  1. Centrifugal blood pump for temporary ventricular assist devices with low priming and ceramic bearings.

    Science.gov (United States)

    Leme, Juliana; da Silva, Cibele; Fonseca, Jeison; da Silva, Bruno Utiyama; Uebelhart, Beatriz; Biscegli, José F; Andrade, Aron

    2013-11-01

    A new model of centrifugal blood pump for temporary ventricular assist devices has been developed and evaluated. The design of the device is based on centrifugal pumping principles and the usage of ceramic bearings, resulting in a pump with reduced priming (35 ± 2 mL) that can be applied for up to 30 days. Computational fluid dynamic (CFD) analysis is an efficient tool to optimize flow path geometry, maximize hydraulic performance, and minimize shear stress, consequently decreasing hemolysis. Initial studies were conducted by analyzing flow behavior with different impellers, aiming to determine the best impeller design. After CFD studies, rapid prototyping technology was used for production of pump prototypes with three different impellers. In vitro experiments were performed with those prototypes, using a mock loop system composed of Tygon tubes, oxygenator, digital flow meter, pressure monitor, electronic driver, and adjustable clamp for flow control, filled with a solution (1/3 water, 1/3 glycerin, 1/3 alcohol) simulating blood viscosity and density. Flow-versus-pressure curves were obtained for rotational speeds of 1000, 1500, 2000, 2500, and 3000 rpm. As the next step, the CFD analysis and hydrodynamic performance results will be compared with the results of flow visualization studies and hemolysis tests.

  2. BIOMATERIALS FOR ROTARY BLOOD PUMPS

    NARCIS (Netherlands)

    VANOEVEREN, W

    1995-01-01

    Rotary blood pumps are used for cardiac assist and cardiopulmonary support since mechanical blood damage is less than with conventional roller pumps. The high shear rate in the rotary pump and the reduced anticoagulation of the patient during prolonged pumping enforces high demands on the biocompati

  3. Method for Reducing Pumping Damage to Blood

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor); Akkerman, James W. (Inventor); Aber, Gregory S. (Inventor); VanDamm, George Arthur (Inventor); Bacak, James W. (Inventor); Svejkovsky, Robert J. (Inventor); Benkowski, Robert J. (Inventor)

    1997-01-01

    Methods are provided for minimizing damage to blood in a blood pump wherein the blood pump comprises a plurality of pump components that may affect blood damage such as clearance between pump blades and housing, number of impeller blades, rounded or flat blade edges, variations in entrance angles of blades, impeller length, and the like. The process comprises selecting a plurality of pump components believed to affect blood damage such as those listed herein before. Construction variations for each of the plurality of pump components are then selected. The pump components and variations are preferably listed in a matrix for easy visual comparison of test results. Blood is circulated through a pump configuration to test each variation of each pump component. After each test, total blood damage is determined for the blood pump. Preferably each pump component variation is tested at least three times to provide statistical results and check consistency of results. The least hemolytic variation for each pump component is preferably selected as an optimized component. If no statistical difference as to blood damage is produced for a variation of a pump component, then the variation that provides preferred hydrodynamic performance is selected. To compare the variation of pump components such as impeller and stator blade geometries, the preferred embodiment of the invention uses a stereolithography technique for realizing complex shapes within a short time period.

  4. [Hemodynamic analysis of a centrifugal blood pump].

    Science.gov (United States)

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels.

  5. A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head.

    Science.gov (United States)

    Hijikata, Wataru; Shinshi, Tadahiko; Asama, Junichi; Li, Lichuan; Hoshi, Hideo; Takatani, Setsuo; Shimokohbe, Akira

    2008-07-01

    A magnetically levitated centrifugal blood pump (MedTech Dispo) has been developed for use in a disposable extracorporeal system. The design of the pump is intended to eliminate mechanical contact with the impeller, to facilitate a simple disposable mechanism, and to reduce the blood-heating effects that are caused by motors and magnetic bearings. The bearing rotor attached to the impeller is suspended by a two degrees-of-freedom controlled radial magnetic bearing stator, which is situated outside the rotor. In the space inside the ringlike rotor, a magnetic coupling disk is placed to rotate the rotor and to ensure that the pump head is thermally isolated from the motor. In this system, the rotor can exhibit high passive stiffness due to the novel design of the closed magnetic circuits. The disposable pump head, which has a priming volume of 23 mL, consists of top and bottom housings, an impeller, and a rotor with a diameter of 50 mm. The pump can provide a head pressure of more than 300 mm Hg against a flow of 5 L/min. The normalized index of hemolysis of the MedTech Dispo is 0.0025 +/- 0.0005 g/100 L at 5 L/min against 250 mm Hg. This is one-seventh of the equivalent figure for a Bio Pump BPX-80 (Medtronic, Inc., Minneapolis, MN, USA), which has a value of 0.0170 +/- 0.0096 g/100 L. These results show that the MedTech Dispo offers high pumping performance and low blood trauma.

  6. Fluid Dynamics in Rotary Piston Blood Pumps.

    Science.gov (United States)

    Wappenschmidt, Johannes; Sonntag, Simon J; Buesen, Martin; Gross-Hardt, Sascha; Kaufmann, Tim; Schmitz-Rode, Thomas; Autschbach, Ruediger; Goetzenich, Andreas

    2017-03-01

    Mechanical circulatory support can maintain a sufficient blood circulation if the native heart is failing. The first implantable devices were displacement pumps with membranes. They were able to provide a sufficient blood flow, yet, were limited because of size and low durability. Rotary pumps have resolved these technical drawbacks, enabled a growing number of mechanical circulatory support therapy and a safer application. However, clinical complications like gastrointestinal bleeding, aortic insufficiency, thromboembolic complications, and impaired renal function are observed with their application. This is traced back to their working principle with attenuated or non-pulsatile flow and high shear stress. Rotary piston pumps potentially merge the benefits of available pump types and seem to avoid their complications. However, a profound assessment and their development requires the knowledge of the flow characteristics. This study aimed at their investigation. A functional model was manufactured and investigated with particle image velocimetry. Furthermore, a fluid-structure interaction computational simulation was established to extend the laboratory capabilities. The numerical results precisely converged with the laboratory measurements. Thus, the in silico model enabled the investigation of relevant areas like gap flows that were hardly feasible with laboratory means. Moreover, an economic method for the investigation of design variations was established.

  7. Hemolysis generation from a novel, linear positive displacement blood pump for cardiopulmonary bypass on a six kilogram piglet: a preliminary report.

    Science.gov (United States)

    Lawson, D Scott; Eilers, Derek; Osorio Lujan, Suzanne; Bortot, Maria; Jaggers, James

    2017-05-01

    Current blood pumps used for cardiopulmonary bypass generally fall into two different pump design categories; non-occlusive centrifugal pumps and occlusive, positive-displacement roller pumps. The amount of foreign surface area of extracorporeal circuits correlates with post-operative morbidity due to systemic inflammation, leading to a push for technology that reduces the amount of foreign surfaces. Current roller pumps are bulky and the tubing forms an arc in the pumping chamber (raceway), positioning the inlet 360 degrees from the outlet, making it very difficult to place the pump closer to the patient and to efficiently reduce tubing length. These challenges put existing roller pumps at a disadvantage for use in a compact cardiopulmonary bypass circuit. Centrifugal blood pumps are easier to incorporate into miniature circuit designs. However, the prime volumes of current centrifugal pump designs are large, especially for pediatric extracorporeal circuits where the prime volumes are too great to be of clinical value. We describe a preliminary report on a novel, occlusive, linear, single-helix, positive-displacement blood pump which allows for decreased prime volume and surface area of the extracorporeal circuit. This new experimental pump design was used to perfuse a 6 kilogram piglet with a pediatric cardiopulmonary bypass circuit for two hours of continuous use. Blood samples were obtained every thirty minutes and assayed for plasma free hemolysis generation. The results from this initial experiment showed low plasma free hemoglobin generation and encourages the authors to further develop this concept.

  8. A multiple disk centrifugal pump as a blood flow device.

    Science.gov (United States)

    Miller, G E; Etter, B D; Dorsi, J M

    1990-02-01

    A multiple disk, shear force, valveless centrifugal pump was studied to determine its suitability as a blood flow device. A pulsatile version of the Tesla viscous flow turbine was designed by modifying the original steady flow pump concept to produce physiological pressures and flows with the aid of controlling circuitry. Pressures and flows from this pump were compared to a Harvard Apparatus pulsatile piston pump. Both pumps were connected to an artificial circulatory system. Frequency and systolic duration were varied over a range of physiological conditions for both pumps. The results indicated that the Tesla pump, operating in a pulsatile mode, is capable of producing physiologic pressures and flows similar to the Harvard pump and other pulsatile blood pumps.

  9. A straight path centrifugal blood pump concept in the Capiox centrifugal pump.

    Science.gov (United States)

    Kijima, T; Oshiyama, H; Horiuchi, K; Nogawa, A; Hamasaki, H; Amano, N; Nojiri, C; Fukasawa, H; Akutsu, T

    1993-07-01

    This article describes comparative studies of a newly developed "straight path" centrifugal pump (Capiox centrifugal pump) targeted for open-heart surgery and circulatory support. A unique straight path design of the rotor was very effective in reducing the pump's rotational speed and prime volume. This pump was evaluated for hydraulics, hemolysis, depriming characteristics, cavitation, and heat generation. Two commercially available centrifugal pumps, the Biomedicus cone-type pump and the Sarns 3M impeller-type pump, were used as controls. The new pump required the lowest pump speed to produce the same flow rates under the same pressure loads and demonstrated the lowest hemolysis and the lowest temperature rise with the outlet clamped. The air volume required to deprime the new pump was one-third to one-half that for the other pumps, and no sign of cavitation was observed even if a small amount of air was introduced to the pump inlet under a negative pressure of 200 mm Hg.

  10. Performance of a newly developed implantable centrifugal blood pump.

    Science.gov (United States)

    Tsukiya, T; Taenaka, Y; Tatsumi, E; Takano, H

    2001-01-01

    The performance of the newly developed implantable centrifugal blood pump was investigated in vitro. The pump was developed with the end goal of building a versatile system that includes a left ventricular assist system with an internal secondary battery or an implantable biventricular assist system with two implantable blood pumps. The hydrodynamic characteristics and efficiency of the blood pump were evaluated, and the mechanical damage to the blood caused by the blood pump was assessed through a hemolysis test using fresh goat blood. The pump could generate 120 mm Hg at a flow rate of 5 L/min and a motor speed of 2,500 rpm. The electric input power to the pump was approximately 5 watts under these working conditions. The hemolysis caused by the pump was a bit higher than that by the former model, but stayed within an acceptable range. Performance of the pump in vitro was considered sufficient for a left ventricular assist device, although further design improvement is necessary in terms of hemolysis and system efficiency to improve biocompatibility of the pump.

  11. A teaspoon pump for pumping blood with high hydraulic efficiency and low hemolysis potential.

    Science.gov (United States)

    Dame, D

    1996-06-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required.

  12. A self-priming, roller-free, miniature, peristaltic pump operable with a single, reciprocating actuator

    Science.gov (United States)

    Shkolnikov, Viktor; Ramunas, John; Santiago, Juan G.

    2013-01-01

    We present a design for a miniature self-priming peristaltic pump actuated with a single linear actuator, and which can be manufactured using conventional materials and methods. The pump is tolerant of bubbles and particles and can pump liquids, foams, and gases. We explore designs actuated by a motor (in depth) and a shape memory alloy (briefly); and briefly present a manually actuated version. The pump consists of a Delrin acetal plastic body with two integrated valves, a flexible silicone tube, and an actuator. Pumping is achieved as the forward motion of the actuator first closes the upstream valve, and then compresses a section of the tube. The increased internal pressure opens a downstream burst valve to expel the fluid. Reduced pressure in the pump tube allows the downstream valve to close, and removal of actuator force allows the upstream valve and pump tube to open, refilling the pump. The motor actuated design offers a linear dependence of flow rate on voltage in the range of 1.75–3 V. Flow rate decreases from 780 μl/min with increasing back pressure up to the maximum back pressure of 48 kPa. At 3 V and minimum back pressure, the pump consumes 90 mW. The shape memory alloy actuated design offers a 5-fold size and 4-fold weight reduction over the motor design, higher maximum back pressure, and substantial insensitivity of flow rate to back pressure at the cost of lower power efficiency and flow rate. The manually actuated version is simpler and appropriate for applications unconstrained by actuation distance. PMID:24672145

  13. Development of a miniature intraventricular axial flow blood pump.

    Science.gov (United States)

    Yamazaki, K; Umezu, M; Koyanagi, H; Outa, E; Ogino, S; Otake, Y; Shiozaki, H; Fujimoto, T; Tagusari, O; Kitamura, M

    1993-01-01

    A new intraventricular axial flow blood pump has been designed and developed as a totally implantable left ventricular assist device (LVAD). This pump consists of an impeller combined with a guide-vane, a tube housing, and a DC motor. The pump is introduced into the LV cavity through the LV apex, and the outlet cannula is passed antegrade across the aortic valve. Blood is withdrawn from the LV through the inlet ports at the pump base, and discharged to the ascending aorta. Our newly developed axial flow pump system has the following advantages: 1) it is a simple and compact system, 2) minimal blood stasis both in the device and the LV cavity, 3) minimal blood contacting surface of the pump, 4) easy accessibility with a less invasive surgical procedure, and 5) low cost. A pump flow > 5 L/min was obtained against 100 mmHg differential pressure in the mock circulatory system. The pump could produce a passive pulsatile flow effect with a beating heart more efficiently than other non-pulsatile pumps because of minimal pressure drop and inertia along the bypass tract. Anatomic fit studies using dissected hearts of dilated cardiomyopathy (DCM) cadavers showed that this pump could smoothly pass through the aortic valve without any interference with mitral valve function. Recently, a dynamic pressure groove bearing and a miniature lip seal have been developed. The dynamic pressure groove bearing has a simple structure and acts as a pressure resistant sealing mechanism.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Timing of adding blood to prime affects inflammatory response to neonatal cardiopulmonary bypass.

    Science.gov (United States)

    Schmidt, Benjamin S; Jordan, James E; Lane, Magan R; DiPasquale, Vanessa M; Graf, Lori P; Ootaki, Yoshio; Ungerleider, Ross M

    2016-07-08

    Complications from systemic inflammation are reported in neonates following exposure to cardiopulmonary bypass. Although the use of asanguinous primes can reduce these complications, in neonates, this can result in significant haemodilution, requiring addition of blood. This study investigates whether the addition of blood after institution of bypass alters the inflammatory response compared with a blood prime. Neonatal swine were randomised into four groups: blood prime, blood after bypass but before cooling, blood after cooling but before low flow, and blood after re-warming. All groups were placed on central bypass, cooled, underwent low flow, and then re-warmed for a total bypass time of 2 hours. Although haematocrit values between groups varied throughout bypass, all groups ended with a similar value. Although they spent time with a lower haematocrit, asanguinous prime groups did not have elevated lactate levels at the end of bypass compared with blood prime. Asanguinous primes released less tumour necrosis factor α than blood primes (p=0.023). Asanguinous primes with blood added on bypass produced less interleukin 10 and tumour necrosis factor α (p=0.006, 0.019). Animals receiving blood while cool also showed less interleukin 10 and tumour necrosis factor α production than those that received blood warm (p=0.026, 0.033). Asanguinous primes exhibited less oedema than blood primes, with the least body weight gain noted in the end cool group (p=0.011). This study suggests that using an asanguinous prime for neonates being cooled to deep hypothermia is practical, and the later addition of blood reduces inflammation.

  15. Priming

    DEFF Research Database (Denmark)

    Conrath, Uwe; Beckers, Gerold J.M.; Flors, Victor

    2006-01-01

    Infection of plants by necrotizing pathogens or colonization of plant roots with certain beneficial microbes causes the induction of a unique physiological state called "priming." The primed state can also be induced by treatment of plants with various natural and synthetic compounds. Primed plants...... display either faster, stronger, or both activation of the various cellular defense responses that are induced following attack by either pathogens or insects or in response to abiotic stress. Although the phenomenon has been known for decades, most progress in our understanding of priming has been made...... over the past few years. Here, we summarize the current knowledge of priming in various induced-resistance phenomena in plants...

  16. Mechanical Blood Pumps for Cardiac Assistance

    Directory of Open Access Journals (Sweden)

    M. Akdis

    2005-01-01

    Full Text Available Cardiac assist devices are classified into the traditional engineering categories of displacement and rotary pumps. Clinical use and indications of the various pump categories are outlined and a detailed description of currently available systems is given. The first part deals with extracorporeal as well as implantable ventricular assist devices (VAD of the displacement type and is followed by a section on current developments in the field of total artificial hearts (TAH. The second part covers the rotary pump category from cardiopulmonary bypass applications to implantable systems, including specific design aspects of radial, diagonal, and axial pumps.

  17. Design and Simulation of Axial Flow Maglev Blood Pump

    Directory of Open Access Journals (Sweden)

    Huachun Wu

    2011-03-01

    Full Text Available The axial flow maglev blood pump (AFMBP has become a global research focus and emphasis for artificial ventricular assist device, which has no mechanical contact, mechanical friction, compact structure and light weight, can effectively solve thrombus and hemolysis. Magnetic suspension and impeller is two of the important parts in the axial flow maglev blood pump, and their structure largely determines the blood pump performance. The research adopts electromagnetic and fluid finite element analysis, and puts forward a method to design the magnetic suspension and impeller of axial flow blood pump, which tacks into account the small volume of axial blood pump. The magnetic bearing’s characteristics are evaluated by electromagnetic finite element analysis. The Blades have been designed by calculating aerofoil bone line, and make simulation analysis for different thicken ways of blade by Fluent software, and make a conclusion that the blade thickened with certain rules has better characteristics in the same conditions. The results will provide some guidance for design of axial flow maglev blood pump, and establish theoretical basis for application of the implantable artificial heart pump.

  18. In vivo evaluation of centrifugal blood pump for cardiopulmonary bypass-Spiral Pump.

    Science.gov (United States)

    da Silva, Cibele; da Silva, Bruno Utiyama; Leme, Juliana; Uebelhart, Beatriz; Dinkhuysen, Jarbas; Biscegli, José F; Andrade, Aron; Zavaglia, Cecília

    2013-11-01

    The Spiral Pump (SP), a centrifugal blood pump for cardiopulmonary bypass (CPB), has been developed at the Dante Pazzanese Institute of Cardiology/Adib Jatene Foundation laboratories, with support from Sintegra Company (Pompeia, Brazil). The SP is a disposable pump with an internal rotor-a conically shaped fuse with double entrance threads. This rotor is supported by two ball bearings, attached to a stainless steel shaft fixed to the housing base. Worm gears provide axial motion to the blood column, and the rotational motion of the conically shaped impeller generates a centrifugal pumping effect, improving pump efficiency without increasing hemolysis. In vitro tests were performed to evaluate the SP's hydrodynamic performance, and in vivo experiments were performed to evaluate hemodynamic impact during usual CPB. A commercially available centrifugal blood pump was used as reference. In vivo experiments were conducted in six male pigs weighing between 60 and 90 kg, placed on CPB for 6 h each. Blood samples were collected just before CPB (T0) and after every hour of CPB (T1-T6) for hemolysis determination and laboratory tests (hematological and biochemical). Values of blood pressure, mean flow, pump rotational speed, and corporeal temperature were recorded. Also, ergonomic conditions were recorded: presence of noise, difficulty in removing air bubbles, trouble in installing the pump in the drive module (console), and difficulties in mounting the CPB circuit. Comparing the laboratory and hemolysis results for the SP with those of the reference pump, we can conclude that there is no significant difference between the two devices. In addition, reports made by medical staff and perfusionists described a close similarity between the two devices. During in vivo experiments, the SP maintained blood flow and pressure at physiological levels, consistent with those applied in cardiac surgery with CPB, without presenting any malfunction. Also, the SP needed lower rotational

  19. Small bowel enteroclysis using a hemodialysis blood pump

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soon Jin; Lim, Hyo Keun; Lee, Won Jae; Kim, Kyeong Ah; Lee, Yeon Ok; Hwang, Jung Hwa; Choi, Sang Hee; Lim, Jae Hoon [Samsung Medical Center, Seoul (Korea, Republic of)

    1998-04-01

    The purpose of this study is to describe the usefulness of small bowel enteroclysis using a hemodialysis blood pump. Over 1 16 month period, 135 double contrast small bowel enteroclysis examinations were performed in 132 patients using a hemodialysis blood pump. Following incubation of the proximal jejunum, barium at a dilution of 50 % and 0.5 %-methylcellulose were infused at a constant rate using a hemodialysis blood pump and multiple spot films of the small intestine were obtained. Success rate, quality of radiographs, positive findings, fluoroscopic time and complications were evaluated. It spite of the long fluoroscopic time and invasiveness, double contrast small bowel enteroclysis is useful for the evaluation of small bowel disease. The infusion of barium and methylcellulose using a hemodialysis blood pump give radiographs of good quality. (author). 18 refs., 2 tabs., 10 figs.

  20. Absence of peripheral blood mononuclear cells priming in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Santos B.C.

    2003-01-01

    Full Text Available As a consequence of the proinflammatory environment occurring in dialytic patients, cytokine overproduction has been implicated in hemodialysis co-morbidity. However, there are discrepancies among the various studies that have analyzed TNF-alpha synthesis and the presence of peripheral blood mononuclear cell (PBMC priming in this clinical setting. We measured bioactive cytokine by the L929 cell bioassay, and evaluated PBMC TNF-alpha production by 32 hemodialysis patients (HP and 51 controls. No difference in TNF-alpha secretion was observed between controls and HP (859 ± 141 vs 697 ± 130 U/10(6 cells. Lipopolysaccharide (5 µg/ml did not induce any further TNF-alpha release, showing no PBMC priming. Paraformaldehyde-fixed HP PBMC were not cytotoxic to L929 cells, suggesting the absence of membrane-anchored TNF-alpha. Cycloheximide inhibited PBMC cytotoxicity in HP and controls, indicating lack of a PBMC TNF-alpha pool, and dependence on de novo cytokine synthesis. Actinomycin D reduced TNF-alpha production in HP, but had no effect on controls. Therefore, our data imply that TNF-alpha production is an intrinsic activity of normal PBMC and is not altered in HP. Moreover, TNF-alpha is a product of de novo synthesis by PBMC and is not constitutively expressed on HP cell membranes. The effect of actinomycin D suggests a putative tighter control of TNF-alpha mRNA turnover in HP. This increased dependence on TNF-alpha RNA transcription in HP may reflect an adaptive response to hemodialysis stimuli.

  1. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.

    Science.gov (United States)

    Schüle, Chan Yong; Thamsen, Bente; Blümel, Bastian; Lommel, Michael; Karakaya, Tamer; Paschereit, Christian Oliver; Affeld, Klaus; Kertzscher, Ulrich

    2016-04-18

    Left ventricular assist devices (LVADs) have become a standard therapy for patients with severe heart failure. As low blood trauma in LVADs is important for a good clinical outcome, the assessment of the fluid loads inside the pump is critical. More specifically, the flow features on the surfaces where the interaction between blood and artificial material happens is of great importance. Therefore, experimental data for the near-wall flows in an axial rotary blood pump were collected and directly compared to computational fluid dynamic results. For this, the flow fields based on unsteady Reynolds-averaged Navier-Stokes simulations-computational fluid dynamics (URANS-CFD) of an axial rotary blood pump were calculated and compared with experimental flow data at one typical state of operation in an enlarged model of the pump. The focus was set on the assessment of wall shear stresses (WSS) at the housing wall and rotor gap region by means of the wall-particle image velocimetry technique, and the visualization of near-wall flow structures on the inner pump surfaces by a paint erosion method. Additionally, maximum WSS and tip leakage volume flows were measured for 13 different states of operation. Good agreement between CFD and experimental data was found, which includes the location, magnitude, and direction of the maximum and minimum WSS and the presence of recirculation zones on the pump stators. The maximum WSS increased linearly with pressure head. They occurred at the upstream third of the impeller blades and exceeded the critical values with respect to hemolysis. Regions of very high shear stresses and recirculation zones could be identified and were in good agreement with simulations. URANS-CFD, which is often used for pump performance and blood damage prediction, seems to be, therefore, a valid tool for the assessment of flow fields in axial rotary blood pumps. The magnitude of maximum WSS could be confirmed and were in the order of several hundred Pascal.

  2. A novel, minimally invasive rat model of normothermic cardiopulmonary bypass model without blood priming

    Institute of Scientific and Technical Information of China (English)

    Zhu Yaobin; Liu Donghai; Li Xiaofeng; Liu Aijun; Wang Qiang; Qiao Chenhui; Zhang Jing

    2014-01-01

    Background Cardiopulmonary bypass (CPB) has been shown to be associated with systemic inflammatory response leading to postoperative organ dysfunction.Elucidating the underlying mechanisms and developing protective strategies for the pathophysiological consequences of CPB have been hampered due to the absence of a satisfactory recovery animal model.The purpose of this study was to establish a novel,minimally invasive rat model of normothermic CPB model without blood priming.Methods Twenty adult male Sprague-Dawley rats weighing 450-560 g were randomly divided into CPB group (n=10) and control group (n=10).All rats were anaesthetized and mechanically ventilated.The carotid artery and jugular vein were cannulated.The blood was drained from the right atrium via the right jugular and further transferred by a miniaturized roller pump to a hollow fiber oxygenator and back to the rat via the left carotid artery.The volume of the priming solution,composed of 6% HES130/0.4 and 125 IU heparin,was less than 12 ml.The surface of the hollow fiber oxygenator was 0.075 m2.CPB was conducted for 60 minutes at a flow rat of 100-120 ml· kg-1· min-1 in CPB group.Oxygen flow/perfusion flow was 0.8 to 1.0,and the mean arterial pressure remained 60-80 mmHg.Results All CPB processes were successfully achieved.Blood gas analysis and hemodynamic parameters of each time point were in accordance with normal ranges.The vital signs of all rats were stable.Conclusions The establishment of CPB without blood priming in rats can be achieved successfully.The nontransthoracic model should facilitate the investigation of pathophysiological processes concerning CPB-related multiple organ dysfunction and possible protective interventions.This novel,recovery,and reproducible minimally invasive CPB model may open the field for various studies on the pathophysiological process of CPB and systemic ischemia-reperfusion injury in vivo.

  3. Classification of Implantable Rotary Blood Pump States With Class Noise.

    Science.gov (United States)

    Ooi, Hui-Lee; Seera, Manjeevan; Ng, Siew-Cheok; Lim, Chee Peng; Loo, Chu Kiong; Lovell, Nigel H; Redmond, Stephen J; Lim, Einly

    2016-05-01

    A medical case study related to implantable rotary blood pumps is examined. Five classifiers and two ensemble classifiers are applied to process the signals collected from the pumps for the identification of the aortic valve nonopening pump state. In addition to the noise-free datasets, up to 40% class noise has been added to the signals to evaluate the classification performance when mislabeling is present in the classifier training set. In order to ensure a reliable diagnostic model for the identification of the pump states, classifications performed with and without class noise are evaluated. The multilayer perceptron emerged as the best performing classifier for pump state detection due to its high accuracy as well as robustness against class noise.

  4. Classification of physiologically significant pumping states in an implantable rotary blood pump: patient trial results.

    Science.gov (United States)

    Karantonis, Dean M; Mason, David G; Salamonsen, Robert F; Ayre, Peter J; Cloherty, Shaun L; Lovell, Nigel H

    2007-01-01

    An integral component in the development of a control strategy for implantable rotary blood pumps is the task of reliably detecting the occurrence of left ventricular collapse due to overpumping of the native heart. Using the noninvasive pump feedback signal of impeller speed, an approach to distinguish between overpumping (or ventricular collapse) and the normal pumping state has been developed. Noninvasive pump signals from 10 human pump recipients were collected, and the pumping state was categorized as either normal or suction, based on expert opinion aided by transesophageal echocardiographic images. A number of indices derived from the pump speed waveform were incorporated into a classification and regression tree model, which acted as the pumping state classifier. When validating the model on 12,990 segments of unseen data, this methodology yielded a peak sensitivity/specificity for detecting suction of 99.11%/98.76%. After performing a 10-fold cross-validation on all of the available data, a minimum estimated error of 0.53% was achieved. The results presented suggest that techniques for pumping state detection, previously investigated in preliminary in vivo studies, are applicable and sufficient for use in the clinical environment.

  5. Condition monitoring of rotary blood pumps.

    Science.gov (United States)

    Jammu, V B; Malanoski, S; Walter, T; Smith, W

    1997-01-01

    Long-term, trouble-free operation of ventricular assist devices (VADs) is critical to the patient. A catastrophic failure of the VAD could cost the patient's life, thus defeating the purpose of the device. The targeted 90% 5 year reliability also implies that the average device life would exceed the 5 year limit. Time based explantation of the device after the fifth year will replace many devices with significant additional life, subject the patient to unnecessary surgical risk, and increase costs. To preclude the need for time based replacements and prevent catastrophic failures, a condition monitor is proposed in this article for early detection of faults in VADs. To develop this monitor, the effectiveness of various sensing and monitoring methods for determining the VAD condition is investigated. A Hemadyne pump was instrumented with a set of eight sensors, and a series of experiments were performed to record and analyze signals from the normal and abnormal pumps with five different faults. Statistical, spectral, envelope, and ensemble averaging analyses were performed to characterize changes in sensor signals due to faults. Experimental results indicate that statistical and frequency information from the acceleration and dynamic pressure signals can clearly detect and identify various VAD faults.

  6. Performance of enlarged blood pump models with five different impellers.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In earlier studies, a 5:1 enlarged pump model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump had been constructed and the flow characteristics investigated. Although the results obtained were satisfactory, the medium used was air. A 5:1 enlarged pump model using water as the medium thus was designed and constructed. Five different impeller blade profile designs were used in the present study. By varying (1) the blade profile design: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed, the flow characteristics of the pump were investigated. It was found that the impeller with the higher number of blades, used in the forward and straight blade profiles, have the best performance.

  7. Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure.

    Science.gov (United States)

    Kawahito, Koji

    2013-09-01

    Although non-destructive and continuous monitoring is indispensable for long-term circulatory support with rotary blood pumps, a practical monitoring system has not yet been developed. The objective of this study was to investigate the possibility of detecting pump failure caused by thrombus formation through the monitoring of vibration signals. The data acquisition equipment included vibration pickups, a charge amplifier, vibration analysis systems, and exclusive hardware. A pivot-bearing centrifugal pump with a mock circuit was investigated for vibration analysis. To simulate the four common areas of thrombus formation, we used a piece of silicon attached to each of the following four locations: the total area of the bottom of the impeller, an eccentric shape on the bottom of the impeller, a circular shape around the shaft top, and an eccentric shape on the top of the impeller. Vibration signals were picked up, and the power spectrum density analysis was performed at pump rotational speeds of 2100, 2400, and 3000 rpm. In this study, pump failure could be detected, and the types of imitation thrombi could be determined. We conclude that vibration detection with a computerized analysis system is a potentially valuable diagnostic tool for long-term circulatory support with rotary blood pumps.

  8. Dynamic characteristics and mechatronics model for maglev blood pump

    Science.gov (United States)

    Sun, Kun; Chen, Chen

    2017-01-01

    Magnetic bearing system(MBs) has been developed in the new-generation blood pump due to its low power consumption, low blood trauma and high durability. However, MBs for a blood pump were almost influenced by a series of factors such as hemodynamics, rotation speeds and actuator response in working fluids, compared with those applied in other industrial fields. In this study, the dynamic characteristics of MBs in fluid environments, including the influence of the pumping fluid and rotation of the impeller on the radial dynamic model were investigated by measuring the frequency response to sinusoidal excitation upon coils, and the response of radial displacement during a raise in the speed. The excitation tests were conducted under conditions in which the blood pump was levitated in air and water and with or without rotation. The experimental and simulated results indicate that rotations of the impeller affected the characteristics of MBs in water apparently, and the vibration in water was decreased, compared with that in air due to the hydraulic force. During the start-up and rotation, the actuator failed to operate fully and timely, and the voltage supplied can be chosen under the consideration of the rotor displacement and consumption.

  9. Computational fluid dynamics analysis of the pediatric tiny centrifugal blood pump (TinyPump).

    Science.gov (United States)

    Kido, Kazuyuki; Hoshi, Hideo; Watanabe, Nobuo; Kataoka, Hiroyuki; Ohuchi, Katsuhiro; Asama, Junichi; Shinshi, Tadahiko; Yoshikawa, Masaharu; Takatani, Setsuo

    2006-05-01

    We have developed a tiny rotary centrifugal blood pump for the purpose of supporting circulation of children and infants. The pump is designed to provide a flow of 0.1-4.0 L/min against a head pressure of 50-120 mm Hg. The diameter of the impeller is 30 mm with six straight vanes. The impeller is supported by a hydrodynamic bearing at its center and rotated with a radial coupled magnetic driver. The bearing that supports rotation of the impeller of the tiny centrifugal blood pump is very critical to achieve durability, and clot-free and antihemolytic performance. In this study, computational fluid dynamics (CFD) analysis was performed to quantify the secondary flow through the hydrodynamic bearing at the center of the impeller and investigated the effects of bearing clearance on shear stress to optimize hemolytic performance of the pump. Two types of bearing clearance (0.1 and 0.2 mm) were studied. The wall shear stress of the 0.1-mm bearing clearance was lower than that of 0.2-mm bearing clearance at 2 L/min and 3000 rpm. This was because the axial component of the shear rate significantly decreased due to the narrower clearance even though the circumferential component of the shear rate increased. Hemolysis tests showed that the normalized index of hemolysis was reduced to 0.0076 g/100 L when the bearing clearance was reduced to 0.1 mm. It was found that the CFD prediction supported the experimental trend. The CFD is a useful tool for optimization of the hydrodynamic bearing design of the centrifugal rotary blood pump to optimize the performance of the pump in terms of mechanical effect on blood cell elements, durability of the bearing, and antithrombogenic performance.

  10. Identification and classification of physiologically significant pumping states in an implantable rotary blood pump.

    Science.gov (United States)

    Karantonis, Dean M; Lovell, Nigel H; Ayre, Peter J; Mason, David G; Cloherty, Shaun L

    2006-09-01

    In a clinical setting it is necessary to control the speed of rotary blood pumps used as left ventricular assist devices to prevent possible severe complications associated with over- or underpumping. The hypothesis is that by using only the noninvasive measure of instantaneous pump impeller speed to assess flow dynamics, it is possible to detect physiologically significant pumping states (without the need for additional implantable sensors). By varying pump speed in an animal model, five such states were identified: regurgitant pump flow, ventricular ejection (VE), nonopening of the aortic valve over the cardiac cycle (ANO), and partial collapse (intermittent and continuous) of the ventricle wall (PVC-I and PVC-C). These states are described in detail and a strategy for their noninvasive detection has been developed and validated using (n = 6) ex vivo porcine experiments. Employing a classification and regression tree, the strategy was able to detect pumping states with a high degree of sensitivity and specificity: state VE-99.2/100.0% (sensitivity/specificity); state ANO-100.0/100.0%; state PVC-I- 95.7/91.2%; state PVC-C-69.7/98.7%. With a simplified binary scheme differentiating suction (PVC-I, PVC-C) and nonsuction (VE, ANO) states, both such states were detected with 100% sensitivity.

  11. A new design and computational fluid dynamics study of an implantable axial blood pump.

    Science.gov (United States)

    Koochaki, Mojtaba; Niroomand-Oscuii, Hanieh

    2013-12-01

    Considering small thoracic space, using implantable ventricular assist device requires reduction in a pump size. Among many available blood pumps, axial blood pumps have attracted greatly because of their small size. In this article, a new miniature axial blood pump has been designed and studied which can be easily implanted in the human body. In this design, the pump overall length decreased by a little increasing in the pump diameter, and new blade geometry is used to produce a streamlined, idealized, and nonobstructing blood flow path in the pump. By means of computational fluid dynamic, the flow pattern through the pump has been predicted and overall pump performance and efficiency has been computed. Also, to ensure a reliable VAD design, two methods for checking wall shear stress were used to confirm that this pump wouldn't cause serious blood damage.

  12. CFD Application in Implantable Rotary Blood Pump Design and Validation

    Institute of Scientific and Technical Information of China (English)

    YI Qian

    2004-01-01

    Implantable rotary blood pump (IRBP) has been promoted to the stage of clinical trial. This paper introduces a unique IRBP without a shaft. Instead of using thrombogenic pivots or power-drawing magnetic suspension, impeller is supported hydrodynamically when rotating, by lubrication flows in the thin spaces between itself and the pump body. To this end, the flow is very difficult to be measured using usual laboratory equipments. Therefore, computational fluid dynamics (CFD) has been applied as an important tool in the IRBP design and its validation procedure. Several CFD results such as pump performance improvement, unsteady hydraulic dynamic analysis, biocapability prediction, validation and verification (V&V), and flow visualization have been performed.

  13. CFD Application in Implantable Rotary Blood Pump Design and Validation

    Institute of Scientific and Technical Information of China (English)

    YIQian

    2004-01-01

    Implantable rotary blood pump (IRBP) has been promoted to the stage of clinical trial. This paper introduces a unique IRBP without a.shaft. Instead of using thrombogenic pivots or power-drawing magnetic suspension, impeller is supported hydrodynamically when rotating, by lubrication flows in the thin spaces between itself and the pump body. To this end, the flow is very difficult to be measured using usual laboratory equipments. Therefore, computational fluid dynamics (CFD) has been applied as an important tool in the IRBP design and its validation procedure. Several CFD results such as pump performance improvement, unsteady hydraulic dynamic analysis, biocapability prediction, validation and verification (V&V), and flow visualization have been performed.

  14. The Aachen MiniHLM--a miniaturized heart-lung machine for neonates with an integrated rotary blood pump.

    Science.gov (United States)

    Arens, Jutta; Schnoering, Heike; Pfennig, Michael; Mager, Ilona; Vázquez-Jiménez, Jaime F; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2010-09-01

    The operation of congenital heart defects in neonates often requires the use of heart-lung machines (HLMs) to provide perfusion and oxygenation. This is prevalently followed by serious complications inter alia caused by hemodilution and extrinsic blood contact surfaces. Thus, one goal of developing a HLM for neonates is the reduction of priming volume and contact surface. The currently available systems offer reasonable priming volumes for oxygenators, reservoirs, etc. However, the necessary tubing system contains the highest volumes within the whole system. This is due to the use of roller pumps; hence, the resulting placement of the complete HLM is between 1 and 2 m away from the operating table due to connective tubing between the components. Therefore, we pursued a novel approach for a miniaturized HLM (MiniHLM) by integrating all major system components in one single device. In particular, the MiniHLM is a HLM with the rotary blood pump centrically integrated into the oxygenator and a heat exchanger integrated into the cardiotomy reservoir which is directly connected to the pump inlet. Thus, tubing is only necessary between the patient and MiniHLM. A total priming volume of 102 mL (including arterial filter and a/v line) could be achieved. To validate the overall concept and the specific design we conducted several in vitro and in vivo test series. All tests confirm the novel concept of the MiniHLM. Its low priming volume and blood contact surface may significantly reduce known complications related to cardiopulmonary bypass in neonates (e.g., inflammatory reaction and capillary leak syndrome). © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Implantable axialflow blood pump for left ventricular support.

    Science.gov (United States)

    Untaroiu, Alexandrina; Wood, Houston G; Allaire, Paul E

    2008-01-01

    Artificial blood pumps, either ventricular assist devices (VADs) or total artificial hearts, are currently employed for bridge to recovery, bridge to transplant, and destination therapy situations. The clinical effectiveness of VADs has been demonstrated; however, all of the currently available pumps have a limited life because of either the damage they cause to blood or their limited mechanical design life. A magnetically suspended rotary blood pump offers the potential to meet the requirements of both extending design life and causing negligible blood damage due to superior hemodynamics. Therefore, over the last few years, efforts of an interdisciplinary research team at University of Virginia have been concentrated on the design and development of a fully implantable axial flow VAD with a magnetically levitated impeller (LEV-VAD). This paper details the second generation developmental prototype (LEV-VAD2 design configuration) and includes a complete CFD analysis of device performance. Based on encouraging results of the first design stage, including a good agreement between the CFD performance estimations and the experimental measurements, a second design phase was initiated in an attempt to enhance device flow performance and suspension system capabilities. Using iterative design optimization stages, the design of the impeller and the geometry of the stationary and rotating blades have been reevaluated. A thorough CFD analysis allowed for optimization of the blood flow path such that an optimal trade-off among the hydraulic performance, specific requirements of a blood pump, and manufacturing requirements has been achieved. Per the CFD results, the LEV-VAD2 produces 6 lpm and 100 mmHg at a rotational speed of 7,000 rpm. The pressure-flow performance predictions indicate the LEV-VAD2's ability to deliver adequate flow over physiologic pressures for rotational speeds varying from 5,000 to 8,000 rpm. The blood damage numerical predictions also demonstrate

  16. [Study on optimal selection of structure of vaneless centrifugal blood pump with constraints on blood perfusion and on blood damage indexes].

    Science.gov (United States)

    Hu, Zhaoyan; Pan, Youlian; Chen, Zhenglong; Zhang, Tianyi; Lu, Lijun

    2012-12-01

    This paper is aimed to study the optimal selection of structure of vaneless centrifugal blood pump. The optimal objective is determined according to requirements of clinical use. Possible schemes are generally worked out based on structural feature of vaneless centrifugal blood pump. The optimal structure is selected from possible schemes with constraints on blood perfusion and blood damage indexes. Using an optimal selection method one can find the optimum structure scheme from possible schemes effectively. The results of numerical simulation of optimal blood pump showed that the method of constraints of blood perfusion and blood damage is competent for the requirements of selection of the optimal blood pumps.

  17. Noninvasive pulsatile flow estimation for an implantable rotary blood pump.

    Science.gov (United States)

    Karantonis, Dean M; Cloherty, Shaun L; Mason, David G; Ayre, Peter J; Lovell, Nigel H

    2007-01-01

    A noninvasive approach to the task of pulsatile flow estimation in an implantable rotary blood pump (iRBP) has been proposed. Employing six fluid solutions representing a range of viscosities equivalent to 20-50% blood hematocrit (HCT), pulsatile flow data was acquired from an in vitro mock circulatory loop. The entire operating range of the pump was examined, including flows from -2 to 12 L/min. Taking the pump feedback signals of speed and power, together with the HCT level, as input parameters, several flow estimate models were developed via system identification methods. Three autoregressive with exogenous input (ARX) model structures were evaluated: structures I and II used the input parameters directly; structure II incorporated additional terms for HCT; and the third structure employed as input a non-pulsatile flow estimate equation. Optimal model orders were determined, and the associated models yielded minimum mean flow errors of 5.49% and 0.258 L/min for structure II, and 5.77% and 0.270 L/min for structure III, when validated on unseen data. The models developed in this study present a practical method of accurately estimating iRBP flow in a pulsatile environment.

  18. The margin of safety in the use of a straight path centrifugal blood pump.

    Science.gov (United States)

    Kijima, T; Nojiri, C; Oshiyama, H; Horiuchi, K; Nogawa, A; Hamasaki, H; Ogihara, M; Katsuda, H S; Amano, N; Fukasawa, H

    1994-09-01

    A new centrifugal blood pump with a rotor that arranges 6 straight paths radially was developed for open heart surgery and temporary circulatory support. We describe comparative studies of the margin of safety in the practical use of the new pump. This pump was evaluated for temperature increase, cavitation, and pressure sensitivity. Two commercially available centrifugal pumps, the Biomedicus cone type and the Sarns 3M impeller type, were used as control pumps. The temperature increase in the new pump was four times slower than in the impeller pump when the outlet and the inlet of the pump was clamped. No sign of cavitation was observed when 0.1 ml air was introduced to the pump inlet under a negative pressure of 200 mm Hg in fresh bovine blood. As for pressure sensitivity of centrifugal pumps in practical applications, circuit resistance was a more essential factor than flow-pressure curves of the pump.

  19. Design of a centrifugal blood pump: Heart Turcica Centrifugal.

    Science.gov (United States)

    Demir, Onur; Biyikli, Emre; Lazoglu, Ismail; Kucukaksu, Suha

    2011-07-01

    A prototype of a new implantable centrifugal blood pump system named Heart Turcica Centrifugal (HTC) was developed as a left ventricular assist device (LVAD) for the treatment of end-stage cardiac failure. In the development of HTC, effects of blade height and volute tongue profiles on the hydraulic and hemolytic performances of the pump were investigated. As a result, the prototype was manufactured using the best blade height and volute tongue profiles. Performance of the prototype model was experimentally evaluated in a closed-loop flow system using water as the medium. The hydraulic performance requirement of an LVAD (5 L/min flow rate against a pressure difference of 100 mm Hg) was attained at 2800 rpm rotational speed.

  20. Unsteady numerical calculation and validation on self-priming process of self-priming spray irrigation pump%自吸喷灌泵自吸过程的非定常流动数值计算与验证

    Institute of Scientific and Technical Information of China (English)

    王川; 施卫东; 李伟; 张德胜; 蒋小平

    2016-01-01

    In order to establish one suitable numerical method of gas-liquid two-phase flow, based on ANSYS CFX software, the numerical calculation on the gas-liquid two-phase flow is conducted to simulate the self-priming process of the self-priming spray irrigation pump. The phenomena of gas-liquid mixing, gas-liquid separation and gas-liquid escape are studied, while the velocity, pressure and gas volume fraction in the pump are analyzed so as to understand the characteristics of gas-liquid two-phase flow. It’s finally found the whole self-priming process is divided into 3 stages: the gas-suction stage due to the impeller’s rotating role in the initial self-priming stage, the gas-suction stage due to the gas-water mixing and the gas-water separation role in the middle self-priming stage, and the gas-suction stage due to that the water flows from the pump import into the pump cavity in the last self-priming stage. Moreover, the self-priming time of the initial and last self-priming stages accounts for a small percentage of the whole self-priming process, but the self-priming speed is rather large. The middle self-priming stage is the main stage in the self-priming process, which determines the length of self-priming time. In the initial self-priming stage, the self-priming pump takes the drainage as the principle thing, and much gas mixing with water goes out together from the pump. With the gas rate of impeller increasing, the drainage ability of self-priming pump weakens gradually, and the gas-suction speed is first quick and then slows. After entering the middle self-priming stage, the large negative pressure exists on the impeller inlet, the water column in the import pipe goes up constantly, and its weight increases gradually, so the gas-suction speed slows with it. In the last self-priming stage, the water in the pump import goes into the impeller, whose power capability is enhanced obviously, and the water mixing with the gas goes to the pump export together, so

  1. Mechanical damage of red blood cells by rotary blood pumps: selective destruction of aged red blood cells and subhemolytic trauma.

    Science.gov (United States)

    Sakota, Daisuke; Sakamoto, Ryuki; Sobajima, Hideo; Yokoyama, Naoyuki; Waguri, Satoshi; Ohuchi, Katsuhiro; Takatani, Setsuo

    2008-10-01

    In this study, mean cell volume (MCV), mean cell hemoglobin concentration (MCHC), and mean cell hemoglobin (MCH) were measured to quantify RBC damage by rotary blood pumps. Six-hour hemolysis tests were conducted with a Bio-pump BPX-80, a Sarns 15200 roller pump, and a prototype mag-lev centrifugal pump (MedTech Heart) using fresh porcine blood circulated at 5 L/min against a 100 mm Hg head pressure. The temperature of the test and noncirculated control blood was maintained at 37 degrees C. The normalized index of hemolysis (NIH) of each pump was determined by measuring the plasma-free hemoglobin level. The MCV was measured with a Coulter counter, and MCHC was derived from total hemoglobin and hematocrit. MCH was derived from MCV and MCHC. A multivariance statistical analysis (ANOVA) revealed statistically significant differences (n = 15, P < 0.05) in MCV, MCHC, and MCH between the blood sheared by the rotary blood pumps and the nonsheared control blood. Normalized to the control blood, the Bio-pump BPX-80 showed an MCV of 1.04 +/- 0.03, an MCHC of 0.95 +/- 0.04, and an MCH of 0.98 +/- 0.02; the mag-lev MedTech Heart had an MCV of 1.02 +/- 0.02, an MCHC of 0.97 +/- 0.02, and an MCH of 0.99 +/- 0.01; and the roller pump exhibited an MCV of 1.03 +/- 0.03, an MCHC of 0.96 +/- 0.03, and an MCH of 0.99 +/- 0.01. Per 0.01 increase in NIH, the BPX-80 showed a normalized MCV change of +10.1% and a normalized MCHC change of -14.0%; the MedTech Heart demonstrated a +6.9% MCV and -9.5% MCHC change; and the roller pump had a +0.5% MCV and -0.6% MCHC change. Due to shear in the pump circuits, the RBC increased while the MCHC decreased. The likely mechanism is that older RBCs with smaller size and higher hemoglobin concentration were destroyed fast by the shear, leaving younger RBCs with larger size and lower hemoglobin concentration. Subhemolytic trauma caused the intracellular hemoglobin to decrease due to gradual hemoglobin leakage through the micropores formed in the thinned

  2. A self-priming microfluidic diaphragm pump capable of recirculation fabricated by combining soft lithography and traditional machining.

    Science.gov (United States)

    Sin, Aaron; Reardon, Christopher F; Shuler, Michael L

    2004-02-05

    Fluid transport is crucial in the development of microanalytical devices. While there are many micropump designs available, most are incapable of sustaining recirculation of fluid at microL/min to mL/min levels. We have designed and fabricated a positive displacement micropump by combining soft lithography with traditional bulk machining. The micropump is actuated through pneumatic pressure. The pump is self-priming and is suitable for recirculating fluid through a microfluidic device containing mammalian cell culture. By custom designing the volume of the pumping chamber, tight control of the output flow rate can be obtained by changing the actuation frequency. It can also be fabricated easily on plastic substrates without access to expensive microfabrication equipment.

  3. Design of a small centrifugal blood pump with magnetic bearings.

    Science.gov (United States)

    Jahanmir, Said; Hunsberger, Andrew Z; Ren, Zhaohui; Heshmat, Hooshang; Heshmat, Crystal; Tomaszewski, Michael J; Walton, James F

    2009-09-01

    Design of a blood pump with a magnetically levitated rotor requires rigorous evaluation of the magnetic bearing and motor requirements and analysis of rotor dynamics and hydraulic performance with attention to hemolysis and thrombosis potential. Given the desired geometric dimensions, the required operating speed, flow in both the main and wash flow regions, and magnetic bearing performance, one of several design approaches was selected for a new prototype. Based on the estimated operating speed and clearance between the rotor and stator, the motor characteristics and dimensions were estimated. The motor stiffness values were calculated and used along with the hydraulic loading due to the fluid motion to determine the best design for the axial and radial magnetic bearings. Radial and axial stability of the left ventricular assist device prototype was verified using finite element rotor dynamic analysis. The analysis indicated that the rotor could be completely levitated and spun to the desired operating speed with low power loss and no mechanical contact. In vitro experiments with a mock loop test setup were performed to evaluate the performance of the new blood pump prototype.

  4. Measurements of enlarged blood pump models using Laser Doppler Anemometer.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In an earlier study (Chua et al., 1998, 1999a), a 5:1 enlarged model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump (Akamatsu et al., 1995) with five different impeller blade profiles was designed and constructed. Their respective flow characteristics with respect to (1) the three different blade profile designs: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed were investigated. Among the five impeller designs, the results obtained suggested that impellers A and C designs should be adopted if higher head is required. Impellers A and C therefore were selected for the flow in between their blades to be measured using Laser Doppler Anemometer (LDA), so as to have a better understanding of the flow physics with respect to the design parameters.

  5. Partial characterization of lipids that develop during the routine storage of blood and prime the neutrophil NADPH oxidase

    Science.gov (United States)

    Silliman, Christopher C.; Clay, Keith L.; Thurman, Gail W.; Johnson, Chris A.; Ambruso, Daniel R.

    2015-01-01

    Factors developed during the routine storage of whole blood and packed red blood cells that primed the neutrophil (PMN) reduced nicotinamide adenine dinucleotide phosphate (NADPH) oxidase significantly by 2 weeks of storage, with maximal priming activity by product outdate (2.5 to 3.7 fold). These agents appeared to be generated by cellular constituents because stored, acellular plasma did not demonstrate PMN priming. The priming activity was soluble in chloroform. Priming of the oxidase by plasma and plasma extracts was inhibited by WEB 2170, a platelet-activating factor (PAF) receptor antagonist. Separation of the chloroform-soluble compounds from plasma by normal phase high-performance liquid chromatography demonstrated two peaks of priming activity at the retention times of neutral lipids and lysophos-phatidylcholines (lyso-PCs) for both whole blood and packed red blood cells, Analysis of the latter peak of PMN priming by fast atom bombardment mass spectroscopy identified several specific lyso-PC species including C16 and C16 lyso-PAF. Further evaluation by gas chromatography/mass spectroscopy demonstrated that three of these species increased dramatically over product storage time, while the other two species increased modestly, and paralleled the Increase in priming activity. Commercially available, purified mixtures of these lyso-PCs primed the PMN oxidase by twofold. When PMNs were incubated with this mixture of lyso-PCs, acetylated analogs of these compounds rapidly accumulated. Thus lipids, including specific lyso-PC species, develop during routine storage of cellular blood components, prime PMNs, and possibly play a role in the severe complications of transfusion therapy. PMID:7964126

  6. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M;

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC...

  7. Haemolysis following rapid experimental red blood cell transfusion--an evaluation of two infusion pumps

    DEFF Research Database (Denmark)

    Hansen, Tom Giedsing; Sprogøe-Jakobsen, U; Pedersen, C M

    1998-01-01

    The vast majority of infusion pumps used for rapid transfusion of large amounts of blood have never been properly examined regarding their influence on the quality of the red blood cells (RBCs) infused. In this study, we evaluated the effect of two different infusion pumps on the degree of RBC de...

  8. Design and test of new self-priming structure for self-priming centrifugal pump%新型自吸离心泵自吸结构设计与试验研究

    Institute of Scientific and Technical Information of China (English)

    武永生; 刘建瑞; 李红; 陈凯; 常浩

    2016-01-01

    For traditional high flow self-priming centrifugal pumps are subject to poor self-priming per-formance and low efficiency , a large flow self-priming centrifugal pump with a new self-priming struc-ture is designed .In the design , a high-pressure jet is involved into the gas exhaust system of the pump, then the structure of jet nozzle is designed carefully and reasonably , and their main dimensions are decided accordingly .Moreover, a check valve is designed as well for the nozzle , and a globe valve with good air tightness is chosen .A new coupling-clutch transmission device is put forward , in which the shafts of the pump and a compressor is connected with a pulley to ensure the compressor to be de -tached quickly after the self-priming completion .A compressor is selected according to the requirement on the exhaust by the pump and relevant national technical standards .Experiments on the self-priming performance of the newly designed self-priming pump are carried out , and the priming times at diffe-rent suction heights are recorded .The experimental results show that the self-priming times are 62, 92, 121 and 173 s, respectively, when the suction heights are 5.3, 6.0, 7.0 and 8.1 m.These self-priming times are less than those specified in relevant national technical standards .Thus, for the pump, its advantage in the self-priming performance is obvious , and the overall efficiency of the pump unit is also improved significantly .%针对传统大流量自吸离心泵自吸性能差、效率低等问题,设计了一种新型自吸结构的大流量自吸离心泵.将高压空气射流应用于泵的排气系统中,合理设计高压射流喷嘴的结构形式,对其主要尺寸进行计算,同时设计出与射流喷嘴配合工作的止回阀,选择气密性良好的球阀.提出新型轴联离合装置,通过皮带轮连接泵轴与空压机主轴,保证自吸完成后空气压缩机迅速脱离工作,并根据泵的排气要求以及国

  9. On the dynamic suction pumping of blood cells in tubular hearts

    CERN Document Server

    Battista, Nicholas A; Miller, Laura A

    2016-01-01

    Around the third week after gestation in embryonic development, the human heart consists only of a valvless tube, unlike a fully developed adult heart, which is multi-chambered. At this stage in development, the heart valves have not formed and so net flow of blood through the heart must be driven by a different mechanism. It is hypothesized that there are two possible mechanisms that drive blood flow at this stage - Liebau pumping (dynamic suction pumping or valveless pumping) and peristaltic pumping. We implement the immersed boundary method with adaptive mesh refinement (IBAMR) to numerically study the effect of hematocrit on the circulation around a valveless. Both peristalsis and dynamic suction pumping are considered. In the case of dynamic suction pumping, the heart and circulatory system is simplified as a flexible tube attached to a relatively rigid racetrack. For some Womersley number (Wo) regimes, there is significant net flow around the racetrack. We find that the addition of flexible blood cells ...

  10. Evaluation of suction detection during different pumping states in an implantable rotary blood pump.

    Science.gov (United States)

    Ng, Siew-Cheok; Lim, Einly; Mason, David G; Avolio, Alberto P; Lovell, Nigel H

    2013-08-01

    In recent times, the problem of noninvasive suction detection for implantable rotary blood pumps has attracted substantial research interest. Here, we compare the performance of various suction indices for different types of suction and non-suction events based on pump speed irregularity. A total of 171 different indices that consist of previously proposed as well as newly introduced suction indices are tested using regularized logistic regression. These indices can be classified as amplitude based (derived from the mean, maximum, and minimum values of a cycle), duration based (derived from the duration of a cycle), gradient based (derived from the first order as well as higher order differences) and frequency based (derived from the power spectral density). The non-suction event data consists of ventricular ejection with or without arrhythmia and intermittent and continuous non-opening of the aortic valve. The suction event data consists of partial ventricular collapse that occurs intermittently as well as continuously with or without arrhythmia. In addition, we also attempted to minimize the usage of multiple indices by applying the sequential forward floating selection method to find which combination of indices gives the best performance. In general, the amplitude-based and gradient-based indices performed quite well while the duration-based and frequency-based indices performed poorly. By having only two indices ([i] the maximum gradient change in positive slope; and [ii] the standard deviation of the maximum value in a cycle), we were able to achieve a sensitivity of 98.9% and a specificity of 99.7%.

  11. [Research on flow characteristics in a non-blade centrifugal blood pump based on CFD technology].

    Science.gov (United States)

    Cheng, Yunzhang; Luo, Binhai; Wu, Wenquan; Jiang, Lei

    2010-10-01

    The problem of thrombus and hemolysis in blood pump has always been an important topic to study in the development of the blood pump. Numbers of research results show that it is the complicated flow and the high shear stress of the mechanical movement that result in the thrombus and hemolysis. In this study, with the cooperation of Shanghai Children's Medical Center, we have used computational fluid dynamics (CFD) commercial software FLUENT to compute and analyze the flow characteristics in a non-blade centrifugal blood pump. The results figure out that this pump has a reasonable flow distribution and the shear stress distribution is under the critical broken state of red blood cell; meanwhile, there is less thrombus and hemolysis in this pump. So it is in the foreground for clinical use.

  12. Hydraulic refinement of an intraarterial microaxial blood pump.

    Science.gov (United States)

    Siess, T; Reul, H; Rau, G

    1995-05-01

    Intravascularly operating microaxial pumps have been introduced clinically proving to be useful tools for cardiac assist. However, a number of complications have been reported in literature associated with the extra-corporeal motor and the flexible drive shaft cable. In this paper, a new pump concept is presented which has been mechanically and hydraulically refined during the developing process. The drive shaft cable has been replaced by a proximally integrated micro electric motor and an extra-corporeal power supply. The conduit between pump and power supply consists of only an electrical power cable within the catheter resulting in a device which is indifferent to kinking and small curvature radii. Anticipated insertion difficulties, as a result of a large outer pump diameter, led to a two-step approach with an initial 6,4mm pump version and a secondary 5,4mm version. Both pumps meet the hydraulic requirement of at least 2.5l/min at a differential pressure of 80-100 mmHg. The hydraulic refinements necessary to achieve the anticipated goal are based on ongoing hydrodynamic studies of the flow inside the pumps. Flow visualization on a 10:1 scale model as well as on 1:1 scale pumps have yielded significant improvements in the overall hydraulic performance of the pumps. One example of this iterative developing process by means of geometrical changes on the basis of flow visualization is illustrated for the 6.4mm pump.

  13. A novel rat model of cardiopulmonary bypass for deep hypothermic circulatory arrest without blood priming

    Institute of Scientific and Technical Information of China (English)

    Zhang Weihua; Zhang Yanbo; Liu Donghai; Zhu Yaobin; Qiao Chenhui; Wang Jiaxiang; Xu Yulin

    2014-01-01

    Background Large animal cardiopulmonary bypass (CPB) models are expensive,and prevent assessment of neurocognitive function,and difficulties with long-term recovery.The purpose of this study was to establish a novel rat model of cardiopulmonary bypass for deep hypothermic circulatory arrest without blood priming.Methods Twenty adult male Sprague-Dawley rats weighing 450-560 g were randomized to CPB with deep hypothermic circulatory arrest (DHCA) and control groups,with 10 rats each.The experimental protocols,including blood and crystalloid fluid administration,anesthesia,orotracheal intubation,ventilation,cannulation,and heparinization were identical in both groups.After inducing cardiac arrest,the circuit was turned off and rats were left in a DHCA state for 15 minutes.Rats were rewarmed to 34℃ to 35℃ over a period of 36 to 42 minutes using CPB-assisted rewarming,a heating blanket,and a heating lamp along with administration of 0.1 mEq of sodium bicarbonate and 0.14 mEq of calcium chloride.The remaining priming volume was reinfused and animals were weaned from CPB.Results All CPB with DHCA processes were successfully achieved.Blood gas analysis and hemodynamic parameters were in the normal range.The vital signs of all rats were stable.Conclusions Our CPB circuit has several novel features,including a small priming volume,active cooling/rewarming processes,vacuum-assisted venous drainage,peripheral cannulation without thoracotomy or stemotomy,and an accurate means of monitoring peripheral tissue oxygenation.

  14. Estimating mechanical blood trauma in a centrifugal blood pump: laser Doppler anemometer measurements of the mean velocity field.

