WorldWideScience

Sample records for pumping equipment ahorro

  1. Energy saving in agricultural pumping equipment; Ahorro de energia en equipos de bombeo agricola

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R. Aracely [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1993-12-31

    This paper analyses the current state of the pumping equipment for agricultural irrigation in Mexico. Because of being of the vertical centrifugal turbine type pumps, the most commonly utilized for this service, the study has been focussed into this equipment, obtaining efficiency and consumption scenarios, as well as the potential energy saving existing in this sector. [Espanol] En el presente articulo se analiza el estado actual de los equipos de bombeo para riego agricola en Mexico, al ser las bombas centrifugas verticales tipo turbina, las mas comunmente utilizadas para este servicio, el estudio ha sido enfocado a estos equipos, obteniendose los escenarios de eficiencias y consumos, asi como, el potencial de ahorro energetico existente en este sector.

  2. Proposal for energy saving in air conditioning equipment; Propuesta para ahorro energetico en acondicionadores de aire

    Energy Technology Data Exchange (ETDEWEB)

    Solis Recendez, Daniel H [Division de Ingenieria Electrica, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-10-15

    In the last decades, the air conditioning systems have become a crucial part in the search from comfort in extreme climates. Nevertheless, they have also become one of the greatest energy consumers. In this article it is proposed that the final conditions that the air conditioning equipment looks for not to be fixed, but variable in respect to a certain comfort zone. This zone is a variation of the used one in the bio-climatic chart of Olgyay that considers the rapidity whereupon the reached conditions tend to leave the comfort zone. It is analyzed how to choose the point on the zone that costs less energy in arriving to it. [Spanish] En las ultimas decadas, los sistemas de aire acondicionado se han vuelto una parte crucial en la busqueda de confort en climas extremosos. Sin embargo, tambien se han vuelto de los mayores consumidores de energia. En este articulo se propone que las condiciones finales que busquen lograr los acondicionadores no sean fijas, si no variables respecto a una determinada zona de confort. Dicha zona es una variacion de la utilizada en la carta bioclimatica de Olgyay, que considera la rapidez con que las condiciones alcanzadas tienden a abandonar la zona de confort. Se discute como elegir el punto sobre la zona que cueste menos energia en llegara el.

  3. Energy saving in the pumping of drinking water, Municipality of San Felipe, Guanajuato; Ahorro de energia electrica en bombeo de agua potable, en el municipio de San Felipe, Gto.

    Energy Technology Data Exchange (ETDEWEB)

    Gamiz Sanchez, Lorenzo [Applied Technology Center de Mexico, S.A. de C.V. (Mexico)

    2006-01-15

    This paper shows the results attained in energy saving through a project of potable water pumping, which took an investment of $433,043.00 and an internal rate of return of 126%. This project puts into evidence that it is possible to reduce between 15 and 30% of the total invoicing for energy consumption in potable water pumping if an equipment of poor efficiency is replaced by another of high efficiency. The project was requested by the Guanajuato's State Water Comision and the Municipal Bureau of Sewage and Potable Water, with the double intention of reducing the energy consumption along with the corresponding invoicing and incrementing the output of the wells in order to improve the potable water supply. In the site two high efficiency submersible motor-pumps were installed previously to the energy diagnosis that triggered profitable operation results and a convenient invoicing. [Spanish] Se documentan los resultados obtenidos en un proyecto de ahorro de energia en el bombeo de agua potable realizado con una inversion de $433,043.00 y con una tasa interna de retorno de 126%. Este proyecto pone en evidencia que es posible reducir entre el 15 y 30% de la facturacion total por consumo de energia electrica en el bombeo de agua potable si se sustituye un equipo poco eficiente por otro de alta eficiencia. El proyecto fue solicitado por la Comision Estatal del Agua de Guanajuato y la Junta Municipal de Agua Potable y Alcantarillado del municipio, con un doble proposito, reducir el consumo de energia junto con la facturacion correspondiente e incrementar la capacidad de produccion de los pozos con la intencion de mejorar el abasto de agua potable. En el lugar se instalaron dos motobombas sumergibles de alta eficiencia previo diagnostico energetico que desencadenaron rentables resultados operativos y de facturacion.

  4. Energy saving in hotels by means of heat pumps application; Ahorro de energia en hoteles mediante la aplicacion de bombas de calor

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes R, Hernando; Ambriz G, Juan Jose [Universidad Autonoma Metropolitana, Unidad Iztapalapa (Mexico)

    2005-07-15

    The thermal energy is presented as an alternate saving technology for utilities by means of the acute implementation of heat pumps. The objective is to demonstrate the technical and economical feasibility of the application of commercial heat pumps to installations where the handling of opposite temperatures for the conditioning of a space and/or of a fluid is required. In this article it is described the functioning of a heat pump, its different operation principles or types as well as the large diversity of applications they can have in industry, utilities and residential buildings. As an application example the substitution of an electric boiler by a heat pump is presented in a hotel installation and its differences in performance regarding the environmental conditioning of a nearby area and the heating of swimming pool water are analyzed. [Spanish] Se presenta la energia termica como una tecnologia de ahorro alterna para empresas de servicios valiendose de la implementacion agudizada de bombas de calor. El objetivo es demostrar la factibilidad tecnica y economica de la aplicacion de bombas de calor comerciales a instalaciones donde se requiere la manipulacion de temperaturas opuestas para el acondicionamiento de un espacio y/o un fluido. Se describe el funcionamiento de una bomba de calor, sus diferentes principios de operacion o tipos, asi como la gran diversidad de aplicaciones que pueden tener en la industria, empresas de servicios y edificios residenciales. Como ejemplo de aplicacion se presenta la sustitucion de una caldera electrica por una bomba de calor en una instalacion hotelera y sus diferencias de rendimiento en el calentamiento de agua de alberca y el acondicionamiento ambiental de un area cercana.

  5. Evaluation of energy saving in pilot projects of window type air conditioning equipment in the domestic sector; Evaluacion del ahorro de energia en proyectos pilotos en equipos de aire acondicionado tipo ventana en el sector domestico

    Energy Technology Data Exchange (ETDEWEB)

    Duran Ramirez, Ricardo [Comision Nacional para el Ahorro de Energia, Mexico, D.F. (Mexico)

    2001-07-01

    The present work shows the energy saving when replacing low efficiency window type air conditioning equipment, for higher efficiency equipment, as well as the necessary parameters to identify the results obtained by the pilot projects of substitution of conventional equipment for other more efficient in the domestic sector. [Spanish] El presente trabajo muestra los ahorros de energia al sustituir equipos de aire acondicionado tipo ventana de baja eficiencia, por equipos de mayor eficiencia, asi como los parametros necesarios para identificar los resultados obtenidos, por los proyectos pilotos de sustitucion de equipos convencionales por otros mas eficientes en el sector domestico.

  6. Dewatering gas wells with pneumatic pumping equipment

    Energy Technology Data Exchange (ETDEWEB)

    Nickell, R.L.

    1973-01-01

    El Paso Natural Gas Co. has been operating pumping units on gas wells since 1964. At present, the company operates some 69 pumping units in the E. Panhandle field in Texas and the S. Erick field in Oklahoma. Of these 6 are pneumatic units and the remainder is conventional beam type units powered by gas-fueled engines or electric motors. A graphical representation of the data obtained from the El Paso wells in which various lift facilities are installed is included. These data show initial cost, maintenance cost, and lift cost per barrel of (1) gas engine beam unit; (2) electric beam unit; (3) pneumatic unit; (4) gas lift; and (5) intermitter. While not a panacea for all dewatering ills, pneumatic pumping represents an economical tool which may be applied to a wide range of conditions.

  7. Heat pumps in industry: Pt. 1; Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. (Padua Univ. (Italy). Ist. di Ingegneria Gestionale)

    1994-11-01

    Industrial heat pumps are reviewed, classifying them according to the way by which the working fluid is taken from the lower to the higher pressure: mechanical or thermal. Each group is further subdivided in closed and open cycle. The most recent technological developments are considered for each classification. (author)

  8. Energy saving by means of air conditioning equipment replacement and the household application of thermal insulation; Ahorro de energia electrica por reemplazo de equipos de aire acondicionado y aplicacion de aislamiento termico en viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de la Energia (Mexico)

    2005-07-15

    An extension study of the Financing Program for Energy Saving looked for the evaluation of the electric energy saving potential obtained by the replacement of air conditioning equipment and the application of thermal insulation in 30 houses of two Mexican cities with warmth climate. In a joint effort with Comision Federal de Electricidad the consumption files of the users were analyzed and field measurements of electric demand and of refrigeration were made. As a following step the change of the refrigeration necessities derived from the application of thermal insulation were evaluated as well as the energy efficiency improvement obtained by the substitution of the air conditioning equipment and the favorable results obtained by the implementation of both measures - thermal insulation and change of air conditioning equipment in a joint form. This way, as a conclusion, the optimum sequence of application of these measures is revealed. [Spanish] Un estudio extension del Programa de Financiamiento para el Ahorro de Energia Electrica busco evaluar el potencial de ahorro de energia electrica alcanzado por el reemplazo de equipos de aire acondicionado y la aplicacion de aislamiento termico en 30 viviendas de dos ciudades mexicanas con clima calido. En un esfuerzo conjunto con la Comision Federal de Electricidad se analizaron los historiales de consumo de los usuarios y se efectuaron las mediciones de campo de demanda electrica y de refrigeracion. Como paso siguiente se valoro el cambio en las necesidades de refrigeracion derivado de la aplicacion de aislamiento termico al igual que la mejora en eficiencia energetica obtenida por la sustitucion de aire acondicionado y se identificaron los resultados favorecedores arrojados por la implementacion de ambas medidas -aislamiento termico y cambio de equipo de aire acondicionado- en forma conjunta. De esta manera, como conclusion, se devela la mas optima secuencia de aplicacion de estas medidas.

  9. Energy saving in the auxiliaries consumption for circulation water pumps optimizing the thermal regime; Ahorro en el consumo de auxiliares por bombas de agua de circulacion optimando el regimen termico

    Energy Technology Data Exchange (ETDEWEB)

    Orozco Martinez, Roni [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    A methodology is proposed that should be followed in any thermal electric power plant to determine the load value at which a unit requires a second circulation water pump without affecting the thermal regime and avoiding an excessive auxiliaries consumption in partial loads. In applying this method the power plant would have an energy saving equivalent to the auxiliaries consumption during an hour, when the unit as operating at full load. [Espanol] Se propone una metodologia que debe seguirse en cualquier central termoelectrica para determinar el valor de la carga en la cual una unidad requiere de la segunda bomba de agua de circulacion sin afectar el regimen termico y evitadose un excesivo consumo de auxiliares en cargas parciales. Al aplicar este metodo la central tendria un ahorro de energia equivalente al consumo de auxiliares durante una hora cuando la unidad esta generando su maxima carga.

  10. Failure Mode and Effect Analysis of Subsea Multiphase Pump Equipment

    Directory of Open Access Journals (Sweden)

    Oluwatoyin Shobowale Kafayat

    2014-07-01

    Full Text Available Finding oil and gas reserves in deep/harsh environment with challenging reservoir and field conditions, subsea multiphase pumping benefits has found its way to provide solutions to these issues. Challenges such as failure issues that are still surging the industry and with the current practice of information hiding, this issues becomes even more difficult to tackle. Although, there are some joint industry projects which are only accessible to its members, still there is a need to have a clear understanding of these equipment groups so as to know which issues to focus attention on. A failure mode and effect analysis (FMEA is a potential first aid in understanding this equipment groups. A survey questionnaire/interview was conducted with the oil and gas operating company and equipment manufacturer based on the literature review. The results indicates that these equipment’s group are similar with its onshore counterpart, but the difference is the robustness built into the equipment internal subsystems for subsea applications. The results from the manufacturer perspectives indicates that Helico-axial multiphase pump have a mean time to failure of more than 10 years, twin-screw and electrical submersible pumps are still struggling with a mean time to failure of less than 5 years.

  11. Heat pumping using the thermal earth gradient to produce air conditioned and hot water with savings of up to 70%; Bombeo de calor utilizando el gradiente termico de la tierra para producir aire acondicionado y agua caliente con ahorros de hasta un 70%

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Ramirez, Alejandro [Novaenergia de Mexico S.A. de C.V. (Mexico)

    2003-07-01

    The pumping of heat using the Earth heat as partial energy source bases its principle on which the energy of the ground is constant and the energy efficiency to produce air conditioning and hot water simultaneously is important, obtaining savings up to 70%, comparing itself with the traditional equipment and what these operate of separated way to produce each one of them the cold air and the hot water. The use of this technology presents an opportunity to reduce the energy costs of and the demand of the company. [Spanish] El bombeo de calor utilizando el calor de la tierra como fuente parcial de energia basa su principio en que la energia del suelo es constante y el rendimiento energetico para producir simultaneamente aire acondicionado y agua caliente es importante, obteniendose ahorros hasta de un 70%, comparandose con los equipos tradicionales y que estos operan de manera separada para producir cada uno de ellos el aire frio y el agua caliente. El uso de esta tecnologia presenta una oportunidad para reducir los costos de energia y demanda de la empresa.

  12. Energy saving: optimal use of air conditioning equipment by means of the solar control; Ahorro de energia: uso optimo de los acondicionadores de aire mediante el control solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico (Mexico)

    2001-09-01

    In this article the evaluation of the solar heat gains through the transparent parts of a building (houses of social interest) is presented; with the purpose of determining the heat gains through windows during summer time and under the following conditions: without solar protection, with the use of eaves, solar breakers and, finally, with the use of both elements. With the determined percentage of the diminution of heat gains, the considered potential of energy saving in air conditioning was obtained that would be available if the houses were constructed with solar control. [Spanish] En este articulo se presenta la evaluacion de las ganancias de calor solar a traves de las partes transparentes de un edificio (viviendas de interes social); con el objeto de determinar las ganancias de calor a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin proteccion solar, con el empleo de aleros, con quiebrasoles y, finalmente, con el empleo de ambos elementos. Con el porcentaje determinado de la disminucion de ganancias de calor, se obtuvo el potencial estimado de ahorro de energia en aire acondicionado que se tendria si las viviendas se construyen con control solar.

  13. Program of actions for energy conservation in the equipment for the urban public transportation; Programa de acciones para el ahorro de la energia en los equipos de transporte publico urbanos

    Energy Technology Data Exchange (ETDEWEB)

    Sanhez Arellano, L.I. [Facultad de Ingenieria, Universidad Autonoma del Estado de Mexico, Toluca (Mexico)

    1995-12-31

    The Facultad de Ingenieria of the Universidad Autonoma del Estado de Mexico (UAEM), in its postgraduate program in Transport Engineering carries out research projects aimed at the appropriate operation of the urban public transportation, in the definition of the transportation networks and their exploitation as well as in the energy conservation and efficient use of the energy for its operation. This paper embodies the lines of interest of this program. The proper operation characteristics and the energy consumption of the different types of vehicles used in urban public transportation mainly depend on the application they have been designed for. Nevertheless, an important point is to know, in the most concrete and specific form, the nature and other possible utilization options of the different urban transportation systems, as well as its energy impact and the possibility of a well oriented energy conservation. The purpose of this paper is to present in a concrete manner the different types of vehicles used in the urban public transportation, making an energy comparison, besides setting forth a program of actions tending to the energy saving for the vehicles that nowadays operate in the main cities of our country. The main actions are pointed out and the basic characteristics for their initiation, which can be summarized in three large groups: -action in the proper enterprises and with existing vehicular park. -actions over the management and exploitation of the transportation systems. -action for the utilization of new equipment and more efficient vehicles. A detailed explanation of each one of these actions and their impact on the energy consumption are the final purpose of this study. [Espanol] La Facultad de Ingenieria de la Universidad Autonoma del Estado de Mexico (UAEM), dentro de su programa de Postrado en Ingenieria del Transporte realiza proyectos de investigacion tendientes en la buena operacion de los transportes publicos urbanos, en la definicion de

  14. 78 FR 11996 - Energy Efficiency Program for Commercial and Industrial Equipment: Commercial and Industrial Pumps

    Science.gov (United States)

    2013-02-21

    ... Equipment: Commercial and Industrial Pumps AGENCY: Office of Energy Efficiency and Renewable Energy... conservation standards for commercial and industrial pumps published on February 1, 2013, is extended to May 2... Document relating to commercial and industrial pumps is extended to May 2, 2013. ADDRESSES: Any...

  15. Development and exploitation features of methane-coal wells using downhole pumping equipment

    Directory of Open Access Journals (Sweden)

    Kurganova Elena

    2016-01-01

    Full Text Available In this article extraction of methane from coal beds is presented. The article presents results of the study of downhole pumping equipment used in the exploitation of coal bed methane wells. The features of various types of equipment such as piston sucker-rod pumping units, electrical centrifugal pumping units and sucker-rod screw pumping units have been considered. The results show benefits of sucker-rod screw pumping units because of their versatility and resistance to higher content of mechanical impurities.

  16. Proceedings of the 24. National seminar on the rational use of energy and exposition of equipment and services and 7. Binational seminar on energy saving [Selected Papers]; 24. Seminario nacional sobre el uso racional de energia y exposicion de equipos y servicios y 7. Seminario binacional de ahorro de energia. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This document contains the technical briefings of the 24. National Seminar on the rational use of energy, and exhibition of the equipment and services and the 7. Binational seminar on energy saving, organized by the Asociacion de Profesionistas y Tecnicos en Aplicacion Energetica (ATPAE), in Ciudad Juarez, Chihuahua, Mexico, from November 9 to 11, 2005. This seminar dealt with subjects such as: electrical energy saving, energy distribution, solar energy, energy saving in compressed air, biomass, administration and control of the demand of the electrical energy, bioclimatic architecture, use of the compressed natural gas, renewable energy, co-generation, qualification and consultancy for the intelligent use of the energy in PyMES. [Spanish] Este documento contiene la memoria tecnica del 24 Seminario Nacional sobre el uso racional de energia, y exposicion de los equipos y servicios y el 7 Seminario binacional de ahorro de energia, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Ciudad Juarez, Chihuahua, Mexico, del 9 al 11 de noviembre del 2005. Este seminario trato temas tales como: ahorro de energia electrica, distribucion de la energia, energia solar, ahorro de energia en aire comprimido, biomasa, administracion y control de la demanda de la energia electrica, arquitectura bioclimatica, uso del gas natural comprimido, energia renovable, cogeneracion, capacitacion y consultoria para el uso inteligente de la energia en las Pymes.

  17. THE CALCULATION OF THE PERFORMANCE PARAMETERS OF PUMPING EQUIPMENT AND PIPING NETWORK OF WATER SUPPLY AND RECLAMATION PUMPING STATIONS

    Directory of Open Access Journals (Sweden)

    Rahnyanskaya O. I.

    2015-06-01

    Full Text Available The calculation of pumping equipment and piping network parameters is presented. The method of cutting impeller pump diameter for optimal performance of pump unit with piping system on efficiency value is shown. The case of operating the distribution network and pumping station with three pump units D1250-25 is considered. Procedure of construction of loss-of-head curves in pipes, determination of the actual operating parameters of a single pump unit, selection of pump impeller diameter for essentials is indicated. Four points for graphing such curves are presented. According to the first point the whole network is divided into sections with suction, pressure main pipelines and pipelines with changing water flow compared with the previous ones. The second point involves definition of the electrical resistivity of each site. The resistance of network analyzer is determined in the third point, the loss-of -head of the whole network is determined in the fourth point. The article presents the scheme of pumping station with three pump units connected in parallel and a distribution network (Figure1, loss-of-head curves in pipes regardless the number of working pumps (Figure 2, the order of constructing three loss-of-head curves with operating one, two and three pumps with normal and cut pump impeller diameter (Figure 3 , the order of determination of the actual parameters of pump work characteristics according to combined characteristics of normal and cut pump impeller diameter ( Figure 4 In conclusion, it is stated that the question of proper definition of actual parameters of pumps and the support of these parameters in optimal mode remains open due to the lack of proper methods of constructing loss-of-head curves pipeline. Every similar calculation is preliminary and should be carried out in field conditions

  18. Technology assessment of geothermal pumping equipment. final report, July 1978

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, K.E.; Malgieri, A.J.

    1978-09-01

    Twenty-eight separate interviews were conducted with DOE personnel, DOE contractors doing geothermal research, persons associated with geothermal installations, companies engaged in the drilling and completion of geothermal well, and pump manufactures. The reports of these interviews are presented and summarized and conclusions are drawn.

  19. Investigation on the influence of jetting equipment on the characteristics of centrifugal pump

    Directory of Open Access Journals (Sweden)

    Qiaorui Si

    2016-08-01

    Full Text Available To reduce radial noises from the motor of centrifugal pumps, this study designed a water cooling system called jetting equipment to replace traditional fan cooling systems in pump motors. By measuring radiated noises, head, efficiency, and cavitation performance, the research compared the differences among experimental results of the original pump unit, the one with a normal design jetting pipe and another one with a larger jetting pipe. Results show that the radiated sound pressure level of the model pump was significantly reduced by 8.3 dB after integrating the jetting pipe. With a normal jetting pipe, no significant changes were observed in the head, efficiency, and shaft power curves, and cavitation performance improved under small flow rate. However, the performance with the larger jetting pipe worsened, except the hump phenomenon of the model pump under a small flow rate was enhanced. Computational fluid dynamics method was used to calculate the internal flow of three model pumps in order to investigate the jetting flow effect. A comparison among the flow fields at the inlet of the three types of pumps indicated that high-pressure water injection can effectively control inlet recirculation and improve velocity distribution in the inlet flow field with decreased recirculation vortex strength and recirculation onset critical flow rate.

  20. Sodium--NaK engineering handbook. Volume IV. Sodium pumps, valves, piping, and auxiliary equipment

    Energy Technology Data Exchange (ETDEWEB)

    Foust, O J [ed.

    1978-01-01

    The handbook is useful for designers in the Liquid Metals Fast Breeder Reactor (LMFBR) program and by the engineering and scientific community performing investigation and experimentation requiring high-temperature Na and NaK technology. Data are presented for pumps, bearings and seals, valves, vessels and piping, and auxiliary equipment including vapor traps, freeze plugs, fuel-channel flow regulators, antivortexing devices, and miscellaneous mechanical elements. Reactor materials are also discussed. (FS)

  1. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Science.gov (United States)

    Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner Equipment that are effective as of September 15, 2015. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/index.cfm?c=airsrc_heat.pr_crit_as_heat_pumps Listed products have been submitted to EPA by ENERGY STAR partners that do not participate in the AHRI certification program. EPA will continue to update this list with products that are certified by EPA-recognized certification bodies other than AHRI. The majority of ENERGY STAR products, certified by AHRI, can be found on the CEE/AHRI Verified Directory at http://www.ceedirectory.org/

  2. High-efficiency gas heat pump air-conditioner equipped with absorption refrigerator

    Science.gov (United States)

    Imai, Yosuke; Ohashi, Toshinori; Okamoto, Hiroaki; Hihara, Eiji; Kawakami, Ryuichiro

    On conventional gas heat pump(GHP), waste heat from gas engine that uses as driving source is emitted into outside. So from the standpoint of efficient use of waste heat, it is assumed that waste heat from gas engine is used as driving source of absorption chiller, and high temperature condensate refrigerant in GHP is subcooled to middle temperature by cold source from absorption cycle, and as a result, GHP makes more efficiency. However, in equipping GHP with absorption cycle, downsizing and high-efficiency of absorption cycle is required. In this study, air-cooled subcooled adiabatic absorber is focused and physical phenomenon in it is analyzed, and finally one perception of the optimized designing is shown.

  3. Optimal Duration of Submersible Pump Equipped Deep Water Borehole Project in Ikwuano, Nigeria

    Directory of Open Access Journals (Sweden)

    Nwankwojike, B. Nduka

    2014-12-01

    Full Text Available Optimal duration for constructing a submersible pump equipped deep water borehole in Ikwuano and optimal durations of distinct jobs in this project were determined to aid effective planning and implementation of borehole projects in this area. The investigation was conducted and analyzed using network modeling procedure. Results revealed 13days as the optimal duration of the borehole project when construction of overhead water distribution tank stantion constitutes part of the contract and 12days when the overhead structure is not involved. The optimal duration in hours for the distinct jobs involved in this borehole construction include 25.92 for site preparation/mobilization of geophysical survey team, 36 for geophysical analysis/selection of the best water yielding point in the site, 72 for mobilizing labour and materials to the selected site, 168 for constructing overhead water distribution tank stantion, 3.12 for placement of overhead tank(s on its stantion/installation of its water conveying pipes/accessories, 4.56 for casing/gravel packing/flushing materials preparation, 19.44 for well drilling, 1.92 for casing, 1.92 for gravel packing, 1.2 for flushing, 25.92 for water collection/analysis, 1.2 for water treatment, 13.44 for pumping test, 25.92 for platforming, 77.04 for pump installation/integration of water conveying systems, 4.8 for test running and 0.96 for training end users/project commission. Thus, a guide for effective planning to ensure adequate and timely implementation of deep borehole water supply projects in Ikwuano is set.

  4. The Operational Features of Pumping Stations Equiped with Parallel-Connected Centrifugal Pumps for Land-Reclamation

    Directory of Open Access Journals (Sweden)

    Khalid S. Al-Rababa

    2005-01-01

    Full Text Available The required water supply of a pump could be provided by means of different combinations of pressure piping and pumping units at different operational costs. The basic indices describing the operational modes for the individual and group pumping units, including the values of the efficiency, are computed. The adequacy of the calculational results that based on the developed mathematical models is confirmed by the full-scale experimental researches. Based on the presented principles of the load distribution between parallel working pumping units, 5 % of consumed electric power may be saved.

  5. Electric power saving in the drinkable water, sewage and sanitation system, La Piedad; Ahorro de energia electrica en el sistema de agua potable, alcantarillado y saneamiento de La Piedad

    Energy Technology Data Exchange (ETDEWEB)

    Sistema de Agua Potable, Alcantarillado y Saneamiento de la Piedad (Mexico). E-mail: sapaslapiedad@prodigy.net.mx

    2006-04-15

    In Michoacan, Mexico, a project who seeks to benefice the Municipal public resources was crated in 1994. It would be achieved trough the electric power saving in the public lighting system, and drinkable water pumping and black water, since those activities required the budget biggest part. The program could be developed recently and the saving was significant. In addition the electromechanical efficiency increased in the equipment installation. This work is an example for other States to do something similar that can improve their conditions. [Spanish] En el estado de Michoacan, Mexico se creo un proyecto en el ano de 1994, el cual buscaba beneficiar los recursos publicos municipales, a traves del ahorro de la energia electrica en los sistemas de alumbrado publico y bombeo de agua potable y aguas negras, ya que estas actividades son las que requieren la mayor parte del presupuesto. El programa pudo llevarse a cabo en anos recientes y el ahorro fue significativo, ademas de que aumento la eficiencia electromecanica en los equipos que se instalaron, y esta obra ha servido de ejemplo a otros estados para que realicen algo similar que pueda mejorar su situacion.

  6. Determinantes del ahorro interno: El caso argentino

    OpenAIRE

    Ricardo López-Murphy; Fernando Navajas; Santiago Urbiztondo; Cynthia Moskovitz

    1998-01-01

    Se ha señalado en numerosos debates recientes que el proceso de crecimiento y estabilización macroeconómica iniciado en Argentina a comienzos de los años noventa, vino acompañado por una insuficiencia del ahorro doméstico para financiar el fuerte crecimiento de las inversiones. La contrapartida fue un importante déficit en cuenta corriente y un incremento en el ingreso de capitales hasta 1994. Desde entonces la economía argentina debió ajustarse a las condiciones originadas luego de la devalu...

  7. ENERGY STAR Certified Non-AHRI Central Air Conditioner Equipment and Air Source Heat Pump

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 5.0 ENERGY STAR Program Requirements for Air Source Heat Pump and Central Air Conditioner...

  8. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  9. Evaluation of rotor axial vibrations in a turbo pump unit equipped with an automatic unloading machine

    Science.gov (United States)

    Martsynkovskyy, V. A.; Deineka, A.; Kovalenko, V.

    2017-08-01

    The article presents forced axial vibrations of the rotor with an automatic unloading machine in an oxidizer pump. A feature of the design is the use in the autoloading system of slotted throttles with mutually inverse throttling. Their conductivity is determined by a numerical experiment in the ANSYS CFX software package.

  10. Evaluating Performance of Water Hammer Control Equipment using Hytran Software in Hasanlu Dam Pumping Station

    Directory of Open Access Journals (Sweden)

    Parisa Nazari

    2016-09-01

    Full Text Available Unsteady flows start from a steady state and end the other steady state condition. In water lines unsteady flows occur mainly due to the closure of valves, sudden pumps stops or sudden pumps starts. To prevent these losses, the major ways which can be used are pressure valves, air tanks and surge tanks. All various methods of controlling water hammer pursue a common goal, and that is to balance pressure from water hammer to adjust the pressure in an acceptable range in the network. In this paper, unsteady hydraulic flow control methods include protective measures such as the use of check valve and installation of air valves, air chambers and surge tanks are investigated and compared. And so that the1400 mm existing pipe line of Hasanlu dam pump station, can be simulated using Hytran software, and then minimum and maximum pressure due to the different choking in the throat connecting the main route was evaluated. The results presented that the use of check valve with built-in soft starter in the present case study reduces the positive and negative pressure caused by the water hammer phenomenon as possible value.

  11. Experience on photovoltaic pumping solar systems and mathematical simulation of solar pumping with standard equipment; Experiencia en sistemas de bombeo solar y simulacion matematica de bombeos solares con equipos estandar

    Energy Technology Data Exchange (ETDEWEB)

    Horno, E.; Perpinan, O.; Hungria, J.; Rai, I.; Eyras, R.

    2004-07-01

    The equipment used in photovoltaic pumping solar systems have evolved from initial configurations with specific equipment for solar use to nowadays state-of-the-art systems where easily available standard equipment is used. ISOFOTON's experience on design, installation and operation of large solar pumping projects, carried out over the last eight years in several countries world wide, have proved the higher reliability of this configuration and points out some possible improvements by the use of simple accessories. Researching a sizing method standardization, it also has been developed a mathematical model that simulates the behaviour of solar pumping, having been obtained a good mismatch among sizing expected values and real data on in-site experiences, sited in places with various environmental conditions. (Author)

  12. Standardization for electric energy saving; Normalizacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Reyes Diaz, Arturo [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    This work describes shortly the current legislation on the standardization; as well as the participation of the entities Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) and Programa de Ahorro de Energia (PAESE) in the consulting committees, for the elaboration of the Mexican official standards focussed to electric power saving. [Espanol] El presente trabajo, describe brevemente la legislacion actual sobre la normalizacion; asi como la participacion de las entidades Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) y Programa de ahorro de Energia (PAESE) en los comites consultivos, para la elaboracion de normas oficiales mexicanas enfocadas al ahorro de energia electrica.

  13. Factores determinantes del ahorro interno en América Latina

    OpenAIRE

    Carlos Añez; Angel Urbina; Lionar Ojeda

    2002-01-01

    El siguiente artículo aborda el problema del financiamiento de la inversión para un país en desarrollo, específicamente de la América Latina, tratando de revisar la literatura disponible para llegar a conclusiones sobre cómo los determinantes del ahorro en todas sus versiones -ahorro externo, ahorro privado y ahorro público- ejercen influencia sobre el proceso de crecimiento. Aun cuando la dirección causal exacta entre ahorro y crecimiento no ha sido establecida, el desarrollo de ...

  14. Economic Viability of Pumped-Storage Power Plants Equipped with Ternary Units and Considering Hydraulic Short-Circuit Operation

    Science.gov (United States)

    Chazarra, Manuel; Pérez-Díaz, Juan I.; García-González, Javier

    2017-04-01

    This paper analyses the economic viability of pumped-storage hydropower plants equipped with ternary units and considering hydraulic short-circuit operation. The analysed plant is assumed to participate in the day-ahead energy market and in the secondary regulation service of the Spanish power system. A deterministic day-ahead energy and reserve scheduling model is used to estimate the maximum theoretical income of the plant assuming perfect information of the next day prices and the residual demand curves of the secondary regulation reserve market. Results show that the pay-back periods with and without the hydraulic short-circuit operation are significantly lower than their expected lifetime and that the pay-back periods can be reduced with the inclusion of the hydraulic short-circuit operation.

  15. Wear analysis of diesel-engine fuel-injection pumps from military ground equipment fueled with Jet A-1. Interim report Jan-May 91

    Energy Technology Data Exchange (ETDEWEB)

    Lacey, P.I.

    1991-05-01

    The U.S. Department of Defense has adopted the single fuel for the battlefield concept. During Operation Desert Shield/Storm, Jet A-1 replaced diesel in many applications. A simultaneous increase in fuel injection pump failures was observed during that operation. Prior to its introduction, a number of studies had indicated that JP-8 is compatible with the current fleet of ground equipment. This report forms part of an ongoing study to define the fuel lubricity requirements of ground equipment. The report also details the wear and failure mechanisms observed from used pumps. The results indicate that, although Jet A-1 does increase wear, many other failure mechanisms are also prevalent.

  16. Results in energy saving obtained with the application of speed variator in fossil power stations; Resultados de ahorro de energia obtenidos con la aplicacion de variadores de velocidad en centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Merlos Rueda, Rosa Maria [Programa de Ahorro de Energia del Sector Electrico (PAESE), Mexico, D. F. (Mexico)

    1999-07-01

    The project of installation of speed variator in fossil power stations (CT's) of Comision Federal de Electricidad (CFE), as an energy saving measure, is a pilot project that began with the support of the Subdivision de Generacion, and promoted by the Energy Saving Program of the Electric Sector (PAESE), with the putting in operation of an equipment in the condensate pump of the Punta Prieta II C. T. U3. The energy saving observed was substantial, fluctuating between the 19.4% at high loads (at 90% load) and the 71.1% at low loads (at 40% load) of the generating unit. With these results, it was decided to extend the scope of the project with the installation of 6 more equipment for equal number of fossil power stations, located in 4 of the 5 Regions of Generation. The fossil power stations, selected for this stage of the project were: C. T. Felipe Carrillo Puerto U1, C.T. Lerma U4, C.T. Salamanca U1, C.T. Monterrey U6, C.T. Francisco Villa U3 and the C.T. Punta Prieta II-U1. The equipment was in operation during the first quarter of 1998, and the first results indicate an energy savings average per equipment, between 39% and 52%. The recovery of the investment fluctuates between the 48.4% and the 87.6% in less than two years of operation, with which a maximum period of recovery of 3 years is expected. The estimated potential of energy saving, considering the application of these devices in condensate pumps, feedwater pumps (where no speed variator is installed) forced draft fans, induced draft fans and gas recirculation fans, as well as circulation water pumps, of the existing Generating Power stations, ascends to an annual total of 830,000, which represents an approximate 9.4% of the National consumption of self services. [Spanish] El proyecto de instalacion de variadores de velocidad en Centrales Termoelectricas (CT's) de la Comision Federal de Electricidad (CFE), como medida de ahorro de energia, es un proyecto piloto que se inicio con el apoyo de la

  17. Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump and Heat Recovery Equipment in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard; Nigusse, Bereket; Domitrovic, Ron

    2013-09-30

    The University of Central Florida/Florida Solar Energy Center, in cooperation with the Electric Power Research Institute and several variable-refrigerant-flow heat pump (VRF HP) manufacturers, provided a detailed computer model for a VRF HP system in the United States Department of Energy's (U.S. DOE) EnergyPlus? building energy simulation tool. Detailed laboratory testing and field demonstrations were performed to measure equipment performance and compare this performance to both the manufacturer's data and that predicted by the use of this new model through computer simulation. The project goal was to investigate the complex interactions of VRF HP systems from an HVAC system perspective, and explore the operational characteristics of this HVAC system type within a laboratory and real world building environment. Detailed laboratory testing of this advanced HVAC system provided invaluable performance information which does not currently exist in the form required for proper analysis and modeling. This information will also be useful for developing and/or supporting test standards for VRF HP systems. Field testing VRF HP systems also provided performance and operational information pertaining to installation, system configuration, and operational controls. Information collected from both laboratory and field tests were then used to create and validate the VRF HP system computer model which, in turn, provides architects, engineers, and building owners the confidence necessary to accurately and reliably perform building energy simulations. This new VRF HP model is available in the current public release version of DOE?s EnergyPlus software and can be used to investigate building energy use in both new and existing building stock. The general laboratory testing did not use the AHRI Standard 1230 test procedure and instead used an approach designed to measure the field installed full-load operating performance. This projects test methodology used the air

  18. LDV measurements of the velocity field on the inlet section of a pumped storage equipped with a symmetrical suction elbow for variable discharge values

    Science.gov (United States)

    ǎghici, I., Dr; Muntean, S.; Bosioc, A. I.; Anton, L. E.

    2014-03-01

    The storage pumps are equipped with various types of inlet casings. The flow nonuniformity is generated by the suction elbows being ingested by the impeller leading to unsteady phenomena and worse cavitational behaviour. A symmetrical suction elbow model corresponding to the double flux storage pump was manufactured and installed on the test rig in order to assess the flow field at the pump inlet. The experimental investigations are performed for 9 discharge values from 0.5 to 1.3 of nominal discharge. LDV measurements are performed on the annular section of the pump inlet in order to quantify the flow non-uniformity generated by the symmetrical suction elbow. Both axial and circumferential velocity components are simultaneously measured on the half plane (180°) of the annular inlet section along to 19 survey axis with 62 points on each. The flow field on the next half plane is determined tacking into account the symmetry. As a result, the flow map on the pump inlet annular section is reconstructed revealing a significant variation of the circumferential velocity component. The absolute flow angle is computed showing a significant variation of ±38°.

  19. Development of the matching equipment of the truck-mounted pumping unit%车载抽油装置配套设备的研制

    Institute of Scientific and Technical Information of China (English)

    槐庆林; 王江; 李斌; 李建友; 付玉东

    2001-01-01

    The paper briefly generalizes the developing back ground of the truck-mounted pumping unit movable recovery equipment,presents its recovery mechanism diagram and the diagrammatic sketch of structure for fishing-oil-pump & fishing-oil-wellhead,and briefly introduces the recovery process principle of the truck-mounted pumping unit.The basic structure and work principle of the fishing-oil-pump & fishing-oil-wellhead that are necessary accessories of the truck-mountedpumping unit are discribed emphatically.It summarizes the serialization application well-condition for half-body-type fishing-oil-pump.%简要概括了称动式采油设备——车载抽油装置出现的背景情况,绘制了车载抽油装置的采油原理图及捞油泵、捞油井口的结构示意图,并结合图形结构扼要说明了车载抽油装置的基本结构和采油工艺原理。重点阐述了与车载抽油装置相配套的分体式捞油泵及捞油井口的基本结构和工作原理。总结了分体式捞油泵尺寸规格的系列化情况和应用井况。

  20. Operational control and diagnostics of the equipment by the parameters of the electric drive power supply by the example of deep well pump units

    Science.gov (United States)

    Shishlyannikov, D. I.; Vasilyeva, M. A.

    2017-02-01

    Currently, the vast majority of Russian oil wells use oil well pumping units (OPU), equipped with a mechanical drive - a balancing pumping unit. The significant lifetime of balancing pumping units used in oil fields of Russia amounts to full or close to full resource generation and to a high accident rate of the mechanical drive rod of OPU. Reduced material costs for operation and maintenance of OPU may be provided by the rejection of the system of preventive maintenance and service during the transition to the actual technical condition. The article analyzes the statistics of the most frequent crash balancing pumping units of OPU and their causes. The prospect of applying the method of instrument control parameters is proved, and the technical condition of the OPU is assessed based on the analysis of the magnitude and the nature of changes in load drive motors, determined by the recording of the instantaneous values of power consumption. The authors consider the construction and operation of the programmable controller ‘AKD-SK’ manufactured by JSC R&D company ‘ROS’ (Perm). Fundamentals of vattmetrogramm analysis of OPU drive motors are stated, and the character of displaying key defects of submersible pumps and balanced beam unit is described.

  1. Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump and Heat Recovery Equipment in EnergyPlus

    Energy Technology Data Exchange (ETDEWEB)

    Raustad, Richard; Nigusse, Bereket; Domitrovic, Ron

    2013-09-30

    The University of Central Florida/Florida Solar Energy Center, in cooperation with the Electric Power Research Institute and several variable-refrigerant-flow heat pump (VRF HP) manufacturers, provided a detailed computer model for a VRF HP system in the United States Department of Energy's (U.S. DOE) EnergyPlus? building energy simulation tool. Detailed laboratory testing and field demonstrations were performed to measure equipment performance and compare this performance to both the manufacturer's data and that predicted by the use of this new model through computer simulation. The project goal was to investigate the complex interactions of VRF HP systems from an HVAC system perspective, and explore the operational characteristics of this HVAC system type within a laboratory and real world building environment. Detailed laboratory testing of this advanced HVAC system provided invaluable performance information which does not currently exist in the form required for proper analysis and modeling. This information will also be useful for developing and/or supporting test standards for VRF HP systems. Field testing VRF HP systems also provided performance and operational information pertaining to installation, system configuration, and operational controls. Information collected from both laboratory and field tests were then used to create and validate the VRF HP system computer model which, in turn, provides architects, engineers, and building owners the confidence necessary to accurately and reliably perform building energy simulations. This new VRF HP model is available in the current public release version of DOE?s EnergyPlus software and can be used to investigate building energy use in both new and existing building stock. The general laboratory testing did not use the AHRI Standard 1230 test procedure and instead used an approach designed to measure the field installed full-load operating performance. This projects test methodology used the air

  2. EN LAS CAJAS DE AHORROS ESPAÑOLAS

    Directory of Open Access Journals (Sweden)

    Isidoro Guzmán

    2011-01-01

    Full Text Available El rendimiento del sector financiero español ha sido objeto de diversos estudios alo largo del decenio de los novena del sigloXXcomo consecuencia de los impor-tantes cambios a los que ha estado sometido. Las cajas de ahorros españolas nohan sido ajenas a este tipo de estudios, si bien circunscritos de manera exclusiva alexamen de su eficiencia y productividad, relegando a un segundo plano el análisisdel cumplimiento de su fin social, materializado económicamente en el gasto anualdestinado a obra social.En este contexto, la principal aportación de nuestro estudio es la obtención deevidencia empírica de la existencia de una relación de causalidad entre la creaciónde valor social de las cajas de ahorro españolas, medida por medio del estableci-miento de unratiode gasto social, y sus cambios en productividad, cuantificadosmediante el cálculo del índice de productividad de Malmquist basado en el trazadode fronteras eficientes a partir de la técnica no paramétrica del análisis envolvente dedatos (AED (Data Envelopment Analysis,DEA.Para el censo de cajas de ahorro españolas en el periodo 2003-2007, nuestrosresultados revelan que las entidades que presentan mayor productividad alcanzancotas superiores en elratiode gasto social, incluso después de controlar por medi-das tradicionales como la rentabilidad económica y el tamaño.

  3. Energy saving in the management of the BIMBO group distribution fleet; Ahorro de energia en la operacion de la flotilla de distribucion del grupo BIMBO

    Energy Technology Data Exchange (ETDEWEB)

    BIMBO Mexico

    2005-07-01

    In this work BIMBO demonstrates that in order to save energy it is necessary to invest in equipment, parts, research and people. This is why they got involved in the task of developing the projects of fuel cells participating with universities, associations, Secretaria de Energia, Comision Nacional de Ahorro de Energia (National Commission for Energy Saving) (CONAE) and the National Council for Science and Tecnologia (CONACYT), through financial supports with projects of mechanisms of clean development (Kyoto Protocol). For doing it they had to prove different types of fuels: biodiesel, hydrogen, alcohol and hybrids; for them to determine the most profitable and practical thus reducing the energy consumption. With the saving of fuels and lubricants in our vehicles, a greater yield in the company is obtained. [Spanish] En este trabajo BIMBO demuestra que para ahorrar energia hay que invertir en equipo, partes, investigacion y gente. Es por eso que se dieron a la tarea de desarrollar los proyectos de celdas de combustible, participando con universidades, asociaciones, la Secretaria de Energia, la Comision Nacional para el Ahorro de Energia (CONAE) y el Consejo Nacional para la Ciencia y Tecnologia (CONACYT), a traves de apoyos financieros con proyectos de mecanismos de desarrollo limpio (protocolo de Kyoto). Para ello tuvieron que probar diferentes tipos de combustibles: biodiesel, hidrogeno, alcohol e hibridos, para determinar los mas rentables y practicos y asi reducir el consumo de energia; con el ahorro de combustibles y lubricantes en nuestros vehiculos, logrando una mayor rentabilidad en la empresa.

  4. Strategies for energy saving in warm climate dwellings; Estrategias de ahorro de energia para viviendas en clima calido

    Energy Technology Data Exchange (ETDEWEB)

    Pilatowsky, I [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico (Mexico); Ramos Niembro, Gaudencio [Comision Nacional para el Ahorro de Energia -CONAE (Mexico); Morillon, David [Instituto de Ingenieria, Universidad Nacional Autonoma de Mexico (Mexico); Oskam, A. [Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-04-15

    The domestic sector consumes almost one quarter of the national electrical energy. In order to reduce in an important manner the power consumption in dwellings there is an integral alternative based on three elements: the bio-climatic design, the saving and efficient use of the energy in equipment and apparatuses, and the use of centralized air conditioning systems. Besides saving the electrical and thermal power consumption, with this scheme, comfort conditions are pretended to be reached in dwellings and, contributing at the same time, to the diminution of polluting emissions. [Spanish] El sector domestico consume casi una cuarta parte de la energia electrica nacional. Con objeto de reducir de manera importante el consumo de energia en las viviendas, se presenta una alternativa integral, basada en tres elementos: el diseno bioclimatico, el ahorro y uso eficiente de la energia en equipos y aparatos, y la utilizacion de sistemas de climatizacion centralizados. Ademas del ahorro en el consumo de energia electrica y termica, con este esquema se pretende alcanzar condiciones de confort en las viviendas y, al mismo tiempo, contribuir a la disminucion de emisiones contaminantes.

  5. Utilization of the computational technic for the promotion and diffusion of the energy conservation practice; Utilizacion de tecnicas computacionales para promocionar y difundir el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Kemper Valverde, N. [Laboratorio de Inteligencia Artificial, Instituto de Ingenieria, UNAM, Mexico D. F. (Mexico)

    1995-12-31

    In this paper are presented the developments obtained through the application of the new computational technologies in the diffusion and promotion tasks of energy efficient use and conservation. The most relevant aspects are described of three multimedia courses that were designed in order to increase the possibilities of offering personal training in efficient energy technic, as well as to have on hand totally open consulting and interactive tools. The courses that are described are: ``Design of Energy Conservation Programs for the Industry``, ``Energy Conservation in Combustion Equipment`` and ``Energy Cogeneration Technologies.`` On another subject, an analysis is also made of the possibilities for the development and application of expert systems that advise and give support to the work of technicians and engineers dedicated to energy conservation. The main characteristics of an expert system to give support to the energy analysis of lighting industrial systems, malls, buildings and hotels are also described. [Espanol] En este trabajo se presentan los desarrollos obtenidos por la aplicacion de las tareas de difusion y promocion del uso eficiente y ahorro de energia. Se describen los aspectos mas relevantes de tres cursos multimedia que fueron disenados con el objeto de incrementar las posibilidades de brindar capacitacion individualizada en tecnicas energeticas eficientes, asi como de contar con herramientas de consulta totalmente abiertas e interactivas. Los cursos que se describen son: ``Diseno de Programas de Ahorro de Energia en la Industria,`` ``Ahorro de Energia en Equipos de Combustion`` y ``Tecnologias de Cogeneracion de Energia.`` Por otro lado, tambien se hace un analisis de las posibilidades para el desarrollo y aplicacion de sistemas expertos que asesoren y apoyen el trabajo de tecnicos e ingenieros dedicados al ahorro de energia. Se describen las caracteristicas principales de un sistema experto disenado para brindar apoyo en analisis energeticos

  6. Cost estimation 2012 for the electrical and mechanical equipment of the power house in hydropower projects and pumped storage projects. Equipment with Pelton turbines, Francis turbines, Kaplan Turbines, Kaplan tube turbines, bulb turbines and Francis pump-turbines; Kostenschaetzung 2012 fuer die elektrische und mechanische Ausruestung des Krafthauses in Wasserkraft- und Pumpspeicher-Projekten. Ausruestung mit Pelton-, Francis-, Kaplan-, Kaplan-Rohr-, Bulb-Turbinen oder Francis-Pumpturbinen

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado-Ancieta, Cesar Adolfo

    2012-07-01

    The compilation of statistical data on costs for the electrical and mechanical equipment of approximately 140 selected hydropower projects and pumped storage projects in 46 countries in America, Europe, Asia and Africa provides helpful diagrams with which the cost of the electrical and mechanical equipment of Pelton turbines, Francis turbines, Kaplan Turbines, Kaplan tube turbines, bulb turbines and Francis pump-turbines can be determined.

