WorldWideScience

Sample records for pulsed magnetic fields

  1. Magnetization reversal in ultrashort magnetic field pulses

    CERN Document Server

    Bauer, M; Fassbender, J; Hillebrands, B

    2000-01-01

    We report the switching properties of a thin magnetic film subject to an ultrashort, laterally localized magnetic field pulse, obtained by numerical investigations. The magnetization distribution in the film is calculated on a grid assuming Stoner-like coherent rotation within the grid square size. Perpendicularly and in-plane magnetized films exhibit a magnetization reversal due to a 4 ps magnetic field pulse. Outside the central region the pulse duration is short compared to the precession period. In this area the evolution of the magnetization during the field pulse does not depend strongly on magnetic damping and/or pulse shape. However, the final magnetization distribution is affected by the magnetic damping. Although the pulse duration is short compared to the precession period, the time needed for the relaxation of the magnetization to the equilibrium state is rather large. The influence of the different magnetic anisotropy contributions and the magnetic damping parameter enters into the magnetization ...

  2. NMR in pulsed magnetic field

    KAUST Repository

    Abou-Hamad, Edy

    2011-09-01

    Nuclear magnetic resonance (NMR) experiments in pulsed magnetic fields up to 30.4 T focused on 1H and 93Nb nuclei are reported. Here we discuss the advantage and limitation of pulsed field NMR and why this technique is able to become a promising research tool. © 2011 Elsevier Inc. All Rights Reserved.

  3. Strong and superstrong pulsed magnetic fields generation

    CERN Document Server

    Shneerson, German A; Krivosheev, Sergey I

    2014-01-01

    Strong pulsed magnetic fields are important for several fields in physics and engineering, such as power generation and accelerator facilities. Basic aspects of the generation of strong and superstrong pulsed magnetic fields technique are given, including the physics and hydrodynamics of the conductors interacting with the field as well as an account of the significant progress in generation of strong magnetic fields using the magnetic accumulation technique. Results of computer simulations as well as a survey of available field technology are completing the volume.

  4. Wuhan pulsed high magnetic field center

    OpenAIRE

    Li, Liang; Peng, Tao; Ding, Honfa; Han, Xiaotao; Ding, Tonghai; Chen, Jin; Wang, Junfeng; Xie, Jianfeng; Wang, Shaoliang; Duan, Xianzhong; Wang, Cheng; Herlach, Fritz; Vanacken, Johan; Pan, Yuan

    2008-01-01

    Wuhan pulsed high magnetic field facility is under development. Magnets of bore sizes from 12 to 34 mm with the peak field in the range of 50 to 80 T have been designed. The pulsed power supplies consists of a 12 MJ, 25 kV capacitor bank and a 100 MVA/100 MJ flywheel pulse generator. A prototype 1 MJ, 25 kV capacitor bank is under construction. Five magnets wound with CuNb wire and copper wire reinforced internally with Zylon fiber composites and externally with stainless steel shells have be...

  5. Wuhan pulsed high magnetic field center

    OpenAIRE

    Li, Liang; Peng, Tao; Ding, Honfa; Han, Xiaotao; Ding, Tonghai; Chen, Jin; Wang, Junfeng; Xie, Jianfeng; Wang, Shaoliang; DUAN, Xianzhong; Wang, Cheng; Herlach, Fritz; Vanacken, Johan; Pan, Yuan

    2008-01-01

    Wuhan pulsed high magnetic field facility is under development. Magnets of bore sizes from 12 to 34 mm with the peak field in the range of 50 to 80 T have been designed. The pulsed power supplies consists of a 12 MJ, 25 kV capacitor bank and a 100 MVA/100 MJ flywheel pulse generator. A prototype 1 MJ, 25 kV capacitor bank is under construction. Five magnets wound with CuNb wire and copper wire reinforced internally with Zylon fiber composites and externally with stainless steel shells have be...

  6. Magnetic Linear Birefringence Measurements Using Pulsed Fields

    CERN Document Server

    Berceau, Paul; Battesti, Remy; Rizzo, Carlo

    2011-01-01

    In this paper we present the accomplishment of the further step towards the vacuum magnetic birefringence measurement based on pulsed fields. After describing our BMV experiment, we report the calibration of our apparatus with nitrogen gas and we discuss the precision of our measurement giving a detailed error budget. Our best present vacuum sensitivity is 2.1x 10^-19 T^-2 per 5 ms magnetic pulse. We finally discuss the perspectives to reach our final goal.

  7. High Field Pulse Magnets with New Materials

    Science.gov (United States)

    Li, L.; Lesch, B.; Cochran, V. G.; Eyssa, Y.; Tozer, S.; Mielke, C. H.; Rickel, D.; van Sciver, S. W.; Schneider-Muntau, H. J.

    2004-11-01

    High performance pulse magnets using the combination of CuNb conductor and Zylon fiber composite reinforcement with bore sizes of 24, 15 and 10 mm have been designed, manufactured and tested to destruction. The magnets successfully reached the peak fields of 64, 70 and 77.8 T respectively with no destruction. Failures occurred near the end flanges at the layer. The magnet design, manufacturing and testing, and the mode of the failure are described and analyzed.

  8. Pulsed-field magnetometry for rock magnetism

    Science.gov (United States)

    Kodama, Kazuto

    2015-07-01

    An improved method is proposed for measuring dynamic magnetizations of bulk volcanic rock samples induced by a pulsed-field of 0.7 T and a duration of 10 ms. The transient magnetization is measured by a sensing system that consists of a pair of inductive differential coils, an analog preamplifier and integrator, and a high-speed digital storage scope. The system was calibrated using a paramagnetic salt (Gd2O3) and was tested to different kinds of volcanic rocks with their magnetic properties well-documented previously. The results were comparable with those measured by a quasi-static method using a vibrating sample magnetometer, although there were small discrepancies in hysteresis parameters suggesting the time-dependence of the magnetic properties. The proposed system provides not only the magnetization over the short interval of a pulse but also the rapid (~3 ms) exponential decay after a pulse. The decay time constant was different among the samples under study, indicating the variations of their magnetic relaxation time. Although the present system is not sensitive enough to characterize varieties of natural samples including sediments, it has the potential as a versatile and convenient tool for rock magnetism.

  9. Trapped magnetic field measurements on HTS bulk by peak controlled pulsed field magnetization

    Energy Technology Data Exchange (ETDEWEB)

    Ida, Tetsuya; Watasaki, Masahiro [Department of Electronic Control Engineering, Hiroshima National College of Maritime Technology, 4272-1, Higashino, Ohsakikamijima-cho, Toyota-gun, Hiroshima 725-0231 (Japan); Kimura, Yosuke [Kawasaki Heavy Industries, Ltd. Technical Institute System Technology Development Centre 1-1, Kawasaki-cho, Akashi-shi, Hyogo 673-8666 (Japan); Miki, Motohiro; Izumi, Mitsuru, E-mail: ida@hiroshima-cmt.ac.j [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan)

    2010-06-01

    For the past several years, we have studied the high-temperature superconducting (HTS) synchronous motor assembled with melt-textured Gd-Ba-Cu-O bulk magnets. If the single pulse field magnetizes a bulk effectively, size of electrical motor will become small for the strong magnetic field of the HTS magnets without reducing output power of motor. In the previous study, we showed that the HTS bulk was magnetized to excellent cone-shape magnetic field distribution by using the waveform control pulse magnetization (WCPM) method. The WCPM technique made possible the active control of the waveform on which magnetic flux motion depended. We generated the pulse waveform with controlled risetime for HTS bulk magnetization to suppress the magnetic flux motion which decreases magnetization efficiency. The pulsed maximum magnetic flux density with slow risetime is not beyond the maximum magnetic flux density which is trapped by the static field magnetization. But, as for applying the pulse which has fast risetime, the magnetic flux which exceed greatly the threshold penetrates the bulk and causes the disorder of the trapped magnetic distribution. This fact suggests the possibility that the threshold at pulsed magnetization influences the dynamic magnetic flux motion. In this study, Gd-Ba-Cu-O bulk is magnetized by the controlled arbitrary trapezoidal shape pulse, of which the maximum magnetic flux density is controlled not to exceed the threshold. We will present the trapped magnetic characteristics and the technique to generate the controlled pulsed field.

  10. Design of Pulsed Strong Magnetic Fields Generator and Preliminary Application

    Institute of Scientific and Technical Information of China (English)

    WEN Jun; QU Xue-min; WANG Xi-gang; LONG Kai-ping

    2015-01-01

    Objective: This paper aims to designing a pulsed strong magnetic fields generator. Methods: A large value capacitor was used to store electric energy, coil was used for producing magnetic fields, main control, circuit control charge, sampling, discharge, etc. Results: The generator provided a pulsed magnetic field with the ampli-tude of intensity from 0.1-2 T and variable time interval of pulse from 4 s-1 min. It was not only to be operated easily but also performed reliably. Conclusion:The generator will be applied in special clinical diagnosis, therapy and other fields.

  11. Successful suppression of magnetization precession after short field pulses

    OpenAIRE

    Bauer, Martin; Lopusnik, Radek; Fassbender, Jürgen; Hillebrands, Burkard; Dötsch, H.

    2000-01-01

    For the next generation of high data rate magnetic recording above 1 Gbit/s, a better understanding of the switching processes for both recording heads and media will be required. In order to maximize the switch-ing speed for such devices, the magnetization precession after the magnetic field pulse termination needs to be suppressed to a maximum degree. It is demonstrated experimentally for ferrite films that the appropriate adjustment of the field pulse parameters and/or the static applied f...

  12. Microscopic Faraday rotation measurement system using pulsed magnetic fields.

    Science.gov (United States)

    Egami, Shigeki; Watarai, Hitoshi

    2009-09-01

    Microscopic Faraday rotation measurement system using a pulsed magnetic field has been constructed, which can be applied to micron sized diamagnetic and paramagnetic materials. A pulsed magnetic coil could generate a maximum magnetic flux density of about 12 T. The performance of the microscopic Faraday rotation apparatus was demonstrated by the measurement of the Verdet constant V of a polystyrene particle, after the calibration of the pulsed magnetic flux density using a glass plate as a standard material. Also, the magneto-optical rotation dispersion of some diamagnetic substances have been measured and analyzed with V=alambda(-2)+b. The values of a and b were compared to their magnetic susceptibilities.

  13. Heat pulse propagation in chaotic 3-dimensional magnetic fields

    CERN Document Server

    del-Castillo-Negrete, D

    2014-01-01

    Heat pulse propagation in $3$-D chaotic magnetic fields is studied by solving the parallel heat transport equation using a Lagrangian-Green's function (LG) method. The LG method provides an efficient and accurate technique that circumvents limitations of finite elements and finite difference methods. The main two problems addressed are: (i) The dependence of the radial transport on the magnetic field stochasticity (controlled by the amplitude of the perturbation, $\\epsilon$); and (ii) The role of reversed shear configurations on pulse propagation. In all the cases considered there are no magnetic flux surfaces. However, radial transport is observed to depend strongly on $\\epsilon$ due to the presence of high-order magnetic islands and Cantori that act as quasi-transport barriers that preclude the radial penetration of heat pulses within physically relevant time scale. The dependence of the magnetic field connection length, $\\ell_B$, on $\\epsilon$ is studied in detail. The decay rate of the temperature maximum...

  14. Miniature coils for producing pulsed inplane magnetic fields for nanospintronics

    Energy Technology Data Exchange (ETDEWEB)

    Pawliszak, Łukasz; Zgirski, Maciej [Institute of Physics, Polish Academy of Sciences, al.Lotnikow 32/46, PL 02-668 Warszawa (Poland); Tekielak, Maria [Faculty of Physics, University of Białystok, ul.Lipowa 41, PL 15-424 Białystok (Poland)

    2015-03-15

    Nanospintronic and related research often requires the application of quickly rising magnetic field pulses in the plane of the studied planar structure. We have designed and fabricated sub-millimeter-sized coils capable of delivering pulses of the magnetic field up to ∼500 Oe in the plane of the sample with the rise time of the order of 10 ns. The placement of the sample above the coil allows for easy access to its surface with manipulators or light beams for, e.g., Kerr microscopy. We use the fabricated coil to drive magnetic domain walls in 1 μm wide permalloy wires and measure magnetic domain wall velocity as a function of the applied magnetic field.

  15. Pulsed Field Waveforms for Magnetization of HTS Gd-Ba-Cu-O Bulk Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ida, T [Department of Electronic Control Engineering, Hiroshima National College of Maritime Technology, 4272-1, Higashino, Ohsakikamijima-cho, Toyota-gun, Hiroshima 725-0231 (Japan); Matsuzaki, H [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Morita, E [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Sakashita, H [Department of Electronic Control Engineering, Hiroshima National College of Maritime Technology, 4272-1, Higashino, Ohsakikamijima-cho, Toyota-gun, Hiroshima 725-0231 (Japan); Harada, T [Department of Electronic Control Engineering, Hiroshima National College of Maritime Technology, 4272-1, Higashino, Ohsakikamijima-cho, Toyota-gun, Hiroshima 725-0231 (Japan); Ogata, H [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Kimura, Y [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Miki, M [Kitano Seiki Co. Ltd., 7-13-7, Chuo, Ohta-ku, Tokyo 143-0024 (Japan); Kitano, M [Kitano Seiki Co. Ltd., 7-13-7, Chuo, Ohta-ku, Tokyo 143-0024 (Japan); Izumi, M [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan)

    2006-06-01

    Progress in pulse magnetization technique for high-temperature superconductor bulks of melt-textured RE-Ba-Cu-O with large diameter is important for the realization of power applications. We studied the pulsed power source and pulsed field waveforms to enhance to improve the magnetization properties for Gd-Ba-Cu-O bulk. The risetime and duration of pulse waveform effectively varied distribution of magnetic flux.

  16. Penetration dynamics of a magnetic field pulse into high-? superconductors

    Science.gov (United States)

    Meerovich, V.; Sinder, M.; Sokolovsky, V.; Goren, S.; Jung, G.; Shter, G. E.; Grader, G. S.

    1996-12-01

    The penetration of a magnetic field pulse into a high-0953-2048/9/12/004/img9 superconducting plate is investigated experimentally and theoretically. It follows from our experiments that the threshold of penetration increases with increasing amplitude and/or decreasing duration of the applied pulse. The penetrating field continues to grow as the applied magnetic field decreases. The peculiarities observed are explained in the framework of the extended critical state model. It appears that the deviations from Bean's classical critical state model are characterized by a parameter equal to the square of the ratio of plate thickness to skin depth. The applicability of the classical critical state model is restricted by the condition that this parameter is much less than 1. This condition is also the criterion for the applicability of pulse methods of critical current measurements.

  17. Long-pulse magnetic field facility at Zaragoza

    Science.gov (United States)

    Algarabel, P. A.; del Moral, A.; Martín, C.; Serrate, D.; Tokarz, W.

    2006-11-01

    The long-pulse magnetic field facility of the Laboratorio de Magnetismo - Instituto de Ciencia de Materiales de Aragón (Universidad de Zaragoza-CSIC) produces magnetic fields up to 31, with a pulse duration of 2.2s. Experimental set-ups for measurements of magnetization, magnetostriction and magnetoresistance are available. The temperature can be controlled between 1.4 and 335 K, being the inner bore of the He cryostat of 22.5 mm. Magnetization is measured using the mutual induction technique, the magnetostriction is determined with the strain-gage and the capacitive cantilever methods, and the magnetoresistance is measured by means of the aclock-in technique in the 4-probes geometry. An overview of the facility will be presented and the presently available experimental techniques will be discussed.

  18. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    Science.gov (United States)

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  19. Pulsed field magnetization in rare-earth kagome systems

    Science.gov (United States)

    Hoch, M. J. R.; Zhou, H. D.; Mun, E.; Harrison, N.

    2016-02-01

    The rare-earth kagome systems R 3Ga5SiO14 (R  =  Nd or Pr) exhibit cooperative paramagnetism at low temperatures. Evidence for correlated spin clusters in these weakly frustrated systems has previously been obtained from neutron scattering and from ESR and NMR results. The present pulsed field (0-60 T, 25 ms) magnetization measurements made on single crystals of Nd3Ga5SiO14 (NGS) and Pr3Ga5SiO14 (PGS) at temperatures down to 450 mK have revealed striking differences in the magnetic responses of the two materials. For NGS the magnetization shows a low field plateau, saturation in high transient fields, and significant hysteresis while the PGS magnetization does not saturate in transient fields up to 60 T and shows no hysteresis or plateaus. Nd3+ is a Kramers ion while Pr3+ is a non-Kramers ion and the crystal field effects are quite different in the two systems. For the conditions used in the experiments the magnetization behavior is not in agreement with Heisenberg model predictions for kagome systems in which easy-axis anisotropy is much larger than the exchange coupling. The extremely slow spin dynamics found below 4 K in NGS is, however, consistent with the model for Kramers ions and provides a basis for explaining the pulsed field magnetization features.

  20. Pulsed field magnetization in rare-earth kagome systems.

    Science.gov (United States)

    Hoch, M J R; Zhou, H D; Mun, E; Harrison, N

    2016-02-03

    The rare-earth kagome systems R 3Ga5SiO14 (R  =  Nd or Pr) exhibit cooperative paramagnetism at low temperatures. Evidence for correlated spin clusters in these weakly frustrated systems has previously been obtained from neutron scattering and from ESR and NMR results. The present pulsed field (0-60 T, 25 ms) magnetization measurements made on single crystals of Nd3Ga5SiO14 (NGS) and Pr3Ga5SiO14 (PGS) at temperatures down to 450 mK have revealed striking differences in the magnetic responses of the two materials. For NGS the magnetization shows a low field plateau, saturation in high transient fields, and significant hysteresis while the PGS magnetization does not saturate in transient fields up to 60 T and shows no hysteresis or plateaus. Nd(3+) is a Kramers ion while Pr(3+) is a non-Kramers ion and the crystal field effects are quite different in the two systems. For the conditions used in the experiments the magnetization behavior is not in agreement with Heisenberg model predictions for kagome systems in which easy-axis anisotropy is much larger than the exchange coupling. The extremely slow spin dynamics found below 4 K in NGS is, however, consistent with the model for Kramers ions and provides a basis for explaining the pulsed field magnetization features.

  1. A 7 T Pulsed Magnetic Field Generator for Magnetized Laser Plasma Experiments

    Science.gov (United States)

    Hu, Guangyue; Liang, Yihan; Song, Falun; Yuan, Peng; Wang, Yulin; Zhao, Bin; Zheng, Jian

    2015-02-01

    A pulsed magnetic field generator was developed to study the effect of a magnetic field on the evolution of a laser-generated plasma. A 40 kV pulsed power system delivered a fast (~230 ns), 55 kA current pulse into a single-turn coil surrounding the laser target, using a capacitor bank of 200 nF, a laser-triggered switch and a low-impedance strip transmission line. A one-dimensional uniform 7 T pulsed magnetic field was created using a Helmholtz coil pair with a 6 mm diameter. The pulsed magnetic field was controlled to take effect synchronously with a nanosecond heating laser beam, a femtosecond probing laser beam and an optical Intensified Charge Coupled Device (ICCD) detector. The preliminary experiments demonstrate bifurcation and focusing of plasma expansion in a transverse magnetic field.

  2. Effects of an external magnetic field in pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, T. [Universidad Autonoma de la Ciudad de Mexico (UACM), Prolongacion San Isidro 151, Col. San Lorenzo Tezonco, C.P. 09790, Mexico DF (Mexico)], E-mail: tupacgarcia@yahoo.com; Posada, E. de [CINVESTAV-IPN Unidad Merida, Applied Physics Department, A.P. 73, Cordemex, C.P. 97130 Merida, Yuc. (Mexico); Villagran, M. [CCADET, Universidad Nacional Autonoma de Mexico (UNAM), A.P. 70-186, C.P. 04510, Mexico DF (Mexico); Ll, J.L. Sanchez [Laboratorio de Magnetismo, Facultad de Fisica-IMRE, Universidad de La Habana, La Habana 10400 (Cuba); Bartolo-Perez, P.; Pena, J.L. [CINVESTAV-IPN Unidad Merida, Applied Physics Department, A.P. 73, Cordemex, C.P. 97130 Merida, Yuc. (Mexico)

    2008-12-30

    Thin films were grown by pulsed laser deposition, PLD, on Si (1 0 0) substrates by the ablation of a sintered ceramic SrFe{sub 12}O{sub 19} target with and without the presence of a nonhomogeneous magnetic field of {mu}{sub 0}H = 0.4 T perpendicular to substrate plane and parallel to the plasma expansion axis. The field was produced by a rectangular-shaped Nd-Fe-B permanent magnet and the substrate was just placed on the magnet surface (Aurora method). An appreciable increment of optical emission due to the presence of the magnetic field was observed, but no film composition change or thickness increment was obtained. It suggests that the increment of the optical emission is due mainly to the electron confinement rather than confinement of ionic species.

  3. Trapped field measurements of Gd-Ba-Cu-O bulk superconductor in controlled pulse field magnetizing

    Energy Technology Data Exchange (ETDEWEB)

    Ida, T [Department of Electronic Control Engineering, Hiroshima National College of Maritime Technology, 4272-1, Higashino, Ohsakikamijima-cho, Toyota-gun, Hiroshima 725-0231 (Japan); Kimura, Y; Sano, T; Yamaguchi, K; Izumi, M [Department of Marine Electronics and Mechanical Engineering, Tokyo University of Marine Science and Technology, 2-1-6, Etchu-jima, Koto-ku, Tokyo 135-8533 (Japan); Miki, M [Kitano Seiki Co. Ltd., 7-13-7, Chuo, Ohta-ku, Tokyo 143-0024 (Japan)], E-mail: ida@hiroshima-cmt.ac.jp

    2008-02-01

    For large-scale electric power application of the melt-processed high temperature superconductor (HTS) bulks, especially at rotating machine, development of trapping much higher magnetic fields by using pulsed magnetization technique is essential. It is difficult to use static field cooling (FCM) technique that is most effective magnetizing method for the general industrial HTS applications, because the FCM requires large-scale superconducting magnets. Because the rise in temperature due to the magnetic flux motion decreases the pinning force, we controlled the magnetic flux penetrating to the bulk for the effective magnetization. A couple of vortex-type copper coils applied a magnetic field to a Gd-Ba-Cu-O bulk, which dimension was 45mm in diameter and 19 mm in thickness. HTS bulk was magnetized by the controlled pulse field without passive LCR pulse. We controlled waveform by using the discharge current that IGBT chopper in pulse magnetizer intermitted. We applied the pulse magnetic field with the various risetime to the HTS bulk in liquid nitrogen. The various conditions of the controlled waveform pulse to trap well-dressed profile magnetized the Gd-Ba-Cu-O bulk, strongly at 77K. In the present study, we show several properties which was measured in the PFM of the HTS bulk.

  4. Vacuum magnetic linear birefringence using pulsed fields: the BMV experiment

    CERN Document Server

    Cadène, A; Fouché, M; Battesti, R; Rizzo, C

    2013-01-01

    In this letter we present the measurement of the vacuum magnetic birefringence obtained using the first generation setup of the BMV experiment. In particular, we detail our procedure of data acquisition and our analysis which takes into account the symmetry properties of raw data with respect to the orientation of the magnetic field and the sign of the cavity birefringence. Our current value of vacuum magnetic linear birefringence k_CM was obtained with about 100 magnetic pulses and a maximum field of 6.5 T. We get k_CM = (-7.4 \\pm 8.7).10^{-21} T^{-2} at 3 sigma confidence level. Our result is a clear validation of our innovative experimental method.

  5. Generation and measurement of pulsed high magnetic field

    CERN Document Server

    Jana, S

    2000-01-01

    Pulsed magnetic field has been generated by discharging a capacitor bank through a 5-layer air-core solenoid. The strength of the magnetic field at its peak has been measured using the voltage induced in various pick-up coils, and also from the Zeeman splitting of an ion having a known g value. Synchronizing a xenon flash at the peak of the magnetic field, this lab-made instrument has been made well suited to study the Zeeman effect, etc. at a temperature of 25 K. As an application of this setup, we have investigated the Zeeman splitting of the sup 4 I sub 9 sub / sub 2-> sup 4 G sub 5 sub / sub 2 transition of the Nd sup 3 sup + -doped CsCdCl sub 3 crystal at 7.8 T, and determined the splitting factors.

  6. Ultra-fast ballistic magnetization reversal triggered by a single magnetic field pulse

    Energy Technology Data Exchange (ETDEWEB)

    Horley, Paul P; Gonzalez Hernandez, Jesus [Centro de Investigacion en Materiales Avanzados S.C., Chihuahua/Monterrey, Av. Miguel de Cervantes 120, 31109 Chihuahua, Chihuahua (Mexico); Vieira, Vitor R; Dugaev, Vitalii K [Centro de Fisica das Interaccoes Fundamentais, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal); Gorley, Peter [Department of Physics, Yuri Fedkovych Chernivtsi National University, 2 Kotsyubynsky Street, 58012 Chernivtsi (Ukraine); Barnas, Jozef, E-mail: paul.horley@cimav.edu.m [Institute of Molecular Physics, Polish Academy of Sciences, ul. Smoluchowskiego 17, 60-179 Poznan (Poland)

    2009-12-21

    Performance of devices such as magnetic random access memories crucially depends on magnetic switching time. By numerical simulations we show that ultra-fast (in the sub-nanosecond range) magnetic reversal in nanoparticles can be achieved with a single pulse of magnetic field oriented at some specific angles with respect to the magnetic moment. These angles form the areas of ballistic reversal (with no magnetization ringing). We show that the size of these areas increases with decreasing pulse duration, which allows reaching of the sub-nanosecond reversal for a pulse duration of the order of dozen(s) of ps. When changing the magnetic field, the areas of ballistic reversal move along the equator of the unitary sphere, and eventually merge with each other. For appropriate choice of the azimuthal angle, one can reach magnetic reversal along a trajectory located in or out of the easy plane.

  7. Maximum trapped field of a ring bulk superconductor by low pulsed field magnetization

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchimoto, M. [Hokkaido Institute of Technology, 7-15 Maeda, Teine-ku, Sapporo 006-8585 (Japan)], E-mail: tsuchi@hit.ac.jp; Kamijo, H. [Railway Technical Research Institute, 2-8-38, Hikari-cho, Kokubunji, Tokyo 185-8540 (Japan)

    2007-10-01

    Pulsed field magnetization is an important technique for a bulk superconducting magnet, which is one practical application of a bulk high T{sub c} superconductor (HTS). Full magnetization of a ring HTS is effective to obtain large trapped field for low pulsed field magnetization. In this study, trapped field in a ring bulk superconductor by the low pulsed field magnetization is numerically analyzed under assumption of variable shielding current by the temperature control. Differences between one-dimensional Bean model and axisymmetric three-dimensional numerical solution are discussed through the analysis. There is maximum trapped field in the axisymmetric three-dimensional model because of finite thickness of the ring HTS. The shielding current density and inner radius of the ring HTS are discussed to obtain the maximum trapped field.

  8. Trial Application of Pulse-Field Magnetization to Magnetically Levitated Conveyor System

    Directory of Open Access Journals (Sweden)

    Yoshihito Miyatake

    2012-01-01

    Full Text Available Magnetically levitated conveyor system using superconductors is discussed. The system is composed of a levitated conveyor, magnetic rails, a linear induction motor, and some power supplies. In the paper, pulse-field magnetization is applied to the system. Then, the levitation height and the dynamics of the conveyor are controlled. The static and dynamic characteristics of the levitated conveyor are discussed.

