Sample records for pulsed spectrometer epr

  1. Integration of a versatile bridge concept in a 34 GHz pulsed/CW EPR spectrometer

    Science.gov (United States)

    Band, Alan; Donohue, Matthew P.; Epel, Boris; Madhu, Shraeya; Szalai, Veronika A.

    2018-03-01

    We present a 34 GHz continuous wave (CW)/pulsed electron paramagnetic resonance (EPR) spectrometer capable of pulse-shaping that is based on a versatile microwave bridge design. The bridge radio frequency (RF)-in/RF-out design (500 MHz to 1 GHz input/output passband, 500 MHz instantaneous input/output bandwidth) creates a flexible platform with which to compare a variety of excitation and detection methods utilizing commercially available equipment external to the bridge. We use three sources of RF input to implement typical functions associated with CW and pulse EPR spectroscopic measurements. The bridge output is processed via high speed digitizer and an in-phase/quadrature (I/Q) demodulator for pulsed work or sent to a wideband, high dynamic range log detector for CW. Combining this bridge with additional commercial hardware and new acquisition and control electronics, we have designed and constructed an adaptable EPR spectrometer that builds upon previous work in the literature and is functionally comparable to other available systems.

  2. Integration of a versatile bridge concept in a 34 GHz pulsed/CW EPR spectrometer.

    Science.gov (United States)

    Band, Alan; Donohue, Matthew P; Epel, Boris; Madhu, Shraeya; Szalai, Veronika A

    2018-03-01

    We present a 34 GHz continuous wave (CW)/pulsed electron paramagnetic resonance (EPR) spectrometer capable of pulse-shaping that is based on a versatile microwave bridge design. The bridge radio frequency (RF)-in/RF-out design (500 MHz to 1 GHz input/output passband, 500 MHz instantaneous input/output bandwidth) creates a flexible platform with which to compare a variety of excitation and detection methods utilizing commercially available equipment external to the bridge. We use three sources of RF input to implement typical functions associated with CW and pulse EPR spectroscopic measurements. The bridge output is processed via high speed digitizer and an in-phase/quadrature (I/Q) demodulator for pulsed work or sent to a wideband, high dynamic range log detector for CW. Combining this bridge with additional commercial hardware and new acquisition and control electronics, we have designed and constructed an adaptable EPR spectrometer that builds upon previous work in the literature and is functionally comparable to other available systems. Published by Elsevier Inc.

  3. Modern pulsed spectrometer EPR for longitudinal relaxation time (T1) investigation - computer programs for measurement and data analysis

    International Nuclear Information System (INIS)

    Ilnicki, J.; Koziol, J.; Galinski, W.; Oles, T.; Kostrzewa, J.; Froncisz, W.

    1994-01-01

    The computerized control and data processing systems for new spectrometer designed for nuclear magnetic resonance studies of biological samples are presented. Both programs were written for INTEL 386 processor and they works under the Windows 3.0 environment

  4. Perspectives of shaped pulses for EPR spectroscopy

    Science.gov (United States)

    Spindler, Philipp E.; Schöps, Philipp; Kallies, Wolfgang; Glaser, Steffen J.; Prisner, Thomas F.

    2017-07-01

    This article describes current uses of shaped pulses, generated by an arbitrary waveform generator, in the field of EPR spectroscopy. We show applications of sech/tanh and WURST pulses to dipolar spectroscopy, including new pulse schemes and procedures, and discuss the more general concept of optimum-control-based pulses for applications in EPR spectroscopy. The article also describes a procedure to correct for experimental imperfections, mostly introduced by the microwave resonator, and discusses further potential applications and limitations of such pulses.

  5. Use of the Frank sequence in pulsed EPR

    DEFF Research Database (Denmark)

    Tseitlin, Mark; Quine, Richard W.; Eaton, Sandra S.

    2011-01-01

    The Frank polyphase sequence has been applied to pulsed EPR of triarylmethyl radicals at 256MHz (9.1mT magnetic field), using 256 phase pulses. In EPR, as in NMR, use of a Frank sequence of phase steps permits pulsed FID signal acquisition with very low power microwave/RF pulses (ca. 1.5m......W in the application reported here) relative to standard pulsed EPR. A 0.2mM aqueous solution of a triarylmethyl radical was studied using a 16mm diameter cross-loop resonator to isolate the EPR signal detection system from the incident pulses. Keyword: Correlation spectroscopy,Multi-pulse EPR,Low power pulses,NMR,EPR...

  6. Superhigh-frequency circuit for the EPR spectrometer with rectifier screening

    International Nuclear Information System (INIS)

    Zhizhchenko, G.A.; Tsvirko, L.V.

    1983-01-01

    The hamodyne SHF circuit of a 3-cm EPR spectrometer with a reflecting resonator is described. The optimum operating mode of SHF-rectifier at a constant phase difference is automatically assured in the circuit. The circuit employs a reflecting p-i-n- attenuator and a SHF-rectifier sereen which simplify the spectrometer tuming. The circuit is used in a miniature EPR radiospectrometer Minsk EPR-6-type

  7. Pulsed EPR for studying silver clusters

    International Nuclear Information System (INIS)

    Michalik, J.; Wasowicz, T.; Sadlo, J.; Reijerse, E.J.; Kevan, L.

    1996-01-01

    The cationic silver clusters of different nuclearity have been produced by radiolysis of zeolite A and SAPO molecular sieves containing Ag + as exchangeable cations. The pulsed EPR spectroscopy has been applied for studying the local environment of silver cluster in order to understand the mechanism of cluster formation and stabilization. the electron spin echo modulation (ESEM) results on Ag 6 n+ cluster in dehydration zeolite A indicate that the hexameric silver is stabilized only in sodalite cages which are surrounded by α-cages containing no water molecules. Trimeric silver clusters formed in hydrated A zeolites strongly interact with water, thus the paramagnetic center can be considered as a cluster-water adduct. In SAPO-molecular sieves, silver clusters are formed only in the presence of adsorbed alcohol molecules. From ESEM it is determined that Ag 4 n+ in SAPO-42 is stabilized in α cages, where it is directly coordinated by two methanol molecules. Dimeric silver, Ag 2 + in SAPO-5 and SAPO-11 is located in 6-ring channels and interacts with three CH 3 OH molecules, each in different 10 ring or 12 ring channels. The differences of Ag 2 + stability in SAPO-5 and SAPO-11 are also discussed. (Author)

  8. Pulsed-High Field/High-Frequency EPR Spectroscopy

    Science.gov (United States)

    Fuhs, Michael; Moebius, Klaus

    Pulsed high-field/high-frequency electron paramagnetic resonance (EPR) spectroscopy is used to disentangle many kinds of different effects often obscured in continuous wave (cw) EPR spectra at lower magnetic fields/microwave frequencies. While the high magnetic field increases the resolution of G tensors and of nuclear Larmor frequencies, the high frequencies allow for higher time resolution for molecular dynamics as well as for transient paramagnetic intermediates studied with time-resolved EPR. Pulsed EPR methods are used for example for relaxation-time studies, and pulsed Electron Nuclear DOuble Resonance (ENDOR) is used to resolve unresolved hyperfine structure hidden in inhomogeneous linewidths. In the present article we introduce the basic concepts and selected applications to structure and mobility studies on electron transfer systems, reaction centers of photosynthesis as well as biomimetic models. The article concludes with an introduction to stochastic EPR which makes use of an other concept for investigating resonance systems in order to increase the excitation bandwidth of pulsed EPR. The limited excitation bandwidth of pulses at high frequency is one of the main limitations which, so far, made Fourier transform methods hardly feasible.

  9. Nanosecond time-resolved EPR in pulse radiolysis via the spin echo method

    International Nuclear Information System (INIS)

    Trifunac, A.D.; Norris, J.R.; Lawler, R.G.

    1979-01-01

    The design and operation of a time-resolved electron spin echo spectrometer suitable for detecting transient radicals produced by 3 MeV electron radiolysis is described. Two modes of operation are available: Field swept mode which generates a normal EPR spectrum and kinetic mode in which the time dependence of a single EPR line is monitored. Techniques which may be used to minimize the effects of nonideal microwave pulses and overlapping sample tube signals are described. The principal advantages of the spin echo method over other time-resolved EPR methods are: (1) Improved time resolution (presently approx.30--50 nsec) allows monitoring of fast changes in EPR signals of transient radicals, (2) Lower susceptibility to interference between the EPR signal and the electron beam pulse at short times, and (3) Lack of dependence of transient signals on microwave field amplitude or static field inhomogeneity at short times. The performance of the instrument is illustrated using CIDEP from acetate radical formed in pulsed radiolysis of aqueous solutions of potassium acetate. The relaxation time and CIDEP enhancement factor obtained for this radical using the spin echo method compare favorably with previous determinations using direct detection EPR. Radical decay rates yield estimates of initial radical concentrations of 10 -4 10 -3 M per electron pulse. The Bloch equations are solved to give an expression for the echo signal for samples exhibiting CIDEP using arbitrary microwave pulse widths and distributions of Larmor frequencies. Conditions are discussed under which the time-dependent signal would be distorted by deviations from an ideal nonselective 90 0 --tau--180 0 pulse sequence

  10. Pulsed rf excited spectrometer having improved pulse width control

    International Nuclear Information System (INIS)

    1977-01-01

    RF excitation for a spectrometer is obtained by pulse width modulating an RF carrier to produce the desired broadband RF exciting spectrum. The RF excitation includes a train of composite RF pulses, each composite pulse having a primary pulse portion of a first RF phase and a second pulse portion of a second RF phase opposite that of the first. In this manner, the finite rise and fall times of the primary pulse portion are compensated for by the corresponding rise and fall times of the secondary pulse portion. The primary pulse portion is lengthened by an amount equal to the secondary pulse portion so that the secondary pulse portion cancels the added primary pulse portion. In a spectrometer, the compensating second pulse component removes certain undesired side bands of the RF excitation caused by the finite rise and fall times of the applied RF pulses. The compensating second pulse component removes certain undesired side bands associated with each of the resonant lines of the excited resonance spectrum of the sample under analysis, particularly for wide band RF excitation

  11. Pulse EPR distance measurements to study multimers and multimerisation

    Science.gov (United States)

    Ackermann, Katrin; Bode, Bela E.

    2018-06-01

    Pulse dipolar electron paramagnetic resonance (PD-EPR) has become a powerful tool for structural biology determining distances on the nanometre scale. Recent advances in hardware, methodology, and data analysis have widened the scope to complex biological systems. PD-EPR can be applied to systems containing lowly populated conformers or displaying large intrinsic flexibility, making them all but intractable for cryo-electron microscopy and crystallography. Membrane protein applications are of particular interest due to the intrinsic difficulties for obtaining high-resolution structures of all relevant conformations. Many drug targets involved in critical cell functions are multimeric channels or transporters. Here, common approaches for introducing spin labels for PD-EPR cause the presence of more than two electron spins per multimeric complex. This requires careful experimental design to overcome detrimental multi-spin effects and to secure sufficient distance resolution in presence of multiple distances. In addition to obtaining mere distances, PD-EPR can also provide information on multimerisation degrees allowing to study binding equilibria and to determine dissociation constants.

  12. A 5 tesla superconducting magnet and cryostats for an EPR/FMR spectrometer

    NARCIS (Netherlands)

    Reuvekamp, E.M.C.M.; Gerritsma, G.J.; ten Kate, Herman H.J.; van de Klundert, L.J.M.

    1988-01-01

    A description is given of the cryogenic part of an electron paramagnetic resonance (EPR)/ferromagnetic resonance (FMR) spectrometer using Ka-band (26.5-40 GHz) and U-band (40-60 GHz) frequencies for resonance measurements on large magnetic thin-films. The unit has two cryostats; the first has a

  13. New Developments in Spin Labels for Pulsed Dipolar EPR

    Directory of Open Access Journals (Sweden)

    Alistair J. Fielding

    2014-10-01

    Full Text Available Spin labelling is a chemical technique that enables the integration of a molecule containing an unpaired electron into another framework for study. Given the need to understand the structure, dynamics, and conformational changes of biomacromolecules, spin labelling provides a relatively non-intrusive technique and has certain advantages over X-ray crystallography; which requires high quality crystals. The technique relies on the design of binding probes that target a functional group, for example, the thiol group of a cysteine residue within a protein. The unpaired electron is typically supplied through a nitroxide radical and sterically shielded to preserve stability. Pulsed electron paramagnetic resonance (EPR techniques allow small magnetic couplings to be measured (e.g., <50 MHz providing information on single label probes or the dipolar coupling between multiple labels. In particular, distances between spin labels pairs can be derived which has led to many protein/enzymes and nucleotides being studied. Here, we summarise recent examples of spin labels used for pulse EPR that serve to illustrate the contribution of chemistry to advancing discoveries in this field.

  14. Active cancellation - A means to zero dead-time pulse EPR.

    Science.gov (United States)

    Franck, John M; Barnes, Ryan P; Keller, Timothy J; Kaufmann, Thomas; Han, Songi

    2015-12-01

    The necessary resonator employed in pulse electron paramagnetic resonance (EPR) rings after the excitation pulse and creates a finite detector dead-time that ultimately prevents the detection of signal from fast relaxing spin systems, hindering the application of pulse EPR to room temperature measurements of interesting chemical or biological systems. We employ a recently available high bandwidth arbitrary waveform generator (AWG) to produce a cancellation pulse that precisely destructively interferes with the resonant cavity ring-down. We find that we can faithfully detect EPR signal at all times immediately after, as well as during, the excitation pulse. This is a proof of concept study showcasing the capability of AWG pulses to precisely cancel out the resonator ring-down, and allow for the detection of EPR signal during the pulse itself, as well as the dead-time of the resonator. However, the applicability of this approach to conventional EPR experiments is not immediate, as it hinges on either (1) the availability of low-noise microwave sources and amplifiers to produce the necessary power for pulse EPR experiment or (2) the availability of very high conversion factor micro coil resonators that allow for pulse EPR experiments at modest microwave power. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Chirped Pulse Spectrometer Operating at 200 GHz

    Science.gov (United States)

    Hindle, Francis; Bray, Cédric; Hickson, Kevin; Fontanari, Daniele; Mouelhi, Meriem; Cuisset, Arnaud; Mouret, Gaël; Bocquet, Robin

    2018-01-01

    The combination of electronic sources operating at high frequencies and modern microwave instrumentation has enabled the recent development of chirped pulse spectrometers for the millimetre and THz bands. This type of instrument can operate at high resolution which is particularly suited to gas-phase rotational spectroscopy. The construction of a chirped pulse spectrometer operating at 200 GHz is described in detail while attention is paid to the phase stability and the data accumulation over many cycles. Validation using carbonyl sulphide has allowed the detection limit of the instrument to be established as function of the accumulation. A large number of OCS transitions were identified using a 10-GHz chirped pulse and include the six most abundant isotopologues, the weakest line corresponding to the fundamental R(17) transition of 16O13C33S with a line strength of 4.3 × 10-26 cm-1/(molecule cm-2). The linearity of the system response for different degrees of data accumulation and transition line strength was confirmed over four orders of magnitudes. A simple analysis of the time-domain data was demonstrated to provide the line-broadening coefficient without the need for conversion by a Fourier transform. Finally, the pulse duration is discussed and optimal values are given for both Doppler-limited and collisional regimes.

  16. Fast neutron spectrometer with pulse shape discrimination

    International Nuclear Information System (INIS)

    Verbitsky, S.S.

    1978-01-01

    A fast neutron spectrometer with a stilbene single crystal designed to operate at high pulsed count rate has been described. Making use of identification and rejection of events, accompanied by pile-up, allowed to increase permissible count rates by an order of magnitude. The results of energy dependence of signal amplitude and shape relative anisotropy in stilbene in the range 4-10 and 2-8 MeV respectively have been presented. Taking into account anisotropy of the detector-scintillation properties allowed to improve particle discrimination. (Auth.)

  17. Dye laser spectrometer for the analysis of pulsed vacuum arcs

    International Nuclear Information System (INIS)

    Hargis, P.J. Jr.; Robertson, M.M.

    1975-01-01

    A pulsed dye laser spectrometer which is used to obtain detailed single shot spectroscopic measurements of the plasma in a pulsed vacuum arc was developed. The capabilities of this spectrometer are indicated by the detection of laser induced fluorescence signals from 10 6 neutral Ti atoms in the plasma of a pulsed vacuum arc with a Ti anode. (U.S.)

  18. Structure and dynamics of paramagnetic transients by pulsed EPR and NMR detection of nuclear resonance

    International Nuclear Information System (INIS)

    Trifunac, A.D.

    1981-01-01

    Structure and dynamics of transient radicals in pulse radiolysis can be studied by time resolved EPR and NMR techniques. EPR study of kinetics and relaxation is illustrated. The NMR detection of nuclear resonance in transient radicals is a new method which allows the study of hyperfine coupling, population dynamics, radical kinetics, and reaction mechanism. 9 figures

  19. Arbitrary waveform modulated pulse EPR at 200 GHz

    Science.gov (United States)

    Kaminker, Ilia; Barnes, Ryan; Han, Songi

    2017-06-01

    We report here on the implementation of arbitrary waveform generation (AWG) capabilities at ∼200 GHz into an Electron Paramagnetic Resonance (EPR) and Dynamic Nuclear Polarization (DNP) instrument platform operating at 7 T. This is achieved with the integration of a 1 GHz, 2 channel, digital to analog converter (DAC) board that enables the generation of coherent arbitrary waveforms at Ku-band frequencies with 1 ns resolution into an existing architecture of a solid state amplifier multiplier chain (AMC). This allows for the generation of arbitrary phase- and amplitude-modulated waveforms at 200 GHz with >150 mW power. We find that the non-linearity of the AMC poses significant difficulties in generating amplitude-modulated pulses at 200 GHz. We demonstrate that in the power-limited regime of ω1 10 MHz) spin manipulation in incoherent (inversion), as well as coherent (echo formation) experiments. Highlights include the improvement by one order of magnitude in inversion bandwidth compared to that of conventional rectangular pulses, as well as a factor of two in improvement in the refocused echo intensity at 200 GHz.

  20. Pulsed EPR studies of small reactive radicals produced by ionizing radiation

    International Nuclear Information System (INIS)

    Lawler, R.G.

    1985-01-01

    For several years we have participated in a collaborative research effort to apply the pulsed EPR-pulse radiolysis technique to several problems associated with the dynamics of small reactive radicals formed during radiolysis of aqueous solutions using 3 MeV electrons from a Van de Graaff accelerator. We will discuss experimental techniques and applications arising from this work, with particular emphasis on problems requiring high initial radical concentrations and EPR time resolution of one microsecond or better. 2 figs., 2 tabs

  1. Pulsed EPR analysis of tooth enamel samples exposed to UV and {gamma}-radiations

    Energy Technology Data Exchange (ETDEWEB)

    Marrale, M., E-mail: marrale@unipa.it [Dipartimento di Fisica, Universita di Palermo, Viale delle Scienze, Edificio 18, 90128 Palermo (Italy); Gruppo V Sezione INFN, Catania, Italy and Unita CNISM, Palermo (Italy); Longo, A.; Brai, M. [Dipartimento di Fisica, Universita di Palermo, Viale delle Scienze, Edificio 18, 90128 Palermo (Italy); Gruppo V Sezione INFN, Catania (Italy) and Unita CNISM, Palermo (Italy); Barbon, A.; Brustolon, M. [Dipartimento di Scienze Chimiche, Universita degli Studi di Padova, Via Marzolo 1, 35131 Padova (Italy); Fattibene, P. [Istituto Superiore di Sanita, Viale Regina Elena 299, 00161 Rome (Italy)

    2011-09-15

    The electron paramagnetic resonance (EPR) spectroscopy is widely applied for retrospective dosimetric purposes by means of quantitative detection of radicals in tooth enamel and bone samples. In this work we report a study by cw and pulsed EPR on two samples of human tooth enamel respectively irradiated by UV (254 nm) and {gamma}-exposed. The continuous wave (cw) EPR spectra have shown the usual presence in both samples of two types of CO{sub 2}{sup -} radicals, with axial and orthorombic g tensors. We have obtained the electron spin echo detected EPR (ED-EPR) spectra at 80 K of the two samples, and we have shown that they are suitable to mark the difference between the effects produced by the different irradiations. At low temperature the contribution to the ED-EPR spectrum of the mobile radical with the axial g tensor is still present in the UV irradiated sample, but not in the {gamma}-irradiated one, where its dynamics is too slow to average the g tensor. We have moreover studied the two-pulse electron spin echo decay on varying the microwave power, a well established method for measuring the Instantaneous Diffusion. We have found that the spectral diffusion parameter is almost the same for both radiation types, whereas the Instantaneous Diffusion is significantly larger for {gamma}-exposed samples than for UV irradiated ones. This difference is due to a higher local microscopic concentration of free radicals for samples irradiated with {gamma} photons.

  2. FERDO/FERD, Unfolding of Pulse-Height Spectrometer Spectra

    International Nuclear Information System (INIS)

    Rust, B.W.; Ingersoll, D.T.; Burrus, W.R.

    1985-01-01

    1 - Description of problem or function: FERDO and FERD are unfolding codes which can be used to correct observed pulse-height distributions for the non-ideal response of a pulse-height spectrometer or to solve poorly conditioned linear equations. 2 - Method of solution: It is assumed that the response of the spectrometer is given by Ax = b, where A is the spectrometer response function matrix, x is the unknown spectrum, and b is the pulse-height distribution. FERDO does not resolve directly for x but instead solves for p = Wx, where W is a 'window function matrix'. Typically, W is the resolution function of an ideal spectrometer which has a single Gaussian response. The effective resolution of the unfolding solution may be varied by the choice of W. Confidence intervals are found for each element of the solution p

  3. Two-dimensional 220 MHz Fourier transform EPR imaging

    International Nuclear Information System (INIS)

    Placidi, Giuseppe; Brivati, John A.; Alecci, Marcello; Testa, Luca; Sotgiu, Antonello

    1998-01-01

    In the last decade radiofrequency continuous-wave EPR spectrometers have been developed to detect and localize free radicals in vivo. Only recently, pulsed radiofrequency EPR spectrometers have been described for imaging applications with small samples. In the present work, we show the first two-dimensional image obtained at 220 MHz on a large phantom (40 ml) that simulates typical conditions of in vivo EPR imaging. This pulsed EPR apparatus has the potential to make the time required for three-dimensional imaging compatible with the biological half-life of normally used paramagnetic probes. (author)

  4. Pulse Double-Resonance EPR Techniques for the Study of Metallobiomolecules.

    Science.gov (United States)

    Cox, Nicholas; Nalepa, Anna; Pandelia, Maria-Eirini; Lubitz, Wolfgang; Savitsky, Anton

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy exploits an intrinsic property of matter, namely the electron spin and its related magnetic moment. This can be oriented in a magnetic field and thus, in the classical limit, acts like a little bar magnet. Its moment will align either parallel or antiparallel to the field, giving rise to different energies (termed Zeeman splitting). Transitions between these two quantized states can be driven by incident microwave frequency radiation, analogous to NMR experiments, where radiofrequency radiation is used. However, the electron Zeeman interaction alone provides only limited information. Instead, much of the usefulness of EPR is derived from the fact that the electron spin also interacts with its local magnetic environment and thus can be used to probe structure via detection of nearby spins, e.g., NMR-active magnetic nuclei and/or other electron spin(s). The latter is exploited in spin labeling techniques, an exciting new area in the development of noncrystallographic protein structure determination. Although these interactions are often smaller than the linewidth of the EPR experiment, sophisticated pulse EPR methods allow their detection. A number of such techniques are well established today and can be broadly described as double-resonance methods, in which the electron spin is used as a reporter. Below we give a brief description of pulse EPR methods, particularly their implementation at higher magnetic fields, and how to best exploit them for studying metallobiomolecules. © 2015 Elsevier Inc. All rights reserved.

  5. Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

    Science.gov (United States)

    Möser, J; Lips, K; Tseytlin, M; Eaton, G R; Eaton, S S; Schnegg, A

    2017-08-01

    X-band rapid-scan EPR was implemented on a commercially available Bruker ELEXSYS E580 spectrometer. Room temperature rapid-scan and continuous-wave EPR spectra were recorded for amorphous silicon powder samples. By comparing the resulting signal intensities the feasibility of performing quantitative rapid-scan EPR is demonstrated. For different hydrogenated amorphous silicon samples, rapid-scan EPR results in signal-to-noise improvements by factors between 10 and 50. Rapid-scan EPR is thus capable of improving the detection limit of quantitative EPR by at least one order of magnitude. In addition, we provide a recipe for setting up and calibrating a conventional pulsed and continuous-wave EPR spectrometer for rapid-scan EPR. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. A pulse spectrometer for NMR measurements on magnetically ordered materials

    International Nuclear Information System (INIS)

    Englich, J.; Pikner, B.; Sedlak, B.

    1975-01-01

    A simple design of a pulse nuclear magnetic resonance spectrometer is described. The spectrometer permits spin echo measurements on magnetically ordered substances. It operates in the frequency range 10 to 130 MHz, but this basic range can be extended by a replacement of the compact radiofrequency unit. The transmitter gives radiofrequency pulses with an amplitude of up to 1 kV on the coil with the investigated sample. The pulse programmer makes possible relaxation measurements in a time interval of 10 -5 to 10 -1 s. Attention was devoted to obtaining a maximum signal-to-noise ratio in the whole frequency range. Sensitivity of the spectrometer is demonstrated by spin echo measurement on pure iron powder. (author)

  7. CW- and pulsed-EPR of carbonaceous matter in primitive meteorites: solving a lineshape paradox.

    Science.gov (United States)

    Delpoux, Olivier; Gourier, Didier; Binet, Laurent; Vezin, Hervé; Derenne, Sylvie; Robert, François

    2008-05-01

    Insoluble organic matter (IOM) of Orgueil and Tagish Lake meteorites are studied by CW-EPR and pulsed-EPR spectroscopies. The EPR line is due to polycyclic paramagnetic moieties concentrated in defect-rich regions of the IOM, with concentrations of the order of 4x10(19) spin/g. CW-EPR reveals two types of paramagnetic defects: centres with S=1/2, and centres with S=0 ground state and thermally accessible triple state S=1. In spite of the Lorentzian shape of the EPR and its narrowing upon increasing the spin concentration, the EPR line is not in the exchange narrowing regime as previously deduced from multi-frequency CW-EPR [L. Binet, D. Gourier, Appl. Magn. Reson. 30 (2006) 207-231]. It is inhomogeneously broadened as demonstrated by the presence of nuclear modulations in the spin-echo decay. The line narrowing, similar to an exchange narrowing effect, is the result of an increasing contribution of the narrow line of the triplet state centres in addition to the broader line of doublet states. Hyperfine sublevel correlation spectroscopy (HYSCORE) of hydrogen and (13)C nuclei indicates that IOM* centres are small polycyclic moieties that are moderately branched with aliphatic chains, as shown by the presence of aromatic hydrogen atoms. On the contrary the lack of such aromatic hydrogen in triplet states suggests that these radicals are most probably highly branched. Paramagnetic centres are considerably enriched in deuterium, with D/H approximately 1.5+/-0.5x10(-2) of the order of values existing in interstellar medium.

  8. CW- and pulsed-EPR of carbonaceous matter in primitive meteorites: Solving a lineshape paradox

    Science.gov (United States)

    Delpoux, Olivier; Gourier, Didier; Binet, Laurent; Vezin, Hervé; Derenne, Sylvie; Robert, François

    2008-05-01

    Insoluble organic matter (IOM) of Orgueil and Tagish Lake meteorites are studied by CW-EPR and pulsed-EPR spectroscopies. The EPR line is due to polycyclic paramagnetic moieties concentrated in defect-rich regions of the IOM, with concentrations of the order of 4 × 10 19 spin/g. CW-EPR reveals two types of paramagnetic defects: centres with S = 1/2, and centres with S = 0 ground state and thermally accessible triple state S = 1. In spite of the Lorentzian shape of the EPR and its narrowing upon increasing the spin concentration, the EPR line is not in the exchange narrowing regime as previously deduced from multi-frequency CW-EPR [L. Binet, D. Gourier, Appl. Magn. Reson. 30 (2006) 207-231]. It is inhomogeneously broadened as demonstrated by the presence of nuclear modulations in the spin-echo decay. The line narrowing, similar to an exchange narrowing effect, is the result of an increasing contribution of the narrow line of the triplet state centres in addition to the broader line of doublet states. Hyperfine sublevel correlation spectroscopy (HYSCORE) of hydrogen and 13C nuclei indicates that IOM rad centres are small polycyclic moieties that are moderately branched with aliphatic chains, as shown by the presence of aromatic hydrogen atoms. On the contrary the lack of such aromatic hydrogen in triplet states suggests that these radicals are most probably highly branched. Paramagnetic centres are considerably enriched in deuterium, with D/H ≈ 1.5 ± 0.5 × 10 -2 of the order of values existing in interstellar medium.

  9. Ion Channel Conformation and Oligomerization Assessment by Site-Directed Spin Labeling and Pulsed-EPR.

    Science.gov (United States)

    Pliotas, Christos

    2017-01-01

    Mechanosensitive (MS) ion channels are multimeric integral membrane proteins that respond to increased lipid bilayer tension by opening their nonselective pores to release solutes and relieve increased cytoplasmic pressure. These systems undergo major conformational changes during gating and the elucidation of their mechanism requires a deep understanding of the interplay between lipids and proteins. Lipids are responsible for transmitting lateral tension to MS channels and therefore play a key role in obtaining a molecular-detail model for mechanosensation. Site-directed spin labeling combined with electron paramagnetic resonance (EPR) spectroscopy is a powerful spectroscopic tool in the study of proteins. The main bottleneck for its use relates to challenges associated with successful isolation of the protein of interest, introduction of paramagnetic labels on desired sites, and access to specialized instrumentation and expertise. The design of sophisticated experiments, which combine a variety of existing EPR methodologies to address a diversity of specific questions, require knowledge of the limitations and strengths, characteristic of each particular EPR method. This chapter is using the MS ion channels as paradigms and focuses on the application of different EPR techniques to ion channels, in order to investigate oligomerization, conformation, and the effect of lipids on their regulation. The methodology we followed, from the initial strategic selection of mutants and sample preparation, including protein purification, spin labeling, reconstitution into lipid mimics to the complete set-up of the pulsed-EPR experiments, is described in detail. © 2017 Elsevier Inc. All rights reserved.

  10. Taking the Pulse of Protein Interactions by EPR Spectroscopy

    OpenAIRE

    Cafiso, David S.

    2012-01-01

    An article by Gaffney et al. in this issue establishes a method using pulse electron paramagnetic resonance spectroscopy to determine the location of protein substrates or binding partners with high precision.

  11. Structure and dynamics of paramagnetic transients by pulsed EPR and NMR detection of nuclear resonance. [Pulse radiolysis of methanol in D/sub 2/O

    Energy Technology Data Exchange (ETDEWEB)

    Trifunac, A.D.

    1981-01-01

    Structure and dynamics of transient radicals in pulse radiolysis can be studied by time resolved EPR and NMR techniques. EPR study of kinetics and relaxation is illustrated. The NMR detection of nuclear resonance in transient radicals is a new method which allows the study of hyperfine coupling, population dynamics, radical kinetics, and reaction mechanism. 9 figures.

  12. SPIDYAN, a MATLAB library for simulating pulse EPR experiments with arbitrary waveform excitation.

    Science.gov (United States)

    Pribitzer, Stephan; Doll, Andrin; Jeschke, Gunnar

    2016-02-01

    Frequency-swept chirp pulses, created with arbitrary waveform generators (AWGs), can achieve inversion over a range of several hundreds of MHz. Such passage pulses provide defined flip angles and increase sensitivity. The fact that spectra are not excited at once, but single transitions are passed one after another, can cause new effects in established pulse EPR sequences. We developed a MATLAB library for simulation of pulse EPR, which is especially suited for modeling spin dynamics in ultra-wideband (UWB) EPR experiments, but can also be used for other experiments and NMR. At present the command line controlled SPin DYnamics ANalysis (SPIDYAN) package supports one-spin and two-spin systems with arbitrary spin quantum numbers. By providing the program with appropriate spin operators and Hamiltonian matrices any spin system is accessible, with limits set only by available memory and computation time. Any pulse sequence using rectangular and linearly or variable-rate frequency-swept chirp pulses, including phase cycling can be quickly created. To keep track of spin evolution the user can choose from a vast variety of detection operators, including transition selective operators. If relaxation effects can be neglected, the program solves the Liouville-von Neumann equation and propagates spin density matrices. In the other cases SPIDYAN uses the quantum mechanical master equation and Liouvillians for propagation. In order to consider the resonator response function, which on the scale of UWB excitation limits bandwidth, the program includes a simple RLC circuit model. Another subroutine can compute waveforms that, for a given resonator, maintain a constant critical adiabaticity factor over the excitation band. Computational efficiency is enhanced by precomputing propagator lookup tables for the whole set of AWG output levels. The features of the software library are discussed and demonstrated with spin-echo and population transfer simulations. Copyright © 2016

  13. Enhanced accuracy of the microwave field strength measurement in a CW-EPR by pulsed modulation technique

    Science.gov (United States)

    Rakvin, B.; Carić, D.; Kveder, M.

    2018-02-01

    The microwave magnetic field strength, B1, in the cavity of a conventional continuous wave electron paramagnetic resonance, CW-EPR, spectrometer was measured by employing modulation sidebands, MS, in the EPR spectrum. MS spectrum in CW-EPR is produced by applying the modulation frequency, ωrf, which exceeds the linewidth, δB, given in frequency units. An amplitude-modulated CW-EPR, AM-CW-EPR, was selected as detection method. Theoretical description of AM-CW-EPR spectrum was modified by adding Bloch-Siegert-like shift obtained by taking into account the cumulative effect of the non-resonant interactions between the driving fields and the spin system. This approach enables to enhance the precision of B1 measurement. In order to increase the sensitivity of the method when saturation effects, due to higher intensity of B1, decrease the resolution of AM-CW-EPR spectrum, detection at the second harmonic of CW-EPR has been employed.

  14. Enhanced accuracy of the microwave field strength measurement in a CW-EPR by pulsed modulation technique.

    Science.gov (United States)

    Rakvin, B; Carić, D; Kveder, M

    2018-02-01

    The microwave magnetic field strength, B 1 , in the cavity of a conventional continuous wave electron paramagnetic resonance, CW-EPR, spectrometer was measured by employing modulation sidebands, MS, in the EPR spectrum. MS spectrum in CW-EPR is produced by applying the modulation frequency, ω rf , which exceeds the linewidth, δB, given in frequency units. An amplitude-modulated CW-EPR, AM-CW-EPR, was selected as detection method. Theoretical description of AM-CW-EPR spectrum was modified by adding Bloch-Siegert-like shift obtained by taking into account the cumulative effect of the non-resonant interactions between the driving fields and the spin system. This approach enables to enhance the precision of B 1 measurement. In order to increase the sensitivity of the method when saturation effects, due to higher intensity of B 1 , decrease the resolution of AM-CW-EPR spectrum, detection at the second harmonic of CW-EPR has been employed. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Pulsed EPR studies of Phosphorus shallow donors in diamond and SiC

    International Nuclear Information System (INIS)

    Isoya, J.; Katagiri, M.; Umeda, T.; Koizumi, S.; Kanda, H.; Son, N.T.; Henry, A.; Gali, A.; Janzen, E.

    2006-01-01

    Phosphorus shallow donors having the symmetry lower than T d are studied by pulsed EPR. In diamond:P and 3C-SiC:P, the symmetry is lowered to D 2d and the density of the donor wave function on the phosphorus atom exhibits a predominant p-character. In 4H-SiC:P with the site symmetry of C 3v , the A 1 ground state of the phosphorus donors substituting at the quasi-cubic site of silicon shows an axial character of the distribution of the donor wave function in the vicinity of the phosphorus atom

  16. Solid state low power pulsed NMR spectrometer system

    International Nuclear Information System (INIS)

    Nadkarni, S.S.; Parthasarathy, T.G.; Menon, M.P.S.; Hannurkar, P.R.

    1981-01-01

    A pulsed nuclear magnetic resonance spectrometer system is described for relaxation time studies on solid and liquid samples. The spectrometer design is fully solid state and a special microcomputer interface is incorporated for automatic evaluation of the relaxation times. The prototype system has been designed to operate at 9 MHz, but the modular concept used in the construction permits operation at any frequency in the range 5-10 MHz. The system has a recovery time of 15 micro seconds at 9 MHz. The range of measurement for the spin-lattice relaxation time is 0.1 millisecond to 1000 seconds; for spin-spin relaxation time, the range is 14μ seconds to 100 milliseconds. (author)

  17. Structures and reaction pathways of the molybdenum centres of sulfite-oxidizing enzymes by pulsed EPR spectroscopy.

    Science.gov (United States)

    Enemark, John H; Astashkin, Andrei V; Raitsimring, Arnold M

    2008-12-01

    SOEs (sulfite-oxidizing enzymes) are physiologically vital and occur in all forms of life. During the catalytic cycle, the five-co-ordinate square pyramidal oxo-molybdenum active site passes through the Mo(V) state, and intimate details of the structure can be obtained from variable frequency pulsed EPR spectroscopy through the hyperfine and nuclear quadrupole interactions of nearby magnetic nuclei. By employing variable spectrometer operational frequencies, it is possible to optimize the measurement conditions for difficult quadrupolar nuclei of interest (e.g. (17)O, (33)S, (35)Cl and (37)Cl) and to simplify the interpretation of the spectra. Isotopically labelled model Mo(V) compounds provide further insight into the electronic and geometric structures and chemical reactions of the enzymes. Recently, blocked forms of SOEs having co-ordinated sulfate, the reaction product, were detected using (33)S (I=3/2) labelling. This blocking of product release is a possible contributor to fatal human sulfite oxidase deficiency in young children.

  18. Water accessibility in a membrane-inserting peptide comparing Overhauser DNP and pulse EPR methods

    Energy Technology Data Exchange (ETDEWEB)

    Segawa, Takuya F., E-mail: takuya.segawa@alumni.ethz.ch; Doppelbauer, Maximilian; Garbuio, Luca; Doll, Andrin; Polyhach, Yevhen O.; Jeschke, Gunnar, E-mail: gjeschke@ethz.ch [Laboratory of Physical Chemistry, ETH Zurich, Vladimir-Prelog-Weg 2, CH-8093 Zurich (Switzerland)

    2016-05-21

    Water accessibility is a key parameter for the understanding of the structure of biomolecules, especially membrane proteins. Several experimental techniques based on the combination of electron paramagnetic resonance (EPR) spectroscopy with site-directed spin labeling are currently available. Among those, we compare relaxation time measurements and electron spin echo envelope modulation (ESEEM) experiments using pulse EPR with Overhauser dynamic nuclear polarization (DNP) at X-band frequency and a magnetic field of 0.33 T. Overhauser DNP transfers the electron spin polarization to nuclear spins via cross-relaxation. The change in the intensity of the {sup 1}H NMR spectrum of H{sub 2}O at a Larmor frequency of 14 MHz under a continuous-wave microwave irradiation of the nitroxide spin label contains information on the water accessibility of the labeled site. As a model system for a membrane protein, we use the hydrophobic α-helical peptide WALP23 in unilamellar liposomes of DOPC. Water accessibility measurements with all techniques are conducted for eight peptides with different spin label positions and low radical concentrations (10–20 μM). Consistently in all experiments, the water accessibility appears to be very low, even for labels positioned near the end of the helix. The best profile is obtained by Overhauser DNP, which is the only technique that succeeds in discriminating neighboring positions in WALP23. Since the concentration of the spin-labeled peptides varied, we normalized the DNP parameter ϵ, being the relative change of the NMR intensity, by the electron spin concentration, which was determined from a continuous-wave EPR spectrum.

  19. Pulsed laser photoacoustic spectrometer for study of solid materials

    International Nuclear Information System (INIS)

    Patel, N.D.; Kartha, V.B.

    1991-01-01

    The technique of photoacoustic spectroscopy has wide applications bacause it is extremely sensitive, and can be used to obtain spectra in wide spectral range for solids, liquids, gases, solutions, crystals etc. which may be usually difficult by conventional methods. For studying a variety of materials, a pulsed laser photoacoustic spectrometer has been set up in the laboratory. The report discusses the design and performance of the instrument. Some of the spectra of materials like Nd 2 O 9 powder, Nd-YAG crystal, CoCl 2 6H 2 O etc. are shown. A detailed discussion on assignment of the spectra of Nd-YAG is also presented. (author). 4 refs., 5 figs., 1 tab

  20. The simulation of pulsed heater for a sampling system for the ion mobility spectrometer

    International Nuclear Information System (INIS)

    Malkin, Evgeniy

    2011-01-01

    The development of the sampling device with pulsed heating of the intermediate carrier for ion mobility spectrometer is described in this article. Numerical simulation of a pulse heater structure of is presented. The design of the sampling device using a pulsed heating of the intermediate carrier is developed. Experimental results of approval of the sampling device are presented.

  1. Pulse radiolysis of alkanes: a time-resolved EPR study - Part I. Alkyl radicals

    International Nuclear Information System (INIS)

    Shkrob, I.A.; Trifunac, A.D.

    1995-01-01

    Time-resolved EPR was applied to detect short-lived alkyl radicals in pulse radiolysis of liquid alkanes. Two problems were addressed: (i) the mechanism of radical formation and (ii) the mechanism of chemically-induced spin polarization in these radicals. (i) The ratio of yields of penultimate and interior radicals in n-alkanes at the instant of their generation was found to be ≅ 1.25 times greater than the statistical quantity. This higher-than-statistical production of penultimate radicals indicates that the proton transfer reaction involving excited radical cations must be a prevailing route of radical generation. The relative yields of hydrogen abstraction and fragmentation for various branched alkanes are estimated. It is concluded that the fragmentation occurs prior to the formation of radicals in an excited precursor species. (ii) The analysis of spin-echo kinetics in n-alkanes suggests that the alkyl radicals gain the emissive polarization in spur reactions. This initial polarization increases with shortening of the aliphatic chain. We suggest that the origin of this polarization is the ST mechanism operating in the pairs of alkyl radicals and hydrogen atoms generated in dissociation of excited alkane molecules. It is also found that a long-chain structure of alkyl radicals results in much higher rate of Heisenberg spin exchange relative to the recombination rate (up to 30 times). That suggests prominent steric effects in recombination or the occurrence of through-chain electron exchange. The significance of these results in the context of cross-linking in polyethylene and higher paraffins is discussed. (Author)

  2. An imaging proton spectrometer for short-pulse laser plasma experiments

    International Nuclear Information System (INIS)

    Chen Hui; Hazi, A. U.; Maren, R. van; Chen, S. N.; Le Pape, S.; Rygg, J. R.; Shepherd, R.; Fuchs, J.; Gauthier, M.

    2010-01-01

    The ultraintense short pulse laser pulses incident on solid targets can generate energetic protons. In addition to their potentially important applications such as in cancer treatments and proton fast ignition, these protons are essential to understand the complex physics of intense laser plasma interaction. To better characterize these laser-produced protons, we designed and constructed a novel spectrometer that will not only measure proton energy distribution with high resolution but also provide its angular characteristics. The information obtained from this spectrometer compliments those from commonly used diagnostics including radiochromic film packs, CR39 nuclear track detectors, and nonimaging magnetic spectrometers. The basic characterizations and sample data from this instrument are presented.

  3. An imaging proton spectrometer for short-pulse laser plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Chen Hui; Hazi, A. U.; Maren, R. van; Chen, S. N.; Le Pape, S.; Rygg, J. R.; Shepherd, R. [Lawrence Livermore National Laboratory, Livemore, California 94551 (United States); Fuchs, J.; Gauthier, M. [LULI Ecole Polytechnique, 91128 Palaiseau Cedex (France)

    2010-10-15

    The ultraintense short pulse laser pulses incident on solid targets can generate energetic protons. In addition to their potentially important applications such as in cancer treatments and proton fast ignition, these protons are essential to understand the complex physics of intense laser plasma interaction. To better characterize these laser-produced protons, we designed and constructed a novel spectrometer that will not only measure proton energy distribution with high resolution but also provide its angular characteristics. The information obtained from this spectrometer compliments those from commonly used diagnostics including radiochromic film packs, CR39 nuclear track detectors, and nonimaging magnetic spectrometers. The basic characterizations and sample data from this instrument are presented.

  4. Pulsed coherent spectrometer of nuclear magnetic and nuclear quadrupole resonance

    International Nuclear Information System (INIS)

    Karnachev, A.S.; Solov'ev, E.E.

    1996-01-01

    The spectrometer intended for studies on solid bodies was created on the basis of the X1-48 device for investigation of amplitude-frequency characteristics with the frequency range of 5-100 MHz, the receiver sensitivity by the signal-noise ratio at the outlet of 12 dB not worse than 0.5 μV and the feed-up capacity up to 80 W. The X1-48 minimal remodeling made it possible to use it in the spectrometer system as a signal feed-up source and measurer of the amplitude-frequency characteristic of the spectrometer receiver tract. 12 refs., 11 figs

  5. Spin states of reduced fullerenes (C60 and C120O) by CW and pulsed EPR

    International Nuclear Information System (INIS)

    Boas, J.F.; Drew, S.C.; Pilbrow, J.R.; Boyd, P.D.W.; Paul, P.; Reed, C.A.; Sun, D.

    2003-01-01

    Full text: The ESTN (Electron Spin Transient Nutation) EPR (Electron Paramagnetic Resonance) experiments reported at Wagga 2002 showed that the spin states of the reduced fullerenes C 120 O (2-), C 120 O (3-) and C 120 O (4-) were S = 1, S = 1/2 and S = 1 respectively. Further experiments using CW (Continuous Wave) EPR have confirmed the results of Paul et al. and have now shown that these states are the ground states of these anions. In the case of C 60 (3-), the recent CW and ESTN EPR experiments have shown that the electronic ground state of this anion is S = 1/2. The observation of ground states of low multiplicity for these anions is contrary to expectations based on MO calculations and the application of Hund's rules. A series of CW EPR experiments on C 60 (3-) have shown that some previous results may need to be re-interpreted. This arises from the delineation of the effects of microwave power, modulation amplitude and frequency, sample temperature and freezing rate on the EPR spectrum which is the combination of a broad line, attributed to C 60 (3-), and a 'spike' attributed to C 120 O impurities and other oxygen related species. Our results cast doubt on the existence of Jahn-Teller effects at low temperatures and of a low-lying spin quartet excited state

  6. Pulsed EPR Spin-probe study of intracellular glasses in seed and pollen

    NARCIS (Netherlands)

    Buitink, J.; Dzuba, S.A.; Hoekstra, F.A.; Tsvetkov, Y.D.

    2000-01-01

    EPR spectra of 3-carboxy-proxyl (CP) in dry biological tissues exhibited a temperature-dependent change in the principal value A′zz of the hyperfine interaction tensor. The A′zz value changed sharply at a particular temperature that was dependent on water content. At elevated water contents, the

  7. EPR spectroscopy at DNP conditions

    International Nuclear Information System (INIS)

    Heckmann, J.; Goertz, St.; Meyer, W.; Radtke, E.; Reicherz, G.

    2004-01-01

    In terms of dynamic nuclear polarization (DNP) studies and systematic target material research it is crucial to know the EPR lineshape of the DNP relevant paramagnetic centers. Therefore in Bochum an EPR spectrometer has been implemented into the 4 He evaporation DNP facility in order to perform EPR studies at DNP conditions (B=2.5 T, T=1 K). The spectrometer hardware and performance as well as first results are presented

  8. A passive dual-circulator based transmit/receive switch for use with reflection resonators in pulse EPR

    Science.gov (United States)

    Subramanian, V. S.; Epel, Boris; Mailer, Colin; Halpern, Howard J.

    2009-01-01

    In order to protect the low noise amplifier (LNA) in the receive arm of a pulsed 250 MHz EPR bridge, it is necessary to install as much isolation as possible between the power exciting the spin system and the LNA when high power is present in the receive arm of the bridge, while allowing the voltage induced by the magnetization in the spin sample to be passed undistorted and undiminished to the LNA once power is reduced below the level that can cause a LNA damage. We discuss a combination of techniques to accomplish this involving the power-routing circulator in the bridge, a second circulator acting as an isolator with passive shunt PIN diodes immediately following the second circulator. The low resistance of the forward biased PIN diode passively generates an impedance mismatch at the second circulator output port during the high power excitation pulse and resonator ring down. The mismatch reflects the high power to the remaining port of the second circulator, dumping it into a system impedance matched load. Only when the power diminishes below the diode conduction threshold will the resistance of the PIN diode rise to a value much higher than the system impedance. This brings the device into conduction mode. We find that the present design passively limits the output power to 14 dBm independent of the input power. For high input power levels the isolation may exceed 60 dB. This level of isolation is sufficient to fully protect the LNA of pulse EPR bridge. PMID:20052312

  9. Characterization of Ultrafast Laser Pulses using a Low-dispersion Frequency Resolved Optical Grating Spectrometer

    Science.gov (United States)

    Whitelock, Hope; Bishop, Michael; Khosravi, Soroush; Obaid, Razib; Berrah, Nora

    2016-05-01

    A low dispersion frequency-resolved optical gating (FROG) spectrometer was designed to characterize ultrashort (non-colinear optical parametric amplifier. This instrument splits a laser pulse into two replicas with a 90:10 intensity ratio using a thin pellicle beam-splitter and then recombines the pulses in a birefringent medium. The instrument detects a wavelength-sensitive change in polarization of the weak probe pulse in the presence of the stronger pump pulse inside the birefringent medium. Scanning the time delay between the two pulses and acquiring spectra allows for characterization of the frequency and time content of ultrafast laser pulses, that is needed for interpretation of experimental results obtained from these ultrafast laser systems. Funded by the DoE-BES, Grant No. DE-SC0012376.

  10. Chirp echo Fourier transform EPR-detected NMR.

    Science.gov (United States)

    Wili, Nino; Jeschke, Gunnar

    2018-04-01

    A new ultra-wide band (UWB) pulse EPR method is introduced for observing all nuclear frequencies of a paramagnetic center in a single shot. It is based on burning spectral holes with a high turning angle (HTA) pulse that excites forbidden transitions and subsequent detection of the hole pattern by a chirp echo. We term this method Chirp Echo Epr SpectroscopY (CHEESY)-detected NMR. The approach is a revival of FT EPR-detected NMR. It yields similar spectra and the same type of information as electron-electron double resonance (ELDOR)-detected NMR, but with a multiplex advantage. We apply CHEESY-detected NMR in Q band to nitroxides and correlate the hyperfine spectrum to the EPR spectrum by varying the frequency of the HTA pulse. Furthermore, a selective π pulse before the HTA pulse allows for detecting hyperfine sublevel correlations between transitions of one nucleus and for elucidating the coupling regime, the same information as revealed by the HYSCORE experiment. This is demonstrated on hexaaquamanganese(II). We expect that CHEESY-detected NMR is generally applicable to disordered systems and that our results further motivate the development of EPR spectrometers capable of coherent UWB excitation and detection, especially at higher fields and frequencies. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.

  11. Chirp echo Fourier transform EPR-detected NMR

    Science.gov (United States)

    Wili, Nino; Jeschke, Gunnar

    2018-04-01

    A new ultra-wide band (UWB) pulse EPR method is introduced for observing all nuclear frequencies of a paramagnetic center in a single shot. It is based on burning spectral holes with a high turning angle (HTA) pulse that excites forbidden transitions and subsequent detection of the hole pattern by a chirp echo. We term this method Chirp Echo Epr SpectroscopY (CHEESY)-detected NMR. The approach is a revival of FT EPR-detected NMR. It yields similar spectra and the same type of information as electron-electron double resonance (ELDOR)-detected NMR, but with a multiplex advantage. We apply CHEESY-detected NMR in Q band to nitroxides and correlate the hyperfine spectrum to the EPR spectrum by varying the frequency of the HTA pulse. Furthermore, a selective π pulse before the HTA pulse allows for detecting hyperfine sublevel correlations between transitions of one nucleus and for elucidating the coupling regime, the same information as revealed by the HYSCORE experiment. This is demonstrated on hexaaquamanganese(II). We expect that CHEESY-detected NMR is generally applicable to disordered systems and that our results further motivate the development of EPR spectrometers capable of coherent UWB excitation and detection, especially at higher fields and frequencies.

  12. The performance of neutron scattering spectrometers at a long-pulse spallation source

    International Nuclear Information System (INIS)

    Pynn, R.

    1995-01-01

    The first conclusion the author wants to draw is that comparison of the performance of neutron scattering spectrometers at CW and pulsed sources is simpler for long-pulsed sources than it is for the short-pulse variety. Even though detailed instrument design and assessment will require Monte Carlo simulations (which have already been performed at Los Alamos for SANS and reflectometry), simple arguments are sufficient to assess the approximate performance of spectrometers at an LPSS and to support the contention that a 1 MW long-pulse source can provide attractive performance, especially for instrumentation designed for soft-condensed-matter science. Because coupled moderators can be exploited at such a source, its time average cold flux is equivalent to that of a research reactor with a power of about 15 MW, so only a factor of 4 gain from source pulsing is necessary to obtain performance that is comparable with the ILL. In favorable cases, the gain from pulsing can be even more than this, approaching the limit set by the peak flux, giving about 4 times the performance of the ILL. Because of its low duty factor, an LPSS provides the greatest performance gains for relatively low resolution experiments with cold neutrons. It should thus be considered complementary to short pulse sources which are most effective for high resolution experiments using thermal or epithermal neutrons

  13. High voltage pulse system for the streamer chamber supply of the GIBS spectrometer

    International Nuclear Information System (INIS)

    Aksinenko, V.D.; Glagoleva, N.S.; Dement'ev, E.A.; Kaminskij, N.I.; Matyushin, A.T.; Matyushin, V.T.; Rozhnyatovskaya, S.A.; Ryakhovskij, V.N.; Nurgozhin, N.N.; Khusainov, E.K.

    1987-01-01

    Results of development and testing of high voltage pulse system HVPS for the streamer chamber supply of the GIBS spectrometer are presented. HVPS consists of the following basic blocks: nanosecond pulse high voltage generator, high voltage charging supply, trigger generator, chamber parameter control devices, gas-oil vacuuming supply systems, auxiliary and fire-prevention devices. The system blocks are described. Experimental results of HVPC testing are presented. HVPC provides a reliable (10 5 operations) of streamer chamber supply with high voltage pulse parameters: amplitude - 500 kV, amplitude instability (0.5-1.5)%, pulse duration - 12 ns, delay time - 500 ns, delay instability (2.5-5)%, mean frequency of output a signals - 0.1 Hz

  14. The performance of neutron scattering spectrometers at a long-pulse spallation source

    International Nuclear Information System (INIS)

    Pynn, R.