  7. Factores determinantes del ahorro interno en América Latina

    Directory of Open Access Journals (Sweden)

    Carlos Añez

    2002-01-01

    Full Text Available El siguiente artículo aborda el problema del financiamiento de la inversión para un país en desarrollo, específicamente de la América Latina, tratando de revisar la literatura disponible para llegar a conclusiones sobre cómo los determinantes del ahorro en todas sus versiones -ahorro externo, ahorro privado y ahorro público- ejercen influencia sobre el proceso de crecimiento. Aun cuando la dirección causal exacta entre ahorro y crecimiento no ha sido establecida, el desarrollo de políticas económicas que estimulen el ahorro interno por encima del procedente del exterior, fortalecerían la capacidad de inversión interna y, al existir una correlación positiva entre estas variables, se potencia el proceso de crecimiento aunque otras variables igualmente pueden difuminar tal efecto. Se concluye que el incremento de la relación Ahorro Interno / P. I. B. sólo puede alcanzarse a través de esfuerzos comunes entre empresas, gobierno y el sistema financiero de estas economías.

  8. Pumping systems characterization; Caracterizacion de los sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Torres Gutierrez, R. [Eficiencia Energetica, S.A. de C.V., Mexico, D. F. (Mexico)

    1995-12-31

    In this paper the characterization of the pumping systems is discussed, and an explanation is given of the need of evaluating in detail the possibility of implementing the frequency variators as an option for energy conservation, explaining how the simple use of the similarity or affinity laws lead to over-estimate the saving. [Espanol] En este articulo se describe la caracterizacion de los sistemas de bombeo y se explica la necesidad de evaluar en detalle la posibilidad de implementacion de variadores de frecuencia, como una alternativa para el ahorro de energia, explicando como el simple uso de las leyes de semejanza o afinidad llevan a sobre-evaluar los ahorros.

  9. ABSORCIÓN DE AHORRO INTERNO POR EL GOBIERNO NACIONAL

    Directory of Open Access Journals (Sweden)

    Álvaro José Pedroza Campo

    2002-01-01

    Full Text Available El gobierno colombiano ha financiado durante los últimos cinco años el déficit fiscal en gran medida con recursos provenientes del ahorro nacional, a través de emisiones de títulos en condiciones de rentabilidad innecesariamente altas, frenando la tendencia de disminución de tasas de interés internas. Adicionalmente, la estructura institucional gubernamental a través de la cual se realiza la colocación primaria y la negociación secundaria de dichos títulos, genera una competencia desigual que desplaza a los demás agentes económicos, especialmente el sector productivo, como captadores de recursos del mercado de capitales para financiar sus negocios. Lo anterior ha ocurrido en un período caracterizado por crisis del sector financiero y recesión económica.

  10. Project of energy saving in compressed air; Proyecto de ahorro de energia en aire comprimido

    Energy Technology Data Exchange (ETDEWEB)

    Automatizacion, Productividad y Calidad S.A. de C.V. Puebla, (Mexico)

    2005-07-01

    The objective of this project is to reduce the operation costs by means of the energy saving through the use of the compressed air system. For this purpose the solenoid valves controlled per time and the manually acted valves of sphere must be replaced by pneumatic purges that remove from the system the condensed humidity without discharging air and which act automatically when the water reaches the level of unloading in its deposit. The pressure level is the reduction of the operation rank of pressure in the compressors, satisfying the operation requirements of the process equipment. [Spanish] El objetivo de este proyecto es reducir el costo de operacion mediante el ahorro de energia en la utilizacion del sistema de aire comprimido. Para ello se tienen que remplazar las valvulas solenoides controladas por tiempo y valvulas de esfera actuadas manualmente por purgas neumaticas que remueven del sistema la humedad condensada sin descargar aire y que actuan en forma automatica al alcanzar el agua el nivel de descarga en su deposito. El nivel de presion es la reduccion del rango de operacion de presion de los compresores, satisfaciendo los requerimientos de operacion de los equipos de proceso.

  11. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  12. Risk control in energy saving projects; Control de riesgo en los proyectos de ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Evan [Lawrence Berkeley National Laboratory, CA (United States)

    2005-10-15

    Since one of the restrictive problems when investing in energy saving is the uncertainty of obtaining the planed savings, a technique in the risk handling for energy efficiency projects, called Insurance for the Energy Saving (IES) is presented. IES economically stimulates those who implement projects for energy saving so they go beyond the normal measures and really obtain significant saving levels, thus contributing to the fulfillment of national objectives in energy saving. In order to reduce the risk of low performance in energy caused by saving projects there exist the international performance measurement and the protocol of investment (IMPVP) as well as diagnoses and starting processes, whereas in order to transfer the financial risk that a saving project represents, mechanisms such as FDIC insurance, conversion of the debt in values, Saving's Guarantees, Performance Bonuses or Guarantee Bonuses and Insurances for Energy Saving can be of great help. This article deals on the IES insurance policies, their loss control management, successful cases, benefits, particular advantages, place in the market and refers argued insurance exceptions and perception surveys. [Spanish] Dado que uno de los problemas restrictivos a la hora de invertir en el ahorro de energia es la incertidumbre de obtener los ahorros proyectados, se presenta una tecnica en el manejo del riesgo para proyectos de eficiencia energetica llamada Seguro para el Ahorro de Energia (SAE). SAE estimula financieramente a quienes implementan proyectos para el ahorro de energia con el fin de que vayan mas alla de las medidas normales y consigan niveles significativos de ahorro, contribuyendo asi al cumplimiento de objetivos nacionales de ahorro energetico. Para reducir el riesgo de bajo desempeno de energia provocados por proyectos de ahorro existe la medicion del desempeno internacional y el protocolo de inversion (IMPVP) asi como diagnosticos y procesos de arranque, mientras que para transferir el

  13. Diferencias de género en los factores asociados al ahorro de los hogares en México

    OpenAIRE

    Isalia Nava Bolaños; Flor Brown Grossman; Lilia Domínguez Villalobos

    2014-01-01

    A diferencia de los trabajos que analizan el ahorro suponiendo un hogar unitario, esta investigación se centra en las diferencias en las decisiones de ahorro de los hogares con jefaturas femenina y masculina en México. Los resultados del modelo Tobit muestran que los factores que afectan al ahorro son distintos entre ellos. La escolaridad (primaria y secundaria) y los apoyos gubernamentales no inciden en las tasas de ahorro de las jefaturas masculinas, pero sí en las femeninas. Se confirma la...

  14. Flash-lamp-pumped 4 J, 50 Hz Nd:YAG nanosecond laser system for mobile and transportable equipment

    Science.gov (United States)

    Mikami, Katsuhiro; Hasegawa, Noboru; Okada, Hajime; Kondo, Shuji; Nishikino, Masaharu; Kawachi, Tetsuya

    2017-08-01

    A simplified flash-lamp pumped high-average-power Nd:YAG nanosecond laser system based on a master oscillator power amplifier platform was developed toward outside laser remote sensing. The performance of the laser system was demonstrated, obtaining 4 J output pulse energy with a 50 Hz operating frequency. Thermal lens effects were compensated for by using only simple image relays and up to 97% of the laser energy could be contained in the focal spot. The developed laser system was constructed using only components suitable for operation under outside conditions.

  15. Introduction criteria and concepts on energy saving in the technical standards for electric installations; Introduccion de criterios y conceptos de ahorro de energia en las normas tecnicas para instalaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Rincon Nader, Jorge A. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-12-31

    The project Introduction Criteria and Concepts on Energy Saving in the Technical Standards for electric installations, is described, whose immediate objective is to recommend and in some cases regulate the use of energy saving equipment and devices and the adoption of attitudes and procedures that convey into saving, and the rational and efficient use of the electric energy. [Espanol] Se describe el proyecto Introduccion de Criterios y Conceptos de Ahorro de Energia en las Normas Tecnicas para instalaciones electricas, que tiene como objetivo inmediato recomendar, y en algunos casos reglamentar el uso de equipos y dispositivos ahorradores y la adopcion de actitudes y procedimientos que conduzcan a un ahorro y uso racional y eficiente de la energia electrica.

  16. Design and simulation of heat pumps and A/C equipment using pure and mixed refrigerants with MoMo (Modular Modelling)

    Energy Technology Data Exchange (ETDEWEB)

    Bensafi, A. [CETIAT, Centre Technique des Industries Aerauliques et Thermiques, 69 - Villeurbanne (France)

    1999-07-01

    An approach to the steady-state simulation of A/C, heat pumping and refrigerating equipment is presented. Novel features of the proposed model are the strategy and formalism adopted. Individual mathematical models for component design are dynamically linked to enable the simulation of a vapour compression cycle. This paper introduces some of the component modules, which can be used for pure as well as mixed refrigerants. Because numerous models can be used for specific pieces of equipment making up the whole refrigerating/heating unit, the Modular Modeling approach leads to a flexible and evolutive structure. The effects of operating conditions, refrigerant charge, or component geometrical parameters on cycle performance can then be examined. Because actual test data are used to 'calibrate' the component modules, very accurate results are obtained. The proposed model is validated with experimental results. Discrepancies smaller than 5% are obtained on the cooling duty and COP. An air conditioning unit using high pressure refrigerant R410A is optimised to illustrate the use of the model. (authors)

  17. Electric power conservation while using pumping systems; Conservacion de Energia Electrica en Sistemas de Bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Nambiar, P

    2007-01-15

    The pumping systems provide about 20 to 25 percent of energy which is necessary worldwide: it is fruitful to understand how to use electric power efficiently, to achieve the reduction regarding expenses a pumping system implies.It is essential to possess a better knowledge about the pumping system and its applications, in order to be able to use energy responsibly. If people do not how to operate this kind of systems properly, they will use inadequate equipment that will cause an energy waste. In addition it is important to know: alternative methods to meet variable demands, an adapted system to pump water requirements in order to ensure the pump work in its pumping point, and the life cycle system cost for the energy saving in the long term. [Spanish] En promedio del 20 al 25% de la energia necesaria en el mundo proviene de los sistemas de bombeo, por tal razon es importante saber como utilizar la energia electrica con eficiencia para asi lograr reducir los gastos que este tipo de sistemas implican. Para poder hacer un buen uso de la energia, es necesario que se tenga un conocimiento mayor del sistema de bombeo y aplicacion, ya que la ignorancia sobre esto exige el uso de aparatos que contribuyen al desperdicio de la energia; por otro lado tambien es esencial conocer metodos alternos para demandas variables, tener un sistema que se adapte a las necesidades de bombeo del agua para asegurarse de que cada bomba trabaje cerca de su punto de bombeo y finalmente conocer el costo del ciclo de vida del sistema para el ahorro de energia a largo plazo.

  18. Interactive applications for energy saving; Aplicaciones interactivas para ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Adame Gonzalez, Alejandro; Ramirez Anaya, Cesar; Gutierrez, Hector; Dominguez Ojeda, Xerxes; Aguilar Galvan, Alfredo [Ingenieria Energetica Integral S. A. de C. V., Mexico, D. F. (Mexico)

    1998-12-31

    A series of ideas are presented that can help in the development of interactive applications for energy saving. Emphasis is made on the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE)`s Interactive Course on Demand Management and Power Factor Compensation, in order to demonstrate how far one can go with the multimedia development. [Espanol] Se presenta un conjunto de ideas que pueden auxiliar en la elaboracion de aplicaciones interactivas para ahorro de energia. Se hace principal enfasis sobre el curso interactivo Administracion de la Demanda y Compensacion del Factor de Potencia del Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) con la finalidad de mostrar hasta donde puede llegarse con un desarrollo multimedia.

  19. Diferencias de género en los factores asociados al ahorro de los hogares en México

    Directory of Open Access Journals (Sweden)

    Isalia Nava Bolaños

    2014-01-01

    Full Text Available A diferencia de los trabajos que analizan el ahorro suponiendo un hogar unitario, esta investigación se centra en las diferencias en las decisiones de ahorro de los hogares con jefaturas femenina y masculina en México. Los resultados del modelo Tobit muestran que los factores que afectan al ahorro son distintos entre ellos. La escolaridad (primaria y secundaria y los apoyos gubernamentales no inciden en las tasas de ahorro de las jefaturas masculinas, pero sí en las femeninas. Se confirma la asociación negativa de las horas dedicadas al trabajo doméstico con la tasa de ahorro en los hogares de jefatura femenina.

  20. Instituciones microfinancieras y cajas de ahorro en Santo Tomás Hueyotlipan, Puebla

    OpenAIRE

    2014-01-01

    La exigua presencia de los intermediarios financieros formales en los municipios rurales mexicanos impulsa el uso de tandas y solicitud de dinero a prestamistas, familiares o amigos. Las cajas de ahorro constituyen una alternativa a estos métodos tradicionales y aprovechan el capital social comunitario. Esta investigación, fundamentado en una muestra realizada en el municipio de Santo Tomás Hueyotlipan (Puebla, México), analiza los factores que impulsan la participación en las cajas de ahorro...

  1. Acción Nulidad en Afiliaciones al Régimen de Ahorro Individual

    OpenAIRE

    Buriticá Atehortúa, Carlos Arturo; Ing Pensiones y Cesantías – Manizales

    2015-01-01

    Objetivo: determinar la posibilidad de la acción de nulidad de las afiliaciones al Régimen de Ahorro Individual. Metodología: este es un ensayo argumentativo que estudia con Prestación Definida al Régimen de Ahorro Individual con Solidaridad bajo los preceptos jurídicos desde la entrada en vigencia de la ley 100 de 1993 y la comparación con otros países como Argentina y Chile, y se encuentra que esta acción es posible. Conclusiones: según los argumentos en materia de proyección económica y de...

  2. 46 CFR 169.559 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 169.559 Section 169.559 Shipping COAST GUARD... Firefighting Equipment Firefighting Equipment § 169.559 Fire pumps. (a) Each sailing school vessel must be equipped with fire pumps as required in Table 169.559(a). Table 169.559(a)—Fire Pumps Length Exposed...

  3. Microfinanzas y Remesas: La Experiencia de Cooperativas de Ahorro y Crédito

    OpenAIRE

    Dave Grace

    2003-01-01

    Presentación que da a conocer el funcionamiento de la Red Internacional de Remesas - IRnet en los países de México, Honduras, Jamaica, El Salvador y Guatemala. Asimismo, brinda información acerca de las lecciones aprendidas del Consejo Mundial de Cooperativas de Ahorro y Crédito (WOCCU), así como sus futuros proyectos.

  4. Microfinanzas y Remesas: La Experiencia de Cooperativas de Ahorro y Crédito

    OpenAIRE

    Dave Grace

    2003-01-01

    Presentación que da a conocer el funcionamiento de la Red Internacional de Remesas - IRnet en los países de México, Honduras, Jamaica, El Salvador y Guatemala. Asimismo, brinda información acerca de las lecciones aprendidas del Consejo Mundial de Cooperativas de Ahorro y Crédito (WOCCU), así como sus futuros proyectos.

  5. Strategies for energy saving in buildings by means of automatic control; Estrategias de ahorro de energia en inmuebles mediante el control automatico

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Trujillo, Oscar [Johnson Controls de Mexico S. A. de C. V., Mexico, D. F. (Mexico)

    1998-12-31

    In this paper some of the measures and strategies for energy saving that can be applied in different types of buildings, mainly in hotels and office buildings, are presented. The proposed actions are accomplished with the aid of the automatic control equipment and the operation and/or maintenance personnel that supervises and establishes the control parameters of each one of the strategies than are focused to the appropriate utilization of the electric energy. [Espanol] En este documento se presentan algunas de las medidas y estrategias de ahorro de energia que pueden ser aplicadas en diferentes tipos de inmuebles, principalmente en hoteles y en edificios de oficinas. Las acciones propuestas son realizadas con la ayuda del equipo de control automatico y del personal de operacion y/o mantenimiento quien supervisa y establece los parametros de control de cada una de las estrategias que son destinadas a la buena utilizacion de la energia electrica.

  6. Energy conservation programs of Pemex exploration and production, south region; Programas de ahorro de energia en Pemex exploracion y produccion, region sur

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Milla, Guillermo; Garcia Juarez, Francisco; Alarcon Aleman, Jose Mauricio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The technological developments of energy economizing equipment constitute a powerful tool for the conservation and saving of the electric energy in new or existing installations. Petroleos Mexicanos (PEMEX) Exploration and Production initiated in 1997 a program for energy economizing in the South region, for which the Instituto de Investigaciones Electricas, through its Unit for the Use of Energy, collaborated performing energy assessments in 115 buildings of the above mentioned region. This paper describes the employed methodology to carry on the energy assessment, which consisted in an analysis of each building and different options for energy economizing were presented, which was accompanied with cost-benefit studies. The results obtained show that the air conditioning equipment and lighting represent the most important loads permanently connected, therefore the study was concentrated in these two loads [Espanol] Los desarrollos tecnologicos de equipos ahorradores de energia constituyen una poderosa herramienta para la conservacion y el ahorro de energia electrica en instalaciones nuevas o existentes. Petroleos Mexicanos (PEMEX) Exploracion y Produccion inicio en 1997 un programa para el ahorro de energia en la region sur, para lo cual el Instituto de Investigaciones Electricas, a traves de la Unidad de Uso de Energia, colaboro realizando diagnosticos energeticos en 115 edificios de dicha region. En este documento se describe la metodologia utilizada para realizar el diagnostico energetico, el cual consistio en un analisis de cada edificio y se presentaron diversas opciones para ahorrar energia, lo cual se acompano de estudios de costo-beneficio. Los resultados obtenidos muestran que los equipos de aire acondicionado e iluminacion representan la parte mas importante de las cargas conectadas permanentemente, por lo que el estudio se concentro en estas dos cargas

  7. 33 CFR 183.524 - Fuel pumps.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel pumps. 183.524 Section 183... SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.524 Fuel pumps. (a) Each diaphragm pump must not leak fuel from the pump if the primary diaphragm fails. (b) Each...

  8. La reforma del sistema financiero: cajas de ahorros.- (Años 2011-2012

    Directory of Open Access Journals (Sweden)

    Octavio Vázquez Sotelo

    2013-04-01

    Full Text Available Este trabajo forma parte del libro “La dimensión social de las Cajas de Ahorro: España y Galicia”, publicado por la Editorial Académica Española, del cual soy autor.A través de la legislación promulgada en los años 2010, 2011 y 2012, se analiza la estrategia de privatización de las Cajas de Ahorro seguida por los gobiernos de turno que, en la mayor parte de los casos, ha supuesto la entrega de las mismas a precios irrisorios a su tradicionales competidores: la gran Banca.. Ello ha comportado la desfiguración o, incluso, la desaparición del rasgo más distintivo de aquellas: la Obra Social.

  9. Instituciones microfinancieras y cajas de ahorro en Santo Tomás Hueyotlipan, Puebla

    Directory of Open Access Journals (Sweden)

    Kristiano Raccanello

    2014-01-01

    Full Text Available La exigua presencia de los intermediarios financieros formales en los municipios rurales mexicanos impulsa el uso de tandas y solicitud de dinero a prestamistas, familiares o amigos. Las cajas de ahorro constituyen una alternativa a estos métodos tradicionales y aprovechan el capital social comunitario. Esta investigación, fundamentado en una muestra realizada en el municipio de Santo Tomás Hueyotlipan (Puebla, México, analiza los factores que impulsan la participación en las cajas de ahorro informales y su interacción con otros intermediarios financieros informales. Los resultados del modelo probit indican que la participación responde a la posibilidad de poder ahorrar atrayendo a aquellos individuos que no utilizan tandas, prestamistas o deudas con familiares o amigos.

  10. El efecto del alfabetismo financiero en el ahorro para el retiro en México.

    OpenAIRE

    F. Alejandro Villagómez; Alayn González

    2014-01-01

    En este trabajo analizamos si es posible incrementar el ahorro para el retiro por medio de alfabetismo financiero en México. Con información de la Encuesta Nacional de los Niveles de Vida de los Hogares 2005 (ENNVIH-2) construimos un índice de alfabetizo financiero siguiendo la metodología propuesta por Atkinson y Messy (2012) que considera tres factores: conocimiento, actitudes y comportamiento financiero. Nuestros resultados sugieren que el alfabetismo financiero tiene un impacto positivo e...

  11. México: la economía de los sectores institucionales, distribución del ingreso, ahorro y crecimiento

    OpenAIRE

    Roberto Michel Padilla

    2003-01-01

    A partir del análisis de las cuentas nacionales de México por sector institucional se descubre una relación de sustitución perfecta entre el ahorro externo y el ahorro interno. Cambios en la disponibilidad de ahorro externo generan, mediante diferentes mecanismos, variaciones en el mismo sentido en la participación de los salarios y los dividendos en el producto y en sus propensiones al consumo; y en sentido opuesto en el ahorro interno de las empresas. La relación de causalidad es clara; a m...

  12. Nissan Mexicana. First place in national prize of electrical energy saving 1998; Nissan Mexicana. Primer lugar en premio nacional de ahorro de energia electrica 1998

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez S, Enrique [Nissan Mexicana, S.A. de C.V., Planta Civac, Cuernavaca, Mor. (Mexico)

    1999-07-01

    For Plant CIVAC of Nissan Mexicana, the energy saving began in the year of 1990. From then, different programs have been developed using different strategies for energy saving until arriving at the Benchmarking with other Plants of Japan, which represents a new challenge, since it opened up an area of opportunity of saving in processes that generally were known in detail as far as to its main function (to make vehicles with quality, cost and opportunity of delivery), but the parameter of energy consumption of by unit and its benefits in relation to the cost was unknown. This was endorsed by the high Direction and began with the optimization of training for the operation of each equipment with the involvement of the user (Production), the engineering area (that establishes the process) and the maintenance area. We designed a general program where the basic activities were included, such as the general and special activities. Each one of them fulfilled its objective, but the special activities took us to the optimization of the processes, finding excess of energy in the design conditions. [Spanish] Para Planta CIVAC de Nissan Mexicana, el ahorro de energia se inicio en el ano de 1990. A partir de entonces se han desarrollado programas de ahorro de energia usando estrategias diferentes hasta llegar al Benchmarking con otras Plantas de Japon, el cual representa un reto nuevo, ya que puso al descubierto una area de oportunidad de ahorro en los procesos que por lo general se conocian a detalle en cuanto a la funcion principal (hacer vehiculos con calidad, costo y oportunidad de entrega), pero se desconocia el parametro de consumo de energia por unidad y sus beneficios en relacion con el costo. Esto fue avalado por la alta Direccion y se inicio con la capacitacion de la optimizacion de la operacion de cada equipo y se involucro al usuario (Produccion), al area de ingenieria (que establece el proceso) y al area de mantenimiento. Elaboramos un programa general donde se

  13. 33 CFR 157.126 - Pumps.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Pumps. 157.126 Section 157.126... Washing (COW) System on Tank Vessels Design, Equipment, and Installation § 157.126 Pumps. (a) Crude oil must be supplied to the COW machines by COW system pumps or cargo pumps. (b) The pumps under...

  14. Pilot projects in window type air conditioning equipment in the domestic sector; Proyectos piloto en equipos de aire acondicionado tipo ventana en el sector domestico

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Ricardo [Instituto Politecnico Nacional (Mexico)

    2001-09-01

    The present paper shows the energy saving that can be obtained in the domestic sector when replacing window type air conditioning equipment of low efficiency by equipment of greater efficiency, as well as the necessary parameters to identify such results, derived from the pilot projects of substitution being developed by the Fideicomiso para el Ahorro de Energia Electrica (FIDE) at the moment. [Spanish] El presente trabajo muestra los ahorros de energia que pueden obtenerse en el sector domestico al sustituir equipos de aire acondicionado tipo ventana de baja eficiencia, por equipos de mayor eficiencia, asi como los parametros necesarios para identificar tales resultados, derivados de los proyectos pilotos de sustitucion que desarrolla actualmente el Fideicomiso para el Ahorro de Energia Electrica (FIDE).

  15. 双作用三直线电机往复泵试验装置研究%Research on the Test Equipment of Double Acting Triple Linear Motor Reciprocating Pump

    Institute of Scientific and Technical Information of China (English)

    张培志; 侯勇俊; 蔡科涛; 龙磊

    2012-01-01

    针对传统往复泵结构复杂、效率低、输出流量和压力波动大、维修不方便等缺点,提出并研制了一种双作用三直线电机往复泵试验装置.该装置以计算机为核心,具体由通用变频器、三相圆筒型感应直线电机、PCI数据采集卡和传感器等设备组成.通过系统软件编程,实现了单直线电机驱动往复泵试验和三直线电机协调控制往复泵试验.试验结果验证了理论研究的正确性.%To against the disadvantages of traditional reciprocating pumps, e. g. , complicated structure, low efficiency, large fluctuation of output (low and pressure, and difficult to maintain, the test equipment of double acting triple linear motor reciprocating pump is proposed and developed. With computer as the kernel, the equipment is composed of commonly used inverter, three-phase cylindrical inductive linear motor, PCI data acquisition card and sensors, etc. Through software programming, the test of single linear motor driving reciprocating pump and the test of triple linear motor coordinated control reciprocating pump are implemented. The result of tests verifies the correctness of the theoretical research.

  16. Energy saving in Bellota Mexico S.A. de C.V.; Ahorro de energia en Bellota Mexico S.A de C.V.

    Energy Technology Data Exchange (ETDEWEB)

    Salazar Lopez, Jose Albeiro [Bellota Mexico S.A. de C.V. (Mexico)

    2003-07-01

    The present article intends to make a general description of the different activities that were developed in Bellota Mexico S.A. de C.V. during year 2001 and which lead to obtaining the national prize of energy saving granted by the Comision Federal de Electricidad (CFE) and the Fideicomiso para el Ahorro de Energia Electrica (FIDE). In the executed actions stands out an entirely coordinated program that includes: lighting systems, motors, refrigeration systems, transformers, special projects (settling tanks), capacitors, compressed air pipeline, induction furnaces, machinery in general, maximum demand control, preventive maintenance, measuring systems, operational and organizational systems. In all these subjects a fast description is made of the performed actions and the obtained results. It is mentioned in addition the importance of making a power diagnosis and the use of historical data for the planning of the strategies to follow. Also reference is made of the use of appropriate technology that considers the use of high-energy efficiency equipment, such as motors, lamps, compressors, etc. Finally an evaluation is made of the obtained results where the improvement of the electrical parameters stands out such as: reduction of the power index in 35.06%, reduction of the maximum demand in 11.94%, increase of the power factor from 93.53% in 98.21%. The obtained results demonstrate that investing in energy saving it is a good business. [Spanish] El presente trabajo tiene por objeto hacer una descripcion general de las diferentes actividades que se desarrollaron en Bellota Mexico S.A. de C.V. durante el ano 2001 y que condujeron a la obtencion del premio nacional de ahorro de energia otorgado por la Comision Federal de Electricidad (CFE) y el Fideicomiso para el Ahorro de Energia Electrica (FIDE). En las acciones ejecutadas se destaca todo un programa coordinado que abarca: sistemas de iluminacion, motores, sistemas de refrigeracion, transformadores, proyectos

  17. Electric energy saving in the cellulose and paper industry; Ahorro de energia electrica en la industria de celulosa y papel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-12-31

    This paper delineates the results of the demonstration project for electric energy saving, which is one of the twenty four projects in which the Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) sponsors the diagnosis as well as the applied measures and the measures currently in application. Also the potential opportunity areas and the measures applied and in course of application, as well as the required investments and their recuperation periods. [Espanol] En este trabajo se describen los resultados del proyecto de demostracion de ahorro de energia electrica que es uno de los veinticuatro proyectos, en los que el Fideicomiso de Apoyo al Programa de Ahorro de Energia (FIDE) financia tanto el diagnostico como la aplicacion de medidas. Se presentan tanto las areas de oportunidad, potenciales y medidas aplicadas y en aplicacion, asi como las inversiones requeridas y los periodos de recuperacion de las mismas.

  18. Auditoría forense aplicada a cooperativas de ahorro y crédito

    OpenAIRE

    Almendáriz Romero, Silvia Margoth

    2008-01-01

    El propósito de este trabajo es presentar una propuesta, a los profesionales de la auditoria interna de las cooperativas de ahorro y crédito, sobre la aplicación de procedimientos de auditoria forense, como una alternativa para la detección, prevención y si cabe, la sanción de actos fraudulentos o dolosos cometidos por los directivos, administradores y empleados de este tipo de instituciones. El desarrollo de la tesis se realizó mediante el análisis, estudio y evaluación de la información ...

  19. Estructura del hogar y ahorro durante el ciclo de vida: Evidencia de las cohortes peruanas

    OpenAIRE

    Valdivia, Martín; Saavedra, Jaime

    2003-01-01

    Los cambios demográficos que ocurren en el Perú y en el resto de países en desarrollo tienen implicancias potenciales sobre un conjunto de sectores, en particular sobre el sistema de seguridad social para la vejez. La naturaleza de los efectos, sin embargo, depende del comportamiento de los individuos, y sus hogares, a lo largo del ciclo de vida; por ejemplo, en lo concerniente a sus decisiones laborales (momento de retiro) y de ahorro, las que a su vez están relacionadas con los arreglos int...

  20. Prospectiva del Programa de Ahorro Sistemático Integral en Mexicali, Baja California, México

    OpenAIRE

    José A. Suástegui Macías; Carlos Pérez Tello; H. Enrique Campbell; Hernán D. Magaña Almaguer

    2013-01-01

    El propósito de este trabajo es brindar información actualizada que permita elaborar una prospectiva del programa impulsado por el gobierno federal mexicano bajo el nombre de Programa de Ahorro Sistemático Integral (ASI) para el ahorro y uso eficiente de energía en el sector vivienda de Mexicali, Baja California. El presente estudio se realiza utilizando datos históricos del programa desde 1990 a la fecha e históricos de consumo de usuarios del servicio eléctrico. Se analiza la evolución del ...

  1. Aislamiento, bienestar y ahorro de energía

    Directory of Open Access Journals (Sweden)

    García Arroyo, A.

    1976-03-01

    Full Text Available The continous appearance of new materials, the general tendency towards lighter structural charges, the increased personal welfare levels, the extended use of mechanical equipments for environmental conditioning in most of the housings presently being constructed, and the incessant and considerable increase of the organic fuel costs have given rise to a new study, both in scope and precision, of the physical and construction basis of the fundamental problems of living spaces. Here the study of the installations deals with arrangements suitable for carrying out the architectural projects of the construction elements, in order to obtain their maximum efficiency, as regulators of the negative environmental influences. As already announced previously, this is the second of three articles published in three consecutive issues of INFORMES DE LA CONSTRUCCIÓN.La continua aparición de nuevos materiales, la tendencia general al aligeramiento de las cargas estructurales, el incremento de los niveles individuales de bienestar, la extensión de los equipos mecánicos de acondicionamiento ambiental a la mayoría de las viviendas actualmente en construcción, y el ininterrumpido y sustancial crecimiento en los costos de los combustibles orgánicos, han dado lugar al replanteamiento, en extensión y profundidad, de las bases físico-constructivas en las que descansa la problemática funcional de los recintos habitacionales. Se aborda aquí el estudio de las disposiciones constructivas idóneas para la práctica de los proyectos arquitecturales de los diferentes elementos constructivos, a fin de obtener su máxima funcionalidad como reguladores de las solicitaciones ambientales perturbadoras del bienestar. Como ya se advirtió, éste es el segundo artículo de la serie de tres que aparecen en 3 números sucesivos de INFORMES DE LA CONSTRUCCIÓN.

  2. Aislamiento, bienestar y ahorro de energía

    Directory of Open Access Journals (Sweden)

    García Arroyo, Arturo

    1976-04-01

    Full Text Available The continuous appearance of new materials, the general tendency towards lighter structural loads, the increased personal welfare levels, the extended use of mechanical equipments for environmental conditioning in most of the housings presently being constructed, and the incessant and considerable increase of the organic fuel costs have given rise to a new study, both in scope and precision, of the physical and construction basis of the fundamental problems of living spaces. A comparative study is here carried out of the existing national and foreign Norms on the hygrothermal requirements that the members, and the spaces they form, have to comply with, so as to obtain comfort within the budget limits of an effective economy. As already mentioned, this is the last one of three articles published in consecutive issues of INFORMES DE LA CONSTRUCCIÓN.La continua aparición de nuevos materiales, la tendencia general al aligeramiento de las cargas estructurales, el incremento de los niveles individuales de bienestar, la extensión de los equipos mecánicos de acondicionamiento ambiental a la mayoría de las viviendas actualmente en construcción, y el ininterrumpido y sustancial crecimiento en los costos de los combustibles orgánicos, han dado lugar al replanteamiento, en extensión y profundidad, de las bases físico-constructivas en las que descansa la problemática funcional de los recintos habitacionales. Se aborda aquí el estudio comparado de la reglamentación existente, nacional y extranjera, de las necesidades higrotérmicas que han de cumplir los elementos y los recintos que éstos delimitan, para la consecución del confort, dentro de los presupuestos de una efectiva economía. Como ya se advirtió, éste es el último artículo de la serie de tres que han aparecido en números sucesivos de INFORMES DE LA CONSTRUCCIÓN.

  3. Aislamiento, bienestar y ahorro de energía

    Directory of Open Access Journals (Sweden)

    García Arroyo, A.

    1976-02-01

    Full Text Available The continous appearance of new materials, the general tendency towards lighter structural charges, the increased personal welfare levels, tile extended use of mechanical equipments for environmental conditioning in most of the housings presently being constructed, and the incessant and considerable increase of the organic fuel costs have given rise to a new study, both in scope and precision, of the physical and construction basis of the fundamental problems of living spaces. In addition to the financial and engineering aspects of the separate installations the problem is here approached through three different angles: I. Analysis of the thermophysical characteristics of the materials and structural elements that define and quantify the insulating capacity of these. II. Constructive arrangements suitable for carrying out the architectural projects of the construction elements, in order to obtain their maximum efficiency, as regulators of the negative environmental influences. III. A relative study of existing national and foreign regulations of the hygrothermal needs that the elements and structural spaces must meet to achieve the required comfort within the envisaged budget. Each of the above mentioned items will be dealt with in this Journal from this number onwards.La continua aparición de nuevos materiales, la tendencia general al aligeramiento de las cargas estructurales, el incremento de los niveles individuales de bienestar, la extensión de los equipos mecánicos de acondicionamiento ambiental a la mayoría de las viviendas actualmente en construcción, y e! ininterrumpido y sustancial crecimiento en los costos de los combustibles orgánicos, han dado lugar al replanteamiento, en extensión y profundidad, de las bases físico-constructivas en las que descansa la problemática funcional de los recintos habitacionales. Consideraciones financieras o de ingeniería de las instalaciones aparte, se aborda aquí el estudio del

  4. EL AHORRO PARA EL RETIRO. Una reflexión para México

    Directory of Open Access Journals (Sweden)

    F. Alejandro Villagómez

    2014-01-01

    Full Text Available Desde hace tiempo existe una señalada preocupación entre académicos y autoridades en muchos países sobre si los individuos están realizando el ahorro necesario para su fase de retiro. La evidencia empírica muestra que en los países desarrollados no es así, y lo mismo indica la poca evidencia disponible para países en desarrollo. En este trabajo se hace una revisión de la literatura teórica sobre este tema, en particular del modelo de ciclo de vida, así como de otros planteamientos que contribuyen a explicar el fenómeno. Se hace hincapié en el caso mexicano y para ello se ofrece la escasa evidencia disponible sobre el ahorro para el retiro de su población y se muestra que éste no es adecuado en la mayoría de los casos. Se concluye con algunas reflexiones útiles para diseñar políticas públicas que permitan enfrentar este problema

  5. 46 CFR 181.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 181.300 Section 181.300 Shipping COAST GUARD... EQUIPMENT Fire Main System § 181.300 Fire pumps. (a) A self priming, power driven fire pump must be..., the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of...

  6. Evaluación del desempeño del plan de ahorro de la compañía Andes Petroleum

    OpenAIRE

    Egas Romero, José Luis

    2015-01-01

    El presente estudio está enfocado en evaluar el plan de ahorro de los empleados de la compañía Andes Petroleum Ecuador Ltd. como un beneficio de retención y capacidad de ahorro de los empleados mediante aportaciones mensuales personales y de la compañía.Se prevé analizar los resultados obtenidos por este plan de ahorros como un beneficio que apalanca la retención de personal en la compañía Andes Petroleum Ecuador Ltd. En vista de que siendo un beneficio adicional al salario de los empleados a...

  7. Quarry Equipment Yearbook 2003

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This issue of the journal is devoted to an annual review of developments in the equipment used for minerals extraction and recycling. For each of 12 types of equipment, an editorial review is presented of developments and a tabular presentation of suppliers' ranges and contact information, including e-mail addresses and websites. The sections are: asphalt plants, conveyors, crushers and screens, drill rigs, dump trucks, excavators, hammers, pumps, tyres, weighbridges, wheel loaders and wheel washers.

  8. Submersible pumps: Energetic efficiency norm; Bombas sumergibles: norma de eficiencia energetica

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R. A.; Buendia Dominguez, E. H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE), has prepared a preliminary project of the norm of energy efficiency for submersible pumps. This document has complied with the necessary formalities for the emission of the norm. This paper presents the results of the analysis of the submersible pumps, the energy savings, as well as the economic evaluation that sustains the norm project, additionally pointing out the environmental impact that will bring along the implantation of the same. [Espanol] El Instituto de Investigaciones Electricas (IIE), apoyando a la Comision Nacional para el Ahorro de Energia (CONAE), ha elaborado el anteproyecto de norma de eficiencia energetica para bombas sumergibles. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma. En el presente articulo se mencionan los resultados del analisis de las bombas sumergibles, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  9. Normalization of the energy efficiency in pumping systems; Normalizacion de eficiencia energetica en sistemas de bombeo

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, R.A.; Buendia Dominguez, E.H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1995-12-31

    The Instituto de Investigaciones Electricas (IIE), supporting the Comision Nacional para el Ahorro de Energia (CONAE) has prepared the preliminary project of the norm of energetic efficiency for pumping systems, specifically for the agricultural sector. This document has complied with the necessary formalities for the issue of a norm and is about to be published as a Mexican Official Norm of energetic efficiency. In this paper mention is made of the results in the analysis of the pumping systems in operation, the energy saving, as well as the economic evaluation that sustain the norm project, indicating besides the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) ha elaborado el anteproyecto de norma de eficiencia energetica en sistemas de bombeo, especificamente para el sector agricola. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, y esta proximo a publicarse como norma oficial mexicana de eficiencia energetica. En el presente articulo se mencionan los resultados del analisis de los sistemas de bombeo en operacion, los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicandose ademas el impacto ambiental que tendra la implantacion de la misma.

  10. Carbon Bonds and the saving of energy; Bonos de carbono y el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Ramirez, Alejandro [NovaEnergia (Mexico)

    2005-07-01

    This document deals with the development of the carbon bond project, the energy saving and the entry into force of the Kyoto Protocol at a world-wide level. In this project Mexico opts for a development model in which the economic growth brakes ties with the discharge of greenhouse effect gases and in which the progress does not mean more damages to our planet. [Spanish] Este documento trata sobre el desarrollo del proyecto de bonos de carbono, ahorro de energia y la entrada en vigor del Protocolo de Kyoto a nivel mundial, en el cual Mexico opta por un modelo de desarrollo en el que el crecimiento economico esta desvinculado de la emision de gases de efecto invernadero y en donde el progreso no signifique mas danos a nuestro planeta.

  11. Energy conservation in ice manufacturing; Ahorro de energia en la fabricacion de hielo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    This paper shows the results of the energy diagnosis study for ice manufacturing industries. The identified opportunities for conservation and efficient use of energy have allowed the reduction of the electric bill, modernizing at the same time, its installations and addressing inherent aspects of the use of energy producing items; in which the estimated investments are recovered in its major part in a period of a year, the goodness of the investments propitiate the growth and competitiveness required in these days. [Espanol] En este documento se exponen los resultados del estudio del diagnostico energetico para industrias productoras de hielo. Las oportunidades de ahorro y uso eficiente de energia identificadas, han permitido reducir la facturacion energetica, a la par de modernizar sus instalaciones y atender aspectos inherentes al uso de energeticos; en lo cual las inversiones estimadas se recuperan en su mayoria en un ano, las bondades de las inversiones propician un crecimiento y competitividad requerida en estos dias.

  12. Energy saving program in an operating potable water and sanitation organism; Programa de ahorro de energia en un organismo operador de agua potable y saneamiento

    Energy Technology Data Exchange (ETDEWEB)

    Flores Cruz, Juan Jose [Fideicomiso para el Ahorro de la Energia Electrica, (Mexico)

    2001-03-01

    For the achievement of the objectives it was decided to use, among others, the following strategies: Personnel training, increase of the efficiency of the electromechanical equipment, study of Comision Federal de Electricidad (CFE) tariffs, correction of low power factors, increase of load factors, operation automate, regulation of the operation times, preventive maintenance of the equipment, establishment of technical standards, rational and efficient use of air conditioning equipment and illumination. So that these actions were applied in an easy and opportune form, it was established that within the structure of the General Coordination of Foreign Municipalities, the Program of Energy Saving depended directly of the Technical Management of CFE. In this way, the recommendations are first put under consideration of high-level officers, and then are lowered to the operative departments. [Spanish] Para el logro de los objetivos se acordo utilizar, entre otras, las siguientes estrategias: capacitacion del personal; aumentar la eficiencia de los equipos electromecanicos; estudio de tarifas de la Comision Federal de Electricidad (CFE); correccion de bajos factores de potencia; aumento de los factores de carga; automatizar la operacion; regular de los tiempos de operacion; mantenimiento preventivo a los equipos; establecimiento de normas tecnicas; uso racional y eficiente de aire acondicionado e iluminacion. Para que estas acciones se aplicaran en forma agil y oportuna, se establecio que dentro de la estructura de la Coordinacion General de Municipios Foraneos, el Programa de Ahorro de Energia dependiera directamente de la Gerencia Tecnica de la CRE. De esta forma, las recomendaciones primero se someten a consideracion de los funcionarios de alto nivel, y luego bajan a los departamentos operativos.

  13. Compact fluorescent lamps, innovation for electricity saving; Lamparas fluorescentes compactas, innovacion para el ahorro de electricidad

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, Fernando [Fideicomiso para el Ahorro de Energia Electrica (Mexico); Camacho P, Wendolin E; Villalobos Alarcon, German [Phillips Lighting Mexico (Mexico)

    2007-01-15

    An extremely important resource is electricity because it has provided illumination for homes, buildings and cities in the absence of natural light. Therefore, the human being is considering to save this valuable resource by using sophisticated light bulbs. At the end of the 70's the compact fluorescent lamps appeared. In this article we can disclose the advantages and disadvantages of this technology, and how some years later of its invention, those lamps satisfied the client expectations, due to its cost, electricity saving, longer lifetime, use possibilities, and technological improvements. We can also know how Federal Electricity Commission (CFE) and The Trust Fund for Electric Energy Savings (FIDE) supported a project to favor these lamps to be in the Mexican market. [Spanish] La electricidad es un recurso de suma importancia porque ha contribuido a la iluminacion de casas, edificios y ciudades, ante la ausencia de luz natural, es por ello que se ha buscado ahorrar este recurso tan preciado con el uso de lamparas sofisticadas. Una tecnologia que aparecio a finales de los anos 70 fueron las lamparas fluorescentes compactas. En este articulo encontramos sus ventajas y desventajas, y como despues de algunos anos de su creacion comenzaron a llenar las expectativas del cliente gracias a su costo, ahorro de electricidad, mayor tiempo de vida, posibilidades de aplicacion y mejoras tecnologicas. Asi mismo podemos conocer, el proyecto que se hizo para que esta tecnologia entrara al mercado mexicano, con el apoyo de la Comision Federal de Electricidad (CFE) y del Fideicomiso para el Ahorro de Energia Electrica (FIDE).

  14. Energy saving and efficiency in building; Ahorro de energia y eficiencia en edificios

    Energy Technology Data Exchange (ETDEWEB)

    Perez Sanchez, Maria M. [Universidad Autonoma de Yucatan, Merida, Yucatan (Mexico); Pacheco Aguilar, Francisco [Comision Federal de Electricidad, (Mexico)

    2000-07-01

    High energy consumption is one of the serious problems in the world today. Newly, this question has taken on not only economic, but also social and ecological importance. In order to reduce the amount of fossil energy, energy diagnosis are one of the most useful tools for increasing the energy efficiency in buildings. In the Faculty of Engineering, dependency of the Universidad Autonoma de Yucatan, Mexico a program of energy diagnosis was developed under an ongoing project entitled energy savings program, which begun in 1996. This paper describes a methodology about diagnosis building energy consumption building shell and energy efficiency in a case study. No doubt future developments are likely to lead to changes in the estimates. We hope that, nevertheless, this study will contribute to increased energy efficiency in this Faculty. [Spanish] En el mundo actual, uno de los problemas mas serios que se tienen es el elevado consumo de energia, que no solamente representa un problema economico sino que tambien abarca aspectos de indole social y ecologica. Con el fin de reducir el alto costo de la energia fosil, el diagnostico de energia es una de las herramientas mas poderosas para promover la eficiencia de los edificios. En la Facultad de Ingenieria, dependencia de la Universidad Autonoma de Yucatan, Mexico se esta llevando a efecto un diagnostico energetico perteneciente al programa de ahorros de energia que comenzo en el ano de 1996. En este estudio se describe una metodologia de diagnostico de ahorro energetico y eficiencia energetica de la envolvente termica en un estudio del caso, aplicado a los edificios de la Facultad de Ingenieria (FIUADY).

  15. Saving of electrical energy in educative institutions; Ahorro de energia electrica en instituciones educativas

    Energy Technology Data Exchange (ETDEWEB)

    Castillo Medina, Gabino [Instituto Tecnologico y de Estudios Superiores de Monterrey Campus Estado de Mexico, (Mexico)

    2003-07-01

    The present work looks for integrating the actions of energy saving that can be applied in educative institutions, not concerning the level or size of the same ones. The actions go from questions of making aware the student population until those involved in the change in the operation, migration and implementation of technology. Without overlooking the formative aspect that the educative institutions have and the social commitment of these last ones. It is important that the saving measures have as mission to achieve a culture focussed to make efficient use of the resources, of energy as well as material. This culture must be born from the classrooms and must transform the way to be and act of the student community that will permeate itself with the society. Let us remember that actions are worth more than words, so the educative institutions must preach with the example. [Spanish] El presente trabajo busca integrar las acciones de ahorro de energia que pueden ser aplicadas en instituciones educativas, no importando el nivel o tamano de las mismas. Las acciones van desde cuestiones de concienciar a la poblacion estudiantil hasta las que involucran el cambio en la operacion, migracion e implementacion de tecnologia. Sin perder de vista el aspecto formativo que tienen las instituciones educativas y el compromiso social de estas ultimas. Es importante que las medidas de ahorro tengan como mision lograr una cultura enfocada a hacer uso eficiente de los recursos, tanto energeticos como materiales. Dicha cultura debe nacer desde las aulas y debe transformar la manera de ser y actuar, de la comunidad estudiantil que se permeara con la sociedad. Recordemos que las acciones valen mas que las palabras, asi que las instituciones educativas deben predicar con el ejemplo.

  16. México: la economía de los sectores institucionales, distribución del ingreso, ahorro y crecimiento

    Directory of Open Access Journals (Sweden)

    Roberto Michel Padilla

    2003-01-01

    Full Text Available A partir del análisis de las cuentas nacionales de México por sector institucional se descubre una relación de sustitución perfecta entre el ahorro externo y el ahorro interno. Cambios en la disponibilidad de ahorro externo generan, mediante diferentes mecanismos, variaciones en el mismo sentido en la participación de los salarios y los dividendos en el producto y en sus propensiones al consumo; y en sentido opuesto en el ahorro interno de las empresas. La relación de causalidad es clara; a mayor disponibilidad de ahorro externo mayor ingreso de los hogares y mayor consumo, no al revés. Mediante una reformulación del modelo de N. Kaldor, (1955, para incluir el ahorro externo y diferenciando las ganancias entre dividendos y ganancias retenidas, se formalizan y estiman, econométricamente, las relaciones entre los coeficientes de inversión, ahorro externo y dividendos por un lado y la distribución del ingreso entre salarios y ganancias por otro. Se resalta la importancia estratégica que la conducta económica de los dirigentes empresariales, manifiesta en las decisiones de inversión y en la propensión a distribuir las ganancias , ejerce sobre el crecimiento económico la distribución del ingreso, el consumo, el ahorro y la balanza de pagos. Hasta hoy, México se ha endeudado con el exterior para aumentar su consumo no para ampliar su planta productiva.

  17. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  18. Supercritical waste oxidation pump investigation

    Energy Technology Data Exchange (ETDEWEB)

    Thurston, G.; Garcia, K.

    1993-02-01

    This report investigates the pumping techniques and pumping equipment that would be appropriate for a 5,000 gallon per day supercritical water oxidation waste disposal facility. The pumps must boost water, waste, and additives from atmospheric pressure to approximately 27.6 MPa (4,000 psia). The required flow ranges from 10 gpm to less than 0.1 gpm. For the higher flows, many commercial piston pumps are available. These pumps have packing and check-valves that will require periodic maintenance; probably at 2 to 6 month intervals. Several commercial diaphragm pumps were also discovered that could pump the higher flow rates. Diaphragm pumps have the advantage of not requiring dynamic seals. For the lower flows associated with the waste and additive materials, commercial diaphragm pumps. are available. Difficult to pump materials that are sticky, radioactive, or contain solids, could be injected with an accumulator using an inert gas as the driving mechanism. The information presented in this report serves as a spring board for trade studies and the development of equipment specifications.