    Science.gov (United States)

    Pinotti, M; Paone, N

    1996-06-01

    A laser Doppler anemometer (LDA) was used to obtain the mean velocity and the Reynolds stress fields in the inner channels of a well-known centrifugal vaneless pump (Bio-pump). Effects of the excessive flow resistance against which an occlusive pump operates in some surgical situations, such as cardiopulmonary bypass, are illustrated. The velocity vector field obtained from LDA measurements reveals that the constraint-forced vortex provides pumping action in a restricted area in the core of the pump. In such situations, recirculating zones dominate the flow and consequently increase the damage to blood cells and raise the risk of thrombus formation in the device. Reynolds normal and shear stress fields were obtained in the entry flow for the channel formed by two rotating cones to illustrate the effects of flow disturbances on the potential for blood cell damage.

  15. [Numerical assessment of impeller features of centrifugal blood pump based on fast hemolysis approximation model].

    Science.gov (United States)

    Shou, Chen; Guo, Yongjun; Su, Lei; Li, Yongqian

    2014-12-01

    The impeller profile, which is one of the most important factors, determines the creation of shear stress which leads to blood hemolysis in the internal flow of centrifugal blood pump. The investigation of the internal flow field in centrifugal blood pump and the estimation of the hemolysis within different impeller profiles will provide information to improve the performance of centrifugal blood pump. The SST kappa-omega with low Reynolds correction was used in our laboratory to study the internal flow fields for four kinds of impellers of centrifugal blood pump. The flow fields included distributions of pressure field, velocity field and shear stress field. In addition, a fast numerical hemolysis approximation was adopted to calculate the normalized index of hemolysis (NIH). The results indicated that the pressure field distribution in all kinds of blood pump were reasonable, but for the log spiral impeller pump, the vortex and backflow were much lower than those of the other pumps, and the high shear stress zone was just about 0.004%, and the NIH was 0.0089.

  16. Concept designs of nonrotating-type centrifugal blood pump and basic study on output characteristics of the oscillating disk-type centrifugal pump.

    Science.gov (United States)

    Kabei, N; Tuichiya, K; Sakurai, Y

    1994-09-01

    When designing a turbo-type blood pump as an artificial heart, the gap between a rotating shaft and a pump housing should be perfectly sealed to prevent any leakage or contamination through a seal. In addition, blood coagulation in a blood chamber must be avoided. To overcome these problems, we proposed five different nonrotating-type turbo pumps: a caudal-fin-type axial-flow pump, a caudal-fin-type centrifugal pump, a nutating-column-type centrifugal pump, a nutating-collapsible-tube-type centrifugal pump, and an oscillating-disk-type centrifugal pump. We selected and developed the oscillating-disk-type centrifugal pump that consists of a disk, a driving rod, a seal, an oscillation mechanism, and a pump housing. The disk is mounted on the end of the rod, which is connected to a high-speed DC motor through an oscillation mechanism. The rod and the disk do not rotate, but they oscillate in the pump housing. This movement of the disk generates forward fluid flow around the axis (i.e., the rotational fluid flow). Centrifugal force due to fluid rotation supports the pressure difference between the outlet and the inlet. The diameter of the disk is 39 mm, the maximum inner diameter of the pump housing is 40 mm, and the volume of the blood chamber for 25 degrees' oscillation is 16.9 ml. The performance of the pump was tested in a mock circulatory system.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Direct detection of red blood cell fragments: a new flow cytometric method to evaluate hemolysis in blood pumps.

    Science.gov (United States)

    Linneweber, J; Chow, T W; Takano, T; Maeda, T; Nonaka, K; Schulte-Eistrup, S; Kawahito, S; Elert, O; Moake, J L; Nosé, Y

    2001-01-01

    Pump induced hemolysis is presently evaluated by measuring plasma free hemoglobin (fHb). However, this method has disadvantages because quantification of fHb depends on hematocrit (HCT) and hemoglobin (Hb) levels. The aim of this work was to devise a hemoglobin independent method, capable of quantifying cell trauma directly by measuring the number of red blood cell (RBC) fragments. Whole blood flow cytometry was used to quantify circulating RBC fragments derived from a roller pump (Sarns, Inc. Model 2 M 6,002) and a centrifugal pump (Gyro C1E3, Kyocera Corp.). The pumps were tested in a mock circuit for 2 hr (5 L/min flow against 100 mm Hg pressure head). Red blood cell fragments were quantified by a phycoerythrin (PE) labeled glycophorin A antibody specific for erythrocytes. Red blood cell fragments were smaller than the intact RBC population and overlapped in size with the platelet population (based on forward- and side-light scattering measurements). For the roller pump, the values for RBC fragments increased from 1,090 +/- 260/microl at 0 min to 14,880 +/- 5,900/microl after 120 min. In contrast, using the centrifugal pump, there was little increase in RBC fragments (from 730 +/- 270/microl at 0 min to 1,400 +/- 840/microl after 120 min). Flow cytometry can be used for the rapid, sensitive, hemoglobin independent evaluation of pump induced RBC trauma.

  18. Computational Fluid Dynamics-Based Design Optimization Method for Archimedes Screw Blood Pumps.

    Science.gov (United States)

    Yu, Hai; Janiga, Gábor; Thévenin, Dominique

    2016-04-01

    An optimization method suitable for improving the performance of Archimedes screw axial rotary blood pumps is described in the present article. In order to achieve a more robust design and to save computational resources, this method combines the advantages of the established pump design theory with modern computer-aided, computational fluid dynamics (CFD)-based design optimization (CFD-O) relying on evolutionary algorithms and computational fluid dynamics. The main purposes of this project are to: (i) integrate pump design theory within the already existing CFD-based optimization; (ii) demonstrate that the resulting procedure is suitable for optimizing an Archimedes screw blood pump in terms of efficiency. Results obtained in this study demonstrate that the developed tool is able to meet both objectives. Finally, the resulting level of hemolysis can be numerically assessed for the optimal design, as hemolysis is an issue of overwhelming importance for blood pumps.

  19. [Controlling of artificial blood pumps after total heart replacement - an example of disregulation (author's transl)].

    Science.gov (United States)

    Hennig, E; Affeld, K; Kless, H; Mohnhaupt, A; Mohhaupt, R; Clevert, D; Keibach, H; Krautzberger, W; Kleine, H O; Weidemann, H; Bücherl, E S

    1976-12-01

    This is a report on the special regulation problem of the left blood pump after replacement of the natural heart by incorporated extracorporally driven blood pumps in an animal experiment. The consequence of the peripheral self-regulation on the transporting capacity of the bloodpumps considering the driving pressure and the systemic pressure losses has been investigated. Two possible controlling principles and the respective fields of application are discussed on the example of a lung oedema.

  20. Computational fluid dynamics of gap flow in a biocentrifugal blood pump.

    Science.gov (United States)

    Chua, Leok Poh; Song, Guoliang; Yu, Simon Ching Man; Lim, Tau Meng

    2005-08-01

    The centrifugal blood pump with a magnetically suspended impeller has shown its superiority as compared to other artificial heart pumps. However, there is still insufficient understanding of fluid mechanics related issues in the clearance gap. The design nature of the pump requires sufficient washout in the clearance between the impeller and the stationary pump housing inner surface. In this study, numerical simulations were carried out to investigate the flow fields in the gap of the Kyoto-NTN centrifugal blood pump. The flow patterns in the gap region of the blood pump were presented and regions of high and low velocity were identified. It was found that the radial velocity of the blood in the gap was closely related to the pressure distribution at the exit of the impeller, both the highest pressure gradient and the highest radial velocity in the gap occurred at an angular position of 170 degrees . The mass flow rate in the gap was estimated to be 25.2% of the pump outflow, which is close to the measurement results of a five times enlarged test pump. The wall shear stresses on the gap surface were found to be over 21 Pa and below 300 Pa, which is correspondingly higher than the threshold of thrombi formation and is lower than the shearing threshold of red blood cells. Comparison of the 1 : 1 simulation model with the measurement results on a five times enlarged test pump indicates that there are some differences in the resulting radial velocity distributions in the gap and thus the washout mechanism. Two symmetrical high washout regions at both the cutwater and splitter plate were observed in the simulation instead of a single washout region at the splitter plate found in the experimental study. This may be due to the scaling effect of the enlarged test pump; also the medium used in the experiment is different from the simulation.

  1. Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump.

    Science.gov (United States)

    Chung, Michael K H; Zhang, Nong; Tansley, Geoff D; Qian, Yi

    2004-12-01

    The VentrAssist implantable rotary blood pump, intended for long-term ventricular assist, is under development and is currently being tested for its rotor-dynamic stability. The pump consists of a shaftless impeller, which also acts as the rotor of the brushless DC motor. The impeller remains passively suspended in the pump cavity by hydrodynamic forces, which result from the small clearances between the outside surfaces of the impeller and the pump cavity. These small clearances range from approximately 50 microm to 230 microm in size in the version of pump reported here. This article presents experimental investigation into the dynamic characteristics of the impeller-bearing-pump housing system of the rotary blood pump for increasing pump speeds at different flow rates. The pump was mounted on a suspension system consisting of a platform and springs, where the natural frequency and damping ratio for the suspension system were determined. Real-time measurements of the impeller's displacement were performed using Hall effect sensors. A vertical disturbance force was exerted onto the pump housing, causing the impeller to be displaced in vertical direction from its dynamic equilibrium position within the pump cavity. The impeller displacement was represented by a decaying sine wave, which indicated the impeller restoring to its equilibrium position. From the decaying sine wave the natural frequency and stiffness coefficient of the system were determined. Furthermore, the logarithmic decrement method was used to determine the damping ratio and eventually the damping coefficient of the system. Results indicate that stiffness and damping coefficients increased as flow rate and pump speed increased, representing an increase in stability with these changing conditions. However, pump speed had a greater influence on the stiffness and damping coefficients than flow rate did, which was evident through dynamic analysis. Overall the experimental method presented in this

  2. Noninvasive deadbeat control of an implantable rotary blood pump: a simulation study.

    Science.gov (United States)

    Lim, E; Alomari, A H; Savkin, A V; Lovell, N H

    2009-01-01

    A deadbeat controller has been proposed for the control of pulsatile pump flow in an implantable rotary blood pump (IRBP). A lumped parameter model of the cardiovascular system, in combination with the stable dynamical models of pulsatile flow and differential pressure (head) estimation for the IRBP was used to evaluate the controller. Pump speed and current were used as the only measured variables of the control system. The control algorithm was tested using both constant and sinusoidal reference pump flow input, under healthy and heart failure conditions. Results showed that the controller is able to track the reference input with minimal error in the presence of model uncertainty.

  3. Circular pump support of blood circulation in the human body

    Science.gov (United States)

    Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.

    2016-10-01

    The need of circulatory support systems in the treatment of chronic heart failure is increasing constantly, as 20% of patients in the waiting list die every year. Despite the great need for mechanical heart support systems, using of available systems is limited by the expensiveness. In addition, there is no one system that is 100% responsible to all medical and technical requirements, and would be completely safe for patient. Therefore, further research in the field of circu-latory support systems, considering health and technical requirements is relevant. One of the new directions in the study are disc pumps of viscous friction for liquid transporting, based on the Tesla pump principle. The operation principle of pumps based on the phenomenon of the boundary layer which is formed on the disk rotating in a fluid. There are experimental studies results of models with different variants of the rotor suspension, the various forms and the number of disks, forms the pump housing. However, none of the above samples was not brought to clinical trials. Furthermore, despite the promise of this model is still used today in some circulatory support systems are no similar type pump. Published data provide a basis for further development and testing of the pump model and allow to hope for leveling a number of significant shortcomings of modern left ventricular bypass systems.

  4. A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex.

    Science.gov (United States)

    Yamazaki, K; Umezu, M; Koyanagi, H; Kitamura, M; Eishi, K; Kawai, A; Tagusari, O; Niinami, H; Akimoto, T; Nojiri, C

    1992-01-01

    A new intraventricular axial flow blood pump has been designed and developed as an implantable left ventricular assist device (LVAD). The pump consists of a tube housing (10 cm in length and 14 mm in diameter), a three-vane impeller combined with a guide vane, and a DC motor. This pump is introduced into the LV cavity through the LV apex, and the outlet cannula is passed antegrade across the aortic valve. Blood is withdrawn from the LV through the inlet ports at the pump base, and discharged into the ascending aorta. A pump flow of > 8 L/min was obtained against 90 mmHg differential pressure in the mock circulatory system. In an acute dog model, this pump could produce a sufficient output of 200 ml/kg/min. In addition, the pump flow profile demonstrated a pulsatile pattern, although the rotation speed was fixed. This is mainly due to the changes in flow rate during a cardiac cycle--that is, during systole, the flow rate increases to the maximum, while the differential pressure between the LV and the aorta decreases to the minimum. Thus, this simple and compact axial flow blood pump can be a potential LVAD, with prompt accessibility and need for less invasive surgical procedures.

  5. A sliding mode-based starling-like controller for implantable rotary blood pumps.

    Science.gov (United States)

    Bakouri, Mohsen A; Salamonsen, Robert F; Savkin, Andrey V; AlOmari, Abdul-Hakeem H; Lim, Einly; Lovell, Nigel H

    2014-07-01

    Clinically adequate implementation of physiological control of a rotary left ventricular assist device requires a sophisticated technique such as the recently proposed method based on the Frank-Starling mechanism. In this mechanism, the stroke volume of the heart increases in response to an increase in the volume of blood filling the left ventricle at the end of diastole. To emulate this process, changes in pump speed need to automatically regulate pump flow to ensure that the combined output of the left ventricle and pump match the output of the right ventricle across changing cardiovascular states. In this approach, we exploit the linear relationship between estimated mean pump flow (Q ̅ est) and pump flow pulsatility (PIQp) in a tracking control algorithm based on sliding mode control. The immediate response of the controller was assessed using a lumped parameter model of the cardiovascular system (CVS) and pump from which could be extracted both Q ̅ est and PIQp. Two different perturbations from the resting state in the presence of left ventricular failure were tested. The first was blood loss requiring a reduction in pump flow to match the reduced output from the right ventricle and to avoid the complication of ventricular suction. The second was exercise, requiring an increase in pump flow. The sliding mode controller induced the required changes in Qp within approximately five heart beats in the blood loss simulation and eight heart beats in the exercise simulation without clinically significant transients or steady-state errors.

  6. Prediction of shear stress-related hemolysis in centrifugal blood pumps by computational fluid dynamics

    Institute of Scientific and Technical Information of China (English)

    WANG Fangqun; LI Lan; FENG Zhigang; QIAN Kunxi

    2005-01-01

    A quantitative evaluation of shear stress-related hemolysis in centrifugal blood pumps with different impeller designs has been investigated. Computational fluid dynamics (CFD) is applied to track the shear stress history of the streamlines of red cells. The power law model of the relations among the hemolysis, shear stress and exposure time is used to evaluate the hemolysis in the pumps.Hemolysis tests are also conducted to verify the estimations. Both the estimations and experimentally measured hemolysis levels show that the hemolysis in the streamlined impeller pump developed by the authors is lower than the pump with straight-vane under the same boundary conditions. The approach is proved to be acceptable and practical to predict hemolysis levels of blood pumps.

  7. Classification of physiologically significant pumping states in an implantable rotary blood pump: effects of cardiac rhythm disturbances.

    Science.gov (United States)

    Karantonis, Dean M; Lovell, Nigel H; Ayre, Peter J; Mason, David G; Cloherty, Shaun L

    2007-06-01

    Methods of speed control for implantable rotary blood pumps (iRBPs) are vital for providing implant recipients with sufficient blood flow to cater for their physiological requirements. The detection of pumping states that reflect the physiological state of the native heart forms a major component of such a control method. Employing data from a number of acute animal experiments, five such pumping states have been previously identified: regurgitant pump flow, ventricular ejection (VE), nonopening of the aortic valve (ANO), and partial collapse (intermittent [PVC-I] and continuous [PVC-C]) of the ventricle wall. An automated approach that noninvasively detects such pumping states, employing a classification and regression tree (CART), has also been developed. An extension to this technique, involving an investigation into the effects of cardiac rhythm disturbances on the state detection process, is discussed. When incorporating animal data containing arrhythmic events into the CART model, the strategy showed a marked improvement in detecting pumping states as compared to the model devoid of arrhythmic data: state VE--57.4/91.7% (sensitivity/specificity) improved to 97.1/100.0%; state PVC-I--66.7/83.1% improved to 100.0/88.3%, and state PVC-C--11.1/66.2% changed to 0.0/100%. With a simplified binary scheme differentiating suction (PVC-I, PVC-C) and nonsuction (VE, ANO) states, suction was initially detected with 100/98.5% sensitivity/specificity, whereas with the subsequent improved model, both these states were detected with 100% sensitivity. The accuracy achieved demonstrates the robustness of the technique presented, and substantiates its inclusion into any iRBP control methodology.

  8. Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model.

    Science.gov (United States)

    Wang, Shigang; Kunselman, Allen R; Myers, John L; Undar, Akif

    2008-01-01

    The purpose of this study was to compare two different blood pumps (Jostra roller pump vs. Medos deltastream DP1 rotary pump) on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant cardiopulmonary bypass (CPB) model. The Jostra and Medos pump were used in parallel pattern. The circuit was primed with lactated ringer's solution (700 ml) and the postfilter pressure was maintained at 100 mm Hg. Three transducers (postpump, postoxygenator and postfilter sites) of the Emboli Detection and Classification (EDAC) Quantifier were inserted into the CPB circuit to detect and classify gaseous microemboli. Trials were conducted at flow rates ranging from 500 to 1250 ml/min (250 ml/min increments). The arterial filter purge line was kept open during all trials. After injecting 20 ml air into the venous line, 2-minute segments of data were recorded simultaneously through three transducers. This entire process was repeated six times for each unique combination of blood pump, flow rate and perfusion mode, yielding a total of 96 experiments. Independent of perfusion mode and flow rate, Medos pump delivered less gaseous microemboli than Jostra pump at the postpump site, but only at 1,250 ml/min of pump flow rate the differences reached statistical significance (p < 0.01). There was no difference in delivery at the postfilter site. Compared with nonpulsatile flow, pulsatile flow transferred significantly more gaseous microemboli at the postpump site at 1,250 ml/min of pump flow rate in both groups (p < 0.01). The majority of gaseous microemboli were trapped by the membrane oxygenator. The results of this study confirm that rotary pump could deliver less gaseous microemboli than roller pump at the postpump site when a fixed volume air was introduced into the venous line. Pulsatile flow could transfer more gaseous microemboli at the postpump site, no matter which blood pump was used. Only few gaseous microemboli appeared at the postfilter

  9. Numerical study of a centrifugal blood pump with different impeller profiles.

    Science.gov (United States)

    Song, Guoliang; Chua, Leok Poh; Lim, Tau Meng

    2010-01-01

    Computational fluid dynamic simulations of the Kyoto-NTN magnetically suspended centrifugal blood pump with 16 forward-bending blades (16FB), 16 straight blades (16SB), and eight backward-bending blades (8BB) impellers were performed in this study. Commercial CFD software package FLUENT were used as the solver. The purpose of this study is to find out how the impeller blade profiles affect the inner flow and the performance of the centrifugal blood pump. The simulations were carried out with the same impeller rotating speed of 2,000 rpm and pump flow rate of 5 L/min to compare the three pump models. It was found that the 16SB impeller can produce higher pressure head than the 16FB and 8BB impellers under the same impeller rotating speed and pump flow rate. The flow particle tracing was carried out to estimate the blood damage level caused by the three different impeller profiles. It was found that the 16FB and 8BB models have caused the highest and lowest blood damage, respectively. The 16SB is recommended among the three pumps because it can generate the highest pressure head and induce mild blood damage index, although it was higher than that of the 8BB model.

  10. The status of failure and reliability testing of artificial blood pumps.

    Science.gov (United States)

    Patel, Sonna M; Throckmorton, Amy L; Untaroiu, Alexandrina; Allaire, Paul E; Wood, Houston G; Olsen, Don B

    2005-01-01

    Artificial blood pumps are today's most promising bridge-to-transplant, bridge-to-recovery, and destination therapy solutions for patients with congestive heart failure. There is a critical need for increased reliability and safety as the next generation of artificial blood pumps approach final development for long-term destination therapy. To date, extensive failure and reliability studies of these devices are considered intellectual property and thus remain unpublished. Presently, the Novacor N100PC, Thoratec VAD, and HeartMate LVAS (IP and XVE) comprise the only four artificial blood pumps commercially available for the treatment of congestive heart failure in the United States. The CardioWest TAH recently received premarket approval from the US Food and Drug Administration. With investigational device exemptions, the AB-180, AbioCor, LionHeart, DeBakey, and Flowmaker are approved for clinical testing. Other blood pumps, such as the American BioMed-Baylor TAH, CorAide, Cleveland Clinic-Nimbus TAH, HeartMate III, Hemadyne, and MagScrew TAH are currently in various stages of mock loop and animal testing, as indicated in published literature. This article extensively reviews in vitro testing, in vivo testing, and the early clinical testing of artificial blood pumps in the United States, as it relates to failure and reliability. This detailed literature review has not been published before and provides a thorough documentation of available data and testing procedures regarding failure and reliability of these various pumps.

  11. An investigational study of minimum rotational pump speed to avoid retrograde flow in three centrifugal blood pumps in a pediatric extracorporeal life support model.

    Science.gov (United States)

    Clark, Joseph B; Guan, Yulong; McCoach, Robert; Kunselman, Allen R; Myers, John L; Undar, Akif

    2011-05-01

    During extracorporeal life support with centrifugal blood pumps, retrograde pump flow may occur when the pump revolutions decrease below a critical value determined by the circuit resistance and the characteristics of the pump. We created a laboratory model to evaluate the occurrence of retrograde flow in each of three centrifugal blood pumps: the Rotaflow, the CentriMag, and the Bio-Medicus BP-50. At simulated patient pressures of 60, 80, and 100 mmHg, each pump was evaluated at speeds from 1000 to 2200 rpm and flow rates were measured. Retrograde flow occurred at low revolution speeds in all three centrifugal pumps. The Bio-Medicus pump was the least likely to demonstrate retrograde flow at low speeds, followed by the Rotaflow pump. The CentriMag pump showed the earliest transition to retrograde flow, as well as the highest degree of retrograde flow. At every pump speed evaluated, the Bio-Medicus pump delivered the highest antegrade flow and the CentriMag pump delivered the least.

  12. A suction detection system for rotary blood pumps based on the Lagrangian support vector machine algorithm.

    Science.gov (United States)

    Wang, Yu; Simaan, Marwan A

    2013-05-01

    The Left Ventricular Assist Device (LVAD) is a rotary mechanical pump that is implanted in patients with congestive heart failure to help the left ventricle in pumping blood in the circulatory system. However, using such a device may result in a very dangerous event, called ventricular suction that can cause ventricular collapse due to overpumping of blood from the left ventricle when the rotational speed of the pump is high. Therefore, a reliable technique for detecting ventricular suction is crucial. This paper presents a new suction detection system that can precisely classify pump flow patterns, based on a Lagrangian Support Vector Machine (LSVM) model that combines six suction indices extracted from the pump flow signal to make a decision about whether the pump is in suction, approaching suction, or not in suction. The proposed method has been tested using in vivo experimental data based on two different pumps. The simulation results show that the system can produce superior performance in terms of classification accuracy, stability, learning speed, and good robustness compared to three other existing suction detection methods and the original SVM-based algorithm. The ability of the proposed algorithm to detect suction provides a reliable platform for the development of a feedback control system to control the speed of the pump while at the same time ensuring that suction is avoided.

  13. Fluid dynamic characterization of operating conditions for continuous flow blood pumps.

    Science.gov (United States)

    Wu, Z J; Antaki, J F; Burgreen, G W; Butler, K C; Thomas, D C; Griffith, B P

    1999-01-01

    As continuous flow pumps become more prominent as long-term ventricular assist devices, the wide range of conditions under which they must be operated has become evident. Designed to operate at a single, best-efficiency, operating point, continuous flow pumps are required to perform at off-design conditions quite frequently. The present study investigated the internal fluid dynamics within two representative rotary fluid pumps to characterize the quality of the flow field over a full range of operating conditions. A Nimbus/UoP axial flow blood pump and a small centrifugal pump were used as the study models. Full field visualization of flow features in the two pumps was conducted using a laser based fluorescent particle imaging technique. Experiments were performed under steady flow conditions. Flow patterns at inlet and outlet sections were visualized over a series of operating points. Flow features specific to each pump design were observed to exist under all operating conditions. At off-design conditions, an annular region of reverse flow was commonly observed within the inlet of the axial pump, while a small annulus of backflow in the inlet duct and a strong disturbed flow at the outlet tongue were observed for the centrifugal pump. These observations were correlated to a critical nondimensional flow coefficient. The creation of a "map" of flow behavior provides an additional, important criterion for determining favorable operating speed for rotary blood pumps. Many unfavorable flow features may be avoided by maintaining the flow coefficient above a characteristic critical coefficient for a particular pump, whereas the intrinsic deleterious flow features can only be minimized by design improvement. Broadening the operating range by raising the band between the critical flow coefficient and the designed flow coefficient, is also a worthy goal for design improvement.

  14. The simulation of multiphase flow field in implantable blood pump and analysis of hemolytic capability

    Institute of Scientific and Technical Information of China (English)

    LI Tie-yan; YE Liang; HONG Fang-wen; LIU Deng-cheng; FAN Hui-min; LIU Zhong-min

    2013-01-01

    The numerical simulation of the axial flow impeller blood pump NIVADIII is carried out by using a CFD multiphase flow model.The hydrodynamic performance of the pump and the flow field in the pump are analyzed,and the shear stress distribution is obtained.A hemolytic prediction model based on the shear stress is built based on the calculation results,and it can be used for quantitative predictions of the hemolytic behavior of a blood pump.Hemolysis tests in vitro were performed 6 times with fresh bovine blood.At each time,the flow of the pump NIVADIII is 5 L/min and the outflow tract pressure is 100 mmHg.According to the tests,the plasma free hemoglobin (FHB) content and the hematocrit (HCT) are measured after 0 s,0.5 s,1 s,1.5 s,...4 s.At the end of each experiment Normal Index of Hemolysis (NIH) of NIVADIII is calculated.The average of NIH is 0.0055 g/100L,almost identical with that obtained from the hemolytic prediction model.This method can be applied in the selection stage of a blood pump.

  15. Extracorporeal gas exchange with the DeltaStream rotary blood pump in experimental lung injury.

    Science.gov (United States)

    Dembinski, Rolf; Kopp, Rüdger; Henzler, Dietrich; Hochhausen, Nadine; Oslender, Nicole; Max, Martin; Rossaint, Rolf; Kuhlen, Ralf

    2003-06-01

    In most severe cases of the acute respiratory distress syndrome, veno-venous extracorporeal membrane oxygenation (ECMO) can be used to facilitate gas exchange. However, the clinical use is limited due to the size and the concomitant risk of severe adverse events of conventionally-used centrifugal blood pumps with high extracorporeal blood volumes. The DeltaStream blood pump is a small-sized rotary blood pump that may reduce extracorporeal blood volume, foreign surfaces, contact activation of the coagulation system, and blood trauma. The aim of the present study was to test the safety and efficacy of the DeltaStream pump for ECMO in animals with normal lung function and experimental acute lung injury (ALI). Therefore, veno-venous ECMO was performed for 6 hours in mechanically ventilated pigs with normal lung function (n=6) and with ALI induced by repeated lung lavage (n=6) with a blood flow of 30% of the cardiac output. Gas flow with a FiO2 of 1.0 was set to equal blood flow. With a mean activated clotting time of 121 +/- 22 s, no circulatory impairment or thrombus formation was revealed during ECMO. Furthermore, free plasma Hb did not increase. In controls, hemodynamics and gas exchange remained unchanged. In animals with ALI, hemodynamics remained stable and gas transfer across the extracorporeal oxygenators was optimal, but only in 2 animals was a marked increase in PaO2 observed. CO2 removal was efficacious in all animals. We concluded that the DeltaStream blood pump may be used for veno-venous ECMO without major blood damage or hemodynamic impairment.

  16. Hemocompatibility of a hydrodynamic levitation centrifugal blood pump.

    Science.gov (United States)

    Yamane, Takashi; Maruyama, Osamu; Nishida, Masahiro; Kosaka, Ryo; Sugiyama, Daisuke; Miyamoto, Yusuke; Kawamura, Hiroshi; Kato, Takahisa; Sano, Takeshi; Okubo, Takeshi; Sankai, Yoshiyuki; Shigeta, Osamu; Tsutsui, Tatsuo

    2007-01-01

    A noncontact type centrifugal pump without any complicated control or sensing modules has been developed as a long-term implantable artificial heart. Centrifugal pumps with impellers levitated by original hydrodynamic bearings were designed and have been modified through numerical analyses and in vitro tests. The hemolysis level was reduced by changing the pressure distribution around the impeller and subsequently expanding the bearing gap. Thrombus formation in the bearing was examined with in vitro thrombogenesis tests and was reduced by changing the groove shapes to increase the bearing-gap flow to 3% of the external flow. Unnecessary vortices around the vanes were also eliminated by changing the number of vanes from four to six.

  17. Calcification in Chronically-Implanted Blood Pumps: Experimental Results and Review of the Literature

    OpenAIRE

    Turner, Stephen A.; Bossart, Mattie I.; Milam, John D.; Fuqua, John M.; Igo, Stephen R.; McGee, Michael G.; Frazier, O. Howard

    1982-01-01

    Blood compatibility is a major objective in the development of long-term, implantable circulatory assist (left ventricular assist devices) and replacement (total artificial heart) devices. An important problem in experimental studies in animals has been the propensity for calcification to occur at the blood/material interface. Presented is a summary of our experience (27 studies) with blood pump calcification and a review of the current literature regarding this complication.

  18. Impeller behavior and displacement of the VentrAssist implantable rotary blood pump.

    Science.gov (United States)

    Chung, Michael K H; Zhang, Nong; Tansley, Geoff D; Woodard, John C

    2004-03-01

    The VentrAssist implantable rotary blood pump, intended for long-term ventricular assist, is under development and is currently being tested for its rotor-dynamic stability. The pump is of the centrifugal type and consists of a shaftless impeller, also acting as the rotor of the brushless DC motor. The impeller remains passively suspended in the pump cavity by hydrodynamic forces, resulting from the small clearances between the impeller outside surfaces and the pump cavity. In the older version of the pump tested, these small clearances range from approximately 50 microm to 230 microm; the displacement of the impeller relative to the pump cavity is unknown in use. This article presents two experiments: the first measured displacement of the impeller using eddy-current proximity sensors and laser proximity sensors. The second experiment used Hall-effect proximity sensors to measure the displacement of the impeller relative to the pump cavity. All transducers were calibrated prior to commencement of the experiments. Voltage output from the transducers was converted into impeller movement in five degrees of freedom (x, y, z, theta(x), and theta(y)). The sixth degree of freedom, the rotation about the impeller axis (theta(z)), was determined by the commutation performed by the motor controller. The impeller displacement was found to be within the acceptable range of 8 micro m to 222 microm, avoiding blood damage and contact between the impeller and cavity walls. Thus the impeller was hydrodynamically suspended within the pump cavity and results were typical of centrifugal pump behavior. This research will be the basis for further investigation into the stiffness and damping coefficient of the pump's hydrodynamic bearing.

  19. Development of a Compact Maglev Centrifugal Blood Pump Enclosed in a Titanium Housing

    Science.gov (United States)

    Pai, Chi Nan; Shinshi, Tadahiko; Asama, Junichi; Takatani, Setsuo; Shimokohbe, Akira

    A compact centrifugal blood pump consisting of a controlled two-degrees-of-freedom radial magnetic bearing and a brushless DC motor enclosed in a titanium housing has been developed for use as an implantable ventricular assist device. The magnetic bearing also supports axial and angular motions of the impeller via a magnetic coupling. The top housing is made of pure titanium, while the impeller and the stator are coated with pure titanium and Ti-6Al-7Nb, respectively, to improve the biocompatibility of the pump. The combination of pure titanium and titanium alloy was chosen because of the sensitivity of eddy current type displacement sensors through the intervening conducting wall. The dimensions of the pump are 69.0 mm in diameter and 28.5 mm in height. During a pump performance test, axial shifting of the impeller due to hydraulic forces led to variations in the rotational positioning signal, causing loss of control of the rotational speed. This problem was solved by conditioning the rotational positioning signal. With a flow rate of 5 l/min against a head pressure of 100 mmHg, the power consumption and efficiency of the pump were 5.5 W and 20%, respectively. Furthermore, the hemolysis of the blood pump was 43.6% lower when compared to that of a commercially available pump.

  20. Pediatric ECMO outcomes: comparison of centrifugal versus roller blood pumps using propensity score matching.

    Science.gov (United States)

    Barrett, Cindy S; Jaggers, James J; Cook, E Francis; Graham, Dionne A; Yarlagadda, Vasmi V; Teele, Sarah A; Almond, Christopher S; Bratton, Susan L; Seeger, John D; Dalton, Heidi J; Rycus, Peter T; Laussen, Peter C; Thiagarajan, Ravi R

    2013-01-01

    Centrifugal blood pumps are being increasingly utilized in children supported with extracorporeal membrane oxygenation (ECMO). Our aim was to determine if survival and ECMO-related morbidities in children supported with venoarterial (VA) ECMO differed by blood pump type.Children aged less than 18 years who underwent VA ECMO support from 2007 to 2009 and reported to the Extracorporeal Life Support Organization registry were propensity score matched (Greedy 1:1 matching) using pre-ECMO characteristics.A total of 2,656 (centrifugal = 2,231, roller = 425) patients were identified and 548 patients (274 per pump type) were included in the propensity score-matched cohort. Children supported with centrifugal pumps had increased odds of hemolysis (odds ratio [OR], 4.03 95% confidence interval [CI], 2.37-6.87), hyperbilirubinemia (OR, 5.48; 95% CI, 2.62-11.49), need for inotropic support during ECMO (OR, 1.54; 95% CI, 1.09-2.17), metabolic alkalosis (blood pH > 7.6) during ECMO (OR, 3.13; 95% CI, 1.49-6.54), and acute renal failure (OR, 1.61; 95% CI, 1.10-2.39). Survival to hospital discharge did not differ by pump type.In a propensity score-matched cohort of pediatric ECMO patients, children supported with centrifugal pumps had increased odds of ECMO-related complications. There was no difference in survival between groups.

  1. Validation of an axial flow blood pump: computational fluid dynamics results using particle image velocimetry.

    Science.gov (United States)

    Su, Boyang; Chua, Leok Poh; Wang, Xikun

    2012-04-01

    A magnetically suspended axial flow blood pump is studied experimentally in this article. The pump casing enclosed a three-blade straightener, a two-blade impeller shrouded by a permanent magnet-embedded cylinder, and a three-blade diffuser. The internal flow fields were simulated earlier using computational fluid dynamics (CFD), and the pump characteristic curves were determined. The simulation results showed that the internal flow field was basically streamlined, except the diffuser region. Particle image velocimetry (PIV) measurement of the 1:1 pump model was conducted to validate the CFD result. In order to ensure the optical access, an acrylic prototype was fabricated with the impeller driven by a servomotor instead, as the magnet is opaque. In addition to the transparent model, the blood analog fluid with the refractive index close to that of acrylic was used to avoid refraction. According to the CFD results, the axial flow blood pump could generate adequate pressure head at the rotating speed of 9500rpm and flow rate of 5L/min, and the same flow condition was applied during the PIV measurement. Through the comparisons, it was found that the experimental results were close to those obtained by CFD and had thus validated the CFD model, which could complement the limitation of the measurement in assessing the more detailed flow fields of the axial flow pump.

  2. Blood warming, pump heating and haemolysis in low-flow extracorporeal life support; an in vitro study using freshly donated human blood.

    Science.gov (United States)

    Kusters, R W J; Simons, A P; Lancé, M D; Ganushchak, Y M; Bekers, O; Weerwind, P W

    2017-01-01

    Low-flow extracorporeal life support can be used for cardiopulmonary support of paediatric and neonatal patients and is also emerging as a therapy for patients suffering from exacerbation of chronic obstructive pulmonary disease. However, pump heating and haemolysis have proven to negatively affect the system and outcome. This in vitro study aimed at gaining insight into blood warming, pump heating and haemolysis related to the performance of a new low-flow centrifugal pump. Pump performance in the 400-1,500 ml/min flow range was modulated using small-sized dual-lumen catheters and freshly donated human blood. Measurements included plasma free haemoglobin, blood temperature, pump speed, pump pressure, blood flow and thermographic imaging. Blood warming (ΔTmax=0.5°C) had no relationship with pump performance or haemolysis (R(2)max=0.05). Pump performance-related parameters revealed no relevant relationships with haemolysis (R(2)max=0.36). Thermography showed no relevant heat zones in the pump (Tmax=36°C). Concerning blood warming, pump heating and haemolysis, we deem the centrifugal pump applicable for low-flow extracorporeal circulation.

  3. Analysis of optimal design configurations for a multiple disk centrifugal blood pump.

    Science.gov (United States)

    Miller, G E; Fink, R

    1999-06-01

    A multiple disk centrifugal pump was analyzed as a blood pump for use in cardiac assistance or as a bridge to transplant device. The original configuration consisted of 6 parallel disks with 0.016 inch spacing between disks. This pump suffered from a degradation of flow with increasing afterload. A study was conducted to analyze flow performance as a function of afterload, preload, and motor speed. Configurations were examined including 4, 5, and 6 disks each with spacings of 0.15, 0.20, and 0.25 inches. Flow rates were examined for variations in afterload from 60-130 mm Hg, in preload from 0-20 mm Hg and for motor speeds of 1,250, 1,500, and 1,750 rpm. Analyses of afterload effects were intended to determine those configurations that produced less flow degradation with increasing afterload. Analyses of motor speed effects were intended to determine any configurations that produced greater flow increases with increasing motor speed. A hemolysis study was also performed. Both plasma free hemoglobin and the index of hemolysis were compared to data reported for other centrifugal blood flow devices. Results indicated that a 5 disk configuration with a 0.15 inch spacing produced optimal flow results with minimal degradation at higher afterloads. No optimal configuration based upon motor speed was indicated. Preload effects on pump performance were minimal. Hemolysis results indicated minimal blood damage with levels below those of many other centrifugal blood pump designs.

  4. Numerical study of a bio-centrifugal blood pump with straight impeller blade profiles.

    Science.gov (United States)

    Song, Guoliang; Chua, Leok Poh; Lim, Tau Meng

    2010-02-01

    Computational fluid dynamic simulations of the flow in the Kyoto-NTN (Kyoto University, Kyoto, Japan) magnetically suspended centrifugal blood pump with a 16-straight-bladed impeller were performed in the present study. The flow in the pump was assumed as unsteady and turbulent, and blood was treated as a Newtonian fluid. At the impeller rotating speed of 2000 rpm and flow rate of 5 L/min, the pump produces a pressure head of 113.5 mm Hg according to the simulation. It was found that the double volute of the pump has caused symmetrical pressure distribution in the volute passages and subsequently caused symmetrical flow patterns in the blade channels. Due to the tangentially increasing pressure in the volute passages, the flow through the blade channels initially increases at the low-pressure region and then decreases due to the increased pressure. The reverse flow and vortices have been identified in the impeller blade channels. The high shear stress of the flow in the pump mainly occurred at the inlet and outlet of the blade channels, the beginning of the volute passages and the regions around the tips of the cutwater and splitter plate. Higher shear stress is obtained when the tips of the cutwater and splitter plate are located at the impeller blade trailing edges than when they are located at the middle of the impeller blade channel. It was found that the blood damage index assessed based on the blood corpuscle path tracing of the present pump was about 0.94%, which has the same order of magnitude as those of the clinical centrifugal pumps reported in the literature.

  5. Evaluation of erythrocyte flow at a bearing gap in a hydrodynamically levitated centrifugal blood pump.

    Science.gov (United States)

    Murashige, Tomotaka; Kosaka, Ryo; Sakota, Daisuke; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2015-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump for extracorporeal circulatory support. In the blood pump, a spiral groove bearing was adopted for a thrust bearing. In the spiral groove bearing, separation of erythrocytes and plasma by plasma skimming has been postulated to occur. However, it is not clarified that plasma skimming occurs in a spiral groove bearing. The purpose of this study is to verify whether plasma skimming occurs in the spiral groove bearing of a hydrodynamically levitated centrifugal blood pump. For evaluation of plasma skimming in the spiral groove bearing, an impeller levitation performance test using a laser focus displacement meter and a microscopic visualization test of erythrocyte flow using a high-speed microscope were conducted. Bovine blood diluted with autologous plasma to adjust hematocrit to 1.0% was used as a working fluid. Hematocrit on the ridge region in the spiral groove bearing was estimated using image analysis. As a result, hematocrits on the ridge region with gaps of 45 μm, 31 μm, and 25 μm were calculated as 1.0%, 0.6%, and 0.3%, respectively. Maximum skimming efficiency in this study was calculated as 70% with a gap of 25 μm. We confirmed that separation of erythrocyte and plasma occurred in the spiral groove bearing with decrease in bearing gap in a hydrodynamically levitated centrifugal blood pump.

  6. Numerical Analysis of Blood Damage Potential of the HeartMate II and HeartWare HVAD Rotary Blood Pumps.

    Science.gov (United States)

    Thamsen, Bente; Blümel, Bastian; Schaller, Jens; Paschereit, Christian O; Affeld, Klaus; Goubergrits, Leonid; Kertzscher, Ulrich

    2015-08-01

    Implantable left ventricular assist devices (LVADs) became the therapy of choice in treating end-stage heart failure. Although survival improved substantially and is similar in currently clinically implanted LVADs HeartMate II (HM II) and HeartWare HVAD, complications related to blood trauma are frequently observed. The aim of this study was to compare these two pumps regarding their potential blood trauma employing computational fluid dynamics. High-resolution structured grids were generated for the pumps. Newtonian flow was calculated, solving Reynolds-averaged Navier-Stokes equations with a sliding mesh approach and a k-ω shear stress transport turbulence model for the operating point of 4.5 L/min and 80 mm Hg. The pumps were compared in terms of volumes subjected to certain viscous shear stress thresholds, below which no trauma was assumed (von Willebrand factor cleavage: 9 Pa, platelet activation: 50 Pa, and hemolysis: 150 Pa), and associated residence times. Additionally, a hemolysis index was calculated based on a Eulerian transport approach. Twenty-two percent of larger volumes above 9 Pa were observed in the HVAD; above 50 Pa and 150 Pa the differences between the two pumps were marginal. Residence times were higher in the HVAD for all thresholds. The hemolysis index was almost equal for the HM II and HVAD. Besides the gap regions in both pumps, the inlet regions of the rotor and diffuser blades have a high hemolysis production in the HM II, whereas in the HVAD, the volute tongue is an additional site for hemolysis production. Thus, in this study, the comparison of the HM II and the HVAD using numerical methods indicated an overall similar tendency to blood trauma in both pumps. However, influences of turbulent shear stresses were not considered and effects of the pivot bearing in the HM II were not taken into account. Further in vitro investigations are required.

  7. Implantation of the VentrAssist Implantable Rotary Blood Pump in sheep.

    Science.gov (United States)

    James, Natalie L; van der Meer, Anita L; Edwards, Glenn A; Snelling, Samuel R; Begg, John D; Esmore, Donald S; Woodard, John C

    2003-01-01

    The VentrAssist Implantable Rotary Blood Pump (IRBP) is a hydrodynamically suspended, electromagnetically driven, centrifugal blood pump that provides continuous flow of up to 10 L/min at 3,000 rpm. In vivo studies in sheep were conducted to assess system design and performance. Surgery involved thoracotomy with subdiaphragmatic pump placement. Cannulae were transdiaphragmatic, with inflow in the left ventricular apex and outflow anastomosed to the descending aorta. Animals had no anticoagulation or antiplatelet therapy after surgery and no prophylactic antibiotics after recovery. Twelve sheep were supported for 622 pump days. Estimated pump flow ranged from 1 to 5.5 L/min at 1,800 to 2,000 rpm using 2.5 to 4.5 W. There was no clinical evidence of hemolysis or cardiovascular, renal, or hepatic dysfunction. Adverse outcomes included kinking/disconnection of the outflow cannula caused by the graft bend relief (n = 4), which was addressed through cannula redesign. Pump electrical malfunction (n = 4), caused by a silicone potting compound, was corrected using a neutral curing potting material. Surgical/husbandry issues (n = 2) also were addressed. The VentrAssist IRBP provides high flow at low rotational speed and power consumption. Further trials are in progress in advance of in vivo studies of the safety and efficacy of the final system.

  8. Plasma Skimming in a Spiral Groove Bearing of a Centrifugal Blood Pump.

    Science.gov (United States)

    Murashige, Tomotaka; Sakota, Daisuke; Kosaka, Ryo; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2016-09-01

    Plasma skimming is a phenomenon in which discharge hematocrit is lower than feed hematocrit in microvessels. Plasma skimming has been investigated at a bearing gap in a spiral groove bearing (SGB), as this has the potential to prevent hemolysis in the SGB of a blood pump. However, it is not clear whether plasma skimming occurs in a blood pump with the SGB, because the hematocrit has not been obtained. The purpose of this study is to verify plasma skimming in an SGB of a centrifugal blood pump by developing a hematocrit measurement method in an SGB. Erythrocyte observation using a high-speed microscope and a bearing gap measurement using a laser confocal displacement meter was performed five times. In these tests, bovine blood as a working fluid was diluted with autologous plasma to adjust the hematocrit to 1.0%. A resistor was adjusted to achieve a pressure head of 100 mm Hg and a flow rate of 5.0 L/min at a rotational speed of 2800 rpm. Hematocrit on the ridge region in the SGB was measured using an image analysis based on motion image of erythrocytes, mean corpuscular volume, the measured bearing gap, and a cross-sectional area of erythrocyte. Mean hematocrit on the ridge region in the SGB was linearly reduced from 0.97 to 0.07% with the decreasing mean bearing gap from 38 to 21 μm when the rotational speed was changed from 2250 to 3000 rpm. A maximum plasma skimming efficiency of 93% was obtained with a gap of 21 μm. In conclusion, we succeeded in measuring the hematocrit on the ridge region in the SGB of the blood pump. Hematocrit decreased on the ridge region in the SGB and plasma skimming occurred with a bearing gap of less than 30 μm in the hydrodynamically levitated centrifugal blood pump.

  9. Testing of a centrifugal blood pump with a high efficiency hybrid magnetic bearing.

    Science.gov (United States)

    Locke, Dennis H; Swanson, Erik S; Walton, James F; Willis, John P; Heshmat, Hooshang

    2003-01-01

    The purpose of this article is to present test results for a second generation, high efficiency, nonpulsatile centrifugal blood pump that is being developed for use as a left ventricular assist device (LVAD). The LVAD pump uses a hybrid passive-active magnetic bearing support system that exhibits extremely low power loss, low vibration, and high reliability under transient conditions and varying pump orientations. A unique feature of the second generation design configuration is the very simple and direct flow path for both main and washing blood flows. The pump was tested in both vertical and horizontal orientations using a standard flow loop to demonstrate the performance and durability of the second generation LVAD. Steady state and transient orientation pump operating characteristics including pressure, flow, speed, temperatures, vibration, and rotor orientation were measured. During the tests, pump performance was mapped at several operating conditions including points above and below the nominal design of 5 L/min at 100 mm Hg pressure rise. Flow rates from 2 to 7 L/min and pressure rises from 50 to 150 mm Hg were measured. Pump speeds were varied during these tests from 2,500 to 3,500 rpm. The nominal design flow of 5 L/min at 100 mm Hg pressure rise was successfully achieved at the design speed of 3,000 rpm. After LVAD performance testing, both 28 day continuous duty and 5 day transient orientation durability tests were completed without incident. A hydrodynamic backup bearing design feasibility study was also conducted. Results from this design study indicate that an integral hydrodynamic backup bearing may be readily incorporated into the second generation LVAD and other magnetically levitated pump rotors.

  10. PUMPS

    Science.gov (United States)

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  11. Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.

    Science.gov (United States)

    Malagutti, Nicolò; Karantonis, Dean M; Cloherty, Shaun L; Ayre, Peter J; Mason, David G; Salamonsen, Robert F; Lovell, Nigel H

    2007-01-01

    The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a mock loop under steady flow conditions for a variety of pump operating points and for various HCT levels. Analysis was performed using three-dimensional polynomial surfaces to fit the collected data for each different HCT level. The polynomial coefficients of the surfaces were then analyzed as a function of HCT. Linear correlations between estimated and measured pump flow over a flow range from 1.0 to 7.5 L/min resulted in a slope of 1.024 L/min (R2=0.9805). Early patient data tested against the estimator have shown promising consistency, suggesting that consideration of HCT can improve the accuracy of existing flow estimation algorithms.

  12. Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near-infrared light.

    Science.gov (United States)

    Sakota, Daisuke; Murashige, Tomotaka; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2014-09-01

    Blood coagulation is one of the primary concerns when using mechanical circulatory support devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is useful not only for the development of more hemocompatible devices but also for the management of blood coagulation to avoid risk of infarction. The objective of this study is to investigate the use of near-infrared light for imaging of thrombus formation in a rotary blood pump. The optical properties of a thrombus at wavelengths ranging from 600 to 750 nm were analyzed using a hyperspectral imaging (HSI) system. A specially designed hydrodynamically levitated centrifugal blood pump with a visible bottom area was used. In vitro antithrombogenic testing was conducted five times with the pump using bovine whole blood in which the activated blood clotting time was adjusted to 200 s prior to the experiment. Two halogen lights were used for the light sources. The forward scattering through the pump and backward scattering on the pump bottom area were imaged using the HSI system. HSI showed an increase in forward scattering at wavelengths ranging from 670 to 750 nm in the location of thrombus formation. The time at which the thrombus began to form in the impeller rotating at 2780 rpm could be detected. The spectral difference between the whole blood and the thrombus was utilized to image thrombus formation. The results indicate the feasibility of dynamically detecting and imaging thrombus formation in a rotary blood pump.

  13. A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests.

    Science.gov (United States)

    Leme, Juliana; Fonseca, Jeison; Bock, Eduardo; da Silva, Cibele; da Silva, Bruno Utiyama; Dos Santos, Alex Eugênio; Dinkhuysen, Jarbas; Andrade, Aron; Biscegli, José F

    2011-05-01

    A new model of blood pump for cardiopulmonary bypass (CPB) application has been developed and evaluated in our laboratories. Inside the pump housing is a spiral impeller that is conically shaped and has threads on its surface. Worm gears provide an axial motion of the blood column. Rotational motion of the conical shape generates a centrifugal pumping effect and improves pumping performance. One annular magnet with six poles is inside the impeller, providing magnetic coupling to a brushless direct current motor. In order to study the pumping performance, a mock loop system was assembled. Mock loop was composed of Tygon tubes (Saint-Gobain Corporation, Courbevoie, France), oxygenator, digital flowmeter, pressure monitor, electronic driver, and adjustable clamp for flow control. Experiments were performed on six prototypes with small differences in their design. Each prototype was tested and flow and pressure data were obtained for rotational speed of 1000, 1500, 2000, 2500, and 3000 rpm. Hemolysis was studied using pumps with different internal gap sizes (1.35, 1.45, 1.55, and 1.7 mm). Hemolysis tests simulated CPB application with flow rate of 5 L/min against total pressure head of 350 mm Hg. The results from six prototypes were satisfactory, compared to the results from the literature. However, prototype #6 showed the best results. Best hemolysis results were observed with a gap of 1.45 mm, and showed a normalized index of hemolysis of 0.013 g/100 L. When combined, axial and centrifugal pumping principles produce better hydrodynamic performance without increasing hemolysis.

  14. The Effect of Geometry on the Efficiency and Hemolysis of Centrifugal Implantable Blood Pumps.

    Science.gov (United States)

    Mozafari, Sahand; Rezaienia, Mohammad A; Paul, Gordon M; Rothman, Martin T; Wen, Pihua; Korakianitis, Theodosios

    The application of centrifugal pumps as heart assist devices imposes design limitations on the impeller geometry. Geometry and operating parameters will affect the performance and the hemocompatibility of the device. Among all the parameters affecting the hemocompatibility, pressure, rotational speed, blade numbers, angle, and width have significant impact on the blood trauma. These parameters directly (pressure, speed) and indirectly (geometry) affect the efficiency of the pump as well. This study describes the experimental investigation on geometric parameters and their effect on the performance of small centrifugal pumps suitable for Mechanical Circulatory Support (MCS) devices. Experimental and numerical techniques were implemented to analyze the performance of 15 centrifugal impellers with different characteristics. The effect of each parameter on the pump performance and hemolysis was studied by calculating the normalized index of hemolysis (NIH) and the shear stress induced in each pump. The results show five and six blades, 15-35° outlet angle, and the lowest outlet width that meets the required pressure rise are optimum values for an efficient hemocompatible pump.

  15. Prime Knowledge about Primes

    Science.gov (United States)

    Eisenberg, Theodore

    2007-01-01

    Several proofs demonstrating that there are infinitely many primes, different types of primes, tests of primality, pseudo primes, prime number generators and open questions about primes are discussed in Section 1. Some of these notions are elaborated upon in Section 2, with discussions of the Riemann zeta function and how algorithmic complexity…

  16. PIV Investigations of the Flow Field in the Volute of a Rotary Blood Pump

    Science.gov (United States)

    Sankovic, John M.; Kadambi, Jaikrishnan R.; Smith, William A.; Wernet, Mark P.

    2004-01-01

    A full-size acrylic model of a rotary blood pump was developed in order to utilize Particle Image Velocimetry (PIV) to make measurements of the fluid velocities and turbulent stresses throughout the device. The development of an understanding of the hemodynamics within the blood pump is critical to the development and validation of computational models. A blood analog solution, consisting of sodium iodide solution and glycerin, was developed to match physiological kinematic viscosity. The refractive indices of the fluid, the pump casing, and the impeller were matched to facilitate the use of PIV to make velocity measurements. Velocity measurements made in the volute exit/diffuser region are presented for pumps speeds of 3000-3850 rpm. At each speed data were obtained at a physiological pressure of 12 kPa and at a maximum flow condition. Four hundred data pairs were used for each resultant mean velocity vector value, representing greater than an order of magnitude more data pairs than reported previously in the literature on similar devices and resulting in velocity uncertainty levels of approximately 22.9%.

  17. Study of a centrifugal blood pump in a mock loop system.

    Science.gov (United States)

    Uebelhart, Beatriz; da Silva, Bruno Utiyama; Fonseca, Jeison; Bock, Eduardo; Leme, Juliana; da Silva, Cibele; Leão, Tarcísio; Andrade, Aron

    2013-11-01

    An implantable centrifugal blood pump (ICBP) is being developed to be used as a ventricular assist device (VAD) in patients with severe cardiovascular diseases. The ICBP system is composed of a centrifugal pump, a motor, a controller, and a power supply. The electricity source provides power to the controller and to a motor that moves the pump's rotor through magnetic coupling. The centrifugal pump is composed of four parts: external conical house, external base, impeller, and impeller base. The rotor is supported by a pivot bearing system, and its impeller base is responsible for sheltering four permanent magnets. A hybrid cardiovascular simulator (HCS) was used to evaluate the ICBP's performance. A heart failure (HF) (when the heart increases beat frequency to compensate for decrease in blood flow) was simulated in the HCS. The main objective of this work is to analyze changes in physiological parameters such as cardiac output, blood pressure, and heart rate in three situations: healthy heart, HF, and HF with left circulatory assistance by ICBP. The results showed that parameters such as aortic pressure and cardiac output affected by the HF situation returned to normal values when the ICBP was connected to the HCS. In conclusion, the test results showed satisfactory performance for the ICBP as a VAD.

  18. Fault-tolerant strategies for an implantable centrifugal blood pump using a radially controlled magnetic bearing.

    Science.gov (United States)

    Pai, Chi Nan; Shinshi, Tadahiko

    2011-10-01

    In our laboratory, an implantable centrifugal blood pump (CBP) with a two degrees-of-freedom radially controlled magnetic bearing (MB) to support the impeller without contact has been developed to assist the pumping function of the weakened heart ventricle. In order to maintain the function of the CBP after damage to the electromagnets (EMs) of the MB, fault-tolerant strategies for the CBP are proposed in this study. Using a redundant MB design, magnetic levitation of the impeller was maintained with damage to up to two out of a total of four EMs of the MB; with damage to three EMs, contact-free support of the impeller was achieved using hydrodynamic and electromagnetic forces; and with damage to all four EMs, the pump operating point, of 5 l/min against 100 mmHg, was achieved using the motor for rotation of the impeller, with contact between the impeller and the stator.

  19. Sodium pump α2 subunits control myogenic tone and blood pressure in mice

    Science.gov (United States)

    Zhang, Jin; Lee, Moo Yeol; Cavalli, Maurizio; Chen, Ling; Berra-Romani, Roberto; Balke, C William; Bianchi, Giuseppe; Ferrari, Patrizia; Hamlyn, John M; Iwamoto, Takahiro; Lingrel, Jerry B; Matteson, Donald R; Wier, W Gil; Blaustein, Mordecai P

    2005-01-01

    A key question in hypertension is: How is long-term blood pressure controlled? A clue is that chronic salt retention elevates an endogenous ouabain-like compound (EOLC) and induces salt-dependent hypertension mediated by Na+/Ca2+ exchange (NCX). The precise mechanism, however, is unresolved. Here we study blood pressure and isolated small arteries of mice with reduced expression of Na+ pump α1 (α1+/−) or α2 (α2+/−) catalytic subunits. Both low-dose ouabain (1–100 nm; inhibits only α2) and high-dose ouabain (≥1 μm; inhibits α1) elevate myocyte Ca2+ and constrict arteries from α1+/−, as well as α2+/− and wild-type mice. Nevertheless, only mice with reduced α2 Na+ pump activity (α2+/−), and not α1 (α1+/−), have elevated blood pressure. Also, isolated, pressurized arteries from α2+/−, but not α1+/−, have increased myogenic tone. Ouabain antagonists (PST 2238 and canrenone) and NCX blockers (SEA0400 and KB-R7943) normalize myogenic tone in ouabain-treated arteries. Only the NCX blockers normalize the elevated myogenic tone in α2+/− arteries because this tone is ouabain independent. All four agents are known to lower blood pressure in salt-dependent and ouabain-induced hypertension. Thus, chronically reduced α2 activity (α2+/− or chronic ouabain) apparently regulates myogenic tone and long-term blood pressure whereas reduced α1 activity (α1+/−) plays no persistent role: the in vivo changes in blood pressure reflect the in vitro changes in myogenic tone. Accordingly, in salt-dependent hypertension, EOLC probably increases vascular resistance and blood pressure by reducing α2 Na+ pump activity and promoting Ca2+ entry via NCX in myocytes. PMID:16166162

  20. A hydrodynamically suspended, magnetically sealed mechanically noncontact axial flow blood pump: design of a hydrodynamic bearing.

    Science.gov (United States)

    Mitamura, Yoshinori; Kido, Kazuyuki; Yano, Tetsuya; Sakota, Daisuke; Yambe, Tomoyuki; Sekine, Kazumitsu; OKamoto, Eiji

    2007-03-01

    To overcome the drive shaft seal and bearing problem in rotary blood pumps, a hydrodynamic bearing, a magnetic fluid seal, and a brushless direct current (DC) motor were employed in an axial flow pump. This enabled contact-free rotation of the impeller without material wear. The axial flow pump consisted of a brushless DC motor, an impeller, and a guide vane. The motor rotor was directly connected to the impeller by a motor shaft. A hydrodynamic bearing was installed on the motor shaft. The motor and the hydrodynamic bearing were housed in a cylindrical casing and were waterproofed by a magnetic fluid seal, a mechanically noncontact seal. Impeller shaft displacement was measured using a laser sensor. Axial and radial displacements of the shaft were only a few micrometers for motor speed up to 8500 rpm. The shaft did not make contact with the bearing housing. A flow of 5 L/min was obtained at 8000 rpm at a pressure difference of 100 mm Hg. In conclusion, the axial flow blood pump consisting of a hydrodynamic bearing, a magnetic fluid seal, and a brushless DC motor provided contact-free rotation of the impeller without material wear.

  1. Measurements of gap pressure and wall shear stress of a blood pump model.

    Science.gov (United States)

    Chua, L P; Akamatsu, T

    2000-04-01

    The centrifugal blood pump with a magnetically suspended impeller has shown its superiority as compared to other artificial hearts. However, there is still insufficient understanding of fluid mechanics related issues in the clearance gap. The design nature of the pump requires sufficient washout in the clearance between the impeller and stationary surfaces. As the gap is only 0.2 mm in width, it is very difficult to conduct measurements with present instrumentation. An enlarged model with 5:1 ratio of the pump has been designed and constructed according to specifications. Dimensionless gap pressure measurements of the model are very close to the prototype. The measurements of wall shear stress of the fluid flow in the clearance gap between the impeller face and inlet casing of a blood pump model were accomplished through hot-wire anemometry and rotating disk apparatus. Regions of relatively high and low shear stresses are identified. These correspond to spots where the likelihood of hemolysis and thrombus formation is high. With the use of dimensional analysis, it is found that the highest wall shear stress is equivalent to 146 Pa which is much lower than the threshold value of 400 Pa for hemolysis reported in the literature.

  2. Minimal sensor count approach to fuzzy logic rotary blood pump flow control.

    Science.gov (United States)

    Casas, Fernando; Ahmed, Nisar; Reeves, Andrew

    2007-01-01

    A rotary blood pump fuzzy logic flow controller without flow sensors was developed and tested in vitro. The controller, implemented in LabView, was set to maintain a flow set point in the presence of external pressure disturbances. Flow was estimated as a function of measured pump's delta P and speed, using a steady-state, nonlinear approximation. The fuzzy controller used the pump's flow estimate and delta P as feedback variables. The defuzzified control output manipulated the pump speed. Membership functions included flow error, delta P, and pump speed. Experimental runs in a mock loop (water/glycerin 3.5 cPs, 37 degrees C), using the estimated flow, were compared with those using a Transonic flow meter for nine conditions of flow and delta P (4 to 6 L/min, 150 to 350 mm Hg). Pressure disturbances generated by a servo pinch valve ranged from +/-23 to +/-47 mm Hg. Results indicated that the fuzzy controller ably regulated the flow set point to within +/-10% of the baseline even under large swings in pressure. There was no difference in controller performance between the ultrasonic flow measurement and the estimated flow calculation scenarios. These tests demonstrated that the fuzzy controller is capable of rejecting disturbances and regulating flow to acceptable limits while using a flow estimate.

