has been implemented based upon existing models. Specifically, the pump model is based upon the dimensionless-homologous pump theory of Wylie and Streeter. Given data from a representative pump, homologous theory allows one to predict the transient characteristics of similarly sized pumps. This homologous pump model has been implemented into both the one-dimensional SASSYS-1 systems analysis code and the three-dimensional COMMIX-1A code. Comparisons have been made both against other pump models (CRBR) and actual pump coastdown data (EBR-II and FFTF). Agreement with this homologous pump model has been excellent. Additionally, these comparisons indicate the validity of applying the medium size pump data of Wylie and Streeter to a range of typical LMR centrifugal pumps

  20. Work plan, AP-102 mixer pump removal and pump replacement

    International Nuclear Information System (INIS)

    Jimenez, R.F.

    1994-01-01

    The objective of this work plan is to plan the steps and estimate the costs required to remove the failed AP-102 mixer pump, and to plan and estimate the cost of the necessary design and specification work required to order a new, but modified, mixer pump including the pump and pump pit energy absorbing design. The main hardware required for the removal of the mixer is as follows: a flexible receiver and blast shield; a metal container for the pulled mixer pump; and a trailer and strongback to haul and manipulate the container. Additionally: a gamma scanning device will be needed to detect the radioactivity emanating from the mixer as it is pulled from the tank; a water spray system will be required to remove tank waste from the surface of the mixer as it is pulled from the AP-102 tank; and a lifting yoke to lift the mixer from the pump pit (the SY-101 Mixer Lifting Yoke will be used). A ''green house'' will have to be erected over the AP-102 pump pit and an experienced Hoisting and Rigging crew must be assembled and trained in mixer pump removal methods before the actual removal is undertaken

  1. Diode-pumped laser with improved pumping system

    Science.gov (United States)

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  2. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  3. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  4. El back office de capital humano y su impacto en la optimización de procesos y generación de ahorros en costos de servicios en Arca Continental, sucursal Salta, durante el segundo semestre del año 2016

    OpenAIRE

    Giménez Perri, Solana

    2017-01-01

    248 p. il. El tema de la presente investigación fue el back office de capital humano y su impacto en la optimización de procesos y generación de ahorros en costos de servicios en Arca Continental, sucursal Salta, durante el segundo semestre del año 2016. Se trata de un estudio de tipo descriptivo que buscó establecer asociaciones entre tres dimensiones de análisis: back office de capital humano, optimización de procesos y generación de ahorros. En el trabajo de campo se entrevistó a inf...

  5. Diagnóstico y propuesta de plan de mejoramiento en el área financiera para el Sistema de Cooperativas de Ahorro y Crédito del Segmento Uno, reguladas por la Superintendencia de Economía Popular y Solidaria, durante el período 2011- 2014

    OpenAIRE

    Pacheco Guevara, Ximena Patricia

    2016-01-01

    La presente investigación se enfoca en una propuesta de mejora en el área financiera para el sistema de cooperativas de ahorro y crédito del segmento uno, reguladas por la Superintendencia de Economía Popular y Solidaria, durante el período 2011-2014. Bajo este contexto, se revisaron una serie de metodologías aplicadas a nivel internacional, definiendo la creada por el Consejo Mundial de Cooperativas de Ahorro y Crédito WOCCU como la más apropiada, al analizar específicamente cooperativas de ...

  6. Análisis de la eficiencia en las cooperativas de ahorro y crédito en Colombia, mediante la utilización de la técnica de Análisis de Datos Envolvente DEA, periodo 2008-2011

    OpenAIRE

    Moreno Sierra, Vivian Carolina; Rey Huertas, Luis Eduardo

    2015-01-01

    La presente estudio pretende analizar la eficiencia en las cooperativas de ahorro y crédito en Colombia, mediante la utilización de la técnica de análisis de datos envolvente (DEA); el trabajo investigativo es importante analizar al subsector cooperativo de ahorro y crédito para el periodo 2008-2011 debido a que este subsector es el más dinámico del sector cooperativo. La identificación de las cooperativas eficientes requiere de la aplicación de una técnica no paramétrica mediante el análisis...