    1997-01-01

    In this document the author considers the performance of a long pulse spallation source for those neutron scattering experiments that are usually performed with a monochromatic beam at a continuous wave (CW) source such as a nuclear reactor. The first conclusion drawn is that comparison of the performance of neutron scattering spectrometers at CW and pulsed sources is simpler for long-pulsed sources than it is for the short-pulse variety. Even though detailed instrument design and assessment will require Monte Carlo simulations (which have already been performed at Los Alamos for SANS and reflectometry), simple arguments are sufficient to assess the approximate performance of spectrometers at an LPSS and to support the contention that a 1 MW long-pulse source can provide attractive performance, especially for instrumentation designed for soft-condensed-matter science. Because coupled moderators can be exploited at such a source, its time average cold flux is equivalent to that of a research reactor with a power of about 15 MW, so only a factor of 4 gain from source pulsing is necessary to obtain performance that is comparable with the ILL. In favorable cases, the gain from pulsing can be even more than this, approaching the limit set by the peak flux, giving about 4 times the performance of the ILL. Because of its low duty factor, an LPSS provides the greatest performance gains for relatively low resolution experiments with cold neutrons. It should thus be considered complementary to short pulse sources which are most effective for high resolution experiments using thermal or epithermal neutrons

  15. Design of a pulsed angular selective electron gun for the KATRIN main spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Winzen, Daniel; Hannen, Volker; Ortjohann, Hans-Werner; Zacher, Michael; Weinheimer, Christian [Institut fuer Kernphysik, Westfaelische Wilhelms-Universitaet, Muenster (Germany); Collaboration: KATRIN-Collaboration

    2012-07-01

    The KATRIN (KArlsruhe TRItium Neutrino mass) experiment will study the tritium {beta}-spectrum near the endpoint of 18.6 keV, aiming to measure the mass of the electron antineutrino. Using an electrostatic retarding spectrometer (MAC-E-Filter), the projected sensitivity for m{sub ve} is 200 meV/c{sup 2} at 90% C.L. In order to map out the electric and magnetic fields in the main spectrometer, an angular selective electron gun is currently being developed. The e-gun uses an UV-Laser to produce electrons via the photo-electric effect from a copper substrate which are then accelerated electrostatically. It features a small energy spread of approx. 0.1 eV, a sharp emission angle and will be able to cover the whole magnetic flux tube of KATRIN. Using a pulsed laser it is also possible to investigate the time of flight (TOF) of electrons through the spectrometer, offering enhanced sensitivity to spectrometer properties far away from the analysing plane. By comparing information from transmission function measurements and TOF data with Monte Carlo simulations of the setup, one will be able to achieve a detailed understanding of the spectrometer properties.

  16. Development of an electron momentum spectrometer for time-resolved experiments employing nanosecond pulsed electron beam

    Science.gov (United States)

    Tang, Yaguo; Shan, Xu; Liu, Zhaohui; Niu, Shanshan; Wang, Enliang; Chen, Xiangjun

    2018-03-01

    The low count rate of (e, 2e) electron momentum spectroscopy (EMS) has long been a major limitation of its application to the investigation of molecular dynamics. Here we report a new EMS apparatus developed for time-resolved experiments in the nanosecond time scale, in which a double toroidal energy analyzer is utilized to improve the sensitivity of the spectrometer and a nanosecond pulsed electron gun with a repetition rate of 10 kHz is used to obtain an average beam current up to nA. Meanwhile, a picosecond ultraviolet laser with a repetition rate of 5 kHz is introduced to pump the sample target. The time zero is determined by photoionizing the target using a pump laser and monitoring the change of the electron beam current with time delay between the laser pulse and electron pulse, which is influenced by the plasma induced by the photoionization. The performance of the spectrometer is demonstrated by the EMS measurement on argon using a pulsed electron beam, illustrating the potential abilities of the apparatus for investigating the molecular dynamics in excited states when employing the pump-probe scheme.

  17. The use of vanadium as a scattering standard for pulsed source neutron spectrometers

    International Nuclear Information System (INIS)

    Mayers, J.

    1983-06-01

    The Gaussian approximation for multiphonon cross-sections has been used in a calculation of the variation of vanadium cross-sections with incident neutron energy. The results show that vanadium behaves as an elastic scatterer to within a few percent on pulsed neutron spectrometers with incident neutron energies up to 1 eV. There is a calculated anisotropy in the scattering of 8%. It is found that the scattering properties of vanadium at 77K and 293K differ by a maximum of 1% except for neutron energies < 15 meV. (author)

  18. spectrometer

    Directory of Open Access Journals (Sweden)

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  19. Investigation of the pulse shape analysis for the position sensitive γ-ray spectrometer AGATA

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Lars; Birkenbach, Benedikt; Reiter, Peter [Institut fuer Kernphysik Koeln (Germany); Collaboration: AGATA-Collaboration

    2015-07-01

    The next generation of γ-ray spectrometers like AGATA will provide high quality γ-ray spectra by the new Gamma-Ray Tracking technique (GRT). Position sensitive HPGe detectors will allow for precise Doppler correction and small broadening of lines for spectroscopy at relativistic energies. GRT is based on the interaction position of the γ-rays within the volume of the highly segmented germanium detectors provided by Pulse Shape Analysis (PSA) methods. The proof of principle of GRT was already demonstrated with great success however systematic deviations from expected results occur. The parameterization of the following detector properties and their impact on PSA were thoroughly investigated and optimized: electron and hole mobility, crystal axis orientation, space charge distributions, crystal impurities, response functions of preamplifiers and digitizers, linear and differential crosstalk, time alignment of pulses and the distance metric. Results of an improved PSA performance are presented.

  20. Pulsed single-photon spectrometer by frequency-to-time mapping using chirped fiber Bragg gratings.

    Science.gov (United States)

    Davis, Alex O C; Saulnier, Paul M; Karpiński, Michał; Smith, Brian J

    2017-05-29

    A fiber-integrated spectrometer for single-photon pulses outside the telecommunications wavelength range based upon frequency-to-time mapping, implemented by chromatic group delay dispersion (GDD), and precise temporally-resolved single-photon counting, is presented. A chirped fiber Bragg grating provides low-loss GDD, mapping the frequency distribution of an input pulse onto the temporal envelope of the output pulse. Time-resolved detection with fast single-photon-counting modules enables monitoring of a wavelength range from 825 nm to 835 nm with nearly uniform efficiency at 55 pm resolution (24 GHz at 830 nm). To demonstrate the versatility of this technique, spectral interference of heralded single photons and the joint spectral intensity distribution of a photon-pair source are measured. This approach to single-photon-level spectral measurements provides a route to realize applications of time-frequency quantum optics at visible and near-infrared wavelengths, where multiple spectral channels must be simultaneously monitored.

  1. Electron spin dynamics of Ce.sup.3+./sup. ions in YAG crystals studied by pulse-EPR and pump-probe Faraday rotation

    Czech Academy of Sciences Publication Activity Database

    Azamat, Dmitry; Belykh, V.V.; Yakovlev, D.R.; Fobbe, F.; Feng, D.H.; Evers, E.; Jastrabík, Lubomír; Dejneka, Alexandr; Bayer, M.

    2017-01-01

    Roč. 96, č. 7 (2017), s. 1-10, č. článku 075160. ISSN 2469-9950 R&D Projects: GA MŠk LO1409; GA ČR GA16-22092S Institutional support: RVO:68378271 Keywords : electron spin dynamics * Ce 3+ ions * YAG crystals * pulse-EPR * Faraday rotation Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 3.836, year: 2016

  2. Time-of-flight small-angle scattering spectrometers on pulsed neutron sources

    International Nuclear Information System (INIS)

    Ostanevich, Yu.M.

    1987-01-01

    The operation principles, constructions, advantages and shortcomings of known time-of-flight small angle neutron scattering (TOF SANS) spectrometers built up with pulsed neutron sources are reviewed. The most important characteristics of TOF SANS apparatuses are rather a high luminosity and the possibility for the measurement in an extremely wide range of scattering vector at a single exposure. This is achieved by simultaneous employment of white beam, TOF technique for wave length-scan and the commonly known angle-scan. However, the electronic equipment, data-matching programs, and the measurement procedure, necessary for accurate normalization of experimental data and their transformation into absolute cross-section scale, they all become more complex, as compared with those for SANS apparatuses operating on steady-state neutron sources, where only angle-scan is used

  3. Using rapid scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude

    OpenAIRE

    Möser, J.; Lips, K.; Tseytlin, M.; Eaton, G.; Eaton, S.; Schnegg, A

    2017-01-01

    X band rapid scan EPR was implemented on a commercially available Bruker ELEXSYS E580 spectrometer. Room temperature rapid scan and continuous wave EPR spectra were recorded for amorphous silicon powder samples. By comparing the resulting signal intensities the feasibility of performing quantitative rapid scan EPR is demonstrated. For different hydrogenated amorphous silicon samples, rapid scan EPR results in signal to noise improvements by factors between 10 and 50. Rapid scan EPR is thus ca...

  4. A pulse programmable parahydrogen polarizer using a tunable electromagnet and dual channel NMR spectrometer

    Science.gov (United States)

    Coffey, Aaron M.; Shchepin, Roman V.; Feng, Bibo; Colon, Raul D.; Wilkens, Ken; Waddell, Kevin W.; Chekmenev, Eduard Y.

    2017-11-01

    Applications of parahydrogen induced polarization (PHIP) often warrant conversion of the chemically-synthesized singlet-state spin order into net heteronuclear magnetization. In order to obtain optimal yields from the overall hyperpolarization process, catalytic hydrogenation must be tightly synchronized to subsequent radiofrequency (RF) transformations of spin order. Commercial NMR consoles are designed to synchronize applied waves on multiple channels and consequently are well-suited as controllers for these types of hyperpolarization experiments that require tight coordination of RF and non-RF events. Described here is a PHIP instrument interfaced to a portable NMR console operating with a static field electromagnet in the milliTesla regime. In addition to providing comprehensive control over chemistry and RF events, this setup condenses the PHIP protocol into a pulse-program that in turn can be readily shared in the manner of traditional pulse sequences. In this device, a TTL multiplexer was constructed to convert spectrometer TTL outputs into 24 VDC signals. These signals then activated solenoid valves to control chemical shuttling and reactivity in PHIP experiments. Consolidating these steps in a pulse-programming environment speeded calibration and improved quality assurance by enabling the B0/B1 fields to be tuned based on the direct acquisition of thermally polarized and hyperpolarized NMR signals. Performance was tested on the parahydrogen addition product of 2-hydroxyethyl propionate-1-13C-d3, where the 13C polarization was estimated to be P13C = 20 ± 2.5% corresponding to 13C signal enhancement approximately 25 million-fold at 9.1 mT or approximately 77,000-fold 13C enhancement at 3 T with respect to thermally induced polarization at room temperature.

  5. A peripheral component interconnect express-based scalable and highly integrated pulsed spectrometer for solution state dynamic nuclear polarization

    Energy Technology Data Exchange (ETDEWEB)

    He, Yugui; Liu, Chaoyang, E-mail: chyliu@wipm.ac.cn [Wuhan National Laboratory for Optoelectronics, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074 (China); State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071 (China); Feng, Jiwen; Wang, Dong; Chen, Fang; Liu, Maili [State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071 (China); Zhang, Zhi; Wang, Chao [State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071 (China); University of Chinese Academy of Sciences, Beijing 100048 (China)

    2015-08-15

    High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with high data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately −170 for {sup 1}H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo {sup 1}H MRI at 0.35 T.

  6. A Ku band pulsed electron paramagnetic resonance spectrometer using an arbitrary waveform generator for quantum control experiments at millikelvin temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Yung Szen, E-mail: yungszen@utm.my [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka-shi, Osaka 560-8531 (Japan); Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor (Malaysia); Tabuchi, Yutaka [Research Center for Advanced Science and Technology (RCAST), The University of Tokyo, Meguro-ku, Tokyo 153-8904 (Japan); Negoro, Makoto; Kagawa, Akinori; Kitagawa, Masahiro, E-mail: kitagawa@ee.es.osaka-u.ac.jp [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka-shi, Osaka 560-8531 (Japan)

    2015-06-15

    We present a 17 GHz (Ku band) arbitrary waveform pulsed electron paramagnetic resonance spectrometer for experiments down to millikelvin temperatures. The spectrometer is located at room temperature, while the resonator is placed either in a room temperature magnet or inside a cryogen-free dilution refrigerator; the operating temperature range of the dilution unit is from ca. 10 mK to 8 K. This combination provides the opportunity to perform quantum control experiments on electron spins in the pure-state regime. At 0.6 T, spin echo experiments were carried out using γ-irradiated quartz glass from 1 K to 12.3 mK. With decreasing temperatures, we observed an increase in spin echo signal intensities due to increasing spin polarizations, in accordance with theoretical predictions. Through experimental data fitting, thermal spin polarization at 100 mK was estimated to be at least 99%, which was almost pure state. Next, to demonstrate the ability to create arbitrary waveform pulses, we generate a shaped pulse by superposing three Gaussian pulses of different frequencies. The resulting pulse was able to selectively and coherently excite three different spin packets simultaneously—a useful ability for analyzing multi-spin system and for controlling a multi-qubit quantum computer. By applying this pulse to the inhomogeneously broadened sample, we obtain three well-resolved excitations at 8 K, 1 K, and 14 mK.

  7. Consensus structures of the Mo(v) sites of sulfite-oxidizing enzymes derived from variable frequency pulsed EPR spectroscopy, isotopic labelling and DFT calculations.

    Science.gov (United States)

    Enemark, John H

    2017-10-10

    Sulfite-oxidizing enzymes from eukaryotes and prokaryotes have five-coordinate distorted square-pyramidal coordination about the molybdenum atom. The paramagnetic Mo(v) state is easily generated, and over the years four distinct CW EPR spectra have been identified, depending upon enzyme source and the reaction conditions, namely high and low pH (hpH and lpH), phosphate inhibited (P i ) and sulfite (or blocked). Extensive studies of these paramagnetic forms of sulfite-oxidizing enzymes using variable frequency pulsed electron spin echo (ESE) spectroscopy, isotopic labeling and density functional theory (DFT) calculations have led to the consensus structures that are described here. Errors in some of the previously proposed structures are corrected.

  8. Development of a positive column pulsed capillary discharge source for use with high resolution Fourier transform spectrometer

    International Nuclear Information System (INIS)

    Syed, W A A

    2002-01-01

    We report the designing and application of a positive column pulsed capillary discharge with the Fourier transform spectrometer (FTS). The pulsed light source has been used for the first time with the ultraviolet FTS. The experiment has been carried out with the high energy pulsed discharge with energy of 2-3 J lasting about 300 ns. A system has been developed to trigger the discharge at about 600 Hz with the pulses directly taken from the FTS sampling system. The spectrum of Ar III has been recorded in the 19 000-50 000 cm -1 region with good signal to noise ratio. The results have opened a wide range of applications in spectroscopy of multiply ionized species

  9. The structural flexibility of the human copper chaperone Atox1: Insights from combined pulsed EPR studies and computations.

    Science.gov (United States)

    Levy, Ariel R; Turgeman, Meital; Gevorkyan-Aiapetov, Lada; Ruthstein, Sharon

    2017-08-01

    Metallochaperones are responsible for shuttling metal ions to target proteins. Thus, a metallochaperone's structure must be sufficiently flexible both to hold onto its ion while traversing the cytoplasm and to transfer the ion to or from a partner protein. Here, we sought to shed light on the structure of Atox1, a metallochaperone involved in the human copper regulation system. Atox1 shuttles copper ions from the main copper transporter, Ctr1, to the ATP7b transporter in the Golgi apparatus. Conventional biophysical tools such as X-ray or NMR cannot always target the various conformational states of metallochaperones, owing to a requirement for crystallography or low sensitivity and resolution. Electron paramagnetic resonance (EPR) spectroscopy has recently emerged as a powerful tool for resolving biological reactions and mechanisms in solution. When coupled with computational methods, EPR with site-directed spin labeling and nanoscale distance measurements can provide structural information on a protein or protein complex in solution. We use these methods to show that Atox1 can accommodate at least four different conformations in the apo state (unbound to copper), and two different conformations in the holo state (bound to copper). We also demonstrate that the structure of Atox1 in the holo form is more compact than in the apo form. Our data provide insight regarding the structural mechanisms through which Atox1 can fulfill its dual role of copper binding and transfer. © 2017 The Protein Society.

  10. The EPR reactor

    International Nuclear Information System (INIS)

    Lacoste, A.C.; Dupuy, Ph.; Gupta, O.; Perez, J.R.; Emond, D.; Cererino, G.; Rousseau, J.M.; Jeffroy, F.; Evrard, J.M.; Seiler, J.M.; Azarian, G.; Chaumont, B.; Dubail, A.; Fischer, M.; Tiippana, P.; Hyvarinen, J.; Zaleski, C.P.; Meritet, S.; Iglesias, F.; Vincent, C.; Massart, S.; Graillat, G.; Esteve, B.; Mansillon, Y.; Gatinol, C.; Carre, F.

    2005-01-01

    This document reviews economical and environmental aspects of the EPR project. The following topics are discussed: role and point of view of the French Nuclear Safety Authority on EPR, control of design and manufacturing of EPR by the French Nuclear Safety Authority, assessment by IRSN of EPR safety, research and development in support of EPR, STUK safety review of EPR design, standpoint on EPR, the place of EPR in the French energy policy, the place of EPR in EDF strategy, EPR spearhead of nuclear rebirth, the public debate, the local stakes concerning the building of EPR in France at Flamanville (Manche) and the research on fourth generation reactors. (A.L.B.)

  11. A multi-analyzer crystal spectrometer (MAX) for pulsed neutron sources

    International Nuclear Information System (INIS)

    Tajima, K.; Ishikawa, Y.; Kanai, K.; Windsor, C.G.; Tomiyoshi, S.

    1982-03-01

    The paper describes the principle and initial performance of a multi-analyzer crystal spectrometer (MAX) recently installed at the KENS spallation neutron source at Tsukuba. The spectrometer is able to make time of flight scans along a desired direction in reciprocal space, covering a wide range of the energy transfers corresponding to the fifteen analyzer crystals. The constant Q or constant E modes of operation can be performed. The spectrometer is particularly suited for studying collective excitations such as phonons and magnons to high energy transfers using single crystal samples. (author)

  12. Application of MSS-neutron spin echo spectrometer to pulsed neutron sources

    International Nuclear Information System (INIS)

    Tasaki, S.; Ebisawa, T.; Hino, M.; Kawai, T.

    2001-01-01

    A multilayer spin splitter (MSS) is a neutron device that gives phase difference between field-parallel and -antiparallel spin component of a superposing state. Since the phase difference is equivalent to the Larmor precession angle, MSS enables us to construct a new type of neutron spin echo (NSE) spectrometer. The new NSE spectrometer has its properties that 1. since the phase shift is neutron flight path length, the spectrometer can be drastically small, 2. the neutron spin echo time is proportional to the neutron wavelength. (author)

  13. Fan analyzer of neutron beam polarization on REMUR spectrometer at IBR-2 pulsed reactor

    International Nuclear Information System (INIS)

    Nikitenko, Yu.V.; Ul'yanov, V.A.; Pusenkov, V.M.; Kozhevnikov, S.V.; Jernenkov, K.N.; Pleshanov, N.K.; Peskov, B.G.; Petrenko, A.V.; Proglyado, V.V.; Syromyatnikov, V.G.; Schebetov, A.F.

    2006-01-01

    The new spectrometer of polarized neutrons REMUR has been created and put in operation in the Frank Laboratory of Neutron Physics (JINR, Dubna). The spectrometer is dedicated to investigations of multiplayer structures and surfaces by registering the reflection of polarized neutrons and of the inhomogeneous state of solid matter by measuring the small-angle scattering of polarized neutrons. The spectrometer's working range of neutron wavelengths is 1.5-10 A. The spectrometer is equipped with a linear position-sensitive detector and a focused supermirror polarization analyzer (fan-like polarization analyzer) with a solid angle of neutron detection of 2.2x10 -4 rad. This article describes the design and the principle of operation of the fan analyzer of neutron polarization together with the results of its tests on a polarized neutron beam

  14. Simulation for developing new pulse neutron spectrometers I. Creation of new McStas components of moderators of JSNS

    CERN Document Server

    Tamura, I; Arai, M; Harada, M; Maekawa, F; Shibata, K; Soyama, K

    2003-01-01

    Moderators components of the McStas code have been created for the design of JSNS instruments. Three cryogenic moderators are adopted in JSNS, one is coupled H sub 2 moderators for high intensity experiments and other two are decoupled H sub 2 with poisoned or unpoisoned for high resolution moderators. Since the characteristics of neutron beams generated from moderators make influence on the performance of pulse neutron spectrometers, it is important to perform the Monte Carlo simulation with neutron source component written precisely. The neutron spectrum and time structure were calculated using NMTC/JAERI97 and MCNP4a codes. The simulation parameters, which describe the pulse shape over entire spectrum as a function of time, are optimized. In this paper, the creation of neutron source components for port No.16 viewed to coupled H sub 2 moderator and for port No.11 viewed to decoupled H sub 2 moderator of JSNS are reported.

  15. EPR spectroscopy of spices

    Directory of Open Access Journals (Sweden)

    R. T. Тimakova

    2016-01-01

    Full Text Available From 01 January 2017 you enter the interstate standard GOST 33271-2015 “Dry Spices, herbs and vegetable seasonings. Manual exposure in order to combat pathogens and other microorganisms” which States that the absorbed dose of radiation to the spices should be from 3 to 30 kGy. The study found that before the introduction of permissive legislative framework in the consumer market of Russia there are irradiated food products (chili, ground chili, ground spicy chili, black pepper. For radiation monitoring of food safety, we used the method of electron paramagnetic resonance (EPR, which allows quickly and with a high degree of reliability to establish the fact of irradiation. It is established that all samples of spices irradiated with dose of 12 kGy (technology radappertization gave typical spectra of the signals established by the method of electron paramagnetic resonance in the domestic EPR spectrometer, the intensity, amplitude and peak width of the EPR signal of samples of spices with the increase of irradiation dose increases. It is proven that repeated exposure no effect accumulation. Integration with 2017 Russia in the global practi ce of using radiation technologies of processing of food products and food raw materials with the purpose of extending shelf life confirms the need for a data Bank on the radiation sensitivity of various food products to determine the optimal doses and the eff ect of radiation doses on the shelf life and quality of products.

  16. The polarized neutron spectrometer REMUR at the pulsed reactor IBR-2

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Zhernenkov, K.N.; Kozhevnikov, S.V.; Nikitenko, Yu.V.; Petrenko, A.V.; Lauter, H.J.; Lauter-Pasyuk, V.

    2004-01-01

    At the Laboratory of Neutron Physics (JINR, Dubna) the new polarized neutron spectrometer REMUR has been constructed and commissioned. The spectrometer REMUR is dedicated to investigations of multilayers and surfaces by polarized neutron reflection and of the inhomogeneous state of solids by diffuse small-angle polarized neutron scattering. The spectrometer operates in the neutron wavelength interval 1-10 Angstroem. In the reflectometry mode it allows one to complete polarization analysis and neutron position-sensitive detection within the solid angle of scattering 2.2·10 -4 rad. The spectrometer ensures good statistics of the reflectometric data in the scattering wave vector interval 3·10 -3 - 5·10 -1 Angstroem -1 . In the small-angle scattering mode the spectrometer allows the investigation of neutron scattering processes without spin-flip over the detector's neutron registration solid angle interval from 4·10 -3 to 10 -1 rad and the scattering wave vector interval from 0.006-0.15 to 0.03-0.7 Angstroem -1 , respectively

  17. Improving detector signal processing with pulse height analysis in Moessbauer spectrometers

    International Nuclear Information System (INIS)

    Pechousek, Jiri; Mashlan, Miroslav; Frydrych, Jiri; Jancik, Dalibor; Prochazka, Roman

    2007-01-01

    A plenty of different programming techniques and instrument solutions are used in the development of Moessbauer spectrometers. Each of them should provide a faster spectrum accumulation process, increased productivity of measurements, decreased nonlinearity of the velocity scale, etc. The well known virtual instrumentation programming method has been used to design a computer-based Moessbauer spectrometer. Hardware solution was based on two commercially-available PCI modules produced by National Instruments Co. Virtual Moessbauer spectrometer is implemented by the graphical programming language LabVIEW 7 Express. This design environment allows to emulate the multichannel analyzer on the digital oscilloscope platform. This is a novel method based on Waveform Peak Detection function which allows detailed analysis of the acquired signal. The optimal treatment of the detector signal from various detector types is achieved by mathematical processing only. As a result, the possibility of an increase of signal/noise ratio is presented.

  18. Polarisation analysis of elastic neutron scattering using a filter spectrometer on a pulsed source

    International Nuclear Information System (INIS)

    Mayers, J.; Williams, W.G.

    1981-05-01

    The experimental and theoretical aspects of the polarisation analysis technique in elastic neutron scattering are described. An outline design is presented for a filter polarisation analysis spectrometer on the Rutherford Laboratory Spallation Neutron Source and estimates made of its expected count rates and resolution. (author)

  19. The performance of neutron spectrometers AR a long-pulse spallation source

    International Nuclear Information System (INIS)

    Pynn, R.; Daemen, L.L.

    1995-01-01

    At a recent workshop at Lawrence Berkeley National Laboratory members of the international neutron scattering community discussed the performance to be anticipated from neutron scattering instruments installed at a 1 MW long-pulse spallation source (LPSS). Although the report of this workshop is long, its principal conclusions can be easily summarised and almost as easily understood. This article presents such a synthesis for a 60 Hz LPSS with 1 msec proton pulses. We discuss some of the limitations of the workshop conclusions and suggest a simple analysis of the performance differences that might be expected between short- and long-pulse sources both of which exploit coupled moderators

  20. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  1. Lesion-induced DNA weak structural changes detected by pulsed EPR spectroscopy combined with site-directed spin labelling.

    Science.gov (United States)

    Sicoli, Giuseppe; Mathis, Gérald; Aci-Sèche, Samia; Saint-Pierre, Christine; Boulard, Yves; Gasparutto, Didier; Gambarelli, Serge

    2009-06-01

    Double electron-electron resonance (DEER) was applied to determine nanometre spin-spin distances on DNA duplexes that contain selected structural alterations. The present approach to evaluate the structural features of DNA damages is thus related to the interspin distance changes, as well as to the flexibility of the overall structure deduced from the distance distribution. A set of site-directed nitroxide-labelled double-stranded DNA fragments containing defined lesions, namely an 8-oxoguanine, an abasic site or abasic site analogues, a nick, a gap and a bulge structure were prepared and then analysed by the DEER spectroscopic technique. New insights into the application of 4-pulse DEER sequence are also provided, in particular with respect to the spin probes' positions and the rigidity of selected systems. The lesion-induced conformational changes observed, which were supported by molecular dynamics studies, confirm the results obtained by other, more conventional, spectroscopic techniques. Thus, the experimental approaches described herein provide an efficient method for probing lesion-induced structural changes of nucleic acids.

  2. PRISMA - a spectrometer for the measurement of coherent excitations on a pulsed spallation neutron source

    International Nuclear Information System (INIS)

    Andreani, C.; Cilloco, F.; Petrillo, C.; Sacchetti, F.; Windsor, C.G.

    1986-04-01

    The measurement of nuclear and magnetic excitation spectra from single crystal samples remains central to condensed matter physics. The requirements in terms of the range and resolution of the scattering vector Q and energy transfer h/2πω are reviewed and typical experiments with a well defined cross-section are chosen. The performance and limitations of existing instruments are reviewed. A design for a new spectrometer, PRISMA, to be installed on the UK spallation neutron source, ISIS, is presented. Its performance for chosen experiments is given in terms of the Q and h/2πω range covered in a single scan, the resolution and the count rate. (author)

  3. EPR and NMR detection of transient radicals and reaction products

    International Nuclear Information System (INIS)

    Trifunac, A.D.

    1981-01-01

    Magnetic resonance methods in radiation chemistry are illustrated. The most recent developments in pulsed EPR and NMR studies in pulse radiolysis are outlined with emphasis on the study of transient radicals and their reaction products. 12 figures

  4. Neutron scattering studies of the dynamics of biopolymer-water systems using pulsed-source spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Middendorf, H.D. [Univ. of Oxford (United Kingdom); Miller, A. [Stirling Univ., Stirling (United Kingdom)

    1994-12-31

    Energy-resolving neutron scattering techniques provide spatiotemporal data suitable for testing and refining analytical models or computer simulations of a variety of dynamical processes in biomolecular systems. This paper reviews experimental work on hydrated biopolymers at ISIS, the UK Pulsed Neutron Facility. Following an outline of basic concepts and a summary of the new instrumental capabilities, the progress made is illustrated by results from recent experiments in two areas: quasi- elastic scattering from highly hydrated polysaccharide gels (agarose and hyaluronate), and inelastic scattering from vibrational modes of slightly hydrated collagen fibers.

  5. Neutron scattering studies of the dynamics of biopolymer-water systems using pulsed-source spectrometers

    International Nuclear Information System (INIS)

    Middendorf, H.D.; Miller, A.

    1994-01-01

    Energy-resolving neutron scattering techniques provide spatiotemporal data suitable for testing and refining analytical models or computer simulations of a variety of dynamical processes in biomolecular systems. This paper reviews experimental work on hydrated biopolymers at ISIS, the UK Pulsed Neutron Facility. Following an outline of basic concepts and a summary of the new instrumental capabilities, the progress made is illustrated by results from recent experiments in two areas: quasi- elastic scattering from highly hydrated polysaccharide gels (agarose and hyaluronate), and inelastic scattering from vibrational modes of slightly hydrated collagen fibers

  6. Nitrogen ligation to manganese in the photosynthetic oxygen-evolving complex: Continuous-wave and pulsed EPR studies of Photosystem II particles containing 14N or 15N

    International Nuclear Information System (INIS)

    DeRose, V.J.; Yachandra, V.K.; McDermott, A.E.; Britt, R.D.; Sauer, K.; Klein, M.P.

    1991-01-01

    The possibility of nitrogen ligation to the Mn in the oxygen-evolving complex from photosystem II was investigated with electron paramagnetic resonance (EPR) and electron spin echo envelope modulation (ESEEM) spectroscopies using 14 N- and 15 N-labeled preparations. Oxygen-evolving preparations were isolated from a thermophilic cyanobacterium, Synechococcus sp., grown on a medium containing either 14 NO 3 - or 15 NO - 3 as the sole source of nitrogen. The substructure on the multiline EPR signal, which arises from Mn in the S 2 state of the enzyme, was measured with continuous-wave EPR. No changes were detected in the substructure peak positions upon substitution of 15 N for 14 N, indicating that this substructure is not due to superhyperfine coupling from nitrogen ligands. To detect potential nitrogen ligands with superhyperfine couplings of lesser magnitude than could be observed with conventional EPR methods, electron spin-echo envelope modulation experiments were also performed on the multiline EPR signal. The Fourier transform of the light-minus-dark time domain ESEEM data shows a peak at 4.8 MHz in 14 N samples which is absent upon substitution with 15 N. This gives unambiguous evidence for weak hyperfine coupling of nitrogen to the Mn of the oxygen-evolving complex. Possible origins of this nitrogen interaction are discussed

  7. Comparison of continuous wave, spin echo, and rapid scan EPR of irradiated fused quartz

    International Nuclear Information System (INIS)

    Mitchell, Deborah G.; Quine, Richard W.; Tseitlin, Mark; Meyer, Virginia; Eaton, Sandra S.; Eaton, Gareth R.

    2011-01-01

    The E' defect in irradiated fused quartz has spin lattice relaxation times (T 1 ) about 100-300 μs and spin-spin relaxation times (T 2 ) up to about 200 μs, depending on the concentration of defects and other species in the sample. These long relaxation times make it difficult to record an unsaturated continuous wave (CW) electron paramagnetic resonance (EPR) signal that is free of passage effects. Signals measured at X-band (∼9.5 GHz) by three EPR methods: conventional slow-scan field-modulated EPR, rapid scan EPR, and pulsed EPR, were compared. To acquire spectra with comparable signal-to-noise, both pulsed and rapid scan EPR require less time than conventional CW EPR. Rapid scan spectroscopy does not require the high power amplifiers that are needed for pulsed EPR. The pulsed spectra, and rapid scan spectra obtained by deconvolution of the experimental data, are free of passage effects.

  8. EPR and Bell Locality

    OpenAIRE

    Norsen, Travis

    2004-01-01

    A new formulation of the EPR argument is presented, one which uses John Bell's mathematically precise local causality condition in place of the looser locality assumption which was used in the original EPR paper and on which Niels Bohr seems to have based his objection to the EPR argument. The new formulation of EPR bears a striking resemblance to Bell's derivation of his famous inequalities. The relation between these two arguments -- in particular, the role of EPR as part one of Bell's two-...

  9. EPR-dosimetry of ionizing radiation

    Science.gov (United States)

    Popova, Mariia; Vakhnin, Dmitrii; Tyshchenko, Igor

    2017-09-01

    This article discusses the problems that arise during the radiation sterilization of medical products. It is propose the solution based on alanine EPR-dosimetry. The parameters of spectrometer and methods of absorbed dose calculation are given. In addition, the problems that arise during heavy particles irradiation are investigated.

  10. Measurement of the pulse pileup correction for the HPGe gamma spectrometer

    International Nuclear Information System (INIS)

    Kulkarni, D.B.; Anuradha, R.; Joseph, Leena; Kulkarni, M.S.

    2018-01-01

    Radiation Standards Section (RSS), RSSD, has HPGe gamma spectrometry system maintained as a secondary standard for standardization of gamma emitting radionuclides. This system is also used to detect the impurities in the radioactivity samples supplied for the international inter-comparison exercises, so that the appropriate correction can be made for the standardized activity of principle radionuclide. The system is calibrated as per the recommended procedure (ANSI standard N42.14, 1999). As a part of this calibration, measurement of the pulse pile up correction was carried out in the energy range of 81 keV to 1408 keV. The measurement of pileup correction is very important for the standardization of sources having higher counting rates where the extent of the pileup effect is more and considerable deviation from the true counting rates was observed. For these sources the measured photo peak counting rate is less than true counting rate and needs to be corrected for pileup effect. The details of experiments are discussed in this paper

  11. Study and fabrication of a broadband receiver with frequency change for a spectrometer by Nuclear Magnetic Resonance based on pulse in liquids

    International Nuclear Information System (INIS)

    Avril, Robert

    1974-01-01

    The objective of this work has been, by using the pulsed NMR technique, to study and produce a set for the reception of the nuclear precession signal for a broadband (1-60 MHz) spectrometer. In a first part, the author recalls some fundamental elements of pulsed NMR, and discusses the assessment of the precession signal amplitude which can be expected. Then, he gives a detailed description of the various components of the reception chain (modulator, amplifiers, broadband pre-amplifiers, diode gate, frequency changer, synchronous detection), and, through experimentation and measurements, outlines the ease of implementation and adaptation to measurement conditions

  12. Broadband 2D electronic spectrometer using white light and pulse shaping: noise and signal evaluation at 1 and 100 kHz.

    Science.gov (United States)

    Kearns, Nicholas M; Mehlenbacher, Randy D; Jones, Andrew C; Zanni, Martin T

    2017-04-03

    We have developed a broad bandwidth two-dimensional electronic spectrometer that operates shot-to-shot at repetition rates up to 100 kHz using an acousto-optic pulse shaper. It is called a two-dimensional white-light (2D-WL) spectrometer because the input is white-light supercontinuum. Methods for 100 kHz data collection are studied to understand how laser noise is incorporated into 2D spectra during measurement. At 100 kHz, shot-to-shot scanning of the delays and phases of the pulses in the pulse sequence produces a 2D spectrum 13-times faster and with the same signal-to-noise as using mechanical stages and a chopper. Comparing 100 to 1 kHz repetition rates, data acquisition time is decreased by a factor of 200, which is beyond the improvement expected by the repetition rates alone due to reduction in 1/f noise. These improvements arise because shot-to-shot readout and modulation of the pulse train at 100 kHz enables the electronic coherences to be measured faster than the decay in correlation between laser intensities. Using white light supercontinuum for the pump and probe pulses produces high signal-to-noise spectra on samples with optical densities 200 nm bandwidth.

  13. Rapid high-resolution spin- and angle-resolved photoemission spectroscopy with pulsed laser source and time-of-flight spectrometer

    Science.gov (United States)

    Gotlieb, K.; Hussain, Z.; Bostwick, A.; Lanzara, A.; Jozwiak, C.

    2013-09-01

    A high-efficiency spin- and angle-resolved photoemission spectroscopy (spin-ARPES) spectrometer is coupled with a laboratory-based laser for rapid high-resolution measurements. The spectrometer combines time-of-flight (TOF) energy measurements with low-energy exchange scattering spin polarimetry for high detection efficiencies. Samples are irradiated with fourth harmonic photons generated from a cavity-dumped Ti:sapphire laser that provides high photon flux in a narrow bandwidth, with a pulse timing structure ideally matched to the needs of the TOF spectrometer. The overall efficiency of the combined system results in near-EF spin-resolved ARPES measurements with an unprecedented combination of energy resolution and acquisition speed. This allows high-resolution spin measurements with a large number of data points spanning multiple dimensions of interest (energy, momentum, photon polarization, etc.) and thus enables experiments not otherwise possible. The system is demonstrated with spin-resolved energy and momentum mapping of the L-gap Au(111) surface states, a prototypical Rashba system. The successful integration of the spectrometer with the pulsed laser system demonstrates its potential for simultaneous spin- and time-resolved ARPES with pump-probe based measurements.

  14. Selfcalibrated alanine/EPR dosimeters. A new generation of solid state/EPR dosimeters

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Gancheva, V.

    1999-01-01

    Alanine/EPR dosimeters are well established as secondary, reference dosimeters for high-energy radiation. However, there are various sources of uncertainty in the evaluation of absorbed dose. This arises primarily from the necessity to calibrate each EPR spectrometer and each batch of dosimeters before their use. In order to overcome this disadvantage, a new generation alanine/EPR dosimeter has been developed, and its possibilities as a radiation detector are reported. Principally, it is a mixture of alanine, some quantity of EPR active substance, and a binding material. The EPR active substance, acting as an internal EPR standard, is chosen to have EPR parameters which are independent of the irradiation dose. The simultaneous recording of the spectra of both the sample and the standard under the same experimental conditions and the estimation of the ratio I alanine /I Mn as a function of the absorbed dose strongly reduces the uncertainties. The response of these dosimeters for 60 Co γ-radiation exhibits excellent linearity and reproducibility in the range of absorbed dose, 10 2 - 5 x 10 4 Gy. (author)

  15. Stability of cellulose radicals produced by radiation in spices as studied by the EPR spectroscopy

    International Nuclear Information System (INIS)

    Lehner, K.; Stachowicz, W.

    2003-01-01

    The results are presented of EPR measurements on the stability of cellulose radicals produced in 26 popular spices irradiated with a dose of 7 kGy of gamma rays. EPR measurements were done with the use of an EPR spectrometer EPR-10 MINI at X band (microwave radiation of frequency 9.5 GHz), produced by St. Petersburg Instruments Ltd. The aim of the work was to prove the applicability of the EPR method for the control of irradiation in the investigated spices. (author)

  16. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet.

    Science.gov (United States)

    Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao

    2017-08-01

    A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.

  17. Limits in EPR dosimetry for irradiated dried fruits discrimination

    International Nuclear Information System (INIS)

    Brasoveanu, Mirela M. E-mirela@alpha.infim.ro; Nemtanu, R.; Minea, R.; Grecu, V.V.

    2003-01-01

    Irradiation of food induces free radical species. EPR dosimetry in irradiated goods puts in evidence if these radicals are stable in environmental condition. Irradiation of dried fruits has been carried out. Their behaviour under irradiation was investigated and correlation between EPR signal and irradiation dose was determined. Electrons of 6 MeV (mean energy) and doses up to 10 kGy were used. EPR spectra were recorded with a Jeol spectrometer, JES-ME-3X tip, with a 100 kHz modulation. The dried fruits can be separated into categories depending on the EPR signal intensity. Strong signals are observed in those fruits in which possible crystalline-like phases exist. As the amount of crystallized sugar decreases, the EPR signals become weaker. Dependencies on irradiation dose give a linear correlation below 10 kGy. The spectra are compared to irradiated sugar and differences and similarities are discussed. (authors)

  18. A fan analyzer of neutron beam polarization on the spectrometer REMUR at the pulsed reactor IBR-2

    International Nuclear Information System (INIS)

    Ul'yanov, V.A.; Pusenkov, V.M.; Pleshanov, N.K.

    2004-01-01

    The new spectrometer of polarized neutrons REMUR has been created and put in operation at the Frank Laboratory of Neutron Physics (JINR, Dubna). The spectrometer is dedicated to investigations of multilayer structures and surfaces by registering the reflection of polarized neutrons and of the inhomogeneous state of solid matter by measuring the small-angle scattering of polarized neutrons. The spectrometer's working range of neutron wavelengths is 1.5-10 Angstroem. The spectrometer is equipped with a linear position-sensitive detector and a focused supermirror polarization analyzer (the fan-like polarization analyzer) with a solid angle of polarized neutron detection of 2.2·10 -4 rad. This paper describes the design and the principle of operation of the fan analyzer of neutron polarization together with the results of the fan tests on a polarized neutron beam

  19. Optimal registration conditions for tooth EPR dosimetry at low accumulated dose

    International Nuclear Information System (INIS)

    Galtsev, V.E.; Galtseva, E.V.; Lebedev, Y.S.

    1997-01-01

    The spectrum registration under rapid passage conditions (the second harmonic phase quadrature of the absorption signal) allows one to enhance substantially the sensitivity of tooth enamel and bone EPR dosimetry at a low accumulated dose. In the present work the dependencies of the radiation and background signals on EPR spectrometer parameters are described and the optimal conditions in RPM for EPR dosimetry are obtained. (Author)

  20. Measurements of ion temperature and flow of pulsed plasmas produced by a magnetized coaxial plasma gun device using an ion Doppler spectrometer

    Science.gov (United States)

    Kitagawa, Y.; Sakuma, I.; Iwamoto, D.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    It is important to know surface damage characteristics of plasma-facing component materials during transient heat and particle loads such as type I ELMs. A magnetized coaxial plasma gun (MCPG) device has been used as transient heat and particle source in ELM simulation experiments. Characteristics of pulsed plasmas produced by the MCPG device play an important role for the plasma material interaction. In this study, ion temperature and flow velocity of pulsed He plasmas were measured by an ion Doppler spectrometer (IDS). The IDS system consists of a light collection system including optical fibers, 1m-spectrometer and a 16 channel photomultiplier tube (PMT) detector. The IDS system measures the width and Doppler shift of HeII (468.58 nm) emission line with the time resolution of 1 μs. The Doppler broadened and shifted spectra were measured with 45 and 135 degree angles with respect to the plasmoid traveling direction. The observed emission line profile was represented by sum of two Gaussian components to determine the temperature and flow velocity. The minor component at around the wavelength of zero-velocity was produced by the stationary plasma. As the results, the ion velocity and temperature were 68 km/s and 19 eV, respectively. Thus, the He ion flow energy is 97 eV. The observed flow velocity agrees with that measured by a time of flight technique.

  1. Medical application of EPR

    International Nuclear Information System (INIS)

    Eichhoff, Uwe; Hoefer, Peter

    2015-01-01

    Selected applications of continuous-wave EPR in medicine are reviewed. This includes detection of reactive oxygen and nitrogen species, pH measurements and oxymetry. Applications of EPR imaging are demonstrated on selected examples and future developments to faster imaging methods are discussed

  2. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  3. Mechanical neutron spectrometer Chopper - Start-up pulse and its generation; Neutronski mehanicki spektrometar (coper) - Startni impuls i njegova realizacija

    Energy Technology Data Exchange (ETDEWEB)

    Maglic, R [Institute of Nuclear Sciences Boris Kidric, Laboratorija za reaktorsku i neutronsku fiziku, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    This annex discusses the theoretical approach to generating the start-up pulse and describes the electric circuit which was designed for its generation. For achieving the needed precision calibration had to be done.

  4. One-way EPR steering and genuine multipartite EPR steering

    Science.gov (United States)

    He, Qiongyi; Reid, Margaret D.

    2012-11-01

    We propose criteria and experimental strategies to realise the Einstein-Podolsky-Rosen (EPR) steering nonlocality. One-way steering can be obtained where there is asymmetry of thermal noise on each system. We also present EPR steering inequalities that act as signatures and suggest how to optimise EPR correlations in specific schemes so that the genuine multipartite EPR steering nonlocality (EPR paradox) can also possibly be realised. The results presented here also apply to the spatially separated macroscopic atomic ensembles.

  5. EPR: Evidence and fallacy.

    Science.gov (United States)

    Nichols, Joseph W; Bae, You Han

    2014-09-28

    The enhanced permeability and retention (EPR) of nanoparticles in tumors has long stood as one of the fundamental principles of cancer drug delivery, holding the promise of safe, simple and effective therapy. By allowing particles preferential access to tumors by virtue of size and longevity in circulation, EPR provided a neat rationale for the trend toward nano-sized drug carriers. Following the discovery of the phenomenon by Maeda in the mid-1980s, this rationale appeared to be well justified by the flood of evidence from preclinical studies and by the clinical success of Doxil. Clinical outcomes from nano-sized drug delivery systems, however, have indicated that EPR is not as reliable as previously thought. Drug carriers generally fail to provide superior efficacy to free drug systems when tested in clinical trials. A closer look reveals that EPR-dependent drug delivery is complicated by high tumor interstitial fluid pressure (IFP), irregular vascular distribution, and poor blood flow inside tumors. Furthermore, the animal tumor models used to study EPR differ from clinical tumors in several key aspects that seem to make EPR more pronounced than in human patients. On the basis of this evidence, we believe that EPR should only be invoked on a case-by-case basis, when clinical evidence suggests the tumor type is susceptible. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. X-band EPR setup with THz light excitation of Novosibirsk Free Electron Laser: Goals, means, useful extras

    Science.gov (United States)

    Veber, Sergey L.; Tumanov, Sergey V.; Fursova, Elena Yu.; Shevchenko, Oleg A.; Getmanov, Yaroslav V.; Scheglov, Mikhail A.; Kubarev, Vitaly V.; Shevchenko, Daria A.; Gorbachev, Iaroslav I.; Salikova, Tatiana V.; Kulipanov, Gennady N.; Ovcharenko, Victor I.; Fedin, Matvey V.

    2018-03-01

    Electron Paramagnetic Resonance (EPR) station at the Novosibirsk Free Electron Laser (NovoFEL) user facility is described. It is based on X-band (∼9 GHz) EPR spectrometer and operates in both Continuous Wave (CW) and Time-Resolved (TR) modes, each allowing detection of either direct or indirect influence of high-power NovoFEL light (THz and mid-IR) on the spin system under study. The optics components including two parabolic mirrors, shutters, optical chopper and multimodal waveguide allow the light of NovoFEL to be directly fed into the EPR resonator. Characteristics of the NovoFEL radiation, the transmission and polarization-retaining properties of the waveguide used in EPR experiments are presented. The types of proposed experiments accessible using this setup are sketched. In most practical cases the high-power radiation applied to the sample induces its rapid temperature increase (T-jump), which is best visible in TR mode. Although such influence is a by-product of THz radiation, this thermal effect is controllable and can deliberately be used to induce and measure transient signals of arbitrary samples. The advantage of tunable THz radiation is the absence of photo-induced processes in the sample and its high penetration ability, allowing fast heating of a large portion of virtually any sample and inducing intense transients. Such T-jump TR EPR spectroscopy with THz pulses has been previewed for the two test samples, being a useful supplement for the main goals of the created setup.

  7. X-band EPR setup with THz light excitation of Novosibirsk Free Electron Laser: Goals, means, useful extras.

    Science.gov (United States)

    Veber, Sergey L; Tumanov, Sergey V; Fursova, Elena Yu; Shevchenko, Oleg A; Getmanov, Yaroslav V; Scheglov, Mikhail A; Kubarev, Vitaly V; Shevchenko, Daria A; Gorbachev, Iaroslav I; Salikova, Tatiana V; Kulipanov, Gennady N; Ovcharenko, Victor I; Fedin, Matvey V

    2018-03-01

    Electron Paramagnetic Resonance (EPR) station at the Novosibirsk Free Electron Laser (NovoFEL) user facility is described. It is based on X-band (∼9 GHz) EPR spectrometer and operates in both Continuous Wave (CW) and Time-Resolved (TR) modes, each allowing detection of either direct or indirect influence of high-power NovoFEL light (THz and mid-IR) on the spin system under study. The optics components including two parabolic mirrors, shutters, optical chopper and multimodal waveguide allow the light of NovoFEL to be directly fed into the EPR resonator. Characteristics of the NovoFEL radiation, the transmission and polarization-retaining properties of the waveguide used in EPR experiments are presented. The types of proposed experiments accessible using this setup are sketched. In most practical cases the high-power radiation applied to the sample induces its rapid temperature increase (T-jump), which is best visible in TR mode. Although such influence is a by-product of THz radiation, this thermal effect is controllable and can deliberately be used to induce and measure transient signals of arbitrary samples. The advantage of tunable THz radiation is the absence of photo-induced processes in the sample and its high penetration ability, allowing fast heating of a large portion of virtually any sample and inducing intense transients. Such T-jump TR EPR spectroscopy with THz pulses has been previewed for the two test samples, being a useful supplement for the main goals of the created setup. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. EPR of gamma irradiated solid sucrose and UV spectra of its solution. An attempt for calibration of solid state/EPR dosimetry

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Karakirova, Y.

    2007-01-01

    A simple new approach for independent calibration of solid state/EPR (SS/EPR) dosimetry system is reported. It is based on the fact that: (i) gamma-irradiation of solid sucrose (sugar) induces stable EPR detectable free radicals accompanied by UV detectable brown colour stable in the solid state and in solution; (ii) both the EPR intensity of gamma-irradiated solid sucrose and its solution UV absorbance linearly depend on the absorbed dose high energy radiation and may be independently used for dosimetric purpose; (iii) UV spectrometers are calibrated. The correlation between EPR response and absorbed dose radiation of solid sucrose and UV absorption of its solutions is used in the present communication for calibration purpose. The procedure of sucrose extraction from sucrose-paraffin dosimeters is described. The calibration procedure may be applied to any other (alanine, self-calibrated, etc.) SS/EPR dosimeters, simultaneously irradiated with sucrose

  9. Pulsed EPR study of low-dose irradiation effects in L-alanine crystals irradiated with γ-rays, Ne and Si ion beams

    International Nuclear Information System (INIS)

    Rakvin, B.; Maltar-Strmecki, N.; Nakagawa, K.

    2007-01-01

    Low-dose irradiation effects in L-alanine single crystals irradiated with γ-rays, Ne and Si ion beams have been investigated by means of a two-pulse electron spin echo (ESE) technique. An effective phase memory time, T M , was measured from the first stable L-alanine radical, SAR1, and its complex relaxation mechanism is discussed. Both spectral and instantaneous diffusion contributions to the total effective relaxation rate have been extrapolated through the detection of the two-pulse ESE signal as a function of turning angle. The local microscopic concentration of paramagnetic centers C(ions)/C(γ-ray) for low-dose heavy-ion irradiation has been deduced from the corresponding spin-spin interaction

  10. Clinical EPR: Unique Opportunities and Some Challenges

    Science.gov (United States)

    Swartz, Harold M.; Williams, Benjamin B.; Zaki, Bassem I.; Hartford, Alan C.; Jarvis, Lesley A.; Chen, Eunice; Comi, Richard J.; Ernstoff, Marc S.; Hou, Huagang; Khan, Nadeem; Swarts, Steven G.; Flood, Ann B.; Kuppusamy, Periannan

    2014-01-01

    Electron paramagnetic resonance (EPR) spectroscopy has been well established as a viable technique for measurement of free radicals and oxygen in biological systems, from in vitro cellular systems to in vivo small animal models of disease. However, the use of EPR in human subjects in the clinical setting, although attractive for a variety of important applications such as oxygen measurement, is challenged with several factors including the need for instrumentation customized for human subjects, probe and regulatory constraints. This paper describes the rationale and development of the first clinical EPR systems for two important clinical applications, namely, measurement of tissue oxygen (oximetry), and radiation dose (dosimetry) in humans. The clinical spectrometers operate at 1.2 GHz frequency and use surface loop resonators capable of providing topical measurements up to 1 cm depth in tissues. Tissue pO2 measurements can be carried out noninvasively and repeatedly after placement of an oxygen-sensitive paramagnetic material (currently India ink) at the site of interest. Our EPR dosimetry system is capable of measuring radiation-induced free radicals in the tooth of irradiated human subjects to determine the exposure dose. These developments offer potential opportunities for clinical dosimetry and oximetry, which include guiding therapy for individual patients with tumors or vascular disease, by monitoring of tissue oxygenation. Further work is in progress to translate this unique technology to routine clinical practice. PMID:24439333

  11. A sub-Kelvin cryogen-free EPR system.

    Science.gov (United States)

    Melhuish, Simon J; Stott, Chloe; Ariciu, Ana-Maria; Martinis, Lorenzo; McCulloch, Mark; Piccirillo, Lucio; Collison, David; Tuna, Floriana; Winpenny, Richard

    2017-09-01

    We present an EPR instrument built for operation at Q band below 1K. Our cryogen-free Dewar integrates with a commercial electro-magnet and bridge. A description of the cryogenic and RF systems is given, along with the adaptations to the standard EPR experiment for operation at sub-Kelvin temperatures. As a first experiment, the EPR spectra of powdered Cr 12 O 9 (OH) 3 [Formula: see text] were measured. The sub-Kelvin EPR spectra agree well with predictions, and the performance of the sub-Kelvin system at 5K is compared to that of a commercial spectrometer. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  12. EPR-based distance measurements at ambient temperature

    Science.gov (United States)

    Krumkacheva, Olesya; Bagryanskaya, Elena

    2017-07-01

    Pulsed dipolar (PD) EPR spectroscopy is a powerful technique allowing for distance measurements between spin labels in the range of 2.5-10.0 nm. It was proposed more than 30 years ago, and nowadays is widely used in biophysics and materials science. Until recently, PD EPR experiments were limited to cryogenic temperatures (T biomolecules, the influence of a linker between the spin probe and biomolecule, and future opportunities.

  13. The EPR paradox revisited

    International Nuclear Information System (INIS)

    Cantrell, C.D.; Scully, M.O.

    1978-01-01

    Einstein, Podolsky and Rosen (EPR) argued in 1935 that quantum mechanics fails to give an adequate description of physical reality, and also cannot give a consistent wave-function description of certain phenomena. The authors show that a calculation based upon the reduced density matrix removes the formal inconsistency pointed out by EPR. The spirit of the present paper is that of a pedagogical review. (Auth.)

  14. EPR paradox revisited

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, C.D.; Scully, M.O.

    1978-07-01

    Einstein, Podolsky, and Rosen (EPR) argued in 1935 that quantum mechanics fails to give an adequate description of physical reality, and also cannot give a consistent wave-function description of certain phenomena. It is shown that a calculation based upon the reduced density matrix removes the formal inconsistency pointed out by EPR. The spirit of the present paper is that of a pedagogical review.

  15. The optimisation of analyser geometry for a near back-scattering spectrometer. IRIS on the ISIS pulsed source

    International Nuclear Information System (INIS)

    Telling, M.T.F.; Campbell, S.I.

    1999-01-01

    This report describes the upgrade of the pyrolytic graphite (PG) analyser bank on the IRIS high-resolution inelastic spectrometer at ISIS from 1350 graphite pieces (6 rows by 225 columns) to 4212 crystal pieces (18 rows by 234 columns). The analyser array will achieve a three-fold increase in area and in addition the graphite crystals will be cooled close to liquid helium temperature to reduce thermal diffuse scattering, thereby further improving the sensitivity of the spectrometer. For an instrument such as IRIS, with its analyser out of exact back-scattering geometry, optical aberration and variation in the time-of-flight of the analysed neutrons is introduced as one moves out from the horizontal scattering plane. To minimise such effects, the profile of the analyser array has been redesigned. The concept behind the design of the new analyser bank and the factors that effect the overall resolution of the instrument are discussed. Results of Monte Carlo simulations of the expected resolution and intensity of the complete instrument are presented and compared to the current instrument performance. (author)

  16. Low-temperature binding of NO adsorbed on MIL-100(Al)-A case study for the application of high resolution pulsed EPR methods and DFT calculations.