  19. 76 FR 34192 - Commercial and Industrial Pumps

    Science.gov (United States)

    2011-06-13

    ... Part 431 RIN 1904-AC54 Commercial and Industrial Pumps AGENCY: Office of Energy Efficiency and... commercial and industrial pumps. Additional input and suggestions relevant to this equipment are also welcome... submitting comments. E-mail: Pumps-RFI-2011-STD-0031@ee.doe.gov . Include EERE- 2011-BT-STD-0031 and/or...

  20. 46 CFR 132.120 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 132.120 Section 132.120 Shipping COAST GUARD....120 Fire pumps. (a) Except as provided by § 132.100(b) of this subpart, each vessel must be equipped with one self-priming power-driven fire pump capable of delivering a single stream of water from...

  1. 46 CFR 108.471 - Water pump.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam...

  2. Mining equipment manufacturers; 17th ed.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The report analyses and compares the financial ratios of mining equipment manufacturers in the United Kingdom. It includes companies who produce equipment for the mining industry such as cutting tools, drilling equipment, crushers, screens, centrifuges, tunnelling equipment, conveyors and other materials handling equipment, hydraulic equipment, filtration, pumping, and mixing equipment and ventilation equipment. The report presents business ratios analysing profitability, efficiency, liquidity, employee-based ratios and a series of figures on growth rate. Accounting data for the individual companies are given, together with principal ratios, areas of activity, names of directors and company secretary, trading address and holding companies.

  3. Mining equipment manufacturers. 13th edition

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    The report analyses and compares the financial ratios of mining equipment manufacturers in the United Kingdom. It includes companies who produce equipment for the mining industry such as cutting tools, drilling equipment, crushers, screens, centrifuges, tunnelling equipment, conveyors and other materials handling equipment, hydraulic equipment, filtration, pumping and mixing equipment and ventilation equipment. The report presents business ratios analysing profitability, efficiency, liquidity, employee-based ratios and a series of figures on growth rate. Accounting data for the individual companies are given, together with principal ratios, areas of activity, names of directors and company secretary, trading address and holding companies.

  4. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    of membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  5. 磁悬浮轴承技术在风机与泵类设备中的应用现状%Application Status of Magnetic Bearings in Fan and Pump Equipments

    Institute of Scientific and Technical Information of China (English)

    汤士明; 梅磊; 欧阳慧珉

    2013-01-01

    阐述了磁悬浮轴承的基本原理与优点,详细比较了与磁悬浮轴承技术相关的国内外最新研究动态,并研究了其在风机和泵类设备中的应用现状,最后通过分析磁悬浮轴承在空调应用中的技术性和经济性问题得出了其在空调风机、压缩机等设备上具有良好的市场应用前景的结论.%The basic principles of magnetic bearings and its advantages were explained.Its related new developments in home and board were compared in details,and the application status of magnetic bearings in fan and pump equipments was researched.The conclusion that magnetic bearings have a good prospect in air conditioning fans and compressors was gotten through the analysis of technical and economic problems of magnetic bearings application in air conditioning.

  6. Ahorro energético mediante estrategias de iluminación natural optimizadas

    Directory of Open Access Journals (Sweden)

    Puigdomènech Franquesa, Joan

    1986-04-01

    Full Text Available Electrical charges in buildings and specially in those of commercial use, can be diminished by means of natural lighting strategies. Taking the climate features of our country into consideration, it is necessary to prevent the inconveniences caused by an en erg y excess in summer, so solar Controls are needed. The only practical way to achieve the suitable balance between thermal and light needs, so as to get a monthly or annual energetic balance optimization, is to operate with the computer. A programme with such characteristics is described here. Its application gives important sarings in non renouvable energy savings.Mediante estrategias de iluminación natural es posible disminuir las cargas eléctricas de los edificios y en especial los de uso comercial. Dadas las características climáticas de nuestro país es necesario prever los inconvenientes de un exceso de energía en verano, para lo cual es preciso disponer de controles solares. Encontrar el correcto equilibrio entre las necesidades térmicas y lumínicas en base a la optimización del balance energético mensual o anual es únicamente factible mediante el uso del ordenador. Un programa que responde a estas características es descrito en el presente trabajo, obteniéndose con su aplicación importantes ahorros en el consumo de energías no renovables.

  7. Cálculo del ahorro de energía por menor fricción

    Directory of Open Access Journals (Sweden)

    Pedro Albarracín Aguillón

    2004-01-01

    Full Text Available En este artículo se expone como disminuir costos de operación (menor consumo de energía, costos de mantenimiento y pérdidas de producción de equipos, mediante el control de los diferentes fenómenos de la fricción en mecanismos lubricados. Para hacer esto posible es necesario conocer las condiciones criticas de trabajo de los mismos, a que tipo de lubricación corresponden, y que clase lubricante requiere, para así calcular los valores de los coeficientes de fricción de los lubricantes que se están empleando y compararlos con los de otros lubricantes que pueden dar lugar a ahorros de energía y mantenimiento. Además se presentan algunos ejemplos tomados de casos reales, que confirman que con una buena implementación de un programa de tribologia se obtienen resultados satisfactorios desde el punto de vista económico.

  8. Potential of energy saving with photovoltaic systems; Potencialidad de ahorro de energia con sistemas fotovoltaicos

    Energy Technology Data Exchange (ETDEWEB)

    Guzman S, Eusebio; Bratu S, Neagu [Universidad Autonoma Metropolitana, Mexico, D. F. (Mexico)

    1998-12-31

    This paper presents an approach on the application of photovoltaic systems in energy saving. The problem of the electric energy demand in the coming years is analyzed and its consequences on the environment and on the energy reserves of conventional sources. A model of the electric circuit equivalent to a photovoltaic cell illustrates the behavior of the photovoltaic cell in function of the climatological conditions. The former in order to show some of the limiting factors in this type of generator. Also, the evolution of the applications of the photovoltaic systems and its forecasting in the installed capacity in the next 20 years, is described. [Espanol] En este trabajo se presenta un enfoque de la aplicacion de los sistemas fotovoltaicos en el ahorro de energia. Se plantea el problema del crecimiento de la demanda energetica en los proximos anos y sus consecuencias sobre el medio ambiente y las reservas de energia por fuentes convencionales. Un modelo del circuito electrico equivalente de una celda fotovoltaica ilustra el comportamiento del generador fotovoltaico en funcion de las condiciones climatologicas. Lo anterior con el fin de mostrar algunas limitantes de este tipo de generador. Tambien se describe la evolucion de las aplicaciones de los sistemas fotovoltaicos y el pronostico de la potencia instalada en los proximos 20 anos.

  9. Remesas y Ahorro de los Migrantes Michoacanos radicados en EUA. Un Diagnóstico Preliminar

    Directory of Open Access Journals (Sweden)

    Jerjes Aguirre Ochoa

    2007-06-01

    Full Text Available El objetivo de este artículo es realizar un diagnostico del potencial productivo del ahorro migrante para el caso del estado de Michoacán. Los datos obtenidos muestran un perfil de Michoacano radicado en EUA con ingresos suficientes para enviar remesas familiares a México pero limitados para realizar inversiones mayores a 200 dólares mensuales en Michoacán. Dentro de esa limitación, de contar con capital, los michoacanos manifestaron una preferencia por invertir en México y específicamente en su comunidad de origen. La preferencia de inversión mas citada es la compra de una vivienda o reparación de la misma. Asimismo, la corrupción y la inseguridad son señaladas como obstáculos para la inversión en México. Finalmente, el alto porcentaje de migrantes indocumentados encontrados en la encuesta refleja los profundos impactos que una reforma migratoria en EUA puede tener en la dinámica económica del estado. La migración a EUA puede dejar de convertirse en la válvula de escape para la población michoacana que no encuentre oportunidades laborales en Michoacán sumiendo a la entidad en graves problemas económicos y sociales.

  10. Aeration equipment for small depths

    Science.gov (United States)

    Sluše, Jan; Pochylý, František

    2015-05-01

    Deficit of air in water causes complications with cyanobacteria mainly in the summer months. Cyanobacteria is a bacteria that produces poison called cyanotoxin. When the concentration of cyanobacteria increases, the phenomena "algal bloom" appears, which is very toxic and may kill all the organisms. This article describes new equipment for aeration of water in dams, ponds and reservoirs with small depth. This equipment is mobile and it is able to work without any human factor because its control is provided by a GPS module. The main part of this equipment consists of a floating pump which pumps water from the surface. Another important part of this equipment is an aerator where water and air are blended. Final aeration process runs in the nozzles which provide movement of all this equipment and aeration of the water. Simulations of the flow are solved by multiphase flow with diffusion in open source program called OpenFOAM. Results will be verified by an experiment.

  11. Energy efficiency standardizing in vertical pumps; Normalizacion de eficiencia energetica en bombas verticales

    Energy Technology Data Exchange (ETDEWEB)

    Acosta Torres, Rosa Aracely; Buendia Dominguez, Eduardo H. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The Instituto de Investigaciones Electricas (IIE) supporting the Comision Nacional para el Ahorro de Energia (CONAE) (National Commission for Energy Saving) developed the project of a standard on energy efficiency of vertical pumps, turbine type with external motor. This documents has fulfilled the necessary formalities for the issuing of a norm, being published the Mexican Official Norm (NOM-001-ENER-1995) on December 22, 1995. This article relates the results of the study for the elaboration of this norm, considering the energy saving, as well as the economic evaluation that supports the project of the norm, indicating also the environmental impact that its implantation will have. [Espanol] El Instituto de Investigaciones Electricas (IIE) apoyando a la Comision Nacional para el Ahorro de Energia (CONAE) elaboro el anteproyecto de norma de eficiencia energetica en bombas verticales tipo turbina con motor externo. Dicho documento ha cumplido con los tramites necesarios para la emision de una norma, habiendose publicado como Norma Oficial Mexicana (NOM-001-ENER-1995) el 22 de diciembre de 1995. En el presente articulo se mencionan los resultados del estudio para la realizacion de esta norma, considerando los ahorros energeticos, asi como la evaluacion economica que sustenta el proyecto de norma, indicando tambien el impacto ambiental que tendra su implantacion.

  12. 46 CFR 154.1005 - Equipment approval.

    Science.gov (United States)

    2010-10-01

    ... carried. (b) Each submerged cargo pump motor installation must be specially approved by the Commandant (CG... FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Electrical § 154.1005 Equipment approval. (a) Electrical equipment that is required to be intrinsically safe...

  13. Magnetocaloric pump

    Science.gov (United States)

    Brown, G. V.

    1973-01-01

    Very cold liquids and gases such as helium, neon, and nitrogen can be pumped by using magnetocaloric effect. Adiabatic magnetization and demagnetization are used to alternately heat and cool slug of pumped fluid contained in closed chamber.

  14. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  15. Una aproximación al análisis financiero de las cajas de ahorros andaluzas mediante el método multicriterio PROMETHEE

    Directory of Open Access Journals (Sweden)

    Asunción Zapata Reina.

    2000-01-01

    Full Text Available En este trabajo se hace un análisis económico y financiero de las cajas de ahorros andaluzas. Se abordan los diferentes aspectos (estructura patrimonial, estructura de costes, rentabilidad, productividad y solvencia de las seis cajas que configuran el sistema andaluz de cajas de ahorros, agrupadas en la confederación andaluza de cajas de ahorros, por medio de un conjunto de ratios. El gran número y la diversidad de ratios disponibles en el problema, generalmente en conflictos unos con otros, confiere a éste una dimensión multicriterio que analizamos con el método PROMETHEE. Procedimiento que permite sintetizar la información disponible sobre el conjunto estudiado.

  16. Energy saving in the sugar cane agroindustry; Ahorro de energia en la agroindustria azucarera canera

    Energy Technology Data Exchange (ETDEWEB)

    Zedillo Ponce de Leon, Luis [Grupo de paises Latinoamericanos y del Caribe exportadores de azucar (Mexico)

    1996-07-01

    The traditional sugar mill is inefficient from the energy point of view. Most of the sugar mills were designed to use all the available bagasse, due to the risk of spontaneous ignition and environmental pollution. Consequently, the steam generators, the turbines and other components were designed to work with low efficiencies. Each ton of sugar produced generates a power potential equivalent to four to six oil barrels (bagasse and residues). That is to say, a sugar mill is capable of producing 500 ton/day of sugar, equivalent to an oil well of 2000 to 3000 barrels/day and one thermoelectric power plant of 15,000 kW. Under this context an analysis is made of the sugar mills in Latin America and the Caribbean as one of the ways of increasing their efficiency and obtain great energy savings. As far as steam generation the appropriate use of energy is dictated by the boilers' efficiency. [Spanish] El ingenio azucarero tradicional es ineficiente desde el punto de vista energetico. La mayoria de los ingenios azucareros se disenaron para usar todo el bagazo disponible, debido al riesgo de ignicion espontanea y contaminacion. En consecuencia, los generadores de vapor, las turbinas y demas componentes fueron disenados para trabajar con bajas eficiencias. Cada tonelada de azucar producida genera una potencialidad energetica equivalente de cuatro a seis barriles de petroleo (bagazo y residuos). Es decir, un ingenio capaz de producir 500 ton/dia de azucar equivalente a un pozo de petroleo de 2000 a 3000 barriles/dia y una termoelectrica de 15000 kW. Bajo este contexto se hace un analisis del ingenio azucarero en Latinoamerica y el Caribe como una de las vias para incrementar su eficiencia y lograr grandes ahorros en la energia. En cuanto a generacion de vapor se refiere, el buen uso de la energia viene expresado por la eficiencia de las calderas.

  17. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  18. Modelo de gestión del riesgo crediticio en la cooperativa de ahorro y crédito Mirachina

    OpenAIRE

    2016-01-01

    1. Introducción. --2. Planteamiento de la Propuesta de Trabajo. --3. Marco Teórico. --4. Metodología. --5. Resultados La presente investigación tiene como objeto desarrollar un modelo de gestión del riesgo de crédito en la Cooperativa de Ahorro y Crédito Mirachina, para disminuir el índice de morosidad e incrementar los niveles de liquidez, alcanzando los parámetros exigidos por la entidad de control. Con esta mejora se reducirá a un dígito el riesgo de morosidad, mediante la aplicación de...

  19. Experiences of energy saving and co-generation projects; Experiencias de proyectos de ahorro de energia y cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Barajas, Alberto [Heat and Power Systems, S.A. de C.V., Mexico D.F. (Mexico)

    2005-07-01

    In this document are presented the successful projects of energy saving and co-generation that Heat and Power Systems, S.A. de C.V. has made in diverse industries. The investment recovery periods have been smaller to 18 months. The projects have been made for different companies within Mexican Republic. [Spanish] Se presentan los casos exitosos de proyectos de ahorro de energia y cogeneracion que Heat and Power Systems, S.A. de C.V. ha realizado en diversas industrias cuyo periodo de recuperacion de la inversion han sido menores a 18 meses. Los proyectos han sido realizados para distintas empresas dentro de la Republica Mexicana.

  20. Determinantes del isomorfismo institucional de las sociedades cooperativas de ahorro y préstamos en México

    OpenAIRE

    Graciela LARA GÓMEZ; Felipe A. Pérez Sosa

    2015-01-01

    El propósito del presente trabajo es establecer si las sociedades cooperativas de ahorro y préstamo se hacen isomorfas a la banca formal en México; debido a que tales entidades tradicionalmente han operado en un entorno de informalidad, pero últimamente han transitado hacia la formalización como consecuencia de las exigencias legales impuestas por entidades regulatorias. Para este fin, el presente estudio se llevó a cabo con una orientación metodológica mixta, en la que los resultados obtenid...

  1. Diseño bioclimático en Galicia : ahorro energético y confort

    OpenAIRE

    Pena Gayo, Katia

    2016-01-01

    El objeto de estudio de la presente disertación es la arquitectura bioclimática en Galicia, comunidad situada al noroeste de la península ibérica. La investigación surge fruto de una manera de entender la arquitectura como un elemento que debe relacionarse con el entorno en el que se ubica, aprovechando las condiciones del medio a su favor para generar ahorro energético y un mayor confort a sus ocupantes. El carácter limitado de recursos energéticos, junto con los problemas act...

  2. La Percepción Emocional del Dinero como Determinante de un Comportamiento de Ahorro o Endeudamiento

    Directory of Open Access Journals (Sweden)

    Mª Carmen Lozano Gutierrez

    2007-06-01

    Full Text Available En el presente artículo se realiza un análisis de afinidades en la percepción del dinero para las personas que ahorran o se endeudan, con la finalidad de establecer las consecuencias que en el comportamiento económico propio de cada grupo tienen las valoraciones subjetivas en relación al dinero. Las conclusiones a las que llegamos podrían servir para el desarrollo de estrategias de promoción del ahorro y contención del endeudamiento.

  3. La Percepción Emocional del Dinero como Determinante de un Comportamiento de Ahorro o Endeudamiento

    OpenAIRE

    Mª Carmen Lozano Gutierrez; Federico Fuentes Martín

    2007-01-01

    En el presente artículo se realiza un análisis de afinidades en la percepción del dinero para las personas que ahorran o se endeudan, con la finalidad de establecer las consecuencias que en el comportamiento económico propio de cada grupo tienen las valoraciones subjetivas en relación al dinero. Las conclusiones a las que llegamos podrían servir para el desarrollo de estrategias de promoción del ahorro y contención del endeudamiento.

  4. Aplicación de la Contabilidad de Costos en las Cajas Rurales de Ahorro y Crédito en el Perú, Arequipa - 2013

    OpenAIRE

    Pacheco Zegarra, Edward Víctor

    2017-01-01

    El presente trabajo de investigación busca determinar el grado de aplicación de la contabilidad de costos en las Cajas Rurales de Ahorro y Crédito en el Perú. ENUNCIADO “APLICACIÓN DE LA CONTABILIDAD DE COSTOS EN LA CAJAS RURALES DE AHORRO Y CRÉDITO EN EL PERÚ, AREQUIPA – 2013” La variable a investigar fue la aplicación de la contabilidad de costos cuyos indicadores son las generalidades de la aplicación de la contabilidad de costos, objetivos de la contabilidad de costos...

  5. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  6. Importance of the harmonics in the lighting systems for the electric energy saving; Importancia de las armonicas en el sistema de iluminacion para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Garibay Mendoza, V. [Lumisistemas, departamento de aseguramineto de calidad, Naucalpan (Mexico); Hernandez Bernal, J. M. [UNICORP, Mexico, D. F. (Mexico)

    1995-12-31

    In a lighting system the discharge lamps (fluorescent and high intensity discharge (HID)), ballast and controls are generating elements of harmonics. As a consequence of the tendency of saving energy, the use of electronic ballasts and controls that integrate dimmers, daylight and present sensors has increased in order to optimize the energy use. This paper presents the harmonics generation resulting from the fluorescent lamps operating different electronic ballasts as well as their electronic controls. Likewise, are also shown the effects caused by generation of harmonics components by the lighting system in the electric system that go from the voltage and current distortion, the presence of currents in the neutral conductor in balanced systems to the repercussions in the metering equipment such as watthour meters and the effects the lighting equipment suffer due to the presence of harmonics, such as the power factor decrease in ballasts that are of high power factor and the temperature increment in the magnetic type ballasts. [Espanol] Dentro de un sistema de iluminacion, las lamparas de descarga (fluorescentes y alta intensidad de descarga {sup H}ID{sup )}, balastros y los controles son elementos generadores de armonicas. A consecuencia de la tendencia al ahorro de energia se ha incrementado el uso de balastros electronicos y controles que integran atenuadores de luz (dimmers), sensores de luz natural y de presencia con el fin de optimizar el uso de la energia. Este trabajo presenta los resultados de generacion de armonicas para lamparas fluorescentes, operando diferentes balastros electronicos asi como con controles electronicos. Asi mismo son presentados los efectos causados por la generacion de componentes armonicas por el sistema de iluminacion dentro del sistema electrico que van desde la distorsion en voltaje y corriente, la presencia de corrientes dentro del conductor neutro en sistemas balanceados, asi como la repercusion en los equipos de medicion tales

  7. Strategy Guideline. HVAC Equipment Sizing

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2012-02-01

    This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, FL. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  8. Daylight-saving time: Consumption and demand saving and pollutants emission reduction; El cambio de horario de verano: Ahorros en consumo y demanda, y reduccion de contaminantes

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Gaudencio; Diaz, Rodrigo; Fiscal, Raul; Alquicira, Claudia; Martinez, Serafin; Maqueda, Martin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    This paper presents some of the saving obtained in demand and in fuels with the daylight-saving time, as well as the main aspects considered to make an evaluation of it. [Espanol] Se presentan los ahorros obtenidos en consumo, demanda y combustibles con el cambio de horario de verano, asi como los principales aspectos considerados para efectuar la evaluacion de los mismos.

  9. 电驱动和燃气驱动空气源热泵运行设备的分析%Exergy Analysis of the Operating Equipment of Electricity Engine-driven and Gas Engine-driven Air Source Heat Pump

    Institute of Scientific and Technical Information of China (English)

    史丽娜; 刘学来; 李永安

    2016-01-01

    对燃气驱动以及电驱动空气源热泵的制热过程进行了分析,得出各个运行设备的损、效率以及热力完善度。研究结果表明:空气源热泵的四大部件:蒸发器、压缩机、冷凝器、节流阀的损分别为0.372、2.722、1.219、0.322。燃气空气源热泵与电驱动空气源热泵均等效为一次能源时,系统的效率分别为22.52%、17.4%,可以看出燃气空气源热泵效率较电驱动空气源热泵高,燃气机热泵更经济节能。%The exergy analysis of the gas engine-driven and electricity engine-driven air source heat pump are made. , and the exergy loss, exergy efficiency and thermodynamic perfection degree of each equipment were obtained. The results show that the exergy losses of air source heat pump in the evaporator, compressor, condenser and throttle valve are 0. 372, 2. 722, 1. 219, 0. 322, respectively. When gas engine-driven and electricity engine-driven air source heat pump are all equivalent to primary en-ergy source,the exergy efficiency of the whole system were 22. 52%, 17. 4%,it can be seen that the exergy efficiency of the gas engine-driven air source heat pump is higher than that of the electricity engine-driven air source heat pump , and the gas engine-driven air source heat pump is more economical and energy saving.

  10. Ferroelectric Pump

    Science.gov (United States)

    Jalink, Antony, Jr. (Inventor); Hellbaum, Richard F. (Inventor); Rohrbach, Wayne W. (Inventor)

    2000-01-01

    A ferroelectric pump has one or more variable volume pumping chambers internal to a housing. Each chamber has at least one wall comprising a dome shaped internally prestressed ferroelectric actuator having a curvature and a dome height that varies with an electric voltage applied between an inside and outside surface of the actuator. A pumped medium flows into and out of each pumping chamber in response to displacement of the ferroelectric actuator. The ferroelectric actuator is mounted within each wall and isolates each ferroelectric actuator from the pumped medium, supplies a path for voltage to be applied to each ferroelectric actuator, and provides for positive containment of each ferroelectric actuator while allowing displacement of the entirety of each ferroelectric actuator in response to the applied voltage.

  11. 46 CFR 109.329 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 109.329 Section 109.329 Shipping COAST GUARD... of Safety Equipment § 109.329 Fire pumps. The master or person in charge shall insure that at least one of the fire pumps required in § 108.415 is ready for use on the fire main system at all times....

  12. Advanced heat pump research and development

    Science.gov (United States)

    Kuliasha, M. A.

    The Office of Building Energy Research and Development of the U.S. Department of Energy (DOE), has been funding R&D in advanced heat pumps and appliances since 1976. Much of that research has been managed for DOE by the Oak Ridge National Laboratory (ORNL). The objective of the Building Equipment Research (BER) program at ORNL has been to generate new concepts and develop a technology base for improving the energy efficiency and load characteristics of energy conversion equipment used in residential and commercial buildings. The research being pursued to achieve these objectives falls under three general areas: thermally activated heat pumps (TAHP), refrigeration systems, and building equipment systems. The TAHP work is concentrated on three technologies: (1) absorption heat pumps; (2) Stirling engine-driven heat pumps; and (3) internal combustion (IC) engine-driven heat pumps. Major project areas in refrigeration systems research include electric heat pumps, ground-coupled heat pumps, and refigerant mixtures. In the building equipment systems areas, project areas include advanced distribution systems, advanced insulation for appliances, and commercial building equipment.

  13. Dairy Equipment Lubrication

    Science.gov (United States)

    1978-01-01

    Lake To Lake Dairy Cooperative, Manitowoc, Wisconsin, operates four plants in Wisconsin for processing milk, butter and cheese products from its 1,300 member farms. The large co-op was able to realize substantial savings by using NASA information for improved efficiency in plant maintenance. Under contract to Marshall Space Flight Center, Midwest Research Institute compiled a handbook consolidating information about commercially available lubricants. The handbook details chemical and physical properties, applications, specifications, test procedures and test data for liquid and solid lubricants. Lake To Lake's plant engineer used the handbook to effect savings in maintenance labor and materials costs by reducing the number of lubricants used on certain equipment. Strict U.S. Department of Agriculture and Food and Drug Administration regulations preclude lubrication changes n production equipment, but the co-op's maintenance chief was able to eliminate seven types of lubricants for ancillary equipment, such as compressors and high pressure pumps. Handbook data enabled him to select comparable but les expensive lubricants in the materials consolidation process, and simplified lubrication schedules and procedures. The handbook is in continuing use as a reference source when a new item of equipment is purchased.

  14. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  15. Energy saving in illumination using sensorial presence devices; Ahorro de energia en iluminacion utilizando sensores de presencia

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Eslava, Alejandro [Universidad Nacional Autonoma de Mexico (Mexico)

    2001-03-01

    This is an analysis and evaluation of electrical energy saving that a system of illumination controlled by presence sensors provides in an enclosure with low transit within the Universidad Nacional Autonoma de Mexico (UNAM) that is one of the libraries of the Institute of Anthropological Investigations. The data on which the analysis is sustained and the results deducted come from a time counter located at the site. [Spanish] Este es un analisis y evaluacion de los ahorros de energia electrica que suministra un sistema de iluminacion controlado por sensores de presencia en un recinto con bajo transito dentro de la Universidad Nacional Autonoma de Mexico (UNAM) que es una de las bibliotecas del Instituto de Investigaciones Antropologicas. Los datos de donde se sustenta el analisis y se deducen los resultados provienen de un contador de tiempo de uso localizado en el sitio.

  16. Study on Drying Technology of Wild Erythroculter Ilishaeformis Using Solar Assisited Heat Pump Equipment%野生白鱼热泵太阳能组合干燥设备及工艺研究

    Institute of Scientific and Technical Information of China (English)

    吴鹏辉; 付捷; 稂晓嘉; 邱瑜

    2016-01-01

    野生白鱼的初始含水率在75%以上且热敏性较高,烘干所需时间较长。为了降低干燥过程的能耗,达到削减成本、节能减排的目的,采用热泵太阳能组合干燥的方法,以干燥总能耗为响应值,以影响野生白鱼干燥能耗的3个主要因素(干燥温度、环境湿度、太阳能系统能耗)为响应值,设计了三因素三水平响应面分析试验,通过Design Expert 8.0统计分析软件,对数据进行响应面优化。在干燥风速为2m/s,太阳能系统的供热时间为10小时的条件下,确定野生白鱼干燥的最佳工艺为:干燥温度为41.02℃,太阳能系统的循环风机功率为0.85kW,环境湿度为20%,此时干燥总能耗的最小值为43.8975 kW·h 。%The initial moisture of wild erythroculter ilishaeformis is generally higher than 75%,so the dr-ying time was needed.The purposes of this study is to reduce the energy consumption of the drying process,cut costs and save the energy by using a solar assisited heat pump equipment.In this study,the technology of dr-ying wild erythroculter ilishaeformis was optimized by response surface method.Taking the total energy con-sumption as response,the model was using response surface analysis of three main effect factors(drying temper-ature,humidity and circulation energy)at three levels.The data were analysis tested by Design Expert 8.0 sta-tistical analysis software.Under the conditions of the drying wind speed 2m/s and the heating time of solar sys-tems for 10 hours,the best drying technology of wild erythroculter ilishaeformis:the drying temperature was 41.02 ℃,circulating energy consumption was 0.85kW ·h,and the humidity was 20%.In this case,the mini-mum value of the total energy consumption of the drying was 43.8975kW·h.

  17. Estimated saving potential and efficient use of energy in air conditioning by means of the solar protection; Potencial estimado de ahorro y uso eficiente de energia en aires acondicionados mediante la proteccion solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-07-01

    In here it is presented the analysis of the impact of the solar gains through the transparent parts of a prototype house of social interest, located in a dry warm climate. This analysis was made to determine the gains through windows for the summer time and under the following conditions: without outside solar protections, with the use of eaves, solar breakers and finally with the use of both systems of solar protection. The results were compared to obtain the considered potential of energy saving in cooling equipment, that could be obtained in future houses to build. [Spanish] Se presenta el analisis del impacto de las ganancias solares a traves de las partes transparentes de un prototipo de vivienda de interes social, ubicado en un clima calido seco. Dicho analisis se realizo para determinar las ganancias a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin protecciones solares exteriores, con el empleo de aleros, con quiebrasoles y finalmente con el empleo de ambos sistemas de proteccion solar. Se compararon los resultados para obtener el potencial estimado de ahorro de energia en equipo de enfriamiento, que se tendria en las futuras viviendas por construir.

  18. Penis Pump

    Science.gov (United States)

    ... claim that they can be used to increase penis size, but there's no evidence that they work for ... circumstances, using a penis pump might help your penis maintain its natural size and shape after prostate surgery or if you ...

  19. Fault detection in the electrical equipment of the artificial system, used for the oil production in marine platforms; Deteccion de fallas en los equipos electricos del sistema artificial, utilizado para la produccion de petroleo en plataformas marinas

    Energy Technology Data Exchange (ETDEWEB)

    Vargas H, Vicente; Rosales S, Inocente [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Pimentel M, Jorge [Petroleos Mexicanos (Mexico)

    2007-07-01

    At present, PEMEX is using new artificial pumping systems for the production of oil, specifically the Electro Centrifugal Pumping system (ECP). Nevertheless, during the operation of the (ECP) system problems by the failure of their electrical components have appeared, mainly of the equipment installed within the well. The faults have resulted in an increased cost for the diminution in the production and the maintenance cost of the remedial work. The maintenance personnel have procedures to perform verification tests of the conditions of the bottom electrical equipment. But, in the case of an electrical failure of the equipment, its location cannot be determined, since they are installed at 3,600 m from the production wellhead. In accordance with the former, the Instituto de Investigaciones Electricas proposed the application of the reflectometry technique in the time domain, to complement the maintenance procedures. This technique is a very useful diagnosis tool of the electrical equipment, which helps in the decision making of the maneuvers of preventive and corrective maintenance to be followed, with the consequent saving of resources. [Spanish] Actualmente, PEMEX esta utilizando nuevos sistemas artificiales de bombeo para la produccion de petroleo, en especifico el Sistema de Bombeo Electrocentrifugo (BEC). Sin embargo, durante la operacion del Sistema BEC se han presentado problemas por la falla de sus componentes electricos, sobre todo del equipo instalado dentro del pozo. Las fallas han resultado con un costo elevado por la disminucion en la produccion y por los trabajos de mantenimiento correctivo. El personal de mantenimiento cuenta con procedimientos para realizar pruebas de verificacion del estado de los equipos electricos de fondo. Pero, en el caso de una falla electrica de los equipos, no se puede determinar su ubicacion, dado que se instalan a 3,600 m del cabezal del pozo de produccion. De acuerdo con lo anterior, el Instituto de Investigaciones

  20. 46 CFR 154.534 - Cargo pumps and cargo compressors.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pumps and cargo compressors. 154.534 Section 154.534 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Equipment Cargo and Process Piping Systems § 154.534 Cargo pumps and cargo compressors. Cargo pumps...

  1. 33 CFR 183.566 - Fuel pumps: Placement.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel pumps: Placement. 183.566...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.566 Fuel pumps: Placement. Each fuel pump must be on the engine it serves or within 12 inches of the engine, unless it is...

  2. 46 CFR 105.35-5 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 105.35-5 Section 105.35-5 Shipping COAST... VESSELS DISPENSING PETROLEUM PRODUCTS Fire Extinguishing Equipment § 105.35-5 Fire pumps. (a) All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons...

  3. Mining equipment manufacturers: an industry sector analysis; 14th edition

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    The report analyses and compares the financial ratios of mining equipment manufacturers in the United Kingdom. It includes companies who produce equipment for the mining industry such as cutting tools, drilling equipment, crushers, screens, centrifuges, tunnelling equipment, conveyors and other materials handling equipment, hydraulic equipment, filtration, pumping and mixing equipment and ventilation equipment. The report presents business ratios analysing profitability, efficiency, liquidity, employee-based ratios and a series of figures on growth rate. Accounting data for the individual companies are given, together with principal ratios, areas of activity, names of directors and company secretary, trading address and holding companies.

  4. Electric energy saving and its impact in the mining industry; El ahorro de energia electrica y su impacto en la industria minera

    Energy Technology Data Exchange (ETDEWEB)

    Urteaga Dufour, Jose Antonio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    In this paper are shown the most important results of the energy diagnosis performed in some representative industries of the mining industry, where opportunity areas were detected in electric energy saving, starting from those measures that do not require investment up to the ones that require medium investment, recoverable in less than two years terms as a maximum and with electric energy saving ranging from 10% to 25%. [Espanol] En este trabajo, se presentan los resultados mas importantes, obtenidos en el diagnostico energetico realizado en algunas empresas representativas de la rama de la mineria, en donde se detectaron areas de oportunidad de ahorro de energia electrica que van desde aquellas medidas que no requieren inversiones hasta las que requieren medianas inversiones, recuperables en menos de dos anos como maximo y con ahorros de energia que van desde un 10% hasta un 25%.

  5. Modelo de Gestión Gerencial para disminuir los riesgos en la cooperativa de Ahorro y Crédito Tulcán.

    OpenAIRE

    Mora Grijalva, Ney Fernando

    2012-01-01

    Realizar un diagnóstico de la gestión en la Cooperativa de Ahorro y Crédito “Tulcán”, con los diferentes responsables de las áreas y de las oficinas operativas, a fin de determinar el papel de los procesos de participación, de la interpretación de los indicadores financieros y gestión enfocados a mitigar los diferentes riesgos. En el presente estudio: Modelo de Gestión Gerencial para disminuir los riesgos en la Cooperativa de Ahorro y Crédito ¿Tulcán¿ qué es una entidad financiera r...

  6. Investigación industrial sobre ahorro de energía en la fabricación de nuevos cementos compuestos españoles

    Directory of Open Access Journals (Sweden)

    Puig, J.

    1981-09-01

    Full Text Available Not available

    Se exponen en este trabajo los resultados de un estudio consistente en la preparación de varios cementos nuevos, en diversas fábricas de diferentes zonas del país, basada en la utilización de materiales de adición, tanto activos como fillers calizos, con objeto de contribuir al ahorro energético en la fabricación de cemento. Los nuevos cementos fabricados se comparan con los producidos en la actualidad y se llega a la conclusión de que muchos de ellos permitirán sustanciales ahorros de fuel-oil, sin merma sensible, en la mayoría de los casos —y con mejora en otros— de la calidad y del comportamiento de los cementos nuevos.

  7. Integral programs of energy conservation (exergy) in the petroleum industry; Programas integrales de ahorro de energia (exergia) en la industria petrolera

    Energy Technology Data Exchange (ETDEWEB)

    Rivero Rodriguez, R. [Instituto Mexicano del Petroleo (IMP), Mexico, D. F. (Mexico)

    1995-12-31

    This paper presents some of the fundamental issues related to energy conservation programs in general and to the petroleum industry in particular with the purpose of integrating them both, that is, considering not only the energy issues, but also the ecological and economical aspects. This is achieved by using the two fundamental laws of thermodynamics (the science that studies energy, its characteristics, and its transformations) through the use of the exergy concept, which is a measure of the energy quality and of its withdrawal with respect to the environment. The origins of the present-day technologies, regarding energy conservation, the short, medium and long term general strategies and the implementation stages of the integral programs of energy conservation are presented, and it concludes with a series of general policies aimed at making the energy conservation programs more congruent with the maintenance of a sustainable development. [Espanol] En este trabajo se presentan algunos aspectos fundamentales relacionados con los programas de ahorro de energia en general, y en la industria petrolera en particular, con objeto de lograr que los mismos sean integrales, es decir que consideren no solo los aspectos puramente energeticos, sino tambien los aspectos ecologicos y economicos. Esto se logra utilizando conjuntamente las dos leyes fundamentales de la termodinamica (la ciencia que estudia la energia, sus caracteristicas y sus transformaciones), mediante la utilizacion del concepto de exergia, que es una medida de la calidad de la energia y de su alejamiento con respecto al medio ambiente. Se presentan los origenes de las tendencias tecnologicas actuales en materia de ahorro de energia, las estrategias generales a corto, mediano y largo plazos y las etapas en la implementacion de programas integrales de ahorro de energia, para concluir con una serie de politicas generales tendientes a lograr que los programas de ahorro de energia sean congruentes con el

  8. Ahorre Energia: Consejos sobre el ahorro de dinero y energia en el hogar (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2014-09-01

    Learn how to save money with Energy Saver: Tips on Saving Money & Energy at Home, from the U.S. Department of Energy. The Energy Saver guide will help you reduce your monthly energy costs and live more efficiently. This guide takes you through the systems and appliances that consume the most energy in your home, and provides solutions to cut costs for you while saving the environment. The Energy Saver guide also includes transportation tips to help you save money at the pump.

  9. Ahorro de agua y materia prima en los procesos de pelambre y curtido del cuero mediante precipitación y recirculación de aguas

    Directory of Open Access Journals (Sweden)

    SANDRA AGUDELO A.

    2007-01-01

    Full Text Available El principio del proceso de recuperación de cromo, consiste en precipitar el cromo contenido en el licor residual como hidróxido utilizando un álcali; este precipitado se separa por sedimentación y se disuelve nuevamente con ácido sulfúrico. De los resultados obtenidos, se observaron porcentajes de remoción superiores al 99%. Con la recirculación directa de aguas de pelambre fue posible obtener ahorros de agua del 64% y ahorros en materia prima del 32 %, además, con una adecuada selección del tamizador es posible recircular el agua un número máximo de tres veces, sin afectar la calidad del producto final. Así mismo, se comprobó la viabilidad de la recirculación directa de aguas de curtido, con ahorros de materia prima del 17%. Con medidas de este tipo, prácticas y fáciles de implementar, la industria del curtido del cuero podría disminuir considerablemente la contaminación, operar de una forma mas segura y con mayor eficiencia de producción.

  10. Análisis de ahorro energético en iluminación LED industrial: Un estudio de caso

    Directory of Open Access Journals (Sweden)

    Ana Serrano-Tierz

    2015-01-01

    Full Text Available El presente estudio muestra el ahorro económico y las ventajas medioambientales que supone la iluminación industrial con tecnología LED. Se ha planteado un estudio de caso en el que luminarias de halogenuros metálicos han sido sustituidas por luminarias LED. Para validar la sustitución de luminarias con halogenuros metálicos de 400W por LED de 200W, se han efectuado las simulaciones luminotécnicas y mediciones de campo mediante luxómetro. Los resultados obtenidos indican que ambas luminarias son equiparables obteniendo un importante ahorro energético cercano al 50%. Esta investigación demuestra que la tecnología LED ofrece soluciones de iluminación de alto rendimiento que optimizan el ahorro energético reduciendo a su vez costes de mantenimiento con un coste total de propiedad significativamente menor, incrementando la esperanza de vida útil de las luminarias. Desde el punto de vista medioambiental supone una importante reducción en emisiones de CO2 y eliminación de residuos tóxicos como el mercurio.

  11. Portable Heat Pump Testing Device

    Directory of Open Access Journals (Sweden)

    Kłosowiak R.

    2015-08-01

    Full Text Available The aim of this paper is to present the design and working principle of a portable testing device for heat pumps in the energy recirculation system. The presented test stand can be used for any refrigerating/reverse flow cycle device to calculate the device energy balance. The equipment is made of two portable containers of the capacity of 250 liters to simulate the air heat source and ground heat source with a system of temperature stabilization, compressor heat pump of the coefficient of performance (COP of = 4.3, a failsafe system and a control and measurement system.

  12. Pumps; Pumpen

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, H. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft; Hellriegel, E. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft; Pfitzner, G. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft

    1994-11-01

    The technical features of commercial pump types are described with regard to their technical, energy-related and economic parameters, and characteristic data are presented in the form of data sheets. This is to provide a basis for a comparative assessment of different technologies and technical variants. The chapter `System specifications` describes the various fields of application of pumps and the resulting specific requirements. The design and function of the different pump types are described in `Technical description`. `System and plant description dscribes the design and adaptation of pumps, i.e. the adaptation of the plant data to the system requirements. `Data compilation` provides a survey of the types and systematics of the compiled data as well as a decision aid for selecting the pumps best suited to the various applications. The `Data sheet` section describes the structure and handling of the data sheets as well as the data contained therein. The data sheets are contained in the apapendix of this report. The section `General analysis` compares typical technical, energy-related and economic characteristics of the different pump types. This is to enable a rough comparison of pump types and to facilitate decisions. The chapter `Example` illustrates the use of the data sheets by means of a selected example. (orig./GL) [Deutsch] Die vorliegende Arbeit hat zum Ziel, Technik seriengefertigter und marktgaengiger Pumpen in typisierter Form hinsichtlich ihrer technischen, energetischen und wirtschaftlichen Parameter zu beschreiben und ihre charakteristischen Kennwerte in Datenblaettern abzubilden. Damit wird ein grundlegendes Instrument fuer die vergleichende Beurteilung unterschiedlicher Techniken bzw. Technikvarianten hinsichtlich energetischer und wirtschaftlicher Kriterien geschaffen. Im Abschnitt `Systemanforderungen` erfolgt die Beschreibung der einzelnen Anwendungsbereiche fuer Pumpen mit den speziellen daraus resultierenden Anforderungen. Der Aufbau und

  13. Las puzolanas y el ahorro energético en los materiales de construcción

    Directory of Open Access Journals (Sweden)

    Soria Santamaría, Francisco

    1983-09-01

    Full Text Available This discussion commences with some general comments on the energy crisis and its impact on the cement industry, with the corresponding coal reconversion problems. Three factors are highlighted where saving has been centered: technological process, raw materials and finished product, emphasizing the interest of latter which includes incorporating active additions in Portland cement. A quick review then follows about pozzolanas, their origin, definitions and classification. Their chemical composition is underlined, and the concept of pozzolanic activity is described. Later on, pozzolanic cements, their most significant properties and the advantages of using pozzolana are explained. After a lengthy description about possible applications of pozzolanas and pozzolanic cements, the conclusion reviews current trends in international standards for such cements and possible evolution in consumption of additions by the year 2000, with a view to saving more energy, without impairing the essential properties of the cement.

    Comienza esta exposición con unas consideraciones generales sobre la crisis energética y su impacto en la industria cementera, con los correspondientes problemas de reconversión al carbón. Se mencionan los tres aspectos en que se ha centrado el ahorro energético: proceso tecnológico, materias primas y producto acabado, destacando el interés de este último que incluye la incorporación de adiciones activas al cemento portland. Se hace a continuación un rápido comentario sobre puzolanas, su origen, definiciones y clasificación. Se destaca la composición química de las mismas y se desarrolla el concepto de actividad puzolánica. Más tarde se hace una exposición sobre cementos puzolánicos, sus propiedades más destacadas y las ventajas que supone el empleo de la puzolana. Tras una exposición amplia de las posibles aplicaciones de las puzolanas y cementos puzolánicos, se concluye comentando las tendencias

  14. National potential of saving of electricity in domestic refrigeration; Potencial nacional de ahorro de electricidad en refrigeracion domestica

    Energy Technology Data Exchange (ETDEWEB)

    Arroyo C, Fernando [Universidad Nacional Autonoma de Mexico (Mexico); Ambriz G, Juan Jose; Romero P, Hernando [Universidad Autonoma Metropolitana, (Mexico)

    2003-07-01

    In the present paper the evaluation of the potential of saving of electrical energy in Mexico is presented, by means of the substitution of old refrigerators of low efficiency by modern high efficiency ones. This potential is very ample, since the replacement of the old models by new follows a very slow curve, if the economic difficulties of the Mexican families are considered and that, on the other hand, the technology of the domestic refrigerators is so reliable that they have a very long life and they are not easily rejected. In field work have been found refrigerators operating with ages of more than 30 years and still 40. In Mexico, it is estimated that the refrigeration is responsible for around 29% of the of electricity consumption in homes settled in tempered climate and of 14 % in those of warm climate in which air conditioning is used. The proposal of this work is the organization of a governmental program of accelerated substitution of refrigerators that helps to acquire an efficient refrigerator and to reject the old ones. The results indicate that if a total renovation of the park of domestic refrigerators is made, the saving of electrical energy would reach the 5.2 TWh/a which represents the 44.5% of the total consumption of 11.7 TWh in a year. [Spanish] En el presente trabajo se presenta la evaluacion del potencial de ahorro de energia electrica en Mexico, mediante la substitucion de refrigeradores antiguos de baja eficiencia por modernos de alta eficiencia. Este potencial es muy amplio, ya que el reemplazo de los modelos viejos por nuevos sigue una curva muy lenta, si se consideran las dificultades economicas de las familias mexicanas y que, por otro lado, la tecnologia de los refrigeradores domesticos es tan confiable que tienen una vida muy larga y no se desechan facilmente. En trabajos de campo se han encontrado refrigeradores operando con edades de mas de 30 anos y aun 40. En Mexico, se estima que la refrigeracion es responsable de alrededor del

  15. Cost-benefit of energy saving in bioclimatic designs; Costo-beneficio del ahorro de energia en los disenos bioclimatios

    Energy Technology Data Exchange (ETDEWEB)

    Lopez P, J. Manuel A. [Doble dos soluciones de Negocios (Mexico); Morillon G, David; Rdriguez V, Luis [Universidad Autonoma de Mexico (Mexico)

    2001-06-01

    Tools and criteria for Cost-Benefit Analysis (ACB) of energy saving in bioclimatic designs (DB) are presented, for which a reference project is established. Based on the traditional design of air conditioning of a building and with the support of this one, the estimation of costs and benefits of the same building is made; but with passive systems. The tools used consider related resources such as time and money. Criteria are used such as: Present value (VP), Equivalent Annual Cost (EAC) and the Cost of the conserved Energy (CEC). The costs related to the construction, maintenance and operation of the design are taken into consideration. The differences between the design of reference and the Bioclimatic Design, established from the application of these criteria, allow evaluating the economic margin as far as operation and maintenance. Finally, the cost of the conserved energy of the bioclimatic measures is evaluated as an initiative for energy saving and calculates the present value from them in all of the period of useful life of the bioclimatic design. [Spanish] Se presentan herramientas y criterios para el analisis Costo-Beneficio (ACB) del ahorro de energia en los disenos bioclimaticos (DB), para lo cual se establece un proyecto de referencia. Basado en el diseno tradicional de la climatizacion de un edificio y con apoyo en este, se realiza la estimacion de costos y beneficios del mismo edificio; pero con sistema pasivos. Las herramientas usadas consideran recursos relacionados como son tiempo y dinero. Se usan criterios tales como: Valor Presente (VP), Costo Anual Equivalente (CAE) y el Costo de la Energia conservada (CEC). Se toman en consideracion los costos relacionados con la construccion, mantenimiento y operacion del diseno. Las diferencias entre el diseno de referencia y el Diseno Bioclimatico, establecidas a partir de la aplicacion de estos criterios, permiten evaluar el margen economico en cuanto a la operacion y el mantenimiento. Finalmente, se

  16. Projects of electrical energy saving in Costa Rica; Proyectos de ahorro de energia electrica en Costa Rica

    Energy Technology Data Exchange (ETDEWEB)

    Henry Chinchilla [Compania Nacional de Luz y Fuerza, S.A., San Jose (Costa Rica)

    1999-07-01

    Costa Rica, located in Central America, is a highly electrified country, more of the 93.6% of the population, has access to the electricity, and its load curve presents two important demand peaks, one of them near noon and another one at sundown, additionally, the growth of this service is important, reason why it has been oriented to the establishment of actions focussed to the better use of the energy, in special of the electricity. The following notes are intended to show briefly the origin of the actions oriented to the energy saving, identifying the main projects that marked an important track in the national development in this sense, as well as a sample of some of the projects which have permitted to maintain throughout the last decade of this century a permanent attitude on the promotion and education of the saving and handling of the energy demand, specially of electricity, of such a way as to a suitable contribution is achieved towards the industrial competitiveness, human comfort and environmental protection. [Spanish] Costa Rica, ubicado en la America Central, es un pais altamente electrificado, mas del 93.6% de la poblacion, tiene acceso a la electricidad, y su curva de carga presenta dos importantes picos de demanda uno cercano al medio dia y otro al ocultarse el sol, junto a ello el crecimiento este servicio es importante, por lo que se ha abocado a establecer acciones que se orientan al mejor uso de la energia, en especial de la electricidad. En las siguientes notas se trata de mostrar en forma breve el origen de las acciones orientadas al ahorro de energia, identificando los principales proyectos que marcaron una huella importante en el rumbo nacional en este sentido, asi como una muestra de algunos de los proyectos que han permitido mantener a lo largo de la ultima decada de este siglo una permanente actitud de la promocion y ensenanza del ahorro y manejo de la demanda de energia, en especial de la electricidad, de tal forma que se logre con ello

  17. Types of Breast Pumps

    Science.gov (United States)

    ... Devices Consumer Products Breast Pumps Types of Breast Pumps Share Tweet Linkedin Pin it More sharing options ... used for feeding a baby. Types of Breast Pumps There are three basic types of breast pumps: ...