  3. Electro-elastic modeling of a dielectric elastomer diaphragm for a prosthetic blood pump

    Science.gov (United States)

    Goulbourne, Nakhiah C.; Frecker, Mary I.; Mockensturm, Eric

    2004-07-01

    A dielectric elastomer diaphragm is to be designed for potential use in a prosthetic blood pump. Application of an electric field deforms the membrane such that it moves from an initially flat configuration to an inflated state. This motion creates positive displacement of blood from the cardiac chambers thus mimicking the pump-like behavior of the natural heart. A comprehensive large deformation model accounting for the combined dielectric and elastic effect has been formulated. This paper presents recent developments in the model to further incorporate the entire nonlinear range of material elastic behavior and to more accurately represent the applied electric field by keeping the voltage constant as the membrane thickness decreases. The updated model is used to calculate the effects of varying system parameters such as pressure, voltage, prestretch, material constants, and membrane geometry. Analytical results are obtained for biaxially stretched 3M VHB 4905 polyacrylate films.

  4. Effects of Diffuser on Self-priming Performance of Flow-ejecting Self-priming Centrifugal Pump%导流器对射流式自吸离心泵自吸性能的影响

    Institute of Scientific and Technical Information of China (English)

    刘建瑞; 文海罡; 向宏杰; 郭晨旭; 高振军

    2013-01-01

    A type of diffuser which had two asymmetrical exits and a separating flow board was placed at the inlet of the impeller of flow-ejecting self-priming centrifugal pump. The gap between the separating flow board and the impeller was 1. 0 mm. Based on Mixture multiphase flow model, the standard k - ε turbulence model and SIMPLE algorithm, unsteady numerical simulation of the self-priming process was carried out by using Fluent software. The distributions of pressure, velocity and gas-liquid phases field inside the pump, and also the changing regularity of pressure, gas phase volume flow rate and liquid mass flow rate on the two exits of the diffuser with the change of timestep were obtained. The results show that the pressure in the diffuser gradually increases along the direction of flow and appears larger change gradient, the pressure inside the each runner of the impeller approximate symmetric distribution. The flow parameters appear periodic change on the two asymmetrical exits of the diffuser. The gap between the separating flow board and impeller have not only prevented the formation of circulation of the fluid, reducing hydraulic loss and improving the efficiency of the pump, but also quicken the mixing of the gas-liquid near the gap, shortening the self-priming time of the pump.%在射流式自吸离心泵的叶轮出口处增设新型导流器,该导流器具有两个不对称出口及隔流板,隔流板与叶轮间隙为1.0 mm.基于Fluent软件提供的Mixture多相流模型、标准k-ε湍流模型及SIMPLE算法,对该泵的自吸过程进行了非定常数值模拟,得到了泵内压力、速度和气液两相分布及导流器两个出口的压力、气相体积流率和液相质量流率随时间步长的变化规律.结果表明:导流器内压力沿流体流动方向逐渐增大,并出现较大的变化梯度,叶轮各流道内的压力近似对称分布;导流器两个不对称出口气液混合物的各个流动参数呈规律的周期性变化

  5. Parameter estimation and actuator characteristics of hybrid magnetic bearings for axial flow blood pump applications.

    Science.gov (United States)

    Lim, Tau Meng; Cheng, Shanbao; Chua, Leok Poh

    2009-07-01

    Axial flow blood pumps are generally smaller as compared to centrifugal pumps. This is very beneficial because they can provide better anatomical fit in the chest cavity, as well as lower the risk of infection. This article discusses the design, levitated responses, and parameter estimation of the dynamic characteristics of a compact hybrid magnetic bearing (HMB) system for axial flow blood pump applications. The rotor/impeller of the pump is driven by a three-phase permanent magnet brushless and sensorless motor. It is levitated by two HMBs at both ends in five degree of freedom with proportional-integral-derivative controllers, among which four radial directions are actively controlled and one axial direction is passively controlled. The frequency domain parameter estimation technique with statistical analysis is adopted to validate the stiffness and damping coefficients of the HMB system. A specially designed test rig facilitated the estimation of the bearing's coefficients in air-in both the radial and axial directions. Experimental estimation showed that the dynamic characteristics of the HMB system are dominated by the frequency-dependent stiffness coefficients. By injecting a multifrequency excitation force signal onto the rotor through the HMBs, it is noticed in the experimental results the maximum displacement linear operating range is 20% of the static eccentricity with respect to the rotor and stator gap clearance. The actuator gain was also successfully calibrated and may potentially extend the parameter estimation technique developed in the study of identification and monitoring of the pump's dynamic properties under normal operating conditions with fluid.

  6. Noninvasive average flow and differential pressure estimation for an implantable rotary blood pump using dimensional analysis.

    Science.gov (United States)

    Lim, Einly; Karantonis, Dean M; Reizes, John A; Cloherty, Shaun L; Mason, David G; Lovell, Nigel H

    2008-08-01

    Accurate noninvasive average flow and differential pressure estimation of implantable rotary blood pumps (IRBPs) is an important practical element for their physiological control. While most attempts at developing flow and differential pressure estimate models have involved purely empirical techniques, dimensional analysis utilizes theoretical principles of fluid mechanics that provides valuable insights into parameter relationships. Based on data obtained from a steady flow mock loop under a wide range of pump operating points and fluid viscosities, flow and differential pressure estimate models were thus obtained using dimensional analysis. The algorithm was then validated using data from two other VentrAssist IRBPs. Linear correlations between estimated and measured pump flow over a flow range of 0.5 to 8.0 L/min resulted in a slope of 0.98 ( R(2) = 0.9848). The average flow error was 0.20 +/- 0.14 L/min (mean +/- standard deviation) and the average percentage error was 5.79%. Similarly, linear correlations between estimated and measured pump differential pressure resulted in a slope of 1.027 ( R(2) = 0.997) over a pressure range of 60 to 180 mmHg. The average differential pressure error was 1.84 +/- 1.54 mmHg and the average percentage error was 1.51%.

  7. Mathematical Modeling of Rotary Blood Pumps in a Pulsatile In Vitro Flow Environment.

    Science.gov (United States)

    Pirbodaghi, Tohid

    2017-01-18

    Nowadays, sacrificing animals to develop medical devices and receive regulatory approval has become more common, which increases ethical concerns. Although in vivo tests are necessary for development and evaluation of new devices, nonetheless, with appropriate in vitro setups and mathematical models, a part of the validation process can be performed using these models to reduce the number of sacrificed animals. The main aim of this study is to present a mathematical model simulating the hydrodynamic function of a rotary blood pump (RBP) in a pulsatile in vitro flow environment. This model relates the pressure head of the RBP to the flow rate, rotational speed, and time derivatives of flow rate and rotational speed. To identify the model parameters, an in vitro setup was constructed consisting of a piston pump, a compliance chamber, a throttle, a buffer reservoir, and the CentriMag RBP. A 40% glycerin-water mixture as a blood analog fluid and deionized water were used in the hydraulic circuit to investigate the effect of viscosity and density of the working fluid on the model parameters. First, model variables were physically measured and digitally acquired. Second, an identification algorithm based on regression analysis was used to derive the model parameters. Third, the completed model was validated with a totally different set of in vitro data. The model is usable for both mathematical simulations of the interaction between the pump and heart and indirect pressure measurement in a clinical context.

  8. Seal-less centrifugal blood pump with magnetically suspended rotor: rot-a-flot.

    Science.gov (United States)

    Mendler, N; Podechtl, F; Feil, G; Hiltmann, P; Sebening, F

    1995-07-01

    Limitations of current centrifugal blood pumps are related to heat generation of bearings and leakage of seals, to dead water zones, and to poor efficiency. A new concept is proposed in this paper to ameliorate these problems based on a miniaturized magnetic drive, and a prototype is introduced. The pump rotor is suspended and driven by a radial permanent magnetic field that stabilizes the impeller in 4 of the 6 spatial degrees of freedom and allows it to be top-spun on a single blood-flushed pivot bearing with minimal load and friction. A shrouded impeller with an open center and 4 logarithmically curved channels is run inside a cone-and-plate-type housing with a spiral volute chamber. In vitro testing was performed comparing this design with the BioMedicus, St. Jude, and Sarns pumps. The prototype is demonstrated to have the smallest internal volume (35 ml), surface (190 qcm), and passage time (0.5 s at 4 L/min), as well as the highest hydraulic efficiency (up to 0.4) of all devices studied.

  9. Computational assessment of the effects of a pulsatile pump on toxin removal in blood purification

    Directory of Open Access Journals (Sweden)

    Shim Eun

    2010-06-01

    Full Text Available Abstract Background For blood purification systems using a semipermeable membrane, the convective mass transfer by ultrafiltration plays an important role in toxin removal. The increase in the ultrafiltration rate can improve the toxin removal efficiency of the device, ultimately reducing treatment time and cost. In this study, we assessed the effects of pulsatile flow on the efficiency of the convective toxin removal in blood purification systems using theoretical methods. Methods We devised a new mathematical lumped model to assess the toxin removal efficiency of blood purification systems in patients, integrating the mass transfer model for a human body with a dialyser. The human body model consists of a three-compartment model of body fluid dynamics and a two-compartment model of body solute kinetics. We simulated three types of blood purification therapy with the model, hemofiltration, hemodiafiltration, and high-flux dialysis, and compared the simulation results in terms of toxin (urea and beta-2 microglobulin clearance and the treatment dose delivered under conditions of pulsatile and non-pulsatile pumping. In vivo experiments were also performed to verify the model results. Results Simulation results revealed that pulsatile flow improved the convective clearance of the dialyser and delivered treatment dose for all three types of therapy. Compared with the non-pulsatile pumping method, the increases in the clearance of urea and beta-2 microglobulin with pulsatile pumping were highest with hemofiltration treatment (122.7% and 122.7%, respectively, followed by hemodiafiltration (3.6% and 8.3%, respectively, and high-flux dialysis (1.9% and 4.7%, respectively. EKRc and std Kt/V averaged 28% and 23% higher, respectively, in the pulsatile group than in the non-pulsatile group with hemofiltration treatment. Conclusions The pulsatile effect was highly advantageous for all of the toxins in the hemofiltration treatment and for β2-microglobulin in

  10. Peristaltic Pumping of Blood in micro-vessels of Non-uniform Cross-section

    CERN Document Server

    Misra, J C

    2010-01-01

    The paper is devoted to a study of the peristaltic motion of blood in the micro-circulatory system. The vessel is considered of non-uniform cross-section. The progressive peristaltic waves are taken to be of sinusoidal nature. The Reynolds number is considered to be small. Blood is considered to be a Herschel-Bulkley fluid. Of particular concern here is to investigate the effects of amplitude ratio, mean pressure gradient, yield stress and the power law index on the velocity distribution, streamline pattern and wall shear stress. Basing upon the study, extensive numerical calculations has been made. The study reveals that peristaltic pumping as well as velocity and wall shear stress are appreciably affected due to the non-uniform geometry of blood vessels. They are also highly sensitive to the magnitude of the amplitude of the amplitude ratio and the value of the fluid index.

  11. Bearing gap adjustment for improvement of levitation performance in a hydrodynamically levitated centrifugal blood pump.

    Science.gov (United States)

    Kosaka, Ryo; Yoshida, Fumihiko; Nishida, Masahiro; Maruyama, Osamu; Kawaguchi, Yasuo; Yamane, Takashi

    2015-01-01

    The purpose of the present study is to investigate a bearing gap adjustment for improvement of levitation performance in a hydrodynamically levitated centrifugal blood pump to realize a blood pump with a low hemolysis level. The impeller levitates axially by balancing a gravitational force, buoyancy, a magnetic force, and hydrodynamic forces on the top and bottom sides of the impeller. To adjust the levitation position of the impeller, the balance of acting forces on the impeller was adjusted by changing the shroud area on the bottom impeller. Three pumps having various shroud area were prepared as tested models: 817 mm(2) (HH-S), 875 mm(2) (HH-M) and 931 mm(2) (HH-L). First, for evaluating the bearing gap adjustment, the bearing gap was estimated by calculating a balancing position of the acting forces on the impeller. We actually measured the gravitational force, buoyancy and the magnetic force, and numerically analyzed hydrodynamic forces on the top and bottom sides of the impeller. Second, to verify accuracy of the estimated bearing gap, the measurement test of the bearing gap was performed. Finally, an in-vitro hemolysis test was performed to evaluate a hemolysis level of the pump. As a result, bottom bearing gaps were estimated as 40 μm (HH-S), 60 μm (HH-M) and 238 μm (HH-L). In the measurement test, bottom bearing gaps were measured as 63 μm (HH-S), 219 μm (HH-M), and 231 μm (HH-L). The estimated bearing gaps had positively correlated with the measured bearing gaps in relation to the shroud area on the impeller. In the hemolysis test, hemolysis level in every model was almost equivalent to that of BPX-80, when the bearing gap was adjusted greater than 60 μm. We could adjust the bearing gap by changing the shroud area on the impeller for improvement of levitation performance to realize a blood pump with a low hemolysis level.

  12. In vivo experimental testing of the FW axial blood pump for left ventricular support in Fu Wai Hospital.

    Science.gov (United States)

    Zhang, Yan; Hu, Sheng-Shou; Zhou, Jian-Ye; Sun, Han-Song; Tang, Yue; Zhang, Hao; Zheng, Zhe; Li, Guo-Rong; Zhu, Xiao-Dong; Gui, Xin-Min

    2009-01-01

    A fully implantable, axial flow blood pump has been developed in Fu Wai Hospital aiming for clinical use. This ventricular assist device (VAD), which was developed after numerous CFD analyses for the flow characteristics of the pump, is 58.5-mm long, 30-mm wide (including DC motor), and weighs 240 g. The pump can deliver 5 L/min for pressures of 100 mm Hg over 8,000 rpm. In this study, short-term hemocompatibility effects of the axial left ventricular assist device (LVAD) (FW blood pump) were evaluated in four healthy sheep. The device was implanted into the left ventricular apex of beating hearts. The outflow graft of each device was anastomosed to the descending aorta. The hemolysis, which was evaluated in vivo by free hemoglobin value, was below 30 mg/dL. Evaluation of serum biochemical data showed that implantation of the FW blood pump in sheep with normal hearts did not impair end organ function. Gross and microscopic sections of kidney, liver, and lung revealed no evidence of microemboli. Performance of the pump in vivo was considered sufficient for a LVAD, although further design improvement is necessary in terms of hemolysis and antithrombosis to improve biocompatibility of the pump.

  13. Design and parameter estimation of hybrid magnetic bearings for blood pump applications

    Science.gov (United States)

    Lim, Tau Meng; Zhang, Dongsheng; Yang, Juanjuan; Cheng, Shanbao; Low, Sze Hsien; Chua, Leok Poh; Wu, Xiaowei

    2009-10-01

    This paper discusses the design and parameter estimation of the dynamics characteristics of a high-speed hybrid magnetic bearings (HMBs) system for axial flow blood pump applications. The rotor/impeller of the pump is driven by a three-phase permanent magnet (PM) brushless and sensorless DC motor. It is levitated by two HMBs at both ends in five-degree-of-freedom with proportional-integral-derivative (PID) controllers; among which four radial directions are actively controlled and one axial direction is passively controlled. Test results show that the rotor can be stably supported to speeds of 14,000 rpm. The frequency domain parameter estimation technique with statistical analysis is adopted to validate the stiffness and damping coefficients of the HMBs system. A specially designed test rig facilitated the estimation of the bearing's coefficients in air—in both the radial and axial directions. The radial stiffness of the HMBs is compared to the Ansoft's Maxwell 2D/3D finite element magnetostatic results. Experimental estimation showed that the dynamics characteristics of the HMBs system are dominated by the frequency-dependent stiffness coefficients. The actuator gain was also successfully calibrated and may potentially extend the parameter estimation technique developed in the study of identification and monitoring of the pump's dynamics properties under normal operating conditions with fluid.

  14. Noninvasive activity-based control of an implantable rotary blood pump: comparative software simulation study.

    Science.gov (United States)

    Karantonis, Dean M; Lim, Einly; Mason, David G; Salamonsen, Robert F; Ayre, Peter J; Lovell, Nigel H

    2010-02-01

    A control algorithm for an implantable centrifugal rotary blood pump (RBP) based on a noninvasive indicator of the implant recipient's activity level has been proposed and evaluated in a software simulation environment. An activity level index (ALI)-derived from a noninvasive estimate of heart rate and the output of a triaxial accelerometer-forms the noninvasive indicator of metabolic energy expenditure. Pump speed is then varied linearly according to the ALI within a defined range. This ALI-based control module operates within a hierarchical multiobjective framework, which imposes several constraints on the operating region, such as minimum flow and minimum speed amplitude thresholds. Three class IV heart failure (HF) cases of varying severity were simulated under rest and exercise conditions, and a comparison with other popular RBP control strategies was performed. Pump flow increases of 2.54, 1.94, and 1.15 L/min were achieved for the three HF cases, from rest to exercise. Compared with constant speed control, this represents a relative flow change of 30.3, 19.8, and -15.4%, respectively. Simulations of the proposed control algorithm exhibited the effective intervention of each constraint, resulting in an improved flow response and the maintenance of a safe operating condition, compared with other control modes.

  15. Optical Dynamic Analysis of Thrombus Inside a Centrifugal Blood Pump During Extracorporeal Mechanical Circulatory Support in a Porcine Model.

    Science.gov (United States)

    Fujiwara, Tatsuki; Sakota, Daisuke; Ohuchi, Katsuhiro; Endo, Shu; Tahara, Tomoki; Murashige, Tomotaka; Kosaka, Ryo; Oi, Keiji; Mizuno, Tomohiro; Maruyama, Osamu; Arai, Hirokuni

    2017-03-20

    Complications due to pump thrombus remain the weak point of mechanical circulatory support (MCS), such as the use of a left ventricular assist device (LVAD) or extracorporeal membrane oxygenation, leading to poor outcomes. Hyperspectral imaging (HSI) is an effective imaging method using a hyperspectral (HS) camera, which comprises a spectrophotometer and a charge-coupled device camera to discriminate thrombus from whole blood. Animal experiments were conducted to analyze dynamic imaging of thrombus inside a prototype of a hydrodynamically levitated centrifugal blood pump using an HSI system. Six pigs were divided into a venous circulation group (n = 3) and an arterial circulation group (n = 3). Inflow and outflow cannulae were inserted into the jugular veins in the venous circulation group. The latter simulated an LVAD application. To create thrombogenic conditions, pump flow was maintained at 1 L/min without anticoagulation. An image of the bottom surface of the pump was captured by the HS camera every 4 nm over the wavelength range of 608-752 nm. Real-time dynamic images of the inside of the pump were displayed on the monitor. Appearance of an area displaying thrombus was detected within 24 h after the start of the circulation in every experiment. This imaging system also succeeded in determining the origins of pump thrombus: from inside the pump in two cases, and from outside in four cases. Two main possible sources of pump thrombus originating outside the pump were identified on autopsy: wedge thrombus around the inflow cannula; and string-like thrombus at the junction between the pump inlet and circuit tube. The results of this study from close observation of the changing appearance of pump thrombus may contribute to improvements in the safety of extracorporeal MCS.

  16. Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

    Science.gov (United States)

    Watanabe, Nobuo; Masuda, Takaya; Iida, Tomoya; Kataoka, Hiroyuki; Fujimoto, Tetsuo; Takatani, Setsuo

    2005-01-01

    Secondary flow in the centrifugal blood pump helps to enhance the washout effect and to minimize thrombus formation. On the other hand, it has an adverse effect on pump efficiency. Excessive secondary flow may induce hemolytic effects. Understanding the secondary flow is thus important to the design of a compact, efficient, biocompatible blood pump. This study examined the secondary flow in a radial coupled centrifugal blood pump based on a simple particle tracking velocimetry (PTV) technique. A radial magnetically coupled centrifugal blood pump has a bell-shaped narrow clearance between the impeller inner radius and the pump casing. In order to vary the flow levels through the clearance area, clearance widths of 0.25 mm and 0.50 mm and impeller washout holes with diameters of 0 mm, 2.5 mm, and 4 mm were prepared. A high-speed video camera (2000 frames per second) was used to capture the particle images from which radial flow components were derived. The flow in the space behind the impeller was assumed to be laminar and Couette type. The larger the inner clearance or diameter of washout hole, the greater was the secondary flow rate. Without washout holes, the flow behind the impeller resulted in convection. The radial flow through the washout holes of the impeller was conserved in the radial as well as in the axial direction behind the impeller. The increase in the secondary flow reduced the net pump efficiency. Simple PTV was successful in quantifying the flow in the space behind the impeller. The results verified the hypothesis that the flow behind the impeller was theoretically Couette along the circumferential direction. The convection flow observed behind the impeller agreed with the reports of other researchers. Simple PTV was effective in understanding the fluid dynamics to help improve the compact, efficient, and biocompatible centrifugal blood pump for safe clinical applications.

  17. Evaluation of hydraulic radial forces on the impeller by the volute in a centrifugal rotary blood pump.

    Science.gov (United States)

    Boehning, Fiete; Timms, Daniel L; Amaral, Felipe; Oliveira, Leonardo; Graefe, Roland; Hsu, Po-Lin; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2011-08-01

    In many state-of-the-art rotary blood pumps for long-term ventricular assistance, the impeller is suspended within the casing by magnetic or hydrodynamic means. For the design of such suspension systems, profound knowledge of the acting forces on the impeller is crucial. Hydrodynamic bearings running at low clearance gaps can yield increased blood damage and magnetic bearings counteracting high forces consume excessive power. Most current rotary blood pump devices with contactless bearings are centrifugal pumps that incorporate a radial diffuser volute where hydraulic forces on the impeller develop. The yielding radial forces are highly dependent on impeller design, operating point and volute design. There are three basic types of volute design--singular, circular, and double volute. In this study, the hydraulic radial forces on the impeller created by the volute in an investigational centrifugal blood pump are evaluated and discussed with regard to the choice of contactless suspension systems. Each volute type was tested experimentally in a centrifugal pump test setup at various rotational speeds and flow rates. For the pump's design point at 5 L/min and 2500 rpm, the single volute had the lowest radial force (∼0 N), the circular volute yielded the highest force (∼2 N), and the double volute possessed a force of approx. 0.5 N. Results of radial force magnitude and direction were obtained and compared with a previously performed computational fluid dynamics (CFD) study.

  18. A cost-effective extracorporeal magnetically-levitated centrifugal blood pump employing a disposable magnet-free impeller.

    Science.gov (United States)

    Hijikata, W; Mamiya, T; Shinshi, T; Takatani, S

    2011-12-01

    In the field of rotary blood pumps, contactless support of the impeller by a magnetic bearing has been identified as a promising method to reduce blood damage and enhance durability. The authors developed a two-degrees-of-freedom radial controlled magnetic bearing system without a permanent magnet in the impeller in order that a low-cost disposable pump-head for an extracorporeal centrifugal blood pump could be manufactured more easily. Stable levitation and contactless rotation of the 'magnet-free' impeller were realized for a prototype blood-pump that made use of this magnetic bearing. The run-out of the impeller position at between 1000 r/min and 3000 r/min was less than 40 microm in the radial-controlled directions. The total power consumption of the magnetic bearing was less than 1 W at the same rotational speeds. When the pump was operated, a flow rate of 5 l/min against a head pressure of 78.66 kPa was achieved at a rotational speed of 4000 r/min, which is sufficient for extracorporeal circulation support. The proposed technology offers the advantage of low-cost mass production of disposable pump heads.

  19. Proton fluxes associated with the Ca pump in human red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Milanick, M.A. (Univ. of Missouri School of Medicine, Columbia (USA))

    1990-03-01

    Ca fluxes and H fluxes were measured in human red blood cells at 37 degrees C to characterize the effects of extracellular protons (Hout) on the Ca pump and to determine the stoichiometry of Ca-H exchange. A pH-stat technique was used to measure the rate of H influx, and 45Ca was used to determine the rate of Ca efflux. 4,4'-Diisothiocyanostilbene-2,2'-disulfonic acid (DIDS) was used to reduce proton permeability. A La-sensitive H influx was observed in Ca-loaded cells (Ca = 2 mmol/l packed cells) and was not observed in the cells loaded with vanadate as well as Ca. Similar results were obtained in Ca-loaded ghosts. The La dose-response curves for H influx and for Ca efflux were similar (50% inhibitory concentration (IC50) = approximately 5 microM) in intact red blood cells. The stoichiometry of the La-sensitive fluxes among different experiments ranged from 1.7 to 2.1 H/Ca when extracellular pH (pHout) = 6.3. Thus the Ca pump in intact red blood cells mediates Ca-2H exchange at pHout = 6.3. A 100-fold decrease in Hout (from pH 6.5 to 8.5; intracellular pH (pHin) approximately 7.4) only decreased Ca efflux 1.5- to 3-fold, hence Hout had little effect on the overall rate under the conditions studied. The small effect of Hout was a surprising result for a Ca-H exchange system, since one would have expected a steep dependence of Ca pump on Hout at Hout less than the Michaelis constant (Km). However, no La-sensitive H influx was observed when pHout = 8. On the basis of these data, it is suggested that the Ca pump also mediates Ca efflux uncoupled from H influx (Ca2+/phi H+). Ca efflux in the presence of 11 mM extracellular Ca (Caout) was one-fifth the value obtained in the absence of Caout at pHout = 8.5; this inhibition was reversed by increasing Hout (to pH 6.1).

  20. Fluid dynamic design for low hemolysis in a hydrodynamically levitated centrifugal blood pump.

    Science.gov (United States)

    Murashige, Tomotaka; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi; Kuwana, Katsuyuki; Kawaguchi, Yasuo

    2013-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump for extracorporeal circulatory support as a bridge to decision pump. The impeller is levitated using hydrodynamic bearings without any complicated control circuit or displacement sensor. However, the effect of the outer circumferential velocity and the bearing area on the hemolytic property has not been clarified, even if the bearing gap is same size. The purpose of this study is to experimentally evaluate the effect of the outer circumferential velocity and the bearing area in the bearing gaps on the hemolytic property in a hydrodynamically levitated centrifugal blood pump. We prepared three models for testing. These models have the same bearing gap size by adjusting the impeller levitation position. However, the outer circumferential velocity of the impeller and the bearing area in the minimum bearing gaps are different. The outer circumferential velocity of the impeller and the bearing area were assumed to be related to the maximum shear rate and the exposure time. For the evaluation, we conducted an impeller levitation performance test and an in vitro hemolysis test. As a result, the normalized index of hemolysis (NIH) was reduced from 0.084 g/100 L to 0.040 g/100 L corresponding to a reduction in the outer circumferential velocity and a reduction in the bearing area, even if the minimum bearing gaps were same size. We confirmed that, even if the bearing gap was same size under the stably levitated condition, the outer circumferential velocity and the bearing area should be decreased in order to improve the hemolytic property.

  1. A novel design of spiral groove bearing in a hydrodynamically levitated centrifugal rotary blood pump.

    Science.gov (United States)

    Han, Qing; Zou, Jun; Ruan, Xiaodong; Fu, Xin; Yang, Huayong

    2012-08-01

    Good washout is very important in spiral groove bearing (SGB) designs when applied to blood pumps due to the micrometer scales of lubrication films and groove depths. To improve washout, flow rate or leakage through SGBs should be as large as possible. However, this special goal violates conventional SGB designs in which no leakage is desired as the leakage would decrease load-carrying capacity significantly. So, a design concept is formed fulfilling the two goals of high load-carrying capacity and large flow rate: let groove width decrease along flow path and the mating surface of the rotor rotate with a direction facilitating the flow through the grooves. Under this concept, a novel SGB is designed, contrary to conventional ones, with groove width decreasing with increasing spiral radius. This SGB is mounted on the motionless upper plate of our designed centrifugal blood pump, with the mating surface of rotor rotating with a direction facilitating the outward flow. To assess SGB designs, a characteristic plane is originally presented relating to pressure-normalized load-carrying capacity and flow rate. Comparisons between various kinds of SGB designs are made, and computational fluid dynamics (CFD) results are plotted in this characteristic plane from which load/flow performances can be directly read out. CFD and comparison results show that the new designs have superior load/flow characteristics. However, the impact of SGB designs upon hemolysis/thrombus formation is still to be verified according to the concept presented.

  2. [Research on magnetic coupling centrifugal blood pump control based on a self-tuning fuzzy PI algorithm].

    Science.gov (United States)

    Yang, Lei; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Wang, Wei; Zhang, Haibo; Han, Lu; Xu, Liang

    2014-10-01

    The purpose of this paper is to report the research and design of control system of magnetic coupling centrifugal blood pump in our laboratory, and to briefly describe the structure of the magnetic coupling centrifugal blood pump and principles of the body circulation model. The performance of blood pump is not only related to materials and structure, but also depends on the control algorithm. We studied the algorithm about motor current double-loop control for brushless DC motor. In order to make the algorithm adjust parameter change in different situations, we used the self-tuning fuzzy PI control algorithm and gave the details about how to design fuzzy rules. We mainly used Matlab Simulink to simulate the motor control system to test the performance of algorithm, and briefly introduced how to implement these algorithms in hardware system. Finally, by building the platform and conducting experiments, we proved that self-tuning fuzzy PI control algorithm could greatly improve both dynamic and static performance of blood pump and make the motor speed and the blood pump flow stable and adjustable.

  3. 轴流式血泵流场CFD仿真%Flow field CFD analysis of axial flow blood pump

    Institute of Scientific and Technical Information of China (English)

    谢雄; 谭建平

    2014-01-01

    In the development of axial flow blood pump,the arterial partial flow field may produce an area with very low flow shear rate,so it is necessary to consider the non-Newtonian charac-teristics of blood fluid.In this paper,a model of axial flow blood pump was established,and flow and rotate-speed’s impacts on the inlet and outlet of the flow field in the blood pump were ana-lyzed through Computational Fluid Dynamics (CFD)simulation,as wel as the influence of the guide vane on the flow field.By the pump water experiment of the designed blood pump,its out-put flow and pressure were measured;the results show that the designed blood pump is consist-ent on the law with the simulation.%在轴流式血泵的研发过程中,动脉局部流场中可能产生流动剪切率非常低的区域,因此有必要考虑血液的非牛顿特性。建立了轴流式血泵模型,通过CFD仿真分析得到血泵转速和流量的变化对血泵出入口压力分布和速度分布的影响,并采用水和甘油(2∶1)的混合流体替代血液,对设计的血泵进行驱动实验,测量了轴流式血泵输出流量和压力参数。结果表明:所设计的血泵在规律上和仿真是相符的。

  4. 自吸泵启动过程气液两相流动的数值模拟%Numerical simulation on gas-liquid two-phase flow of self-priming pump during starting period

    Institute of Scientific and Technical Information of China (English)

    李红; 徐德怀; 涂琴; 成军; 李磊

    2013-01-01

    Self-priming pump is a kind of special centrifugal pump, which is widely used in irrigation and drainage, construction, mine drainage, city fire fighting, military, petrochemical industry, food industry and so on. The self-priming pumps produced in China have some problems such as complex structure, large size, difficulty for casting, low suction height, long self-priming time, and the design methods of the self-priming pump have still stayed in the semi-empirical theories stage, which can not meet the demand of predicting properties and the requirement of new products design. In order to know the flow rule, it becomes very important to research the inner flow of the self–priming pump. The self-priming transient process in self-priming pump is complex gas-liquid two-phase flow, gas-liquid mixing and separation performances play a crucial role during self-priming process. The self-priming pump typed 65ZB-40C was chosen as the numerical model. The three-dimensional model was generated in Pro/E software, and the three-dimensional unstructured grid was adopted in meshing in ICEM software because of the complexity of the geometric model. The gas-liquid two-phase flow field in a self-priming pump was simulated in FLUENT software by using VOF multiphase model, sliding mesh, and combined with the rotational speed curve of the impeller and the pressure curve of the pump outlet from tests. The PISO algorithm was used to handle the pressure-velocity coupling, and governing equations were discrete with second order upstream scheme. The model was initialized before computing, set the lower part of the pump for water, and the rest of the pump for air. Gas-liquid mixing and separation phenomena were simulated and the air volume fraction curves during starting period were obtained from monitoring points on the gas-liquid separation chamber inlet, the reflux hole, the cross-sections of volute and impeller. Results show that a gas-liquid mixing layer appeared at the outer edge of

  5. Current status of the gyro centrifugal blood pump--development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project).

    Science.gov (United States)

    Nosé, Yukihiko; Furukawa, Kojiro

    2004-10-01

    The New Energy and Industrial Technology Development Organization (NEDO) project was started in 1995. The goal is the development of a multipurpose, totally implantable biventricular assist device (BVAD) that can be used for any patient who suffers from severe heart failure. Our C1E3 (two-week pump) centrifugal pump, called the Gyro pump, has three design characteristics: a magnetic coupling and double pivot bearing system, an eccentric inlet port, and secondary vanes on the bottom of the impeller. The pump was miniaturized. The C1E3 evolved into the NEDO PI-601, a totally implantable centrifugal pump for BVAD. The current NEDO PI-710 pump (five-year pump) system includes a centrifugal pump with pivot bearings, a hydraulically-levitated impeller, an rpm-controlled miniaturized actuator (all-in-one actuator plus controller), an emergency clamp on the left outflow, and a Frank-Starling-type flow control. The final mass production model is now finalized, and the final animal study and two-year endurance studies are ongoing.

  6. Development of magnetic bearing system for a new third-generation blood pump.

    Science.gov (United States)

    Lee, Jung Joo; Ahn, Chi Bum; Choi, Jaesoon; Park, Jun Woo; Song, Seung-Joon; Sun, Kyung

    2011-11-01

    A magnetic bearing system is a crucial component in a third-generation blood pump, particularly when we consider aspects such as system durability and blood compatibility. Many factors such as efficiency, occupying volume, hemodynamic stability in the flow path, mechanical stability, and stiffness need to be considered for the use of a magnetic bearing system in a third-generation blood pump, and a number of studies have been conducted to develop novel magnetic bearing design for better handling of these factors. In this study, we developed and evaluated a new magnetic bearing system having a motor for a new third-generation blood pump. This magnetic bearing system consists of a magnetic levitation compartment and a brushless direct current (BLDC) motor compartment. The active-control degree of freedom is one; this control is used for controlling the levitation in the axial direction. The levitation in the radial direction has a passive magnetic levitation structure. In order to improve the system efficiency, we separated the magnetic circuit for axial levitation by using a magnetic circuit for motor drive. Each magnetic circuit in the bearing system was designed to have a minimum gap by placing mechanical parts, such as the impeller blades, outside the circuit. A custom-designed noncontact gap sensor was used for minimizing the system volume. We fabricated an experimental prototype of the proposed magnetic bearing system and evaluated its performance by a control system using the Matlab xPC Target system. The noncontact gap sensor was an eddy current gap sensor with an outer diameter of 2.38 mm, thickness of 0.88 mm, and resolution of 5 µm. The BLDC motor compartment was designed to have an outer diameter of 20 mm, length of 28.75 mm, and power of 4.5 W. It exhibited a torque of 8.6 mNm at 5000 rpm. The entire bearing system, including the motor and the sensor, had an outer diameter of 22 mm and a length of 97 mm. The prototype exhibited sufficient levitation

  7. Modeling study of the failing heart and its interaction with an implantable rotary blood pump.

    Science.gov (United States)

    Ramachandran, Deepa P; Luo, Chuan; Ma, Tony S; Clark, John W

    2011-01-01

    The effectiveness of clinical diagnosis and treatment of heart failure is a direct function of clinical signs that can be measured in a patient within cost and safety constraints. Large-scale mathematical modeling can be a key tool in revealing important, measurable clinical signs of heart failure, furthering medical understanding and development of treatment. In the first part of this study we have created two models of left heart failure--diastolic and systolic, using our human cardiovascular-respiratory system (H-CRS) model, and we present a comparison of the two types with emphasis on novel and differentiating clinical signs, such as tricuspid flow and septal motion. In the event of compromised left ventricular performance, mechanical left ventricular assist devices (LVAD) are often implanted to augment or completely replace the pumping action of the left ventricle (LV). One such type is the implantable rotary blood pump (iRBP). Several design issues related to the iRBP are difficult to study experimentally due to procedure complexity and limitations in animal models of heart failure [2]. Therefore, modeling has become a key tool in iRBP development. In the second part of this study, we have introduced an iRBP model based on [1]-[2] in the systolic failing heart to study the interactions. We consider optimal motor settings for different levels of LV assistance, the effects of the iRBP on the right heart, septum, and pulmonary circulation. Our model results align with those reported in [1]-[2]. Improvement in cardiac output, pulmonary congestion, and heart work are seen with the iRBP. We observe lowered septal assistance to RV and LV ejection with increasing pump speeds, elevating right ventricular (RV) work, reducing LVET, and causing ventricular mechanical dyssynchrony in ejection. These results suggest right heart compromise via the septum's reduced role with the introduction of an iRBP. This work emphasizes the critical role of modeling in heart failure and

  8. Noninvasive miniaturized mass-flow meter using a curved cannula for implantable axial flow blood pump.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2011-01-01

    Blood flow should be measured to monitor conditions of patients with implantable artificial hearts continuously and noninvasively. We have developed a noninvasive miniaturized mass-flow meter using a curved cannula for an axial flow blood pump. The mass-flow meter utilized centrifugal force generated by the mass-flow rate in the curved cannula. Two strain gauges served as sensors. Based on the numerical analysis, the first gauge, attached to the curved area, measured static pressure and centrifugal force, and the second, attached to the straight area, measured static pressure for static pressure compensation. The mass-flow rate was determined by the differences in output from the two gauges. To compensate for the inertia force under the pulsatile flow, a 0.75-Hz low-pass filter was added to the electrical circuit. In the evaluation tests, numerical analysis and an actual measurement test using bovine blood were performed to evaluate the measurement performances. As a result, in the numerical analysis, the relationship between the differential pressure caused by centrifugal force and the flow rate was verified. In the actual measurement test, measurement error was less than ± 0.5 L/min, and the time delay was 0.12 s. We confirmed that the developed mass-flow meter was able to measure mass-flow rate continuously and noninvasively.

  9. ADRC or adaptive controller--A simulation study on artificial blood pump.

    Science.gov (United States)

    Wu, Yi; Zheng, Qing

    2015-11-01

    Active disturbance rejection control (ADRC) has gained popularity because it requires little knowledge about the system to be controlled, has the inherent disturbance rejection ability, and is easy to tune and implement in practical systems. In this paper, the authors compared the performance of an ADRC and an adaptive controller for an artificial blood pump for end-stage congestive heart failure patients using only the feedback signal of pump differential pressure. The purpose of the control system was to provide sufficient perfusion when the patients' circulation system goes through different pathological and activity variations. Because the mean arterial pressure is equal to the total peripheral flow times the total peripheral resistance, this goal was converted to an expression of making the mean aortic pressure track a reference signal. The simulation results demonstrated that the performance of the ADRC is comparable to that of the adaptive controller with the saving of modeling and computational effort and fewer design parameters: total peripheral flow and mean aortic pressure with ADRC fall within the normal physiological ranges in activity variation (rest to exercise) and in pathological variation (left ventricular strength variation), similar to those values of adaptive controller.

  10. [Magnetic field numerical calculation and analysis for magnetic coupling of centrifugal blood pump for extracorporeal circulation].

    Science.gov (United States)

    Hu, Zhaoyan; Lu, Lijun; Zhang, Tianyi; Chen, Zhenglong; Zhang, Tao

    2013-12-01

    This paper mainly studies the driving system of centrifugal blood pump for extracorporeal circulation, with the core being disc magnetic coupling. Structure parameters of disc magnetic coupling are related to the ability of transferring magnetic torque. Therefore, it is necessary to carry out disc magnetic coupling permanent magnet pole number (n), air gap length (L(g)), permanent magnet thickness (L(m)), permanent magnet body inside diameter (R(i)) and outside diameter (R(o)), etc. thoroughly. This paper adopts the three-dimensional static magnetic field edge element method of Ansys for numerical calculation, and analyses the relations of magnetic coupling each parameter to transmission magnetic torque. It provides a good theory basis and calculation method for further optimization of the disc magnetic coupling.

  11. Shaft/shaft-seal interface characteristics of a multiple disk centrifugal blood pump.

    Science.gov (United States)

    Manning, K B; Miller, G E

    1999-06-01

    A multiple disk centrifugal pump (MDCP) is under investigation as a potential left ventricular assist device. As is the case with most shaft driven pumps, leakage problems around the shaft/shaft seal interface are of major interest. If leakage were to occur during or after implantation, potential events such as blood loss, clotting, blood damage, and/or infections might result in adverse effects for the patient. Because these effects could be quite disastrous, potential shaft and shaft seal materials have been investigated to determine the most appropriate course to limit these effects. Teflon and nylon shaft seals were analyzed as potential candidates along with a stainless steel shaft and a Melonite coated shaft. The materials and shafts were evaluated under various time durations (15, 30, 45, and 60 min), motor speeds (800, 1,000, 1,200, and 1,400 rpm), and outer diameters (1/2 and 3/4 inches). The motor speed and geometrical configurations were typical for the MDCP under normal physiologic conditions. An air and water study was conducted to analyze the inner diameter wear, the inner temperature values, and the outer temperature values. Statistical comparisons were computed for the shaft seal materials, the shafts, and the outer diameters along with the inner and outer temperatures. The conclusions made from the results indicate that both the tested shaft seal materials and shaft materials are not ideal candidates to be used for the MDCP. Teflon experienced a significant amount of wear in air and water studies. Nylon did experience little wear, but heat generation was an evident problem. A water study on nylon was not conducted because of its molecular structure.

  12. Investigating the impact of non-Newtonian blood models within a heart pump.

    Science.gov (United States)

    Al-Azawy, Mohammed G; Turan, A; Revell, A

    2017-01-01

    A detailed computational fluid dynamics (CFD) study of transient, turbulent blood flow through a positive displacement left ventricular assist device is performed. Two common models for non-Newtonian blood flow are compared to the Newtonian model to investigate their impact on predicted levels of shear rate and wall shear stress. Given that both parameters are directly relevant to the evaluation of risk from thrombus and haemolysis, there is a need to assess the sensitivity to modelling non-Newtonian flow effects within a pulsatile turbulent flow, in order to identify levels of uncertainly in CFD. To capture the effects of turbulence, the elliptic blending Reynolds stress model is used in the present study, on account of superior performance of second moment closure schemes previously identified by the present authors. The CFD configuration includes two cyclically rotating valves and a moving pusher plate to periodically vary the chamber volume. An overset mesh algorithm is used for each instance of mesh motion, and a zero gap technique was employed to ensure full valve closure. The left ventricular assist device was operated at a pumping rate of 86 BPM (beats per minute) and a systolic duration of 40% of the pumping cycle, in line with existing experimental data to which comparisons are made. The sensitivity of the variable viscosity models is investigated in terms of mean flow field, levels of turbulence and global shear rate, and a non-dimensional index is used to directly evaluate the impact of non-Newtonian effects. The clinical relevance of the results is reported along with a discussion of modelling uncertainties, observing that the turbulent kinetic energy is generally predicted to be higher in non-Newtonian flow than that observed in Newtonian flow. Copyright © 2016 John Wiley & Sons, Ltd.

  13. 蜗壳回流孔对自吸泵性能的影响%Effects of reflux hole of volute on the performance of self-priming pump

    Institute of Scientific and Technical Information of China (English)

    夏丽; 武鹏; 吴大转

    2015-01-01

    回流孔在自吸泵中通过液体回流蜗壳的方式达到改善自吸性能的目的,其位置和面积大小对自吸性能和效率有着显著影响。利用计算流体力学分析方法对带回流孔的自吸泵内部流动进行数值模拟,研究回流孔附近的流动特性,分析不同回流孔位置和面积对内部流动和泵性能的影响。结果显示,基于内流模拟预测的自吸泵性能与试验结果趋势吻合。在设计工况下,增大回流孔面积可使回流蜗壳的流量增大,在不降低泵性能的情况下明显改善泵的自吸性能;在大流量工况下,回流孔面积的增大导致蜗壳到气液分离室的泄露,从而带来较大的容积损失。回流孔在环向的位置主要对蜗壳内外压差产生影响,随着回流孔向隔舌靠近,蜗壳与气液分离室的压差逐渐变大,从蜗壳到气液分离室的泄漏损失增大,泵的效率降低。因此,对于特定的自吸泵,存在一个最佳的回流孔开孔面积和位置。%Reflux hole helps self‐priming pumps to improve self‐priming performance w hen the re‐flux liquid flow s into volute .Its position and area have a great influence on the self‐priming capa‐bility and efficiency of the pump .The internal flow field of the self‐priming pump was numerical‐ly simulated with the CFD method ,to study the flow characteristics nearby the reflux hole and analyze the impact of the position and area of the reflux hole on the internal flow as well as the pump performance . The simulation results showed that the tendencies of simulation results matched with the experimental data .When the pump was operated at its design point ,the reflux flow rate increased with the area of the reflux hole and consequently the self‐priming capability was improved without suppressing the pump performance .When the flow rate was larger than the nominal flow rate ,the increase of the area of the reflux hole leaded to the

  14. The peripheral blood fibrocyte is a potent antigen-presenting cell capable of priming naive T cells in situ.

    Science.gov (United States)

    Chesney, J; Bacher, M; Bender, A; Bucala, R

    1997-06-10

    Recent studies have identified a novel population of blood-borne cells, termed fibrocytes, that have a distinct cell surface phenotype (collagen+/CD13(+)/CD34(+)/CD45(+)), rapidly enter sites of tissue injury, and synthesize connective tissue matrix molecules. We found by flow cytometry that purified human fibrocytes express each of the known surface components that are required for antigen presentation, including class II major histocompatability complex molecules (HLA-DP, -DQ, and -DR), the costimulatory molecules CD80 and CD86, and the adhesion molecules CD11a, CD54, and CD58. Human fibrocytes induced antigen-presenting cell-dependent T cell proliferation when cultured with specific antigen and this proliferative activity was significantly higher than that induced by monocytes and nearly as high as that induced by purified dendritic cells. Mouse fibrocytes also were found to express the surface components required for antigen presentation and to function as potent APCs in vitro. Mouse fibrocytes pulsed in vitro with the HIV-proteins p24 or gp120 and delivered to a site of cutaneous injury were found to migrate to proximal lymph nodes and to specifically prime naive T cells. These data suggest that fibrocytes play an early and important role in the initiation of antigen-specific immunity.

  15. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature 1

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-01-01

    ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. PMID:27533272

  16. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Directory of Open Access Journals (Sweden)

    Ana Maria Miranda Martins Wilson

    Full Text Available ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.

  17. Computational fluid dynamics-based hydraulic and hemolytic analyses of a novel left ventricular assist blood pump.

    Science.gov (United States)

    Yang, Xiao-Chen; Zhang, Yan; Gui, Xing-Min; Hu, Sheng-Shou

    2011-10-01

    The advent of various technologies has allowed mechanical blood pumps to become more reliable and versatile in recent decades. In our study group, a novel structure of axial flow blood pump was developed for assisting the left ventricle. The design point of the left ventricular assist blood pump 25 (LAP-25) was chosen at 4 Lpm with 100 mm Hg according to our clinical practice. Computational fluid dynamics was used to design and analyze the performance of the LAP-25. In order to obtain a required hydraulic performance and a satisfactory hemolytic property in the LAP-25 of a smaller size, a novel structure was developed including an integrated shroud impeller, a streamlined impeller hub, and main impeller blades with splitter blades; furthermore, tandem cascades were introduced in designing the diffuser. The results of numerical simulation show the LAP-25 can generate flow rates of 3-5 Lpm at rotational speeds of 8500-10,500 rpm, producing pressure rises of 27.5-148.3 mm Hg with hydraulic efficiency points ranging from 13.4 to 27.5%. Moreover, the fluid field and the hemolytic property of the LAP-25 were estimated, and the mean hemolysis index of the pump was 0.0895% with Heuser's estimated model. In conclusion, the design of the LAP-25 shows an acceptable result.

  18. Geometric optimization of a step bearing for a hydrodynamically levitated centrifugal blood pump for the reduction of hemolysis.

    Science.gov (United States)

    Kosaka, Ryo; Yada, Toru; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2013-09-01

    A hydrodynamically levitated centrifugal blood pump with a semi-open impeller has been developed for mechanical circulatory assistance. However, a narrow bearing gap has the potential to cause hemolysis. The purpose of the present study is to optimize the geometric configuration of the hydrodynamic step bearing in order to reduce hemolysis by expansion of the bearing gap. First, a numerical analysis of the step bearing, based on lubrication theory, was performed to determine the optimal design. Second, in order to assess the accuracy of the numerical analysis, the hydrodynamic forces calculated in the numerical analysis were compared with those obtained in an actual measurement test using impellers having step lengths of 0%, 33%, and 67% of the vane length. Finally, a bearing gap measurement test and a hemolysis test were performed. As a result, the numerical analysis revealed that the hydrodynamic force was the largest when the step length was approximately 70%. The hydrodynamic force calculated in the numerical analysis was approximately equivalent to that obtained in the measurement test. In the measurement test and the hemolysis test, the blood pump having a step length of 67% achieved the maximum bearing gap and reduced hemolysis, as compared with the pumps having step lengths of 0% and 33%. It was confirmed that the numerical analysis of the step bearing was effective, and the developed blood pump having a step length of approximately 70% was found to be a suitable configuration for the reduction of hemolysis.

  19. A quantitative visualization study of flow in a scaled-up model of a centrifugal blood pump.

    Science.gov (United States)

    Ikeda, T; Yamane, T; Orita, T; Tateishi, T

    1996-02-01

    A quantitative flow visualization study of a scaled-up model of a centrifugal blood pump was performed. Since the size of the scaled-up model was three times as large as the original pump under development, and the kinematic viscosity of the saline solution used as the working fluid was approximately one-third that of the blood, we obtained a similar flow at one twenty-seventh the angular velocity of the original pump. The flow was visualized by seeding the saline solution with neutrally buoyant particles and by illuminating the model with a laser light sheet. Since the gap flow behind the impeller is important for thrombus formation, it was recorded by a high-speed video camera, and the velocity field was evaluated automatically by particle tracking velocimetry. It was shown that in the gap behind the impeller there existed a region where the velocity profile was almost flat which can be called a core region. The results indicated the effectiveness of the present visualization technique for centrifugal blood pumps.

  20. Human T cell priming assay: depletion of peripheral blood lymphocytes in CD25(+) cells improves the in vitro detection of weak allergen-specific T cells.

    Science.gov (United States)

    Vocanson, Marc; Achachi, Amine; Mutez, Virginie; Cluzel-Tailhardat, Magalie; Varlet, Béatrice Le; Rozières, Aurore; Fournier, Philippe; Nicolas, Jean-François

    2014-01-01

    To develop an in vitro assay that recapitulates the key event of allergic contact dermatitis (ACD), that is the priming of effector T cells by hapten-presenting dendritic cells, and then allows for the sensitive detection of chemical allergens represents a major challenge. Classical human T cell priming assays (hTCPA) that have been developed in the past, using hapten-loaded monocyte-derived dendritic cells (MDDCs) as antigen-presenting cells and peripheral blood lymphocytes (PBLs) as responding cells, were not efficient to prime T cells to common allergens with moderate/weak sensitizing properties. Recent progress in the understanding of the effector and regulatory mechanisms of ACD have shown that T cell priming requires efficient uptake of allergens by immunogenic DCs and that it is controlled by several subsets of regulatory cells including CD25(+) Tregs. We therefore analyzed various parameters involved in allergen-specific T cell activation in vitro and showed that priming of allergen-specific T cells is hampered by several subsets of immune cells comprising CD1a(neg) DCs, CD25(+) T cells, and CD56(+) regulatory cells.CD4(+)CD25(+)FoxP3(+) Tregs prevented the in vitro T cell priming to moderate/weak allergens, and depletion of human PBLs in CD25(+) cells significantly increased specific T cell proliferation and IFN-γ secretion. CD56(+) cells exerted an additional control of T cell priming since co-depletion of both CD56(+) and CD25(+) cells improved the magnitude of chemical-specific T cell activation. Finally, CD1a(low) MDDCs were able to inhibit T cell activation obtained by allergen-pulsed CD1a(high) MDDC. Moreover, we showed that uptake by DC of allergen-encapsulated nanoparticles significantly increased their activation status and their ability to prompt specific T cell activation. Hence, by combining the different strategies, i.e., depletion of CD25(+) and CD56(+) cells, use of CD1a(high) MDDC, and nanoparticle encapsulation of allergens, it was

  1. Viscosity-adjusted estimation of pressure head and pump flow with quasi-pulsatile modulation of rotary blood pump for a total artificial heart.

    Science.gov (United States)

    Yurimoto, Terumi; Hara, Shintaro; Isoyama, Takashi; Saito, Itsuro; Ono, Toshiya; Abe, Yusuke

    2016-09-01

    Estimation of pressure and flow has been an important subject for developing implantable artificial hearts. To realize real-time viscosity-adjusted estimation of pressure head and pump flow for a total artificial heart, we propose the table estimation method with quasi-pulsatile modulation of rotary blood pump in which systolic high flow and diastolic low flow phased are generated. The table estimation method utilizes three kinds of tables: viscosity, pressure and flow tables. Viscosity is estimated from the characteristic that differential value in motor speed between systolic and diastolic phases varies depending on viscosity. Potential of this estimation method was investigated using mock circulation system. Glycerin solution diluted with salty water was used to adjust viscosity of fluid. In verification of this method using continuous flow data, fairly good estimation could be possible when differential pulse width modulation (PWM) value of the motor between systolic and diastolic phases was high. In estimation under quasi-pulsatile condition, inertia correction was provided and fairly good estimation was possible when the differential PWM value was high, which was not different from the verification results using continuous flow data. In the experiment of real-time estimation applying moving average method to the estimated viscosity, fair estimation could be possible when the differential PWM value was high, showing that real-time viscosity-adjusted estimation of pressure head and pump flow would be possible with this novel estimation method when the differential PWM value would be set high.

  2. Preload-based Starling-like control of rotary blood pumps: An in-vitro evaluation

    Science.gov (United States)

    Gregory, Shaun D.; Salamonsen, Robert F.; Lovell, Nigel H.; Stevens, Michael C.; Pauls, Jo P.; Akmeliawati, Rini; Lim, Einly

    2017-01-01

    Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow (QP¯) with respect to mean left ventricular end diastolic pressure (PLVEDm) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVEDm) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased QP¯ by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVEDm of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and QP¯ with CSC, whilst the SLC maintained MAP and QP¯. The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation. PMID:28212401

  3. Design analysis and performance assessment of hybrid magnetic bearings for a rotary centrifugal blood pump.

    Science.gov (United States)

    Ren, Zhaohui; Jahanmir, Said; Heshmat, Hooshang; Hunsberger, Andrew Z; Walton, James F

    2009-01-01

    A hybrid magnetic bearing system was designed for a rotary centrifugal blood pump being developed to provide long-term circulatory support for heart failure patients. This design consists of two compact bearings to suspend the rotor in five degrees-of-freedom with single axis active control. Permanent magnets are used to provide passive radial support and electromagnets to maintain axial stability of the rotor. Characteristics of the passive radial and active thrust magnetic bearing system were evaluated by the electromagnetic finite element analysis. A proportional-integral-derivative controller with force balance algorithm was implemented for closed loop control of the magnetic thrust bearing. The control position is continuously adjusted based on the electrical energy in the bearing coils, and thus passive magnetic forces carry static thrust loads to minimize the bearing current. Performance of the magnetic bearing system with associated control algorithm was evaluated at different operating conditions. The bearing current was significantly reduced with the force balance control method and the power consumption was below 0.5 W under various thrust loads. The bearing parameters predicted by the analysis were validated by the experimental data.

  4. In vitro study to estimate particle release from a centrifugal blood pump.

    Science.gov (United States)

    Takami, Yoshiyuki

    2006-05-01

    Centrifugal pumps have been increasingly used in clinical settings. Like roller pumps, centrifugal pumps can cause debris release due to mechanical stress. The objectives of this study were to evaluate in vitro the particle release from a centrifugal pump, Gyro Pump (Japan Medical Materials Co., Osaka, Japan), which is a pivot-bearing supported pump clinically used in Japan, and to identify the released particles. In the clean room Class 10,000, the pump was operated for 24 h at 4000 rpm and 6 L/min in a mock loop filled with lactated Ringer's solution. After 24 h, the sample fluid and a blank were filtered with a 0.45-microm membrane filter for microscopic counting, followed by observation with a scanning electron microscope and element analysis with an X-ray spectrometer. Microscopic countings were 128 +/- 42 in the test samples (n = 10) of the Gyro Pump and 98 +/- 42 in the blank samples (n = 10) (P = 0.12). The oxygen/carbon atomic ratio of the particles in the test samples was 0.32 +/- 0.06, which was similar to the ratio of the particles in the blank sample (0.34 +/- 0.06). The profiles of elements with an X-ray spectrometer showed that the released particles from the Gyro Pump were not derived from the pump materials. In conclusion, an in vitro test system has been established for estimation of particle release from a centrifugal pump. Based upon the results with the system, the Gyro Pump with a pivot-bearing system has little risk to release debris particles even in a severe condition.

  5. The spiral groove bearing as a mechanism for enhancing the secondary flow in a centrifugal rotary blood pump.

    Science.gov (United States)

    Amaral, Felipe; Gross-Hardt, Sascha; Timms, Daniel; Egger, Christina; Steinseifer, Ulrich; Schmitz-Rode, Thomas

    2013-10-01

    The rapid evolution of rotary blood pump (RBP) technology in the last few decades was shaped by devices with increased durability, frequently employing magnetic or hydrodynamic suspension techniques. However, the potential for low flow in small gaps between the rotor and pump casing is still a problem for hemocompatibility. In this study, a spiral groove hydrodynamic bearing (SGB) is applied with two distinct objectives: first, as a mechanism to enhance the washout in the secondary flow path of a centrifugal RBP, lowering the exposure to high shear stresses and avoiding thrombus formation; and second, as a way to allow smaller gaps without compromising the washout, enhancing the overall pump efficiency. Computational fluid dynamics was applied and verified via bench-top experiments. An optimization of selected geometric parameters (groove angle, width and depth) focusing on the washout in the gap rather than generating suspension force was conducted. An optimized SGB geometry reduced the residence time of the cells in the gap from 31 to 27 ms, an improvement of 14% compared with the baseline geometry of 200 μm without grooves. When optimizing for pump performance, a 15% smaller gap yielded a slightly better rate of fluid exchange compared with the baseline, followed by a 22% reduction in the volumetric loss from the primary pathway. Finally, an improved washout can be achieved in a pulsatile environment due to the SGB ability to pump inwardly, even in the absence of a pressure head.

  6. NO Metabolites Levels in Human Red Blood Cells are Affected by Palytoxin, an Inhibitor of Na(+)/K(+)-ATPase Pump.

    Science.gov (United States)

    Carelli-Alinovi, Cristiana; Tellone, Ester; Russo, Anna Maria; Ficarra, Silvana; Pirolli, Davide; Galtieri, Antonio; Giardina, Bruno; Misiti, Francesco

    2014-01-01

    Palytoxin (PTX), a marine toxin, represents an increasing hazard for human health. Despite its high toxicity for biological systems, the mechanisms triggered by PTX, are not well understood. The high affinity of PTX for erythrocyte Na(+)/K(+)-ATPase pump is largely known, and it indicates PTX as a sensitive tool to characterize the signal transducer role for Na(+)/K(+)-ATPase pump. Previously, it has been reported that in red blood cells (RBC), probably via a signal transduction generated by the formation of a PTX-Na(+)/K(+)-ATPase complex, PTX alters band 3 functions and glucose metabolism. The present study addresses the question of which other signaling pathways are regulated by Na(+)/K(+)-ATPase in RBC. Here it has been evidenced that PTX following its interaction with Na(+)/K(+)-ATPase pump, alters RBC morphology and this event is correlated to decreases by 30% in nitrites and nitrates levels, known as markers of plasma membrane eNOS activity. Orthovanadate (OV), an antagonist of PTX binding to Na(+)/K(+)-ATPase pump, was able to reverse the effects elicited by PTX. Finally, current investigation firstly suggests that Na(+)/K(+)-ATPase pump, following its interaction with PTX, triggers a signal transduction involved in NO metabolism regulation.

  7. Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics.

    Science.gov (United States)

    Arvand, Arash; Hahn, Nicole; Hormes, Marcus; Akdis, Mustafa; Martin, Michael; Reul, Helmut

    2004-10-01

    A mixed-flow blood pump for long-term applications has been developed at the Helmholtz-Institute in Aachen, Germany. Central features of this implantable pump are a centrally integrated motor, a blood-immersed mechanical bearing, magnetic coupling of the impeller, and a shrouded impeller, which allows a relatively wide clearance. The aim of the study was a numerical analysis of hydraulic and hemolytic properties of different impeller design configurations. In vitro testing and numerical simulation techniques (computational fluid dynamics [CFD]) were applied to achieve a comprehensive overview. Pressure-flow charts were experimentally measured in a mock loop in order to validate the CFD data. In vitro hemolysis tests were performed at the main operating point of each impeller design. General flow patterns, pressure-flow charts, secondary flow rates, torque, and axial forces on the impeller were calculated by means of CFD. Furthermore, based on streak line techniques, shear stress (stress loading), exposure times, and volume percentage with critical stress loading have been determined. Comparison of CFD data with pressure head measurements showed excel-lent agreement. Also, impressive trend conformity was observed between in-vitro hemolysis results and numerical data. Comparison of design variations yielded clear trends and results. Design C revealed the best hydraulic and hemolytic properties and was chosen as the final design for the mixed-flow rotary blood pump.