  7. The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, A. [Universidad Nacional Autonoma de Mexico (Mexico); Islas, J [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Arriola, A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    cantidad representa un porcentaje importante de los gastos totales del hospital (29.367 millones de dolares) es importante determinar posibilidades tecnico - economicas de ahorro de energia termica del hospital. El HGZ N 1 - IMSS Ags. Esta ubicado en un conjunto mas amplio en donde se localizan las unidades del IMSS, tales como, la lavanderia regional, la unidad deportiva, el centro de seguridad social, la unidad de medicina familiar N 1 y el hospital. Sin embargo a partir de las instalaciones electricas y de suministro de vapor y agua caliente del hospital se distribuyen los fluidos electricos y termicos de todo este conjunto. Debido a esta situacion, en este trabajo nos referiremos al consumo global del conjunto del IMSS de Aguascalientes en donde el hospital es el principal consumidor de energia termica. En el presente trabajo calcularemos el potencial tecnico - economico de ahorro de energia termica del conjunto del IMSS a traves de la tecnica termodinamica de punto de pliegue o tecnica pinch.

  8. Pumps in wearable ultrafiltration devices: pumps in wuf devices.

    Science.gov (United States)

    Armignacco, Paolo; Garzotto, Francesco; Bellini, Corrado; Neri, Mauro; Lorenzin, Anna; Sartori, Marco; Ronco, Claudio

    2015-01-01

    The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features. © 2015 S. Karger AG, Basel.

  9. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  10. 46 CFR 119.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge pumps. 119.520 Section 119.520 Shipping COAST... Ballast Systems § 119.520 Bilge pumps. (a) Each vessel must be provided with bilge pumps in accordance... have a portable hand bilge pump that must be: (1) Capable of pumping water, but not necessarily...

  11. 46 CFR 154.1135 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pumps. 154.1135 Section 154.1135 Shipping COAST GUARD... Pumps. (a) Water to the water spray system must be supplied by: (1) A pump that is only for the use of the system; (2) A fire pump; or (3) A pump specially approved by the Commandant (CG-522). (b...

  12. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  13. Marketing estratégico para incrementar la cartera de socios de la Cooperativa de Ahorro y Crédito ?Uniblock? ubicada en la ciudad de Latacunga en el período 2013

    OpenAIRE

    Borja Brazales, Yadira Paola

    2015-01-01

    1. Fundamentos Teóricos.-- 2. Metodología.-- 3.Resultados.-- 4. Propuesta.-- 5. Conclusiones y Recomendaciones El desarrollo del presente trabajo tiene como objetivo diseñar estrategias de marketing para incrementar la cartera de socios de la Cooperativa de Ahorro y Crédito ?Uniblock?. Está investigación consiste en realizar un análisis situacional de la cooperativa, por lo cual primero se elaboró el marco teórico que abarca cada una de las variables objeto de estudio incluidas sus respect...

  14. Descripción y análisis de la aplicación de la teoría general de las organizaciones en el modelo de gestión del Fondo Nacional de Ahorro, FNA

    OpenAIRE

    Isairías Mora, José Edgar; Lozada Angarita, Carlos Eduardo

    2011-01-01

    La tesis que a continuación se presenta corresponde a la Maestría en Dirección y Gerencia de Empresas de la Universidad del Rosario. En ella se revisan y analizan múltiples factores mediante los cuales se determina o no la aplicación de aplicación de la Teoría General de las organizaciones en la gestión del Fondo Nacional de Ahorro, FNA. de la ciudad de Bogotá. En ella se plantean los aspectos que se aplican de cada una de las siguientes teorías organizacionales o administrativas: Administrac...

  15. Levantamiento del proceso de crédito e identificación de eventos de riesgo operativo en la Cooperativa de Ahorro y Crédito OSCUS Ltda.

    OpenAIRE

    Ibarra Licto, Carmen Jacqueline

    2008-01-01

    La Cooperativas de ahorro y crédito, como entidades financieras, actúan, se desarrollan y crecen en busca de beneficios mutuos, servicios financieros con rentabilidad y calidad social, y este negocio genérico, que tiene el dinero como vehículo requiere un adecuado manejo y administración de costos operativos, con el objeto de identificar y eliminar costos superfluos, y reducir al óptimo los necesarios, sin dejar de lado que en la actualidad la calidad, innovación y servicio ...