  18. The relation between preventive maintenance and energy saving, planning and production control; La relacion entre el mantenimiento preventivo y el ahorro de energia planeacion y control de la produccion

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Cazarez, Mario [Coorporacion de ingenieros en aire acondicionado y mantenimiento en general (Mexico)

    2003-07-01

    In this paper the importance that the preventive maintenance has as an important ingredient of the internal policies of the companies for the promotion of the energy saving is discussed. It considers that the department of planning and production control must take into account very seriously the importance of programmed preventive maintenance in order to maintain the continuity of the production process and with this eliminate the bottle necks that adversely affect it and consequently the the company's image before the clients, besides contributing positively the promotion of energy saving. The faults that stop the production process inflict losses of income and adversely affect the yield of the company, in addition, they increase the production cost or the plant expenses associated to the repair of the damaged equipment, in the worst of the cases, important penalties will have to be paid for the delayed delivery of the product to the client. By keeping the correct operation of the equipment, increasing its availability and assuring that all the safeties of these operate correctly we will be contributing to the optimal operation of the enterprise system and avoiding the additional consumption of energy associated to the failure of an equipment and interruption of the production line. The preventive maintenance also promotes, the order and the cleanliness, the safety and hygiene in the work centers and the protection to the environment. Once the prevention has won the battle to the correction, one enters the field of diagnosis, handling the service periods in an optimal way in benefit of the production line. In this stage it can be spoken of entering the application of Total Productive Maintenance. [Spanish] En este trabajo se discute la importancia que tiene el mantenimiento preventivo como un ingrediente importante de las politicas internas de las empresas para la promocion del ahorro de energia. Considera que el departamento de planeacion y control de la

  19. Laser Technology and Equipment

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    5W CW Diode-Pumped Solid-State Green Laser;QCW Diode-Pumped Solid-State Green Laser;High Beam Quality Diode-Pumped In-Frared Laser;High Beam Quality Diode-Pumped Infrared Laser;QCW Diode-Pumped Solid-State UV Laser;

  20. Pressure surges generated by the polling out of pumping equipment in conduction by pressure. Application of a real case; Transitorios hidraulicos generados por arranque de equipos de bombeo en conducciones a presion. Aplicacion a un caso real

    Energy Technology Data Exchange (ETDEWEB)

    Carmona-Perales, L. G.; Carmona-Perales, R. B. [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2000-12-01

    Water closed conduits are commonly designed with special attention paid to pressure surges due to pumping failures. In some particular cases, such at the Rio Yaque-Guaymas water pipeline system, pressure surges due to pumping start up are as high and dangerous as those produced by pumping failures. New subroutines were thus developed and included in the Closed Conduit Flow Transient Model developed by the Instituto de Ingenieria of the Universidad Nacional Autonoma de Mexico. This paper presents the mathematical model and its numerical solution using the Method of Characteristics and the Newton-Raphson Method. With the new modelling system it is possible to evaluate the pressure fluctuation time series due to start up at any pumping system. Using this new system a reliable explanation of bursts at the Rio Yaqui-Guaymas pipeline system could be set forth. [Spanish] Al disenar conducciones a presion, es comun que se presente especial atencion a los transitorios hidraulicos generados por paros de emergencia de los equipos de bombeo. En el acueducto rio Yaqui-Guaymas, Sonora, Mexico, los transitorios generados al poner en marcha los equipos de bombeo son tan importantes como los productos por disparo de bombas. En el Instituto de Ingenieria de la UNAM, se desarrollo e implanto en un programa de simulacion de transitorios hidraulicos en tuberias a presion una subrutina para simular el arranque de equipos de bombeo. El modelo matematico esta formado por el conjunto de ecuaciones dinamica y de continuidad, asi como la condicion de frontera que describe el arranque de las bombas. Se rescriben las ecuaciones dinamicas y de continuidad, con el metodo de las caracteristicas y se plantea un sistema de ecuaciones no lineales, el cual se resuelve con el metodo de Newton-Raphson. La simulacion del arranque de las bombas del acueducto en estudio, arroja valores de las cargas piezom ricas maximas y minimas mayores que la resistencia de la tuberia y menores que la topografia del

  1. Pressure surge generated by start up of pumping equipment in pipes to pressure. Application to a real case; Transitorios hidraulicos generados por arranque de equipo de bombeo en conducciones a presion. Aplicacion a un caso real

    Energy Technology Data Exchange (ETDEWEB)

    Carmona Paredes, L.G.; Carmona Paredes, R.B. [Instituto de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2000-12-01

    Water closed conduits are commonly designed with special attention paid to pressure surges due to pumping failures. In some particular cases, such at the Rio Yaqui-Guaymas water pipeline system, pressure surges due to pumping start ups are as high and dangerous as those produced by pumping failures. New subroutines were thus developed and included in the Closed Conduit Flow Transient Model developed by the Instituto de Ingenieria of the Universidad Nacional Autonoma de Mexico. This paper presents the mathematical model and its numerical solution using the Method of Characteristics and the Newton-Raphson Method. With the new modeling system it is possible to evaluate the pressure fluctuation time series due to start up at any pumping system. Using this new system a reliable explanation of bursts at the Rio Yaqui-Guaymas system could be set forth. [Spanish] Al disenar conducciones a presion, es comun que se preste especial atencion a los transitorios hidraulicos generados por paros de emergencia de los equipos de bombeo. En el acueducto rio Yaqui-Guaymas, Sonora, Mexico, los transitorios generados al poner en marcha los equipos de bombeo son tan importantes como los producidos por disparo de bombas. En el Instituto de Ingenieria de la UNAM, se desarrollo e implanto en su programa de simulacion de transitorios hidraulicos en tuberias a presion una subrutina para simular el arranque de equipos de bombeo. El modelo matematico esta formado por el conjunto de ecuaciones dinamica y de continuidad, asi como la condicion de frontera que describe el arranque de las bombas. Se reescriben las ecuaciones dinamica y de continuidad, con el metodo de las caracteristicas y se plantea un sistema de ecuaciones no lineales, el cual se resuelve con el metodo de las caracteristicas y se plantea un sistema de ecuaciones no lineales, el cual se resuelve con el metodo de newton-raphson. La simulacion del arranque de las bombas del acueducto en estudio, arroja valores de las cargas

  2. Pioneering Heat Pump Project

    Energy Technology Data Exchange (ETDEWEB)

    Aschliman, Dave [Indiana Inst. of Technology, Inc., Fort Wayne, IN (United States); Lubbehusen, Mike [Indiana Inst. of Technology, Inc., Fort Wayne, IN (United States)

    2015-06-30

    This project was initiated at a time when ground coupled heat pump systems in this region were limited in size and quantity. There were economic pressures with costs for natural gas and electric utilities that had many organizations considering ground coupled heat pumps; The research has added to the understanding of how ground temperatures fluctuate seasonally and how this affects the performance and operation of the heat pumps. This was done by using a series of temperature sensors buried within the middle of one of the vertical bore fields with sensors located at various depths below grade. Trending of the data showed that there is a lag in ground temperature with respect to air temperatures in the shoulder months, however as full cooling and heating season arrives, the heat rejection and heat extraction from the ground has a significant effect on the ground temps; Additionally it is better understood that while a large community geothermal bore field serving multiple buildings does provide a convenient central plant to use, it introduces complexity of not being able to easily model and predict how each building will contribute to the loads in real time. Additional controllers and programming were added to provide more insight into this real time load profile and allow for intelligent shedding of load via a dry cooler during cool nights in lieu of rejecting to the ground loop. This serves as a means to ‘condition’ the ground loop and mitigate thermal creep of the field, as is typically observed; and It has been observed when compared to traditional heating and cooling equipment, there is still a cost premium to use ground source heat pumps that is driven mostly by the cost for vertical bore holes. Horizontal loop systems are less costly to install, but do not perform as well in this climate zone for heating mode

  3. Oportunidad de ahorro energético en sistema para la climatización de unidades quirúrgicas

    Directory of Open Access Journals (Sweden)

    Jorge Alberto Mora Aguilera

    2010-01-01

    Full Text Available Se presentó una valoración del autor acerca de la oportunidad de ahorro de energía eléctrica en el sistema para la climatización del Hospital Pediátrico de Holguín a partir de la recuperación de energía del volumen de aire que se expulsa al exterior en los quirófanos. En los resultados del trabajo se describió el procedimiento empleado para la cuantificación de la incidencia del volumen de aire para la ventilación de los quirófanos en el deterioro del consumo energético del sistema para la climatización y se enunció una propuesta que logra ahorrar energía eléctrica en el mismo mediante la elevación de su eficiencia energética sin comprometer los requerimientos de limpieza del aire que se maneja.

  4. Hydraulic speed variators for electrical energy saving; Variadores de velocidad hidraulicos para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Mexico, D. F. (Mexico)

    1999-07-01

    This paper shows the characteristics and applications of the hydraulic speed variators, where because of the conditions of the industrial processes it is necessary to vary the operation parameters, obtaining therefore an energy saving besides improving the control of these processes. In addition, the technical and economic evaluation is presented of a project of the Mazatlan Fossil Power Plant, in which it is intended to invest in the installation of a hydraulic speed variator connected to the forced draft fan of unit number three, which operates with an induction motor of 1,865 kW (2,500 H.P.), with a Voltage of 4,180 V at 1,180 rpm. [Spanish] El presente trabajo muestra las caracteristicas y aplicaciones de los variadores de velocidad hidraulicos, donde por las condiciones de los procesos industriales sea necesario variar los parametros de operacion, obteniendose asi un ahorro de energia ademas de mejorar el control de dichos procesos. Se presenta ademas la evaluacion tecnica y economica de un proyecto de la Planta Termoelectrica Mazatlan, en donde se pretende invertir en la instalacion de un variador de velocidad hidraulico acoplado al ventilador de tiro forzado de la unidad numero tres, el cual opera con un motor de induccion de 1,865 kW (2,500 H.P.), con un voltaje de 4,180 V y una velocidad de 1,180 rpm.

  5. CAJAS DE AHORROS: UN MODELO DE COMPROMISO CON LA SOCIEDAD / SAVINGS BANKS AND SOCIETY: A MODEL OF COMMITMENT TO SOCIETY

    Directory of Open Access Journals (Sweden)

    Antoni SEGUÍ ALCARAZ

    2012-01-01

    Full Text Available Las entidades de crédito tienen cada vez mayor interés en las cuestiones sociales, como reflejo de un compromiso empresarial para satisfacer la demanda de la sociedad, en general, funcionando de una forma eficiente a medio plazo. El trabajo de campo se realizó a través de una encuesta contestada por 57 entidades de crédito españolas. En las Cajas de ahorros por lo que se refiere al tipo de inversión, se observan correlaciones significativas positivas entre el porcentaje del presupuesto destinado a inversiones en la comunidad y en proyectos medioambientales. Por lo tanto, vemos que cuantas más inversiones se realizan en la comunidad, mayor cantidad se destina a proyectos medioambientales. Por el contrario, se observa una relación negativa entre el porcentaje del presupuesto destinado a inversiones para la comunidad y la materialización de las aportaciones en metálico / The field work was conducted through a questionnaire answered by 57 Spanish institutions. In savings banks as regards the type of investment, there are significant positive correlations between the percentage of the budget for investment in community and environmental projects. Therefore, we see that the more investments are made in the community, the greater amount is allocated to environmental projects. On the contrary, there is a negative relationship between the percentage of the budget for investment in the community and the realization of cash contributions.

  6. Edificio de oficinas del Monte de Piedad y Caja de Ahorros de Sevilla-España

    Directory of Open Access Journals (Sweden)

    Población Knappe, Eleuterio

    1981-03-01

    Full Text Available Architect The essential feature of the new building of the Pawnshop and Savings Bank in Seville, built on a site in an «L» form and affected in the course of the planning and building by successive changes of Ordenances, its attempt to harmonize with the surrounding architecture, respecting its traditional characteristics. The building, which has seven stories on a slope and two basements, broadcasts its different private and public missions by the volumes, forms and different exterior treatments, presenting particular attention to its functionality in accordance with the initial programme proposed by the organisation.

    La característica esencial de la nueva sede del Monte de Piedad y Caja de Ahorros de Sevilla, levantada sobre un solar en forma de «L» y afectada en el transcurso del proyecto y construcción por sucesivos cambios de Ordenanzas, armoniza con la arquitectura circundante, respetando sus características tradicionales. La edificación, de siete plantas sobre rasante y dos sótanos, patentiza su distinta misión privada y de cara al público a través de los volúmenes, formas y diferentes tratamientos exteriores, presentando una especial atención a su funcionalidad de acuerdo con el programa inicial planteado por la entidad.

  7. Potential of bioclimatic architecture for energy saving in buildings; Potencial de la arquitectura bioclimatica para ahorro de energia en edificios

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Chavez, Jose Roberto [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1994-12-31

    The design and construction of current buildings has been characterized, most of all, in the last 30 years, for the lack of consideration in the design process of aspects that nowadays represent a fundamental importance. These aspects are related to energy conservation and environmental protection, with man as the main center of attention for the optimum satisfaction of its physiological as well as psychological needs. In this paper are presented the causes for the lack of consideration of the mentioned aspects and guidelines to follow are set forth for their integration in the design process. Also the architecture potential with a bioclimatic approach is analyzed, for energy saving in buildings. [Espanol] El diseno y construccion de edificios contemporaneos se ha caracterizado, sobre todo en los ultimos treinta anos, por la falta de consideracion en el proceso de diseno, de aspectos que hoy en dia revisten una importancia primordial. Estos aspectos se relacionan con la preservacion de la energia y del medio ambiente, teniendo al hombre como principal centro de atencion, para la satisfaccion optima de sus necesidades, tanto fisiologicas como psicologicas. En este trabajo, se presentan las causas de la falta de consideracion de los aspectos antes citados y se plantean las pautas a seguir para su integracion en el proceso de diseno. Asi mismo, se analiza el potencial de la arquitectura con un enfoque bioclimatico, para ahorro de energia en los edificios.

  8. Energy saving by the use of polystyrene in construction; Ahorro de energia por la utilizacion de poliestireno en la construccion

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel, Raul [Polioles S. A. de C. V., Mexico, D. F. (Mexico)

    1992-12-31

    In the past last years, the building industry has been faced with requirements in the rational energy use and environmental preservation. The polystyrene foam is a material that for more than forty years has demonstrated its attributes all over the world in its application in the construction industry as well as in the packing and crating industries, becoming a synonym of economic construction in regard to energy saving and a synonym also of a rational and safe packing. In this paper a short description is made of the manufacturing process of the expandable polystyrene foam, its properties and applications in the construction industry. [Espanol] En los ultimos anos, la industria de la construccion se ha enfrentado a exigencias en el uso racional de la energia y en la preservacion del medio ambiente. La espuma de poliestireno expansible es un material que por mas de cuarenta anos, ha demostrado sus cualidades a nivel mundial en su aplicacion tanto en la industria de la construccion como en la del empaque y embalaje, llegando a convertirse en sinonimo de una construccion economica en cuanto a ahorro de energia y sinonimo tambien de un embalaje racional y seguro. En este trabajo se hace una breve descripcion del proceso de fabricacion de la espuma de poliestireno expandible, sus propiedades y aplicaciones dentro de la industria de la construccion.

  9. 浅析市政泵站电气设备的管理与维护%Analysis on the Management and Maintenance of Electrical Equipment for Municipal Pumping Station

    Institute of Scientific and Technical Information of China (English)

    杨锐

    2015-01-01

    文章通过对南京市主城区市政管养泵站管理体制及电气设备维护要求的具体剖析,总结了市政管养泵站电气设备管理维护的一些方法经验,具有参考价值和实际意义.%Through the concrete analysis on the management system and the maintenance requirements of the management system and electrical equipment maintenance of the main city of Nanjing city , this paper summarizes some methods of the management and maintenance of electrical equipment in the municipal management ,and has reference value and practical significance.

  10. 7 CFR 2902.28 - Stationary equipment hydraulic fluids.

    Science.gov (United States)

    2010-01-01

    ... formulated for use in stationary hydraulic equipment systems that have various mechanical parts, such as cylinders, pumps, valves, pistons, and gears, that are used for the transmission of power (and also...

  11. Development of liquid nitrogen Centrifugal Pump

    Energy Technology Data Exchange (ETDEWEB)

    Abe, M; Sagiyama, R; Tsuchiya, H [Institute for Solid State Physics, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581 (Japan); Takayama, T [Institute for Molecular Science, National Institutes of Natural Sciences, 38 Nishigo-Naka, Myodaiji, Okazaki, Aichi 444-8585 (Japan); Torii, Y [OMNIX, 1-15-3 Nishishinjuku, Shinjuku, Tokyo, 160-0023 (Japan); Nakamura, M [YN Nakamura Ltd, 3-9-25 Ohjima, Koto, Tokyo, 136-0072 (Japan); Hoshino, Y [JECC TORISHA Co. Ltd, 2-8-52 Yoshinodai, Kawagoe-shi, Saitama, 350-0833 (Japan); Odashima, Y [Department of Basic Sciences, University of Tokyo, 3-8-1 Komaba, Meguro, Tokyo 153-8902 (Japan)], E-mail: mirei@issp.u-tokyo.ac.jp

    2009-02-01

    Usually liquid nitrogen (LN{sub 2}) transfer from a container to a laboratory equipment takes place by applying pressure to the container to push out liquid or pouring liquid into the cryostat directly by lifting the container. In order to overcome inconvenience of pressuring or lifting containers, we have been developing the Liquid Nitrogen Centrifugal Pump of a small electric turbine pump. Significant advantages that both reducing time to fill LN{sub 2}and controlling the flow rate of liquid into the cryostat are obtained by introducing this pump. We have achieved the lift of about 800mm with the vessel's opening diameter of 28mm.

  12. Unitary water-to-air heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-10-01

    Performance and cost functions for nine unitary water-to-air heat pumps ranging in nominal size from /sup 1///sub 2/ to 26 tons are presented in mathematical form for easy use in heat pump computer simulations. COPs at nominal water source temperature of 60/sup 0/F range from 2.5 to 3.4 during the heating cycle; during the cooling cycle EERs range from 8.33 to 9.09 with 85/sup 0/F entering water source temperatures. The COP and EER values do not include water source pumping power or any energy requirements associated with a central heat source and heat rejection equipment.

  13. Drilling equipment

    Energy Technology Data Exchange (ETDEWEB)

    Voyevodin, Yu.M.; Kholosha, Ye.G.; Leshchenko, A.G.; Timchenko, A.I.

    1979-01-10

    The invention refers to units designed for extracting minerals by mechanical action on the face by a cutting tool. There is a known drills which includes a pulse device which contains a combustion chamber, cylinder, piston-percussion tool and cutting tool. The combustion chamber and the sub-piston cavity of the cylinder are connected by a channel in which there is a distributor. Its shortcoming is the fact that the pulse device does not guarantee the necessary motion of the actuating mechanism for its velocity and frequency of the shocks on the cutting tool. This reduces the efficiency of the operation and limits the area of application. The purpose of the proposed invention is to improve productivity of the device. This is achieved because the head of the drill is equipped with a 2-piston pulse device which contains 2-combustion chambers, 2 working cylinders, 2 piston percussion instruments, a rod with gas-conducting and connecting channels for interconnection of the sub-piston cavities and combustion chambers of both cylinders. The spent gases of one cylinder are used for closing the combustion chamber of the second cylinder.

  14. Pumps, valves and fittings:the life cycle cost of the equipments, war-horse of the AFPR (association francaise des pompes et de la robinetterie); Pompes et robinetterie: le cout du cycle de vie des equipements, cheval de bataille de l'AFPR

    Energy Technology Data Exchange (ETDEWEB)

    Deboutte, G.

    2005-07-01

    The cheaper product is not necessarily the less expensive. Here is, in summary, the concept of the life cycle cost of the equipments, according to the AFPR, which sees here an answer to the Asiatic competition and a mean to optimize the energy consumptions. (O.M.)

  15. Audel water well pumps and systems mini-ref

    CERN Document Server

    Woodson, Roger D

    2011-01-01

    Introducing an Audel ""Mini-Ref"" for tradespeople working on water well pumps and pumping systems Water well pumps are used everywhere, with installations numbering in the millions. It's hard to believe that no one has written a small field book that covers these pieces of equipment. Finally, here's a great handy guide is for anyone who needs to know how these pumps work, how to troubleshoot problems unique to this type of piping system, and how to make common repairs for both above ground and submersible pumps. It contains vital and specific references applicable to a wide range of

  16. El capital social y su tratamiento en las entidades en las entidades de ahorro y crédito popular sobre la base de la normativa contable internacional

    Directory of Open Access Journals (Sweden)

    Luis Carlos Gámez Adame

    2013-03-01

    Full Text Available Las Entidades de Ahorro y Crédito Popular (Cooperativas constituyen un segmento importante dentro de los servicios financieros que se prestan en diferentes países y que han tenido un desarrollo vertiginoso al satisfacer demandas y necesidades de numerosas masas poblacionales.Se presentan algunas consideraciones asociadas al tratamiento del capital social en estas entidades sobre la base de la normatividad contable internacional vigente y donde a criterio de los autores existen una serie de incongruencias a las que hay que darles solución.

  17. Cost-Benefit of the energy saving in the bioclimatic designs; Costo-Beneficio del ahorro de energia en los disenos bioclimaticos

    Energy Technology Data Exchange (ETDEWEB)

    Lopez P, J. Manuel A. [Doble Dos Soluciones de Negocios, S.A. de C.V., Mexico, D.F. (Mexico); Morillon G, David; Rodriguez V, Luis [Instituto de Ingenieria de la UNAM, Mexico, D.F. (Mexico)

    1999-07-01

    Tools and criteria for the Cost-Benefit analysis from the energy saving in bioclimatic designs (BD) are presented, for which, a reference project is established and the costs and benefits of energy saving in BD with base in that project are evaluated. A case study is presented taking as reference the traditional design of the air conditioning of a building and with this base the estimation of cost-benefit of the same building is made, but with passive systems. The tools used are those that allow to consider related resources such as time and money; in that sense, are used criteria such as: Present value (PV), Equivalent Annual Cost (EAC) and the Cost of the Conserved Energy (CCE). The costs related to the construction, maintenance and operation of the design are taken into account. The differences between the reference design and the BD, established from the application of these criteria, allow to evaluate the economic margin of the BD as far as operation and maintenance is concerned. Finally the CCE of the bioclimatic measures is evaluated as an initiative of energy saving and the present value is calculated of the energy saving in the entire useful life of a bioclimatic design. [Spanish] Se presentan herramientas y criterios para el analisis Costo-Beneficio del ahorro de energia en disenos bioclimaticos (DB), para lo cual, se establece un proyecto de referencia y se evaluan los costos y beneficios del ahorro de energia en DB con base en ese proyecto. Se presenta el estudio de un caso tomando como referencia el dise tradicional de la climatizacion de un edificio y con base en este, se realiza la estimacion de costos y beneficios del mismo edificio, pero con sistemas pasivos. Las herramientas usadas, son aquellas que permiten considerar recursos relacionados como son tiempo y dinero; en ese sentido, se usan criterios como: Valor Presente (VP), Costo Anual Equivalente (CAE) y el Costo de la Energia Conservada (CEC). Se toman en consideracion los costos relacionados

  18. Evaluation of energy saving in large scale projects in domestic lighting; Evaluacion del ahorro de energia en proyectos de gran escala en alumbrado domestico

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Adrian [Comision Federal de Electricidad, Mexico, D.F. (Mexico)

    2001-07-01

    The present work shows the methodology and the necessary parameters are indicated to evaluate the energy saving and the reduction of power demand obtained, by the large scale projects of substitution of incandescent lamps by compact, circular fluorescent and globe type lamps in the domestic sector. [Spanish] El presente trabajo muestra la metodologia y se indican los parametros necesarios para evaluar el ahorro de energia y reduccion de la demanda de potencia obtenidos, por los proyectos de gran escala de sustitucion de focos incandescentes por lamparas fluorescentes compactas, circulares y tipo globo en el sector domestico.

  19. Diseño inmotico para ahorro energético, seguridad y control de instalaciones para el nuevo edificio de la fiec

    OpenAIRE

    Cobos Franco, Ma. Jose; Loayza Intriago, Andrea A.; Garay Contreras, Francisco; Leyton, Edgar

    2009-01-01

    Este proyecto tiene como propósito asegurar a los usuarios de la edificación un aumento del confort, de la seguridad, del ahorro energético y de las facilidades de comunicación mediante la automatización de la gestión y la información de la misma. Se explican los principios teóricos empleados en este proyecto. Se detallan conceptos básicos de Edificio Inteligente así como la definición y diferencias entre los diferentes conceptos que encierra la Domótica. Además se realiza un estudio ...

  20. 牧草种子热泵辅助型太阳能储热干燥设备设计与试验%Design and Experiment of Heat Pump Assisted Solar Energy Heat-storage Drying Equipment for Herbage Seed

    Institute of Scientific and Technical Information of China (English)

    王全喜; 王德成; 杜建强; 翟改霞

    2012-01-01

    Aiming at herbage seed drying equipment problems of power consumption, air discharge and solar energy application, a drying mode was proposed. Basis heating was supplied by thermal-stored solar energy, and air charge was dehumidified and reused by heat pump. Main working parts, such as thermal collector, thermal storage and heat pump, and whole drying machine were designed. Using movable design idea, thermal collector was controllable and whole machine was placed safely. Performance test results showed that handling capacity reached to 161 kg/h, power handling capacity achieved to 8. 4 kg/ ( kW · h) , the drying capacity reached to 3 367 kg · % /h, and dry strength achieved to 6. 7 kg/ ( m3 · h). The power consumption ration of solar PCM heat-storage drying, solar energy and heat pump teamwork drying, heat-pump drying and electricity power drying was 0. 9:1.0:1.2:1. 5.%针对牧草种子干燥设备在能耗、排放和太阳能使用等方面存在的问题,提出了太阳能储热供热为主,尾气由热泵除湿后回收使用为辅的节能零排放干燥模式,完成了集热、储热和热泵等主要工作部件以及整机的结构设计,用移动式设计实现了太阳能集热可控和整机安全贮存.试验结果表明:处理量161 kg/h,度电处理量8.4 kg/(kW·h),干燥能力3 367 kg·%/h,干燥强度6.7 kg/(m3 ·h);太阳能相变储热干燥、太阳能一热泵联合干燥、热泵干燥和电加热干燥4种供热干燥模式的耗电量之比是0.9:1.0:1.2:1.5.

  1. Evolution of service company equipment for cementing and well stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.E.

    1976-01-01

    Equipment for performing the 2 vital services of cementing and stimulation of oil and gas wells have gone through many major advancements. They can be categorized into equipment for handling and blending of products to be pumped and equipment for delivery of mixed fluids into the well at a variety of rate and pressure conditions. To provide some chronological pattern to the unique developments, the following breakdown for discussion is outlined: (1) cement pumping equipment; (2) cement blending equipment; (3) stimulation pumping equipment; and (4) frac fluid blending equipment. While these categories represent the visible equipment found on location, it must be remembered that service companies have provided advancement in base facility equipment around the world which has made it possible to increase the quality and number of products which can be delivered quickly to any well location. Products in use have increased from less than 12 in the 1930s to nearly 1,000 in the 1970s. Each must be carefully prepared, transported, blended, and pumped to satisfy very unique well conditions.

  2. Analysis and Treatment of Mechanical Seals Leaks for Rubber Equipment Solvent Pumps%橡胶装置溶剂泵机械密封泄漏原因分析与处理

    Institute of Scientific and Technical Information of China (English)

    吕广红; 黄崇林; 黎景宏

    2011-01-01

    分析橡胶装置溶剂泵机械密封泄的原因,结果表明,溶剂泵机械密封泄漏的原因是密封端面比压过大造成静环急剧磨损而引起的.将原来的非平衡型改造成平衡型的机械密封后,密封端面的密封性能和磨耗性都能满足要求,使用寿命有了明显提高.%The leak reasons of the mechanical seals for solvent pumps was analyzed,the results indicated that the leak reason was that the seal face specific pressure was too high which lead to the abrasion of stator ring suddenly. After transforming the original non-balanced mechanical seals to the balanced mechanical seal,the seal character and the abradability of seal face could satisfy the request, service life was improved obviously.

  3. Energy saving with speed variators; Ahorro de energia con variadores de velocidad

    Energy Technology Data Exchange (ETDEWEB)

    Dolores Anguiano, Ramses; Dolores Vazquez, Raul [Cementos Cruz Azul, Hidalgo (Mexico)

    2005-07-01

    The cement plant Cruz Azul S.C.L. is located in the center of the Mexican republic at 70 km north of the capital. Nowadays the Direction of Cementos Cruz Azul has implemented measures allowing to reduce their production costs. The optimization department found a great area of opportunity at the ventilators of the plant. The ventilators are used in different stages of the process and their flow was normally controlled by means of dampers -due to the high costs of the initial investment and that of maintenance of the speed variation technology which in its majority used direct current equipments. In this case it existed the possibility of making a successful application in two large ventilators, with motors of 1000 HP fed in medium tension (4160 v) in our calcination unit Num. 8. This document shows the development of this project from its initial analysis to its application and results. [Spanish] La planta de cemento Cruz Azul S.C.L. se encuentra localizada en el centro de la republica mexicana a 70 Km al norte de la capital. En estos momentos la direccion de cementos Cruz Azul ha implementado medidas que permitan reducir sus costos de produccion. El departamento de optimizacion encontro una gran area de oportunidad en los ventiladores de la planta. Los ventiladores son utilizados en distintas etapas del proceso y normalmente su flujo era controlado por medio de mamparas, debido a los altos costos como inversion inicial y de mantenimiento de la tecnologia de variacion de velocidad que en su mayoria utilizaba equipos de corriente directa. Para nuestro caso existia la posibilidad de realizar una aplicacion exitosa en dos ventiladores grandes, con motores de 1000 HP alimentados en media tension (4160 v), en nuestra unidad de calcinacion Num. 8. Este documento muestra el desarrollo de este proyecto desde su analisis inicial hasta su aplicacion y resultados.

  4. Aquatic Equipment Information.

    Science.gov (United States)

    Sova, Ruth

    Equipment usually used in water exercise programs is designed for variety, intensity, and program necessity. This guide discusses aquatic equipment under the following headings: (1) equipment design; (2) equipment principles; (3) precautions and contraindications; (4) population contraindications; and (5) choosing equipment. Equipment is used…

  5. Fuzzy Activity Based Life Cycle Costing For Repairable Equipment

    Directory of Open Access Journals (Sweden)

    Mulubrhan Freselam

    2016-01-01

    Full Text Available Life-cycle cost (LCC is the much known method used for decision making that considers all costs in the life of a system or equipment. Predicting LCCs is fraught with potential errors, owing to the uncertainty in future events, future costs, interest rates, and even hidden costs. These uncertainties have a direct impact on the decision making. Activity based LCC is used to identify the activities and cost drivers in acquisition, operation and maintenance phase. This activity based LCC is integrated with fuzzy set theory and interval mathematics to model these uncertainties. Day–Stout–Warren (DSW algorithm and the vertex method are then used to evaluate competing alternatives. A case of two pumps (Pump A and Pump B are taken and their LCC is analysed using the developed model. The equivalent annual cost of Pump B is greater than Pump A, which leads the decision maker to choose Pump A over Pump B.

  6. LMFBR with booster pump in pumping loop

    Science.gov (United States)

    Rubinstein, H.J.

    1975-10-14

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.

  7. Proceedings of the 20 National seminar on the rational use of energy and exposition of equipment and services. [Selected Papers]; 20. Seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This document contains the proceedings of the 20 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociaciacion de Tenicos y Profesionistas en Aplicacion Energetica (ATPAE), in Mexico, D.F, from the 15 to the 19 of November of 1999. This Seminar covered subjects such as: Energy saving in the power sector, power efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in constructions, transport, utilization of renewable energies, and energy and the environment. [Spanish] Este documento contiene la memoria tecnica del 20 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F., del 15 al 19 de noviembre de 1999. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables, y energia y ambiente.

  8. Proceedings of the 21 National seminar on the rational use of energy and exposition of equipment and services. [Selected Papers]; 21 Seminario nacional sobre el uso racional del a energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This document contains the proceedings of the 21 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), in Mexico, D.F., from the 14 to the 16 of March of 2001. This Seminar covered subjects such as: Energy saving in the power sector, power efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in constructions, transport, utilization of renewable energies and the environment. [Spanish] Este documento contiene la memoria tecnica del 21 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F., del 14 al 16 de marzo de 2001. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables y ambiente.

  9. 19. National seminar on the rational use of energy and exposition of equipment and services. Transactions. [Selected Papers]; 19. Seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This document contains the technical proceedings of the 19 national seminar on the rational use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Pofesionistas en Aplicacion Energetica (ATPAE) (Association of Technicians and Professionals on Energy Application) conducted in Mexico City on September 21-25, 1998. This seminar encompassed subjects such as: energy saving in the energy sector, energy efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in buildings, transportation, non-renewable energy utilization and environmental impact and eco-energies. [Espanol] Este documento contiene la memoria tecnica del 19 seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F, los dias 21-25 de septiembre de 1998. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables, e impacto ambiental y eco-energias.

  10. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  11. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device.

  12. 33 CFR 157.11 - Pumping, piping and discharge arrangements.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Pumping, piping and discharge... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.11 Pumping, piping and discharge arrangements. (a) Each tank vessel must have a fixed piping system for transferring oily mixtures from...

  13. 46 CFR 76.25-15 - Pumps and water supply.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Pumps and water supply. 76.25-15 Section 76.25-15... EQUIPMENT Automatic Sprinkling System, Details § 76.25-15 Pumps and water supply. (a) An automatically... water from the two highest fire hose outlets in a manner similar to that described in §...

  14. Overall control and monitoring systems for pumped storage plants

    Energy Technology Data Exchange (ETDEWEB)

    Stepinski, B.; Cvetko, H.

    1982-01-01

    Experience and technical innovations in power plant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.

  15. Electric power saving potential due to domestic refrigerators replacement; Potencial de ahorro de energia electrica por el reemplazo de refrigeradores domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de Energia Electrica (Mexico)]. E-mail: jose.peralta@cfe.gob.mx

    2006-04-15

    In Mexico the second most used electrical appliance is: refrigerator. Owing to its use, it would be a promising option for electric power saving. In Guadalajara, Reynosa and Tampico it was performed a study with the aim of launching a project to replace the old refrigerators with new ones which are more effective and less expensive. Since the refrigerators cost and the electrical invoicing saving, the electric appliance change is profitable. To expect with this replacement more than eight million of refrigerators manufactured before 1997 will be changed. [Spanish] El refrigerador es el segundo electrodomestico mas utilizado a nivel nacional, esto permite que debido a su uso sea una opcion prometedora para el ahorro de energia electrica. Se hizo un estudio en Guadalajara, Reynosa y Tampico con el fin de lanzar un proyecto para sustituir los refrigeradores viejos por unos nuevos que sean mas eficaces y menos costosos. Por el costo de los refrigeradores y el ahorro en la facturacion electrica, el cambio de electrodomestico es rentable, de esta manera se espera que los mas de ocho millones de refrigeradores fabricados antes de 1997 que existen en el pais sean cambiados.

  16. Dry vacuum pumps

    Science.gov (United States)

    Sibuet, R.

    2008-05-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R&D/industries, merits over conventional pumps and future growth scope will be discussed.

  17. 太阳能热泵联合干燥农产品的实验研究%Experimental Study of Solar and Heat Pump Equipment Combined Drying of Agricultural Products

    Institute of Scientific and Technical Information of China (English)

    李锐; 王瑞霞; 江燕涛

    2016-01-01

    Solar drying is method of drying agricultural products more energy-efficient method,but due to solar discontinuity and instability,using a single solar drying will greatly reduce the drying efficiency,and due to the di-versity of agricultural product material and properties of complexity,the single solar drying is difficult to meet the quality requirements,is often used in combination with other energy.This paper from the new energy development by starting with the perspective of energy-saving emission reduction,Zhanjiang area farmers to meet needs of drying agricultural products,design a kind of solar energy and heat pump combined drying device based on,drying experi-ments were conducted using the device of white radish,verify the the device the drying effect,the results show that the drying device as the economy running reliable,and has good agricultural products drying effect.%太阳能干燥是农产品干燥方法中比较节能的方法,但由于太阳能间断性和不稳定性,单一利用太阳能干燥将大大降低干燥效率,并且由于农产品物料的多样性和性质的复杂性,单一太阳能干燥很难满足干品的质量要求,常常采用的办法是和其他能源结合。本文从新能源开发利用与节能减排的角度出发,基于湛江地区农户对农产品干燥的需求现状,设计了一种太阳能与热泵联合干燥装置,利用该装置对白萝卜进行干燥实验,验证了该装置的干燥效果,结果表明该干燥装置的运行经济可靠,并具有良好的农产品干燥效果。

  18. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    Science.gov (United States)

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  19. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    Science.gov (United States)

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  20. Environmental impact of the programs of substitution of room type air conditioning equipment; Impacto ambiental de los programas de sustitucion de equipos de aire tipo cuarto

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon Aleman, Jose Mauricio [OLADE, Quito (Ecuador)

    2002-09-01

    The present article approaches in a general way the relation that exists between the environment and the saving of electrical energy, especially in the Programs of Demand Side Management (DSM). In particular form the potential environmental impacts are described, derived of the use and the discard of the room type air conditioning equipment, goes deep into the characteristics of their cooling fluids, as well as in the relation that these keep with the protocols of Montreal and Kyoto. Finally, this article comments the incidence which have, the manufacturers as the institutions that implement DSM programs, on the environmental part of the programs of substitution of room type air conditioning equipment. In addition it is briefly described, the pilot program developed by Fideicomiso para el Ahorro de Energia Electrica (FIDE) as a successful case. [Spanish] En forma general, el presente articulo aborda la relacion que existe entre el medio ambiente y el ahorro de energia electrica, especialmente en los Programas de Administracion por el Lado de la Demanda (ALD). En forma particular se describen los impactos ambientales potenciales, derivados del uso y desecho de los equipos de aire acondicionado tipo cuarto, se ahonda en las caracteristicas de sus refrigerantes, asi como en la relacion que estos guardan con los protocolos de Montreal y Kioto. Finalmente, se comenta la incidencia que tienen, tanto los fabricantes como las instituciones que implementan programas de ALD, sobre la parte ambiental de los programas de sustitucion de equipos de aire acondicionado tipo cuarto. Ademas se describe brevemente, el programa piloto desarrollado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE) como un caso exitoso.

  1. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  2. Estimated potential of energy saving and reduction of the demand commercial buildings illumination; Potencial estimado de ahorro de energia y reduccion de la demanda en iluminacion de edificios comerciales

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Gomez, Victor Hugo; Morillon Galvez, David [Posgrado en Energetica de la DEPFI-UNAM, Mexico, D. F. (Mexico)

    1999-07-01

    In this paper the estimated energy saving potential in illumination, the energy end use and the technology used in commercial buildings of different use is analyzed. Estimation that departs from information of the Fideicomiso para el Ahorro de Energia (FIDE) demonstrative cases, presents the energy saving and the demand reduction in a sample of 29 buildings, among which are shopping malls, hospitals, schools, hotels, restaurants and public buildings in which energy saving programs have been carried out, with measures such as the cleaning of the luminaries and its replacement for more efficient ones. The average saving obtained is of 21.81%, in the following areas: illumination, air conditioning and others. In addition, in a sample of 4 buildings, it was observed that before applying the energy saving programs, two of them did not fulfill with the norm NOM-007-1995 (electric power density in interior lighting systems W/m{sup 2}) and later did fulfill the values and criteria of the norm. [Spanish] En el presente trabajo se analiza el potencial estimado de ahorro de energia en iluminacion, el uso final de la energia y la tecnologia empleada en edificios comerciales de uso distinto. Estimacion que parte de la informacion de los casos demostrativos del Fideicomiso para el Ahorro de Energia (FIDE), se presenta el ahorro y reduccion de la demanda en una muestra de 29 edificios, entre los que se tienen centros comerciales, hospitales, escuelas, hoteles, restaurantes y edificios publicos en los cuales se ha llevado a cabo programas de ahorro de energia, con medidas como la limpieza de las luminarias y su remplazo por otros mas eficientes. El ahorro promedio obtenido es de 21.81%, en las siguientes areas: iluminacion, aire acondicionado y otros. Ademas, en una muestra de 4 edificios, se observo que antes de aplicar los programas de ahorro de energia, dos no cumplian con la norma NOM-007-ENER-1995 (densidad de potencia electrica en alumbrado interior W/m{sup 2}) y

  3. 40 CFR 63.1026 - Pumps in light liquid service standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Pumps in light liquid service... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 2 Standards § 63.1026 Pumps in... owner or operator shall monitor each pump to detect leaks and shall comply with all other provisions...

  4. 40 CFR 265.1052 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Pumps in light liquid..., STORAGE, AND DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to...

  5. 46 CFR 28.255 - Bilge pumps, bilge piping, and dewatering systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Bilge pumps, bilge piping, and dewatering systems. 28... the Aleutian Trade § 28.255 Bilge pumps, bilge piping, and dewatering systems. (a) Each vessel must be equipped with a bilge pump and bilge piping capable of draining any watertight compartment, other...

  6. 46 CFR 167.45-5 - Steam fire pumps or their equivalent.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Steam fire pumps or their equivalent. 167.45-5 Section... NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-5 Steam fire pumps or their equivalent. (a) All nautical school ships shall be equipped with fire pumps. (b) Nautical...

  7. 40 CFR 264.1052 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Pumps in light liquid... DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 264.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect leaks by...

  8. 40 CFR 63.1007 - Pumps in light liquid service standards.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Pumps in light liquid service... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1007 Pumps in light liquid... operator shall monitor each pump monthly to detect leaks and shall comply with all other provisions of...

  9. 40 CFR 65.107 - Standards: Pumps in light liquid service.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Pumps in light liquid... PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.107 Standards: Pumps in light... § 65.102(b) or paragraph (e) of this section, the owner or operator shall monitor each pump to...

  10. 46 CFR 154.315 - Cargo pump and cargo compressor rooms.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargo pump and cargo compressor rooms. 154.315 Section... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Ship Arrangements § 154.315 Cargo pump and cargo compressor rooms. (a) Cargo pump rooms and...

  11. 75 FR 14368 - Energy Conservation Standards for Residential Central Air Conditioners and Heat Pumps: Public...

    Science.gov (United States)

    2010-03-25

    ... and heat pumps; the analytical framework, models, and tools that DOE is using to evaluate amended... Heat Pumps, EERE-2008-BT- STD-0006, 1000 Independence Avenue, SW., Washington, DC 20585-0121. Telephone... industrial equipment, including residential central air conditioners and heat pumps. (42 U.S.C. 6292(3)) In...

  12. 10 CFR 431.92 - Definitions concerning commercial air conditioners and heat pumps.

    Science.gov (United States)

    2010-01-01

    ... heat pumps. 431.92 Section 431.92 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Air Conditioners and Heat Pumps § 431.92 Definitions concerning commercial air conditioners and heat pumps. The following definitions apply...

  13. Análisis del impacto económico y financiero de un programa de ahorro de agua en los dispositivos de descarga en sanitarios de una institución de educación básica

    OpenAIRE

    2006-01-01

    Uno de los temas centrales del IV Foro Mundial del Agua, realizado en la Ciudad de México en marzo de 2006 fueron el ahorro y cuidado del agua en el mundo. Para lograr dichos ahorros se requieren cambios radicales en los que el proceso de toma de decisiones se torna muy importante, debido a los costos que por lo regular implican dichos cambios. Esta Tesis pretende demostrar que los programas de ahorro y cuidado del agua no brindan solamente beneficios ambientales o sustenta...

  14. Energy efficient ammonia heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Claus; Pijnenburg, B.; Schumann Grindorf, H. [Danish Technological Institute, Aarhus (Denmark); Christensen, Rolf [Alfa Laval, Lund (Sweden); Rasmussen, Bjarne D. [Grundfos, Bjerringbro (Denmark); Gram, S.; Fredborg Jakobsen, D. [Svedan Industri Koeleanlaeg, Greve (Denmark)

    2013-09-15

    The report describes the development of a highly effective ammonia heat pump. Heat pumps play an increasingly important role in the search for more effective use of energy in our society. Highly efficient heat pumps can contribute to reduced energy consumption and improved economy of the systems which they are a part of. An ammonia heat pump with high pressure reciprocating compressor and a novel split condenser was developed to prove potential for efficiency optimization. The split of the condenser in two parts can be utilized to obtain smaller temperature approaches and, thereby, improved heat pump efficiency at an equal heat exchanger area, when compared to the traditional solution with separate condenser and de-superheater. The split condenser design can also be exploited for heating a significant share of the total heating capacity to a temperature far above the condensing temperature. Furthermore, the prototype heat pump was equipped with a plate type evaporator combined with a U-turn separator with a minimum liquid height and a liquid pump with the purpose of creating optimum liquid circulation ratio for the highest possible heat transfer coefficients at the lowest possible pressure drop. The test results successfully confirmed the highest possible efficiency; a COP of 4.3 was obtained when heating water from 40 deg. C to 80 deg. C while operating with evaporating/condensing temperatures of +20 deg C/+73 deg C. (Author)

  15. A study on diagnostic techniques of pump operating condition

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Du Eon; Park, Jong Ho; Song, Gyu Jo; Shin, Pil Kwon; Lee, Nam Gil; Shin, Wan Sun; Kang, Hyeon Taek; Lee, Taek Sang [Chungnam National Univ., Taejon (Korea, Republic of)

    1998-03-15

    The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.

  16. [Design and optimization of a centrifugal pump for CPCR].

    Science.gov (United States)

    Pei, J; Tan, X; Chen, K; Li, X

    2000-06-01

    Requirements for an optimal centrifugal pump, the vital component in the equipment for cardiopulmonary cerebral resuscitation(CPCR), have been presented. The performance of the Sarns centrifugal pump (Sarns, Inc./3M, Ann arbor, MI, U.S.A) was tested. The preliminarily optimized model for CPCR was designed according to the requirements of CPCR and to the comparison and analysis of several clinically available centrifugal pumps. The preliminary tests using the centrifugal pump made in our laboratory(Type CPCR-I) have confirmed the design and the optimization.

  17. Alternative backing up pump for turbomolecular pumps

    Science.gov (United States)

    Myneni, Ganapati Rao

    2003-04-22

    As an alternative to the use of a mechanical backing pump in the application of wide range turbomolecular pumps in ultra-high and extra high vacuum applications, palladium oxide is used to convert hydrogen present in the evacuation stream and related volumes to water with the water then being cryo-pumped to a low pressure of below about 1.e.sup.-3 Torr at 150.degree. K. Cryo-pumping is achieved using a low cost Kleemenco cycle cryocooler, a somewhat more expensive thermoelectric cooler, a Venturi cooler or a similar device to achieve the required minimization of hydrogen partial pressure.

  18. Hot conditioning equipment conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    Bradshaw, F.W., Westinghouse Hanford

    1996-08-06

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

  19. Large electromagnetic pumps. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kilman, G.B.

    1976-01-01

    The development of large electromagnetic pumps for the liquid metal heat transfer systems of fission reactors has progressed for a number of years. Such pumps are now planned for fusion reactors and solar plants as well. The Einstein-Szilard (annular) pump has been selected as the preferred configuration. Some of the reasons that electromagnetic pumps may be preferred over mechanical pumps and why the annular configuration was selected are discussed. A detailed electromagnetic analysis of the annular pump, based on slug flow, is presented. The analysis is then used to explore the implications of large size and power on considerations of electromagnetic skin effect, geometric skin effect and the cylindrical geometry.

  20. Equipment. Out of order.

    Science.gov (United States)

    Connolly, C

    2000-08-17

    The NHS has underinvested in equipment for more than 20 years. Most hospitals have inadequate equipment inventories. More than half the anaesthetic machines in use are more than five years old and should be replaced. Almost a fifth of the equipment used in cancer treatment is obsolete. Current accounting systems act as a disincentive to replacing old equipment.

  1. Economía y sociedad en Burgos (1890-1936): la Caja de Ahorros del Círculo Católico

    OpenAIRE

    Chicote Ureta, María Felicidad

    2016-01-01

    El objetivo que pretende alcanzar esta investigación y la metodología que se va a utilizar conducen a un propósito: realizar un análisis de la Caja de Ahorros y Monte de Piedad del Círculo Católico de Obreros de Burgos –a lo largo de sesenta años– que ponga de relieve su impacto real sobre la sociedad en la que se instala y ayude a explicar su contribución en el devenir de la historia burgalesa de la segunda mitad del siglo XX. Aspira a presentar a la Institución como un síntoma, como la resp...