  9. Pulsed field probe of real time magnetization dynamics in magnetic nanoparticle systems

    Science.gov (United States)

    Foulkes, T.; Syed, M.; Taplin, T.

    2015-05-01

    Magnetic nanoparticles (MNPs) are extensively used in biotechnology. These applications rely on magnetic properties that are a keen function of MNP size, distribution, and shape. Various magneto-optical techniques, including Faraday Rotation (FR), Cotton-Mouton Effect, etc., have been employed to characterize magnetic properties of MNPs. Generally, these measurements employ AC or DC fields. In this work, we describe the results from a FR setup that uses pulsed magnetic fields and an analysis technique that makes use of the entire pulse shape to investigate size distribution and shape anisotropy. The setup employs a light source, polarizing components, and a detector that are used to measure the rotation of light from a sample that is subjected to a pulsed magnetic field. This magnetic field "snapshot" is recorded alongside the intensity pulse of the sample's response. This side by side comparison yields useful information about the real time magnetization dynamics of the system being probed. The setup is highly flexible with variable control of pulse length and peak magnitude. Examining the raw data for the response of bare Fe3O4 and hybrid Au and Fe3O4 nanorods reveals interesting information about Brownian relaxation and the hydrodynamic size of these nanorods. This analysis exploits the self-referencing nature of this measurement to highlight the impact of an applied field on creating a field induced transparency for a longitudinal measurement. Possible sources for this behavior include shape anisotropy and field assisted aggregate formation.

  10. Measurement of dynamic magnetization induced by a pulsed field: Proposal for a new rock magnetism method

    Science.gov (United States)

    Kodama, Kazuto

    2015-02-01

    This study proposes a new method for measuring transient magnetization of natural samples induced by a pulsed field with duration of 11 ms using a pulse magnetizer. An experimental system was constructed, consisting of a pair of differential sensing coils connected with a high-speed digital oscilloscope for data acquisition. The data were transferred to a computer to obtain an initial magnetization curve and a descending branch of a hysteresis loop in a rapidly changing positive field. This system was tested with synthetic samples (permalloy ribbon, aluminum plate, and nickel powder) as well as two volcanic rock samples. Results from the synthetic samples showed considerable differences from those measured by a quasi-static method using a vibrating sample magnetometer (VSM). These differences were principally due to the time-dependent magnetic properties or to electromagnetic effects, such as magnetic viscosity, eddy current loss, or magnetic relaxation. Results from the natural samples showed that the transient magnetization-field curves were largely comparable to the corresponding portions of the hysteresis loops. However, the relative magnetization (scaled to the saturation magnetization) at the end of a pulse was greater than that measured by a VSM. This discrepancy, together with the occurrence of rapid exponential decay after a pulse, indicates magnetic relaxations that could be interpreted in terms of domain wall displacement. These results suggest that with further developments, the proposed technique can become a useful tool for characterizing magnetic particles contained in a variety of natural materials.

  11. Measurement of dynamic magnetization induced by a pulsed field: Proposal for a new rock magnetism method

    Directory of Open Access Journals (Sweden)

    Kazuto eKodama

    2015-02-01

    Full Text Available This study proposes a new method for measuring transient magnetization of natural samples induced by a pulsed field with duration of 11 ms using a pulse magnetizer. An experimental system was constructed, consisting of a pair of differential sensing coils connected with a high-speed digital oscilloscope for data acquisition. The data were transferred to a computer to obtain an initial magnetization curve and a descending branch of a hysteresis loop in a rapidly changing positive field. This system was tested with synthetic samples (permalloy ribbon, aluminum plate, and nickel powder as well as two volcanic rock samples. Results from the synthetic samples showed considerable differences from those measured by a quasi-static method using a vibrating sample magnetometer (VSM. These differences were principally due to the time-dependent magnetic properties or to electromagnetic effects, such as magnetic viscosity, eddy current loss, or magnetic relaxation. Results from the natural samples showed that the transient magnetization–field curves were largely comparable to the corresponding portions of the hysteresis loops. However, the relative magnetization (scaled to the saturation magnetization at the end of a pulse was greater than that measured by a VSM. This discrepancy, together with the occurrence of rapid exponential decay after a pulse, indicates magnetic relaxations that could be interpreted in terms of domain wall displacement. These results suggest that with further developments, the proposed technique can become a useful tool for characterizing magnetic particles contained in a variety of natural materials.

  12. Pulsed field magnetization strategies and the field poles composition in a bulk-type superconducting motor

    Science.gov (United States)

    Huang, Zhen; Ruiz, H. S.; Coombs, T. A.

    2017-03-01

    High temperature superconducting (HTS) bulks offer the potential of trapping and maintaining much higher magnetic loading level compared with the conventional permanent magnets used in rotary machines, although the effective magnetization of multiple HTS bulks with different relative orientations over the surface of cylindrical rotors creates new challenges. In this paper, we present the design and numerical validation of the Pulse Field Magnetization (PFM) strategy considered for the magnetization of the four-pole synchronous fully superconducting motor developed at the University of Cambridge. In a first instance, singular columns of up to five HTS bulks aligned over the height of the rotor were subjected to up to three magnetic pulses of 1.5 T peak, and the experimental results have been simulated by considering the electrical and thermal properties of the system in a 2D approach. The entire active surface of the rotor is covered by HTS bulks of approximately the same dimensions, resulting in an uneven distribution of pole areas with at least one of the poles formed by up to 3 columns of magnetized bulks, with relatively the same peaks of trapped magnetic field. Thus, in order to effectively use the entire area of the superconducting rotor, multiple pulsed fields per column have been applied under the same experimental conditions, what results in about three times larger magnetic pole areas but with an average drop on the peaks of trapped magnetic field of about 50%.

  13. Neutron investigations of magnetic properties of crystal substances with use of a pulsed magnetic field

    CERN Document Server

    Nitts, V V

    2001-01-01

    Bases for neutron researches of magnetic properties of crystal substances with use of a pulsed magnetic field and analysis of possible application of various neutron sources in this area are submitted. The review of the most interesting physical results is presented. Main investigations on pulsed reactors of JINR are researches on kinetics of the first order reorientational phase transitions induced in single crystals, and also measurements of antiferromagnetic ordering induced by an external magnetic field. Magnetic phase transitions, induced by a field up to 160 kOe in several magnetic ordering substances, were studied in KEK (Japan). Experiment on observation of spin-flop transition in MnF sub 2 was carried out on TRIGA-reactor in a mode of single flashes of power

  14. Fast magnetic field annihilation driven by two laser pulses in underdense plasma

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Y. J.; Kumar, D.; Weber, S.; Korn, G. [Institute of Physics of the ASCR, ELI-Beamlines, 18221 Prague (Czech Republic); Klimo, O. [Institute of Physics of the ASCR, ELI-Beamlines, 18221 Prague (Czech Republic); FNSPE, Czech Technical University in Prague, 11519 Prague (Czech Republic); Bulanov, S. V.; Esirkepov, T. Zh. [Kansai Photon Science Institute, Japan Atomic Energy Agency, 8-1-7 Umemidai, Kizugawa-shi, Kyoto 619-0215 (Japan)

    2015-10-15

    Fast magnetic annihilation is investigated by using 2.5-dimensional particle-in-cell simulations of two parallel ultra-short petawatt laser pulses co-propagating in underdense plasma. The magnetic field generated by the laser pulses annihilates in a current sheet formed between the pulses. Magnetic field energy is converted to an inductive longitudinal electric field, which efficiently accelerates the electrons of the current sheet. This new regime of collisionless relativistic magnetic field annihilation with a timescale of tens of femtoseconds can be extended to near-critical and overdense plasma with the ultra-high intensity femtosecond laser pulses.

  15. Experimental Study of SO2 Removal by Pulsed DBD Along with the Application of Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    RONG Ming-zhe; LIU Ding-xin; WANG Xiao-hua; WANG Jun-hua

    2007-01-01

    Dielectric barrier discharge (DBD) for SO2 removal from indoor air is investigated.In order to improve the removal efficiency,two novel methods are combined in this paper,namely by applying a pulsed driving voltage with nanosecond rising time and applying a magnetic field.For SO2 removal efficiency,different matches of electric field and magnetic field are discussed.And nanosecond rising edge pulsed power supply and microsecond rising edge pulsed power supply are compared.It can be concluded that a pulsed DBD with nanosecond rising edge should be adopted,and electrical field and magnetic field should be applied in an appropriate match.

  16. Investigation on stresses of superconductors under pulsed magnetic fields based on multiphysics model

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiaobin, E-mail: yangxb@lzu.edu.cn; Li, Xiuhong; He, Yafeng; Wang, Xiaojun; Xu, Bo

    2017-04-15

    Highlights: • The differential equation including temperature and magnetic field was derived for a long cylindrical superconductor. • Thermal stress and electromagnetic stress were studied at the same time under pulse field magnetizing. • The distributions of the magnetic field, the temperature and stresses are studied and compared for two pulse fields of the different duration. • The Role thermal stress and electromagnetic stress play in the process of pulse field magnetizing is discussed. - Abstract: A multiphysics model for the numerical computation of stresses, trapped field and temperature distribution of a infinite long superconducting cylinder is proposed, based on which the stresses, including the thermal stresses and mechanical stresses due to Lorentz force, and trapped fields in the superconductor subjected to pulsed magnetic fields are analyzed. By comparing the results under pulsed magnetic fields with different pulse durations, it is found that the both the mechanical stress due to the electromagnetic force and the thermal stress due to temperature gradient contribute to the total stress level in the superconductor. For pulsed magnetic field with short durations, the thermal stress is the dominant contribution to the total stress, because the heat generated by AC-loss builds up significant temperature gradient in such short durations. However, for a pulsed field with a long duration the gradient of temperature and flux, as well as the maximal tensile stress, are much smaller. And the results of this paper is meaningful for the design and manufacture of superconducting permanent magnets.

  17. General planar transverse domain walls realized by optimized transverse magnetic field pulses in magnetic biaxial nanowires

    Science.gov (United States)

    Li, Mei; Wang, Jianbo; Lu, Jie

    2017-02-01

    The statics and field-driven dynamics of transverse domain walls (TDWs) in magnetic nanowires (NWs) have attracted continuous interests because of their theoretical significance and application potential in future magnetic logic and memory devices. Recent results demonstrate that uniform transverse magnetic fields (TMFs) can greatly enhance the wall velocity, meantime leave a twisting in the TDW azimuthal distribution. For application in high-density NW devices, it is preferable to erase the twisting so as to minimize magnetization frustrations. Here we report the realization of a completely planar TDW with arbitrary tilting attitude in a magnetic biaxial NW under a TMF pulse with fixed strength and well-designed orientation profile. We smooth any twisting in the TDW azimuthal plane thus completely decouple the polar and azimuthal degrees of freedom. The analytical differential equation describing the polar angle distribution is derived and the resulting solution is not the Walker-ansatz form. With this TMF pulse comoving, the field-driven dynamics of the planar TDW is investigated with the help of the asymptotic expansion method. It turns out the comoving TMF pulse increases the wall velocity under the same axial driving field. These results will help to design a series of modern magnetic devices based on planar TDWs.

  18. Research on Nanosecond Pulse Corona Discharge with Cross Magnetic Field Applied

    Institute of Scientific and Technical Information of China (English)

    HE Zheng-hao; YU Fu-sheng; HU Feng; YUAN Yun; GUO Li-na; LI Jin

    2007-01-01

    An application of magnetic field to the nanosecond pulse corona discharge is investigated.A cylinder reactor with different corona electodes is set up for experimental study.A manetic field with its direction perpendicular to the corona discharge is applied.Different discharge images are taken under single nanosecond pulse with a high sensitive UV-visible light imagine recorder.Experimental results show that with a cross magnetic field the nanosecond out the magnetic field. The results may lead to a possibility to apply a cross magnetic field on nanosecond pulse corona discharge for getting higher desulfurization effciency.

  19. Simultaneous measurement of magnetization and magnetostriction in 50 T pulsed high magnetic fields.

    Science.gov (United States)

    Doerr, M; Lorenz, W; Neupert, T; Loewenhaupt, M; Kozlova, N V; Freudenberger, J; Bartkowiak, M; Kampert, E; Rotter, M

    2008-06-01

    To simultaneously perform magnetization and magnetostriction measurements in high magnetic fields, a miniaturized device was developed that combines an inductive magnetometer with a capacitive dilatometer and, therefore, it is called "dilamagmeter." This combination of magnetic and magnetoelastic investigations is a new step to a complex understanding of solid state properties. The whole system can be mounted in a 12 mm clear bore of any cryostat usually used in nondestructive pulsed high field magnets. The sensitivity of both methods is about 10(-5) A m(2) for magnetization and 10(-5) relative changes in length for striction measurements. Measurements on a GdSi single crystal, which are corrected by the background signal of the experimental setup, agree well with the results of steady field experiments. All test measurements, which are up until now performed in the temperature range of 4-100 K, confirm the perfect usability and high stability in pulsed fields up to 50 T with a pulse duration of 10 ms.

  20. Analysis of Graphite Morphology of Gray Cast Iron in Pulse Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    LI Qiu-shu; LIU Li-qiang; ZHAI Qi-jie

    2005-01-01

    By self-made pulse electrical source and strong magnetic field solidification tester,the effect of strong pulse magnetic field on graphite morphology and solidification structure of gray cast iron was studied.The results show that the structure is remarkably refined after treated by pulse magnetic field,and the width of graphite flakes is decreased while the length is increased after a slight decrease.The solidification temperature and eutectic temperature are increased and the undercooling degree of eutectic transformation is decreased by magnetic field.

  1. Pulsed field magnetization strategies and the field poles composition in a bulk-type superconducting motor

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhen, E-mail: zhen.huang@sjtu.edu.cn [Academy of Information Technology and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China); Ruiz, H.S., E-mail: dr.harold.ruiz@le.ac.uk [Department of Engineering, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Coombs, T.A., E-mail: tac1000@cam.ac.uk [Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA (United Kingdom)

    2017-03-15

    Highlights: • Different compositions of the magnetic poles have been obtained depending on the relative orientation of the magnetizing coil and the surfaces of the columns of bulks that conform a magnetic pole. • Two bidimensional models accounting for the electromagnetic response of the top and lateral cross sections of three columns of HTS bulks subjected to multiple pulsed magnetic fields have been created. • An extended PFM strategy has been proposed by considering the magnetization of at least three successive columns of HTS bulks per pole. In the extended PFM strategy the area of each one of the poles can be seen increased by a factor of 200%-400% - Abstract: High temperature superconducting (HTS) bulks offer the potential of trapping and maintaining much higher magnetic loading level compared with the conventional permanent magnets used in rotary machines, although the effective magnetization of multiple HTS bulks with different relative orientations over the surface of cylindrical rotors creates new challenges. In this paper, we present the design and numerical validation of the Pulse Field Magnetization (PFM) strategy considered for the magnetization of the four-pole synchronous fully superconducting motor developed at the University of Cambridge. In a first instance, singular columns of up to five HTS bulks aligned over the height of the rotor were subjected to up to three magnetic pulses of 1.5 T peak, and the experimental results have been simulated by considering the electrical and thermal properties of the system in a 2D approach. The entire active surface of the rotor is covered by HTS bulks of approximately the same dimensions, resulting in an uneven distribution of pole areas with at least one of the poles formed by up to 3 columns of magnetized bulks, with relatively the same peaks of trapped magnetic field. Thus, in order to effectively use the entire area of the superconducting rotor, multiple pulsed fields per column have been applied

  2. Experimental studies of axial magnetic fields generated in ultrashort-pulse laser-plasma interaction

    Institute of Scientific and Technical Information of China (English)

    李玉同; 张杰; 陈黎明; 赵理曾; 夏江帆; 魏志义; 江文勉

    2000-01-01

    The quasistatic axial magnetic fields in plasmas produced by ultrashort laser pulses were measured by measuring the Faraday rotation angle of the backscattered emission. The spatial distribution of the axial magnetic field was obtained with a peak value as high as 170 Tesla. Theory suggests that the axial magnetic field is generated by dynamo effect in laser-plasma interaction.

  3. Metamagnetic transitions of DyAg in pulsed high magnetic field

    Science.gov (United States)

    Yamagishi, A.; Yonenobu, K.; Kondo, O.; Morin, P.; Date, M.

    1990-12-01

    Metamagnetic transitions of a single crystal DyAg are investigated by using pulsed magnetic fields up to 410 kOe. Four step-magnetizations are found with the field along the [111] direction. These transitions are well understood by introducing a new model that the quadrupole order is quenched under high magnetic field.

  4. Metamagnetic transitions of DyAg in pulsed high magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, A.; Yonenobu, K.; Kondo, O.; Date, M. (Research Center for Extreme Materials, Osaka Univ. (Japan)); Morin, P. (Lab. Louis Neel, CNRS, 38 - Grenoble (France))

    1990-12-01

    Metamagnetic transitions of a single crystal DyAg are investigated by using pulsed magnetic fields up to 410 kOe. Four step-magnetizations are found with the field along the (111) direction. These transitions are well understood by introducing a new model that the quadrupole order is quenched under high magnetic field. (orig.).

  5. Nuclear forward scattering of synchrotron radiation in pulsed high magnetic fields.

    Science.gov (United States)

    Strohm, C; Van der Linden, P; Rüffer, R

    2010-02-26

    We report the demonstration of nuclear forward scattering of synchrotron radiation from 57Fe in ferromagnetic alpha iron in pulsed high magnetic fields up to 30 T. The observed magnetic hyperfine field follows the calculated high field bulk magnetization within 1%, establishing the technique as a precise tool for the study of magnetic solids in very high magnetic fields. To perform these experiments in pulsed fields, we have developed a detection scheme for fully time resolved nuclear forward scattering applicable to other pump probe experiments.

  6. Generation of flat-top pulsed magnetic fields with feedback control approach

    CERN Document Server

    Kohama, Yoshimitsu

    2015-01-01

    We describe the construction of a simple, compact, and cost-effective feedback system that produces flat-top field profiles in pulsed magnetic fields. This system is designed for use in conjunction with a typical capacitor-bank driven pulsed magnet, and was tested using a 60-T pulsed magnet. With the developed feedback controller, we have demonstrated flat-top magnetic fields as high as 60.64 T with an excellent field stability of +-0.005 T. The result indicates that the flat-top pulsed magnetic field produced features high field stability and an accessible field strength. These features make this system useful for improving the resolution of data with signal averaging.

  7. Simulation and experiments of Stacks of High Temperature Superconducting Coated Conductors Magnetized by Pulsed Field Magnetization with Multi-Pulse Technique

    CERN Document Server

    Zou, Shengnan; Baskys, A; Patel, A; Grilli, Francesco; Glowacki, B A

    2016-01-01

    High temperature superconducting (HTS) bulks or stacks of coated conductors (CCs) can be magnetized to become trapped field magnets (TFMs). The magnetic fields of such TFMs can break the limitation of conventional magnets (<2 T), so they show potential for improving the performance of many electrical applications that use permanent magnets like rotating machines. Towards practical or commercial use of TFMs, effective in situ magnetization is one of the key issues. The pulsed field magnetization (PFM) is among the most promising magnetization methods in virtue of its compactness, mobility and low cost. However, due to the heat generation during the magnetization, the trapped field and flux acquired by PFM usually cannot achieve the full potential of a sample (acquired by the field cooling or zero field cooling method). The multi-pulse technique was found to effectively improve the trapped field by PFM in practice. In this work, a systematic study on the PFM with successive pulses is presented. A 2D electrom...

  8. Manipulating antiferromagnets with magnetic fields: Ratchet motion of multiple domain walls induced by asymmetric field pulses

    Science.gov (United States)

    Gomonay, O.; Kläui, M.; Sinova, J.

    2016-10-01

    Future applications of antiferromagnets (AFs) in many spintronics devices rely on the precise manipulation of domain walls. The conventional approach using static magnetic fields is inefficient due to the low susceptibility of AFs. Recently proposed electrical manipulation with spin-orbit torques is restricted to metals with a specific crystal structure. Here, we propose an alternative, broadly applicable approach: using asymmetric magnetic field pulses to induce controlled ratchet motion of AF domain walls. The efficiency of this approach is based on three peculiarities of AF dynamics. First, a time-dependent magnetic field couples with an AF order parameter stronger than a static magnetic field, which leads to higher mobility of the domain walls. Second, the rate of change of the magnetic field couples with the spatial variation of the AF order parameter inside the domain, and this enables a synchronous motion of multiple domain walls with the same structure. Third, tailored asymmetric field pulses in combination with static friction can prevent backward motion of domain walls and thus lead to the desired controlled ratchet effect. The proposed use of an external field, rather than internal spin-orbit torques, avoids any restrictions on size, conductivity, and crystal structure of the AF material. We believe that our approach paves a way for the development of AF-based devices based on the controlled motion of AF domain walls.

  9. Determining the exchange parameters of spin-1 metal-organic molecular magnets in pulsed magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Mcdonald, Ross D [Los Alamos National Laboratory; Singleton, John [Los Alamos National Laboratory; Lancaster, Tom [OXFORD UNIV.; Goddard, Paul [OXFORD UNIV.; Manson, Jamie [EASTERN WASHINGTON UNIV.

    2011-01-14

    We nave measured the high-field magnetization of a number of Ni-based metal-organic molecular magnets. These materials are self-assembly coordination polymers formed from transition metal ions and organic ligands. The chemistry of the compounds is versatile allowing many structures with different magnetic properties to be formed. These studies follow on from previous measurements of the Cu-based analogues in which we showed it was possible to extract the exchange parameters of low-dimensional magnets using pulsed magnetic fields. In our recent experiments we have investigated the compound (Ni(HF{sub 2})(pyz){sub 2})PF{sub 6}, where pyz = pyrazine, and the Ni-ions are linked in a quasi-two-dimensional (Q2D) square lattice via the pyrazine molecules, with the layers held together by HF{sub 2} ligands. We also investigated Ni(NCS){sub 2}(pyzdo){sub 2}, where pyzdo = pyrazine dioxide. The samples are grown at Eastern Washington University using techniques described elsewhere. Measurements are performed at the pulsed magnetic field laboratory in Los Alamos. The magnetization of powdered samples is determined using a compensated coil magnetometer in a 65 T short pulse magnet. Temperatures as low as 500 mK are achievable using a {sup 3}He cryostat. The main figure shows the magnetization of the spin-1 [Ni(HF{sub 2})(pyz){sub 2}]PF{sub 6} compound at 1.43 K. The magnetization rises slowly at first, achieving a rounded saturation whose midpoint is around 19 T. A small anomaly is also seen in the susceptibility at low fields ({approx}3 T), which might be attributed to a spin-flop transition. In contrast, the spin-1/2 [Cu(HF{sub 2})(pyz){sub 2}]PF{sub 6} measured previously has a saturation magnetization of 35.5 T and a strongly concave form of M(B) below this field. This latter compound was shown to be a good example of a Q2D Heisenberg antiferromagnet with the strong exchange coupling (J{sub 2D} = 12.4 K, J{sub {perpendicular}}/J{sub 2D} {approx} 10{sup -2}) directed along

  10. Low-noise pulsed current source for magnetic-field measurements of magnets for accelerators

    Science.gov (United States)

    Omelyanenko, M. M.; Borisov, V. V.; Donyagin, A. M.; Khodzhibagiyan, H. G.; Kostromin, S. A.; Makarov, A. A.; Shemchuk, A. V.

    2017-01-01

    The schematic diagram, design, and technical characteristics of the pulsed current source developed and produced for the magnetic-field measurement system of superconducting magnets for accelerators are described. The current source is based on the current regulator with pass transistor bank in the linear mode. Output current pulses (0-100 A) are produced by utilizing the energy of the preliminarily charged capacitor bank (5-40 V), which is additionally charged between pulses. The output current does not have the mains frequency and harmonics ripple. The relative noise level is less than-100 dB (or 10-5) of RMS value (it is defined as the ratio of output RMS noise current to a maximal output current of 100 A within the operating bandwidth, expressed in dB). The work was performed at the Veksler and Baldin Laboratory of High Energy Physics, Joint Institute for Nuclear Research (JINR).

  11. Switching of chiral magnetic skyrmions by picosecond magnetic field pulses via transient topological states

    Science.gov (United States)

    Heo, Changhoon; Kiselev, Nikolai S.; Nandy, Ashis Kumar; Blügel, Stefan; Rasing, Theo

    2016-06-01

    Magnetic chiral skyrmions are vortex like spin structures that appear as stable or meta-stable states in magnetic materials due to the interplay between the symmetric and antisymmetric exchange interactions, applied magnetic field and/or uniaxial anisotropy. Their small size and internal stability make them prospective objects for data storage but for this, the controlled switching between skyrmion states of opposite polarity and topological charge is essential. Here we present a study of magnetic skyrmion switching by an applied magnetic field pulse based on a discrete model of classical spins and atomistic spin dynamics. We found a finite range of coupling parameters corresponding to the coexistence of two degenerate isolated skyrmions characterized by mutually inverted spin structures with opposite polarity and topological charge. We demonstrate how for a wide range of material parameters a short inclined magnetic field pulse can initiate the reliable switching between these states at GHz rates. Detailed analysis of the switching mechanism revealed the complex path of the system accompanied with the excitation of a chiral-achiral meron pair and the formation of an achiral skyrmion.

  12. Effect of pulse magnetic field on solidification structure and properties of pure copper

    Institute of Scientific and Technical Information of China (English)

    LIAO Xi-liang; GONG Yong-yong; LI Ren-xing; CHEN Wen-jie; ZHAI Qi-jie

    2007-01-01

    The application of pulse magnetic field to metal solidification is an advanced technique which can remarkably refine solidification structure. In this paper, the effect of pulse magnetic field on solidification structure,mechanical properties and conductivity of pure copper was experimentally investigated. The results showed that the solidification structure transformed from coarse columnar crystal to fine globular crystal with increasing pulse voltage.Increasing pulse voltage also improved the tensile strength. However, with the increase of pulse voltage, the elongation and electrical resistivity firstly decreased, then increased when the pulse voltage beyond a critical value. Moreover,in some conditions, pulse magnetic field can simultaneously improve the conductivity and mechanical property of pure copper.

  13. Internal Magnetic Field, Temperature and Density Measurements on Magnetized HED plasmas using Pulsed Polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Roger J. [Univ. of Washington, Seattle, WA (United States)

    2016-10-20

    The goals were to collaborate with the MSX project and make the MSX platform reliable with a performance where pulsed polarimetry would be capable of adding a useful measurement and then to achieve a first measurement using pulsed polarimetry. The MSX platform (outside of laser blow off plasmas adjacent to magnetic fields which are low beta) is the only device that can generate high beta magnetized collisionless supercritical shocks, and with a large spatial size of ~10 cm. Creating shocks at high Mach numbers and investigating the dynamics of the shocks was the main goal of the project. The MSX shocks scale to astrophysical magnetized shocks and potentially throw light on the generation of highly energetic particles via a mechanism like the Fermi process.