    Science.gov (United States)

    Mendt, Matthias; Barth, Benjamin; Hartmann, Martin; Pöppl, Andreas

    2017-12-14

    The low-temperature binding of nitric oxide (NO) in the metal-organic framework MIL-100(Al) has been investigated by pulsed electron nuclear double resonance and hyperfine sublevel correlation spectroscopy. Three NO adsorption species have been identified. Among them, one species has been verified experimentally to bind directly to an 27 Al atom and all its relevant 14 N and 27 Al hyperfine interaction parameters have been determined spectroscopically. Those parameters fit well to the calculated ones of a theoretical cluster model, which was derived by density functional theory (DFT) in the present work and describes the low temperature binding of NO to the regular coordinatively unsaturated Al 3+ site of the MIL-100(Al) structure. As a result, the Lewis acidity of that site has been characterized using the NO molecule as an electron paramagnetic resonance active probe. The DFT derived wave function analysis revealed a bent end-on coordination of the NO molecule adsorbed at that site which is almost purely ionic and has a weak binding energy. The calculated flat potential energy surface of this species indicates the ability of the NO molecule to freely rotate at intermediate temperatures while it is still binding to the Al 3+ site. For the other two NO adsorption species, no structural models could be derived, but one of them is indicated to be adsorbed at the organic part of the metal-organic framework. Hyperfine interactions with protons, weakly coupled to the observed NO adsorption species, have also been measured by pulsed electron paramagnetic resonance and found to be consistent with their attribution to protons of the MIL-100(Al) benzenetricarboxylate ligand molecules.

  17. Low-temperature binding of NO adsorbed on MIL-100(Al)—A case study for the application of high resolution pulsed EPR methods and DFT calculations

    Science.gov (United States)

    Mendt, Matthias; Barth, Benjamin; Hartmann, Martin; Pöppl, Andreas

    2017-12-01

    The low-temperature binding of nitric oxide (NO) in the metal-organic framework MIL-100(Al) has been investigated by pulsed electron nuclear double resonance and hyperfine sublevel correlation spectroscopy. Three NO adsorption species have been identified. Among them, one species has been verified experimentally to bind directly to an 27Al atom and all its relevant 14N and 27Al hyperfine interaction parameters have been determined spectroscopically. Those parameters fit well to the calculated ones of a theoretical cluster model, which was derived by density functional theory (DFT) in the present work and describes the low temperature binding of NO to the regular coordinatively unsaturated Al3+ site of the MIL-100(Al) structure. As a result, the Lewis acidity of that site has been characterized using the NO molecule as an electron paramagnetic resonance active probe. The DFT derived wave function analysis revealed a bent end-on coordination of the NO molecule adsorbed at that site which is almost purely ionic and has a weak binding energy. The calculated flat potential energy surface of this species indicates the ability of the NO molecule to freely rotate at intermediate temperatures while it is still binding to the Al3+ site. For the other two NO adsorption species, no structural models could be derived, but one of them is indicated to be adsorbed at the organic part of the metal-organic framework. Hyperfine interactions with protons, weakly coupled to the observed NO adsorption species, have also been measured by pulsed electron paramagnetic resonance and found to be consistent with their attribution to protons of the MIL-100(Al) benzenetricarboxylate ligand molecules.

  18. EPR in characterization of seeds paramagnetic species

    International Nuclear Information System (INIS)

    Luiz, A.P.C.; Mauro, M.F.F.L.; Portugal, K.O.; Barbana, V.M.; Guedes, C.L.B.; Mauro, E. di; Carneiro, C.E.A.; Zaia, D.A.M.; Prete, C.E.C.

    2011-01-01

    Full text. In Brazil, since 1970s, renewable fuel programs has been developed in order to replace petroleum. Today a program that has been discussed is the bio diesel, which intend to replace diesel fuel, fossil oil, to bio diesel, renewal fuel. As seeds are the basis for production of oil and consequently processed into bio diesel, the goal of this work is to characterize and compare paramagnetic species present in the seeds by Electron Paramagnetic Resonance (EPR). Samples used in this study were seeds of sorghum, barley, corn, peanuts, soy beans, cotton, wheat, oats, mustard, rice, sunflower and turnip. Some paramagnetic species present in soil was also investigated as goethite (FeOOH), hematite (Fe 2 O 3 ), magnetite (Fe 3 O 4 ), and ferrihydrite (Fe 5 HO 8 · 4H 2 O), since, these species present in appreciable quantities in the soil can be present in the seeds and analyzed for comparison. The characterization of these species is essential to understand the EPR seeds spectra. Each sample is placed in a thin quartz tube 4 mm in diameter, and it is inserted into the cavity of the spectrometer at room temperature, at low temperature (77 K) and variable temperature using liquid nitrogen flow and hot flow through a compressor air. It was used as standard Mg O:Mn 2+ , which is also inserted into the cavity. Shortly after the potency is regulated, frequency, amplitude and sweep the field. The spectroscopic analysis by EPR X-band (∼ 9:5GHz), were performed at the Fluorescence and Electron Paramagnetic Resonance Laboratory, Exact Sciences Center, State University of Londrina, Parana state, Brazil, through an EPR spectrometer JEOL brand (JES-PE-3X). In the EPR spectra, spectroscopic factor or g factor and line width were determined in paramagnetic species. Studies from several seeds with EPR technique detected in all of them presence of same complex of Fe 3+ present in the goethite at g ∼ 2, and in the seeds exist free radicals at g = 2:004, at room temperature

  19. EPR in characterization of seeds paramagnetic species

    Energy Technology Data Exchange (ETDEWEB)

    Luiz, A.P.C.; Mauro, M.F.F.L.; Portugal, K.O.; Barbana, V.M.; Guedes, C.L.B.; Mauro, E. di; Carneiro, C.E.A.; Zaia, D.A.M.; Prete, C.E.C. [Universidade Estadual de Londrina (UEL), PR (Brazil)

    2011-07-01

    Full text. In Brazil, since 1970s, renewable fuel programs has been developed in order to replace petroleum. Today a program that has been discussed is the bio diesel, which intend to replace diesel fuel, fossil oil, to bio diesel, renewal fuel. As seeds are the basis for production of oil and consequently processed into bio diesel, the goal of this work is to characterize and compare paramagnetic species present in the seeds by Electron Paramagnetic Resonance (EPR). Samples used in this study were seeds of sorghum, barley, corn, peanuts, soy beans, cotton, wheat, oats, mustard, rice, sunflower and turnip. Some paramagnetic species present in soil was also investigated as goethite (FeOOH), hematite (Fe{sub 2}O{sub 3}), magnetite (Fe{sub 3}O{sub 4}), and ferrihydrite (Fe{sub 5}HO{sub 8} {center_dot} 4H{sub 2}O), since, these species present in appreciable quantities in the soil can be present in the seeds and analyzed for comparison. The characterization of these species is essential to understand the EPR seeds spectra. Each sample is placed in a thin quartz tube 4 mm in diameter, and it is inserted into the cavity of the spectrometer at room temperature, at low temperature (77 K) and variable temperature using liquid nitrogen flow and hot flow through a compressor air. It was used as standard Mg O:Mn{sup 2+}, which is also inserted into the cavity. Shortly after the potency is regulated, frequency, amplitude and sweep the field. The spectroscopic analysis by EPR X-band ({approx} 9:5GHz), were performed at the Fluorescence and Electron Paramagnetic Resonance Laboratory, Exact Sciences Center, State University of Londrina, Parana state, Brazil, through an EPR spectrometer JEOL brand (JES-PE-3X). In the EPR spectra, spectroscopic factor or g factor and line width were determined in paramagnetic species. Studies from several seeds with EPR technique detected in all of them presence of same complex of Fe{sup 3+} present in the goethite at g {approx} 2, and in the seeds

  20. EPR ohmic heating energy storage

    International Nuclear Information System (INIS)

    Heck, F.M.; Stillwagon, R.E.; King, E.I.

    1977-01-01

    The Ohmic Heating (OH) Systems for all the Experimental Power Reactor (EPR) designs to date have all used temporary energy storage to assist in providing the OH current charge required to build up the plasma current. The energies involved (0.8 x 10 9 J to 1.9 x 10 9 J) are so large as to make capacitor storage impractical. Two alternative approaches are homopolar dc generators and ac generators. Either of these can be designed for pulse duty and can be made to function in a manner similar to a capacitor in the OH circuit and are therefore potential temporary energy storage devices for OH systems for large tokamaks. This study compared total OH system costs using homopolar and ac generators to determine their relative merits. The total system costs were not significantly different for either type of machine. The added flexibility and the lower maintenance of the ac machine system make it the more attractive approach

  1. Biomolecular EPR spectroscopy

    CERN Document Server

    Hagen, Wilfred Raymond

    2008-01-01

    Comprehensive, Up-to-Date Coverage of Spectroscopy Theory and its Applications to Biological SystemsAlthough a multitude of books have been published about spectroscopy, most of them only occasionally refer to biological systems and the specific problems of biomolecular EPR (bioEPR). Biomolecular EPR Spectroscopy provides a practical introduction to bioEPR and demonstrates how this remarkable tool allows researchers to delve into the structural, functional, and analytical analysis of paramagnetic molecules found in the biochemistry of all species on the planet. A Must-Have Reference in an Intrinsically Multidisciplinary FieldThis authoritative reference seamlessly covers all important bioEPR applications, including low-spin and high-spin metalloproteins, spin traps and spin lables, interaction between active sites, and redox systems. It is loaded with practical tricks as well as do's and don'ts that are based on the author's 30 years of experience in the field. The book also comes with an unprecedented set of...

  2. Fully automated dual-frequency three-pulse-echo 2DIR spectrometer accessing spectral range from 800 to 4000 wavenumbers

    Energy Technology Data Exchange (ETDEWEB)

    Leger, Joel D.; Nyby, Clara M.; Varner, Clyde; Tang, Jianan; Rubtsova, Natalia I.; Yue, Yuankai; Kireev, Victor V.; Burtsev, Viacheslav D.; Qasim, Layla N.; Rubtsov, Igor V., E-mail: irubtsov@tulane.edu [Department of Chemistry, Tulane University, New Orleans, Louisiana 70118 (United States); Rubtsov, Grigory I. [Institute for Nuclear Research of the Russian Academy of Sciences, Moscow 117312 (Russian Federation)

    2014-08-15

    A novel dual-frequency two-dimensional infrared instrument is designed and built that permits three-pulse heterodyned echo measurements of any cross-peak within a spectral range from 800 to 4000 cm{sup −1} to be performed in a fully automated fashion. The superior sensitivity of the instrument is achieved by a combination of spectral interferometry, phase cycling, and closed-loop phase stabilization accurate to ∼70 as. The anharmonicity of smaller than 10{sup −4} cm{sup −1} was recorded for strong carbonyl stretching modes using 800 laser shot accumulations. The novel design of the phase stabilization scheme permits tuning polarizations of the mid-infrared (m-IR) pulses, thus supporting measurements of the angles between vibrational transition dipoles. The automatic frequency tuning is achieved by implementing beam direction stabilization schemes for each m-IR beam, providing better than 50 μrad beam stability, and novel scheme for setting the phase-matching geometry for the m-IR beams at the sample. The errors in the cross-peak amplitudes associated with imperfect phase matching conditions and alignment are found to be at the level of 20%. The instrument can be used by non-specialists in ultrafast spectroscopy.

  3. EPR paradox revisited

    Energy Technology Data Exchange (ETDEWEB)

    Klippert, R. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    1999-07-01

    In a seminal paper from 1935 Einstein, Podolsky and Rosen produced one of the most powerful weapon against the unpredictability of the world ensured by quantum mechanics. The recent production of entangled states, with all its possible future applications in quantum computation, re-open the possibility of testing EPR states on physical grounds. The present intends to present a challenge to the wedding of classical (special) relativity with quantum mechanics, the so called relativistic quantum mechanics. Making use of the same apparatus devised in EPR, it is shown that non local quantum states are incompatible with either their possibility of being measured or else with Lorentz invariance (or even with both). (author)

  4. EPR-based distance measurements at ambient temperature.

    Science.gov (United States)

    Krumkacheva, Olesya; Bagryanskaya, Elena

    2017-07-01

    Pulsed dipolar (PD) EPR spectroscopy is a powerful technique allowing for distance measurements between spin labels in the range of 2.5-10.0nm. It was proposed more than 30years ago, and nowadays is widely used in biophysics and materials science. Until recently, PD EPR experiments were limited to cryogenic temperatures (TEPR as well as other approaches based on EPR (e.g., relaxation enhancement; RE). In this paper, we review the features of PD EPR and RE at ambient temperatures, in particular, requirements on electron spin phase memory time, ways of immobilization of biomolecules, the influence of a linker between the spin probe and biomolecule, and future opportunities. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Spin dynamics of light-induced charge separation in composites of semiconducting polymers and PC60BM revealed using Q-band pulse EPR.

    Science.gov (United States)

    Lukina, E A; Suturina, E; Reijerse, E; Lubitz, W; Kulik, L V

    2017-08-23

    Light-induced processes in composites of semiconducting polymers and fullerene derivatives have been widely studied due to their usage as active layers of organic solar cells. However the process of charge separation under light illumination - the key process of an organic solar cell is not well understood yet. Here we report a Q-band pulse electron paramagnetic resonance study of composites of the fullerene derivative PC 60 BM ([6,6]-phenyl-C 61 -butyric acid methyl ester) with different p-type semiconducting polymers regioregular and regiorandom P3HT (poly(3-hexylthiophene-2,5-diyl), MEH-PPV (poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene]), PCDTBT (poly[N-9'-heptadecanyl-2,7-carbazole-alt-5,5-(4',7'-di-2-thienyl-2',1',3'-benzothiadiazole)]), PTB7 (poly({4,8-bis[(2-ethylhexyl)oxy]benzo[1,2-b:4,5-b']dithiophene-2,6-diyl}{3-fluoro-2-[(2-ethylhexyl)carbonyl]thieno[3,4-b]thiophenediyl}))), resulting in a detailed description of the in-phase laser flash-induced electron spin echo (ESE) signal. We found that in organic donor-acceptor composites the laser flash simultaneously induces species of two types: a polymer˙ + /fullerene˙ - spin-correlated polaron pair (SCPP) with an initial singlet spin state and (nearly) free polymer˙ + and fullerene˙ - species with non-equilibrium spin polarization. Species of the first type (SCPP) are well-known for polymer/fullerene blends and are usually associated with a charge-separated state. Also, spin polarization of long-living free species (polarons in deep traps) is affected by the laser flash, which is the third contribution to the flash-induced ESE signal. A protocol for extracting the in-phase ESE signal of the SCPP based on the dependence of the microwave nutation frequency on the strength of the spin coupling within the polaron pair was developed. Nutation experiments revealed an unusual pattern of the SCPP in RR-P3HT/PC 60 BM composites, from which the strength of the exchange interaction between the polymer

  6. EPR: the nuclear impasse

    International Nuclear Information System (INIS)

    Marillier, F.

    2008-01-01

    The questions relative to the climatic change constitute crucial challenges for the next ten years. In this context the author aims to show how the EPR project illustrates the nuclear french ''autism''. He presents and analyzes the international and environmental impacts of this obsolete technology, as a project useless and dangerous. (A.L.B.)

  7. A superheterodyne spectrometer for electronic paramagnetic. Resonance

    International Nuclear Information System (INIS)

    Laffon, J.L.

    1963-12-01

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [fr

  8. EPR (European Pressurized Reactor)

    International Nuclear Information System (INIS)

    2015-01-01

    This document presents the EPR (European Pressurized Reactor), a modernised version of PWRs which uses nuclear fission. It indicates to which category it belongs (third generation). It briefly describes its operation: recalls on nuclear fission, electricity production in a nuclear reactor. It presents and comments its characteristics: power, thermal efficiency, redundant systems for safety control, double protective enclosure, expected lifetime, use of MOX fuel, modular design. It discusses economic stakes (expected higher nuclear electricity competitiveness, but high construction costs), and safety challenges (design characteristics, critics by nuclear safety authorities about the safety data processing system). It presents the main involved actors (Areva, EDF) and competitors in the field of advanced reactors (Rosatom with its VVER 1200, General Electric with its ABWR and its ESBWR, Mitsubishi with its APWR, Westinghouse with its AP100) while outlining the importance of certifications and delays to obtain them. After having evoked key data on EPR fuel consumption, it indicates reactors under construction, evokes potential markets and perspectives

  9. EPR, kvantemekanik og Bohr

    OpenAIRE

    Nielsen, Morten Klockmann

    2007-01-01

    Dette projekt omhandler området hvor filosofi og fysik smelter sammen. Kvantemekanikkens tilblivelse fik en hård medfart hvilket diskussionerne mellem især Albert Einstein og Niels Bohr vidner om. De var hovedpersoner i striden om hvordan kvantemekanikken skulle fortolkes, og diskussionen kulminerede i 1935 hvor Einstein sammen med kollegerne Podolsky og Rosen offentliggjorde en artikel med titlen “Can Quantum-Mechanical Description of Physical Reality Be Considered Complete?” (EPR-artiklen)....

  10. EPR a strategic choice

    International Nuclear Information System (INIS)

    2003-01-01

    How can we answer to the increasing demand of electric power, resulting of the demographic evolution and needed to the economic development, without exhausting the fossil resources? The answers are function of the countries and imply an optimization of the production and the consumption. This document published by the Areva Group aims to show the advantages of the nuclear energy: economical and environmental advantages. A special chapter is devoted to the European Pressurized Reactor, EPR. (A.L.B.)

  11. Electron paramagnetic resonance (EPR) biodosimetry

    International Nuclear Information System (INIS)

    Desrosiers, Marc; Schauer, David A.

    2001-01-01

    Radiation-induced electron paramagnetic resonance (EPR) signals were first reported by Gordy et al. [Proc. Natl. Acad. Sci. USA 41 (1955) 983]. The application of EPR spectroscopy to ionizing radiation dosimetry was later proposed by Brady et al. [Health Phys. 15 (1968) 43]. Since that time EPR dosimetry has been applied to accident and epidemiologic dose reconstruction, radiation therapy, food irradiation, quality assurance programs and archaeological dating. Materials that have been studied include bone, tooth enamel, alanine and quartz. This review paper presents the fundamentals and applications of EPR biodosimetry. Detailed information regarding sample collection and preparation, EPR measurements, dose reconstruction, and data analysis and interpretation will be reviewed for tooth enamel. Examples of EPR biodosimetry application in accidental overexposures, radiopharmaceutical dose assessment and retrospective epidemiologic studies will also be presented

  12. Development of a new dosimeter of EPR based on lactose

    International Nuclear Information System (INIS)

    Cruz C, L.; Torijano C, E.; Azorin N, J.; Aguirre G, F.; Cruz Z, E.

    2014-08-01

    50 years have passed since was proposed using the amino acid alanine as dosimeter advantage the phenomenon of electron paramagnetic resonance (EPR); this dosimetric method has reached a highly competitive level regarding others dosimetry classic methods, for example the thermoluminescence or the use of Fricke dosimeters, to measure high dose of radiation. In this type of materials, the free radicals induced by the radiation are stable and their concentration is proportional to the absorbed dose may be determined by the amplitude pick to pick of the first derived of the EPR absorption spectrum. The obtained results studying the EPR response of lactose tablets elaborated in the Universidad Autonoma Metropolitana, Unidad Iztapalapa are presented. The tablets were irradiated with gamma radiation of 60 Co in the irradiator Gamma beam 651-Pt of the Instituto de Ciencias Nucleares de la Universidad Nacional Autonoma de Mexico to a dose rate of 8 kGy-h -1 and their EPR response in a EPR spectrometer e-scan Bruker. The obtained response in function of the dose was lineal in the interval of 1 at 10 kGy. The lactose sensibility was compared with the l-alanine, used as reference, and the result was consistently 0.25 of this. Due to the linearity shown in the interval of used dose and their low production cost, we conclude that the lactose is a promissory option for the dosimetry of high dose of radiation. (author)

  13. Quantitative EPR A Practitioners Guide

    CERN Document Server

    Eaton, Gareth R; Barr, David P; Weber, Ralph T

    2010-01-01

    This is the first comprehensive yet practical guide for people who perform quantitative EPR measurements. No existing book provides this level of practical guidance to ensure the successful use of EPR. There is a growing need in both industrial and academic research to provide meaningful and accurate quantitative EPR results. This text discusses the various sample, instrument and software related aspects required for EPR quantitation. Specific topics include: choosing a reference standard, resonator considerations (Q, B1, Bm), power saturation characteristics, sample positioning, and finally, putting all the factors together to obtain an accurate spin concentration of a sample.

  14. Monolithic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rajic, Slobodan (Knoxville, TN); Egert, Charles M. (Oak Ridge, TN); Kahl, William K. (Knoxville, TN); Snyder, Jr., William B. (Knoxville, TN); Evans, III, Boyd M. (Oak Ridge, TN); Marlar, Troy A. (Knoxville, TN); Cunningham, Joseph P. (Oak Ridge, TN)

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  15. EPR design for maintenance

    International Nuclear Information System (INIS)

    Krugmann, U.

    1998-01-01

    Preventive maintenance is very important in achieving high plant availability. For the European Pressurized Reactor (EPR) preventive maintenance has been carefully addressed in the design stage. This is particularly necessary because of the traditionally different maintenance strategies employed in France and Germany. This paper emphasizes the following features introduced in the ERP design to minimize the duration of the refueling outage: (1) containment accessibility during power operation; (2) overall plant layout to facilitate inspections and maintenances within the containment; and (3) safety system design for enabling preventive maintenance during power operation. (author)

  16. Full cycle rapid scan EPR deconvolution algorithm.

    Science.gov (United States)

    Tseytlin, Mark

    2017-08-01

    Rapid scan electron paramagnetic resonance (RS EPR) is a continuous-wave (CW) method that combines narrowband excitation and broadband detection. Sinusoidal magnetic field scans that span the entire EPR spectrum cause electron spin excitations twice during the scan period. Periodic transient RS signals are digitized and time-averaged. Deconvolution of absorption spectrum from the measured full-cycle signal is an ill-posed problem that does not have a stable solution because the magnetic field passes the same EPR line twice per sinusoidal scan during up- and down-field passages. As a result, RS signals consist of two contributions that need to be separated and postprocessed individually. Deconvolution of either of the contributions is a well-posed problem that has a stable solution. The current version of the RS EPR algorithm solves the separation problem by cutting the full-scan signal into two half-period pieces. This imposes a constraint on the experiment; the EPR signal must completely decay by the end of each half-scan in order to not be truncated. The constraint limits the maximum scan frequency and, therefore, the RS signal-to-noise gain. Faster scans permit the use of higher excitation powers without saturating the spin system, translating into a higher EPR sensitivity. A stable, full-scan algorithm is described in this paper that does not require truncation of the periodic response. This algorithm utilizes the additive property of linear systems: the response to a sum of two inputs is equal the sum of responses to each of the inputs separately. Based on this property, the mathematical model for CW RS EPR can be replaced by that of a sum of two independent full-cycle pulsed field-modulated experiments. In each of these experiments, the excitation power equals to zero during either up- or down-field scan. The full-cycle algorithm permits approaching the upper theoretical scan frequency limit; the transient spin system response must decay within the scan

  17. Correlation spectrometer

    Science.gov (United States)

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  18. EPR of uranium ions

    International Nuclear Information System (INIS)

    Ursu, I.; Lupei, V.

    1984-02-01

    A review of the electron paramagnetic resonance data on the uranium ions is given. After a general account of the electronic structure of the uranium free atoms and ions, the influence of the external fields (magnetic field, crystal fields) is discussed. The main information obtained from EPR studies on the uranium ions in crystals are emphasized: identification of the valence and of the ground electronic state, determination of the structure of the centers, crystal field effects, role of the intermediate coupling and of the J-mixing, role of the covalency, determination of the nuclear spin, maqnetic dipole moment and electric quadrupole moment of the odd isotopes of uranium. These data emphasize the fact that the actinide group has its own identity and this is accutely manifested at the beginning of the 5fsup(n) series encompassed by the uranium ions. (authors)

  19. Magnetic field shielding system in a tokamak experimental power reactor (EPR): concept and calculations

    International Nuclear Information System (INIS)

    Peng, Y.K.M.; Marcus, F.B.; Dory, R.A.; Moore, J.R.

    1975-01-01

    A poloidal magnetic field shielding system is proposed for a tokamak EPR. This coil system minimizes the pulsed poloidal field that intersects the TF (toroidal field) coils and hence reduces the risk of superconductor quenching and structural failure of the coils. Based on an idealized shielding model, we have determined the configurations for the OH (ohmic heating), the S-VF (shield-vertical field), and the T-VF (trimming-vertical field) coils in a typical tokamak EPR. It is found that the pulsed poloidal field strength is greatly reduced in the TF coil region. The overall requirement in stored plasma and vertical field energy is also substantially reduced when compared with conventional EPR designs. Use of this field shielding system is expected to enhance reliability of the superconducting TF coils in a tokamak EPR

  20. Multidimensional spectrometer

    Science.gov (United States)

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  1. EPR imaging of dose distributions aiming at applications in radiation therapy

    International Nuclear Information System (INIS)

    Lund, E.; Kolbun, N.; Adolfsson, E.; Gustafsson, H.

    2014-01-01

    A one-dimensional electron paramagnetic resonance (EPR) imaging method for visualisation of dose distributions in photon fields has been developed. Pressed pellets of potassium dithionate were homogeneously irradiated in a 60 Co radiation field to 600 Gy. The EPR analysis was performed with an X-Band (9.6 GHz) Bruker E540 EPR and EPR imaging spectrometer equipped with an E540 GC2X two-axis X-band gradient coil set with gradients along the y axis (along the sample tube) and z axis (along B 0 ) and an ER 4108TMHS resonator. Image reconstruction, including deconvolution, baseline corrections and corrections for the resonator sensitivity, was performed using an in-house-developed Matlab code for the purpose to have a transparent and complete algorithm for image reconstruction. With this method, it is possible to visualise a dose distribution with an accuracy of ∼5 % within ±5 mm from the centre of the resonator. (authors)

  2. EPR Flamanville 3, Site Management

    International Nuclear Information System (INIS)

    Menager, Antoine

    2014-01-01

    Antoine Menager, the EPR Flamanville 3 Site Manager described the organization and the management of the Flamanville site during the construction phase. He placed emphasis on Health and Safety, Environmental and Social Responsibility and on Nuclear Safety and Quality

  3. Towards EPR (European pressurized reactor)

    International Nuclear Information System (INIS)

    Anon.

    2003-01-01

    According to the French industry minister, it is nonsense continuing delaying the construction of an EPR prototype because France needs it in order to renew timely its park of nuclear reactors. The renewing is expected to begin in 2020 and will be assured with third generation reactors like EPR. A quick launching of the EPR prototype is necessary to have it being in service by 2012, the feedback operating experience that will be accumulated over the 8 years that will follow will be necessary to optimize the industrial version and to have it ready by 2020. The EPR reactor has indisputable assets: modern, safer, more competitive and it will produce less wastes than present nuclear reactors. The construction cost of an EPR prototype is estimated to 3 milliard Euros and the nuclear industry operators propose to finance it completely. The EPR prototype does not jeopardize the ambitious French program about renewable energy sources, France is committed to produce 21% of its electricity from renewable energies by 2010 and 10 milliard Euros will be invested over this period on wind energy. Nuclear energy and alternative energies must be considered as 2 aspects of a diversified energy policy. (A.C.)

  4. EPR spectroscopy can help with paint pigment provenance

    International Nuclear Information System (INIS)

    Troup, G.J.; Hutton, D.R.

    2000-01-01

    Full text: The microwave magnetic spectroscopic technique EPR can be used to determine the presence of paramagnetic impurities in paint pigments, and the purity of composition regarding the main colourant. Hence EPR can help determine provenance of pigments, just as it can for gemstones. Specimens of Lapis Lazuli (synthetic, Afghanistan, Chile, Greenland) showed quite recognisably different spectra, at room temperature, in a Varian E-12 X-band spectrometer (9.1 GHz frequency). Similarly, specimens of yellow ochre, two imported into Australia, one North Australian, another 95% pure Goethite, showed recognisably different spectra. The North Australian one uniquely gave a known radiation damage signal from quartz, perhaps to be expected, given the abundance of radioactive ores in the region. Further samples have been obtained and the results from these will be reported

  5. CW EPR parameters reveal cytochrome P450 ligand binding modes.

    Science.gov (United States)

    Lockart, Molly M; Rodriguez, Carlo A; Atkins, William M; Bowman, Michael K

    2018-06-01

    Cytochrome P450 (CYP) monoxygenses utilize heme cofactors to catalyze oxidation reactions. They play a critical role in metabolism of many classes of drugs, are an attractive target for drug development, and mediate several prominent drug interactions. Many substrates and inhibitors alter the spin state of the ferric heme by displacing the heme's axial water ligand in the resting enzyme to yield a five-coordinate iron complex, or they replace the axial water to yield a nitrogen-ligated six-coordinate iron complex, which are traditionally assigned by UV-vis spectroscopy. However, crystal structures and recent pulsed electron paramagnetic resonance (EPR) studies find a few cases where molecules hydrogen bond to the axial water. The water-bridged drug-H 2 O-heme has UV-vis spectra similar to nitrogen-ligated, six-coordinate complexes, but are closer to "reverse type I" complexes described in older liteature. Here, pulsed and continuous wave (CW) EPR demonstrate that water-bridged complexes are remarkably common among a range of nitrogenous drugs or drug fragments that bind to CYP3A4 or CYP2C9. Principal component analysis reveals a distinct clustering of CW EPR spectral parameters for water-bridged complexes. CW EPR reveals heterogeneous mixtures of ligated states, including multiple directly-coordinated complexes and water-bridged complexes. These results suggest that water-bridged complexes are under-represented in CYP structural databases and can have energies similar to other ligation modes. The data indicates that water-bridged binding modes can be identified and distinguished from directly-coordinated binding by CW EPR. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. EPR by Areva. EPR the 1600+ MWe reactor

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This brochure presents the GEN III+ EPR reactor designed by the Areva and Siemens consortium. The EPR reactor is a direct descendent of the well-proven N4 and KONVOI reactors, the most modern reactors in France and Germany. The EPR was designed by teams from KWU/Siemens and Framatome, EDF in France and the major German utilities, working in collaboration with both French and German safety authorities. The EPR integrates the results of decades of R and D programs, in particular those performed by the CEA (French Atomic Energy Commission) and the Karlsruhe Research Center in Germany. The EPR benefits from the experience of several thousand reactor-years of operation of pressurized water reactor technology. This experience has put 87 AREVA PWRs online throughout the world. Innovative Features: - An outer shell covering the reactor building, the spent fuel building and two of the four safeguard buildings provides protection against large commercial or military aircraft crash. - A heavy neutron reflector that surrounds the reactor core lowers uranium consumption. - An axial economizer inside the steam generator allows a high level of steam pressure and therefore high plant efficiency. - A core catcher allows passive collection and retention of the molten core should the reactor vessel fail in the highly unlikely event of a core melt. - A digital technology and a fully computerized control room with an operator friendly man-machine interface improve the reactor protection system.

  7. EPR by Areva. EPR the 1600+ MWe reactor

    International Nuclear Information System (INIS)

    2008-01-01

    This brochure presents the GEN III+ EPR reactor designed by the Areva and Siemens consortium. The EPR reactor is a direct descendent of the well-proven N4 and KONVOI reactors, the most modern reactors in France and Germany. The EPR was designed by teams from KWU/Siemens and Framatome, EDF in France and the major German utilities, working in collaboration with both French and German safety authorities. The EPR integrates the results of decades of R and D programs, in particular those performed by the CEA (French Atomic Energy Commission) and the Karlsruhe Research Center in Germany. The EPR benefits from the experience of several thousand reactor-years of operation of pressurized water reactor technology. This experience has put 87 AREVA PWRs online throughout the world. Innovative Features: - An outer shell covering the reactor building, the spent fuel building and two of the four safeguard buildings provides protection against large commercial or military aircraft crash. - A heavy neutron reflector that surrounds the reactor core lowers uranium consumption. - An axial economizer inside the steam generator allows a high level of steam pressure and therefore high plant efficiency. - A core catcher allows passive collection and retention of the molten core should the reactor vessel fail in the highly unlikely event of a core melt. - A digital technology and a fully computerized control room with an operator friendly man-machine interface improve the reactor protection system

  8. The EPR layout design

    International Nuclear Information System (INIS)

    Mast, U.; Le Carrer, P.Y.

    2001-01-01

    General: The European Pressurised Water Reactor (EPR) is a French - German development for the next generation of Pressurised Water Reactor. The new reactor design is based on the experiences of operation and design of nuclear power plants in both countries. The EPR fulfils enhanced safety standards, higher availability and a longer service life. Utilities aspects: For the Utilities one important requirement is the reduction of personnel exposure during maintenance and in-service inspection. The other significant requirement is of economic nature. The main points influencing costs, which have also impact on the layout, are: outage times, accessibility of the reactor building and the available maintenance and set down areas. The Utilities have also required to load the spent fuel assemblies into the shipping cask from the bottom of the fuel pool, because of the exclusion of the drop of the cask and in order to avoid contamination at the outer cask shell. Layout and safety aspects: All safety relevant Nuclear Island (NI) buildings are designed against design earthquake as well as explosion pressure wave. The protection against Airplane Crash (APC) is realised by civil and layout dispositions. The Reactor Building, the Safeguard Buildings division 2 and 3 and the Fuel Building are protected by concrete structures. The other safety relevant nuclear buildings are protected by geographical separation. Important safety requirements are the further reduction of the probability of severe accidents and the mitigation of such an accident on the plant area. For that, a spreading area for molten corium, a channel from the reactor pit to the spreading area and the In Containment Refuelling Water Storage Tank (IRWST) for flooding and initial cooling of the corium, were implemented in the design of the Reactor Building. Layout results: The following buildings are arranged on a common raft to protect them against design earthquake: Reactor Building (RB), Safeguard Buildings (SAB

  9. Nuclear spin-lattice relaxation in nitroxide spin-label EPR.

    Science.gov (United States)

    Marsh, Derek

    2016-11-01

    Nuclear relaxation is a sensitive monitor of rotational dynamics in spin-label EPR. It also contributes competing saturation transfer pathways in T 1 -exchange spectroscopy, and the determination of paramagnetic relaxation enhancement in site-directed spin labelling. A survey shows that the definition of nitrogen nuclear relaxation rate W n commonly used in the CW-EPR literature for 14 N-nitroxyl spin labels is inconsistent with that currently adopted in time-resolved EPR measurements of saturation recovery. Redefinition of the normalised 14 N spin-lattice relaxation rate, b=W n /(2W e ), preserves the expressions used for CW-EPR, whilst rendering them consistent with expressions for saturation recovery rates in pulsed EPR. Furthermore, values routinely quoted for nuclear relaxation times that are deduced from EPR spectral diffusion rates in 14 N-nitroxyl spin labels do not accord with conventional analysis of spin-lattice relaxation in this three-level system. Expressions for CW-saturation EPR with the revised definitions are summarised. Data on nitrogen nuclear spin-lattice relaxation times are compiled according to the three-level scheme for 14 N-relaxation: T 1 n =1/W n . Results are compared and contrasted with those for the two-level 15 N-nitroxide system. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. The EPR in a few words: all you need to know about the EPR nuclear reactor

    International Nuclear Information System (INIS)

    2009-01-01

    After a brief presentation of the EPR (European - or Evolutionary - Pressurized Reactor) type nuclear reactor, this paper, proposed by the collective group 'Stop EPR', develops the following points: EPR is as dangerous as other reactors; EPR flouts democracy; France's energy demand do not need the construction of EPRs; the construction of EPRs is not a factor of economical and social development; EPR should not be constructed neither in France nor elsewhere and the present building sites should be cancelled; the EPR will not help France to increase its energy independence and protect itself from oil price increases; choosing the EPR is incompatible with the large investments to be made in energy conservation and renewable energies; the EPR is not a solution to climate change; the VHV line corridor that will starts at Flamanville is not justified and poses risks to the environment and public health

  11. Rapid-scan EPR imaging.

    Science.gov (United States)

    Eaton, Sandra S; Shi, Yilin; Woodcock, Lukas; Buchanan, Laura A; McPeak, Joseph; Quine, Richard W; Rinard, George A; Epel, Boris; Halpern, Howard J; Eaton, Gareth R

    2017-07-01

    In rapid-scan EPR the magnetic field or frequency is repeatedly scanned through the spectrum at rates that are much faster than in conventional continuous wave EPR. The signal is directly-detected with a mixer at the source frequency. Rapid-scan EPR is particularly advantageous when the scan rate through resonance is fast relative to electron spin relaxation rates. In such scans, there may be oscillations on the trailing edge of the spectrum. These oscillations can be removed by mathematical deconvolution to recover the slow-scan absorption spectrum. In cases of inhomogeneous broadening, the oscillations may interfere destructively to the extent that they are not visible. The deconvolution can be used even when it is not required, so spectra can be obtained in which some portions of the spectrum are in the rapid-scan regime and some are not. The technology developed for rapid-scan EPR can be applied generally so long as spectra are obtained in the linear response region. The detection of the full spectrum in each scan, the ability to use higher microwave power without saturation, and the noise filtering inherent in coherent averaging results in substantial improvement in signal-to-noise relative to conventional continuous wave spectroscopy, which is particularly advantageous for low-frequency EPR imaging. This overview describes the principles of rapid-scan EPR and the hardware used to generate the spectra. Examples are provided of its application to imaging of nitroxide radicals, diradicals, and spin-trapped radicals at a Larmor frequency of ca. 250MHz. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. EPR: Some History and Clarification

    Science.gov (United States)

    Fine, Arthur

    2002-04-01

    Locality, separation and entanglement 1930s style. We’ll explore the background to the 1935 paper by Einstein, Podolsky and Rosen, how it was composed, the actual argument of the paper, the principles used, and how the paper was received by Schroedinger, and others.We’ll also look at Bohr’s response: the extent to which Bohr connects with what Einstein was after in EPR and the extent to EPR marks a shift in Bohr’s thinking about the quantum theory.

  13. Some ideas on the EPR

    International Nuclear Information System (INIS)

    2003-01-01

    Facing the debate and controversial between partisans and opponents of the European Pressurized Reactor construction, the SFP energy Group aims to offer some reflexions. In this framework the following topics are discussed: the french nuclear park and its replacement, the energy costs, the nuclear reactors profitability, the generation IV reactors. The paper examines then the EPR technology and its cost to conclude on the advantage of an EPR construction, in the case of an energy policy based on the nuclear. This last point seems to be the real challenge of the problem. (A.L.B.)

  14. EPR in B physics and elsewhere

    International Nuclear Information System (INIS)

    Lipkin, H.J.; Tel Aviv Univ.; Argonne National Lab., IL

    1997-01-01

    The application of Einstein-Podolsky-Rosen correlations in Υ(4s) → B anti B decays to research in CP violation is the first and probably only use of EPR as a technique for research in new physics. Elsewhere highly sophisticated EPR projects question EPR and test its predictions to look for violations of quantum mechanics, hidden variables, Bell''s inequalities, etc

  15. Study on the EPR/dosimetric properties of some substituted alanines

    International Nuclear Information System (INIS)

    Gancheva, Veselka; Sagstuen, Einar; Yordanov, Nicola D.

    2006-01-01

    Polycrystalline phenyl-alanine and perdeuterated l-α-alanine (l-α-alanine-d 4 ) were studied as potential high-energy radiation-sensitive materials (RSM) for solid state/EPR dosimetry. It was found that phenyl-alanine exhibits a linear dose response in the dose region 0.1-17kGy. However, phenyl-alanine is about 10 times less sensitive to γ-irradiation than standard l-α-alanine irradiated at the same doses. Moreover, the EPR response from phenyl-alanine is unstable and, independent of the absorbed dose, decreases by about 50% within 20 days after irradiation upon storage at room temperature. γ-irradiated polycrystalline perdeuterated l-α-alanine (CD 3 CD(NH 2 )COOH) has not previously been studied at room temperature by EPR spectroscopy. The first part of the present analysis was with respect to the structure of the EPR spectrum. By spectrum simulations, the presence of at least two radiation induced free radicals, R 1 =CH 3 C*(H)COOH and R 2 =H 3 N + -C*(CH 3 )COO - , was confirmed very clearly. Both these radicals were suggested previously from EPR and ENDOR studies of standard alanine crystals. The further investigations into the potential use of alanine-d 4 as RSM, after choosing optimal EPR spectrometer settings parameters for this purpose, show that it is ca. two times more sensitive than standard l-α-alanine

  16. Alanine-EPR as a transfer standard dosimetry system for low energy X radiation

    International Nuclear Information System (INIS)

    Khoury, H.J.; Silva, E.J. da; Mehta, K.; Barros, V.S. de; Asfora, V.K.; Guzzo, P.L.; Parker, A.G.

    2015-01-01

    The purpose of this paper is to evaluate the use of alanine-EPR as a transfer standard dosimetry system for low energy X radiation, such as that in RS-2400, which operates in the range from 25 to 150 kV and 2 to 45 mA. Two types of alanine dosimeters were investigated. One is a commercial alanine pellets from Aérial-Centre de Ressources Technologiques, France and one was prepared in our laboratory (LMRI-DEN/UFPE). The EPR spectra of the irradiated dosimeters were recorded in the Nuclear Energy Department of UFPE, using a Bruker EMX10 EPR spectrometer operating in the X-band. The alanine-EPR dosimetry system was calibrated in the range of 20–220 Gy in this X-ray field, against an ionization chamber calibrated at the relevant X-ray energy with traceability to PTB. The results showed that both alanine dosimeters presented a linear dose response the same sensitivity, when the EPR signal was normalized to alanine mass. The total uncertainty in the measured dose was estimated to be about 3%. The results indicate that it is possible to use the alanine-EPR dosimetry system for validation of a low-energy X ray irradiator, such as RS-2400.

  17. Skew Projection of Echo-Detected EPR Spectra for Increased Sensitivity and Resolution

    Science.gov (United States)

    Bowman, Michael K.; Krzyaniak, Matthew D.; Cruce, Alex A.; Weber, Ralph T.

    2013-01-01

    The measurement of EPR spectra during pulsed EPR experiments is commonly accomplished by recording the integral of the electron spin echo as the applied magnetic field is stepped through the spectrum. This approach to echo-detected EPR spectral measurement (ED-EPR) limits sensitivity and spectral resolution and can cause gross distortions in the resulting spectra because some of the information present in the electron spin echo is discarded in such measurements. However, Fourier Transformation of echo shapes measured at a series of magnetic field values followed by skew projection onto either a magnetic field or resonance frequency axis can increase both spectral resolution and sensitivity without the need to trade one against the other. Examples of skew-projected spectra with single crystals, glasses and powders show resolution improvements as large as a factor of seven with sensitivity increases of as much as a factor of five. PMID:23644351

  18. EPR: the nuclear impasse; EPR: l'impasse nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Marillier, F [Association Ecologiste Greenpeace (France)

    2008-07-01

    The questions relative to the climatic change constitute crucial challenges for the next ten years. In this context the author aims to show how the EPR project illustrates the nuclear french ''autism''. He presents and analyzes the international and environmental impacts of this obsolete technology, as a project useless and dangerous. (A.L.B.)

  19. EPR: the nuclear impasse; EPR: l'impasse nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Marillier, F. [Association Ecologiste Greenpeace (France)

    2008-07-01

    The questions relative to the climatic change constitute crucial challenges for the next ten years. In this context the author aims to show how the EPR project illustrates the nuclear french ''autism''. He presents and analyzes the international and environmental impacts of this obsolete technology, as a project useless and dangerous. (A.L.B.)

  20. Detection by EPR method of radiation treatment in dried fruits containing crystalline sugar

    International Nuclear Information System (INIS)

    Lehner, K.; Stachowicz, W.

    2006-01-01

    The results of EPR (electron paramagnetic resonance) measurements are presented on the detection ability and stability of radiation induced sugar-born radicals in the samples of dried (dehydrated) fruits available in the market and related to doses of 0.5, 1 and 3 kGy, respectively. The experiments have been conducted during 12 months of storage. Measurements were done with an EPR - 10 MINI spectrometer in X band (frequency of microwaves 9.5 GHz), St. Petersburg Instruments Ltd. The aim of the work was to prove the reliability of acceptability of the method in routine control of irradiated food. (author)

  1. Time-resolved EPR study of singlet oxygen in the gas phase.

    Science.gov (United States)

    Ruzzi, Marco; Sartori, Elena; Moscatelli, Alberto; Khudyakov, Igor V; Turro, Nicholas J

    2013-06-27

    X-band EPR spectra of singlet O2((1)Δg) and triplet O2((3)Σg(-)) were observed in the gas phase under low molecular-oxygen pressures PO2 = 0.175-0.625 Torr, T = 293-323 K. O2((1)Δg) was produced by quenching of photogenerated triplet sensitizers naphthalene C8H10, perdeuterated naphthalene, and perfluoronaphthalene in the gas phase. The EPR spectrum of O2((1)Δg) was also observed under microwave discharge. Integrated intensities and line widths of individual components of the EPR spectrum of O2((3)Σg(-)) were used as internal standards for estimating the concentration of O2 species and PO2 in the EPR cavity. Time-resolved (TR) EPR experiments of C8H10 were the main focus of this Article. Pulsed irradiation of C8H10 in the presence of O2((3)Σg(-)) allowed us to determine the kinetics of formation and decay for each of the four components of the O2((1)Δg) EPR signal, which lasted for only a few seconds. We found that the kinetics of EPR-component decay fit nicely to a biexponential kinetics law. The TR EPR 2D spectrum of the third component of the O2((1)Δg) EPR spectrum was examined in experiments using C8H10. This spectrum vividly presents the time evolution of an EPR component. The largest EPR signal and the longest lifetime of O2((1)Δg), τ = 0.4 s, were observed at medium pressure PO2 = 0.4 Torr, T = 293 K. The mechanism of O2((1)Δg) decay in the presence of photosensitizers is discussed. EPR spectra of O2((1)Δg) evidence that the spin-rotational states of O2((1)Δg) are populated according to Boltzmann distribution in the studied time range of 10-100 ms. We believe that this is the first report dealing with the dependence of O2((1)Δg) EPR line width on PO2 and T.

  2. Characterization of beer flavour stability (EPR - spin trapping)

    International Nuclear Information System (INIS)

    Stasko, A.; Liptakova, M.; Malik, F.

    1999-01-01

    The beer flavour stability is coupled with free radical degradation processes. Probably, aldehydes produced during the brewery but also generated by stalling are responsible for beer flavour as well as for its breaking down. The storing beer at the lower temperatures and in the dark place inhibits, and otherwise the rising temperature and illumination accelerate the rate of such radical processes. Beers contain naturally occurring radical scavengers - antioxidants which inhibit such unwanted reactions. Then depleting of scavengers results in the breaking down of the beer stability. EPR spin trapping technique was used as monitor such processes and for characterising so the flavour stability of beer. The probe was temperated at 60 grad C in the cavity of EPR spectrometer in the presence of spin trapping agent, N-tert.-butyl-α-phenyl nitrone (PBN) and EPR spectra were recorded for few hours. After beer antioxidants become depleted, free radicals formed by the beer degradation are scavenged by PBN spin trap and this point is characterised with a dramatically increased concentration of the free radicals trapped

  3. HISS spectrometer

    International Nuclear Information System (INIS)

    Greiner, D.E.

    1984-11-01

    This talk describes the Heavy Ion Spectrometer System (HISS) facility at the Lawrence Berkeley Laboratory's Bevalac. Three completed experiments and their results are illustrated. The second half of the talk is a detailed discussion of the response of drift chambers to heavy ions. The limitations of trajectory measurement over a large range in incident particle charge are presented

  4. EPR correlations and EPW distributions

    International Nuclear Information System (INIS)

    Bell, J.S.

    1995-01-01

    In the case of two free spin-zero particles, the wave function originally considered by Einstein, Podolsky and Rosen to exemplify EPR correlations has a non-negative Wigner distribution. This distribution gives an explicitly local account of the correlations. For an irreducible non-locality, more elaborate wave functions are required, with Wigner distributions which are not non-negative. (author)

  5. EPR measurements in irradiated polyacetylene

    International Nuclear Information System (INIS)

    Hola, O.; Foeldesova, M.

    1990-01-01

    The influence of γ-irradiation on the paramagnetic properties of polyacetylene, and the dependence of the EPR spectra on the radiation dose in samples of irradiated polyacetylene were studied. The measurements show that no essential changes of the spin mobility occurred during irradiation. (author) 3 refs.; 2 figs

  6. EPR study of human hair

    Czech Academy of Sciences Publication Activity Database

    Křížová, Jana; Káfuňková, Eva; Stopka, Pavel

    2005-01-01

    Roč. 99, č. 14 (2005), s. 217-218 ISSN 0009-2770 R&D Projects: GA MZd(CZ) NL7567; GA MZd(CZ) NB7377 Institutional research plan: CEZ:AV0Z40320502 Keywords : EPR Subject RIV: CA - Inorganic Chemistry Impact factor: 0.445, year: 2005

  7. Use of EPR to Solve Biochemical Problems

    Science.gov (United States)

    Sahu, Indra D.; McCarrick, Robert M.; Lorigan, Gary A.

    2013-01-01

    EPR spectroscopy is a very powerful biophysical tool that can provide valuable structural and dynamic information on a wide variety of biological systems. The intent of this review is to provide a general overview for biochemists and biological researchers on the most commonly used EPR methods and how these techniques can be used to answer important biological questions. The topics discussed could easily fill one or more textbooks; thus, we present a brief background on several important biological EPR techniques and an overview of several interesting studies that have successfully used EPR to solve pertinent biological problems. The review consists of the following sections: an introduction to EPR techniques, spin labeling methods, and studies of naturally occurring organic radicals and EPR active transition metal systems which are presented as a series of case studies in which EPR spectroscopy has been used to greatly further our understanding of several important biological systems. PMID:23961941

  8. EPR Imaging at a Few Megahertz Using SQUID Detectors

    Science.gov (United States)

    Hahn, Inseob; Day, Peter; Penanen, Konstantin; Eom, Byeong Ho

    2010-01-01

    An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use

  9. Field-swept pulsed electron paramagnetic resonance of Cr3+-doped ZBLAN fluoride glass

    International Nuclear Information System (INIS)

    Drew, S.C.; Pilbrow, J.R.; Newman, P.J.; MacFarlane, D.R.

    2001-01-01

    Field-swept pulsed electron paramagnetic resonance (EPR) spectra of a ZBLAN fluoride glass doped with a low concentration of Cr 3+ are obtained using echo-detected EPR and hole-burning free induction decay detection. We review the utility of the pulsed EPR technique in generating field-swept EPR spectra, as well as some of the distorting effects that are peculiar to the pulsed detection method. The application of this technique to Cr 3+ -doped ZBLAN reveals that much of the broad resonance extending from g eff =5.1 to g eff =1.97, characteristic of X-band continuous wave EPR of Cr 3+ in glasses, is absent. We attribute this largely to the variation in nutation frequencies across the spectrum that result from sites possessing large fine structure interactions. The description of the spin dynamics of such sites is complicated and we discuss some possible approaches to the simulation of the pulsed EPR spectra. (author)

  10. Electron volt neutron spectrometers

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Senesi, R.

    2011-01-01

    The advent of pulsed neutron sources has made available intense fluxes of epithermal neutrons (500 meV ≤E≤100 eV ). The possibility to open new investigations on condensed matter with eV neutron scattering techniques, is related to the development of methods, concepts and devices that drive, or are inspired by, emerging studies at this energy scale. Electron volt spectrometers have undergone continuous improvements since the construction of the first prototype instruments, but in the last decade major breakthroughs have been accomplished in terms of resolution and counting statistics, leading, for example, to the direct measurement of the proton 3-D Born–Oppenheimer potential in any material, or to quantitatively probe nuclear quantum effects in hydrogen bonded systems. This paper reports on the most effective methods and concepts for energy analysis and detection, as well as devices for the optimization of electron volt spectrometers for different applications. This is set in the context of the progress made up to date in instrument development. Starting from early stages of development of the technique, particular emphasis will be given to the Vesuvio eV spectrometer at the ISIS neutron source, the first spectrometer where extensive scientific, as well as research and development programmes have been carried out. The potential offered by this type of instrumentation, from single particle excitations to momentum distribution studies, is then put in perspective into the emerging fields of eV spectroscopy applied to cultural heritages and neutron irradiation effects in electronics. - Highlights: ► Neutron spectrometers at eV energies. ► Methods and techniques for eV neutrons counting at spallation sources. ► Scattering, imaging and radiation hardness tests with multi-eV neutrons.

  11. Copper ESEEM and HYSCORE through ultra-wideband chirp EPR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Segawa, Takuya F.; Doll, Andrin; Pribitzer, Stephan; Jeschke, Gunnar, E-mail: gjeschke@ethz.ch [ETH Zurich, Laboratory of Physical Chemistry, Vladimir-Prelog-Weg 2, CH-8093 Zurich (Switzerland)

    2015-07-28

    The main limitation of pulse electron paramagnetic resonance (EPR) spectroscopy is its narrow excitation bandwidth. Ultra-wideband (UWB) excitation with frequency-swept chirp pulses over several hundreds of megahertz overcomes this drawback. This allows to excite electron spin echo envelope modulation (ESEEM) from paramagnetic copper centers in crystals, whereas up to now, only ESEEM of ligand nuclei like protons or nitrogens at lower frequencies could be detected. ESEEM spectra are recorded as two-dimensional correlation experiments, since the full digitization of the electron spin echo provides an additional Fourier transform EPR dimension. Thus, UWB hyperfine-sublevel correlation experiments generate a novel three-dimensional EPR-correlated nuclear modulation spectrum.

  12. EPR-technical codes - a common basis for the EPR

    International Nuclear Information System (INIS)

    Zaiss, W.; Appell, B.

    1997-01-01

    The design and construction of Nuclear Power Plants implies a full set of codes and standards to define the construction rules of components and equipment. Rules are existing and are currently implemented, respectively in France and Germany (mainly RCCs and KTA safety standards). In the frame of the EPR-project, the common objective requires an essential industrial work programme between engineers from both countries to elaborate a common set of codes and regulations. These new industrial rules are called the ETCs (EPR Technical Codes). In the hierarchy the ETCs are - in case of France - on the common level of basic safety rules (RFS), design and construction rules (RCC) and - in Germany - belonging to RSK guidelines and KTA safety standards. A set of six ETCs will be elaborated to cover: safety and process, mechanical components, electrical equipment, instrumentation and control, civil works, fire protection. (orig.)

  13. The Flamanville 3 EPR reactor; Le reacteur EPR Flamanville 3

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    On April 10. 2007, the french government authorized EDF to create on the site of Flamanville ( La Manche) a nuclear base installation containing a pressurized water EPR type reactor. This nuclear reactor, conceived by AREVA NP and EDF, is the first copy of a generation susceptible to replace later, at least partly, the French nuclear reactors at present in operation.Within the framework of its mission of technical support of the Authority of Nuclear Safety ( A.S.N.), the I.R.S.N. widely contributed successively: to define the general objectives of safety assigned to this new generation of pressurized water nuclear reactors; to analyze the options of safety proposed by EDF for the EPR project; To deepen, upstream to the authorization of creation, the evaluation of the step of safety and the measures of conception retained by EDF that have to allow to respect the objectives of safety which were notified to it. (N.C.)

  14. The Spectrometer

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  15. Photoinduced electron transfer to fullerene C70 (An in situ EPR study)

    International Nuclear Information System (INIS)

    Brezova, V.; Dvoranova, D.; Kostova, B.; Stasko, A.