  8. Hydraulic testing of intravascular axial flow blood pump designs with a protective cage of filaments for mechanical cavopulmonary assist.

    Science.gov (United States)

    Kapadia, Jugal Y; Pierce, Kathryn C; Poupore, Amy K; Throckmorton, Amy L

    2010-01-01

    To provide hemodynamic support to patients with a failing single ventricle, we are developing a percutaneously inserted, magnetically levitated axial flow blood pump designed to augment pressure in the cavopulmonary circulation. The device is designed to serve as a bridge-to-transplant, bridge-to-recovery, bridge-to-hemodynamic stability, or bridge-to-surgical reconstruction. This study evaluated the hydraulic performance of three blood pump prototypes (a four-bladed impeller, a three-bladed impeller, and a three-bladed impeller with a four-bladed diffuser) whose designs evolved from previous design optimization phases. Each prototype included the same geometric protective cage of filaments, which stabilize the rotor within the housing and protect the housing wall from the rotating blades. All prototypes delivered pressure rises over a range of flow rates and rotational speeds that would be sufficient to augment hemodynamic conditions in the cavopulmonary circulation. The four-bladed impeller outperformed the two remaining prototypes by >40%; this design was able to generate a pressure rise of 4-28 mm Hg for flow rates of 0.5-10 L/min at rotational speeds of 4,000-7,000 RPM. Successful development of this blood pump will provide clinicians with a feasible therapeutic option for mechanically supporting the failing Fontan.

  9. Non-invasive estimation and control of inlet pressure in an implantable rotary blood pump for heart failure patients.

    Science.gov (United States)

    Alomari, A H; Savkin, A V; Ayre, P J; Lim, E; Mason, D G; Salamonsen, R F; Fraser, J F; Lovell, N H

    2011-08-01

    We propose a dynamical model for mean inlet pressure estimation in an implantable rotary blood pump during the diastolic period. Non-invasive measurements of pump impeller rotational speed (ω), motor power (P), and pulse width modulation signal acquired from the pump controller were used as inputs to the model. The model was validated over a wide range of speed ramp studies, including (i) healthy (C1), variations in (ii) heart contractility (C2); (iii) afterload (C2, C3, C4), and (iv) preload (C5, C6, C7). Linear regression analysis between estimated and extracted mean inlet pressure obtained from in vivo animal data (greyhound dogs, N = 3) resulted in a highly significant correlation coefficients (R(2) = 0.957, 0.961, 0.958, 0.963, 0.940, 0.946, and 0.959) and mean absolute errors of (e = 1.604, 2.688, 3.667, 3.990, 2.791, 3.215, and 3.225 mmHg) during C1, C2, C3, C4, C5, C6, and C7, respectively. The proposed model was also used to design a controller to regulate mean diastolic pump inlet pressure using non-invasively measured ω and P. In the presence of model uncertainty, the controller was able to track and settle to the desired input within a finite number of sampling periods and minimal error (0.92 mmHg). The model developed herein will play a crucial role in developing a robust control system of the pump that detects and thus avoids undesired pumping states by regulating the inlet pressure within a predefined physiologically realistic limit.

  10. THEORETICAL AND EXPERIMENTAL STUDY OF THE DYNAMIC CHARACTERISTICS OF AXIAL BLOOD PUMPS

    Directory of Open Access Journals (Sweden)

    G. P. Itkin

    2011-01-01

    Full Text Available The article presents a theoretical analysis of the dynamic interaction of the left ventricle assist axial pump and the cardiovascular system. It is shown the axial pumps are working in conditions «left ventricle- aorta» generates a pulsed flow. The slope of the flow-pressure characteristics determine the amplitude of the pulsation. Data are confirmed in the chronic experiments on the biological models with the extracorporeal connection of the pump. The possibility of using this characteristic for the develope of the automatic control systems to ensure adequate operation of the pump in range of the physical activity of a patient ‘s physical activity. 

  11. Non-invasive estimation of pulsatile flow and differential pressure in an implantable rotary blood pump for heart failure patients.

    Science.gov (United States)

    AlOmari, A H; Savkin, A V; Karantonis, D M; Lim, E; Lovell, N H

    2009-04-01

    We propose dynamical models for pulsatile flow and head estimation in an implantable rotary blood pump. Pulsatile flow and head data were obtained using a circulatory mock loop where fluid solutions with different values of viscosities were used as a blood analogue with varying haematocrit (HCT). Noninvasive measurements of power and pump speed were used with HCT values as inputs to the flow model while the estimated flow was used with the speed as inputs to a head estimation model. Linear regression analysis between estimated and measured flows obtained from a mock loop resulted in a highly significant correlation (R2=0.982) and a mean absolute error (e) of 0.323 L min(-1), while for head, R2=0.933 and e=7.682 mmHg were obtained. R2=0.849 and e=0.584 L min(-1) were obtained when the same model derived in the mock loop was used for flow estimation in ex vivo porcine data (N=6). Furthermore, in the steady state, the solution of the presented flow model can be described by a previously designed and verified static model. The models developed herein will play a vital role in developing a robust control system of the pump flow coping with changing physiological demands.

  12. Real-Time Observation of Thrombus Growth Process in an Impeller of a Hydrodynamically Levitated Centrifugal Blood Pump by Near-Infrared Hyperspectral Imaging.

    Science.gov (United States)

    Sakota, Daisuke; Murashige, Tomotaka; Kosaka, Ryo; Fujiwara, Tatsuki; Nishida, Masahiro; Maruyama, Osamu

    2015-08-01

    Understanding the thrombus formation in cardiovascular devices such as rotary blood pumps is the most important issue in developing more hemocompatible devices. The objective of this study was to develop a hyperspectral imaging (HSI) method to visualize the thrombus growth process within a rotary blood pump and investigate the optical properties of the thrombus. An in vitro thrombogenic test was conducted using fresh porcine blood and a specially designed hydrodynamically levitated centrifugal blood pump with a transparent bottom. The pump rotating at 3000 rpm circulated the blood at 1.0 L/min. The bottom surface of the pump was illuminated with white light pulsed at the same frequency as the pump rotation, and the backward-scattered light was imaged using the HSI system. Using stroboscopic HSI and an image construction algorithm, dynamic spectral imaging at wavelengths ranging from 608 to 752 nm within the rotating pump was achieved. After completing the experiment, we collected the red thrombus formed in the pump impeller and quantified the thrombus hemoglobin concentration (Hbthrombus ). The spectrum changed around the center of the impeller, and the area of change expanded toward the impeller flow path. The shape corresponded approximately to the shape of the thrombus. The spectrum change indicated that the light scattering derived from red blood cells decreased. The Hbthrombus was 4.7 ± 1.3 g/dL versus a total hemoglobin of 13 ± 0.87 g/dL. The study revealed that Hbthrombus was reduced by the surrounding blood flow.

  13. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  14. A Plasmodium vivax plasmid DNA- and adenovirus-vectored malaria vaccine encoding blood stage antigens AMA1 and MSP142 in a prime/boost heterologous immunization regimen partially protects Aotus monkeys against blood stage challenge.

    Science.gov (United States)

    Obaldia, Nicanor; Stockelman, Michael G; Otero, William; Cockrill, Jennifer A; Ganeshan, Harini; Abot, Esteban N; Zhang, Jianfeng; Limbach, Keith; Charoenvit, Yupin; Doolan, Denise L; Tang, De-Chu C; Richie, Thomas L

    2017-02-08

    Malaria is caused by parasites of the genus Plasmodium that are transmitted to humans by the bites of Anopheles mosquitoes. After the elimination of P. falciparum it is predicted that Plasmodium vivax will remain an important cause of morbidity and mortality outside of Africa, stressing the importance of developing a vaccine against malaria. In this study we assess the immunogenicity and protective efficacy of two P. vivax antigens, AMA1 and MSP142 in a recombinant DNA plasmid prime/adenoviral vector (Ad) boost regimen in Aotus monkeys. Groups of 4 to 5 monkeys were immunized with DNA alone, Ad alone, prime/boost regimens of each antigen, prime/boost with both antigens, and empty vector controls, and then subjected to blood stage challenge. The heterologous immunization regimen with the antigen pair was more protective than either antigen alone or both antigens delivered with a single vaccine platform, based on their ability to induced the longest pre-patent period and time to peak parasitemia; the lowest peak and mean parasitemia; the smallest area under the parasitemia curve and the highest self-cured rate. Overall, pre-challenge MSP1 antibody titers strongly correlated with decreased parasite burden. Nevertheless, a significant proportion of immunized animals developed anemia. In conclusion, P. vivax plasmid DNA/Ad5 vaccine encoding blood stage parasite antigens AMA1 and MSP142 in a heterologous prime/boost immunization regimen, provided significant protection against blood-stage challenge in Aotus monkeys, indicating the suitability of these antigens and regimen for further development.

  15. Detection of ventricular suction in an implantable rotary blood pump using support vector machines.

    Science.gov (United States)

    Wang, Yu; Faragallah, George; Divo, Eduardo; Simaan, Marwan A

    2011-01-01

    A new suction detection algorithm for rotary Left Ventricular Assist Devices (LVAD) is presented. The algorithm is based on a Lagrangian Support Vector Machine (LSVM) model. Six suction indices are derived from the LVAD pump flow signal and form the inputs to the LSVM classifier. The LSVM classifier is trained and tested to classify pump flow patterns into three states: No Suction, Approaching Suction, and Suction. The proposed algorithm has been tested using existing in vivo data. When compared to three existing methods, the proposed algorithm produced superior performance in terms of classification accuracy, stability, and learning speed. The ability of the algorithm to detect suction provides a reliable platform in the development of a pump speed controller that has the capability of avoiding suction.

  16. Feasibility of a TinyPump system for pediatric CPB, ECMO, and circulatory assistance: hydrodynamic performances of the modified pump housing for implantable TinyPump.

    Science.gov (United States)

    Yokoyama, Naoyuki; Suzuki, Masaaki; Hoshi, Hideo; Ohuchi, Katsuhiro; Fujimoto, Tetsuo; Takatani, Setsuo

    2007-01-01

    The TinyPump is a miniature centrifugal blood pump with an extremely small priming volume of 5 ml, allowing blood transfusion free cardiopulmonary bypass as well as extracorporeal membrane oxygenation in pediatric patients. In this study, a new pump housing with the angled inlet port (25 degrees toward impeller center with respect to the flow axis) was designed to optimize the pump displaced volume and to extend the application of the TinyPump to implantable support The fluid dynamic performance analysis revealed that the head pressure losses increased from 3 to 17 mm Hg in comparison with straight port design as the pump rotational speed increased from 2,000 to 4,000 rpm. This was probably caused by perturbed flow patterns at the site of the inlet bent port area and streamline hitting the off-center of the impeller. No significant effect on pumping efficiency was observed because of modification in inlet port design. Modification in the inflow and outflow port designs together with the drive mechanism reduces the height of the pump system, including the motor, to 27 mm yielding the displaced volume of 68 ml in comparison with 40 mm of the paracorporeal system with the displaced volume of 105 ml. Further analysis in terms of hemolytic as well as antithrombogenic performance will be carried out to finalize the housing design for the implantable version of the TinyPump.

  17. A method for control of an implantable rotary blood pump for heart failure patients using noninvasive measurements.

    Science.gov (United States)

    Lim, Einly; Alomari, Abdul-Hakeem H; Savkin, Andrey V; Dokos, Socrates; Fraser, John F; Timms, Daniel L; Mason, David G; Lovell, Nigel H

    2011-08-01

    We propose a deadbeat controller for the control of pulsatile pump flow (Q(p) ) in an implantable rotary blood pump (IRBP). Noninvasive measurements of pump speed and current are used as inputs to a dynamical model of Q(p) estimation, previously developed and verified in our laboratory. The controller was tested using a lumped parameter model of the cardiovascular system (CVS), in combination with the stable dynamical models of Q(p) and differential pressure (head) estimation for the IRBP. The control algorithm was tested with both constant and sinusoidal reference Q(p) as input to the CVS model. Results showed that the controller was able to track the reference input with minimal error in the presence of model uncertainty. Furthermore, Q(p) was shown to settle to the desired reference value within a finite number of sampling periods. Our results also indicated that counterpulsation yields the minimum left ventricular stroke work, left ventricular end diastolic volume, and aortic pulse pressure, without significantly affecting mean cardiac output and aortic pressure.

  18. Properties of a monopivot centrifugal blood pump manufactured by 3D printing.

    Science.gov (United States)

    Nishida, Masahiro; Negishi, Takumi; Sakota, Daisuke; Kosaka, Ryo; Maruyama, Osamu; Hyakutake, Toru; Kuwana, Katsuyuki; Yamane, Takashi

    2016-12-01

    An impeller the same geometry as the impeller of a commercial monopivot cardiopulmonary bypass pump was manufactured using 3D printing. The 3D-printed impeller was integrated into the pump casing of the commercially available pump to form a 3D-printed pump model. The surface roughness of the impeller, the hydraulic performance, the axial displacement of the rotating impeller, and the hemolytic properties of the 3D-printed model were measured and compared with those of the commercially available model. Although the surface roughness of the 3D-printed model was significantly larger than that of the commercially available model, the hydraulic performance of the two models almost coincided. The hemolysis level of the 3D-printed model roughly coincided with that of the commercially available model under low-pressure head conditions, but increased greatly under high-pressure head conditions, as a result of the narrow gap between the rotating impeller and the pump casing. The gap became narrow under high-pressure head conditions, because the axial thrust applied to the impeller increased with increasing impeller rotational speed. Moreover, the axial displacement of the rotating impeller was twice that of the commercially available model, confirming that the elastic deformation of the 3D-printed impeller was larger than that of the commercially available impeller. These results suggest that trial models manufactured by 3D printing can reproduce the hydraulic performance of the commercial product. However, both the surface roughness and the deformation of the trial models must be considered to precisely evaluate the hemolytic properties of the model.

  19. Optimal bearing gap of a multiarc radial bearing in a hydrodynamically levitated centrifugal blood pump for the reduction of hemolysis.

    Science.gov (United States)

    Kosaka, Ryo; Yasui, Kazuya; Nishida, Masahiro; Kawaguchi, Yasuo; Maruyama, Osamu; Yamane, Takashi

    2014-09-01

    We have developed a hydrodynamically levitated centrifugal pump as a bridge-to-decision device. The purpose of the present study is to determine the optimal bearing gap of a multiarc radial bearing in the developed blood pump for the reduction of hemolysis. We prepared eight pump models having bearing gaps of 20, 30, 40, 80, 90, 100, 180, and 250 μm. The driving conditions were set to a pressure head of 200 mm Hg and a flow rate of 4 L/min. First, the orbital radius of the impeller was measured for the evaluation of the impeller stability. Second, the hemolytic property was evaluated in an in vitro hemolysis test. As a result, the orbital radius was not greater than 15 μm when the bearing gap was between 20 and 100 μm. The relative normalized index of hemolysis (NIH) ratios in comparison with BPX-80 were 37.67 (gap: 20 μm), 0.95 (gap: 30 μm), 0.96 (gap: 40 μm), 0.82 (gap: 80 μm), 0.77 (gap: 90 μm), 0.92 (gap: 100 μm), 2.76 (gap: 180 μm), and 2.78 (gap: 250 μm). The hemolysis tended to increase at bearing gaps of greater than 100 μm due to impeller instability. When the bearing gap decreased from 30 to 20 μm, the relative NIH ratios increased significantly from 0.95 to 37.67 times (P pump for the reduction of hemolysis.

  20. Implantable centrifugal blood pump with dual impeller and double pivot bearing system: electromechanical actuator, prototyping, and anatomical studies.

    Science.gov (United States)

    Bock, Eduardo; Antunes, Pedro; Leao, Tarcisio; Uebelhart, Beatriz; Fonseca, Jeison; Leme, Juliana; Utiyama, Bruno; da Silva, Cibele; Cavalheiro, Andre; Filho, Diolino Santos; Dinkhuysen, Jarbas; Biscegli, Jose; Andrade, Aron; Arruda, Celso

    2011-05-01

    An implantable centrifugal blood pump has been developed with original features for a left ventricular assist device. This pump is part of a multicenter and international study with the objective to offer simple, affordable, and reliable devices to developing countries. Previous computational fluid dynamics investigations and wear evaluation in bearing system were performed followed by prototyping and in vitro tests. In addition, previous blood tests for assessment of normalized index of hemolysis show results of 0.0054±2.46 × 10⁻³ mg/100 L. An electromechanical actuator was tested in order to define the best motor topology and controller configuration. Three different topologies of brushless direct current motor (BLDCM) were analyzed. An electronic driver was tested in different situations, and the BLDCM had its mechanical properties tested in a dynamometer. Prior to evaluation of performance during in vivo animal studies, anatomical studies were necessary to achieve the best configuration and cannulation for left ventricular assistance. The results were considered satisfactory, and the next step is to test the performance of the device in vivo.

  1. The Effects of Ambulatory Accelerations on the Stability of a Magnetically Suspended Impeller for an Implantable Blood Pump.

    Science.gov (United States)

    Paul, Gordon; Rezaienia, Mohammed Amin; Rahideh, Akbar; Munjiza, Ante; Korakianitis, Theodosios

    2016-09-01

    This article describes the effects of ambulatory accelerations on the stability of a magnetically suspended impeller for use in implantable blood pumps. A magnetic suspension system is developed to control the radial position of a magnetic impeller using coils in the pump casing. The magnitude and periodicity of ambulatory accelerations at the torso are measured. A test rig is then designed to apply appropriate accelerations to the suspension system. Accelerations from 0 to 1 g are applied to the suspended impeller with ambulatory periodicity while the radial position of the impeller and power consumption of the suspension system are monitored. The test is carried out with the impeller suspended in air, water, and a glycerol solution to simulate the viscosity of blood. A model is developed to investigate the effects of the radial magnetic suspension system and fluid damping during ambulatory accelerations. The suspension system reduces the average displacement of the impeller suspended in aqueous solutions within its casing to 100 µm with a power consumption of below 2 W during higher magnitude ambulatory accelerations (RMS magnitude 0.3 g). The damping effect of the fluid is also examined and it is shown that buoyancy, rather than drag, is the primary cause of the damping at the low displacement oscillations that occur during the application of ambulatory accelerations to such a suspension system.

  2. Estimation of the radial force using a disturbance force observer for a magnetically levitated centrifugal blood pump.

    Science.gov (United States)

    Pai, C N; Shinshi, T; Shimokohbe, A

    2010-01-01

    Evaluation of the hydraulic forces in a magnetically levitated (maglev) centrifugal blood pump is important from the point of view of the magnetic bearing design. Direct measurement is difficult due to the absence of a rotor shaft, and computational fluid dynamic analysis demands considerable computational resource and time. To solve this problem, disturbance force observers were developed, using the radial controlled magnetic bearing of a centrifugal blood pump, to estimate the radial forces on the maglev impeller. In order to design the disturbance observer, the radial dynamic characteristics of a maglev impeller were evaluated under different working conditions. It was observed that the working fluid affects the additional mass and damping, while the rotational speed affects the damping and stiffness of the maglev system. Based on these results, disturbance force observers were designed and implemented. The designed disturbance force observers present a bandwidth of 45 Hz. In non-pulsatile conditions, the magnitude of the estimated radial thrust increases in proportion to the flowrate, and the rotational speed has little effect on the force direction. At 5 l/min against 100 mmHg, the estimated radial thrust is 0.95 N. In pulsatile conditions, this method was capable of estimating the pulsatile radial thrust with good response.

  3. 国产轴流血泵的血液相容性特征:验证性观察%Blood compatibility of an axial-flow blood pump made in China:Verifying observation

    Institute of Scientific and Technical Information of China (English)

    蔺嫦燕; 吴广辉; 李冰一; 侯晓彤; 王景; 周响乐; 潘红九

    2007-01-01

    BACKGROUND: Axial-flow blood pump is a main pump for ventricle assistance. Previous researches demonstrate that poor hemocompatibility of blood pump is an important factor for hemolysis and thrombus.OBJ ECTTVE: To design an axial-flow blood pump based on previous kinds of blood pumps through changing whole appearance and impeller shape of the pump by using Computer-Aided Design CAD) and Computational Fluid Dynamics (CFD), and manufacture it successfully.DESIGN: Rationality of theoretical design was verified by practical tests.SETTTNG: Beijing Anzhen Hospital of Capital University of Medical Sciences Department of Biomedical Engineering,Beijing Institute of Heart, lung and Blood Vessel Diseases; the Faurteenth Institute of China-Aerospace Science and Industry Corporation.MATERIALS: Body of blood pump and impeller were titanium alligation, and shaft bearing was ceramic. Test in vitro was accorded to artificial ventricular assist device which was provided by Department of Biomedical Engineering, Beijing Anzhen Hospital of Capital University of Medical Sciences. Experimental goats were provided by Experimental Animal Center, Beijing Anzhen Hospital of Capital University of Medical Sciences.METHODS: Since the beginning of 2005, a model of axial flow blood pump was designed in the 14th Institute of China-Aerospace Science and Industry Corporation base on decreasing shearing force and circulating dead bands. In the process, CAD and CFD were used to generate the geometrical data document of pump's structure, which included the figures of pump's body, shape and number of impeller's vanes, the structure and position of the guide vanes, and the size of impeller's screw-pitch. And then, NC machine tool was used for shaping. Finally, axial-flow blood pump was fixed on artificial ventricular assist device which was provided by Department of Biomedical Engineering, Beijing Anzhen Hospital of Capital University of Medical Sciences. The pump's hemodynamic output was 5 L/min and the

  4. The CentriMag centrifugal blood pump as a benchmark for in vitro testing of hemocompatibility in implantable ventricular assist devices.

    Science.gov (United States)

    Chan, Chris H H; Pieper, Ina Laura; Hambly, Rebecca; Radley, Gemma; Jones, Alyssa; Friedmann, Yasmin; Hawkins, Karl M; Westaby, Stephen; Foster, Graham; Thornton, Catherine A

    2015-02-01

    Implantable ventricular assist devices (VADs) have proven efficient in advanced heart failure patients as a bridge-to-transplant or destination therapy. However, VAD usage often leads to infection, bleeding, and thrombosis, side effects attributable to the damage to blood cells and plasma proteins. Measuring hemolysis alone does not provide sufficient information to understand total blood damage, and research exploring the impact of currently available pumps on a wider range of blood cell types and plasma proteins such as von Willebrand factor (vWF) is required to further our understanding of safer pump design. The extracorporeal CentriMag (Thoratec Corporation, Pleasanton, CA, USA) has a hemolysis profile within published standards of normalized index of hemolysis levels of less than 0.01 g/100 L at 100 mm Hg but the effect on leukocytes, vWF multimers, and platelets is unknown. Here, the CentriMag was tested using bovine blood (n = 15) under constant hemodynamic conditions in comparison with a static control for total blood cell counts, hemolysis, leukocyte death, vWF multimers, microparticles, platelet activation, and apoptosis. The CentriMag decreased the levels of healthy leukocytes (P pump which could be used as a standard in blood damage assays to inform the design of new implantable blood pumps.

  5. Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yambe, Tomoyuki; Imachi, Kou; Yamane, Takashi

    2013-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump with a semi-open impeller for long-term circulatory assist. The pump uses hydrodynamic bearings to enhance durability and reliability without additional displacement-sensors or control circuits. However, a narrow bearing gap of the pump has a potential for hemolysis. The purpose of this study is to develop the hydrodynamically levitated centrifugal blood pump with a semi-open impeller, and to evaluate the effect of a bearing gap on hemolytic property. The impeller levitates using a spiral-groove type thrust bearing, and a herringbone-groove type radial bearing. The pump design was improved by adopting a step type thrust bearing and optimizing the pull-up magnetic force. The pump performance was evaluated by a levitation performance test, a hemolysis test and an animal experiment. In these tests, the bearing gap increased from 1 to 63 μm. In addition, the normalized index of hemolysis (NIH) improved from 0.415 to 0.005 g/100 l, corresponding to the expansion of the bearing gap. In the animal experiment for 24 h, the plasma-free hemoglobin remained within normal ranges (pump was improved to the acceptable level by expanding the bearing gap greater than 60 μm.

  6. Organ hierarchy during low blood flow on-pump: a randomized experimental positron emission tomography study

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Kjærgaard, Benedict; Frøkiær, Jørgen

    ].The purpose of this animal study is to investigate the organ hierarchy of brain, liver, kidney and muscle at normal and low blood flows by using dynamic positron tomography (PET-CT) during CPB. Methods CPB at different blood flows will be investigated in an experimental model of six 70 kg pigs...

  7. Development of a disposable magnetically levitated centrifugal blood pump (MedTech Dispo) intended for bridge-to-bridge applications--two-week in vivo evaluation.

    Science.gov (United States)

    Nagaoka, Eiki; Someya, Takeshi; Kitao, Takashi; Kimura, Taro; Ushiyama, Tomohiro; Hijikata, Wataru; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2010-09-01

    Last year, we reported in vitro pump performance, low hemolytic characteristics, and initial in vivo evaluation of a disposable, magnetically levitated centrifugal blood pump, MedTech Dispo. As the first phase of the two-stage in vivo studies, in this study we have carried out a 2-week in vivo evaluation in calves. Male Holstein calves with body weight of 62.4–92.2 kg were used. Under general anesthesia, a left heart bypass with a MedTech Dispo pump was instituted between the left atrium and the descending aorta via left thoracotomy. Blood-contacting surface of the pump was coated with a 2-methacryloyloxyethyl phosphorylcholine polymer. Post-operatively, with activated clotting time controlled at 180–220 s using heparin and bypass flow rate maintained at 50 mL/kg/min, plasma-free hemoglobin (Hb), coagulation, and major organ functions were analyzed for evaluation of biocompatibility. The animals were electively sacrificed at the completion of the 2-week study to evaluate presence of thrombus inside the pump,together with an examination of major organs. To date, we have done 13 MedTech Dispo implantations, of which three went successfully for a 2-week duration. In these three cases, the pump produced a fairly constant flow of 50 mL/Kg/min. Neurological disorders and any symptoms of thromboembolism were not seen. Levels of plasma-free Hb were maintained very low. Major organ functions remained within normal ranges. Autopsy results revealed no thrombus formation inside the pump. In the last six cases, calves suffered from severe pneumonia and they were excluded from the analysis. The MedTech Dispo pump demonstrated sufficient pump performance and biocompatibility to meet requirements for 1-week circulatory support. The second phase (2-month in vivo study) is under way to prove the safety and efficacy of MedTech Dispo for 1-month applications.

  8. Study on Driving Performance of the Axial-Flow Blood Pump under the Condition of Large Gap

    Directory of Open Access Journals (Sweden)

    Yan Xu

    2017-01-01

    Full Text Available The paper demonstrates an improvement of the simulation and computational methods for research on the system magnetic field and driving performance of the large gap magnetic drive system, which is used to drive the axial flow blood pump. The operational principle and structure of large gap magnetic drive system are narrated. Ansoft is adopted to simulate a three-dimensional driving torque to improve accuracy of computation. Experiments and theoretical study show that the use of Z10-T25 oriented silicon steel sheets as the electromagnetic core material can remarkably improve the system driving performance as well as optimize the volume and weight of the electromagnets. So the electromagnet made with oriented silicon steel sheets is conducive to improving the driving performance.

  9. Organ hierarchy during low blood flow on-pump: a randomized experimental positron emission tomography study

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Kjærgaard, Benedict; Frøkiær, Jørgen;

    ; normothermic CPB with a blood flow of 2.5 L/min/m2 for one hour followed by a randomisation to a blood flow of either 2.0 L/min/m2 (Group I) or 1.5 L/min/m2 (Group II) for another hour and finally one hour with blood flow of 2.5 L/min/m2. Regional tissue perfusion of brain, liver, kidney, and muscle...... indicates existence of an organ hierarchy with persevered perfusion of the brain but affected muscle tissue perfusion in in both Groups of suboptimal blood flow. The finally results will be ready for presentation at DASAIM 2014 in November. Non-parametric statistical method will be used. Discussion To our...... knowledge this is the first study investigating organ hierarchy with dynamic PET-CT during profound systemic ischemia due to suboptimal blood flows during normothermic CPB. References 1. Murphy JM, Hessel II EA, Groom RC. Optimal perfusion during cardiopulmonary bypass: an Evidence-based approach. Anesth...

  10. Development of a disposable maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation.

    Science.gov (United States)

    Someya, Takeshi; Kobayashi, Mariko; Waguri, Satoshi; Ushiyama, Tomohiro; Nagaoka, Eiki; Hijikata, Wataru; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2009-09-01

    MedTech Dispo, a disposable maglev centrifugal blood pump with two degrees of freedom magnetic suspension and radial magnetic coupling rotation, has been developed for 1-month extracorporeal circulatory support. As the first stage of a two-stage in vivo evaluation, 2-week evaluation of a prototype MedTech Dispo was conducted. In in vitro study, the pump could produce 5 L/min against 800 mm Hg and the normalized index of hemolysis was 0.0054 +/- 0.0008 g/100 L. In in vivo study, the pump, with its blood-contacting surface coated with biocompatible 2-methacryloyloxyethyl phosphorylcholine polymer, was implanted in seven calves in left heart bypass. Pump performance was stable with a mean flow of 4.49 +/- 0.38 L/min at a mean speed of 2072.1 +/- 64.5 rpm. The maglev control revealed its stability in rotor position during normal activity by the calves. During 2 weeks of operation in two calves which survived the intended study period, no thrombus formation was seen inside the pump and levels of plasma free hemoglobin were maintained below 4 mg/dL. Although further experiments are required, the pump demonstrated the potential for sufficient and reliable performance and biocompatibility in meeting the requirements for cardiopulmonary bypass and 1-week circulatory support.

  11. Evaluation of a Spiral Groove Geometry for Improvement of Hemolysis Level in a Hydrodynamically Levitated Centrifugal Blood Pump.

    Science.gov (United States)

    Murashige, Tomotaka; Kosaka, Ryo; Sakota, Daisuke; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2015-08-01

    The purpose of this study is to evaluate a spiral groove geometry for a thrust bearing to improve the hemolysis level in a hydrodynamically levitated centrifugal blood pump. We compared three geometric models: (i) the groove width is the same as the ridge width at any given polar coordinate (conventional model); (ii) the groove width contracts inward from 9.7 to 0.5 mm (contraction model); and (iii) the groove width expands inward from 0.5 to 4.2 mm (expansion model). To evaluate the hemolysis level, an impeller levitation performance test and in vitro hemolysis test were conducted using a mock circulation loop. In these tests, the driving conditions were set at a pressure head of 200 mm Hg and a flow rate of 4.0 L/min. As a result of the impeller levitation performance test, the bottom bearing gaps of the contraction and conventional models were 88 and 25 μm, respectively. The impeller of the expansion model touched the bottom housing. In the hemolysis test, the relative normalized index of hemolysis (NIH) ratios of the contraction model in comparison with BPX-80 and HPM-15 were 0.6 and 0.9, respectively. In contrast, the relative NIH ratios of the conventional model in comparison with BPX-80 and HPM-15 were 9.6 and 13.7, respectively. We confirmed that the contraction model achieved a large bearing gap and improved the hemolysis level in a hydrodynamically levitated centrifugal blood pump.

  12. Identification of cytoskeletal elements enclosing the ATP pools that fuel human red blood cell membrane cation pumps.

    Science.gov (United States)

    Chu, Haiyan; Puchulu-Campanella, Estela; Galan, Jacob A; Tao, W Andy; Low, Philip S; Hoffman, Joseph F

    2012-07-31

    The type of metabolic compartmentalization that occurs in red blood cells differs from the types that exist in most eukaryotic cells, such as intracellular organelles. In red blood cells (ghosts), ATP is sequestered within the cytoskeletal-membrane complex. These pools of ATP are known to directly fuel both the Na(+)/K(+) and Ca(2+) pumps. ATP can be entrapped within these pools either by incubation with bulk ATP or by operation of the phosphoglycerate kinase and pyruvate kinase reactions to enzymatically generate ATP. When the pool is filled with nascent ATP, metabolic labeling of the Na(+)/K(+) or Ca(2+) pump phosphoproteins (E(Na)-P and E(Ca)-P, respectively) from bulk [γ-(32)P]-ATP is prevented until the pool is emptied by various means. Importantly, the pool also can be filled with the fluorescent ATP analog trinitrophenol ATP, as well as with a photoactivatable ATP analog, 8-azido-ATP (N(3)-ATP). Using the fluorescent ATP, we show that ATP accumulates and then disappears from the membrane as the ATP pools are filled and subsequently emptied, respectively. By loading N(3)-ATP into the membrane pool, we demonstrate that membrane proteins that contribute to the pool's architecture can be photolabeled. With the aid of an antibody to N(3)-ATP, we identify these labeled proteins by immunoblotting and characterize their derived peptides by mass spectrometry. These analyses show that the specific peptides that corral the entrapped ATP derive from sequences within β-spectrin, ankyrin, band 3, and GAPDH.

  13. 46 CFR 181.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire pumps. 181.300 Section 181.300 Shipping COAST GUARD... EQUIPMENT Fire Main System § 181.300 Fire pumps. (a) A self priming, power driven fire pump must be..., the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of...

  14. 46 CFR 118.300 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 118.300 Section 118.300 Shipping COAST GUARD... Fire pumps. (a) A self priming, power driven fire pump must be installed on each vessel. (b) On a..., the fire pump must be capable of delivering a single hose stream from the highest hydrant, through...

  15. Preload-based starling-like control for rotary blood pumps: numerical comparison with pulsatility control and constant speed operation.

    Directory of Open Access Journals (Sweden)

    Mahdi Mansouri

    Full Text Available In this study, we evaluate a preload-based Starling-like controller for implantable rotary blood pumps (IRBPs using left ventricular end-diastolic pressure (PLVED as the feedback variable. Simulations are conducted using a validated mathematical model. The controller emulates the response of the natural left ventricle (LV to changes in PLVED. We report the performance of the preload-based Starling-like controller in comparison with our recently designed pulsatility controller and constant speed operation. In handling the transition from a baseline state to test states, which include vigorous exercise, blood loss and a major reduction in the LV contractility (LVC, the preload controller outperformed pulsatility control and constant speed operation in all three test scenarios. In exercise, preload-control achieved an increase of 54% in mean pump flow ([Formula: see text] with minimum loading on the LV, while pulsatility control achieved only a 5% increase in flow and a decrease in mean pump speed. In a hemorrhage scenario, the preload control maintained the greatest safety margin against LV suction. PLVED for the preload controller was 4.9 mmHg, compared with 0.4 mmHg for the pulsatility controller and 0.2 mmHg for the constant speed mode. This was associated with an adequate mean arterial pressure (MAP of 84 mmHg. In transition to low LVC, [Formula: see text] for preload control remained constant at 5.22 L/min with a PLVED of 8.0 mmHg. With regards to pulsatility control, [Formula: see text] fell to the nonviable level of 2.4 L/min with an associated PLVED of 16 mmHg and a MAP of 55 mmHg. Consequently, pulsatility control was deemed inferior to constant speed mode with a PLVED of 11 mmHg and a [Formula: see text] of 5.13 L/min in low LVC scenario. We conclude that pulsatility control imposes a danger to the patient in the severely reduced LVC scenario, which can be overcome by using a preload-based Starling-like control approach.

  16. New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves.

    Science.gov (United States)

    Fujiwara, Tatsuki; Nagaoka, Eiki; Watanabe, Taiju; Miyagi, Naoto; Kitao, Takashi; Sakota, Daisuke; Mamiya, Taichi; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2013-05-01

    We have evaluated the feasibility of a newly developed single-use, magnetically levitated centrifugal blood pump, MedTech Mag-Lev, in a 3-week extracorporeal membrane oxygenation (ECMO) study in calves against a Medtronic Bio-Pump BPX-80. A heparin- and silicone-coated polypropylene membrane oxygenator MERA NHP Excelung NSH-R was employed as an oxygenator. Six healthy male Holstein calves with body weights of about 100 kg were divided into two groups, four in the MedTech group and two in the Bio-Pump group. Under general anesthesia, the blood pump and oxygenator were inserted extracorporeally between the main pulmonary artery and the descending aorta via a fifth left thoracotomy. Postoperatively, both the pump and oxygen flow rates were controlled at 3 L/min. Heparin was continuously infused to maintain the activated clotting time at 200-240 s. All the MedTech ECMO calves completed the study duration. However, the Bio-Pump ECMO calves were terminated on postoperative days 7 and 10 because of severe hemolysis and thrombus formation. At the start of the MedTech ECMO, the pressure drop across the oxygenator was about 25 mm Hg with the pump operated at 2800 rpm and delivering 3 L/min flow. The PO2 of the oxygenator outlet was higher than 400 mm Hg with the PCO2 below 45 mm Hg. Hemolysis and thrombus were not seen in the MedTech ECMO circuits (plasma-free hemoglobin [PFH] 20 mg/dL) and large thrombus were observed in the Bio-Pump ECMO circuits. Plasma leakage from the oxygenator did not occur in any ECMO circuits. Three-week cardiopulmonary support was performed successfully with the MedTech ECMO without circuit exchanges. The MedTech Mag-Lev could help extend the durability of ECMO circuits by the improved biocompatible performances.

  17. Prime Slaughter

    DEFF Research Database (Denmark)

    Valente, Andrea; Marchetti, Emanuela

    2011-01-01

    Starting from the difficulty of creating playful representation of domain-specific abstract concepts, this study discusses the design of Prime Slaughter, a computer game aimed at facilitating individual sense-making of abstract mathematical concepts. Specifically the game proposes a transposition...... of primality and factorization into playful interactions, addressed to primary and early secondary school children. Taking into account individual needs expressed by children regarding play, during a participatory design processes aimed at enhancing learning in museums, Prime Slaughter allows for multiple...

  18. Prime Slaughter

    DEFF Research Database (Denmark)

    Valente, Andrea; Marchetti, Emanuela

    2011-01-01

    Starting from the difficulty of creating playful representation of domain-specific abstract concepts, this study discusses the design of Prime Slaughter, a computer game aimed at facilitating individual sense-making of abstract mathematical concepts. Specifically the game proposes a transposition...... of primality and factorization into playful interactions, addressed to primary and early secondary school children. Taking into account individual needs expressed by children regarding play, during a participatory design processes aimed at enhancing learning in museums, Prime Slaughter allows for multiple...

  19. Optically pumped laser lines of Na2 pumped by Kr/+/ /6471 A/ and HeNe /6328 A/ lasers - Identification of old lines and prediction of possible new lines

    Science.gov (United States)

    Verma, K. K.; Stwalley, W. C.; Zemke, W. T.

    1981-01-01

    The laser emission lines of a sodium dimer laser pumped by Kr(+) and HeNe lasers at wavelengths of 6471 and 6328 A, respectively, are identified. The Na2 fluorescence was excited in a crossed heat pipe oven at a sodium pressure of about 1 torr, and recorded spectra were compared with transition probability calculations. For the 6471-A pump, three series excited by absorption through the transitions v-prime = 13, J-prime = 35 - v-double prime = 4, J-double prime = 34; v-prime = 13, J-prime = 83 - v-double-prime = 2, J-double prime = 84 and v-prime = 20, J-prime = 98 - v-double prime = 6, J-double prime = 99 are observed in the region 6100-8350 A. At 6328 A, series excited through the transitions v-prime = 14, J-prime = 45 - v-double prime = 2, J-double prime = 46; v-prime = 16, J-prime = 17 - v-double prime = 4, J-double prime = 18; v-prime = 22, J-prime = 86 - v-double prime = 6, J-double prime = 85 and v-prime = 25, J-prime = 87 - v-double prime = 8, J-double prime = 86. Most of the previously observed optically pumped lines are found to correspond to the three level laser system. Additional wavelengths expected to undergo lasing under slightly improved conditions are also identified.

  20. Hydraulic design of a double suction blood pump%一种双吸式血液泵水力设计

    Institute of Scientific and Technical Information of China (English)

    田爱民; 庄保堂; 朱雷; 罗先武; 许洪元

    2011-01-01

    The flow in pumps for open-heart and artificial heart units must be carefully optimized for the blood flow.The steady state three-dimensional turbulent flow inside a double suction blood pump was analyzed by solving the RANS equations with the SST k-ω turbulence model.The flow features in the blood pump were analyzed to optimize the design of the hydraulic components including the impeller and volute casing and the effects of various designs on the pump operating.The flow passage near the casing tongue has larger local wall shear stresses that may damage the blood cells,damage in the pump.The pump hydraulic efficiency can be improved by increasing the volute casing section area and a larger impeller vane exit angle will increase the pump head.Flow separation and its effect on pump performance can be controlled by a radial bladed impeller with a vane exit angle of 90°.The wall shear stresses for all designs were 20~26 Pa,less than the critical value for blood cell damage.%为了更好地满足体外循环装置和人工心脏的运行要求,该文采用RANS方法和SSTk-ω湍流模型对一种双吸式血液泵进行了三维定常湍流计算;在详细分析血液泵内部流动特征的基础上,对泵的水力部件如叶轮及压水室进行了设计优化,并探讨了各种设计对血液泵主要运行参数的影响。结果表明:压水室隔舌附近的流道容易出现较大的局部壁面剪切应力,是泵内血细胞容易受到损伤的危险区域;适当增大压水室断面面积有利于提高泵的水力效率;选择较大的叶片出口安放角时血液泵可获得较高的扬程,但采用径向叶片叶轮(出口叶片安放角为90°)时须设法控制流

  1. Effect of Impeller Geometry on Lift-Off Characteristics and Rotational Attitude in a Monopivot Centrifugal Blood Pump.

    Science.gov (United States)

    Nishida, Masahiro; Nakayama, Kento; Sakota, Daisuke; Kosaka, Ryo; Maruyama, Osamu; Kawaguchi, Yasuo; Kuwana, Katsuyuki; Yamane, Takashi

    2016-06-01

    The effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis. Next, the lift-off point and the tilt of the rotational axis of the impeller were measured experimentally. The CFD analysis showed that the axial thrust increased gently in the FR and R models as the flow rate increased, whereas it increased drastically in the F and N models. This difference in axial thrust was likely from the higher pressure caused by the smaller circumferential velocity in the gap between the top surface of the impeller and the casing in the FR and R models than in the F and N models, which was caused by the rear cutout. These results corresponded with the experimental results showing that the impellers lifted off in the F and N models as the flow rate increased, whereas it did not in the FR and R models. Conversely, the movement about the pivot point increased in the direction opposite the side with the pump outlet as the flow rate increased. However, the tilt of the rotational axis of the impeller, which oriented away from the pump outlet, was less than 0.8° in any model under any conditions, and was considered to negligibly affect the rotational attitude of the impeller. These results confirm that a rear cutout prevents lift-off of the impeller caused by a decrease in the axial thrust.

  2. Jet pump assisted arterial heat pipe

    Science.gov (United States)

    Bienert, W. B.; Ducao, A. S.; Trimmer, D. S.

    1978-01-01

    This paper discusses the concept of an arterial heat pipe with a capillary driven jet pump. The jet pump generates a suction which pumps vapor and noncondensible gas from the artery. The suction also forces liquid into the artery and maintains it in a primed condition. A theoretical model was developed which predicts the existence of two stable ranges. Up to a certain tilt the artery will prime by itself once a heat load is applied to the heat pipe. At higher tilts, the jet pump can maintain the artery in a primed condition but self-priming is not possible. A prototype heat pipe was tested which self-primed up to a tilt of 1.9 cm, with a heat load of 500 watts. The heat pipe continued to prime reliably when operated as a VCHP, i.e., after a large amount of noncondensible gas was introduced.

  3. In-vitro assessment of centrifugal pumps for ventricular assist.

    Science.gov (United States)

    Jakob, H; Kutschera, Y; Palzer, B; Prellwitz, W; Oelert, H

    1990-08-01

    Currently two major types of centrifugal pumps are commercially available for ventricular assist: the Biomedicus-cone (Group I) and the Centrimed-impeller pump (now Sarns 3M) (Group II). To compare them for blood trauma and hemolysis, an in-vitro experiment was designed with a Stöckert roller pump as a standard control (Group III). The in-vitro circuit was constructed consisting of a pump head, electromagnetic flow probe, polyvinyl chloride tubing and a reservoir, identical for all groups. Human ACD blood was used for priming and was circulated with a flow rate of 2 L/min for 24 h. Blood samples were taken at 0, 1, 3, 6, 12, and 24 h and zero control values were subtracted from the resulting data per time interval. Among the 16 parameters studied, a highly significant difference in favor of Group I was found for glutamate oxalacetate transaminase (GOT) and lactate dehydrogenase (p less than 0.0001) and for the free plasma hemoglobin (p less than 0.0001) after 12 and 24 h, respectively. The hemolytic index (Allen) again was lowest for group I in contrast to Groups II and III (0.012 versus 0.060 and 1.70) after 24 h. All other parameters studied did not render significant differences between the systems tested. The authors conclude that the Biomedicus pump currently is the least traumatic centrifugal pump for ventricular assist.

  4. Patient condition affects the collection of peripheral blood progenitors after priming with recombinant granulocyte colony-stimulating factor.

    Science.gov (United States)

    Chabannon, C; Le Coroller, A G; Faucher, C; Novakovitch, G; Blaise, D; Moatti, J P; Maraninchi, D; Mannoni, P

    1995-06-01

    A total of 258 aphereses were performed in 79 patients with nonmyeloid malignancies after mobilization of peripheral blood stem cells (PBSC) with recombinant human granulocyte colony-stimulating factor (rhG-CSF). Apheresis products were examined for viable mononuclear cell (VMC), CD34+ cell, and clonogenic cell contents. The number of progenitors in aphereses differs in subgroups of patients with different diagnoses. However, the number of CD34+ or clonogenic cells is dependent on age and amount of chemotherapy delivered to patients before collection rather than on the nature of the disease itself. In addition, the actual dose of rhG-CSF used to mobilize PBSC and the number of VMC in aphereses influenced the clonogenicity of CD34+ cells, although the daily dose of rhG-CSF seems to play little role on the number of clonogenic cells in each individual apheresis product. CD34+ cell and CFU-C (or CFU-GM) numbers are related parameters, and the relation can be described as linear. However, the linear relation varies in different patient groups, and most of the linearity is induced by the highest sets of values. We conclude that mobilization with low doses of rhG-CSF alone is feasible and that the probability of collecting a high number of peripheral blood progenitors is increased in young patients undergoing apheresis early in the course of the disease. Although the relationship between CD34+ cells and CFUs can be described as linear in well-defined situations, its relevance may be limited because it is not a universal finding.

  5. Design and Evaluation of a Fully Implantable Control Unit for Blood Pumps

    Directory of Open Access Journals (Sweden)

    Kristin Unthan

    2015-01-01

    Full Text Available As the number of donor hearts is limited while more and more patients suffer from end stage biventricular heart failure, Total Artificial Hearts become a promising alternative to conventional treatment. While pneumatic devices sufficiently supply the patients with blood flow, the patient’s quality of life is limited by the percutaneous pressure lines and the size of the external control unit. This paper describes the development of the control unit of the ReinHeart, a fully implantable Total Artificial Heart. General requirements for any implantable control unit are defined from a technical and medical point of view: necessity of a Transcutaneous Energy Transmission, autonomous operation, safety, geometry, and efficiency. Based on the requirements, a prototype is designed; it incorporates a LiFePo4 battery pack with charger, a rectifier for transcutaneous energy transmission, the motor’s driver electronics, and a microcontroller which monitors and controls all functions. In validation tests, the control unit demonstrated a stable operation on TET and battery supply and a safe switching from one supply to the other. The overall mean efficiency is 14% on TET and 22% on battery supply. The control unit is suitable for chronic animal trials of the ReinHeart.

  6. "空心转子"血泵的技术发展及初步结果%Technical development and initial tests of a " hollow-rotor" blood pump

    Institute of Scientific and Technical Information of China (English)

    D.Baykut; S.Fabbri; M.Jeker; R.Pfluger; T.Ruppli; E.Schkommodau

    2010-01-01

    @@ Background: Ventricular assist devices are lifesaving for patients with end-stage heart failure who have no other options to survive until heart transplantation.The majority of new-generation devices are fully implantable blood pumps with axial or centrifugal flow directions.Current axial-flow blood pumps contain a conveying spiral for blood transport with a central rotating body and have very suitable dimensions for implantation.

  7. Negative association of donor age with CD34+ cell dose in mixture allografts of G-CSF-primed bone marrow and G-CSF-mobilized peripheral blood harvests

    Institute of Scientific and Technical Information of China (English)

    Li Yan; Chang Yingjun; Xu Lanping; Zhang Xiaohui; Huang Xiaojun

    2014-01-01

    Background The effects of donor characteristics on CD34+ cell dose remain controversial.Recently,we developed a novel haploidentical transplant protocol,in which mixture allografts of granulocyte colony-stimulating factor (G-CSF)-primed bone marrow (G-BM) and G-CSF-mobilized peripheral blood (G-PB) were used.The aim of this study was to investigate the effects of donor characteristics on CD34+ cell dose in mixture allografts of G-BM and G-PB.Methods A total of 162 healthy adult donors,who underwent bone marrow harvest and peripheral blood collection between January 2009 and November 2010 in Peking University People's Hospital,were prospectively investigated.G-CSF was administered subcutaneously at a dose of 5 μg/kg once a day for 5-6 consecutive days.Bone marrow and peripheral blood stem cells were harvested on the fourth day and fifth day,respectively.A final total CD34+ cell dose less than 2× 106 cells/kg recipient body weight was considered a poor mobilization.Results Of the 162 donors,31 (19.1%) did not attain this threshold.The obtained median CD34+ cell doses in bone marrow,peripheral blood,and mixture allografts were 0.83×106/kg,2.40×106/kg,and 3.47×106/kg,respectively.Multiple regression analysis showed that donor age had a significant negative effect on CD34+ cell dose in either G-BM,or G-PB,or mixture allografts of G-BM and G-PB.And a 1-year increase in age was associated with a 5.6% decrease in the odds of achieving mobilization cutoff.No significant correlation was found for donor gender,body mass index (BMI),and weight.Conclusion Donor age is the only factor among the four parameters,including age,gender,weight,and BMI,that influence CD34+ cell dose in mixture allografts of G-BM and G-PB,and younger donors should be chosen to obtain sufficient CD34+ cells for transplantation.

  8. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature.

    Science.gov (United States)

    Wilson, Ana Maria Miranda Martins; Peterlini, Maria Angélica Sorgini; Pedreira, Mavilde da Luz Gonçalves

    2016-08-15

    to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells) and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies. identificar na literatura a produção científica acerca dos efeitos de bomba de infusão na administração de hemácias e avaliar as implicações do uso desses equipamentos na prática transfusional de enfermagem. revisão integrativa de literatura nas bases de dados Pubmed/Medline, Scopus, Biblioteca Virtual em Saúde, SciELO, Web of Science e Cochrane, utilizando os descritores "bombas de infusão", "transfusão de sangue", "transfusão de eritrócitos" e "hemólise". A data inicial não foi delimitada e a final foi dezembro de

  9. 轴流式血泵流体特性 CFD 研究%Research on fluid properties of the anxial flow blood pump based on CFD

    Institute of Scientific and Technical Information of China (English)

    谢雄; 谭建平; 刘云龙

    2014-01-01

    在轴流式血泵的研发中,通常将血液当作牛顿流体来处理,考虑到当动脉存在局部狭窄等几何突变情况时,动脉局部流场中可能产生流动剪切率非常低的区域,因此有必要考虑血液的非牛顿特性。建立了轴流式血泵模型,通过C FD仿真分析得到血泵转速和流量的变化对血泵出入口流场的影响,以及血泵导叶对泵体内流场的影响规律,并通过对设计的血泵进行泵水实验,测量了轴流式血泵输出流量和压力参数。结果表明所设计的血泵在驱动性能上和仿真是相符的。%In the development of the axial flow blood pump ,the blood was usually taken as a New-tonian fluid .When taking into account of the existence of local artery stenosis and other geomet-ric mutation occurs ,an area with very low flow shear rate meight be produced in the arterial par-tial flow field .So the non-New tonian characteristics of blood should be considered .A model of the axial flow blood pump was established ,and the impaction of the flow and the rotate speed on the inlet and outlet of the flow field in the blood pump was analyzed through CFD as well as the influence of the guide vane on the flow field .By the drive experiment of the designed blood pump ,the output flow and pressure were measured .The results showed that the designed blood pump was consistent on the drive performance of the simulation .

  10. Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis.

    Science.gov (United States)

    Masuzawa, Toru; Ohta, Akiko; Tanaka, Nobuatu; Qian, Yi; Tsukiya, Tomonori

    2009-01-01

    The effect of the hydraulic force on magnetically levitated (maglev) pumps should be studied carefully to improve the suspension performance and the reliability of the pumps. A maglev centrifugal pump, developed at Ibaraki University, was modeled with 926 376 hexahedral elements for computational fluid dynamics (CFD) analyses. The pump has a fully open six-vane impeller with a diameter of 72.5 mm. A self-bearing motor suspends the impeller in the radial direction. The maximum pressure head and flow rate were 250 mmHg and 14 l/min, respectively. First, a steady-state analysis was performed using commercial code STAR-CD to confirm the model's suitability by comparing the results with the real pump performance. Second, transient analysis was performed to estimate the hydraulic force on the levitated impeller. The impeller was rotated in steps of 1 degrees using a sliding mesh. The force around the impeller was integrated at every step. The transient analysis revealed that the direction of the radial force changed dynamically as the vane's position changed relative to the outlet port during one circulation, and the magnitude of this force was about 1 N. The current maglev pump has sufficient performance to counteract this hydraulic force. Transient CFD analysis is not only useful for observing dynamic flow conditions in a centrifugal pump but is also effective for obtaining information about the levitation dynamics of a maglev pump.

  11. Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study

    DEFF Research Database (Denmark)

    Brassard, Patrice; Jensen, Annette S; Nordsborg, Nikolai

    2011-01-01

    with work rate would increase organ blood flow. Methods and Results- Invasively determined CO and leg blood flow and Doppler-determined cerebral perfusion were measured during 2 incremental cycle exercise tests on the same day in 8 patients provided with a HeartMate II LVAD. In random order, patients......Background- End-stage heart failure is associated with impaired cardiac output (CO) and organ blood flow. We determined whether CO and peripheral perfusion are maintained during exercise in patients with an axial-flow left ventricular assist device (LVAD) and whether an increase in LVAD pump speed...... exercised both with a constant (˜9775 rpm) and with an increasing pump speed (+400 rpm per exercise stage). At 60 W, the elevation in CO was more pronounced with increased pump speed (8.7±0.6 versus 8.1±1.1 L · min(-1); mean±SD; P=0.05), but at maximal exercise increases in CO (from 7.0±0.9 to 13.6±2.5 L...

  12. 46 CFR 132.120 - Fire pumps.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire pumps. 132.120 Section 132.120 Shipping COAST GUARD....120 Fire pumps. (a) Except as provided by § 132.100(b) of this subpart, each vessel must be equipped with one self-priming power-driven fire pump capable of delivering a single stream of water from...

  13. Sequential decays of the. Upsilon. prime prime

    Energy Technology Data Exchange (ETDEWEB)

    Heintz, U.; Kaarsberg, T.; Lee-Franzini, J.; Lovelock, D.M.J.; Narain, M.; Schamberger, R.D.; Willins, J.; Yanagisawa, C. (Department of Physics, State University of New York at Stony Brook, Stony Brook, New York 11794 (USA)); Franzini, P.; Tuts, P.M.; Kanekal, S.; Wu, Q. (Columbia University, New York, New York 10027 (USA))

    1991-03-25

    We have studied the decay chain {Upsilon}{prime}{prime}{r arrow}{chi}{sub {ital b}}{sup {prime}}({chi}{sub {ital b}}){gamma} {r arrow}{Upsilon}{prime}({Upsilon}){gamma}{gamma}{r arrow}{mu}{mu}({ital ee}){gamma}{gamma} with the CUSB II detector at the Cornell Electron Storage Ring. For a sample of 1.33{times}10{sup 6} {Upsilon}{prime}{prime}'s we find {approx}400 events. We measure branching ratios for {chi}{sub {ital b}{ital J}}{sup {prime}}{r arrow}{Upsilon}{prime}({Upsilon}){gamma} and, using calculated {ital E}1 rates, we derive total and hadronic widths of the {chi}{sub {ital b}}{sup {prime}} states. From these widths we obtain values of {alpha}{sub {ital s}} in the range between 0.13 and 0.21, in agreement with other determinations. We observe the suppressed decay {Upsilon}{prime}{prime}{r arrow}{chi}{sub {ital b}}{gamma}. The measured branching ratio suggests that relativistic effects are important. We also determine the branching ratios for {Upsilon}{prime}{prime}{r arrow}{Upsilon}{prime}{pi}{sup 0}{pi}{sup 0} to be (1.3{plus minus}0.4{plus minus}0.2)% and {Upsilon}{prime}{prime}{r arrow}{Upsilon}{pi}{sup 0}{pi}{sup 0} to be (1.8{plus minus}0.3{plus minus}0.2)%.

  14. Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: a computational modeling study.

    Science.gov (United States)

    Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton

    2015-02-01

    The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and

  15. Optimization and experiment on performance of flow-ejecting self-priming pump based on CFD%基于CFD的射流自吸泵性能优化与试验

    Institute of Scientific and Technical Information of China (English)

    王洋; 韩亚文; 朱新新; 孙伟; 曹璞钰; 吴文

    2016-01-01

    为提高射流自吸泵效率,该文选择关键结构参数射流器喉管直径、射流器出口直径、叶轮出口宽度和叶片数作为目标因素,设计四因素三水平正交试验,共9组试验。运用数值分析软件提供的湍流模型对各方案进行数值计算。通过极差分析确定性能最优参数组合,其中对效率影响最主要因素为喉管直径。以喉管直径为优化目标设计单一变量试验,分别在小流量点、额定流量点及大流量点进行数值计算,通过数据拟合得到正交试验最优参数组合在不同流量下以喉管直径为自变量的扬程、效率方程式,运用极值运算及加权平均得到最优喉管直径。试验结果表明:相比原型泵,优化模型在额定流量点效率提高约5%。该研究为同类泵的优化提供了一种较可靠的试验设计及数据处理方法。%In order to optimize the JSW10 type flow-ejecting self-priming pump, 4 key structural parameters are selected as target factors, which are outlet width of the impeller (FactorA), number of blades (FactorB), throat diameter of ejector (Factor C), and outlet diameter of ejector (FactorD), and the orthogonal experiment is designed with 4 factors and 3 levels, a total of 9 tests. The choice of structural parameters is mainly dependent on related research and the feasibility of parameter controlling in the tests is considered. Due to the complex geometry of the flow channel, the unstructured mesh which has good adaptability is adopted. Based on the grid independence, the numerical results tend to be stable when the grid number is above 3 million, and in this paper the mesh number of tests is between 3.6 million and 4 million. The whole flow field is simulated by the RNGk-ε model provided by ANSYS CFX, which turns out that the numerical results match well with the experiment data. Therefore, the numerical simulation can be used to predict the performance of the pump. We can get

  16. Innovative design to prevent reversal of roller blood pump rotation in the event of electromechanical failure: an easy solution to a devastating problem.

    Science.gov (United States)

    Skoletsky, Jennifer S; White, Brian T; Austin, Jon W

    2007-06-01

    Despite the advanced technologies of battery back-up for heart-lung consoles and the availability of system-wide generators, electromechanical failure is still occurring. Several heart-lung machine manufacturers still provide unsafe handcranking devices to use in the case of an emergency while using a roller blood pump. A new design has been engineered to eliminate safety and quality issues for the perfusionist and the patient when the need for handcranking presents itself. A ratchet-style handcranking device was fabricated by means of a steel plate with adjustable pins. The adjustable pins allow for use with different models of the Cobe, Stockert, and Jostra heart-lung consoles, which contain roller pumps with 1800 roller heads. Additional modifications such as a 1:2 transmission and fluorescent markers are also used in the design. This innovative design is an improvement in safety compared with the current handcrank provided by Cobe, Stockert, and Jostra. With this modified handcranking device, accidental reverse rotation of the roller pump head cannot occur. Fluorescent markers will improve visualization of the pump head in low-light situations. The ergonomic design improves efficiency by reducing fatigue. Most importantly, a "safe" safety device will replace the current design provided by these manufacturers, thus improving the quality of care by health care providers.

  17. Prime Mover

    DEFF Research Database (Denmark)

    Wagner, Michael Frederik

    2002-01-01

    The important issue of technological determinism is analysed in relation to various theoretical positions, and it is highlighted with a chain of empirical cases drawn form history. The fundamental questions to be considered is the nature of determinism in Karl Marx' philosophical work and the shi...... of modernism versus primitivism in historiography. This question is narrowed down to the discussion of the vertical water wheel as the prime mover in history. The problem is related to the abuse of technical development as an independent variable in general history....

  18. Prime Mover

    DEFF Research Database (Denmark)

    Wagner, Michael Frederik

    2002-01-01

    The important issue of technological determinism is analysed in relation to various theoretical positions, and it is highlighted with a chain of empirical cases drawn form history. The fundamental questions to be considered is the nature of determinism in Karl Marx' philosophical work and the shi...... of modernism versus primitivism in historiography. This question is narrowed down to the discussion of the vertical water wheel as the prime mover in history. The problem is related to the abuse of technical development as an independent variable in general history....

  19. THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM

    Directory of Open Access Journals (Sweden)

    E. G. Konysheva

    2010-01-01

    Full Text Available We analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as suction and regurgitation can be detected. These limits depend on the degree of cardiac failure, which confirms the need to control the speed of rotation of the impeller in the range of the cardiac failure from pathology to normal. It has been shown that the pulsating pressure at the inlet of the pump modulates the flow of the pump, making it a pulsating, what positively affects on the dynamics of cardiac output. 

  20. Five-week use of a monopivot centrifugal blood pump as a right ventricular assist device in severe dilated cardiomyopathy.