  14. The impacts of magnetic field on repetitive nanosecond pulsed dielectric barrier discharge in air

    Science.gov (United States)

    Liu, Yidi; Qi, Haicheng; Fan, Zhihui; Yan, Huijie; Ren, ChunSheng

    2016-11-01

    In this paper, the impacts of the parallel magnetic field on the repetitive nanosecond pulsed dielectric barrier discharge (DBD) are experimentally investigated by optical and electrical measurements. The DBD is generated between two parallel-plate electrodes in the ambient air with the stationary magnetic field on the order of 1 T. The experimental results show that additional microdischarge channels are generated and the photocurrent intensity of the plasma is increased by the magnetic field. The microdischarge channels develop along the magnetic field lines and the diffuse background emission of the discharge is stronger in the DBD with the magnetic field. As the pulse repetition frequency decreases from 1200 Hz to 100 Hz, only the photocurrent intensity of the third discharge that occurred at about 500 ns is noticeably increased by the additional magnetic field. It is believed that the enhancement of the memory effect and the confinement of the magnetic field on electrons are the main reasons.

  15. Study on technology of high-frequency pulsed magnetic field strength measurement.

    Science.gov (United States)

    Chen, Yi-Mei; Liu, Zhi-Peng; Yin, Tao

    2012-01-01

    High-frequency transient weak magnetic field is always involved in researches about biomedical engineering field while common magnetic-field sensors cannot work properly at frequencies as high as MHz. To measure the value of MHz-level weak pulsed magnetic-field strength accurately, this paper designs a measurement and calibration method for pulsed magnetic-field. In this paper, a device made of Nonferromagnetic material was independently designed and applied to pulsed magnetic field measurement. It held an accurately relative position between the magnetic field generating coil and the detecting coil. By applying a sinusoidal pulse to the generator, collecting the induced electromotive force of the detector, the final magnetic field strength was worked out through algorithms written in Matlab according to Faraday's Law. Experiments were carried out for measurement and calibration. Experiments showed that, under good stability and consistency, accurate measurement of magnetic-field strength of a sinepulse magnetic-field can be achieved, with frequency at 0.5, 1, 1.5 MHz and strength level at micro-Tesla. Calibration results carried out a measuring relative error about 2.5%.

  16. A portable magnetic field of >3 T generated by the flux jump assisted, pulsed field magnetization of bulk superconductors

    Science.gov (United States)

    Zhou, Difan; Ainslie, Mark D.; Shi, Yunhua; Dennis, Anthony R.; Huang, Kaiyuan; Hull, John R.; Cardwell, David A.; Durrell, John H.

    2017-02-01

    A trapped magnetic field of greater than 3 T has been achieved in a single grain GdBa2Cu3O7-δ (GdBaCuO) bulk superconductor of diameter 30 mm by employing pulsed field magnetization. The magnet system is portable and operates at temperatures between 50 K and 60 K. Flux jump behaviour was observed consistently during magnetization when the applied pulsed field, Ba, exceeded a critical value (e.g., 3.78 T at 60 K). A sharp dBa/dt is essential to this phenomenon. This flux jump behaviour enables the magnetic flux to penetrate fully to the centre of the bulk superconductor, resulting in full magnetization of the sample without requiring an applied field as large as that predicted by the Bean model. We show that this flux jump behaviour can occur over a wide range of fields and temperatures, and that it can be exploited in a practical quasi-permanent magnet system.

  17. Decoupling of excitation and receive coils in pulsed magnetic resonance using sinusoidal magnetic field modulation

    Science.gov (United States)

    Tseytlin, Mark; Epel, Boris; Sundramoorthy, Subramanian; Tipikin, Dmitriy; Halpern, Howard J.

    2016-11-01

    In pulsed magnetic resonance, the excitation power is many orders of magnitude larger than that induced by the spin system in the receiving coil or resonator. The receiver must be protected during and immediately after the excitation pulse to allow for the energy stored in the resonator to dissipate to a safe level. The time during which the signal is not detected, the instrumental dead-time, can be shortened by using magnetically decoupled excitation and receive coils. Such coils are oriented, with respect to each other, in a way that minimizes the total magnetic flux produced by one coil in the other. We suggest that magnetically decoupled coils can be isolated to a larger degree by tuning them to separate frequencies. Spins are excited at one frequency, and the echo signal is detected at another. Sinusoidal magnetic field modulation that rapidly changes the Larmor frequency of the spins between the excitation and detection events is used to ensure the resonance conditions for both coils. In this study, the relaxation times of trityl-CD3 were measured in a field-modulated pulsed EPR experiment and compared to results obtained using a standard spin echo method. The excitation and receive coils were tuned to 245 and 256.7 MHz, respectively. Using an available rapid-scan, cross-loop EPR resonator, we demonstrated an isolation improvement of approximately 20-30 dB due to frequency decoupling. Theoretical analysis, numerical simulations, and proof-of-concept experiments demonstrated that substantial excitation-detection decoupling can be achieved. A pulsed L-band system, including a small volume bi-modal resonator equipped with modulation coils, was constructed to demonstrate fivefold dead-time reduction in comparison with the standard EPR experiment. This was achieved by detuning of the excitation and receive coils by 26 MHz and using sinusoidal modulation at 480 kHz.

  18. Simulation and experiments of stacks of high temperature superconducting coated conductors magnetized by pulsed field magnetization with multi-pulse technique

    Science.gov (United States)

    Zou, Shengnan; Zermeño, Víctor M. R.; Baskys, A.; Patel, A.; Grilli, Francesco; Glowacki, B. A.

    2017-01-01

    High temperature superconducting bulks or stacks of coated conductors (CCs) can be magnetized to become trapped field magnets (TFMs). The magnetic fields of such TFMs can break the limitation of conventional magnets (low cost. However, due to the heat generation during the magnetization, the trapped field and flux acquired by PFM usually cannot achieve the full potential of a sample (acquired by the field cooling or zero field cooling method). The multi-pulse technique was found to effectively improve the trapped field by PFM in practice. In this work, a systematic study on the PFM with successive pulses is presented. A 2D electromagnetic-thermal coupled model with comprehensive temperature dependent parameters is used to simulate a stack of CCs magnetized by successive magnetic pulses. An overall picture is built to show how the trapped field and flux evolve with different pulse sequences and the evolution patterns are analyzed. Based on the discussion, an operable magnetization strategy of PFM with successive pulses is suggested to provide more trapped field and flux. Finally, experimental results of a stack of CCs magnetized by typical pulse sequences are presented for demonstration.

  19. Cu-Ag alloy Bitter type magnet for repeating pulsed field

    Energy Technology Data Exchange (ETDEWEB)

    Motokawa, M.; Nojiri, H.; Mitsudo, S. [Tohoku Univ., Sendai (Japan). Inst. for Materials Research; Arai, M.; Ubukata, K.; Fujita, M.; Arakawa, T.; Inamura, Y. [Kobe Univ. (Japan). Dept. of Physics

    1996-07-01

    Cu-Ag alloy is used for the repeating pulsed field magnets. It is found that fields up to 22 T or more will be available for this purpose instead of 16 T which is obtained with normal copper magnet used at present. This result is a big advantage for neutron diffraction experiments.

  20. A high-field pulsed magnet system for x-ray scattering studies in Voigt geometry

    CERN Document Server

    Islam, Zahirul; Ruff, Jacob P C; Das, Ritesh K; Trakhtenberg, Emil; Nojiri, Hiroyuki; Narumi, Yasuo; Canfield, Paul C

    2011-01-01

    We present a new pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies in Voigt geometry. The apparatus consists of a large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic fields up to ~30 T with a minimum of ~6 ms in total duration are generated by discharging a 40 kJ capacitor bank into the magnet coil. The unique characteristic of this instrument is the preservation of maximum scattering angle (~23.6 deg.) through the magnet bore by virtue of a novel double-funnel insert. This instrument would facilitate x-ray diffraction and spectroscopic studies that are impractical, if not impossible, to perform using conventional split-pair magnets and offers a practical solution for preserving optical access in future higher-field pulsed magnets.

  1. Development of a 50-T pulsed magnetic field facility by using an 1.5-MJ capacitor bank

    Science.gov (United States)

    Shin, Y. H.; Kim, Yongmin

    2015-09-01

    Because DC magnets consume a huge amount of electricity (resistive DC magnet) or liquid helium (superconducting magnet), a capacitor-bank-driven pulsed magnet is known to be a cost-effective way of generating high magnetic fields. This type of pulsed magnet is normally operated at liquid nitrogen temperature and consumes little electric power to generate over 50 tesla (T) during a short transient time of less than 50 millisecond (ms). With modern fast data acquisition systems, almost all kinds of physical quantities, such as photoluminescence, magnetization or resistance can be measured during a short magnetic field pulse. We report a recently home-built capacitor-bankdriven pulsed magnetic field facility, in which a capacitor bank of 1.5-MJ maximum stored energy is utilized to generate pulsed magnetic fields up to 50 T with transient pulse time of 22 ms.

  2. Modulated heat pulse propagation and partial transport barriers in chaotic magnetic fields

    CERN Document Server

    del-Castillo-Negrete, D

    2016-01-01

    Direct numerical simulations of the time dependent parallel heat transport equation modeling heat pulses driven by power modulation in 3-dimensional chaotic magnetic fields are presented. The numerical method is based on the Fourier formulation of a Lagrangian-Green's function method that provides an accurate and efficient technique for the solution of the parallel heat transport equation in the presence of harmonic power modulation. The numerical results presented provide conclusive evidence that even in the absence of magnetic flux surfaces, chaotic magnetic field configurations with intermediate levels of stochasticity exhibit transport barriers to modulated heat pulse propagation. In particular, high-order islands and remnants of destroyed flux surfaces (Cantori) act as partial barriers that slow down or even stop the propagation of heat waves at places where the magnetic field connection length exhibits a strong gradient. Results on modulated heat pulse propagation in fully stochastic fields and across m...

  3. 25 Tesla pulsed-high-magnetic-field system for soft X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, M., E-mail: mhaya@imr.tohoku.ac.jp [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Narumi, Y.; Nojiri, H. [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Nakamura, T.; Hirono, T.; Kinoshita, T. [JASRI/SPring-8, Sayo, Hyogo 679-5198 (Japan); Kodama, K. [Department of Mechanical Engineering, Nara National College of Technology, Nara 639-1080 (Japan); Kindo, K. [Institute for Solid State Physics, University of Tokyo, Kashiwa 277-8581 (Japan)

    2011-04-15

    Research highlights: {yields} We have developed a 25 T pulsed magnetic field system for soft X-ray MCD. {yields} The new capacitor bank can generate a field in the bipolar mode. {yields} We measured the Soft X-ray MCD of paramagnetic Gd{sub 2}O{sub 3} up to 25 T. - Abstract: We have developed a 25 T pulsed high magnetic field system for soft X-ray Magnetic Circular Dichroism: XMCD. The ultra-high vacuum chamber with a pulse magnet coil is installed. By using a newly developed bipolar capacitor bank, the XMCD of paramagnetic Gd{sub 2}O{sub 3} at the M{sub 5} and the M{sub 4} edges was clearly observed at low temperatures. The present system is capable of measuring XMCD of field induced moments in various compounds including paramagnets and antiferromagnets.

  4. Transition-Selective Pulses in Zero-Field Nuclear Magnetic Resonance.

    Science.gov (United States)

    Sjolander, Tobias F; Tayler, Michael C D; King, Jonathan P; Budker, Dmitry; Pines, Alexander

    2016-06-30

    We use low-amplitude, ultralow frequency pulses to drive nuclear spin transitions in zero and ultralow magnetic fields. In analogy to high-field NMR, a range of sophisticated experiments becomes available as these allow narrow-band excitation. As a first demonstration, pulses with excitation bandwidths 0.5-5 Hz are used for population redistribution, selective excitation, and coherence filtration. These methods are helpful when interpreting zero- and ultralow-field NMR spectra that contain a large number of transitions.

  5. Quantum ring states in magnetic field and delayed half-cycle pulses

    Indian Academy of Sciences (India)

    KRITI BATRA; HIRA JOSHI; VINOD PRASAD

    2016-08-01

    The present work is dedicated to the time evolution of excitation of a quantum ring in external electric and magnetic fields. Such a ring of mesoscopic dimensions in an external magnetic field is known to exhibit a wide variety of interesting physical phenomena. We have studied the dynamics of the single electron quantum ring in the presence of a static magnetic field and a combination of delayed half-cycle pulse pair. Detailed calculations have been worked out and the impact on dynamics by variation in the ring radius, intensity of external electric field, delay between the two pulses, and variation in magnetic field have been reported. A total of 19 states have been taken and the population transfer in the single electron quantum ring is studied by solving the time-dependent Schrödinger equation (TDSE), using the efficient fourth-order Runge--Kutta method. Many interesting features have been observed in the transition probabilities with the variation of magnetic field, delay between pulses and ring dimensions. A very important aspect of the present work is the persistent current generation in a quantum ring in the presence of external magnetic flux and its periodic variation with the magnetic flux, ring dimensions and pulse delay.

  6. Tailored RF pulse optimization for magnetization inversion at ultra high field

    CERN Document Server

    Hurley, Aaron C; Li, Bai; Aickelin, Uwe; Coxon, Ron; Glover, Paul; Gowland, Penny A

    2010-01-01

    The radiofrequency (RF) transmit field is severely inhomogeneous at ultrahigh field due to both RF penetration and RF coil design issues. This particularly impairs image quality for sequences that use inversion pulses such as magnetization prepared rapid acquisition gradient echo and limits the use of quantitative arterial spin labeling sequences such as flow-attenuated inversion recovery. Here we have used a search algorithm to produce inversion pulses tailored to take into account the heterogeneity of the RF transmit field at 7 T. This created a slice selective inversion pulse that worked well (good slice profile and uniform inversion) over the range of RF amplitudes typically obtained in the head at 7 T while still maintaining an experimentally achievable pulse length and pulse amplitude in the brain at 7 T. The pulses used were based on the frequency offset correction inversion technique, as well as time dilation of functions, but the RF amplitude, frequency sweep, and gradient functions were all generate...

  7. Switching field dependence on heating pulse duration in thermally assisted magnetic random access memories

    Energy Technology Data Exchange (ETDEWEB)

    Papusoi, C. [Spintec, URA 2512 CEA/CNRS, 17 rue des Martyrs, 38054 Grenoble (France)], E-mail: cristian_papusoi@yahoo.com; Conraux, Y.; Prejbeanu, I.L. [Crocus Technology, 5 Robert Schumann, BP 1510, 38025 Grenoble (France); Sousa, R.; Dieny, B. [Spintec, URA 2512 CEA/CNRS, 17 rue des Martyrs, 38054 Grenoble (France)

    2009-08-15

    The minimum applied field H{sub SW} required to reverse the magnetic moment of the ferromagnetic/antiferromagnetic storage layer of a thermally assisted magnetic random access memory (TA-MRAM) device during the application of a heating electric pulse is investigated as a function of pulse power P{sub HP} and duration {delta}. For the same power of the heating pulse P{sub HP} (or, equivalently, for the same temperature of the storage layer), H{sub SW} increases with decreasing heating time {delta}. This behavior is consistently interpreted by a thermally activated propagating domain-wall switching model, corroborated by a real-time study of switching. The increase of H{sub SW} with decreasing pulse width introduces a constraint for the minimum power consumption of a TA-MRAM where writing combines heating and magnetic field application.

  8. Investigation on stresses of superconductors under pulsed magnetic fields based on multiphysics model

    Science.gov (United States)

    Yang, Xiaobin; Li, Xiuhong; He, Yafeng; Wang, Xiaojun; Xu, Bo

    2017-04-01

    A multiphysics model for the numerical computation of stresses, trapped field and temperature distribution of a infinite long superconducting cylinder is proposed, based on which the stresses, including the thermal stresses and mechanical stresses due to Lorentz force, and trapped fields in the superconductor subjected to pulsed magnetic fields are analyzed. By comparing the results under pulsed magnetic fields with different pulse durations, it is found that the both the mechanical stress due to the electromagnetic force and the thermal stress due to temperature gradient contribute to the total stress level in the superconductor. For pulsed magnetic field with short durations, the thermal stress is the dominant contribution to the total stress, because the heat generated by AC-loss builds up significant temperature gradient in such short durations. However, for a pulsed field with a long duration the gradient of temperature and flux, as well as the maximal tensile stress, are much smaller. And the results of this paper is meaningful for the design and manufacture of superconducting permanent magnets.

  9. Enhanced trapped field performance of bulk high-temperature superconductors using split coil, pulsed field magnetization with an iron yoke

    Science.gov (United States)

    Ainslie, M. D.; Fujishiro, H.; Mochizuki, H.; Takahashi, K.; Shi, Y.-H.; Namburi, D. K.; Zou, J.; Zhou, D.; Dennis, A. R.; Cardwell, D. A.

    2016-07-01

    Investigating and predicting the magnetization of bulk superconducting materials and developing practical magnetizing techniques is crucial to using them as trapped field magnets in engineering applications. The pulsed field magnetization (PFM) technique is considered to be a compact, mobile and relative inexpensive way to magnetize bulk samples, requiring shorter magnetization times (on the order of milliseconds) and a smaller and less complicated magnetization fixture; however, the trapped field produced by PFM is generally much smaller than that of slower zero field cooling or field cooling techniques, particularly at lower operating temperatures. In this paper, the PFM of two, standard Ag-containing Gd-Ba-Cu-O samples is carried out using two types of magnetizing coils: (1) a solenoid coil, and (2) a split coil, both of which make use of an iron yoke to enhance the trapped magnetic field. It is shown that a significantly higher trapped field can be achieved using a split coil with an iron yoke, and in order to explain these how this arrangement works in detail, numerical simulations using a 2D axisymmetric finite element method based on the H -formulation are carried to qualitatively reproduce and analyze the magnetization process from both electromagnetic and thermal points of view. It is observed that after the pulse peak significantly less flux exits the bulk when the iron core is present, resulting in a higher peak trapped field, as well as more overall trapped flux, after the magnetization process is complete. The results have important implications for practical applications of bulk superconductors as such a split coil arrangement with an iron yoke could be incorporated into the design of a portable, high magnetic field source/magnet to enhance the available magnetic field or in an axial gap-type bulk superconducting electric machine, where iron can be incorporated into the stator windings to (1) improve the trapped field from the magnetization process

  10. Analytical solution for the diffusion of a capacitor discharge generated magnetic field pulse in a conductor

    Directory of Open Access Journals (Sweden)

    Ilmārs Grants

    2016-06-01

    Full Text Available Powerful forces arise when a pulse of a magnetic field in the order of a few tesla diffuses into a conductor. Such pulses are used in electromagnetic forming, impact welding of dissimilar materials and grain refinement of solidifying alloys. Strong magnetic field pulses are generated by the discharge current of a capacitor bank. We consider analytically the penetration of such pulse into a conducting half-space. Besides the exact solution we obtain two simple self-similar approximate solutions for two sequential stages of the initial transient. Furthermore, a general solution is provided for the external field given as a power series of time. Each term of this solution represents a self-similar function for which we obtain an explicit expression. The validity range of various approximate analytical solutions is evaluated by comparison to the exact solution.

  11. Analytical solution for the diffusion of a capacitor discharge generated magnetic field pulse in a conductor

    Science.gov (United States)

    Grants, Ilmārs; Bojarevičs, Andris; Gerbeth, Gunter

    2016-06-01

    Powerful forces arise when a pulse of a magnetic field in the order of a few tesla diffuses into a conductor. Such pulses are used in electromagnetic forming, impact welding of dissimilar materials and grain refinement of solidifying alloys. Strong magnetic field pulses are generated by the discharge current of a capacitor bank. We consider analytically the penetration of such pulse into a conducting half-space. Besides the exact solution we obtain two simple self-similar approximate solutions for two sequential stages of the initial transient. Furthermore, a general solution is provided for the external field given as a power series of time. Each term of this solution represents a self-similar function for which we obtain an explicit expression. The validity range of various approximate analytical solutions is evaluated by comparison to the exact solution.

  12. Charge and spin current oscillations in a tunnel junction induced by magnetic field pulses

    Science.gov (United States)

    Dartora, C. A.; Nobrega, K. Z.; Cabrera, G. G.

    2016-08-01

    Usually, charge and spin transport properties in tunnel junctions are studied in the DC bias regime and/or in the adiabatic regime of time-varying magnetic fields. In this letter, the temporal dynamics of charge and spin currents in a tunnel junction induced by pulsed magnetic fields is considered. At low bias voltages, energy and momentum of the conduction electrons are nearly conserved in the tunneling process, leading to the description of the junction as a spin-1/2 fermionic system coupled to time-varying magnetic fields. Under the influence of pulsed magnetic fields, charge and spin current can flow across the tunnel junction, displaying oscillatory behavior, even in the absence of DC bias voltage. A type of spin capacitance function, in close analogy to electric capacitance, is predicted.

  13. Research on the Pulsed Magnetic Field Device for Sterilization of Fruit and Vegetable Equipment

    Directory of Open Access Journals (Sweden)

    Liu Mingdan

    2013-04-01

    Full Text Available In view of the requests of the sterilization device of the fruit and vegetable that integrate cleaning and juicing together, and combined with the electromagnetic theory and the cold sterilization technology which is in common use in modern food industry, circuits are designed for the pulsed magnetic field sterilization device of the integrated machine .This circuits chose a linear solenoid in which r= 30mm, l= 200 mm. The experiment shows that the pulsed magnetic field produced by the device can achieve a better effect in killing bacillus coli, beer yeast and staphylococcus aurous, etc. Compared with the traditional sterilization device, the bactericidal effect of the pulsed magnetic field sterilization device is more obvious so that it will be the direction of the development of food equipments. [1]  

  14. A 3He Cryostat for Scientific Measurements in Pulsed High Magnetic Fields

    Science.gov (United States)

    Wang, Shaoliang; Li, Liang; Liu, Mengyu; Zuo, Huakun; Peng, Tao

    A top loading 3He cryostat has been developed for scientific experiments with a 60 T pulsed magnetic field facility at Wuhan National High Magnetic Field Center. The cryostat consists of a 4He bath cryostat, a 3He insert and a closed circulation system for 3He gas handling. To eliminate the eddy current heating during the pulse, the tail of the 3He insert with a vacuum space at the bottom is made from fiberglass tubing coated with epoxy. The 3He bath is separated from the 4He bath with the vacuum space. The 4He bath cryostat provides cooling power to condense 3He gas by a neck tube on top of the tail. Experimental results have shown that the sample can be cooled down to 385 mK and kept cold for more than 150 second by one-shot cooling, which is sufficiently long for an experiment in a pulsed high magnetic field.

  15. Sterilization of Escherichia coli cells by the application of pulsed magnetic field

    Institute of Scientific and Technical Information of China (English)

    LI Mei; QU Jiu-hui; PENG Yong-zhen

    2004-01-01

    The inactivation of microorganisms by pulsed magnetic field was studied. It was improved that theapplication of electromagnetic pulses evidently causes a lethal effect on E. coli cells suspended in phosphate buffersolution Na2 HPO4 / NaH2 PO4 (0.334/0.867 mmol/L). Experimental results indicated that the survivability( N/N0; whereN0 and N are the number of cells survived per milliliter before and after electromagnetic pulses application,respectively) of E. coli decreased with magnetic field intensity B and treatment time t. It was also found that themedium temperatures, the frequencies of pulse f, and the initial bacterial cell concentrations have determinateinfluences in destruction of E. coli cells by the application of magnetic pulses. The application of an magneticintensity B = 160 mT at pulses frequency f = 62 kHz and treatment time t = 16 h result in a considerable destructionlevels of E. coli cells ( N/N0 = 10-4 ). Possible mechanisms involved in sterilization of the magnetic field treatmentwere discussed. In order to shorten the treatment time, many groups of parallel inductive coil were used. Thepracticability test showed that the treatment time was shortened to 4 h with the application of three groups of parallelcoil when the survivability of E. coli cells was less than 0.01%; and the power consumption was about 0.2 kWh/m3 .

  16. Use of a probing pulsed magnetic field for determining plasma parameters

    Science.gov (United States)

    Rousskikh, A. G.; Oreshkin, V. I.; Zhigalin, A. S.; Yushkov, G. Yu.

    2016-11-01

    A novel, simple, and readily usable method is proposed for measuring the electrical conductivity and temperature of a plasma. The method is based on the interaction of the test plasma with a pulsed magnetic field. The electric signals induced by the magnetic field in the circuits of two probes (miniature solenoids), one immersed in the test plasma and the other placed outside the plasma, provide data for estimating the plasma parameters. The method was verified experimentally by determining the parameters of the plasma flows generated in the cathode spots high-current pulsed vacuum arcs that were used to form cylindrical shells of bismuth Z-pinch plasma.

  17. Unipolar magnetic field pulses as transient signals prior to the 2009 Aquila earthquake shock

    CERN Document Server

    Nenovski, Petko

    2016-01-01

    Unipolar pre-seismic magnetic field pulses have been observed first by Bleier et al. (2009) and Villante et al. (2010) and Nenovski et al. (2013). In the present study a detailed analysis of the pulses is conducted looking for signatures of transient signals similar to that recorded at the 2009 Aquila earthquake main shock (Nenovski, 2015). Various magnetic field data around the Aquila earthquake provide an instrumental basis for such an analysis. In addition to fluxgate magnetometer data (already examined in previous studies), overhauser magnetometer data are involved. The result is a detection and discrimination of transient signals of diffusive form that appear prior to the earthquake main shock.

  18. Flux motion in Y-Ba-Cu-O bulk superconductors during pulse field magnetization

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, K [Department of Physics, College of Humanities and Sciences, Nihon University, 3-25-40 Sakura-Josui, Setagaya-ku, Tokyo 156-8550 (Japan); Nariki, S [Division of Material Science and Physics, Bulk Superconductor Laboratory, 1-16-25 Shibaura, Minato-ku, Tokyo 105-0023 (Japan); Sakai, N [Division of Material Science and Physics, Bulk Superconductor Laboratory, 1-16-25 Shibaura, Minato-ku, Tokyo 105-0023 (Japan); Murakami, M [Division of Material Science and Physics, Bulk Superconductor Laboratory, 1-16-25 Shibaura, Minato-ku, Tokyo 105-0023 (Japan); Hirabayasi, I [Division of Material Science and Physics, Bulk Superconductor Laboratory, 1-16-25 Shibaura, Minato-ku, Tokyo 105-0023 (Japan); Takizawa, T [Department of Physics, College of Humanities and Sciences, Nihon University, 3-25-40 Sakura-Josui, Setagaya-ku, Tokyo 156-8550 (Japan)

    2004-02-01

    We have studied the relationship between the magnetization and temperature change in Y-Ba-Cu-O bulk superconductor during pulse field magnetization (PFM). The flux motion was monitored using both Hall sensors and pick-up coils that are placed on a surface of a Y-Ba-Cu-O disc having dimensions of 15 mm in diameter and 0.95 mm in thickness. The peak value of the field was varied from 0.2 to 0.8 T. The effect of the static bias field was also studied in the range of 0-3 T. The temperature of the sample surface was measured using a resistance temperature sensor. The temperature increased with the magnitude of the applied pulsed magnetic field, and the amount of temperature rise decreased with increasing static bias field.

  19. Pulsed magnetic field study of the spin gap in intermediate valence compound SmB 6

    Science.gov (United States)

    Flachbart, K.; Bartkowiak, M.; Demishev, S.; Gabani, S.; Glushkov, V.; Herrmannsdorfer, T.; Moshchalkov, V.; Shitsevalova, N.; Sluchanko, N.