    1999-01-01

    The photoexcitation of fullerene C 70 by monochromatic light (λ = 546 nm) in the presence of electron donating substrate 3,3',5,5'-tetramethyl-benzidine (TMB) resulted in the charge-transfer, quenching the fullerene triplet state and forming corresponding C 70 anion-radicals. Analogously to the photo-reduction of C 60 , two EPR signal were observed upon in situ irradiation in the cavity of EPR spectrometer. EPR singlet A characterized by g-value, g A = 2.0009 and peak-to-peak line-width, pp A = 0.013 mT was assigned to the C 70 mono-anion. Signal B (g B = 2.0011; pp B = 0.011 mT) was tentatively attributed to the C 70 di-anion or to the associated forms of mono-anions. The stabilization of photo-generated anion-radicals significantly depends on solvent polarity. (authors)

  16. EPR of gamma-irradiated polycrystalline alanine-in-glass dosimeter

    International Nuclear Information System (INIS)

    Al-Karmi, Anan M.; Morsy, M.A.

    2008-01-01

    This study attempts to overcome some of the reported discrepancies in alanine-EPR reproducibility that may be related to alanine dosimeter preparation and/or EPR spectrometer settings. The dosimeters were prepared by packing pure polycrystalline L-α-alanine directly as supplied by the manufacturer in glass tubes. This dosimeter production scheme avoids any possible contribution to the EPR signal from a binding material. The dosimeters were irradiated with gamma ray to low-dose ranges typical for medical therapy (0-20 Gy). Special attention has been paid to the study of minimum detectable dose, measurement repeatability and reproducibility, and post-irradiation stability. The dosimeter exhibited a linear dose response in the dose range from 0.1 to 20 Gy. These positive properties favor the polycrystalline alanine-in-glass tube as a radiation dosimeter

  17. EPR compared to international requirements (Mainly EUR)

    International Nuclear Information System (INIS)

    Broecker, B.

    1996-01-01

    A number of European Utilities have entered an agreement to write common requirements dedicated to future light water nuclear power plants to be built in Europe. The activities are known under the sign EUR (European Utilities Requirements). EPR, the future European Pressurized water Reactor, is the first installation of this type which will be operational from the year 2000 onwards, must fulfill the European requirements. EPR will serve as a test whether these requirements are realistic and well balanced. At the basic design stage of EPR, this paper concentrates on four main topics: the requirements which are new compared with existing reactors and which put a major challenge to the designer; the requirements today still open and the way they can be met by the EPR or not; the points for which already today the EPR special requirements exceed the EUR; the examples where the design of the EPR has given feedback which has led to a change of the EUR. EPR and EUR are different approaches to the reactor of the future. EUR is a set of requirements which leaves a flexibility to the designer while EPR is a real project which defines the technical solutions. EPR will fulfill the EUR and will at the same time serve as a test whether these requirements are realistic. EPR will also fulfill international requirements with minor changes. (J.S.). 7 figs

  18. Spectrometer for neutron inelastic scattering investigations of microsamples

    International Nuclear Information System (INIS)

    Balagurov, A.M.; Kozlenko, D.P.; Platonov, S.L.; Savenko, B.N.; Glazkov, V.P.; Krasnikov, Yu.M.; Naumov, I.V.; Pukhov, A.V.; Somenkov, V.A.; Syrykh, G.F.

    1997-01-01

    A new neutron spectrometer for investigation of inelastic neutron scattering on polycrystal microsamples under high pressure in sapphire and diamond anvils cells is described. The spectrometer is operating at the IBR-2 pulsed reactor in JINR. Parameters and methodical peculiarities of the spectrometer and the examples of experimental studies are given. (author)

  19. Antibacterial ethylene propylene rubber impregnated with silver nanopowder: AgNP@EPR

    Directory of Open Access Journals (Sweden)

    Marzieh Miranzadeh

    2016-01-01

    Full Text Available Following our interest in reaching for a molded rubber article with possible detergent contact applications, durable silver nanopowder (AgNP is synthesized by arc discharge, then mixed with varying ratios of ethylene propylene rubber (EPR, affording novel AgNP@EPR nanocomposites. X-ray diffraction (XRD patterns of AgNP as well as AgNP@EPR show no trace of impurity, while scanning electron microscopy (SEM indicates an average diameter of 50 nm for the former. Transmission electron microscopy (TEM images while confirm the SEM results, show quite a few 5 nm AgNP particles lying beside some micro crumbs. Our DC arc discharge technique involves explosion of movable silver anode and static cathode by a current pulse between 5 to 10 A cm-2. A solution blending method is employed for preparation of AgNP@EPR nanocomposites. The AgNP is first dispersed in toluene using an ultrasonic homogenizer, and then thoroughly mixed with EPR in the same solvent whose removal gives nanocomposites of 2, 4, 6 and 8 vol% AgNP in EPR,  showing strong antibacterial activity against both Escherichia coli and Staphylococcus aureus.

  20. Hydrogen Analyses in the EPR

    International Nuclear Information System (INIS)

    Worapittayaporn, S.; Eyink, J.; Movahed, M.

    2008-01-01

    In severe accidents with core melting large amounts of hydrogen may be released into the containment. The EPR provides a combustible gas control system to prevent hydrogen combustion modes with the potential to challenge the containment integrity due to excessive pressure and temperature loads. This paper outlines the approach for the verification of the effectiveness and efficiency of this system. Specifically, the justification is a multi-step approach. It involves the deployment of integral codes, lumped parameter containment codes and CFD codes and the use of the sigma criterion, which provides the link to the broad experimental data base for flame acceleration (FA) and deflagration to detonation transition (DDT). The procedure is illustrated with an example. The performed analyses show that hydrogen combustion at any time does not lead to pressure or temperature loads that threaten the containment integrity of the EPR. (authors)

  1. EPR dosimetry of irradiated human teeth

    International Nuclear Information System (INIS)

    Rodas Duran, J.E.; Panzeri, H.; Mascarenhas, S.

    1985-01-01

    The determination of the absorbed radiation dose in man may be made by Electron Paramagnetic Resonance (EPR) spectroscopy of dental enamel. We analysed the EPR signals for dental enamel submitted to gamma radiation in doses between 1 Gy and 25 Gy. We conclude that independent of the type of tooth analysed there exists a linear relation between the EPR signals and the absorbed doses. These studies were extended to enamel irradiated with gamma rays and with X rays in doses between 0.1 Gy and 0.6 Gy. The graph of the intensity of the EPR signals as a function of the dose has a slope of 0.22. This calibration may be used to calculate the absorbed dose for humans from a measurement of the EPR signal from small samples of enamel taken from any permanent tooth. Finally we comment on some EPR studies of effects of radiation of milk teeth. (author)

  2. EPR studies of melanin from Cladosporium cladosporioides

    International Nuclear Information System (INIS)

    Pilawa, B.; Buszman, E.; Latocha, M.; Wilczok, T.

    1996-01-01

    Free radical properties of Cladosporium cladosporioides mycelium and melanin, and synthetic eumelanin and pheomelanin were studied by electron paramagnetic resonance method. Single EPR line and complex EPR spectrum with hyperfine splitting were measured for model DOPA-melanin and cysteinyldopa-melanin, respectively. EPR spectra of Cladosporium cladosporioides samples and pheomelanin show the same character. The concentration of paramagnetic centers in melanins isolated from Cladosporium cladosporioides is considerably higher than that of crude mycelium, whereas the EPR line widths are lower for mycelium than for melanin samples. For all analyzed samples the increase of EPR signals intensity with the increase of microwave power, and the decrease of intensities after saturation were observed the low values of microwave power sufficient for EPR lines saturation demonstrate that the spin-lattice relaxation times of unpaired electrons in melanins are long. (author)

  3. Calibration of high-dynamic-range, finite-resolution x-ray pulse-height spectrometers for extracting electron energy distribution data from the PFRC-2 device

    Science.gov (United States)

    Swanson, C.; Jandovitz, P.; Cohen, S. A.

    2017-10-01

    Knowledge of the full x-ray energy distribution function (XEDF) emitted from a plasma over a large dynamic range of energies can yield valuable insights about the electron energy distribution function (EEDF) of that plasma and the dynamic processes that create them. X-ray pulse height detectors such as Amptek's X-123 Fast SDD with Silicon Nitride window can detect x-rays in the range of 200eV to 100s of keV. However, extracting EEDF from this measurement requires precise knowledge of the detector's response function. This response function, including the energy scale calibration, the window transmission function, and the resolution function, can be measured directly. We describe measurements of this function from x-rays from a mono-energetic electron beam in a purpose-built gas-target x-ray tube. Large-Z effects such as line radiation, nuclear charge screening, and polarizational Bremsstrahlung are discussed.

  4. Pharmaceutical applications of in vivo EPR

    International Nuclear Information System (INIS)

    Maeder, K.

    1998-01-01

    The aim of this article is to discuss the applications of in vivo EPR in the field of pharmacy. In addition to direct detection of free radical metabolites and measurement of oxygen, EPR can be used to characterize the mechanisms of drug release from biodegradable polymers. Unique information about drug concentration, the microenvironment (viscosity, polarity, pH) and biodistribution (by localized measurement or EPR Imaging) can be obtained. (author)

  5. EPR-based material modelling of soils

    Science.gov (United States)

    Faramarzi, Asaad; Alani, Amir M.

    2013-04-01

    In the past few decades, as a result of the rapid developments in computational software and hardware, alternative computer aided pattern recognition approaches have been introduced to modelling many engineering problems, including constitutive modelling of materials. The main idea behind pattern recognition systems is that they learn adaptively from experience and extract various discriminants, each appropriate for its purpose. In this work an approach is presented for developing material models for soils based on evolutionary polynomial regression (EPR). EPR is a recently developed hybrid data mining technique that searches for structured mathematical equations (representing the behaviour of a system) using genetic algorithm and the least squares method. Stress-strain data from triaxial tests are used to train and develop EPR-based material models for soil. The developed models are compared with some of the well-known conventional material models and it is shown that EPR-based models can provide a better prediction for the behaviour of soils. The main benefits of using EPR-based material models are that it provides a unified approach to constitutive modelling of all materials (i.e., all aspects of material behaviour can be implemented within a unified environment of an EPR model); it does not require any arbitrary choice of constitutive (mathematical) models. In EPR-based material models there are no material parameters to be identified. As the model is trained directly from experimental data therefore, EPR-based material models are the shortest route from experimental research (data) to numerical modelling. Another advantage of EPR-based constitutive model is that as more experimental data become available, the quality of the EPR prediction can be improved by learning from the additional data, and therefore, the EPR model can become more effective and robust. The developed EPR-based material models can be incorporated in finite element (FE) analysis.

  6. High-frequency EPR of surface impurities on nanodiamond

    Science.gov (United States)

    Peng, Zaili; Stepanov, Viktor; Takahashi, Susumu

    Diamond is a fascinating material, hosting nitrogen-vacancy (NV) defect centers with unique magnetic and optical properties. There have been many reports that suggest the existence of paramagnetic impurities near surface of various kinds of diamonds. Electron paramagnetic resonance (EPR) investigation of mechanically crushed nanodiamonds (NDs) as well as detonation NDs revealed g 2 like signals that are attributed to structural defects and dangling bonds near the diamond surface. In this presentation, we investigate paramagnetic impurities in various sizes of NDs using high-frequency (HF) continuous wave (cw) and pulsed EPR spectroscopy. Strong size dependence on the linewidth of HF cw EPR spectra reveals the existence of paramagnetic impurities in the vicinity of the diamond surface. We also study the size dependence of the spin-lattice and spin-spin relaxation times (T1 and T2) of single substitutional nitrogen defects in NDs Significant deviations from the temperature dependence of the phonon-assisted T1 process were observed in the ND samples, and were attributed to the contribution from the surface impurities. This work was supported by the Searle Scholars Program and the National Science Foundation (DMR-1508661 and CHE-1611134).

  7. Optimization of bicelle lipid composition and temperature for EPR spectroscopy of aligned membranes.

    Science.gov (United States)

    McCaffrey, Jesse E; James, Zachary M; Thomas, David D

    2015-01-01

    We have optimized the magnetic alignment of phospholipid bilayered micelles (bicelles) for EPR spectroscopy, by varying lipid composition and temperature. Bicelles have been extensively used in NMR spectroscopy for several decades, in order to obtain aligned samples in a near-native membrane environment and take advantage of the intrinsic sensitivity of magnetic resonance to molecular orientation. Recently, bicelles have also seen increasing use in EPR, which offers superior sensitivity and orientational resolution. However, the low magnetic field strength (less than 1 T) of most conventional EPR spectrometers results in homogeneously oriented bicelles only at a temperature well above physiological. To optimize bicelle composition for magnetic alignment at reduced temperature, we prepared bicelles containing varying ratios of saturated (DMPC) and unsaturated (POPC) phospholipids, using EPR spectra of a spin-labeled fatty acid to assess alignment as a function of lipid composition and temperature. Spectral analysis showed that bicelles containing an equimolar mixture of DMPC and POPC homogeneously align at 298 K, 20 K lower than conventional DMPC-only bicelles. It is now possible to perform EPR studies of membrane protein structure and dynamics in well-aligned bicelles at physiological temperatures and below. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation

    Science.gov (United States)

    Williams, Benjamin B.; Dong, Ruhong; Nicolalde, Roberto J.; Matthews, Thomas P.; Gladstone, David J.; Demidenko, Eugene; Zaki, Bassem I.; Salikhov, Ildar K.; Lesniewski, Piotr N.; Swartz, Harold M.

    2014-01-01

    Purpose The ability to estimate individual exposures to radiation following a large attack or incident has been identified as a necessity for rational and effective emergency medical response. In vivo electron paramagnetic resonance (EPR) spectroscopy of tooth enamel has been developed to meet this need. Materials and methods A novel transportable EPR spectrometer, developed to facilitate tooth dosimetry in an emergency response setting, was used to measure upper incisors in a model system, in unirradiated subjects, and in patients who had received total body doses of 2 Gy. Results A linear dose response was observed in the model system. A statistically significant increase in the intensity of the radiation-induced EPR signal was observed in irradiated versus unirradiated subjects, with an estimated standard error of dose prediction of 0.9 + 0.3 Gy. Conclusions These results demonstrate the current ability of in vivo EPR tooth dosimetry to distinguish between subjects who have not been irradiated and those who have received exposures that place them at risk for acute radiation syndrome. Procedural and technical developments to further increase the precision of dose estimation and ensure reliable operation in the emergency setting are underway. With these developments EPR tooth dosimetry is likely to be a valuable resource for triage following potential radiation exposure of a large population. PMID:21696339

  9. Electron paramagnetic resonance (EPR) in medical dosimetry

    International Nuclear Information System (INIS)

    Schauer, David A.; Iwasaki, Akinori; Romanyukha, Alexander A.; Swartz, Harold M.; Onori, Sandro

    2006-01-01

    This paper describes the fundamentals of electron paramagnetic resonance (EPR) and its application to retrospective measurements of clinically significant doses of ionizing radiation. X-band is the most widely used in EPR dosimetry because it represents a good compromise between sensitivity, sample size and water content in the sample. Higher frequency bands (e.g., W and Q) provide higher sensitivity, but they are also greatly influenced by water content. L and S bands can be used for EPR measurements in samples with high water content but they are less sensitive than X-band. Quality control for therapeutic radiation facilities using X-band EPR spectrometry of alanine is also presented

  10. Characterization of the factors having an influence on the evolution of the EPR signal of irradiated alanine

    International Nuclear Information System (INIS)

    Feaugas-Le-Berre, Valerie

    1999-01-01

    EPR/alanine dosimetry has been used by the LNHB (Laboratoire National Henri Becquerel) since many years for applied metrology. This technic is based on the measurement of the EPR signal of the free radicals induced in alanine by irradiation. The aim of this work is to characterize the factors having an influence on the evolution of the amplitude of the EPR signal of irradiated alanine to limit the uncertainties on the determination of the absorbed dose. The first step of this work has been the choice of the dosimeter. A bibliographic study completed by experiments on the response of alanine isomers to the dose and on its stability with time has lead us to choose L-α-alanine powder as dosimeter. The influence of the recording parameter of the spectrometer on the characteristics of the EPR spectrum has then been studied. This has enabled us to optimize the recording conditions of EPR spectra. As the angular anisotropy of the EPR signal limits the measurements reproducibility, an experimental protocol has been defined to solve this problem. The repeatability of the measurements has been enhanced by modifying the spectrometer and using an internal standard constituted of single crystals of CuSO 4 .5H 2 O. As the amplitude of the EPR signal is sensitive to the measurement temperature, a method of normalization of the results to 20 C has been determined. We have studied the influence of an irradiation parameter and of environmental parameters. We have shown that the EPR signal amplitude increases with irradiation temperature. The EPR signal amplitude and its evolution vary strongly with storage conditions (temperature and moisture) of the dosimeter before and after irradiation. The presence of moisture in alanine powder leads to a loss of signal amplitude. The dosimeters exposition to light also entails a loss of amplitude. Oxygen does not influence the EPR spectrum of alanine. We have noticed that the EPR signal amplitude of samples stored in absence of moisture

  11. Non-invasive determination of the irradiation dose in fingers using low-frequency EPR

    International Nuclear Information System (INIS)

    Zdravkova, M; Crokart, N; Trompier, F; Beghein, N; Gallez, B; Debuyst, R

    2004-01-01

    Several reports in the literature have described the effects of radiation in workers who exposed their fingers to intense radioactive sources. The radiation injuries occurring after local exposure to a high dose (20 to 100 Gy) could lead to the need for amputation. Follow-up of victims needs to be more rational with a precise knowledge of the irradiated area that risks tissue degradation and necrosis. It has been described previously that X-band electron paramagnetic resonance (EPR) spectroscopy could be used to assess the dose in irradiated amputated fingers. Here, we propose the use of low-frequency EPR spectroscopy to evaluate non-invasively the absorbed dose. Low-frequency microwaves are indeed less absorbed by water and penetrate more deeply into living material (∼10 mm in tissues using 1 GHz spectrometers). This work presents preliminary results obtained with baboon and human fingers compared with human dry phalanxes placed inside a surface-coil resonator. The EPR signal increased linearly with the dose. The ratio of the slopes of the dry bone to whole finger linear regression lines was around 5. The detection limit achievable with the present spectrometer and resonator is around 60 Gy, which is well within the range of accidentally exposed fingers. It is likely that the detection limit could be improved in the future, thanks to further technical spectrometer and resonator developments as well as to appropriate spectrum deconvolution into native and dosimetric signals

  12. In vivo and ex vivo EPR detection of spin-labelled ovalbumin in mice.

    Science.gov (United States)

    Abramović, Zrinka; Brgles, Marija; Habjanec, Lidija; Tomasić, Jelka; Sentjurc, Marjeta; Frkanec, Ruza

    2010-10-01

    In this study, spin-labelled ovalbumin (SL-OVA), free or entrapped in liposomes, was administered to mice subcutaneously (s.c.) or intravenously (i.v.) with the aim to determine the conditions for pharmacokinetic studies of spin-labelled proteins by EPR and to measure the time course of SL-OVA distribution in vivo in live mice and ex vivo in isolated organs. Upon s.c. administration, the decay of the EPR signal was followed for 60min at the site of application using an L-band EPR spectrometer. Within this time period, the signal of free SL-OVA was diminished by about 70%. It was estimated with the help of the oxidizing agent K(3)[(FeCN)(6)] that approximately 30% was a consequence of the spin label reduction to EPR non-visible hydroxylamine and about 40% was due to the SL-OVA elimination from the site of measurement. For liposome encapsulated SL-OVA, the intensity diminished only by approx. 40% in the same period, indicating that liposomes successfully protect the protein from reduction. EPR signal could not be detected directly over live mouse organs within 60min after s.c. application of SL-OVA. With the available L-band EPR spectrometer, the measurements at the site of s.c. application are possible if the amount of SL-OVA applied to a mouse is more than 3mg. For the pharmacokinetic studies of the protein distribution in organs after s.c. or i.v. injection the concentration of the spin-labelled protein should be more than 0.5mmol/kg. After i.v. administration, only ex vivo measurements were possible using an X-band EPR spectrometer, since the total amount of SL-OVA was not sufficient for in vivo detection and also because of rapid reduction of nitroxide. After 2min, the protein was preferentially distributed to liver and, to a smaller extent, to spleen.

  13. Evaluation of the ROTAX spectrometer

    International Nuclear Information System (INIS)

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  14. Some physico-technical aspects of the new generation of self-calibrated alanine/EPR dosimeter and results from the international intercomparison trial

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Gancheva, V.

    2000-01-01

    Some physico-technical parameters of the self-calibrated alanine/EPR dosimeters are described. Principally, this new type of solid state/EPR dosimeter contains radiation sensitive diamagnetic material (in the present case, alanine), some quantity of EPR active, but radiation insensitive, substance (for example, Mn 2+ /MgO) playing roles of an internal standard and a binding material. Thus with this dosimeter the EPR spectra of alanine and the internal standard Mn 2+ are recorded simultaneously and the dose response is represented as a ratio of EPR signal intensities of alanine versus Mn 2+ as a function of absorbed dose. As a result, the data of the present study have shown that there is practically no interference of the dosimeter EPR response (expressed as the ratio I alanine /I Mn ) from the way of preparation (homogeneity), behavior after irradiation (fading of EPR signals with time, influence of different meteorological conditions) as well as specific spectrometer setting conditions. These dosimeters show satisfactory reproducibility of preparation and reading as well as stability on keeping. Thus, fulfilling the described physico-technical data of this type of dosimeters, the reproducibility of the readings is significantly improved particularly when intercomparison among different laboratories is performed. This conclusion is confirmed by independent studies of the described self-calibrated alanine/EPR dosimeters in several laboratories in Europe. Results of which are also reported. (author)

  15. EPR project construction cost control

    International Nuclear Information System (INIS)

    Duflo, D.; Pouget-Abadie, X.; Dufour, A.; Kauffmann, G.

    2001-01-01

    The EPR project is now managed by EDF in cooperation with the German Utilities. The main engineering activities for this period are related to the preparation of construction project management, deepening of some safety issues, definition of the project technical reference. The EPR project concerns the so-called reference unit, that is an isolated first-off unit, with unit electrical power of about 1500 MW. The construction costs evaluated are those of the nuclear island, the conventional island, site facilities, installation work and the administrative buildings. The EPR project construction cost evaluation method applies to all the equipment installed and commissioned. It requires the availability of a preliminary project detailed enough to identify the bill of quantities. To these quantities are then assigned updated unit prices that are based either on cost bases for similar and recent facilities or taken from request for quotation for similar equipment or result from gains due to contractual conditions benefiting from simplifications in the functional and technical specifications. The input and output data are managed in a model that respects the breakdown on which the evaluation method is based. The structural organization of this method reflects a functional breakdown on the one hand (nuclear island, conventional island, common site elements) and on the other hand a breakdown according to equipment or activity (civil engineering, mechanics, electricity, instrumentation and control). This paper discusses the principle and the method of construction cost evaluation carried out, the cost data base and input and output parameters as well as results and oncoming cost analysis tasks. (author)

  16. EPR Dosimetry in Irradiated Fingernails

    International Nuclear Information System (INIS)

    Spinella, M.R.; Dubner, D.L.; Bof, E.

    2010-01-01

    The Electron Paramagnetic Resonance (EPR) is being transformed in a complementary tool of biologically-based methods for evaluation of dose after accidental radiation exposure. Many efforts are being carried out in laboratories to evaluate the performance of different materials for its use in EPR doses measurements and for improving the current methods for spectrum analysis and calibration curves determinations. In our country the EPR techniques have been used in different areas with dosimetric (alanine) and non dosimetric purposes. Now we are performing the first studies to obtain properly dose response curves to be used for accidental dose assessments through irradiated fingernails. It is by now well known that the fingernails present two types of signals, a background one (BKS), originated in elastic and inelastic mechanical deformations and the radio induced one (RIS), object of interest (I). In this work we will present some of the previous studies performed to characterize the fingernail samples and we analyse the additive dose method for data obtained employing the technique of the substraction of the spectrum recorded at two different microwave powers in order to reduce the BKS signal. Fingernail samples collected from different donors were treated by soaking in water during 10 min and 5 min drying on paper towel and the BKS signals were studied previously its irradiation. The statistical analysis (R statistics) show a distribution with a Standard Deviation of 24% respects to its media. During these studies we also conserved in freezer for more than 6 months irradiated fingernails that, were periodically measured and the statistical analysis of the peak to peak amplitude show a normal distribution through the Quantile correlation test with a SD 11% respected to its median. (authors)

  17. EPR of exchange coupled systems

    CERN Document Server

    Bencini, Alessandro

    2012-01-01

    From chemistry to solid state physics to biology, the applications of Electron Paramagnetic Resonance (EPR) are relevant to many areas. This unified treatment is based on the spin Hamiltonian approach and makes extensive use of irreducible tensor techniques to analyze systems in which two or more spins are magnetically coupled. This edition contains a new Introduction by coauthor Dante Gatteschi, a pioneer and scholar of molecular magnetism.The first two chapters review the foundations of exchange interactions, followed by examinations of the spectra of pairs and clusters, relaxation in oligon

  18. EPR investigations on technetium compounds

    International Nuclear Information System (INIS)

    Abram, U.; Munze, R.; Kirmse, R.; Stach, J.

    1986-01-01

    Stimulated by the widespread use of the isotope /sup 99m/Tc in the field of nuclear medicine, there has been a substantial growth of interest in the chemistry of this man-made element. A particular need emerges for analytical methods allowing solution investigations of coordination compounds of technetium with low substance use. Considering these facts, Electron Paramagnetic Resonance Spectroscopy (EPR) appears to be a very suitable method because only very small amounts of the compounds are needed (lower than 1 mg). The resulting spectra give information regarding the valence state, symmetry and bonding properties of the compounds under study

  19. EPR spectroscopic investigation of psoriatic finger nails.

    Science.gov (United States)

    Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke

    2013-11-01

    Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    Science.gov (United States)

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  1. Overview of LBB implementation for the EPR

    International Nuclear Information System (INIS)

    Cauquelin, C.

    1997-01-01

    This paper presents an overview of the use of leak-before-break (LBB) analysis for EPR reactors. EPR is an evolutionary Nuclear Island of the 4 loop x 1500 Mwe class currently in the design phase. Application of LBB to the main coolant lines and resulting design impacts are summarized. Background information on LBB analysis in France and Germany is also presented

  2. Overview of LBB implementation for the EPR

    Energy Technology Data Exchange (ETDEWEB)

    Cauquelin, C.

    1997-04-01

    This paper presents an overview of the use of leak-before-break (LBB) analysis for EPR reactors. EPR is an evolutionary Nuclear Island of the 4 loop x 1500 Mwe class currently in the design phase. Application of LBB to the main coolant lines and resulting design impacts are summarized. Background information on LBB analysis in France and Germany is also presented.

  3. EPR dosimetry with tooth enamel: A review

    International Nuclear Information System (INIS)

    Fattibene, Paola; Callens, Freddy

    2010-01-01

    When tooth enamel is exposed to ionizing radiation, radicals are formed, which can be detected using electron paramagnetic resonance (EPR) techniques. EPR dosimetry using tooth enamel is based on the (presumed) correlation between the intensity or amplitude of some of the radiation-induced signals with the dose absorbed in the enamel. In the present paper a critical review is given of this widely applied dosimetric method. The first part of the paper is fairly fundamental and deals with the main properties of tooth enamel and some of its model systems (e.g., synthetic apatites). Considerable attention is also paid to the numerous radiation-induced and native EPR signals and the radicals responsible for them. The relevant methods for EPR detection, identification and spectrum analyzing are reviewed from a general point of view. Finally, the needs for solid-state modelling and studies of the linearity of the dose response are investigated. The second part is devoted to the practical implementation of EPR dosimetry using enamel. It concerns specific problems of preparation of samples, their irradiation and spectrum acquisition. It also describes how the dosimetric signal intensity and dose can be retrieved from the EPR spectra. Special attention is paid to the energy dependence of the EPR response and to sources of uncertainties. Results of and problems encountered in international intercomparisons and epidemiological studies are also dealt with. In the final section the future of EPR dosimetry with tooth enamel is analyzed.

  4. EPR meeting international safety standards with margin

    International Nuclear Information System (INIS)

    Mazurkiewicz, S.M.; Brauns, J.; Blombach, J.

    2005-01-01

    The EPR provides technology that offers a solution to the market's need for safe, economic power. The EPR was originally developed through a joint effort between Framatome ANP and Siemens by incorporating the best technological features from the French and German nuclear reactor fleets into a cost-competitive product capable of international licensing. As such, the EPR is a global product with commercial units currently being built in Finland at the Olkiluoto site, and planned for France, at the Flamanville site. Framatome ANP has recently proposed four EPR units to China in response to a request for vendor bids. In addition, Framatome ANP has announced their intent to pursue design certification with the United States Nuclear Regulatory Commission (NRC). This paper discusses how EPR's innovative safety philosophy ensures compliance with international safety standards for advanced light-water reactors (ALWRs). (author)

  5. EPR meeting international safety standards with margin

    International Nuclear Information System (INIS)

    Mazurkiewicz, S.M.; Brauns, J.; Blombach, J.

    2005-01-01

    The EPR provides technology that offers a solution to the market's need for safe, economic power. The EPR was originally developed through a joint effort between Framatome ANP and Siemens by incorporating the best technological features from the French and German nuclear reactor fleets into a cost-competitive product capable of international licensing. As such, the EPR is a global product with commercial units currently being built in Finland at the Olkiluoto site, and planned for France, at the Flamanville site. Framatome ANP has recently proposed four EPR units to China in response to a request for vendor bids. In addition, Framatome ANP has announced their intent to pursue design certification in with the United States Nuclear Regulatory Commission (NRC). This paper discusses how EPR's innovative safety philosophy ensures compliance with international safety standards for advanced light-water reactors (ALWRs). (author)

  6. Isolation of EPR spectra and estimation of spin-states in two-component mixtures of paramagnets.

    Science.gov (United States)

    Chabbra, Sonia; Smith, David M; Bode, Bela E

    2018-04-26

    The presence of multiple paramagnetic species can lead to overlapping electron paramagnetic resonance (EPR) signals. This complication can be a critical obstacle for the use of EPR to unravel mechanisms and aid the understanding of earth abundant metal catalysis. Furthermore, redox or spin-crossover processes can result in the simultaneous presence of metal centres in different oxidation or spin states. In this contribution, pulse EPR experiments on model systems containing discrete mixtures of Cr(i) and Cr(iii) or Cu(ii) and Mn(ii) complexes demonstrate the feasibility of the separation of the EPR spectra of these species by inversion recovery filters and the identification of the relevant spin states by transient nutation experiments. We demonstrate the isolation of component spectra and identification of spin states in a mixture of catalyst precursors. The usefulness of the approach is emphasised by monitoring the fate of the chromium species upon activation of an industrially used precatalyst system.

  7. EPR dosimetry - present and future

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as co-ordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as biomarkers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (ASTM), and the International Organisation of Standards (ISO) as well as those of the International Commission on Radiation Units and Measurements (ICRU) considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (author)

  8. EPR Dosimetry - Present and Future

    Energy Technology Data Exchange (ETDEWEB)

    Regulla, D.F. [GSF - National Research Centre for Environment and Health, Institute of Radiation Protection, 85764 Neuherberg (Germany)

    1999-07-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  9. EPR Dosimetry - Present and Future

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1999-01-01

    In the past, IAEA has played a central role in stipulating research and development in EPR high-dose standardisation as well as in coordinating and organising international dose intercomparison programs, within the Member States of the United Nations from the mid-seventies till today. The future tasks of EPR dosimetry seem to tend towards different subjects such as bio markers, biological radiation effects, post-accident dose reconstruction in the environment, and retrospective human dosimetry. The latter may be considered a promising tool for epidemiology on the way to re-define radiation risk of man for chronicle radiation exposures, based on e.g. South Ural civil population and radiation workers. There are on-going international activities in the field of standardising high-level dosimetry by the American Standards on Testing and Materials (Astm), and by the International Organisation of Standards (ISO). The International Commission on Radiation Units and Measurements (ICRU) is considering the establishment of relevant recommendations concerning industrial radiation processing, but also human dose reconstruction. (Author)

  10. Small angle spectrometers: Summary

    International Nuclear Information System (INIS)

    Courant, E.; Foley, K.J.; Schlein, P.E.

    1986-01-01

    Aspects of experiments at small angles at the Superconducting Super Collider are considered. Topics summarized include a small angle spectrometer, a high contingency spectrometer, dipole and toroid spectrometers, and magnet choices

  11. Smartphone Spectrometers

    Science.gov (United States)

    Willmott, Jon R.; Mims, Forrest M.; Parisi, Alfio V.

    2018-01-01

    Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades. PMID:29342899

  12. Smartphone Spectrometers

    Directory of Open Access Journals (Sweden)

    Andrew J.S. McGonigle

    2018-01-01

    Full Text Available Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a ‘lab in a phone’ capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.

  13. EPR of free radicals in solids II trends in methods and applications

    CERN Document Server

    Lund, Anders; Lund, Anders

    2012-01-01

    EPR of Free Radicals in Solids: Trends in Methods and Applications, 2nd ed. presents a critical two volume review of the methods and applications of EPR (ESR) for the study of free radical processes in solids. Emphasis is on the progress made in the developments in EPR technology, in the application of sophisticated matrix isolation techniques and in the advancement in quantitative EPR that have occurred since the 1st edition was published. Improvements have been made also at theoretical level, with the development of methods based on first principles and their application to the calculation of magnetic properties as well as in spectral simulations. EPR of Free Radicals in Solids II focuses on the trends in applications of experimental and theoretical methods to extract structural and dynamical properties of radicals and spin probes in solid matrices by continuous wave (CW) and pulsed techniques in nine chapters written by experts in the field. It examines the studies involving radiation- and photo-induced in...

  14. EPR spectrum deconvolution and dose assessment of fossil tooth enamel using maximum likelihood common factor analysis

    International Nuclear Information System (INIS)

    Vanhaelewyn, G.; Callens, F.; Gruen, R.

    2000-01-01

    In order to determine the components which give rise to the EPR spectrum around g = 2 we have applied Maximum Likelihood Common Factor Analysis (MLCFA) on the EPR spectra of enamel sample 1126 which has previously been analysed by continuous wave and pulsed EPR as well as EPR microscopy. MLCFA yielded agreeing results on three sets of X-band spectra and the following components were identified: an orthorhombic component attributed to CO - 2 , an axial component CO 3- 3 , as well as four isotropic components, three of which could be attributed to SO - 2 , a tumbling CO - 2 and a central line of a dimethyl radical. The X-band results were confirmed by analysis of Q-band spectra where three additional isotropic lines were found, however, these three components could not be attributed to known radicals. The orthorhombic component was used to establish dose response curves for the assessment of the past radiation dose, D E . The results appear to be more reliable than those based on conventional peak-to-peak EPR intensity measurements or simple Gaussian deconvolution methods

  15. Detection of Redox Imbalance in Normal Lymphocytes with Induced Mitochondrial Dysfunction - EPR Study.

    Science.gov (United States)

    Georgieva, Ekaterina; Zhelev, Zhivko; Aoki, Ichio; Bakalova, Rumiana; Higashi, Tatsuya

    2016-10-01

    The present study describes a new approach for direct imaging of redox status in live cells using paramagnetic spin-probes, which allows evaluation of the level of oxidative stress due to overproduction of superoxide. The method is based on redox cycling of cell/mitochondria-penetrating nitroxide radicals (e.g. mito-TEMPO) and their electron-paramagnetic resonance (EPR) contrast, which makes them useful molecular sensors for analysis of redox status and oxidative stress in cells and tissues. Oxidative stress was induced in normal human lymphocytes by treatment with 2-methoxyestradiol and rotenone (ME/Rot) at different concentrations. This combination provokes mitochondrial dysfunction, which is accompanied by overproduction of superoxide. The EPR measurements were performed in dynamics on X-Band spectrometer after addition of mito-TEMPO to cell suspensions. The intensity of the EPR signal in untreated cells decreased significantly, which indicates a conversion of paramagnetic mito-TEMPO to its non-contrast diamagnetic form (hydroxylamine - mito-TEMPOH) due to reduction. In ME/Rot-treated cells, the signal decreased more slowly and to a lower level with increasing the concentration of ME/Rot. These data indicate an induction of oxidative stress in the cells in a concentration-dependent manner. A very good positive correlation between the intensity of EPR signal of mito-TEMPO and the intracellular level of superoxide was found, analyzed by conventional dihydroethidium test (R=0.9143, pEPR imaging of the superoxide level in live cells, as well as for EPR imaging of mitochondrial dysfunction and metabolic activity, accompanied by superoxide imbalance. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  16. EPR invastigation of glasses on the base of the oxides of vanadium and tellurium

    International Nuclear Information System (INIS)

    Imanov, L.M; Ibragimov, Z.A.

    1978-01-01

    The results of investigation of EPR spectra of the nV 2 O 5 (100-n)TeO 2 binary system in the range from 95 to 5 mol % V 2 O 5 with the 5 mol % step on the DRON-2 installation (X-ray diffraction measurements) are presented. The EPR spectra were read out on the RE-1301 spectrometer at liquid nitrogen and room temperatures. The concentration of the EPR centres was determined by comparing it with the signal from the known number of Cu 2+ ions in the CuSO 4 x5H 2 O crystal. It is established that the VO 2+ complexes were the EPR centres. In all prepared samples the EPR spectra were observed, and at n=70 the SFS components were revealed both in the crystalline (with the TeO 2 content up to 30 mol %) and in amorphous states. The singularities of the EPR spectrum are discussed on the basis of the spin-hamiltonian with axial asymmetry. The dependence of the spin-hamiltonian components on the content was revealed and the P=670 value characterizing the average value of the distance between the nucleus and noncoupled electron is found. Observation of the line with well resoluted SFS components in the amorphous samples is explained by 'a great freedom'' of paramagnetic ions in the choice of close environment, and consequently the field of ligand atoms localizing in the paramagnetic ion produces the ''strong field'' effect (D, E>>GβH, G=1.985+-0.005) and removes degeneration due to the presence of the I=7/2 nuclear momentum of the V 4+ ion. Conservation of the SFS lines even at room temperature is connected with great scattering of the spin-lattice relaxation time

  17. A novel microfluidic rapid freeze-quench device for trapping reactions intermediates for high field EPR analysis.

    Science.gov (United States)

    Kaufmann, Royi; Yadid, Itamar; Goldfarb, Daniella

    2013-05-01

    Rapid freeze quench electron paramagnetic resonance (RFQ)-EPR is a method for trapping short lived intermediates in chemical reactions and subjecting them to EPR spectroscopy investigation for their characterization. Two (or more) reacting components are mixed at room temperature and after some delay the mixture is sprayed into a cold trap and transferred into the EPR tube. A major caveat in using commercial RFQ-EPR for high field EPR applications is the relatively large amount of sample needed for each time point, a major part of which is wasted as the dead volume of the instrument. The small sample volume (∼2μl) needed for high field EPR spectrometers, such as W-band (∼3.5T, 95GHz), that use cavities calls for the development of a microfluidic based RFQ-EPR apparatus. This is particularly important for biological applications because of the difficulties often encountered in producing large amounts of intrinsically paramagnetic proteins and spin labeled nucleic acid and proteins. Here we describe a dedicated microfluidic based RFQ-EPR apparatus suitable for small volume samples in the range of a few μl. The device is based on a previously published microfluidic mixer and features a new ejection mechanism and a novel cold trap that allows collection of a series of different time points in one continuous experiment. The reduction of a nitroxide radical with dithionite, employing the signal of Mn(2+) as an internal standard was used to demonstrate the performance of the microfluidic RFQ apparatus. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Shape effect in FMR of Ni-Co-Mn-In layers obtained by pulsed laser deposition

    Directory of Open Access Journals (Sweden)

    Dubiel Łukasz

    2017-01-01

    Full Text Available We have studied thin layers of Ni50-xCoxMn50-yIny alloys on (001 Si substrate obtained by pulsed laser deposition method (PLD using YAG Nd3+ laser operating at second harmonic. The target was bulk Ni50-xCoxMn50-yIny (x = 5, y = 14.5 alloy prepared by induction melting of pure elements under argon atmosphere. Magnetic properties were investigated on Bruker X band EPR spectrometer (9.36 GHz at room temperature. The magnetic resonance spectrum consists of non-symmetric lines with resonance field within wide field range (2500-4800 Gs depending on the orientation of the static field in the plane perpendicular to the layer. Calculated spectroscopic splitting factor g = 2.09.

  19. Thermal induced EPR signals in tooth enamel

    International Nuclear Information System (INIS)

    Fattibene, P.; Aragno, D.; Onori, S.; Pressello, M.C.

    2000-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used to detect the effects of temperature on powdered human tooth enamel, not irradiated in the laboratory. Samples were heated at temperature between 350 and 450, at 600 and at 1000 deg. C, for different heating times, between 6 min and 39 h. Changes in the EPR spectra were detected, with the formation of new signals. Possible correlation between the changes in EPR spectra and modifications in the enamel and in the mineral phase of bone detected with other techniques is discussed. The implications for dosimetric applications of signals induced by overheating due to mechanical friction during sample preparation are underlined

  20. Nitrosyl hemoglobins: EPR above 80 K

    Energy Technology Data Exchange (ETDEWEB)

    Wajnberg, E.; Bemski, G.; El-Jaick, L.J.; Alves, O.C.

    1995-03-01

    The EPR spectra of nitrosyl hemoglobin and myoglobin in different conditions (native, denatured and lyophilized), as well as of hematin-NO were obtained in the temperature range of 80 K-280 K. There is a substantial and reversible.decrease of the areas of the EPR spectra of all the hemoglobin samples above 150 K. The interpretation of the results implies the existence of two conformational states in thermal equilibrium only one of which is EPR detectable. Thermodynamical parameters are determined for the hexa and penta-coordinated cases. (author). 25 refs, 3 figs.

  1. Nitrosyl hemoglobins: EPR above 80 K

    International Nuclear Information System (INIS)

    Wajnberg, E.; Bemski, G.; El-Jaick, L.J.; Alves, O.C.

    1995-03-01

    The EPR spectra of nitrosyl hemoglobin and myoglobin in different conditions (native, denatured and lyophilized), as well as of hematin-NO were obtained in the temperature range of 80 K-280 K. There is a substantial and reversible.decrease of the areas of the EPR spectra of all the hemoglobin samples above 150 K. The interpretation of the results implies the existence of two conformational states in thermal equilibrium only one of which is EPR detectable. Thermodynamical parameters are determined for the hexa and penta-coordinated cases. (author). 25 refs, 3 figs

  2. EPR spectroscopy as a potential approach to identify irradiated food and radiation dosimetry - an overview

    International Nuclear Information System (INIS)

    Sanyal, Bhaskar; Chawla, S.P.

    2017-01-01

    The need for reliable and routine tests to determine whether or not food has been irradiated has arisen as a result of the progress made in commercialization of the food irradiation technology. The effectiveness of food irradiation depends on proper delivery of absorbed dose and its reliable measurement. Electron Paramagnetic Resonance (EPR) spectroscopy has been established as an essential tool both for detection of irradiated food and radiation measurements. This presentation demonstrates the behavior of the radicals produced in irradiated cashew nut and orange. In addition the role of EPR spectroscopy will be discussed to understand thermoluminescence behavior of CaSO 4 dosimeter. Cashew nut and orange samples were exposed to gamma radiation in the dose range of 0.25 to 2 kGy. CaSO 4 crystals were irradiated at 0.5-7 kGy. Electron Paramagnetic Resonance (EPR) spectroscopy was carried out using EMX model EPR spectrometer (BRUKER, Germany) with a microwave frequency of 9.42 GHz

  3. Homogeneity and EPR metrics for assessment of regular grids used in CW EPR powder simulations.

    Science.gov (United States)

    Crăciun, Cora

    2014-08-01

    CW EPR powder spectra may be approximated numerically using a spherical grid and a Voronoi tessellation-based cubature. For a given spin system, the quality of simulated EPR spectra depends on the grid type, size, and orientation in the molecular frame. In previous work, the grids used in CW EPR powder simulations have been compared mainly from geometric perspective. However, some grids with similar homogeneity degree generate different quality simulated spectra. This paper evaluates the grids from EPR perspective, by defining two metrics depending on the spin system characteristics and the grid Voronoi tessellation. The first metric determines if the grid points are EPR-centred in their Voronoi cells, based on the resonance magnetic field variations inside these cells. The second metric verifies if the adjacent Voronoi cells of the tessellation are EPR-overlapping, by computing the common range of their resonance magnetic field intervals. Beside a series of well known regular grids, the paper investigates a modified ZCW grid and a Fibonacci spherical code, which are new in the context of EPR simulations. For the investigated grids, the EPR metrics bring more information than the homogeneity quantities and are better related to the grids' EPR behaviour, for different spin system symmetries. The metrics' efficiency and limits are finally verified for grids generated from the initial ones, by using the original or magnetic field-constraint variants of the Spherical Centroidal Voronoi Tessellation method. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Homogeneity and EPR metrics for assessment of regular grids used in CW EPR powder simulations

    Science.gov (United States)

    Crăciun, Cora

    2014-08-01

    CW EPR powder spectra may be approximated numerically using a spherical grid and a Voronoi tessellation-based cubature. For a given spin system, the quality of simulated EPR spectra depends on the grid type, size, and orientation in the molecular frame. In previous work, the grids used in CW EPR powder simulations have been compared mainly from geometric perspective. However, some grids with similar homogeneity degree generate different quality simulated spectra. This paper evaluates the grids from EPR perspective, by defining two metrics depending on the spin system characteristics and the grid Voronoi tessellation. The first metric determines if the grid points are EPR-centred in their Voronoi cells, based on the resonance magnetic field variations inside these cells. The second metric verifies if the adjacent Voronoi cells of the tessellation are EPR-overlapping, by computing the common range of their resonance magnetic field intervals. Beside a series of well known regular grids, the paper investigates a modified ZCW grid and a Fibonacci spherical code, which are new in the context of EPR simulations. For the investigated grids, the EPR metrics bring more information than the homogeneity quantities and are better related to the grids’ EPR behaviour, for different spin system symmetries. The metrics’ efficiency and limits are finally verified for grids generated from the initial ones, by using the original or magnetic field-constraint variants of the Spherical Centroidal Voronoi Tessellation method.

  5. New loophole for the EPR paradox

    OpenAIRE

    Feldmann, Michel

    1999-01-01

    We exhibit a classical model free from any paradox which exactly simulates the spin EPR test. We conclude that Bell's inequality violation is a strictly classical phenomenon, contrary to a general belief.

  6. High-field EPR on membrane proteins - crossing the gap to NMR.

    Science.gov (United States)

    Möbius, Klaus; Lubitz, Wolfgang; Savitsky, Anton

    2013-11-01

    In this review on advanced EPR spectroscopy, which addresses both the EPR and NMR communities, considerable emphasis is put on delineating the complementarity of NMR and EPR concerning the measurement of molecular interactions in large biomolecules. From these interactions, detailed information can be revealed on structure and dynamics of macromolecules embedded in solution- or solid-state environments. New developments in pulsed microwave and sweepable cryomagnet technology as well as ultrafast electronics for signal data handling and processing have pushed to new horizons the limits of EPR spectroscopy and its multifrequency extensions concerning the sensitivity of detection, the selectivity with respect to interactions, and the resolution in frequency and time domains. One of the most important advances has been the extension of EPR to high magnetic fields and microwave frequencies, very much in analogy to what happens in NMR. This is exemplified by referring to ongoing efforts for signal enhancement in both NMR and EPR double-resonance techniques by exploiting dynamic nuclear or electron spin polarization via unpaired electron spins and their electron-nuclear or electron-electron interactions. Signal and resolution enhancements are particularly spectacular for double-resonance techniques such as ENDOR and PELDOR at high magnetic fields. They provide greatly improved orientational selection for disordered samples that approaches single-crystal resolution at canonical g-tensor orientations - even for molecules with small g-anisotropies. Exchange of experience between the EPR and NMR communities allows for handling polarization and resolution improvement strategies in an optimal manner. Consequently, a dramatic improvement of EPR detection sensitivity could be achieved, even for short-lived paramagnetic reaction intermediates. Unique structural and dynamic information is thus revealed that can hardly be obtained by any other analytical techniques. Micromolar

  7. EFFECT OF CADMIUM(II) ON FREE RADICALS IN DOPA-MELANIN TESTED BY EPR SPECTROSCOPY.

    Science.gov (United States)

    Zdybel, Magdalena; Pilawa, Barbara; Chodurek, Ewa

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy may be applied to examine interactions of melanin with metal ions and drugs. In this work EPR method was used to examination of changes in free radical system of DOPA-melanin--the model eumelanin after complexing with diamagnetic cadmium(II) ions. Cadmium(II) may affect free radicals in melanin and drugs binding by this polymer, so the knowledge of modification of properties and free radical concentration in melanin is important to pharmacy. The effect of cadmium(II) in different concentrations on free radicals in DOPA-melanin was determined. EPR spectra of DOPA-melanin, and DOPA-melanin complexes with cadmium(II) were measured by an X-band (9.3 GHz) EPR spectrometer produced by Radiopan (Poznań, Poland) and the Rapid Scan Unit from Jagmar (Krak6w, Poland). The DOPA (3,4-dihydroxyphenylalanine) to metal ions molar ratios in the reaction mixtures were 2:1, 1:1, and 1: 2. High concentrations of o-semiquinone (g ~2.0040) free radicals (~10(21)-10(22) spin/g) characterize DOPA-melanin and its complexes with cadmium(II). Formation of melanin complexes with cadmium(II) increase free radical concentration in DOPA-melanin. The highest free radical concentration was obtained for DOPA-melanin-cadmium(II) (1:1) complexes. Broad EPR lines with linewidths: 0.37-0.73 mT, were measured. Linewidths increase after binding of cadmium(II) to melanin. Changes of integral intensities and linewidths with increasing microwave power indicate the homogeneous broadening of EPR lines, independently on the metal ion concentration. Slow spin-lattice relaxation processes existed in all the tested samples, their EPR lines saturated at low microwave powers. Cadmium(II) causes fastening of spin-lattice relaxation processes in DOPA-melanin. The EPR results bring to light the effect of cadmium(II) on free radicals in melanin, and probably as the consequence on drug binding to eumelanin.

  8. Spin entanglement, decoherence and Bohm's EPR paradox

    OpenAIRE

    Cavalcanti, E. G.; Drummond, P. D.; Bachor, H. A.; Reid, M. D.

    2007-01-01

    We obtain criteria for entanglement and the EPR paradox for spin-entangled particles and analyse the effects of decoherence caused by absorption and state purity errors. For a two qubit photonic state, entanglement can occur for all transmission efficiencies. In this case, the state preparation purity must be above a threshold value. However, Bohm's spin EPR paradox can be achieved only above a critical level of loss. We calculate a required efficiency of 58%, which appears achievable with cu...

  9. Applications of EPR in radiation research

    CERN Document Server

    Lund, Anders

    2014-01-01

    Applications of EPR in Radiation Research is a multi-author contributed volume presented in eight themes: I. Elementary radiation processes (in situ and low temperature radiolysis, quantum solids); II: Solid state radiation chemistry (crystalline, amorphous and heterogeneous systems); III: Biochemistry, biophysics and biology applications (radicals in biomaterials, spin trapping, free-radical-induced DNA damage); IV: Materials science (polymeric and electronic materials, materials for treatment of nuclear waste, irradiated food); V: Radiation metrology (EPR-dosimetry, retrospective and medical

  10. EPR Spectroscopy in Environmental Lichen-Indication

    Science.gov (United States)

    Bondarenko, P. V.; Nguyet, Le Thi Bich; Zhuravleva, S. E.; Trukhan, E. M.

    2017-09-01

    The paramagnetic properties of lichens were investigated using EPR spectroscopy and Xanthoria parietina (L.) Th. Fr. as a case study. It was found that the concentration of paramagnetic centers in lichen thalli increased as the air-pollution level increased. Possible formation mechanisms of the paramagnetic centers in lichens were discussed. The efficiency of using EPR spectroscopy to study lichens as environmental quality indicators was demonstrated.

  11. EPR of alanine irradiated by neutrons

    International Nuclear Information System (INIS)

    Pivovarov, S.P.; Seredavina, T.A.; Zhdanov, S.V.; Mul'gin, S.I.; Zhakparov, R.K.

    2001-01-01

    In the work the first results of EPR studies of alanine, irradiated with diverse doses at neutron cyclotron generator different conditions and on the critical reactor stand are presented. A dose linearity dependence of EPR signal is observing, the methods of γ-background contribution separation are discussed. Obtain results is giving the basis to recommendation of alanine as an effective detector irradiation. However it is demanded the farther study on clarification of radiation sensitivity value dependence on the neutron energy spectrum form

  12. Some characteristics of a miniature neutron spectrometer

    International Nuclear Information System (INIS)

    Sekimoto, H.; Oishi, K.; Hojo, K.; Hojo, T.

    1984-01-01

    Some characteristics of an NE213 miniature spherical spectrometer for in-assembly fast-neutron spectrometry were measured. As the bubbling time changed, the pulse-height did not change appreciably, but the n-γ discrimination characteristics changed considerably. As the count rate changed, the pulse-height did not change appreciably, and the change of the n-γ discrimination characteristics was acceptable. The neutron response function was measured to be almost isotropic except for the backward direction. (orig.)

  13. EPR spectra of synthetic, and natural Australian opals - A pilot study

    International Nuclear Information System (INIS)

    Hutton, D.R.; Troup, G.J.

    1996-01-01

    Full text: The EPR spectra of some synthetic opals, and of some Australian natural opals of various provenance, have been obtained, with the use of a Varian E-12 EPR spectrometer operating at ∼9.2 Ghz. The synthetic opals, from Swiss Gilson showed here a broad ESR signal in the g =2 region, with little identifiable structure . The natural Australian opals from Coober Pedy, Lightning Ridge, and Mintabie all showed the clear presence of Fe 3+ , Mn 2+ and a free radical like signal, suspected to be localised on an Al atom. Examples of the various spectra will be presented. It is not yet certain how the spectra correlate with provenance, but the synthetic spectra are quite different from the natural ones

  14. Development of a new dosimeter of EPR based on lactose; Desarrollo de un nuevo dosimetro de RPE basado en lactosa

    Energy Technology Data Exchange (ETDEWEB)

    Cruz C, L.; Torijano C, E.; Azorin N, J.; Aguirre G, F. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Cruz Z, E., E-mail: eftc@xanum.uam.mx [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2014-08-15

    50 years have passed since was proposed using the amino acid alanine as dosimeter advantage the phenomenon of electron paramagnetic resonance (EPR); this dosimetric method has reached a highly competitive level regarding others dosimetry classic methods, for example the thermoluminescence or the use of Fricke dosimeters, to measure high dose of radiation. In this type of materials, the free radicals induced by the radiation are stable and their concentration is proportional to the absorbed dose may be determined by the amplitude pick to pick of the first derived of the EPR absorption spectrum. The obtained results studying the EPR response of lactose tablets elaborated in the Universidad Autonoma Metropolitana, Unidad Iztapalapa are presented. The tablets were irradiated with gamma radiation of {sup 60}Co in the irradiator Gamma beam 651-Pt of the Instituto de Ciencias Nucleares de la Universidad Nacional Autonoma de Mexico to a dose rate of 8 kGy-h{sup -1} and their EPR response in a EPR spectrometer e-scan Bruker. The obtained response in function of the dose was lineal in the interval of 1 at 10 kGy. The lactose sensibility was compared with the l-alanine, used as reference, and the result was consistently 0.25 of this. Due to the linearity shown in the interval of used dose and their low production cost, we conclude that the lactose is a promissory option for the dosimetry of high dose of radiation. (author)

  15. Tests of a prototype resonance filter spectrometer at WNR

    International Nuclear Information System (INIS)

    Newport, R.J.; Seeger, P.A.; Williams, W.G.