  2. Evaluation of the energy saving potential in illumination using presence sensors; Evaluacion del potencial de ahorro de energia en iluminacion utilizando sensores de presencia

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Eslava, Alejandro [Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1999-07-01

    The analysis and the evaluation of the energy saving that would provide a system of illumination controlled by sensors of presence in an enclosure with low transit, evaluating the economic profitability of the system is presented. The data, from which the analysis is sustained and the results are deducted, coming from the use and installation of a timer in the area. [Spanish] Se presenta el analisis y la evaluacion de los ahorros de energia que suministraria un sistema de iluminacion controlado por sensores de presencia en un recinto con bajo transito, evaluando la rentabilidad economica del sistema. Los datos, a partir de los cuales se sustenta el analisis y se deducen los resultados, provienen de la utilizacion e instalacion de un contador de tiempo de uso en el recinto.

  3. Design aspects and conservation of roads in the saving of energy; Aspectos de diseno y conservacion de carreteras en el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Cajun, Carlos S.; Aguerrebere Salido, Roberto [Instituto Mexicano del Transporte, Queretaro (Mexico)

    1992-12-31

    In this paper the effects that on the fuel consumption the roads have for their slopes and roughness are presented. A mathematical model is presented which shows the relationship between the slope, the roughness coefficient and the required power to overcome the corresponding resistance; the former in order to predict the fuel consumption and therefore, the potential level of energy saving corresponding to this item. [Espanol] En este trabajo se presentan los efectos que sobre consumo de combustible se tienen, debido a las pendientes y rugosidades de las carreteras. Se presenta un modelo matematico que muestra la relacion entre la pendiente, el coeficiente de rodamiento y la potencia requerida para vencer las resistencias correspondientes; lo anterior con el fin de predecir el consumo de combustible y, por lo tanto, los niveles potenciales de ahorro de energia correspondientes a este rubro.

  4. Ahorro infantil: “Chispitas”-Estrategia para combatir la pobreza, Fundación Ayú, Oaxaca, México

    OpenAIRE

    Guadalupe Arcos-Medina*; Emma Zapata-Martelo; Oliverio Hernández-Romero

    2016-01-01

    En esta investigación analizamos cómo la estrategia de combate a la pobreza de la Fundación Ayú, influye en el hábito del ahorro de los niños y niñas mixtecos de Oaxaca -los “Chispitas”-, con datos obtenidos de noviembre de 2013 a julio de 2014. Realizamos un taller participativo y entrevistas semiestructuradas, aplicando un cuestionario a 42 niños y niñas de diez años de edad promedio, y antigüedad como ahorradores de entre tres y siete años. El perfil socioeconómico familiar corresponde may...

  5. Implementacion del modelo Lean Service en el proceso de recaudo de la Cooperativa de Ahorro y Crédito Fincomercio ltda

    Directory of Open Access Journals (Sweden)

    Jonny Gavilán

    2016-12-01

    Full Text Available El presente trabajo forma parte de la tesis de maestría, para optar al título de Magister en Ingeniería Industrial de la Universidad Distrital Francisco José de Caldas. El cual se basó fundamentalmente en el diseño e implementación del modelo Lean Service para el proceso de recaudo de la Cooperativa de Ahorro y Crédito Fincomercio Ltda. En este marco de referencia, la presente investigación de tipo Descriptivo – Explicativo consistirá en la aplicación de la metodología Lean Service para el mejoramiento del proceso de recaudo de la Cooperativa.

  6. Las cajas de ahorro en el sistema financiero español. Trayectoria histórica y realidad histórica actual.

    OpenAIRE

    Cals, Joan,

    2002-01-01

    La OCDE (1971) calificaba al sistema financiero español, a comienzos de los años setenta, como uno de los más rígidos y reglamentados de los países que integraban la organización. A su vez, la cajas de ahorros españolas figuraban entre las que de forma más restrictiva debían desarrollar sus actividades (Ros, 1967). Por ello, era lógico que a partir de 1973-74 y, especialmente, 1977, se iniciara un proceso de reforma y liberalización que operaría en diversos frentes y daría paso a la equiparac...

  7. Ahorro energético y cogeneración en el sector hotelero de Cozumel y la Riviera Maya (México)

    OpenAIRE

    Mendoza Vizcaino, Fco. Javier

    2013-01-01

    En este trabajo se desarrollará un ejercicio de ahorro energético y cogeneración en un hotel de Cozumel (Riviera Maya) México. Para esto, se requiere de la implementación de un sistema de conversión de los residuos orgánicos en biogás, el cual alimente a un equipo de cogeneración y así, la producción y una mejor gestión de la energía, sean una solución viable para disminuir el costo de operación y la emisión de gases de efecto invernadero (GEI) buscando obtener una bonificación...

  8. Evaluation of saving measurements and energetic efficiency in air-conditioning systems; Evaluacion de medidas de ahorro y eficiencia energetica en sistemas de climatizacion

    Energy Technology Data Exchange (ETDEWEB)

    Perez Lombard, L [Asociacion de Investigacion y Cooperacion de Andalucia (Spain); Ortiz, J [Building Research Establishment (United Kingdom); Riviere, P [Armines-ecole des mines de Paris (France)

    2006-04-15

    Buildings require an adequate air conditioning to offer workers a labor environment where there is thermal comfort. A study was performed in three different European places which count on several climates. The conclusion was the following: in order to analyze the energy efficiency in edifications it is fundamental the simulation tools use with the purpose of calculating the consumption and evaluating the saving measurements. [Spanish] Los edificios requieren de una climatizacion adecuada para que los que ahi operan puedan hacerlo dentro de un ambiente laboral donde exista el confort termico. Se llevo a cabo un estudio en tres lugares de Europa poseedores de diferentes climas y se concluyo que para poder analizar la eficiencia energetica de climatizacion en las edificaciones es imprescindible el uso de herramientas de simulacion con el proposito de calcular el consumo y evaluar las medidas de ahorro.

  9. Strategy Guideline: HVAC Equipment Sizing

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2012-02-01

    The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  10. Experiences on energy saving in Comision Federal Electricidad (CFE) buildings; Experiencias de ahorro de energia en edificios de la Comision Federal de Electricidad (CFE)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Velasco, Jorge E. [Comision Federal de Electricidad (CFE) (Mexico)

    2005-07-01

    This document describes the developed saving projects in buildings and generating power stations in 2004 by the Comision Federal de Electricidad (CFE). The projects considered are: buildings of the oficinas nacionales, Divisions of distribution office buildings, office buildings of production regions, construction deputy manager's office building, buildings of transmission and transformation, generating power stations, investments and savings of the projects in oficinas nacionales, divisions of distribution and construction subdivision buildings. From these projects the ones concluded in the 2004 were: Distribution Divisions, Gulf-Center Division, Center-West Distribution Division. The developing projects of 2005: oficinas nacionales, distribution divisions, Construction Subdivision, Generating Power Stations, Transmission Areas and office buildings. And finally, the projects concluded in the 2005 are the distribution divisions, the construction subdivision, the generating power stations, the office buildings, the minisplit units and their advantages with respect to the air conditioning window units. [Spanish] Este documento describe los proyectos de ahorro desarrollados en inmuebles y centrales generadoras en el ano 2004 por la Comision Federal de Electricidad (CFE), los proyectos tratados son: inmuebles de oficinas nacionales, inmuebles de divisiones de distribucion, inmuebles de regiones de produccion, inmuebles de la subdireccion de construccion, inmuebles de transmision y transformacion, centrales generadoras, inversiones y ahorros de los proyectos en inmuebles de oficinas nacionales y divisiones de distribucion y subdireccion de construccion. De dichos proyectos se tiene que los proyectos concluidos en el 2004 fueron: Divisiones de Distribucion, Division Golfo Centro, Division de Distribucion Centro Occidente. Los proyectos en desarrollo del 2005: oficinas nacionales, divisiones de distribucion, Subdireccion de Construccion, Centrales Generadoras, Areas

  11. Valoración de la garantía de pensión en las cuentas de ahorro individual en colombia

    Directory of Open Access Journals (Sweden)

    José V. Restrepo

    2011-09-01

    Full Text Available El comportamiento del individuo como persona que aporta, y futuro beneficiario de una pensión, es determinante para cuantificar los efectos que su densidad de aportes tiene sobre el sistema de ahorro individual y la exigibilidad de las diferentes garantías. Por esta razón, en el presente trabajo se intenta buscar desde las finanzas personales una visión alterna a lo expuesto en diferentes estudios que sobre la materia se han realizado, no solo en Colombia sino a nivel internacional, y brindar una aproximación a la solución del problema de sostenibilidad en el retiro. Para calcular la magnitud de las garantías, se desarrolló un procedimiento que combina metodologías de modelos estocásticos con modelos de lógica difusa y con el cálculo actuarial. de esta forma, y soportado en resultados de otros estudios, se logró determinar el ahorro individual potencial alcanzable por cada individuo en función de su género y su cohorte salarial, y el posible déficit existente para conseguir una pensión mínima de retiro. los resultados encontrados indican que en las condiciones de baja densidad de aportes es muy difícil para las cohortes de bajo y medio ingreso asegurar una pensión mínima sin el agotamiento de las garantías existentes y la participación del gobierno.

  12. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction rela...... to a part of the tube. The invention further relates to a method for creating a flow of a fluid within an at least partly flexible tube by means of a pump element as mentioned above.......The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  13. Video requirements plan for the HMT equipment removal system

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F. Jr.

    1995-02-01

    This document is the plan defining the video coverage requirements for the equipment removal event of the Hydrogen Mitigation Test (HMT) mixer pump currently installed in high level nuclear waste storage Tank 241-SY-101. When the mixer pump fails the removal and installation of a spare pump will be a time critical event. Since the success of the HMT mixer pump has resolved the DOE safety issue it is absolutely essential that mixing be restored to the tank in a short as time possible. Therefore, the removal of the failed pump and the installation of the spare pump must be anticipated and planned well in advance. The removal, containment, transporting, and storage of the failed pump is a very complex and hazardous task. The successful completion of this task will require careful planning and monitoring. Certain events, during the removal and subsequent installation of the new pump, will require video observation and storage for safety, documenting, training, and promotional use. Furthermore, certain events will require close monitoring and observation by the event directors and key supervisory personnel for the execution of specific tasks during the equipment removal event.

  14. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This ...

  15. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  16. Pump for Saturated Liquids

    Science.gov (United States)

    Elliott, D. G.

    1986-01-01

    Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.

  17. Proceedings of the 22 National seminar on the rational an efficient use of energy and exposition of equipment and services. [Selected Papers]; 22. Seminario nacional sobre el uso racional y eficiente de la energia y exposicion de equipos y servicios. Memoria Tecnica. [Ponencias seleccionadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This document contains the proceedings of the 22 national seminar on the rational and efficient use of energy and exposition of equipment and services, organized by the Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), in Mexico, D.F., from the 25 to the 29 of August of 2003. This Seminar covered subjects such as: Energy saving in the power sector, power efficiency in industrial processes and practical developments, practical cases of energy saving in industry, energy saving in constructions, transport, utilization of renewable energies and the environment. [Spanish] Este documento contiene la memoria tecnica del 22 seminario nacional sobre el uso racional y eficiente de la energia y exposicion de equipos y servicios, organizado por la Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), en Mexico, D.F., del 25 al 29 de agosto de 2003. Este seminario trato de temas tales como: Ahorro de energia en el sector energetico, eficiencia energetica en procesos industriales y desarrollos practicos, casos practicos de ahorro de energia en la industria, ahorro de energia en edificaciones, transporte, aprovechamiento de energias renovables y ambiente.

  18. Vertical pump turbine oil environmental evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Culver, G.

    1991-04-01

    In Oregon low-temperature geothermal injection well construction, siting and receiving formations requires approval by the Water Resources Department (OWRD). In addition, the Oregon Department of Environmental Quality (ODEQ) has regulations concerning injection. Conversations with the OWRD and ODEQ representatives indicated they were very concerned about the potential for contamination of the geothermal (and cooler but hydraulically connected) aquifers by oils and grease. Their primary concern was over the practice of putting paraffin, motor oils and other hydrocarbons in downhole heat exchanger (DHE) wells to prevent corrosion. They also expressed considerable concern about the use of oil in production well pumps since the fluids pumped would be injected. Oregon (and Idaho) prohibit the use of oil-lubricated pumps for public water supplies except in certain situations where non-toxic food-grade lubricants are used. Since enclosed-lineshaft oil-lubricated pumps are the mainstay of direct-use pumping equipment, the potential for restricting their use became a concern to the Geo-Heat Center staff. An investigation into alternative pump lubrication schemes and development of rebuttals to potential restrictions was proposed and approved as a contract task. (SM)

  19. Technical and Economic Working Domains of Industrial Heat Pumps: Part 1 - Vapour Compression Heat Pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Jensen, Jonas Kjær; Markussen, Wiebke Brix

    2014-01-01

    A large amount of operational and economic constraints limit the applicability of heat pumps operated with natural working fluids. The limitations are highly dependent on the integration of heat source and sink streams. An evaluation of feasible operating conditions is carried out considering...... the constraints of available refrigeration equipment and a requirement of a positive Net Present Value of the investment. The considered sink outlet temperature range is from 40 °C to 140 °C, but for the heat pumps considered in this paper, the upper limit is 100 °C. Five heat pumps are studied. For each set...... of heat sink and source temperatures the optimal solution is determined. At low sink temperature glide R717 heat pumps show best performance, while at higher sink glide transcritical R744 may become important. In a second paper, the results of the VCHP are compared to a similar study considering...

  20. Common NICU Equipment

    Science.gov (United States)

    ... newborn intensive care unit (NICU) > Common NICU equipment Common NICU equipment E-mail to a friend Please ... Baby Caring for your baby Feeding your baby Common illnesses Family health & safety Complications & Loss Pregnancy complications ...

  1. The methodology for the evaluation of the energy saving by the daylight saving time in Mexico; Metodologia para la evaluacion del ahorro de energia debido al cambio de horario durante la epoca del verano

    Energy Technology Data Exchange (ETDEWEB)

    Ramos Niembro, Gaudencio [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    A description is made of the methodology for the evaluation of energy saving by the daylight saving time in Mexico. A mathematical model was developed that would allow the quantitative evaluation of the energy saving by the daylight saving time, through measurements of the consumption of different users from the domestic commercial and industrial sector, considering the various variables that impact the consumption [Espanol] Se describe la metodologia para la evalucion del ahorro de energia por el cambio de horario de verano en Mexico. Se desarrollo un modelo matematico que permitiera evaluar cuantitativamente el ahorro de energia debido al cambio de horario durante la epoca de verano, atraves de mediciones de consumos de los diferentes usuarios de los sectores domestico, comercial e industrial, considerando las diversas variables que impactan en el consumo

  2. Ahorro de energía eléctrica por implementación de filtros desecantes en sistemas de acondicionamiento de aire por compresión de vapor

    Directory of Open Access Journals (Sweden)

    Antonio José Bula Silvera

    2004-01-01

    Full Text Available Una serie de experimentos exploratorios han sido llevados a cabo para determinar cómo se afecta el desempeño energético de un sistema de aire acondicionado por compresión de vapor al trabajar con un filtro deshumidificador instalado en la línea de retorno del aire hacia el evaporador. Los experimentos se realizaron considerando sistemas con alta y baja carga latente, y se observo cómo variaba el consumo de energía del equipo. Se encontró que al estar sometido el sistema de aire acondicionado a altas cargas latentes, el ahorro de energía al instalar estos filtros desecantes puede llegar a 14,5% mientras que al estar sometido el sistema a bajas cargas latentes, el ahorro sólo llega a 2%.

  3. Variations in battery life of a heart-lung machine using different pump speeds, pressure loads, boot material, centrifugal pump head, multiple pump usage, and battery age.

    LENUS (Irish Health Repository)

    Marshall, Cornelius

    2012-02-03

    Electrical failure during cardiopulmonary bypass (CPB) has previously been reported to occur in 1 of every 1500 cases. Most heart-lung machine pump consoles are equipped with built-in battery back-up units. Battery run times of these devices are variable and have not been reported. Different conditions of use can extend battery life in the event of electrical failure. This study was designed to examine the run time of a fully charged battery under various conditions of pump speed, pressure loads, pump boot material, multiple pump usage, and battery life. Battery life using a centrifugal pump also was examined. The results of this study show that battery life is affected by pump speed, circuit pressure, boot stiffness, and the number of pumps in service. Centrifugal pumps also show a reduced drain on battery when compared with roller pumps. These elements affect the longevity and performance of the battery. This information could be of value to the individual during power failure as these are variables that can affect the battery life during such a challenging scenario.

  4. Rectilinear Electromechanical Pumping Developed Successfully in China

    Institute of Scientific and Technical Information of China (English)

    Jiao Nianyou; Jiao Fangjie

    2006-01-01

    @@ Recently, the special subject-development and application of rectilinear electromechanical pumping undertaken by Jianghan Petroleum Machinery Factory and China University of Petroleum (East China) Electromechanical Project Institute, which is the component of national key project for domestic petroleum equipment, new material development and application technology during the period of the 11th Five-Year Plan,was passed through the appraisal and acceptance by the CNPC's experts team authorized by Ministry of Science and Technology in Beijing.

  5. Compact High Efficiency Adsorption Heat Pump

    OpenAIRE

    TeGrotenhuis, Ward E; Humble, Paul H; Sweeney, Josh B

    2012-01-01

    An innovative adsorption cycle heat pump technology is presented that is compact and capable of achieving high energy efficiency for integrated space heating, air conditioning, and water heating. High energy efficiency is accomplished by effectively recuperating heat within the system to minimize energy consumption. This substantially reduces the thermodynamic losses that occur when the sorbent beds are thermally cycled without effective heat recuperation. Furthermore, equipment cost is reduc...

  6. 33 CFR 150.531 - How many fire pumps must be kept ready for use at all times?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How many fire pumps must be kept... Specialty Equipment Miscellaneous Operations § 150.531 How many fire pumps must be kept ready for use at all times? At least one of the fire pumps required by this subchapter must be kept ready for use at...

  7. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  8. Análisis de costes y ahorros potenciales relacionados con la utilización de pruebas preoperatorias en los hospitales de Canarias

    Directory of Open Access Journals (Sweden)

    López-Bastida J.

    2003-01-01

    Full Text Available Objetivos: Estimar el ahorro potencial que podría tener lugar en el Servicio Canario de Salud (SCS, a partir de una utilización apropiada científica de las pruebas preoperatorias, haciendo uso de la información obtenida de los 5 hospitales universitarios de la red pública. Métodos: Un total de 55 anestesiólogos (60% del SCS cumplimentaron un cuestionario. En éste se prestó especial atención a las pruebas preoperatorias más frecuentemente utilizadas, como la radiografía de tórax, el electrocardiograma, las pruebas de laboratorio y la espirometría. Los costes unitarios medios para las diferentes pruebas preoperatorias se obtuvieron de 2 hospitales participantes en el estudio. Para calcular los ahorros potenciales derivados del uso apropiado de las pruebas preoperatorias se han considerado varios escenarios caracterizados por diferentes hipótesis o grados de cumplimiento de un protocolo basado en el conocimiento científico, considerado como parámetro de referencia. Resultados: En el caso ideal de que se cumpliera el protocolo científico recomendado en el 100% de los 16.179 pacientes considerados ASA I y II, la repercusión económica sería notable, pues supondría una liberación de recursos sensible que podría ser utilizada para otros programas de salud. Estas cifras podrían alcanzar aproximadamente los 1,02 millones de euros, sin considerar el coste de la estancia preoperatoria. Esta cifra podría incrementarse hasta, aproximadamente, los 2,13 millones de euros si incluimos un día de estancia preoperatoria, y hasta los 3,24 millones de euros incluyendo 2 días de estancia preoperatoria. Conclusiones: La revisión reciente de la literatura científica y los resultados proporcionados por el cuestionario aplicado en el SCS indican que las pruebas preoperatorias alcanzan los mayores beneficios para los pacientes y para la sociedad si se guían por el conocimiento científico. Es posible, además, liberar recursos a partir de una

  9. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  10. Sucker-rod pumping handbook production engineering fundamentals and long-stroke rod pumping

    CERN Document Server

    Takacs, Gabor

    2015-01-01

    Sucker-Rod Pumping Handbook presents the latest information on the most common form of production enhancement in today's oil industry, making up roughly two-thirds of the producing oilwell operations in the world. The book begins with an introduction to the main features of sucker rod pumping and an explanation and comparison of lift methods. It goes on to provide the technical and practical knowledge needed to introduce the new and practicing production engineer and operator to the equipment, technology, and applications required to maintain optimum operating conditions.

  11. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed.

  12. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  13. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  14. Resonance wave pumping: wave mass transport pumping

    Science.gov (United States)

    Carmigniani, Remi; Violeau, Damien; Gharib, Morteza

    2016-11-01

    It has been previously reported that pinching at intrinsic resonance frequencies a valveless pump (or Liebau pump) results in a strong pulsating flow. A free-surface version of the Liebau pump is presented. The experiment consists of a closed tank with a submerged plate separating the water into a free-surface and a recirculation section connected through two openings at each end of the tank. A paddle is placed at an off-centre position at the free-surface and controlled in a heaving motion with different frequencies and amplitudes. Near certain frequencies identified as resonance frequencies through a linear potential theory analysis, the system behaves like a pump. Particle Image Velocimetry (PIV) is performed in the near free surface region and compared with simulations using Volume of Fluid (VOF) method. The mean eulerian mass flux field (ρ) is extracted. It is observed that the flow is located in the vicinity of the surface layer suggesting Stokes Drift (or Wave Mass Transport) is the source of the pumping. A model is developped to extend the linear potential theory to the second order to take into account these observations. The authors would like to acknowledge the Gordon and Betty Moore Foundation for their generous support.

  15. East Mesa geothermal pump test facility (EMPTF). Final report

    Energy Technology Data Exchange (ETDEWEB)

    Olander, R.G.; Roberts, G.K.

    1984-11-28

    The design, fabrication and installation of a geothermal pump test facility (EMPFT) at the DOE geothermal site at East Mesa, California which is capable of testing 70 to 750 horsepower downwell pumps in a controlled geothermal environment were completed. The facility consists of a skid-mounted brine control module, a 160 foot below test well section, a hydraulic turbine for power recovery, a gantry-mounted hoist for pump handling and a 3-phase, 480 VAC, 1200 amp power supply to handle pump electric requirements. Geothermal brine is supplied to the EMPTF from one of the facility wells at East Mesa. The EMPTF is designed with a great amount of flexibility. The 20-inch diameter test well can accommodate a wide variety of pumps. The controls are interactive and can be adjusted to obtain a full complement of pump operation data, or set to maintain constant conditions to allow long-term testing with a minimum of operator support. The hydraulic turbine allows the EMPTF user to recover approximately 46% of the input pump power to help defray the operating cost of the unit. The hoist is provided for material handling and pump servicing and reduces the equipment that the user must supply for pump installation, inspection and removal.

  16. East Mesa geothermal pump test facility (EMPTF). Final report

    Energy Technology Data Exchange (ETDEWEB)

    Olander, R.G.; Roberts, G.K.

    1984-11-28

    Barber-Nichols has completed the design, fabrication and installation of a geothermal pump test facility at the DOE geothermal site at East Mesa, California which is capable of testing 70 to 750 horsepower downwell pumps in a controlled geothermal environment. The facility consists of a skid-mounted brine control module, a 160 foot below ground test well section, a hydraulic turbine for power recovery, a gantry-mounted hoist for pump handling and a 3-phase, 480 VAC, 1200 amp power supply to handle pump electric requirements. Geothermal brine is supplied to the EMPTF from one of the facility wells at East Mesa. The EMPTF is designed with a great amount of flexibility to attract the largest number of potential users. The 20-inch diameter test well can accommodate a wide variety of pumps. The controls are interactive and can be adjusted to obtain a full complement of pump operation data, or set to maintain constant conditions to allow long-term testing with a minimum of operator support. The hydraulic turbine allows the EMPTF user to recover approximately 46% of the input pump power to help defray the operating cost of the unit. The hoist is provided for material handling and pump servicing and reduces the equipment that the user must supply for pump installation, inspection and removal.

  17. Reliance on Pumped Mother's Milk Has an Environmental Impact.

    Science.gov (United States)

    Becker, Genevieve; Ryan-Fogarty, Yvonne

    2016-09-10

    Breastfeeding is an environmentally friendly process; however when feeding relies on pumped mother's milk, the environmental picture changes. Waste plastics and heavy metals raise concerns regarding resource efficiency, waste treatment, and detrimental effects on health. Reliance on pumped milk rather than breastfeeding may also effect obesity and family size, which in turn have further environmental impacts. Information on pump equipment rarely includes environmental information and may focus on marketing the product for maximum profit. In order for parents, health workers, and health policy makers to make informed decisions about the reliance on pumped mother's milk, they need information on the broad and far reaching environmental aspects. There was no published research found that examined the environmental impact of using pumped mother's milk. A project is ongoing to examine this issue.

  18. Demanding pump power; Krevende pumpekraft

    Energy Technology Data Exchange (ETDEWEB)

    Lie, Oeyvind

    2011-07-01

    The potential for pump power in Norway is huge, but it is difficult to exploit it. Norway has some pumping plants, but these are built for seasonal pumping (pumping up to the magazine in the summer, and production in the winter). Pump power plants for short periods do not exist in Norway. (AG)

  19. Scenarios simulation for the conservation and efficient use of energy, using passive control measures; Simulacion de escenarios de ahorro y uso eficiente de energia, utilizando medidas de control pasivo

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, G.; Heard, Ch.; Sanchez Viveros, A. [Instituto de Investigaciones Electricas,Cuernavaca (Mexico)

    1997-12-31

    Every one involved with the conservation and efficient use of electric energy, has listened in reiterative occasions to the causes that changed the conventional mentality at the beginning of the seventies. Nevertheless, there are many persons that still ignore that by using the energy rationally, their costs are significantly reduced, their comfort is enhanced and the environmental problems are minimized. Specifically, in the domestic sector, from the figures reported by the Comision Federal de Electricidad (CFE) in 1996, the electric energy sold was 28,410 Gwh, that is, 23.4% of the total consumption (121,579 Gwh). Table 1 presents the average by tariff in the national domestic sector, which shows that 20% of the electricity consumed was required for environmental conditioning (air conditioning, evaporative coolers and electric fans). The above figures quantitatively show that there is a strong impact in the consumption of electric energy due to weather conditions. For this reason, currently the Comision Nacional de Ahorro de Energia (CONAE) and the Fideicomiso para el Ahorro de Energia (FIDE) are promoting standards and projects to propitiate the rationalization in the use of energy, besides of achieving the improvement of thermal comfort conditions. One more case would be the Fideicomiso para el Aislamiento Termico de la Vivienda en Mexicali (FIPATERM), which promotes the financing of saving measures and efficient energy use in cities with extreme climate. This paper describes the strategy that was followed by the Instituto de Investigaciones Electricas (IIE), for the development of the human and material infrastructure, that has allowed the sustainment of several projects in the saving and efficient use of energy in CFE, CONAE, FIDE, FIPATERM and the Lawrence Berkeley National Laboratory (LBNL), concretely in relationship with the thermal analysis of dwellings. [Espanol] Todos aquellos relacionados con el ahorro y el uso eficiente de la energia electrica, han

  20. Ultra high vacuum pumping system and high sensitivity helium leak detector

    Science.gov (United States)

    Myneni, Ganapati Rao

    1997-01-01

    An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.

  1. Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

    Science.gov (United States)

    Lemoff, Asuncion V.; Lee, Abraham P.

    2010-07-13

    A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

  2. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  3. RETRIEVAL EQUIPMENT DESCRIPTIONS

    Energy Technology Data Exchange (ETDEWEB)

    J. Steinhoff

    1997-08-25

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler.

  4. 2007 special equipment safety

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ The General Administration of Quality Supervision, Inspection and Quarantine of P.R.China (AQSIQ) issued a notice on May 28, 2007,requiring various locations to rectify their procedures for checking special equipment and hoisting machines for hidden problems. To further clarify and implement responsibility in the safety management of special equipment in enterprises, inspection responsibilities and test organizations related to technical assurance are to be established. Further, quality inspection departments will be supervised by law in order to improve special equipment safety.

  5. Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure.

    Science.gov (United States)

    Kawahito, Koji

    2013-09-01

    Although non-destructive and continuous monitoring is indispensable for long-term circulatory support with rotary blood pumps, a practical monitoring system has not yet been developed. The objective of this study was to investigate the possibility of detecting pump failure caused by thrombus formation through the monitoring of vibration signals. The data acquisition equipment included vibration pickups, a charge amplifier, vibration analysis systems, and exclusive hardware. A pivot-bearing centrifugal pump with a mock circuit was investigated for vibration analysis. To simulate the four common areas of thrombus formation, we used a piece of silicon attached to each of the following four locations: the total area of the bottom of the impeller, an eccentric shape on the bottom of the impeller, a circular shape around the shaft top, and an eccentric shape on the top of the impeller. Vibration signals were picked up, and the power spectrum density analysis was performed at pump rotational speeds of 2100, 2400, and 3000 rpm. In this study, pump failure could be detected, and the types of imitation thrombi could be determined. We conclude that vibration detection with a computerized analysis system is a potentially valuable diagnostic tool for long-term circulatory support with rotary blood pumps.

  6. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  7. 40 CFR 63.1331 - Equipment leak provisions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Equipment leak provisions. 63.1331 Section 63.1331 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... polymer fluid used to provide lubrication and/or cooling of the pump or agitator shaft exits the...

  8. Actions and results of the management of energy saving of the CONDUMEX group; Acciones y resultados de la gerencia de ahorro de energia de grupo CONDUMEX

    Energy Technology Data Exchange (ETDEWEB)

    Sashida Key, Carlos; Jimenez Huerta, Arturo; Alavez Alcazar, Moises [Grupo Condumex, Industrias IEM, S.A. de C.V., Mexico, D.F. (Mexico)

    1999-07-01

    The purpose of this paper is to expose some practical cases that have been developed through the Energy Saving Management of GRUPO CONDUMEX, in different areas such as systems related to water, steam, electricity and compressed air. This experience has been compiled of diagnoses and actions that have been carried out in the companies inside and outside GRUPO CONDUMEX, and of systems with the purpose of making efficient the use of fuels and getting close to the energy indexes that are handled in other International companies of the same manufacture branch. [Spanish] Este trabajo tiene por objeto exponer algunos casos practicos que se han desarrollado a traves de la Gerencia de Ahorro de Energia de GRUPO CONDUMEX, en distintas areas tales como sistemas relacionados con agua, vapor, electricidad y aire comprimido. Esta experiencia ha sido recopilada de diagnosticos y acciones que se han llevado a cabo en las empresas dentro y fuera de GRUPO CONDUMEX, y de sistemas con la finalidad de eficientar el uso de los energeticos y acercarnos a los indices energeticos que se manejan en otras empresas internacionales del mismo ramo de fabricacion.

  9. Energy saving in buildings through the elimination of typical problems; Ahorro de energia electrica en edificios a traves de la eliminacion de problemas tipicos

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Rivero, Alex G. [Genertek, S. A. de C. V., Mexico, D. F. (Mexico)

    1993-12-31

    The enormous electric energy consumption in buildings represents an important area of saving opportunities. The design of installations without advanced technical illumination criteria, the absence of standardization over energy efficiency, the lack of observation of the existing standards and guides, the continuous load growth in existing installations and the lack of appropriate maintenance, are some of the causes of the inefficient use of electric energy in buildings. Although the problems, and consequently the solutions, are exclusive for each unit, some of the former are frequently repeated. In this paper the problems found along more than 40 audits conducted in large buildings of different types in Mexico city are commented. [Espanol] El enorme consumo de energia electrica en edificios representa una importante area de oportunidad para ahorro. El diseno de instalaciones sin criterios luminotecnicos avanzados, la ausencia de normalizacion sobre eficiencia energetica, la falta de observancia de las normas y recomendaciones vigentes, el continuo crecimiento de carga en instalaciones existentes y la falta de mantenimiento adecuado son algunas de las causas del uso ineficiente de la energia electrica en inmuebles. Aunque los problemas y por tanto las soluciones son particulares para cada unidad, algunos de los primeros se repiten frecuentemente. En este trabajo se comentan los problemas encontrados a lo largo de mas de 40 auditorias realizadas a inmuebles grandes de diversos tipos en la ciudad de Mexico.

  10. The satisfaction of developing a project of electrical energy saving; La satisfaccion de desarrollar un proyecto de ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Arreola Suarez, Alejandro [Hotel Club Marival, Nuevo Vallarta, Nayarit (Mexico)

    2002-09-01

    The projects for the energy saving in hotels represent a great opportunity to reduce the operation costs in the demand and consumption of electrical energy, since the existing facilities can take advantage of new technologies in illumination, air conditioning, refrigeration and heating. By their constitution, the hotels work the year around uninterruptedly and must provide all type of services to the guests and working personnel, which originates that they consume great amounts of energy in air conditioning, lightning, laundry, etc., since the prestige of the installation depends on it. [Spanish] Los proyectos para el ahorro de energia en hoteles representan una gran oportunidad para reducir costos de operacion en la demanda y consumo de energia electrica, ya que las instalaciones existentes pueden aprovechar nuevas tecnologias en iluminacion, aire acondicionado, refrigeracion y calefaccion. Por su constitucion, los hoteles trabajan ininterrumpidamente todo el ano y deben proporcionar toda clase de servicios a los huespedes y personal que labora, lo cual origina que consuman grandes cantidades de energia en aire acondicionado, iluminacion, lavanderia, etc., pues de ello depende el prestigio de la instalacion.

  11. Ahorro infantil: “Chispitas”-Estrategia para combatir la pobreza, Fundación Ayú, Oaxaca, México

    Directory of Open Access Journals (Sweden)

    Guadalupe Arcos-Medina*

    2016-02-01

    Full Text Available En esta investigación analizamos cómo la estrategia de combate a la pobreza de la Fundación Ayú, influye en el hábito del ahorro de los niños y niñas mixtecos de Oaxaca -los “Chispitas”-, con datos obtenidos de noviembre de 2013 a julio de 2014. Realizamos un taller participativo y entrevistas semiestructuradas, aplicando un cuestionario a 42 niños y niñas de diez años de edad promedio, y antigüedad como ahorradores de entre tres y siete años. El perfil socioeconómico familiar corresponde mayormente a hogares campesinos; las razones para ahorrar son la educación, el futuro y las emergencias, siendo las madres quienes mayor influencia tienen en este hábito. Participar en las cajas visibiliza a los niños y niñas en la localidad y los inicia en la inclusión social y financiera.

  12. Composición quimicomineralógica de las materias primas y ahorro de energía en la industria del cemento

    Directory of Open Access Journals (Sweden)

    Soria Santamaría, Francisco

    1982-06-01

    Full Text Available In the field of energy saving, mainly thermic, in the cement industry, not only should we consider the possibilities in the technological process or the finished product, but also the influence of the chemical-mineral composition of the raw materials. The distinct parameters which fall into the reactivity of the crudes are analyzed, such as the size of the grain (fineness, chemical and mineral composition of the principal components. There follows an exposition of the importance of the minority components as smelting and mineralizers, finally emphasizing the interest and practical behaviour of some of them.

    En el campo del ahorro de energía, principalmente térmica, en la industria cementera, no sólo deben contemplarse las posibilidades en cuanto al proceso tecnológico o el producto acabado, sino también la influencia de la composición quimicomineralógica de las materias primas. Se analizan los distintos parámetros que inciden en la reactividad de los crudos, tales como tamaño de grano (finura, composición química y mineralogía de los componentes principales. A continuación se hace una exposición de la importancia de los componentes minoritarios como fundentes y mineralizadores, destacando finalmente el interés y comportamiento práctico de alguno de ellos.

  13. A Shocking New Pump

    Science.gov (United States)

    2000-01-01

    Hydro Dynamics, Inc. received a technical helping hand from NASA that made their Hydrosonic Pump (HPump) a reality. Marshall engineers resolved a bearing problem in the rotor of the pump and recommended new bearings, housings and mounting hardware as a solution. The resulting HPump is able to heat liquids with greater energy efficiency using shock waves to generate heat.

  14. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  15. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D.; Winkler, J.; Kruis, N.; Christensen, C.; Brendemuehl, M.

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  16. Review of magnetohydrodynamic pump applications

    National Research Council Canada - National Science Library

    Al-Habahbeh, O.M; Al-Saqqa, M; Safi, M; Abo Khater, T

    2016-01-01

    Magneto-hydrodynamic (MHD) principle is an important interdisciplinary field. One of the most important applications of this effect is pumping of materials that are hard to pump using conventional pumps...

  17. Energy saving using solar filters with iron base in windows; Ahorro de energia usando filtros solares con base en hierro en ventanas

    Energy Technology Data Exchange (ETDEWEB)

    Chavez Galan, Jesus

    2003-07-01

    termico generado al interior de las edificaciones por las inadecuadas propiedades de los materiales de construccion, se desarrollaron en este trabajo filtros solares con base en hierro por medio de los cuales se logra un control selectivo de la radiacion solar que se transmite a traves de las ventanas. Estos filtros solares consisten en peliculas delgadas de FeO depositadas sobre sustratos de vidrio cal-sosa (el mas usado en nuestro pais para las edificaciones) de 600x300x3 mm, por medio de la tecnica de sputtering asistida con radiofrecuencia y magnetrones planos, partiendo de un blanco de hierro puro de 127x254 mm y usando un plasma de argon. Para obtener el grado de oxidacion deseado en el hierro, pequenas muestras (45 x 22 mm) fueron sometidas a un proceso de calentamiento en una atmosfera reductora constituida de 50% H{sub 2} + 50% N{sub 2}, durante un periodo de tiempo de 10 minutos a una temperatura de 400 C. Los filtros solares con base en FeO presentan una transmisividad de 30.2% para el intervalo visible del espectro electromagnetico (radiacion con longitud de onda de 380-780 nm), y de 39.9% para el infrarrojo cercano (radiacion con longitud de onda de 780-2500 nm); mientras que su reflectividad es de 17.5 y 19%, para los intervalos visibles e infrarrojo cercano del espectro electromagnetico respectivamente. Se realizo una simulacion, a traves del software Energy 10, del comportamiento energetico de una casa-habitacion cuando utilizan en las ventanas vidrios simples (una lamina) tipo cal-sosa, asi como tambien cuando esta misma edificacion usa en las ventanas los filtros solares con base en FeO desarrollados. Ambos casos se comparan obteniendose asi los posibles ahorros de energia por el uso de dichos filtros solares en las ventanas. Las simulaciones fueron llevadas a cabo para diferentes localidades del pais, obteniendose que los filtros solares con base en FeO desarrollados, permiten ahorros de energia principalmente por concepto de acondicionamiento de aire

  18. Technology Equipment Rooms.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Examines telecommunications equipment room design features that allow for growth and can accommodate numerous equipment replacements and upgrades with minimal service disruption and with minimal cost. Considerations involving the central hub, power and lighting needs, air conditioning, and fire protection are discussed. (GR)

  19. 'The pump was a saviour for me.' Patients' experiences of insulin pump therapy.

    Science.gov (United States)

    Garmo, A; Hörnsten, Å; Leksell, J

    2013-06-01

    The present study formed part of a larger study examining the potential long-term effects of glycaemic control and treatment satisfaction in people with Type 1 diabetes mellitus who changed from multiple daily insulin injections to insulin pump therapy. Individuals (n = 46) who made the transition between May 1999 and February 2004 participated. The aim of the study was to describe experiences of the impact of insulin pump therapy in adults with Type 1 diabetes mellitus after > 5 years' use of an insulin pump. During spring 2009, 16 of the individuals were interviewed through a narrative approach on the effects of insulin pump therapy on daily life. The interviews were analysed using content analysis. The overarching theme revealed that insulin pump therapy was experienced as both a shackle and a lifeline. Six sub-themes emerged: subjected vs. empowered; dependent vs. autonomous; vulnerable vs. strengthened; routinized vs. flexible; burdened vs. relieved; and stigmatized vs. normalized. Users of insulin pump therapy have different views about and experience of having used the technical equipment over years. Both positive and negative views emerged. However, it is difficult to identify any general trends that cover all views and can predict which individuals will be able to manage pump therapy in the best way. Even so, the sub-themes and theme that emerged could be used by physicians and diabetes specialist nurses when counselling and planning educational programmes aimed at supporting self-management among people with insulin pump treatment. © 2013 The Authors. Diabetic Medicine © 2013 Diabetes UK.

  20. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  1. 46 CFR 34.10-5 - Fire pumps-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps-T/ALL. 34.10-5 Section 34.10-5 Shipping COAST... § 34.10-5 Fire pumps—T/ALL. (a) Tankships shall be equipped with independently driven fire pumps in accordance with table 34.10-5(a). Table 34.10-5(a)—Fire Pumps Size vessel, L.O.A. (feet) Over— Not...

  2. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  3. Survey of industrial coal conversion equipment capabilities: rotating components

    Energy Technology Data Exchange (ETDEWEB)

    Williams, W. R.; Horton, J. R.; Boudreau, W. F.; Siman-Tov, M.

    1978-04-01

    At the request of the Major Facilities Project Management Division of the Energy Research and Development Administration, Fossil Energy Division, a study was undertaken to determine the capabilities of U.S. industry to supply the rotating equipment needed for future coal conversion facilities. Furthermore, problem areas were to be identified and research and development needs determined for producing advanced designs of the required equipment: Pumps, compressors, hydraulic turbines, and gas expanders. It has been concluded that equipment for essentially all clean-stream applications likely to be encountered in coal conversion facilities is generally available except high-pressure oxygen compressors. These oxygen compressors as well as slurry pumps need to be developed or significantly upgraded. Also, fans and blower for dirty-gas streams need developmental work, as do expanders for high-temperature service. Hydraulic turbines, which were not specified but which might be used for slurry applications in future coal conversion plants, are not available.

  4. Development of in-situ testing equipment of rock and soil thermophysical properties

    Institute of Scientific and Technical Information of China (English)

    Qinghua WANG; Youhong SUN; Qiang LI

    2008-01-01

    A mobile in-situ testing equipment used to detect geotechnical thermophysical properties was developed. The equipment is composed of a heat pump, frequency pumps, an electric tee joint regulator valve, some sensors, an electric control system, data acquisition and control system, which can do tests under the condition of extracting and storing subsurface heat. Applying the line source and the cylinder source heat transfer model, and combining the parameters estimation, the average thermophysical property parameters of rock and soil will be calculated, which provides the basis for designing the ground source heat pump systems.

  5. Piezoelectric diffuser/nozzle micropump with double pump chambers

    Institute of Scientific and Technical Information of China (English)

    Wei WANG; Ying ZHANG; Li TIAN; Xiaojie CHEN; Xiaowei LIU

    2008-01-01

    To eliminate check valve fatigue and valve clogging, diffuser/nozzle elements are used for flow rec-tification in a valveless diffuser/nozzle micropump instead of valves. However, the application of this type of micro-pump is restricted because of its pulsating or periodic flow and low pump flux. In this paper, a diffuser/nozzle Si/ Glass micropump with two pump chambers by IC and MEMS technology is designed. The fabrication process requires only one mask and one etch step, so that the fabrication has the advantages of low cost, short proces-sing period, and facilitation of miniaturization. The pump is equipped with a glass cover board so as to conveniently observe the flow status. Pump-chambers and diffuser ele-ments are fabricated by the anisotropic KOH-etch tech-nique on the silicone substrate, and the convex corner is designed to compensate for an anisotropic etch. The driv-ing force of the micropump is produced by the PZT piezo-electric actuator, The pump performance with both actuators actuated in anti- or same-phase mode is also researched. The result indicates that the micropump achieves great performance with the actuators working at anti-phase. This may be because the liquid flows stead-ily, pulse phenomenon is very weak, and the optimal working frequency, pump back pressure, and flow rate are both double that of the pump driven in same-phase.

  6. Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

    Science.gov (United States)

    Baker, David (Inventor)

    1998-01-01

    A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

  7. On-line PWR RHR pump performance testing following motor and impeller replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiMarzo, J.T.

    1996-12-01

    On-line maintenance and replacement of safety-related pumps requires the performance of an inservice test to determine and confirm the operational readiness of the pumps. In 1995, major maintenance was performed on two Pressurized Water Reactor (PWR) Residual Heat Removal (RHR) Pumps. A refurbished spare motor was overhauled with a new mechanical seal, new motor bearings and equipped with pump`s `B` impeller. The spare was installed into the `B` train. The motor had never been run in the system before. A pump performance test was developed to verify it`s operational readiness and determine the in-situ pump performance curve. Since the unit was operating, emphasis was placed on conducting a highly accurate pump performance test that would ensure that it satisfied the NSSS vendors accident analysis minimum acceptance curve. The design of the RHR System allowed testing of one train while the other was aligned for normal operation. A test flow path was established from the Refueling Water Storage Tank (RWST) through the pump (under test) and back to the RWST. This allowed staff to conduct a full flow range pump performance test. Each train was analyzed and an expression developed that included an error vector term for the TDH (ft), pressure (psig), and flow rate (gpm) using the variance error vector methodology. This method allowed the engineers to select a test instrumentation system that would yield accurate readings and minimal measurement errors, for data taken in the measurement of TDH (P,Q) versus Pump Flow Rate (Q). Test results for the `B` Train showed performance well in excess of the minimum required. The motor that was originally in the `B` train was similarly overhauled and equipped with `A` pump`s original impeller, re-installed in the `A` train, and tested. Analysis of the `A` train results indicate that the RHR pump`s performance was also well in excess of the vendors requirements.

  8. The Importance of Computational Modeling of Large Pumping Stations

    Directory of Open Access Journals (Sweden)

    S. M. Bozh'eva

    2015-01-01

    Full Text Available The article presents main design and structure principles of pumping stations. It specifies basic requirements for the favorable hydraulic operation conditions of the pumping units. The article also describes the designing cases, when computational modeling is necessary to analyse activity of pumping station and provide its reliable operation. A specific example of the large pumping station with submersible pumps describes the process of computational modeling of its operation. As the object of simulation was selected the underground pumping station with a diameter of 26 m and a depth of 13 m, divided into two independent branches, equipped with 8 submersible pumps. The objective of this work was to evaluate the effectiveness of the design solution by CFD methods, to analyze the design of the inlet chamber, to identify possible difficulties with the operation of the facility. In details are described the structure of the considered pumping station and applied computational models of physical processes. The article gives the detailed formulation of the task of simulation and the methods of its solving and presents the initial and boundary conditions. It describes the basic operation modes of the pumping station. The obtained results were presented as the flow patterns for each operation mode with detailed explanations. Data obtained as a result of CFD, prove the correctness of the general design solutions of the project. The submersible pump operation at the minimum water level was verified, was confirmed a lack of vortex formation as well as were proposed measures to improve the operating conditions of the facility. In the inlet chamber there are shown the stagnant zones, requiring separate schedule of cleaning. The measure against floating debris and foam was proposed. It justifies the use of computational modeling (CFD for the verifying and adjusting of the projects of large pumping stations as a much more precise tool that takes into account

  9. 33 CFR 157.222 - Pump and piping arrangements.

    Science.gov (United States)

    2010-07-01

    ... OIL IN BULK Dedicated Clean Ballast Tanks on Tank Vessels Design and Equipment § 157.222 Pump and piping arrangements. (a) Dedicated clean ballast tanks must be connected to the least practicable: (1... each dedicated clean ballast tank must be arranged so that oily water does not enter any...

  10. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  11. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  12. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  13. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  14. Underground pumped hydroelectric storage

    Science.gov (United States)

    Allen, R. D.; Doherty, T. J.; Kannberg, L. D.

    1984-07-01

    Underground pumped hydroelectric energy storage was conceived as a modification of surface pumped storage to eliminate dependence upon fortuitous topography, provide higher hydraulic heads, and reduce environmental concerns. A UPHS plant offers substantial savings in investment cost over coal-fired cycling plants and savings in system production costs over gas turbines. Potential location near load centers lowers transmission costs and line losses. Environmental impact is less than that for a coal-fired cycling plant. The inherent benefits include those of all pumped storage (i.e., rapid load response, emergency capacity, improvement in efficiency as pumps improve, and capacity for voltage regulation). A UPHS plant would be powered by either a coal-fired or nuclear baseload plant. The economic capacity of a UPHS plant would be in the range of 1000 to 3000 MW. This storage level is compatible with the load-velocity requirements of a greater metropolitan area with population of 1 million or more.

  15. Chiral brownian heat pump.

    Science.gov (United States)

    van den Broek, M; Van den Broeck, C

    2008-04-04

    We present the exact analysis of a chiral Brownian motor and heat pump. Optimization of the construction predicts, for a nanoscale device, frequencies of the order of kHz and cooling rates of the order of femtojoule per second.

  16. Chiral Brownian heat pump

    OpenAIRE

    Van Den Broek, Martijn; Van Den Broeck, Christian

    2007-01-01

    We present the exact analysis of a chiral Brownian motor and heat pump. Optimization of the construction predicts, for a nanoscale device, frequencies of the order of kHz and cooling rates of the order of femtojoule per second.