    2009-10-01

    In this work, we report the behavior of electrical resistivity of SmB 6 at temperatures between 2.2 and 70 K in pulsed magnetic fields up to 54 T. A strong negative magnetoresistance was detected with increasing magnetic field, when lowering the temperature in the range T30 K is discussed within the framework of exciton-polaron model of local charge fluctuations in SmB 6 proposed by Kikoin and Mishchenko. It seems that these exciton-polaron in-gap states are influenced both by temperature and magnetic field.

  20. Pulsed high field magnets. An efficient way of shaping laser accelerated proton beams for application

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Florian; Schramm, Ulrich [Helmholtz-Zentrum Dresden - Rossendorf, 01328 Dresden (Germany); Technische Universitaet Dresden, 01062 Dresden (Germany); Bagnoud, Vincent; Blazevic, Abel; Busold, Simon [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Helmholtz Institut Jena, 07734 Jena (Germany); Brabetz, Christian; Schumacher, Dennis [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Deppert, Oliver; Jahn, Diana; Roth, Markus [Technische Universitaet Darmstadt, 64289 Darmstadt (Germany); Karsch, Leonhard; Masood, Umar [OncoRay-National Center for Radiation Research in Oncology, TU Dresden, 01307 Dresden (Germany); Kraft, Stephan [Helmholtz-Zentrum Dresden - Rossendorf, 01328 Dresden (Germany)

    2015-07-01

    Compact laser-driven proton accelerators are a potential alternative to complex, expensive conventional accelerators, enabling unique beam properties, like ultra-high pulse dose. Nevertheless, they still require substantial development in reliable beam generation and transport. We present experimental studies on capture, shape and transport of laser and conventionally accelerated protons via pulsed high-field magnets. These magnets, common research tools in the fields of solid state physics, have been adapted to meet the demands of laser acceleration experiments.Our work distinctively shows that pulsed magnet technology makes laser acceleration more suitable for application and can facilitate compact and efficient accelerators, e.g. for material research as well as medical and biological purposes.

  1. Microstructure refinement of AZ91D alloy solidified with pulsed magnetic field

    Institute of Scientific and Technical Information of China (English)

    WANG Bin; YANG Yuan-sheng; ZHOU Ji-xue; TONG Wen-hui

    2008-01-01

    The effects of pulsed magnetic field on the solidified microstructure of an AZ91D magnesium alloy were investigated. The experimental results show that the remarkable microstructural refinement is achieved when the pulsed magnetic field is applied in the solidification of AZ91D alloy. The average grain size of the as-cast microstructure of AZ91D alloy is refined to 104μm. Besides the grain refinement, the morphology of the primary α-Mg is changed from dendritic to rosette, then to globular shape with changing the parameters of the pulsed magnetic field. The pulsed magnetic field causes melt convection during solidification, which makes the temperature of the whole melt homogenized, and produces an undercooling zone in front of the liquid/solid interface by the magnetic pressure, which makes the nucleation rate increased and big dendrites prohibited. In addition, primary α-Mg dendrites break into fine crystals, resulting in a refined solidification structure of the AZ91D alloy. The Joule heat effect induced in the melt also strengthens the grain refinement effect and spheroidization of dendrite arms.

  2. The effects of samarium-cobalt magnets and pulsed electromagnetic fields on tooth movement.

    Science.gov (United States)

    Darendeliler, M A; Sinclair, P M; Kusy, R P

    1995-06-01

    The purpose of this study was to determine whether the application of either samarium cobalt magnets or pulsed electromagnetic fields could increase the rate and amount of orthodontic tooth movement observed in guinea pigs. In addition, the objective was to evaluate the effect of a magnetic field on bony physiology and metabolism and to monitor for possible systemic side effects. Fifteen grams of laterally directed orthodontic force were applied to move the maxillary central incisors of a sample of 18 young male Hartley guinea pigs divided into three groups: group 1, an orthodontic coil spring was used to move the incisors; group 2, a pair of samarium-cobalt magnets provided the tooth moving force; and group 3, a coil spring was used in combination with a pulsed electromagnetic field. The results showed that both the static magnetic field produced by the samarium-cobalt magnets and the pulsed electromagnetic field used in combination with the coil spring were successful in increasing the rate of tooth movement over that produced by the coil springs alone. The mechanism producing this effect appears to have involved a reduction in the "lag" phase often seen in orthodontic tooth movement. Both magnetically stimulated groups also showed increases in both the organization and amount of new bone deposited in the area of tension between the orthodontically moved maxillary incisors.

  3. Characterisation of practical high temperature superconductors in pulsed magnetic fields and development of associated technology

    CERN Document Server

    Saleh, P M

    2000-01-01

    including a innovative design of a 100ms pulsed magnet solenoid. Critical current measurements on state of the art practical high temperature superconductors are presented. Bi sub 2 Sr sub 2 CaCu sub 2 O silver-alloy matrix powder-in-tube and silver-alloy substrate dip-coated tapes, formed into various geometries, have been tested in pulsed magnetic fields of various pulse lengths. These measurements have been compared to tests performed in continuous magnetic fields. A distinct discrepancy between pulsed and continuous measurements has been observed in these silver-alloy, high temperature superconductor composites. The critical current measured in pulsed fields is depressed compared to those measured in continuous fields. Evidence is provided to strongly suggest that eddy current heating in the silver-alloy substrate/sheath of the conductor is responsible for this discrepancy. A model is presented to predict the temperature rise due to eddy current heating. This model shows good agreement with observations. ...

  4. Spin-orbit interaction in chiral carbon nanotubes probed in pulsed magnetic fields

    NARCIS (Netherlands)

    Jhang, S.H.; Marganska, M.; Skourski, Y.; Preusche, D.; Witkamp, B.; Grifoni, M.; Van der Zant, H.; Wosnitza, J.; Strunk, C.

    2010-01-01

    The magnetoconductance of an open carbon nanotube (CNT)-quantum wire was measured in pulsed magnetic fields. At low temperatures, we find a peculiar split magnetoconductance peak close to the chargeneutrality point. Our analysis of the data reveals that this splitting is intimately connected to the

  5. REMANENCE MEASUREMENTS ON INDIVIDUAL MAGNETOTACTIC BACTERIA USING A PULSED MAGNETIC-FIELD

    NARCIS (Netherlands)

    PENNINGA, Ietje; Waard , de Hendrik; MOSKOWITZ, BM; BAZYLINSKI, DA; FRANKEL, RB

    1995-01-01

    We describe pulsed-magnetic-field remanence measurements of individual, killed, undisrupted cells of three different types of magnetotactic bacteria. The measurement technique involved the observation of aligned, individual magnetotactic bacteria with a light microscope as they were subjected to mag

  6. NMR in pulsed high-field magnets and application to high-T(C) superconductors.

    Science.gov (United States)

    Stork, H; Bontemps, P; Rikken, G L J A

    2013-09-01

    This article deals with the implementation of Nuclear Magnetic Resonance (NMR) experiments in pulsed magnetic fields at the pulsed-field facility of the Laboratoire National des Champs Magnétiques Intenses and its application to the high-T(C) superconductor YBa2Cu3O6.51. The experimental setup is described in detail, including a low-temperature probe head adapted for pulsed fields. An entire paragraph is dedicated to the discussion of NMR in pulsed field and the introduction of an advanced deconvolution technique making use of the induction voltage in an additional pick-up coil. The (63)Cu/(65)Cu NMR experiments on an YBa2Cu3O6.51 single crystal were performed at 2.5K during a field pulse of 46.8-T-amplitude. In the recorded spectrum the (63)Cu center line and high-frequency satellites as well as the (65)Cu center line are identified and are compared with results in literature.

  7. Self-resonant Coil for Contactless Electrical Conductivity Measurement under Pulsed Ultra-high Magnetic Fields

    CERN Document Server

    Nakamura, Daisuke; Takeyama, Shojiro

    2014-01-01

    In this study, we develop experimental apparatus for contactless electrical conductivity measurements under pulsed high magnetic fields over 100 T using a self-resonant-type high-frequency circuit. The resonant power spectra were numerically analyzed, and the conducted simulations showed that the apparatus is optimal for electrical conductivity measurements of materials with high electrical conductivity. The newly developed instruments were applied to a high-temperature cuprate superconductor La$_{2-x}$Sr$_x$CuO$_4$ to show conductivity changes in magnetic fields up to 102 T with a good signal-to-noise ratio. The upper critical field was determined with high accuracy.

  8. Pulsed magnetic field measurement system based on colossal magnetoresistance-B-scalar sensors for railgun investigation.

    Science.gov (United States)

    Stankevič, T; Medišauskas, L; Stankevič, V; Balevičius, S; Żurauskienė, N; Liebfried, O; Schneider, M

    2014-04-01

    A high pulsed magnetic field measurement system based on the use of CMR-B-scalar sensors was developed for the investigations of the electrodynamic processes in electromagnetic launchers. The system consists of four independent modules (channels) which are controlled by a personal computer. Each channel is equipped with a CMR-B-scalar sensor connected to the measurement device-B-scalar meter. The system is able to measure the magnitude of pulsed magnetic fields from 0.3 T to 20 T in the range from DC up to 20 kHz independently of the magnetic field direction. The measurement equipment circuit is electrically separated from the ground and shielded against low and high frequency electromagnetic noise. The B-scalar meters can be operated in the presence of ambient pulsed magnetic fields with amplitudes up to 0.2 T and frequencies higher than 1 kHz. The recorded signals can be transmitted to a personal computer in a distance of 25 m by means of a fiber optic link. The system was tested using the electromagnetic railgun RAFIRA installed at the French-German Research Institute of Saint-Louis, France.

  9. Experimental studies on extremely low frequency pulsed magnetic field inhibiting sarcoma and enhancing cellular immune functions

    Institute of Scientific and Technical Information of China (English)

    张沪生; 叶晖; 张传清; 曾繁清; 黄兴鼎; 张晴川; 李宗山; 杜碧

    1997-01-01

    The previous observation with an electron microscope showed that extremely low frequency (ELF) pulsed magnetic field (PMF) (with the maximum intensity of 0. 6-2. 0 T, gradient of 10-100 T. M-1, pulse width of 20-200 ms and frequency of 0. 16-1. 34 Hz) inhibited the growth of S-180 sarcoma in mice and enhanced the ability of immune cell’s dissolving sarcoma cells. In this study, the DNA contents of nuclei were assayed by using Faulgen Staining method. With an electron microscope and cell stereoscopy technology it was observed that magnetic field affected the sarcoma cell’s metabolism, lowered its malignancy, and restrained its rapid and heteromorphic growth. The magnetic field enhanced the cellular immune ability and the reaction of lymphocytes and plasma. Since ELF pulsed magnetic fields can inhibit the growth of sarcomas and enhance the cellular immune ability, it is possible to use it as a new method to treat cancer.

  10. Effect of structural steel ion plasma nitriding on material durability in pulsed high magnetic fields

    Science.gov (United States)

    Spirin, A. V.; Krutikov, V. I.; Koleukh, D. S.; Mamaev, A. S.; Paranin, S. N.; Gavrilov, N. V.; Kaigorodov, A. S.

    2017-05-01

    The work was aimed to study the influence of plasma nitriding on electrical and mechanical properties of structural steels and their durability in pulsed high magnetic field. The plates and cylindrical magnetic flux concentrators were made of several steel grades (30KhGS, 40Kh, 50KhGA, 38Kh2MYuA, and U8A), heat-treated, and subjected to the low-temperature (400, 500°C) plasma nitriding. Electrical and mechanical properties of materials, phase composition of steel surface layer, microstructure and microhardness profiles were investigated on the plates before and after plasma treatment. Microstructure and microhardness profiles across the subsurface layer of plasma treated and untreated concentrators applied for high magnetic field generation were also studied. Magnetic field of 50 T under tens of microseconds in duration inside the flux concentrators was generated by long-life outer coil.

  11. An Optimization of Pulsed ElectroMagnetic Fields Study

    Science.gov (United States)

    Goodwin, Thomas J.

    2006-01-01

    To date, in our research we have focused on the use of normal human neuronal progenitor (NHNP) cells because of their importance in human nervous system regeneration, development and maintenance, but we have developed 2-D and 3-D bioreactors that can accommodate any cell line. In this Project, we will include the use of tissues important for physiological regeneration: Human osteoblasts or chondrocytes, and vascular cells. Our initial results with the NHNP cells were quite startling using extremely low-level electromagnetic fields (5 microtesla at 10Hz; 6mA). The low-amplitude, rapidly time-varying electromagnetic fields exert a very potent effect on the proliferation, morphology, and gene expression of the cells in culture, both in standard 2-dimensional culture plates as well as cells organized into 3-dimensional tissue-like assemblies (TLAs) in a 3D bioreactor. We have replicated our preliminary results many, many times, have analyzed the gene expression using gene arrays (followed by Luminex analysis for protein production), and have monitored cell proliferation, orientation, morphology, and glucose metabolism, and we are confident that we have a stable and reliable model to study the control of high-level cellular processes by application of low-amplitude, time varying electromagnetic fields (TVEMF) (1, 2). In additional studies at the University of Michigan, we have been able to generate functional in vitro engineered mammalian skeletal muscle, and have employed nerve-muscle co-culture techniques to promote axonal sprouting. We believe that nearly all tissues, in particular, neural, are susceptible to the influences of low-level TVEMF.

  12. Trapped fields up to 2 T in a 12 mm square stack of commercial superconducting tape using pulsed field magnetization

    Science.gov (United States)

    Patel, A.; Hopkins, S. C.; Glowacki, B. A.

    2013-03-01

    The ability of superconductors to sustain persistent currents has been well exploited with (RE)BCO superconducting bulks, which can be magnetized to form a compact source of high magnetic field. However, thin films can also sustain persistent currents, which can be utilized by stacking them in layers to create a type of composite bulk. Such a stack is capable of trapping higher fields than a bulk, as reported in this paper. 12 mm wide, 55 μm thick commercial (RE)BCO tape from Superpower Inc was cut into 12 mm by 12 mm squares, stacked together and magnetized at temperatures between 10 and 77.4 K using a sequence of pulsed magnetic fields. The results are compared to a commercial 14 mm diameter YBCO bulk, showing that the stack of tapes outperformed the bulk at temperatures below approximately 60 K. Particularly high trapped fields were achieved below 50 K, with a maximum of 2.0 T at 10 K measured 0.8 mm from the stack surface. The maximum trapped field possible for a stack of tapes increases significantly with decreasing temperature down to 10 K, rather than saturating at a higher temperature as in the case of a bulk, due to superior thermal stability. The Jc, thermal and mechanical properties of commercial (RE)BCO tapes give them great potential for use as trapped field magnets activated by pulsed magnetic fields.

  13. The separated electric and magnetic field responses of luminescent bacteria exposed to pulsed microwave irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Catrin F., E-mail: williamscf@cardiff.ac.uk [School of Engineering, Cardiff University, Queen' s Buildings, Newport Road, Cardiff, CF24 3AA Wales (United Kingdom); School of Biosciences, Cardiff University, Main Building, Cathays Park, Cardiff, CF10 3AT Wales (United Kingdom); Geroni, Gilles M.; Pirog, Antoine; Lees, Jonathan; Porch, Adrian [School of Engineering, Cardiff University, Queen' s Buildings, Newport Road, Cardiff, CF24 3AA Wales (United Kingdom); Lloyd, David [School of Biosciences, Cardiff University, Main Building, Cathays Park, Cardiff, CF10 3AT Wales (United Kingdom)

    2016-08-29

    Electromagnetic fields (EMFs) are ubiquitous in the digital world we inhabit, with microwave and millimetre wave sources of non-ionizing radiation employed extensively in electronics and communications, e.g., in mobile phones and Wi-Fi. Indeed, the advent of 5G systems and the “internet of things” is likely to lead to massive densification of wireless networks. Whilst the thermal effects of EMFs on biological systems are well characterised, their putative non-thermal effects remain a controversial subject. Here, we use the bioluminescent marine bacterium, Vibrio fischeri, to monitor the effects of pulsed microwave electromagnetic fields, of nominal frequency 2.5 GHz, on light emission. Separated electric and magnetic field effects were investigated using a resonant microwave cavity, within which the maxima of each field are separated. For pulsed electric field exposure, the bacteria gave reproducible responses and recovery in light emission. At the lowest pulsed duty cycle (1.25%) and after short durations (100 ms) of exposure to the electric field at power levels of 4.5 W rms, we observed an initial stimulation of bioluminescence, whereas successive microwave pulses became inhibitory. Much of this behaviour is due to thermal effects, as the bacterial light output is very sensitive to the local temperature. Conversely, magnetic field exposure gave no measurable short-term responses even at the highest power levels of 32 W rms. Thus, we were able to detect, de-convolute, and evaluate independently the effects of separated electric and magnetic fields on exposure of a luminescent biological system to microwave irradiation.

  14. The separated electric and magnetic field responses of luminescent bacteria exposed to pulsed microwave irradiation

    Science.gov (United States)

    Williams, Catrin F.; Geroni, Gilles M.; Pirog, Antoine; Lloyd, David; Lees, Jonathan; Porch, Adrian

    2016-08-01

    Electromagnetic fields (EMFs) are ubiquitous in the digital world we inhabit, with microwave and millimetre wave sources of non-ionizing radiation employed extensively in electronics and communications, e.g., in mobile phones and Wi-Fi. Indeed, the advent of 5G systems and the "internet of things" is likely to lead to massive densification of wireless networks. Whilst the thermal effects of EMFs on biological systems are well characterised, their putative non-thermal effects remain a controversial subject. Here, we use the bioluminescent marine bacterium, Vibrio fischeri, to monitor the effects of pulsed microwave electromagnetic fields, of nominal frequency 2.5 GHz, on light emission. Separated electric and magnetic field effects were investigated using a resonant microwave cavity, within which the maxima of each field are separated. For pulsed electric field exposure, the bacteria gave reproducible responses and recovery in light emission. At the lowest pulsed duty cycle (1.25%) and after short durations (100 ms) of exposure to the electric field at power levels of 4.5 W rms, we observed an initial stimulation of bioluminescence, whereas successive microwave pulses became inhibitory. Much of this behaviour is due to thermal effects, as the bacterial light output is very sensitive to the local temperature. Conversely, magnetic field exposure gave no measurable short-term responses even at the highest power levels of 32 W rms. Thus, we were able to detect, de-convolute, and evaluate independently the effects of separated electric and magnetic fields on exposure of a luminescent biological system to microwave irradiation.

  15. Modelling and comparison of trapped fields in (RE)BCO bulk superconductors for activation using pulsed field magnetization

    Science.gov (United States)

    Ainslie, M. D.; Fujishiro, H.; Ujiie, T.; Zou, J.; Dennis, A. R.; Shi, Y.-H.; Cardwell, D. A.

    2014-06-01

    The ability to generate a permanent, stable magnetic field unsupported by an electromotive force is fundamental to a variety of engineering applications. Bulk high temperature superconducting (HTS) materials can trap magnetic fields of magnitude over ten times higher than the maximum field produced by conventional magnets, which is limited practically to rather less than 2 T. In this paper, two large c-axis oriented, single-grain YBCO and GdBCO bulk superconductors are magnetized by the pulsed field magnetization (PFM) technique at temperatures of 40 and 65 K and the characteristics of the resulting trapped field profile are investigated with a view of magnetizing such samples as trapped field magnets (TFMs) in situ inside a trapped flux-type superconducting electric machine. A comparison is made between the temperatures at which the pulsed magnetic field is applied and the results have strong implications for the optimum operating temperature for TFMs in trapped flux-type superconducting electric machines. The effects of inhomogeneities, which occur during the growth process of single-grain bulk superconductors, on the trapped field and maximum temperature rise in the sample are modelled numerically using a 3D finite-element model based on the H-formulation and implemented in Comsol Multiphysics 4.3a. The results agree qualitatively with the observed experimental results, in that inhomogeneities act to distort the trapped field profile and reduce the magnitude of the trapped field due to localized heating within the sample and preferential movement and pinning of flux lines around the growth section regions (GSRs) and growth sector boundaries (GSBs), respectively. The modelling framework will allow further investigation of various inhomogeneities that arise during the processing of (RE)BCO bulk superconductors, including inhomogeneous Jc distributions and the presence of current-limiting grain boundaries and cracks, and it can be used to assist optimization of

  16. Mechanical Studies on Treatment of Malignant Tumour by Ultralow Frequency Pulsed- Gradient Magnetic Fields

    Institute of Scientific and Technical Information of China (English)

    Deng Ren-qing; Liu Qing-hua; Zhang Hu-sheng

    2003-01-01

    Ultralow frequency (ULF) pulsed-gradient magnetic field (with the maximum intensity of 0. 6-2. 0 T,gradient of 10-100 T @ m-1 , pulse width of 20-200 ms and frequency of 0. 16-1. 34 Hz) treatment of mice can inhibit murine malignant tumour growth and can induce apoptosis of cancer cell. The apoptotic cancer cell contracted, became rounder and divorced from adjacent cells; the heterochromatin condensed and coagulated together along the inner side of the nuclear membrane; the endoplasmic reticulums expanded and fused with the cellular membrane; many apoptotic bodies which were packed by the cellular membrane appeared and were devoured by some lymphocytes and plasma. By Lorentz force the magnetic field keeps the moving ions within bounds of Larmor radius. Thus, penetrating capability of the positive and negative ions through the cell membrane was affected,even the role on the cell membrane formed.

  17. Nonperturbative measurement of the local magnetic field using pulsed polarimetry for fusion reactor conditions (invited).

    Science.gov (United States)

    Smith, Roger J

    2008-10-01

    A novel diagnostic technique for the remote and nonperturbative sensing of the local magnetic field in reactor relevant plasmas is presented. Pulsed polarimetry [Patent No. 12/150,169 (pending)] combines optical scattering with the Faraday effect. The polarimetric light detection and ranging (LIDAR)-like diagnostic has the potential to be a local B(pol) diagnostic on ITER and can achieve spatial resolutions of millimeters on high energy density (HED) plasmas using existing lasers. The pulsed polarimetry method is based on nonlocal measurements and subtle effects are introduced that are not present in either cw polarimetry or Thomson scattering LIDAR. Important features include the capability of simultaneously measuring local T(e), n(e), and B(parallel) along the line of sight, a resiliency to refractive effects, a short measurement duration providing near instantaneous data in time, and location for real-time feedback and control of magnetohydrodynamic (MHD) instabilities and the realization of a widely applicable internal magnetic field diagnostic for the magnetic fusion energy program. The technique improves for higher n(e)B(parallel) product and higher n(e) and is well suited for diagnosing the transient plasmas in the HED program. Larger devices such as ITER and DEMO are also better suited to the technique, allowing longer pulse lengths and thereby relaxing key technology constraints making pulsed polarimetry a valuable asset for next step devices. The pulsed polarimetry technique is clarified by way of illustration on the ITER tokamak and plasmas within the magnetized target fusion program within present technological means.

  18. Control of transmission of right circularly polarized laser light in overdense plasma by applied magnetic field pulses.

    Science.gov (United States)

    Ma, Guangjin; Yu, Wei; Yu, M Y; Luan, Shixia; Wu, Dong

    2016-05-01

    The effect of a transient magnetic field on right-hand circularly polarized (RHCP) laser light propagation in overcritical-density plasma is investigated. When the electron gyrofrequency is larger than the wave frequency, RHCP light can propagate along the external magnetic field in an overcritical density plasma without resonance or cutoff. However, when the magnetic field falls to below the cyclotron resonance point, the propagating laser pulse will be truncated and the local plasma electrons resonantly heated. Particle-in-cell simulation shows that when applied to a thin slab, the process can produce intense two-cycle light pulses as well as long-lasting self-magnetic fields.

  19. Elastic properties of SmRu4P12 in pulsed magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Sun, P [Graduate School of Engineering, Iwate University, Morioka 020-8551 (Japan); Nakanishi, Y [Graduate School of Engineering, Iwate University, Morioka 020-8551 (Japan); Kono, T [Superconductivity Research Laboratory, ISTEC, Morioka Laboratory for Applied Superconductivity Technology, Morioka 020-0852 (Japan); Sugawara, H [Faculty of Integrated Arts and Science, University of Tokushima, Tokushima 770-8502 (Japan); Kikuchi, D [Graduate School of Science, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Sato, H [Graduate School of Science, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Yoshizawa, M [Graduate School of Engineering, Iwate University, Morioka 020-8551 (Japan)

    2006-11-15

    A setup for ultrasonic measurement in pulsed magnetic fields was established in this work. We first introduce the basic ideas of this measurement. Using this setup we measured the longitudinal elastic constant C{sub 11} and the corresponding ultrasound attenuation {beta}{sub 11} up to 28 T for the filled skutterudite compound SmRu{sub 4}P{sub 12}. At 14 K, C{sub 11} shows steep increase while {beta}{sub 11}a large peak at around 8 T, indicating the magnetic ordering of this compound. Anomalies were also observed at 4.2 K, however, it is not clear if these correspond to phase transitions.

  20. An atomic coilgun: using pulsed magnetic fields to slow a supersonic beam

    Energy Technology Data Exchange (ETDEWEB)

    Narevicius, E [Center for Nonlinear Dynamics and Department of Physics, Univesity of Texas at Austin, Austin, TX 78712-1081 (United States); Parthey, C G [Center for Nonlinear Dynamics and Department of Physics, Univesity of Texas at Austin, Austin, TX 78712-1081 (United States); Libson, A [Center for Nonlinear Dynamics and Department of Physics, Univesity of Texas at Austin, Austin, TX 78712-1081 (United States); Narevicius, J [Center for Nonlinear Dynamics and Department of Physics, Univesity of Texas at Austin, Austin, TX 78712-1081 (United States); Chavez, I [Center for Nonlinear Dynamics and Department of Physics, Univesity of Texas at Austin, Austin, TX 78712-1081 (United States); Even, U [Sackler School of Chemistry, Tel-Aviv University, Tel-Aviv (Israel); Raizen, M G [Center for Nonlinear Dynamics and Department of Physics, Univesity of Texas at Austin, Austin, TX 78712-1081 (United States)

    2007-10-15

    We report the experimental demonstration of a novel method to slow atoms and molecules with permanent magnetic moments using pulsed magnetic fields. In our experiments, we observe the slowing of a supersonic beam of metastable neon from 461.0 {+-} 7.7 to 403 {+-} 16 m s{sup -1} in 18 stages, where the slowed peak is clearly separated from the initial distribution. This method has broad applications as it may easily be generalized, using seeding and entrainment into supersonic beams, to all paramagnetic atoms and molecules.

  1. Effects of Pulsed Current and Pulsed Magnetic Field Complex Pretreatment on Martensite Transformation of Cr5 Steel during Continuous Cooling

    Institute of Scientific and Technical Information of China (English)

    Qing-chun LI; Li-juan LI; Guo-wei CHANG; Qi-jie ZHAI

    2015-01-01

    Carbide precipitation and martensite transformation in Cr5 steel have been observed in situ by high-temper-ature confocal laser-scanning microscopy.In this way,the influences of pulsed current and pulsed magnetic field complex pretreatment on carbide precipitation and martensite transformation during continuous cooling have been studied.The results show that the electropulsing complex pretreatment promotes the precipitation of M7 C3-type car-bides at high temperature,increases the start and finish temperatures of martensite transformation,and extends the phase transformation time.Martensite prefers to nucleate in the austenite with less precipitation of carbides due to the chemically homogeneous distribution of solute atoms.