    Science.gov (United States)

    Inoue, Takamichi; Kitamura, Tadashi; Torii, Shinzo; Hanayama, Naoji; Oka, Norihiko; Itatani, Keiichi; Tomoyasu, Takahiro; Irisawa, Yusuke; Shibata, Miyuki; Hayashi, Hidenori; Ono, Minoru; Miyaji, Kagami

    2014-03-01

    Right heart failure is a critical complication in patients requiring mechanical ventricular support. However, it is often difficult to provide adequate right ventricular support in the acute phase. A 41-year-old woman diagnosed with dilated cardiomyopathy with severe right heart failure underwent implantation of a paracorporeal pulsatile left ventricular assist device (LVAD, Nipro Corporation, Tokyo, Japan) and a MERA monopivot centrifugal pump (Senko Medical Instrument Manufacturing Co., Ltd., Tokyo, Japan) as a right ventricular assist device (RVAD). The patient developed ischemic enteritis 3 weeks after surgery, necessitating fasting and reversal of anticoagulation therapy. A target international normalized ratio of 1.5 was selected, and aspirin administration was discontinued. Following recovery without thromboembolic events, the patient failed the RVAD discontinuation test. Five weeks after surgery, the monopivot centrifugal pump was exchanged for a pulsatile pump. No thrombus was evident on the centrifugal pump. The patient was undergoing cardiac rehabilitation at the time of this writing and awaiting heart transplantation.

  1. Avaliação de tanques de escorva utilizados em substituição à válvula-de-pé em instalações de bombeamento Evaluation of priming tanks using them instead of foot valve in pumping installations

    Directory of Open Access Journals (Sweden)

    Marcos O. Betini

    2008-09-01

    Full Text Available A maioria das instalações de abastecimento de água utiliza bombas hidráulicas do tipo turbobombas, requerendo que o interior de sua carcaça e da tubulação de sucção esteja preenchido com água (escorvados para que a sucção da água possa ser efetivada. O escorvamento das bombas pode ser efetuado instalando-as abaixo do reservatório de captação (bomba afogada. Quando a bomba está acima do reservatório e o escorvamento é manual, é necessário usar válvulas-de-pé, que são suscetíveis ao mau funcionamento, limitando a confiabilidade do sistema, principalmente em caso de automação. Como alternativa à válvula-de-pé, neste trabalho, foram estudados dois tanques escorva, testados no Laboratório de Hidráulica e Irrigação da FCAV/UNESP - Jaboticabal, avaliando-se situações de altura manométrica de sucção de bomba centrífuga e relações entre volume útil do tanque e volume do tubo de sucção, tendo-se concluído: a o volume do tanque de escorva é função do volume do tubo de sucção da instalação de bombeamento e da altura manométrica de sucção; b o volume do tanque de escorva pode ser calculado seguindo-se a Lei de Boyle, com percentagem de acréscimo que, neste estudo, foi de 10% para um modelo de tanque e de 30% para o segundo modelo.The majority of water supply installations use hydraulic pump-turbines, requiring their inner casing and suction pipe be water filled (primed, to allow water suction. Pumps priming can be carried out installing them under the suction reservoir (drowned pump. When pump is above the reservoir and priming is manual, it will be necessary using foot valves, which are subjected to bad working, with a reduction of system reliability, mainly with automation. In this work, as an alternative to foot valves, two priming tanks were inquired, tested in the FCAV/UNESP-Jaboticabal, Brazil, Laboratory of Hydraulics and Irrigation, with the evaluation of suction head situations of centrifugal

  2. Soluble CD40 ligand accumulates in stored blood components, primes neutrophils through CD40, and is a potential cofactor in the development of transfusion-related acute lung injury

    Science.gov (United States)

    Khan, Samina Yasmin; Kelher, Marguerite R.; Heal, Joanna M.; Blumberg, Neil; Boshkov, Lynn K.; Phipps, Richard; Gettings, Kelly F.; McLaughlin, Nathan J.; Silliman, Christopher C.

    2006-01-01

    Transfusion-related acute lung injury (TRALI) is a form of posttransfusion acute pulmonary insufficiency that has been linked to the infusion of biologic response modifiers (BRMs), including antileukocyte antibodies and lipids. Soluble CD40 ligand (sCD40L) is a platelet-derived proinflammatory mediator that accumulates during platelet storage. We hypothesized that human polymorpho-nuclear leukocytes (PMNs) express CD40, CD40 ligation rapidly primes PMNs, and sCD40L induces PMN-mediated cytotoxicity of human pulmonary microvascular endothelial cells (HMVECs). Levels of sCD40L were measured in blood components and in platelet concentrates (PCs) implicated in TRALI or control PCs that did not elicit a transfusion reaction. All blood components contained higher levels of sCD40L than fresh plasma, with apheresis PCs evidencing the highest concentration of sCD40L followed by PCs from whole blood, whole blood, and packed red blood cells (PRBCs). PCs implicated in TRALI reactions contained significantly higher sCD40L levels than control PCs. PMNs express functional CD40 on the plasma membrane, and recombinant sCD40L (10 ng/mL-1 μg/mL) rapidly (5 minutes) primed the PMN oxidase. Soluble CD40L promoted PMN-mediated cytotoxicity of HMVECs as the second event in a 2-event in vitro model of TRALI. We concluded that sCD40L, which accumulates during blood component storage, has the capacity to activate adherent PMNs, causing endothelial damage and possibly TRALI in predisposed patients. PMID:16772606

  3. On Chip Bioelectric Impedance Spectroscopy Reveals the Effect of P-Glycoprotein Efflux Pumps on the Paracellular Impedance of Tight Junctions at the Blood-Brain Barrier.

    Science.gov (United States)

    Kraya, Ramsey; Komin, Alexander; Searson, Peter

    2016-10-01

    Bioelectric impedance spectroscopy was used to elucidate the influence of P-gp efflux pumps on the kinetics of tight junction down-regulation in confluent monolayers of Madine Darby Canine Kidney Epithelial Cells (MDCK) following administration of phenylarsine oxide (PAO), a molecule that inhibits protein tyrosine phosphatases (PTP) and induces matrix metalloproteinase activity. Matrix metalloproteinases (MMPs) and phosphatase inhibitors induce modification of occludin tight junction proteins critical for the proper function of the blood-brain barrier. The addition of PAO to MDCKII cell lines resulted in a dramatic decrease in monolayer resistance. In contrast, MDCKII-MDR1 cells transfected with the MDR1 gene treated with PAO showed an initial decrease in monolayer resistance followed by a partial recovery and subsequent decrease. This resistance decay reversal was suppressed with the addition of the P-glycoprotein (P-gp) pump inhibitor elacridar, and is attributed to PAO efflux. These results illustrate impedance spectroscopy can be used to characterize the competing kinetics of efflux and down-regulation of tight junctions. In addition, the resistance decay reversal effect can be used to evaluate P-gp pump inhibitor efficacy.

  4. ON ALMOST PRIME SUBMODULES

    Institute of Scientific and Technical Information of China (English)

    Hani A. Khashan

    2012-01-01

    In this article,we define almost prime submodules as a new generalization of prime and weakly prime submodules of unitary modules over a commutative ring with identity.We study some basic properties of almost prime submodules and give some characterizations of them,especially for (finitely generated faithful) multiplication modules.

  5. 一种植入式磁悬浮离心血泵的体外流体力学实验研究%Experimental Study of Hydrodynamic in Vitro of an Implantable Magnetic Levitation Blood Pump

    Institute of Scientific and Technical Information of China (English)

    郭龙辉; 张杰民; 赵龙; 刘晓程

    2011-01-01

    To study hydrodynamic in vitro of an implantahle magnetic levitation blood pump using vitro test loop. The fresh sheep blood was prepared for the circulating medium. The output of the pump was tested at the different speeds against 100 mmHg; by controlling the pump's speed, the output of the pump was tested against different afterload.The blood pump worked at 24 V and the electric current was 0.3-0.75 A. Power consumption of the pump was 7.2-18 W. At 2 900-3 900 rpm, the pump generated 3~7.1L/min flow against 10.0 mmHg. At 2500~3500 rpm, the pump generated 1.02~5.87 L/min flow against 69~63 mmHg. The relationship between pressure and flow was negative correlation at fixed pump's speed. The blood pump works stably in vitro test. The pump can meet the need of adult's ventricular assist, but power consumption of the pump needs further improvement.%通过体外模拟循环实验台对一种植入式磁悬浮离心血泵进行体外流体力学实验.以新鲜羊血为循环介质,通过体外循环台测定在后负荷为100 mmHg,血泵在不同转速下的输出量;通过控制血泵的转速,测定在固定泵速下不同后负荷下的输出量.血泵测试工作电压为24V,电流波动于0.3~0.75 A.血泵功率为7.2~18W.在后负荷为100 mmHg下,泵速在2 900~3 900 rpm,输出流量为3~7.1 L/min.泵速为2 500~3 500rpm,血泵在后负荷69~ 163 mmHg下输出流量为1.02 ~ 5.87 L/min.在固定的转速下血泵的压力-流量呈负相关关系.体外实验血泵工作性能稳定,可以满足成人心室辅助的需求.血泵功率偏高仍需要进一步改进.

  6. Motor Priming in Neurorehabilitation

    OpenAIRE

    Stoykov, Mary Ellen; Madhavan, Sangeetha

    2015-01-01

    Priming is a type of implicit learning wherein a stimulus prompts a change in behavior. Priming has been long studied in the field of psychology. More recently, rehabilitation researchers have studied motor priming as a possible way to facilitate motor learning. For example, priming of the motor cortex is associated with changes in neuroplasticity that are associated with improvements in motor performance. Of the numerous motor priming paradigms under investigation, only a few ...

  7. Motor Priming in Neurorehabilitation

    OpenAIRE

    Stoykov, Mary Ellen; Madhavan, Sangeetha

    2015-01-01

    Priming is a type of implicit learning wherein a stimulus prompts a change in behavior. Priming has been long studied in the field of psychology. More recently, rehabilitation researchers have studied motor priming as a possible way to facilitate motor learning. For example, priming of the motor cortex is associated with changes in neuroplasticity that are associated with improvements in motor performance. Of the numerous motor priming paradigms under investigation, only a few ...

  8. Efficient Prime Counting and the Chebyshev Primes

    Directory of Open Access Journals (Sweden)

    Michel Planat

    2013-01-01

    Full Text Available The function where is the logarithm integral and the number of primes up to is well known to be positive up to the (very large Skewes' number. Likewise, according to Robin's work, the functions and , where and are Chebyshev summatory functions, are positive if and only if Riemann hypothesis (RH holds. One introduces the jump function at primes and one investigates , , and . In particular, , and for . Besides, for any odd , an infinite set of the so-called Chebyshev primes. In the context of RH, we introduce the so-called Riemann primes as champions of the function (or of the function . Finally, we find a good prime counting function , that is found to be much better than the standard Riemann prime counting function.

  9. Pump/Control System Minimum Operating Cost Testing

    Science.gov (United States)

    1977-01-01

    A preliminary evaluation of pump performance was initiated to determine the efficiencies of an arbitrary group of small pumps. Trends in factors affecting energy usage in typical prime movers which might be used in liquid transport solar systems were assessed. Comparisons of centrifugal pump efficiencies were made from one manufacturer to another. Tests were also made on two positive-displacement pumps and comparisons with centrifugal pumps were observed.

  10. Oxygenation to Bovine Blood in Artificial Heart and Lung Using Vibrating Flow Pump: Experiment and Numerical Analysis Based on Non-Newtonian Model

    Science.gov (United States)

    Shintaku, Hirofumi; Yonemura, Tsubasa; Tsuru, Kazuaki; Isoyama, Takashi; Yambe, Tomoyuki; Kawano, Satoyuki

    In this study, we construct an experimental apparatus for a prototype artificial heart and lung (AHL) by installing hollow fibers into the cylindrical tube of the vibrating flow pump (VFP). The oxygenation characteristics are investigated both by experiments using bovine blood and by numerical analyses based on the computational fluid dynamics. The analyses are carried out at the Reynolds numbers Re ranged from O(1) to O(103), which are determined based on the experimental conditions. The blood flow and the diffusion of oxygen gas are analyzed based on the Newtonian/non-Newtonian, unsteady, incompressible and axisymmetric Navier-Stokes equations, and the advection-diffusion equation. The results show that the oxygenation rate increases in proportion to Re1/3, where the phenomenon corresponds to the decreasing thickness of the concentration boundary layer with Re. Although the effects of the vibrating flow and the rheology of the blood are clearly appeared on the velocity field, their effects on the gas exchange are relatively small at the ranges of prescribed Reynolds numbers. Furthermore, the numerical results in terms of the oxygenation rate are compared with the experimental ones. The basic design data of VFP were accumulated for the development of AHL in the clinical applications.

  11. Almost Graded Prime Ideals

    Directory of Open Access Journals (Sweden)

    Ameer Jaber

    2008-01-01

    Full Text Available Problem Statement: Graded commutative ring with unity over an abelian group were introduced by many authors such as T. Y. Lam and C. T. C. Wall, and almost prime ideals over commutative rings with unity were introduced by S.M. Batwadeker and P.K. Sharma, and this forced us to try to extend the theory of almost and n-almost prime ideals to the graded case. Approach: We develop the theory of almost and n-almost prime ideals to the graded case. Results: We extended some basic results about almost and n-almost prime ideals to the graded case, and then we gave a relationship between n-almost graded prime ideals and weakly graded prime ideals. Conclusion: The extended results about almost and n-almost graded prime ideals allow us to classify further properties about almost graded prime ideals. 2000 AMS Mathematics Subject Classification: 13 A 02.

  12. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  13. Pumps in wearable ultrafiltration devices: pumps in wuf devices.

    Science.gov (United States)

    Armignacco, Paolo; Garzotto, Francesco; Bellini, Corrado; Neri, Mauro; Lorenzin, Anna; Sartori, Marco; Ronco, Claudio

    2015-01-01

    The wearable artificial kidney (WAK) is a device that is supposed to operate like a real kidney, which permits prolonged, frequent, and continuous dialysis treatments for patients with end-stage renal disease (ESRD). Its functioning is mainly related to its pumping system, as well as to its dialysate-generating and alarm/shutoff ones. A pump is defined as a device that moves fluids by mechanical action. In such a context, blood pumps pull blood from the access side of the dialysis catheter and return the blood at the same rate of flow. The main aim of this paper is to review the current literature on blood pumps, describing the way they have been functioning thus far and how they are being engineered, giving details about the most important parameters that define their quality, thus allowing the production of a radar comparative graph, and listing ideal pumps' features.

  14. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    of membrane proteins: P-type ATPase pumps. This article takes the reader on a tour from Aarhus to Copenhagen, from bacteria to plants and humans, and from ions over protein structures to diseases caused by malfunctioning pump proteins. The magazine Nature once titled work published from PUMPKIN ‘Pumping ions......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  15. Blood

    Science.gov (United States)

    ... Also, blood is either Rh-positive or Rh-negative. So if you have type A blood, it's either A positive or A negative. Which type you are is important if you need a blood transfusion. And your Rh factor could be important ...

  16. Optimal design of the hydrodynamic multi-arc bearing in a centrifugal blood pump for the improvement of bearing stiffness and hemolysis level.

    Science.gov (United States)

    Yasui, Kazuya; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Kawaguchi, Yasuo; Yamane, Takashi

    2013-09-01

    The purpose of the present study is to establish an optimal design of the multi-arc hydrodynamic bearing in a centrifugal blood pump for the improvement of bearing stiffness and hemolysis level. The multi-arc bearing was designed to fulfill the required specifications: (i) ensuring the uniform bearing stiffness for various bearing angles; (ii) ensuring a higher bearing stiffness than the centrifugal force to prevent impeller whirl; and (iii) adjusting the bearing clearance as much as possible to reduce hemolysis. First, a numerical analysis was performed to optimize three design parameters of the multi-arc bearing: number of arcs N, bearing clearance C, and groove depth H. To validate the accuracy of the numerical analysis, the impeller trajectories for six pump models were measured. Finally, an in vitro hemolysis test was conducted to evaluate the hemolytic property of the multi-arc bearing. As a result of the numerical analysis, the optimal parameter combination was determined as follows: N=4, C=100 μm, and H ≥ 100 μm. In the measurements of the impeller trajectory, the optimal parameter combination was found to be as follows: N=4, C=90 μm, and H=100 μm. This result demonstrated the high reliability of the numerical analysis. In the hemolysis test, the parameter combination that achieved the smallest hemolysis was obtained as follows: N=4, C=90 μm, and H=100 μm. In conclusion, the multi-arc bearing could be optimized for the improvement of bearing stiffness and hemolysis level.

  17. Effect of ultraviolet blood irradiation and oxygenation on nerve function and function of the red blood cell membrane pump in patients with acute cerebral infarction

    Institute of Scientific and Technical Information of China (English)

    Jiaquan Wang; Chun Mao; Kaifu Ma; Shiqing Wang

    2006-01-01

    BACKGROUND: Ultraviolet blood irradiation and oxygenation (UBIO) has obtained better clinical effect in treating acute cerebral infarction, but the mechanism underlying this effect remains unclear.OBJECTIVE: To observe the effect of UBIO on the nerve function and activities of K+-Na+-ATPase and Ca2+-Mg2+-ATPase activities on the red blood cell (RBC) membrane of patients with acute cerebral infarction.DESIGN: A randomized and controlled study.SETTING: Department of Neurology, Xiangfan Central Hospital.PARTICIPANTS: From January 2000 to December 2001, excluding those above 70 years old, 58 cases of 700 patients with acute cerebral infarction admitted in the Department of Neurology, Xiangfan Central Hospital, were recruited and divided into two groups according to the random number table: UBIO treated group (n=28), including 17 males and 11 females, aged 40-68 years; and control group (n=30), including 20males and 10 females, aged 44-69 years. All the patients agreed to participate in the therapeutic program and detected items. The general informations were comparable without obvious differences between the two groups (P > 0.05).METHODS: ① The patients in both groups received routine treatments, besides, those in the UBIO treated group were given UBIO treatment by using the XL-200 type therapeutic apparatus produced in Shijiazhuang, whose ultraviolet wave was set at 253.7 nm with the energy density of 0.568 J/m2 per second, UBIO treatment started from the second day after admission, once every other day, with a single course consisting of 5-7 treatments. ② In the UBIO treated group, the venous blood was sampled before and after the first, third and the completion of the treatment course respectively, the venous blood was taken at each corresponding time point in the control group. After centrifugation of the blood at 10 000 rounds per minute,the RBC membrane was separated and then the activities of K+-Na+-ATPase and Ca2+-Mg2+-ATPase were detected by means of

  18. Magnetocaloric pump

    Science.gov (United States)

    Brown, G. V.

    1973-01-01

    Very cold liquids and gases such as helium, neon, and nitrogen can be pumped by using magnetocaloric effect. Adiabatic magnetization and demagnetization are used to alternately heat and cool slug of pumped fluid contained in closed chamber.

  19. Technology assessment heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Rudolph, R.; Purper, G. (Battelle-Institut e.V., Frankfurt am Main (Germany, F.R.))

    Technology assessment for an increased application of heat pumps is carried out in four areas: Effects in the economics area, i.e. effects on the economic goals which are defined in the Stability Law, on the goals of the power supply policy which result from the energy programme and its projections, and on the economic structure as a whole. The whole range of social problems concerning the use of heat pumps, i.e. the questions which social groups are affected, how they react, and what consequences are they expected to have on energy conservation as an object of social policy. Consequences in the governmental and administrative sectors, i.e. effects on legislation, administration and government budgets. Effects on the ecological systems; of prime interest in this context are the utilisation of environmental energy, changes in the heat balance, and emmission of pollutants.

  20. An ERP investigation of orthographic priming with superset primes.

    Science.gov (United States)

    Ktori, Maria; Midgley, Katherine; Holcomb, Phillip J; Grainger, Jonathan

    2015-01-12

    Prime stimuli formed by inserting unrelated letters in a given target word (called "superset" primes) provide a means to modify the relative positions of the letters shared by prime and target. Here we examined the time-course of superset priming effects in an ERP study using the sandwich-priming paradigm. We compared the effects of superset primes formed by the insertion of unrelated letters (e.g., maurkdet-MARKET), or by the insertion of hyphens (e.g., ma-rk-et-MARKET), with identity priming (e.g., market-MARKET), all measured relative to unrelated control primes. Behavioral data revealed significantly greater priming in the hyphen-insert condition compared with the letter-insert condition. In the ERP signal, letter-insert priming emerged later than hyphen-insert priming and produced a reversed priming effect in the N400 time-window compared with the more typical N400 priming effects seen for both hyphen-insert priming and identity priming. The different pattern of priming effects seen for letter-insert primes and hyphen-insert primes suggests that compared with identity priming, letter superset priming reflects the joint influence of: (1) a disruption in letter position information, and (2) an inhibitory influence of mismatching letters.

  1. Dynamics of structural priming

    OpenAIRE

    Malhotra, Gaurav

    2009-01-01

    This thesis is about how our syntactic choice changes with linguistic experience. Studies on syntactic priming show that our decisions are influenced by sentences that we have recently heard or recently spoken. They also show that not all sentences have an equal amount of influence; that repetition of verbs increases priming (the lexical-boost effect) and that some verbs are more susceptible to priming than others. This thesis explores how and why syntactic decisions change with time and what...

  2. Priming semantico e museografia

    OpenAIRE

    Annalisa Banzi

    2012-01-01

    Il priming è una tipologia di memoria implicita che facilita l’apprendimento di stimoli di diversa natura (stimoli visivi, semantici, etc.). Un allestimento museale che adotti strumenti basati sul priming potrebbe aiutare il pubblico a selezionare i contenuti relativi agli oggetti esposti. In questo articolo viene descritta l’applicazione del priming semantico allo spazio museale. Questa operazione in prima battutta potrebbe essere letta come una mancanza di fiducia nelle capacità cognitive d...

  3. Jarvik 2000 pump technology and miniaturization.

    Science.gov (United States)

    Jarvik, Robert

    2014-01-01

    Blood-pump miniaturization has made amazing progress, reducing the pump diameter to one-tenth of the size of previous positive displacement pumps. In particular, axial-flow-pump technology allows tiny pumps running at high speeds to deliver from 2 to 10 L/min. A review of the background inventions of the Jarvik 2000 technology is presented, together with the reason that making pumps smaller than demanded by the particular application for which they are designed is counterproductive. Pump miniaturization is nearing its practical limit. The optimization of performance and patient outcomes should remain our primary design goal.

  4. Prime tight frames

    DEFF Research Database (Denmark)

    Lemvig, Jakob; Miller, Christopher; Okoudjou, Kasso A.

    2014-01-01

    to suggest effective analysis and synthesis computation strategies for such frames. Finally, we describe all prime frames constructed from the spectral tetris method, and, as a byproduct, we obtain a characterization of when the spectral tetris construction works for redundancies below two.......We introduce a class of finite tight frames called prime tight frames and prove some of their elementary properties. In particular, we show that any finite tight frame can be written as a union of prime tight frames. We then characterize all prime harmonic tight frames and use thischaracterization...

  5. F1000 prime reports

    National Research Council Canada - National Science Library

    F1000 Prime is a revolutionary post-publication peer review service that comprehensively and systematically highlights and recommends the most interesting articles published in the biomedical sciences...

  6. Heat pumps

    CERN Document Server

    Macmichael, DBA

    1988-01-01

    A fully revised and extended account of the design, manufacture and use of heat pumps in both industrial and domestic applications. Topics covered include a detailed description of the various heat pump cycles, the components of a heat pump system - drive, compressor, heat exchangers etc., and the more practical considerations to be taken into account in their selection.

  7. A web-based study of the relationship of duration of insulin pump infusion set use and fasting blood glucose level in adults with type 1 diabetes.

    Science.gov (United States)

    Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W

    2015-05-01

    To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.

  8. Development of a jet pump-assisted arterial heat pipe

    Science.gov (United States)

    Bienert, W. B.; Ducao, A. S.; Trimmer, D. S.

    1977-01-01

    The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.

  9. Effect of the colloids gelatin and HES 130/0.4 on blood coagulation in cardiac surgery patients: a randomized controlled trial.

    Science.gov (United States)

    Kimenai, D M; Bastianen, G W; Daane, C R; Megens-Bastiaanse, C M; van der Meer, N J M; Scohy, T V; Gerritse, B M

    2013-11-01

    The choice of the prime solution for cardiopulmonary bypass can play an important role in limiting the effect on blood coagulation, but it is still unclear what the effect of colloids on blood coagulation is. The aim of this study was to investigate the effect of synthetic colloids on blood loss and blood coagulation in patients after on-pump coronary artery bypass graft (CABG) procedures. Sixty elective, on-pump CABG patients were randomly assigned to receive the prime solutions lactated Ringer's solution combined with hydroxyethyl starch 130/0.4 (HES, 6% Volulyte, Fresenius Kabi Nederland BV, Zeist, the Netherlands) (HES group) or gelatin (Gelofusin(®), B Braun Melsung AG, Melsungen, Germany) (Gelo group). Blood loss was assessed using post-operative chest tube output; secondary endpoints were number of blood component transfusions, routine coagulation test values and rotation thromboelastometry values (Rotem(®) delta, Pentapharm GmbH, Munich, Germany). Total post-operative chest tube output was 500 ± 420 ml in the HES group versus 465 ± 390 ml in the Gelo group (p = 0.48). No significant differences were observed in any of the routine coagulation tests values, thromboelastometry parameters or number of blood component transfusions between the groups. In this randomized, controlled trial of adults after on-pump CABG procedures, there was no significant difference in blood loss or blood coagulation between the HES group and the Gelo group.

  10. Heat pumps

    CERN Document Server

    Brodowicz, Kazimierz; Wyszynski, M L; Wyszynski

    2013-01-01

    Heat pumps and related technology are in widespread use in industrial processes and installations. This book presents a unified, comprehensive and systematic treatment of the design and operation of both compression and sorption heat pumps. Heat pump thermodynamics, the choice of working fluid and the characteristics of low temperature heat sources and their application to heat pumps are covered in detail.Economic aspects are discussed and the extensive use of the exergy concept in evaluating performance of heat pumps is a unique feature of the book. The thermodynamic and chemical properties o

  11. Extreme high-head portables provide more pumping options

    Energy Technology Data Exchange (ETDEWEB)

    Fiscor, S.

    2006-10-15

    Three years ago, Godwin Pumps, one of the largest manufacturers of portable pumps, introduced its Extreme Duty High Lift (HL) series of pumps and more mines are finding unique applications for these pumps. The Extreme HL series is a range single-stage Dri-Prime pumps with heads up to 600 feet and flows up to 5,000 gallons per minute. The American Coal Co.'s Galatia mine, an underground longwall mine in southern Illinois, used an HL 160 to replace a multiple-staged centrifugal pump. It provided Galatia with 1,500 gpm at 465 ft. 3 photos.

  12. Priming Ability Emotional Intelligence

    Science.gov (United States)

    Schutte, Nicola S.; Malouff, John M.

    2012-01-01

    Two studies examined whether priming self-schemas relating to successful emotional competency results in better emotional intelligence performance. In the first study participants were randomly assigned to a successful emotional competency self-schema prime condition or a control condition and then completed an ability measure of emotional…

  13. Priming Ability Emotional Intelligence

    Science.gov (United States)

    Schutte, Nicola S.; Malouff, John M.

    2012-01-01

    Two studies examined whether priming self-schemas relating to successful emotional competency results in better emotional intelligence performance. In the first study participants were randomly assigned to a successful emotional competency self-schema prime condition or a control condition and then completed an ability measure of emotional…

  14. Discovery: Prime Numbers

    Science.gov (United States)

    de Mestre, Neville

    2008-01-01

    Prime numbers are important as the building blocks for the set of all natural numbers, because prime factorisation is an important and useful property of all natural numbers. Students can discover them by using the method known as the Sieve of Eratosthenes, named after the Greek geographer and astronomer who lived from c. 276-194 BC. Eratosthenes…

  15. Building Numbers from Primes

    Science.gov (United States)

    Burkhart, Jerry

    2009-01-01

    Prime numbers are often described as the "building blocks" of natural numbers. This article shows how the author and his students took this idea literally by using prime factorizations to build numbers with blocks. In this activity, students explore many concepts of number theory, including the relationship between greatest common factors and…

  16. Recognizing plant defense priming

    NARCIS (Netherlands)

    Martinez-Medina, A.; Flors, V.; Heil, M.; Mauch-Mani, B.; Pieterse, C.M.J.; Pozo, M.J.; Ton, J.; Van Dam, N.M.; Conrath, U.

    2016-01-01

    Defense priming conditions diverse plant species for the superinduction of defense, often resulting in enhanced pest and disease resistance and abiotic stress tolerance. Here, we propose a guideline that might assist the plant research community in a consistent assessment of defense priming in plant

  17. The semantic priming project.

    Science.gov (United States)

    Hutchison, Keith A; Balota, David A; Neely, James H; Cortese, Michael J; Cohen-Shikora, Emily R; Tse, Chi-Shing; Yap, Melvin J; Bengson, Jesse J; Niemeyer, Dale; Buchanan, Erin

    2013-12-01

    Speeded naming and lexical decision data for 1,661 target words following related and unrelated primes were collected from 768 subjects across four different universities. These behavioral measures have been integrated with demographic information for each subject and descriptive characteristics for every item. Subjects also completed portions of the Woodcock-Johnson reading battery, three attentional control tasks, and a circadian rhythm measure. These data are available at a user-friendly Internet-based repository ( http://spp.montana.edu ). This Web site includes a search engine designed to generate lists of prime-target pairs with specific characteristics (e.g., length, frequency, associative strength, latent semantic similarity, priming effect in standardized and raw reaction times). We illustrate the types of questions that can be addressed via the Semantic Priming Project. These data represent the largest behavioral database on semantic priming and are available to researchers to aid in selecting stimuli, testing theories, and reducing potential confounds in their studies.

  18. Prime Submodules and Flat Modules

    Institute of Scientific and Technical Information of China (English)

    A.AZIZI

    2007-01-01

    In this paper, some characterizations of prime submodules in fiat modules and, particularly,in free modules are given. Furthermore, the height of prime submodules and some saturated chain of prime submodules are also given.

  19. System design of magnetic bearings in an axial-flow artificial blood pump%轴流式磁悬浮人工心脏泵磁悬浮轴承系统设计

    Institute of Scientific and Technical Information of China (English)

    关勇; 李红伟; 刘淑琴

    2011-01-01

    The artificial blood pump has to meet the following advantages, small volume and mass and low power consumption. Radial permanent magnetic bearings (RPMBs) and axial electromagnetic bearings (AEMBs) were employed in the magnetic levitated artificial blood pump to suspend the rotor in five degree of freedoms (DOFs) and to meet the above requirements. According to the mechanical equilibrium condition of the blood pump rotor, two structure design methods were presented for the magnetic levitated system of the blood pump. One can be called the low power consumption design method and the other can be called the single axial EMB design method. The design principals of radial PMB and axial EMB in the two methods were given. Compared with the first method, the second method simplifies the blood pump structure and the axial EMB' s controller, and greatly reduces the pump volume and mass, though it maybe require more power consumption. A prototype axial-flow magnetic levitated blood pump was designed and manufactured according to the second method. Experimental results showed that the rotor was successfully and stably suspended in five DOFs by radial PMBs and only one axial EMB. These results showed that the magnetic bearing system structure design method presented is feasible. This study will provide references to the structure design of the magnetic levitated artificial blood pump.%人工心脏泵要求体积小、质量轻、功耗低.为契合上述要求,实现人工心脏泵转子的五自由度全悬浮,采用径向永磁轴承和轴向电磁轴承相结合的磁悬浮系统,在对轴流式人工心脏泵转子受力分析的基础上,提出了低功耗和单轴向电磁轴承这两种磁悬浮轴承系统结构设计方法,给出了采用这两种方法进行结构设计时,径向永磁轴承和轴向电磁轴承的设计原则.比较来看,采用单轴向电磁轴承结构设计方法虽然会增加电磁轴承的功耗,但是大大降低了系统的体积和质

  20. Centrifugal pumps

    CERN Document Server

    Gülich, Johann Friedrich

    2014-01-01

    This book gives an unparalleled, up-to-date, in-depth treatment of all kinds of flow phenomena encountered in centrifugal pumps including the complex interactions of fluid flow with vibrations and wear of materials. The scope includes all aspects of hydraulic design, 3D-flow phenomena and partload operation, cavitation, numerical flow calculations, hydraulic forces, pressure pulsations, noise, pump vibrations (notably bearing housing vibration diagnostics and remedies), pipe vibrations, pump characteristics and pump operation, design of intake structures, the effects of highly viscous flows, pumping of gas-liquid mixtures, hydraulic transport of solids, fatigue damage to impellers or diffusers, material selection under the aspects of fatigue, corrosion, erosion-corrosion or hydro-abrasive wear, pump selection, and hydraulic quality criteria. As a novelty, the 3rd ed. brings a fully analytical design method for radial impellers, which eliminates the arbitrary choices inherent to former design procedures. The d...

  1. Insulin pump therapy in pregnancy.

    Science.gov (United States)

    Kesavadev, Jothydev

    2016-09-01

    Control of blood glucose during pregnancy is difficult because of wide variations, ongoing hormonal changes and mood swings. The need for multiple injections, pain at the injection site, regular monitoring and skillful handling of the syringes/pen further makes insulin therapy inconvenient. Insulin pump is gaining popularity in pregnancy because it mimics the insulin delivery of a healthy human pancreas. Multiple guidelines have also recommended the use of insulin pump in pregnancy to maintain the glycaemic control. The pump can release small doses of insulin continuously (basal), or a bolus dose close to mealtime to control the spike in blood glucose after a meal and the newer devices can shut down insulin delivery before the occurrence of hypoglycaemia. Pump insulin of choice is rapid acting analogue insulin. This review underscores the role of insulin pump in pregnancy, their usage, advantages and disadvantages in the light of existing literature and clinic experience.

  2. Centrifugal pump inlet pressure site affects measurement.

    Science.gov (United States)

    Augustin, Simon; Horton, Alison; Butt, Warwick; Bennett, Martin; Horton, Stephen

    2010-09-01

    During extracorporeal life support (ECLS), blood is exposed to a myriad of unphysiological factors that can affect outcome. One aspect of this is the sub-atmospheric pressure generated by the ECLS pump and imparted to blood elements along the pump inlet line. This pressure can be measured on the inlet line close to the pump head by adding a connector, or at the venous cannula connection site. We compared the two measurement sites located at both points; between the venous cannula-inlet tubing and inlet tubing-pump, with a range of cannulae and flows. We also investigated the effects on inlet pressure from pump afterload and increasing inlet tubing length.

  3. A Relation between Prime Numbers and Twin Prime Numbers

    OpenAIRE

    2001-01-01

    Every mathematician has been concerned with prime numbers, and has metwith mysterious surprises about them. Besides intuition, using empirical methods has an important role to findrelations between prime numbers. A relation between any prime numberand any twin prime number has been obtained.

  4. Ferroelectric Pump

    Science.gov (United States)

    Jalink, Antony, Jr. (Inventor); Hellbaum, Richard F. (Inventor); Rohrbach, Wayne W. (Inventor)

    2000-01-01

    A ferroelectric pump has one or more variable volume pumping chambers internal to a housing. Each chamber has at least one wall comprising a dome shaped internally prestressed ferroelectric actuator having a curvature and a dome height that varies with an electric voltage applied between an inside and outside surface of the actuator. A pumped medium flows into and out of each pumping chamber in response to displacement of the ferroelectric actuator. The ferroelectric actuator is mounted within each wall and isolates each ferroelectric actuator from the pumped medium, supplies a path for voltage to be applied to each ferroelectric actuator, and provides for positive containment of each ferroelectric actuator while allowing displacement of the entirety of each ferroelectric actuator in response to the applied voltage.

  5. Water Pump Development for the EVA PLSS

    Science.gov (United States)

    Schuller, Michael; Kurwitz, Cable; Goldman, Jeff; Morris, Kim; Trevino, Luis

    2009-01-01

    This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently

  6. MedTech Mag-Lev, single-use, extracorporeal magnetically levitated centrifugal blood pump for mid-term circulatory support.

    Science.gov (United States)

    Nagaoka, Eiki; Fujiwara, Tatsuki; Kitao, Takashi; Sakota, Daisuke; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2013-01-01

    Short- to mid-term extracorporeal ventricular assist devices (VADs) are recommended for critical cardiogenic shock patients. We have designed a preclinical, single-use MedTech Mag-Lev VAD for one-month extracorporeal use. The impeller-rotor of the pump was suspended by a two degree-of-freedom active magnetic bearing in a 300 μm fluid gap, where the computational fluid dynamics analysis predicted a secondary flow of about 400-500 ml/min at a pump speed of 1800-2200 rpm. Three eddy current sensors were employed to implement noise- and drift-free magnetic levitation. The pump components were injection molded using polycarbonate for smooth surfaces as well as improved reproducibility, followed by coating with a biocompatible 2-methacryloyl-oxyethyl phosphorylcholine polymer. Chronic animal experiments were performed in nine calves. Three of the nine calves were excluded from analysis for problems with the circuit. Five of the six (83.3%) completed the 60 day duration of the study, while one prematurely died of massive bleeding due to inflow port detachment. The pump did not stop due to magnetic-levitation malfunction. Neither pump thrombosis nor major organ infarction was observed at autopsy. In comparison to machined surfaces, the injection-molded pump surfaces were thrombus-free after 60 day implantation. This study demonstrates the feasibility of MedTech Mag-Lev VAD for 60 day circulatory support.

  7. Heterologous Prime-Boost Vaccination

    OpenAIRE

    Lu, Shan

    2009-01-01

    An effective vaccine usually requires more than one time immunization in the form of prime-boost. Traditionally the same vaccines are given multiple times as homologous boosts. New findings suggested that prime-boost can be done with different types of vaccines containing the same antigens. In many cases such heterologous prime-boost can be more immunogenic than homologous prime-boost. Heterologous prime-boost represents a new way of immunization and will stimulate better understanding on the...

  8. The Set of Prime Numbers

    CERN Document Server

    Iovane, Gerardo

    2007-01-01

    In this work we show that the prime distribution is deterministic. Indeed the set of prime numbers P can be expressed in terms of two subsets of N using three specific selection rules, acting on two sets of prime candidates. The prime candidates are obtained in terms of the first perfect number. The asymptotic behaviour is also considered. We obtain for the first time an explicit relation for generating the full set P of prime numbers smaller than n or equal to n.

  9. Prediction of the external work of the native heart from the dynamic H-Q curves of the rotary blood pumps during left heart bypass.

    Science.gov (United States)

    Yokoyama, Yoshimasa; Kawaguchi, Osamu; Kitao, Takashi; Kimura, Taro; Steinseifer, Ulrich; Takatani, Setsuo

    2010-09-01

    The ventricular performance is dependent on the drainage effect of rotary blood pumps (RBPs) and the performance of RBPs is affected by the ventricular pulsation. In this study, the interaction between the ventricle and RBPs was examined using the pressure-volume (P-V) diagram of the ventricle and dynamic head pressure-bypass flow (H-Q) curves (H, head pressure: arterial pressure minus ventricular pressure vs. Q, bypass flow) of the RBPs. We first investigated the relationships in a mock loop with a passive fill ventricle, followed by validation in ex vivo animal experiments. An apical drainage cannula with a micro-pressure sensor was especially fabricated to obtain ventricular pressure, while three pairs of ultrasonic crystals placed on the heart wall were used to derive ventricular volume. The mock loop-configured ventricular apical-descending aorta bypass revealed that the external work of the ventricle expressed by the area inside the P-V diagrams (EW(Heart) ) correlated strongly with the area inside dynamic H-Q curves (EW(VAD)), with the coefficients of correlation being R² = 0.869 ∼ 0.961. The results in the mock loop were verified in the ex vivo studies using three Shiba goats (10-25 kg in body weight), showing the correlation coefficients of R² = 0.802 ∼ 0.817. The linear regression analysis indicated that the increase in the bypass flow reduced pulsatility in the ventricle expressed in EW(Heart) as well as in EW(VAD) . Experimental results, both mock loop and animal studies, showed that the interaction between cardiac external work and H-Q performance of RBPs can be expressed by the relationships "EW(Heart) versus EW(VAD) ." The pulsatile nature of the native heart can be expressed in the area underneath the H-Q curves of RBPs EW(VAD) during left heart bypass indicating the status of the level of assistance by RBPs and the native heart function.

  10. A Bovine Hemoglobin-Based Oxygen Carrier as Pump Prime for Cardiopulmonary Bypass: Reduced Systemic Lactic Acidosis and Improved Cerebral Oxygen Metabolism During Low-flow in a Porcine Model

    Science.gov (United States)

    2010-11-10

    TNF-α changed significantly from baseline to completion. Mean creatine kinase was elevated at baseline due to the sample being collected after...NS NS CK, creatine kinase ; CKMB, creatine kinase MB; AST, aspartate aminotransferase; BUN, blood urea nitrogen; IL-6, interleukin 6; TNF-α, tumor...diffusion resistance , and facilitates oxygen delivery to tissue beds (1,2). HBOC-201 is a “high P50” HBOC: the P50 of HBOC-201 is 38 mm Hg compared to 27

  11. 46 CFR 28.815 - Bilge pumps, bilge piping, and dewatering systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Bilge pumps, bilge piping, and dewatering systems. 28... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.815 Bilge pumps, bilge... fixed, self priming, powered, bilge pump, having a minimum capacity rating of 50 gallons per...

  12. Penis Pump

    Science.gov (United States)

    ... claim that they can be used to increase penis size, but there's no evidence that they work for ... circumstances, using a penis pump might help your penis maintain its natural size and shape after prostate surgery or if you ...

  13. Efficient prime counting and the Chebyshev primes

    CERN Document Server

    Planat, Michel

    2011-01-01

    The function $\\epsilon(x)=li(x)-\\pi(x)$ is known to be positive up to the (very large) Skewes' number. Besides, according to Robin's work, the functions $\\epsilon_{\\theta}(x)=li[\\theta(x)]-\\pi(x)$ and $\\epsilon_{\\psi}(x)=li[\\psi(x)]-\\pi(x)$ are positive if and only if Riemann hypothesis (RH) holds (the first and the second Chebyshev function are $\\theta(x)=\\sum_{p \\le x} \\log p$ and $\\psi(x)=\\sum_{n=1}^x \\Lambda(n)$, respectively, $li(x)$ is the logarithmic integral, $\\mu(n)$ and $\\Lambda(n)$ are the M\\"obius and the Von Mangoldt functions). Negative jumps in the above functions $\\epsilon$, $\\epsilon_{\\theta}$ and $\\epsilon_{\\psi}$ may potentially occur only at $x+1 \\in \\mathcal{P}$ (the set of primes). One denotes $j_p=li(p)-li(p-1)$ and one investigates the jumps $j_p$, $j_{\\theta(p)}$ and $j_{\\psi(p)}$. In particular, $j_p1$ for $p<10^{11}$. Besides, $j_{\\psi(p)}<1$ for any odd $p \\in \\mathcal{Ch}$, an infinite set of so-called {\\it Chebyshev primes} with partial list ${109, 113, 139, 181, 197, 199, ...

  14. Multisensory Flavor Priming

    DEFF Research Database (Denmark)

    Dijksterhuis, Garmt Bernard

    2016-01-01

    Flavor is multisensory; several interacting sensory systems-taste, smell, and mouthfeel-together comprise "flavor," making it a cognitively constructed percept rather than a bottom-up sensory one. In this chapter, some of the complications this entails for flavor priming are introduced, along...... with a taxonomy of different priming situations. In food-related applications of flavor, both bottom-up (sensory) as well as top-down (expectations) processes are at play. Most of the complex interactions that this leads to take place outside the awareness of the perceiving subject. A model is presented where...... many, past and current, aspects (sensory, surroundings, social, somatic, sentimental) of a (flavor) perception, together result in the perception of a flavor, its liking. or its choice. This model borrows on ideas from priming, situated/embodied cognition, and (food-related) perception....

  15. Sodium-potassium pump activity in white blood cells from children with an increased risk of developing hypertension--The Odense Schoolchild Study

    DEFF Research Database (Denmark)

    Hansen, H S; Nielsen, J R; Pedersen, K E

    1993-01-01

    . A significant increase in 86rubidium uptake was present in boys as compared to girls. After adjustment for differences in sexual maturation the observed significant difference disappeared. Important correlates of pump activity were height, plasma glucose, and physical fitness. In the training study 10 boys from...... the hypertensive subgroup and 10 boys from the normotensive subgroup were also evaluated after eight months of physical training. A significant fall in 86rubidium uptake was observed. No control group was examined and probably the changes reflect some effects of sexual maturation on cation handling of cells....... These results indicate a significant effect of sexual maturation in capacity of sodium-potassium pump in children....

  16. Flow characteristics in Sarns centrifugal blood pump based on computational fluid dynamics technology%基于CFD技术的Sarns离心式血泵流动特性分析北京生物医学工程

    Institute of Scientific and Technical Information of China (English)

    程云章; 朱莉花; 张伟国

    2012-01-01

    目的应用专业计算流体动力学(computational fluid dynamics,CFD)分析软件FLUENT,对一种具有长短叶片的Sarns离心式血泵的内部流场进行三维数值模拟.方法 利用Solidworks软件对Sarns型血泵进行三维建模,然后对所建模型网格处理,通过选取标准κ-ε湍流模型和SIMPLE算法,具体分析了内部流动状态、压力分布、壁面剪切力等流场特性.结果 结果表明,该离心泵内部流场分布较不匀,叶片及血泵出口处有回流和旋涡现象,剪切力大小基本处于致红细胞破碎的临界状态之下,高转速下剪切力最大,主要分布在叶轮区域,但暴露时间极短,基本满足血液生理要求.结论 该研究为Sarns血泵的进一步优化提供了理论基础.%Objective To simulate the three-dimensional internal flow field of a Sarns blood centrifugal pump with long and short blades by using computational fluid dynamics (CFD) software FLUENT. Methods We used the software Solidworks to build a three-dimensional model and selected the standard κ-ε turbulence model and the SIMPLE algorithm to analyze the flow characteristics of the internal flow status, pressure distribution and wall shear force. Results The analysis result demonstrated that there were several deficiencies in this pump, such as uneven velocity distribution, partial backflow and whirlpool between the blades and near the outlet of the pump. The shear stress distribution was under the critical state of breaking red blood cells and the maximum value of shear stress appeared in the impeller area under high-rotational speed. As the exposure time was short, the shear stress distribution could basically meet the physiological requirements of blood. Conclusions This research offered a theoretic basis for the further optimization of Sarns blood pump.

  17. New Designed Implantable Axial-flow Blood Pump and Its Numerical Prediction Study%植入型轴流血泵设计及其流体性能数值预报

    Institute of Scientific and Technical Information of China (English)

    叶亮; 范慧敏; 洪方文; 周连第; 陈应生; 刘中民

    2011-01-01

    A new designed implantable axial-flow blood pump was introduced. Blood is driven by big-smaU tandem impeller installed in the inner hole of cylinder magnet ofbrushless direct current motor. The inner hole of cylinder magnet will take the shape of the main flow passage while the gap between the inner end of stator and the outer end of cylinder magnet of motor takes the shape of the tributary flow passage. There is no magnets rotor in the main flow passage and more blood flow can pass through it. The gap of tributary flow passage is very small so the efficiency can be increased and the volume and weight of blood pump can be reduced greatly. The outer diameter, length and weight of manufactured implantable axial-flow blood pump are 29.6 mm, 76 mm and 158 g respectively. The impeller can generate 100 mmHg pressure head and 8 L/min flow rate when spinning at 9000 rpm. It has been implanted into some calves in experimental tests. Meanwhile, a mathematical model of simulating theflow of axial-flow blood pump was established. The numerical prediction of performance of implantable axial-flow blood pump may be carried out by combining this mathematical model and Fluent software. The agreement between the numerical predictions and experimental results are satisfactory with the maximum error within 10%.%可植入心室辅助装置(俗称人工心脏)是治疗终末期心衰的有力工具,设计以轴流血泵居多。给出了一种植入型轴流血泵的新颖设升,血液由置于无刷电机圆柱磁钢转子内孔的大、小串列转子驱动,磁钢内孔形成主流道,而电机定子内径和磁钢转子外径间的缝隙形成支流道。这样主流道内没有电机磁钢转子,流道阻碍小面积大,可保证大血量流从主流道通过。支流道间隙小即无刷电机定子线圈和转子磁钢的气隙小,保证了电机的高效率,从而显著减小了轴流血泵整体的体积和重量,设计的轴流血泵外径为29.6mm

  18. Comparison of a New Miniaturized Extracorporeal Membrane Oxygenation System With Integrated Rotary Blood Pump to a Standard System in a Porcine Model of Acute Lung Injury.

    Science.gov (United States)

    Pilarczyk, Kevin; Heckmann, Jens; Lyskawa, Kathrin; Strauß, Andreas; Haake, Nils; Wiese, Ingo; Jakob, Heinz; Kamler, Markus; Pizanis, Nikolaus

    2016-07-01

    Extracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) was developed and compared with a standard ECMO system in a large animal model. Acute lung injury was induced with repeated pulmonary saline lavage in 14 pigs until PaO2 /FiO2 -ratio was ECMO; group 3 (n = 5): vv-ILIAS. Gas exchange, hemodynamics, hemolysis, and coagulation activation were examined over a period of 8 h. No device failed during the observation period. PaCO2 decreased from 59.40 ± 4.14 mm Hg to 48.62 ± 4.50 mm Hg after 1 h in the ILIAS group compared with an improvement of PaCO2 from 48.86 ± 7.45 to 40.10 ± 6.02 in the conventional ECMO group (P = not significant [n.s.]). ARDS-induced respiratory acidosis was controlled promptly with a pH of 7.2 ± 0.1 at baseline increasing to 7.4 ± 0.1 in both study groups after 60 min of ECMO support. Mean carbon dioxide transfer was comparable between the conventional ECMO and ILIAS (211.36 ± 78.39 mL/min vs. 219.99 ± 76.72 mL/min, P = n.s.). PaO2 /FiO2 increased from 118.4 ± 15.5 mm Hg to 179.1 ± 72.4 mm Hg in the ILIAS group compared with an improvement of oxygenation from 107.1 ± 24.9 mm Hg to 179.0 ± 45.7 mm Hg in the standard ECMO group (P = n.s.). Mean oxygen transfer was calculated with 136.09 ± 30.25 mL/min for the ILIAS and 129.05 ± 36.28 mL/min for the standard ECMO. Hemodynamic instability or significant activation of the plasmatic coagulation was not observed. However, hemolysis was significantly higher in the ILIAS group compared with the conventional ECMO. As the ILIAS prototype provided excellent gas exchange with hemodynamic stability comparable with a standard ECMO

  19. Detecting Priming News Events

    CERN Document Server

    Wu, Di; Yu, Jeffrey Xu; Liu, Zheng

    2012-01-01

    We study a problem of detecting priming events based on a time series index and an evolving document stream. We define a priming event as an event which triggers abnormal movements of the time series index, i.e., the Iraq war with respect to the president approval index of President Bush. Existing solutions either focus on organizing coherent keywords from a document stream into events or identifying correlated movements between keyword frequency trajectories and the time series index. In this paper, we tackle the problem in two major steps. (1) We identify the elements that form a priming event. The element identified is called influential topic which consists of a set of coherent keywords. And we extract them by looking at the correlation between keyword trajectories and the interested time series index at a global level. (2) We extract priming events by detecting and organizing the bursty influential topics at a micro level. We evaluate our algorithms on a real-world dataset and the result confirms that ou...

  20. Sums of many primes

    CERN Document Server

    Languasco, Alessandro

    2011-01-01

    Assuming that the Generalized Riemann Hypothesis (GRH) holds, we prove an explicit formula for the number of representations of an integer as a sum of $k\\geq 5$ primes. Our error terms in such a formula improve by some logarithmic factors an analogous result by Friedlander-Goldston.

  1. PrimeFaces blueprints

    CERN Document Server

    Jonna, Sudheer

    2014-01-01

    If you are a Java developer with experience of frontend UI development, and want to take the plunge to develop stunning UI applications with the most popular JSF framework, PrimeFaces, then this book is for you. For those with entrepreneurial aspirations, this book will provide valuable insights into how to utilize successful business models.

  2. On Particles and Primes

    CERN Document Server

    Knill, Oliver

    2016-01-01

    Primes in the two complete associative normed division algebras C and H have affinities with structures seen in the standard model of particle physics. On the integers in the two algebras, there are two equivalence relations: a strong one, related to a U(1) and SU(3) symmetry allowing to permute and switch signs of the coordinates of the integers, as well as a weak relation with origins from units U(1),SU(2) in the algebra. Weak equivalence classes within the strong equivalence classes of odd primes in C case relate to leptons, the inert ones being neutrino like, and the split ones resembling electron-positron pairs. In the H case, for odd primes, the equivalence classes come in groups of two or three, leading to a caricature of hadrons featuring either mesons built by a quark pair or then baryons obtained by quark triplets. We can now list for every rational prime p all these particles and attach fractional charges to its constituents.

  3. Development and in vitro study of miniature implantable axial flow blood pump%植入式微型轴流血泵的研制及体外实验研究

    Institute of Scientific and Technical Information of China (English)

    王玉璇; 张杰民; 施超; 刘晓程

    2009-01-01

    Objective The research of impeller blood pump has been the key point in cardiac surgery and biomedical engineering fields in recent years. To investigate hydrodynamies of self researched and developed mini axial flow pump, parameters of pump were tested on a homemade mimic vitro platform. Methods Hydrodynamics tests were performed in vitro mimic circulation, water and 30% glycerin in water as respeetive circulatory mediator to simulate blood. Results Flow rates can reach 6. 19L/min and 5.08L/min respectively in water and 30% glycerin, when rotation speed was 13000rpm and pressure was 100mmHg. Conclusion Axial flow blood pump has good hydrodynamics to substitute for left ventricle, whieh can meet the demand of assisted circulation in congestive heart failure patients.%目的 近年来,叶轮血泵的研究已经成为心脏外科和生物医学工程领域关注的焦点.通过体外模拟循环实验台对自行研发设计的微型轴流血泵进行测试,探讨血泵的体外流体力学特性.方法 分别利用水及30%甘油水溶液作为循环介质模拟血液在体外模拟循环条件下进行血泵流体力学测试.结果 在血泵转速为13000 rpm,压力为100 mmHg时,分别以水及30%甘油水溶液作为循环介质.其对应流量达到6.19 L/min和5.08 L/min.结论 该轴流血泵的基本流体力学性能良好,其流体力学特性已经完全可以替代左心室功能,满足临床心衰患者辅助循环需求.

  4. An implantable seal-less centrifugal pump with integrated double-disk motor.

    Science.gov (United States)

    Schima, H; Schmallegger, H; Huber, L; Birgmann, I; Reindl, C; Schmidt, C; Roschal, K; Wieselthaler, G; Trubel, W; Losert, U

    1995-07-01

    Thrombus formation and sealing problems at the shaft as well as the compact and efficient design of the driving unit have been major difficulties in the construction of a long-term implantable centrifugal pump. To eliminate the problems of the seal, motor size, and efficiency, two major steps were taken by modifying the Vienna implantable centrifugal pump. First, a special driving unit was developed, in which the permanent magnets of the motor themselves are used for coupling the force into the rotor. Second, the rotor shaft in the pumping chamber was eliminated by adopting a concept recently presented by Ohara. The rotor is supported by 3 pins, which run on a carbon disk, whose concave shape leads to stabilization. The device has the following specifications: size: 65 mm (diameter) by 35 mm (height), 101 cm3; priming volume 30 cm3, 240 g; and a 6-pole brushless double disk DC motor. The required input power of the described prototype is 15 W at 150 mm Hg, 5 L/min (overall eta = 11%), and has an in vitro index of hemolysis (IH) of 0.0046 g/100 L. The test for in vitro thrombus growth exhibited far less thrombus formation in the new design than in designs with axles. In conclusion, the design of a special driving unit and the elimination of the axle led to the construction of a small pump with very low blood traumatization.

  5. Chen's Theorem with Small Primes

    Institute of Scientific and Technical Information of China (English)

    Ying Chun CAI

    2002-01-01

    Let N be a sufficiently large even integer. In this paper it is proved that the equationN = p + P2, p ≤ N0.95,is solvable, where p denotes a prime and P2 denotes an almost prime with at most two prime factors.

  6. Chen's Theorem with Small Primes

    Institute of Scientific and Technical Information of China (English)

    Yingjie LI; Yingchun CAI

    2011-01-01

    Let N be a sufficiently large even integer. Let p denote a prime and P2 denote an almost prime with at most two prime factors. In this paper, it is proved that the equation N - p+ P2 (p ≤ AT0.945) is solvable.

  7. Superficial Priming in Episodic Recognition

    Science.gov (United States)

    Dopkins, Stephen; Sargent, Jesse; Ngo, Catherine T.

    2010-01-01

    We explored the effect of superficial priming in episodic recognition and found it to be different from the effect of semantic priming in episodic recognition. Participants made recognition judgments to pairs of items, with each pair consisting of a prime item and a test item. Correct positive responses to the test item were impeded if the prime…

  8. Masked Repetition Priming Using Magnetoencephalography

    Science.gov (United States)

    Monahan, Philip J.; Fiorentino, Robert; Poeppel, David

    2008-01-01

    Masked priming is used in psycholinguistic studies to assess questions about lexical access and representation. We present two masked priming experiments using MEG. If the MEG signal elicited by words reflects specific aspects of lexical retrieval, then one expects to identify specific neural correlates of retrieval that are sensitive to priming.…

  9. Rhizosphere priming: a nutrient perspective

    Science.gov (United States)

    Rhizosphere priming is the change in decomposition of soil organic matter (SOM) caused by root activity. Rhizosphere priming plays a crucial role in soil carbon (C) dynamics and their response to global climate change. Rhizosphere priming may be affected by soil nutrient availability, but rhizospher...

  10. VENTRICLE ASSIST DEVICE: PAST, PRESENT, AND FUTURE NONPULSATILE PUMPS

    Directory of Open Access Journals (Sweden)

    G. Р. Itkin

    2009-01-01

    Full Text Available The article briefly describes the history of the non-pulsating type blood pumps for ventricular assist circulation and heart-lung machine. Disclosed the main advantages of these pumps before pulsating type, especially for implantable systems development. However, disadvantages of these pumps and the directions of minimize or eliminate ones have shown. Specific examples of our implantable centrifugal and axial pump developments are presented. Declare the ways to further improve the pumps

  11. Cantor Primes as Prime-Valued Cyclotomic Polynomials

    CERN Document Server

    Salas, Christian

    2012-01-01

    Cantor primes are primes p such that 1/p belongs to the middle-third Cantor set. One way to look at them is as base-3 analogues of the famous Mersenne primes, which encompass all base-2 repunit primes, i.e., primes consisting of a contiguous sequence of 1's in base 2 and satisfying an equation of the form p + 1 = 2^q. The Cantor primes encompass all base-3 repunit primes satisfying an equation of the form 2p + 1 = 3^q, and I show that in general all Cantor primes > 3 satisfy a closely related equation of the form 2pK + 1 = 3^q, with the base-3 repunits being the special case K = 1. I use this to prove that the Cantor primes > 3 are exactly the prime-valued cyclotomic polynomials of the form $\\Phi_s(3^{s^j}) \\equiv 1$ (mod 4). Significant open problems concern the infinitude of these, making Cantor primes perhaps more interesting than previously realised.

  12. Pumps; Pumpen

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, H. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft; Hellriegel, E. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft; Pfitzner, G. [Gesellschaft fuer Praktische Energiekunde e.V., Muenchen (Germany). Forschungsstelle fuer Energiewirtschaft

    1994-11-01

    The technical features of commercial pump types are described with regard to their technical, energy-related and economic parameters, and characteristic data are presented in the form of data sheets. This is to provide a basis for a comparative assessment of different technologies and technical variants. The chapter `System specifications` describes the various fields of application of pumps and the resulting specific requirements. The design and function of the different pump types are described in `Technical description`. `System and plant description dscribes the design and adaptation of pumps, i.e. the adaptation of the plant data to the system requirements. `Data compilation` provides a survey of the types and systematics of the compiled data as well as a decision aid for selecting the pumps best suited to the various applications. The `Data sheet` section describes the structure and handling of the data sheets as well as the data contained therein. The data sheets are contained in the apapendix of this report. The section `General analysis` compares typical technical, energy-related and economic characteristics of the different pump types. This is to enable a rough comparison of pump types and to facilitate decisions. The chapter `Example` illustrates the use of the data sheets by means of a selected example. (orig./GL) [Deutsch] Die vorliegende Arbeit hat zum Ziel, Technik seriengefertigter und marktgaengiger Pumpen in typisierter Form hinsichtlich ihrer technischen, energetischen und wirtschaftlichen Parameter zu beschreiben und ihre charakteristischen Kennwerte in Datenblaettern abzubilden. Damit wird ein grundlegendes Instrument fuer die vergleichende Beurteilung unterschiedlicher Techniken bzw. Technikvarianten hinsichtlich energetischer und wirtschaftlicher Kriterien geschaffen. Im Abschnitt `Systemanforderungen` erfolgt die Beschreibung der einzelnen Anwendungsbereiche fuer Pumpen mit den speziellen daraus resultierenden Anforderungen. Der Aufbau und

  13. Semantic priming of familiar songs.

    Science.gov (United States)

    Johnson, Sarah K; Halpern, Andrea R

    2012-05-01

    We explored the functional organization of semantic memory for music by comparing priming across familiar songs both within modalities (Experiment 1, tune to tune; Experiment 3, category label to lyrics) and across modalities (Experiment 2, category label to tune; Experiment 4, tune to lyrics). Participants judged whether or not the target tune or lyrics were real (akin to lexical decision tasks). We found significant priming, analogous to linguistic associative-priming effects, in reaction times for related primes as compared to unrelated primes, but primarily for within-modality comparisons. Reaction times to tunes (e.g., "Silent Night") were faster following related tunes ("Deck the Hall") than following unrelated tunes ("God Bless America"). However, a category label (e.g., Christmas) did not prime tunes from within that category. Lyrics were primed by a related category label, but not by a related tune. These results support the conceptual organization of music in semantic memory, but with potentially weaker associations across modalities.