    1984-11-01

    Data gained during a series of developmental experiments using the SNS test resonance filter spectrometer at the WNR pulsed neutron facility, Los Alamos, are presented and discussed. The operational experience obtained during the period of these studies has provided some insight into the desirable characteristics and possible limitations of any future spectrometer design and this information is considered in some detail. (author)

  16. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  17. In vivo EPR extracellular pH-metry in tumors using a triphosphonated trityl radical.

    Science.gov (United States)

    Marchand, Valérie; Levêque, Philippe; Driesschaert, Benoit; Marchand-Brynaert, Jacqueline; Gallez, Bernard

    2017-06-01

    The ability to assess the extracellular pH (pHe) is an important issue in oncology, because extracellular acidification is associated with tumor aggressiveness and resistance to cytotoxic therapies. In this study, a stable triphosphonated triarylmethyl (TPTAM) radical was qualified as a pHe electron paramagnetic resonance (EPR) molecular reporter. Calibration of hyperfine splitting as a function of pH was performed using a 1.2-GHz EPR spectrometer. Gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) was used as an extracellular paramagnetic broadening agent to assess the localization of TPTAM when incubated with cells. In vivo EPR pH-metry was performed in MDA, SiHa, and TLT tumor models and in muscle. Bicarbonate therapy was used to modulate the tumor pHe. EPR measurements were compared with microelectrode readouts. The hyperfine splitting of TPTAM was strongly pH-dependent around the pKa of the probe (pKa = 6.99). Experiments with Gd-DTPA demonstrated that TPTAM remained in the extracellular compartment. pHe was found to be more acidic in the MDA, SiHa, and TLT tumor models compared with muscle. Treatment of animals by bicarbonate induced an increase in pHe in tumors: similar variations in pHe were found when using in vivo EPR or invasive microelectrodes measurements. This study demonstrates the potential usefulness of TPTAM for monitoring pHe in tumors. Magn Reson Med 77:2438-2443, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. EPR Dosimetry for ageing effect in NPP

    International Nuclear Information System (INIS)

    Choi, Hoon; Lim, Young Ki; Kim, Jong Seog; Jung, Sun Chul

    2005-01-01

    As one of the retrospective dosimetry method, EPR spectroscopy has been studied by many research up to theses days. As a dosimeter for EPR spectroscopy, Alanine is already a well known dosimeter in the field of radiation therapy and dose assessment in radiological accident by its characteristics as good linearity in a wide range of energy level and extremely low signal fading on time. Through technical document of IAEA, the EPR dosimetry method using alanine sample was published in 2000 after research by coordinated project on management of ageing of in-containment I and C cables. Although alanine sample is regarded as a good EPR dosimeter like above ageing assessment field, actually the assessment of radiation should be done at least for two fuel cycles, because of its relatively low irradiation environment in almost all spots in power plant. So, for getting more accurate detection value of radiation, another material is tested for being put in simultaneously inside the power plant with alanine. The test result for lithium formate monohydrate (HCO 2 LiH 2 0) was presented below for checking its possibility for being applied as EPR dosimeter for this project

  19. Characterization of KCNE1 inside Lipodisq Nanoparticles for EPR Spectroscopic Studies of Membrane Proteins.

    Science.gov (United States)

    Sahu, Indra D; Zhang, Rongfu; Dunagan, Megan M; Craig, Andrew F; Lorigan, Gary A

    2017-06-01

    EPR spectroscopic studies of membrane proteins in a physiologically relevant native membrane-bound state are extremely challenging due to the complexity observed in inhomogeneity sample preparation and dynamic motion of the spin-label. Traditionally, detergent micelles are the most widely used membrane mimetics for membrane proteins due to their smaller size and homogeneity, providing high-resolution structure analysis by solution NMR spectroscopy. However, it is often difficult to examine whether the protein structure in a micelle environment is the same as that of the respective membrane-bound state. Recently, lipodisq nanoparticles have been introduced as a potentially good membrane mimetic system for structural studies of membrane proteins. However, a detailed characterization of a spin-labeled membrane protein incorporated into lipodisq nanoparticles is still lacking. In this work, lipodisq nanoparticles were used as a membrane mimic system for probing the structural and dynamic properties of the integral membrane protein KCNE1 using site-directed spin labeling EPR spectroscopy. The characterization of spin-labeled KCNE1 incorporated into lipodisq nanoparticles was carried out using CW-EPR titration experiments for the EPR spectral line shape analysis and pulsed EPR titration experiment for the phase memory time (T m ) measurements. The CW-EPR titration experiment indicated an increase in spectral line broadening with the addition of the SMA polymer which approaches close to the rigid limit at a lipid to polymer weight ratio of 1:1, providing a clear solubilization of the protein-lipid complex. Similarly, the T m titration experiment indicated an increase in T m values with the addition of SMA polymer and approaches ∼2 μs at a lipid to polymer weight ratio of 1:2. Additionally, CW-EPR spectral line shape analysis was performed on six inside and six outside the membrane spin-label probes of KCNE1 in lipodisq nanoparticles. The results indicated significant

  20. How can EPR spectroscopy help to unravel molecular mechanisms of flavin-dependent photoreceptors?

    Directory of Open Access Journals (Sweden)

    Daniel eNohr

    2015-09-01

    Full Text Available Electron paramagnetic resonance (EPR spectroscopy is a well-established spectroscopic method for the examination of paramagnetic molecules. Proteins can contain paramagnetic moieties in form of stable cofactors, transiently formed intermediates, or spin labels artificially introduced to cysteine sites. The focus of this review is to evaluate potential scopes of application of EPR to the emerging field of optogenetics. The main objective for EPR spectroscopy in this context is to unravel the complex mechanisms of light-active proteins, from their primary photoreaction to downstream signal transduction. An overview of recent results from the family of flavin-containing, blue-light dependent photoreceptors is given. In detail, mechanistic similarities and differences are condensed from the three classes of flavoproteins, the cryptochromes, LOV (Light-oxygen-voltage, and BLUF (blue-light using FAD domains. Additionally, a concept that includes spin-labeled proteins and examination using modern pulsed EPR is introduced, which allows for a precise mapping of light-induced conformational changes.

  1. How can EPR spectroscopy help to unravel molecular mechanisms of flavin-dependent photoreceptors?

    Science.gov (United States)

    Nohr, Daniel; Rodriguez, Ryan; Weber, Stefan; Schleicher, Erik

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy is a well-established spectroscopic method for the examination of paramagnetic molecules. Proteins can contain paramagnetic moieties in form of stable cofactors, transiently formed intermediates, or spin labels artificially introduced to cysteine sites. The focus of this review is to evaluate potential scopes of application of EPR to the emerging field of optogenetics. The main objective for EPR spectroscopy in this context is to unravel the complex mechanisms of light-active proteins, from their primary photoreaction to downstream signal transduction. An overview of recent results from the family of flavin-containing, blue-light dependent photoreceptors is given. In detail, mechanistic similarities and differences are condensed from the three classes of flavoproteins, the cryptochromes, LOV (Light-oxygen-voltage), and BLUF (blue-light using FAD) domains. Additionally, a concept that includes spin-labeled proteins and examination using modern pulsed EPR is introduced, which allows for a precise mapping of light-induced conformational changes.

  2. Magnetic, catalytic, EPR and electrochemical studies on binuclear ...

    Indian Academy of Sciences (India)

    Magnetic, catalytic, EPR and electrochemical studies on binuclear copper(II) complexes ... to the oxidation of 3,5-di--butylcatechol to the corresponding quinone. ... EPR spectral studies in methanol solvent show welldefined four hyperfine ...

  3. Investigation of radical locations in various sesame seeds by CW EPR and 9-GHz EPR imaging.

    Science.gov (United States)

    Nakagawa, K; Hara, H

    2015-01-01

    We investigated the location of radical in various sesame seeds using continuous-wave (CW) electron paramagnetic resonance (EPR) and 9-GHz EPR imaging. CW EPR detected persistent radicals (single line) for various sesame seeds. The EPR linewidth of black sesame seeds was narrower than that of the irradiated white sesame seeds. A very small signal was detected for the white sesame seeds. Two-dimensional (2D) imaging using a 9-GHz EPR imager showed that radical locations vary for various sesame seeds. The paramagnetic species in black sesame seeds were located on the seed coat (skin) and in the hilum region. The signal with the highest intensity was obtained from the hilum part. A very low-intensity image was observed for the white sesame seeds. In addition, the 2D imaging of the irradiated white sesame seeds showed that free radicals were located throughout the entire seed. For the first time, CW EPR and 9-GHz EPR imaging showed the exact location of radical species in various sesame seeds.

  4. EPR study of N+-ion-induced free radical formation in antibiotic-producers

    International Nuclear Information System (INIS)

    Xie Liqing; Zhang Yinfen; Chen Ruyi; Gao Juncheng; Zhang Peiling; Ying Hengfeng.

    1995-01-01

    Under the room temperature, electron paramagnetic resonance (EPR) spectrometer was used to study free radical formation in antibiotic-producers in order to investigate antibiotic-producer mutagenic breeding, which were induced by N + ion implanting into antibiotic-producers (e.g., Streptomyces ribosidificus, Streptomyces kanamyceticus and the phage-resistant culture of Streptomyces kanamyceticus). The results show that a lot of free radicals can be induced by N + ion implanting into antibiotic-producers, and the yields of the free radicals increase with implanting dose. The death rate of antibiotic-producers rises due to the increase of N + -ion-induced free radical yields. (author)

  5. Computational and instrumental methods in EPR

    CERN Document Server

    Bender, Christopher J

    2006-01-01

    Computational and Instrumental Methods in EPR Prof. Bender, Fordham University Prof. Lawrence J. Berliner, University of Denver Electron magnetic resonance has been greatly facilitated by the introduction of advances in instrumentation and better computational tools, such as the increasingly widespread use of the density matrix formalism. This volume is devoted to both instrumentation and computation aspects of EPR, while addressing applications such as spin relaxation time measurements, the measurement of hyperfine interaction parameters, and the recovery of Mn(II) spin Hamiltonian parameters via spectral simulation. Key features: Microwave Amplitude Modulation Technique to Measure Spin-Lattice (T1) and Spin-Spin (T2) Relaxation Times Improvement in the Measurement of Spin-Lattice Relaxation Time in Electron Paramagnetic Resonance Quantitative Measurement of Magnetic Hyperfine Parameters and the Physical Organic Chemistry of Supramolecular Systems New Methods of Simulation of Mn(II) EPR Spectra: Single Cryst...

  6. EPR spectra of some irradiated polycrystalline perrhenate

    International Nuclear Information System (INIS)

    Zaitseva, N.G.; Constantinescu, M.; Georgescu, R.; Constantinescu, O.

    1978-10-01

    An EPR study of the paramagnetic centers formed by γ, electron and neutron irradiation of the NaReO 4 and KReO 4 was made. In the EPR spectra of the powder samples irradiated γ, with electrons and neutrons, the presence of three types of paramagnetic centers was observed. From the EPR parameters, the centers were attributed to the ReOsub(4)sup(.), ReOsub(3)sup(.) and ReOsub(2)sup(.) radicals respectively. The lower intensity of the spectra observed by KReO 4 samples irradiation showed a higher radioresistance of the KReO 4 than that of NaReO 4 . A radiolitical scheme taking into account the paramagnetic centers formation was proposed. (author)

  7. Relativistic Nonlocality and the EPR Paradox

    Science.gov (United States)

    Chamberlain, Thomas

    2014-03-01

    The exact violation of Bell's Inequalities is obtained with a local realistic model for spin. The model treats one particle that comprises a quantum ensemble and simulates the EPR data one coincidence at a time as a product state. Such a spin is represented by operators σx , iσy ,σz in its body frame rather than the usual set of σX ,σY ,σZ in the laboratory frame. This model, assumed valid in the absence of a measuring probe, contains both quantum polarizations and coherences. Each carries half the EPR correlation, but only half can be measured using coincidence techniques. The model further predicts the filter angles that maximize the spin correlation in EPR experiments.

  8. Pressurized water reactors: the EPR project

    International Nuclear Information System (INIS)

    Py, J.P.; Yvon, M.

    2007-01-01

    EPR (originally 'European pressurized water reactor', and now 'evolutionary power reactor') is a model of reactor initially jointly developed by French and German engineers which fulfills the particular safety specifications of both countries but also the European utility requirements jointly elaborated by the main European power companies under the initiative of Electricite de France (EdF). Today, two EPR-based reactors are under development: one is under construction in Finland and the other, Flamanville 3 (France), received its creation permit decree on April 10, 2007. This article presents, first, the main objectives of the EPR, and then, describes the Flamanville 3 reactor: reactor type and general conditions, core and conditions of operation, primary and secondary circuits with their components, main auxiliary and recovery systems, man-machine interface and instrumentation and control system, confinement and serious accidents, arrangement of buildings. (J.S.)

  9. Spin entanglement, decoherence and Bohm's EPR paradox.

    Science.gov (United States)

    Cavalcanti, E G; Drummond, P D; Bachor, H A; Reid, M D

    2009-10-12

    We obtain criteria for entanglement and the EPR paradox for spin-entangled particles and analyse the effects of decoherence caused by absorption and state purity errors. For a two qubit photonic state, entanglement can occur for all transmission efficiencies. In this case, the state preparation purity must be above a threshold value. However, Bohm's spin EPR paradox can be achieved only above a critical level of loss. We calculate a required efficiency of 58%, which appears achievable with current quantum optical technologies. For a macroscopic number of particles prepared in a correlated state, spin entanglement and the EPR paradox can be demonstrated using our criteria for efficiencies eta > 1/3 and eta > 2/3 respectively. This indicates a surprising insensitivity to loss decoherence, in a macroscopic system of ultra-cold atoms or photons.

  10. EPR and development of quantum electronics

    International Nuclear Information System (INIS)

    Manenkov, A A

    2011-01-01

    A role of electron paramagnetic resonance in development of quantum electronics is discussed. Basic principles and history of masers are briefly described. Spin-levels of paramagnetic ions in crystals as a very suitable object for active media of solid-state masers (called as EPR-masers) and physical processes in EPR-masers (population inversion of energy states) are analyzed. This analysis demonstrates a significant role of relaxation processes in multi-level spin-systems for efficient maser action. In this context peculiarities of spin-lattice and spin-spin cross relaxation processes in multi-level systems are analyzed. Development of EPR-masers and their application in radioastronomy and far-space communication systems are briefly described.

  11. EPR of impurity ions in disordered solids

    International Nuclear Information System (INIS)

    Kliava, J.

    1986-01-01

    The state of the art in the EPR spectroscopy of disordered solids is reviewed and theoretical aspects of the EPR shape in disordered systems are discussed. Emphasis is placed on the concept of the joint probability density of the spin Hamiltonian parameters. A survey of experimental data is provided on distributions of spin Hamiltonian parametes obtained using computer simulation techniques. A quantitative information is given on the short-range ordering in disordered materials available from EPR studies. A procedure of extracting such type of data which consists in a transformation from the distribution of the spin Hamiltonian parameters to that of atomic coordinates in the surrounding of a paramagnetic center is outlined. Numerical estimates of the degree of continuous disorder are reviewed

  12. EPR study of free radicals in bread

    Science.gov (United States)

    Yordanov, Nicola D.; Mladenova, Ralitsa

    2004-05-01

    The features of the recorded EPR spectra of paramagnetic species formed in bread and rusk are reported. The appearance of free radicals in them is only connected with their thermal treatment since the starting materials (flour and grains) exhibit very weak EPR signal. The obtained EPR spectra are complex and indicate that: (i) the relative number of paramagnetic species depends on the temperature and treating time of the raw product; (ii) the g-values are strongly temperature dependent with a tendency to coincide at t≥220 °C. Because of the relatively low (150-220 °C) temperature of thermal treatment, the studied free radicals can be assumed to appear in the course of the browning (Maillard) reaction and not to the carbonization of the material.

  13. Can EPR non-locality be geometrical?

    International Nuclear Information System (INIS)

    Ne'eman, Y.

    1995-01-01

    The presence in Quantum Mechanics of non-local correlations is one of the two fundamentally non-intuitive features of that theory. The non-local correlations themselves fall into two classes: EPR and Geometrical. The non-local characteristics of the geometrical type are well-understood and are not suspected of possibly generating acausal features, such as faster-than-light propagation of information. This has especially become true since the emergence of a geometrical treatment for the relevant gauge theories, i.e. Fiber Bundle geometry, in which the quantum non-localities are seen to correspond to pure homotopy considerations. This aspect is reviewed in section 2. Contrary-wise, from its very conception, the EPR situation was felt to be paradoxical. It has been suggested that the non-local features of EPR might also derive from geometrical considerations, like all other non-local characteristics of QM. In[7], one of the authors was able to point out several plausibility arguments for this thesis, emphasizing in particular similarities between the non-local correlations provided by any gauge field theory and those required by the preservation of the quantum numbers of the original EPR state-vector, throughout its spatially-extended mode. The derivation was, however, somewhat incomplete, especially because of the apparent difference between, on the one hand, the closed spatial loops arising in the analysis of the geometrical non-localities, from Aharonov-Bohm and Berry phases to magnetic monopoles and instantons, and on the other hand, in the EPR case, the open line drawn by the positions of the two moving decay products of the disintegrating particle. In what follows, the authors endeavor to remove this obstacle and show that as in all other QM non-localities, EPR is somehow related to closed loops, almost involving homotopy considerations. They develop this view in section 3

  14. Alanine EPR dosimetry of therapeutic irradiators

    International Nuclear Information System (INIS)

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  15. Identification of irradiated crab using EPR

    Energy Technology Data Exchange (ETDEWEB)

    Maghraby, A. [Radiation Dosimetry Department, National Institute for Standards (NIS), Ministry of Scientific Research, Haram, 12211- Giza, P.O. Box: 136 (Egypt)]. E-mail: maghrabism@yahoo.com

    2007-02-15

    EPR spectroscopy is a fast and powerful technique for the identification of irradiated food. Crab exoskeleton was divided into six parts: dactyl, cheliped, carapace, apron, swimming legs, and walking legs. Samples of the exoskeleton were prepared and irradiated to Cs-137 gamma radiation in the range (1.156-5.365 kGy). EPR spectra of unirradiated as well as irradiated samples were recorded and analyzed. Response to gamma radiation was plotted for each part of the exoskeleton, dactyl was found to be the most sensitive part, followed by the apron (38%), cheliped (37%), walking legs (30%), swimming legs (24%), and carapace (21%) relative to the dactyl response.

  16. Krótka (prehistoria argumentu EPR

    Directory of Open Access Journals (Sweden)

    Tadeusz Pabjan

    2010-12-01

    Full Text Available The 1935 thought experiment of Einstein, Podolsky and Rosen is one of the most important episodes in the history of the dispute about the correct interpretation of quantum mechanics. The present paper deals with the origin of the EPR paper and discusses some other thought experiments that preceded the formulation of the Einstein-Podolsky-Rosen argument. Special attention is paid to the evolution of a simply photon-box experiment, which was devised by Einstein in 1930 and then modified by him several times before 1935. It is argued that the scheme of the original EPR argument is in fact contained in these few seminal experiments.

  17. Biophysical EPR Studies Applied to Membrane Proteins

    Science.gov (United States)

    Sahu, Indra D; Lorigan, Gary A

    2015-01-01

    Membrane proteins are very important in controlling bioenergetics, functional activity, and initializing signal pathways in a wide variety of complicated biological systems. They also represent approximately 50% of the potential drug targets. EPR spectroscopy is a very popular and powerful biophysical tool that is used to study the structural and dynamic properties of membrane proteins. In this article, a basic overview of the most commonly used EPR techniques and examples of recent applications to answer pertinent structural and dynamic related questions on membrane protein systems will be presented. PMID:26855825

  18. Identification of irradiated crab using EPR

    International Nuclear Information System (INIS)

    Maghraby, A.

    2007-01-01

    EPR spectroscopy is a fast and powerful technique for the identification of irradiated food. Crab exoskeleton was divided into six parts: dactyl, cheliped, carapace, apron, swimming legs, and walking legs. Samples of the exoskeleton were prepared and irradiated to Cs-137 gamma radiation in the range (1.156-5.365 kGy). EPR spectra of unirradiated as well as irradiated samples were recorded and analyzed. Response to gamma radiation was plotted for each part of the exoskeleton, dactyl was found to be the most sensitive part, followed by the apron (38%), cheliped (37%), walking legs (30%), swimming legs (24%), and carapace (21%) relative to the dactyl response

  19. TL and EPR dating: some applications

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, S. [Institute of Physics, University of Sao Paulo, Sao Paulo (Brazil)

    2006-07-01

    The intensity of thermoluminescence light emitted by a crystal is a function of radiation dose. The number of defects or of radicals in a crystal or organic substances is also a function of radiation dose. Since such defects or radicals present EPR signals, the EPR intensity is also a function of radiation dose. These facts are basis for radiation dosimetry and can be applied in dating of archaeological potteries or other materials, as well as in dating geological substances such as sediments, caves speleothemes, animal teeth and bones. Recent investigation on sensitized quartz based dosimeters and dating calcite covering ancient wall painting to find early settlers in Brazil will be presented. (Author)

  20. Holographic EPR Pairs, Wormholes and Radiation

    OpenAIRE

    Chernicoff, Mariano; Güijosa, Alberto; Pedraza, Juan F.

    2013-01-01

    As evidence for the ER=EPR conjecture, it has recently been observed that the string that is holographically dual to an entangled quark-antiquark pair separating with (asymptotically) uniform acceleration has a wormhole on its worldsheet. We point out that a two-sided horizon and a wormhole actually appear for much more generic quark-antiquark trajectories, which is consistent with the fact that the members of an EPR pair need not be permanently out of causal contact. The feature that determi...

  1. Mast-sipping in EPR trademark plants

    International Nuclear Information System (INIS)

    Langenberger, Jan; Schienbein, Marcel; Geier, Roland

    2010-01-01

    For more than 20 years, AREVA applies and develops different sipping techniques to identify fuel assemblies with leaking fuel rods. For the EPR trademark reactors a Mast Sipping System with newest developments will be implemented considering radiation protection and latest standards requirements. The innovative EPR trademark Sipping System differs from previous systems in many ways. One of the main innovations is that all the necessary processes of the Sipping system have been fully digitized. Second, several ALARA design modifications have been implemented to meet the current radiation protection requirements. An additional implementable multilingual assistance program facilitates the handling of the system and helps to prevent incorrect operation. (orig.)

  2. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams

    International Nuclear Information System (INIS)

    Zeng, G G; McEwen, M R; Rogers, D W O; Klassen, N V

    2004-01-01

    The energy dependence of alanine/EPR dosimetry, in terms of absorbed dose-to-water for clinical 6, 10, 25 MV x-rays and 60 Co rays was investigated by measurements and Monte Carlo (MC) calculations. The dose rates were traceable to the NRC primary standard for absorbed dose, a sealed water calorimetry. The electron paramagnetic resonance (EPR) spectra of irradiated pellets were measured using a Bruker EMX 081 EPR spectrometer. The DOSRZnrc Monte Carlo code of the EGSnrc system was used to simulate the experimental conditions with BEAM code calculated input spectra of x-rays and γ-rays. Within the experimental uncertainty of 0.5%, the alanine EPR response to absorbed dose-to-water for x-rays was not dependent on beam quality from 6 MV to 25 MV, but on average, it was about 0.6% lower than its response to 60 Co gamma rays. Combining experimental data with Monte Carlo calculations, it is found that the alanine/EPR response per unit absorbed dose-to-alanine is the same for clinical x-rays and 60 Co gamma rays within the uncertainty of 0.6%. Monte Carlo simulations showed that neither the presence of PMMA holder nor varying the dosimeter thickness between 1 mm and 5 mm has significant effect on the energy dependence of alanine/EPR dosimetry within the calculation uncertainty of 0.3%

  3. Design of the EPR containment

    International Nuclear Information System (INIS)

    Appell, B.; Zaiss, W.

    1996-01-01

    In order to respect the safety objectives set for the EPR (European Pressurized water Reactor), the confinement function must be designed to guard against in the design uncontrolled releases in the environment in all conditions taken into account and to preserve its structural integrity. The concept chosen is a double-wall confinement with technology identical derived from the current French N4 containments and the associated systems ensuring the isolation and the control of leaks. The basic principles aiming to minimize leaks are as follows: no direct leak; state-of-the-art leak tight design of the systems and components passing through the containment building; recovery of potential leaks through the inner wall and the penetration sleeves in the inter-wall space; recovery in the peripheral buildings; and specific measures if necessary. The inner wall is a prestressed concrete shell (55 tendons cables arranged in two horizontal layers and a vertical layer for the barrel) without liner, of free volume 90000 m 3 , an internal diameter of 48 m and 1.3 m thickness. The free volume is chosen so as to rule out the risk of global detonation and the use of catalytic recombiners limits the risk of hydrogen explosion. The design pressure (6.5 bar abs) and temperature of the inner wall are defined for a given volume by the set of three conditions: Pee-4 conditions such as LOCA or SLB, global deflagration of hydrogen and core melt scenario. The rate of leakage in accident conditions from the inner wall must not be higher than 1% per day. The chosen concept must enable satisfactory leak tightness to be preserved for beyond design conditions in order to have margins and to guard against phenomenological uncertainties. The possibility of adding an internal composite liner is being studied. A large scale mockup is being built to validate the hypothesis and methods of leak rates of the inner wall and for the performance testing of the composite liner. The outer wall, made of

  4. Versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Adduci, D.J.

    1979-05-01

    A description of the sequence of events and the decisions leading to the design of a versatile pulse programmer for pulsed NMR are presented. Background and application information is discussed in order that the reader might better understand the role of the pulse programmer in a NMR spectrometer. Various other design approaches are presented as a basis for comparison. Specifications for this design are proposed, the hardware implementation of the specifications is discussed, and the software operating system is presented

  5. Versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Adduci, D.J.

    1979-05-01

    A description of the sequence of events and the decisions leading to the design of a versatile pulse programmer for pulsed NMR are presented. Background and application information is discussed in order that the reader might better understand the role of the pulse programmer in a NMR spectrometer. Various other design approaches are presented as a basis for comparison. Specifications for this design are proposed, the hardware implementation of the specifications is discussed, and the software operating system is presented.

  6. Preliminary study on electron paramagnetic resonance (EPR) signal properties of mobile phone components for dose estimation in radiation accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byeong Ryong; Ha, Wi Ho; Park, Sun Hoo; Lee, Jin Kyeong; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2015-12-15

    We have investigated the EPR signal properties in 12 components of two mobile phones (LCD, OLED) using electron paramagnetic resonance (EPR) spectrometer in this study.EPR measurements were performed at normal atmospheric conditions using Bruker EXEXSYS-II E500 spectrometer with X-band bridge, and samples were irradiated by {sup 137}C{sub s} gamma-ray source. To identify the presence of radiation-induced signal (RIS), the EPR spectra of each sample were measured unirradiated and irradiated at 50 Gy. Then, dose-response curve and signal intensity variating by time after irradiation were measured. As a result, the signal intensity increased after irradiation in all samples except the USIM plastic and IC chip. Among the samples, cover glass(CG), lens, light guide plate(LGP) and diffusion sheet have shown fine linearity (R{sup 2} > 0.99). Especially, the LGP had ideal characteristics for dosimetry because there were no signal in 0 Gy and high rate of increase in RIS. However, this sample showed weakness in fading. Signal intensity of LGP and Diffusion Sheet decreased by 50% within 72 hours after irradiation, while signals of Cover Glass and Lens were stably preserved during the short period of time. In order to apply rapidly EPR dosimetry using mobile phone components in large-scale radiation accidents, further studies on signal differences for same components of the different mobile phone, fading, pretreatment of samples and processing of background signal are needed. However, it will be possible to do dosimetry by dose-additive method or comparative method using unirradiated same product in small-scale accident.

  7. Application of modular neutron spectrometer to measure neutron spectra from fission of 252Cf

    International Nuclear Information System (INIS)

    Szeflinski, Z.; Osuch, S.; Popkiewicz, M.; Wilhelmi, Z.; Zelazny, Z.

    1996-01-01

    The neutron spectrometer MONA (Modular Neutron Array) and its test has been described. The spectrometers consist of eight BC-501A liquid scintillator detectors of BICRON which allow one to distinguish between the pulses from gamma quanta and neutrons using pulse shape discrimination (PSD) method. The electronic equipment for the PSD and the test result using the 252 Cf radioactive source are presented

  8. Spherical grating spectrometers

    Science.gov (United States)

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  9. Moving Difference (MDIFF) Non-adiabatic rapid sweep (NARS) EPR of copper(II)

    Science.gov (United States)

    Hyde, James S.; Bennett, Brian; Kittell, Aaron W.; Kowalski, Jason M.; Sidabras, Jason W.

    2014-01-01

    Non Adiabatic Rapid Sweep (NARS) EPR spectroscopy has been introduced for application to nitroxide-labeled biological samples (AW Kittell et al, (2011)). Displays are pure absorption, and are built up by acquiring data in spectral segments that are concatenated. In this paper we extend the method to frozen solutions of copper-imidazole, a square planar copper complex with four in-plane nitrogen ligands. Pure absorption spectra are created from concatenation of 170 5-gauss segments spanning 850 G at 1.9 GHz. These spectra, however, are not directly useful since nitrogen superhyperfine couplings are barely visible. Application of the moving difference (MDIFF) algorithm to the digitized NARS pure absorption spectrum is used to produce spectra that are analogous to the first harmonic EPR. The signal intensity is about 4 times higher than when using conventional 100 kHz field modulation, depending on line shape. MDIFF not only filters the spectrum, but also the noise, resulting in further improvement of the SNR for the same signal acquisition time. The MDIFF amplitude can be optimized retrospectively, different spectral regions can be examined at different amplitudes, and an amplitude can be used that is substantially greater than the upper limit of the field modulation amplitude of a conventional EPR spectrometer, which improves the signal-to-noise ratio of broad lines. PMID:24036469

  10. Flexible, wireless, inductively coupled surface coil resonator for EPR tooth dosimetry

    International Nuclear Information System (INIS)

    Schreiber, Wilson; Petryakov, Sergey V.; Kmiec, Maciej M.; Feldman, Matthew A.; Wood, Victoria A.; Boyle, Holly K.; Flood, Ann Barry; Williams, Benjamin B.; Swartz, Harold M.; Meaney, Paul M.

    2016-01-01

    Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario. (authors)

  11. MDEP Common Position No EPR-01 - Common positions on the EPR instrumentation and controls design

    International Nuclear Information System (INIS)

    2010-01-01

    The purpose of the EPR Working Group (EPRWG) of the Multinational Design Evaluation Program (MDEP) is to identify common positions among the regulators reviewing the EPR Instrumentation and Controls (I and C) Systems in order to: 1. Promote understanding of each country 's regulatory decisions and basis for the decisions, 2. Enhance communication among the members and with external stakeholders, 3. Identify areas where harmonization and convergence of regulations, standards, and guidance can be achieved or improved, and 4. Supports standardization of new reactor designs. Since January 2008, the EPR I and C Technical Expert Subgroup (TESG) members met five times to exchange information regarding their country 's review of the EPR I and C design. The EPR I and C TESG consists of regulators from China, Canada, Finland, France, the United Kingdom, and the United States. The information exchange includes presentation of each country 's review status and technical issues, sharing of guidance documents, and sharing of regulatory decision documents. The TESG focused on the following four core areas of the EPR I and C design: 1. I and C System Independence (particularly for data communications), 2. Level of Defense and Diversity (back-up systems), 3. Qualification/quality of digital platforms, 4. Categorization/classification of systems and functions. As meetings were conducted, some areas were emphasized more depending on the significance of the issues for each country. During the TESG interactions, it became apparent that there were aspects of the EPR design where the countries had common agreement. On November 2, 2009, three of the subgroup countries, France, Finland and the United Kingdom, issued a joint regulatory position on the EPR I and C design as result of the 'Groupe Permanent' meeting in France. This statement of common positions expands upon that joint regulatory position

  12. EPR Study of Free Radicals in Cotton Fiber for Its Potential Use as a Fortuitous Dosimeter in Radiological Accidents

    International Nuclear Information System (INIS)

    Sudprasert, W.; Insuan, P.; Khamkhrongmee, S.

    2014-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was applied to characterize radiation- induced free radicals in cotton fiber in order to determine the possibility for using cotton as a fortuitous dosimeter in accidental exposures to radiation. Cotton fabrics were irradiated at 0.1, 0.5, 1, 2, 10, 50 and 500 Gy using a 60Co gamma source. The irradiated samples were then stored in the dark under controlled environmental conditions for 1, 15, 35 and 60 days. The EPR spectra were observed in samples using a Bruker EMX X-band spectrometer equipped with a TE102 rectangular cavity. The EPR signal intensities of irradiated samples were determined from peak-to-peak amplitudes of EPR spectra and compared to unirradiated samples. The following optimum parameters were used: modulation frequency,100 kHz; microwave frequency, 9.84 GHz; modulation amplitude, 1.8 mT; microwave power,1.0 mW; time constant, 665 ms; conversion time, 41 ms; and sweep time, 41.98 s. The EPR spectra of unirradiated samples show a singlet line with g = 2.006 due to stable organic radicals pre-existing in the cotton fibers, whereas those of irradiated samples show the same pattern with different signal intensities according to the doses. Irradiation increased the signal intensity in a dose dependent manner. The signal intensity exhibited an exponential decay with storage time from 1 to 60 days. Obviously, the degree of fading of EPR intensity did not depend on the absorbed dose from 0.1-50 Gy. The maximum fading was about 60% at 60 days storage of irradiated samples at all doses. However the post-irradiation signal appeared to be detectable up to 60 days after irradiation. The results indicate the potential of using cotton as a fortuitous dosimeter in radiological accidents.

  13. Polymer therapeutics and the EPR effect.

    Science.gov (United States)

    Maeda, Hiroshi

    History of the EPR (enhanced permeability and retention) effect is discussed, which goes back to the analyses of molecular pathology in bacterial infection and edema (extravasation) formation. The first mediator we found for extravasation was bradykinin. Later on, were found nitric oxide and superoxide, then formation of peroxynitrite, that activates procollagenase. In this inflammatory setting many other vascular mediators are involved that are also common to cancer vasculature. Obviously cancer vasculature is defective architechtally, and this makes macromolecular drugs more permeable through the vascular wall. The importance of this pathophysiological event of EPR effect can be applied to macromolecular drug-delivery, or tumor selective delivery, which takes hours to achieve in the primary as well as metastatic tumors, not to mention of the inflamed tissues. The retention of the EPR means that such drugs will be retained in tumor tissues more than days to weeks. This was demonstrated initially, and most dramatically, using SMANCS, a protein-polymer conjugated-drug dissolved in lipid contrast medium (Lipiodol) by administering intraarterially. For disseminating the EPR concept globally, or in the scientific community, Professor Ruth Duncan played a key role at the early stage, as she worked extensively on polymer- therapeutics, and knew its importance.

  14. Teaching the EPR Paradox at High School?

    Science.gov (United States)

    Pospiech, Gesche

    1999-01-01

    Argues the importance of students at university and in the final years of high school gaining an appreciation of the principles of quantum mechanics. Presents the EPR gedanken experiment (thought experiment) as a method of teaching the principles of quantum mechanics. (Author/CCM)

  15. EPR: outlines of research and development

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The articles give an overview of the research and development presently under way for the future pressurized water reactors to be constructed in Europe, and particularly the French and German EPR (European Pressurized Reactor). Such an analysis deals essentially with respect to the pressurized water reactors now in operation. (author)

  16. Investigation of EPR signals on tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Pavlenko, A; Mironova-Ulmane, N; Polakov, M; Riekstina, D [Institute of Solid State Physics, University of Latvia, Riga (Latvia)

    2007-12-15

    Calcified tissues are involved in continues metabolic process in human organism exchanging a number of chemical elements with environment. The rate of biochemical reactions is tissue dependent and the slowest one at the tooth enamel, the most mineralized tissue of human organism. The long time stability and unique chemical composition make tooth enamel suitable for number of application. The assessment of individual radiation dose by Electron Paramagnetic Resonance (EPR) and evaluations of elemental composition by Instrumentation Neutron Activation Analysis (INAA) are the well known procedures where properties of tooth enamel intensively used. The current work is focused on investigation of EPR signals and determination of chemical composition on several teeth samples having different origin. The EPR spectra and INAA element content of milk tooth, caries tooth, and paradantose tooth have been compared to each other. The results showed that the intensity of EPR signal is much higher for the caries tooth than the for paradantose tooth that is in agreement with depleted Ca content.

  17. EPR application in medicine and biology

    Czech Academy of Sciences Publication Activity Database

    Stopka, Pavel; Křížová, Jana; Káfuňková, Eva

    2005-01-01

    Roč. 99, č. 14 (2005), s. 190-192 ISSN 0009-2770 R&D Projects: GA MZd(CZ) NB7377; GA MZd(CZ) NL7567 Institutional research plan: CEZ:AV0Z40320502 Keywords : EPR application Subject RIV: CA - Inorganic Chemistry Impact factor: 0.445, year: 2005

  18. Zavoisky and the Discovery of EPR

    Indian Academy of Sciences (India)

    IAS Admin

    moved to Kazan. In 1926, after finishing the nine-year secondary ... year student, he got a patent for an invention. Zavoisky was ... Early Attempts at NMR and Interruption by World War II ... band modulation) and, in some cases, he did not even apply the constant ... was awarded the Lenin Prize for the discovery of EPR. In the.

  19. The EPR detection of radiation treated foodstuffs

    International Nuclear Information System (INIS)

    Stachowicz, W.; Burlinska, G.; Michalik, J.; Ostrowski, K.; Dziedzic-Goclawska, A.

    1993-01-01

    The short paper by a Polish study group describes the results of the use of Electron Paramagnetic Resonance (EPR) Spectroscopy in the detection of irradiation to food. Pultry, fresh-water fish and sea fish as well as various fruits and yellow boletus are dealt with in some detail. (VHE) [de

  20. Improved sensitivity for W-band Gd(III)-Gd(III) and nitroxide-nitroxide DEER measurements with shaped pulses

    Science.gov (United States)

    Bahrenberg, Thorsten; Rosenski, Yael; Carmieli, Raanan; Zibzener, Koby; Qi, Mian; Frydman, Veronica; Godt, Adelheid; Goldfarb, Daniella; Feintuch, Akiva

    2017-10-01

    Chirp and shaped pulses have been recently shown to be highly advantageous for improving sensitivity in DEER (double electron-electron resonance, also called PELDOR) measurements due to their large excitation bandwidth. The implementation of such pulses for pulse EPR has become feasible due to the availability of arbitrary waveform generators (AWG) with high sampling rates to support pulse shaping for pulses with tens of nanoseconds duration. Here we present a setup for obtaining chirp pulses on our home-built W-band (95 GHz) spectrometer and demonstrate its performance on Gd(III)-Gd(III) and nitroxide-nitroxide DEER measurements. We carried out an extensive optimization procedure on two model systems, Gd(III)-PyMTA-spacer-Gd(III)-PyMTA (Gd-PyMTA ruler; zero-field splitting parameter (ZFS) D ∼ 1150 MHz) as well as nitroxide-spacer-nitroxide (nitroxide ruler) to evaluate the applicability of shaped pulses to Gd(III) complexes and nitroxides, which are two important classes of spin labels used in modern DEER/EPR experiments. We applied our findings to ubiquitin, doubly labeled with Gd-DOTA-monoamide (D ∼ 550 MHz) as a model for a system with a small ZFS. Our experiments were focused on the questions (i) what are the best conditions for positioning of the detection frequency, (ii) which pump pulse parameters (bandwidth, positioning in the spectrum, length) yield the best signal-to-noise ratio (SNR) improvements when compared to classical DEER, and (iii) how do the sample's spectral parameters influence the experiment. For the nitroxide ruler, we report an improvement of up to 1.9 in total SNR, while for the Gd-PyMTA ruler the improvement was 3.1-3.4 and for Gd-DOTA-monoamide labeled ubiquitin it was a factor of 1.8. Whereas for the Gd-PyMTA ruler the two setups pump on maximum and observe on maximum gave about the same improvement, for Gd-DOTA-monoamide a significant difference was found. In general the choice of the best set of parameters depends on the D

  1. New Generation of self-calibrated SS/EPR dosimeters: Alanine/EPR dosimeters

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Gancheva, V.

    1999-01-01

    A new type of solid state/EPR dosimeters is described. Principally, it contains radiation sensitive diamagnetic material, some quantity of EPR active, but radiation insensitive, substance (for example Mn 2+ /MgO) and a binding material. In the present case alanine is used as a radiation sensitive substance. With this dosimeter, the EPR spectra of alanine and Mn 2+ are simultaneously recorded and the calibration graph represents the ratio of alanine versus Mn 2+ EPR signal intensity as a function of absorbed dose. In this way the reproducibility of the results is expected to be improved significantly including their intercomparison among different laboratories. Homogeneity of the prepared dosimeters and their behaviour (fading of EPR signals with time, influence of different meteorological conditions) show satisfactory reproducibility and stability with time. Because two different EPR active samples are recorded simultaneously, the influence of some instrument setting parameters (microwave power, modulation amplitude and modulation frequency) on the ratio I alanine /I Mn is also investigated. (author)

  2. Assessment of performance parameters for EPR dosimetry with tooth enamel

    International Nuclear Information System (INIS)

    Wieser, A.; Fattibene, P.; Shishkina, E.A.; Ivanov, D.V.; De Coste, V.; Guettler, A.; Onori, S.

    2008-01-01

    In the framework of a comparison between three laboratories, electron paramagnetic resonance (EPR) signal-to-dose response curves were measured for sets of 30 tooth enamel samples and the variance of EPR measurements in dependence on absorbed dose was evaluated, in nine combinations of laboratory of sample preparation and EPR evaluation, respectively. As a test for benchmarking of EPR evaluation, the parameters 'critical dose' and 'limit of detection' were proposed as performance parameters following definitions from chemical-metrology, and a model function was suggested for analytical formulation of the dependence of the variance of EPR measurement on absorbed dose. First estimates of limits of detection by weighted and unweighted fitting resulted in the range 101-552 and 67-561 mGy, respectively, and were generally larger with weighted than with unweighted fitting. Indication was found for the influence of methodology of sample preparation and applied EPR measurement parameters on performance of EPR dosimetry with tooth enamel

  3. The SPEDE spectrometer

    Science.gov (United States)

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  4. The photon energy dependence of the alanine/EPR dosimetry system, an experimental investigation

    International Nuclear Information System (INIS)

    Bergstrand, E.S.; Hole, E.O.; Shortt, K.R.; Ross, C.K.

    2002-01-01

    The energy dependence of a dosimetry system based on electron paramagnetic resonance (EPR) spectroscopy of alanine has been studied to determine its suitability for use in dose verification for radiotherapy. A few experiments with high-energy photon irradiation of alanine have been reported in the literature. However, the reported results disagree whether the ratio of dose in alanine to dose in water is independent of the radiation energy or whether there is a small dependence for photon energies of relevance to radiotherapy. The concentration of free radicals in alanine is proportional to the absorbed dose in alanine over a wide dose range covering three decades. The relative number of radicals may be determined by examining the EPR spectrum, and hence it is possible to determine the dose with a system that has been calibrated using a known dose of 60 Co radiation. In the present work, irradiations of alanine dosimeters were performed at the National Research Council (NRC), in Ottawa, Canada. The radiation qualities investigated were 10, 20 and 30 MV x-rays using the NRC linac. For each radiation quality, 30 dosimeters were irradiated in a water phantom with a level of absorbed dose to water ranging from 10 to 50 Gy. For reference purposes, irradiations using the NRC 60 Co source were performed on more or less the same day as the irradiations at each specific linac quality. In all beams, the dose to water was measured using a graphite-walled NE2571 ionisation chamber that was originally calibrated by comparison with a sealed-water calorimeter. The alanine dosimeters were evaluated at the EPR laboratory at the University of Oslo, Norway, using an X-band Bruker ESP300E spectrometer with a rectangular double resonator. One of the resonators contained a Mn 2+ /MgO sample that was read after each dosimeter reading, in order to provide independence from short-term sensitivity fluctuations in the spectrometer. All dosimeters irradiated at one specific linac quality were

  5. A dozen useful tips on how to minimise the influence of sources of error in quantitative electron paramagnetic resonance (EPR) spectroscopy-A review

    International Nuclear Information System (INIS)

    Mazur, Milan

    2006-01-01

    in our quantitative EPR experiments (with a Bruker ER 200 D-SRC EPR spectrometer with a Bruker double TE 104 rectangular cavity and air conditioning) the EPR signal intensity of a wide range of samples could be obtained with the experimental errors between 3 and 5%. However, if these special precautions were not employed the errors could be in excess of 20% or more. We believe that these tips are helpful in quantitative EPR practice

  6. Mixed clusters from the coexpansion of C2F6 and n2 in a pulsed, supersonic expansion cluster ion source and beam deflection time-of-flight mass spectrometer: A first application

    Science.gov (United States)

    Thompson, Steven D.

    The following topics are discussed: (1) cluster ion genesis; (2) cluster ion detection; (3) Ion source; (4) pulse valve; (5) e-gun; (6) Ion optics; (7) a first order model; and (8) a modified Bakker's model.

  7. Mass spectrometers in medicine

    International Nuclear Information System (INIS)

    Bushman, J.A.

    1975-01-01

    This paper describes how the mass spectrometer enables true lung function, namely the exchange of gases between the environment and the organism, to be measured. This has greatly improved the understanding of respiratory disease and the latest generation of respiratory mass spectrometers will do much to increase the application of the technique. (author)

  8. The Omicron Spectrometer

    CERN Document Server

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  9. Computerized mass spectrometer data system at LLL

    International Nuclear Information System (INIS)

    Friesen, R.D.; Dupzyk, R.J.

    1976-01-01

    The data systems on the three mass spectrometers at LLL are computer-controlled, pulse-counting systems synchronized to a repeatedly swept magnetic field. The data are accumulated in the memory of the computer or in a Nuclear Data ND 180 in a multi-scaler mode of operation. This mode of data acquisition allows a continuous check of the background stability and makes tune-up easier. But the main benefit is a reduction in the required ion emission rate stability. By the use of standards to set the system dead time, we have been able to utilize the sensitivity of a pulse counting system without the expense of exotic equipment

  10. Mass spectrometer data system at LLL

    International Nuclear Information System (INIS)

    Friesen, R.D.

    1975-01-01

    The data systems on the three mass spectrometers at LLL are computer-controlled, pulse-counting systems synchronized to a repeatedly-swept magnetic field. The data are accumulated in the memory of the computer or in a Nuclear Data ND 180 in a multi-scaler mode of operation. This mode of sweeping allows a continuous check of the background stability and makes tune-up easier. But the main benefit is a reduction in the required ion emission rate stability. By the use of standards to set the system dead time, we have been able to utilize the sensitivity of a pulse counting system without the expense of exotic equipment

  11. An intense transmission spectrometer for ISIS

    International Nuclear Information System (INIS)

    Newport, R.J.; Howells, W.S.

    1986-07-01

    The report seeks to outline a design for an intense transmission spectrometer (ITS) suitable for installation on the pulsed neutron source ISIS. The performance of the instrument is evaluated and several examples of the areas of science made accessible are discussed. It is shown that the proposed design will represent a scientifically valuable and cost-effective addition to the present suite of ISIS instruments. (author)

  12. Steering, Entanglement, Nonlocality, and the EPR Paradox

    Science.gov (United States)

    Wiseman, Howard; Jones, Steve; Andrew, Doherty

    2007-06-01

    The concept of steering was introduced by Schroedinger in 1935 as a generalization of the EPR paradox for arbitrary pure bipartite entangled states and arbitrary measurements by one party. Until now, it has never been rigorously defined, so it has not been known (for example) what mixed states are steerable (that is, can be used to exhibit steering). We provide an operational definition, from which we prove (by considering Werner states and Isotropic states) that steerable states are a strict subset of the entangled states, and a strict superset of the states that can exhibit Bell-nonlocality. For arbitrary bipartite Gaussian states we derive a linear matrix inequality that decides the question of steerability via Gaussian measurements, and we relate this to the original EPR paradox.

  13. The long way to the EPR

    International Nuclear Information System (INIS)

    Berke, C.

    1997-01-01

    At the joint conference organized by the German Kerntechnische Gesellschaft (KTG) e.V. and the French Societe Francaise d'Energie Nucleaire (SFEN) in Cologne, the announcement was made on October 20, 1997 that Jean Claude Leny will be appointed Honorary Member of KTG. For reasons of ill health the new honorary member was prevented from attending the conference. In his place, Claus Berke sketched the history of the European Pressurized Water Reactor (EPR) and presented an overview of nuclear development in France and in Germany. Developing one standard reactor model in the primary objective of German-French cooperation in reactor development. The EPR is to replace the present nuclear generating units in France and Germany after the end of their planned service life, and is to be marketed as a standard export line. (orig.) [de

  14. EPR becomes reality at Finland's Olkiluoto 3

    International Nuclear Information System (INIS)

    Gueldner, R.; Giese, U.

    2005-01-01

    The EPR is a third-generation pressurized water reactor (PWR). Its development was started in 1992 by Framatome and Siemens within a Franco-German partnership. Since 2001 this work has been continued by Framatome ANP, which was formed when the two companies merged their nuclear businesses. The French company AREVA, world market leader in nuclear technology, holds a 66% share in Framatome ANP, with Siemens owning 34%. From the very start, development of the EPR was focused on improving plant safety and economics even further. The new reactor development was jointly financed together with the leading power utilities of both countries. The first steps towards realization of an EPR nuclear power plant were taken at Olkiluoto, Finland in 2004, consisting of initial preparation of the construction site. By mid-February 2005 the local municipality - Eurajoki - had issued a construction permit, and the Finnish Government a construction license pursuant to the Finnish Nuclear Energy Act. This had been preceded by a preliminary safety assessment prepared by the Finnish Radiation and Nuclear Safety Authority (STUK) for the Finnish Ministry of Trade and Industry in which STUK verified that it did not see any safety-related issues opposing issuance of the nuclear construction license. STUK emphasized that the evolutionary design of the EPR had been further improved by AREVA compared to the previous product lines. Concreting work began this spring and the unit will start commercial operation in 2009. Construction of an EPR has also been given the political go-ahead in France. According to the utility Electricite de France (EDF) the new reactor will be built as a forerunner of a later series at the site of Flamanville in Normandy. Construction is scheduled to begin in 2007. An EPR nuclear power plant has a rated electric capacity of around 1600 MW, depending on specific site conditions. Being the product of intense bilateral cooperation the EPR combines the technological

  15. A theoretical interpretation of EPR and ENDOR

    International Nuclear Information System (INIS)

    Matos, M.O.M. de.

    1975-08-01

    To interpret the EPR and ENDOR results of the U 2 center in SrF 2 , two wavefunctions are proposed to describe the unpaired electron of the defect. Use is made of two different models in order to obtain the wavefunctions: the Heitler-London and that of molecular orbitals models. The Pauli repulsion (overlap of wavefunctions) is discussed as well as covalency mechanisms and their influence in the calculation of the hyperfine constants due to magnetic interaction of the unpaired electron and the magnetic nucleus of the cristal. A small amount of covalency between the ground state of the interstitial Hydrogen atom and the 2p shell of the F - ions of the first cristaline shell is introduced fenomenologically in the molecular orbitals model. Both methods are discussed by comparing the theoretical calculations of the hyperfine constants with the measured experimental values obtained with the EPR and ENDOR techniques. (Author) [pt

  16. Holographic EPR pairs, wormholes and radiation

    Science.gov (United States)

    Chernicoff, Mariano; Güijosa, Alberto; Pedraza, Juan F.

    2013-10-01

    As evidence for the ER = EPR conjecture, it has recently been observed that the string that is holographically dual to an entangled quark-antiquark pair separating with (asymptotically) uniform acceleration has a wormhole on its worldsheet. We point out that a two-sided horizon and a wormhole actually appear for much more generic quark-antiquark trajectories, which is consistent with the fact that the members of an EPR pair need not be permanently out of causal contact. The feature that determines whether the causal structure of the string worldsheet is trivial or not turns out to be the emission of gluonic radiation by the dual quark and antiquark. In the strongly-coupled gauge theory, it is only when radiation is emitted that one obtains an unambiguous separation of the pair into entangled subsystems, and this is what is reflected on the gravity side by the existence of the worldsheet horizon.

  17. Multisite EPR oximetry from multiple quadrature harmonics.

    Science.gov (United States)

    Ahmad, R; Som, S; Johnson, D H; Zweier, J L; Kuppusamy, P; Potter, L C

    2012-01-01

    Multisite continuous wave (CW) electron paramagnetic resonance (EPR) oximetry using multiple quadrature field modulation harmonics is presented. First, a recently developed digital receiver is used to extract multiple harmonics of field modulated projection data. Second, a forward model is presented that relates the projection data to unknown parameters, including linewidth at each site. Third, a maximum likelihood estimator of unknown parameters is reported using an iterative algorithm capable of jointly processing multiple quadrature harmonics. The data modeling and processing are applicable for parametric lineshapes under nonsaturating conditions. Joint processing of multiple harmonics leads to 2-3-fold acceleration of EPR data acquisition. For demonstration in two spatial dimensions, both simulations and phantom studies on an L-band system are reported. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Teichmuller Space Resolution of the EPR Paradox

    Science.gov (United States)

    Winterberg, Friedwardt

    2013-04-01

    The mystery of Newton's action-at-a-distance law of gravity was resolved by Einstein with Riemann's non-Euclidean geometry, which permitted the explanation of the departure from Newton's law for the motion of Mercury. It is here proposed that the similarly mysterious non-local EPR-type quantum correlations may be explained by a Teichmuller space geometry below the Planck length, for which an experiment for its verification is proposed.

  19. Steering, Entanglement, Nonlocality, and the EPR Paradox

    OpenAIRE

    Wiseman, H. M.; Jones, S. J.; Doherty, A. C.

    2006-01-01

    The concept of steering was introduced by Schrodinger in 1935 as a generalization of the EPR paradox for arbitrary pure bipartite entangled states and arbitrary measurements by one party. Until now, it has never been rigorously defined, so it has not been known (for example) what mixed states are steerable (that is, can be used to exhibit steering). We provide an operational definition, from which we prove (by considering Werner states and Isotropic states) that steerable states are a strict ...

  20. Seventy Years of the EPR Paradox

    Science.gov (United States)

    Kupczynski, Marian

    2006-11-01

    In spite of the fact that statistical predictions of quantum theory (QT) can only be tested if large amount of data is available a claim has been made that QT provides the most complete description of an individual physical system. Einstein's opposition to this claim and the paradox he presented in the article written together with Podolsky and Rosen in 1935 inspired generations of physicists in their quest for better understanding of QT. Seventy years after EPR article it is clear that without deep understanding of the character and limitations of QT one may not hope to find a meaningful unified theory of all physical interactions, manipulate qubits or construct a quantum computer.. In this paper we present shortly the EPR paper, the discussion, which followed it and Bell inequalities (BI). To avoid various paradoxes we advocate purely statistical contextual interpretation (PSC) of QT. According to PSC a state vector is not an attribute of a single electron, photon, trapped ion or quantum dot. A value of an observable assigned to a physical system has only a meaning in a context of a particular physical experiment PSC does not provide any mental space-time picture of sub phenomena. The EPR paradox is avoided because the reduction of the state vector in the measurement process is a passage from a description of the whole ensemble of the experimental results to a particular sub-ensemble of these results. We show that the violation of BI is neither a proof of the completeness of QT nor of its non-locality. Therefore we rephrase the EPR question and ask whether QT is "predictably "complete or in other words does it provide the complete description of experimental data. To test the "predictable completeness" it is not necessary to perform additional experiments it is sufficient to analyze more in detail the existing experimental data by using various non-parametric purity tests and other specific statistical tools invented to study the fine structure the time-series.