  2. Magnetic Pulse Welding Technology

    Directory of Open Access Journals (Sweden)

    Ahmad K. Jassim

    2011-12-01

    Full Text Available In this paper, the benefits of using Magnetic Pulse machine which is belong to Non-conventional machine instead of conventional machine. Magnetic Pulse Technology is used for joining dissimilar metals, and for forming and cutting metals. It is a non contact technique. Magnetic field is used to generate impact magnetic pressure for welding and forming the work piece by converted the electrical energy to mechanical energy. It is enable us to design previously not possible by welding dissimilar materials and allowing to welds light and stronger materials together. It can be used to weld metallic with non metallic materials to created mechanical lock on ceramics, polymers, rubbers and composites. It is green process; there is no heat, no radiation, no gas, no smoke and sparks, therefore the emissions are negligible.

  3. Trapped field of YBCO single-domain samples using pulse magnetization from 77K to 20K

    Energy Technology Data Exchange (ETDEWEB)

    Chaud, X [CNRS/CRETA, 25 avenue des martyrs, 38042 Grenoble Cedex 09 (France); Haanappel, E [LNCMP, 143 avenue de Rangueil, 31400 Toulouse (France); Noudem, J G; Horvath, D [CRISMAT/ENSICAEN, 6 bd Marechal Juin, 14050 Caen (France)], E-mail: xavier.chaud@grenoble.cnrs.fr

    2008-02-01

    ReBCO single-domain bulk superconductors have been shown to trap significant magnetic field at 77K and below. They can advantageously replace permanent magnets in cryogenic motors; more power in a smaller volume can be achieved. But practically, their magnetization has to be performed in situ. Usually it implies the use of pulse magnetization which is severe for the samples. This technique generates heat and stress on the superconductors. The magnetic-flux-trapping capabilities of YBCO single-domain samples were explored using the pulse-field facilities at the LNCMP (National Pulsed Magnetic Field Laboratory) at Toulouse, France. The flux dynamic was monitored during magnetic pulses by measuring the surface induction with a Hall probe on top of the samples at different temperatures from 77K to 20K. The samples were 16 mm in diameter and about 10 mm in height. The best one trapped 400 mT at 77K and 2.5T at 20K. The trapped field increases almost linearly down to 40K. The magnetic pulse is seen to generate heat. The temperature rise increases with decreasing temperature dwell because of lower heat capacity. The achieved trapped field is a compromise between the temperature rise and the applied field, and depends greatly of the magnetization history.

  4. Interaction of CO2 laser pulses with solid targets in magnetic fields

    Science.gov (United States)

    Loter, N. G.; Halverson, W.; Lax, B.

    1981-08-01

    High-temperature plasmas were generated by focussing 225-J gain-switched CO2 laser pulses onto planar solid targets within the bore of a Bitter solenoid magnet. DC magnetic fields up to 100 kG were applied parallel to the laser propagation vector, partially confining a long plasma column streaming away from the target. Target materials included teflon (CF2), graphite, and Al. Soft x-ray diagnostics, including a dual-channel, time-resolving TAP crystal spectrometer, a pinhole camera, and differentially-filtered p-i-n diodes, were used to determine electron density, electron temperature, and axial and radial expansion characteristics of the plasma. From these measurements, it was deduced that effects of refraction became increasingly important as B was increased; furthermore, these effects were strongly dependent on target material. For all targets, refraction occurred late in the pulse when the radially confined plasmas left the focal volume. For teflon and aluminum targets, but not for the lower Z graphite targets, it was inferred that significant side scattering also occurred early in the pulse with sufficiently strong magnetic fields.

  5. The imprint of the crustal magnetic field on the thermal spectra and pulse profiles of isolated neutron stars

    CERN Document Server

    Perna, Rosalba; Pons, Jose' A; Rea, Nanda

    2013-01-01

    Isolated neutron stars (NSs) show a bewildering variety of astrophysical manifestations, presumably shaped by the magnetic field strength and topology at birth. Here, using state-of-the art calculations of the coupled magnetic and thermal evolution of NSs, we compute the thermal spectra and pulse profiles expected for a variety of initial magnetic field configurations. In particular, we contrast models with purely poloidal magnetic fields to models dominated by a strong internal toroidal component. We find that, while the former displays double peaked profiles and very low pulsed fractions, in the latter, the anisotropy in the surface temperature produced by the toroidal field often results in a single pulse profile, with pulsed fractions that can exceed the 50-60% level even for perfectly isotropic local emission. We further use our theoretical results to generate simulated "observed" spectra, and show that blackbody (BB) fits result in inferred radii that can be significantly smaller than the actual NS radi...

  6. AC measurement of heat capacity and magnetocaloric effect for pulsed magnetic fields

    OpenAIRE

    2010-01-01

    International audience; A new calorimeter for measurements of the heat capacity and magnetocaloric effect of small samples in pulsed magnetic fields is discussed for the exploration of thermal and thermodynamic properties at temperatures down to 2 K. We tested the method up to 0H=50 T, but it could be extended to higher fields. For these measurements we used carefully calibrated bare-chip Cernox® and RuO2 thermometers, and we present a comparison of their performances. The monotonic temperatu...

  7. A Cryogen-free Cryostat for Scientific Experiment in Pulsed High Magnetic Fields

    Science.gov (United States)

    Wang, Shaoliang; Li, Liang; Zuo, Huakun; Liu, Mengyu; Peng, Tao

    Traditional cryostats for scientific experiments in pulsed high magnetic fields use liquid helium as the cooling source. To reduce the running cost and to increase the operational efficiency, a cryogen-free cryostat based on a GM cryocooler has been developed for a 60 T pulsed field measurement cell at Wuhan National High Magnetic Field Center. A double layer temperature-control insert was designed to obtain a stable temperature in the sample chamber of the cryostat. In order to eliminate the sample temperature fluctuation caused by the eddy current heating during the pulse, the inner layer is made from a fiberglass tubing with an epoxy coating. Different from the traditional cryostat, the sample and the temperature controller are not immerged in the 4He bath. Instead, they are separated by helium gas under sub-atmospheric pressure, which makes the heat transfer smoother. At the sample position, a resistance heater wound with antiparallel wires is mounted on the inner layer to heat the sample. Using the temperature-control insert, the temperature can be controlled with an accuracy of ±0.01 K in the range of 1.4 K-20 K, and ±0.05 K between 20 K and 300 K.

  8. AC measurement of heat capacity and magnetocaloric effect for pulsed magnetic fields.

    Science.gov (United States)

    Kohama, Yoshimitsu; Marcenat, Christophe; Klein, Thierry; Jaime, Marcelo

    2010-10-01

    A new calorimeter for measurements of the heat capacity and magnetocaloric effect of small samples in pulsed magnetic fields is discussed for the exploration of thermal and thermodynamic properties at temperatures down to 2 K. We tested the method up to μ(0)H=50 T, but it could be extended to higher fields. For these measurements we used carefully calibrated bare-chip Cernox(®) and RuO(2) thermometers, and we present a comparison of their performances. The monotonic temperature and magnetic field dependences of the magnetoresistance of RuO(2) allow thermometry with a precision as good as ±4 mK at T=2 K. To test the performance of our calorimeter, heat capacity and magnetocaloric effect for the spin-dimer compound Sr(3)Cr(2)O(8) and the triangular lattice antiferromagnet RbFe(MoO(4))(2) are presented.

  9. Irreversible magnetoporation of micro-organisms in high pulsed magnetic fields.

    Science.gov (United States)

    Novickij, Vitalij; Grainys, Audrius; Novickij, Jurij; Markovskaja, Svetlana

    2014-09-01

    Electroporation is an appealing way of stimulating living cells, which causes permanent or temporary nanoporosities in the structure of the biological objects. However, the technique has a disadvantage such as a requirement of contact between the electrodes and the cell medium. In this review, a methodology of contactless treatment of the biological objects using pulsed magnetic fields is proposed. The eukaryotic micro-organisms Achlya americana and Saprolegnia diclina have been used in the study and magnetic fields up to 7 T were applied, which caused effects similar to irreversible electroporation resulting in the death of the species. The proposed technique is applicable for different types of the biological cells or micro-organisms and possibly can be used in the area of cancer, antifungal treatment and other biotechnological fields.

  10. Zylon-reinforced high magnetic field coils for the K.U. Leuven pulsed field laboratory

    Science.gov (United States)

    Rosseel, K.; Herlach, F.; Boon, W.; Bruynseraede, Y.

    2001-01-01

    PBO Zylon ® fibers have been used for the internal reinforcement of pulsed magnets. Due to the very high packing density (80%) of these fibers, vacuum impregnation of Zylon reinforced coils is difficult. Impregnation test were performed using pressure-vacuum impregnation and wet winding. A prototype series of coils for 60-70 T with 1-2 ms pulse duration was designed and wound, using wet winding for both the internal Zylon and external carbon fiber reinforcement. Special precautions were taken to avoid insulation breakdown at the transitions between conductor layers. Furthermore, axial movement of the conductor wires was restrained by strong axial compression of the coil with a steel shell casing. These modifications were incorporated into an 80 T coil made of Zylon and soft Cu. The design, construction and performance of this coil are discussed.

  11. Magnetosome formation and expression of mamA, mms13, mms6 and magA in Magnetospirillum magneticum AMB-1 exposed to pulsed magnetic field.

    Science.gov (United States)

    Wang, Xiaoke; Liang, Likun; Song, Tao; Wu, Longfei

    2009-09-01

    To investigate the effects of pulsed magnetic field on magnetosome formation in Magnetospirillum magneticum AMB-1, cultures inoculated with either mangetic or non-magnetic pre-cultures were incubated under 1 mT pulsed magnetic field. Magnetism of cells was measured by using spectrophotometer coupled with applied magnetic fields and the values were described as C(mag). Magnetosome in cells was counted by transmission electron microscopy observation. The results showed that pulsed magnetic field did not affect cellular growth, but enhanced magnetosome formation. The applied pulsed magnetic field might exceed the chain of magnetosomes and change the homogeneity of the magnetosome particles. The results implied that magnetite precipitation induced by the adjacent magnetosome was affected by pulsed magnetic field. Moreover, the applied pulsed magnetic field up-regulated the magA and mamA expression in cells, which might account for the increasing number and the exceeding chain of magnetosomes in cells.

  12. High Field Pulsed Magnets for Neutron Scattering at the Spallation Neutron Source

    Science.gov (United States)

    Granroth, G. E.; Lee, J.; Fogh, E.; Christensen, N. B.; Toft-Petersen, R.; Nojiri, H.

    2015-03-01

    A High Field Pulsed Magnet (HFPM) setup, is in use at the Spallation Nuetron Source(SNS), Oak Ridge National Laboratory. With this device, we recently measured the high field magnetic spin structure of LiNiPO4. The results of this study will be highlighted as an example of possible measurements that can be performed with this device. To further extend the HFPM capabilities at SNS, we have learned to design and wind these coils in house. This contribution will summarize the magnet coil design optimization procedure. Specifically by varying the geometry of the multi-layer coil, we arrive at a design that balances the maximum field strength, neutron scattering angle, and the field homogeneity for a specific set of parameters. We will show that a 6.3kJ capacitor bank, can provide a magnetic field as high as 30T for a maximum scattering angle around 40° with homogeneity of +/- 4 % in a 2mm diameter spherical volume. We will also compare the calculations to measurements from a recently wound test coil. This work was supported in part by the Lab Directors' Research and Development Fund of ORNL.

  13. Flux jumps in high-J c MgB2 bulks during pulsed field magnetization

    Science.gov (United States)

    Fujishiro, H.; Mochizuki, H.; Naito, T.; Ainslie, M. D.; Giunchi, G.

    2016-03-01

    Pulsed field magnetization (PFM) of a high-J c MgB2 bulk disk has been investigated at 20 K, in which flux jumps frequently occur for high pulsed fields. Using a numerical simulation of the PFM procedure, we estimated the time dependence of the local magnetic field and temperature during PFM. We analyzed the electromagnetic and thermal instability of the high-J c MgB2 bulk to avoid flux jumps using the time dependence of the critical thickness, d c(t), which shows the upper safety thickness to stabilize the superconductor magnetically, and the minimum propagation zone length, l m(t), to obtain dynamical stability. The values of d c(t) and l m(t) change along the thermally-stabilized direction with increasing temperature below the critical temperature, T c. However, the flux jump can be qualitatively understood by the local temperature, T(t), which exceeds T c in the bulk. Finally, possible solutions to avoid flux jumps in high-J c MgB2 bulks are discussed.

  14. Curling probe measurement of large-volume pulsed plasma confined by surface magnetic field

    Science.gov (United States)

    Pandey, Anil; Sakakibara, Wataru; Matsuoka, Hiroyuki; Nakamura, Keiji; Sugai, Hideo; Chubu University Team; DOWA Thermotech Collaboration

    2015-09-01

    Curling probe (CP) has recently been developed which enables the local electron density measurement even in plasma for non-conducting film CVD. The electron density is obtained from a shift of resonance frequency of spiral antenna in discharge ON and OFF monitored by a network analyzer (NWA). In case of a pulsed glow discharge, synchronization of discharge pulse with frequency sweep of NWA must be established. In this paper, we report time and space-resolved CP measurement of electron density in a large volume plasma (80 cm diameter, 110 cm length) confined by surface magnetic field (multipole cusp field ~0.03 T). For plasma-aided modification of metal surface, the plasma is produced by 1 kV glow discharge at pulse frequency of 0.3 - 25 kHz with various duty ratio in gas (Ar, N2, C2H2) at pressure ~ 1 Pa. A radially movable CP revealed a remarkable effect of surface magnetic confinement: detach of plasma from the vessel wall and a fairly uniform plasma in the central region. In afterglow phase, the electron density was observed to decrease much faster in C2H2 discharge than in Ar discharge.

  15. Time resolved dosimetry of human brain exposed to low frequency pulsed magnetic fields

    Science.gov (United States)

    Paffi, Alessandra; Camera, Francesca; Lucano, Elena; Apollonio, Francesca; Liberti, Micaela

    2016-06-01

    An accurate dosimetry is a key issue to understanding brain stimulation and related interaction mechanisms with neuronal tissues at the basis of the increasing amount of literature revealing the effects on human brain induced by low-level, low frequency pulsed magnetic fields (PMFs). Most literature on brain dosimetry estimates the maximum E field value reached inside the tissue without considering its time pattern or tissue dispersivity. Nevertheless a time-resolved dosimetry, accounting for dispersive tissues behavior, becomes necessary considering that the threshold for an effect onset may vary depending on the pulse waveform and that tissues may filter the applied stimulatory fields altering the predicted stimulatory waveform’s size and shape. In this paper a time-resolved dosimetry has been applied on a realistic brain model exposed to the signal presented in Capone et al (2009 J. Neural Transm. 116 257-65), accounting for the broadband dispersivity of brain tissues up to several kHz, to accurately reconstruct electric field and current density waveforms inside different brain tissues. The results obtained by exposing the Duke’s brain model to this PMF signal show that the E peak in the brain is considerably underestimated if a simple monochromatic dosimetry is carried out at the pulse repetition frequency of 75 Hz.

  16. Single-Shot Terahertz Time-Domain Spectroscopy in Pulsed High Magnetic Fields

    CERN Document Server

    Noe, G Timothy; Katsutani, Fumiya; Allred, James J; Horowitz, Jeffrey A; Zhang, Qi; Sekiguch, Fumiya; Woods, Gary L; Sullivan, David M; Hoffmann, Matthias C; Nojiri, Hiroyuki; Kono, Junichiro

    2016-01-01

    We have developed a single-shot terahertz time-domain spectrometer to perform optical pump/terahertz probe experiments in pulsed, high magnetic fields up to 30 T. The single-shot detection scheme for measuring a terahertz waveform incorporates a reflective echelon to create time-delayed beamlets across the intensity profile of the gate beam before it spatially and temporally overlaps with the terahertz radiation in a ZnTe detection crystal. After imaging the gate beam onto a camera, the terahertz time-domain waveform can be retrieved by analyzing the resulting image. Here, we have measured cyclotron resonance absorption of optically excited carriers in the terahertz frequency range in bulk, intrinsic silicon at high magnetic fields.

  17. Faraday rotation dispersion microscopy imaging of diamagnetic and chiral liquids with pulsed magnetic field.

    Science.gov (United States)

    Suwa, Masayori; Nakano, Yusuke; Tsukahara, Satoshi; Watarai, Hitoshi

    2013-05-21

    We have constructed an experimental setup for Faraday rotation dispersion imaging and demonstrated the performance of a novel imaging principle. By using a pulsed magnetic field and a polarized light synchronized to the magnetic field, quantitative Faraday rotation images of diamagnetic organic liquids in glass capillaries were observed. Nonaromatic hydrocarbons, benzene derivatives, and naphthalene derivatives were clearly distinguished by the Faraday rotation images due to the difference in Verdet constants. From the wavelength dispersion of the Faraday rotation images in the visible region, it was found that the resonance wavelength in the UV region, which was estimated based on the Faraday B-term, could be used as characteristic parameters for the imaging of the liquids. Furthermore, simultaneous acquisition of Faraday rotation image and natural optical rotation image was demonstrated for chiral organic liquids.

  18. High resolution magnetostriction measurements in pulsed magnetic fields using fiber Bragg gratings.

    Science.gov (United States)

    Daou, Ramzy; Weickert, Franziska; Nicklas, Michael; Steglich, Frank; Haase, Ariane; Doerr, Mathias

    2010-03-01

    We report on a new high resolution apparatus for measuring magnetostriction suitable for use at cryogenic temperatures in pulsed high magnetic fields which we have developed at the Hochfeld-Magnetlabor Dresden. Optical fiber strain gauges based on fiber Bragg gratings are used to measure the strain in small (approximately 1 mm) samples. We describe the implementation of a fast measurement system capable of resolving strains in the order of 10(-7) with a full bandwidth of 47 kHz, and demonstrate its use on single crystal samples of GdSb and GdSi.

  19. Pulsed high-magnetic-field experiments: New insights into the magnetocaloric effect in Ni-Mn-In Heusler alloys

    Science.gov (United States)

    Salazar Mejía, C.; Ghorbani Zavareh, M.; Nayak, A. K.; Skourski, Y.; Wosnitza, J.; Felser, C.; Nicklas, M.

    2015-05-01

    The present pulsed high-magnetic-field study on Ni50Mn35In15 gives an extra insight into the thermodynamics of the martensitic transformation in Heusler shape-memory alloys. The transformation-entropy change, ΔS, was estimated from field-dependent magnetization experiments in pulsed high magnetic fields and by heat-capacity measurements in static fields. We found a decrease of ΔS with decreasing temperature. This behavior can be understood by considering the different signs of the lattice and magnetic contributions to the total entropy. Our results further imply that the magnetocaloric effect will decrease with decreasing temperature and, furthermore, the martensitic transition is not induced anymore by changing the temperature in high magnetic fields.

  20. Pulsed high-magnetic-field experiments: New insights into the magnetocaloric effect in Ni-Mn-In Heusler alloys

    Energy Technology Data Exchange (ETDEWEB)

    Salazar Mejía, C., E-mail: Catalina.Salazar@cpfs.mpg.de; Nayak, A. K.; Felser, C.; Nicklas, M. [Max Planck Institute for Chemical Physics of Solids, 01187 Dresden (Germany); Ghorbani Zavareh, M.; Wosnitza, J. [Dresden High Magnetic Field Laboratory (HLD-EMFL), Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden (Germany); Institut für Festkörperphysik, TU Dresden, 01062 Dresden (Germany); Skourski, Y. [Dresden High Magnetic Field Laboratory (HLD-EMFL), Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden (Germany)

    2015-05-07

    The present pulsed high-magnetic-field study on Ni{sub 50}Mn{sub 35}In{sub 15} gives an extra insight into the thermodynamics of the martensitic transformation in Heusler shape-memory alloys. The transformation-entropy change, ΔS, was estimated from field-dependent magnetization experiments in pulsed high magnetic fields and by heat-capacity measurements in static fields. We found a decrease of ΔS with decreasing temperature. This behavior can be understood by considering the different signs of the lattice and magnetic contributions to the total entropy. Our results further imply that the magnetocaloric effect will decrease with decreasing temperature and, furthermore, the martensitic transition is not induced anymore by changing the temperature in high magnetic fields.

  1. Multiplexing Effect Due to Exposure of the Working Substance of a Spin Echo Processor to Magnetic Field Pulses

    Science.gov (United States)

    Pleshakov, I. V.; Popov, P. S.; Kuzmin, Yu. I.; Dudkin, V. I.

    2016-07-01

    We consider a spin echo processor that uses a magnetically ordered material (ferrite) as a working substance. It is shown that it is possible to achieve suppression of the crosstalk (spurious signals) excited by radio-frequency pulses from different chains arriving at the system if the working substance is affected by sufficiently long magnetic field pulses. Thus, time-division multiplexing of the information processes can be carried out.

  2. Pulsed remote field eddy current technique applied to non-magnetic flat conductive plates

    Science.gov (United States)

    Yang, Binfeng; Zhang, Hui; Zhang, Chao; Zhang, Zhanbin

    2013-12-01

    Non-magnetic metal plates are widely used in aviation and industrial applications. The detection of cracks in thick plate structures, such as multilayered structures of aircraft fuselage, has been challenging in nondestructive evaluation societies. The remote field eddy current (RFEC) technique has shown advantages of deep penetration and high sensitivity to deeply buried anomalies. However, the RFEC technique is mainly used to evaluate ferromagnetic tubes. There are many problems that should be fixed before the expansion and application of this technique for the inspection of non-magnetic conductive plates. In this article, the pulsed remote field eddy current (PRFEC) technique for the detection of defects in non-magnetic conducting plates was investigated. First, the principle of the PRFEC technique was analysed, followed by the analysis of the differences between the detection of defects in ferromagnetic and non-magnetic plain structures. Three different models of the PRFEC probe were simulated using ANSYS. The location of the transition zone, defect detection sensitivity and the ability to detect defects in thick plates using three probes were analysed and compared. The simulation results showed that the probe with a ferrite core had the highest detecting ability. The conclusions derived from the simulation study were also validated by conducting experiments.

  3. Efficacy of multipolar radiofrequency with pulsed magnetic field therapy for the treatment of abdominal cellulite.

    Science.gov (United States)

    Wanitphakdeedecha, Rungsima; Sathaworawong, Angkana; Manuskiatti, Woraphong; Sadick, Neil S

    2017-08-01

    Cellulite is a metabolic condition, predominately seen in females, that affects the subcutaneous tissue of the posterolateral thighs, buttocks, pelvic region, and abdomen. It is characterized by skin dimpling and lumpiness resembling an orange peel. Despite the wide range of treatment options for patients with cellulite, there is a paucity of empirical data supporting their efficacy. The objective of this study was to evaluate the efficacy of a new-generation multipolar radiofrequency (RF) device for the treatment of cellulite. A multipolar RF device with pulsed magnetic fields was used to treat abdominal cellulite. Twenty-five healthy adult females with stage II or stage III abdominal cellulite underwent 8 weekly treatments. Assessments were performed at baseline and at weeks 1, 4, and 12 following the final treatment. Reduction in subcutaneous thickness in the axial and sagittal plane of the abdomen was observed at 1 week following treatment initiation. Results from self-reported questionnaires revealed a significantly high level of patient satisfaction (60%). Assessments by a blinded investigator at one, four, and twelve weeks after the final treatment demonstrated a significant improvement in cellulite appearance. No adverse effects were reported and the treatment was well tolerated. This study demonstrates the safety, efficacy, and subject satisfaction of multipolar RF with pulsed magnetic field therapy in the treatment of abdominal cellulite.

  4. Large field-induced irreversibility in Ni-Mn based Heusler shape-memory alloys: A pulsed magnetic field study

    Science.gov (United States)

    Nayak, A. K.; Mejia, C. Salazar; D'Souza, S. W.; Chadov, S.; Skourski, Y.; Felser, C.; Nicklas, M.

    2014-12-01

    We present a pulsed magnetic field study on the magnetic and magnetostriction properties of Ni-Mn-Z (Z =In , Sn, and Sb) based Heusler shape-memory alloys. These materials generally display a field-induced magnetostructural transition that could lead to an irreversible phase transition, when measured near the martensitic transition temperature. Here, we show that independently of the transition temperature, the critical field for the phase transition sensitively depends on the main-group element in the sample. Irrespective of their compositions, all samples display a magnetization of around 2 μB/f .u . in the martensite phase and about 6 μB/f .u . in the cubic austenite phase. Our magnetic and magnetostriction measurements at low temperatures exhibit a partial or complete arrest of the high-field austenite phase below the reverse martensitic transition. This results in a large irreversibility with a hysteresis width as high as 24 T. We introduce a theoretical model to discuss the experimental results.

  5. Human exposure from pulsed magnetic field therapy mats: a numerical case study with three commercial products.

    Science.gov (United States)

    De Santis, Valerio; Douglas, Mark; Nadakuduti, Jagadish; Benkler, Stefan; Chen, Xi Lin; Kuster, Niels

    2015-02-01

    A previous study found that incident magnetic field exposure from pulsed magnetic field therapy (PMFT) mats can exceed ICNIRP 1998 reference levels. Due to the popularity of PMFT mats for private therapeutic use, regulators need to know if the products are compliant with the basic restrictions and how overexposure can be determined. This case study's objective was to test if such products are intrinsically compliant with ICNIRP 1998 and ICNIRP 2010 basic restrictions by evaluating three different commercially-available PMFT products. In the first step, experimentally validated numerical models of these mats were developed. As a second step, the induced fields were evaluated in high-resolution anatomical models of the IT'IS Virtual Population for various lying positions and compared to the safety guidelines. As expected, a strong influence of exposure on the PMFT design, anatomy, lying position and body orientation was found. The maximum exposure of one PMFT exceeds 3.1 times the basic restrictions of ICNIRP 1998 for the central nervous system tissues and 1.36 times the limit of ICNIRP 2010 for the peripheral tissues. Body loops can significantly increase the electric fields close to the skin, e.g., when the hand and thigh are in contact during mat use. In conclusion, PMFT products are not intrinsically compliant with ICNIRP 1998 and ICNIRP 2010 basic restrictions and therefore require special considerations. © 2015 Wiley Periodicals, Inc.