  14. Subliminal Semantic Priming in Speech

    Science.gov (United States)

    Tillmann, Barbara; Perrin, Fabien

    2011-01-01

    Numerous studies have reported subliminal repetition and semantic priming in the visual modality. We transferred this paradigm to the auditory modality. Prime awareness was manipulated by a reduction of sound intensity level. Uncategorized prime words (according to a post-test) were followed by semantically related, unrelated, or repeated target words (presented without intensity reduction) and participants performed a lexical decision task (LDT). Participants with slower reaction times in the LDT showed semantic priming (faster reaction times for semantically related compared to unrelated targets) and negative repetition priming (slower reaction times for repeated compared to semantically related targets). This is the first report of semantic priming in the auditory modality without conscious categorization of the prime. PMID:21655277

  15. Subliminal semantic priming in speech.

    Directory of Open Access Journals (Sweden)

    Jérôme Daltrozzo

    Full Text Available Numerous studies have reported subliminal repetition and semantic priming in the visual modality. We transferred this paradigm to the auditory modality. Prime awareness was manipulated by a reduction of sound intensity level. Uncategorized prime words (according to a post-test were followed by semantically related, unrelated, or repeated target words (presented without intensity reduction and participants performed a lexical decision task (LDT. Participants with slower reaction times in the LDT showed semantic priming (faster reaction times for semantically related compared to unrelated targets and negative repetition priming (slower reaction times for repeated compared to semantically related targets. This is the first report of semantic priming in the auditory modality without conscious categorization of the prime.

  16. Types of Breast Pumps

    Science.gov (United States)

    ... Devices Consumer Products Breast Pumps Types of Breast Pumps Share Tweet Linkedin Pin it More sharing options ... used for feeding a baby. Types of Breast Pumps There are three basic types of breast pumps: ...

  17. Development of Automatic Monitoring Alarm of Autologous Blood Recoverer Roller Pump Microgap%自体血液回收机滚压泵微量泵距自动监控报警仪的研制

    Institute of Scientific and Technical Information of China (English)

    田勇; 丁巾

    2012-01-01

    Autologous blood recoverer is widely used in surgical operation in recent years. Roller pump is a crucial component of the equipment, and the slot width between rolling axle and pump trough is an important parameter relative to receiving blood quality. In this paper, the automatic monitoring device of rolling and microgap whose processing core was STC12C5A60S2 chip microcomputer was designed by using Flexiforce thin film force transducer as sensing element. In addition, LCD display and alarming functions were provided. With the advantages of small, portable, convenient usage and so on, the instrument is completely suitable for autologous blood recoverer in clinical application process.%自体血液回收机是近年来广泛应用于外科手术的先进仪器.液体滚压泵是自体血液回收机中的关键部件,而其中的滚压轴与泵槽间隙则是关系到血液回收质量等级的重要参数.本文以Flexiforce薄膜压力传感器为感测元件,设计了以STC 12C5A60S2单片机为处理核心的滚压泵微量泵距参数自动监测仪器,并具有液晶显示、超限报警等功能.该仪器体积小、易携带、使用方便,完全适用于自体血液回收机的临床应用.

  18. Effects of high-intensity intermittent priming on physiology and cycling performance.

    Science.gov (United States)

    McIntyre, Jordan P R; Kilding, Andrew E

    2015-01-01

    The pre-event warm-up or "priming" routine for optimising cycling performance is not well-defined or uniform to a specific event. We aimed to determine the effects of varying the intensity of priming on 3 km cycling performance. Ten endurance-trained male cyclists completed four 3 km time-trials (TT) on four separate occasions, each preceded by a different priming strategy including "self-selected" priming and three intermittent priming strategies incorporating 10 min of constant-load cycling followed by 5 × 10 s bouts of varying relative intensity (100% and 150% of peak aerobic power, Wpeak, and all-out priming). The self-selected priming trial (379 ± 44 W) resulted in similar mean power during the 3 km TT to intermittent priming at 100% (376 ± 45 W; -0.7%; unclear) and 150% (374 ± 48 W; -1.5%, unclear) of Wpeak, but significantly greater than all-out priming (357 ± 45 W; -5.8%, almost certainly harmful). Differences between intermittent and self-selected priming existed with regards to heart rate (6.2% to 11.5%), blood lactate (-22.9% to 125%) and VO2 kinetics (-22.9% to 8.2%), but these were not related to performance outcomes. In conclusion, prescribed intermittent priming strategies varying in intensity did not substantially improve 3 km TT performance compared to self-selected priming.

  19. Potential Danger of Pre-Pump Clamping on Negative Pressure-Associated Gaseous Microemboli Generation During Extracorporeal Life Support--An In Vitro Study.

    Science.gov (United States)

    Wang, Shigang; Chin, Brian J; Gentile, Frank; Kunselman, Allen R; Palanzo, David; Ündar, Akif

    2016-01-01

    The objectives of this study were to investigate the relationship between revolution speed of a conventional centrifugal pump and negative pressure at the inlet of the pump by clamping the tubing upstream of the pump, and to verify whether negative pressure leads to gaseous microemboli (GME) production in a simulated adult extracorporeal life support (ECLS) system. The experimental circuit, including a Maquet Rotaflow centrifugal pump and a Medos Hilite 7000 LT polymethyl-pentene membrane oxygenator, was primed with packed red blood cells (hematocrit 35%). Negative pressure was created in the circuit by clamping the tubing upstream of the pump for 10 s, and then releasing the clamp. An emboli detection and classification quantifier was used to record GME volume and count at pre-oxygenator and post-oxygenator sites, and pressure and flow rate data were collected using a custom-based data acquisition system. All trials were conducted at 36°C at revolution speeds of 2000-4000 rpm (500 rpm increment). The flow rates were 1092.5-4708.4 mL/min at the revolution speeds of 2000-4000 rpm. Higher revolution speed generated higher negative pressure at the pre-pump site when clamping the tubing upstream of the pump (-108.3 ± 0.1 to -462.0 ± 0.5 mm Hg at 2000-4000 rpm). Moreover, higher negative pressure was associated with a larger number and volume of GME at pre-oxygenator site after de-clamp (GME count 10,573 ± 271 at pre-oxygenator site at 4000 rpm). The results showed that there was a potential danger of delivering GME to the patient when clamping pre-pump tubing during ECLS using a centrifugal pump. Our results warrant further clinical studies to investigate this phenomenon.

  20. Short term in vivo thrombosis evaluation of FW-Ⅱ axial blood pump for left ventricular assist%FW-Ⅱ型轴流泵短期辅助抗体内血栓形成性能评价

    Institute of Scientific and Technical Information of China (English)

    陈海波; 胡盛寿; 周建业; 孙寒松; 唐跃; 张岩; 柳光茂; 朱晓东

    2011-01-01

    Objective To evaluate in vivo antithrombosis property of optimized FW-Ⅱ axial blood pump and provides evidence for future clinical use.Methods A left ventricle-pump-descending aorta bypass model was established in five healthy sheep (60-70 kg) and the circulation of these sheep was assisted by FW-Ⅱ axial blood pump for 2 weeks.In preoperative and postoperative day 1,2,3,7,10 and 14,blood was drawn from the jugular vein to examine platelet activation and leukocyte-platelet aggregation respectively quantified with Annexin V,CD41/61 and CD14-PE by flow cytometry assays.Immediately after termination of the experiment,FW-Ⅱ axial blood pumps were explanted and each part was inspected for thrombus formation.Macroscopic and histological examinations were checked on heart,brain,kidney and spleen,respectively for thrombosis.Results Compared with preoperative baseline,the number of platelet activation and leukocyte-platelet aggregation reached a peak at postoperative day 2,it retained a high level within 7 days,then gradually decreased,but was still higher than preoperative level at dayl4.According to rotating speed,the number of platelet activation and platelet-leukocyte aggregation were lowest at the speed of 8000 r/min Minus thrombus were found in the front and rear hub of the pump rotor,and there was no thrombus at other components (flow straighter,impeller and pump housing).There were no ischemia and infarction evidences in macroscopic and histological examination of the heart,brain,kidney and spleen.Conclusion FW-II axial blood pump can be used to assist left ventricular circulation for 2 weeks with a satisfactory antithrombosis property.The level of platelet activation and leukocyte-platelet aggregation can be reduced to a lowest level at an optimized pump rotating speed.%目的 对优化设计FW-Ⅱ轴流泵短期辅助的抗血栓性能进行评价,为后期临床应用提供依据.方法 5只60~70 kg成年小尾寒羊,建立心室-泵-降主动脉旁路循

  1. FIELD TRIALS OF NEWLY DEVELOPED POSITIVE DISPLACEMENT SUBMERSIBLE PUMP

    Energy Technology Data Exchange (ETDEWEB)

    Rob Beard

    2003-10-01

    The purpose of this grant was to evaluate under real world conditions the performance of a new type of downhole pump, the hydraulically driven submersible diaphragm pump. This pump is supplied by Pumping Solutions Incorporated, Albuquerque NM. The original scope of the project was to install 10 submersible pumps, and compare that to 10 similar installations of rod pumps. As an operator, the system as tested was not ready for prime time, but has shown the ability to reduce costs, and increase production, if run times can be improved. The PSI group did improve the product and offered excellent service. The latest design appears to be much better, but more test data is needed to show short run life is not a problem. PSI and Beard Oil intend to continue testing the pump with non-government funding. The testing to date did not uncover any fundamental problems that would preclude the widespread use of this pump, and as an operator, I believe that with further improvement and testing, the pump can have a significant impact on stripper well costs. On the positive side, the pump was easy to run, was more power efficient then a rod pump, and is the only submersible that could handle the large quantities of solids typical of the production environment found at the Weber field and in CMB production. The product shows much promise for the future, and with continued design and testing, this type of submersible pump has the potential to become the standard of the industry.

  2. Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study.

    Science.gov (United States)

    Gill, Martin C; Dando, Hayden; John, Dittmer

    2010-09-01

    The occurrence of gaseous microemboli (GME) within the extracorporeal membrane oxygenation circuit is largely overlooked, as are methods to ameliorate this occurrence. We aimed to determine if the air handling capability of the Quadrox D oxygenator was dependent upon whether it was used in conjunction with a centrifugal or roller pump; and if application of a Pall air eliminating filter (AEF) would prevent circuit air introduction from intravenous infusions. Using a blood primed circuit 1 mL of air was infused pre pump. GME were quantified post pump and post oxygenator using the EDAC Quantifier. Trials were conducted at 1 and 2 L/min flow. To prevent GME recirculation a Capiox SX18 was used in circuit with negative pressure applied to its oxygenator; an EDAC cuvette distal to this device quantified GME recirculation. Following air infusion, 3-5 minute data recordings were carried out for each trial. Separate trials were carried out for centrifugal and roller pumps, and for each flow rate. The process was then repeated following the application of the AEF to the air infusion line. More GME were detected post Quadrox D when the centrifugal pump was used in comparison to the roller pump at 1 L/min (p < .05), and 2 L/min (p = .05). A greater volume of air was detected post Quadrox D when used in conjunction with the centrifugal device at 1 L/min (p < or = .05), and 2 L/min (p < or = .05). Application of the AEF resulted in zero GME detected at any circuit location. The results of this study confirm that a greater total count and volume of GME are detected distal to the Quadrox D when used in conjunction with a Rotaflow centrifugal pump. Application of a Pall AEF to infusion and drug lines can prevent air introduction from this source.

  3. On the fractal distribution of primes and prime-indexed primes by the binary image analysis

    Science.gov (United States)

    Cattani, Carlo; Ciancio, Armando

    2016-10-01

    In this paper, the distribution of primes and prime-indexed primes (PIPs) is studied by mapping primes into a binary image which visualizes the distribution of primes. These images show that the distribution of primes (and PIPs) is similar to a Cantor dust, moreover the self-similarity with respect to the order of PIPs (already proven in Batchko (2014)) can be seen as an invariance of the binary images. The index of primes plays the same role of the scale for fractals, so that with respect to the index the distribution of prime-indexed primes is characterized by the self-similarity alike any other fractal. In particular, in order to single out the scale dependence, the PIPs fractal distribution will be evaluated by limiting to two parameters, fractal dimension (δ) and lacunarity (λ), that are usually used to measure the fractal nature. Because of the invariance of the corresponding binary plots, the fractal dimension and lacunarity of primes distribution are invariant with respect to the index of PIPs.

  4. Difference between consecutive primes

    Institute of Scientific and Technical Information of China (English)

    贾朝华

    1995-01-01

    Suppose that B is a sufficiently large positive constant, ε is a sufficiently small positive constant, X and N are sufficiently large. It is mainly proved that i) for the positive integers n, Xprime number; ii) if A = N1/2+s, then the even numbers in the interval (N, N+A), except for 0(Alog-B N) values, are all Goldbach numbers.

  5. Psychotherapy Augmentation through Preconscious Priming

    OpenAIRE

    Borgeat, François; O’Connor, Kieron; Amado, Danielle; St-Pierre-Delorme, Marie-Ève

    2013-01-01

    Objective: To test the hypothesis that repeated preconscious (masked) priming of personalized positive cognitions could augment cognitive change and facilitate achievement of patients’ goals following a therapy. Methods: Twenty social phobic patients (13 women) completed a 36-weeks study beginning by 12 weeks of group behavioral therapy. After the therapy, they received 6 weeks of preconscious priming and 6 weeks of a control procedure in a randomized cross-over design. The Priming conditi...

  6. Transposed-Letter Priming Effects with Masked Subset Primes: A Re-Examination of the "Relative Position Priming Constraint"

    Science.gov (United States)

    Stinchcombe, Eric J.; Lupker, Stephen J.; Davis, Colin J.

    2012-01-01

    Three experiments are reported investigating the role of letter order in orthographic subset priming (e.g., "grdn"-GARDEN) using both the conventional masked priming technique as well as the sandwich priming technique in a lexical decision task. In all three experiments, subset primes produced priming with the effect being considerably…

  7. Transposed-Letter Priming Effects with Masked Subset Primes: A Re-Examination of the "Relative Position Priming Constraint"

    Science.gov (United States)

    Stinchcombe, Eric J.; Lupker, Stephen J.; Davis, Colin J.

    2012-01-01

    Three experiments are reported investigating the role of letter order in orthographic subset priming (e.g., "grdn"-GARDEN) using both the conventional masked priming technique as well as the sandwich priming technique in a lexical decision task. In all three experiments, subset primes produced priming with the effect being considerably…

  8. Jet pump noise analysis for BWRs

    Energy Technology Data Exchange (ETDEWEB)

    Castillo-Duran, R.; Hernandez-lopez, H.; Ortiz-Villafuerte, J.; Alonso-Vargas, G. [Instituto Nacional de Investigaciones Nucleares, Mexico (Mexico); Calleros-Micheland, G. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Veracruz (Mexico)

    2004-07-01

    The use of noise analysis for detection of BWR component malfunction is a powerful tool in determining abnormal operation conditions, during the life of a nuclear power plant. Since the eighties, several nuclear reactors have reported problems related with jet pumps and recirculation loops. The NRC (Nuclear Regulatory Commission) recommends performing periodic monitoring to individual pressure drop jet pumps, to prevent structural failure. In this work, noise analysis methods are used for detection of jet pumps abnormal operation conditions in a BWR. Power signals obtained from the backup process computer of a BWR are analyzed with a home-developed software, called NOISE, for noise diagnostic of power signals. The computer program takes individual signals from the tabular report of the process computer. The normalized power spectral density (NPSD) is then obtained, using a Prime Factor Algorithm to calculate the Fast Fourier Transform. The NPSD of the jet pumps pressure drop, of Unit 2 of the Laguna Verde Nuclear Power Plant, showed a noticeable change in jet pump 6 during 2003, considering the period from the startup test to operation during 2003. This abnormal condition was due to that the jet pump throat was partially blocked. The noise analysis methodology is shown to be a useful tool for malfunction detection, and could be applied to create a data bank for monitoring the dynamic behavior of BWR jet pumps. (authors)

  9. Neuroimaging correlates of negative priming.

    Science.gov (United States)

    Steel, C; Haworth, E J; Peters, E; Hemsley, D R; Sharma, T; Gray, J A; Pickering, A; Gregory, L; Simmons, A; Bullmore, E T; Williams, S C

    2001-11-16

    Many theoretical accounts of selective attention and memory retrieval include reference to active inhibitory processes, such as those argued to underlie the negative priming effect. fMRI was used in order to investigate the areas of cortical activation associated with Stroop interference, Stroop facilitation and Stroop negative priming tasks. The most significant activation within the negative priming task was within the inferior parietal lobule, left temporal lobe and frontal lobes. Areas of cortical activation are discussed with reference to theoretical accounts of the negative priming effect.

  10. [Insulin pump therapy: for whom and why?].

    Science.gov (United States)

    Saraheimo, Markku; Honkasalo, Mikko; Miettinen, Marko

    2013-01-01

    Insulin pump therapy utilizes continuous infusion for the basic supply of insulin. As compared with multiple daily injections, pump therapy enables a clearly more precise targeting of the insulin therapy with respect to both time and quantity. This is important for insulin-sensitive patients such as small children, adults susceptible to hypoglycemia, or diabetics, whose blood glucose level exhibits a clear-cut elevation in the small hours (the dawn phenomenon). Also a diabetic with a high HbA1c and a good motivation for treatment may significantly benefit from the pump. Insulin pump therapy requires commitment to good self-monitoring from the diabetic patient.

  11. Prime mover progress

    Energy Technology Data Exchange (ETDEWEB)

    Hennagir, T.

    1995-05-01

    Manufacturers continue to upgrade fluidized bed and steam technologies to meet more stringent emission, efficiency and service challenges from global power market customers. Offshore, suppliers are being pushed to provide quality, low-cost production and significant local competitive presence in nearly all international markets. The ability to meet customer and regulatory demands for emissions across different global market segments remains a priority for prime mover suppliers as they develop environmental technical improvements. Products initially developed for the more stringent European regulations are now finding a market in the US. In developing countries, demand continues for utility-size boiler products, but pollution control equipment costs remain a parallel consideration. Industry improvements to steam cycle equipment, namely turbines, continue to reap benefits in terms of efficiency and operational flexibility. Boiler and steam manufacturers` response to global markets remains right on target as product development strategies are constantly adjusted and analyzed to reach an optimum marketing mix. Innovation and advances in prime mover power equipment technology remain a mainstay of suppliers` ability to meet the needs of a changing, competitive clientele.

  12. Prime injections and quasipolarities

    Directory of Open Access Journals (Sweden)

    Octavio Alberto Agustín-Aquino

    2014-05-01

    Full Text Available Let $p$ be a prime number. Consider the injection\\[ \\iota:\\mathbb{Z}/n\\mathbb{Z}\\to\\mathbb{Z}/pn\\mathbb{Z}:x\\mapsto px, \\]and the elements $e^{u}.v:=(u,v\\in \\mathbb{Z}/n\\mathbb{Z}\\rtimes \\mathbb{Z}/n\\mathbb{Z}^{\\times}$ and$e^{w}.r:=(w,r\\in \\mathbb{Z}/pn \\mathbb{Z}\\rtimes \\mathbb{Z}/pn\\mathbb{Z}^{\\times}$. Suppose that $e^{u}.v\\in\\mathbb{Z}/n\\mathbb{Z}\\rtimes \\mathbb{Z}/n\\mathbb{Z}^{\\times}$ is seen as an automorphism of $\\mathbb{Z}/n\\mathbb{Z}$defined by $e^{u}.v(x=vx+u$; then $e^{u}.v$ is a \\emph{quasipolarity} if it is an involution without fixed points.In this brief note we give an explicit formula for the number of quasipolarities of $\\mathbb{Z}/n\\mathbb{Z}$ interms of the prime decomposition of $n$, and we prove sufficient conditions such that $(e^{w}.r\\circ \\iota=\\iota\\circ (e^{u}.v$, where $e^{w}.r$ and $e^{u}.v$ are quasipolarities.

  13. Bomba sangüínea espiral: concepção, desenvolvimento e aplicação clínica de projeto original Spiral blood pump: conception, development and clinical application of the original project

    Directory of Open Access Journals (Sweden)

    Jarbas J. Dinkhuysen

    2007-06-01

    danos excessivos aos elementos figurados do sangue.INTRODUCTION: This paper addresses an original project that encompasses the conception, development and clinical application of a helical bypass pump called the Spiral Pump, that uses the association of centrifugal and axial propulsion forces based de the Archimedes principle. This project has obtained a Brazilian Patent and an International Preliminary Report, defining it as an invention. METHODS: The aim of this work was to evaluate the hemodynamic capacity and the impact of its application on blood cells by means of experimental in vitro tests, including hydrodynamic efficiency, effect on hemolysis and flow visualization. Moreover, in vivo experimental tests were carried out on lambs that were submitted to cardiopulmonary bypass for six hours and in 43 patients submitted to heart bypass surgery using the Spiral Pump. RESULTS: When the rotor-plastic casing gap was 1.5mm, the flow generated was nearly 9 L/min, the pressure was greater than 400 mmHg at 1500 rpm, and the normalized hemolytic indexes were not greater than 0.0375 g/100L in high-flow and pressure conditions. Additionally, by the flow visualization techniques, stagnation was not seen inside the pump nor was turbulence identified at the entrance or exit of the pump, or at the ends of the spindles. In the in vivo tests using cardiopulmonary bypasses for 6 hours in lambs, the pump maintained adequate pressure rates and the free hemoglobin levels ranged between 16.36 mg% and 44.90 mg%. Evaluating the results of the 43 patients who used this pump in heart bypass operations we observed that the free hemoglobin ranged from 9.34 mg% before to 44.16 mg% after surgery, the serum fibrinogen was from 236.65 mg% to 547.26mg%, platelet blood count from 152,465 to 98,139 and the lactic dehydrogenase from 238.12mg% to 547.26mg%. The Activated Coagulation Time was close to 800 seconds during the bypass. CONCLUSION: The Spiral Pump was very effective in generating adequate

  14. Investigating Home Primes and Their Families

    Science.gov (United States)

    Herman, Marlena; Schiffman, Jay

    2014-01-01

    The process of prime factor splicing to generate home primes raises opportunity for conjecture and exploration. The notion of "home primes" is relatively new in the chronicle of mathematics. Heleen (1996-97) first described a procedure called "prime factor splicing" (PFS). The exploration of home primes is interesting and…

  15. Primes, Geometry and Condensed Matter

    Directory of Open Access Journals (Sweden)

    Al Rabeh R. H.

    2009-07-01

    Full Text Available Fascination with primes dates back to the Greeks and before. Primes are named by some "the elementary particles of arithmetic" as every nonprime integer is made of a unique set of primes. In this article we point to new connections between primes, geometry and physics which show that primes could be called "the elementary particles of physics" too. This study considers the problem of closely packing similar circles/spheres in 2D/3D space. This is in effect a discretization process of space and the allowable number in a pack is found to lead to some unexpected cases of prime configurations which is independent of the size of the constituents. We next suggest that a non-prime can be considered geometrically as a symmetric collection that is separable (factorable into similar parts- six is two threes or three twos for example. A collection that has no such symmetry is a prime. As a result, a physical prime aggregate is more difficult to split symmetrically resulting in an inherent stability. This "number/physical" stability idea applies to bigger collections made from smaller (prime units leading to larger stable prime structures in a limitless scaling up process. The distribution of primes among numbers can be understood better using the packing ideas described here and we further suggest that differing numbers (and values of distinct prime factors making a nonprime collection is an important factor in determining the probability and method of possible and subsequent disintegration. Disintegration is bound by energy conservation and is closely related to symmetry by Noether theorems. Thinking of condensed matter as the packing of identical elements, we examine plots of the masses of chemical elements of the periodic table, and also those of the elementary particles of physics, and show that prime packing rules seem to play a role in the make up of matter. The plots show convincingly that the growth of prime numbers and that of the masses of

  16. Primes, Geometry and Condensed Matter

    Directory of Open Access Journals (Sweden)

    Al Rabeh R. H.

    2009-07-01

    Full Text Available Fascination with primes dates back to the Greeks and before. Primes are named by some “the elementary particles of arithmetic” as every nonprime integer is made of a unique set of primes. In this article we point to new connections between primes, geometry and physics which show that primes could be called “the elementary particles of physics” too. This study considers the problem of closely packing similar circles / spheres in 2D / 3D space. This is in effect a discretization process of space and the allowable num- ber in a pack is found to lead to some unexpected cases of prime configurations which is independent of the size of the constituents. We next suggest that a non-prime can be considered geometrically as a symmetric collection that is separable (factorable into similar parts- six is two threes or three twos for example. A collection that has no such symmetry is a prime. As a result, a physical prime aggregate is more difficult to split symmetrically resulting in an inherent stability. This “number / physical” stability idea applies to bigger collections made from smaller (prime units leading to larger sta- ble prime structures in a limitless scaling up process. The distribution of primes among numbers can be understood better using the packing ideas described here and we further suggest that differing numbers (and values of distinct prime factors making a nonprime collection is an important factor in determining the probability and method of possible and subsequent disintegration. Disintegration is bound by energy conservation and is closely related to symmetry by Noether theorems. Thinking of condensed matter as the packing of identical elements, we examine plots of the masses of chemical elements of the periodic table, and also those of the elementary particles of physics, and show that prime packing rules seem to play a role in the make up of matter. The plots show con- vincingly that the growth of prime numbers and that

  17. Custom Unit Pump Development for the EVA PLSS

    Science.gov (United States)

    Schuller, Michael; Kurwitz, Cable; Little, Frank; Oinuma, Ryoji; Larsen, Ben; Goldman, Jeff; Reinis, Filip; Trevino, Luis

    2010-01-01

    This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, seal-less, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion, and restart capability under both ambient and vacuum conditions. The pump operated at 40 to 240 lbm/hr flow rate, 35 to 100 oF pump temperature, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test.

  18. Pump characteristics and applications

    CERN Document Server

    Volk, Michael

    2013-01-01

    Providing a wealth of information on pumps and pump systems, Pump Characteristics and Applications, Third Edition details how pump equipment is selected, sized, operated, maintained, and repaired. The book identifies the key components of pumps and pump accessories, introduces the basics of pump and system hydraulics as well as more advanced hydraulic topics, and details various pump types, as well as special materials on seals, motors, variable frequency drives, and other pump-related subjects. It uses example problems throughout the text, reinforcing the practical application of the formulae

  19. Almost primes in short intervals

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In this paper,we prove that the short interval(x-x101/232,x] contains at least an almost prime P2 for sufficiently large x,where P2 denotes an integer having at most two prime factors counted with multiplicity.

  20. Immediate Priming and Cognitive Aftereffects

    Science.gov (United States)

    Huber, David E.

    2008-01-01

    Three forced-choice perceptual word identification experiments tested the claim that transitions from positive to negative priming as a function of increasing prime duration are due to cognitive aftereffects. These aftereffects are similar in nature to perceptual aftereffects that produce a negative image due to overexposure and habituation to a…

  1. PrimeFaces beginner's guide

    CERN Document Server

    Reddy, K Siva Prasad

    2013-01-01

    A guide for beginner's with step-by-step instructions and an easy-to-follow approach.PrimeFaces Beginners Guide is a simple and effective guide for beginners, wanting to learn and implement PrimeFaces in their JSF-based applications. Some basic JSF and jQuery skills are required before you start working through the book.

  2. Repetition priming from moving faces.

    Science.gov (United States)

    Lander, Karen; Bruce, Vicki

    2004-06-01

    Recent experiments have suggested that seeing a familiar face move provides additional dynamic information to the viewer, useful in the recognition of identity. In four experiments, repetition priming was used to investigate whether dynamic information is intrinsic to the underlying face representations. The results suggest that a moving image primes more effectively than a static image, even when the same static image is shown in the prime and the test phases (Experiment 1). Furthermore, when moving images are presented in the test phase (Experiment 2), there is an advantage for moving prime images. The most priming advantage is found with naturally moving faces, rather than with those shown in slow motion (Experiment 3). Finally, showing the same moving sequence at prime and test produced more priming than that found when different moving sequences were shown (Experiment 4). The results suggest that dynamic information is intrinsic to the face representations and that there is an advantage to viewing the same moving sequence at prime and test.

  3. Rhizosphere priming: a nutrient perspective.

    Science.gov (United States)

    Dijkstra, Feike A; Carrillo, Yolima; Pendall, Elise; Morgan, Jack A

    2013-01-01

    Rhizosphere priming is the change in decomposition of soil organic matter (SOM) caused by root activity. Rhizosphere priming plays a crucial role in soil carbon (C) dynamics and their response to global climate change. Rhizosphere priming may be affected by soil nutrient availability, but rhizosphere priming itself can also affect nutrient supply to plants. These interactive effects may be of particular relevance in understanding the sustained increase in plant growth and nutrient supply in response to a rise in atmospheric CO2 concentration. We examined how these interactions were affected by elevated CO2 in two similar semiarid grassland field studies. We found that an increase in rhizosphere priming enhanced the release of nitrogen (N) through decomposition of a larger fraction of SOM in one study, but not in the other. We postulate that rhizosphere priming may enhance N supply to plants in systems that are N limited, but that rhizosphere priming may not occur in systems that are phosphorus (P) limited. Under P limitation, rhizodeposition may be used for mobilization of P, rather than for decomposition of SOM. Therefore, with increasing atmospheric CO2 concentrations, rhizosphere priming may play a larger role in affecting C sequestration in N poor than in P poor soils.

  4. Rhizosphere priming: a nutrient perspective

    Directory of Open Access Journals (Sweden)

    Feike Auke Dijkstra

    2013-07-01

    Full Text Available Rhizosphere priming is the change in decomposition of soil organic matter (SOM caused by root activity. Rhizosphere priming plays a crucial role in soil carbon (C dynamics and their response to global climate change. Rhizosphere priming may be affected by soil nutrient availability, but rhizosphere priming itself can also affect nutrient supply to plants. These interactive effects may be of particular relevance in understanding the sustained increase in plant growth and nutrient supply in response to a rise in atmospheric CO2 concentration. We examined how these interactions were affected by elevated CO2 in two similar semiarid grassland field studies. We found that an increase in rhizosphere priming enhanced the release of nitrogen (N through decomposition of a larger fraction of SOM in one study, but not in the other. We postulate that rhizosphere priming may enhance N supply to plants in systems that are N limited, but that rhizosphere priming may not occur in systems that are phosphorus (P limited. Under P limitation, rhizodeposition may be used for mobilisation of P, rather than for decomposition of SOM. Therefore, with increasing atmospheric CO2 concentrations, rhizosphere priming may play a larger role in affecting C sequestration in N poor than in P poor soils.

  5. Priming Macho Attitudes and Emotions.

    Science.gov (United States)

    Beaver, Erik D.; And Others

    1992-01-01

    Investigated the effects of reading one of four priming stimuli stories (control, consenting sex, rape, or family) on males' evaluations of, and emotional reactions to, two videotaped date-rape scenarios. Results supported the concepts of a macho personality and revealed interactive effects for both the rape and family prime. (RJM)

  6. Attentional priming releases crowding.

    Science.gov (United States)

    Kristjánsson, Arni; Heimisson, Pétur Rúnar; Róbertsson, Gunnar Freyr; Whitney, David

    2013-10-01

    Views of natural scenes unfold over time, and objects of interest that were present a moment ago tend to remain present. While visual crowding places a fundamental limit on object recognition in cluttered scenes, most studies of crowding have suffered from the limitation that they typically involved static scenes. The role of temporal continuity in crowding has therefore been unaddressed. We investigated intertrial effects upon crowding in visual scenes, showing that crowding is considerably diminished when objects remain constant on consecutive visual search trials. Repetition of both the target and distractors decreases the critical distance for crowding from flankers. More generally, our results show how object continuity through between-trial priming releases objects that would otherwise be unidentifiable due to crowding. Crowding, although it is a significant bottleneck on object recognition, can be mitigated by statistically likely temporal continuity of the objects. Crowding therefore depends not only on what is momentarily present, but also on what was previously attended.

  7. Exodus: Prime Mover

    Science.gov (United States)

    Bauer, Nikkol; Conwell, Pete; Johnson, Matt; Shields, Wendy; Thornton, Tim; Tokarz, Rob; Mcmanus, Rich

    1992-01-01

    The Exodus Prime Mover is an overnight package delivery aircraft designed to serve the Northern Hemisphere of Aeroworld. The preliminary design goals originated from the desire to produce a large profit. The two main driving forces throughout the design process were first to reduce the construction man-hours by simplifying the aircraft design, thereby decreasing the total production cost of the aircraft. The second influential factor affecting the design was minimizing the fuel cost during cruise. The lowest fuel consumption occurs at a cruise velocity of 30 ft/s. Overall, it was necessary to balance the economic benefits with the performance characteristics in order to create a profitable product that meets all specified requirements and objectives.

  8. Sequential experiments with primes

    CERN Document Server

    Caragiu, Mihai

    2017-01-01

    With a specific focus on the mathematical life in small undergraduate colleges, this book presents a variety of elementary number theory insights involving sequences largely built from prime numbers and contingent number-theoretic functions. Chapters include new mathematical ideas and open problems, some of which are proved in the text. Vector valued MGPF sequences, extensions of Conway’s Subprime Fibonacci sequences, and linear complexity of bit streams derived from GPF sequences are among the topics covered in this book. This book is perfect for the pure-mathematics-minded educator in a small undergraduate college as well as graduate students and advanced undergraduate students looking for a significant high-impact learning experience in mathematics.

  9. 46 CFR 28.820 - Fire pumps, fire mains, fire hydrants, and fire hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fire pumps, fire mains, fire hydrants, and fire hoses... REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.820 Fire pumps, fire mains, fire hydrants, and fire hoses. (a) Each vessel must be equipped with a self-priming, power driven fire...

  10. Relation of Mitochondrial DNA Copy Number in Peripheral Blood to Postoperative Atrial Fibrillation After Isolated Off-Pump Coronary Artery Bypass Grafting.

    Science.gov (United States)

    Zhang, Jian; Xu, Shu; Xu, Yinli; Liu, Yu; Li, Zhi; Zhang, Yuji; Jin, Yan; Xue, Xiaodong; Wang, Huishan

    2017-02-01

    Oxidative stress has been considered to be an important factor contributing to postoperative atrial fibrillation (PoAF). Mitochondrial DNA (mtDNA) copy number in peripheral blood has been found to be associated with a patient's oxidative stress. Therefore, we sought to determine whether there was association between mtDNA copy number and the onset of atrial fibrillation. mtDNA copy numbers were measured using the quantitative real-time polymerase chain reaction in peripheral blood from 485 consecutive patients with sinus rhythm undergoing coronary artery bypass grafting. The blood was collected before surgery. In the cohort, the incidence of PoAF was 20.8% (101/485). The mean mtDNA copy number was significantly higher in patents with PoAF than in those with sinus rhythm (36.43 vs 16.63, p copy number could predict PoAF with good sensitivity and specificity (area under the curve = 0.814, cutoff = 20.91, sensitivity = 70.3%, specificity = 80.2%, p copy number was shown to be a significant independent risk factor for PoAF (odds ratio = 10.01, p copy number and malondialdehyde in patients with PoAF (r = 0.449, p = 0.01). In conclusion, we showed that elevated mtDNA copy number in peripheral blood is associated with PoAF. Further investigation is needed to validate mtDNA copy number as a predictive biomarker for PoAF and to explore its potential role in arrhythmogenesis. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Paper pump for passive and programmable transport.

    Science.gov (United States)

    Wang, Xiao; Hagen, Joshua A; Papautsky, Ian

    2013-01-01

    In microfluidic systems, a pump for fluid-driving is often necessary. To keep the size of microfluidic systems small, a pump that is small in size, light-weight and needs no external power source is advantageous. In this work, we present a passive, simple, ultra-low-cost, and easily controlled pumping method based on capillary action of paper that pumps fluid through conventional polymer-based microfluidic channels with steady flow rate. By using inexpensive cutting tools, paper can be shaped and placed at the outlet port of a conventional microfluidic channel, providing a wide range of pumping rates. A theoretical model was developed to describe the pumping mechanism and aid in the design of paper pumps. As we show, paper pumps can provide steady flow rates from 0.3 μl/s to 1.7 μl/s and can be cascaded to achieve programmable flow-rate tuning during the pumping process. We also successfully demonstrate transport of the most common biofluids (urine, serum, and blood). With these capabilities, the paper pump has the potential to become a powerful fluid-driving approach that will benefit the fielding of microfluidic systems for point-of-care applications.

  12. Priming semantico e museografia / Semantic priming and museography

    Directory of Open Access Journals (Sweden)

    Annalisa Banzi

    2012-05-01

    Full Text Available Il priming è una tipologia di memoria implicita che facilita l’apprendimento di stimoli di diversa natura (stimoli visivi, semantici, etc.. Un allestimento museale che adotti strumenti basati sul priming potrebbe aiutare il pubblico a selezionare i contenuti relativi agli oggetti esposti. In questo articolo viene descritta l’applicazione del priming semantico allo spazio museale. Questa operazione in prima battutta potrebbe essere letta come una mancanza di fiducia nelle capacità cognitive del visitatore nel discriminare il significato delle informazioni. In realtà è una forma di sostegno per aiutare il visitatore a sviluppare gradualmente una propria metodologia di approccio ai contenuti proposti nel museo. Grazie al priming, il pubblico riceve una serie di stimoli che possono aiutare a costituire la base delle proprie conoscenze in ambito storico-artistico ed essere il punto di partenza sul quale costruire un metodo critico.   Many psychological aspects such as motivation, emotion, and attention, affect human learning. Among these, priming triggers and tunes implicit memory processes. Hence the goal of this paper is to check whether semantic priming can be used as an effective tool to design a supportive museum environment where people can easily learn. Moreover, the resulting stronger and more persistent memories could encourage museum visitors to learn more and better, and to develop a method to “read” the artworks. After a brief overview of current models of semantic priming, practical and theoretical issues are considered and discussed.

  13. Clinical use of centrifugal pumps and the roller pump in open heart surgery: a comparative evaluation.

    Science.gov (United States)

    Yoshikai, M; Hamada, M; Takarabe, K; Okazaki, Y; Ito, T

    1996-06-01

    Centrifugal pumps have been used widely as the main pump in open heart surgery to reduce damage to blood elements and to reduce the activation of the coagulation system. The purpose of this study was the evaluation and comparison of the effects of two types of centrifugal pumps and of one type of roller pump on blood elements, the coagulation system, complements, and immunoglobulins. Two types of centrifugal pumps (Lifestream; St. Jude Medical, Chelmsford, Massachusetts; and BP-80: Medtronic, BioMedicus, Inc., Eden Prairie, Minnesota, U.S.A.) and one roller pump (Mera Co.) were used separately as the main pump for cardiopulmonary bypass (CPB) in 29 patients. Platelet counts, lactate dehydrogenase, antithrombin III, thrombin-antithrombin complex (TAT), complements (C3, C4, and CH50) and immunoglobulins G, A, and M values were measured before and after CPB and compared. Values, except those for TAT, showed no significant difference among the three groups. The TAT values increased less in each of the centrifugal pump groups than in the roller pump group. This finding suggests that thrombin synthesis might be suppressed by the use of a centrifugal pump.

  14. LMFBR with booster pump in pumping loop

    Science.gov (United States)

    Rubinstein, H.J.

    1975-10-14

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.

  15. Prospective randomized clinical study of arterial pumps used for routine on pump coronary bypass grafting.

    Science.gov (United States)

    Keyser, Andreas; Hilker, Michael K; Diez, Claudius; Philipp, Alois; Foltan, Maik; Schmid, Christof

    2011-05-01

    In a number of studies, centrifugal blood pumps--in comparison with roller pumps--have been shown to attenuate trauma to blood components. Nevertheless, the impact of these results on the postoperative course needs to be discussed controversially. In a prospective randomized study, 240 consecutive adult patients underwent elective myocardial revascularization with cardiopulmonary bypass employing five different pumps (Roller, Avecor, Sarns, Rotaflow, Bio-Medicus). We analyzed clinical course, blood loss, damage of blood components, and impairment of the hemostatic system. The study population was homogenous with respect to age, gender, myocardial function, and operative data. No differences were found with respect to time of ventilation, duration of intensive care stay, hospitalization, and laboratory data. The choice of arterial pump during standard extracorporeal bypass for elective coronary artery bypass grafting is no matter of concern.

  16. Heat pump technology

    CERN Document Server

    Von Cube, Hans Ludwig; Goodall, E G A

    2013-01-01

    Heat Pump Technology discusses the history, underlying concepts, usage, and advancements in the use of heat pumps. The book covers topics such as the applications and types of heat pumps; thermodynamic principles involved in heat pumps such as internal energy, enthalpy, and exergy; and natural heat sources and energy storage. Also discussed are topics such as the importance of the heat pump in the energy industry; heat pump designs and systems; the development of heat pumps over time; and examples of practical everyday uses of heat pumps. The text is recommended for those who would like to kno

  17. [The design of bionic left ventricular auxiliary pump].

    Science.gov (United States)

    Jin, Henglin; Hu, Xiaobing; Du, Lei

    2015-01-01

    This paper reports a novel design of bionic left ventricular auxiliary pump, and the characteristic is that elastic diaphragm of pump driven by hydraulic, having smooth, reliable blood supply, can prevent blood clots, can use the flow sensor, pressure sensor detection showing the blood pressure and blood volume at the inlet and outlet of the pump. The pump can go with heart rate synchronization or asynchronous auxiliary by the R wave of human body's ECG. The design goal is realization of bionic throb. Through the animal experiment, the blood pressure waveforms are close to expectations, stable flow can stroke according to the set value, which prove that the pump can meet the requirement for heart disease patients for bionic left ventricular assistant.

  18. Optical coding theory with Prime

    CERN Document Server

    Kwong, Wing C

    2013-01-01

    Although several books cover the coding theory of wireless communications and the hardware technologies and coding techniques of optical CDMA, no book has been specifically dedicated to optical coding theory-until now. Written by renowned authorities in the field, Optical Coding Theory with Prime gathers together in one volume the fundamentals and developments of optical coding theory, with a focus on families of prime codes, supplemented with several families of non-prime codes. The book also explores potential applications to coding-based optical systems and networks. Learn How to Construct

  19. Dry vacuum pumps

    Science.gov (United States)

    Sibuet, R.

    2008-05-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R&D/industries, merits over conventional pumps and future growth scope will be discussed.

  20. Ovation Prime Real-Time

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Ovation Prime Real-Time (OPRT) product is a real-time forecast and nowcast model of auroral power and is an operational implementation of the work by Newell et...

  1. No priming for global motion in crowding.

    Science.gov (United States)

    Pavan, Andrea; Gall, Martin G; Manassi, Mauro; Greenlee, Mark W

    2015-01-01

    There is psychophysical evidence that low-level priming, e.g., from oriented gratings, as well as high-level semantic priming, survives crowding. We investigated priming for global translational motion in crowded and noncrowded conditions. The results indicated that reliable motion priming occurs in the noncrowded condition, but motion priming does not survive crowding. Crowding persisted despite variations in the direction of the flankers with respect to the prime's direction. Motion priming was still absent under crowding when 85% of the flankers moved in the same direction as the prime. Crowding also persisted despite variations in the speed of the flankers relative to the prime even when the flankers' speed was four times slower than the speed of the prime. However, a priming effect was evident when the prime's spatial location was precued and its distance to the flankers increased, suggesting a release from crowding. These results suggest that transient attention induced by precueing the spatial location of the prime may improve subjects' ability to discriminate its direction. Spatial cueing could act to decrease the integration field, thereby diminishing the influence of nearby distracters. In an additional experiment in which we used fewer flankers, we found a priming effect under conditions in which the interelement distance varied between flankers and prime. Overall, the results suggest that motion priming is strongly affected by crowding, but transient attention can partially retrieve such facilitation.

  2. Continued fractions constructed from prime numbers

    CERN Document Server

    Wolf, Marek

    2010-01-01

    We give 50 digits values of the simple continued fractions whose denominators are formed from a) prime numbers, b) twin primes, c) primes of the form m^2+1 and Mersenne primes. All these continued fractions belong to the set of measure zero of exceptions to the Khinchin Theorem.

  3. Psychotherapy augmentation through preconscious priming

    Directory of Open Access Journals (Sweden)

    Francois eBorgeat

    2013-03-01

    Full Text Available Objective: To test the hypothesis that repeated preconscious (masked priming of personalized positive cognitions could augment cognitive change and facilitate achievement of patients’ goals following a therapy.Methods: Twenty social phobic patients (13 women completed a 36 weeks study beginning by 12 weeks of group behavioural therapy. After the therapy, they received 6 weeks of preconscious priming and 6 weeks of a control procedure in a randomized cross-over design. The Priming condition involved listening twice daily with a passive attitude to a recording of individualized formulations of appropriate cognitions and attitudes masked by music. The Control condition involved listening to an indistinguishable recording where the formulations had been replaced by random numbers. Changes in social cognitions were measured by the Social Interaction Self Statements Test (SISST.Results: Patients improved following therapy. The Priming procedure was associated with increased positive cognitions and decreased negative cognitions on the SISST while the Control procedure was not. The Priming procedure induced more cognitive change when applied immediately after the group therapy. Conclusion: An effect of priming was observed on social phobia related cognitions in the expected direction. This self administered addition to a therapy could be seen as an augmentation strategy.

  4. Centrifugal pump handbook

    CERN Document Server

    Pumps, Sulzer

    2010-01-01

    This long-awaited new edition is the complete reference for engineers and designers working on pump design and development or using centrifugal pumps in the field. This authoritative guide has been developed with access to the technical expertise of the leading centrifugal pump developer, Sulzer Pumps. In addition to providing the most comprehensive centrifugal pump theory and design reference with detailed material on cavitation, erosion, selection of materials, rotor vibration behavior and forces acting on pumps, the handbook also covers key pumping applications topics and operational

  5. Locus of single-prime negative priming: the role of perceptual form.

    Science.gov (United States)

    Chao, Hsuan-Fu

    2013-07-01

    Single-prime negative priming refers to the phenomenon in which after a single prime word is briefly presented, repeating it as the probe target results in a delay in responding to the target. The present study investigated the locus of this negative priming effect. Experiment 1 showed that repeating the identity of the prime produced a negative priming effect but merely repeating the response of the prime did not. Experiment 2 showed that the negative priming effect transformed into positive priming when the probe distractor was absent. Experiments 3 and 4 further revealed that single-prime negative priming was observed when the perceptual form was repeated. Taken together, these results suggest that single-prime negative priming involves a perceptual locus.

  6. Response Priming with More or Less Biological Movements as Primes.

    Science.gov (United States)

    Eckert, David; Bermeitinger, Christina

    2016-07-01

    Response priming in general is a suitable tool in cognitive psychology to investigate motor preactivations. Typically, compatibility effects reflect faster reactions in cases in which prime and target suggest the same response (i.e., compatible trials) compared with cases in which prime and target suggest opposite responses (i.e., incompatible trials). With moving dots that were horizontally aligned, Bermeitinger (2013) found a stable pattern of results: with short SOAs, faster responses in compatible trials were found; with longer SOAs up to 250 ms, faster responses in incompatible trials were found. It is unclear whether these results are specific to the special motion used therein or whether it generalizes to other motions. We therefore used other motions realized by arrangements of dots. In four experiments, we tested point-light displays (biological coherent walkers vs. less biological scrambled/split displays) as primes. In two experiments, eye gaze motions realized by moving dots representing irises and pupils (i.e., biological) versus the same motion either without surrounding face information or integrated in an abstract line drawing (i.e., less biological) were used. We found overall large positive compatibility effects with biological motion primes and also positive-but smaller-compatibility effects with less biological motion primes. Most important, also with very long SOAs (up to 1320 ms), we did not find evidence for negative compatibility effects. Thus, the pattern of positive-followed-by-negative-compatibility effects found in Bermeitinger (2013) seems to be specific to the materials used therein, whereas response priming in general seems an applicable tool to study motion perception.

  7. Comparative hemolysis study of clinically available centrifugal pumps.

    Science.gov (United States)

    Naito, K; Suenaga, E; Cao, Z L; Suda, H; Ueno, T; Natsuaki, M; Itoh, T

    1996-06-01

    Centrifugal pumps have become important devices for cardiopulmonary bypass and circulatory assistance. Five types of centrifugal pumps are clinically available in Japan. To evaluate the blood trauma caused by centrifugal pumps, a comparative hemolysis study was performed under identical conditions. In vitro hemolysis test circuits were constructed to operate the BioMedicus BP-80 (Medtronic, BioMedicus), Sarns Delphin (Sarns/3M Healthcare), Isoflow (St. Jude Medical [SJM]), HPM-15 (Nikkiso), and Capiox CX-SP45 (Terumo). The hemolysis test loop consisted of two 1.5 m lengths of polyvinyl chloride tubing with a 3/8-inch internal diameter, a reservoir with a sampling port, and a pump head. All pumps were set to flow at 6 L/min against the total pressure head of 120 mm Hg. Experiments were conducted simultaneously for 6 h at room temperature (21 degrees C) with fresh bovine blood. Blood samples for plasma-free hemoglobin testing were taken, and the change in temperature at the pump outlet port was measured during the experiment. The mean pump rotational speeds were 1,570, 1,374, 1,438, 1,944, and 1,296 rpm, and the normalized indexes of hemolysis were 0.00070, 0.00745, 0.00096, 0.00066, 0.00090 g/100 L for the BP-80, Sarns, SJM, Nikkiso, and Terumo pumps, respectively. The change in temperature at the pump outlet port was the least for the Nikkiso pump (1.8 degrees C) and the most with the SJM pump (3.8 degrees C). This study showed that there is no relationship between the pump rotational speed (rpm) and the normalized index of hemolysis in 5 types of centrifugal pumps. The pump design and number of impellers could be more notable factors in blood damage.

  8. Sequential Stereotype Priming: A Meta-Analysis.

    Science.gov (United States)

    Kidder, Ciara K; White, Katherine R; Hinojos, Michelle R; Sandoval, Mayra; Crites, Stephen L

    2017-08-01

    Psychological interest in stereotype measurement has spanned nearly a century, with researchers adopting implicit measures in the 1980s to complement explicit measures. One of the most frequently used implicit measures of stereotypes is the sequential priming paradigm. The current meta-analysis examines stereotype priming, focusing specifically on this paradigm. To contribute to ongoing discussions regarding methodological rigor in social psychology, one primary goal was to identify methodological moderators of the stereotype priming effect-whether priming is due to a relation between the prime and target stimuli, the prime and target response, participant task, stereotype dimension, stimulus onset asynchrony (SOA), and stimuli type. Data from 39 studies yielded 87 individual effect sizes from 5,497 participants. Analyses revealed that stereotype priming is significantly moderated by the presence of prime-response relations, participant task, stereotype dimension, target stimulus type, SOA, and prime repetition. These results carry both practical and theoretical implications for future research on stereotype priming.

  9. The Intervenor Effect in Masked Priming: How Does Masked Priming Survive across an Intervening Word?

    Science.gov (United States)

    Forster, Kenneth I.

    2009-01-01

    Four masked priming experiments are reported investigating the effect of inserting an unrelated word between the masked prime and the target. When the intervening word is visible, identity priming is reduced to the level of one-letter-different form priming, but form priming is largely unaffected. However, when the intervening word is itself…

  10. On the Control of Single-Prime Negative Priming: The Effects of Practice and Time Course

    Science.gov (United States)

    Chao, Hsuan-Fu

    2009-01-01

    Single-prime negative priming refers to the phenomenon wherein repetition of a prime as the probe target results in delayed response. Sometimes this effect has been found to be contingent on participants' unawareness of the primes, and sometimes it has not. Further, sometimes this effect has been found to be eliminated when the prime could predict…

  11. On the Control of Single-Prime Negative Priming: The Effects of Practice and Time Course

    Science.gov (United States)

    Chao, Hsuan-Fu

    2009-01-01

    Single-prime negative priming refers to the phenomenon wherein repetition of a prime as the probe target results in delayed response. Sometimes this effect has been found to be contingent on participants' unawareness of the primes, and sometimes it has not. Further, sometimes this effect has been found to be eliminated when the prime could predict…

  12. The Intervenor Effect in Masked Priming: How Does Masked Priming Survive across an Intervening Word?

    Science.gov (United States)

    Forster, Kenneth I.

    2009-01-01

    Four masked priming experiments are reported investigating the effect of inserting an unrelated word between the masked prime and the target. When the intervening word is visible, identity priming is reduced to the level of one-letter-different form priming, but form priming is largely unaffected. However, when the intervening word is itself…

  13. The occurrence of prime numbers revisited

    OpenAIRE

    Ernesto Tapia Moore; José Tapia Yañez

    2016-01-01

    Based on an arithmetical and autocatalytic approach, the authors propose a solution for the occurrence of prime numbers. Exact arithmetical calculations are provided for: the closest prime to any given positive integer (or any number of bigger or smaller primes from that integer); the quantity of prime (and composite) numbers between 1 and any positive integer; the quantity of prime (and composite) numbers between any two positive integers.

  14. The occurrence of prime numbers revisited

    Directory of Open Access Journals (Sweden)

    Ernesto Tapia Moore

    2016-03-01

    Full Text Available Based on an arithmetical and autocatalytic approach, the authors propose a solution for the occurrence of prime numbers. Exact arithmetical calculations are provided for: the closest prime to any given positive integer (or any number of bigger or smaller primes from that integer; the quantity of prime (and composite numbers between 1 and any positive integer; the quantity of prime (and composite numbers between any two positive integers.

  15. The Affective Regulation of Cognitive Priming

    OpenAIRE

    Storbeck, Justin; Clore, Gerald L.

    2008-01-01

    Semantic and affective priming are classic effects observed in cognitive and social psychology, respectively. We discovered that affect regulates such priming effects. In Experiment 1, positive and negative moods were induced prior to one of three priming tasks; evaluation, categorization, or lexical decision. As predicted, positive affect led to both affective priming (evaluation task) and semantic priming (category and lexical decision tasks). However, negative affect inhibited such effects...

  16. Early dynamics of the semantic priming shift

    Science.gov (United States)

    Lavigne, Frédéric; Chanquoy, Lucile; Dumercy, Laurent; Vitu, Françoise

    2013-01-01

    Semantic processing of sequences of words requires the cognitive system to keep several word meanings simultaneously activated in working memory with limited capacity. The real- time updating of the sequence of word meanings relies on dynamic changes in the associates to the words that are activated. Protocols involving two sequential primes report a semantic priming shift from larger priming of associates to the first prime to larger priming of associates to the second prime, in a range of long SOAs (stimulus-onset asynchronies) between the second prime and the target. However, the possibility for an early semantic priming shift is still to be tested, and its dynamics as a function of association strength remain unknown. Three multiple priming experiments are proposed that cross-manipulate association strength between each of two successive primes and a target, for different values of short SOAs and prime durations. Results show an early priming shift ranging from priming of associates to the first prime only to priming of strong associates to the first prime and all of the associates to the second prime. We investigated the neural basis of the early priming shift by using a network model of spike frequency adaptive cortical neurons (e.g., Deco & Rolls, 2005), able to code different association strengths between the primes and the target. The cortical network model provides a description of the early dynamics of the priming shift in terms of pro-active and retro-active interferences within populations of excitatory neurons regulated by fast and unselective inhibitory feedback. PMID:23717346

  17. System Thermal Model for the S-Prime Thermionic Reactor

    Science.gov (United States)

    Arx, Alan V. Von

    1994-07-01

    A model has been developed which numerically simulates heat transfer and flow characteristics of the thermal-hydraulic loop of the S-PRIME thermionic reactor. The components for which detailed models have been included are: the thermionic fuel elements (TFEs), heat pipe panels, flow loop and pumps. The reactor start-up operation was then modeled from zero to full power. It includes modelling of the melting of the heat pipe working fluid as well as correlations for the performance of the thermionic cells. The results show that there is stable operation during this period.

  18. FIELD TRIALS OF NEWLY DEVELOPED POSITIVE DISPLACEMENT SUBMERSIBLE PUMP

    Energy Technology Data Exchange (ETDEWEB)

    Rob Beard; Leland Traylor

    2002-12-01

    The purpose of this grant was to evaluate under real world conditions the performance of a new type of downhole pump, the hydraulically driven submersible diaphragm pump. This pump is supplied by Pumping Solutions Incorporated, Albuquerque NM. The original scope of the project was to install 10 submersible pumps, and compare that to 10 similar installations of rod pumps. As an operator, the system as tested was not ready for prime time. The PSI group did improve the product and offered excellent service. The latest design appears to be much better, but more test data is needed to show short run life is not a problem. This product should continue to be developed; the testing did not uncover any fundamental problems that would preclude it's widespread use. On the positive side, the pump was easy to run, was more power efficient then a rod pump, and is the only submersible that could handle the large quantities of solids typical of CBM production. The product shows much promise for the future, and with continued design and testing, this type of submersible pump has the potential to become the standard of the industry.

  19. Alternative backing up pump for turbomolecular pumps

    Science.gov (United States)

    Myneni, Ganapati Rao

    2003-04-22

    As an alternative to the use of a mechanical backing pump in the application of wide range turbomolecular pumps in ultra-high and extra high vacuum applications, palladium oxide is used to convert hydrogen present in the evacuation stream and related volumes to water with the water then being cryo-pumped to a low pressure of below about 1.e.sup.-3 Torr at 150.degree. K. Cryo-pumping is achieved using a low cost Kleemenco cycle cryocooler, a somewhat more expensive thermoelectric cooler, a Venturi cooler or a similar device to achieve the required minimization of hydrogen partial pressure.

  20. Peripheral blood T lymphocytes from asthmatic patients are primed for enhanced expression of interleukin (IL)-4 and IL-5 mRNA : associations with lung function and serum IgE

    NARCIS (Netherlands)

    Borger, P; Ten Hacken, NHT; Vellenga, E; Kauffman, HF; Postma, DS

    Background The TH2-like cytokines interleukin (IL)-4 and IL-5 play a pivotal role in airway wall inflammation in asthma and these cytokines are increased in peripheral blood and bronchoalveolar lavage fluid from asthmatic patients. It is unclear why specifically TH2-like cytokines are increased in

  1. The Change of Hemorheology of 920 Patients in Prime of Life%920例青壮年患者血液流变学的改变

    Institute of Scientific and Technical Information of China (English)

    占葆娥

    2002-01-01

    The change of Hemorheology index was analysed between 920 patients in prime of lifeand 500 healthy crowds. There were different changes of hemorheology index in every patient in prime oflife with different symptom. Therefore we consider changes of hemorheology index of diversified blood sys-tem diseases begin to change in prime of life. It is proved that the prime of life is the important phase inwhich blood start to curdle and blood system diseases occur. The important prophylactic measures is to payattention to changes of hemorheology index.

  2. Large electromagnetic pumps. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kilman, G.B.

    1976-01-01

    The development of large electromagnetic pumps for the liquid metal heat transfer systems of fission reactors has progressed for a number of years. Such pumps are now planned for fusion reactors and solar plants as well. The Einstein-Szilard (annular) pump has been selected as the preferred configuration. Some of the reasons that electromagnetic pumps may be preferred over mechanical pumps and why the annular configuration was selected are discussed. A detailed electromagnetic analysis of the annular pump, based on slug flow, is presented. The analysis is then used to explore the implications of large size and power on considerations of electromagnetic skin effect, geometric skin effect and the cylindrical geometry.

  3. Priming and Habituation for Faces: Individual Differences and Inversion Effects

    Science.gov (United States)

    Rieth, Cory A.; Huber, David E.

    2010-01-01

    Immediate repetition priming for faces was examined across a range of prime durations in a threshold identification task. Similar to word repetition priming results, short duration face primes produced positive priming whereas long duration face primes eliminated or reversed this effect. A habituation model of such priming effects predicted that…

  4. Priming and Habituation for Faces: Individual Differences and Inversion Effects

    Science.gov (United States)

    Rieth, Cory A.; Huber, David E.

    2010-01-01

    Immediate repetition priming for faces was examined across a range of prime durations in a threshold identification task. Similar to word repetition priming results, short duration face primes produced positive priming whereas long duration face primes eliminated or reversed this effect. A habituation model of such priming effects predicted that…

  5. Italy's Prime Minister visits CERN

    CERN Document Server

    Stefania Pandolfi

    2015-01-01

    On Tuesday, 7 July 2015, the Prime Minister of the Italian Republic, Matteo Renzi, visited CERN. He was accompanied by a delegation that included Italy's Minister for Education, University and Research, Stefania Giannini.   From left to right: Fernando Ferroni, President of the Istituto Nazionale di Fisica Nucleare (INFN); Sergio Bertolucci, CERN Director for Research and Scientific Computing; Stefania Giannini, Italy's Minister of Education, University and Research; Matteo Renzi, Prime Minister of the Italian Republic; Fabiola Gianotti, CERN Director-General Designate; Rolf Heuer, CERN Director-General.   The Prime Minister was welcomed by members of the CERN Management together with former CERN Director-General and Senator for Life of the Italian Republic, Carlo Rubbia. After a brief general introduction to CERN’s activities by Rolf Heuer, the Italian delegation visited LHC Point 1. After a tour of the ATLAS control room, they donned helmets to visit th...

  6. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction rela...... to a part of the tube. The invention further relates to a method for creating a flow of a fluid within an at least partly flexible tube by means of a pump element as mentioned above.......The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...

  7. Instant PrimeFaces starter

    CERN Document Server

    Hlavats, Ian

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. Instant Primefaces Starter is a fast-paced, introductory guide designed to give you all the information you need to start using Primfaces, instantly.Instant PrimeFaces Starter is great for developers looking to get started quickly with PrimeFaces. It's assumed that you have some JSF experience already, as well as familiarity with other Java technologies such as CDI and JPA and an understanding of MVC principles, object-relational mapping (ORM),

  8. Proton pump inhibitors

    Science.gov (United States)

    Proton pump inhibitors (PPIs) are medicines that work by reducing the amount of stomach acid made by ... Proton pump inhibitors are used to: Relieve symptoms of acid reflux, or gastroesophageal reflux disease (GERD). This ...