  17. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  18. Some comments on air source heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Haukaas, H.T. (Norges tekniska hoegskola, Trondheim (Norway)). Institutt for kuldeteknikk

    1982-02-01

    Some vital conditions regarding air/water heat pumps are analyzed by use of computer simulators of a middle sized heat pump system. Heat pumps, and specially air source units, should always be used in combination with conventional heating equipment for peak load supply. (Bivalent systems). The economic optimum heat pump capacity compared to system design load is strongly related to the climate. At typical coastal conditions a ratio of 60-70 per cent is found favourable, while 40-50 per cent will be the correct choice for Norwegian inland area. Analysis of the evaporator shows that it should be designed for 120-130 W/m/sup 2/ specific load and 2-2.2 m/s inlet air velocity, which is well below common practice in designing standard air coolers. The condenser LMTD (logaritmic mean temperature difference) should be chosen about 4 degrees C, while the corresponding 'sellers optimum' is calculated to app. 8.5 degrees C. The difference in total heating costs between systems fully designed according to 'sellers optimum' and 'buyers optimum' respectively is found to be about 0.01 Nkr/kWh.

  19. Open-source syringe pump library.

    Science.gov (United States)

    Wijnen, Bas; Hunt, Emily J; Anzalone, Gerald C; Pearce, Joshua M

    2014-01-01

    This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD) software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications.

  20. Open-source syringe pump library.

    Directory of Open Access Journals (Sweden)

    Bas Wijnen

    Full Text Available This article explores a new open-source method for developing and manufacturing high-quality scientific equipment suitable for use in virtually any laboratory. A syringe pump was designed using freely available open-source computer aided design (CAD software and manufactured using an open-source RepRap 3-D printer and readily available parts. The design, bill of materials and assembly instructions are globally available to anyone wishing to use them. Details are provided covering the use of the CAD software and the RepRap 3-D printer. The use of an open-source Rasberry Pi computer as a wireless control device is also illustrated. Performance of the syringe pump was assessed and the methods used for assessment are detailed. The cost of the entire system, including the controller and web-based control interface, is on the order of 5% or less than one would expect to pay for a commercial syringe pump having similar performance. The design should suit the needs of a given research activity requiring a syringe pump including carefully controlled dosing of reagents, pharmaceuticals, and delivery of viscous 3-D printer media among other applications.

  1. The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, A. [Universidad Nacional Autonoma de Mexico (Mexico); Islas, J [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico); Arriola, A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    cantidad representa un porcentaje importante de los gastos totales del hospital (29.367 millones de dolares) es importante determinar posibilidades tecnico - economicas de ahorro de energia termica del hospital. El HGZ N 1 - IMSS Ags. Esta ubicado en un conjunto mas amplio en donde se localizan las unidades del IMSS, tales como, la lavanderia regional, la unidad deportiva, el centro de seguridad social, la unidad de medicina familiar N 1 y el hospital. Sin embargo a partir de las instalaciones electricas y de suministro de vapor y agua caliente del hospital se distribuyen los fluidos electricos y termicos de todo este conjunto. Debido a esta situacion, en este trabajo nos referiremos al consumo global del conjunto del IMSS de Aguascalientes en donde el hospital es el principal consumidor de energia termica. En el presente trabajo calcularemos el potencial tecnico - economico de ahorro de energia termica del conjunto del IMSS a traves de la tecnica termodinamica de punto de pliegue o tecnica pinch.

  2. Remotely Adjustable Hydraulic Pump

    Science.gov (United States)

    Kouns, H. H.; Gardner, L. D.

    1987-01-01

    Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.

  3. Velocity selective optical pumping

    OpenAIRE

    Aminoff, C. G.; Pinard, M.

    1982-01-01

    We consider optical pumping with a quasi monochromatic tunable light beam, in the low intensity limit where a rate equation regime is obtained The velocity selective optical pumping (V.S.O.P.) introduces a correlation between atomic velocity and internal variables in the ground (or metastable) state. The aim of this article is to evaluate these atomic observables (orientation, alignment, population) as a function of velocity, using a phenomenological description of the relaxation effect of co...

  4. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  5. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  6. Reliable Electronic Equipment

    Directory of Open Access Journals (Sweden)

    N. A. Nayak

    1960-05-01

    Full Text Available The reliability aspect of electronic equipment's is discussed. To obtain optimum results, close cooperation between the components engineer, the design engineer and the production engineer is suggested.

  7. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    1995-01-01

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the biocompati

  8. Pumping a playground swing.

    Science.gov (United States)

    Post, Auke A; de Groot, Gert; Daffertshofer, Andreas; Beek, Peter J

    2007-04-01

    In mechanical studies of pumping a playground swing, two methods of energy insertion have been identified: parametric pumping and driven oscillation. While parametric pumping involves the systematic raising and lowering of the swinger's center of mass (CM) along the swing's radial axis (rope), driven oscillation may be conceived as rotation of the CM around a pivot point at a fixed distance to the point of suspension. We examined the relative contributions of those two methods of energy insertion by inviting 18 participants to pump a swing from standstill and by measuring and analyzing the swing-swinger system (defined by eight markers) in the sagittal plane. Overall, driven oscillation was found to play a major role and parametric pumping a subordinate role, although the relative contribution of driven oscillation decreased as swinging amplitude increased, whereas that of parametric pumping increased slightly. Principal component analysis revealed that the coordination pattern of the swing-swinger system was largely determined (up to 95%) by the swing's motion, while correlation analysis revealed that (within the remaining 5% of variance) trunk and leg rotations were strongly coupled.

  9. La Función de la Auditoría Interna en las Cajas de Ahorros Españolas

    Directory of Open Access Journals (Sweden)

    Horacio Molina Sánchez

    2007-06-01

    Full Text Available Hoy día la función de auditoría interna es clave en el esquema de gobierno corporativo de las entidades financieras. Esta investigación tiene dos objetivos. En primer lugar, pretendemos describir el grado de cumplimiento de las recomendaciones del Comité de Basilea por parte de las cajas de ahorros españolas en un momento anterior a la regulación de aspectos sustanciales del gobierno de estas entidades (como por ejemplo, la figura del comité de auditoría por parte de la Ley Financiera. En segundo lugar, identificamos las diferencias existentes entre las entidades atendiendo a su dimensión. El método empleado ha sido una encuesta a las entidades, obteniéndose respuesta de 42 de las 47 entidades. Los resultados obtenidos presentan la situación de los departamentos de auditoría interna y confirman que, en un número significativo de aspectos, la dimensión de las entidades influye en el grado de implantación de los estándares emitidos por el Comité de Basilea.Nowadays, the internal audit function is critical in the corporate governance framework of financial institutions. Our research’s objective has to objectives. First, we try to describe the implementation level of Basle Committee’s recommendations in the Spanish saving banks before an important regulation over corporate governance has been issued in Spain (for instance, the figure of audit committee through the Financial Law. Second, we assess the differences between entities considering their dimmension. We have carried out a survey to saving banks, obtaining a response from 42 out of 47 entities. Our results show the situation of internal audit departments and confirm that, in a significative number of cases, entities’ dimmension affects the level of implementation of the Basel Committee’s standards.

  10. Energy saving avoiding the centrifugal motor-compressors air vents discharge to the surrounding atmosphere; Ahorro de energia evitando venteo de aire a la atmosfera en motocompresores centrifugos

    Energy Technology Data Exchange (ETDEWEB)

    Serrano, Alex [Compressor Controls Corporation, Houston, TX (United States)

    1996-12-31

    The motor-compressors are a key part of the industrial processes. The reliability and efficient operation of a compressor is critical. The surge phenomenon is a threat in the reliability of a compressor and therefore for the process. Surge, in a centrifugal compressor is defined as a dramatic flow and pressure drop, including back-flow. This is always a significant process disturbance. Continuous surge results into costly process shutdowns and mechanical damages. To prevent surge, and control the discharge pressure with simple or obsolete controls it is needed to vent air to the surrounding atmosphere. This form of control is very inefficient and costly. An advanced control with leading technology, besides providing an economical value preventing surge damages, offers substantial energy saving reducing or eliminating the venting of air to the atmosphere. [Espanol] Los motocompresores son un aparte clave de los procesos industriales. La confiable y eficiente operacion de un compresor es critica. El fenomeno de surge es una amenaza a la confiabilidad de un compresor y por lo tanto del proceso. El surge en un compresor centrifugo es definido como una dramatica caida de flujo y presion, incluyendo flujo inverso. Esto es siempre un significante disturbio del proceso. El surge continuo resulta en costosos paros de proceso y danos mecanicos. Para prevenir el surge y controlar la presion de descarga con controles simples u obsoletos, es necesario ventear aire a la atmosfera. Esta forma de control es muy ineficiente y costosa. Un control avanzado con tecnologia de punta ademas de proveer valor economico previniendo danos por surge, provee sustanciales ahorros de energia reduciendo o eliminando el venteo de aire a la atmosfera.

  11. Los Sistemas de Transferencia Interna de Fondos: Su Aplicación en las Cajas de Ahorros y en las Cajas Rurales españolas

    Directory of Open Access Journals (Sweden)

    Pilar Ibarrondo Dávila

    2004-12-01

    Full Text Available El entorno competitivo de las entidades de depósito ha sufrido fuertes cambios durante las dos últimas décadas, y en la actualidad se caracteriza por una fuerte rivalidad entre las empresas del sector. En este contexto, las entidades bancarias deben dotarse de sistemas de información ágiles y flexibles que les permitan dar respuesta a las nuevas necesidades gerenciales y a las actuales exigencias de la dirección estratégica. Desde esta perspectiva, en el presente trabajo se estudian las características de los distintos sistemas de transferencia interna de fondos aplicables en las entidades bancarias, procediendo a un análisis comparativo de los mismos, y, posteriormente, se presentan los principales rasgos que caracterizan a los sistemas de transferencia de fondos correspondientes a las cajas de ahorros y a las cajas rurales, a partir de los resultados obtenidos de una encuesta realizada en dichas entidades. The competitive environment of monetary financial institutions has undergone great changes over the last two decades, and at present is characterized by strong competition among the companies of the sector. In this context, the monetory financial institutions should be endowed with agile and flexible information systems that allow them to respond to the new managerial necessities and the current demands of Strategic Management. Thus, in this paper, first we analyse the characteristics of the different funds-tranfer- pricing methods applicable in the banks and go on to carry out a comparative analysis of the former. Secondly, we present the main features that characterize the funds-transfer-pricing methods in Spanish Savings Banks and Spanish Rural Banks, based on the results obtained from a survey carried out among these companies.

  12. Aplicación electrónica para el ahorro de energía eléctrica utilizando una energía alternativa

    Directory of Open Access Journals (Sweden)

    Juan Carlos Cruz-Ardila

    2013-01-01

    Full Text Available El artículo presenta un trabajo orientado a disminuir el consumo de energía eléctrica entregada por la red eléctrica convencional, a través del aprovechamiento de la energía solar fotovoltaica. Se propone el diseño de un sistema de transferencia electrónica que facilita el uso de la energía eléctrica DC proveniente del panel solar, suprimiendo de esta manera, la utilización del inversor de voltaje, comúnmente usado en este tipo de aplicaciones y que eleva el costo de utilización de la energía solar. Se da a conocer inicialmente una revisión del estado del arte, que permite contextualizar el problema resuelto a partir de una energía renovable como la fotovoltaica, destacándose que actualmente España es el país con mayor desarrollo en este tema. Luego, se muestra el desarrollo secuencial del sistema de alimentación y la transferencia electrónica, haciendo una descripción de las variables identificadas y explicación, con el uso de diagramas de flujo, del sistema embebido implementado. También se da una descripción de los dispositivos usados tal como el sensor de corriente, la regulación y la rectificación. Se muestra el esquemático de la transferencia implementada. Finalmente, se revelan los resultados y las pruebas operacionales realizadas al sistema para demostrar la funcionalidad de la aplicación electrónica en el ahorro de la energía eléctrica utilizando una energía alternativa.

  13. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...... is considered as extruded profiles are inadequate for compact designs. An optimal pin fin shape and configuration is sought also taking manufacturing costs into consideration. Standard methods for geometrical modeling and thermal analysis are applied....

  14. Diseño de un modelo de gestión basado en responsabilidad social para el manejo de riesgos en cooperativas de ahorro y crédito

    OpenAIRE

    Proaño Castillo, Jenny Catalina

    2015-01-01

    1. Introducción.-- 2. Planteamiento de la Propuesta de Trabajo.-- 3. Marco Teórico.-- 4. Metodología.-- 5. Resultados.-- 6. Conclusiones y Recomendaciones El presente trabajo es el diseño de un modelo de gestión basado en responsabilidad social para el manejo de riesgos para uso de Cooperativas de Ahorro y Crédito, apoyado en la necesidad de que las Cooperativas gestionen su accionar administrativo financiero fundamentado en principios éticos y socialmente responsables e implementen mecani...

  15. Bancos Cooperativos y Sociedades de Ahorro y Crédito en El Salvador: modelo de supervisión prudencial y análisis empírico del coeficiente de solvencia

    OpenAIRE

    Hernández, Ana Verónica

    2013-01-01

    Estudio bibliográfico empírico, con el que se presenta una propuesta de supervisión para la superintendencia financiera de El Salvador, que incluye requisitos mínimos a considerar por el auditor, tomando como base Basilea II, III y siguiendo el Modelo OSFI de Canadá. Además se presenta un estudio empírico sobre los determinantes del coeficiente patrimonial en bancos cooperativos y sociedades de ahorro y crédito de El Salvador. Economía Financiera y Contabilidad Máster en Investigación ...

  16. Conclusiones de las Ponencias y Debates del Coloquio Internacional sobre Ahorro de Energía celebrado en Budapest, organizado por la Sección Húngara de la Europrefab

    Directory of Open Access Journals (Sweden)

    Aguirre de Iraola, Fernando

    1980-03-01

    Full Text Available Durante los días 10 y 11 de abril, el doctor Arquitecto F. Aguirre, director del ITEcc, estvuo en Budapest para presidir el Coloquio Internacional sobre «Ahorro de energía en la edificación», que había sido organizado por la sociedad europea para la promoción de la industrialización de la construcción, (EUROPREFAB, de la cual el profesor Aguirre es presidente.

  17. The use of reflecting paints on building`s roofs for energy saving; Uso de pinturas reflejantes en los techos de las edificaciones para el ahorro de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Valera Negrete, Jose Adrian [Programa de Ahorro de Energia del Sector Electrico (PAESE), Comision Federal de Electricidad, Mexico, D. F. (Mexico); Sanchez Soto, Ramon [Facultad de Ingenieria, Departamento de Termoenergia de la UNAM, Mexico, D. F. (Mexico)

    1998-12-31

    This paper shows the effects of the use of reflecting paints in different colors on the buildings roofs and the results in energy saving obtained in a field test carried on in Monterrey, Nuevo Leon State of Mexico using aluminum paint. [Espanol] El presente trabajo muestra los efectos del uso de pinturas reflejantes de diferentes colores en los techos de edificaciones, y los resultados de ahorro de energia electrica obtenidos en una prueba de campo efectuada en Monterrey, Nuevo Leon, Mexico, utilizando pintura de aluminio.

  18. Pumping Optimization Model for Pump and Treat Systems - 15091

    Energy Technology Data Exchange (ETDEWEB)

    Baker, S.; Ivarson, Kristine A.; Karanovic, M.; Miller, Charles W.; Tonkin, M.

    2015-01-15

    Pump and Treat systems are being utilized to remediate contaminated groundwater in the Hanford 100 Areas adjacent to the Columbia River in Eastern Washington. Design of the systems was supported by a three-dimensional (3D) fate and transport model. This model provided sophisticated simulation capabilities but requires many hours to calculate results for each simulation considered. Many simulations are required to optimize system performance, so a two-dimensional (2D) model was created to reduce run time. The 2D model was developed as a equivalent-property version of the 3D model that derives boundary conditions and aquifer properties from the 3D model. It produces predictions that are very close to the 3D model predictions, allowing it to be used for comparative remedy analyses. Any potential system modifications identified by using the 2D version are verified for use by running the 3D model to confirm performance. The 2D model was incorporated into a comprehensive analysis system (the Pumping Optimization Model, POM) to simplify analysis of multiple simulations. It allows rapid turnaround by utilizing a graphical user interface that: 1 allows operators to create hypothetical scenarios for system operation, 2 feeds the input to the 2D fate and transport model, and 3 displays the scenario results to evaluate performance improvement. All of the above is accomplished within the user interface. Complex analyses can be completed within a few hours and multiple simulations can be compared side-by-side. The POM utilizes standard office computing equipment and established groundwater modeling software.

  19. Examen de auditoría integral al área de Recursos Humanos de la Cooperativa de Ahorro y Crédito El Sagrario Ltda. , correspondiente al periódo 01 de enero al 31 de diciembre 2012

    OpenAIRE

    2014-01-01

    El presente trabajo, se desarrolla en la Cooperativa de Ahorro y Crédito El Sagrario Ltda., específicamente en el proceso de Talento Humano que involucra: actividades de selección, administración de nómina, capacitación y desvinculación. El objetivo principal, será el realizar un examen de auditoría integral al proceso de Talento Humano de la Cooperativa de Ahorro y Crédito El Sagrario Ltda., correspondiente al periodo 01 de Enero al 31 de Diciembre 2012. Para el desarrollo del examen ...

  20. Energy saving with heat pumps in indoor swimming pools; Energiebesparing met warmtepompen in overdekte zwembaden

    Energy Technology Data Exchange (ETDEWEB)

    Langreck, J. [Colibri, Vaals (Netherlands)

    1997-01-01

    The article is based on the results of a study in which heat pumps and heat recovery equipment for indoor swimming pools are compared. By means of an average, reference indoor swimming pool the effects of energy savings and costs of different combinations of equipment are compared. It is concluded that more energy can be saved by a heat pump than by a heat recovery installation, although the payback period is longer for heat pumps. In all cases, an individual optimization of the total system for a specific swimming pool is decisive for the success of the energy saving investment costs. 3 figs., 1 ill., 2 tabs.

  1. 46 CFR 32.50-1 - Cargo pumps for tank vessels constructed on or after November 10, 1936-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo pumps for tank vessels constructed on or after... TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Pumps, Piping, and Hose for Cargo Handling § 32.50-1 Cargo pumps for tank vessels constructed on or after November 10, 1936—TB/ALL. On...

  2. 46 CFR 32.50-25 - Cargo pumps and piping on tank vessels constructed prior to November 10, 1936-TB/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo pumps and piping on tank vessels constructed prior... SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Pumps, Piping, and Hose for Cargo Handling § 32.50-25 Cargo pumps and piping on tank vessels constructed prior to November 10,...

  3. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  4. Saving 50% of energy in air conditioning and refrigeration; 50% de ahorro de energia en aire acondicionado y refrigeracion

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez De la Fuente, Rodolfo Javier [Instituto para la Proteccion Ambiental de Nuevo Leon-CAINTRA, Nuevo Leon (Mexico); Bolado Tamez, Jaime Antonio [Industrias AlEn S. A. de C. V., Monterrey (Mexico)

    1998-12-31

    Due to the fact that the air conditioning systems represent up to 70% of the energy consumption in our buildings, to the constant raise of the electric tariffs and to the increment of temperatures in Nuevo Leon State, as well as the restrictions on the use of some refrigerant fluids because of its potential damage to the ozone layer (Montreal Protocol) and the preferential use of refrigerants with low global heating potential (Kioto Protocol). The Camara de la Industria de la Transformacion de Nuevo Leon (Nuevo Leon`s Transformation Industry Chamber) through the Instituto para la Proteccion Ambiental de Nuevo Leon (Nuevo Leon`s Institute for Environmental Protection), create the program ECO-REFRIGERATION whose three missions are: Increase the efficiency of air conditioning and refrigeration equipment, promote the substitution of refrigerants and extend the benefits of these projects to the community in general. [Espanol] Debido a que los sistemas de climatizacion representan hasta el 70% de consumo energetico en nuestros inmuebles, al constante incremento de las tarifas electricas, el incremento de las temperaturas en Nuevo Leon, asi como la restriccion del uso de algunos refrigerantes por su potencial de dano de la capa de ozono (Protocolo de Montreal) y el uso preferente de refrigerantes con bajo potencial de calentamiento global (Protocolo de Kioto), la Camara de la Industria de la Transformacion de Nuevo Leon a traves del Instituto para la Proteccion Ambiental de Nuevo Leon crean el Programa ECO-REFRIGERACION cuyas tres misiones son: Incrementar la eficiencia de los equipos de aire acondicionado y refrigeracion, promover la sustitucion de refrigerantes y extender los beneficios de este proyecto a la comunidad en general.

  5. Reversible pumped hydro - benefits and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Torbjoern K.; Walseth, Eve C.

    2010-07-01

    Full text: The Norwegian hydro power system is dominated with high head turbines, Pelton and Francis with high capacity in the reservoirs. Originally they were built for secure energy supply. In the system there are also reversible pump turbine (RPT) plants where in times with spare energy, made it possible to pump water from the lower reservoir to the higher. Again the idea was to secure energy supply, which meant pumping in early autumn to fill the reservoirs for winter. In the recent years, a more active use of the RPT plants has been actualized. The free market made price difference between night and day interesting, hence a more frequent pumping was desirable. In the coming years, new-renewable energy sources will utterly enhance a more active use of the RPT plants. More active use of the RPT plants means more frequent starts and stops, both in pumping and in turbine mode. There are a lot of challenges in adopting a new strategy for operating the machinery. More effective start equipment is required. The machinery will be exposed to more frequent dynamic loads; the turbines will be run at part- and full load. The existing RPT plants are connected to huge reservoirs. That means the RPTs are not only for short sighted power regulations, as many RPT-plants in Europe, but are also capable for a substantial energy production. In Norway, the nature is very suitable for RPT plants, both in connection with existing power plants, were reservoirs and conduits are already established, and standing alone with a minimum of energy production. RPTs are, as a design, a compromise between effective generating and stable as well as effective pumping. Stable pumping often results in very steep flow-speed characteristics when operating as a turbine. When dealing with hydraulic transients these characteristics cause a higher change in flow and torque leading to instability during start-up and possible off-design operation point. The instability slows down the synchronization

  6. Electronic Unit Pump Test Bench Development and Pump Properties Research

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; HUANG Ying; ZHANG Fu-jun; ZHAO Chang-lu

    2006-01-01

    A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test bot h mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is d one. Experimental results show that the injection quantity is linear with the de livery angle. The quantity change rate is 15% when fuel temperature increases 30℃. The delivery quantity per cycle increases 30mg at 28V drive voltage. T he average delivery difference for two same type pumps is 5%. Test results show that the bench can be used for unit pump verification.

  7. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  8. Assessment of high-head turbomachinery for underground pumped hydroelectric storage plants

    Science.gov (United States)

    Tam, S. W.; Frigo, A. A.; Blomquist, C. A.

    Underground pumped hydroelectric storage (UPHS) plants equipped with advanced reversible pump turbines for operating heads from 500 to 1500 m are discussed in terms of cost efficiency. It is found that the use of advanced machinery shifts the minimum UPHS plant cost to the head range 1200-1500 m. The interactive effects of pump-turbine efficiencies and charge/discharge ratios are examined. It is shown that under certain conditions, a pump-turbine option with a higher charge-discharge ratio at the expense of somewhat lower operating efficiency may be desirable.

  9. Energy saving based on the reduction of losses in the transmission and distribution of the power generated incrementing the transmission capacities by means of the use of direct current; Ahorro de energia basado en la reduccion de perdidas en la transmision y redistribucion de la generacion al ampliar las capacidades de transmision por medio del empleo de la transmision en corriente directa

    Energy Technology Data Exchange (ETDEWEB)

    Meraz Ateca, E.; Alanis Rodriguez, J.P.; Salinas Barrera, H.; Arechiga Rodriguez, L.D.; Guerrero Garza, J.J. [Comision Federal de Electricidad (CFE) (Mexico)

    1995-12-31

    This paper proposes the use of the technology for the transmission of direct current that provides a saving in losses in the order of 50% in transmitting the same power as the line energized with A.C., as well as having a larger transmission capacity, since the limiting factor in operating with D.C. is given by its thermal capacity. The cost of the terminal stations is high in comparison with that of A.C., therefore it should be compensated with the benefits of the D.C. transmission. The project proposal is as a first option, to utilize the 400 KV power lines of Carbon II-Lampazos-Escobedo as a single line in Direct Current, reducing by this means about 12% of the existing losses and increasing the existing transmission capacity from the coal power stations of Rio Escondido and Carbon II. For 1995 it will be Also available 2600 MW of generating capacity and practically four circuits of 400 KV to transmit power to the Monterrey Metropolitan Area, reaching this site approximately 1500 MW. It is proposed to transmit 750 MW through the D.C. line in bi-polar way. The investment will consist only in the two conversion stations, that for a power capacity of 750 MW will be in the order of 103 millions of dollars. This cost includes the switching equipment for A.C., filters for harmonics, banks of VARS to compensate for a unit power factor, transformers, converters, ground electrodes, communications, buildings, land site preparation, project management costs and the preliminary and engineering studies costs. These costs can be reduced in accordance with the detail studies, for instance: there is enough capacity in Vars in the generating units, the transmission is always one-way, the utilization of diodes instead of thyristors. For the established conditions, there is a reduction of 10 MW, a 23.82 million dollars saving, and besides a larger Also available transmission capacity in the order of 500 MW, additionally, when operating with direct current, equipment from the

  10. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  11. La financiación de las oligarquías provinciales en el apogeo y crisis del negocio inmobiliario en España: una reflexión sociológica sobre las cajas de ahorros

    Directory of Open Access Journals (Sweden)

    José Manuel Rodríguez Acevedo

    2011-10-01

    Full Text Available El hundimiento, en el contexto de la crisis internacional del capitalismo, del modelo económico basado en el “ladrillo” y la especulación urbanística −además de en el turismo− ha puesto sobre la mesa el problema de las cajas de ahorros. En este artículo se repasa el papel destacado que estas peculiares entidades financieras han venido jugado en la financiación del boom inmobiliario de las últimas décadas en España. Creemos que no se puede llegar al fondo del asunto sin comprender la naturaleza histórica de unas fragmentadas oligarquías económicas y políticas de ámbito provincial y local, lideradas por promotores y grandes propietarios del suelo rústico y urbano, que han encontrado en las cajas de ahorros una privilegiada forma de financiación para los turbios y particulares negocios en los que se ha basado el tan alabado milagro económico español.

  12. Análisis de la relación entre los resultados sociales y económicos de las cajas de ahorros españolas: un caso de responsabilidad social corporativa

    Directory of Open Access Journals (Sweden)

    Laura Cabeza-García

    2010-10-01

    Full Text Available La obra social constituye uno de los ámbitos de aplicación de la responsabilidad social corporativa (RSC en el contexto de las cajas de ahorros. Por ello, a partir del marco teórico que explica la naturaleza de la relación entre la realización de actividades de índole social y los resultados financieros, el objetivo de este trabajo es analizar el efecto de la inversión en obra social sobre la performance de las cajas españolas. Tras aplicar un modelo dinámico de datos de panel (GMM los hallazgos encontrados sugieren, una vez controlado el problema de endogeneidad, una influencia negativa y significativa sobre el nivel de rentabilidad, tanto económica como financiera. Por tanto, nuestros resultados avalan la hipótesis del trade off en el sub-sector financiero de las cajas de ahorros españolas

  13. IRRIGATION STATION EQUIPMENT FOR PREVENTING THE USE OF LOW WATER QUALITY

    Directory of Open Access Journals (Sweden)

    Constantin Nicolescu

    2010-01-01

    Full Text Available In Romania the economically efficient irrigated area is estimated at 3.5 million hectares. On national scale there is nointegrated approach for monitoring the quantity and quality of the irrigation water, using adequate equipment at thepumping station. On international scale, in many countries the pumping stations are provided with equipment formonitoring, on real time, the quality or the pumped water and for warning about critical situations (emergencies.This paper describes a technical solution consisting of equipment which monitors the following parameters of waterpumped in irrigation systems: turbidity, pH, CE at 25 o C, Na+, Cl-. The lapse of time for monitoring is of 10 to 60 min.The main components are the following: the sampling pump (submersible the monitoring board, the repression pipe ofthe analyzed water. Warnings are made about values exceeding the programmed level for each monitored parameter,about the fact that the pump and agitator do not work or about any other source of damage.The technical solution and equipment were tested at a pumping station which uses water from Danube, in most casesmixed with water originating from drainage. Results showed a reduction of the total content of soluble salts from soiland of their negative impact upon the crops, a reduction of the degree of river alluvial deposits within the irrigationsystem and reduction of the energetic consumption required for pumping.

  14. The design and manufacture of the catalyst test equipment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. H.; Song, I. T. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-02-01

    The object of this report is to design and manufacture of the catalyst test equipment for removing tritium(H3) included in heavy water for the heavy water reactor. The design conditions of the reactor with the test equipment are summarized as follows 1) Flow rate : 336 l/min. 2) Pressure : 1.15kg/cm{sup 2}. 3) Maximum Temperature : 80 deg C. The test equipment is composed of the water jacket reactor, water equilibrator, heaters, condensers, tanks and pumps. As well as, it is composed of the water, hydrogen, helium, vacuum, emergency operation and control systems. This report will be used important data for the design and manufacture of the equipment for removing tritium. 30 tabs. (Author)

  15. Pulsed differential pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, G.N.; Bagautdinov, F.A.; Rybalov, S.V.

    1985-06-01

    A pulsed differential pumping system is described for extracting an electron beam from a shaping region at a pressure of 10/sup -5/ torr into a volume with a pressure of 10-100 torr. A fast valve is used with appropriate geometrical parameters to reduce the length of the outlet channel considerable while increasing its diameter. Test results are given. The pumping system has two sections which communicate one with the other and with the volume at the elevated pressure which is produced by gasdynamic nozzles.

  16. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  17. Sorption product heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Antonini, G.; Francois, O.; Gendarme, J.P.; Guilleminot, J.J.; Meunier, F.

    1988-07-15

    A continuous operating, and thus with enhanced performance, heat pump is presented. In this heat pump, the heat transfer between the hot source and the output system or network is realized through a solid adsorbent-refrigerant couple having endothermal desorption properties and exothermal adsorption or absorption properties. The sorption products are carried in a closed cycle movement between the two parts of the reactor. Each side of the reactor is assuming always the same function and the thermal inertia have to be overcome only when starting the reactor.

  18. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  19. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  20. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  1. Molecular heat pump.

    Science.gov (United States)

    Segal, Dvira; Nitzan, Abraham

    2006-02-01

    We propose a molecular device that pumps heat against a thermal gradient. The system consists of a molecular element connecting two thermal reservoirs that are characterized by different spectral properties. The pumping action is achieved by applying an external force that periodically modulates molecular levels. This modulation affects periodic oscillations of the internal temperature of the molecule and the strength of its coupling to each reservoir resulting in a net heat flow in the desired direction. The heat flow is examined in the slow and fast modulation limits and for different modulation wave forms, thus making it possible to optimize the device performance.

  2. Education Demonstration Equipment

    Science.gov (United States)

    Nagy, A.; Lee, R. L.

    2003-10-01

    The General Atomics fusion education program ``Scientist in the Classroom" (SIC) now in its sixth year, uses scientists and engineers to present plasma as a state of matter to students in the classroom. Using hands-on equipment, students see how magnets, gas pressure changes, and different gases are turned into plasmas. A piston, sealed volume, and vacuum chamber illuminate ideal gas laws. Liquid nitrogen is used to explore thermodynamic temperature effects and changes in states of matter. Light bulbs are excited with a Tesla coil to ionize gases, thus becoming an inexpensive plasma devices and a plasma tube shows magnetic interactions with plasma. The demonstration equipment used in this program is built with simple designs and common commercial equipment keeping in mind a teacher's tight budget. The SIC program ( ˜25 school presentations per year) has become very popular and has acquired an enthusiastic group of regular teacher clientele requesting repeat visits. In addition, three very popular and successful ``Build-It" days, sponsored by the General Atomics Fusion Education Outreach Program, enables teachers to build and keep in their classroom some of this equipment. The demonstration devices will be presented along with their ``build-it" details.

  3. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    bed, and a digital clock and a transponder helped to locate the camera. Equipment for the analysis of the nodules such as x-ray fluorescence and atomic absorption spectrophotometers were installed aboard MV Skandi Surveyor and MV Fernella and MV G A...

  4. Catalysis as a tool for energy conservation in the refinery industry; Catalisis como herramienta de ahorro de energia en la industria de la refinacion

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, S.; Moran-Pineda, M. [Instituto Mexicano del Petroleo, Mexico, D. F. (Mexico); Bazan, G.; Gonzalez, L.; Barrios, H. [Pemex-Refinacion, Mexico, D. F. (Mexico)

    1996-12-31

    The catalysis, defined by the alchemists since its appearance, as that something or Philosophical Stone, with a special power to transform matter by means of the energy, has always represented a challenge to mankind, even more now, when most of the goods needed for its survival are related to a chemical process and nowadays, when they can not be imagined without the presence of a catalyzer. In the reciprocity between the chemical change and the catalyzer, the energy utilized represents the critical point. Once stated the above, it becomes interesting the study of the impact and the consequence of the binomial catalysis-energy in relation to the fuel recovery processes and the emission control processes, originated by its combustion, where the main objective is in establishing an analysis criterion for energy conservation with different trends; the first one, on the impact of the application of optimum catalytic systems in the fuel recovery processes and the second one on the optimum catalytic processes for emissions control. [Espanol] La catalisis desde su aparicion definida por los alquimistas como ese algo o piedra filosofal, con una fuerza especial para la transformacion de la materia mediante la energia, siempre ha representado un reto para el hombre, mas aun en la actualidad donde la mayoria de los bienes necesarios para su supervivencia estan relacionados con un proceso quimico y que hoy en dia no se conciben estos sin la presencia de un catalizador. En la reciprocidad entre el cambio quimico y el catalizador, la energia utilizada representa el punto critico. Dado lo anterior, resulta interesante el estudio del impacto y trascendencia del binomio catalisis-energia en relacion con los procesos para la obtencion de los combustibles y de los procesos para el control de emisiones, producto de la combustion de los mismos, donde el objetivo primordial esta en establecer un criterio de analisis de ahorro de energia con diferentes directrices; la primera, el impacto

  5. Cuestiones actuales del régimen jurídico-administrativo de las Cajas de ahorros españolas

    Directory of Open Access Journals (Sweden)

    Ana Belén Casares Marcos

    2005-12-01

    Full Text Available Las reformas legislativas que han afectado en los últimos tiempos a la organización y el funcionamiento del sistema financiero español han tenido una especial repercusión en el ámbito de las cajas de ahorros. La tramitación parlamentaria de la Ley 44/2002, de 22 de noviembre, de Medidas de Reforma del Sistema Fianciero, reavivó el debate sobre su régimen jurídico y la necesidad de acotar la intervención pública en su seno. Ahonda en ello la Ley 26/2003 , de 17 de julio, de Transparencia, que extiende al ámbito de las cajas la preocupación por el corporate governance. Ambas normas responden a la necesidad de dar respuesta a algunos de los problemas más inmediatos a que se enfrentan estas entidades, si bien adolecen de un defecto fundamental por cuanto no abordan de forma exhaustiva la regulación de la institución. Se perpetúa así la trayectoria tradicional de "parcheo" del régimen jurídico aplicable a las mismas, evitando entrar en la cuestión esencial de la definición de su naturaleza jurídica y abocando a las cajas, en consecuencia, al díficil reto de acompasar su vocación social tradicional a las nuevas exigencias legales en pro de una mayor eficiencia, racionalidad y neutralidad de su acitividad económica.Recent legal changes pertaining to the organization and performance of the Spanish financial system have had significant repercussions on the savings banks sector. The law on financial market reform passed in 2002, Ley Financiera, raised once again the debate on their legal situation and the urge to cut down public influence on their management. The 2003 Transparency Law, Ley de Transparencia, follows this reform and extends corporate governance to Spanish savings banks. Both Laws seek to confront some of the most important issues raised by these credit institutions, but they also share the flaw of not regulating its legal framework and status completely. They continue, therefore, to add "patches" to the savings

  6. 40 CFR 63.1010 - Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief devices in...

    Science.gov (United States)

    2010-07-01

    ... standards. 63.1010 Section 63.1010 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (CONTINUED) National Emission Standards for Equipment Leaks-Control Level 1 § 63.1010 Pumps,...

  7. Use of ice storage equipment in the food industry

    Energy Technology Data Exchange (ETDEWEB)

    Vries, H. de

    1984-01-01

    The manufacture of foods in its widest sense demands a 'balanced supply of cooling'. Whenever 'cold requirement' occurs in different ways during production, the ice storage equipment in particular for 'cooling supplies'. The cooling performance (amount of cold from horizontal tubes and slabs or from horizontal pipes given off to the water flowing past) that can be expected from modern ice storage equipment, is made clear numerically. The way the storage vessel is constructed and its design have particular influence on the energy-saving quality (stirring mechanism with high performance at low pump capacity). Optimisation results for a plate evaporator design combined with a heat exchange system are presented. These include running cost savings of up to 18% in a yoghurt factory, a maltery and an ice cream factory. By means of this heat pump compound, environmental energy can be used in cold storage.

  8. [Water used for hemodialysis equipment: where is Pseudomonas aeruginosa?].

    Science.gov (United States)

    Ducki, Sébastien; Francini, Nicolas; Blech, Marie-Françoise

    2005-05-01

    The water used in dilution of the dialysis solutions constitutes an essential element of the efficiency and the safety of this therapeutics. Water must be specifically treated, and some technical rules must be respected, such as disinfection of the equipment for water treatment, to guarantee a satisfying level for whole the installation. This article reports the investigations, which were led to find the spring of Pseudomonas aeruginosa which contamined in a recurring way the water feeding dialysis equipment. The observation of samples'chronology and an analysis of the sanitary pad suggested a contamination during disinfection. Sample of residual water from the pump used for the injection of Dialox identified this reservoir as origin of the contamination. To stop this contamination by P. aeruginosa, a pump maintenance revision and purges of the system were used.

  9. Pressurized Vessel Slurry Pumping

    Energy Technology Data Exchange (ETDEWEB)

    Pound, C.R.

    2001-09-17

    This report summarizes testing of an alternate ''pressurized vessel slurry pumping'' apparatus. The principle is similar to rural domestic water systems and ''acid eggs'' used in chemical laboratories in that material is extruded by displacement with compressed air.

  10. Microfluidic "blinking" bubble pump

    NARCIS (Netherlands)

    Yin, Zhizhong; Prosperetti, Andrea

    2005-01-01

    The paper reports data obtained on a simple micropump, suitable for electrolytes, based on the periodic growth and collapse of a single vapor bubble in a microchannel. With a channel diameter of the order of 100 µm, pumping rates of several tens of µl/min and pressure differences of several kPa are

  11. Cold Climate Heat Pump

    Science.gov (United States)

    2013-08-01

    12. Data set 7 – energy consumption of heat pump and furnace ................................ 22 Figure 13. Experimentally adjusted TRNSYS model...minute SCF standard cubic feet SEER seasonal energy efficiency ratio SH superheated TMY Typical Meteorological Year TRNSYS Transient Systems...Simulation Program ( TRNSYS ), to generate an experimentally adjusted, simulation heating seasonal performance. 6.4.1 Simulation Results The TRNSYS model

  12. The Osmotic Pump

    Science.gov (United States)

    Levenspiel, Octave; de Nevers, Noel

    1974-01-01

    Describes the principle involved in an osmotic pump used to extract fresh water from the oceans and in an osmotic power plant used to generate electricity. Although shown to be thermodynamically feasible, the osmotic principle is not likely to be used commerically for these purposes in the near future. (JR)

  13. Optimization of compound gear pump

    Institute of Scientific and Technical Information of China (English)

    栾振辉

    2002-01-01

    This paper introduces the performances of compound gear pump. Based on the target of having the smallest mass per unit volume, the paper established a mathematical model of optimization, and obtained the results of optimization of the pump.

  14. RSES heat pump technician certification

    Energy Technology Data Exchange (ETDEWEB)

    Zeiner, J.

    1996-06-01

    In 1987 the National Heat Pump certification test was developed by the Refrigeration Service Engineers Society (RSES), and in 1994, the program was more specifically named Heat Pump Service Technician Certification. This report describes the benefits of certification.

  15. Orbital Liquid Oxygen Pump Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposed work will develop a pump, which is based on two novel and unique design features. The first feature is a lobed pumping mechanism which operates with...

  16. Performance of a solar augmented heat pump

    Science.gov (United States)

    Bedinger, A. F. G.; Tomlinsin, J. J.; Reid, R. L.; Chaffin, D. J.

    Performance results from a test house equipped with a parallel solar augmented heat pump system with off-peak storage and a utility interconnection back-up, are presented. The collector array consisted of 12 air heating flat plates with a 9 l/sec flow. Thermal storage was consigned to a 260 cu ft crushed limestone pebble bed, with an 8.8 kW heat pump used to draw heat from storage during off-peak hours and a 15 kW electrical resistance heater used to charge the pebble bed. Monitoring and data recording were carried out on all energy inputs and outputs of the systems, and a modified TRNSYS program was employed to model the system performance. The data indicate that although the system offered the possibility of reducing the utility capacity, the addition of the solar system did not significantly augment the performance of the heat-pump system, at least in terms of the cost of supplementary electricity.

  17. VIRTUAL FUEL-PUMP DESIGN

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Some concepts of virtual product are discussed. The key technologies of virtual fuel-pump development are in detail analysed, which include virtual fuel-pump product modeling, intelligent simulation, distributed design environment, and virtual assembly. The virtual fuel-pump development prototype system considers requirement analysis, concept design, injection preferment analysis, detailed design, and assembly analysis.

  18. Small Scroll Pump for Cryogenic Liquids Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a compact, reliable, light weight, electrically driven pump capable of pumping cryogenic liquids, based on scroll pump technology. This pump will...

  19. Improving pumping system efficiency at coal plants

    Energy Technology Data Exchange (ETDEWEB)

    Livoti, W.C.; McCandless, S.; Poltorak, R. [Baldor Electric Co. (United States)

    2009-03-15

    The industry must employ ultramodern technologies when building or upgrading power plant pumping systems thereby using fuels more efficiently. The article discusses the uses and efficiencies of positive displacement pumps, centrifugal pumps and multiple screw pumps. 1 ref., 4 figs.

  20. MODERNIZATION OF CUPOLA EQUIPMENT

    Directory of Open Access Journals (Sweden)

    S. L. Rovin

    2015-01-01

    Full Text Available This article presents an automated cupola complex, developed by scientific-production enterprise «Technolit» together with GSTU named after P. O. Sukhoi, launched in the spring of 2015 at the plant «Stroiex» in the city of Chelyabinsk (the Russian Federation. The old cupolas (open type have been replaced by the new cupolas of the closed type, equipped with automatic control and management system and multistage wet gas treatment system. Cupolas are equipped with systems of post-combustion gases and the batch charging, the separate systems of air blast, systems of sludge removal and recirculation of water, the slag granulation installations, mechanized cleaning of cupola furnace and automatic safety system. These activities allowed the company to increase production and improve the quality of cast iron, reduce the coke consumption by 20% and reducing emissions of pollutants into the atmosphere almost 30 times.

  1. Pumping characteristics of roots blower pumps for light element gases

    Energy Technology Data Exchange (ETDEWEB)

    Hiroki, Seiji; Abe, Tetsuya; Tanzawa, Sadamitsu; Nakamura, Jun-ichi; Ohbayashi, Tetsuro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2002-07-01

    The pumping speed and compression ratio of the two-stage roots blower pumping system were measured for light element gases (H{sub 2}, D{sub 2} and He) and for N{sub 2}, in order to assess validity of the ITER torus roughing system as an ITER R and D task (T234). The pumping system of an Edwards EH1200 (nominal pumping speed of 1200 m{sup 3}/s), two EH250s (ibid. 250 m{sup 3}/s) and a backing pump (ibid. 100 m{sup 3}/s) in series connection was tested under PNEUROP standards. The maximum pumping speeds of the two-stage system for D{sub 2} and N{sub 2} were 1200 and 1300 m{sup 3}/h, respectively at 60 Hz, which satisfied the nominal pumping speed. These experimental data support the design validity of the ITER torus roughing system. (author)

  2. Soviet equipment flies in

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    End of February 1977 a Soviet Ilyushin-76 heavy freight aircraft landed at Cointrin airport having on board fifty large wire proprtional chambers and associated apparatus, together weighing 10 tons, supplied by the Joint Institute for Nuclear Research, Dubna, USSR. The equipment was for the CERN- Dubna-Munich-Saclay experiment NA4 on deep inelastic muon scattering being set up in the North Area of SPS. See Weekly Bulletin 11/78.

  3. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  4. Equipment for gas conversion

    Energy Technology Data Exchange (ETDEWEB)

    Tabata, K.; Matsumoto, I.

    1983-01-28

    Equipment is proposed for vapor conversion of hydrocarbons (Uv), possibly in a mixture with air, in order to produce an inorganic gas, which chiefly consists of H2 and COx. It consists of a reaction pipe made of an inorganic refractory ceramic and equipped along the wall circumference with heaters. The reaction pipe is filled with a combined, multilayer catalyst (Kt) carrier, made of gamma-A1203 which in the transverse cross section has a multipore reticular or fibrous structure. Replacement of the traditional steel (St) materials for the walls of the reaction pipe with ceramic materials reduces the output of the hydrocarbon which contaminates the surface (Pv) of the catalyst; the use of a multilayer carrier for the catalyst made of gamma-A1203 with a porous reticular or fibrous structure reduces the pressure losses in the reactor and facilitates the replacement of the spent catalyst. The equipment is designed for vapor conversion of natural gas, C3H8, and vapors of kerosene, naphtha and so on.

  5. Performance influence in submersible pump with different diffuser inlet widths

    Directory of Open Access Journals (Sweden)

    Qingshun Wei

    2016-12-01

    Full Text Available The diffuser inlet width is a key geometric parameter that affects submersible pump performance. On the basis of diffuser characteristic curve analyses, diffusers with different inlet widths and the same impeller were equipped to construct a submersible pump model through the use of AutoCAD software. The performance curves of the submersible pump, with six diffuser inlet widths, were obtained using computational fluid dynamics method. Simultaneously, the simulation results were tested with the experimental method presented in this article. The results show that the optimum value of the inlet width (b3 = 50 mm is larger than the experience-based one. With an increase in the inlet width, the optimum operating point of a submersible pump offsets to a larger flow rate. When the guide blade inlet width is approximately 40–55 mm, the submersible pump efficiency is relatively high, approximately 75.9%–83.7% capacity, and the flow rate is approximately 105–135 m3/h. The numerical results of submersible pump performance are higher than those of the test results; however, their change trends have an acceptable agreement with each other. The practical significance is supplied by changing the inlet width of the diffuser to expand the scope of use.

  6. To Russia with pumps: Kudu conquers the former Soviet Union

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, A.

    2004-08-02

    PetroKazakhstan ordered two trailer trucks of progressing cavity pumps (PCPs) produced by Calgary-based Kudu Industries for use in their oil fields in Kazakhstan. The wells which had been producing 20 cubic meters per day with small pump jacks, are now capable of producing up to 400 cubic metres per day with the PCPs. In response, neighbouring oil companies have also placed orders for the new pumps. This paper described the various efforts on the part of Kudu Industries to gain support for their product in the former Soviet Union. The PCPs are based on a single helix rotor within an internal double helical stator. The pumps are more reliable than the aging Soviet-manufactured equipment. Kudu Industries responded to maintenance concerns by establishing a local shop in Kumkol near the oil fields, and by bringing Kazakh and Russian engineers and field operators to Canada for training. PCPs have made it economical to produce from wells that are 90 per cent water. The pumps have also proven their durability in the harshest environments in Western Canada. Future efforts will lie in developing an elastomer to handle high temperature pumping in areas such as steam assisted gravity drainage (SAGD). 2 figs.

  7. SHINE Vacuum Pump Test Verification

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, Gregg A; Peters, Brent

    2013-09-30

    Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to the movement of tritium through the SHINE Tritium Purification System (TPS). The purpose of the pump testing is two-fold: (1) obtain baseline vacuum pump characteristics for an alternate (i.e. ''Normetex replacement'') pump intended for use in tritium service; and (2) verify that low pressure hydrogen gas can be transported over distances up to 300 feet by the candidate pumps. Flow rates and nominal system pressures have been identified for the SHINE Mo-99 production process Tritium Purification System (TPS). To minimize the line sizes for the transfer of low pressure tritium from the Neutron Driver Accelerator System (NDAS) to the primary processing systems in the TPS, a ''booster'' pump has been located near the accelerator in the design. A series of pump tests were performed at various configurations using hydrogen gas (no tritium) to ensure that this concept is practical and maintains adequate flow rates and required pressures. This report summarizes the results of the tests that have been performed using various pump configurations. The current design of the Tritium Purification System requires the ''booster'' pump to discharge to or to be backed by another vacuum pump. Since Normetex pumps are no longer manufactured, a commercially available Edwards

  8. 14 CFR 23.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 23.991 Section 23.991... § 23.991 Fuel pumps. (a) Main pumps. For main pumps, the following apply: (1) For reciprocating engine installations having fuel pumps to supply fuel to the engine, at least one pump for each engine must be...