  6. STRONG SOLAR WIND DYNAMIC PRESSURE PULSES: INTERPLANETARY SOURCES AND THEIR IMPACTS ON GEOSYNCHRONOUS MAGNETIC FIELDS

    Energy Technology Data Exchange (ETDEWEB)

    Zuo, Pingbing; Feng, Xueshang; Wang, Yi [SIGMA Weather Group, State Key Laboratory of Space Weather, National Space Science Center, Chinese Academy of Sciences, Beijing (China); Xie, Yanqiong [College of Meteorology and Oceanography, PLA University of Science and Technology, Nanjing (China); Xu, Xiaojun, E-mail: pbzuo@spaceweather.ac.cn, E-mail: fengx@spaceweather.ac.cn [Space Science Institute, Macau University of Science and Technology, Macao (China)

    2015-10-20

    In this investigation, we first present a statistical result of the interplanetary sources of very strong solar wind dynamic pressure pulses (DPPs) detected by WIND during solar cycle 23. It is found that the vast majority of strong DPPs reside within solar wind disturbances. Although the variabilities of geosynchronous magnetic fields (GMFs) due to the impact of positive DPPs have been well established, there appears to be no systematic investigations on the response of GMFs to negative DPPs. Here, we study both the decompression effects of very strong negative DPPs and the compression from strong positive DPPs on GMFs at different magnetic local time sectors. In response to the decompression of strong negative DPPs, GMFs on the dayside near dawn and near dusk on the nightside, are generally depressed. But near the midnight region, the responses of GMF are very diverse, being either positive or negative. For part of the events when GOES is located at the midnight sector, the GMF is found to abnormally increase as the result of magnetospheric decompression caused by negative DPPs. It is known that under certain conditions magnetic depression of nightside GMFs can be caused by the impact of positive DPPs. Here, we find that a stronger pressure enhancement may have a higher probability of producing the exceptional depression of GMF at the midnight region. Statistically, both the decompression effect of strong negative DPPs and the compression effect of strong positive DPPs depend on the magnetic local time, which are stronger at the noon sector.

  7. Control and manipulation of quantum spin switching and spin correlations in [Tb2] molecular magnet under a pulse magnetic field

    Science.gov (United States)

    Farberovich, Oleg V.; Bazhanov, Dmitry I.

    2017-10-01

    A general study of [Tb2] molecular magnet is presented using the general spin Hamiltonian formalism. A spin-spin correlators determined for a spin wave functions in [Tb2] are analyzed numerically and compared in details with the results obtained by means of conventional quantum mechanics. It is shown that the various expectation values of the spin operators and a study of their corresponding probability distributions allow to have a novel understanding in spin dynamics of entangled qubits in quantum [Tb2] system. The obtained results reveal that the properties of spin-spin correlators are responsible for the entanglement of the spin qubit under a pulse magnetic field. It allows us to present some quantum circuits determined for quantum computing within SSNQ based on [Tb2] molecule, including the CNOT and SWAP gates.

  8. Reducing Viscosity of Liquid Suspensions by pulsed electric or magnetic field

    Science.gov (United States)

    Tao, R.

    2007-03-01

    Viscosity of liquid suspensions is of great importance. Controlling the viscosity is vital in science and engineering. In electrorheological (ER) or magentorheological (MR) fluids, electric or magnetic field is used to increase the viscosity. However, in most cases we need to lower the viscosity. For example, reducing blood's viscosity improves circulation and prevents cardiovascular events. Lowering the viscosity of crude oil is the key to transporting offshore oil via undersea pipelines. Unfortunately, to date there are no effective methods for reducing the viscosity except by changing the temperature. In case that changing temperature is not an option, such as in the above examples, reducing the viscosity becomes formidable. Here we present a theory and experimental results showing that application of a suitable electric or magnetic field pulse can significantly reduce the viscosity of liquid suspensions for several hours with no change of temperature. The field induces dipolar interactions between the suspended particles and forces them to aggregate into large particles. The aggregation changes the rheological properties of the fluids and reduces the effective viscosity. Positive experimental results with MR fluids and crude oil indicate that this method, developed from the basic mechanism of viscosity, is universal and powerful for all liquid suspensions with broad applications.

  9. Proximity detector circuits: an attractive alternative to tunnel diode oscillators for contactless measurements in pulsed magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Altarawneh, Moaz M [Los Alamos National Laboratory; Mielke, Charles H [Los Alamos National Laboratory

    2009-01-01

    A new radio frequency oscillator circuit based on a proximity detector integrated circuit is described as an alternative for the traditional tunnel diode oscillator used for pulsed magnetic field measurements at low temperatures. The new circuit has been successfully applied to measure the superconducting upper critical field in Ba{sub 0.55}K{sub 0.45}Fe{sub 2}As{sub 2} single crystfl.ls up to 60 T. The new circuit design avoids many of the problems associated with tunnel diode circuits while keeping the advantages of contact less measurements in pulsed magnets.

  10. Small plastic piston-cylinder cell for pulsed magnetic field studies at cryogenic temperatures

    Science.gov (United States)

    Coniglio, William A.; Graf, David E.; Tozer, Stanley W.

    2013-06-01

    A plastic piston-cylinder cell based on a thick wall test-tube has been designed for pulsed magnetic field studies. The small 12.7 mm diameter and overall height of 19.3 mm allow the cell to freely rotate in a cryostat with a diameter of 21.5 mm. Electrical leads, coax cable or microstrip transmission lines can be introduced into the pressure chamber for a variety of measurements such as electrical transport, de Haas-van Alphen, Shubnikov-de Haas and Hall effect. A fiber optic has been introduced for the purpose of calibrating the pressure via a ruby manometer. The fiber optic opens up additional experimental techniques such as photoluminescence, photoconductivity and, with use of a special fiber with a Bragg grating, magnetostriction and thermal expansion. Maximum pressures of 0.35 GPa at room temperature have been obtained.

  11. A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies.

    Science.gov (United States)

    Islam, Zahirul; Ruff, Jacob P C; Nojiri, Hiroyuki; Matsuda, Yasuhiro H; Ross, Kathryn A; Gaulin, Bruce D; Qu, Zhe; Lang, Jonathan C

    2009-11-01

    We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields (approximately 1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

  12. Ultrafast quantum spin-state switching in the Co-octaethylporphyrin molecular magnet with a terahertz pulsed magnetic field

    Science.gov (United States)

    Farberovich, Oleg V.; Mazalova, Victoria L.

    2016-05-01

    Molecular spin crossover switches are the objects of intense theoretical and experimental studies in recent years. This interest is due to the fact that these systems allow one to control their spin state by applying an external photo-, thermo-, piezo-, or magnetic stimuli. The greatest amount of research is currently devoted to the study of the effect of the photoexcitation on the bi-stable states of spin crossover single molecular magnets (SMMs). The main limitation of photo-induced bi-stable states is their short lifetime. In this paper we present the results of a study of the spin dynamics of the Co-octaethylporphyrin (CoOEP) molecule in the Low Spin (LS) state and the High Spin (HS) state induced by applying the magnetic pulse of 36.8 T. We show that the spin switching in case of the HS state of the CoOEP molecule is characterized by a long lifetime and is dependent on the magnitude and duration of the applied field. Thus, after applying an external stimuli the system in the LS state after the spin switching reverts to its ground state, whereas the system in the HS state remains in the excited state for a long time. We found that the temperature dependency of magnetic susceptibility shows an abrupt thermal spin transition between two spin states at 40 K. Here the proposed theoretical approach opens the way to create modern devices for spintronics with the controllable spin switching process.

  13. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

    Science.gov (United States)

    Zevenhoven, Koos C. J.; Dong, Hui; Ilmoniemi, Risto J.; Clarke, John

    2015-01-01

    Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents.

  14. Pre-earthquake Magnetic Pulses

    CERN Document Server

    Scoville, John; Freund, Friedemann

    2014-01-01

    A semiconductor model of rocks is shown to describe unipolar magnetic pulses, a phenomenon that has been observed prior to earthquakes. These pulses are observable because their extremely long wavelength allows them to pass through the Earth's crust. Interestingly, the source of these pulses may be triangulated to pinpoint locations where stress is building deep within the crust. We couple a semiconductor drift-diffusion model to a magnetic field in order to describe the electromagnetic effects associated with electrical currents flowing within rocks. The resulting system of equations is solved numerically and it is seen that a volume of rock may act as a diode that produces transient currents when it switches bias. These unidirectional currents are expected to produce transient unipolar magnetic pulses similar in form, amplitude, and duration to those observed before earthquakes, and this suggests that the pulses could be the result of geophysical semiconductor processes.

  15. Three-dimensional extremely-short optical pulses in carbon nanotube arrays in the presence of an external magnetic field

    Science.gov (United States)

    Zhukov, Alexander V.; Bouffanais, Roland; Belonenko, Mikhail B.; Galkina, Elena N.

    2016-12-01

    In this paper, we study the behavior of three-dimensional extremely-short optical pulses propagating in a system made of carbon nanotubes in the presence of an external magnetic field applied perpendicular both to the nanotube axis and to the direction of propagation of the pulse. The evolution of the electromagnetic field is classically derived on the basis of the Maxwell’s equations. The electronic system of carbon nanotubes is considered in the low-temperature approximation. Our analysis reveals the novel and unique ability of controlling the shape of propagating short optical pulses by tuning the intensity of the applied magnetic field. This effect paves the way for the possible development of innovative applications in optoelectronics.

  16. Double-Pulse Spectra and Closed-Orbits: Photodetachment of H-in Parallel Electric and Magnetic Fields

    Institute of Scientific and Technical Information of China (English)

    DU Meng-Li

    2003-01-01

    We derive a formula for double-pulse spectra from closed-orbit theory. We then calculate the double-pulsephotodetachment spectra of H- in the presence of parallel electric and magnetic fields. We analyze the spectra in termsof closed-orbits of the system. We suggest a method for the measurement of a phase associated with each closed-orbit.

  17. Microwave absorption in the singlet paramagnet HoVO 4 in high pulsed magnetic fields up to 40 T

    Science.gov (United States)

    Goiran, M.; Klingeler, R.; Kazei, Z. A.; Snegirev, V. V.

    2007-11-01

    Microwave absorption of the rare-earth (RE) oxide compound HoVO 4 (tetragonal-zircon structure) is investigated in pulsed magnetic fields up to 40 T in the low-temperature range. For a magnetic field along the tetragonal crystal axis a few resonance absorption lines are observed at the wavelengths 871, 406 and 305 μm corresponding to electron transitions from the ground and low-lying energy levels of the Ho 3+ ion. In addition, broad non-resonance absorption is observed at 871 and 406 μm in fields up to 15 T. The positions and intensities of the observed resonance lines are described quite well within the crystal field formalism with the known crystal field parameters. The effects of the small orthorhombic component of the crystal field, magnetic field misorientation out the symmetry axis and various pair interactions on the absorption spectra in HoVO 4 are analyzed and discussed.

  18. Experimental studies on ultralow frequency pulsed gradient magnetic field inducing apoptosis of cancer cell and inhibiting growth of cancer cell

    Institute of Scientific and Technical Information of China (English)

    曾繁清; 郑从义; 张新晨; 李宗山; 李朝阳; 王川婴; 张新松; 黄晓玲; 张沪生

    2002-01-01

    The morphology characteristics of cell apoptosis of the malignant tumour cells in magnetic field-treated mouse was observed for the first time. The apoptotic cancer cell contracted, became rounder and divorced from adjacent cells; the heterochromatin condensed and coagulated together along the inner side of the nuclear membrane; the endoplasmic reticulums(ER) expanded and fused with the cellular membrane; many apoptotic bodies which were packed by the cellular membrane appeared and were devoured by some lymphocytes and plasma. Apoptosis of cancer cells was detected by terminal deoxynucleotidyl transferase mediated in situ nick end labeling(TUNEL). It was found that the number of apoptosis cancer cells of the sample treated by the magnetic field is more than that of the control sample. The growth of malignant tumour in mice was inhibited and the ability of immune cell to dissolve cancer cells was improved by ultralow frequency(ULF) pulsed gradient magnetic field; the nuclei DNA contents decreased, indicating that magnetic field can block DNA replication and inhibit mitosis of cancer cells. It was suggested that magnetic field could inhibit the metabolism of cancer cell, lower its malignancy, and restrain its rapid and heteromorphic growth. Since ULF pulsed gradient magnetic field can induce apoptosis of cancer cells and inhibit the growth of malignant tumour, it could be used as a new method to treat cancer.

  19. The break of shielding current at pulsed field magnetization of a superconducting annulus (experiment and model simulation)

    Science.gov (United States)

    Korotkov, V. S.; Krasnoperov, E. P.; Kartamyshev, A. A.

    2017-09-01

    During the pulsed field magnetization of a high-T c annulus in liquid nitrogen the shielding current drops abruptly, providing rapid penetration of the magnetic flux into the hole of the superconductor. After the break of current the trapped field in the hole is small and negative although the body of the annulus remains highly magnetized. In the present work the current breaking effect is investigated both experimentally and numerically. The influence of the pulse parameter on the shielding current evolution during the break is researched. A simple model for the qualitative description of this process is proposed. The model shows the development of heating localized on the inhomogeneity of the high-temperature superconductor annulus providing the formation of a high resistive channel with temperature near to T c. The appearance of this hot channel leads to the rapid reduction of the shielding current and presents a new scenario of flux jump at high temperature.

  20. Empirical compensation function for eddy current effects in pulsed field gradient nuclear magnetic resonance experiments.

    Science.gov (United States)

    Zhu, X X; Macdonald, P M

    1995-05-01

    An empirical compensation function for the correction of eddy current effects in the Stejskal-Tanner pulsed-gradient spin-echo (PGSE) nuclear magnetic resonance (NMR) experiments has been established. Eddy currents may arise as a result of the application of sharp and strong gradient pulses and may cause severe distortion of the NMR signals. In this method, the length of one gradient pulse is altered to compensate for the eddy current effects. The compensation is considered to be ideal when the position and the phase of the spin-echo maximum obtained from an aqueous solution of poly(ethylene glycol) (PEG) is the same in the presence and absence of a gradient pulse in the PGSE pulse sequence. We first characterized the functional dependence of the length of the required compensation on the three principal variables in the PGSE experiment: the gradient strength, the duration of the gradient pulse, and the interval between the two gradient pulses. Subsequently, we derived a model which successfully describes the general relationship between these variables and the size of the induced eddy current. The parameters extracted from fitting the model to the experimental compensation data may be used to predict the correct compensation for any combination of the three principal variables.

  1. Pulsed Field Gradient Nuclear Magnetic Resonance and Applications in Yttrium Type Zeolites

    Science.gov (United States)

    Wu, Shaoxiong

    Molecular self-diffusion measurements by Pulsed Field Gradient Nuclear Magnetic Resonance (PFG NMR) spectroscopy can be applied to numerous fields. PFG NMR spectroscopy usually requires no special labeling for measuring hydrocarbon self-diffusion in a variety of samples. This is a significant advantage over using radioactive isotopes or photolabeled molecules since no special sample preparation or handling is required. A single set of experiments can yield diffusion coefficients and often can be performed in a few hours. The range of diffusion coefficients (10^{ -4} cm^2/s-10 ^{-10} cm^2/s) which can be determined by PFG NMR covers most ranges of molecular diffusion. This work describes the design of a PFG NMR spectrometer for measuring hydrocarbon self-diffusion in zeolites. The principles of PFG NMR spectroscopy are illustrated. A pulsed field gradient 60 MHz NMR spectrometer was constructed. Diffusion data were acquired by PFG NMR for standard samples of water, ammonia and glycerol and are in good agreement with those reported in the literature. Following verification of spectrometer performance, the self-diffusion coefficients of isobutane in cation exchanged Y type zeolites were determined. The results show that the mobility of molecules in zeolites depends on the nature of the cations. For small crystallite zeolites, intercrystalline and intracrystalline diffusion has been observed. The effective diffusion coefficients strongly depend on the concentration of adsorbate as well as the packing method. Large discrepancies between diffusion coefficients in zeolites measured by PFG NMR and by adsorption rate experiments have been reported. Surface area, crystallite size, percentage of water in the zeolite, percentage of cation exchanged into the zeolite and other physical chemical properties effect hydrocarbon diffusivity. Detailed methods for determining these properties are discussed. As an extended study of zeolite catalysts, the adsorption of ethylene on

  2. Pulsed magnetic field: a contemporary approach offers to enhance plant growth and yield of soybean.

    Science.gov (United States)

    Radhakrishnan, Ramalingam; Ranjitha Kumari, Bollipo Diana

    2012-02-01

    The possible involvement of pulsed magnetic field (PMF) pretreatment in development and yield of soybean was investigated. Seeds were subjected to 20 days with 1500 nT at 10.0 Hz of PMF for 5 h per day. PMF pretreatment increased the plant height, fresh and dry weight, and protein content with the changes of protein profile in 8 days old seedlings. In addition, activity of enzymes such as β-amylase, acid phosphatase, polyphenol oxidase and catalase was enhanced while α-amylase, alkaline phosphatase, protease and nitrate reductase activities declined due to PMF exposure. However, a considerable increment of Fe, Cu, Mn, Zn, Mg, K and Na contents with reduced level of Ca was found in PMF treated seedlings. The number of leaves, pods, seeds and length of pods, and weight of seeds were also remarkably higher in PMF treatment in contrast to controls. The results suggest that pretreatment of PMF plays important roles in improvement of crop productivity of soybean through the enhancement of protein, mineral accumulation and enzyme activities which leads to increase the growth and yield.

  3. Imaging of the magnetic field structure in megagauss plasmas by combining pulsed polarimetry with an optical Kerr effect shutter technique.

    Science.gov (United States)

    Smith, R J

    2010-10-01

    Pulsed polarimetry in combination with a high speed photographic technique based on the optical Kerr effect is described. The backscatter in a pulsed polarimeter is directed through a scattering cell and photographed using an ∼1 ps shutter, essentially freezing the intensity pattern. The image provides both the local electron density and magnetic field distributions along and transverse to the laser sightline. Submillimeter spatial resolution is possible for probing wavelengths in the visible due to the high densities and strong optical activity. Pulsed polarimetry is thereby extended to centimeter-sized plasmas with n(e)>10(19)-10(20) cm(-3) and B>20-100 T (MG) produced by multiterawatt, multimega-ampere electrical drivers, wire Z pinches, and liner imploded magnetized plasmas.

  4. Note: radio frequency inductance-capacitance band-stop filter circuit to perform contactless conductivity measurements in pulsed magnetic fields.

    Science.gov (United States)

    Altarawneh, M M

    2012-09-01

    We present a new technique to perform radio frequency (rf) contactless conductivity measurements in pulsed magnetic fields to probe different ground states in condensed matter physics. The new method utilizes a simple analog band-stop filter circuit implemented in a radio frequency transmission setup to perform contactless conductivity measurements. The new method is more sensitive than the other methods (e.g., the tunnel diode oscillator and the proximity detector oscillator) due to more sensitive dependence of the circuit resonance frequency on the tank circuit inductance (not the transmission line). More important, the new method is more robust than other methods when used to perform measurements in very high magnetic fields, works for a wide range of temperatures (i.e., 300 K-1.4 K) and is less sensitive to noise and mechanical vibrations during pulse magnet operation. The new technique was successfully applied to measure the Shubnikov-de Haas effect in Bi(2)Se(3) in pulsed magnetic fields of up to 60 T.

  5. Pulsed magnetic field excitation sensitivity of match-type electric blasting caps.

    Science.gov (United States)

    Parson, Jonathan; Dickens, James; Walter, John; Neuber, Andreas A

    2010-10-01

    This paper presents a study on energy deposition and electromagnetic compatibility of match-type electroexplosive devices (EEDs), which recently have found more usage in pulsed power environments with high electromagnetic interference (EMI) background. The sensitivity of these devices makes them dangerous to intended and unintended radiation produced by devices commonly used in pulsed power environments. Match-type EEDs have been found to be susceptible to such low levels of energy (7-8 mJ) that safe operation of these EEDs is vital when in use near devices that produce high levels of pulsed EMI. The scope of this paper is to provide an investigation that incorporates results of similar studies to provide detonation characteristics of these EEDs. The three topics included in this study are sensitivity testing, modeling of the thermodynamic heat propagation, and electromagnetic compatibility from pulsed electromagnetic radiation. The thermodynamic joule heating of the primary explosive has been modeled by a solution to the 1D heat equation. A simple pulsed generator, Marx generator with an inductive load, was used for the electromagnetic compatibility assessment of the coupled field between the pulse generator and shorted EED. The results of the electromagnetic compatibility assessment relate the resistive, inductive, and capacitive components of the pulse generator to the area of the shorted EED.

  6. Occupational exposure measurements of static and pulsed gradient magnetic fields in the vicinity of MRI scanners.

    Science.gov (United States)

    Kännälä, Sami; Toivo, Tim; Alanko, Tommi; Jokela, Kari

    2009-04-07

    Recent advances in magnetic resonance imaging (MRI) have increased occupational exposure to magnetic fields. In this study, we examined the assessment of occupational exposure to gradient magnetic fields and time-varying magnetic fields generated by motion in non-homogeneous static magnetic fields of MRI scanners. These magnetic field components can be measured simultaneously with an induction coil setup that detects the time rate of change of magnetic flux density (dB/dt). The setup developed was used to measure the field components around two MRI units (1 T open and 3 T conventional). The measured values can be compared with dB/dt reference levels derived from magnetic flux density reference levels given by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The measured motion-induced dB/dt values were above the dB/dt reference levels for both MRI units. The measured values for the gradient fields (echo planar imaging (EPI) and fast field echo (FFE) sequences) also exceeded the dB/dt reference levels in positions where the medical staff may have access during interventional procedures. The highest motion-induced dB/dt values were 0.7 T s(-1) for the 1 T scanner and 3 T s(-1) for the 3 T scanner when only the static field was present. Even higher values (6.5 T s(-1)) were measured for simultaneous exposure to motion-induced and gradient fields in the vicinity of the 3 T scanner.

  7. Pulsed Magnetic Field Driven Gas Core Reactors for Space Power & Propulsion Applications

    Science.gov (United States)

    Anghaie, Samim; Smith, Blair; Knight, Travis; Butler, Carey

    2003-01-01

    The present results indicated that: 1. A pulsed magnetic driven fission power concept, PMD-GCR is developed for closed (NER) and semi-open (NTR) operations. 2. In power mode, power is generated at alpha less than 1 for power levels of hundreds of KW or higher 3. IN semi open NTR mode, PMD-GCR generates thrust at I(sub sp) approx. 5,000 s and jet power approx. 5KW/Kg. 4. PMD-GCR is highly subcritical and is actively driven to critically. 5. Parallel path with fusion R&D needs in many areas including magnet and plasma.

  8. The effect of external magnetic field on the density distributions and electromagnetic fields in the interaction of high-intensity short laser pulse with collisionless underdense plasma

    Science.gov (United States)

    Mahmoodi-Darian, Masoomeh; Ettehadi-Abari, Mehdi; Sedaghat, Mahsa

    2016-03-01

    Laser absorption in the interaction between ultra-intense femtosecond laser and solid density plasma is studied theoretically here in the intensity range I{λ^2} ˜eq 10^{14}{-}10^{16}{{W}}{{{cm}}^{-2}} \\upmu{{{m}}2} . The collisionless effect is found to be significant when the incident laser intensity is less than 10^{16}{{W}}{{{cm}}^{-2}}\\upmu{{{m}}2} . In the current work, the propagation of a high-frequency electromagnetic wave, for underdense collisionless plasma in the presence of an external magnetic field is investigated. When a constant magnetic field parallel to the laser pulse propagation direction is applied, the electrons rotate along the magnetic field lines and generate the electromagnetic part in the wake with a nonzero group velocity. Here, by considering the ponderomotive force in attendance of the external magnetic field and assuming the isothermal collisionless plasma, the nonlinear permittivity of the plasma medium is obtained and the equation of electromagnetic wave propagation in plasma is solved. Here, by considering the effect of the ponderomotive force in isothermal collisionless magnetized plasma, it is shown that by increasing the laser pulse intensity, the electrons density profile leads to steepening and the electron bunches of plasma become narrower. Moreover, it is found that the wavelength of electric and magnetic field oscillations increases by increasing the external magnetic field and the density distribution of electrons also grows in comparison to the unmagnetized collisionless plasma.

  9. Academic Training - Pulsed SC Magnets

    CERN Multimedia

    Françoise Benz

    2006-01-01

    2005-2006 ACADEMIC TRAINING PROGRAMME LECTURE SERIES 2, 3, June 29, 30, 31 May, 1, 2 June 11:00-12:00 - Auditorium, bldg 500 Pulsed SC Magnets by M. Wilson Lecture 1. Introduction to Superconducting Materials Type 1,2 and high temperature superconductors; their critical temperature, field & current density. Persistent screening currents and the critical state model. Lecture 2. Magnetization and AC Loss How screening currents cause irreversible magnetization and hysteresis loops. Field errors caused by screening currents. Flux jumping. The general formulation of ac loss in terms of magnetization. AC losses caused by screening currents. Lecture 3. Twisted Wires and Cables Filamentary composite wires and the losses caused by coupling currents between filaments, the need for twisting. Why we need cables and how the coupling currents in cables contribute more ac loss. Field errors caused by coupling currents. Lecture 4. AC Losses in Magnets, Cooling and Measurement Summary of all loss mech...

  10. Pulsed magnetic field study of the spin gap in intermediate valence compound SmB{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Flachbart, K., E-mail: flachb@saske.s [Institute of Experimental Physics, SAS, SK-04001 Kosice (Slovakia); Bartkowiak, M. [Hochfeld-Magnetlabor, FZD, D-01314 Dresden (Germany); Demishev, S. [General Physics Institute, RAS, RU-119991, Moscow (Russian Federation); Gabani, S. [Institute of Experimental Physics, SAS, SK-04001 Kosice (Slovakia); Glushkov, V. [General Physics Institute, RAS, RU-119991, Moscow (Russian Federation); Herrmannsdorfer, T. [Hochfeld-Magnetlabor, FZD, D-01314 Dresden (Germany); Moshchalkov, V. [Katholieke Universiteit Leuven, Celestijnenlaan 200 D, B-3001 Leuven (Belgium); Shitsevalova, N. [Institute for Problems of Materials Science, NASU, UA-252680 Kiev (Ukraine); Sluchanko, N. [General Physics Institute, RAS, RU-119991, Moscow (Russian Federation)

    2009-10-15

    In this work, we report the behavior of electrical resistivity of SmB{sub 6} at temperatures between 2.2 and 70 K in pulsed magnetic fields up to 54 T. A strong negative magnetoresistance was detected with increasing magnetic field, when lowering the temperature in the range T<30 K. We show that the amplitude of negative magnetoresistance reaches its maximum dR/Rapprox70% at B=54 T, in the vicinity of phase transition occurring in this strongly correlated electron system at T{sub C}approx5 K. The crossover from negative magnetoresistance to positive magnetoresistance found at intermediate temperatures at T>30 K is discussed within the framework of exciton-polaron model of local charge fluctuations in SmB{sub 6} proposed by Kikoin and Mishchenko. It seems that these exciton-polaron in-gap states are influenced both by temperature and magnetic field.