  1. Seventy Years of the EPR Paradox

    OpenAIRE

    Kupczynski, Marian

    2007-01-01

    In spite of the fact that statistical predictions of quantum theory (QT) can only be tested if large amount of data is available a claim has been made that QT provides the most complete description of an individual physical system. Einstein's opposition to this claim and the paradox he presented in the article written together with Podolsky and Rosen in 1935 inspired generations of physicists in their quest for better understanding of QT. Seventy years after EPR article it is clear that witho...

  2. Is the EPR paradox really a paradox?

    OpenAIRE

    Tartaglia, A.

    1998-01-01

    The EPR paradox and the meaning of the Bell inequality are discussed. It is shown that considering the quantum objects as carrying with them ''instruction kits'' telling them what to do when meeting a measurement apparatus any paradox disappears. In this view the quantum state is characterized by the prescribed behaviour rather than by the specific value a parameter assumes as a result of an interaction.

  3. Should the EPR be financed by industrialists?

    International Nuclear Information System (INIS)

    Jemain, A.

    2005-01-01

    As a reciprocal arrangement, the industrialists should be invited to contribute to the financing of the new generation reactor EPR (European pressurized reactor) which will be built in Flamanville (Manche, France). In exchange to their financial participation, the industrialists will receive the contractual warranty of stable electricity prices during 10 to 15 years periods. This short paper presents the opposite opinion of two representative of French industries concerning this proposal. Short paper. (J.S.)

  4. EPR Test with Photons and Kaons Analogies

    CERN Document Server

    Gisin, Nicolas

    2001-01-01

    We present a unified formalism describing EPR test using spin 1/2 particles, photons and kaons. This facilitates the comparison between existing experiments using photons and kaons. It underlines the similarities between birefringence and polarization dependent losses that affects experiments using optical fibers and mixing and decay that are intrinsic to the kaons. We also discuss the limitation these two characteristics impose on the testing of Bell's inequality.

  5. On Popper's new EPR-Experiment

    International Nuclear Information System (INIS)

    Bedford, D.; Selleri, F.

    1985-01-01

    It is scientifically reasonable to search for particular statistical ensembles to which the standard quantum rules (like Heisenberg relations) do not apply: these rules would instead be applicable to more general statistical ensembles (which might be called ''standard quantum ensembles''). Along these lines, Popper has recently proposed what he calls ''a new version of the EPR experiment'' in which the Copenhagen and statistical interpretations of quantum mechanics apparently lead to distinguishably different predictions

  6. Self-testing through EPR-steering

    International Nuclear Information System (INIS)

    Šupić, Ivan; Hoban, Matty J

    2016-01-01

    The verification of quantum devices is an important aspect of quantum information, especially with the emergence of more advanced experimental implementations of quantum computation and secure communication. Within this, the theory of device-independent robust self-testing via Bell tests has reached a level of maturity now that many quantum states and measurements can be verified without direct access to the quantum systems: interaction with the devices is solely classical. However, the requirements for this robust level of verification are daunting and require high levels of experimental accuracy. In this paper we discuss the possibility of self-testing where we only have direct access to one part of the quantum device. This motivates the study of self-testing via EPR-steering, an intermediate form of entanglement verification between full state tomography and Bell tests. Quantum non-locality implies EPR-steering so results in the former can apply in the latter, but we ask what advantages may be gleaned from the latter over the former given that one can do partial state tomography? We show that in the case of self-testing a maximally entangled two-qubit state, or ebit, EPR-steering allows for simpler analysis and better error tolerance than in the case of full device-independence. On the other hand, this improvement is only a constant improvement and (up to constants) is the best one can hope for. Finally, we indicate that the main advantage in self-testing based on EPR-steering could be in the case of self-testing multi-partite quantum states and measurements. For example, it may be easier to establish a tensor product structure for a particular party’s Hilbert space even if we do not have access to their part of the global quantum system. (paper)

  7. The Finnish EPR dependent on a bridge

    International Nuclear Information System (INIS)

    Dupin, L.

    2010-01-01

    A new conflict has emerged between the main contractor Areva and its client TVO, the Finnish energy group. The qualification of a handling bridge has delayed the OL3 project of third EPR reactor at Olkiluoto, Finland. The disagreement concerns the testing procedure and may induce a two year delay in the completion of the project which is now planned for 2012 instead of 2010 initially. (J.S.)

  8. The EPR operators are trained on simulator

    International Nuclear Information System (INIS)

    Maincent, G.

    2009-01-01

    Three years before the EPR reactor of Flamanville (Normandie, France) is generating its very first kilowatt hours, Electricite de France has started to train its teams on a simulator which reproduces the man-machine interface of the future nuclear power plant. The simulator used is an evolutive tool specific to the Flamanville reactor and capable to test about 20 different accidental situations. (J.S.)

  9. EPR in non-doped irradiated polyacetylene

    International Nuclear Information System (INIS)

    Hola, O.; Stasko, A.; Foeldesova, M.

    1993-01-01

    The influence of γ-irradiation on the paramagnetic properties of non-doped polyacetylene at low and high radiation doses has been studied and summarized. The dependence of the EPR spectra on the radiation dose in irradiated polyacetylene has been measured. No essential changes of the spin mobility as a consequence of irradiation were observed. The measurements of spin concentration confirm the high resistivity of non-doped polyacetylene to radiation. (author) 9 refs

  10. ISS protocol for EPR tooth dosimetry

    International Nuclear Information System (INIS)

    Onori, S.; Aragno, D.; Fattibene, P.; Petetti, E.; Pressello, M.C.

    2000-01-01

    The accuracy in Electron Paramagnetic Resonance (EPR) dose reconstruction with tooth enamel is affected by sample preparation, dosimetric signal amplitude evaluation and unknown dose estimate. Worldwide efforts in the field of EPR dose reconstruction with tooth enamel are focused on the optimization of the three mentioned steps in dose assessment. In the present work, the protocol implemented at ISS in the framework of the European Community Nuclear Fission Safety project 'Dose Reconstruction' is presented. A combined mechanical-chemical procedure for ground enamel sample preparation is used. The signal intensity evaluation is carried out with powder spectra simulation program. Finally, the unknown dose is evaluated individually for each sample with the additive dose method. The unknown dose is obtained by subtracting a mean native dose from the back-extrapolated dose. As an example of the capability of the ISS protocol in unknown dose evaluation, the results obtained in the framework of the 2nd International Intercomparison on EPR tooth enamel dosimetry are reported

  11. Active or passive systems? The EPR approach

    International Nuclear Information System (INIS)

    Bonhomme, N.; Py, J.P.

    1996-01-01

    In attempting to review how EPR is contemplated to meet requirements applicable to future nuclear power plants, the authors indicate where they see the markets and the corresponding unit sizes for the EPR which is a generic key factor for competitiveness. There are no reason in industrialized countries, other than USA (where the investment and amortizing practices under control by Public Utility Commission are quite particular), not to build future plants in the 1000 to 1500 MWe range. Standardization, which has been actively applied all along the French program and for the Konvoi plants, does not prevent evolution and allows to concentrate large engineering effort in smooth realization of plants and achieve actual construction and commissioning without significant delays. In order to contribute to public trust renewal, a next generation of power reactors should be fundamentally less likely to incur serious accidents. To reach this goal the best of passive and active systems must be considered without forgetting that the most important source of knowledge is construction and operating experience. Criteria to assess passive systems investigated for possible implementation in the EPR, such as simplicity of design, impact on plant operation, safety and cost, are discussed. Examples of the principal passive systems investigated are described and reasons why they have been dropped after screening through the criteria are given. (author). 11 figs

  12. Comparative study of some new EPR dosimeters

    International Nuclear Information System (INIS)

    Alzimami, K.S.; Maghraby, Ahmed M.; Bradley, D.A.

    2014-01-01

    Investigations have been made of four new radiation dosimetry EPR candidates from the same family of materials: sulfamic acid, sulfanillic acid, homotaurine, and taurine. Mass energy attenuation coefficients, mass stopping power values and the time dependence of the radiation induced radicals are compared. Also investigated are the microwave saturation behavior and the effect of applied modulation amplitude on both peak-to-peak line width (W PP ) and peak-to-peak signal height (H PP ). The dosimeters are characterized by simple spectra and stable radiation-induced radicals over reasonable durations, especially in taurine dosimeters. Sulfamic acid dosimeters possessed the highest sensitivity followed by taurine and homotaurine and sulfanillic. - Highlights: ► Several EPR dosimeters were suggested based on SO 3 − radical. ► Taurine, homotaurine, sulfanilic, and sulfamic acid all possess simple EPR spectra. ► Dosimeters were compared to each other in terms of the dosimetric point of view. ► Energy dependence curves of the selected dosimeters were compared to eachother

  13. Active or passive systems? The EPR approach

    Energy Technology Data Exchange (ETDEWEB)

    Bonhomme, N [Nuclear Power International, Cedex (France); Py, J P [FRAMATOME, Cedex (France)

    1996-12-01

    In attempting to review how EPR is contemplated to meet requirements applicable to future nuclear power plants, the authors indicate where they see the markets and the corresponding unit sizes for the EPR which is a generic key factor for competitiveness. There are no reason in industrialized countries, other than USA (where the investment and amortizing practices under control by Public Utility Commission are quite particular), not to build future plants in the 1000 to 1500 MWe range. Standardization, which has been actively applied all along the French program and for the Konvoi plants, does not prevent evolution and allows to concentrate large engineering effort in smooth realization of plants and achieve actual construction and commissioning without significant delays. In order to contribute to public trust renewal, a next generation of power reactors should be fundamentally less likely to incur serious accidents. To reach this goal the best of passive and active systems must be considered without forgetting that the most important source of knowledge is construction and operating experience. Criteria to assess passive systems investigated for possible implementation in the EPR, such as simplicity of design, impact on plant operation, safety and cost, are discussed. Examples of the principal passive systems investigated are described and reasons why they have been dropped after screening through the criteria are given. (author). 11 figs.

  14. Factors influencing EPR dosimetry in fingernails

    International Nuclear Information System (INIS)

    Dubner, D.L.; Spinella, M.R.; Bof, E.

    2010-01-01

    The technique based on the detection of ionizing radiation induced radicals by EPR in tooth enamel is an established method for the dosimetry of exposed persons in radiological emergencies. Dosimetry based on EPR spectral analysis of fingernail clippings, currently under development, has the practical advantage of the easier sample collection. A limiting factor is that overlapping the radiation induced signal (RIS), fingernails have shown the presence of two mechanically induced signals, called MIS1 and MIS2, due to elastic and plastic deformation respectively, at the time of fingernails cutting. With a water treatment, MIS1 is eliminated while MIS2 is considerably reduced. The calibration curves needed for radiation accident dosimetry should have 'universal' characteristics, ie. Represent the variability that can be found in different individuals. Early studies were directed to the analysis of factors affecting the development of such universal calibration curves. The peak to peak amplitude of the signal before and after the water treatment as well as the effect of size and number of clippings were studied. Furthermore, the interpersonal and intrapersonal variability were analyzed. Taking into account these previous studies, the optimal conditions for measurement were determined and EPR spectra of samples irradiated at different doses were used for the developing of dose-response curves. This paper presents the analysis of the results.(authors) [es

  15. Preliminary evaluation of second harmonic direct detection scheme for low-dose range in alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Chen, Felipe; Graeff, Carlos F.O.; Baffa, Oswaldo

    2002-01-01

    The usefulness of a direct detection scheme of the second harmonic (2h) overmodulated signal from irradiated alanine in EPR dosimetry was studied. For this purpose, a group of DL-alanine/paraffin cylindrical pellets was produced. The dosimeters were irradiated with a 60 Co radiotherapy gamma source with doses of 0.05, 0.1, 0.5, 1 and 5 Gy. The EPR measurements were carried out in a VARIAN-E4 spectrometer operating in X-band with optimized parameters to obtain highest amplitude signals of both harmonics. The 2h signal was detected directly at twice the modulation frequency. In preliminary results, the 2h showed some advantages over the 1h such as better resolution for doses below 1 Gy, better repeatability results and better linear behaviour in the dose range indicated. (author)

  16. Retrospective individual dosimetry using EPR of tooth enamel

    International Nuclear Information System (INIS)

    Skvortzo, V.; Ivannikov, A.; Stepanenko, V.; Wieser, A.; Bougai, A.; Brick, A.; Chumak, V.; Radchuk, V.; Repin, V.; Kirilov, V.

    1996-01-01

    The results of joint investigations (in the framework of ECP-10 program) aimed on the improvement of the sensitivity and accuracy of the procedure of dose measurement using tooth enamel EPR spectroscopy are presented. It is shown, what the sensitivity of method may be increased using special physical-chemical procedure of the enamel samples treatment, which leads to the reducing of EPR signal of organic components in enamel. Tooth diseases may have an effect on radiation sensitivity of enamel. On the basis of statistical analysis of the results of more then 2000 tooth enamel samples measurements it was shown, what tooth enamel EPR spectroscopy gives opportunity to register contribution into total dose, which is caused by natural environmental radiation and by radioactive contamination. EPR response of enamel to ultraviolet exposure is investigated and possible influences to EPR dosimetry is discussed. The correction factors for EPR dosimetry in real radiation fields are estimated

  17. Confirmation of a second EPR to be built at Penly

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    The French government has made public its decision to launch the construction of a second EPR in France. This EPR is planned to be built on the Penly site (northern region of France). EDF will manage this project but other investors like GDF-Suez are invited to participate. The construction works are planned to begin in 2012 for a commissioning in 2017. This reactor will be the fifth EPR being built in the world. (A.C.)

  18. The SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Pakarinen, J.; Papadakis, P. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J. [STFC Daresbury Laboratory, Warrington (United Kingdom)

    2014-03-15

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  19. The SAGE spectrometer

    International Nuclear Information System (INIS)

    Pakarinen, J.; Papadakis, P.; Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M.; Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D.; Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J.

    2014-01-01

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  20. The MEG positron spectrometer

    International Nuclear Information System (INIS)

    Nishiguchi, Hajime

    2007-01-01

    We have been developing an innovative spectrometer for the MEG experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment searches for a lepton flavour violating decay μ + →e + γ with a sensitivity of 10 -13 in order to explore the region predicted by supersymmetric extensions of the standard model. The MEG positron spectrometer consists of a specially designed superconducting solenoidal magnet with a highly graded field, an ultimate low-mass drift chamber system, and a precise time measuring counter system. This innovative positron spectrometer is described here focusing on the drift chamber system

  1. Solid-state EPR strategies for the structural characterization of paramagnetic NO adducts of frustrated Lewis pairs (FLPs)

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Marcos de; Magon, Claudio José [Instituto de Física de São Carlos, Universidade de São Paulo, P.O. Box 369, 13560-970 São Carlos, São Paulo (Brazil); Wiegand, Thomas [Laboratorium für Physikalische Chemie, ETH Zürich, Vladimir-Prelog-Weg 2, 8049 Zürich (Switzerland); Elmer, Lisa-Maria; Sajid, Muhammad; Kehr, Gerald; Erker, Gerhard [Organisch-Chemisches Institut, WWU Münster, Corrensstraße 40, D 48149 Münster (Germany); Eckert, Hellmut, E-mail: eckerth@uni-muenster.de [Instituto de Física de São Carlos, Universidade de São Paulo, P.O. Box 369, 13560-970 São Carlos, São Paulo (Brazil); Institut für Physikalische Chemie, WWU Münster, Corrensstrasse 30, D 48149 Münster (Germany)

    2015-03-28

    Anisotropic interactions present in three new nitroxide radicals prepared by N,N addition of NO to various borane-phosphane frustrated Lewis pairs (FLPs) have been characterized by continuous-wave (cw) and pulsed X-band EPR spectroscopies in solid FLP-hydroxylamine matrices at 100 K. Anisotropic g-tensor values and {sup 11}B, {sup 14}N, and {sup 31}P hyperfine coupling tensor components have been extracted from continuous-wave lineshape analyses, electron spin echo envelope modulation (ESEEM), and hyperfine sublevel correlation spectroscopy (HYSCORE) experiments with the help of computer simulation techniques. Suitable fitting constraints are developed on the basis of density functional theory (DFT) calculations. These calculations reveal that different from the situation in standard nitroxide radicals (TEMPO), the g-tensors are non-coincident with any of the nuclear hyperfine interaction tensors. The determination of these interaction parameters turns out to be successful, as the cw- and pulse EPR experiments are highly complementary in informational content. While the continuous-wave lineshape is largely influenced by the anisotropic hyperfine coupling to {sup 14}N and {sup 31}P, the ESEEM and HYSCORE spectra contain important information about the {sup 11}B hyperfine coupling and nuclear electric quadrupolar interaction. The set of cw- and pulsed EPR experiments, with fitting constraints developed by DFT calculations, defines an efficient strategy for the structural analysis of paramagnetic FLP adducts.

  2. EPR study on gamma-irradiated fruits dehydrated via osmosis

    Energy Technology Data Exchange (ETDEWEB)

    Yordanov, N.D. [Laboratory EPR, Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria)]. E-mail: ndyepr@bas.bg; Aleksieva, K. [Laboratory EPR, Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria)

    2007-06-15

    The shape and time stability of the electron paramagnetic resonance (EPR) spectra of non- and {gamma}-irradiated papaya, melon, cherry and fig samples dehydrated via osmosis are reported. It is shown that non-irradiated samples are generally EPR silent whereas {gamma}-irradiated exhibit 'sugar-like' EPR spectra. The recorded EPR spectra are monitored for a period of 7 months after irradiation (stored at low humidity and in the dark). The results suggest longer period of unambiguous identification of the radiation processing of osmose dehydrated fruits. Therefore, the Protocol EN 13708,2001 issued by CEN is fully applicable for the studied fruit samples.

  3. EPR study on gamma-irradiated fruits dehydrated via osmosis

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Aleksieva, K.

    2007-01-01

    The shape and time stability of the electron paramagnetic resonance (EPR) spectra of non- and γ-irradiated papaya, melon, cherry and fig samples dehydrated via osmosis are reported. It is shown that non-irradiated samples are generally EPR silent whereas γ-irradiated exhibit 'sugar-like' EPR spectra. The recorded EPR spectra are monitored for a period of 7 months after irradiation (stored at low humidity and in the dark). The results suggest longer period of unambiguous identification of the radiation processing of osmose dehydrated fruits. Therefore, the Protocol EN 13708,2001 issued by CEN is fully applicable for the studied fruit samples

  4. EPR study on gamma-irradiated fruits dehydrated via osmosis

    Science.gov (United States)

    Yordanov, N. D.; Aleksieva, K.

    2007-06-01

    The shape and time stability of the electron paramagnetic resonance (EPR) spectra of non- and γ-irradiated papaya, melon, cherry and fig samples dehydrated via osmosis are reported. It is shown that non-irradiated samples are generally EPR silent whereas γ-irradiated exhibit "sugar-like" EPR spectra. The recorded EPR spectra are monitored for a period of 7 months after irradiation (stored at low humidity and in the dark). The results suggest longer period of unambiguous identification of the radiation processing of osmose dehydrated fruits. Therefore, the Protocol EN 13708,2001 issued by CEN is fully applicable for the studied fruit samples.

  5. A web-based database for EPR centers in semiconductors

    International Nuclear Information System (INIS)

    Umeda, T.; Hagiwara, S.; Katagiri, M.; Mizuochi, N.; Isoya, J.

    2006-01-01

    We develop a web-based database system for electron paramagnetic resonance (EPR) centers in semiconductors. This database is available to anyone at http://www.kc.tsukuba.ac.jp/div-media/epr/. It currently has more than 300 records of the spin-Hamiltonian parameters for major known EPR centers. One can upload own new records to the database or can use simulation tools powered by EPR-NMR(C). Here, we describe the features and objectives of this database, and mention some future plans

  6. Identification of gamma-irradiated fruit juices by EPR spectroscopy

    International Nuclear Information System (INIS)

    Aleksieva, K.I.; Dimov, K.G.; Yordanov, N.D.

    2014-01-01

    The results of electron paramagnetic resonance (EPR) study on commercially available juices from various fruits and different fruit contents: 25%, 40%, 50%, and 100%, homemade juices, nectars and concentrated fruit syrups, before and after gamma-irradiation are reported. In order to remove water from non- and irradiated samples all juices and nectars were filtered; the solid residue was washed with alcohol and dried at room temperature. Only concentrated fruit syrups were dried for 60 min at 40 °C in a standard laboratory oven. All samples under study show a singlet EPR line with g=2.0025 before irradiation with exception of concentrated fruit syrups, which are EPR silent. Irradiation of juice samples gives rise to complex EPR spectra which gradually transferred to “cellulose-like” EPR spectrum from 25% to 100% fruit content. Concentrated fruit syrups show typical “sugar-like“ spectra due to added saccharides. All EPR spectra are characteristic and can prove radiation treatment. The fading kinetics of radiation-induced EPR signals were studied for a period of 60 days after irradiation. - Highlights: • The EPR analysis of juices, nectars and syrups proves that the sample has been irradiated. • Two sample preparation procedures were used. • The stability of the radiation induced EPR signals was studied over 2 months. • Application of European standards can be extended for irradiated juices and syrups

  7. EPR investigation of some gamma-irradiated medicines

    International Nuclear Information System (INIS)

    Aleksieva, Katerina; Yordanov, Nicola

    2016-01-01

    The results of EPR studies on three medical tablets – Galanthamine, Cytisine and Tribulus terrestris before and after gamma-irradiation are reported. Before irradiation Galanthamine and Cytisine tablets are EPR silent, whereas Tribulus terrestris show a broad singlet line with g factor 2.2084±0.002. The same spectrum is recorded after irradiation. After gamma-sterilization, however, Galanthamine and Cytisine tablets exhibit a typical EPR spectrum due to gamma induced free radicals in lactose used as an excipient. These stable free radicals can be used for identification of radiation processing for a long time after it. Key words: medical tablets, gamma-irradiation, EPR

  8. In vivo EPR dosimetry of accidental exposures to radiation: experimental results indicating the feasibility of practical use in human subjects

    International Nuclear Information System (INIS)

    Miyake, Minoru; Liu, K.J.; Walczak, T.M.; Swartz, H.M.

    2000-01-01

    Low frequency electron paramagnetic resonance (EPR) provides the potential advantage of making accurate and sensitive measurements of absorbed radiation dose in teeth in situ, i.e. without removing the teeth from the potential victim. The potential limiting factors for making such measurements are: (1) whether low frequency EPR is sufficiently sensitive to detect radiation-induced signal in human teeth; (2) whether sufficient sensitivity can be maintained under in vivo conditions. In this manuscript, we summarize results indicating that this approach is feasible. Using 1.2 GHz EPR spectroscopy, we found that the lower limit for these measurements in isolated human teeth is 0.2 Gy or lower. Measurements of radiation-induced EPR signals in the teeth of living rats were achieved with sufficient sensitivity to indicate that, when taking into consideration the larger mass of human teeth, similar measurements in human teeth in situ would provide sensitivity in the dose range for potential accidental exposures. We estimate that the current lower limit for detecting radiation doses in human teeth in situ (in vivo) is 0.5-1.0 Gy; this would be sufficient for determining if a person has been exposed to potentially life threatening doses of ionizing radiation. The limiting factor for sensitivity appears to be background signals rather than signal/noise, and there are feasible means to overcome this problem and further increase sensitivity. The additional instrumental developments required to make an effective in vivo EPR dosimetric spectrometer for the measurements in teeth in human subjects in situ, seem quite achievable

  9. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  10. Micro Plasma Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  11. Fourier Transform Spectrometer System

    Science.gov (United States)

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  12. Locations of radical species in black pepper seeds investigated by CW EPR and 9GHz EPR imaging.

    Science.gov (United States)

    Nakagawa, Kouichi; Epel, Boris

    2014-10-15

    In this study, noninvasive 9GHz electron paramagnetic resonance (EPR)-imaging and continuous wave (CW) EPR were used to investigate the locations of paramagnetic species in black pepper seeds without further irradiation. First, lithium phthalocyanine (LiPC) phantom was used to examine 9GHz EPR imaging capabilities. The 9GHz EPR-imager easily resolved the LiPC samples at a distance of ∼2mm. Then, commercially available black pepper seeds were measured. We observed signatures from three different radical species, which were assigned to stable organic radicals, Fe(3+), and Mn(2+) complexes. In addition, no EPR spectral change in the seed was observed after it was submerged in distilled H2O for 1h. The EPR and spectral-spatial EPR imaging results suggested that the three paramagnetic species were mostly located at the seed surface. Fewer radicals were found inside the seed. We demonstrated that the CW EPR and 9GHz EPR imaging were useful for the determination of the spatial distribution of paramagnetic species in various seeds. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Contribution of Harold M. Swartz to In Vivo EPR and EPR Dosimetry.

    Science.gov (United States)

    Gallez, Bernard

    2016-12-01

    In 2015, we are celebrating half a century of research in the application of Electron Paramagnetic Resonance (EPR) as a biodosimetry tool to evaluate the dose received by irradiated people. During the EPR Biodose 2015 meeting, a special session was organized to acknowledge the pioneering contribution of Harold M. (Hal) Swartz in the field. The article summarizes his main contribution in physiology and medicine. Four emerging themes have been pursued continuously along his career since its beginning: (1) radiation biology; (2) oxygen and oxidation; (3) measuring physiology in vivo; and (4) application of these measurements in clinical medicine. The common feature among all these different subjects has been the use of magnetic resonance techniques, especially EPR. In this article, you will find an impressionist portrait of Hal Swartz with the description of the 'making of' this pioneer, a time-line perspective on his career with the creation of three National Institutes of Health-funded EPR centers, a topic-oriented perspective on his career with a description of his major contributions to Science, his role as a mentor and his influence on his academic children, his active role as founder of scientific societies and organizer of scientific meetings, and the well-deserved international recognition received so far. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Contribution of Harold M. Swartz to In Vivo EPR and EPR Dosimetry

    International Nuclear Information System (INIS)

    Gallez, Bernard

    2016-01-01

    In 2015, we are celebrating half a century of research in the application of Electron Paramagnetic Resonance (EPR) as a biodosimetry tool to evaluate the dose received by irradiated people. During the EPR Biodose 2015 meeting, a special session was organized to acknowledge the pioneering contribution of Harold M. (Hal) Swartz in the field. The article summarizes his main contribution in physiology and medicine. Four emerging themes have been pursued continuously along his career since its beginning: (1) radiation biology; (2) oxygen and oxidation; (3) measuring physiology in vivo; and (4) application of these measurements in clinical medicine. The common feature among all these different subjects has been the use of magnetic resonance techniques, especially EPR. In this article, you will find an impressionist portrait of Hal Swartz with the description of the 'making of' this pioneer, a time-line perspective on his career with the creation of three National Institutes of Health-funded EPR centers, a topic-oriented perspective on his career with a description of his major contributions to Science, his role as a mentor and his influence on his academic children, his active role as founder of scientific societies and organizer of scientific meetings, and the well-deserved international recognition received so far. (author)

  15. The investigation of lithium formate hydrate, sodium dithionate and N-methyl taurine as clinical EPR dosimeters

    International Nuclear Information System (INIS)

    Lelie, S.; Hole, E.O.; Duchateau, M.; Schroeyers, W.; Schreurs, S.; Verellen, D.

    2013-01-01

    Introduction: EPR-dosimetry using L-α-alanine is an established method for measuring high doses of ionizing radiation. However, since a minimum dose of approximately 4 Gy is required to achieve sufficient low uncertainties (1–2%) for clinical application, alternative dosimeter materials are being inquired. Lithium formate (LiFo) monohydrate has been studied by several groups and has revealed several promising properties in the low dose region (<4 Gy). The fading properties, however, are somewhat unpredictable, and depend on properties not yet fully uncovered. This paper reports the results from a study of lithium formate hydrate and N-methyl taurine as potential low dose EPR dosimeters. Methods and materials: Pellet shaped dosimeters of lithium formate monohydrate, lithium formate hydrate, sodium dithionate and N-methyl taurine were produced using a manual Weber press, L-α-alanine was obtained from Harwell dosimeters and irradiated using 60 kV and 6 MV X-ray beams, and Co-60 gamma-rays to a dose of 30 Gy and dose ranges of 0.5–100 Gy and 2–20 Gy respectively. The dosimeters were measured using an Electron Paramagnetic Resonance (EPR)-spectrometer. The detector responses for 6 MV and Co-60 radiation beams, the fading behaviors and signal shape in time were investigated. Results: Lithium formate monohydrate and lithium formate hydrate are apparently associated with near identical EPR-spectra (mainly one broad line), and the same spectrum arises for all radiation energies investigated. The shape of the EPR resonance remains constant with time, but the intensities decreases, and the fading is more prominent for the monohydrate than for the hydrate. The EPR resonance associated with N-methyl taurine is more complex than the resonance associated with LiFo and it changes with time, implying radical transitions and growth. Conclusions: The study showed that lithium formate hydrate is a strong candidate for EPR dosimetry with slightly better fading characteristics

  16. EPR: what has it taught us

    International Nuclear Information System (INIS)

    Stapp, H.P.

    1985-05-01

    This symposium commemorating the fiftieth anniversary of the paper of Einstein, Podolsky, and Rosen is a fitting place to review what that work and its sequels have taught us. Prima facie, the EPR paper appears to have been exceedingly counter-productive for the following reasons: (1) The work was quickly rebutted by Bohr, and this rebuttal was apparently accepted by most workers in the field. (2) Scientists who adopted the position advocated by Bohr have produced, in the intervening fifty years, a marvelous body of useful theory, whereas those following the course suggested by EPR have produced nothing of any certified practical value. (3) It has been shown by Bell that the conclusion reached by EPR is incompatible with their assumptions. Chemists and physicists have recently begun to examine the behavior of quantum mechanical systems that are very small, yet large enough to influence their environment in ways that appreciably modify their own behavior, vis-a-vis the behavior they would have if isolated. Because these systems are neither small enough to be treated as isolated (or as residing in a classically described environment) between preparation and detection, nor large enough to be treated classically, they do not conform to the format demanded by the Copenhagen interpretation. Indeed, the behavior of these systems depends on ontological considerations that were irrelevant in the situations covered by the Copenhagen interpretation, and that were systematically ignored in that interpretation. Scientists now face the task of enlarging the scope of quantum theory to cover these new situations, and comparing the empirical consequences of various ontological assumptions. 17 refs

  17. EPR spin trapping of protein radicals

    DEFF Research Database (Denmark)

    Davies, Michael Jonathan; Hawkins, Clare Louise

    2004-01-01

    Electron paramagnetic resonance (EPR) spin trapping was originally developed to aid the detection of low-molecular-mass radicals formed in chemical systems. It has subsequently found widespread use in biology and medicine for the direct detection of radical species formed during oxidative stress...... tumbling radicals are often broad and relatively poor in distinctive features, a number of techniques have been developed that allow a wealth of information to be obtained about the nature, site, and reactions of such radicals. This article summarizes recent developments in this area and reviews selected...... examples of radical formation on proteins....

  18. E-PR technologies in political party activities

    OpenAIRE

    Tereshchuk Vitaliy Ivanovych

    2016-01-01

    The article discusses the role of the Internet as an important communicative tool in the field of political PR. The article reviews the characteristics of PR-activities on the Internet and the features of e-PR in the political sphere. Particular attention is paid to the system of political party’s e-PR tools.

  19. PropeR: a multi disciplinary EPR system

    NARCIS (Netherlands)

    van der Linden, Helma; Boers, Gerrit; Tange, Huibert; Talmon, Jan; Hasman, Arie

    2003-01-01

    This article describes the architecture of an EPR system developed for the PropeR project. This EPR system not only aims at supporting home care of stroke patients, but is also designed in such a way that it can be ported to other medical services without much effort. We will briefly describe the

  20. EPR study on tomatoes before and after gamma-irradiation

    International Nuclear Information System (INIS)

    Aleksieva, K.; Georgieva, L.; Tzvetkova, E.; Yordanov, N.D.

    2009-01-01

    The results from the EPR studies on fresh, air-dried and lyophilized tomato samples before and after gamma-irradiation are reported. Before irradiation fresh and air-dried tomatoes exhibit one singlet EPR line characterized with common g-factor of 2.0048±0.0005, whereas freeze-dried tomato does not show any EPR spectrum. After irradiation, a typical 'cellulose-like' triplet EPR spectrum appears in all samples, attributed to cellulose free radicals, generated by gamma-irradiation. It consists of intense central line with g=2.0048±0.0005 and two weak satellite lines separated ca. 3 mT left and right of it. In air-dried and lyophilized tomatoes the 'cellulose-like' EPR spectrum is superimposed by an additional partly resolved carbohydrate spectrum. Fading measurements of the radiation-induced EPR signals indicate that the intensity of the EPR spectra of air-dried and freeze-dried tomato are reduced to about 50% after 50 days, whereas those of fresh irradiated tomatoes kept at 4 o C fade completely in 15 days. The reported results unambiguously show that the presence of two satellite lines in the EPR 'cellulose-like' spectra of tomato samples can be used for identification of radiation processing.

  1. EPR and NMR spectroscopy on spin-labeled proteins

    NARCIS (Netherlands)

    Finiguerra, Michelina Giuseppina

    2011-01-01

    Spin labeling and electron paramagnetic resonance (EPR) have been employed to study structure and dynamics of proteins. The surface polarity of four single cysteine mutants of the Zn-azurin in frozen solution were studied using 275 GHz EPR (J-band), with the advantage compared to 9 GHz (X-band) and

  2. Case Studies in e-RPL and e-PR

    Science.gov (United States)

    Cameron, Roslyn; Miller, Allison

    2014-01-01

    The use of ePortfolios for recognition of prior learning (e-RPL) and for professional recognition (e-PR) is slowly gaining in popularity in the VET sector however their use is sporadic across educational sectors, disciplines, educational institutions and professions. Added to this is an array of purposes and types of e-RPL and e-PR models and…

  3. Reporting of quantitative oxygen mapping in EPR imaging

    Science.gov (United States)

    Subramanian, Sankaran; Devasahayam, Nallathamby; McMillan, Alan; Matsumoto, Shingo; Munasinghe, Jeeva P.; Saito, Keita; Mitchell, James B.; Chandramouli, Gadisetti V. R.; Krishna, Murali C.

    2012-01-01

    Oxygen maps derived from electron paramagnetic resonance spectral-spatial imaging (EPRI) are based upon the relaxivity of molecular oxygen with paramagnetic spin probes. This technique can be combined with MRI to facilitate mapping of pO 2 values in specific anatomic locations with high precision. The co-registration procedure, which matches the physical and digital dimensions of EPR and MR images, may present the pO 2 map at the higher MRI resolution, exaggerating the spatial resolution of oxygen, making it difficult to precisely distinguish hypoxic regions from normoxic regions. The latter distinction is critical in monitoring the treatment of cancer by radiation and chemotherapy, since it is well-established that hypoxic regions are three or four times more resistant to treatment compared to normoxic regions. The aim of this article is to describe pO 2 maps based on the intrinsic resolution of EPRI. A spectral parameter that affects the intrinsic spatial resolution of EPRI is the full width at half maximum (FWHM) height of the gradient-free EPR absorption line in frequency-encoded imaging. In single point imaging too, the transverse relaxation times (T2∗) limit the resolution since the signal decays by exp(-tp/T2∗) where the delay time after excitation pulse, t p, is related to the resolution. Although the spin densities of two point objects may be resolved at this separation, it is inadequate to evaluate quantitative changes of pO 2 levels since the linewidths are proportionately affected by pO 2. A spatial separation of at least twice this resolution is necessary to correctly identify a change in pO 2 level. In addition, the pO 2 values are blurred by uncertainties arising from spectral dimensions. Blurring due to noise and low resolution modulates the pO 2 levels at the boundaries of hypoxic and normoxic regions resulting in higher apparent pO 2 levels in hypoxic regions. Therefore, specification of intrinsic resolution and pO 2 uncertainties are

  4. Properties of the ammonium tartrate/EPR dosimeter

    International Nuclear Information System (INIS)

    Yordanov, N.D.; Gancheva, V.

    2004-01-01

    The EPR response of γ-irradiated ammonium tartrate on the absorbed dose of γ-rays up to 22 kGy as well as the changes in the shape of the EPR spectrum upon applied modulation amplitude and microwave power are reported. Also the possibility to use ammonium tartrate together with Mn 2+ magnetically diluted in MgO as an internal reference material is evaluated. The influence of the microwave power and the modulation amplitude on their dose response is investigated. The results show that the radiation-induced EPR spectrum of ammonium tartrate, obtained at a low microwave power is complex consisting several patterns and is more easily saturated than the Mn 2+ EPR spectrum. In this case the following settings of the EPR parameters are recommended: H mod ≤0.05 mT and 10≤P MW ≤13 mW. Using these parameters the dosimeters can be considered for use in intercomparisons

  5. On the annealing of the EPR dislocation signal in silicon

    International Nuclear Information System (INIS)

    Zolotukhin, M.N.; Kveder, V.V.; Osip'yan, Yu.A.

    1981-01-01

    The annealing kinetics of the (EPR) dislocation signal (D-centers) in silicon is studied. The disappearance of the dislocation EPR signal as a result of annealing is ascribed to rearrangement of the nuclei of the partial dislocations accompanied by pairwise ''closing'' of the broken bonds in the S=0 state. The height of the energy barrier for the rearrangement process is approximately 2 eV. A residual ''nonannealing'' EPR signal is observed in strongly deformed silicon crystals. It resembles an isotropic line with a width approximately 7.5 Oe and a g-factor approximately 2.006. It is suggested that the respective EPR centers (O-centers) are similar to the EPR centers in amorphic silicon [ru

  6. Selective saturation method for EPR dosimetry with tooth enamel

    International Nuclear Information System (INIS)

    Ignatiev, E.A.; Romanyukha, A.A.; Koshta, A.A.; Wieser, A.

    1996-01-01

    The method of selective saturation is based on the difference in the microwave (mw) power dependence of the background and radiation induced EPR components of the tooth enamel spectrum. The subtraction of the EPR spectrum recorded at low mw power from that recorded at higher mw power provides a considerable reduction of the background component in the spectrum. The resolution of the EPR spectrum could be improved 10-fold, however simultaneously the signal-to-noise ratio was found to be reduced twice. A detailed comparative study of reference samples with known absorbed doses was performed to demonstrate the advantage of the method. The application of the selective saturation method for EPR dosimetry with tooth enamel reduced the lower limit of EPR dosimetry to about 100 mGy. (author)

  7. Costing the EPR Project Using the Real Options Method

    International Nuclear Information System (INIS)

    Epaulard, Anne; Gallon, Stephane

    2001-01-01

    Real options theory makes it possible to cost investments which offer flexibility but whose returns are uncertain, such as the construction in 2000 of an EPR prototype; this prototype will enable the European pressurised-water reactor (EPR) to be used to renew EDF's nuclear power stations in 2020 (flexibility) but its economic worth will then depend on the cost of the competing gas-fired power plants (uncertain return). Options theory shows that investing in EPR technology in 2000 provides sufficient flexibility in 2020 to be considered cost-effective, even though use of EPRs is unlikely by that date. The investment made in 2000 to develop EPR technology therefore actually plays the part of an option or, in other words, insurance (against the risk of high gas prices)

  8. Deploying the advanced U.S. EPR

    International Nuclear Information System (INIS)

    Hagan, C.

    2007-01-01

    As electricity demand, clean air concerns and energy prices increase in the U.S., interest in new nuclear reactors is also on the rise. These factors - along with decades of outstanding performance of the nation's existing nuclear fleet - have contributed to a favorable market for new nuclear power in the U.S. Although no U.S. company has declared it actually will buy and build new reactors, many have actively expressed their interest through investment and regulatory interaction. The timing is also right for new reactors in terms of public perception, government policy and acceptance of the investment community. Amid this environment, the U.S. commercial power industry recently has begun pursuing new nuclear generation in earnest. AREVA, whose ongoing global market analyses indicated the need for additional baseload nuclear generation in the U.S., chose to license its EPR design to meet that need. This article will discuss the American market landscape for new nuclear and how AREVA is approaching it, present an overview of the company's U.S. EPR technology, and provide an update on the regulatory status of the design and deployment schedule. (orig.)

  9. Post-processing of EPR spectrum from dosimetric substances through filtering of Discrete Fourier Transform

    International Nuclear Information System (INIS)

    Vieira, Fabio P.B.; Bevilacqua, Joyce S.

    2014-01-01

    The use of electron paramagnetic resonance spectrometers - EPR - in radiation dosimetry is known for more than four decades. It is an important tool in the retrospective determination of doses absorbed. To estimate the dose absorbed by the sample, it is necessary to know the amplitude of the peak to peak signature of the substance in its EPR spectrum. This information can be compromised by the presence of spurious information: noise - of random and low intensity nature; and the behavior of the baseline - coming from the coupling between the resonator tube and the sample analyzed. Due to the intrinsic characteristics of the three main components of the signal, i.e. signature, noise, and baseline - the analysis in the frequency domain allows, through post-processing techniques to filter spurious information. In this work, an algorithm that retrieves the signature of a substance has been implemented. The Discrete Fourier Transform is applied to the signal and without user intervention, the noise is filtered. From the filtered signal, recovers the signature by Inverse Discrete Fourier Transform. The peak to peak amplitude, and the absorbed dose is calculated with an error of less than 1% for signals wherein the base line is linearized. Some more general cases are under investigation and with little user intervention, you can get the same error

  10. Direct detection of second harmonic and its use in alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Chen, F.; Guzman, C.S.; Graeff, C.F.O.; Baffa, O.

    2001-01-01

    In this work, the possible use of the second harmonic EPR signal from irradiated alanine for low radiation dose (∼1 Gy) was explored, aiming applications to HDR brachytherapy and teletherapy. The second harmonic signal was directly detected after overmodulation. A batch of DL-alanine/paraffin small cylindrical pellets was made. A VARIAN E-4 X-Band EPR spectrometer with optimized operation parameters like microwave power and modulation amplitude to obtain a signal with the highest amplitude was used. The modulation frequency and modulation amplitude were 100 kHz and 1.25 mT (to overmodulate the signal) respectively. The second harmonic signal was directly detected at twice the modulation frequency. One group of dosimeters was irradiated with a 192 Ir brachytherapy source and the other in a 10 MeV X-rays linear accelerator, both group at a dose range: 0.5 - 15 Gy. The second harmonic signal showed better resolution than the first harmonic one making possible a more easy localization of the signal. Moreover, for both types of radiation, the dose-response curve showed a good linear behavior for the dose range indicated. (author)

  11. Systematic review and meta-analysis of method comparison studies of Masimo pulse co-oximeters (Radical-7™ or Pronto-7™) and HemoCue® absorption spectrometers (B-Hemoglobin or 201+) with laboratory haemoglobin estimation.

    Science.gov (United States)

    Hiscock, R; Kumar, D; Simmons, S W

    2015-05-01

    We assessed agreement in haemoglobin measurement between Masimo pulse co-oximeters (Rad-7™ and Pronto-7™) and HemoCue® photometers (201+ or B-Hemoglobin) with laboratory-based determination and identified 39 relevant studies (2915 patients in Masimo group and 3084 patients in HemoCue group). In the Masimo group, the overall mean difference was -0.03 g/dl (95% prediction interval -0.30 to 0.23) and 95% limits of agreement -3.0 to 2.9 g/dl compared to 0.08 g/dl (95% prediction interval -0.04 to 0.20) and 95% limits of agreement -1.3 to 1.4 g/dl in the HemoCue group. Only B-Hemoglobin exhibited bias (0.53, 95% prediction interval 0.27 to 0.78). The overall standard deviation of difference was larger (1.42 g/dl versus 0.64 g/dl) for Masimo pulse co-oximeters compared to HemoCue photometers. Masimo devices and HemoCue 201+ both provide an unbiased, pooled estimate of laboratory haemoglobin. However, Masimo devices have lower precision and wider 95% limits of agreement than HemoCue devices. Clinicians should carefully consider these limits of agreement before basing transfusion or other clinical decisions on these point-of-care measurements alone.

  12. A convenient tuning method for NMR/NQR spectrometers by using piezoelectric resonance from quartz crystals

    International Nuclear Information System (INIS)

    Yoon, J.G.; Yu, I.S.; Kwun, S.I.

    1986-01-01

    We observe that the cw or pulse NMR/NQR spectrometer tuning can be easily and conveniently adjusted by utilizing the piezoelectric resonance signal from quartz crystal sample. For an illustration some properties of the resonance signal are shown. (Author)

  13. An EPR study of the lacquer-type bottle deposits from red wines

    International Nuclear Information System (INIS)

    Troup, G.J.; Hutton, D.R.; Pilbrow, J.R.; Hunter, C.A.; Hewitt, D.G.

    1996-01-01

    Full text: Lacquer-type deposits from 4 naturally aged red wines and one 'artificially', aged wine (by heating for 16 hrs at 84 deg C) were obtained from the Australian Wine Research Institute, Adelaide, and examined by EPR spectroscopy with a Varian E- 12 spectrometer working at ∼ 9.1 GHz The naturally aged wine deposits showed Fe 3+ in a low-symmetry site (g = 4.3), and Cu 2+ in an axial symmetry site (as deduced from the hyperfine structure) showing superhyperfine structure from N nuclei. A strong free radical signal was also present. The artificially aged wine deposit spectrum was similar, except no superhyperfine structure was present. The deposits are known to be anthocyanines cross-linked to a protein. The older the wine, the more intense was the superhyperfine structure, due to copper-amine interaction with the protein. The free radical signal is associated with the anthocyanines

  14. IN-VIVO RADIATION DOSIMETRY USING PORTABLE L BAND EPR: ON-SITE MEASUREMENT OF VOLUNTEERS IN FUKUSHIMA PREFECTURE, JAPAN

    Science.gov (United States)

    Miyake, Minoru; Nakai, Yasuhiro; Yamaguchi, Ichiro; Hirata, Hiroshi; Kunugita, Naoki; Williams, Benjamin B.; Swartz, Harold M.

    2016-01-01

    The aim of this study was to make direct measurements of the possible radiation-induced EPR signals in the teeth of volunteers who were residents in Fukushima within 80 km distance from the Fukushima Nuclear Power plant at the time of the disaster, and continued to live there for at least 3 month after the disaster. Thirty four volunteers were enrolled in this study. These measurements were made using a portable L-band EPR spectrometer, which was originally developed in the EPR Center at Dartmouth. All measurements were performed using surface loop resonators that have been specifically designed for the upper incisor teeth. Potentially these signals include not only radiation-induced signals induced by the incident but also background signals including those from prior radiation exposure from the environment and medical exposure. We demonstrated that it is feasible to transport the dosimeter to the measurement site and make valid measurements. The intensity of the signals that were obtained was not significantly above those seen in volunteers who had not had potential radiation exposures at Fukushima. PMID:27522046

  15. In-vivo radiation dosimetry using portable L band EPR: on-site measurement of volunteers in Fukushima Prefecture, Japan

    International Nuclear Information System (INIS)

    Miyake, Minoru; Nakai, Yasuhiro; Yamaguchi, Ichiro; Kunugita, Naoki; Hirata, Hiroshi; Williams, Benjamin B.; Swartz, Harold M.

    2016-01-01

    The aim of this study was to make direct measurements of the possible radiation-induced EPR signals in the teeth of volunteers who were residents in Fukushima within 80 km distance from the Fukushima Nuclear Power plant at the time of the disaster, and continued to live there for at least 3 month after the disaster. Thirty four volunteers were enrolled in this study. These measurements were made using a portable L-band EPR spectrometer, which was originally developed in the EPR Center at Dartmouth. All measurements were performed using surface loop resonators that have been specifically designed for the upper incisor teeth. Potentially these signals include not only radiation-induced signals induced by the incident but also background signals including those from prior radiation exposure from the environment and medical exposure. We demonstrated that it is feasible to transport the dosimeter to the measurement site and make valid measurements. The intensity of the signals that were obtained was not significantly above those seen in volunteers who had not had potential radiation exposures at Fukushima. (authors)

  16. EFFECT OF MICROWAVE POWER ON SHAPE OF EPR SPECTRA--APPLICATION TO EXAMINATION OF COMPLEX FREE RADICAL SYSTEM IN THERMALLY STERILIZED ACIDUM BORICUM.

    Science.gov (United States)

    Ramos, Paweł; Pieprzyca, Małgorzata; Pilawa, Barbara

    2016-01-01

    Complex free radical system in thermally sterilized acidum boricum (AB) was studied. Acidum boricum was sterilized at temperatures and times given by pharmaceutical norms: 160 degrees C and 120 min, 170 degrees C and 60 min and 180 degrees C and 30 min. The advanced spectroscopic tests were performed. The EPR spectra of free radicals were measured as the first derivatives with microwaves of 9.3 GHz frequency and magnetic modulation of 100 kHz. The Polish X-band electron paramagnetic resonance spectrometer of Radiopan (Poznań) was used. EPR lines were not observed for the nonheated AB. The broad EPR asymmetric lines were obtained for all the heated AB samples. The influence of microwave power in the range of 2.2-70 mW on the shape of EPR spectra of the heated drug samples was tested. The following asymmetry parameters: A1/A2, A1-A2, B1/B2, and B1-B2, were analyzed. The changes of these parameters with microwave power were observed. The strong dependence of shape and its parameters on microwave power proved the complex character of free radical system in thermally sterilized AB. Changes of microwave power during the detection of EPR spectra indicated complex character of free radicals in AB sterilized in hot air under all the tested conditions. Thermolysis, interactions between free radicals and interactions of free radicals with oxygen may be responsible for the complex free radicals system in thermally treated AB. Usefulness of continuous microwave saturation of EPR lines and shape analysis to examine free radicals in thermally sterilized drugs was confirmed.

  17. Cyclotrons as mass spectrometers

    International Nuclear Information System (INIS)

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  18. Miniature Raman spectrometer development

    Science.gov (United States)

    Bonvallet, Joseph; Auz, Bryan; Rodriguez, John; Olmstead, Ty

    2018-02-01

    The development of techniques to rapidly identify samples ranging from, molecule and particle imaging to detection of high explosive materials, has surged in recent years. Due to this growing want, Raman spectroscopy gives a molecular fingerprint, with no sample preparation, and can be done remotely. These systems can be small, compact, lightweight, and with a user interface that allows for easy use and sample identification. Ocean Optics Inc. has developed several systems that would meet all these end user requirements. This talk will describe the development of different Ocean Optics Inc miniature Raman spectrometers. The spectrometer on a phone (SOAP) system was designed using commercial off the shelf (COTS) components, in a rapid product development cycle. The footprint of the system measures 40x40x14 mm (LxWxH) and was coupled directly to the cell phone detector camera optics. However, it gets roughly only 40 cm-1 resolution. The Accuman system is the largest (290x220X100 mm) of the three, but uses our QEPro spectrometer and get 7-11 cm-1 resolution. Finally, the HRS-30 measuring 165x85x40 mm is a combination of the other two systems. This system uses a modified EMBED spectrometer and gets 7-12 cm-1 resolution. Each of these units uses a peak matching algorithm that then correlates the results to the pre-loaded and customizable spectral libraries.

  19. Magnetic spectrometer Grand Raiden

    International Nuclear Information System (INIS)

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  20. Microprocessor monitored Auger spectrometer

    International Nuclear Information System (INIS)

    Sapin, Michel; Ghaleb, Dominique; Pernot, Bernard.

    1982-05-01

    The operation of an Auger spectrometer, used for studying surface impurity diffusion, has been fully automatized with the help of a microprocessor. The characteristics, performance and practical use of the system are described together with the main advantage for the experimentator [fr

  1. The Omega spectrometer

    CERN Multimedia

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  2. Heat of vaporization spectrometer

    International Nuclear Information System (INIS)

    Edwards, D. Jr.

    1978-01-01

    Multilayer desorption measurements of various substances adsorbed on a stainless steel substrate are found to exhibit desorption profiles consistent with a zeroth order desorption model. The singleness of the desorption transients together with their narrow peak widths makes the technique ideally suited for a heat of vaporization spectrometer for either substance analysis or identification

  3. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  4. Thermal chopper spectrometer for the European spallation source

    DEFF Research Database (Denmark)

    Klenø, Kaspar Hewitt; Lefmann, Kim

    2011-01-01

    One of the instruments being considered for the ESS is a thermal chopper spectrometer, intended for the study of lattice vibrations and magnetic excitations. However, as the ESS will be a long pulsed source, we propose a very long instrument (180–300 m). We here present a guide system that can ac...

  5. X-ray semiconductor spectrometer with light feedback

    International Nuclear Information System (INIS)

    Zubareva, A.M.; Iliev, S.; Kushniruk, V.F.; Rykhlyuk, A.V.; Subbotin, V.G.; Kharitonov, Yu.P.

    1977-01-01

    An X-ray spectrometer with the pulse light feedback in the preamplifier has been designed. The resolution has been obtained to be 168 eV on line of 5.9 keV. The analysis of the electronics and detector contribution to the resolution has been performed

  6. Semiconductor X-ray spectrometer with light feedback

    International Nuclear Information System (INIS)

    Zubareva, A.M.; Iliev, S.; Kushniruk, V.F.; Rykhlyuk, A.V.; Subbotin, V.G.; Kharitonov, Yu.P.

    1978-01-01

    An X-ray spectrometer has been designed consisting of a preamplifier with light pulse feedback, and a Si (Li) detector. The electric(FET) circuit is given of the preamplifier designed on field effect transistors. An identification is made of the types of noises of a sink current of 7.5 mA. It is established that a significant part of the total noise comes from the detector-FET system, and white noise from leakage current in the detector. The use in the spectrometer of the preamplifier with light pulse feedback enables the white noise to be reduced to 40-45 eV with a detector leakage current of 10 -13 A. A decrease in the noise of the detector-FET system is only possible owing to the improved technology in the manufacture of FET's. The energy resolution of the spectrometer for the 5.9 keV line is 168 eV

  7. EPR design features to mitigate severe accident challenges

    International Nuclear Information System (INIS)

    Mazurkiewicz, S.M.; Fischer, M.; Bittermann, D.

    2005-01-01

    The EPR, an evolutionary pressurized water reactor (PWR), is a 4300-4500 MWth that incorporates proven technology within an optimized configuration to enhance safety. EPR was originally developed through a joint effort between Framatome ANP and Siemens by incorporating the best technological features from the French and German nuclear reactor fleets into a cost-competitive product. Commercial EPR units are currently being built in Finland at the Olkiluoto site, and planned for France at the Flamanville site. In recent months, Framatome ANP announced their intention to market the EPR units to China in response to a request for vendor bids as well as their intent to pursue design certification in the United States under 10CFR52. The EPR safety philosophy is based on a deterministic consideration of defense-in-depth complemented by probabilistic analyses. Not only is the EPR designed to prevent and mitigate design basis accidents (DBAs), it employs an extra level of safety associated with severe accident response. Therefore, as a design objective, features are included to ensure that radiological consequences are limited such that the need for stringent counter measures, such as evacuation and relocation of the nearby population, can be reasonably excluded. This paper discusses some of the innovative features of the EPR to address severe accident challenges. (author)

  8. The EPR - technology for the 3rd Millennium

    International Nuclear Information System (INIS)

    Bernstrauch, O.