  9. Proposal for quantitative evaluation for medical equipment acquisition

    Directory of Open Access Journals (Sweden)

    Marcela Cristina Chaves Penco

    2004-01-01

    Full Text Available This paper proposes a method to evaluate the ideal number of medical equipment to be acquired by a Brazilian healthcare institution. The number of equipment needed (“n” in a hospital sector can be calculated with one expression, where the following parameters are taken into consideration: number of beds or users (“nb”; number of existing equipment (“m”; recommended rate of equipment per patient (“rr” that was obtained from Brazilian standard published by the Health Ministry; equipment importance to patient care (“v” that could be: life-support, improvement of the service or advisable; and the equipment condition (“c” that results from maintenance history data. These variables were obtained with data gathered from database and medical equipment preventive maintenance reports of the University Hospital of Londrina – Paraná – Brazil (HURNP/UEL. Two case studies were carried out. In the first case, the method was applied to work out the ideal number of infusion pumps needed for two different sectors (ICU and Nurseries in the hospital. The second study compared the ideal quantities of different equipment (pulse oximeter, oxicapnograph and multiparameter monitor that offered the same function (oximetry, in a surgical center. These results showed that this methodology is simple and easy to apply, although there must be an improvement of some aspects such as the local where the equipment is working and the possibility of different equipment performing the same function. Additionally, this paper showed the importance of implementing a prioritizing method among hospital sectors, because it will help to allocate resources where they are really necessary.

  10. Technical and economical assessment of the options for energy saving in the library of the Universidad Autonoma Metropolitana-Azcapotzalco; Evaluacion tecnico economica de opciones para el ahorro de energia en la biblioteca de la Universidad Autonoma Metropolitana-Azcapotzalco

    Energy Technology Data Exchange (ETDEWEB)

    Bratu, N.; Campero, E.; Dorantes, R.; Fuentes, V.; Figueroa, A.; Garcia, R.; Zekkour, A. [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico)

    1993-12-31

    This paper presents a diagnosis of the electrical energy consumption in the library of the Azcapotzalco Unit of the Universidad Autonoma Metropolitana, to determine the actions that can be implemented for energy conservation. This without disturbing the lighting and thermal comfort. The analysis showed that, by changing the reflecting surfaces of the lighting lamps, the number of units can be reduced, without lowering the illumination level below the recommended values. The saving was estimated for replacement of the fluorescent lamps for others of metallic halogenides in the areas where the ceiling is high; for the installation of switches to improve the selectivity in turning on and turning off the lamps, achieving this way a better usage of the natural light; for the reduction of the electric load of the air conditioning units which will be obtained in incorporating induced draft shafts; and for an improvement in the electric and ballast installation. For the actions that turned out to be redeemable in three years the assistance of the Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE) of the Comision Federal de Electricidad (CFE) has been available. It is expected that the execution of the modifications will be carried out in the November and December months of 1993, and the results will be evaluated in 1994. [Espanol] En este trabajo se presenta un diagnostico del consumo de energia electrica en la biblioteca de la Unidad Azcapotzalco de la Universidad Autonoma Metropolitana para determinar las acciones que se pueden llevar a cabo para ahorrar energia electrica. Esto sin deteriorar el confort luminico y termico. El analisis mostro que, cambiando las superficies reflectoras de las luminarias, se puede reducir el numero de lamparas, sin que el nivel de iluminacion quede debajo de los valores recomendados. Se estimaron ahorros: por la sustitucion de las lamparas fluorescentes por otras de halogenuros metalicos en las partes donde el

  11. Las Cajas de Ahorros en España durante el Régimen de Franco y la Transición Democrática : Su importancia en la economía regional

    Directory of Open Access Journals (Sweden)

    Luis Javier Coronas Vida

    2010-06-01

    Full Text Available En este artículo analizaremos las conexiones entre el desarrollo regional y la evolución de las cajas de ahorros, a partir del PIB regional per cápita y los depósitos en las cajas de ahorros, agrupados por regiones. El PIB real per cápita creció rápidamente en todas las regiones desde 1959 (el segundo franquismo. Aunque el crecimiento de las regiones pobres fue más fuerte que el de las ricas, en 1980 el PIB per cápita de las pobres no alcanzaba el 59% del correspondiente a las ricas (pero en 1945 era sólo el 43%. Los depósitos per cápita en las cajas de ahorros de las regiones pobres eran extremadamente reducidos en 1945 (sólo el 8% del dato correspondiente a las ricas; sin embargo en 1980 había alcanzado el 40%. El crecimiento de los depósitos en las regiones pobres fue acompañado por un crecimiento de la población débil (11% entre 1945 y 1980; por otra parte, el crecimiento demográfico en las regiones ricas alcanzó el 127%.In this paper we will analyse connections between regional development and the Savings Banks evolution in Spain, attending to regional GDP, per capita, and Savings Banks deposits accounts, gathered together by regions. Real GDP per capita, in all Spanish regions, increased quickly since 1959 (the 2nd Franco's era. Although, poor regions growth was stronger than that of the rich ones, in 1980, GDP per capita in poor regions didn't reach up to 59% of rich ones (even though in 1945 was only 43%.Savings Banks deposits per capita in poor regions were extremely short in 1945 (only 8% of the rich ones; nevertheless, in 1980 they reached 40%. Deposit increase in poor regions was also accompanied by a short population growth (11% between 1945 and 1980; on the other hand, demographic development in rich regions reached 127%.

  12. Pocket pumped image analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, I.V., E-mail: kotov@bnl.gov [Brookhaven National Laboratory, Upton, NY 11973 (United States); O' Connor, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Murray, N. [Centre for Electronic Imaging, Open University, Milton Keynes, MK7 6AA (United Kingdom)

    2015-07-01

    The pocket pumping technique is used to detect small electron trap sites. These traps, if present, degrade CCD charge transfer efficiency. To reveal traps in the active area, a CCD is illuminated with a flat field and, before image is read out, accumulated charges are moved back and forth number of times in parallel direction. As charges are moved over a trap, an electron is removed from the original pocket and re-emitted in the following pocket. As process repeats one pocket gets depleted and the neighboring pocket gets excess of charges. As a result a “dipole” signal appears on the otherwise flat background level. The amplitude of the dipole signal depends on the trap pumping efficiency. This paper is focused on trap identification technique and particularly on new methods developed for this purpose. The sensor with bad segments was deliberately chosen for algorithms development and to demonstrate sensitivity and power of new methods in uncovering sensor defects.

  13. Wavy tube heat pumping

    Energy Technology Data Exchange (ETDEWEB)

    Haldeman, C. W.

    1985-12-03

    A PVC conduit about 4'' in diameter and a little more than 40 feet long is adapted for being seated in a hole in the earth and surrounds a coaxial copper tube along its length that carries Freon between a heat pump and a distributor at the bottom. A number of wavy conducting tubes located between the central conducting tube and the wall of the conduit interconnect the distributor with a Freon distributor at the top arranged for connection to the heat pump. The wavy conducting tubing is made by passing straight soft copper tubing between a pair of like opposed meshing gears each having four convex points in space quadrature separated by four convex recesses with the radius of curvature of each point slightly less than that of each concave recess.

  14. Advanced heat pump cycle

    Energy Technology Data Exchange (ETDEWEB)

    Groll, E.A.; Radermacher, R.

    1993-07-01

    The desorption and absorption process of a vapor compression heat pump with a solution circuit (VCHSC) proceeds at gliding temperature intervals, which can be adjusted over a wide range. In case that the gliding temperature intervals in the desorber and the absorber overlap, a modification of the VCHSC employing a desorber/absorber heat exchange (DAHX) can be introduced, which results in an extreme reduction of the pressure ratio. Although the DAHX-cycle has features of a two-stage cycle, it still requires only one solution pump, one separator and one compressor. Such a cycle for the working pair ammonia/water is built in the Energy Laboratory of the Center for Environmental Energy Engineering at the University of Maryland. The experimental results obtained with the research plant are discussed and compared to those calculated with a simulation program. The possible temperature lift between heat source and heat sink depending on the achievable COP are presented.

  15. Inertial microfluidic pump

    Science.gov (United States)

    Kornilovitch, Pavel; Govyadinov, Alexander; Markel, David; Torniainen, Erik

    2015-11-01

    The inertial pump is powered by a microheater positioned near one end of a fluidic microchannel. As the microheater explosively boils the surrounding fluid, a vapor bubble expands and then collapses asymmetrically, resulting in net flow. Such devices become an effective means of transporting fluids at microscale. They have no moving parts and can be manufactured in large numbers using standard batch fabrication processes. In this presentation, physical principles behind pump operation are described, in particular the role of reservoirs in dissipating mechanical momentum and the expansion-collapse asymmetry. An effective one-dimensional dynamic model is formulated and solved. The model is compared with full three-dimensional CFD simulations and available experimental data. Potential applications of inertial micropumps are described.

  16. Technology assessment heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rudolph, R.; Purper, G. (Battelle-Institut e.V., Frankfurt am Main (Germany, F.R.))

    Technology assessment for an increased application of heat pumps is carried out in four areas: Effects in the economics area, i.e. effects on the economic goals which are defined in the Stability Law, on the goals of the power supply policy which result from the energy programme and its projections, and on the economic structure as a whole. The whole range of social problems concerning the use of heat pumps, i.e. the questions which social groups are affected, how they react, and what consequences are they expected to have on energy conservation as an object of social policy. Consequences in the governmental and administrative sectors, i.e. effects on legislation, administration and government budgets. Effects on the ecological systems; of prime interest in this context are the utilisation of environmental energy, changes in the heat balance, and emmission of pollutants.

  17. Hydrodynamics of Pumps

    OpenAIRE

    Brennen, Christopher Earls

    1994-01-01

    The subject of this monograph is the fluid dynamics of liquid turbomachines, particularly pumps. Rather than attempt a general treatise on turbomachines, we shall focus attention on those special problems and design issues associated with the flow of liquid through a rotating machine. There are two characteristics of a liquid that lead to these special problems, and cause a significantly different set of concerns than would occur in, say, a gas turbine. These are the potential for cavitation ...

  18. Positive displacement rotary pump

    Science.gov (United States)

    Moody, Paul E.

    1994-04-01

    An eccentric drive rotates inside a ring that is hinged to a plate and an elastomeric curtain is wrapped around the ring and across an articulated plate. The curtain moves along a cylindrical wall inside the pump cavity to move fluid from an inlet to an outlet end of the chamber. Two or more chambers can be coupled in series or in parallel with one another.

  19. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  20. Nonazeotropic Heat Pump

    Science.gov (United States)

    Ealker, David H.; Deming, Glenn

    1991-01-01

    Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

  1. Introduction to Pump Rotordynamics

    Science.gov (United States)

    2006-11-01

    RTO-EN-AVT-143 9 - 1 Introduction to Pump Rotordynamics Luis San Andrés Mast-Childs Tribology Professor Turbomachinery Laboratory Texas A... rotordynamics of turbomachinery, excessive vibration and instability. The acceptable performance of a turbomachine depends on the adequate design and operation...on rotordynamics . The basic equations for the modeling of linear rotor-bearing systems are given along with an example for the rotordynamics of a

  2. Electrocentrifugal pumping; Bombeo electrocentrifugo

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perez, Guillermo; Medellin Otero, Hector [Instituto Mexicano del Peroleo (Mexico)

    1996-07-01

    The exploitation of isolated oil deposits, in losing their own energy, enter a phase of secondary recovery. One of the technologies of new development in Mexico is the one of electrocentrifugal pumping , which consists of introducing the motor-pump as an integral part of the production pipe down to the well bottom and pumping directly up to central complexes, from where it is sent inland. In the present paper is intended to explain what this type of secondary recovery consists of. [Spanish] La explotacion de yacimientos aislados de petroleo, al perder su energia propia, entran en una fase de recuperacion secundaria. Una de las tecnologias de nuevo desarrollo en Mexico es la de bombeo electrocentrifugo, la cual consiste en introducir la motobomba como parte integral de la tuberia de produccion hasta el fondo del pozo y bombearlo directamente hasta los complejos centrales, de donde se envia a tierra. En el presente trabajo se pretende explicar en que consiste este tipo de recuperacion secundaria.

  3. Stirling Engine Heat Pump

    Science.gov (United States)

    Kagawa, Noboru

    Recent advances in the feasibility studies related to the Stirling engines and Stirling engine heat pumps which have been considered attractive due to their promising role in helping to solve the global environmental and energy problems,are reviewed. This article begins to describe the brief history of the Stirling engines and theoretical thermodynamic analysis of the Stirling cycle in order to understand several advantages on the Stirling engine. Furthermore,they could throw light on our question why the dream engines had not been promoted to practical applications during two hundred years. The present review shows that the Stirling engines with several unique advantages including 30 to 40% thermal efficiency and preferable exhaust characteristics,had been designed and constructed by recent tackling for the development of the advanced automobile and other applications using them. Based on the current state of art,it is being provided to push the Stirling engines combined with heat pumps based on the reversed Rankine cycle to the market. At present,however, many problems, especially for the durability, cost, and delicate engine parts must be enforced to solve. In addition,there are some possibilities which can increase the attractiveness of the Stirling engines and heat pumps. The review closes with suggestions for further research.

  4. A Magnetically Coupled Cryogenic Pump

    Science.gov (United States)

    Hatfield, Walter; Jumper, Kevin

    2011-01-01

    Historically, cryogenic pumps used for propellant loading at Kennedy Space Center (KSC) and other NASA Centers have a bellows mechanical seal and oil bath ball bearings, both of which can be problematic and require high maintenance. Because of the extremely low temperatures, the mechanical seals are made of special materials and design, have wearing surfaces, are subject to improper installation, and commonly are a potential leak path. The ball bearings are non-precision bearings [ABEC-1 (Annular Bearing Engineering Council)] and are lubricated using LOX compatible oil. This oil is compatible with the propellant to prevent explosions, but does not have good lubricating properties. Due to the poor lubricity, it has been a goal of the KSC cryogenics community for the last 15 years to develop a magnetically coupled pump, which would eliminate these two potential issues. A number of projects have been attempted, but none of the pumps was a success. An off-the-shelf magnetically coupled pump (typically used with corrosive fluids) was procured that has been used for hypergolic service at KSC. The KSC Cryogenics Test Lab (CTL) operated the pump in cryogenic LN2 as received to determine a baseline for modifications required. The pump bushing, bearings, and thrust rings failed, and the pump would not flow liquid (this is a typical failure mode that was experienced in the previous attempts). Using the knowledge gained over the years designing and building cryogenic pumps, the CTL determined alternative materials that would be suitable for use under the pump design conditions. The CTL procured alternative materials for the bearings (bronze, aluminum bronze, and glass filled PTFE) and machined new bearing bushings, sleeves, and thrust rings. The designed clearances among the bushings, sleeves, thrust rings, case, and case cover were altered once again using experience gained from previous cryogenic pump rebuilds and designs. The alternative material parts were assembled into

  5. Examination of pump failure data in the nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1996-12-01

    There are several elements that are critical to any program which is used to optimize the availability and reliability of process equipment. Perhaps the most important elements are routine monitoring and predictive maintenance elements. In order to optimize equipment monitoring and predictive maintenance, it is necessary to fundamentally and thoroughly understand the principal failure modes for the equipment and the effectiveness of alternative monitoring methods. While these observations are general in nature, they are certainly true for the {open_quotes}heart{close_quotes} of fluid systems - pumps. In recent years, particularly within the last decade, the capabilities and ease of use of previously existing pump diagnostic technologies, such as vibration monitoring and oil analysis, have improved dramatically. Newer technologies, such as thermal imaging, have been found effective at detecting certain undesirable or degraded conditions, such as misalignment and overheated bearings or packing. The ASME Code and NRC regulatory requirements have been, like essentially all similar code and regulatory bodies, conservative in their adoption or endorsement of newer technologies. The requirements prescribed by the Code and endorsed by the NRC have, in their essence, changed only minimally over more than a dozen years. As a follow-on to studies of check valve failure experience in the nuclear industry that have proven useful in identifying the effectiveness of alternative monitoring methods, a study of nuclear industry pump failure data has been conducted. The results of this study, conducted for the NRC by Oak Ridge National Laboratory, are presented. The historical effectiveness of both regulatory required and voluntarily implemented pump monitoring programs are shown. The distribution of pump failures by application, affected area, and level of significance are indicated. Apparent strengths and weaknesses of alternative monitoring methods are discussed.

  6. CFD Application in Implantable Rotary Blood Pump Design and Validation

    Institute of Scientific and Technical Information of China (English)

    YI Qian

    2004-01-01

    Implantable rotary blood pump (IRBP) has been promoted to the stage of clinical trial. This paper introduces a unique IRBP without a shaft. Instead of using thrombogenic pivots or power-drawing magnetic suspension, impeller is supported hydrodynamically when rotating, by lubrication flows in the thin spaces between itself and the pump body. To this end, the flow is very difficult to be measured using usual laboratory equipments. Therefore, computational fluid dynamics (CFD) has been applied as an important tool in the IRBP design and its validation procedure. Several CFD results such as pump performance improvement, unsteady hydraulic dynamic analysis, biocapability prediction, validation and verification (V&V), and flow visualization have been performed.

  7. CFD Application in Implantable Rotary Blood Pump Design and Validation

    Institute of Scientific and Technical Information of China (English)

    YIQian

    2004-01-01

    Implantable rotary blood pump (IRBP) has been promoted to the stage of clinical trial. This paper introduces a unique IRBP without a.shaft. Instead of using thrombogenic pivots or power-drawing magnetic suspension, impeller is supported hydrodynamically when rotating, by lubrication flows in the thin spaces between itself and the pump body. To this end, the flow is very difficult to be measured using usual laboratory equipments. Therefore, computational fluid dynamics (CFD) has been applied as an important tool in the IRBP design and its validation procedure. Several CFD results such as pump performance improvement, unsteady hydraulic dynamic analysis, biocapability prediction, validation and verification (V&V), and flow visualization have been performed.

  8. Report on technical feasibility of underground pumped hydroelectric storage

    Science.gov (United States)

    Doherty, T. J.

    1982-03-01

    The technical and economic aspects of constructing a very high head underground hydroelectric pumped storage were examined at a prefeasibility level. Excavation of existing caverns in the West Rutland Vermont marble quarry would be used to construct the underground space. A plant capacity of 1200 MW and 12 h of continuous capacity were chosen as plant operating conditions. The site geology, plant design, and electrical and mechanical equipment required were considered. It was concluded that the cost of the 1200 MW underground pumped storage hydro electric project at this site, even with the proposed savings from marketable material, amount to between $581 and $595 per kilowatt of installed capacity on a January 1982 pricing level. It was concluded that the West Rutland underground pumped storage facility is uneconomic at this time.

  9. How to Use Equipment Therapeutically.

    Science.gov (United States)

    Bowne, Douglas

    1986-01-01

    Shares therapeutic and economic practices surrounding equipment used in New York's Higher Horizons adventure program of therapy for troubled youth. Encourages educators, therapists, and administrators to explore relationship between equipment selection, program goals, and clients. (NEC)

  10. Opportunities for energy conservation detected in a diagnosis made for the smelting industry; Oportunidades de ahorro de energia detectadas en un diagnostico efectuado en la industria de la fundicion

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez Bautista, Rolando; Magana Castro, Rogelio [Fideicomiso de Apoyo al Programa de Ahorro de Energia del Sector Electrico (FIDE), Mexico, D. F. (Mexico)

    1993-12-31

    The smelting industry is one of the main industrial branches in the utilization of electric power at national level, for this reason an energy diagnosis was made in representative industries of this process in which excellent results were obtained regarding opportunity areas, with potentials ranging from 15% up to 40% of energy saving in relation to the energy consumption, with actions recoverable in less than 15 months. [Espanol] La industria de la fundicion es una de las principales ramas industriales en la utilizacion de la energia electrica a nivel nacional, por esta razon se realizo un diagnostico energetico en empresas representativas de este proceso y en las cuales se obtuvieron excelentes resultados en cuanto a areas de oportunidad, teniendo potenciales que van desde un 15% hasta un 40% de ahorro con relacion al consumo de energia, con medidas que se recuperan en menos de 15 meses.

  11. Método integral para mejorar el diseño de columnas de destilación, a partir de conceptos de ahorro de energía

    Directory of Open Access Journals (Sweden)

    Marco Antonio Ponce Guerrero

    2001-01-01

    Full Text Available Se presenta una metodología para analizar esquemas de destilación y proponer modificaciones que signifiquen ahorros de energía, mediante el uso de curvas de entalpía-temperatura que relacionan la operación simulada con el caso de una operación ideal reversible, tal como lo proponen Dhole y Linhoff. Se hace una aplicación a una columna de destilación atmosférica de crudo, que presenta un arreglo complejo con pumparounds y extracciones laterales. El resultado de adicionar un pumparound muestra una reducción en los consumos de energía, del orden de 400 millones de BTU/día, comprobando la utilidad de los métodos de análisis de procesos que utilizan la simulación.

  12. Research and Development on Heat Pumps for Space Conditioning Applications: Proceedings of the DOE/ORNL Heat Pump Conference

    Science.gov (United States)

    Jacobs, V. A.; Powell, R. H., Jr.

    1985-08-01

    This conference was planned to provide information on current activities in the US Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) Building Equipment Research (BER) Program. It was primarily for the benefit of HVAC equipment manufacturers and other interested parties, including utilities, independent research and development organizations, universities, other government groups, and research funding and management organizations. The technical presentations were grouped into two principal subject areas: electric systems and thermally activated systems. Electric-system topics included field performance studies, laboratory experiments on cycling performance, analytical estimates of the benefits of variable capacity and zone control, nonazeotropic refrigerant mixtures, ground-coupled systems, and an analysis of Stirling-cycle heat pumps. In the area of thermally activated heat pumps, presentations centered on the development of absorption systems, Stirling-engine-driven systems, and a linear, free-piston IC-engine compressor. Separate abstracts have been prepared for 27 presentations for inclusion in the Energy Data Base.

  13. Cavitation in liquid cryogens. 4: Combined correlations for venturi, hydrofoil, ogives, and pumps

    Science.gov (United States)

    Hord, J.

    1974-01-01

    The results of a series of experimental and analytical cavitation studies are presented. Cross-correlation is performed of the developed cavity data for a venturi, a hydrofoil and three scaled ogives. The new correlating parameter, MTWO, improves data correlation for these stationary bodies and for pumping equipment. Existing techniques for predicting the cavitating performance of pumping machinery were extended to include variations in flow coefficient, cavitation parameter, and equipment geometry. The new predictive formulations hold promise as a design tool and universal method for correlating pumping machinery performance. Application of these predictive formulas requires prescribed cavitation test data or an independent method of estimating the cavitation parameter for each pump. The latter would permit prediction of performance without testing; potential methods for evaluating the cavitation parameter prior to testing are suggested.

  14. NIH Standard. Animal Care Equipment.

    Science.gov (United States)

    National Institutes of Health (DHEW), Bethesda, MD. Office of Administrative Management.

    The National Institutes of Health standardized animal care equipment is presented in this catalog. Each piece of equipment is illustrated and described in terms of overall dimensions, construction, and general usage. A price list is included to estimate costs in budgeting, planning, and requisitioning animal care equipment. The standards and…

  15. Technical and economic working domains of industrial heat pumps: Part 1 - single stage vapour compression heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Jensen, Jonas Kjær; Markussen, Wiebke Brix;

    2015-01-01

    A large amount of operational and economic constraints limit the applicability of heat pumps operated with natural working fluids. The limitations are highly dependent on the integration of heat source and sink streams. An evaluation of feasible operating conditions was carried out considering...... the constraints of available refrigeration equipment and a requirement of a positive net present value of the investment. Six heat pump systems were considered, corresponding to an upper limit of the sink temperature of 120 °C. For each set of heat sink and source temperatures the best available technology...... was determined. The results showed that four different heat pump systems propose the best available technology at different parts of the complete domain. Ammonia systems presented the best available technology at low sink outlet temperature. At high temperature difference between sink in- and outlet...

  16. Abyssal soil investigation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Smits, F.P.; Maggioni, W.; Mainardi, U. [ISMES, Bergamo (Italy)

    1994-12-31

    The present paper deals with the development of a testing device for quick offshore geotechnical investigations. The equipment, at present, consists of a penetrometer, mounted on a sea bed platform, a handling frame and a control cabin; a further development includes a drill rig and a geotechnical laboratory. All this is designed so as to be an autonomous unit that can be handled by various types of non-specialized ships which have the necessary deck space. The sea bed platform can operate in 2,000 m of waterdepth and is provided with a hydraulic penetrometer, with a thrust capacity of 400 kN, able to carry out cone penetration type testing until a depth of more than 100 m, as well as shallow depth continuous sampling. The penetrometer can be equipped with a series of probes (piezocone, pressiocone, total radial pressure transducer, seismic cone) allowing the execution of the wide range of direct geotechnical measurements normally performed during on-land penetration tests.

  17. BENEFITS OF VIBRATION ANALYSIS FOR DEVELOPMENT OF EQUIPMENT IN HLW TANKS - 12341

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Herbert, J.

    2012-01-10

    Vibration analyses of equipment intended for use in the Savannah River Site (SRS) radioactive liquid waste storage tanks are performed during pre-deployment testing and has been demonstrated to be effective in reducing the life-cycle costs of the equipment. Benefits of using vibration analysis to identify rotating machinery problems prior to deployment in radioactive service will be presented in this paper. Problems encountered at SRS and actions to correct or lessen the severity of the problem are discussed. In short, multi-million dollar cost saving have been realized at SRS as a direct result of vibration analysis on existing equipment. Vibration analysis of equipment prior to installation can potentially reduce inservice failures, and increases reliability. High-level radioactive waste is currently stored in underground carbon steel waste tanks at the United States Department of Energy (DOE) Savannah River Site and at the Hanford Site, WA. Various types of rotating machinery (pumps and separations equipment) are used to manage and retrieve the tank contents. Installation, maintenance, and repair of these pumps and other equipment are expensive. In fact, costs to remove and replace a single pump can be as high as a half million dollars due to requirements for radioactive containment. Problems that lead to in-service maintenance and/or equipment replacement can quickly exceed the initial investment, increase radiological exposure, generate additional waste, and risk contamination of personnel and the work environment. Several different types of equipment are considered in this paper, but pumps provide an initial example for the use of vibration analysis. Long-shaft (45 foot long) and short-shaft (5-10 feet long) equipment arrangements are used for 25-350 horsepower slurry mixing and transfer pumps in the SRS HLW tanks. Each pump has a unique design, operating characteristics and associated costs, sometimes exceeding a million dollars. Vibration data are routinely

  18. Disponer las prácticas: consumo, crédito y ahorro en un asentamiento del gran Buenos Aires = Arranging practice: consumption, credit and saving on a settlement in the metropolitan area of Buenos Aires

    Directory of Open Access Journals (Sweden)

    Figueiro, Pablo

    2010-01-01

    Full Text Available El presente artículo se propone indagar sobre las especificidades que adopta el uso del dinero en sectores subalternos a partir de un trabajo de campo realizado en un asentamiento de la localidad de José León Suárez, provincia de Buenos Aires. Se sostiene que en el cruce entre, por un lado, las modalidades que asume la percepción del ingreso en dicha población y, por el otro, los mecanismos formales e informales que regulan la relación con el dinero, se generan prácticas específicas de consumo, crédito y ahorro que tienden a profundizar las desigualdades existentes en dichos sectores. En este sentido, el trabajo plantea que las prácticas de consumo son estructuradas en torno a las condiciones de percepción del ingreso, es decir, a partir del trabajo del que se disponga – formal o informal –, la regularidad del pago – fijo o no y, en el primer caso, con que frecuencia temporal se percibe – y la forma del mismo – si se halla bancarizado o no –. Vinculado a esto, se desprenden distintas posibilidades de acceso a créditos – en bancos, en casas de venta de bienes para el hogar, de “confianza” entre parientes y vecinos y/o en comercios del lugar – que suponen otras tantas formas de relación con el tiempo y de la vivencia y calculabilidad del mismo. Estas cuestiones, entrecruzadas por reglamentaciones, exclusiones y controles que operan modelando las formas que adopta el gasto, encuadran formas diferenciales del manejo del dinero y del ahorro

  19. Propuesta de un sistema de aprovechamiento de agua lluvia como alternativa para el ahorro de agua potable, en la institución educativa María Auxiliadora de Caldas, Antioquia

    Directory of Open Access Journals (Sweden)

    Palacio Castañeda Natalia

    2011-11-01

    Full Text Available El aprovechamiento del agua lluvia es una práctica interesante, tanto ambiental como económicamente, si se tiene en cuenta la gran demanda del recurso sobre las cuencas hidrográficas, el alto grado de contaminación de las fuentes superficiales y los elevados costos por el consumo de agua potable en una institución educativa. Este proyecto presenta la ingeniería conceptual de una propuesta de diseño de un si stema de aprovechamiento de agua lluvia como alternativa para el ahorro de agua potable en usos tales como la descarga de sanitarios, el lavado de zonas comunes, entre otros. Se presenta, adicionalmente, un análisis aproximado de la viabilidad técnica y económica de dicho aprovechamiento en una institución educativa del municipio de Caldas, Antioquia. Se desarrollan en este documento tres aspectos principales: el cálculo de los volúmenes disponibles de agua lluvia en la zona, la evaluación del volumen de agua potable ahorrado con el aprovechamiento del agua lluvia, la estimación del presupuesto para la construcción del sistema y la proyección del ahorro generado al utilizarlo. Los resultados sugieren que el aprovechamiento de agua lluvia es una opción técnicamente viable, pero financieramente no, pues la inversión inicial es alta, por lo que es importante buscar financiación externa para desarrollar este tipo de proyectos que representan una solución interesante para contribuir al desarrollo sostenible de la institución educativa.

  20. Direct pumping of four levels lasing materials

    Science.gov (United States)

    Goldring, Sharone; Lavi, Raphael; Tal, Alon; Jackel, Steven M.; Lebiush, Eyal; Tzuk, Yitshak; Azoulay, Ehud

    2003-06-01

    Heat generation and laser performance were studied in Nd:YAG oscillators pumped with a Ti:Sapphire laser in two regimes: band pumping at 802nm and direct pumping at 885nm. Slope efficiencies of 52% and 57%, when pumped at 802nm and 885nm, were obtained, respectively. Heat per unit laser output was found to be 27% lower when pumped at 885nm (direct pumping regime) as compared to traditional band pumping around 808nm.

  1. Remanufacturing strategy for chemical equipment

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xian-cheng; XU Bin-shi; WANG Hai-dou; JIANG Yi; WU Yi-xiong; GONG Jian-ming; TU Shan-dong

    2005-01-01

    Failure, especially induced by cracks, usually occurred in the service process of chemical equipment, which could cause the medium leakage, fire hazard and explosion and induced the personnel casualty and economic losses. To assure the long-term and safety service, it is necessary to apply the remanufacturing technology on the chemical equipment containing cracks. The recent research advances on the remanufacturing, the failure modes and the life extension technology for chemical equipment were reviewed. The engineering strategy of the remanufacturing for the chemical equipment was proposed, which could provide a reasonable and reliable technical route for the remanufacturing operation of chemical equipment. In the strategy, the redesign was also been considered.

  2. Proper Sizing of Circulation Pumps

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Nørgaard, Jørgen

    2007-01-01

    , but the results can be applied to Europe in general. Despite the small sample of houses involved in the test, 15 houses, some rather safe conclusions can be drawn from the results, which showed that newly developed pumps with power consumption around 5-8 W, can perform the task of circulating the water...... sufficiently to keep the houses satisfactorily warm during the heating season of the test. The old replaced pumps used 5-10 times more power. In Europe alone, a gradual replacement of the present vastly oversized pumps with such small but sufficient pumps can save the construction of 17 large power plants...... as well as their pollution during operation. Policy measures are proposed of how to ensure that in the future only such energy saving pumps are installed. Furthermore, on the basis of the historic experiences with circulation pumps some con¬clusions are drawn on how to investigate, develop and market new...

  3. 印染厂节能减排实用工艺装备技术(五)——染整设备风机、泵类调速的节电%Processes and equipments for energy saving and emission reduction in dyeing plants(V)——Speed governing and energy saving of fan and pump in dyeing and finishing machines

    Institute of Scientific and Technical Information of China (English)

    陈立秋

    2011-01-01

    Air volume of fan and pump flow in dyeing and finishing machines fluctuate within wide ranges, their shaft powers are in proportion to the cube of the rotating speed, they can be controlled close to ideal control curve by AC variable frequency speed regulation. Advantages of AC variable frequency speed regulation are introduced. Results of technological upgrading of typical machines in dyeing and finishing companies are enumerated.%染整设备的风机风量和泵类流量在运行中变化大,其轴功率与转速的立方成正比,采用交流变频调速控制,可接近理想控制曲线.文中论述了交流变频调速的优点,列举了染整企业典型设备的技改效果.

  4. Research on synchronous gear pump

    Institute of Scientific and Technical Information of China (English)

    LUAN Zhen-hui

    2010-01-01

    Based on a comprehensive analysis of the structure and existing problems of the gear pump, provided a structure principle of a synchronous gear pump. The discussions focused on the working principle, construction features and finite element analysis of the hydraulic gear. The research indicates that the new pump has such advantages as lower noise, better distributed flow and a high work pressure, and it can be widely used in hydraulic systems.

  5. Centrifugal pumps and allied machinery

    CERN Document Server

    Anderson, HH

    1994-01-01

    This book will be of vital interest to all engineers and designers concerned with centrifugal pumps and turbines. Including statistical information derived from 20000 pumps and 700 turbines with capacities of 5gpm to 5000000gpm, this book offers the widest range and scope of information currently available. Statistical analyses suggest practical methods of increasing pump performance and provide valuable data for new design aspects.

  6. Study on operation of a research reactor during one PCS pump failure accident

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kyoung Woo; Yoon, Hyu Ngi; Kim, Seong Hoon; Chi, Dae Young; Yoon, Juh Yeon [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The Primary cooling system (PCS) of a research reactor is designed to provide adequate cooling to the reactor core with a reasonable margin during all operation modes. The PCS consists of pumps, heat exchangers, and all necessary interconnecting pipes, valves, and instruments. The number of pumps is determined from a safety and economic point of view. As the number of pump trains increase, the cost increases according to the increase in safety class equipment. However, it is impossible to install one pump for a PCS because a zero flow can instantaneously occur during a pump failure such as a pump seizure. Thus, a PCS frequently consists of two parallel 50% capacity pumps and heat exchangers. In addition, check valves are generally installed to prevent a reversal flow when multiple pumps are designed to operate. However, if a swing type check valve is used, it should be estimated whether the slam due to instantaneous closing of the valve affects the system vibration. To reduce the vibration by a slam phenomenon, additional equipment such as a damper will be installed in the valve. The purpose of the check valve in PCS is to prevent the flow path when a reverse flow occurs. The installation of additional equipment will make it difficult to perform this function. In this study, it is estimated whether the PCS can operate without check valves. First, a flow analysis using Flowmaster was compared and verified by the calculation employing a empirical correlation. Second, the simulation for a one pump failure accident was performed and analyzed.

  7. DEVELOPMENT OF OPERATING DRIVE SYSTEMS IN ENGINEERING EQUIPMENT

    Directory of Open Access Journals (Sweden)

    A. A. Kotlobai

    2015-01-01

    Full Text Available Engineering machines being in operational service with military units of  engineer troops are fit to their purpose and their application is relevant in modern conditions. Maintenance of operating conditions in engineering equipment which was produced earlier by the USSR enterprises is considered as a rather complicated task due to lack of spare parts because their production has been discontinued.One of the approaches used for maintenance of engineering equipment combat capabilities is modernization of operating drive systems that presupposes replacement of mechanical systems in working element drives by hydrostatic drives which are realized while using modern element base. Usage of hydraulic units in drive systems being in mass production for replacement of mechanical systems manufactured earlier in small batches makes it possible to reduce labour inputs for maintenance and repair of machines. The paper presents some possibilities for development of operating drive systems in engineering equipment. The proposed approach is given through an example of  engineering obstacle-clearing vehicle (IMR-2M and excavation machines (MDK-3 and MDK-2M.Application of a hydraulic drive in working elements of the excavation machines permits to withdraw from cardan  shafts, a gear box, a rotary gear and an overload clutch. A hydraulic motor of the cutter and thrower drive is mounted  on a working element gearbox. While executing modernization of hydraulic systems in excavation machines a pump unit has been proposed for the cutter and thrower drive which consists of a controlled pump and a system for automatic maintenance of the pump operational parameters. While developing the operating drive systems in engineering equipment in accordance with the proposed requirements it is possible to simplify drive systems of working elements and  ensure reliable machinery operation in the units of engineer troops. 

  8. How to improve centrifugal pumps reliability; Como aumentar a confiabilidade de bombas centrifugas

    Energy Technology Data Exchange (ETDEWEB)

    Pedreira, Java Atayde [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2004-07-01

    The competitive market where the petroleum and petrochemicals industries are inserted has been taking to significant reductions of its profit margins, leading them to pursue costs reduction and change its way of working, in order to turn them more competitive. The reliability of the plant has a direct impact in the operational costs and it is extremely dependent of the performance of the rotating equipment, predominantly centrifugal pumps. Investments for optimize the reliability of the plants and to reduce the maintenance needs have become imperative for the reduction of the operational and maintenance costs. And why do the pumps fail so much? This is a question that all the pump users make themselves, dealing with an apparently so simple equipment. The pump maintenance costs is about 30 % of rotating equipment total cost.Vibration, mechanical seal failures and efficiency loss are the greatest responsible causes of such high maintenance costs. Many factors should be considered in the analysis of the causes of such low performance. Errors of project, application, installation, maintenance and operation of the pumps are the greatest responsible factors for its low performance. This article makes a detailed analysis of the impact of these factors in the performance of these equipment, discussing the best practices that should be adopted and maintained, in order to assure an optimum reliability. (author)

  9. Hyperbaric intensive care technology and equipment.

    Science.gov (United States)

    Millar, Ian L

    2015-03-01

    In an emergency, life support can be provided during recompression or hyperbaric oxygen therapy using very basic equipment, provided the equipment is hyperbaric-compatible and the clinicians have appropriate experience. For hyperbaric critical care to be provided safely on a routine basis, however, a great deal of preparation and specific equipment is needed, and relatively few facilities have optimal capabilities at present. The type, size and location of the chamber are very influential factors. Although monoplace chamber critical care is possible, it involves special adaptations and inherent limitations that make it inappropriate for all but specifically experienced teams. A large, purpose-designed chamber co-located with an intensive care unit is ideal. Keeping the critically ill patient on their normal bed significantly improves quality of care where this is possible. The latest hyperbaric ventilators have resolved many of the issues normally associated with hyperbaric ventilation, but at significant cost. Multi-parameter monitoring is relatively simple with advanced portable monitors, or preferably installed units that are of the same type as used elsewhere in the hospital. Whilst end-tidal CO₂ readings are changed by pressure and require interpretation, most other parameters display normally. All normal infusions can be continued, with several examples of syringe drivers and infusion pumps shown to function essentially normally at pressure. Techniques exist for continuous suction drainage and most other aspects of standard critical care. At present, the most complex life support technologies such as haemofiltration, cardiac assist devices and extra-corporeal membrane oxygenation remain incompatible with the hyperbaric environment.

  10. Dynamic damper pressure fluctuation in the pumping systems

    Directory of Open Access Journals (Sweden)

    O.V. Korolyov

    2016-05-01

    Full Text Available Inertial part of any devices and equipment (e.g., pumps, hung or mounted on the resilient frame and being under the influence of the disturbing force that works at a constant frequency, may be subject to fluctuations, especially near of the resonance area. For elimination these fluctuations, you can resort to the use of a dynamic damper. Aim: The aim of the work is an analytical study of various dynamic dampers to reduce pressure fluctuation problems in pumping systems. Materials and Methods: A comparative analysis of efficiency of functioning was carried out for two types of dynamic dampers - hydraulic and mechanical. Results: The technique for calculating of dynamic damper of fluid pressure fluctuations in the hydraulic and mechanical pumps is presented. Algorithms of calculations are reported to engineering applications and implemented in the production process. The calculations show that the use of dynamic mechanical dampers is expedient at high frequency pumps, and, with increasing frequency of the pump by 6 times, winning in the dimensions of the damper in 3.5 times.

  11. Theoretical Prediction of the Pumping Performance of Dry Pumps (Taking the Scroll Pump and the Screw Pump by Way of Example)

    Science.gov (United States)

    Sawada, Tadashi; Ohbayashi, Tetsuro

    Since almost all commercially provided dry pumps are of the positive displacement type, the leak flow through clearance between displacement chambers in the pump is a dominant factor which determines pumping performance. Prediction methods for the pumping performance of dry pumps are explained by comparing it to the scroll pump and the screw pump. The scroll pump has long clearances, but the screw pump has relatively short ones, and the volume of the chambers reduces from the inlet toward the outlet in the scroll pump, but that in the screw pump is kept constant throughout the pumping process. Such a structural difference produces a small difference in the way of treating leak flow. These two methods can be applied to the other dry pumps requiring only minor modification.

  12. Experiences with large heat pumps for space heating. Erfaringer med store varmepumper til rumopvarmning

    Energy Technology Data Exchange (ETDEWEB)

    Willumsen, O.

    1984-01-01

    In Denmark, only a moderate number of large heat pumps has been installed. Large heat pumps are in this context defined as heat pumps with a heat output exceeding 50 kW. Heat sources for these heat pumps are - to some extent - the same as for smaller heat pumps, i.e. outdoor air, exhaust air, soil and ground water. The use of sewage water, water from lakes or seawater also is rather commen. Besides, more special heat sources based on industrial waste heat are being utilized. The report primarily deals with heat pumps using the most common heat sources. This means that industrial heat pumps are not included in this report. In a few cases it has been considered appropriate to include heat pumps with a heat output smaller than 50 kW, when the experiences from these installations are considered relevant for larger plants. Some of the main findings of the survey are: - When designing heat pump installations, greater attention should be paid towards a more precise evaluation of the annual energy demand of the heat load. - Consulting firms generally have inadequate knowledge of the practical attainable seasonal COP's. - The energy surveillance equipment is insufficient in many installations - or is missing completely. - Salt-based antifreeze solutions should normally be avoided. - Utilizing ground water as a heat source can be problematic due to fouling problems or corrosion damages.

  13. Lasers with nuclear pumping

    CERN Document Server

    Melnikov, S P; Sizov, A N; Miley, George H

    2015-01-01

    This book covers the history of lasers with nuclear pumping (Nuclear Pumped Lasers, NPLs). This book showcases the most important results and stages of NPL development in The Russian Federal Nuclear Center (VNIIEF) as well as other Russian and international laboratories, including laboratories in the United States. The basic science and technology behind NPLs along with potential applications are covered throughout the book. As such, this book: ·         Contains a historical overview of the extensive information developed over the past 40 years of work on NPLs ·         Covers the most important results and stages of NPL development, not just in the Russian Federal Nuclear Center, VNIIEF, but also in other laboratories in Russia, the United States , and some other scattered international laboratories ·         Systematizes the fragmented information accumulated over these years of very active research and development As the first comprehensive discussion of NPLs, students, research...

  14. The terrestrial silica pump.

    Directory of Open Access Journals (Sweden)

    Joanna C Carey

    Full Text Available Silicon (Si cycling controls atmospheric CO(2 concentrations and thus, the global climate, through three well-recognized means: chemical weathering of mineral silicates, occlusion of carbon (C to soil phytoliths, and the oceanic biological Si pump. In the latter, oceanic diatoms directly sequester 25.8 Gton C yr(-1, accounting for 43% of the total oceanic net primary production (NPP. However, another important link between C and Si cycling remains largely ignored, specifically the role of Si in terrestrial NPP. Here we show that 55% of terrestrial NPP (33 Gton C yr(-1 is due to active Si-accumulating vegetation, on par with the amount of C sequestered annually via marine diatoms. Our results suggest that similar to oceanic diatoms, the biological Si cycle of land plants also controls atmospheric CO(2 levels. In addition, we provide the first estimates of Si fixed in terrestrial vegetation by major global biome type, highlighting the ecosystems of most dynamic Si fixation. Projected global land use change will convert forests to agricultural lands, increasing the fixation of Si by land plants, and the magnitude of the terrestrial Si pump.

  15. SAFETY ANALYSIS FOR TANK 241-AZ-101 MIXER PUMP PROCESS TEST

    Energy Technology Data Exchange (ETDEWEB)

    HAMMOND DM; HARRIS JP; MOUETTE P

    1997-06-09

    This document contains the completed safety analysis which establishes the safety envelope for performing the mixer pump process test in Tank 241-AZ-101. This process test is described in TF-210-OTP-001. All equipment necessary for the mixer pump test has been installed by Project W-151. The purpose of this document is to describe and analyze the mixer pump test for Aging Waste Facility (AWF) Tank 241-AZ-101 and to address the 'yes/maybe' responses marked for evaluation questions identified in Unreviewed Safety Question Evaluation (USQE) TF-94-0266. The scope of this document is limited to the performance of the mixer pump test for Tank 241-AZ-101. Unreviewed Safety Question Determination (USQD) TF-96-0018 verified that the installation of two mixer pumps into Tank 241-AZ-101 was within the current Tank Waste Remediation System (TWRS) Authorization Basis. USQDs TF-96-0461, TF-96-0448, and TF-96-0805 verified that the installation of the in-tank video camera, thermocouples, and Ultrasonic Interface Level Analyzer (URSILLA), respectively, were within the current TWRS Authorization Basis. USQD TF-96-1041 verified that the checkout testing of the installed equipment was within the current TWRS Authorization Basis. Installation of the pumps and equipment has been completed. An evaluation of safety considerations associated with operation of the mixer pumps for the mixer pump test is provided in this document. This document augments the existing AWF authorization basis as defined in the Interim Safety Basis (Stahl 1997), and as such, will use the existing Interim Operational Safety Requirements (IOSRs) of Heubach 1996 to adequately control the mixer pump test. The hazard and accident analysis is limited to the scope and impact of the mixer pump test, and therefore does not address hazards already addressed by the current AWF authorization basis. This document does not evaluate removal of the mixer pumps. Safety considerations for removal of the pumps will be

  16. Experiment research on grain drying process in the heat pump assisted fluidized beds

    Institute of Scientific and Technical Information of China (English)

    Jing Yang; Li Wang; Fi Xiang; Lige Tong; Hua Su

    2004-01-01

    A heat pump assisted fluidized bed grain drying experimental system was developed. Based on this system, a serial of experiments was performed under four kinds of air cycle conditions. According to the experimental analysis, an appropriate drying medium-air cycle for the heat pump assisted fluidized bed drying equipment was decided, which is different from the commonly used heat pump assisted drying system. The experimental results concerning the drying operation performance of the new system show that the averaged coefficient of performance (COP) can reach more than 2.5. The economical evaluation was performed and the powefficiency and great application potentiality in future market.

  17. Reliance on Pumped Mother’s Milk Has an Environmental Impact

    Directory of Open Access Journals (Sweden)

    Genevieve Becker

    2016-09-01

    Full Text Available Breastfeeding is an environmentally friendly process; however when feeding relies on pumped mother’s milk, the environmental picture changes. Waste plastics and heavy metals raise concerns regarding resource efficiency, waste treatment, and detrimental effects on health. Reliance on pumped milk rather than breastfeeding may also effect obesity and family size, which in turn have further environmental impacts. Information on pump equipment rarely includes environmental information and may focus on marketing the product for maximum profit. In order for parents, health workers, and health policy makers to make informed decisions about the reliance on pumped mother’s milk, they need information on the broad and far reaching environmental aspects. There was no published research found that examined the environmental impact of using pumped mother’s milk. A project is ongoing to examine this issue.

  18. Reliance on Pumped Mother’s Milk Has an Environmental Impact

    Science.gov (United States)

    Becker, Genevieve; Ryan-Fogarty, Yvonne

    2016-01-01

    Breastfeeding is an environmentally friendly process; however when feeding relies on pumped mother’s milk, the environmental picture changes. Waste plastics and heavy metals raise concerns regarding resource efficiency, waste treatment, and detrimental effects on health. Reliance on pumped milk rather than breastfeeding may also effect obesity and family size, which in turn have further environmental impacts. Information on pump equipment rarely includes environmental information and may focus on marketing the product for maximum profit. In order for parents, health workers, and health policy makers to make informed decisions about the reliance on pumped mother’s milk, they need information on the broad and far reaching environmental aspects. There was no published research found that examined the environmental impact of using pumped mother’s milk. A project is ongoing to examine this issue. PMID:27626456

  19. Diode-pumped laser with improved pumping system

    Science.gov (United States)

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  20. Design of Pumps for Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Klit, Peder; Olsen, Stefan; Bech, Thomas Nørgaard

    1999-01-01

    This paper considers the development of two pumps for water hydraulic applications. The pumps are based on two different working principles: The Vane-type pump and the Gear-type pump. Emphasis is put on the considerations that should be made to account for water as the hydraulic fluid.......KEYWORDS: water, pump, design, vane, gear....

  1. About Variable Speed Heating and Cooling Pumps

    OpenAIRE

    Cătălin Popovici; Jan Ignat

    2009-01-01

    The present work has the purpose of underlying the advantages of variable speed heating and cooling pumps use for the perspective of general and particular pumping costs and efficiency. The study approaches comparisons between constant flow pumps and variable flow pumps in different given situations and comparatively analyses the pumping costs.