  11. Effect of extremely weak pulsed magnetic field type Bemer 3000 on ratings of perceived exertion

    Directory of Open Access Journals (Sweden)

    D Gazurek

    2008-06-01

    Full Text Available The aim of this study was to examine whether is an influence of the exposition on different inductions of magnetic fields on rating of perceived exertion during 10 min long standardised physical cycloergometer exercise. The investigation was performed in 40 healthy, non-smoking, fit men, mean age 202. The participants were randomly attributed to 4 groups, each including 10 subjects. The first one (group E18 consisted of subjects exposed to the magnetic field with the intensity of 18 μT, the second one (group E64 exposed to the magnetic field with the intensity of 64 μT. Two control groups were formed to accompany these exposed to the magnetic field. In these placebo groups (S-T subjects were not exposed to the magnetic field (so called false therapy, „sham treatment”. The study consisted of 4 steps: pilot study, the first endurance test, exposure to the magnetic field, the second endurance test. The aim of the pilot study was to define subjective feelings of the participant during the effort, his reaction to the effort and also practical familiarization with the character and rules of the endurance test and Borg scale interpretation during 10 min of endurance cycloergometer test. The first endurance test was performed two days after the pilot study with the same rules and its goal was to measure the level of tiredness according to the Borg scale during 10 min long standardised physical effort. The second endurance test was performed according to the same rules as the first one and its goal was to analyse the effect of 20 exposures to the magnetic field with the intensity of 18 and 64 μT repeated daily on the perception of tiredness increase as expressed in the Borg scale when performing 10 min long standardised physical effort. In subjects exposed to 18 μT magnetic field neither changes in the perception of fatigue nor changes in the heart rate at particular levels of the Borg scale have been observed. When compared with both control

  12. Pulsed magnetic field from video display terminals enhances teratogenic effects of cytosine arabinoside in mice

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, H.; Wu, R.Y.; Shao, B.J.; Fu, Y.D.; Yao, G.D.; Lu, D.J. [Zhejiang Medical Univ. (China)

    1995-05-01

    Eighty-nine Swiss Webster mice were randomly divided into four groups: a control group, a pulsed magnetic field (PMF) group, a cytosine arabinoside (ara-C, a teratogen) group, and a combined PMF + ara-C group. Mice in the PMF and PMF + ara-C groups were irradiated with a PMF (a sawtooth waveform with 52 {mu}s rise time, 12{mu}s decay time, and 15.6 kHz frequency) at a peak magnetic flux density of 40 {mu}T for 4 hours daily on days 6-17 of gestation. The mice in the ara-C and the PMF + ara-C groups were injected intraperitoneally on day 9 of gestation with 10 mg/kg of ara-C. The incidence of resorption and dead fetuses was not affected by PMF but was increased by ara-C injection. The malformation incidence of cleft palate (CP) and/or cleft lip (CL) was significantly higher in all three of the treated groups than in the control group (P < 0.05). If, however, statistical analyses had been done on litters rather than on individual fetuses, they would show that the incidence of CP and/or CL in the PMF group is not significantly greater than that in the control group. A significantly higher incidence of CP and/or CL was found in the PMF + ara-C group (49%) than the ara-C alone group (26.1%). These data suggest that PMF might enhance the development of ara-C-induced CP and/or CL. The incidence of minor variations in skeletal development, including reduction of skeletal calcification and loss of skeleton, was not statistically significant in the PMF group. However, it was higher in the two ara-C-treated groups, and there was no significant difference between the ara-C alone group and the ara-C + PMF group. From these results it is concluded that the very weak embryotoxic effects of PMF exposure may be revealed and enhanced in combination with a teratogenic agent.

  13. Membrane permeabilization of mammalian cells using bursts of high magnetic field pulses

    Directory of Open Access Journals (Sweden)

    Vitalij Novickij

    2017-04-01

    Full Text Available Background Cell membrane permeabilization by pulsed electromagnetic fields (PEMF is a novel contactless method which results in effects similar to conventional electroporation. The non-invasiveness of the methodology, independence from the biological object homogeneity and electrical conductance introduce high flexibility and potential applicability of the PEMF in biomedicine, food processing, and biotechnology. The inferior effectiveness of the PEMF permeabilization compared to standard electroporation and the lack of clear description of the induced transmembrane transport are currently of major concern. Methods The PEMF permeabilization experiments have been performed using a 5.5 T, 1.2 J pulse generator with a multilayer inductor as an applicator. We investigated the feasibility to increase membrane permeability of Chinese Hamster Ovary (CHO cells using short microsecond (15 µs pulse bursts (100 or 200 pulses at low frequency (1 Hz and high dB/dt (>106 T/s. The effectiveness of the treatment was evaluated by fluorescence microscopy and flow cytometry using two different fluorescent dyes: propidium iodide (PI and YO-PRO®-1 (YP. The results were compared to conventional electroporation (single pulse, 1.2 kV/cm, 100 µs, i.e., positive control. Results The proposed PEMF protocols (both for 100 and 200 pulses resulted in increased number of permeable cells (70 ± 11% for PI and 67 ± 9% for YP. Both cell permeabilization assays also showed a significant (8 ± 2% for PI and 35 ± 14% for YP increase in fluorescence intensity indicating membrane permeabilization. The survival was not affected. Discussion The obtained results demonstrate the potential of PEMF as a contactless treatment for achieving reversible permeabilization of biological cells. Similar to electroporation, the PEMF permeabilization efficacy is influenced by pulse parameters in a dose-dependent manner.

  14. Superconducting pulsed magnets

    CERN Document Server

    CERN. Geneva

    2006-01-01

    Lecture 1. Introduction to Superconducting Materials Type 1,2 and high temperature superconductors; their critical temperature, field & current density. Persistent screening currents and the critical state model. Lecture 2. Magnetization and AC Loss How screening currents cause irreversible magnetization and hysteresis loops. Field errors caused by screening currents. Flux jumping. The general formulation of ac loss in terms of magnetization. AC losses caused by screening currents. Lecture 3. Twisted Wires and Cables Filamentary composite wires and the losses caused by coupling currents between filaments, the need for twisting. Why we need cables and how the coupling currents in cables contribute more ac loss. Field errors caused by coupling currents. Lecture 4. AC Losses in Magnets, Cooling and Measurement Summary of all loss mechanisms and calculation of total losses in the magnet. The need for cooling to minimize temperature rise in a magnet. Measuring ac losses in wires and in magnets. Lecture 5. Stab...

  15. Slowing light down by low magnetic fields: pulse delay by transient spectral hole-burning in ruby.

    Science.gov (United States)

    Riesen, Hans; Rebane, Aleksander K; Szabo, Alex; Carceller, Ivana

    2012-08-13

    We report on the observation of slow light induced by transient spectral hole-burning in a solid, that is based on excited-state population storage. Experiments were conducted in the R1-line (2E←4A2 transition) of a 2.3 mm thick pink ruby (Al2O3:Cr(III) 130 ppm). Importantly, the pulse delay can be controlled by the application of a low external magnetic field B||c≤9 mT and delays of up to 11 ns with minimal pulse distortion are observed for ~55 ns Gaussian pulses. The delay corresponds to a group velocity value of ~c/1400. The experiment is very well modelled by linear spectral filter theory and the results indicate the possibility of using transient hole-burning based slow light experiments as a spectroscopic technique.

  16. Dietary protein and fat emulsions, processed by ultrasound and pulsed magnetic field

    Directory of Open Access Journals (Sweden)

    E. I. Verboloz

    2017-01-01

    Full Text Available For the baking of baked goods in order to save fats, different types of endorsement and protein-fatty emulsions which are used as ingredients in goods and for the protection of metal moulds from burning. Usually emulsion is prepared on bakery enterprises by National State Standard Р 51785–2001, involving mechanical beating up of ingredients. The authors suggested and studied the way of manufacturing of more stable food protein-fatty emulsions using ultrasonic transmitter with rigid neodymium magnets on its thickener. As ingredients, there were applied curd whey diluted with water, unpurified sunflower oil and sunflower phosphatides. Ratio of whey and water is 1:7. Physical effects of ultrasound and field of magnets in contact layer of liquid ingredients being dispersed have increased the viscosity and dispersion of protein-fatty emulsions. Hypothesis of increase of stability and sterility of protein-fatty emulsion by the selection of parameters of magnetic field and power of ultrasound transmitter is confirmed experimentally. Microscopic analysis shows high degree of homogeneity of emulsion under the time of processing 3-4 minutes and intensity of ultrasound 2 W/cm2, that is energetically profitable. There was revealed synergism of influence of physical effects of ultrasound and magnetic field on the durability and steadiness of emulsion to mechanical and temperature effect and also cidal effect, prolonging terms of product using. Manufacture of emulsions by the declared way using the ultrasound and magnetic field of constant neodymium magnets decreases number of injected elements-emulsifiers by 3-4 times or excludes their use at all. Existing piezoelectric ultrasound units as well as neodymium magnets have small sizes and low energy consumption, easily built into the line of continuous manufacture of emulsion for the bread production. Such emulsions are less demanding to the storage and transportation.

  17. INFLUENCE OF PULSED MAGNETIC FIELD ON MICROSTRUC- TURES AND MACRO-SEGREGATION IN 2124 Al-ALLOY

    Institute of Scientific and Technical Information of China (English)

    C. Y. Ban; J.Z. Cui; Q.X. Ba; G.M. Lu; B.J. Zhang

    2002-01-01

    The structures and macro-segregation of 2124 Al-alloy were studied when a pulsedmagnetic field (PMF) was applied during solidification. It is found through experi-ments that a remarkable change occurs in the solidification structures of 2124 Al-alloyunder pulsed magnetic field. The eutectic phase at grain boundaries change from thickcontinuous eutectic network to thin discontinuous one, and the distribution of soluteelements was also homogenized. The typical negative segregation phenomenon of Cu incommon solidification condition was restrained, and the segregation of Mg decreased.

  18. Analysis on background magnetic field to generate eddy current by pulsed gradient of permanent-magnet MRI

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In this paper the analytical expressions for the magnetic field H and induction B in iron-pole plates generated by MRI gradient coil are given using line-current and the multilayer dielectric plate model with the mirror-image method.Eddy current emanates from the magnetic flux in the iron-pole plates.In order to fully suppress the eddy current,this magnetic flux should be fully eliminated.The research results indicate the magnetic permeability of the resist-eddy plate must be bigger than that of magnetic pole material,i.e.pure iron,and that the resist-eddy plate should be thick enough to be far away from its magnetic saturation.

  19. Pre-earthquake magnetic pulses

    Directory of Open Access Journals (Sweden)

    J. Scoville

    2014-12-01

    Full Text Available A semiconductor model of rocks is shown to describe unipolar magnetic pulses, a phenomenon that has been observed prior to earthquakes. These pulses are generated deep in the Earth's crust, in and around the Hypocentral volume, days or even weeks before Earthquakes. They are observable at the surface because their extremely long wavelength allows them to pass through kilometers of rock. Interestingly, the source of these pulses may be triangulated to pinpoint locations where stresses are building deep within the crust. We couple a semiconductor drift-diffusion model to a magnetic field in order to describe the electromagnetic effects associated with electrical currents flowing within rocks. The resulting system of equations is solved numerically and it is seen that a volume of rock may act as a diode that produces transient currents when it switches bias. These unidirectional currents are expected to produce transient unipolar magnetic pulses similar in form, amplitude, and duration to those observed before earthquakes, and this suggests that the pulses could be the result of geophysical semiconductor processes.

  20. Magnetic Field

    DEFF Research Database (Denmark)

    Olsen, Nils

    2015-01-01

    of the fluid flow at the top of the core. However, what is measured at or near the surface of the Earth is the superposition of the core field and fields caused by magnetized rocks in the Earth’s crust, by electric currents flowing in the ionosphere, magnetosphere, and oceans, and by currents induced......he Earth has a large and complicated magnetic field, the major part of which is produced by a self-sustaining dynamo operating in the fluid outer core. Magnetic field observations provide one of the few tools for remote sensing the Earth’s deep interior, especially regarding the dynamics...... in the Earth by time-varying external fields. These sources have their specific characteristics in terms of spatial and temporal variations, and their proper separation, based on magnetic measurements, is a major challenge. Such a separation is a prerequisite for remote sensing by means of magnetic field...

  1. Soft magnetic properties of amorphous Fe52Co34Hf7B6Cu1 alloy treated by pulsed magnetic field and annealing

    Institute of Scientific and Technical Information of China (English)

    Gu Yue; Chao Yue-Sheng; Zhang Yan-Hui

    2012-01-01

    The crystallization,microstructure,and soft magnetic properties of Fe52Co34Hf7B6Cu1 alloy are studied.Amorphous Fe52Co34Hf7B6Cu1 alloys are first treated by a pulsed magnetic field with a medium frequency,and then annealed at 100 ℃-400 ℃ for 30 min in a vacuum.The rise in temperature during the treatment by a pulsed magnetic field is measured by a non-contact infrared thermometer.The soft magnetic properties of specimens are measured by a vibrating sample magnetometer (VSM).The microstructure changes of specimens are observed by a M(o)ssbauer spectroscopy and transmission electron microscope (TEM).The results show the medium-frequency pulsating magnetic field will promote nanocrystallization of the amorphous alloy with a lower temperature rise.The nanocrystalline phase is α-Fe(Co)with bcc crystal structure,and the grain size is about 10 nm.After vacuum annealing at 100 ℃ for 30 min,scattering nanocrystalline phases become more uniform,the coercive force and the saturation magnetization of the specimens are 41.98 A/m and 185.15 emu/g.

  2. After-pulsing, cross-talk, dark-count, and gain of MPPC under 7-T static magnetic field.

    Science.gov (United States)

    Hirano, Yoshiyuki; Nishikido, Fumihiko; Kokuryo, Daisuke; Yamaya, Taiga

    2016-07-01

    Multi-pixel photon counters (MPPCs) have been used instead of photomultiplier tubes for positron emission tomography combined with magnetic resonance (PET-MR). However, the effects of the magnetic field (MF) on the intrinsic properties-gain, cross-talk, after-pulsing, and dark-count-have not been sufficiently investigated. Therefore, we measured these properties for two types of MPPCs-S10931-50P and S12572-50P-in a static 7-T MF. These properties were measured with a pulse-shape analysis using pulse data acquired by a digital oscilloscope in the presence of the MF (w/MF) and the absence of the MF (w/o MF) by changing the supplied over-voltages (from 0.95 to 2.1 V for S10931 and from 2.1 to 3.3 V for S12572). No significant differences between the w/MF and w/o MF cases were observed for either MPPC, suggesting that the gain, cross-talk, after-pulsing, and dark-count are insensitive to a 7-T MF. The present work shows that constant MPPC performance is expected under a strong MF and demonstrates positive results for PET-MR.

  3. Measurement system for SSRF pulsed magnets

    Institute of Scientific and Technical Information of China (English)

    PENG Chengcheng; GU Ming; LIU Bo; OUYANG Lianhua

    2007-01-01

    This paper describes the magnetic field measurement system for pulsed magnets in SSRF.The system consists of magnetic probes,analog active integrator,oscilloscope,stepper motor and a controller.An application program based on LabVIEW has been developed as main control unit.After the magnetic field mapping of a septum magnet prototype,it is verified that the test results accord with the results of theoretical calculation and computer simuladon.

  4. Capture and Transport of Laser Accelerated Protons by Pulsed Magnetic Fields: Advancements Toward Laser-Based Proton Therapy

    Science.gov (United States)

    Burris-Mog, Trevor J.

    The interaction of intense laser light (I > 10 18 W/cm2) with a thin target foil leads to the Target Normal Sheath Acceleration mechanism (TNSA). TNSA is responsible for the generation of high current, ultra-low emittance proton beams, which may allow for the development of a compact and cost effective proton therapy system for the treatment of cancer. Before this application can be realized, control is needed over the large divergence and the 100% kinetic energy spread that are characteristic of TNSA proton beams. The work presented here demonstrates control over the divergence and energy spread using strong magnetic fields generated by a pulse power solenoid. The solenoidal field results in a parallel proton beam with a kinetic energy spread DeltaE/E = 10%. Assuming that next generation lasers will be able to operate at 10 Hz, the 10% spread in the kinetic energy along with the 23% capture efficiency of the solenoid yield enough protons per laser pulse to, for the first time, consider applications in Radiation Oncology. Current lasers can generate proton beams with kinetic energies up to 67.5 MeV, but for therapy applications, the proton kinetic energy must reach 250 MeV. Since the maximum kinetic energy Emax of the proton scales with laser light intensity as Emax ∝ I0.5, next generation lasers may very well accelerate 250 MeV protons. As the kinetic energy of the protons is increased, the magnetic field strength of the solenoid will need to increase. The scaling of the magnetic field B with the kinetic energy of the protons follows B ∝ E1/2. Therefor, the field strength of the solenoid presented in this work will need to be increased by a factor of 2.4 in order to accommodate 250 MeV protons. This scaling factor seems reasonable, even with present technology. This work not only demonstrates control over beam divergence and energy spread, it also allows for us to now perform feasibility studies to further research what a laser-based proton therapy system

  5. Unusual Pulsed X-Ray Emission from the Young, High Magnetic Field Pulsar PSR J1119--6127

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, M E; Kaspi, V M; Camilo, F; Gaensler, B M; Pivovaroff, M J

    2005-08-05

    We present XMM-Newton observations of the radio pulsar PSR J1119-6127, which has an inferred age of 1,700 yr and surface dipole magnetic field strength of 4.1 x 10{sup 13} G. We report the first detection of pulsed X-ray emission from PSR J1119-6127. In the 0.5-2.0 keV range, the pulse profile shows a narrow peak with a very high pulsed fraction of (74 {+-} 14)%. In the 2.0-10.0 keV range, the upper limit for the pulsed fraction is 28% (99% confidence). The pulsed emission is well described by a thermal blackbody model with a temperature of T{infinity} = 2.4{sub -0.2}{sup +0.3} x 10{sup 6} K and emitting radius of 3.4{sub -0.3}{sup +1.8} km (at a distance of 8.4 kpc). Atmospheric models result in problematic estimates for the distance/emitting area. PSR J1119-6127 is now the radio pulsar with smallest characteristic age from which thermal X-ray emission has been detected. The combined temporal and spectral characteristics of this emission are unlike those of other radio pulsars detected at X-ray energies and challenge current models of thermal emission from neutron stars.

  6. Transition from interpulse to afterglow plasmas driven by repetitive short-pulse microwaves in a multicusp magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Shail; Sahu, Debaprasad; Bhattacharjee, Sudeep [Department of Physics, Indian Institute of Technology, Kanpur 208016 (India)

    2012-08-15

    In the power-off phase, plasmas generated by repetitive short-pulse microwaves in a multicusp magnetic field show a transitive nature from interpulse to afterglow as a function of pulse duration t{sub w} = 20-200 {mu}s. The ionized medium can be driven from a highly non equilibrium to an equilibrium state inside the pulses, thereby dictating the behavior of the plasma in the power-off phase. Compared to afterglows, interpulse plasmas observed for t{sub w} < 50 {mu}s are characterized by a quasi-steady-state in electron density that persists for {approx} 20-40 {mu}s even after the end of the pulse and has a relatively slower decay rate ({approx} 4.3 Multiplication-Sign 10{sup 4} s{sup -1}) of the electron temperature, as corroborated by optical measurements. The associated electron energy probability function indicates depletion in low energy electrons which appear at higher energies just after the end of the pulse. The transition occurs at t{sub w} {approx} 50 {mu}s as confirmed by time evolution of integrated electron numbers densities obtained from the distribution function.

  7. Transition from interpulse to afterglow plasmas driven by repetitive short-pulse microwaves in a multicusp magnetic field

    Science.gov (United States)

    Pandey, Shail; Sahu, Debaprasad; Bhattacharjee, Sudeep

    2012-08-01

    In the power-off phase, plasmas generated by repetitive short-pulse microwaves in a multicusp magnetic field show a transitive nature from interpulse to afterglow as a function of pulse duration tw = 20-200 μs. The ionized medium can be driven from a highly non equilibrium to an equilibrium state inside the pulses, thereby dictating the behavior of the plasma in the power-off phase. Compared to afterglows, interpulse plasmas observed for tw < 50 μs are characterized by a quasi-steady-state in electron density that persists for ˜ 20-40 μs even after the end of the pulse and has a relatively slower decay rate (˜ 4.3 × 104 s-1) of the electron temperature, as corroborated by optical measurements. The associated electron energy probability function indicates depletion in low energy electrons which appear at higher energies just after the end of the pulse. The transition occurs at tw ˜ 50 μs as confirmed by time evolution of integrated electron numbers densities obtained from the distribution function.

  8. Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques

    Directory of Open Access Journals (Sweden)

    Shaffer Jean M

    2010-05-01

    Full Text Available Abstract Background The assessment of arterial stiffness is increasingly used for evaluating patients with different cardiovascular diseases as the mechanical properties of major arteries are often altered. Aortic stiffness can be noninvasively estimated by measuring pulse wave velocity (PWV. Several methods have been proposed for measuring PWV using velocity-encoded cardiovascular magnetic resonance (CMR, including transit-time (TT, flow-area (QA, and cross-correlation (XC methods. However, assessment and comparison of these techniques at high field strength has not yet been performed. In this work, the TT, QA, and XC techniques were clinically tested at 3 Tesla and compared to each other. Methods Fifty cardiovascular patients and six volunteers were scanned to acquire the necessary images. The six volunteer scans were performed twice to test inter-scan reproducibility. Patient images were analyzed using the TT, XC, and QA methods to determine PWV. Two observers analyzed the images to determine inter-observer and intra-observer variabilities. The PWV measurements by the three methods were compared to each other to test inter-method variability. To illustrate the importance of PWV using CMR, the degree of aortic stiffness was assessed using PWV and related to LV dysfunction in five patients with diastolic heart failure patients and five matched volunteers. Results The inter-observer and intra-observer variability results showed no bias between the different techniques. The TT and XC results were more reproducible than the QA; the mean (SD inter-observer/intra-observer PWV differences were -0.12(1.3/-0.04(0.4 for TT, 0.2(1.3/0.09(0.9 for XC, and 0.6(1.6/0.2(1.4 m/s for QA methods, respectively. The correlation coefficients (r for the inter-observer/intra-observer comparisons were 0.94/0.99, 0.88/0.94, and 0.83/0.92 for the TT, XC, and QA methods, respectively. The inter-scan reproducibility results showed low variability between the repeated

  9. High speed pulsed magnetic fields measurements, using the Faraday effect; Mesures de champs magnetiques pulses rapides a l'aide de l'effet Faraday

    Energy Technology Data Exchange (ETDEWEB)

    Dillet, A. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-12-01

    For these measures, the information used is the light polarization plane rotation induced by the magnetic field in a glass probe. This rotation is detected using a polarizer-analyzer couple. The detector is a photomultiplier used with high-current and pulsed light. In a distributed magnet (gap: 6 x 3 x 3 cm) magnetic fields to measure are 300 gauss, lasting 0.1 {mu}s, with rise times {<=} 35 ns, repetition rate: 1/s. An oscilloscope is used to view the magnetic field from the P.M. plate signal. The value of the field is computed from a previous static calibration. Magnetic fields from 50 to 2000 gauss (with the probe now used) can be measured to about 20 gauss {+-} 5 per cent, with a frequency range of 30 MHz. (author) [French] Pour faire de telles mesures, on utilise comme information la rotation du plan de polarisation de la lumiere provoquee par le champ magnetique dans une sonde en verre. On detecte cette rotation au moyen d'un polariseur et d'un analyseur, qui sont regles a 45 deg. pour conserver un phenomene lineaire. Le detecteur est un photomultiplicateur travaillant en fort courant en lumiere pulsee. Dans un aimant distribue d'entrefer 6 x 3 x 3 cm, on obtient des champs magnetiques a mesurer de 300 gauss, durant 0.1 {mu}s, avec des temps de montee {<=} 35 ns; au taux de 1 fois par seconde. L'observation du champ se fait sur oscilloscope a partir du signal de plaque du P.M. La valeur absolue du champ est obtenue au moyen d'un etalonnage statique prealable. On peut ainsi mesurer a 20 gauss et {+-} 5 pour cent pres environ des champs magnetiques de 50 a 2000 gauss (avec la sonde actuelle) et avec une bande passante de 30 MHz. (auteur)

  10. Influence of High Pulsed and Continuous Magnetic Fields on the Corrosion and Microstructure of Metallic Conductors

    Science.gov (United States)

    2014-03-31

    constraints that made using commercial off the shelf (COTS) electrochemical test setups difficult to use. The first setup had to be designed to fit...Simple Dittjrcr (in.) Figure 1. (left) Electrochemical test cell located within a DC electromagnet which applies a uniform magnetic field across the...prepared in the same method as that discussed above, beginning with a wet rough grind and finishing with the 0.1 micron alumina paste. After the rod

  11. The Los Alamos/Arzamas-16 collaboration of ultrahigh magnetic fields and ultrahigh energy pulsed power

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshev, V.K.; Mokhov, V.N.; Pavlovskii, A.I. [All-Russian Scientific Research Institute of Experimental Physics, Arzamas-16, Nizhni Novgorod Region (Russian Federation); Ekdahl, C.A.; Fowler, C.M.; Reinovsky, R.E.; Younger, S.M. [Los Alamos National Lab., NM (United States)

    1995-09-01

    The end of the Cold War has made possible some remarkable scientific adventures--joint research projects between scientific institutions of the United States and the Russian Federation. Perhaps most unprecedented of the new partnerships is a formal collaboration which has been established between the All-Russian Scientific Research Institute of Experimental Physics and the Los Alamos National Laboratory (LANL), the two institutes which designed the first nuclear weapons for their respective countries. In early 1992, emerging governmental policy in the US and Russia began to encourage ``lab-to-lab`` interactions between the nuclear weapons design laboratories of the two countries. Each government recognized that as nuclear weapons stockpiles and design activities were being reduced, highly qualified scientists were becoming available to use their considerable skills in fundamental scientific research of interest to both nations. VNIIEF and LANL quickly recognized a common interest in the technology and applications of magnetic flux compression, the technique for converting the chemical energy released by high-explosives into intense electrical pulses and intensely concentrated magnetic energy. This document reports on current projects of the collaboration.

  12. Generation of Helical and Axial Magnetic Fields by the Relativistic Laser Pulses in Under-dense Plasma: Three-Dimensional Particle-in-Cell Simulation

    Science.gov (United States)

    Zheng, Chun-Yang; Zhu, Shao-Ping; He, Xian-Tu

    2002-07-01

    The quasi-static magnetic fields created in the interaction of relativistic laser pulses with under-dense plasmas have been investigated by three-dimensional particle-in-cell simulation. The relativistic ponderomotive force can drive an intense electron current in the laser propagation direction, which is responsible for the generation of a helical magnetic field. The axial magnetic field results from a difference beat of wave-wave, which drives a solenoidal current. In particular, the physical significance of the kinetic model for the generation of the axial magnetic field is discussed.

  13. Improved Resistance Switching Stability in Fe-Doped ZnO Thin Films Through Pulsed Magnetic Field Annealing.

    Science.gov (United States)

    Xu, Hongtao; Wu, Changjin; Xiahou, Zhao; Jung, Ranju; Li, Ying; Liu, Chunli

    2017-12-01

    Five percent of Fe-doped ZnO (ZnO:Fe) thin films were deposited on Pt/TiO2/SiO2/Si substrates by a spin-coating method. The films were annealed without (ZnO:Fe-0T) and with a pulsed magnetic field of 4 T (ZnO:Fe-4TP) to investigate the magnetic annealing effect on the resistance switching (RS) behavior of the Pt/ZnO:Fe/Pt structures. Compared with the ZnO:Fe-0T film, the ZnO:Fe-4TP film showed improved RS performance regarding the stability of the set voltage and the resistance of the high resistance state. Transmission electron microscopy and X-ray photoelectron spectroscopy analyses revealed that the ZnO:Fe-4TP film contains more uniform grains and a higher density of oxygen vacancies, which promote the easier formation of conducting filaments along similar paths and the stability of switching parameters. These results suggest that external magnetic fields can be used to prepare magnetic oxide thin films with improved resistance switching performance for memory device applications.