    2000-01-01

    The Basic Design of the European Pressurized Water Reactor (EPR) was completed 1997 , the Basic Design Optimization Phase 1998 and the Detailed Design Phase will start in the near future. With these milestones, a new generation of PWRs is moving forward. Most of all, this is another story of a successful Franco-German cooperation. It is a rundown of the history of the EPR, before a decision is made to launch the lead-unit construction. The EPR project was launched in 1992 by Nuclear Power International (NPI), a joint company of FRAMATOME and Siemens KWU, supported by EDF and nine German electric utilities. Each step of the development of the EPR was harmonized with the Nuclear Safety Authorities both in France and Germany to reach an early approval. The EPR integrates the latest technological advances, especially in safety and operational aspects and comprises more than 30 years operating experience. Thus, the EPR combines the qualities of its predecessors, the French N4 and the German Konvoi. Presently, Siemens KWU and FRAMATOME are preparing the detailed design phase and the following construction and commissioning phase. The decision to build an EPR is not yet made either by the German electric utilities or by EdF, but it will be expected within the next months as a strong statement to follow the nuclear way and to ensure the know-how transfer. (author)

  9. Identification of gamma-irradiated fruit juices by EPR spectroscopy

    Science.gov (United States)

    Aleksieva, K. I.; Dimov, K. G.; Yordanov, N. D.

    2014-10-01

    The results of electron paramagnetic resonance (EPR) study on commercially available juices from various fruits and different fruit contents: 25%, 40%, 50%, and 100%, homemade juices, nectars and concentrated fruit syrups, before and after gamma-irradiation are reported. In order to remove water from non- and irradiated samples all juices and nectars were filtered; the solid residue was washed with alcohol and dried at room temperature. Only concentrated fruit syrups were dried for 60 min at 40 °C in a standard laboratory oven. All samples under study show a singlet EPR line with g=2.0025 before irradiation with exception of concentrated fruit syrups, which are EPR silent. Irradiation of juice samples gives rise to complex EPR spectra which gradually transferred to "cellulose-like" EPR spectrum from 25% to 100% fruit content. Concentrated fruit syrups show typical "sugar-like" spectra due to added saccharides. All EPR spectra are characteristic and can prove radiation treatment. The fading kinetics of radiation-induced EPR signals were studied for a period of 60 days after irradiation.

  10. Dosimetry in non-homogeneous media with alanine/EPR mini dosemeters and simulation with PENELOPE Monte Carlo code;Dosimetria em meios nao-homogeneos com minidosimetros de alanina/EPR e simulacao Monte Carlo com o codigo PENELOPE

    Energy Technology Data Exchange (ETDEWEB)

    Vega Ramirez, J.L.; Chen, F.; Nicolucci, P.; Baffa, O. [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2009-07-01

    The dosimetric system of L-alanine mini dosimeter and K-Band EPR spectrometer was tested for the dosimetry in non-homogeneous media through the determination of the Percentage Depth Dose (PDD) curve for a small radiation field. The alanine mini dosimeters were produced by mechanical pressure of a mixture of L-alanine (95%) and PVA (5%) to nominal dimensions of 1 mm diameter and 3 mm length and 3 - 4 mg. For detecting the EPR signal of the mini dosimeters irradiated to 25 Gy, a K-Band (24 GHz) spectrometer was used. The dosimeters were irradiated in a {sup 60}Co radiotherapy unit using 80 cm source skin distance and field sizes of 2.5 x 2.5 cm{sup 2}. The inhomogeneous phantom consisted of acrylic and cork sheets of 30 x 30 x 1 cm{sup 3}; six cork sheets were sandwiched between five and nine acrylic sheets, which were placed at the top and bottom regions respectively. PDD curves with radiographic film and PENELOPE simulation were also determined. The PDD results for alanine mini dosimeters agreed better than 5.9% with film and PENELOPE. (author)

  11. Time-of-flight mass spectrometer

    International Nuclear Information System (INIS)

    Ivanov, M.A.; Kozlov, B.N.; Mamyrin, B.A.; Shmikk, D.V.; Shebelin, V.G.

    1981-01-01

    A time-of-flight mass spectrometer containing a pulsed ion source with an electron gun and two electrodes limiting ionization range, drift space and ion acceptor, is described. To expand functional possibilities, a slot collimator of the gas stream, two quantum generators and two diaphragms for the inlet of quantum generator radiation located on both sides of the ion source, are introduced in the ion source. The above invention enables to study details of the complex interaction process of laser radiation with molecules of the gas stream, which is actual for laser isotope separation

  12. Einstein and the Quantum: The Secret Life of EPR

    Science.gov (United States)

    Fine, Arthur

    2006-05-01

    Locality, separation and entanglement -- 1930s style. Starting with Solvay 1927, we'll explore the background to the 1935 paper by Einstein, Podolsky and Rosen: how it was composed, the actual argument and principles used, and how the paper was received by Schroedinger, and others. We'll also look at Bohr's response: the extent to which Bohr connects with what Einstein was after in EPR and the extent to which EPR marks a shift in Bohr's thinking about the quantum theory. Time permitting, we will contrast EPR with Bell's theorem.

  13. EPR trademark project delivery. The value of experience

    International Nuclear Information System (INIS)

    Leverenz, Ruediger

    2013-01-01

    We are building the EPR trademark reactor fleet. Together. With four EPR trademark projects under construction in the world, AREVA has unrivalled experience in the delivery of large-scale nuclear projects, including more than a thousand lessons learned captured from Olkiluoto 3 and Flamanville 3 projects. This book of knowledge as well as the return of experience of AREVA's and EDF's teams are now being fully leveraged on ongoing projects, especially on Flamanville 3 and Taishan, and will be incorporated in all future EPR TM projects.

  14. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, I.; Huppert, M.; Wörner, H. J., E-mail: hwoerner@ethz.ch [Laboratory of Physical Chemistry, ETH Zurich, Vladimir-Prelog-Weg 2, 8093 Zurich (Switzerland); Brown, M. A. [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, Vladimir-Prelog-Weg 5, 8093 Zurich (Switzerland); Bokhoven, J. A. van [Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zurich (Switzerland); Laboratory for Catalysis and Sustainable Chemistry, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-12-15

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  15. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    International Nuclear Information System (INIS)

    Jordan, I.; Huppert, M.; Wörner, H. J.; Brown, M. A.; Bokhoven, J. A. van

    2015-01-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup

  16. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Science.gov (United States)

    Jordan, I.; Huppert, M.; Brown, M. A.; van Bokhoven, J. A.; Wörner, H. J.

    2015-12-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  17. EPR TOOTH DOSIMETRY OF SNTS AREA INHABITANTS.

    Science.gov (United States)

    Sholom, Sergey; Desrosiers, Marc; Bouville, André; Luckyanov, Nicholas; Chumak, Vadim; Simon, Steven L

    2007-07-01

    The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed "accident doses", were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine[ settlements were in the range from a few tens of mGy to approximately 100 mGy.

  18. EPR tooth dosimetry of SNTS area inhabitants

    Energy Technology Data Exchange (ETDEWEB)

    Sholom, Sergey [Scientific Center for Radiation Medicine, Melnikova str., 53, Kiev (Ukraine); Desrosiers, Marc [Ionizing Radiation Division, National Institute of Standards and Technology, Gaithersburg, MD (United States); Bouville, Andre; Luckyanov, Nicholas [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, 6120 Executive Boulevard, Bethesda, MD (United States); Chumak, Vadim [Scientific Center for Radiation Medicine, Melnikova str., 53, Kiev (Ukraine); Simon, Steven L. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, 6120 Executive Boulevard, Bethesda, MD (United States)], E-mail: ssimon@mail.nih.gov

    2007-07-15

    The determination of external dose to teeth of inhabitants of settlements near the Semipalatinsk Nuclear Test Site (SNTS) was conducted using the EPR dosimetry technique to assess radiation doses associated with exposure to radioactive fallout from the test site. In this study, tooth doses have been reconstructed for 103 persons with all studied teeth having been formed before the first nuclear test in 1949. Doses above those received from natural background radiation, termed 'accident doses', were found to lie in the range from zero to approximately 2 Gy, with one exception, a dose for one person from Semipalatinsk city was approximately 9 Gy. The variability of reconstructed doses within each of the settlements demonstrated heterogeneity of the deposited fallout as well as variations in lifestyle. The village mean external gamma doses for residents of nine settlements were in the range from a few tens of mGy to approximately 100 mGy.

  19. Radiation protection issues for EPR reactor

    International Nuclear Information System (INIS)

    Miniere, D.; Le Guen, B.; Beneteau, Y.; Le Guen, B.

    2008-01-01

    As part of the EPR (European Pressurized Reactor) project being deployed at Flamanville, EDF has pro actively made the decision to focus on radiation protection Radiation Protection aspects right from the start of the design phase, as it has done with nuclear safety. The approach adopted for managing Radiation Protection-significant activities has been to include all involved stakeholders - designers, licensee and contractor companies - in the three successive phases, starting with a survey among workers and designers, followed by a proposal review, and finally ending with the decision-making phase entrusted to an ALARA committee. The Radiation Protection target set by EDF for this new reactor is to engage in an effort of continuous improvement and optimisation, through benchmarking with the best performing plants of the fleet. The collective dose target is currently set at 0.35 Man Sv/year per unit. In addition to other aspects, efforts will focus on shortening the duration of the highest-dose jobs, with a new challenge being set for work performed in the reactor building during normal operations, the aim being to improve plant availability. The plan is for work to be performed 7 days prior to shutting down the reactor and 3 days afterwards, in order to make logistical arrangements for forthcoming jobs. Without this reduction, the estimated drop is currently 4.5% of annual dose. For this purpose, two areas have been set up in the E.P.R.'s reactor building: one no-go area for containing leaks from the primary circuit, and one accessible area for normal operations, separated from the no-go area by purpose-built ventilation equipment and facilities. To offer protection against radioactive flux (neutrons and high energy), Radiation Protection studies have resulted in the installation of a concrete floor and of nuclear shielding at the outlets of primary circuit pipes. Steam generator bunkers and pumps have also been reinforced. All these measures will ensure that the

  20. EPR by AREVA. An evolutionary reactor

    International Nuclear Information System (INIS)

    Horstmann, Marion

    2010-01-01

    The EPR development goals are as follows: 1. Evolutionary design to fully capitalize on the design, construction and operating experience based on the 86 AREVA's PWR operating worldwide; 2. Enhanced Safety compared to operating PWRs: reduce core damage frequency (CDF), accommodate severe accidents with no long-term population effect, Withstand large airplane crash (APC); 3. High availability; 4. Simplified operation and maintenance; and 5. Generation cost at least 10 % lower than 1500 MWe series in operation.The design builds on the achievements of the N4 and Konvoi reactors. The main plant data are tabulated. The PWR structure is shown as an example of the stepwise improvement. Focus of the presentation is on the construction techniques, supply chain, and project delivery. (P.A.)

  1. EPR's energy conversion system. Alstom's solutions

    International Nuclear Information System (INIS)

    Ledermann, P.

    2009-01-01

    ARABELLE steam turbines have been developed by Alstom to be used as the energy conversion system of light water reactors with high output power like the N4 PWR and the EPR. ARABELLE turbines cumulate 200.000 hours of service with a reliability ratio of 99.97 per cent. This series of slides presents the main features of the turbine including: the use of the simple flux, the very large shape of low pressure blades, the technology of welded rotors. The other main equipment like the alternator, the condenser, the moisture separator-reheaters, the circulating pumps that Alstom integrates in the energy conversion system have benefited with technological improvements that are also presented. (A.C.)

  2. EPR design tools. Integrated data processing tools

    International Nuclear Information System (INIS)

    Kern, R.

    1997-01-01

    In all technical areas, planning and design have been supported by electronic data processing for many years. New data processing tools had to be developed for the European Pressurized Water Reactor (EPR). The work to be performed was split between KWU and Framatome and laid down in the Basic Design contract. The entire plant was reduced to a logical data structure; the circuit diagrams and flowsheets of the systems were drafted, the central data pool was established, the outlines of building structures were defined, the layout of plant components was planned, and the electrical systems were documented. Also building construction engineering was supported by data processing. The tasks laid down in the Basic Design were completed as so-called milestones. Additional data processing tools also based on the central data pool are required for the phases following after the Basic Design phase, i.e Basic Design Optimization; Detailed Design; Management; Construction, and Commissioning. (orig.) [de

  3. EPR of CU+2:Mb single crystal

    International Nuclear Information System (INIS)

    Nascimento, O.R.; Ribeiro, S.C.; Bemski, G.

    1976-01-01

    Copper introduced into met-myoglobin crystals occupies various sites as indicated by EPR parameters. CU 2+ (A) is probably liganded to histidine A10, lysine A14 and asparagine GH4 (Banaszak, 1965) and shows super-hyperfine interaction with a single (imidazole) nitrogen. Cu 2+ (B) and Cu 2+ (C) correspond to other anisotropic sites described with lesser details. Cu 2+ (A) exhibits a transition to an isotropic form with a transition temperature of 40.5 0 C. This transition is indicative of a conformational change in myoglobin and could correspond to a motion of A helix away from the GH section. The transition temperature is 7 0 C higher than the previously reported (Atanasov, 1971) one for myoglobin in solution

  4. Development of a dosimeter for high doses assessment based on Alanine/EPR

    International Nuclear Information System (INIS)

    Galante, O.L.; Rodrigues, O. Jr.; Campos, L.L.

    2000-01-01

    The increasing use of radiation sources of high activity for industrial and medical applications becomes important the research and the development of detectors and dosimetric methods for quality control of the applied doses. This work presents the current stage of the research at IPEN/CNEN-SP that has as objective the development of a standard dosimetric system for high doses assessment based on the alanine as radiation detector and electron paramagnetic resonance (EPR) as measurement technique. The developed system consists of the cylindrical container built in polyethylene of high density and the detector element based on DL-alanine commercially available. For the detector preparation different binding materials such as paraffin and acetate polyvinyl solution (pva) and also the use of a polyethylene tube of low density with 3.2 mm of external diameter, 2 mm of internal diameter and 30 mm of length were tested to provide the easier preparation method and the most sensitive detector. For the alanine + paraffin detector it was used 80% of alanine and 20% of paraffin, for the alanine + pva detector it was used 70% of alanine and 30% of pva solution, and pure alanine was encapsulated, compacted and sealed in the case of the polyethylene tube. The obtained results with respect to handling, packing and construction easiness showed that the polyethylene tube presents all characteristics to obtain of a good detector element. The validation of the dosimetric system was carried out with gamma radiation of the cobalt-60 with doses in the range between 0.2 Gy to 200 kGy. Type tests such as fading, lowest detection limit, reproducibility and energy dependence of the sign EPR were performed. All measurements were carried out at room temperature using a spectrometer of electron paramagnetic resonance (EPR) Bruker model MXE. Taking into account the results obtained: linearity of the EPR signal between 10 Gy and 50 kGy, reproducibility better than 3%, low fading associated with

  5. EPR paradox, quantum nonlocality and physical reality

    International Nuclear Information System (INIS)

    Kupczynski, M

    2016-01-01

    Eighty years ago Einstein, Podolsky and Rosen demonstrated that instantaneous reduction of wave function, believed to describe completely a pair of entangled physical systems, led to EPR paradox. The paradox disappears in statistical interpretation of quantum mechanics (QM) according to which a wave function describes only an ensemble of identically prepared physical systems. QM predicts strong correlations between outcomes of measurements performed on different members of EPR pairs in far-away locations. Searching for an intuitive explanation of these correlations John Bell analysed so called local realistic hidden variable models and proved that correlations consistent with these models satisfy Bell inequalities which are violated by some predictions of QM and by experimental data. Several different local models were constructed and inequalities proven. Some eminent physicists concluded that Nature is definitely nonlocal and that it is acting according to a law of nonlocal randomness. According to these law perfectly random, but strongly correlated events, can be produced at the same time in far away locations and a local and causal explanation of their occurrence cannot be given. We strongly disagree with this conclusion and we prove the contrary by analysing in detail some influential finite sample proofs of Bell and CHSH inequalities and so called Quantum Randi Challenges. We also show how one can win so called Bell's game without violating locality of Nature. Nonlocal randomness is inconsistent with local quantum field theory, with standard model in elementary particle physics and with causal laws and adaptive dynamics prevailing in the surrounding us world. The experimental violation of Bell-type inequalities does not prove the nonlocality of Nature but it only confirms a contextual character of quantum observables and gives a strong argument against counterfactual definiteness and against a point of view according to which experimental outcomes are

  6. EPR paradox, quantum nonlocality and physical reality

    Science.gov (United States)

    Kupczynski, M.

    2016-03-01

    Eighty years ago Einstein, Podolsky and Rosen demonstrated that instantaneous reduction of wave function, believed to describe completely a pair of entangled physical systems, led to EPR paradox. The paradox disappears in statistical interpretation of quantum mechanics (QM) according to which a wave function describes only an ensemble of identically prepared physical systems. QM predicts strong correlations between outcomes of measurements performed on different members of EPR pairs in far-away locations. Searching for an intuitive explanation of these correlations John Bell analysed so called local realistic hidden variable models and proved that correlations consistent with these models satisfy Bell inequalities which are violated by some predictions of QM and by experimental data. Several different local models were constructed and inequalities proven. Some eminent physicists concluded that Nature is definitely nonlocal and that it is acting according to a law of nonlocal randomness. According to these law perfectly random, but strongly correlated events, can be produced at the same time in far away locations and a local and causal explanation of their occurrence cannot be given. We strongly disagree with this conclusion and we prove the contrary by analysing in detail some influential finite sample proofs of Bell and CHSH inequalities and so called Quantum Randi Challenges. We also show how one can win so called Bell's game without violating locality of Nature. Nonlocal randomness is inconsistent with local quantum field theory, with standard model in elementary particle physics and with causal laws and adaptive dynamics prevailing in the surrounding us world. The experimental violation of Bell-type inequalities does not prove the nonlocality of Nature but it only confirms a contextual character of quantum observables and gives a strong argument against counterfactual definiteness and against a point of view according to which experimental outcomes are produced

  7. Dosimetry in non-homogeneous media with alanine/EPR mini dosemeters and simulation with PENELOPE Monte Carlo code

    International Nuclear Information System (INIS)

    Vega Ramirez, J.L.; Chen, F.; Nicolucci, P.; Baffa, O.

    2009-01-01

    The dosimetric system of L-alanine mini dosimeter and K-Band EPR spectrometer was tested for the dosimetry in non-homogeneous media through the determination of the Percentage Depth Dose (PDD) curve for a small radiation field. The alanine mini dosimeters were produced by mechanical pressure of a mixture of L-alanine (95%) and PVA (5%) to nominal dimensions of 1 mm diameter and 3 mm length and 3 - 4 mg. For detecting the EPR signal of the mini dosimeters irradiated to 25 Gy, a K-Band (24 GHz) spectrometer was used. The dosimeters were irradiated in a 60 Co radiotherapy unit using 80 cm source skin distance and field sizes of 2.5 x 2.5 cm 2 . The inhomogeneous phantom consisted of acrylic and cork sheets of 30 x 30 x 1 cm 3 ; six cork sheets were sandwiched between five and nine acrylic sheets, which were placed at the top and bottom regions respectively. PDD curves with radiographic film and PENELOPE simulation were also determined. The PDD results for alanine mini dosimeters agreed better than 5.9% with film and PENELOPE. (author)

  8. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  9. The OPERA magnetic spectrometer

    CERN Document Server

    Ambrosio, M; Dusini, S; Dulach, B; Fanin, C; Felici, G; Corso, F D; Garfagnini, A; Grianti, F; Gustavino, C; Monacelli, P; Paoloni, A; Stanco, L; Spinetti, M; Terranova, F; Votano, L

    2004-01-01

    The OPERA neutrino oscillation experiment foresees the construction of two magnetized iron spectrometers located after the lead-nuclear emulsion targets. The magnet is made up of two vertical walls of rectangular cross section connected by return yokes. The particle trajectories are measured by high precision drift tubes located before and after the arms of the magnet. Moreover, the magnet steel is instrumented with Resistive Plate Chambers that ease pattern recognition and allow a calorimetric measurement of the hadronic showers. In this paper we review the construction of the spectrometers. In particular, we describe the results obtained from the magnet and RPC prototypes and the installation of the final apparatus at the Gran Sasso laboratories. We discuss the mechanical and magnetic properties of the steel and the techniques employed to calibrate the field in the bulk of the magnet. Moreover, results of the tests and issues concerning the mass production of the Resistive Plate Chambers are reported. Final...

  10. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  11. Magnetic spectrometer control system

    International Nuclear Information System (INIS)

    Lecca, L.A.; Di Paolo, Hugo; Fernandez Niello, Jorge O.; Marti, Guillermo V; Pacheco, Alberto J.; Ramirez, Marcelo

    2003-01-01

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  12. Polarized neutron spectrometer

    International Nuclear Information System (INIS)

    Abov, Yu.G.; Novitskij, V.V.; Alfimenkov, V.P.; Galinskij, E.M.; Mareev, Yu.D.; Pikel'ner, L.B.; Chernikov, A.N.; Lason', L.; Tsulaya, V.M.; Tsulaya, M.I.

    2000-01-01

    The polarized neutron spectrometer, intended for studying the interaction of polarized neutrons with nuclei and condensed media in the area of energies from thermal up to several electron-volt, is developed at the IBR-2 reactor (JINR, Dubna). Diffraction on the Co(92%)-Fe(8%) magnetized monocrystals is used for the neutron polarization and polarization analysis. The neutron polarization within the whole energy range equals ∼ 95% [ru

  13. Pulse Generator

    Science.gov (United States)

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  14. EPR detection of foods preserved with ionizing radiation

    Science.gov (United States)

    Stachowicz, W.; Burlinska, G.; Michalik, J.

    1998-06-01

    The applicability of the epr technique for the detection of dried vegetables, mushrooms, some spices, flavour additives and some condiments preserved with ionizing radiation is discussed. The epr signals recorded after exposure to gamma rays and to beams of 10 MeV electrons from linac are stable, intense and specific enough as compared with those observed with nonirradiated samples and could be used for the detection of irradiation. However, stability of radiation induced epr signals produced in these foods depends on storage condition. No differences in shapes (spectral parameters) and intensities of the epr spectra recorded with samples exposed to the same doses of gamma rays ( 60Co) and 10 MeV electrons were observed

  15. Software for evaluation of EPR-dosimetry performance

    International Nuclear Information System (INIS)

    Shishkina, E.A.; Timofeev, Yu.S.; Ivanov, D.V.

    2014-01-01

    Electron paramagnetic resonance (EPR) with tooth enamel is a method extensively used for retrospective external dosimetry. Different research groups apply different equipment, sample preparation procedures and spectrum processing algorithms for EPR dosimetry. A uniform algorithm for description and comparison of performances was designed and implemented in a new computer code. The aim of the paper is to introduce the new software 'EPR-dosimetry performance'. The computer code is a user-friendly tool for providing a full description of method-specific capabilities of EPR tooth dosimetry, from metrological characteristics to practical limitations in applications. The software designed for scientists and engineers has several applications, including support of method calibration by evaluation of calibration parameters, evaluation of critical value and detection limit for registration of radiation-induced signal amplitude, estimation of critical value and detection limit for dose evaluation, estimation of minimal detectable value for anthropogenic dose assessment and description of method uncertainty. (authors)

  16. Trichloroethylene Radicals: An EPR/SPIN Trapping Study

    National Research Council Canada - National Science Library

    Steel-Goodwin, Linda

    1995-01-01

    .... As part of the process to develop environmental and health effects criteria for base clean-up the initial radicals produced by TCE were studied by electron paramagnetic resonance spectroscopy (EPR...

  17. Reconfiguring Cooperative Work by Visualizing EPR on Large Projected Screens

    DEFF Research Database (Denmark)

    Simonsen, Jesper

    Simonsen, J. (2006): Reconfiguring Cooperative Work by Visualizing EPR on Large Projected Screens, Paper presented at the PDC 2006 workshop on: Reconfiguring Healthcare: Issues in Computer Supported Cooperative Work in Healthcare Environments. Participatory Design Conference, Trento, Italy, August...

  18. EPR spectroscopy of complex biological iron-sulfur systems.

    Science.gov (United States)

    Hagen, Wilfred R

    2018-02-21

    From the very first discovery of biological iron-sulfur clusters with EPR, the spectroscopy has been used to study not only purified proteins but also complex systems such as respiratory complexes, membrane particles and, later, whole cells. In recent times, the emphasis of iron-sulfur biochemistry has moved from characterization of individual proteins to the systems biology of iron-sulfur biosynthesis, regulation, degradation, and implications for human health. Although this move would suggest a blossoming of System-EPR as a specific, non-invasive monitor of Fe/S (dys)homeostasis in whole cells, a review of the literature reveals limited success possibly due to technical difficulties in adherence to EPR spectroscopic and biochemical standards. In an attempt to boost application of System-EPR the required boundary conditions and their practical applications are explicitly and comprehensively formulated.

  19. Which Parts of a Clinical Process EPR Needs Special Configuration

    DEFF Research Database (Denmark)

    Barlach, Anders; Simonsen, Jesper

    2007-01-01

    Subject: Which parts of an electronic patient record (EPR) can initially form a stable standard solution to be used by all clinicians? And which parts of an EPR can we predict needs initial as well as on-going re-configuration to meet the needs from diverse medical specialties. Purpose: To analyze...... which screen types in a clinical process that can be standard configured and which are subject to initial as well as on-going re-configuration. Methods and results: A pilot-project implementing a fully functional clinical process EPR was configured and used at a neurological ward, replacing all paper...... records 24/7. The analysis characterizes the different types of screens, a total of 243 included in the EPR solution. All screens have been extracted from the application and analyzed for changes – in total 222 changes. Discussion and conclusion: Most screens (87%) are very stable. Few (13%) are subjected...

  20. Experimental EPR-steering using Bell-local states

    Science.gov (United States)

    Saunders, D. J.; Jones, S. J.; Wiseman, H. M.; Pryde, G. J.

    2010-11-01

    The concept of `steering' was introduced in 1935 by Schrödinger as a generalization of the EPR (Einstein-Podolsky-Rosen) paradox. It has recently been formalized as a quantum-information task with arbitrary bipartite states and measurements, for which the existence of entanglement is necessary but not sufficient. Previous experiments in this area have been restricted to an approach that followed the original EPR argument in considering only two different measurement settings per side. Here we demonstrate experimentally that EPR-steering occurs for mixed entangled states that are Bell local (that is, that cannot possibly demonstrate Bell non-locality). Unlike the case of Bell inequalities, increasing the number of measurement settings beyond two-we use up to six-significantly increases the robustness of the EPR-steering phenomenon to noise.

  1. EPR detection of foods preserved with ionizing radiation

    International Nuclear Information System (INIS)

    Stachowicz, W.; Burlinska, G.; Michalik, J.

    1998-01-01

    The applicability of the epr technique for the detection of dried vegetables, mushrooms, some spices, flavour additives and some condiments preserved with ionizing radiation is discussed. The epr signals recorded after exposure to gamma rays and to the beams of 10 MeV electrons from linac are stable, intense and specific enough as compared with those observed with nonirradiated samples and could be used for the detection of irradiation. However, stability of radiation induced epr signals produced in these foods depends on storage condition. No differences in shapes (spectral parameters) and intensities of the epr spectra recorded with samples exposed to the same doses of gamma rays ( 60 Co) and 10 MeV electrons were observed

  2. Decomposition of spectra in EPR dosimetry using the matrix method

    International Nuclear Information System (INIS)

    Sholom, S.V.; Chumak, V.V.

    2003-01-01

    The matrix method of EPR spectra decomposition is developed and adapted for routine application in retrospective EPR dosimetry with teeth. According to this method, the initial EPR spectra are decomposed (using methods of matrix algebra) into several reference components (reference matrices) that are specific for each material. Proposed procedure has been tested on the example of tooth enamel. Reference spectra were a spectrum of an empty sample tube and three standard signals of enamel (two at g=2.0045, both for the native signal and one at g perpendicular =2.0018, g parallel =1.9973 for the dosimetric signal). Values of dosimetric signals obtained using the given method have been compared with data obtained by manual manipulation of spectra, and good coincidence was observed. This allows considering the proposed method as potent for application in routine EPR dosimetry

  3. EPR of radiation defects in lithium-oxyfluoride glass ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Fedotovs, A; Rogulis, U; Sarakovskis, A; Dimitrocenko, L, E-mail: andris-f@navigator.l [Institute of Solid State Physics, University of Latvia, Kengaraga st. 8, LV-1063, Riga (Latvia)

    2010-11-01

    We studied oxyfluoride composites based on lithium silicate glasses with yttrium fluorides and rare-earth dopants. The electron paramagnetic resonance (EPR) has been used to obtain information about radiation induced defects in these materials. Spectra have been measured before and after X-ray irradiation at room temperature and at liquid nitrogen temperature. Fluoride crystallites within samples were created by means of thermal treatment at specific temperatures. EPR spectra of radiation induced defects in oxyfluoride glass ceramics, in which crystallites have not been yet created, show no explicit hfs interaction of fluorine nuclei. However, in glass ceramics, which already contains fluoride crystallites, the hfs characteristic to fluorine nuclei appears in the EPR spectra. EPR hyperfine structure could be explained within a model of an F-type centre in YF{sub 3} crystalline phase.

  4. EPR of radiation defects in lithium-oxyfluoride glass ceramics

    Science.gov (United States)

    Fedotovs, A.; Rogulis, U.; Sarakovskis, A.; Dimitrocenko, L.

    2010-11-01

    We studied oxyfluoride composites based on lithium silicate glasses with yttrium fluorides and rare-earth dopants. The electron paramagnetic resonance (EPR) has been used to obtain information about radiation induced defects in these materials. Spectra have been measured before and after X-ray irradiation at room temperature and at liquid nitrogen temperature. Fluoride crystallites within samples were created by means of thermal treatment at specific temperatures. EPR spectra of radiation induced defects in oxyfluoride glass ceramics, in which crystallites have not been yet created, show no explicit hfs interaction of fluorine nuclei. However, in glass ceramics, which already contains fluoride crystallites, the hfs characteristic to fluorine nuclei appears in the EPR spectra. EPR hyperfine structure could be explained within a model of an F-type centre in YF3 crystalline phase.

  5. Reconstructing Bohr's Reply to EPR in Algebraic Quantum Theory

    Science.gov (United States)

    Ozawa, Masanao; Kitajima, Yuichiro

    2012-04-01

    Halvorson and Clifton have given a mathematical reconstruction of Bohr's reply to Einstein, Podolsky and Rosen (EPR), and argued that this reply is dictated by the two requirements of classicality and objectivity for the description of experimental data, by proving consistency between their objectivity requirement and a contextualized version of the EPR reality criterion which had been introduced by Howard in his earlier analysis of Bohr's reply. In the present paper, we generalize the above consistency theorem, with a rather elementary proof, to a general formulation of EPR states applicable to both non-relativistic quantum mechanics and algebraic quantum field theory; and we clarify the elements of reality in EPR states in terms of Bohr's requirements of classicality and objectivity, in a general formulation of algebraic quantum theory.

  6. EPR detection of foods preserved with ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W.; Burlinska, G.; Michalik, J

    1998-06-01

    The applicability of the epr technique for the detection of dried vegetables, mushrooms, some spices, flavour additives and some condiments preserved with ionizing radiation is discussed. The epr signals recorded after exposure to gamma rays and to the beams of 10 MeV electrons from linac are stable, intense and specific enough as compared with those observed with nonirradiated samples and could be used for the detection of irradiation. However, stability of radiation induced epr signals produced in these foods depends on storage condition. No differences in shapes (spectral parameters) and intensities of the epr spectra recorded with samples exposed to the same doses of gamma rays ({sup 60}Co) and 10 MeV electrons were observed.

  7. Development of Neutron Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hee; Lee, J. S.; Seong, B. S. (and others)

    2007-06-15

    Neutron spectrometers which are used in the basic researches such as physics, chemistry and materials science and applied in the industry were developed at the horizontal beam port of HANARO reactor. In addition, the development of core components for neutron scattering and the upgrade of existing facilities are also performed. The vertical neutron reflectometer was fabricated and installed at ST3 beam port. The performance test of the reflectometer was completed and the reflectometer was opened to users. The several core parts and options were added in the polarized neutron spectrometer. The horizontal neutron reflectometer from Brookhaven National Laboratory was moved to HANARO and installed, and the performance of the reflectometer was examined. The HIPD was developed and the performance test was completed. The base shielding for TAS was fabricated. The soller collimator, Cu mosaic monochromator, Si BPC monochromator and position sensitive detector were developed and applied in the neutron spectrometer as part of core component development activities. In addition, the sputtering machine for mirror device are fabricated and the neutron mirror is made using the sputtering machine. The FCD was upgraded and the performance of the FCD are improved over the factor of 10. The integration and upgrade of the neutron detection system were also performed.

  8. Most advanced HTP fuel assembly design for EPR

    International Nuclear Information System (INIS)

    Francillon, Eric; Kiehlmann, Horst-Dieter

    2006-01-01

    End 2003, the Finnish electricity utility Teollisuuden Voima Oy (TVO) signed the contract for building an EPR in Olkiluoto (Finland). Mid 2004, the French electricity utility EDF selected an EPR to be built in France. In 2005, Framatome ANP, an AREVA and Siemens company, announced that they will be pursuing a design certification in the U.S. The EPR development is based on the latest PWR product lines of former Framatome (N4) and Siemens Nuklear (Konvoi). As an introductory part, different aspects of the EPR core characteristics connected to fuel assembly design are presented. It includes means of ensuring reactivity control like hybrid AIC/B4C control rod absorbers and gadolinium as burnable absorber integrated in fuel rods, and specific options for in-core instrumentation, such as Aeroball type instrumentation. Then the design requirements for the EPR fuel assembly are presented in term of very high burnup capacity, rod cladding and fuel assembly reliability. Framatome ANP fuel assembly product characteristics meeting these requirements are then described. EPR fuel assembly design characteristics benefit from the experience feedback of the latest fuel assembly products designed within Framatome ANP, leading to resistance to assembly deformation, high fuel rod restraint and prevention of handling hazards. EPR fuel assembly design features the best components composing the cornerstones of the upgraded family of fuel assemblies that FRAMATOME ANP proposes today. This family is based on a set of common characteristics and associated features, which include the HMP grid as bottom end spacer, the MONOBLOC guide tube and the Robust FUELGUARD as lower tie plate, the use of the M5 Alloy, as cladding and structure material. This fully re-crystallized, ternary Zr-Nb-O alloy produces radically improved in-reactor corrosion, very low hydrogen uptake and growth and an excellent creep behavior, which are described there. EPR fuel assembly description also includes fuel rod

  9. Extension of the calibration of an NE-213 liquid scintillator based pulse height response spectrometer up to 18 MeV neutron energy and leakage spectrum measurements on bismuth at 8 MeV and 18 MeV neutron energies

    International Nuclear Information System (INIS)

    Fenyvesi, A.; Valastyan, I.; Olah, L.; Csikai, J.; Plompen, A.; Jaime, R.; Loevestam, G.; Semkova, V.

    2011-01-01

    Monoenergetic neutrons were produced at the Van de Graaff accelerator of the EC-JRC-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium). An air-jet cooled D_2-gas target (1.2 bar, ΔE_d = 448 keV) was bombarded with E_d =4976 keV deuterons to produce neutrons up to E_n = 8 MeV energy via the D(d,n)"3He reaction. Higher energy neutrons up to E_n = 18 MeV were produced via the T(d,n)"4He reaction by bombarding a TiT target with E_d =1968 keV deuterons. Pulse height spectra were measured at different neutron energies from E_n = 8 MeV up to E_n = 18 MeV with the NE-213 liquid scintillator based Pulse Height Response Spectrometer (PHRS) of UD-IEP. The energy calibration of the PHRS system has been extended up to E_n = 18 MeV. Pulse height spectra induced by gamma photons have been simulated by the GRESP7 code. Neutron induced pulse height spectra have been simulated by the NRESP7 and MCNP-POLIMI codes. Comparison of the results of measurements and simulations enables the improvement of the parameter set of the function used by us to describe the light output dependence of the resolution of the PHRS system at light outputs of L > 2 light units. Also, it has been shown that the derivation method for unfolding neutron spectra from measured pulse height spectra performs well when relative measurements are done up to E_n = 18 MeV neutron energy. For matrix unfolding purposes, the NRESP7 code has to be preferred to calculate the pulse height response matrix of the PHRS system. Leakage spectra of neutrons behind bismuth slabs of different thicknesses have been measured with the PHRS system by using monoenergetic neutrons. The maximum slab thickness was d = 14 cm. Simulations of the measurements have been carried out with the MCNP-4c code. The necessary nuclear cross-sections were taken from the from the ENDF/B-VII and JEFF.3.1 data libraries. For both libraries, the agreement of measured and simulated neutron spectra is good for the 5 MeV ≤ En ≤ 18 Me

  10. Emergency EPR and OSL dosimetry with table vitamins and minerals.

    Science.gov (United States)

    Sholom, S; McKeever, S W S

    2016-12-01

    Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated prominent OSL signals after exposure to ionizing radiation doses. Basic dosimetric properties of the radiation-sensitive substances were studied, namely dose response, fading of the EPR or OSL signals and values of minimum measurable doses (MMDs). For EPR-sensitive samples, the EPR signal is converted into units of dose using a linear dose response and correcting for fading using the measured fading dependence. For OSL-sensitive materials, a multi-aliquot, enhanced-temperature protocol was developed to avoid the problem of sample sensitization and to minimize the influence of signal fading. The sample dose in this case is also evaluated using the dose response and fading curves. MMDs of the EPR-sensitive samples were below 2 Gy while those of the OSL-sensitive materials were below 500 mGy as long as the samples are analyzed within 1 week after exposure. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Correlations between the particles in the EPR-paradox

    Energy Technology Data Exchange (ETDEWEB)

    Treder, H.J. (Akademie der Wissenschaften der DDR, Potsdam-Babelsberg. Einstein-Laboratorium fuer Theoretische Physik)

    1984-03-01

    The Einstein-Podolsky-Rosen 'gedanken-experiment' does not imply non-local interactions or an 'action-at-a-distance'. Contrary, the EPR proves the measurements at one particle does not have influences at canonical variables of the other particles if the quantum-mechanical commutation relations are true. But, the EPR implies correlations between the particles which come in by 'subjective knowledge'. These correlations are a priori informations about the relative motion or, complementarily, about the motion of the center of mass. The impression of an action-at-a-distance is produced by the use of usual particle coordinates in the EPR-arrangements. The discussion of the Einstein-Podolsky-Rosen 'gedanken-experiment' (EPR) has been going on over fifty years. Einstein, Podolsky, and Rosen formulated their famous paradox in 1935, and in the discussion between N. Bohr (1935, 1949) and Einstein (1936, 1948); A. Einstein (1948) made his point that the EPR implied an 'action-at-a-distance' for quantum-mechanical particles (without obvious classical interactions). His argument is the starting point for the recent discussion about EPR and causality (see A. Aspect 1981).

  12. EPR study on non- and gamma-irradiated herbal pills

    International Nuclear Information System (INIS)

    Aleksieva, K.; Lagunov, O.; Dimov, K.; Yordanov, N.D.

    2011-01-01

    The results of EPR studies on herbal pills of marigold, hawthorn, yarrow, common balm, tutsan, nettle and thyme before and after gamma-irradiation are reported. Before irradiation all samples exhibit one weak singlet EPR line with a g-factor of 2.0048±0.0005. After irradiation herbal pills could be separated in two groups according to their EPR spectra. Radiation-induced free radicals in pills of marigold, yarrow, nettle, tutsan and thyme could be attributed mainly to saccharide excipients. Tablets of hawthorn and common balm show 'cellulose-like' EPR spectrum, superimposed on partly resolved carbohydrate spectrum, due to the active part (herb) and inulin, which is present in the pills as an excipient. Fading study of the radiation-induced EPR signals confirms that sugar radicals are more stable than cellulose species. The reported results show that the presence of characteristic EPR spectra of herbal pills due to excipients or active part can be used as unambiguous proof of radiation processing within 35 or more days after irradiation.

  13. EPR study on non- and gamma-irradiated herbal pills

    Energy Technology Data Exchange (ETDEWEB)

    Aleksieva, K., E-mail: katerina_bas@abv.b [Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria); Lagunov, O. [Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria); Dimov, K. [Institute of Cryobiology and Food Technologies, 1162 Sofia (Bulgaria); Yordanov, N.D. [Institute of Catalysis, Bulgarian Academy of Sciences, 1113 Sofia (Bulgaria)

    2011-06-15

    The results of EPR studies on herbal pills of marigold, hawthorn, yarrow, common balm, tutsan, nettle and thyme before and after gamma-irradiation are reported. Before irradiation all samples exhibit one weak singlet EPR line with a g-factor of 2.0048{+-}0.0005. After irradiation herbal pills could be separated in two groups according to their EPR spectra. Radiation-induced free radicals in pills of marigold, yarrow, nettle, tutsan and thyme could be attributed mainly to saccharide excipients. Tablets of hawthorn and common balm show 'cellulose-like' EPR spectrum, superimposed on partly resolved carbohydrate spectrum, due to the active part (herb) and inulin, which is present in the pills as an excipient. Fading study of the radiation-induced EPR signals confirms that sugar radicals are more stable than cellulose species. The reported results show that the presence of characteristic EPR spectra of herbal pills due to excipients or active part can be used as unambiguous proof of radiation processing within 35 or more days after irradiation.

  14. EPR study on non- and gamma-irradiated herbal pills

    Science.gov (United States)

    Aleksieva, K.; Lagunov, O.; Dimov, K.; Yordanov, N. D.

    2011-06-01

    The results of EPR studies on herbal pills of marigold, hawthorn, yarrow, common balm, tutsan, nettle and thyme before and after gamma-irradiation are reported. Before irradiation all samples exhibit one weak singlet EPR line with a g-factor of 2.0048±0.0005. After irradiation herbal pills could be separated in two groups according to their EPR spectra. Radiation-induced free radicals in pills of marigold, yarrow, nettle, tutsan and thyme could be attributed mainly to saccharide excipients. Tablets of hawthorn and common balm show "cellulose-like" EPR spectrum, superimposed on partly resolved carbohydrate spectrum, due to the active part (herb) and inulin, which is present in the pills as an excipient. Fading study of the radiation-induced EPR signals confirms that sugar radicals are more stable than cellulose species. The reported results show that the presence of characteristic EPR spectra of herbal pills due to excipients or active part can be used as unambiguous proof of radiation processing within 35 or more days after irradiation.

  15. What Happened with Spectrometer Magnet 2B

    International Nuclear Information System (INIS)

    Green, Michael A.

    2010-01-01

    The spectrometer solenoid is supposed to be the first magnets installed in MICE (1)-(4). This report described what happened during the test of the MICE spectrometer solenoid 2B. First, the report describes the temperatures in the magnet, the cooler top plate and the shield during the run where the magnet quenched at 258 A. During this quench, a lead between the bottom of the HTS leads and the diode bank burned out causing the magnet to quench. Second, three methods for measuring the net heat flow into the cold mass are described. Third, there is a discussion of possible resistive heating in the HTS leads between liquid helium temperature and the copper plate, which is at about 50 K. Fourth, there is a discussion of the measured first stage heat loads in the magnet, when there is no current in the magnet. The first stage heat load calculations are based on knowing the first stage temperatures of the three two-stage pulse tube coolers and the single stage GM cooler. Fifth, the estimated heat load to the first stage when the magnet has current in it is discussed. Sixth, there is a comparison of the stage 1 heat loads in magnet 1A (5), magnet 2A (6), and magnet 2B (7). Finally there is a discussion of recommended changes for improving the spectrometer solenoids so that the coolers can keep them cold.

  16. Electron paramagnetic resonance (EPR) in characterization of rocks and minerals

    Energy Technology Data Exchange (ETDEWEB)

    Valezi, D.F.; Mauro, E. di [Universidade Estadual de Londrina (UEL), PR (Brazil). Centro de Ciencias Exatas. Lab. de Fluorescencia e Ressonaancia Paramagnetica Eletronica (LAFLURPE); Zaia, D.A.M.; Carneiro, C.E.A. [Universidade Estadual de Londrina (UEL), PR (Brazil). Centro de Ciencias Exatas. Dept. de Quimica; Costa, A.C.S. da [Universidade Estadual de Maringa (UEM), PR (Brazil). Centro de Ciencias Agrarias. Dept. de Agronomia

    2011-07-01

    Full text. his work is based on the study of several stones and minerals from the Parana state, Brazil. They were analyzed by the Electron Paramagnetic Resonance (EPR) technique. The measurements were made on a spectrometer JEOL (JES-PE-3X), operating on X-band and at room temperature, with the exception of the mineral Goethite, which was measured with temperature variation. In all the samples were determined spectroscopic factors (or g factor) and line widths of paramagnetic species. A great number of the samples showed in their spectra, the presence of iron complexes. Phyllite and shale showed a resonance signal with approximately g = 2, and line width with about 1000 Gauss, which indicates the presence of the hematite mineral hematite in these rocks. Shale and coal samples showed the presence of free radical, it was identified as a very intense signal, centered at about g = 2.003. Phyllite sample showed in its spectra a resonance signal between the third and fourth line of the g marker (Mg O:Mn{sup 2+}) used in the measurements, and also a signal at g = 4.3, these characteristics may indicate the presence of Kaolinite in the sample. Limestone showed a signal with line width of about 600 Gauss, centered around g = 2, this signal is probably due to a mixture of ferrihydrite and some other compound, besides the presence of manganese, displaying a spectra with its six peculiar lines, due to hyperfine splitting. The two different types of limestone presented a overlap of two distinct spectra lines for the manganese, in the first limestone sample, rich in calcite, the existence of these different spectra is a result of the manganese substitution in a single site with different orientations of the calcite; the other limestone sample, this one abundant in dolomite, the existence of these different spectra is the result of the manganese substitution in different dolomite sites, taking the place of calcium and or of the magnesium. Now, we are focusing our research in the

  17. A low-cost spectrometer for NMR measurements in the Earth's magnetic field

    International Nuclear Information System (INIS)

    Michal, Carl A

    2010-01-01

    We describe and demonstrate an inexpensive, easy-to-build, portable spectrometer for nuclear magnetic resonance measurements in the Earth's magnetic field. The spectrometer is based upon a widely available inexpensive microcontroller, which acts as a pulse programmer, audio-frequency synthesizer and digitizer, replacing what are typically the most expensive specialized components of the system. The microcontroller provides the capability to execute arbitrarily long and complicated sequences of phase-coherent, phase-modulated excitation pulses and acquire data sets of unlimited duration. Suitably packaged, the spectrometer is amenable to measurements in the research lab, in the field or in the teaching lab. The choice of components was heavily weighted by cost and availability, but required no significant sacrifice in performance. Using an existing personal computer, the resulting design can be assembled for as little as US$200. The spectrometer performance is demonstrated with spin-echo and Carr–Purcell–Meiboom–Gill pulse sequences on a water sample

  18. A low-cost spectrometer for NMR measurements in the Earth's magnetic field

    Science.gov (United States)

    Michal, Carl A.

    2010-10-01

    We describe and demonstrate an inexpensive, easy-to-build, portable spectrometer for nuclear magnetic resonance measurements in the Earth's magnetic field. The spectrometer is based upon a widely available inexpensive microcontroller, which acts as a pulse programmer, audio-frequency synthesizer and digitizer, replacing what are typically the most expensive specialized components of the system. The microcontroller provides the capability to execute arbitrarily long and complicated sequences of phase-coherent, phase-modulated excitation pulses and acquire data sets of unlimited duration. Suitably packaged, the spectrometer is amenable to measurements in the research lab, in the field or in the teaching lab. The choice of components was heavily weighted by cost and availability, but required no significant sacrifice in performance. Using an existing personal computer, the resulting design can be assembled for as little as US200. The spectrometer performance is demonstrated with spin-echo and Carr-Purcell-Meiboom-Gill pulse sequences on a water sample.

  19. EPC projects for EPR Flamanville 3 NPP

    International Nuclear Information System (INIS)

    Diaz, J.I.; Polo, J.; Aymerich, E.; Cubian, B.

    2010-01-01

    IBERDROLA Ingenieria y Construccion is carrying out a handful of activities in the EPR Flamanville 3 -FA3 NPP- context since 2007 matching oriented to position the company in the emerging marketplace of new nuclear power plants Generation III+, whose expectation for the next years is highly promising. IBERDROLA Ingenieria y Construccion leads 5 EPC -Engineering, Procurement and Commissioning- projects for FA3 NPP from the Nuclear Island till Sea Water Pumping Station as follows: - Design, procurement. fabrication, installation and testing of 21 shell and tubes heat-exchangers for the nuclear island. 12 out of these 17 HXs are conventional and will be designed according to ASME BPV code Section VIII and have to comply with PED 97/23/CE and ESPN. The remaining 5 HXs are nuclear and will be designed according to ASME BPV code Section III and have also to comply with PED and ESPN. - Design, procurement, fabrication and assembly of 9 demineralizers for different plant systems. Three of these Important To Safety (IPS) equipments have been manufactured according with ASME VIII codes and six of them with EN 13445 code plus additional requirements to comply with PED and final client requirements for nuclear island. - Design, fabrication and installation of qualified travelling water screening filters. The equipments furnished will be two nuclear safety qualified filters and associated equipment (cleaning water system and control system). Additionally some auxiliary devices such as grids, automatic trash rakes and stop gates are included in the contract. - Engineering, procurement, fabrication, erection and commissioning for the condensate treatment plant. This system includes a demineralizer tank, 5 filters, reactive injection mixer, pneumatic and manual valves, piping and instrumentation and control systems. - Engineering, procurement erection and commissioning for the electro-chlorination plant to protect the IPS piping for Condensate Water System for FA3. This system

  20. EPC projects for EPR Flamanville 3 NPP

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, J.I.; Polo, J.; Aymerich, E.; Cubian, B. [Nuclear Generation Department, Iberdrola Ingenieria y Construccion, Avda. Manoteras 20, 28050 Madrid (Spain)

    2010-07-01

    IBERDROLA Ingenieria y Construccion is carrying out a handful of activities in the EPR Flamanville 3 -FA3 NPP- context since 2007 matching oriented to position the company in the emerging marketplace of new nuclear power plants Generation III+, whose expectation for the next years is highly promising. IBERDROLA Ingenieria y Construccion leads 5 EPC -Engineering, Procurement and Commissioning- projects for FA3 NPP from the Nuclear Island till Sea Water Pumping Station as follows: - Design, procurement. fabrication, installation and testing of 21 shell and tubes heat-exchangers for the nuclear island. 12 out of these 17 HXs are conventional and will be designed according to ASME BPV code Section VIII and have to comply with PED 97/23/CE and ESPN. The remaining 5 HXs are nuclear and will be designed according to ASME BPV code Section III and have also to comply with PED and ESPN. - Design, procurement, fabrication and assembly of 9 demineralizers for different plant systems. Three of these Important To Safety (IPS) equipments have been manufactured according with ASME VIII codes and six of them with EN 13445 code plus additional requirements to comply with PED and final client requirements for nuclear island. - Design, fabrication and installation of qualified travelling water screening filters. The equipments furnished will be two nuclear safety qualified filters and associated equipment (cleaning water system and control system). Additionally some auxiliary devices such as grids, automatic trash rakes and stop gates are included in the contract. - Engineering, procurement, fabrication, erection and commissioning for the condensate treatment plant. This system includes a demineralizer tank, 5 filters, reactive injection mixer, pneumatic and manual valves, piping and instrumentation and control systems. - Engineering, procurement erection and commissioning for the electro-chlorination plant to protect the IPS piping for Condensate Water System for FA3. This system

  1. Effect of analytical proton beam irradiation on lead-white pigments, characterized by EPR spectroscopy

    Science.gov (United States)

    Gourier, Didier; Binet, Laurent; Gonzalez, Victor; Vezin, Hervé; Touati, Nadia; Calligaro, Thomas

    2018-01-01

    Analytical techniques using proton beams with energy in the MeV range are commonly used to study archeological artefact and artistic objects. However ion beams can induce alteration of fragile materials, which is notably the case of easel paintings, limiting the use of these techniques. We used continuous wave EPR and pulse EPR spectroscopy to reveal the effect of 3 MeV proton irradiation on lead carbonates, which were extensively employed as white pigments from the antiquity to the 20th century. Two kinds of paramagnetic centers were identified in cerussite (PbCO3): the first one is CO3- radicals formed by hole trapping by CO32- ions, and the second one is NO32- radical resulting from electron trapping by NO3- impurities. Hydrocerussite (2PbCO3·Pb(OH)2) is the most darkened material under proton beam, however it exhibits no NO32- radicals and 20 times less CO3- radicals than cerussite. Consequently these paramagnetic centers are not directly responsible for the darkening of lead-white pigments. We proposed that their higher instability in hydrocerussite might be at the origin of the formation of color centers in this material.

  2. Triple axis spectrometers

    International Nuclear Information System (INIS)

    Clausen, K.N.

    1997-01-01

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  3. Linear pulse amplifier

    International Nuclear Information System (INIS)

    Tjutju, R.L.

    1977-01-01

    Pulse amplifier is standard significant part of spectrometer. Apart from other type of amplification, it's a combination of amplification and pulse shaping. Because of its special purpose the device should fulfill the following : High resolution is desired to gain a high yield comparable to its actual state of condition. High signal to noise is desired to nhν resolution. High linearity to facilitate calibration. A good overload recovery, in order to the device will capable of analizing a low energy radiation which appear joinly on the high energy fields. Other expections of the device are its economical and practical use its extentive application. For that reason it's built on a standard NIM principle. Taking also into account the above mentioned considerations. High quality component parts are used throughout, while its availability in the domestic market is secured. (author)

  4. A superconducting electron spectrometer

    International Nuclear Information System (INIS)

    Guttormsen, M.; Huebel, H.; Grumbkow, A. von

    1983-03-01

    The set-up and tests of an electron spectrometer for in-beam conversion electron measurements are described. A superconducting solenoid is used to transport the electrons from the target to cooled Si(Li) detectors. The solenoid is designed to produce either a homogeneous axially symmetric field of up to 2 Tesla or a variety of field profiles by powering the inner and outer set of coils of the solenoid separately. The electron trajectories resulting for various field profiles are discussed. In-beam electron spectra taken in coincidence with electrons, gammas and alpha-particles are shown. (Auth.)

  5. Intermediate PT jet spectrometers

    International Nuclear Information System (INIS)

    Gutay, L.J.; Koltick, D.; Hauptman, J.; Stork, D.; Theodosiou, G.

    1988-01-01

    A design is presented for a limited solid angle, high resolution double arm spectrometer at 90 degree to the begin, with a vertex detector and particle identification in both arms. The jet arm is designed to accept a complete jet, and identify its substructure of sub-jets, hadrons, and leptons. The particle arm would measure e,π,K,p ratios for P T 0 to the beam for the purpose of tagging Higgs production by boson fusion, 1 gauge boson (WW, ZZ, and WZ) scattering 2 L, and other processes involving the interactions of virtual gauge bosons

  6. HISS spectrometer at LBL

    International Nuclear Information System (INIS)

    Greiner, D.

    1980-11-01

    The Heavy Ion Spectrometer System at LBL is designed to be a general purpose experimental work bench able to support a wide variety of experiments. Our philosophy is to provide instruments capable of investigating, with multi-particle sensitivity, a large portion of phase space. We have not chosen a particular region such as mid-rapidity or projectile frame but, instead, have made sure that the magnet and the instrumentation allow these choices as well as many others. The beam can be brought into the magnet at a variable position and the magnet can be rotated

  7. Gas Chromatic Mass Spectrometer

    Science.gov (United States)

    Wey, Chowen

    1995-01-01

    Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

  8. Olkiluoto 3: Finland has chosen a EPR

    International Nuclear Information System (INIS)

    Brummer, S.