  2. 46 CFR 119.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Bilge pumps. 119.520 Section 119.520 Shipping COAST... Ballast Systems § 119.520 Bilge pumps. (a) Each vessel must be provided with bilge pumps in accordance... have a portable hand bilge pump that must be: (1) Capable of pumping water, but not...

  3. 46 CFR 154.1135 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pumps. 154.1135 Section 154.1135 Shipping COAST GUARD... Pumps. (a) Water to the water spray system must be supplied by: (1) A pump that is only for the use of the system; (2) A fire pump; or (3) A pump specially approved by the Commandant (CG-522)....

  4. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  5. Heat-Powered Pump for Liquid Metals

    Science.gov (United States)

    Campana, R. J.

    1986-01-01

    Proposed thermoelectromagnetic pump for liquid metal powered by waste heat; needs no battery, generator, or other external energy source. Pump turns part of heat in liquid metal into pumping energy. In combination with primary pump or on its own, thermoelectric pump circulates coolant between reactor and radiator. As long as there is decay heat to be removed, unit performs function.

  6. Preliminary design study of underground pumped hydro and compressed-air energy storage in hard rock. Volume 8: Design approaches: UPH

    Science.gov (United States)

    1981-06-01

    The development of the design approaches used to determine the plant and overall layout for a underground pumped hydroelectric (UPH) storage facility having a maximum generating capacity of 2000 MW and a storage capacity of 20,000 MWh is discussed. Key factors were the selection of the high head pump-turbine equipment and the geotechnical considerations relevant to the underground cavern designs. The comparison of pump-turbine alternatives is described leading to the selection for detailed study of both a single-step configurations, using multistage reversible pump-turbines, and a two-step configuration, with single-stage reversible pump-turbines.

  7. Pumps in wearable ultrafiltration devices: pumps in wuf devices.

    Science.gov (United States)

    Armignacco, Paolo; Garzotto, Francesco; Bellini, Corrado; Neri, Mauro; Lorenzin, Anna; Sartori, Marco; Ronco, Claudio

    2015-01-01

    The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features.

  8. THE EFFICIENCY OF GAS-PUMPING UNITS

    Directory of Open Access Journals (Sweden)

    E. I. Kupreev

    2016-01-01

    Full Text Available . The reliability of the gas transmission network of the JSC “Gazprom Transgaz Belarus” depends on the efficiency of gas compressor units. Pipeline transport takes the first place among all the other ways to deliver gas because it ensures a uniform and uninterrupted supply of gas at minimum costs. The main objects of main gas pipelines include process areas, including several compressor stations and sections of the pipeline between them. Currently, a significant part of the main equipment of the gas industry is approaching its deadline of operation, which causes decrease in energy efficiency and reliability of the transmission system. At compressor plants of the JSC “Gazprom Transgaz Belarus” there are more than 4000 gas compressor units in operation including about 80% ones with gas turbine drives. It is clear that the drives of these units take a significant proportion of the pumped gas. For many years the company invests and actively participates in the creation of modern gas-pumping units practicing the wide use of conversion potential of the CIS countries. In recent years, a comprehensive approach to the assessment of the reliability and efficiency of objects of gas pipelines on the basis of mathematical modeling is actively applied. Together with the development of computer supervisory and control this opens up opportunities to improve energy efficiency in pipeline transport of gas on the basis of mathematical models and processes. The real effect obtaining is based on the actual performance of the equipment that needs to be monitored over time and to clarify.

  9. The measured field performances of eight different mechanical and air-lift water-pumping wind-turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kentfield, J.A.C. [Univ. of Calgary, Alberta (Canada)

    1996-12-31

    Results are presented of the specific performances of eight, different, water-pumping wind-turbines subjected to impartial tests at the Alberta Renewable Energy Test Site (ARETS), Alberta, Canada. The results presented which were derived from the test data, obtained independently of the equipment manufacturers, are expressed per unit of rotor projected area to eliminate the influence of machine size. Hub-height wind speeds and water flow rates for a common lift of 5.5 m (18 ft) constitute the essential test data. A general finding was that, to a first approximation, there were no major differences in specific performance between four units equipped with conventional reciprocating pumps two of which employed reduction gearing and two of which did not. It was found that a unit equipped with a Moyno pump performed well but three air-lift machines had, as was expected, poorer specific performances than the more conventional equipment. 10 refs., 9 figs.

  10. Constant-Pressure Hydraulic Pump

    Science.gov (United States)

    Galloway, C. W.

    1982-01-01

    Constant output pressure in gas-driven hydraulic pump would be assured in new design for gas-to-hydraulic power converter. With a force-multiplying ring attached to gas piston, expanding gas would apply constant force on hydraulic piston even though gas pressure drops. As a result, pressure of hydraulic fluid remains steady, and power output of the pump does not vary.

  11. [Treatment by external insulin pump].

    Science.gov (United States)

    Clavel, Sylvaine

    2010-12-01

    Since the recent recommendations by the French speaking association for research on diabetes and metabolic illnesses (Alfediam), treatment by insulin pump has found itself in competition with basal-bolus, a procedure using similar injections of insulin which has become a benchmark treatment. The latest Alfediam guidelines focus on defining ways of treating diabetics with an external insulin pump.

  12. High Temperature Thermoacoustic Heat Pump

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-07-15

    Thermoacoustic technology can provide new types of heat pumps that can be deployed in different applications. Thermoacoustic heat pumps can for example be applied in dwellings to generate cooling or heating. Typically, space and water heating makes up about 60% of domestic and office energy consumption. The application of heat pumps can contribute to achieve energy savings and environmental benefits by reducing CO2 and NOx emissions. This paper presents the study of a laboratory scale thermoacoustic-Stirling heat pump operating between 10C and 80C which can be applied in domestics and offices. The heat pump is driven by a thermoacoustic-Stirling engine. The experimental results show that the heat pump pumps 250 W of heat at 60C at a drive ratio of 3.6 % and 200 W at 80C at a drive ratio of 3.5 %. The performance for both cases is about 40% of the Carnot performance. The design, construction, and performance measurements of the heat pump will be presented and discussed.

  13. Ion-Pumping Microbial Rhodopsins

    Directory of Open Access Journals (Sweden)

    Hideki eKandori

    2015-09-01

    Full Text Available Rhodopsins are light-sensing proteins used in optogenetics. The word rhodopsin originates from the Greek words rhodo and opsis, indicating rose and sight, respectively. Although the classical meaning of rhodopsin is the red-colored pigment in our eyes, the modern meaning of rhodopsin encompasses photoactive proteins containing a retinal chromophore in animals and microbes. Animal and microbial rhodopsins possess 11-cis and all-trans retinal, respectively, to capture light in seven transmembrane α-helices, and photoisomerizations into all-trans and 13-cis forms, respectively, initiate each function. Ion-transporting proteins can be found in microbial rhodopsins, such as light-gated channels and light-driven pumps, which are the main tools in optogenetics. Light-driven pumps, such as archaeal H+ pump bacteriorhodopsin (BR and Cl- pump halorhodopsin (HR, were discovered in the 1970s, and their mechanism has been extensively studied. On the other hand, different kinds of H+ and Cl- pumps have been found in marine bacteria, such as proteorhodopsin (PR and Fulvimarina pelagi rhodopsin (FR, respectively. In addition, a light-driven Na+ pump was found, Krokinobacter eikastus rhodopsin 2 (KR2. These light-driven ion-pumping microbial rhodopsins are classified as DTD, TSA, DTE, NTQ and NDQ rhodopsins for BR, HR, PR, FR and KR2, respectively. Recent understanding of ion-pumping microbial rhodopsins is reviewed in this paper.

  14. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  15. Tax Adjusted for Imported Equipment

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    @@ Ministry of Finance, Central Administration of Customs, and State Administration of Taxation of P.R. of China jointly issued a "Notice on the Lists Related to the Interim Provisions on the Adjustment of Import Tax Policy on Major Technical Equipment" (the Notice) on April 13rd to adjust the list of equipment catalog and merchandise attached to the "Interim Provisions on the Import Tax Policy on Major Technical Equipment", as well as the preferential scope and extent of the import tax on a number of major technical equipment.

  16. Insulin pump therapy in pregnancy.

    Science.gov (United States)

    Kesavadev, Jothydev

    2016-09-01

    Control of blood glucose during pregnancy is difficult because of wide variations, ongoing hormonal changes and mood swings. The need for multiple injections, pain at the injection site, regular monitoring and skillful handling of the syringes/pen further makes insulin therapy inconvenient. Insulin pump is gaining popularity in pregnancy because it mimics the insulin delivery of a healthy human pancreas. Multiple guidelines have also recommended the use of insulin pump in pregnancy to maintain the glycaemic control. The pump can release small doses of insulin continuously (basal), or a bolus dose close to mealtime to control the spike in blood glucose after a meal and the newer devices can shut down insulin delivery before the occurrence of hypoglycaemia. Pump insulin of choice is rapid acting analogue insulin. This review underscores the role of insulin pump in pregnancy, their usage, advantages and disadvantages in the light of existing literature and clinic experience.

  17. A data pump for communication

    Science.gov (United States)

    Kang, Myong H.; Moskowitz, Ira S.

    1995-09-01

    As computer systems become more open and interconnected, the need for reliable and secure communication also increases. In this paper, we introduce a communication device, the Pump, that balances the requirements of reliability and security. The Pump provides acknowledgements (ACK's) to the message source to insure reliability. These ACK's are also used to regulate the source to prevent the Pump's buffer from becoming/staying full. This is desirable because once the buffer is filled there exists a huge covert communication channel. The Pump controls the input rate from the source by attempting to slave the input rate to the service rate through the randomized ACK back to the source. An analysis of the covert channel is also presented. The purpose of the covert channel analysis is to provide guidelines for the designer of the Pump to choose appropriate design parameters (e.g., size of buffer) dependent upon the analysis presented in this paper and system requirements.

  18. Peltier heat pumps. Peltiervaermepumpar

    Energy Technology Data Exchange (ETDEWEB)

    Torstensson, H. (Studsvik Energy, Nykoeping (SE))

    1990-06-01

    Todays Peltier devices in heat pump applications gives a low coeffificent of performance. A temperature difference of 40 deg C results in a COP-value of approx. 1.3. Peltier devices are manufactured of alloys composed of heavy elements like tellurium, selenium, bismuth and antimony. These elements thermoelectrical properties, figure of merit are decisive to the performance of the Peltier devices. An upper limit for the figure of merit, ZT, is said to be 2, which at {Delta}T=40 deg C would yield a COP of 2.0 as a maximum. Organic compounds have been investigated with regard to the electric conductivity. Thin film technique have been used for Peltier devices in micro-scale. There are no large-scale applications. The method does not give enhanced termoelectrical properties, but more rational and cheaper manufacturing. (author) (47 refs., 26 figs.).

  19. Self pumping magnetic cooling

    Science.gov (United States)

    Chaudhary, V.; Wang, Z.; Ray, A.; Sridhar, I.; Ramanujan, R. V.

    2017-01-01

    Efficient thermal management and heat recovery devices are of high technological significance for innovative energy conservation solutions. We describe a study of a self-pumping magnetic cooling device, which does not require external energy input, employing Mn-Zn ferrite nanoparticles suspended in water. The device performance depends strongly on magnetic field strength, nanoparticle content in the fluid and heat load temperature. Cooling (ΔT) by ~20 °C and ~28 °C was achieved by the application of 0.3 T magnetic field when the initial temperature of the heat load was 64 °C and 87 °C, respectively. These experiments results were in good agreement with simulations performed with COMSOL Multiphysics. Our system is a self-regulating device; as the heat load increases, the magnetization of the ferrofluid decreases; leading to an increase in the fluid velocity and consequently, faster heat transfer from the heat source to the heat sink.

  20. PLT rotating pumped limiter

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, S.A.; Budny, R.V.; Corso, V.; Boychuck, J.; Grisham, L.; Heifetz, D.; Hosea, J.; Luyber, S.; Loprest, P.; Manos, D.

    1984-07-01

    A limiter with a specially contoured front face and the ability to rotate during tokamak discharges has been installed in a PLT pump duct. These features have been selected to handle the unique particle removal and heat load requirements of ICRF heating and lower-hybrid current-drive experiments. The limiter has been conditioned and commissioned in an ion-beam test stand by irradiation with 1 MW power, 200 ms duration beams of 40 keV hydrogen ions. Operation in PLT during ohmic discharges has proven the ability of the limiter to reduce localized heating caused by energetic electron bombardment and to remove about 2% of the ions lost to the PLT walls and limiters.

  1. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  2. Heat pumps in industry. Pt. 2: Applications

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.M. [Padova Univ., Vicenza (Italy). Ist. di Ingegneria Gestionale

    1995-04-01

    A selection of applications of heat pumps in industry is described, reporting plant lay-outs and performances. The selection includes compression heat pumps at different temperatures, vapour recompression systems, absorption heat pumps and heat transformers. (author)

  3. 78 FR 17890 - Energy Efficiency Program for Commercial and Industrial Equipment: Public Meeting and...

    Science.gov (United States)

    2013-03-25

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, EE-2J... CFR Part 431 RIN 1904-AC82 Energy Efficiency Program for Commercial and Industrial Equipment: Public... Terminal Heat Pumps AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy....

  4. 77 FR 76972 - Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment...

    Science.gov (United States)

    2012-12-31

    ...-displacement, dynamic, or hybrid. A positive-displacement compressor increases the pressure of the intake air... hybrid compressor is some combination of positive- displacement and dynamic compressors. \\1\\ Compressors... improve the efficiency of electric motors and pumps and certain other industrial equipment to conserve...

  5. 40 CFR 270.25 - Specific part B information requirements for equipment.

    Science.gov (United States)

    2010-07-01

    ... on a facility plot plan). (3) Type of equipment (e.g., a pump or pipeline valve). (4) Percent by... to use a control device other than a thermal vapor incinerator, catalytic vapor incinerator, flare, boiler, process heater, condenser, or carbon adsorption system and chooses to use test data to...

  6. Power Product Equipment Technician: Equipment Systems. Teacher Edition. Student Edition.

    Science.gov (United States)

    Hilley, Robert

    This packet contains teacher and student editions on the topic of equipment systems, intended for the preparation of power product equipment technicians. This publication contains seven units: (1) principles of power transmission; (2) mechanical drive systems; (3) principles of fluid power; (4) hydraulic and pneumatic drive systems; (5) wheel and…

  7. HYDRAULIC UNITS FOR DRIVING SYSTEMS OF RUNNING EQUIPMENT IN ROAD CONSTRUCTION MACHINERY

    Directory of Open Access Journals (Sweden)

    A. Ja. Kotlobai

    2016-01-01

    Full Text Available Operational efficiency of multi-functional road construction machines depends on number of working bodies which are simultaneously performing technological operations. Systems for propulsion pto to the running equipment drive and active working bodies of road construction machines are developing in the way of using three-axis hydraulic drives. When designing a hydraulic system for road construction machinery dividing of power flow from propulsion to the running equipment drive and active working bodies is considered as rather essential problem. Leading companies do not pay attention to the development of flow divider designs, preferring to produce more expensive multi-flow pumps. One of the ways to increase efficiency of multi-functional road construction machinery is an implementation of running equipment hydraulic driving system based on a mono-aggregate pump unit which consists of a pump and a volumetric divider of power fluid flow. A principle of volumetric division and summing-up of power fluid flows, technical realization and methodology for calculation of key parameters of discrete flow distributors has been developed on the basis of discrete hydraulics regulations. The paper presents results of mathematical modeling of hydraulic systems equipped with the discrete flow distributor. Analysis of a dual-motor hydraulic drive operation has shown the following results: a discrete flow distributor ensures independent load mode of the current consumer circuit operation from the load mode of the second consumer circuit within a wide range of loads; rational value of working fluid flow discretization parameter is the following value interval k = 4–6, maximum value of parameter efficiency is reached when an angular velocity of a distributor rotor coincides with the angular velocity of a pump shaft; discrete flow distributor provides a possibility to change parameters of hydraulic flow feeding in consumers’ pressure lines within a wide range

  8. Safety evaluation for packaging transportation of equipment for tank 241-C-106 waste sluicing system

    Energy Technology Data Exchange (ETDEWEB)

    Calmus, D.B.

    1994-08-25

    A Waste Sluicing System (WSS) is scheduled for installation in nd waste storage tank 241-C-106 (106-C). The WSS will transfer high rating sludge from single shell tank 106-C to double shell waste tank 241-AY-102 (102-AY). Prior to installation of the WSS, a heel pump and a transfer pump will be removed from tank 106-C and an agitator pump will be removed from tank 102-AY. Special flexible receivers will be used to contain the pumps during removal from the tanks. After equipment removal, the flexible receivers will be placed in separate containers (packagings). The packaging and contents (packages) will be transferred from the Tank Farms to the Central Waste Complex (CWC) for interim storage and then to T Plant for evaluation and processing for final disposition. Two sizes of packagings will be provided for transferring the equipment from the Tank Farms to the interim storage facility. The packagings will be designated as the WSSP-1 and WSSP-2 packagings throughout the remainder of this Safety Evaluation for Packaging (SEP). The WSSP-1 packagings will transport the heel and transfer pumps from 106-C and the WSSP-2 packaging will transport the agitator pump from 102-AY. The WSSP-1 and WSSP-2 packagings are similar except for the length.

  9. Automatic Control of Water Pumping Stations

    Institute of Scientific and Technical Information of China (English)

    Muhannad Alrheeh; JIANG Zhengfeng

    2006-01-01

    Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper, our pumping station is being used for water supply system. This paper is to introduce the idea of pump controller and the important factors that must be considering when we want to design automatic control system of water pumping stations. Then the automatic control circuit with the function of all components will be introduced.

  10. Dental operatory design and equipment.

    Science.gov (United States)

    Floyd, M

    1993-08-01

    Improving and expanding the dental services of a practice can involve purchasing new equipment and even modifying or expanding the physical plant. Operatory design is important to the efficiency with which dental procedures can be performed. Equipment purchases to outfit the dental operatory should be made based on the specific needs and functions of a practice.

  11. GOBERNANZA MULTIFIDUCIARIA DE STAKEHOLDERS: ANÁLISIS COMPARADO DE LA EFICIENCIA DE BANCOS Y CAJAS DE AHORROS. / MULTIFIDUCIARY GOVERNANCE OF STAKEHOLDERS: A COMPARATIVE ANALYSIS OF THE EFFICIENCY OF BANKS AND SAVING BANKS.

    Directory of Open Access Journals (Sweden)

    Jose Luis RETOLAZA

    2012-05-01

    Full Text Available Las cajas de ahorros Españolas son posiblemente el caso más significativo a nivel mundial de entidades multistakeholders, no sólo por su misión, sino también en su gobernanza. La teoría multifiduciaria de los stakeholders plantea, al menos de forma teórica lo que en las cajas de ahorros ha sido una realidad por más de un siglo. Así, las cajas se convierten en un “caso de laboratorio” para analizar la viabilidad e idoneidad de una gobernanza participada por el conjunto de stakeholders de la organización. Nuestra hipótesis es que la gobernanza multistakeholder, así como la orientación hacia los stakeholders, generan un planteamiento estratégico diferente, no centrado en los beneficios. Por tanto, la gobernanza multifiduciaria puede perfectamente ser más ineficiente en relación con indicadores económico-financieros referidos a los shareholders de una entidad. Sin embargo, estas entidades deberían ser más eficientes si se tienen en cuenta indicadores relacionados con la generación de valor social. Con el fin de contrastar la eficiencia relativa hemos utilizando la población de bancos y cajas de España y los datos de 2009, utilizando la técnica de Análisis Envolvente de Datos con objeto de comparar la eficiencia económica, social y global de ambos tipos de entidades. Los resultados indican una diferenciación significativa entre estos dos grupos de entidades financieras en relación con la eficiencia social y económica, si bien no ocurre lo mismo cuando se utiliza la eficiencia global –económica más social-. Por lo que podemos concluir que la eficiencia en la gestión entre inputs y outputs en cajas de ahorros y bancos es similar. / Probably, Spanish savings banks are the most significant worldwide multistakeholders entities, not only because of their mission, but also in their governance. The stakeholder multifiduciary theory, establishes at least theoretically what the saving banks has been a reality for more than

  12. Information technology equipment cooling method

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  13. STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY

    Institute of Scientific and Technical Information of China (English)

    Qiu Baoyun; Huang Jiyan; Yuan Shouqi

    2004-01-01

    Characters of head of low head pump station and the pump shaft power are analyzed. Influence of each single factor on pump shaft power is expressed as change of specific shaft power (non-dimensional) and the probability density function is determined. Influences of multiple factors on pump shaft power are analyzed. Method of calculating none over-loaded probability of motor by integration by successive reductions is put forward and then relation between power spare coefficient and none over-loaded reliability of electric motor is established. Influences of all factors on pump shaft power being considered completely; power spare coefficients of motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-out conditions. Electrical motor power spare coefficients should be chosen as 1.20~1.44, 1.11~1.19, 1.09~1.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much to reasonable choose of electrical motors in large pump stations, increasing reliability of pump units and saving equipment investment.

  14. NaK flow control by electromagnetic pump of the SNAP-10A space nuclear reactor

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo M.; Braz Filho, Francisco A.; Guimaraes, Lamartine N.F., E-mail: eduardo@ieav.cta.br, E-mail: fbraz@ieav.cta.br, E-mail: guimarae@ieav.cta.br [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil)

    2013-07-01

    In the Institute for Advanced Studies (IEAv), were developed, successfully, the first two direct current electromagnetic pumps (DC EM pumps) of Brazil. The first was built with C-type magnet and coils; and the second, with Samarium-Cobalt permanent magnets, for magnetic field generation. Both were tested and performed quite satisfactory. The electromagnetic pump uses the Faraday principle, in which the interaction of the magnetic field and electric current generates the magneto-motive force, which produces the circulation of the fluid. This type of equipment may be used for controlling the liquid metal flow in nuclear space fast reactors. This paper shows the computer programs developed for design and evaluation of DC EM and electromagnetic thermoelectric (EMTE) pumps, the DC EM pump of Samarium-Cobalt magnets data to Mercury loop flow control, the EMTE pump of SNAP space nuclear reactor. It also compares the theoretical results to experimental data of NaK primary loop flow control by electromagnetic thermoelectric pump of the SNAP-10A space nuclear reactor, with satisfactory results, confirming the viability of the electromagnetic pumps evaluation scheme. (author)

  15. Pumping of titanium sapphire laser

    Science.gov (United States)

    Jelínková, H.; Vaněk, P.; Valach, P.; Hamal, K.; Kubelka, J.; Škoda, V.; Jelínek, M.

    1993-02-01

    Two methods of Ti:Sapphire pumping for the generation of tunable laser radiation in the visible region were studied. For coherent pumping, the radiation of the second harmonic of a Nd:YAP laser was used and a maximum output energy of E out=4.5 mJ was reached from the Ti:Sapphire laser. For noncoherent pumping, two different lengths of flashlamp pulses were used and a maximum of E out=300 mJ was obtained. Preliminary estimations of the wavelength range of tunability were made.

  16. Industrial heat pump assessment study

    Science.gov (United States)

    Chappell, R. N.; Priebe, S. J.; Wilfert, G. L.

    1989-03-01

    This report summarizes preliminary studies that assess the potential of industrial heat pumps for reduction of process heating requirements in industries receiving power from the Bonneville Power Administration (BPA). This project was initiated at the request of BPA to determine the potential of industrial heat pumps in BPA's service area. Working from known heat pump principles and from a list of BPA's industrial customers, the authors estimated the fuel savings potential for six industries. Findings indicate that the pulp and paper industry would yield the greatest fuel savings and increased electrical consumption. Assessments presented in this report represent a cooperative effort between The Idaho National Engineering Laboratory (INEL), and Battelle-Northwest Laboratories.

  17. Heat pumps for the home

    CERN Document Server

    Cantor, John

    2013-01-01

    In recent years, heat pumps have emerged as a promising new form of technology with a relatively low environmental impact. Moreover, they have presented householders with an opportunity to reduce their heating bills. Heat pumps can heat a building by 'pumping' heat from either the ground or the air outside: an intriguing process which utilizes principles that are somewhat analogous to those employed in the domestic refrigerator. Armed with the practical information contained in these pages, homeowners will have the necessary knowledge to take advantage of this potentially low-carbon t

  18. Equipe de trabalho

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2014-08-01

    Full Text Available   Equipe de Trabalho 2014 1. Equipe editorial Editor-Chefe Bayardo Bapstista Torres, Instituto de Química - USP, Brasil Eduardo Galembeck, Departamento de Bioquímica Instituto de Biologia UNICAMP, Brasil   Editores Gabriel Gerber Hornink, Depto. Bioquímica, Instituto de Ciências Biomédicas, Universidade - Federal de Alfenas - Unifal-MG, Brasil Vera Maria Treis Trindade, Instituto de Ciências Básicas da Saúde, Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, Brasil   Corpo Editorial Adriana Cassina, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Angel Herráez, Departamento de Bioquímica y Biología molecular, Universidad de Alcalá de Henares, Madrid, Espanha André Amaral Gonçalves Bianco, Universidade Federal de São Paulo (Unifesp, Brasil Denise Vaz de Macedo, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Eneida de Paula, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Guilherme Andrade Marson, Instituto de Química - USP, Brasil Jose Antonio Martinez Oyanedel, Universidad de Concepción, Chile Josep Maria Fernández Novell, Dept. Bioquímica i Biologia Molecular Universitat de Barcelona, Espanha Leila Maria Beltramini, Instituto de Física de São Carlos, Universidade Estadual de São Paulo - USP, Brasil Manuel João da Costa, Escola de Ciências da Saúde, Universidade do Minho, Portugal Maria Lucia Bianconi, Instituto de Bioquímica Médica Universidade Federal do Rio de Janeiro (UFRJ, Brasil María Noel Alvarez, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Miguel Ángel Medina Torres, Department of Molecular Biology & Biochemistry Faculty of Sciences University of Málaga, Espanha Nelma Regina Segnini Bossolan, Instituto de Física de São Carlos, Universidade de São Paulo - USP, Brasil Paulo De Avila

  19. Commercial Submersible Mixing Pump For SRS Tank Waste Removal - 15223

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Mike [Savannah River Remediation, LLC., Aiken, SC (United States); Herbert, James E. [Savannah River Remediation, LLC., Aiken, SC (United States); Scheele, Patrick W. [Savannah River Remediation, LLC., Aiken, SC (United States)

    2015-01-12

    The Savannah River Site Tank Farms have 45 active underground waste tanks used to store and process nuclear waste materials. There are 4 different tank types, ranging in capacity from 2839 m3 to 4921 m3 (750,000 to 1,300,000 gallons). Eighteen of the tanks are older style and do not meet all current federal standards for secondary containment. The older style tanks are the initial focus of waste removal efforts for tank closure and are referred to as closure tanks. Of the original 51 underground waste tanks, six of the original 24 older style tanks have completed waste removal and are filled with grout. The insoluble waste fraction that resides within most waste tanks at SRS requires vigorous agitation to suspend the solids within the waste liquid in order to transfer this material for eventual processing into glass filled canisters at the Defense Waste Processing Facility (DWPF). SRS suspends the solid waste by use of recirculating mixing pumps. Older style tanks generally have limited riser openings which will not support larger mixing pumps, since the riser access is typically 58.4 cm (23 inches) in diameter. Agitation for these tanks has been provided by four long shafted standard slurry pumps (SLP) powered by an above tank 112KW (150 HP) electric motor. The pump shaft is lubricated and cooled in a pressurized water column that is sealed from the surrounding waste in the tank. Closure of four waste tanks has been accomplished utilizing long shafted pump technology combined with heel removal using multiple technologies. Newer style waste tanks at SRS have larger riser openings, allowing the processing of waste solids to be accomplished with four large diameter SLPs equipped with 224KW (300 HP) motors. These tanks are used to process the waste from closure tanks for DWPF. In addition to the SLPs, a 224KW (300 HP) submersible mixer pump (SMP) has also been developed and deployed within older style tanks. The SMPs are product cooled and

  20. DYNAMIC MATHEMATICAL MODELING AND APPLICATION FOR PUMPING SYSTEM PERFORMANCE INTEGRATED EVALUATION

    Institute of Scientific and Technical Information of China (English)

    Chen Hongxun; Wang Jian; Wu Yuejun

    2003-01-01

    A mathematical model is set to evaluate the overall centrifugal pumping system using asynchronous motor as power. This method can be used to affirm system performance according the transform and the aberrance of interior parameters and exterior performance curves so as to give a reference to the equipment amelioration. The analysis of emulation experiment data suggests the model is effectively used.

  1. Improved Modeling of Residential Air Conditioners and Heat Pumps for Energy Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kruis, N. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brandemuehl, M. [Univ. of Colorado, Boulder, CO (United States)

    2013-01-01

    This report presents improved air conditioner and heat pump modeling methods in the context of whole-building simulation tools, with the goal of enabling more accurate evaluation of cost-effective equipment upgrade opportunities and efficiency improvements in residential buildings.

  2. 30 CFR 57.4262 - Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground transformer stations, combustible... and Control Firefighting Equipment § 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms. Transformer stations,...

  3. Safety basis for the 241-AN-107 mixer pump installation and caustic addition

    Energy Technology Data Exchange (ETDEWEB)

    Van Vleet, R.J. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-10-05

    This safety Basis was prepared to determine whether or not the proposed activities of installing a 76 HP jet mixer pump and the addition of approximately 50,000 gallons of 19 M (50:50 wt %) aqueous caustic are within the safety envelope as described by Tank Farms (chapter six of WHC-SD-WM-ISB-001, Rev. 0). The safety basis covers the components, structures and systems for the caustic addition and mixer pump installation. These include: installation of the mixer pump and monitoring equipment; operation of the mixer pump, process monitoring equipment and caustic addition; the pump stand, caustic addition skid, the electrical skid, the video camera system and the two densitometers. Also covered is the removal and decontamination of the mixer pump and process monitoring system. Authority for this safety basis is WHC-IP-0842 (Waste Tank Administration). Section 15.9, Rev. 2 (Unreviewed Safety Questions) of WHC-IP-0842 requires that an evaluation be performed for all physical modifications.

  4. Experimental and numerical analysis of unsteady behaviour of high efficiency mixed-flow pump

    Directory of Open Access Journals (Sweden)

    Sedlář Milan

    2014-03-01

    Full Text Available This work deals with the experimental and numerical investigation of cavitating and noncavitating flow inside a mixed-flow pump and its influence on performance curves of this pump. The experimental research has been carried out in the closed horizontal loop with the main tank capacity of 35 m3. The loop is equipped with both the compressor and the vacuum pump capable of creating different pressure levels while maintaining constant volume flow rate. Pump investigated in this project has been equipped with transparent windows, which enabled the visualization of flow and cavitation phenomena for a wide range of flow conditions. A comprehensive CFD analysis of tested pump has been done both in the cavitating and noncavitating regimes. The ANSYS CFX commercial CFD package has been used to solve URANS equations together with the Rayleigh-Plesset model and the SST-SAS turbulence model. Both the experimental research and the CFD analysis have provided a good illustration of the flow structures inside the pump and their dynamics for a wide range of flow rates and NPSH values. Flow and cavitation instabilities have been detected at suboptimal flow rates which correspond to increased values of noise and vibrations. The calculated results agree well with the measurements.

  5. Experimental and numerical analysis of unsteady behaviour of high efficiency mixed-flow pump

    Science.gov (United States)

    Sedlář, Milan; Komárek, Martin; Vyroubal, Michal; Doubrava, Vít; Varchola, Michal; Hlbočan, Peter

    2014-03-01

    This work deals with the experimental and numerical investigation of cavitating and noncavitating flow inside a mixed-flow pump and its influence on performance curves of this pump. The experimental research has been carried out in the closed horizontal loop with the main tank capacity of 35 m3. The loop is equipped with both the compressor and the vacuum pump capable of creating different pressure levels while maintaining constant volume flow rate. Pump investigated in this project has been equipped with transparent windows, which enabled the visualization of flow and cavitation phenomena for a wide range of flow conditions. A comprehensive CFD analysis of tested pump has been done both in the cavitating and noncavitating regimes. The ANSYS CFX commercial CFD package has been used to solve URANS equations together with the Rayleigh-Plesset model and the SST-SAS turbulence model. Both the experimental research and the CFD analysis have provided a good illustration of the flow structures inside the pump and their dynamics for a wide range of flow rates and NPSH values. Flow and cavitation instabilities have been detected at suboptimal flow rates which correspond to increased values of noise and vibrations. The calculated results agree well with the measurements.

  6. Method for controlling powertrain pumps

    Science.gov (United States)

    Sime, Karl Andrew; Spohn, Brian L; Demirovic, Besim; Martini, Ryan D; Miller, Jean Marie

    2013-10-22

    A method of controlling a pump supplying a fluid to a transmission includes sensing a requested power and an excess power for a powertrain. The requested power substantially meets the needs of the powertrain, while the excess power is not part of the requested power. The method includes sensing a triggering condition in response to the ability to convert the excess power into heat in the transmission, and determining that an operating temperature of the transmission is below a maximum. The method also includes determining a calibrated baseline and a dissipation command for the pump. The calibrated baseline command is configured to supply the fluid based upon the requested power, and the dissipation command is configured to supply additional fluid and consume the excess power with the pump. The method operates the pump at a combined command, which is equal to the calibrated baseline command plus the dissipation command.

  7. High Performance Space Pump Project

    Data.gov (United States)

    National Aeronautics and Space Administration — PDT is proposing a High Performance Space Pump based upon an innovative design using several technologies. The design will use a two-stage impeller, high temperature...

  8. Heat pumps at the maltings

    Energy Technology Data Exchange (ETDEWEB)

    1987-11-01

    Heat pumps have halved the energy costs of producing finished malt at two of the country's maltsters. The fuel-fired kilning processes described are now performed by heat pumps with considerable energy and production benefits at the maltings of J.P. Simpson and Co. (Alnwick) Ltd, in Tivetshall St Margaret, Norfolk, and of Munton and Fison Plc of Stowmarket, Suffolk. The heat pump system installed at the Station Malting of J.P. Simpson was devised by the Electricity Council Research Centre at Capenhurst near Chester. Energy cost benefits of Pound 6,000 a month are being realised at Simpsons, but there is the added benefit that the system has been designed to provide conditioned air to the germination cycle to ensure that the correct temperature is maintained throughout the year. At the Cedars factory of Munton and Fison, heat pumps were used on a trial basis for plant micropropagation and for a fish farming unit.

  9. Magnetic heat pump flow director

    Science.gov (United States)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  10. Transverse pumped laser amplifier architecture

    Science.gov (United States)

    Bayramian, Andrew James; Manes, Kenneth; Deri, Robert; Erlandson, Al; Caird, John; Spaeth, Mary

    2013-07-09

    An optical gain architecture includes a pump source and a pump aperture. The architecture also includes a gain region including a gain element operable to amplify light at a laser wavelength. The gain region is characterized by a first side intersecting an optical path, a second side opposing the first side, a third side adjacent the first and second sides, and a fourth side opposing the third side. The architecture further includes a dichroic section disposed between the pump aperture and the first side of the gain region. The dichroic section is characterized by low reflectance at a pump wavelength and high reflectance at the laser wavelength. The architecture additionally includes a first cladding section proximate to the third side of the gain region and a second cladding section proximate to the fourth side of the gain region.

  11. Use of an Irrigation Pump System in Arthroscopic Procedures.

    Science.gov (United States)

    Hsiao, Mark S; Kusnezov, Nicholas; Sieg, Ryan N; Owens, Brett D; Herzog, Joshua P

    2016-05-01

    Since its inception, arthroscopic surgery has become widely adopted among orthopedic surgeons. It is therefore important to have an understanding of the basic principles of arthroscopy. Compared with open techniques, arthroscopic procedures are associated with smaller incisions, less structural damage, improved intra-articular visualization, less pain in the immediate postoperative period, and faster recovery for patients. Pump systems used for arthroscopic surgery have evolved over the years to provide improved intraoperative visualization. Gravity flow systems were described first and are still commonly used today. More recently, automated pump systems with pressure or dual pressure and volume control have been developed. The advantages of automated irrigation systems over gravity irrigation include a more consistent flow, a greater degree of joint distention, improved visualization especially with motorized instrumentation, decreased need for tourniquet use, a tamponade effect on bleeding, and decreased operative time. Disadvantages include the need for additional equipment with increased cost and maintenance, the initial learning curve for the surgical team, and increased risk of extra-articular fluid dissection and associated complications such as compartment syndrome. As image quality and pump systems improve, so does the list of indications including diagnostic and treatment modalities to address intra-articular pathology of the knee, shoulder, hip, wrist, elbow, and ankle joints. This article reviews the current literature and presents the history of arthroscopy, basic science of pressure and flow, types of irrigation pumps and their functions, settings, applications, and complications. [Orthopedics. 2016; 39(3):e474-e478.].

  12. TRANSPORT AND EMPLACEMENT EQUIPMENT DESCRIPTIONS

    Energy Technology Data Exchange (ETDEWEB)

    NA

    1997-09-29

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) Transport and Emplacement in the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. The Transport and Emplacement equipment described in this document consists of the following: (1) WP Transporter; (2) Reusable Rail Car; (3) Emplacement Gantry; (4) Gantry Carrier; and (5) Transport Locomotive.

  13. Pump control system for windmills

    Science.gov (United States)

    Avery, Don E.

    1983-01-01

    A windmill control system having lever means, for varying length of stroke of the pump piston, and a control means, responsive to the velocity of the wind to operate the lever means to vary the length of stroke and hence the effective displacement of the pump in accordance with available wind energy, with the control means having a sensing member separate from the windmill disposed in the wind and displaceable thereby in accordance with wind velocity.

  14. Diode-pumped dye laser

    Science.gov (United States)

    Burdukova, O. A.; Gorbunkov, M. V.; Petukhov, V. A.; Semenov, M. A.

    2016-10-01

    This letter reports diode pumping for dye lasers. We offer a pulsed dye laser with an astigmatism-compensated three-mirror cavity and side pumping by blue laser diodes with 200 ns pulse duration. Eight dyes were tested. Four dyes provided a slope efficiency of more than 10% and the highest slope efficiency (18%) was obtained for laser dye Coumarin 540A in benzyl alcohol.

  15. Optical Pumping of Molecular Gases

    Science.gov (United States)

    1976-04-01

    in Hg, excimer system. IV. OPTICALLY PUMPED Na Ř The details of our optical pumping studies of Na2 are presented in Appendix I. The study showed that...inversitot In IM -Second set of linesn have. tentatively been Identified ats D asid A btuu~t-sa A-band tratsitiwts termiuiatitig, oilt*n 3,4,5 for J0 TO HELIUM

  16. 14 CFR 29.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 29.991 Section 29.991... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System Components § 29.991 Fuel pumps. (a) Compliance with § 29.955 must not be jeopardized by failure of— (1) Any one pump except pumps that...

  17. 14 CFR 27.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 27.991 Section 27.991... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System Components § 27.991 Fuel pumps. Compliance with § 27.955 may not be jeopardized by failure of— (a) Any one pump except pumps that are approved...

  18. 46 CFR 182.520 - Bilge pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Bilge pumps. 182.520 Section 182.520 Shipping COAST...) MACHINERY INSTALLATION Bilge and Ballast Systems § 182.520 Bilge pumps. (a) A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to...

  19. 46 CFR 105.20-10 - Pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pumps. 105.20-10 Section 105.20-10 Shipping COAST GUARD... DISPENSING PETROLEUM PRODUCTS Specific Requirements-Cargo Tanks § 105.20-10 Pumps. (a) Pumps for cargo... discharge side of pump if the pressure under shutoff conditions exceeds 60 pounds. When a relief valve...

  20. 14 CFR 25.991 - Fuel pumps.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel pumps. 25.991 Section 25.991... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.991 Fuel pumps. (a) Main pumps. Each fuel pump required for proper engine operation, or required to meet the fuel...

  1. 46 CFR 118.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 118.300 Section 118.300 Shipping COAST GUARD... Fire pumps. (a) A self priming, power driven fire pump must be installed on each vessel. (b) On a..., the fire pump must be capable of delivering a single hose stream from the highest hydrant, through...

  2. METHOD FOR OPTIMIZING THE ENERGY OF PUMPS

    NARCIS (Netherlands)

    Skovmose Kallesøe, Carsten; De Persis, Claudio

    2013-01-01

    The device for energy-optimization on operation of several centrifugal pumps controlled in rotational speed, in a hydraulic installation, begins firstly with determining which pumps as pilot pumps are assigned directly to a consumer and which pumps are hydraulically connected in series upstream of t

  3. Method for optimising the energy of pumps

    NARCIS (Netherlands)

    Skovmose Kallesøe, Carsten; De Persis, Claudio

    2011-01-01

    The method involves determining whether pumps (pu1, pu5) are directly assigned to loads (v1, v3) as pilot pumps (pu2, pu3) and hydraulically connected upstream of the pilot pumps. The upstream pumps are controlled with variable speed for energy optimization. Energy optimization circuits are selected

  4. Electron beam pumped semiconductor laser

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor)

    2009-01-01

    Electron-beam-pumped semiconductor ultra-violet optical sources (ESUVOSs) are disclosed that use ballistic electron pumped wide bandgap semiconductor materials. The sources may produce incoherent radiation and take the form of electron-beam-pumped light emitting triodes (ELETs). The sources may produce coherent radiation and take the form of electron-beam-pumped laser triodes (ELTs). The ELTs may take the form of electron-beam-pumped vertical cavity surface emitting lasers (EVCSEL) or edge emitting electron-beam-pumped lasers (EEELs). The semiconductor medium may take the form of an aluminum gallium nitride alloy that has a mole fraction of aluminum selected to give a desired emission wavelength, diamond, or diamond-like carbon (DLC). The sources may be produced from discrete components that are assembled after their individual formation or they may be produced using batch MEMS-type or semiconductor-type processing techniques to build them up in a whole or partial monolithic manner, or combination thereof.

  5. Jarvik 2000 pump technology and miniaturization.

    Science.gov (United States)

    Jarvik, Robert

    2014-01-01

    Blood-pump miniaturization has made amazing progress, reducing the pump diameter to one-tenth of the size of previous positive displacement pumps. In particular, axial-flow-pump technology allows tiny pumps running at high speeds to deliver from 2 to 10 L/min. A review of the background inventions of the Jarvik 2000 technology is presented, together with the reason that making pumps smaller than demanded by the particular application for which they are designed is counterproductive. Pump miniaturization is nearing its practical limit. The optimization of performance and patient outcomes should remain our primary design goal.

  6. Numerical Analysis of the Transient Behaviour of a Variable Speed Pump-Turbine during a Pumping Power Reduction Scenario

    Directory of Open Access Journals (Sweden)

    Giorgio Pavesi

    2016-07-01

    Full Text Available To achieve the carbon free electricity generation target for 2050, the penetration of renewable energy sources should further increase. To address the impacts of their unpredictable and intermittent characteristics on the future electricity grid, Pumped Hydro Energy Storage (PHES plants should enhance their regulation capability by extending their continuous operating range far beyond the optimal normal working range. However, for the time being, the regulation capability of the new generation of PHES, equipped with reversible pump-turbines due to their cost-effectiveness, is limited at part load by instability problems. The aim of this paper is to analyse, during a pumping power reduction scenario, the onset and development of unsteady phenomena leading to unstable behaviour. A 3D transient numerical simulation was carried out on the first stage of a variable-speed two-stage pump-turbine from full load to the unstable operating zone by progressively reducing the speed from 100% to 88% rpm corresponding to a power reduction from full load to about 60% with a ramp rate of 1.5% per s. Two three-dimensional unsteady flow structures affecting the return channel and the wicket gates at the end of the first stage were identified and their evolution in the power regulation scenario was fluid-dynamically and spectrally characterized to determine the fluid-dynamical conditions causing the head drop in the hump zone.

  7. ENERGY STAR Certified Imaging Equipment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Imaging Equipment that are effective as of...

  8. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  9. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  10. Comparison of solar powered water pumping systems which use diaphragm pumps

    Science.gov (United States)

    Four solar photovoltaic (PV) powered diaphragm pumps were tested at different simulated pumping depths at the USDA-ARS Conservation and Production Research Laboratory near Bushland, Texas. Two of the pumps were designed for intermediate pumping depths (30 to 70 meters), and the other two pumps were...

  11. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  12. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  13. Ahorro de dinero y de energía mediante la instalación de una conducción termoplástica en una refinería, EE.UU.

    Directory of Open Access Journals (Sweden)

    Editorial, Equipo

    1979-11-01

    Full Text Available This article describes the method used by and oil refinery to save some two hundred thousand dollars in the replacement of a seriously damaged stretch of a pipeline carrying salt water refrigerant. This substantial saving was obtained by installing high density polyethylene pressure pipe as a cover around the damaged pipe section. The same type of piping can be used in other industries (pulp and paper mills, Chemical processes pollution control, mining, textile mills, etc. where worm or abrasion corrosion damaged pipes can be found.

    Este artículo describe el método por el cual una refinería pudo ahorrarse unos doce millones de pesetas en la operación de repuesto de un tramo muy deteriorado de una conducción que transporta agua salada refrigerante. Este ahorro substancial se obtuvo gracias al uso de futras de presión de polietileno, de alta densidad, como revestimiento de la sección deteriorada de la tutoría. El mismo tipo de tubería se puede emplear también en otras industrias (pastas, papel, procesos químicos, control de polución, minería, textil, etcétera donde existan conducciones desgastadas o deterioradas por corrosión o abrasión.

  14. Military GPS User Equipment (MGUE)

    Science.gov (United States)

    2015-04-29

    Space and Missile Systems Center Military GPS User Equipment (MGUE) Lt Col James “Mutt” Wilson Program Manager 29 Apr 15 Information contained in...SUBTITLE Military GPS User Equipment (MGUE) 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK...SUPPLEMENTARY NOTES Presented at the GPS Partnership Council 2015 (GPSPC15), held April 29 to May 1, 2015, at the Los Angeles AFB, CA. 14. ABSTRACT

  15. Nuclear Weapon and Military Equipment

    Directory of Open Access Journals (Sweden)

    N. Natarajan

    1985-10-01

    Full Text Available Military equipment must survive a, nuclear attack if enough personnel required to operate them remain combat effective. To achieve this goal, the criteria that determine equipment survivability should be established and any new design should incorporate these criteria to evolve a hardened design. An analysis of the overall response by considering the response to each individual nuclear environment can result in a balanced overall hardened system. The paper discusses the criteria required to be known.

  16. Experimental Realization of a Quantum Spin Pump

    DEFF Research Database (Denmark)

    Watson, Susan; Potok, R.; M. Marcus, C.;

    2003-01-01

    We demonstrate the operation of a quantum spin pump based on cyclic radio-frequency excitation of a GaAs quantum dot, including the ability to pump pure spin without pumping charge. The device takes advantage of bidirectional mesoscopic fluctuations of pumped current, made spin......-dependent by the application of an in-plane Zeeman field. Spin currents are measured by placing the pump in a focusing geometry with a spin-selective collector....

  17. Research on Selection of Equipment Maintenance Modes

    Institute of Scientific and Technical Information of China (English)

    SHANG Wen-li; SHI Hai-bo; HE Bai-tao

    2006-01-01

    The development of equipment maintenance management is introduced, and equipment maintenance concept is defined. Equipment maintenance modes are classified, analyzed and compared, which merits and demerits are pointed out. At last, a decision-making frame to select equipment maintenance modes is advanced, and steps to select and implement equipment maintenance are given.

  18. 14 CFR 25.1415 - Ditching equipment.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ditching equipment. 25.1415 Section 25.1415... STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Safety Equipment § 25.1415 Ditching equipment. (a) Ditching equipment used in airplanes to be certificated for ditching under § 25.801, and required by...

  19. Groundwater heat pumps with turbines for the return water; Grundwasser-Waermepumpe mit Rueckgabe-Turbinierung

    Energy Technology Data Exchange (ETDEWEB)

    Eberhard, M.

    2007-09-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on improvements in the efficiency of a ground water heat pump installation in an office building. The water return well was equipped with a turbine. In this installation, the ground water is pumped up from a depth of 45 meters which means that a lot of electricity is needed for the pumping of the water. Coefficients of performance of the system are quoted for the situation with and without the turbine. The conversion of a pump for use as a turbine is commented on. The construction of a specially developed turbine with reduced electricity consumption is suggested. Seasonal performance data of the system is provided in tabular form.

  20. Assessment of solar-assisted gas-fired heat pump systems

    Science.gov (United States)

    Lansing, F. L.

    1981-01-01

    As a possible application for the Goldstone Energy Project, the performance of a 10 ton heat pump unit using a hybrid solar gas energy source was evaluated in an effort to optimize the solar collector size. The heat pump system is designed to provide all the cooling and/or heating requirements of a selected office building. The system performance is to be augmented in the heating mode by utilizing the waste heat from the power cycle. A simplified system analysis is described to assess and compute interrrelationships of the engine, heat pump, and solar and building performance parameters, and to optimize the solar concentrator/building area ratio for a minimum total system cost. In addition, four alternative heating cooling systems, commonly used for building comfort, are described; their costs are compared, and are found to be less competitive with the gas solar heat pump system at the projected solar equipment costs.