  9. Retrograde autologous priming in cardiopulmonary bypass in adult patients: effects on blood transfusion and hemodilution Perfusato autólogo retrógrado no circuito de circulação extracorpórea em pacientes adultos: efeitos sobre a hemodiluição e transfusão de sangue

    Directory of Open Access Journals (Sweden)

    Ricardo Vieira Reges

    2011-12-01

    Full Text Available INTRODUCTION: Retrograde autologous priming (RAP is a cardiopulmonary bypass (CPB method, at low cost. Previous studies have shown that this method reduces hemodilution and blood transfusions needs through increased intra-operative hematocrit. OBJECTIVE: To evaluate RAP method, in relation to standard CPB (crystalloid priming, in adult patients. METHODS: Sixty-two patients were randomly allocated to two groups: 1 Group RAP (n = 27 of patients operated using the RAP and; 2 Control group of patients operated using CPB standard crystalloid method (n = 35. The RAP was performed by draining crystalloid prime from the arterial and venous lines, before CPB, into a collect recycling bag. The main parameters analyzed were: 1 CPB hemodynamic data; 2 Hematocrit and hemoglobin values; 3 The need for blood transfusions. RESULTS: It was observed statistically significant fewer transfusions during surgery and reduced CPB hemodilution using RAP. The CPB hemodynamic values were similar, observing a tendency to use lower CPB flows in the RAP group patients. CONCLUSION: This investigation was designed to be a small-scale pilot study to evaluate the effects of RAP, which were demonstrated concerning the CPB hemodilution and blood transfusions.INTRODUÇÃO: Perfusato autólogo retrógrado (PAR é uma técnica de circulação extracorpórea (CEC com baixos custos. Estudos anteriores demonstraram que esta técnica reduz a hemodiluição e a necessidade de transfusões de sangue por meio do aumento do hematócrito intraoperatório. OBJETIVO: Avaliar técnica de PAR em relação à CEC técnica padrão (perfusato cristaloide em pacientes adultos. MÉTODOS: Sessenta e dois pacientes foram aleatoriamente alocados em dois grupos: 1 Grupo PAR (n = 27, constituído por pacientes operados utilizando a técnica de PAR e; 2 Grupo Controle, constituído por pacientes operados utilizando técnica padrão de CEC com cristaloides (n = 35. A PAR foi realizada drenando-se o perfusato

  10. Pump for Saturated Liquids

    Science.gov (United States)

    Elliott, D. G.

    1986-01-01

    Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.

  11. Characteristic of Rings. Prime Fields

    Directory of Open Access Journals (Sweden)

    Schwarzweller Christoph

    2015-12-01

    Full Text Available The notion of the characteristic of rings and its basic properties are formalized [14], [39], [20]. Classification of prime fields in terms of isomorphisms with appropriate fields (ℚ or ℤ/p are presented. To facilitate reasonings within the field of rational numbers, values of numerators and denominators of basic operations over rationals are computed.

  12. Erythrocyte Fragment Count Predicts Hemolysis in Roller Pumps

    Institute of Scientific and Technical Information of China (English)

    FAN Jun-qiang; XU Shi-wei; CHEN Fang; DING Min-jun

    2007-01-01

    Hemolysis in blood pumps has been measured by various in vitro test methods, in which normalized index of hemolysis (NIH) was established. As NIH is complicated and difficult to calculate, erythrocyte fragment count is proposed in the present study to predict hemolysis in roller pumps. Methods: Five paired in vitro tests wereconducted using the POLYSTAN pediatric pump(group A) and COBE pump(group B). Ten whole blood samples (400 ml ) were circled in the roller pump for 16 h. Erythrocyte fragments count and plasma-free hemoglobin (FHb) were measured before pumping and every two hours through circulation after four-hour-pumping. The morphological changes of erythrocyte were observed by scanning electron microscope. Results: The two groups' EFC and FHb levels were increased linearly during a long duration of pumping and linear regression of erythrocyte fragments count and plasma-free hemoglobin were correlated. Conclusion: Erythrocyte fragments count could be used as an index in evaluating the in vitro hemolytic properties of blood pumps.

  13. A microfluidic two-pump system inspired by liquid feeding in mosquitoes

    Science.gov (United States)

    Marino, Andrew; Goad, Angela; Stremler, Mark; Socha, John; Jung, Sunghwan

    Mosquitoes feed on nectar and blood using a two-pump system in the head-a smaller cibarial pump in line with a larger a pharyngeal pump, with a valve in between. To suck, mosquitoes transport the liquid (which may be a multi-component viscous fluid, blood) through a long micro-channel, the proboscis. In the engineering realm, microfluidic devices in biomedical applications, such as lab-on-a-chip technology, necessitate implementing a robust pump design to handle clogging and increase flow control compared to a single-pump system. In this talk, we introduce a microfluidic pump design inspired by the mosquito's two-pump system. The pumping performance (flow rate) in presence of impurities (air bubbles, soft clogs) is quantified as a function of phase difference and volume expansion of the pumps, and the elasticity of the valve.

  14. Competition Effects in Phonological Priming: The Role of Mismatch Position between Primes and Targets

    Science.gov (United States)

    Dufour, Sophie; Peereman, Ronald

    2009-01-01

    In three experiments, we examined lexical competition effects using the phonological priming paradigm in a shadowing task. Experiments 1A and 1B showed that an inhibitory priming effect occurred when the primes mismatched the targets on the last phoneme (/bagar/-/bagaj/). In contrast, a facilitatory priming effect was observed when the primes…

  15. Sandwich Priming: A Method for Overcoming the Limitations of Masked Priming by Reducing Lexical Competitor Effects

    Science.gov (United States)

    Lupker, Stephen J.; Davis, Colin J.

    2009-01-01

    An orthographically similar masked nonword prime facilitates responding in a lexical decision task (Forster & Davis, 1984). Recently, this masked priming paradigm has been used to evaluate models of orthographic coding--models that attempt to quantify prime-target similarity. One general finding is that priming effects often do not occur when…

  16. Affective Priming with Associatively Acquired Valence

    Science.gov (United States)

    Aguado, Luis; Pierna, Manuel; Saugar, Cristina

    2005-01-01

    Three experiments explored the effect of affectively congruent or incongruent primes on evaluation responses to positive or negative valenced targets (the "affective priming" effect). Experiment 1 replicated the basic affective priming effect with Spanish nouns: reaction time for evaluative responses (pleasant/unpleasant) were slower on…

  17. Structural Priming and Second Language Learning

    Science.gov (United States)

    Shin, Jeong-Ah; Christianson, Kiel

    2012-01-01

    Structural priming (or syntactic priming) is a speaker's tendency to reuse the same structural pattern as one that was previously encountered (Bock, 1986). This study investigated (a) whether the implicit learning processes involved in long-lag structural priming lead to differential second language (L2) improvement in producing two structural…

  18. Affective Priming with Auditory Speech Stimuli

    Science.gov (United States)

    Degner, Juliane

    2011-01-01

    Four experiments explored the applicability of auditory stimulus presentation in affective priming tasks. In Experiment 1, it was found that standard affective priming effects occur when prime and target words are presented simultaneously via headphones similar to a dichotic listening procedure. In Experiment 2, stimulus onset asynchrony (SOA) was…

  19. Affective priming with auditory speech stimuli

    NARCIS (Netherlands)

    Degner, J.

    2011-01-01

    Four experiments explored the applicability of auditory stimulus presentation in affective priming tasks. In Experiment 1, it was found that standard affective priming effects occur when prime and target words are presented simultaneously via headphones similar to a dichotic listening procedure. In

  20. Bol loops of odd prime exponent

    CERN Document Server

    Foguel, Tuval

    2009-01-01

    Although any finite Bol loop of odd prime exponent is solvable, we show there exist such Bol loops with trivial center. We also construct finitely generated, infinite, simple Bruck loops of odd prime exponent for sufficiently large primes. This shows that the Burnside problem for Bruck loops has a negative answer.

  1. Affective Priming with Auditory Speech Stimuli

    Science.gov (United States)

    Degner, Juliane

    2011-01-01

    Four experiments explored the applicability of auditory stimulus presentation in affective priming tasks. In Experiment 1, it was found that standard affective priming effects occur when prime and target words are presented simultaneously via headphones similar to a dichotic listening procedure. In Experiment 2, stimulus onset asynchrony (SOA) was…

  2. Affective priming with auditory speech stimuli

    NARCIS (Netherlands)

    Degner, J.

    2011-01-01

    Four experiments explored the applicability of auditory stimulus presentation in affective priming tasks. In Experiment 1, it was found that standard affective priming effects occur when prime and target words are presented simultaneously via headphones similar to a dichotic listening procedure. In

  3. Structural Priming and Second Language Learning

    Science.gov (United States)

    Shin, Jeong-Ah; Christianson, Kiel

    2012-01-01

    Structural priming (or syntactic priming) is a speaker's tendency to reuse the same structural pattern as one that was previously encountered (Bock, 1986). This study investigated (a) whether the implicit learning processes involved in long-lag structural priming lead to differential second language (L2) improvement in producing two structural…

  4. Clinical evaluation of the centrifugal pump in open heart surgery: a comparative study of different pumps.

    Science.gov (United States)

    Takarabe, K; Yoshikai, M; Murayama, J; Hamada, M; Ito, T

    1997-07-01

    The centrifugal pump is now widely used in open heart surgery for its clinical benefits related to the blood elements and the coagulation system. The purpose of this study was to compare the clinical performances of and the outcomes offered by 4 types of centrifugal pumps. For each pump, we investigated the effects on the blood elements, coagulation system, complements, and immunoglobulins during open heart surgery. Four types of centrifugal pumps were used: the HPM-15 (Nikkiso Co.), the Capiox (Terumo Co.), the Lifestream (St. Jude Medical Co.), and the BP-80 (Medtronic, BioMedicus Co.). The platelet count, lactate dehydrogenase (LDH), antithrombin III (AT III), thrombin-antithrombin complex (TAT), complements (C3, C4, and CH50), and immunoglobulins (IgG, IgA, and IgM) were measured before and after cardiopulmonary bypass (CPB). The platelet count was decreased more significantly by the HPM-15 than by any of the other pumps. The other parameters showed no difference among the 4 pumps. In clinical use, each of the 4 types of centrifugal pumps was safe.

  5. Diophantine Approximation with Two Primes and One Square of Prime

    Institute of Scientific and Technical Information of China (English)

    LI Wei-ping; WANG Tian-ze

    2012-01-01

    We show that if λ1,λ2,λ3 are non-zero real numbers,not all of the same sign,η is real and λ1/λ2 is irrational,then there are infinitely many ordered triples of primes (p1,p2,p3) for which |λ1p1 + λ2p2 + λ3P23 +η| < (maxpj)-1/40 (log maxpj)4.

  6. Open-cycle vapor compression heat pump system

    Energy Technology Data Exchange (ETDEWEB)

    Becker, F.E.

    1983-06-01

    Waste energy in the form of low pressure waste steam and low grade waste heat can be efficiently recovered and upgraded to high pressure steam by means of an open-cycle steam heat pump system. Thermo Electron has developed a steam heat pump system. A description of the system highlights the rotary screw compressor, the gas engine prime mover, the speed increaser, and the control system. The amount of energy saved by the system is dependent on the performance of the prime mover as well as the compressor. Energy savings of 40 to 70 percent are predicted. A demonstration system was installed at Monsanto in Indian Orchard, Massachusetts. Energy savings of over 63% compared to current steam generation efficiency is expected.

  7. Tight coupling between positive and reversed priming in the masked prime paradigm

    OpenAIRE

    Boy, Frederic; Sumner, Petroc

    2010-01-01

    When associations between certain visual stimuli and particular actions are learnt, those stimuli become capable of automatically and unconsciously activating their associated action plans. Such sensorimotor priming is assumed to be fundamental for efficient responses, and can be reliably measured in masked prime studies even when the primes are not consciously perceived. However, when the delay between prime and target is increased, reversed priming effects are often found instead (the negat...

  8. French Prime Minister tours CERN

    CERN Multimedia

    Anaïs Schaeffer

    2012-01-01

    On 30 July, Jean-Marc Ayrault, the Prime Minister of the French Republic, and Geneviève Fioraso, the Minister of Higher Education and Research, visited the Laboratory.   After being met by the Director-General at LHC Point 5, they visited the CMS control centre and experiment cavern, and got a glimpse of the LHC tunnel at Point 5. The visit ended with a round-table discussion with French and other international members of CERN’s scientific community. During the discussion, the Prime Minister reaffirmed that “support for fundamental research has to be maintained, and France must continue to invest in education, research and innovation.” He also paid tribute to CERN's role in international cooperation, which he qualified as “a fine example of science without borders.”

  9. Controllability, Bezoutian and relative primeness

    Directory of Open Access Journals (Sweden)

    B. N. Datta

    1980-01-01

    Full Text Available Let f(x and g(x be two polynomials of degree n. Then it is well-known that the Bezoutian matrix Bfg associated with f(x and g(x is nonsingular if and only if f(x and g(x are relatively prime. We give an alternative proof of this result. The proof is based on a result on controllability derived in this note.

  10. Affective Priming Caused by Lying

    Directory of Open Access Journals (Sweden)

    Megumi Sato

    2011-10-01

    Full Text Available Typically, arousal increases when telling a lie, as indicated in psychophysiological studies about lie detection. But the emotional valence induced by lying is unknown, though intuition indicates that it may be negative. Indeed, the Electrodermal Activity (EDA, used in such studies, only shows arousal changes during an emotional response. In this study, we examined the emotional valence induced by lying using two tasks. First, in the deceptive task, participants answered “no” to every question regarding the nature of displayed playing cards. Therefore, they told a lie about specific cards. During the task, their EDA was recorded. Secondly, in the figure estimation task, they assessed pictures by “like” or “dislike” after looking at playing cards visibly or subliminally as prime stimuli. We expected them to tend to estimate figures by “dislike” when cards relevant to deception were previously shown. This would mean that an affective priming effect due to telling a lie happened. Actually, this effect was found only when prime stimuli were displayed visibly. This result suggests that lying per se induces negative emotions even without motivation or punishment due to lying. Furthermore, we found that such effect was more blatant in participants whose EDA changes were salient while lying.

  11. KAPAO Prime: Design and Simulation

    Science.gov (United States)

    McGonigle, Lorcan; Choi, P. I.; Severson, S. A.; Spjut, E.

    2013-01-01

    KAPAO (KAPAO A Pomona Adaptive Optics instrument) is a dual-band natural guide star adaptive optics system designed to measure and remove atmospheric aberration over UV-NIR wavelengths from Pomona College’s telescope atop Table Mountain. We present here, the final optical system, KAPAO Prime, designed in Zemax Optical Design Software that uses custom off-axis paraboloid mirrors (OAPs) to manipulate light appropriately for a Shack-Hartman wavefront sensor, deformable mirror, and science cameras. KAPAO Prime is characterized by diffraction limited imaging over the full 81” field of view of our optical camera at f/33 as well as over the smaller field of view of our NIR camera at f/50. In Zemax, tolerances of 1% on OAP focal length and off-axis distance were shown to contribute an additional 4 nm of wavefront error (98% confidence) over the field of view of our optical camera; the contribution from surface irregularity was determined analytically to be 40nm for OAPs specified to λ/10 surface irregularity (632.8nm). Modeling of the temperature deformation of the breadboard in SolidWorks revealed 70 micron contractions along the edges of the board for a decrease of 75°F when applied to OAP positions such displacements from the optimal layout are predicted to contribute an additional 20 nanometers of wavefront error. Flexure modeling of the breadboard due to gravity is on-going. We hope to begin alignment and testing of KAPAO Prime in Q1 2013.

  12. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Greene, R.H.; Casada, D.A.; Ayers, C.W. [and others

    1995-08-01

    This Phase II Nuclear Plant Aging Research study examines the methods of detecting pump degradation that are currently employed in domestic and overseas nuclear facilities. This report evaluates the criteria mandated by required pump testing at U.S. nuclear power plants and compares them to those features characteristic of state-of-the-art diagnostic programs and practices currently implemented by other major industries. Since the working condition of the pump driver is crucial to pump operability, a brief review of new applications of motor diagnostics is provided that highlights recent developments in this technology. The routine collection and analysis of spectral data is superior to all other technologies in its ability to accurately detect numerous types and causes of pump degradation. Existing ASME Code testing criteria do not require the evaluation of pump vibration spectra but instead overall vibration amplitude. The mechanical information discernible from vibration amplitude analysis is limited, and several cases of pump failure were not detected in their early stages by vibration monitoring. Since spectral analysis can provide a wealth of pertinent information concerning the mechanical condition of rotating machinery, its incorporation into ASME testing criteria could merit a relaxation in the monthly-to-quarterly testing schedules that seek to verify and assure pump operability. Pump drivers are not included in the current battery of testing. Operational problems thought to be caused by pump degradation were found to be the result of motor degradation. Recent advances in nonintrusive monitoring techniques have made motor diagnostics a viable technology for assessing motor operability. Motor current/power analysis can detect rotor bar degradation and ascertain ranges of hydraulically unstable operation for a particular pump and motor set. The concept of using motor current or power fluctuations as an indicator of pump hydraulic load stability is presented.

  13. Relational integrativity of prime-target pairs moderates congruity effects in evaluative priming.

    Science.gov (United States)

    Ihmels, Max; Freytag, Peter; Fiedler, Klaus; Alexopoulos, Theodore

    2016-05-01

    In evaluative priming, positive or negative primes facilitate reactions to targets that share the same valence. While this effect is commonly explained as reflecting invariant structures in semantic long-term memory or in the sensorimotor system, the present research highlights the role of integrativity in evaluative priming. Integrativity refers to the ease of integrating two concepts into a new meaningful compound representation. In extended material tests using paired comparisons from two pools of positive and negative words, we show that evaluative congruity is highly correlated with integrativity. Therefore, in most priming studies, congruity and integrativity are strongly confounded. When both aspects are disentangled by manipulating congruity and integrativity orthogonally, three priming experiments show that evaluative-priming effects were confined to integrative prime-target pairs. No facilitation of prime-congruent targets was obtained for non-integrative stimuli. These findings are discussed from a broader perspective on priming conceived as flexible, context-dependent, and serving a generative adaptation function.

  14. Detection of pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Casada, D. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    There are a variety of stressors that can affect the operation of centrifugal pumps. Although these general stressors are active in essentially all centrifugal pumps, the stressor level and the extent of wear and degradation can vary greatly. Parameters that affect the extent of stressor activity are manifold. In order to assure the long-term operational readiness of a pump, it is important to both understand the nature and magnitude of the specific degradation mechanisms and to monitor the performance of the pump. The most commonly applied method of monitoring the condition of not only pumps, but rotating machinery in general, is vibration analysis. Periodic or continuous special vibration analysis is a cornerstone of most pump monitoring programs. In the nuclear industry, non-spectral vibration monitoring of safety-related pumps is performed in accordance with the ASME code. Pump head and flow rate are also monitored, per code requirements. Although vibration analysis has dominated the condition monitoring field for many years, there are other measures that have been historically used to help understand pump condition; advances in historically applied technologies and developing technologies offer improved monitoring capabilities. The capabilities of several technologies (including vibration analysis, dynamic pressure analysis, and motor power analysis) to detect the presence and magnitude of both stressors and resultant degradation are discussed.

  15. Optically pumped atoms

    CERN Document Server

    Happer, William; Walker, Thad

    2010-01-01

    Covering the most important knowledge on optical pumping of atoms, this ready reference is backed by numerous examples of modelling computation for optical pumped systems. The authors show for the first time that modern scientific computing software makes it practical to analyze the full, multilevel system of optically pumped atoms. To make the discussion less abstract, the authors have illustrated key points with sections of MATLAB codes. To make most effective use of contemporary mathematical software, it is especially useful to analyze optical pumping situations in the Liouville spa

  16. Champagne Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  17. Resonance wave pumping: wave mass transport pumping

    Science.gov (United States)

    Carmigniani, Remi; Violeau, Damien; Gharib, Morteza

    2016-11-01

    It has been previously reported that pinching at intrinsic resonance frequencies a valveless pump (or Liebau pump) results in a strong pulsating flow. A free-surface version of the Liebau pump is presented. The experiment consists of a closed tank with a submerged plate separating the water into a free-surface and a recirculation section connected through two openings at each end of the tank. A paddle is placed at an off-centre position at the free-surface and controlled in a heaving motion with different frequencies and amplitudes. Near certain frequencies identified as resonance frequencies through a linear potential theory analysis, the system behaves like a pump. Particle Image Velocimetry (PIV) is performed in the near free surface region and compared with simulations using Volume of Fluid (VOF) method. The mean eulerian mass flux field (ρ) is extracted. It is observed that the flow is located in the vicinity of the surface layer suggesting Stokes Drift (or Wave Mass Transport) is the source of the pumping. A model is developped to extend the linear potential theory to the second order to take into account these observations. The authors would like to acknowledge the Gordon and Betty Moore Foundation for their generous support.

  18. Positive and negative spatial priming in schizophrenia.

    Science.gov (United States)

    Zimmermann, Mark; Stark, Rudolf; Kern, Georg; Laiacker, Manuela; Kirsch, Peter; Vaitl, Dieter

    2006-07-01

    Priming tasks are used for investigating the deficits of selective attention in schizophrenia, which are thought to be related to the psychotic symptoms. Priming was assessed in acutely psychotic unmedicated (n = 22) and medicated (n = 36) schizophrenia patients and in control subjects (n = 42). The subjects had to indicate the location of a target stimulus in two consecutive stimulus displays (prime and probe). Each stimulus appeared together with a distractor on a screen. Negative Priming is characterized by an increase in reaction time, whenever a probe target is presented at a prime distractor location. Positive Priming is characterized by a decrease in reaction time, when the probe target is presented at the prime target location. Schizophrenia patients altogether showed no abnormalities in priming effects, neither in the acute phase of illness (medicated and unmedicated) nor in partial remission (one month later, medicated). In unmedicated patients however Negative Priming was inversely correlated with the severity of positive symptoms. This indicates a priming deficit in a small subgroup of severely ill patients. The data support the notion that automatic (implicit) mechanisms of learning are unimpaired in schizophrenia patients unless symptoms exceed a certain critical level.

  19. Wrath of God: religious primes and punishment.

    Science.gov (United States)

    McKay, Ryan; Efferson, Charles; Whitehouse, Harvey; Fehr, Ernst

    2011-06-22

    Recent evidence indicates that priming participants with religious concepts promotes prosocial sharing behaviour. In the present study, we investigated whether religious priming also promotes the costly punishment of unfair behaviour. A total of 304 participants played a punishment game. Before the punishment stage began, participants were subliminally primed with religion primes, secular punishment primes or control primes. We found that religious primes strongly increased the costly punishment of unfair behaviours for a subset of our participants--those who had previously donated to a religious organization. We discuss two proximate mechanisms potentially underpinning this effect. The first is a 'supernatural watcher' mechanism, whereby religious participants punish unfair behaviours when primed because they sense that not doing so will enrage or disappoint an observing supernatural agent. The second is a 'behavioural priming' mechanism, whereby religious primes activate cultural norms pertaining to fairness and its enforcement and occasion behaviour consistent with those norms. We conclude that our results are consistent with dual inheritance proposals about religion and cooperation, whereby religions harness the byproducts of genetically inherited cognitive mechanisms in ways that enhance the survival prospects of their adherents.

  20. Microbial stress priming: a meta-analysis.

    Science.gov (United States)

    Andrade-Linares, Diana R; Lehmann, Anika; Rillig, Matthias C

    2016-04-01

    Microbes have to cope with complex and dynamic environments, making it likely that anticipatory responses provide fitness benefits. Mild, previous stressors can prepare microbes (stress priming) to further and potentially damaging stressors (triggering). We here quantitatively summarize the findings from over 250 trials of 34 studies including bacteria and fungi, demonstrating that priming to stress has a beneficial impact on microbial survival. In fact, survival of primed microbes was about 10-fold higher compared with that in non-primed microbes. Categorical moderators related to microbial taxonomy and the kind of stress applied as priming or as triggering revealed significant differences of priming effect size among 14 different microbial species, 6 stress categories and stressor combination. We found that priming by osmotic, physiological and temperature stress had the highest positive effect sizes on microbial response. Cross-protection was evident for physiological, temperature and pH stresses. Microbes are better prepared against triggering by oxidative, temperature and osmotic stress. Our finding of an overall positive mean effect of priming regardless of the microbial system and particular stressor provides unprecedentedly strong evidence of the broad ecological significance of microbial stress priming. These results further suggest that stress priming may be an important factor in shaping microbial communities.

  1. The temporal dynamics of visual object priming.

    Science.gov (United States)

    Ko, Philip C; Duda, Bryant; Hussey, Erin P; Mason, Emily J; Ally, Brandon A

    2014-11-01

    Priming reflects an important means of learning that is mediated by implicit memory. Importantly, priming occurs for previously viewed objects (item-specific priming) and their category relatives (category-wide priming). Two distinct neural mechanisms are known to mediate priming, including the sharpening of a neural object representation and the retrieval of stimulus-response mappings. Here, we investigated whether the relationship between these neural mechanisms could help explain why item-specific priming generates faster responses than category-wide priming. Participants studied pictures of everyday objects, and then performed a difficult picture identification task while we recorded event-related potentials (ERP). The identification task gradually revealed random line segments of previously viewed items (Studied), category exemplars of previously viewed items (Exemplar), and items that were not previously viewed (Unstudied). Studied items were identified sooner than Unstudied items, showing evidence of item-specific priming, and importantly Exemplar items were also identified sooner than Unstudied items, showing evidence of category-wide priming. Early activity showed sustained neural suppression of parietal activity for both types of priming. However, these neural suppression effects may have stemmed from distinct processes because while category-wide neural suppression was correlated with priming behavior, item-specific neural suppression was not. Late activity, examined with response-locked ERPs, showed additional processes related to item-specific priming including neural suppression in occipital areas and parietal activity that was correlated with behavior. Together, we conclude that item-specific and category-wide priming are mediated by separate, parallel neural mechanisms in the context of the current paradigm. Temporal differences in behavior are determined by the timecourses of these distinct processes.

  2. Demanding pump power; Krevende pumpekraft

    Energy Technology Data Exchange (ETDEWEB)

    Lie, Oeyvind

    2011-07-01

    The potential for pump power in Norway is huge, but it is difficult to exploit it. Norway has some pumping plants, but these are built for seasonal pumping (pumping up to the magazine in the summer, and production in the winter). Pump power plants for short periods do not exist in Norway. (AG)

  3. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    relative to the rod element so as to allow for a fluid flow in the tube through the first valve member, along the rod element, and through the second valve member. The tube comprises an at least partly flexible tube portion between the valve members such that a repeated deformation of the flexible tube...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  4. Quantitative assessment of haemolysis secondary to modern infusion pumps.

    Science.gov (United States)

    Poder, T G; Boileau, J-C; Lafrenière, R; Thibault, L; Carrier, N; de Grandmont, M-J; Beauregard, P

    2017-04-01

    Although most studies have shown that little haemolysis is induced by infusion pumps, there are some notable exceptions. Only limited data are available on the actual infusion pumps that are most used in hospitals in Quebec and elsewhere, namely, the Infusomat(®) Space (peristaltic), Plum A+™ (piston) and Colleague(®) CXE (shuttle) pumps. Haemolysis and potassium levels were compared before and after the use of the three different infusion pumps. Using 135 units of packed red blood cells (RBCs) aged from 10 to 28 days, 27 measurements were taken for each pump at various flow rates (30, 60, 150, 300 and 450 ml/h) and were compared with measurements taken before using the pumps. The range of flow rates was chosen to cover those of paediatric and adult transfusions. The shuttle- and piston-type pumps resulted in low haemolysis levels. The peristaltic-type pump produced significantly more haemolysis, which worsened at low flow rates, but the absolute value of haemolysis remained within the range recommended by the regulatory agencies in North America and Europe. Approximately two-thirds of the haemolysis produced by the peristaltic-type pump seemed to be secondary to the use of an antisiphon valve (ASV) on the transfusion line recommended by the manufacturer. Potassium levels did not increase with the use of the pumps. Modern infusion pumps widely used in hospitals in Quebec and elsewhere produce non-threatening levels of haemolysis during the transfusion of packed RBCs aged from 10 to 28 days. ASVs appear to induce additional haemolysis, and we do not recommend using them for blood transfusion. © 2017 International Society of Blood Transfusion.

  5. A paradox of syntactic priming: Why response tendencies show priming for passives, and response latencies show priming for actives

    OpenAIRE

    Corley, M.; Segaert, K.; Menenti, L.; Weber, K; Hagoort, P.

    2011-01-01

    Speakers tend to repeat syntactic structures across sentences, a phenomenon called syntactic priming. Although it has been suggested that repeating syntactic structures should result in speeded responses, previous research has focused on effects in response tendencies. We investigated syntactic priming effects simultaneously in response tendencies and response latencies for active and passive transitive sentences in a picture description task. In Experiment 1, there were priming effects in re...

  6. A paradox of syntactic priming: Why response tendencies show priming for passives, and response latencies show priming for actives

    OpenAIRE

    Corley, M.; Segaert, K.; Menenti, L.; Weber, K.; Hagoort, P.

    2011-01-01

    Speakers tend to repeat syntactic structures across sentences, a phenomenon called syntactic priming. Although it has been suggested that repeating syntactic structures should result in speeded responses, previous research has focused on effects in response tendencies. We investigated syntactic priming effects simultaneously in response tendencies and response latencies for active and passive transitive sentences in a picture description task. In Experiment 1, there were priming effects in re...

  7. The direction of masked auditory category priming correlates with participants' prime discrimination ability.

    Science.gov (United States)

    Bermeitinger, Christina; Wentura, Dirk; Koppermann, Christopher; Hauser, Micha; Grass, Benjamin; Frings, Christian

    2012-01-01

    Semantic priming refers to the phenomenon that participants typically respond faster to targets following semantically related primes as compared to semantically unrelated primes. In contrast, Wentura and Frings (2005) found a negatively signed priming effect (i.e., faster responses to semantically unrelated as compared to semantically related targets) when they used (a) a special masking technique for the primes and (b) categorically related prime-target-pairs (e.g., fruit-apple). The negatively signed priming effect was most pronounced for participants with random prime discrimination performance, whereas participants with high prime discrimination performance showed a positive effect. In the present study we analyzed the after-effects of masked category primes in audition. A comparable pattern of results as in the visual modality emerged: The poorer the individual prime discrimination, the more negative is the semantic priming effect. This result is interpreted as evidence for a common mechanism causing the semantic priming effect in vision as well as in audition instead of a perceptual mechanism only working in the visual domain.

  8. First observation of the M1 transition $\\psi^\\prime\\to \\gamma\\eta_c^\\prime$

    CERN Document Server

    Ablikim, M; Ambrose, D J; An, F F; An, Q; An, Z H; Bai, J Z; Ban, Y; Becker, J; Berger, N; Bertani, M; Bian, J M; Boger, E; Bondarenko, O; Boyko, I; Briere, R A; Bytev, V; Cai, X; Calcaterra, A; Cao, G F; Chang, J F; Chelkov, G; Chen, G; Chen, H S; Chen, J C; Chen, M L; Chen, S J; Chen, Y; Chen, Y B; Cheng, H P; Chu, Y P; Cronin-Hennessy, D; Dai, H L; Dai, J P; Dedovich, D; Deng, Z Y; Denig, A; Denysenko, I; Destefanis, M; Ding, W M; Ding, Y; Dong, L Y; Dong, M Y; Du, S X; Fang, J; Fang, S S; Fava, L; Feldbauer, F; Feng, C Q; Ferroli, R B; Fu, C D; Fu, J L; Gao, Y; Geng, C; Goetzen, K; Gong, W X; Gradl, W; Greco, M; Gu, M H; Gu, Y T; Guan, Y H; Guo, A Q; Guo, L B; Guo, Y P; Han, Y L; Hao, X Q; Harris, F A; He, K L; He, M; He, Z Y; Held, T; Heng, Y K; Hou, Z L; Hu, H M; Hu, J F; Hu, T; Huang, B; Huang, G M; Huang, J S; Huang, X T; Huang, Y P; Hussain, T; Ji, C S; Ji, Q; Ji, X B; Ji, X L; Jia, L K; Jiang, L L; Jiang, X S; Jiao, J B; Jiao, Z; Jin, D P; Jin, S; Jing, F F; Kalantar-Nayestanaki, N; Kavatsyuk, M; Kuehn, W; Lai, W; Lange, J S; Leung, J K C; Li, C H; Li, Cheng; Li, Cui; Li, D M; Li, F; Li, G; Li, H B; Li, J C; Li, K; Li, Lei; Li, N B; Li, Q J; Li, S L; Li, W D; Li, W G; Li, X L; Li, X N; Li, X Q; Li, X R; Li, Z B; Liang, H; Liang, Y F; Liang, Y T; Liao, G R; Liao, X T; Liu, B J; Liu, B J; Liu, C L; Liu, C X; Liu, C Y; Liu, F H; Liu, Fang; Liu, Feng; Liu, H; Liu, H B; Liu, H H; Liu, H M; Liu, H W; Liu, J P; Liu, K Y; Liu, Kai; Liu, Kun; Liu, P L; Liu, S B; Liu, X; Liu, X H; Liu, Y; Liu, Y B; Liu, Z A; Liu, Zhiqiang; Liu, Zhiqing; Loehner, H; Lu, G R; Lu, H J; Lu, J G; Lu, Q W; Lu, X R; Lu, Y P; Luo, C L; Luo, M X; Luo, T; Luo, X L; Lv, M; Ma, C L; Ma, F C; Ma, H L; Ma, Q M; Ma, S; Ma, T; Ma, X Y; Ma, Y; Maas, F E; Maggiora, M; Malik, Q A; Mao, H; Mao, Y J; Mao, Z P; Messchendorp, J G; Min, J; Min, T J; Mitchell, R E; Mo, X H; Morales, C Morales; Motzko, C; Muchnoi, N Yu; Nefedov, Y; Nicholson, C; Nikolaev, I B; Ning, Z; Olsen, S L; Ouyang, Q; Pacetti, S; Park, J W; Pelizaeus, M; Peng, H P; Peters, K; Ping, J L; Ping, R G; Poling, R; Prencipe, E; Pun, C S J; Qi, M; Qian, S; Qiao, C F; Qin, X S; Qin, Y; Qin, Z H; Qiu, J F; Rashid, K H; Rong, G; Ruan, X D; Sarantsev, A; Schaefer, B D; Schulze, J; Shao, M; Shen, C P; Shen, X Y; Sheng, H Y; Shepherd, M R; Song, X Y; Spataro, S; Spruck, B; Sun, D H; Sun, G X; Sun, J F; Sun, S S; Sun, X D; Sun, Y J; Sun, Y Z; Sun, Z J; Sun, Z T; Tang, C J; Tang, X; Thorndike, E H; Tian, H L; Toth, D; Ullrich, M; Varner, G S; Wang, B; Wang, B Q; Wang, K; Wang, L L; Wang, L S; Wang, M; Wang, P; Wang, P L; Wang, Q; Wang, Q J; Wang, S G; Wang, X F; Wang, X L; Wang, Y D; Wang, Y F; Wang, Y Q; Wang, Z; Wang, Z G; Wang, Z Y; Wei, D H; Weidenkaff, P; Wen, Q G; Wen, S P; Werner, M; Wiedner, U; Wu, L H; Wu, N; Wu, S X; Wu, W; Wu, Z; Xia, L G; Xiao, Z J; Xie, Y G; Xiu, Q L; Xu, G F; Xu, G M; Xu, H; Xu, Q J; Xu, X P; Xu, Y; Xu, Z R; Xue, F; Xue, Z; Yan, L; Yan, W B; Yan, Y H; Yang, H X; Yang, T; Yang, Y; Yang, Y X; Ye, H; Ye, M; Ye, M H; Yu, B X; Yu, C X; Yu, J S; Yu, L; Yu, S P; Yuan, C Z; Yuan, W L; Yuan, Y; Zafar, A A; Zallo, A; Zeng, Y; Zhang, B X; Zhang, B Y; Zhang, C C; Zhang, D H; Zhang, H H; Zhang, H Y; Zhang, J; Zhang, J G; Zhang, J Q; Zhang, J W; Zhang, J Y; Zhang, J Z; Zhang, L; Zhang, S H; Zhang, T R; Zhang, X J; Zhang, X Y; Zhang, Y; Zhang, Y H; Zhang, Y S; Zhang, Z P; Zhang, Z Y; Zhao, G; Zhao, H S; Zhao, J W; Zhao, K X; Zhao, Lei; Zhao, Ling; Zhao, M G; Zhao, Q; Zhao, S J; Zhao, T C; Zhao, X H; Zhao, Y B; Zhao, Z G; Zhemchugov, A; Zheng, B; Zheng, J P; Zheng, Y H; Zheng, Z P; Zhong, B; Zhong, J; Zhou, L; Zhou, X K; Zhou, X R; Zhu, C; Zhu, K; Zhu, K J; Zhu, S H; Zhu, X L; Zhu, X W; Zhu, Y M; Zhu, Y S; Zhu, Z A; Zhuang, J; Zou, B S; Zou, J H; Zuo, J X

    2012-01-01

    Using a sample of 106 million $\\psi^\\prime$ events collected with the BESIII detector at the BEPCII storage ring, we have made the first measurement of the M1 transition between the radially excited charmonium $S$-wave spin-triplet and the radially excited $S$-wave spin-singlet states: $\\psi^\\prime\\to\\gamma\\eta_c^\\prime$. Analyses of the processes $\\psi^\\prime\\to \\gamma\\eta_c^\\prime$ with $\\eta_c^\\prime\\to \\K_S^0 K\\pi$ and $K^+K^-\\pi^0$ gave an $\\eta_c^\\prime$ signal with a statistical significance of greater than 10 standard deviations under a wide range of assumptions about the signal and background properties. The data are used to obtain measurements of the $\\eta_c^\\prime$ mass ($M(\\eta_c^\\prime)=3637.6\\pm 2.9_\\mathrm{stat}\\pm 1.6_\\mathrm{sys}$ MeV/$c^2$), width ($\\Gamma(\\eta_c^\\prime)=16.9\\pm 6.4_\\mathrm{stat}\\pm 4.8_\\mathrm{sys}$ MeV), and the product branching fraction ($\\BR(\\psi^\\prime\\to \\gamma\\eta_c^\\prime)\\times \\BR(\\eta_c^\\prime\\to K\\bar K\\pi) = (1.30\\pm 0.20_\\mathrm{stat}\\pm 0.30_\\mathrm{sys})\\tim...

  9. Auditory morphological processing: Evidence from phonological priming.

    Science.gov (United States)

    Bacovcin, Hezekiah Akiva; Goodwin Davies, Amy; Wilder, Robert J; Embick, David

    2017-07-01

    Using an auditory lexical decision task, we find evidence of a facilitatory priming effect for morphologically complex targets (e.g., snow-ed) preceded by primes which rhyme with the target's stem (e.g., dough). By using rhyme priming, we are able to probe for morphological processing in a way that avoids confounds arising from semantic relatedness that are inherent to morphological priming (snow/snow-ed). Phonological control conditions (e.g., targets code and grove for prime dough) are used to rule out alternative interpretations of the effect that are based on partial rhyme or phonological embedding of the stem. The findings provide novel evidence for an independent morphological component in lexical processing and demonstrate the utility of rhyme priming in probing morphological representation. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Multiple Phenotypic Changes Define Neutrophil Priming

    Science.gov (United States)

    Miralda, Irina; Uriarte, Silvia M.; McLeish, Kenneth R.

    2017-01-01

    Exposure to pro-inflammatory cytokines, chemokines, mitochondrial contents, and bacterial and viral products induces neutrophils to transition from a basal state into a primed one, which is currently defined as an enhanced response to activating stimuli. Although, typically associated with enhanced generation of reactive oxygen species (ROS) by the NADPH oxidase, primed neutrophils show enhanced responsiveness of exocytosis, NET formation, and chemotaxis. Phenotypic changes associated with priming also include activation of a subset of functions, including adhesion, transcription, metabolism, and rate of apoptosis. This review summarizes the breadth of phenotypic changes associated with priming and reviews current knowledge of the molecular mechanisms behind those changes. We conclude that the current definition of priming is too restrictive. Priming represents a combination of enhanced responsiveness and activated functions that regulate both adaptive and innate immune responses. PMID:28611952

  11. Priming of antiherbivore defensive responses in plants

    Institute of Scientific and Technical Information of China (English)

    Jinwon Kim; Gary W.Felton

    2013-01-01

    Defense priming is defined as increased readiness of defense induction.A growing body of literature indicates that plants (or intact parts of a plant) are primed in anticipation of impending environmental stresses,both biotic and abiotic,and upon the following stimulus,induce defenses more quickly and strongly.For instance,some plants previously exposed to herbivore-inducible plant volatiles (HIPVs) from neighboring plants under herbivore attack show faster or stronger defense activation and enhanced insect resistance when challenged with secondary insect feeding.Research on priming of antiherbivore defense has been limited to the HIPV-mediated mechanism until recently,but significant advances were made in the past three years,including non-HIPV-mediated defense priming,epigenetic modifications as the molecular mechanism of priming,and others.It is timely to consider the advances in research on defense priming in the plantinsect interactions.

  12. A Shocking New Pump

    Science.gov (United States)

    2000-01-01

    Hydro Dynamics, Inc. received a technical helping hand from NASA that made their Hydrosonic Pump (HPump) a reality. Marshall engineers resolved a bearing problem in the rotor of the pump and recommended new bearings, housings and mounting hardware as a solution. The resulting HPump is able to heat liquids with greater energy efficiency using shock waves to generate heat.

  13. Water Treatment Technology - Pumps.

    Science.gov (United States)

    Ross-Harrington, Melinda; Kincaid, G. David

    One of twelve water treatment technology units, this student manual on pumps provides instructional materials for three competencies. (The twelve units are designed for a continuing education training course for public water supply operators.) The competencies focus on the following areas: types of pumps in plant and distribution systems, pump…

  14. Prime focus spectrograph: Subaru's future

    OpenAIRE

    Sugai, Hajime; Dekany, Richard G.; Ellis, Richard S.; Seiffert, Michael D.; Smith, Roger M.

    2012-01-01

    The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru’s wide field of view, which is further extended with the recently completed Wide Fie...

  15. Can religious priming induce truthful preference revelation?

    OpenAIRE

    Stachtiaris, Spiros; Drichoutis, Andreas; Nayga, Rodolfo; Klonaris, Stathis

    2011-01-01

    We examine whether religious priming can induce more truthful preference revelation in valuation research. Using induced value second price Vickrey auctions in both hypothetical and non-hypothetical contexts, our results suggest that religious priming can indeed induce more truthful bidding and eliminate hypothetical bias in hypothetical contexts. In non-hypothetical contexts where there are real economic incentives, religious priming induces similar truthful bidding as the absence of religio...

  16. Review of magnetohydrodynamic pump applications

    National Research Council Canada - National Science Library

    Al-Habahbeh, O.M; Al-Saqqa, M; Safi, M; Abo Khater, T

    2016-01-01

    Magneto-hydrodynamic (MHD) principle is an important interdisciplinary field. One of the most important applications of this effect is pumping of materials that are hard to pump using conventional pumps...

  17. Complex architecture of primes and natural numbers.

    Science.gov (United States)

    García-Pérez, Guillermo; Serrano, M Ángeles; Boguñá, Marián

    2014-08-01

    Natural numbers can be divided in two nonoverlapping infinite sets, primes and composites, with composites factorizing into primes. Despite their apparent simplicity, the elucidation of the architecture of natural numbers with primes as building blocks remains elusive. Here, we propose a new approach to decoding the architecture of natural numbers based on complex networks and stochastic processes theory. We introduce a parameter-free non-Markovian dynamical model that naturally generates random primes and their relation with composite numbers with remarkable accuracy. Our model satisfies the prime number theorem as an emerging property and a refined version of Cramér's conjecture about the statistics of gaps between consecutive primes that seems closer to reality than the original Cramér's version. Regarding composites, the model helps us to derive the prime factors counting function, giving the probability of distinct prime factors for any integer. Probabilistic models like ours can help to get deeper insights about primes and the complex architecture of natural numbers.

  18. A comparison of diesel, biodiesel and solar PV-based water pumping systems in the context of rural Nepal

    DEFF Research Database (Denmark)

    Parajuli, Ranjan; Pokharel, Govind Raj; Østergaard, Poul Alberg

    2014-01-01

    using petro-diesel, jatropha-based biodiesel and solar photovoltaic pumps. The technical system design consists of system sizing of prime mover (engine, solar panel and pumps) and estimation of reservoir capacity, which are based on the annual aggregate water demand modelling. With these investigations...... area, the levelised cost of pumping 1 L of water is higher than that of a solar pump and even higher when compared with diesel, if the seed yield per plant is less than 2 kg and without subsidy on the investment cost of cultivation and processing. With the productivity of 2.5 kg/plant, a biodiesel......-based system is more attractive than that of the diesel-based pump, but still remains more expensive than that of solar pump. From the technical perspective (reliability and easiness in operation) and economic evaluation of the technical alternatives, solar pumping system is found to be the most viable...

  19. Pumping machinery theory and practice

    CERN Document Server

    Badr, Hassan M

    2014-01-01

    Pumping Machinery Theory and Practice comprehensively covers the theoretical foundation and applications of pumping machinery. Key features: Covers characteristics of centrifugal pumps, axial flow pumps and displacement pumpsConsiders pumping machinery performance and operational-type problemsCovers advanced topics in pumping machinery including multiphase flow principles, and two and three-phase flow pumping systemsCovers different methods of flow rate control and relevance to machine efficiency and energy consumptionCovers different methods of flow rate control and relevance to machine effi

  20. PDCA循环对微量泵注射多巴胺预防连续性血液净化过程中低血压的影响%Effect of PDCA cycle in the prevention of hypotension during continuous blood purification by micro-pump injection of dopamine

    Institute of Scientific and Technical Information of China (English)

    顾永梅

    2016-01-01

    目的::探讨PDCA循环在微量泵注射多巴胺预防连续性血液净化过程中低血压的应用效果。方法:选择2015年1~6月接受微量泵注射多巴胺治疗的42例血液净化低血压患者作为对照组,治疗期间应用常规性护理;选择2015年7~12月接受微量泵注射多巴胺治疗的42例血液净化低血压患者作为观察组,治疗期间应用PDCA循环护理模式,对比分析两组患者治疗效果、不良反应、护理满意度及血压变化情况。结果:观察组低血压、微量泵阻塞、多巴胺渗漏、肢体肿胀、内瘘血栓发生率及护理纠纷发生率均低于对照组(P<0.05)。观察组患者净化后1,2,3 d收缩压、舒张压均高于对照组(P<0.05)。观察组在健康教育、医疗环境、心理护理、服务态度及操作性护理方面满意度评分高于对照组(P<0.05)。结论:PDCA循环能有效预防血液透析低血压的发生,降低微量泵临床应用风险事件及意外事件的发生,提高患者治疗满意度。%Objective:To explore the application effect of PDCA cycle in the prevention of hypotension during continuous blood purification by micro-pump injection of dopamine. Methods:Selected 42 cases of patients with hypotension during blood purification dated from January 2015 to June 2015 who received treatment of micro-pump injection of dopamine as control group. During the treatment,they were treated with routine nursing. Selected 42 cases of patients with hypotension during blood purification dated from July 2015 to December 2015 who received treatment of micro-pump injection of dopamine as observa-tion group. During the treatment,they were treated with PDCA cycle nursing. The therapeutic effect, adverse reaction,nursing satisfaction and blood pres-sure were compared between the two groups. Results:The incidence of hypotension,micro-pump obstruction,dopamine leakage,limb swelling,internal fis-tula thrombosis and nursing disputes of the observation

  1. Tight Coupling between Positive and Reversed Priming in the Masked Prime Paradigm

    Science.gov (United States)

    Boy, Frederic; Sumner, Petroc

    2010-01-01

    When associations between certain visual stimuli and particular actions are learned, those stimuli become capable of automatically and unconsciously activating their associated action plans. Such sensorimotor priming is assumed to be fundamental for efficient responses, and can be reliably measured in masked prime studies even when the primes are…

  2. The Effect of Prime Duration in Masked Orthographic Priming Depends on Neighborhood Distribution

    Science.gov (United States)

    Robert, Christelle; Mathey, Stephanie

    2012-01-01

    A lexical decision task was used with a masked priming procedure to investigate whether and to what extent neighborhood distribution influences the effect of prime duration in masked orthographic priming. French word targets had two higher frequency neighbors that were either distributed over two letter positions (e.g., "LOBE/robe-loge")…

  3. Priming effects on the N400 in the affective priming paradigm with facial expressions of emotion.

    Science.gov (United States)

    Aguado, Luis; Dieguez-Risco, Teresa; Méndez-Bértolo, Constantino; Pozo, Miguel A; Hinojosa, José A

    2013-06-01

    We studied the effect of facial expression primes on the evaluation of target words through a variant of the affective priming paradigm. In order to make the affective valence of the faces irrelevant to the task, the participants were assigned a double prime-target task in which they were unpredictably asked either to identify the gender of the face or to evaluate whether the word was pleasant or unpleasant. Behavioral and electrophysiological (event-related potential, or ERP) indices of affective priming were analyzed. Temporal and spatial versions of principal components analyses were used to detect and quantify those ERP components associated with affective priming. Although no significant behavioral priming was observed, electrophysiological indices showed a reverse priming effect, in the sense that the amplitude of the N400 was higher in response to congruent than to incongruent negative words. Moreover, a late positive potential (LPP), peaking around 700 ms, was sensitive to affective valence but not to prime-target congruency. This pattern of results is consistent with previous accounts of ERP effects in the affective priming paradigm that have linked the LPP with evaluative priming and the N400 with semantic priming. Our proposed explanation of the N400 priming effects obtained in the present study is based on two assumptions: a double check of affective stimuli in terms of valence and specific emotion content, and the differential specificities of facial expressions of positive and negative emotions.

  4. Inverse Target- and Cue-Priming Effects of Masked Stimuli

    Science.gov (United States)

    Mattler, Uwe

    2007-01-01

    The processing of a visual target that follows a briefly presented prime stimulus can be facilitated if prime and target stimuli are similar. In contrast to these positive priming effects, inverse priming effects (or negative compatibility effects) have been found when a mask follows prime stimuli before the target stimulus is presented: Responses…

  5. Subchronic use of the St. Jude centrifugal pump as a mechanical assist device in calves.

    Science.gov (United States)

    Curtis, J; Wagner-Mann, C; Mann, F; Demmy, T; Walls, J; Turk, J

    1996-06-01

    The purpose of this experiment was to study the effects of the St. Jude Lifestream centrifugal pump on hemodynamic and hematologic parameters and the incidence of postmortem findings in a subchronic ex vivo left ventricular assist animal model. Five calves were implanted with the pump as a left ventricular assist device (left atrial to thoracic aorta bypass) and studied for 96 h of continuous pumping under identical conditions. Heparin (100 IU/kg) was administered only in the initial saline pump prime. Throughout the protocol, mean arterial and central venous pressures averaged 102.1 +/- 4.6 and 3.4 +/- 2.2 mm Hg, respectively. Pump flow was 47.8 +/- 8.4 ml/kg/min at a mean pump speed of 1,676.3 +/- 106.1 rpm. No clinical abnormalities or mechanical malfunctions attributable to the pump were detected during the 96 h of continuous pumping for each calf. Mean plasma-free hemoglobin after 96 h was 3.9 +/- 3.7 mumol/L (p = 0.337 compared to baseline). At post mortem, renal infarctions were detected in 1 calf. No other pump-associated lesions were detected in any of the other calves. We have concluded that the St. Jude Lifestream centrifugal pump functions reliably during 96 h of continuous left heart bypass in a calf model.

  6. The big squeeze : multi-phase pumping technology aims to increase recovery rates from aging fields

    Energy Technology Data Exchange (ETDEWEB)

    Ross, E.

    2008-04-15

    New technologies developed to assist with offshore oil and gas activities were discussed. The BP King multi-phase pumping project in the Gulf of Mexico is now expecting to enhance production by 20 per cent and extend the life of its field by 5 years through the use of multibooster pumps installed in 2007. The subsea boosting technology has reduced back pressure on the wells and increased oil recovery rates. Multi-phase pumping increased the distance over which the wellstream could be transported. The pump consisted of 4 main components: (1) a motor barrel; (2) a motor cartridge; (3) a pump barrel; and (4) a twin screw pump cartridge. The twin screw product has the ability to pump oil and gas streams with a range of gas void fractions. The pump is self-priming and runs at a relatively low rate. Changes to the pitch and diameter of the screw are used to control the volume of flow and the pressure. The project is also using a long-distance, high voltage distribution system to control multiple pumps at different speeds. The power umbilical system was developed to provide delivery lines for hydraulic fluids, and the umbilical cords also house a fibre-optic communications system to ensure high speed pump response. 3 figs.

  7. One version of direct response priming requires automatization of the relevant associations but not awareness of the prime.

    Science.gov (United States)

    Klapp, Stuart T

    2015-07-01

    Priming is the influence of one event on performance during a second event. One type of priming is known as semantic priming because it biases interpretation of the subsequent stimulus. Another type, direct response priming, biases responding directly without semantic mediation. Research reviewed in this article indicates that two versions of the second type, direct response priming, can be distinguished. One version, explicit priming, requires awareness of the prime. The other version, associative response priming, occurs even if the prime is masked and not phenomenally visible. This version, which is attributed to associations relating specific sensory events to movements of particular muscles, is enabled only if the association has previously been automatized by brief practice in which the to-be-primed response is made to the stimulus that subsequently appears as the prime. Associative response priming can be explained by a simple stimulus-response interpretation; other varieties of priming are more theoretically challenging. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Radial-Electric-Field Piezoelectric Diaphragm Pumps

    Science.gov (United States)

    Bryant, Robert G.; Working, Dennis C.; Mossi, Karla; Castro, Nicholas D.; Mane, Pooma

    2009-01-01

    In a recently invented class of piezoelectric diaphragm pumps, the electrode patterns on the piezoelectric diaphragms are configured so that the electric fields in the diaphragms have symmetrical radial (along-the-surface) components in addition to through-the-thickness components. Previously, it was accepted in the piezoelectric-transducer art that in order to produce the out-of-plane bending displacement of a diaphragm needed for pumping, one must make the electric field asymmetrical through the thickness, typically by means of electrodes placed on only one side of the piezoelectric material. In the present invention, electrodes are placed on both sides and patterned so as to produce substantial radial as well as through-the-thickness components. Moreover, unlike in the prior art, the electric field can be symmetrical through the thickness. Tests have shown in a given diaphragm that an electrode configuration according to this invention produces more displacement than does a conventional one-sided electrode pattern. The invention admits of numerous variations characterized by various degrees of complexity. Figure 1 is a simplified depiction of a basic version. As in other piezoelectric diaphragm pumps of similar basic design, the prime mover is a piezoelectric diaphragm. Application of a suitable voltage to the electrodes on the diaphragm causes it to undergo out-of-plane bending. The bending displacement pushes a fluid out of, or pulls the fluid into, a chamber bounded partly by the diaphragm. Also as in other diaphragm pumps in general, check valves ensure that the fluid flows only in through one port and only out through another port.

  9. Efflux pump-mediated resistance in chemotherapy.

    Science.gov (United States)

    Ughachukwu, Po; Unekwe, Pc

    2012-07-01

    Efflux pump mechanisms perform important physiological functions such as prevention of toxin absorption from the gastrointestinal tract, elimination of bile from the hepatocytes, effective functioning of the blood-brain barrier and placental barrier, and renal excretion of drugs. They exist in all living cells, but those in the bacterial and mammalian cells are more important to the clinician and pharmacologist, as they constitute an important cause of antimicrobial drug resistance, which contributes to treatment failure, high medical bills, and increased mortality / morbidity. This review was aimed at highlighting the role of efflux pump mechanisms in microbial resistance to chemotherapeutic agents. It was also aimed to elucidate their structure and mechanisms of action so as to integrate the efflux pump mechanisms in the design and development of novel antimicrobial agents. Findings from previous studies and research on this subject assessed through Google search, Pubmed, Hinari websites, as well as standard textbooks on chemotherapy, provided the needed information in the process of this review. Efflux pump inhibitors are promising strategies for preventing and reverting efflux-mediated resistance to chemotherapeutic agents. They are usually employed as adjuncts in antimicrobial and cancer chemotherapy. Toxicity, more common with the older-generation inhibitors such as verapamil and reserpine, constitutes the greatest impediment to their clinical applications. No efflux pump inhibitor has been approved for routine clinical use, as a result of doubtful clinical efficacy and unacceptably high incidence of adverse effects, particularly inhibition of the P-450 drug metabolizing enzyme. At present, their applications are mainly restricted to epidemiological studies. Nonetheless, the search for efficacious and tolerable efflux pump inhibitors continues because of the potential benefits. There is a need to consider efflux pump substrate selectivity in the design and

  10. Prime pairs and the zeta function

    NARCIS (Netherlands)

    Korevaar, J.

    2009-01-01

    Are there infinitely many prime pairs with given even difference? Most mathematicians think so. Using a strong arithmetic hypothesis, Goldston, Pintz and Yildirim have recently shown that there are infinitely many pairs of primes differing by at most sixteen. There is extensive numerical support for

  11. Phasic Affective Modulation of Semantic Priming

    Science.gov (United States)

    Topolinski, Sascha; Deutsch, Roland

    2013-01-01

    The present research demonstrates that very brief variations in affect, being around 1 s in length and changing from trial to trial independently from semantic relatedness of primes and targets, modulate the amount of semantic priming. Implementing consonant and dissonant chords (Experiments 1 and 5), naturalistic sounds (Experiment 2), and visual…

  12. 7 CFR 29.2290 - Premature primings.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Premature primings. 29.2290 Section 29.2290 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... 21) § 29.2290 Premature primings. Ground leaves harvested before reaching complete growth and...

  13. Semilocal formal fibers of principal prime ideals

    CERN Document Server

    Chatlos, John; Watson, Nathaniel G; Wu, Sherry X

    2009-01-01

    Let (T,m) be a complete local (Notherian) ring, C a finite set of pairwise incomparable nonmaximal prime ideals of T, and p a nonzero element. We provide necessary and sufficient conditions for T to be the completion of an integral domain A containing the prime ideal pA whose formal fiber is semilocal with maximal ideals the elements of C.

  14. Goal priming as a situated intervention tool

    NARCIS (Netherlands)

    Papies, Esther K.

    2016-01-01

    Research on goal priming has shown that cues in the environment can lead to goal-directed cognition and behaviour without the need for conscious intentions. This has sparked an interest in using goal priming as an intervention tool to strategically influence behaviour in line with an individual's

  15. Syntactic priming in American Sign Language.

    Science.gov (United States)

    Hall, Matthew L; Ferreira, Victor S; Mayberry, Rachel I

    2015-01-01

    Psycholinguistic studies of sign language processing provide valuable opportunities to assess whether language phenomena, which are primarily studied in spoken language, are fundamentally shaped by peripheral biology. For example, we know that when given a choice between two syntactically permissible ways to express the same proposition, speakers tend to choose structures that were recently used, a phenomenon known as syntactic priming. Here, we report two experiments testing syntactic priming of a noun phrase construction in American Sign Language (ASL). Experiment 1 shows that second language (L2) signers with normal hearing exhibit syntactic priming in ASL and that priming is stronger when the head noun is repeated between prime and target (the lexical boost effect). Experiment 2 shows that syntactic priming is equally strong among deaf native L1 signers, deaf late L1 learners, and hearing L2 signers. Experiment 2 also tested for, but did not find evidence of, phonological or semantic boosts to syntactic priming in ASL. These results show that despite the profound differences between spoken and signed languages in terms of how they are produced and perceived, the psychological representation of sentence structure (as assessed by syntactic priming) operates similarly in sign and speech.

  16. Morphological Priming Effects on Children's Spelling

    Science.gov (United States)

    Rosa, Joao Manuel; Nunes, Terezinha

    2008-01-01

    Previous research has suggested that children in the early grades of primary school do not have much awareness of morphemes. In this study, a priming paradigm was used to try to detect early signs of morphological representation of stems through a spelling task presented to Portuguese children (N = 805; age range 6-9 years). Primes shared the stem…

  17. Prime pairs and the zeta function

    NARCIS (Netherlands)

    Korevaar, J.

    2009-01-01

    Are there infinitely many prime pairs with given even difference? Most mathematicians think so. Using a strong arithmetic hypothesis, Goldston, Pintz and Yildirim have recently shown that there are infinitely many pairs of primes differing by at most sixteen. There is extensive numerical support for

  18. Can False Memories Prime Problem Solutions?

    Science.gov (United States)

    Howe, Mark L.; Garner, Sarah R.; Dewhurst, Stephen A.; Ball, Linden J.

    2010-01-01

    Previous research has suggested that false memories can prime performance on related implicit and explicit memory tasks. The present research examined whether false memories can also be used to prime higher order cognitive processes, namely, insight-based problem solving. Participants were asked to solve a number of compound remote associate task…

  19. Negative Priming in Free Recall Reconsidered

    Science.gov (United States)

    Hanczakowski, Maciej; Beaman, C. Philip; Jones, Dylan M.

    2016-01-01

    Negative priming in free recall is the finding of impaired memory performance when previously ignored auditory distracters become targets of encoding and retrieval. This negative priming has been attributed to an aftereffect of deploying inhibitory mechanisms that serve to suppress auditory distraction and minimize interference with learning and…

  20. Visual Priming of Inverted and Rotated Objects

    Science.gov (United States)

    Knowlton, Barbara J.; McAuliffe, Sean P.; Coelho, Chase J.; Hummel, John E.