  16. Sistema de control de gestión de riesgo para la prevención del lavado de activos en la cooperativa de ahorro y crédito Sumak Samy Ltda. de la ciudad de Ambato.

    OpenAIRE

    Carrillo Sarabia, Patricia de las Mercedes

    2017-01-01

    1. Introducción. --2. Planteamiento de la Propuesta de Trabajo. --3. Marco Teórico. --4. Metodología. --5. Resultados. --6. Conclusiones y Recomendaciones. El presente trabajo tiene como objetivo fundamental el desarrollo de un Sistema de control de gestión de riesgo para la prevención del lavado de activos en la Cooperativa de Ahorro y Crédito Sumak Samy Ltda. en la ciudad de Ambato, el cual le permitirá a la cooperativa contar con el Nivel de riesgo de sus socios/clientes y aplicar polít...

  17. Diseño de un modelo de Administración de Riesgo Operativo aplicado al proceso de crédito en la Cooperativa de Ahorro y Crédito "Santa Ana de Nayón"

    OpenAIRE

    Sandoval Zambrano, Emma Patricia

    2016-01-01

    Este trabajo pretende aportar con un modelo de Riesgo Operativo en el Proceso de Crédito, a la Cooperativa de Ahorro y Crédito Santa Ana de Nayón, con el objetivo de disponer de una herramienta que permita mitigar posibles riesgos operativos a los que está expuesta. Intenta también motivar y concientizar a los directivos y a la gerencia de la importancia de la implementación de la Administración Integral de Riesgos, como estrategia institucional y de forma especial la gestión de riesgo operat...

  18. Análisis de la estructura financiera para la toma de decisiones gerenciales en la Junta Administradora del Fondo de Ahorro y Préstamo de la Universidad de Costa Rica

    OpenAIRE

    Rojas González, Catalina

    2012-01-01

    Tesis de maestría -- Universidad de Costa Rica. Posgrado en Administración y Dirección de Empresas. Maestría Profesional en Administración y Dirección de Empresas con énfasis en Finanzas, 2012 El objetivo general del trabajo es elaborar un análisis detallado de los estados financieros de la Junta Administradora del Fondo de Ahorro y Préstamo (JAFAP) de la Universidad de Costa Rica para el período comprendido entre el 31 de diciembre de 2009 y el 31 de diciembre de 2010, con el objetivo de ...

  19. Propuesta de nuevas opciones de inversión y gestión de la cartera de inversiones de la Junta Administradora de Ahorro y Préstamo de la Universidad de Costa Rica

    OpenAIRE

    López Bogantes, Randy Alberto

    2014-01-01

    Tesis de maestría -- Universidad de Costa Rica. Posgrado en Administración y Dirección de Empresas. Maestría Profesional en Administración y Dirección de Empresas con énfasis en Finanzas, 2014 El objetivo general del proyecto es proponer alternativas adicionales de inversión más rentables que permitan a la Junta Administradora de Ahorro y Préstamo de la Universidad de Costa Rica una estructura óptima del portafolio de acuerdo con la normativa interna, al lograr el mejor rendimiento posible...

  20. The use of reflecting paints on building`s roofs for energy saving; Uso de pinturas reflejantes en los techos de las edificaciones para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Jose Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad, Mexico, D. F. (Mexico); Sanchez Soto, Ramon [Facultad de Ingenieria, Departamento de Termoenergia de la UNAM, Mexico, D. F. (Mexico)

    1998-12-31

    This paper shows the effects of the use of reflecting paints in different colors on the buildings roofs and the results in energy saving obtained in a field test carried on in Monterrey, Nuevo Leon State of Mexico using aluminum paint. [Espanol] El presente trabajo muestra los efectos del uso de pinturas reflejantes de diferentes colores en los techos de edificaciones, y los resultados de ahorro de energia electrica obtenidos en una prueba de campo efectuada en Monterrey, Nuevo Leon, Mexico, utilizando pintura de aluminio.