    2003-01-01

    According to the Finn law any nuclear project has to be declared conformed to the general interest of the country by the government and then has to be approved by the parliament. In may 2002 the Finn parliament approved the project of the TVO company: the construction of a new nuclear unit on the Olkiluoto site and the direct and definitive disposal of spent fuels in the granite underground layers of the same site. The project was agreed with 109 votes for and 92 against. In september 2002 an international invitation to tender was launched and 4 companies made proposals: Westinghouse, Atomstroexport, Framatome-ANP and General Electric. Westinghouse withdrew its offer some time later. In october 2003 TVO announced that the unit will be a 1600 MW EPR (European pressurized reactor) built by Framatome-ANP. The construction work will begin in spring 2005 and the unit is scheduled to enter into service in 2009. At that time the contribution of nuclear energy to the Finn energy production will reach 35%. (A.C.)

  9. EPR by Areva. The path of greatest certainty

    International Nuclear Information System (INIS)

    2008-01-01

    AREVA's Evolutionary Power Reactor (EPR) is the first Generation III+ reactor design currently being built to answer the world's growing demand for clean and reliable electricity generation. Already under construction in Finland, France and China, the EPR is also being considered by America, United Kingdom, South Africa and other countries for the development of their nuclear fleet. The EPR is now clearly destined to become the mainstay of standardized, efficient reactor fleets around the globe. AREVA's EPR incorporates unbeatable know-how provided by an uninterrupted track record of reactor building activities and backed by decades of feedback experience from operating PWRs, including the most recent. The EPR is a Franco-German initiative which benefited from the stringent scrutiny of safety authorities from both countries, at each stage of the project. The EPR has already secured construction licenses from two of the world's most demanding safety authorities in France and Finland and is currently in line for a design certification and a combined construction and operating license (COL) in the USA. It is also taking part in the licensing process recently launched in the United Kingdom. Europe's leading utilities have granted the EPR their approval under the 'European Utilities Requirements' and have further expressed individual interest in the design and performance of the EPR for their businesses. AREVA is the only Gen III+ reactor constructor in the world with ongoing building experience. To date, AREVA is the only vendor who has the necessary field experience that future customers can benefit: - Detailed design completed; - Experience feedback from 87 PWR; - 3 projects going on; - Continuous PWR experience in design and construction. Close to 100% of the EPR primary circuit heavy components are sourced directly from AREVA's integrated plants. Engineering, manufacturing, services and fuel cycle management are totally integrated and mastered by AREVA. From its

  10. EPR by Areva. The path of greatest certainty

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    AREVA's Evolutionary Power Reactor (EPR) is the first Generation III+ reactor design currently being built to answer the world's growing demand for clean and reliable electricity generation. Already under construction in Finland, France and China, the EPR is also being considered by America, United Kingdom, South Africa and other countries for the development of their nuclear fleet. The EPR is now clearly destined to become the mainstay of standardized, efficient reactor fleets around the globe. AREVA's EPR incorporates unbeatable know-how provided by an uninterrupted track record of reactor building activities and backed by decades of feedback experience from operating PWRs, including the most recent. The EPR is a Franco-German initiative which benefited from the stringent scrutiny of safety authorities from both countries, at each stage of the project. The EPR has already secured construction licenses from two of the world's most demanding safety authorities in France and Finland and is currently in line for a design certification and a combined construction and operating license (COL) in the USA. It is also taking part in the licensing process recently launched in the United Kingdom. Europe's leading utilities have granted the EPR their approval under the 'European Utilities Requirements' and have further expressed individual interest in the design and performance of the EPR for their businesses. AREVA is the only Gen III+ reactor constructor in the world with ongoing building experience. To date, AREVA is the only vendor who has the necessary field experience that future customers can benefit: - Detailed design completed; - Experience feedback from 87 PWR; - 3 projects going on; - Continuous PWR experience in design and construction. Close to 100% of the EPR primary circuit heavy components are sourced directly from AREVA's integrated plants. Engineering, manufacturing, services and fuel cycle management are totally

  11. The effect of thermal treatment on radiation-induced EPR signals in tooth enamel

    International Nuclear Information System (INIS)

    Vorona, I.P.; Ishchenko, S.S.; Baran, N.P.

    2005-01-01

    The effect of thermal treatment on the radiation-induced EPR spectrum of tooth enamel was studied. Annealing before sample irradiation was found to increase enamel radiation sensitivity by more than 40%. Depending on the annealing conditions the EPR signals of three supplementary radiation radicals were observed in addition to the main signal caused by CO 2 - radicals. It was found that the presence of these signals in the enamel EPR spectra provides evidence of sample annealing. The possibility of obtaining information about sample history by studying the additional EPR signals is discussed. It can be important to EPR dating and EPR dosimetry

  12. Energy-dependent losses in pulsed-feedback preamplifiers

    International Nuclear Information System (INIS)

    Landis, D.A.; Madden, N.W.; Goulding, F.S.

    1978-11-01

    Energy dependent counting losses occur in most pulsed-feedback preamplifiers due to the loss of those pulses which activate the recharge system. A pulsed-feedback system that overcomes this inefficiency is described. Pulsed-light feedback as used with germanium gamma-ray spectrometers is discussed as used at high energies and high rates where those losses become significant. Experimental results are presented

  13. The measurement of oxygen in vivo using EPR techniques

    International Nuclear Information System (INIS)

    Swartz, Harold M.; Clarkson, Robert B.

    1998-01-01

    The measurement of pO 2 in vivo using EPR has some features which have already led to very useful applications and this approach is likely to have increasingly wide and effective use. It is based on the effect of oxygen on EPR spectra which provides a sensitive and accurate means to measure pO 2 quantitatively. The development of oxygen-sensitive paramagnetic materials which are very stable, combined with instrumental developments, has been crucial to the in vivo applications of this technique. The physical basis and biological applications of in vivo EPR oximetry are reviewed, with particular emphasis on the use of EPR spectroscopy at 1 GHz using particulate paramagnetic materials for the repetitive and non-invasive measurement of pO 2 in tissues. In vivo EPR has already produced some very useful results which have contributed significantly to solving important biological problems. The characteristics of EPR oximetry which appear to be especially useful are often complementary to existing techniques for measuring oxygen in tissues. These characteristics include the capability of making repeated measurements from the same site, high sensitivity to low levels of oxygen, and non-invasive options. The existing techniques are especially useful for studies in small animals, where the depth of measurements is not an overriding issue. In larger animals and potentially in human subjects, non-invasive techniques seem to be immediately applicable to study phenomena very near the surface (within 10 mm) while invasive techniques have some very promising uses. The clinical uses of EPR oximetry which seem especially promising and likely to be undertaken in the near future are long-term monitoring of the status and response to treatment of peripheral vascular disease and optimizing cancer therapy by enabling it to be modified on the basis of the pO 2 measured in the tumour. (author)

  14. Perspectives and possibilities for solid state physcis investigations at thhe pulsed reactor IBR-2 of the JINR Dubna

    International Nuclear Information System (INIS)

    Feldmann, K.; Frauenheim, T.; Lauckner, J.; Weniger, J.; Muehle, E.

    1982-02-01

    Three time-of-flight spectrometers (spectrometer of high resolution NSWR, spectrometer of inverted geometry KDSOG and spectrometer of polarized neutrons SPN-1) are presented, which will be working at the pulsed IBR-2 reactor of the JINR Dubna. Considering the parameters and the special methods of measurement of these spectrometers, the possibilities of their applications for the investigations of structural, magnetic and electronic properties of solids by means of elastic, inelastic and quasielastic neutron scattering are discussed. (author)

  15. Software for analysis of waveforms acquired by digital Doppler broadening spectrometer

    International Nuclear Information System (INIS)

    Vlcek, M; Čížek, J; Procházka, I

    2013-01-01

    High-resolution digital spectrometer for coincidence measurement of Doppler broadening of positron annihilation radiation was recently developed and tested. In this spectrometer pulses from high purity Ge (HPGe) detectors are sampled in the real time by fast digitizers and subsequently analyzed off-line by software. We present description of the software routines used for pulse shape analysis in two spectrometer configurations: (i) semi-digital setup in which detector pulses shaped in spectroscopic amplifiers (SA's) are digitized; (ii) pure digital setup in which pulses from detector pre-amplifiers are digitized directly. Software developed in this work will be freely available in the form of source code and pre-compiled binaries.

  16. Resonant ultrasound spectrometer

    Science.gov (United States)

    Migliori, Albert; Visscher, William M.; Fisk, Zachary

    1990-01-01

    An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.

  17. Prototype Neutron Energy Spectrometer

    International Nuclear Information System (INIS)

    Mitchell, Stephen; Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald

    2010-01-01

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production (ship effect), (a, n) reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  18. Prototype Neutron Energy Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Mitchell, Sanjoy Mukhopadhyay, Richard Maurer, Ronald Wolff

    2010-06-16

    The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

  19. The SPEDE electron spectrometer

    CERN Document Server

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  20. Simulation of the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Cox, D.M.; Herzberg, R.D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Hauschild, K. [Universite Paris-Sud, CSNSM-IN2P3-CNRS, Orsay (France)

    2015-06-15

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  1. Simulation of the SAGE spectrometer

    International Nuclear Information System (INIS)

    Cox, D.M.; Herzberg, R.D.; Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J.; Hauschild, K.

    2015-01-01

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  2. LADEE Neutral Mass Spectrometer Data

    Data.gov (United States)

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  3. Meeting the next generation PWR safety requirements: The EPR Reactor

    International Nuclear Information System (INIS)

    Salhi, Othman

    2008-01-01

    The development process pursued the harmonization of technical solutions and the integration of all the lessons learned from earlier nuclear plants built by both vendors. As far as safety more specifically is concerned, the basic choice for the EPR was to adopt an evolutionary approach based on experience feedback from the reactors built by Areva, which at the time already amounted to nearly 100. This philosophy makes today's Areva EPR the natural descendant of the most advanced French N4 and German Konvoi power reactors currently in operation. EPR design choices affecting safety were motivated by a continuous quest for higher levels of safety. A two-fold approach was followed: 1. improvement of the measures aimed at further reducing the already very low probability of core melt 2. incorporation of measures aimed at further limiting the consequences of a severe accident, in the knowledge that its probability of occurrence has been considerably reduced. Through its filiations with French N4 and German Konvoi power reactors, the EPR benefits from the uninterrupted, evolutionary innovation process that has supported the development of PWRs since their introduction into the market place. This is especially true for safety where the EPR brings a unique combination of both tried and tested and innovative features that further improve the prevention of severe accidents and their mitigation

  4. Applications of EPR steering in quantum teleportation and NOON states

    Science.gov (United States)

    Zárate, Laura Rosales

    2018-04-01

    Einstein-Podolsky-Rosen (EPR) steering refers to the type of correlations described in the EPR paradox, where one observer seems to affect ("steer") the state of other observer by using local measurements. There have been several works regarding characterization and quantification of EPR steering. One characteristic of this non-local correlation is that it can be asymmetric, while entanglement is symmetric. This asymmetric property is relevant for potential applications of EPR steering to quantum information, in particular to quantum cryptography and quantum teleportation. This latter refers to the process where one observer sends an unknown quantum state to Bob, who is in a different location. They communicate by classical means. Here we will show that EPR steering is a necessary resource to obtain secure continuous variable teleportation. We will also consider NOON states, which is an example of an entangled state. For this state, we will present a steering signature. This contribution reviews the work derived in Refs. [1] and [2], which was presented as an invited talk in ELAF 2017.

  5. The use of deciduous molars in EPR dose reconstruction

    International Nuclear Information System (INIS)

    El-faramawy, N.A.; Wieser, A.

    2005-01-01

    The use of deciduous teeth in EPR dose reconstruction has the unique potential to measure individual doses that were accumulated in the early childhood in the age up to 12 years. It was found previously that due to the small size of deciduous incisors, the available amount of enamel is not sufficient for EPR measurements. Therefore, dose assessment with deciduous incisors can only be done by measurement of whole teeth, including enamel and dentine. The measurement of whole teeth instead of enamel alone is possibly less reliable for dose reconstruction because the stability of CO 2 - radicals (that are an indicator for the absorbed dose) in biologically active dentine is not known. In the present study naturally loosed deciduous molars were investigated. The feasibility of separating enamel from small size molars was analysed. EPR spectrum parameters of whole molars and separated enamel only were evaluated before and after laboratory irradiation. The EPR signal amplitudes of the CO 2 - and native signals were determined by spectrum deconvolution, in dependence on radiation dose in the range 0.1 - 10 Gy. The fading at room temperature of native and CO 2 - EPR signals was analysed. The detection threshold for absorbed dose in enamel was determined.

  6. Monitoring sequential electron transfer with EPR

    International Nuclear Information System (INIS)

    Thurnauer, M.C.; Feezel, L.L.; Snyder, S.W.; Tang, J.; Norris, J.R.; Morris, A.L.; Rustandi, R.R.

    1989-01-01

    A completely general model which treats electron spin polarization (ESP) found in a system in which radical pairs with different magnetic interactions are formed sequentially has been described. This treatment has been applied specifically to the ESP found in the bacterial reaction center. Test cases show clearly how parameters such as structure, lifetime, and magnetic interactions within the successive radical pairs affect the ESP, and demonstrate that previous treatments of this problem have been incomplete. The photosynthetic bacterial reaction center protein is an ideal system for testing the general model of ESP. The radical pair which exhibits ESP, P 870 + Q - (P 870 + is the oxidized, primary electron donor, a bacteriochlorophyll special pair and Q - is the reduced, primary quinone acceptor) is formed via sequential electron transport through the intermediary radical pair P 870 + I - (I - is the reduced, intermediary electron acceptor, a bacteriopheophytin). In addition, it is possible to experimentally vary most of the important parameters, such as the lifetime of the intermediary radical pair and the magnetic interactions in each pair. It has been shown how selective isotopic substitution ( 1 H or 2 H) on P 870 , I and Q affects the ESP of the EPR spectrum of P 870 + Q - , observed at two different microwave frequencies, in Fe 2+ -depleted bacterial reaction centers of Rhodobacter sphaeroides R26. Thus, the relative magnitudes of the magnetic properties (nuclear hyperfine and g-factor differences) which influence ESP development were varied. The results support the general model of ESP in that they suggest that the P 870 + Q - radical pair interactions are the dominant source of ESP production in 2 H bacterial reaction centers

  7. BNL multiparticle spectrometer software

    International Nuclear Information System (INIS)

    Saulys, A.C.

    1984-01-01

    This paper discusses some solutions to problems common to the design, management and maintenance of a large high energy physics spectrometer software system. The experience of dealing with a large, complex program and the necessity of having the program controlled by various people at different levels of computer experience has led us to design a program control structure of mnemonic and self-explanatory nature. The use of this control language in both on-line and off-line operation of the program will be discussed. The solution of structuring a large program for modularity so that substantial changes to the program can be made easily for a wide variety of high energy physics experiments is discussed. Specialized tools for this type of large program management are also discussed

  8. A Moessbauer effect spectrometer

    International Nuclear Information System (INIS)

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  9. The Philippine spectrometer

    International Nuclear Information System (INIS)

    Juliano, J.O.

    1965-01-01

    A notable project for international collaboration, in which participants from Indonesia, Korea, Thailand, China and the Philippines are working together, has been launched in the Philippines with Indian assistance under the aegis of the Agency. This is a regional training and research programme using a neutron crystal spectrometer, which has been established since January 1965 at the Philippine Atomic Research Centre in Diliman, Quezon City, Philippines. It is called the IPA Project after the signatories to a five year trilateral agreement, namely, the Government of India,the Republic of the Philippines, and the International Atomic Energy Agency. The programme is administered by a Joint Committee composed of one representative each of the Philippines, India and the Agency. The objective of this cooperative venture is to establish a research centre on neutron diffraction in which scientists and technicians from any Member State of IAEA in South Asia, South-East Asia and Pacific, or Far East regions could come to participate in research and training. Studies in solid state physics, such a s the structure determination of alloys and organic crystals, studies on the orientation of magnetic moments in the lattice of magnetic substances, and other problems based on elastic and inelastic scattering of neutrons are undertaken. There are a number of research reactors in this region where neutron spectrometers can be utilized and the recent establishment of this cooperative international research and training programme has been a timely one for this area of the world. Indeed, a number of other countries have shown a strong growing interest in the development of the project

  10. Pocket PC-based portable gamma-ray spectrometer

    Directory of Open Access Journals (Sweden)

    Kamontip Ploykrachang

    2011-04-01

    Full Text Available A portable gamma-ray spectrometer based on a Pocket PC has been developed. A 12-bit pipeline analog-to-digitalconverter (ADC associated with an implemented pulse height histogram function on field programmable gate array (FPGAoperating at 15 MHz is employed for pulse height analysis from built-in pulse amplifier. The system, which interfaces withthe Pocket PC via an enhanced RS-232 serial port under the microcontroller facilitation, is utilized for spectrum acquisition,display and analysis. The pulse height analysis capability of the system was tested and it was found that the ADC integralnonlinearity of ±0.45% was obtained with the throughput rate at 160 kcps. The overall system performance was tested usinga PIN photodiode-CsI(Tl crystal coupled scintillation detector and gamma standard radioactive sources of Cs-137 andCo-60. Low cost and the compact system size as a result of the implemented logical function are also discussed.

  11. A Local Realistic Reconciliation of the EPR Paradox

    Science.gov (United States)

    Sanctuary, Bryan

    2014-03-01

    The exact violation of Bell's Inequalities is obtained with a local realistic model for spin. The model treats one particle that comprises a quantum ensemble and simulates the EPR data one coincidence at a time as a product state. Such a spin is represented by operators σx , iσy ,σz in its body frame rather than the usual set of σX ,σY ,σZ in the laboratory frame. This model, assumed valid in the absence of a measuring probe, contains both quantum polarizations and coherences. Each carries half the EPR correlation, but only half can be measured using coincidence techniques. The model further predicts the filter angles that maximize the spin correlation in EPR experiments.

  12. ER=EPR, GHZ, and the consistency of quantum measurements

    International Nuclear Information System (INIS)

    Susskind, Leonard

    2016-01-01

    This paper illustrates various aspects of the ER=EPR conjecture. It begins with a brief heuristic argument, using the Ryu-Takayanagi correspondence, for why entanglement between black holes implies the existence of Einstein-Rosen bridges. The main part of the paper addresses a fundamental question: Is ER=EPR consistent with the standard postulates of quantum mechanics? Naively it seems to lead to an inconsistency between observations made on entangled systems by different observers. The resolution of the paradox lies in the properties of multiple black holes, entangled in the Greenberger-Horne-Zeilinger pattern. The last part of the paper is about entanglement as a resource for quantum communication. ER=EPR provides a way to visualize protocols like quantum teleportation. In some sense teleportation takes place through the wormhole, but as usual, classical communication is necessary to complete the protocol. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Retrospective dosimetry using EPR and TL techniques: a status report

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1996-01-01

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance

  14. EPR structure of the gamma irradiated alanine spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Cabral P, A; Jimenez D, H; Urena N, F; Galindo, S; Bosch, P

    1992-03-15

    In this study is shown that the broadened five-line EPR pattern of the gamma irradiated alanine possibly decomposes into a more complex pattern when the recorded spectrum is subject to an operation of deconvolution. The EPR powder spectra of gamma irradiated DL- and L-alanine with and without binders are analysed. In all recorded spectra, each observed line is resolved into an asymmetrical triplet when a Gaussian distribution of 8.2 gauss width is removed, by deconvolution, from the observed spectrum. On the other hand, from a simple fitting analysis carried out on the original data, one encounters that some calculated relations between characteristic parameters, such as intensity ratios, deviate consistently from assumed height ratios. Both, from deconvolution and fitting results, a different structure is suggested for the observed broadened five-line EPR pattern of {gamma}-irradiated powder DL- and L-alanine. (Author)

  15. Free radical EPR in delineating oil bearing zones

    International Nuclear Information System (INIS)

    Sharma, R.K.; Kumar, V.; Das, T.K.; Gundu Rao, T.K.

    1993-01-01

    Presence of naturally occurring gamma ray activity has long been detected in oil/gas wells is invariably carried out for formation evaluation. Similarly, presence of free radicals in oil bearing formations has also been known for quite sometime. Present paper deals with a systematic study of detecting these free radicals in oil wells and correlations of these with x-ray and other logs for identification of hydrocarbon bearing zones. Present study attempts to establish EPR as as inexpensive and reliable tool in comparison with gamma ray and neutron density logs recorded in exploratory oil wells. EPR studies have been carried out in an exploratory well between depth intervals 1600 m-1400 m located in south of existing producing field in Bombay Offshore region. Based on these results, an EPR log has been prepared and compared with gamma ray and neutron density logs. (author). 4 refs., 1 fig., 1 tab

  16. Retrospective dosimetry using EPR and TL techniques: a status report

    Energy Technology Data Exchange (ETDEWEB)

    Haskell, E.H.

    1996-12-31

    Methods of retrospective dosimetry, including luminescence and electron paramagnetic resonance spectroscopy (EPR), rely on measurement of accident dose absorbed by naturally occurring materials - ceramics in the case of both thermoluminescence (TL) and optically stimulated luminescence (OSL) and organic materials and bio- minerals in the case of EPR. Each of these methods relies on measurement of radiation defects resulting from accidental exposure. Since defects also result from natural sources of radiation over the lifetime of a sample, analysis is usually restricted to materials for which the natural dose may be determined and subtracted from the measured cumulative dose. Luminescence dating techniques rely heavily on an accurate assessment of cumulative dose from natural radiation sources, and dating research has provided us with the bulk of our knowledge in this area. Virtually all of the work on natural dose determination can be directly applied to retrospective techniques. With EPR techniques the cumulative dose from diagnostic x- rays is also of importance.

  17. EPR and TL correlation in some powdered Greek white marbles

    International Nuclear Information System (INIS)

    Baieetto, Vanessa; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-01-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perp =2.0038 and g par =2.0024 due to the SO - 3 centre and the B one with g 1 =2.0005; g 2 =2.0001; g 3 =1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO - 3 centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal

  18. EPR and TL correlation in some powdered Greek white marbles

    Energy Technology Data Exchange (ETDEWEB)

    Baieetto, Vanessa E-mail: crpaa@montaigne.u-bordeaux.fr; Villeneuve, Gerard; Guibert, Pierre; Schvoerer, Max

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 deg. C and 360 deg. C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g{sub perp}=2.0038 and g{sub par} =2.0024 due to the SO{sup -}{sub 3} centre and the B one with g{sub 1}=2.0005; g{sub 2}=2.0001; g{sub 3}=1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 deg. C TL peak is associated to the A signal and thus to the SO{sup -}{sub 3} centre and the 360 deg. C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  19. EPR and TL correlation in some powdered Greek white marbles.

    Science.gov (United States)

    Baïetto, V; Villeneuve, G; Guibert, P; Schvoerer, M

    2000-02-01

    Thermoluminescence of white powdered marble samples, chosen to display different EPR spectra, were studied. Two peaks at 280 degrees C and 360 degrees C can be observed among the TL glow curves while the EPR spectra exhibit two signals: the A signal with g perpendicular = 2.0038 and g parallel = 2.0024 due to the SO3- centre and the B one with g1 = 2.0005; g2 = 2.0001; g3 = 1.9998 due to mechanical powder reduction (drilling). Owing to heating and simultaneous experiments, a correlation have been established: the 280 degrees C TL peak is associated to the A signal and thus to the SO3- centre and the 360 degrees C TL peak is caused by mechanical treatment corresponding to the B EPR signal.

  20. EPR structure of the gamma irradiated alanine spectrum

    International Nuclear Information System (INIS)

    Cabral P, A.; Jimenez D, H.; Urena N, F.; Galindo, S.; Bosch, P.

    1992-03-01

    In this study is shown that the broadened five-line EPR pattern of the gamma irradiated alanine possibly decomposes into a more complex pattern when the recorded spectrum is subject to an operation of deconvolution. The EPR powder spectra of gamma irradiated DL- and L-alanine with and without binders are analysed. In all recorded spectra, each observed line is resolved into an asymmetrical triplet when a Gaussian distribution of 8.2 gauss width is removed, by deconvolution, from the observed spectrum. On the other hand, from a simple fitting analysis carried out on the original data, one encounters that some calculated relations between characteristic parameters, such as intensity ratios, deviate consistently from assumed height ratios. Both, from deconvolution and fitting results, a different structure is suggested for the observed broadened five-line EPR pattern of γ-irradiated powder DL- and L-alanine. (Author)

  1. A High Sensitivity EPR Technique for Alanine Dosimetry (invited paper)

    International Nuclear Information System (INIS)

    Haskell, E.H.; Hayes, R.B.; Kenner, G.H.

    1998-01-01

    Uncertainties of ± 5 mGy were achieved in the measurement of alanine dosemeters using optimised EPR parameters, instrumentation, spectral manipulation and subtraction techniques. Modulation amplitude and microwave power were adjusted to combine resonances of two neighbouring alanine signals. Instrumental variations were minimised by combining and subtracting pre- and post-measurement spectra of the empty EPR tube. A spectrum of the native signal of non-dosed alanine was generated from a single batch of dosemeters and subtracted from spectra of the irradiated dosemeters, also from the same batch. Field alignment was adjusted with the use of an in-cavity Mn ++ standard. A constant rotation goniometer was used to eliminate anisotropies in the EPR tube and alanine samples. Finally, digital filters were applied to the resulting spectra. (author)

  2. Study of growth of polyaniline chain by EPR method

    Energy Technology Data Exchange (ETDEWEB)

    Kulikov, A V [Inst. of Chemical Physics, Chernogolovka (Russian Federation); Kogan, Ya L [Inst. of Chemical Physics, Chernogolovka (Russian Federation); Fokeeva, L S [Inst. of Chemical Physics, Chernogolovka (Russian Federation)

    1993-03-22

    Chemical aniline polymerization has been studied by the EPR method. After a long delay a weak EPR signal I is appeared and transformed rapidly into a strong Lorentzian line. Constants of spin exchange of signals I and II with paramagnetic probes Fe(CN)[sub 6][sup 3-], Co[sup 2+] and O[sub 2], freely diffusing in solution, have been determined. Effect of ferricyanide ions and urea, a breaker of hydrogen bonds, has been measured for signals I and II. Data obtained show the formation of an array of positive charges in PANI at early stage of doping. Constants of spin exchange depend on prehistory of samples. Averaging of EPR line widths of different paramagnetic centers in polyaniline was found. (orig.)

  3. ER=EPR, GHZ, and the consistency of quantum measurements

    Energy Technology Data Exchange (ETDEWEB)

    Susskind, Leonard [Stanford Institute for Theoretical Physics and Department of Physics, Stanford University, Stanford, CA (United States)

    2016-01-15

    This paper illustrates various aspects of the ER=EPR conjecture. It begins with a brief heuristic argument, using the Ryu-Takayanagi correspondence, for why entanglement between black holes implies the existence of Einstein-Rosen bridges. The main part of the paper addresses a fundamental question: Is ER=EPR consistent with the standard postulates of quantum mechanics? Naively it seems to lead to an inconsistency between observations made on entangled systems by different observers. The resolution of the paradox lies in the properties of multiple black holes, entangled in the Greenberger-Horne-Zeilinger pattern. The last part of the paper is about entanglement as a resource for quantum communication. ER=EPR provides a way to visualize protocols like quantum teleportation. In some sense teleportation takes place through the wormhole, but as usual, classical communication is necessary to complete the protocol. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. The laser-based calibration system of delta spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Malakhov, A.I. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Anisimov, Yu.S. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Gmuca, S. [Inst. of Physics, SAS, Bratislava (Slovakia); Kizka, V.A. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Kliman, J. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Inst. of Physics, SAS, Bratislava (Slovakia); Krasnov, V.A. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Kurepin, A.B. [Inst. for Nuclear Research RAS, Moscow (Russian Federation); Kuznetsov, S.N. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Livanov, A.N. [Veksler and Baldin Laboratory of High Energies, JINR, Dubna (Russian Federation); Matousek, V. [Inst. of Physics, SAS, Bratislava (Slovakia); Morhac, M. [Inst. of Physics, SAS, Bratislava (Slovakia)]. E-mail: Miroslav.Morhac@savba.sk; Turzo, I. [Inst. of Physics, SAS, Bratislava (Slovakia)

    2006-10-15

    We present a report on a laser calibration system of DELTA spectrometer that has been designed and developed in the Laboratory of High Energies, JINR, Dubna. The system is intended for monitoring and continuous stabilization of the outputs of the detectors of the spectrometer. The UV nitrogen pulse laser along with optical filters, collection of optical fibers and plastic scintillators serving for conversion of UV light pulses to longer wavelength and for diffusion of the light beam to illuminate 300 photomultipliers are used. We stabilize the positions of laser peaks by corrections of high voltages of the corresponding photomultipliers. The proposed system allows one to accomplish the stabilization during the experiment with the use of the same electronics. The control software together with the first results from test runs are described as well.

  5. Orientation-dependent effects of EPR-measurements on β-rhombohedral boron

    International Nuclear Information System (INIS)

    Siems, C.D.; Geist, D.

    1976-01-01

    EPR studies on β-rhombohedral boron have been reported by several authors. Two EPR-lines with the same g-value have been found by measurements with and without illumination. The microwave frequency used was 9 GHz, as far as is known. In this paper EPR-measurements at 35 GHz on β-rhombohedral boron single crystals are reported. The investigations concerning the 'dark EPR-line' were made at 300 K. (Auth.)

  6. MEMS based digital transform spectrometers

    Science.gov (United States)

    Geller, Yariv; Ramani, Mouli

    2005-09-01

    Earlier this year, a new breed of Spectrometers based on Micro-Electro-Mechanical-System (MEMS) engines has been introduced to the commercial market. The use of these engines combined with transform mathematics, produces powerful spectrometers at unprecedented low cost in various spectral regions.

  7. A spectrometer filter for semiconductor and scintillation detectors

    International Nuclear Information System (INIS)

    Andronov, O.I.; Brovchenko, V.G.; Evdokimov, S.T.

    1995-01-01

    The paper describes an integrating low-pass filter which takes signals from a delay line. The filter changes triangular pulses into rectangular ones. The energy resolution of a semiconductor detector whose signal is processed by the filter is 15-20% better than using a common RC-filter. The integrator stores a charge due to the scintillation pulse during the integration time without loss. The energy and time resolution of the device with the spectrometer filter is better than with an RC-filter. The energy resolution of a bismuth-germanate detector in recording radiation from 137 Cs is 9.75%

  8. The EPR - technology for the 3rd millennium

    International Nuclear Information System (INIS)

    Bernstrauch, O.; Dubois, F.

    2001-01-01

    This paper is a story of a successful Franco-German co-operation: the EPR project. It is a rundown of the history of the EPR, before a decision is made to launch the lead-unit construction. The EPR is expected to progressively replace the existing nuclear power plants when they will reach the end of their service life. It integrates the latest technological advances, especially in safety and operational aspects and comprises more than 30 years operating experience. Thus, the EPR combines the qualities of its predecessors, the French N4 and the German Konvoi. The safety of the EPR was maximized both to prevent hypothetical accidents - even severe ones - and to reduce their consequences (corium spreading area, pre-stressed double containment with local liner, four-train safety systems...). The n+2 strategy (in the event of a problem with one train and even if a second train is undergoing maintenance, the remaining two are sufficient to perform the function) allows to perform maintenance during operation which leads consequently to short outage periods, highest availabilities and economical operation. Moreover, most of the EPR components are the result of mastered evolution. The reactor vessel, as a key element for the reactor service life, is designed to be in service for 60 years, the core is large (241 fuel elements instead of 205 in the N4 or 193 in the Konvoi) and the steam generators have higher efficiency. Along the same line, the core and core barrel design have been modified to allow a reduced uranium enrichment and the increase to 65 Gigawatt-day per metric-ton of the fuel discharge burn-up. Finally, the instrumentation and control systems minimize human error by giving the operators a grace period of at least 30 minutes to make decisions. (authors)

  9. Free-radical probes for functional in vivo EPR imaging

    Science.gov (United States)

    Subramanian, S.; Krishna, M. C.

    2007-02-01

    Electron paramagnetic resonance imaging (EPRI) is one of the recent functional imaging modalities that can provide valuable in vivo physiological information on its own merit and aids as a complimentary imaging technique to MRI and PET of tissues especially with respect to in vivo pO II (oxygen partial pressure), redox status and pharmacology. EPR imaging mainly deals with the measurement of distribution and in vivo dynamics and redox changes using special nontoxic paramagnetic spin probes that can be infused into the object of investigation. These spin probes should be characterized by simple EPR spectra, preferably with narrow EPR lines. The line width should be reversibly sensitive to the concentration of in vivo pO II with a linear dependence. Several non-toxic paramagnetic probes, some particulate and insoluble and others water-soluble and infusible (by intravenous or intramuscular injection) have been developed which can be effectively used to quantitatively assess tissue redox status, and tumor hypoxia. Quantitative assessment of the redox status of tissue in vivo is important in investigating oxidative stress, and that of tissue pO II is very important in radiation oncology. Other areas in which EPR imaging and oxymetry may help are in the investigation of tumorangiogenesis, wound healing, oxygenation of tumor tissue by the ingestion of oxygen-rich gases, etc. The correct choice of the spin probe will depend on the modality of measurement (whether by CW or time-domain EPR imaging) and the particular physiology interrogated. Examples of the available spin probes and some EPR imaging applications employing them are presented.

  10. NQR spectrometer controlled by a computer

    International Nuclear Information System (INIS)

    Stoican, Ovidiu

    2002-01-01

    Nuclear quadrupole resonance (NQR) is one of the sensitive methods for studying physical and chemical properties of a substance, such as chemical composition, molecular structure, molecular motion and electronic environment. The specifications of the research project require the use of a nuclear quadrupole resonance spectrometer. Design and performances of a pulsed nuclear quadrupole resonance spectrometer prototype covering the range 1-10 MHz are presented. The pulsed NQR method offers considerably higher sensitivity than either the marginal oscillator or super-regenerative methods. Strong echoes are often observed directly with an oscilloscope or a simple receiver. The method allows us to observe two signal categories: free induction decay (fid) and echoes. The block diagram of the pulsed nuclear quadrupole resonance spectrometer is shown. All operations performed by the spectrometer are controlled by a computer. The scanning frequency range, amplitude and width of the RF pulse, additional magnetic field and sample temperature can be controlled by the software. Also it is possible to improve the signal-to-noise ratio using digital filtering applied to the data stored. Automatic operation eliminates operator skill and uncertainty of manual operation. The NQR spectrometer control software is a stand alone executable file, runs on Windows 95/98 platform and does not require the existence of another software package. A graphical interface allows to user an easy control over the spectrometer operations. All measured parameters by the control system interface are saved in the standard data files and can be processed further. The design is readily adaptable for other applications. The sample is contained within an aluminum cylindrical case. The upper end cap of the case can be removed and it allows introducing the sample. On the upper end cap RF and main temperature sensor connector are placed. On the internal side of the bottom end cap a thermoelectric cooler (MELCOR

  11. On Aerts' overlooked solution to the EPR paradox

    OpenAIRE

    de Bianchi, Massimiliano Sassoli

    2018-01-01

    The Einstein-Podolsky-Rosen (EPR) paradox was enunciated in 1935 and since then it has made a lot of ink flow. Being a subtle result, it has also been largely misunderstood. Indeed, if questioned about its solution, many physicists will still affirm today that the paradox has been solved by the Bell-test experimental results, which have shown that entangled states are real. However, this remains a wrong view, as the validity of the EPR ex-absurdum reasoning is independent from the Bell-test e...

  12. EPR of VHal centres in SrS

    International Nuclear Information System (INIS)

    Seeman, V.; Danilkin, M.; Must, M.; Ots, A.; Paernoja, E.; Pung, L.; Tarkpea, K.

    2006-01-01

    V Hal centres were studied by EPR in SrS doped with halogens after X-raying the samples at 77 K. V Hal centre arises when a hole is captured by sulphide-ion next to a cation vacancy with a halogen ion substituting the opposite sulphide-ion. EPR parameters and thermal decay characteristics are measured for V Cl , V Br , and V I centres. The efficiency of different halogens to produce and stabilise cation vacancies is shown to vary for different alkaline earth sulphides. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. Bell's theorem based on a generalized EPR criterion of reality

    International Nuclear Information System (INIS)

    Eberhard, P.H.; Rosselet, P.

    1995-01-01

    First, the demonstration of Bell's theorem, i.e., of the nonlocal character of quantum theory, is spelled out using the EPR criterion of reality as premises and a gedanken experiment involving two particles. Then, the EPR criterion is extended to include quantities predicted almost with certainty, and Bell's theorem is demonstrated on these new premises. The same experiment is used but in conditions that become possible in real life, without the requirements of ideal efficiencies and zero background. Very high efficiencies and low background are needed, but these requirements may be met in the future

  14. EPR studies of gamma-irradiated taurine single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Bulut, A. E-mail: abulut@samsun.omu.edu.tr; Karabulut, B.; Tapramaz, R.; Koeksal, F

    2000-04-01

    An EPR study of gamma-irradiated taurine [C{sub 2}H{sub 7}NO{sub 3}S] single crystal was carried out at room temperature. The EPR spectra were recorded in the three at mutually perpendicular planes. There are two magnetically distinct sites in monoclinic lattice. The principle values of g and hyperfine constants for both sites were calculated. The results have indicated the presence of {sup 32}SO{sup -}{sub 2} and {sup 33}SO{sup -}{sub 2} radicals. The hyperfine values of {sup 33}SO{sup -}{sub 2} radical were used to obtain O-S-O bond angle for both sites.

  15. EPR of defects in semiconductors: past, present, future

    International Nuclear Information System (INIS)

    Watkins, G.D.

    1999-01-01

    Important physical concepts learned from early EPR studies of defects in silicon are reviewed. Highlighted are the studies of shallow effective-mass-liked donors and acceptors of deep transition element impurities, and of vacancies and interstitials. It is shown that the concepts learned in silicon translate remarkable well to the corresponding defects in the other elemental and compound semiconductors. The introduction of sensitive optical and electrical detection methods and the recent progress in single defects detection insure the continued vital role of EPR in the future

  16. EPR studies of gamma-irradiated taurine single crystals

    International Nuclear Information System (INIS)

    Bulut, A.; Karabulut, B.; Tapramaz, R.; Koeksal, F.

    2000-01-01

    An EPR study of gamma-irradiated taurine [C 2 H 7 NO 3 S] single crystal was carried out at room temperature. The EPR spectra were recorded in the three at mutually perpendicular planes. There are two magnetically distinct sites in monoclinic lattice. The principle values of g and hyperfine constants for both sites were calculated. The results have indicated the presence of 32 SO - 2 and 33 SO - 2 radicals. The hyperfine values of 33 SO - 2 radical were used to obtain O-S-O bond angle for both sites

  17. The inner containment of an EPR trademark pressurized water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ostermann, Dirk; Krumb, Christian; Wienand, Burkhard [AREVA GmbH, Offenbach (Germany)

    2014-08-15

    On February 12, 2014 the containment pressure and subsequent leak tightness tests on the containment of the Finnish Olkiluoto 3 EPR trademark reactor building were completed successfully. The containment of an EPR trademark pressurized water reactor consists of an outer containment to protect the reactor building against external hazards (such as airplane crash) and of an inner containment that is subjected to internal overpressure and high temperature in case of internal accidents. The current paper gives an overview of the containment structure, the design criteria, the validation by analyses and experiments and the containment pressure test.

  18. Bell's theorem based on a generalized EPR criterion of reality

    International Nuclear Information System (INIS)

    Eberhard, P.H.; Rosselet, P.

    1993-04-01

    First, the demonstration of Bell's theorem, i.e. of the non-local character of quantum theory, is spelled out using the EPR criterion of reality as premises and a gedanken experiment involving two particles. Then, the EPR criterion is extended to include quantities predicted almost with certainty, and Bell's theorem is demonstrated on these new premises. The same experiment is used but in conditions that become possible in real life, without the requirements of ideal efficiencies and zero background. Very high efficiencies and low background are needed, but these requirements may be met in the future. (author) 1 fig., 11 refs

  19. Nuclear choice. Towards the EPR with mincing steps

    International Nuclear Information System (INIS)

    Jemain, A.

    2003-01-01

    The French government is on the way to give its green light for the construction of the EPR (European Pressurized water Reactor), the 1600 MWe demonstrator reactor of third generation of Framatome ANP (Areva). Fifty seven months will be necessary for its construction which, with the public inquiry, would lead to a first commissioning by 2010. This reactor will progressively renew the present day park between 2015-2020. The EPR project will cost 3 billions of euros but the financing remains to be found. Short paper. (J.S.)

  20. 75 FR 4882 - Meeting of the ACRS Subcommittee on EPR; Notice of Meeting

    Science.gov (United States)

    2010-01-29

    ... NUCLEAR REGULATORY COMMISSION Advisory Committee On Reactor Safeguards (ACRS) Meeting of the ACRS Subcommittee on EPR; Notice of Meeting The ACRS U.S. Evolutionary Power Reactor (EPR) Subcommittee will hold a... with Open Items concerning the U.S. EPR Design Certification (DCD) Application and the Calvert Cliffs...

  1. High-frequency EPR on high-spin transition-metal sites

    NARCIS (Netherlands)

    Mathies, Guinevere

    2012-01-01

    The electronic structure of transition-metal sites can be probed by electron-paramagnetic-resonance (EPR) spectroscopy. The study of high-spin transition-metal sites benefits from EPR spectroscopy at frequencies higher than the standard 9.5 GHz. However, high-frequency EPR is a developing field. In

  2. VESUVIO--the double difference inverse geometry spectrometer at ISIS

    International Nuclear Information System (INIS)

    Mayers, J.; Tomkinson, J.; Abdul-Redah, T.; Stirling, W.G.; Andreani, C.; Senesi, R.; Nardone, M.; Colognesi, D.; Degiorgi, E.

    2004-01-01

    The VESUVIO spectrometer at the ISIS pulsed neutron source performs inelastic neutron scattering at high-energy and wave vector transfers, employing gold and uranium resonant foils. A factor of two improvement in the instrumental resolution has been achieved by making use of the double filter difference method. Experimental results are presented for measurements on polycrystalline Pb, which indicate that accurate measurements of single-particle momentum distribution n(p) in quantum fluids are now possible at eV energy transfers

  3. VESUVIO--the double difference inverse geometry spectrometer at ISIS

    Energy Technology Data Exchange (ETDEWEB)

    Mayers, J.; Tomkinson, J.; Abdul-Redah, T.; Stirling, W.G.; Andreani, C.; Senesi, R.; Nardone, M.; Colognesi, D.; Degiorgi, E

    2004-07-15

    The VESUVIO spectrometer at the ISIS pulsed neutron source performs inelastic neutron scattering at high-energy and wave vector transfers, employing gold and uranium resonant foils. A factor of two improvement in the instrumental resolution has been achieved by making use of the double filter difference method. Experimental results are presented for measurements on polycrystalline Pb, which indicate that accurate measurements of single-particle momentum distribution n(p) in quantum fluids are now possible at eV energy transfers.

  4. VESUVIO-the double difference inverse geometry spectrometer at ISIS

    Science.gov (United States)

    Mayers, J.; Tomkinson, J.; Abdul-Redah, T.; Stirling, W. G.; Andreani, C.; Senesi, R.; Nardone, M.; Colognesi, D.; Degiorgi, E.

    2004-07-01

    The VESUVIO spectrometer at the ISIS pulsed neutron source performs inelastic neutron scattering at high-energy and wave vector transfers, employing gold and uranium resonant foils. A factor of two improvement in the instrumental resolution has been achieved by making use of the double filter difference method. Experimental results are presented for measurements on polycrystalline Pb, which indicate that accurate measurements of single-particle momentum distribution n(p) in quantum fluids are now possible at eV energy transfers.

  5. Wide-range scintillation spectrometer of fast neutrons

    International Nuclear Information System (INIS)

    Blinov, M.V.; Gavrilov, B.P.; Ivannikova, L.L.; Kozulin, Eh.M.; Mozhaev, A.N.; Saidgareev, V.M.; Tyurin, G.P.

    1984-01-01

    A spectrometer of fast neutrons developed on the base of stilbene crystas and permitting to detect neutrons simultaneously by time-of-flight and recoil protons with analysis of pulse shape in the 0.5-50 MeV energy range is described. The detecting part is performed in the CAMAC standard. The ''Minsk-32'' computer was used for data storage and preliminary processing

  6. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  7. Commissioning of a proton-recoil spectrometer

    International Nuclear Information System (INIS)

    Nunes, J.C.; Faught, R.T.

    2000-01-01

    Measurements of neutron fluence spectra in fields from bare and heavy-water-moderated 252 Cf were made with a commercially available proton-recoil spectrometer (PRS) that covers 50 keV to 4.5 MeV. Data obtained from these measurements were compared with data from Bonner sphere spectrometry, Monte Carlo simulation and the open literature. Alterations to the input data file used in unfolding recoil-proton pulse-height distributions were made. Understanding the reasons for these changes and considering the effects of some of the results in an appreciation of the significance of parameters used in the unfolding. An uncertainty of 10% is estimated for values of fluence and ambient dose equivalent for the energy region covered by this PRS. (author)

  8. Alpha particles spectrometer with photodiode PIN

    International Nuclear Information System (INIS)

    Chacon R, A.; Hernandez V, R.; Hernandez D, V. M.; Vega C, H. R.; Ramirez G, J.

    2009-10-01

    The radiation propagates in form of electromagnetic waves or corpuscular radiation; if the radiation energy causes ionization in environment that crosses it is considered ionizing radiation. To detect radiation several detectors types are used, if the radiation are alpha particles are used detectors proportional type or trace elements. In this work the design results, construction and tests of an alpha particles spectrometer are presented, which was designed starting from a photodiode PIN type. The system design was simulated with a code for electronic circuits. With results of simulation phase was constructed the electronic phase that is coupled to a multichannel analyzer. The resulting electronic is evaluated analyzing the electronic circuit performance before an alphas triple source and alpha radiation that produce two smoke detectors of domestic use. On the tests phase we find that the system allows obtain, in a multichannel, the pulses height spectrum, with which we calibrate the system. (Author)

  9. Geometrically weighted semiconductor Frisch grid radiation spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, D.S. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Rojeski, R.A. [Etec Systems, Inc., 26460 Corporate Ave., Hayward, CA 94545 (United States); He, Z. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Wehe, D.K. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Driver, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States); Blakely, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States)

    1999-02-11

    A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correction, and it requires only one signal output to any commercially available charge sensitive preamplifier. The device operates very well with conventional NIM electronic systems. Presently, room temperature (23 deg. C) energy resolutions of 2.68% FWHM at 662 keV and 2.45% FWHM at 1.332 MeV have been measured with a 1 cm{sup 3} prism shaped CdZnTe device.

  10. Einstein-Podolsky-Rosen paradox and quantum steering in pulsed optomechanics

    Science.gov (United States)

    He, Q. Y.; Reid, M. D.

    2013-11-01

    We describe how to generate an Einstein-Podolsky-Rosen (EPR) paradox between a mesoscopic mechanical oscillator and an optical pulse. We find two types of paradox, defined by whether it is the oscillator or the pulse that shows the effect Schrödinger called “steering”. Only the oscillator paradox addresses the question of mesoscopic local reality for a massive system. In that case, EPR's “elements of reality” are defined for the oscillator, and it is these elements of reality that are falsified (if quantum mechanics is complete). For this sort of paradox, we show that a thermal barrier exists, meaning that a threshold level of pulse-oscillator interaction is required for a given thermal occupation n0 of the oscillator. We find there is no equivalent thermal barrier for the entanglement of the pulse with the oscillator or for the EPR paradox that addresses the local reality of the optical system. Finally, we examine the possibility of an EPR paradox between two entangled oscillators. Our work highlights the asymmetrical effect of thermal noise on quantum nonlocality.

  11. CAMAC differential pulse discriminator-counter

    International Nuclear Information System (INIS)

    Tselikov, N.V.

    1987-01-01

    Differential pulse discriminator-counter for Moessbauer spectrometer is described. Input pulse setting into the channel is performed according to the following algorithm: the pulse is transmitted to the channel depending on the fact whether the preceding pulse has got to the discrimination window or not. The circuit does not contain delay lines, taking into account the delay of a signal from the upper level discriminator in relation to the lower level discriminator signal, which is connected with input pulse rise finite time, which in turn allows one to reduce the discriminator dead time up to the operation time of threshold circuits. The pulse counting rate is 150 MHz, input signal amplitude is ±3 V, dead time is 6 ns, delay time from input to output is 14 ns. The unit is made in CAMAC system

  12. VEGAS: VErsatile GBT Astronomical Spectrometer

    Science.gov (United States)

    Bussa, Srikanth; VEGAS Development Team

    2012-01-01

    The National Science Foundation Advanced Technologies and Instrumentation (NSF-ATI) program is funding a new spectrometer backend for the Green Bank Telescope (GBT). This spectrometer is being built by the CICADA collaboration - collaboration between the National Radio Astronomy Observatory (NRAO) and the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California Berkeley.The backend is named as VErsatile GBT Astronomical Spectrometer (VEGAS) and will replace the capabilities of the existing spectrometers. This backend supports data processing from focal plane array systems. The spectrometer will be capable of processing up to 1.25 GHz bandwidth from 8 dual polarized beams or a bandwidth up to 10 GHz from a dual polarized beam.The spectrometer will be using 8-bit analog to digital converters (ADC), which gives a better dynamic range than existing GBT spectrometers. There will be 8 tunable digital sub-bands within the 1.25 GHz bandwidth, which will enhance the capability of simultaneous observation of multiple spectral transitions. The maximum spectral dump rate to disk will be about 0.5 msec. The vastly enhanced backend capabilities will support several science projects with the GBT. The projects include mapping temperature and density structure of molecular clouds; searches for organic molecules in the interstellar medium; determination of the fundamental constants of our evolving Universe; red-shifted spectral features from galaxies across cosmic time and survey for pulsars in the extreme gravitational environment of the Galactic Center.

  13. Respiratory mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mostert, J.W. (Pretoria Univ. (South Africa). Dept. of Anesthesiology)

    1983-06-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M/sup 2/ body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O/sub 2/ consumption of less than 50 ml O/sub 2//min/M/sup 2/) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery.

  14. The respiratory mass spectrometer

    International Nuclear Information System (INIS)

    Mostert, J.W.

    1983-01-01

    The high degree of technical perfection of the respiratory mass spectrometer has rendered the instrument feasible for routine monitoring of anesthetized patients. It is proposed that the difference between inspired and expired oxygen tension in mm Hg be equated with whole body oxygen consumption in ml/min/M 2 body-surface area at STPD, by the expedient of multiplying tension-differences by a factor of 2. Years of experience have confirmed the value of promptly recognizing sudden drops in this l/E tension difference below 50 mm Hg indicative of metabolic injury from hypovolemia or respiratory depression. Rises in l/E tension-differences were associated with shivering as well as voluntary muscle activity. Tension differences of less than 25 mm Hg (equated with a whole-body O 2 consumption of less than 50 ml O 2 /min/M 2 ) occurred in a patient in the sitting position for posterior fossa exploration without acidosis, hypoxia or hypotension for several hours prior to irreversible cardiac arrest. The value of clinical monitoring by mass spectrometry is especially impressive in open-heart surgery

  15. UCN gravitational spectrometer

    International Nuclear Information System (INIS)

    Kawabata, Yuji

    1988-01-01

    Concept design is carried out of two types of ultra cold neutron scallering equipment using the fall-focusing principle. One of the systems comprises a vertical gravitational spectrometer and the other includes a horizontal gravitation analyzer. A study is made of their performance and the following results are obtained. Fall-focusing type ultra cold neutron scattering equipment can achieve a high accuracy for measurement of energy and momentum. Compared with conventional neutron scattering systems, this type of equipment can use neutron very efficiently because scattered neutrons within a larger solid angle can be used. The maximum solid angle is nearly 4π and 2π for the vertical and horizontal type, respectively. Another feature is that the size of equipment can be reduced. In the present concept design, the equipment is spherical with a diameter of about 1 m, as compared with NESSIE which is 6.7 m in length and 4.85 m in height with about the same accuracy. Two horizontal analyzers and a vertical spectroscope are proposed. They are suitable for angle-dependent non-elastic scattering in the neutron velocity range of 6∼15 m/s, pure elastic scattering in the range of 4∼7 m/s, or angle-integration non-elastic scattering in the range of 4∼15 m/s. (N.K.)

  16. Interpretation of the parameters of the EPR spectra of transition metal complexes

    International Nuclear Information System (INIS)

    Murav'ev, V.I.

    2005-01-01

    The calculated parameters of the EPR spectra of complexes of d 1 and d 9 ions, inclusive of MoOX 5 (X = Cl, Br), are reviewed. The covalent bond parameters used in the calculations were determined from EPR and experimental optical data (inverse problem of EPR spectroscopy). Various contributions to the expressions for the EPR parameters were compared. The observed abnormal values of the EPR parameters were discussed. The effects of charge-transfer states and the vibronic coupling on the components of g, A, and A L tensors were considered. Mechanisms of spin density transfer to ligands in paramagnetic complexes were proposed [ru

  17. Electrical transport and EPR investigations: A comparative study for ...

    Indian Academy of Sciences (India)

    did not have relatively such a high conductivity, skin depth was expected to be more than 1 μm. On the basis of g-values, line width, line shape behaviour and earlier observations by other researchers (Lux 1994;. Luthra et al 2003; Krinichnyi et al 2006), the EPR signal obtained has been assigned due to polarons (Bredas.

  18. Antioxidant Capacity: Experimental Determination by EPR Spectroscopy and Mathematical Modeling.

    Science.gov (United States)

    Polak, Justyna; Bartoszek, Mariola; Chorążewski, Mirosław

    2015-07-22

    A new method of determining antioxidant capacity based on a mathematical model is presented in this paper. The model was fitted to 1000 data points of electron paramagnetic resonance (EPR) spectroscopy measurements of various food product samples such as tea, wine, juice, and herbs with Trolox equivalent antioxidant capacity (TEAC) values from 20 to 2000 μmol TE/100 mL. The proposed mathematical equation allows for a determination of TEAC of food products based on a single EPR spectroscopy measurement. The model was tested on the basis of 80 EPR spectroscopy measurements of herbs, tea, coffee, and juice samples. The proposed model works for both strong and weak antioxidants (TEAC values from 21 to 2347 μmol TE/100 mL). The determination coefficient between TEAC values obtained experimentally and TEAC values calculated with proposed mathematical equation was found to be R(2) = 0.98. Therefore, the proposed new method of TEAC determination based on a mathematical model is a good alternative to the standard EPR method due to its being fast, accurate, inexpensive, and simple to perform.

  19. A fast method for ionized food identification: EPR

    International Nuclear Information System (INIS)

    Raffi, J.; Rubel, G.

    1990-01-01

    Electronic paramagnetic resonance allows the detection of ionized food only after dry storage, avoiding reaction of radicals with water. Dry and solid parts are used for analysis (bones for meat and fish, kernels for fruits). Dosimetry is possible by EPR spectrometry of alanine-L fixed on products treated in industrial irradiators [fr

  20. Isothermal annealing kinetics of X-irradiated pyrene by EPR

    International Nuclear Information System (INIS)

    Partiti, C.S.M.; Pontuschka, W.M.; Fazzio, A.; Piccini, A.

    1989-07-01

    The annealing behavior of X-irradiated stable free radicals found in Pyrene (C 16 H 10 ) single crystals was studied by EPR. Two processes of thermal decay kinetics were found, both with the same activation energy (1.9±0.1) ev. (author) [pt