    2009-01-01

    Object images are identified more efficiently after prior exposure. Here, the authors investigated shape representations supporting object priming. The dependent measure in all experiments was the minimum exposure duration required to correctly identify an object image in a rapid serial visual presentation stream. Priming was defined as the change…

  1. Phasic Affective Modulation of Semantic Priming

    Science.gov (United States)

    Topolinski, Sascha; Deutsch, Roland

    2013-01-01

    The present research demonstrates that very brief variations in affect, being around 1 s in length and changing from trial to trial independently from semantic relatedness of primes and targets, modulate the amount of semantic priming. Implementing consonant and dissonant chords (Experiments 1 and 5), naturalistic sounds (Experiment 2), and visual…

  2. Morphological Priming Survives a Language Switch

    Science.gov (United States)

    Verdonschot, Rinus G.; Middelburg, Renee; Lensink, Saskia E.; Schiller, Niels O.

    2012-01-01

    In a long-lag morphological priming experiment, Dutch (L1)-English (L2) bilinguals were asked to name pictures and read aloud words. A design using non-switch blocks, consisting solely of Dutch stimuli, and switch-blocks, consisting of Dutch primes and targets with intervening English trials, was administered. Target picture naming was facilitated…

  3. The Apollo 11 Prime Crew

    Science.gov (United States)

    1969-01-01

    Portrait of the prime crew of the Apollo 11 lunar landing mission. From left to right they are: Commander, Neil A. Armstrong, Command Module Pilot, Michael Collins, and Lunar Module Pilot, Edwin E. Aldrin Jr. On July 20th 1969 at 4:18 PM, EDT the Lunar Module 'Eagle' landed in a region of the Moon called the Mare Tranquillitatis, also known as the Sea of Tranquillity. After securing his spacecraft, Armstrong radioed back to earth: 'Houston, Tranquility Base here, the Eagle has landed'. At 10:56 p.m. that same evening and witnessed by a worldwide television audience, Neil Armstrong stepped off the 'Eagle's landing pad onto the lunar surface and said: 'That's one small step for a man, one giant leap for mankind.' He became the first human to set foot upon the Moon.

  4. Random reward priming is task-contingent

    DEFF Research Database (Denmark)

    Ásgeirsson, Árni Gunnar; Kristjánsson, Árni

    2014-01-01

    Consistent financial reward of particular features influences the allocation of visual attention in many ways. More surprising are 1-trial reward priming effects on attention where reward schedules are random and reward on one trial influences attentional allocation on the next. Those findings...... for a Gabor patch of odd spatial frequency we found no evidence of reward priming, while we only partially replicate the reward priming in the exact original paradigm tested by Hickey and colleagues. The results cast doubt on the proposal that random reward enhances salience, suggested in the original papers......, and highlight the need for a more nuanced account. In many other paradigms reward effects have been found to progress gradually, becoming stronger as they build up, and we argue that for robust reward priming, reward schedules need to be more consistent than in the original 1-trial reward priming paradigm....

  5. Prime power polynomial maps over finite fields

    CERN Document Server

    Berson, Joost

    2012-01-01

    We consider polynomial maps described by so-called prime power polynomials. These polynomials are defined using a fixed power of a prime number, say q. Considering invertible polynomial maps of this type over a characteristic zero field, we will only obtain (up to permutation of the variables) triangular maps, which are the most basic examples of polynomial automorphisms. However, over the finite field F_q automorphisms of this type have (in general) an entirely different structure. Namely, we will show that the prime power polynomial maps over F_q are in one-to-one correspondence with matrices having coefficients in a univariate polynomial ring over F_q. Furthermore, composition of polynomial maps translates to matrix multiplication, implying that invertible prime power polynomial maps correspond to invertible matrices. This alternate description of the prime power polynomial automorphism subgroup leads to the solution of many famous conjectures for this kind of polynomials and polynomial maps.

  6. Object color affects identification and repetition priming.

    Science.gov (United States)

    Uttl, Bob; Graf, Peter; Santacruz, Pilar

    2006-10-01

    We investigated the influence of color on the identification of both non-studied and studied objects. Participants studied black and white and color photos of common objects and memory was assessed with an identification test. Consistent with our meta-analysis of prior research, we found that objects were easier to identify from color than from black and white photos. We also found substantial priming in all conditions, and study-to-test changes in an object's color reduced the magnitude of priming. Color-specific priming effects were large for color-complex objects, but minimal for color-simple objects. The pattern and magnitude of priming effects was not influenced either by the extent to which an object always appears in the same color (i.e., whether a color is symptomatic of an object) or by the object's origin (natural versus fabricated). We discuss the implications of our findings for theoretical accounts of object perception and repetition priming.

  7. Priming analogical reasoning with false memories.

    Science.gov (United States)

    Howe, Mark L; Garner, Sarah R; Threadgold, Emma; Ball, Linden J

    2015-08-01

    Like true memories, false memories are capable of priming answers to insight-based problems. Recent research has attempted to extend this paradigm to more advanced problem-solving tasks, including those involving verbal analogical reasoning. However, these experiments are constrained inasmuch as problem solutions could be generated via spreading activation mechanisms (much like false memories themselves) rather than using complex reasoning processes. In three experiments we examined false memory priming of complex analogical reasoning tasks in the absence of simple semantic associations. In Experiment 1, we demonstrated the robustness of false memory priming in analogical reasoning when backward associative strength among the problem terms was eliminated. In Experiments 2a and 2b, we extended these findings by demonstrating priming on newly created homonym analogies that can only be solved by inhibiting semantic associations within the analogy. Overall, the findings of the present experiments provide evidence that the efficacy of false memory priming extends to complex analogical reasoning problems.

  8. Random reward priming is task-contingent

    DEFF Research Database (Denmark)

    Ásgeirsson, Árni Gunnar; Kristjánsson, Árni

    2014-01-01

    Consistent financial reward of particular features influences the allocation of visual attention in many ways. More surprising are 1-trial reward priming effects on attention where reward schedules are random and reward on one trial influences attentional allocation on the next. Those findings...... for a Gabor patch of odd spatial frequency we found no evidence of reward priming, while we only partially replicate the reward priming in the exact original paradigm tested by Hickey and colleagues. The results cast doubt on the proposal that random reward enhances salience, suggested in the original papers......, and highlight the need for a more nuanced account. In many other paradigms reward effects have been found to progress gradually, becoming stronger as they build up, and we argue that for robust reward priming, reward schedules need to be more consistent than in the original 1-trial reward priming paradigm....

  9. Nuclear-pumped lasers

    CERN Document Server

    Prelas, Mark

    2016-01-01

    This book focuses on Nuclear-Pumped Laser (NPL) technology and provides the reader with a fundamental understanding of NPLs, a review of research in the field, and exploration of large scale NPL system design and applications. Early chapters look at the fundamental properties of lasers, nuclear-pumping and nuclear reactions that may be used as drivers for nuclear-pumped lasers. The book goes on to explore the efficient transport of energy from the ionizing radiation to the laser medium and then the operational characteristics of existing nuclear-pumped lasers. Models based on Mathematica, explanations and a tutorial all assist the reader’s understanding of this technology. Later chapters consider the integration of the various systems involved in NPLs and the ways in which they can be used, including beyond the military agenda. As readers will discover, there are significant humanitarian applications for high energy/power lasers, such as deflecting asteroids, space propulsion, power transmission and mining....

  10. Absorption heat pump system

    Science.gov (United States)

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  11. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  12. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  13. Underground pumped hydroelectric storage

    Science.gov (United States)

    Allen, R. D.; Doherty, T. J.; Kannberg, L. D.

    1984-07-01

    Underground pumped hydroelectric energy storage was conceived as a modification of surface pumped storage to eliminate dependence upon fortuitous topography, provide higher hydraulic heads, and reduce environmental concerns. A UPHS plant offers substantial savings in investment cost over coal-fired cycling plants and savings in system production costs over gas turbines. Potential location near load centers lowers transmission costs and line losses. Environmental impact is less than that for a coal-fired cycling plant. The inherent benefits include those of all pumped storage (i.e., rapid load response, emergency capacity, improvement in efficiency as pumps improve, and capacity for voltage regulation). A UPHS plant would be powered by either a coal-fired or nuclear baseload plant. The economic capacity of a UPHS plant would be in the range of 1000 to 3000 MW. This storage level is compatible with the load-velocity requirements of a greater metropolitan area with population of 1 million or more.

  14. Chiral brownian heat pump.

    Science.gov (United States)

    van den Broek, M; Van den Broeck, C

    2008-04-04

    We present the exact analysis of a chiral Brownian motor and heat pump. Optimization of the construction predicts, for a nanoscale device, frequencies of the order of kHz and cooling rates of the order of femtojoule per second.

  15. Chiral Brownian heat pump

    OpenAIRE

    Van Den Broek, Martijn; Van Den Broeck, Christian

    2007-01-01

    We present the exact analysis of a chiral Brownian motor and heat pump. Optimization of the construction predicts, for a nanoscale device, frequencies of the order of kHz and cooling rates of the order of femtojoule per second.

  16. Regenerative Hydride Heat Pump

    Science.gov (United States)

    Jones, Jack A.

    1992-01-01

    Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

  17. Shifting evaluation windows: predictable forward primes with long SOAs eliminate the impact of backward primes.

    Science.gov (United States)

    Fockenberg, Daniel A; Koole, Sander L; Lakens, Daniël; Semin, Gün R

    2013-01-01

    Recent work suggests that people evaluate target stimuli within short and flexible time periods called evaluation windows. Stimuli that briefly precede a target (forward primes) or briefly succeed a target (backward primes) are often included in the target's evaluation. In this article, the authors propose that predictable forward primes act as "go" signals that prepare target processing, such that earlier forward primes pull the evaluation windows forward in time. Earlier forward primes may thus reduce the impact of backward primes. This shifting evaluation windows hypothesis was tested in two experiments using an evaluative decision task with predictable (vs. unpredictable) forward and backward primes. As expected, a longer time interval between a predictable forward prime and a target eliminated backward priming. In contrast, the time interval between an unpredictable forward primes and a target had no effects on backward priming. These findings suggest that predictable features of dynamic stimuli can shape target extraction by determining which information is included (or excluded) in rapid evaluation processes.

  18. Effect of seed priming on agronomic performance and cost ...

    African Journals Online (AJOL)

    Effect of seed priming on agronomic performance and cost effectiveness of rainfed, dry-seeded nerica rice. ... Open Access DOWNLOAD FULL TEXT ... vitamin (Ascorbate) priming, hardening, osmohardening, and a non-primed control.

  19. Movement-Based Priming: Clinical Applications and Neural Mechanisms.

    Science.gov (United States)

    Stoykov, Mary Ellen; Corcos, Daniel Montie; Madhavan, Sangeetha

    2017-01-01

    Priming can be described as behavior change generated by preceding stimuli. Although various types of priming have been long studied in the field of psychology, priming that targets motor cortex is a relatively new topic of research in the fields of motor control and rehabilitation. In reference to a rehabilitation intervention, priming is categorized as a restorative approach. There are a myriad of possible priming approaches including noninvasive brain stimulation, motor imagery, and sensory-based priming, to name a few. The authors report on movement-based priming which, compared to other priming types, is less frequently examined and under reported. Movement-based priming includes, but is not limited to, bilateral motor priming, unilateral priming, and aerobic exercise. Clinical and neural mechanistic aspects of movement-based priming techniques are explored.

  20. Remotely Adjustable Hydraulic Pump

    Science.gov (United States)

    Kouns, H. H.; Gardner, L. D.

    1987-01-01

    Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.

  1. Velocity selective optical pumping

    OpenAIRE

    Aminoff, C. G.; Pinard, M.

    1982-01-01

    We consider optical pumping with a quasi monochromatic tunable light beam, in the low intensity limit where a rate equation regime is obtained The velocity selective optical pumping (V.S.O.P.) introduces a correlation between atomic velocity and internal variables in the ground (or metastable) state. The aim of this article is to evaluate these atomic observables (orientation, alignment, population) as a function of velocity, using a phenomenological description of the relaxation effect of co...

  2. Lunar Base Heat Pump

    Science.gov (United States)

    Walker, D.; Fischbach, D.; Tetreault, R.

    1996-01-01

    The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

  3. Downwell pump reliability: Geothermal experience update: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P.F.

    1988-01-01

    Geothermal resources with temperatures between 250/sup 0/ and 360/sup 0/F (121/sup 0/C and 182/sup 0/C) are prime candidates for binary-cycle power generation, and constitute about 80% of the power-capable resources in the United States. The successful exploitation of these resources requires reliable high-capacity downwell brine production pumps, but earlier experience showed that high-capacity, high-temperature geothermal production pumps had many problems which resulted in a mean time-to-failure (MTTF) of less than 1000 h. However, steady progress has been made since 1981, and a large body of experience has been acquired by three geothermal binary plants. This survey of high-temperature geothermal downwell pump users and manufacturers updates a prior survey (AP-3572) completed in early 1983. This survey traces the development of lineshaft pump technology from the late 1970s to the present (mid-1987), detailing the advances in design, materials selection, and operating practices. Case histories of 72 lineshaft pumps installed at three geothermal binary plants since late 1981 are documented, including some detailed cause of failure reports. In the recent past, pump lives in excess of 7000 h have become common, but a high continuing rate of premature failures resulted in a mean time-to-failure (MTTF) of about 5000 h. Based on recent advances which appear likely to eliminate most premature failures, the estimated near-term MTTF will be on the order of 8000 h. The survey found almost no development of high-temperature geothermal electric submersible pumps (ESP's) or close-coupled downwell hydraulic turbopumps, and concluded that considerable development and demonstration will be needed before these technologies are able to compete with existing high-temperature geothermal lineshaft pump technology. 36 refs., 10 figs., 25 tabs.

  4. Exponential sums over primes in short intervals

    Institute of Scientific and Technical Information of China (English)

    LIU; Jianya

    2006-01-01

    [1]Vinogradov,I.M.,Estimation of certain trigonometric sums with prime variables,Izv.Acad.Nauk.SSSR,1939,3:371-398.[2]Zhan,T.,On the representation of large odd integer as a sum of three almost equal primes,Acta Math.Sin.,1991,7:259-272.[3]Ren,X.M.,On exponential sums over primes and application in the Waring-Goldbach problem,Sci.China,Ser.A-Math.,2005,48(6):785-797.[4]Liu,J.Y.,Wooley,T.D.,Yu,G.,The quadratic Waring-Goldbach problem,J.Number Theory,2004,107:298-321.[5]Hua,L.K.,Some results in the additive prime number theory,Quart.J.Math.(Oxford),1938,9:68-80.[6]Liu,J.Y.,Zhan,T.,On sums of five almost equal prime squares,Acta Arith.,1996,77:369-383.[7]Bauer,C.,A note on sums of five almost equal prime squares,Arch.Math,1997,69:20-30.[8]Liu,J.Y.,Zhan,T.,Sums of five almost equal prime squares,Science in China,Ser.A,1998,41:710-722.[9]Liu,J.Y.,Zhan,T.,Hua's theorem on prime squares in short intervals,Acta Math.Sin.,2000,16:1-22.[10]Bauer,C.,Sums of five almost equal prime squares,Acta Math.Sin.,2005,21(4):833-840.[11]Lü,G.S.,Hua's Theorem with five almost equal prime variables,Chin.Ann.Math.,Ser.B,2005,26(2):291-304.[12]Vinogradov,I.M.,Elements of Number Theory,Dover Publications,1954.[13]Titchmarsh,E.C.,The Theory of the Riemann Zeta-function,2nd ed.,Oxford:Oxford University Press,1986.

  5. Pumping a playground swing.

    Science.gov (United States)

    Post, Auke A; de Groot, Gert; Daffertshofer, Andreas; Beek, Peter J

    2007-04-01

    In mechanical studies of pumping a playground swing, two methods of energy insertion have been identified: parametric pumping and driven oscillation. While parametric pumping involves the systematic raising and lowering of the swinger's center of mass (CM) along the swing's radial axis (rope), driven oscillation may be conceived as rotation of the CM around a pivot point at a fixed distance to the point of suspension. We examined the relative contributions of those two methods of energy insertion by inviting 18 participants to pump a swing from standstill and by measuring and analyzing the swing-swinger system (defined by eight markers) in the sagittal plane. Overall, driven oscillation was found to play a major role and parametric pumping a subordinate role, although the relative contribution of driven oscillation decreased as swinging amplitude increased, whereas that of parametric pumping increased slightly. Principal component analysis revealed that the coordination pattern of the swing-swinger system was largely determined (up to 95%) by the swing's motion, while correlation analysis revealed that (within the remaining 5% of variance) trunk and leg rotations were strongly coupled.

  6. In vitro evaluation of the TandemHeart pediatric centrifugal pump.

    Science.gov (United States)

    Svitek, Robert G; Smith, Douglas E; Magovern, James A

    2007-01-01

    The pediatric TandemHeart pump is being developed for short-term circulatory support of patients varying in size from 2 to 40 kg. The pump withdraws blood from the left atrium via cannula inserted percutaneously, either through the right internal jugular vein or transhepatically, and pumps the blood back into the arterial system via the carotid or femoral artery. High resolution stereolithography (SLA) was used to create an upper housing and impeller design, which were assembled into a functional pump prototype. Pressure-flow characteristics of the pump were determined in a blood analogue solution and compared with the pressure-flow requirements of the intended cannulation. At 5,500 rpm, the pump was able to generate 0.4 L/min of flow with a pressure rise of 325 mm Hg and 2.0 L/min with a pressure rise of 250 mm Hg. The hydraulic performance of the pump will enable at least 50% of cardiac output when the arterial cannula is placed in the carotid artery. The hemolysis of the TandemHeart pediatric pump at 5,500 rpm was compared with the BP-50 pediatric centrifugal pump in vitro using bovine blood flowing at 0.4 L/min against 250 mm Hg. The TandemHeart pump produced a similar increase in plasma free hemoglobin levels during the duration of the 6 hour test.

  7. Pressure and gap length dependence of gap breakdown voltage and discharge current of discharge-pumped KrF excimer laser. Hoden reiki KrF laser no zetsuen hakai den prime atsu to reiki denryu no atsuryoku, gap cho izon sei

    Energy Technology Data Exchange (ETDEWEB)

    Yukimura, K.; Kawakami, H. (Doshisha Univ., Tokyo (Japan)); Hitomi, K. (Kyoto Polytechnic College, Kyoto (Japan))

    1991-04-20

    On the gap destruction characteristics of UV-preionized discharge-pumped KrF excimer laser (charge transfer type) and the electric characteristics of the excited discharge, studies were made by changing the pressure (1.5-3 atm) and the discharge gap length (14-21 mm) of the discharge medium. (1) Gap breakdown voltage and the maximum current of the excited discharge give a similarity by a product of pressure and the gap length at the charge volatge. (2) Insulation breakdown of the gap occurs at the wave front of the applied voltage and the breakdown time gets delayed by the decreasing voltage applied. By setting the ionization index at constant value 20, the gap breakdown voltage is estimated at the error within 10%. (3) The relation between the maximum current, pressure and the gap length product changes the characteristics by the charge voltage of the primary condenser. With the result combined with the standardization of voltage/current of the excited discharge, the electric characteristics at the specific pressure and gap length can be readily known. 10 refs., 10 figs.

  8. E 1 transitions from the. Upsilon. prime prime state and the fine structure of the. chi. sub b prime states

    Energy Technology Data Exchange (ETDEWEB)

    Narain, M.; Lovelock, D.M.J.; Heintz, U.; Lee-Franzini, J.; Schamberger, R.D.; Willins, J.; Yanagisawa, C. (State University of New York at Stony Brook, Stony Brook, New York 11794 (USA)); Franzini, P.; Tuts, P.M.; Kanekal, S.; Wu, Q.W. (Columbia University, New York, New York 10027 (USA))

    1991-06-17

    Using the CUSB-II detector at the Cornell Electron Storage Ring, we have made precision measurements of the electric dipole transition rates from {Upsilon}{prime}{prime} to {chi}{sub {ital b}}{sup {prime}}, which are in excellent agreement with theory. The fine-structure splitting is found to be {ital M}({chi}{sub {ital b}2}{sup {prime}}){minus}{ital M}({chi}{sub {ital b}1}{sup {prime}})=13.5{plus minus}0.4{plus minus}0.5 MeV and {ital M}({chi}{sub {ital b}1}{sup {prime}}){minus}{ital M}({chi}{sub {ital b}0}{sup {prime}})=23.3{plus minus}0.7{plus minus}0.7 MeV, leading to a ratio {ital R}=0.584{plus minus}0.024{plus minus}0.02. The fine structure measures the relative contributions of the spin-orbit interaction {ital a}=9.5{plus minus}0.2{plus minus}0.1 MeV and tensor interaction {ital b}=2.3{plus minus}0.1{plus minus}0.1 MeV. We also find that the long-range confining potential transforms as a Lorentz scalar.

  9. Comparison of Modified Chandler, Roller Pump, and Ball Valve Circulation Models for In Vitro Testing in High Blood Flow Conditions: Application in Thrombogenicity Testing of Different Materials for Vascular Applications

    Directory of Open Access Journals (Sweden)

    Wim van Oeveren

    2012-01-01

    We concluded that the Hemobile minimally affects blood and could be adjusted to high blood flows, simulating arterial shear stress. The Hemobile was used to measure hemocompatibility of graft material and showed Dyneema Purity UHMWPE fiber in many ways more hemocompatible than ePTFE and PET.

  10. Phonological and Orthographic Overlap Effects in Fast and Masked Priming

    Science.gov (United States)

    Frisson, Steven; Bélanger, Nathalie N.; Rayner, Keith

    2014-01-01

    We investigated how orthographic and phonological information is activated during reading, using a fast priming task, and during single word recognition, using masked priming. Specifically, different types of overlap between prime and target were contrasted: high orthographic and high phonological overlap (track-crack), high orthographic and low phonological overlap (bear-gear), or low orthographic and high phonological overlap (fruit-chute). In addition, we examined whether (orthographic) beginning overlap (swoop-swoon) yielded the same priming pattern as end (rhyme) overlap (track-crack). Prime durations were 32 and 50ms in the fast priming version, and 50ms in the masked priming version, and mode of presentation (prime and target in lower case) was identical. The fast priming experiment showed facilitatory priming effects when both orthography and phonology overlapped, with no apparent differences between beginning and end overlap pairs. Facilitation was also found when prime and target only overlapped orthographically. In contrast, the masked priming experiment showed inhibition for both types of end overlap pairs (with and without phonological overlap), and no difference for begin overlap items. When prime and target only shared principally phonological information, facilitation was only found with a long prime duration in the fast priming experiment, while no differences were found in the masked priming version. These contrasting results suggest that fast priming and masked priming do not necessarily tap into the same type of processing. PMID:24365065

  11. Phonological and orthographic overlap effects in fast and masked priming.

    Science.gov (United States)

    Frisson, Steven; Bélanger, Nathalie N; Rayner, Keith

    2014-01-01

    We investigated how orthographic and phonological information is activated during reading, using a fast priming task, and during single-word recognition, using masked priming. Specifically, different types of overlap between prime and target were contrasted: high orthographic and high phonological overlap (track-crack), high orthographic and low phonological overlap (bear-gear), or low orthographic and high phonological overlap (fruit-chute). In addition, we examined whether (orthographic) beginning overlap (swoop-swoon) yielded the same priming pattern as end (rhyme) overlap (track-crack). Prime durations were 32 and 50 ms in the fast priming version and 50 ms in the masked priming version, and mode of presentation (prime and target in lower case) was identical. The fast priming experiment showed facilitatory priming effects when both orthography and phonology overlapped, with no apparent differences between beginning and end overlap pairs. Facilitation was also found when prime and target only overlapped orthographically. In contrast, the masked priming experiment showed inhibition for both types of end overlap pairs (with and without phonological overlap) and no difference for begin overlap items. When prime and target only shared principally phonological information, facilitation was only found with a long prime duration in the fast priming experiment, while no differences were found in the masked priming version. These contrasting results suggest that fast priming and masked priming do not necessarily tap into the same type of processing.

  12. Thermally Actuated Hydraulic Pumps

    Science.gov (United States)

    Jones, Jack; Ross, Ronald; Chao, Yi

    2008-01-01

    Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research

  13. Custom Unit Pump Design and Testing for the EVA PLSS

    Science.gov (United States)

    Schuller, Michael; Kurwitz, Cable; Goldman, Jeff; Morris, Kim; Trevino, Luis

    2009-01-01

    This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F

  14. Blood sugar test - blood

    Science.gov (United States)

    ... blood glucose level ( hypoglycemia ) may be due to: Hypopituitarism (a pituitary gland disorder) Underactive thyroid gland or ... tonic-clonic seizure Glucagon blood test Glucagonoma Hyperthyroidism Hypopituitarism Hypothyroidism Insulinoma Low blood sugar Multiple endocrine neoplasia ( ...

  15. The helical flow pump with a hydrodynamic levitation impeller.

    Science.gov (United States)

    Abe, Yusuke; Ishii, Kohei; Isoyama, Takashi; Saito, Itsuro; Inoue, Yusuke; Ono, Toshiya; Nakagawa, Hidemoto; Nakano, Emiko; Fukazawa, Kyoko; Ishihara, Kazuhiko; Fukunaga, Kazuyoshi; Ono, Minoru; Imachi, Kou

    2012-12-01

    The helical flow pump (HFP) is a novel rotary blood pump invented for developing a total artificial heart (TAH). The HFP with a hydrodynamic levitation impeller, which consists of a multi-vane impeller involving rotor magnets, stator coils at the core position, and double helical-volute pump housing, was developed. Between the stator and impeller, a hydrodynamic bearing is formed. Since the helical volutes are formed at both sides of the impeller, blood flows with a helical flow pattern inside the pump. The developed HFP showed maximum output of 19 l/min against 100 mmHg of pressure head and 11 % maximum efficiency. The profile of the H-Q (pressure head vs. flow) curve was similar to that of the undulation pump. Hydrodynamic levitation of the impeller was possible with higher than 1,000 rpm rotation speed. The normalized index of the hemolysis ratio of the HFP to centrifugal pump (BPX-80) was from 2.61 to 8.07 depending on the design of the bearing. The HFP was implanted in two goats with a left ventricular bypass method. After surgery, hemolysis occurred in both goats. The hemolysis ceased on postoperative days 14 and 9, respectively. In the first experiment, no thrombus was found in the pump after 203 days of pumping. In the second experiment, a white thrombus was found in the pump after 23 days of pumping. While further research and development are necessary, we are expecting to develop an excellent TAH with the HFP.

  16. Re-naming D Double Prime

    Science.gov (United States)

    Chao, Benjamin F.

    1999-01-01

    "Knowledge about the dynamics of the D double prime region is a key to unlock some fundamental mysteries of the Earth heat engine which governs a wide range of global geophysical processes from tectonics to geodynamo." This benign sentence makes complete sense to many geophysicists. But for many others, it makes sense all except the odd nomenclature "D double prime". One knows about the crust, upper and lower mantle, outer and inner core, but where is the D double prime region? What meaning does it try to convey? Where is D prime region, or D, or A, B, C regions for that matter, and are there higher-order primes? How does such an odd name come about anyway? D double prime, or more "simply" D", is a generic designation given to the thin shell, about 200 km thick, of the lowermost mantle just above the core-mantle boundary inside the Earth. Incidentally, whether D" is "simpler" than "D double prime" depends on whether you are pronouncing it or writing/typing it; and D" can be confusing to readers in distinguishing quotation marks (such as in the above sentences) and second derivatives, and to word processors in spelling check and indexing.

  17. Electronic Unit Pump Test Bench Development and Pump Properties Research

    Institute of Scientific and Technical Information of China (English)

    LIU Bo-lan; HUANG Ying; ZHANG Fu-jun; ZHAO Chang-lu

    2006-01-01

    A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test bot h mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is d one. Experimental results show that the injection quantity is linear with the de livery angle. The quantity change rate is 15% when fuel temperature increases 30℃. The delivery quantity per cycle increases 30mg at 28V drive voltage. T he average delivery difference for two same type pumps is 5%. Test results show that the bench can be used for unit pump verification.

  18. Centrifugal pump and roller pump in adult cardiac surgery: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Saczkowski, Richard; Maklin, Michelle; Mesana, Thierry; Boodhwani, Munir; Ruel, Marc

    2012-08-01

    Centrifugal pump (CP) and roller pump (RP) designs are the dominant main arterial pumps used in cardiopulmonary bypass (CPB). Trials reporting clinical outcome measures comparing CP and RP are controversial. Therefore, a meta-analysis was undertaken to evaluate clinical variables from randomized controlled trials (RCTs). Keyword searches were performed on Medline (1966-2011), EmBase (1980-2011), and CINAHL (1981-2011) for studies comparing RP and CP as the main arterial pump in adult CPB. Pooled fixed-effects estimates for dichotomous and continuous data were calculated as an odds ratio and weighted-mean difference, respectively. The P value was utilized to assess statistical significance (P pump-related malfunction or mishap. The meta-analysis of RCTs comparing CP and RP in adult cardiac surgery suggests no significant difference for hematological variables, postoperative blood loss, transfusions, neurological outcomes, or mortality.

  19. Hydroxyethyl starch versus Ringer solution in cardiopulmonary bypass prime solutions (a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ozyazıcıoglu Ahmet

    2008-07-01

    Full Text Available Abstract Background In our study we compared the Ringer solution, which is the standard prime solution of our department, with the HES (Hydroxyethyl starch 130-0.4 solution, which can be a potential alternative prime solution with an indispensable material for the cardio-pulmonary bypass applications. Methods 140 patients undergoing to CABG (Coronary Artery Bypass Graft surgery were electively enrolled to the study. 1500 ml Ringer solution + 200 ml mannitol + 60 ml sodium bicarbonate + 150 U/kg heparin was used as a prime solution to start cardiopulmonary by-pass in 70 patients which was defined as group 1. On the other hand, 1500 ml HES 130 - 0.4 + 200 ml mannitol + 60 ml sodium bicarbonate + 150 U/kg heparin was used as a prime solution in 70 patients in group 2. Results INR (International Normalized Ratio, urea levels and blood platelet counts were significantly different between the groups. INR level was higher in group 1, while blood urea and creatinine levels and platelet count were higher in group 2 at the end of the 12th and 24nd hours postoperatively (p = 0.001. In this study, it was shown that the usage of HES 130-0.4 as a prime solution did not have negative effect on postoperative INR level, platelet count, the need for transfusion and the amount of drainage, despite the negative opinions that similar solutions caused coagulation disorders. Another interesting result of the study was that blood platelet count at 24th hour was statistically significantly higher in group 2 (p = 0.001. Conclusion HES 130-0.4 solution is an alternative colloidal solution which can be used as the prime solution or as a mixture with the crystalloids in cardio-pulmonary bypass applications.

  20. 模糊Prime元%Fuzzy Prime Elements

    Institute of Scientific and Technical Information of China (English)

    饶三平

    2012-01-01

    基于完备剩余格,本文在模糊完备格中,引入模糊Prime元概念.给出了模糊Prime元的等价刻画,证明了所有的模糊Prime元构成的模糊集是模糊完全分配格.%Based on complete residuated lattices, the concept of fuzzy Prime elements in fuzzy complete lattices is given, then the equivalent characterization of fuzzy Prime elements is obtained. We also prove that the fuzzy subsets of fuzzy Prime elements is a fuzzy completely distributice lattice.

  1. An introduction to E-Prime

    Directory of Open Access Journals (Sweden)

    Dominic Charbonneau

    2009-09-01

    Full Text Available When running an experiment, precision is essential to ensure results are as exact as possible. Thus, computers, which offer endless accuracy, have become an inevitable tool to design experiments. To avoid programming from scratch for each new situation, a program, E-Prime, has been created to ease the conception of experiments. E-Prime, developed by PSTNet, offers a user-friendly interface that makes typical experiments easy to create. This paper shows how to effortlessly create an experiment with E-Prime, followed by a simple example.

  2. A Paradox of Syntactic Priming: Why Response Tendencies Show Priming for Passives, and Response Latencies Show Priming for Actives

    NARCIS (Netherlands)

    Segaert, K.R.; Menenti, L.M.E.; Weber, K.M.; Hagoort, P.

    2011-01-01

    Speakers tend to repeat syntactic structures across sentences, a phenomenon called syntactic priming. Although it has been suggested that repeating syntactic structures should result in speeded responses, previous research has focused on effects in response tendencies. We investigated syntactic

  3. Magnetohydrodynamic pump with a system for promoting flow of fluid in one direction

    Science.gov (United States)

    Lemoff, Asuncion V.; Lee, Abraham P.

    2010-07-13

    A magnetohydrodynamic pump for pumping a fluid. The pump includes a microfluidic channel for channeling the fluid, a MHD electrode/magnet system operatively connected to the microfluidic channel, and a system for promoting flow of the fluid in one direction in the microfluidic channel. The pump has uses in the medical and biotechnology industries for blood-cell-separation equipment, biochemical assays, chemical synthesis, genetic analysis, drug screening, an array of antigen-antibody reactions, combinatorial chemistry, drug testing, medical and biological diagnostics, and combinatorial chemistry. The pump also has uses in electrochromatography, surface micromachining, laser ablation, inkjet printers, and mechanical micromilling.

  4. A Passively-Suspended Tesla Pump Left Ventricular Assist Device

    Science.gov (United States)

    Izraelev, Valentin; Weiss, William J.; Fritz, Bryan; Newswanger, Raymond K.; Paterson, Eric G.; Snyder, Alan; Medvitz, Richard B.; Cysyk, Joshua; Pae, Walter E.; Hicks, Dennis; Lukic, Branka; Rosenberg, Gerson

    2009-01-01

    The design and initial test results of a new passively suspended Tesla type LAVD blood pump are described. CFD analysis was used in the design of the pump. Overall size of the prototype device is 50 mm in diameter and 75 mm in length. The pump rotor has a density lower than that of blood and when spinning inside the stator in blood it creates a buoyant centering force that suspends the rotor in the radial direction. The axial magnetic force between the rotor and stator restrain the rotor in the axial direction. The pump is capable of pumping up to 10 liters/min at a 70 mmHg head rise at 8000 RPM. The pump has demonstrated a normalized index of hemolysis level below .02 mg/dL for flows between 2 and 9.7 L/min. An inlet pressure sensor has also been incorporated into the inlet cannula wall and will be used for control purposes. One initial in vivo study showed an encouraging result. Further CFD modeling refinements are planned as well as endurance testing of the device. PMID:19770799

  5. A Review of the Security of Insulin Pump Infusion Systems

    Science.gov (United States)

    Paul, Nathanael; Kohno, Tadayoshi; Klonoff, David C

    2011-01-01

    Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues. PMID:22226278

  6. A Review of the Security of Insulin Pump Infusion Systems

    Energy Technology Data Exchange (ETDEWEB)

    Klonoff, David C. [Mills-Peninsula Health Services; Paul, Nathanael R [ORNL; Kohno, Tadayoshi [University of Washington, Seattle

    2011-01-01

    Insulin therapy has enabled diabetic patients to maintain blood glucose control to lead healthier lives. Today, rather than manually injecting insulin using syringes, a patient can use a device, such as an insulin pump, to programmatically deliver insulin. This allows for more granular insulin delivery while attaining blood glucose control. The insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this paper we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components including the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but we also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues both for now and in the future.

  7. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  8. Hemolysis research of implantable axial flow pump for two -step heart transplantation in children

    Directory of Open Access Journals (Sweden)

    O. Yu. Dmitrieva

    2017-01-01

    Full Text Available Introduction. One of the main indicators characterizing mechanical circulatory support devices (artificial valve, implantable pumps, etc. is trauma of blood cells. Therefore, while developing new pumps, one of the key studies in vitro is to evaluate blood hemolysis. For an objective hemolysis analysis of pump it is required to create a standardized methodology of hemolysis studies. The object of the study in this paper is implantable axial pump DON for two-step heart transplantation in children.The aim of study is to develop a standardized methodology of hemolysis studies of blood pumps and to conduct research of pediatric axial pump DON.Materials and methods. To conduct hemolysis research we created a mock circulatory system consisting of a reservoir placed in water bath maintaining a constant working fluid (blood temperature, hydrodynamic resistance, connecting tubes, ports for blood sampling and pressure and flow measurement systems, and research pump. Test method is to estimate levels of free hemoglobin pHb obtained by blood samples during pump working in operating mode (for pediatric pump: blood flow 2.5 l/min, pressure difference 80 mmHg. Using the data obtained the standardized indices of hemolysis NIH and MIH are calculated based on pHb values, hematocrit, total hemoglobin, blood flow and working pump time.Results. We developed and realized a standardized methodology of hemolysis research by which we evaluated hemolysis of pediatric axial pump. The results of hemolysis tests allowed us to optimize the design of DON. Obtained values of hemolysis of the latest version of pediatric pump DON-3 have shown that they do conform to the requirements of minimum blood injury and it allows us to proceed to the next step of pediatric pump research – animal experiments.Conclusion. Developed methods and evaluation tools of hemolysis allow us to provide objective information on one of the most important indicators of developing

  9. Prime Focus Spectrograph - Subaru's future -

    CERN Document Server

    Sugai, Hajime; Takato, Naruhisa; Tamura, Naoyuki; Shimono, Atsushi; Ohyama, Youichi; Ueda, Akitoshi; Ling, Hung-Hsu; de Arruda, Marcio Vital; Barkhouser, Robert H; Bennett, Charles L; Bickerton, Steve; Braun, David F; Bruno, Robin J; Carr, Michael A; Oliveira, João Batista de Carvalho; Chang, Yin-Chang; Chen, Hsin-Yo; Dekany, Richard G; Dominici, Tania Pereira; Ellis, Richard S; Fisher, Charles D; Gunn, James E; Heckman, Timothy M; Ho, Paul T P; Hu, Yen-Shan; Jaquet, Marc; Karr, Jennifer; Kimura, Masahiko; Fèvre, Olivier Le; Mignant, David Le; Loomis, Craig; Lupton, Robert H; Madec, Fabrice; Marrara, Lucas Souza; Martin, Laurent; Murayama, Hitoshi; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D; Vilaça, Rodrigo de Paiva; Macanhan, Vanessa Bawden de Paula; Prieto, Eric; Santos, Jesulino Bispo dos; Seiffert, Michael D; Smee, Stephen A; Smith, Roger M; Sodré, Laerte; Spergel, David N; Surace, Christian; Vives, Sebastien; Wang, Shiang-Yu; Yan, Chi-Hung

    2012-01-01

    The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry l...

  10. Modeling self-priming circuits for dielectric elastomer generators towards optimum voltage boost

    Science.gov (United States)

    Zanini, Plinio; Rossiter, Jonathan; Homer, Martin

    2016-04-01

    One of the main challenges for the practical implementation of dielectric elastomer generators (DEGs) is supplying high voltages. To address this issue, systems using self-priming circuits (SPCs) — which exploit the DEG voltage swing to increase its supplied voltage — have been used with success. A self-priming circuit consists of a charge pump implemented in parallel with the DEG circuit. At each energy harvesting cycle, the DEG receives a low voltage input and, through an almost constant charge cycle, generates a high voltage output. SPCs receive the high voltage output at the end of the energy harvesting cycle and supply it back as input for the following cycle, using the DEG as a voltage multiplier element. Although rules for designing self-priming circuits for dielectric elastomer generators exist, they have been obtained from intuitive observation of simulation results and lack a solid theoretical foundation. Here we report the development of a mathematical model to predict voltage boost using self-priming circuits. The voltage on the DEG attached to the SPC is described as a function of its initial conditions, circuit parameters/layout, and the DEG capacitance. Our mathematical model has been validated on an existing DEG implementation from the literature, and successfully predicts the voltage boost for each cycle. Furthermore, it allows us to understand the conditions for the boost to exist, and obtain the design rules that maximize the voltage boost.

  11. Pakistan prime minister pledges science boost

    CERN Multimedia

    1999-01-01

    Pakistan's prime minister announced plans for a 1 billion rupee (23 million US dollars) investment in science and technology. About half is expected to be spent on research and infrasture, the rest on science education (6 paragraphs).

  12. Riemann equation for prime number diffusion.

    Science.gov (United States)

    Chen, Wen; Liang, Yingjie

    2015-05-01

    This study makes the first attempt to propose the Riemann diffusion equation to describe in a manner of partial differential equation and interpret in physics of diffusion the classical Riemann method for prime number distribution. The analytical solution of this equation is the well-known Riemann representation. The diffusion coefficient is dependent on natural number, a kind of position-dependent diffusivity diffusion. We find that the diffusion coefficient of the Riemann diffusion equation is nearly a straight line having a slope 0.99734 in the double-logarithmic axis. Consequently, an approximate solution of the Riemann diffusion equation is obtained, which agrees well with the Riemann representation in predicting the prime number distribution. Moreover, we interpret the scale-free property of prime number distribution via a power law function with 1.0169 the scale-free exponent in respect to logarithmic transform of the natural number, and then the fractal characteristic of prime number distribution is disclosed.

  13. Syntactic Variance and Priming Effects in Translation

    DEFF Research Database (Denmark)

    Bangalore, Srinivas; Behrens, Bergljot; Carl, Michael

    2016-01-01

    The present work investigates the relationship between syntactic variation and priming in translation. It is based on the claim that languages share a common cognitive network of neural activity. When the source and target languages are solicited in a translation context, this shared network can...... on the syntactic level. We tested these hypotheses with translation data from the TPR database, more specifically for three language pairs (English-German, English-Danish, and English-Spanish). Our results show that response times are shorter when syntactic structures are shared. The model explains this through...... lead to facilitation effects, so-called priming effects. We suggest that priming is a default setting in translation, a special case of language use where source and target languages are constantly co-activated. Such priming effects are not restricted to lexical elements, but do also occur...

  14. SATDA teams up with American Prime Group

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>With over 37 years of experience in the real estate industry, American Prime, a family owned and operated company, headquartered in Miami, Florida, is an industry leader in the developing, marketing, selling, and financing of real

  15. Diverging Influences of Money Priming on Choice.

    Science.gov (United States)

    Kim, Hee Jin

    2017-01-01

    Prior research on money priming has suggested two seemingly contradicting findings. On the one hand, money has been shown to highlight the importance of cost saving, leading to the choice of a low-quality/low-price option. On the other hand, individuals primed with money as a symbol of social status, and capabilities may focus on social value of money, e.g., higher spending symbolizes higher status and prefer an option with high quality/high price. Current research proposes and demonstrates that whether money priming will lead different choices depends on the nature of the consumption context. Specifically, when the product is to be consumed privately, money priming will highlight the importance of cost, thus increasing the preference for lower price at a lower quality. However, when the product is to be consumed publicly, reversed pattern of consumer preference will be found.

  16. Reconciling Mechanistic Hypotheses About Rhizosphere Priming

    Science.gov (United States)

    Cheng, W.

    2016-12-01

    Rhizosphere priming on soil organic matter decomposition has emerged as a key mechanism regulating biogeochemnical cycling of carbon, nitrogen and other elements from local to global scales. The level of the rhizosphere priming effect on decomposition rates can be comparable to the levels of controls from soil temperature and moisture conditions. However, our understanding on mechanisms responsible for rhizosphere priming remains rudimentary and controversial. The following individual hypotheses have been postulated in the published literature: (1) microbial activation, (2) microbial community succession, (3) aggregate turnover, (4) nitrogen mining, (5) nutrient competition, (6) preferential substrate utilization, and (7) drying-rewetting. Meshing these hypotheses with existing empirical evidence tends to support a general conclusion: each of these 7 hypotheses represents an aspect of the overall rhizosphere priming complex while the relative contribution by each individual aspect varies depending on the actual plant-soil conditions across time and space.

  17. Suggestibility and negative priming: two replication studies.

    Science.gov (United States)

    David, Daniel; Brown, Richard J

    2002-07-01

    Research suggests that inhibiting the effect of irrelevant stimuli on subsequent thought and action (cognitive inhibition) may be an important component of suggestibility. Two small correlation studies were conducted to address the relationship between different aspects of suggestibility and individual differences in cognitive inhibition, operationalized as the degree of negative priming generated by to-be-ignored stimuli in a semantic categorization task. The first study found significant positive correlations between negative priming, hypnotic suggestibility, and creative imagination; a significant negative correlation was obtained between negative priming and interrogative suggestibility, demonstrating the discriminant validity of the study results. The second study replicated the correlation between negative priming and hypnotic suggestibility, using a different suggestibility measurement procedure that assessed subjective experience and hypnotic involuntariness as well as objective responses to suggestions. These studies support the notion that the ability to engage in cognitive inhibition may be an important component of hypnotic responsivity and maybe of other forms of suggestibility.

  18. Positions priming in briefly presented search arrays

    DEFF Research Database (Denmark)

    Asgeirsson, Arni Gunnar; Kristjánsson, Árni; Kyllingsbæk, Søren;

    2011-01-01

    Repetition priming in visual search has been a topic of extensive research since Maljkovic & Nakayama [1994, Memory & Cognition, 22, 657-672] presented the first detailed studies of such effects. Their results showed large reductions in reaction times when target color was repeated on consecutive...... pop-out search trials. Such repetition effects have since been generalized to a multitude of target attributes. Priming has primarily been investigated using self-terminating visual search paradigms, comparing differences in response times. Response accuracy has predominantly served as a control...... variable. Here we present results from experiments where position priming is demonstrated in paradigms involving temporally limited exposures to singleton targets. Position priming of response accuracy was observed in an eye-movement-controlled spatial judgment task and in partial report tasks where...

  19. Degree of handedness and priming: further evidence for a distinction between production and identification priming mechanisms.

    Science.gov (United States)

    LaVoie, Donna J; Olbinski, Brianna; Palmer, Shayna

    2015-01-01

    The distinction between implicit and explicit forms of memory retrieval is long-standing, and important to the extent it reveals how different neural architecture supports different aspects of memory function. Similarly, distinctions have been made between kinds of repetition priming, a form of implicit memory retrieval. This study focuses on the production-identification (ID) priming distinction, which delineates priming tasks involving verification of stimulus features as compared to priming tasks that require use of a cue to guide response retrieval. Studies investigating this dissociation in dementia or similar patient populations indicate that these forms of priming may differ in their neural bases. The current study looks at degree of handedness as a way of investigating inferred neural architecture supporting these two forms of priming. A growing body of research indicates that degree of handedness (consistent, or CH, versus inconsistent, or ICH) is associated with greater interhemispheric interaction and functional access to right hemisphere processing in ICH, with superior performance seen in ICH on memory tasks reliant on this processing. Arguments about the theoretical mechanisms underlying ID and production forms of perceptual priming tasks suggest that performance on these tasks will differ as a function of degree of handedness. We tested this question in a group of CH and ICH young adults, who were asked to study lists of words prior to performing a production priming task (word stem completion, WSC), a perceptual word ID task, and a word stem cued recall task. While both handedness groups exhibited reliable priming across tasks, WSC priming was greater in ICH than CH participants, with ID priming not differing between groups. This dissociation supports the argument that production and ID forms of priming have different underlying neural bases.

  20. Pulsed differential pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, G.N.; Bagautdinov, F.A.; Rybalov, S.V.

    1985-06-01

    A pulsed differential pumping system is described for extracting an electron beam from a shaping region at a pressure of 10/sup -5/ torr into a volume with a pressure of 10-100 torr. A fast valve is used with appropriate geometrical parameters to reduce the length of the outlet channel considerable while increasing its diameter. Test results are given. The pumping system has two sections which communicate one with the other and with the volume at the elevated pressure which is produced by gasdynamic nozzles.

  1. Heat pump planning handbook

    CERN Document Server

    Bonin, Jürgen

    2015-01-01

    The Heat Pump Planning Handbook contains practical information and guidance on the design, planning and selection of heat pump systems, allowing engineers, designers, architects and construction specialists to compare a number of different systems and options. Including detailed descriptions of components and their functions and reflecting the current state of technology this guide contains sample tasks and solutions as well as new model calculations and planning evaluations. Also economic factors and alternative energy sources are covered, which are essential at a time of rising heat costs. T

  2. Sorption product heat pump

    Energy Technology Data Exchange (ETDEWEB)

    Antonini, G.; Francois, O.; Gendarme, J.P.; Guilleminot, J.J.; Meunier, F.

    1988-07-15

    A continuous operating, and thus with enhanced performance, heat pump is presented. In this heat pump, the heat transfer between the hot source and the output system or network is realized through a solid adsorbent-refrigerant couple having endothermal desorption properties and exothermal adsorption or absorption properties. The sorption products are carried in a closed cycle movement between the two parts of the reactor. Each side of the reactor is assuming always the same function and the thermal inertia have to be overcome only when starting the reactor.

  3. Regenerative adsorbent heat pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    1991-01-01

    A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.

  4. Geothermal Heat Pump Performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  5. Geothermal heat pump performance

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya L.; Lienau, Paul J.

    1995-01-01

    Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

  6. Molecular heat pump.

    Science.gov (United States)

    Segal, Dvira; Nitzan, Abraham

    2006-02-01

    We propose a molecular device that pumps heat against a thermal gradient. The system consists of a molecular element connecting two thermal reservoirs that are characterized by different spectral properties. The pumping action is achieved by applying an external force that periodically modulates molecular levels. This modulation affects periodic oscillations of the internal temperature of the molecule and the strength of its coupling to each reservoir resulting in a net heat flow in the desired direction. The heat flow is examined in the slow and fast modulation limits and for different modulation wave forms, thus making it possible to optimize the device performance.

  7. A Hemodynamic Predict of an Intra-Aorta Pump Application in Vitro Using Numerical Analysis

    Science.gov (United States)

    Gao, Bin; Chen, Ningning; Chang, Yu

    The Intra-Aorta Pump is a novel LVAD assisting the native heart without percutaneous drive-lines. The Intra-Aorta Pump is emplaced between the radix aortae and the aortic arch to draw-off the blood from the left ventricle to the aorta. To predict the change of pressure drop and blood flow along with the change of pump speed, a nonlinear model has been made based on the structure and speed of the Intra-Aorta Pump. To do this, a nonlinear electric circuit for the Intra-Aorta Pump has been developed. The model includes two speed dependent current sources and flow dependent resistant to simulate the relationship between the pressure drop of the Intra-Aorta Pump and the flow through the pump along with the change of pump speed. The pressure drop and blood flow is derived by solving differential equations with variable coefficients. The parameters of the model are determined by experiment, and the results of the experiment show that these parameters change along with the change of the pump speed distinctness. The accuracy of the model is tested experimentally on a test loop. The comparison of the prediction data derived from the model with the experimental data shows that the error is lest than 15%. The experimental results showed that the model can predict the change of pressure drop and blood flow accurately.

  8. Periodicity In The Intervals Between Primes

    Science.gov (United States)

    2015-07-02

    simple proportionality in Eq.(32), such that the basic form of Dc over the range (0,Γ] is repeated in progressively smaller scale over subsequent...striations are an aggregate visual effect that could be produced only from finely-grained periodicity in the δ- dependence of Dp. Figure (6) is a...a randomized analogue of the first 104 primes. indicates a certain ‘Russian dolls’-style self-similarity in the periodicity of the prime intervals

  9. Retro-priming, priming, and double testing: psi and replication in a test-retest design.

    Science.gov (United States)

    Rabeyron, Thomas

    2014-01-01

    Numerous experiments have been conducted in recent years on anomalous retroactive influences on cognition and affect (Bem, 2010), yet more data are needed to understand these processes precisely. For this purpose, we carried out an initial retro-priming study in which the response times of 162 participants were measured (Rabeyron and Watt, 2010). In the current paper, we present the results of a second study in which we selected those participants who demonstrated the strongest retro-priming effect during the first study, in order to see if we could replicate this effect and therefore select high scoring participants. An additional objective was to try to find correlations between psychological characteristics (anomalous experiences, mental health, mental boundaries, trauma, negative life events) and retro-priming results for the high scoring participants. The retro-priming effect was also compared with performance on a classical priming task. Twenty-eight participants returned to the laboratory for this new study. The results, for the whole group, on the retro-priming task, were negative and non-significant (es = -0.25, ns) and the results were significant on the priming task (es = 0.63, p priming results for all the sub-groups (students, male, female). Ten participants were found to have positive results on the two retro-priming studies, but no specific psychological variables were found for these participants compared to the others. Several hypotheses are considered in explaining these results, and the author provide some final thoughts concerning psi and replicability.

  10. Non-cognate translation priming in masked priming lexical decision experiments: A meta-analysis.

    Science.gov (United States)

    Wen, Yun; van Heuven, Walter J B

    2016-09-09

    The masked translation priming paradigm has been widely used in the last 25 years to investigate word processing in bilinguals. Motivated by studies reporting mixed findings, in particular for second language (L2) to first language (L1) translation priming, we conducted, for the first time in the literature, a meta-analysis of 64 masked priming lexical decision experiments across 24 studies to assess the effect sizes of L1-L2 and L2-L1 non-cognate translation priming effects in bilinguals. Our meta-analysis also investigated the influence of potential moderators of translation priming effects. The results provided clear evidence of significant translation priming effects for both directions, with L1-L2 translation priming significantly larger than L2-L1 translation priming (i.e., effect size of 0.86 vs. 0.31). The analyses also revealed that L1-L2 translation effect sizes were moderated by the interval between prime and target (ISI), whereas L2-L1 translation effect sizes were modulated by the number of items per cell. Theoretical and methodological implications of this meta-analysis are discussed and recommendations for future studies are provided.

  11. Comparative study of different control techniques for the regulation of blood glucose level in diabetic patients.

    Science.gov (United States)

    Ibbini, Mohammed S

    2009-01-01

    Blood glucose regulation is of a great concern for insulin-dependant patients with excessive glucose in blood (hyperglycaemia), or low glucose profile (hypoglycaemia) due to excess insulin delivery. Both conditions can cause dangerous complications for diabetic patients, and hence glucose regulation in blood is of prime importance. Insulin pumps are used to deliver insulin in small quantities, allowing the glucose level to remain as close as possible to that of non-diabetics (near 100 mg dl(-1)). Different control techniques are used to maintain the glucose level and most of them depend on an exact mathematical or empirical model of insulin-glucose interaction. Recently, we have proposed different controllers that are based on fuzzy logic and so do not use mathematical modelling, which in general is nonlinear, complex and suffers from uncertainties. PI fuzzy controllers are physically related to classical PI and PID controllers, which are extremely popular. The parameter settings of classical and fuzzy logic controllers are based on deep common physical background. In this manuscript, a comparative study is proposed to evaluate the use of fuzzy logic controllers over other conventional controllers such as PI and PID controllers to maintain the blood glucose level within a normoglycaemic average especially when a diabetic patient is subjected to different conditions.

  12. BLOOD DOPING AND RISKS

    Directory of Open Access Journals (Sweden)

    Goran Vasić

    2015-05-01

    Full Text Available Doping is the way in which athletes misuse of chemicals and other types of medical interventions (eg, blood replacement, try to get ahead in the results of other athletes or their performance at the expense of their own health. The aim of this work is the analysis of blood doping and the display of negative consequences that this way of increasing capabilities brings. Method: The methodological work is done descriptively. Results: Even in 1972 at the Stockholm Institute for gymnastics and sport, first Dr. Bjorn Ekblom started having blood doping. Taken from the blood, athletes through centifuge separating red blood cells from blood plasma, which is after a month of storage in the fridge, every athlete back into the bloodstream. Tests aerobic capacity thereafter showed that the concerned athletes can run longer on average for 25% of the treadmill than before. Discussion: Blood doping carries with it serious risks, excessive amount of red cells “thickens the blood,” increased hematocrit, which reduces the heart’s ability to pump blood to the periphery. All this makes it difficult for blood to flow through blood vessels, and there is a great danger that comes to a halt in the circulation, which can cause cardiac arrest, stroke, pulmonary edema, and other complications that can be fatal.

  13. Semantic Priming for Coordinate Distant Concepts in Alzheimer's Disease Patients

    Science.gov (United States)

    Perri, R.; Zannino, G. D.; Caltagirone, C.; Carlesimo, G. A.

    2011-01-01

    Semantic priming paradigms have been used to investigate semantic knowledge in patients with Alzheimer's disease (AD). While priming effects produced by prime-target pairs with associative relatedness reflect processes at both lexical and semantic levels, priming effects produced by words that are semantically related but not associated should…

  14. Processing Speaker Variability in Repetition and Semantic/Associative Priming

    Science.gov (United States)

    Lee, Chao-Yang; Zhang, Yu

    2015-01-01

    The effect of speaker variability on accessing the form and meaning of spoken words was evaluated in two short-term priming experiments. In the repetition priming experiment, participants listened to repeated or unrelated prime-target pairs, in which the prime and target were produced by the same speaker or different speakers. The results showed…

  15. Processing Speaker Variability in Repetition and Semantic/Associative Priming

    Science.gov (United States)

    Lee, Chao-Yang; Zhang, Yu

    2015-01-01

    The effect of speaker variability on accessing the form and meaning of spoken words was evaluated in two short-term priming experiments. In the repetition priming experiment, participants listened to repeated or unrelated prime-target pairs, in which the prime and target were produced by the same speaker or different speakers. The results showed…

  16. Pure Mediated Priming: A Retrospective Semantic Matching Model

    Science.gov (United States)

    Jones, Lara L.

    2010-01-01

    Mediated priming refers to the activation of a target (e.g., "stripes") by a prime (e.g., "lion") that is related indirectly via a connecting mediator (e.g., tiger). In previous mediated priming studies (e.g., McNamara & Altarriba, 1988), the mediator was associatively related to the prime. In contrast, pure mediated…

  17. Semantic Priming for Coordinate Distant Concepts in Alzheimer's Disease Patients

    Science.gov (United States)

    Perri, R.; Zannino, G. D.; Caltagirone, C.; Carlesimo, G. A.

    2011-01-01

    Semantic priming paradigms have been used to investigate semantic knowledge in patients with Alzheimer's disease (AD). While priming effects produced by prime-target pairs with associative relatedness reflect processes at both lexical and semantic levels, priming effects produced by words that are semantically related but not associated should…

  18. Hyperthermia enhances CTL cross-priming.

    Science.gov (United States)

    Shi, Hongzhen; Cao, Tinghua; Connolly, John E; Monnet, Laurence; Bennett, Lynda; Chapel, Sylvie; Bagnis, Claude; Mannoni, Patrice; Davoust, Jean; Palucka, A Karolina; Banchereau, Jacques

    2006-02-15

    Dendritic cells (DCs) loaded with killed allogeneic melanoma cells can cross-prime naive CD8(+) T cells to differentiate into melanoma-specific CTLs in 3-wk cultures. In this study we show that DCs loaded with killed melanoma cells that were heated to 42 degrees C before killing are more efficient in cross-priming of naive CD8(+) T cells than DCs loaded with unheated killed melanoma cells. The enhanced cross-priming was demonstrated by several parameters: 1) induction of naive CD8(+) T cell differentiation in 2-wk cultures, 2) enhanced killing of melanoma peptide-pulsed T2 cells, 3) enhanced killing of HLA-A*0201(+) melanoma cells in a standard 4-h chromium release assay, and 4) enhanced capacity to prevent tumor growth in vitro in a tumor regression assay. Two mechanisms might explain the hyperthermia-induced enhanced cross-priming. First, heat-treated melanoma cells expressed increased levels of 70-kDa heat shock protein (HSP70), and enhanced cross-priming could be reproduced by overexpression of HSP70 in melanoma cells transduced with HSP70 encoding lentiviral vector. Second, hyperthermia resulted in the increased transcription of several tumor Ag-associated Ags, including MAGE-B3, -B4, -A8, and -A10. Thus, heat treatment of tumor cells permits enhanced cross-priming, possibly via up-regulation of both HSPs and tumor Ag expression.

  19. Components of competitor priming in task switching.

    Science.gov (United States)

    Teskey, Morgan L; Masson, Michael E J

    2017-07-17

    Executing an action in response to a stimulus is thought to result in the creation of an event code that integrates stimulus and action features (Allport, 1987; Hommel in Visual Cognition 5: 183-216, 1998). When switching between tasks, competitor priming occurs if a distractor stimulus cues the retrieval of a previously established event code in which that distractor is bound to a competing task, creating a source of interference with the current task whereby the observer is encouraged to apply the competing task to the distractor. We propose a second aspect of competitor priming: the misapplication of the retrieved competing task to the target stimulus. We report two task-switching experiments in which tasks applied to picture-word compound stimuli were manipulated to create conditions in which this second aspect of competitor priming could be revealed and distinguished from other sources of task- and stimulus-based priming. A substantial increase in competitor priming was observed when subjects switched between tasks that required very different processing operations and the competing task was highly relevant to the target stimulus. These results are consistent with our claim that competitor priming can result from applying the competing task either to the distractor that cued it or to the target stimulus.

  20. 携带式微量注射泵在血液病中治疗铁过载的护理%Nursing of Portable Syringe Pump Iron Overload in the Treatment of Blood Diseases

    Institute of Scientific and Technical Information of China (English)

    陈为

    2014-01-01

    Objective: using portable micro pump subcutaneous deferoxamine to nursing iron overload of iron treatment, in order to improve the clinical treatment ef ect. Methods:I Division in 2011 January--2013 year in August a total of 31 cases of patients with clinical diagnosis of iron overload, the portable micro pump subcutaneous deferoxamine to iron therapy. Results: Patients with iron overload use portable micro injection pump to iron treatment ef icacy. Conclusion: to increase the safety coef icient and the ef ective concentration of the medication of the patients, improve the therapeutic ef ect, is beneficial to the recovery of patients. Simple operation, easy to use, reduces the burden of nurses, improve the quality of medical care, clinical curative ef ect, is a kind of new technique worthy of popularization and application.%目的:采用携带式微量泵皮下注射去铁胺去铁治疗铁过载的护理,以提高临床治疗效果。方法选择我科于2011年1月~2013年8月共有31例血液病患者符合铁过载的临床诊断,采用携带式微量泵皮下注射去铁胺去铁治疗。结果铁过载患者使用携带式微量注射泵去铁治疗效果肯定。结论增加患者用药安全系数和有效浓度,提高治疗效果,有利于患者早日康复。操作简单,使用方便,减轻了护士负担,提高了医疗护理质量,临床疗效确切,是值得推广应用的一种新技术。