  14. Pulsed electric fields

    Science.gov (United States)

    The concept of pulsed electric fields (PEF) was first proposed in 1967 to change the behavior or microorganisms. The electric field phenomenon was identified as membrane rupture theory in the 1980s. Increasing the membrane permeability led to the application of PEF assisted extraction of cellular co...

  15. Microstructure and performance of solid TC4 titanium alloy subjected to the high pulsed magnetic field treatment

    Energy Technology Data Exchange (ETDEWEB)

    Li, G.R., E-mail: liguirong@ujs.edu.cn; Li, Y.M.; Wang, F.F.; Wang, H.M.

    2015-09-25

    Highlights: • A high pulsed magnetic field was introduced to process the solid titanium alloy. • The phase transition from beta to alpha in processed alloy was discovered. • The magneto-plasticity effect was found and highlighted. • The strength and toughness of treated alloy were enhanced synchronously. - Abstract: The effect of high pulsed magnetic field with different magnetic induced intensity (B) on the microstructure and mechanical performance of solid TC4 titanium alloy was investigated. The microstructure morphology was characterized by metallographic microscope, scanning electronic microscopy and transmission electronic microscopy. The results show that the magnetic has induced the phase transformation from β to α. At 4 T the volume fraction of α phase has increased from 49% (B = 0) to 59%. Meanwhile, compared to that of original sample the dislocation density at 3 T is 4.8 times, which was the result of magneto-plasticity effect. However, the dislocation density will not always increase with B due to the dislocation pile-up effect. The mechanical properties tests show that the strength of materials is enhanced with the B increase within a certain scope. The strength and elongation of processed TC4 alloy exhibit the obvious changes: when B = 3 T the maximum strength reaches 1330 MPa which ascribes to the dislocation strengthening. It is enhanced by 7.6% compared to that of original sample. It is noted that when B = 4 T the strength and toughness are improved simultaneously which are attributed to not only the dislocation strengthening but also the amount, distribution and morphology of α phase.

  16. Designing an optimum pulsed magnetic field by a resistance/self-inductance/capacitance discharge system and alignment of carbon nanotubes embedded in polypyrrole matrix.

    Science.gov (United States)

    Kazemikia, Kaveh; Bonabi, Fahimeh; Asadpoorchallo, Ali; Shokrzadeh, Majid

    2015-02-01

    In this work, an optimized pulsed magnetic field production apparatus is designed based on a RLC (Resistance/Self-inductance/Capacitance) discharge circuit. An algorithm for designing an optimum magnetic coil is presented. The coil is designed to work at room temperature. With a minor physical reinforcement, the magnetic flux density can be set up to 12 Tesla with 2 ms duration time. In our design process, the magnitude and the length of the magnetic pulse are the desired parameters. The magnetic field magnitude in the RLC circuit is maximized on the basis of the optimal design of the coil. The variables which are used in the optimization process are wire diameter and the number of coil layers. The coil design ensures the critically damped response of the RLC circuit. The electrical, mechanical, and thermal constraints are applied to the design process. A locus of probable magnetic flux density values versus wire diameter and coil layer is provided to locate the optimum coil parameters. Another locus of magnetic flux density values versus capacitance and initial voltage of the RLC circuit is extracted to locate the optimum circuit parameters. Finally, the application of high magnetic fields on carbon nanotube-PolyPyrrole (CNT-PPy) nano-composite is presented. Scanning probe microscopy technique is used to observe the orientation of CNTs after exposure to a magnetic field. The result shows alignment of CNTs in a 10.3 Tesla, 1.5 ms magnetic pulse.

  17. Electron self-injection for the acceleration in laser-pulse-wakes in the presence of a `strong' external magnetic field

    CERN Document Server

    Zhidkov, A; Masuda, S; Oishi, Y; Fujii, T; Kodama, R

    2012-01-01

    An external static magnetic field with its strength B~10T may result in the laser wake wave-breaking upon changing the electron motion in the vicinity of maximal density ramp of a wave period. This, as shown by numerical simulations, can change the resonance character of the electron self-injection in the laser wake-field; a total charge loaded in the acceleration phase of laser pulse wake can be controlled by a proper choice of the magnetic field strength.

  18. Magnetic Field Topology in Jets

    Science.gov (United States)

    Gardiner, T. A.; Frank, A.

    2000-01-01

    We present results on the magnetic field topology in a pulsed radiative. jet. For initially helical magnetic fields and periodic velocity variations, we find that the magnetic field alternates along the, length of the jet from toroidally dominated in the knots to possibly poloidally dominated in the intervening regions.

  19. Magnetic Flux-Trapping of Anisotropic-Grown Y-Ba-Cu-O Bulk Superconductors during and after Pulsed-Field Magnetizing Processes

    Science.gov (United States)

    Oka, T.; Yamada, Y.; Horiuchi, T.; Ogawa, J.; Fukui, S.; Sato, T.; Yokoyama, K.; Langer, M.

    2014-05-01

    The magnetic flux penetration into the melt-textured Y-Ba-Cu-O high temperature superconducting bulk magnets were precisely evaluated during and after the pulsed field magnetization processes operated at 30 K. The bulk magnets were carefully fabricated by the cold seeding method with use of a single and a pair of seed crystals composed of the Nd-Ba-Cu-O thin films. These seed crystals were put on the top surfaces of the precursors to let the large grains grow during the heat treatments. We observed the flux penetrations which occurred in the lower applied-field regions at around 3.1 T for the samples bearing the twin seeds than those of the single-seeded crystals at around 3.8 T. This means that the magnetic fluxes are capable of invading into the twin-seeded samples more easily than the single-seeds. It suggests that the anisotropic grain growths of parallel and normal to the rows of seed crystals affects the variations of Jc values with different distributions of the pinning centers, results in the preferential paths for the invading magnetic fluxes.

  20. Effects of pulsed magnetic field treatment of soybean seeds on calli growth, cell damage, and biochemical changes under salt stress.

    Science.gov (United States)

    Radhakrishnan, Ramalingam; Leelapriya, Thasari; Kumari, Bollipo Diana Ranjitha

    2012-12-01

    The effects of magnetic field (MF) treatments of soybean seeds on calli growth, cell damage, and biochemical changes under salt stress were investigated under controlled conditions. Soybean seeds were exposed to a 1.0 Hz sinusoidal uniform pulsed magnetic field (PMF) of 1.5 µT for 5 h/day for 20 days. Non-treated seeds were considered as controls. For callus regeneration, the embryonic axis explants were taken from seeds and inoculated in a saline medium with a concentration of 10 mM NaCl for calli growth analysis and biochemical changes. The combined treatment of MF and salt stress was found to significantly increase calli fresh weight, total soluble sugar, total protein, and total phenol contents, but it decreased the ascorbic acid, lipid peroxidation, and catalase activity of calli from magnetically exposed seeds compared to the control calli. PMF treatment significantly improved calli tolerance to salt stress in terms of an increase in flavonoid, flavone, flavonole, alkaloid, saponin, total polyphenol, genistein, and daidzein contents under salt stress. The results suggest that PMF treatment of soybean seeds has the potential to counteract the adverse effects of salt stress on calli growth by improving primary and secondary metabolites under salt stress conditions.

  1. Field-stepped broadband NMR in pulsed magnets and application to SrCu2(BO3)2 at 54 T

    Science.gov (United States)

    Kohlrautz, J.; Haase, J.; Green, E. L.; Zhang, Z. T.; Wosnitza, J.; Herrmannsdörfer, T.; Dabkowska, H. A.; Gaulin, B. D.; Stern, R.; Kühne, H.

    2016-10-01

    Pulsed magnets generate the highest magnetic fields as brief transients during which the observation of NMR is difficult, however, this is the only route to unique insight into material properties up to the regime of 100 T. Here, it is shown how rather broad NMR spectra can be assembled in a pulsed magnet during a single field pulse by using the inherent time dependence of the field for the recording of field-stepped free induction decays that cover a broad frequency range. The technique is then applied to 11B NMR of the spin-dimer system SrCu2(BO3)2, a magnetic insulator known to undergo a series of field-driven changes of the magnetic ground state. At peak fields of about 54T at the Dresden High Magnetic Field Laboratory, 11B NMR spectra spanning a total of about 9MHz width are reconstructed. The results are in good accordance with a change from a high-temperature paramagnetic state to a low-temperature commensurate superstructure of field-induced spin-dimer triplets.

  2. MOA—The Magnetic Field Amplified Thruster, a Novel Concept for a Pulsed Plasma Accelerator

    Science.gov (United States)

    Frischauf, Norbert; Hettmer, Manfred; Grassauer, Andreas; Bartusch, Tobias; Koudelka, Otto

    2008-01-01

    More than 60 years after the later Nobel laureate Hannes Alfvén had published a letter stating that oscillating magnetic fields can accelerate ionised matter via magneto-hydrodynamic interactions in a wave like fashion, the technical implementation of Alfvén waves for propulsive purposes has been proposed, patented and examined for the first time by a group of inventors. The name of the concept is MOA—Magnetic field Oscillating Amplified thruster. Based on computer simulations, MOA is a highly flexible propulsion system, whose performance parameters might easily be adapted, by changing the mass flow and/or the power level. As such the system is capable to deliver a maximum specific impulse of 13116 s (12.87 mN) at a power level of 11.16 kW, using Xe as propellant, but can also be attuned to provide a thrust of 236.5 mN (2411 s) at 6.15 kW of power. While space propulsion is expected to be the prime application for MOA and is supported by numerous applications such as Solar and/or Nuclear Electric Propulsion or even as an `afterburner system' for Nuclear Thermal Propulsion, other terrestrial applications can be thought of as well, making the system highly suited for a common space-terrestrial application research and utilisation strategy. This paper presents the recent developments of the MOA Thruster R&D activities at QASAR (www.qasar.at), the company in Vienna, which has been set up to further develop and test the Alfvén wave technology and its applications.

  3. Generation of Helical and Axial Magnetic Fields by the Relativistic Laser Pulses in Under-dense Plasma: Three-Dimensional Particle-in-Cell Simulation

    Institute of Scientific and Technical Information of China (English)

    郑春阳; 朱少平; 贺贤土

    2002-01-01

    The quasi-static magnetic fields created in the interaction of relativistic laser pulses with under-dense plasmashave been investigated by three-dimensional particle-in-cell simulation. The relativistic ponderomotive force candrive an intense electron current in the laser propagation direction, which is responsible for the generation ofa helical magnetic field. The axial magnetic field results from a difference beat of wave-wave, which drives asolenoidal current. In particular, the physical significance of the kinetic model for the generation of the axialmagnetic field is discussed.

  4. Enhancement of zinc vacancies in room-temperature ferromagnetic Cr–Mn codoped ZnO nanorods synthesized by hydrothermal method under high pulsed magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Min [Laboratory for Microstructures/School of Materials Science and Engineering, Shanghai University, 149 Yanchang Road, 200072 Shanghai (China); Li, Ying, E-mail: liying62@shu.edu.cn [Laboratory for Microstructures/School of Materials Science and Engineering, Shanghai University, 149 Yanchang Road, 200072 Shanghai (China); Hu, Yemin; Zhu, Mingyuan; Li, Wenxian; Jin, Hongmin; Wang, Shiwei [Laboratory for Microstructures/School of Materials Science and Engineering, Shanghai University, 149 Yanchang Road, 200072 Shanghai (China); Li, Yibing; Zhao, Huijun [Centre for Clean Environment and Energy, Griffith School of Environment, Griffith University, Gold Coast Campus, QLD 4222 (Australia)

    2015-10-25

    Room-temperature ferromagnetic Cr–Mn codoped ZnO diluted magnetic semiconductor was synthesized by pulse magnetic field-assisted hydrothermal method. X-ray diffraction and Raman spectra analysis reveal that all the samples have hexagonal wurtzite structure. High resolution transmission electron microscopy and Energy-dispersive spectroscopy measurements ensure that the Cr and Mn ions are incorporated into the wurtzite host matrix without any detectable impurity phase. X-ray photoelectron spectroscopy confirms that Mn and Cr ions are doped into the ZnO wurtzite host matrix with divalent states in the sample without magnetic field processing. Cr ions became trivalent states in ZnO synthesized with high pulsed magnetic field, while Mn keeps its divalent state. The presence of Cr{sup 3+} is attributed to hole doping in ZnO with zinc vacancies induced by the field. Magnetization measurements reveal the appearance of ferromagnetism for the magnetic field processed sample. Comparing with oxygen vacancies, zinc vacancies (hole doping) is more effectively to stabilized ferromagnetism in Mn-doped ZnO diluted magnetic semiconductors. - Graphical abstract: This figure shows the magnetization versus magnetic field curves for ZnO–Cr–Mn-0T and ZnO–Cr–Mn-4T at 290 K. The 4 T sample was well-defined hysteresis loops, which is indicative of room-temperature ferromagnetic behavior. But for 0 T sample, no ferromagnetic response at 290 K is observed. The hole doping enhanced by high pulsed magnetic field is crucial to stabilize ferromagnetism in Mn-doped ZnO diluted magnetic semiconductor. And the presence of Cr{sup 3+} in 4 T sample is a possible signature of hole doping induced by zinc vacancies. - Highlights: • Cr–Mn codoped ZnO nanorods were synthesized by hydrothermal method. • High pulsed magnetic field was applied during the hydrothermal method. • The valence state of doped elements was investigated by XPS. • High pulsed magnetic field enhances the

  5. Reactor for boron fusion with picosecond ultrahigh power laser pulses and ultrahigh magnetic field trapping

    CERN Document Server

    Miley, G H; Kirchhoff, G

    2015-01-01

    Compared with the deuterium tritium (DT) fusion, the environmentally clean fusion of protons with 11B is extremely difficult. When instead of nanosecond laser pulses for thermal-ablating driven ignition, picosecond pulses are used, a drastic change by nonlinearity results in ultrahigh acceleration of plasma blocks. This radically changes to economic boron fusion by a measured new avalanche ignition.

  6. Magnetic Alignment of Pulsed Solenoids Using the Pulsed Wire Method

    Energy Technology Data Exchange (ETDEWEB)

    Arbelaez, D.; Madur, A.; Lipton, T.M.; Waldron, W.L.; Kwan, J.W.

    2011-04-01

    A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 {micro}m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.

  7. Lateral diffusion of PEG-Lipid in magnetically aligned bicelles measured using stimulated echo pulsed field gradient 1H NMR.

    Science.gov (United States)

    Soong, Ronald; Macdonald, Peter M

    2005-01-01

    Lateral diffusion measurements of PEG-lipid incorporated into magnetically aligned bicelles are demonstrated using stimulated echo (STE) pulsed field gradient (PFG) proton (1H) nuclear magnetic resonance (NMR) spectroscopy. Bicelles were composed of dimyristoyl phosphatidylcholine (DMPC) plus dihexanoyl phosphatidylcholine (DHPC) (q = DMPC/DHPC molar ratio = 4.5) plus 1 mol % (relative to DMPC) dimyristoyl phosphatidylethanolamine-N-[methoxy(polyethylene glycol)-2000] (DMPE-PEG 2000) at 25 wt % lipid. 1H NMR STE spectra of perpendicular aligned bicelles contained only resonances assigned to residual HDO and to overlapping contributions from a DMPE-PEG 2000 ethoxy headgroup plus DHPC choline methyl protons. Decay of the latter's STE intensity in the STE PFG 1H NMR experiment (g(z) = 244 G cm(-1)) yielded a DMPE-PEG 2000 (1 mol %, 35 degrees C) lateral diffusion coefficient D = 1.35 x 10(-11) m2 s(-1). Hence, below the "mushroom-to-brush" transition, DMPE-PEG 2000 lateral diffusion is dictated by its DMPE hydrophobic anchor. D was independent of the diffusion time, indicating unrestricted lateral diffusion over root mean-square diffusion distances of microns, supporting the "perforated lamellae" model of bicelle structure under these conditions. Overall, the results demonstrate the feasibility of lateral diffusion measurements in magnetically aligned bicelles using the STE PFG NMR technique.

  8. Localized stimulation of the human brain and spinal cord by a pair of opposing pulsed magnetic fields

    Science.gov (United States)

    Ueno, S.; Matsuda, T.; Hiwaki, O.

    1990-05-01

    A method of localized stimulation of the human brain and spinal cord is proposed. The basic idea is to concentrate induced eddy currents locally in the vicinity of a target by a pair of opposing pulsed magnetic fields. A pair of coils are positioned outside the head in the opposite directions around a target. The eddy currents induced at the target are expected to flow together, which results in an increased current flow at the target. A figure-eight coil is designed, and the magnetic brain stimulation is carried out using ourselves as volunteers. The results show that the selective stimulation of the brain is realized with a 5-mm resolution. The functional mapping of the human motor cortex related to the hand, arm, and foot areas is obtained. It is also obtained that an optimum direction of stimulating currents for neural excitation exists in each functional area in the cortex. Magnetic stimulation of the spinal cord is carried out by the same method as used in the brain stimulation. Rabbits are used in the experiments. A figure-eight coil is positioned on the surface of the spine. Shifting the stimulating points on the spine, electromyographic (EMG) signals are recorded from limb muscles. The EMG signals are clearly responding to the stimulation at a segment which innervates limb muscles, whereas no EMG signals are obtained by stimulation of segments higher than the critical segment. It is also obtained that the amplitude of the EMG signals varies with the direction of stimulating currents.

  9. Pulsed magnetic field improves seed quality of aged green pea seeds by homeostasis of free radical content.

    Science.gov (United States)

    Bhardwaj, Jyotsna; Anand, Anjali; Pandita, V K; Nagarajan, Shantha

    2016-11-01

    To elucidate the mechanism responsible for magnetic field induced seed invigoration in aged seeds an experiment was conducted on six year old garden pea seeds stored under controlled (20 °C and 40% RH) condition. Aged seeds were magnetoprimed by exposing to pulsed magnetic field (PMF) of 100 mT for 1 h in three pulsed modes. The 6 min on and off PMF showed significant improvement in germination (7.6%) and vigor (84.8%) over aged seeds. Superoxide and hydrogen peroxide production increased in germinating primed seeds by 27 and 52%, respectively, over aged seeds. Nicotinamide adenine dinucleotide (reduced) (NADH) peroxidase and superoxide dismutase involved in generation of hydrogen peroxide showed increased activity in PMF primed seeds. Increase in catalase, ascorbate peroxidase and glutathione reductase activity after 36 h of imbibition in primed seeds demonstrated its involvement in seed recovery during magnetopriming. An increase in total antioxidants also helped in maintaining the level of free radicals for promoting germination of magnetoprimed seeds. A 44% increase in level of protein carbonyls after 36 h indicated involvement of protein oxidation for counteracting and/or utilizing the production of ROS and faster mobilization of reserve proteins. Higher production of free radicals in primed seeds did not cause lipid peroxidation as malondialdehyde content was low. Lipoxygenase was involved in the germination associated events as the magnitude of activity was higher in primed aged seeds compared to aged seeds. Our study elucidated that PMF mediated improvement in seed quality of aged pea seeds was facilitated by fine tuning of free radicals by the antioxidant defense system and protein oxidation.

  10. Pulse Field Gel Electrophoresis.

    Science.gov (United States)

    Sharma-Kuinkel, Batu K; Rude, Thomas H; Fowler, Vance G

    2016-01-01

    Pulse Field Gel Electrophoresis (PFGE) is a powerful genotyping technique used for the separation of large DNA molecules (entire genomic DNA) after digesting it with unique restriction enzymes and applying to a gel matrix under the electric field that periodically changes direction. PFGE is a variation of agarose gel electrophoresis that permits analysis of bacterial DNA fragments over an order of magnitude larger than that with conventional restriction enzyme analysis. It provides a good representation of the entire bacterial chromosome in a single gel with a highly reproducible restriction profile, providing clearly distinct and well-resolved DNA fragments.

  11. The polaron effect in GaAs-(Al,Ga)As studied with a pulsed-field magnet: Free-electron-laser combination

    NARCIS (Netherlands)

    Langerak, Cjgm; Li, L.; Van Bockstal, L.; Ardavan, A.; van de Pol, M.J.; van der Meer, A. F. G.; Herlach, F.; Mueller, H. U.; Nicholas, R. J.; Singleton, J.

    1998-01-01

    The combination of a 60 T pulsed-field magnet and the continuous tunability of a high power, picosecond free-electron laser provides a powerful facility to study, e.g. cyclotron resonance in a wide range of materials with different effective masses and over a wide range of energies. Here we present

  12. Magnetic field turbulence, electron heating, magnetic holes, proton cyclotron waves, and the onsets of bipolar pulse (electron hole events: a possible unifying scenario

    Directory of Open Access Journals (Sweden)

    B. T. Tsurutani

    2003-01-01

    Full Text Available Two electron heating events have been identified on 20 May 1996 when Polar was in the polar cap/polar cusp boundary layer. The electron heating events were located within magnetic holes/cavities/bubbles and were accompanied by nonlinear ± 14 nT peak-to-peak (f ~ 0.6 to 0.7 fcp obliquely propagating proton cyclotron waves. The electrons appear to be heated isotropically. Electric bipolar pulse (electron hole onset events were also detected within the heating events. We propose a scenario which can link the above phenomena. Nonlinear Alfvén waves, generated through cusp magnetic reconnection, propagate down magnetic field lines and locally heat electrons through the ponderomotive force. The magnetic cavity is created through the diamagnetic effect of the heated electrons. Ion heating also occurs through ponderomotive acceleration (but much less than the electrons and the protons generate the electromagnetic proton cyclotron waves through the loss cone instability. The obliquely propagating electromagnetic proton cyclotron waves accelerate bi-streaming electrons, which are the source of free energy for the electron holes.

  13. Terahertz cyclotron resonance spectroscopy of an AlGaN/GaN heterostructure using a high-field pulsed magnet and an asynchronous optical sampling technique

    Science.gov (United States)

    Spencer, B. F.; Smith, W. F.; Hibberd, M. T.; Dawson, P.; Beck, M.; Bartels, A.; Guiney, I.; Humphreys, C. J.; Graham, D. M.

    2016-05-01

    The effective mass, sheet carrier concentration, and mobility of electrons within a two-dimensional electron gas in an AlGaN/GaN heterostructure were determined using a laboratory-based terahertz cyclotron resonance spectrometer. The ability to perform terahertz cyclotron resonance spectroscopy with magnetic fields of up to 31 T was enabled by combining a high-field pulsed magnet with a modified asynchronous optical sampling terahertz detection scheme. This scheme allowed around 100 transmitted terahertz waveforms to be recorded over the 14 ms magnetic field pulse duration. The sheet density and mobility were measured to be 8.0 × 1012 cm-2 and 9000 cm2 V-1 s-1 at 77 K. The in-plane electron effective mass at the band edge was determined to be 0.228 ± 0.002m0.

  14. A detailed ethological analysis of the mouse open field test: effects of diazepam, chlordiazepoxide and an extremely low frequency pulsed magnetic field.

    Science.gov (United States)

    Choleris, E; Thomas, A W; Kavaliers, M; Prato, F S

    2001-05-01

    The open field test (OFT) is a widely used procedure for examining the behavioral effects of drugs and anxiety. Detailed ethological assessments of animal behavior are lacking. Here we present a detailed ethological assessment of the effects of acute treatment with the benzodiazepines, diazepam (DZ, 1.5mg/kg) and chlordiazepoxide (CDP, 5.0 and 10.0mg/kg), as well as exposure to a non-pharmacological agent, a specific pulsed extremely low frequency magnetic field (MAG) on open field behavior. We examined the duration, frequency and time course of various behaviors (i.e. exploration, walk, rear, stretch attend, return, groom, sit, spin turn, jump and sleep) exhibited by male mice in different regions of a novel open field. Both DZ and CDP consistently reduced the typical anxiety-like behaviors of stretch attend and wall-following (thigmotaxis), along with that of an additional new measure: 'returns', without producing any overall effects on total locomotion. The drugs also differed in their effects. CDP elicited a shift in the locomotor pattern from a 'high explore' to a 'high walk', while DZ mainly elicited alterations in sit and groom. The MAG treatment was repeated twice with both exposures reducing horizontal and vertical (rearing) activity and increasing grooming and spin turns. However, the anxiety-like behaviors of stretch attend and return were marginally reduced by only the first exposure. We conclude that a detailed ethological analysis of the OFT allows not only the detection of specific effects of drugs and non-pharmacological agents (i.e. pulsed magnetic field) on anxiety-like behaviors, but also permits the examination of non-specific effects, in particular those on general activity.

  15. Theoretical Investigation of Dynamic Properties of Magnetic Molecule Systems as Probed by NMR and Pulsed Fields Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Rousochatzakis, Ioannis [Iowa State Univ., Ames, IA (United States)

    2005-12-17

    The field of molecular magnetism[l-6] has become a subject of intense theoretical and experimental interest and has rapidly evolved during the last years. This inter-disciplinary field concerns magnetic systems at the molecular or "nanoscopic" level, whose realization has become feasible due to recent advances in the field of chemical synthesis. The present theoretical work provides a first step towards exploiting the possibilities that are offered by probing magnetic molecules using external magnetic fields with high sweep rates. These probes, apart for providing information specific to magnetic molecules, offer the possibility of conducting a detailed study of the relaxational behavior of interacting spin systems as a result of their coupling with a "heat bath" and in particular the excitations of the host lattice. Development of a broad theoretical framework for dealing with relaxational phenomena induced by dynamical magnetic fields is indeed a worthy goal.

  16. ISR split-field magnet

    CERN Multimedia

    1975-01-01

    The experimental apparatus used at intersection 4 around the Split-Field Magnet by the CERN-Bologna Collaboration (experiment R406). The plastic scintillator telescopes are used for precise pulse-height and time-of-flight measurements.

  17. Proceedings of Pulsed Magnet Design and Measurement Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Shaftan, T.; Heese, R.; Ozaki,S.

    2010-01-19

    The goals of the Workshop are to assess the design of pulsed system at the NSLS-II and establish mitigation strategies for critical issues during development. The focus of the Workshop is on resolving questions related to the set-up of the pulsed magnet laboratory, on measuring the pulsed magnet's current waveforms and fields, and on achieving tight tolerances on the magnet's alignment and field quality.

  18. The effects of pulsed low frequency magnetic field in early rehabilitation of patients with cementless total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2006-01-01

    Full Text Available Introduction: Early rehabilitation of patients with cementless total hip arthroplasty (cTHA includes different physical modalities and pulsed low frequency magnetic field (PLFMF, which effects have not been explored yet. Objective: To investigate the effects of PLFMF which was applied in different doses in early rehabilitation of patients with cTHA. Method: Prospective, controlled, clinical study included 90 patients, divided in three groups with 30 patients each. First two groups were treated with high (group A or low (group B doses of PLFMF, in addition to kinesitherapy. Control group C was treated only with kinesitherapy. Study was completed in three weeks. Results: Subjects of group A had significantly lower pain than group B (p<0.01 and group C (p<0.001 subjects in the first postoperative week. Pain in group B subjects was significantly lower than in group C in all three postoperative weeks (p<0.01. In relation to other two groups, subjects of group A had higher hip Harris score values at the end of the third postoperative week (p<0.05, and they were faster on 10-meter distance at the end of the first postoperative week (p<0.01. Conclusion: PLFMF used in low and high doses for patients with cTHA had significant effects on pain abatement, especially at higher doses. Improvement of function was earlier and more manifested in the group treated with high doses of PLFMF.

  19. Influence of pulsed magnetic field on soybean (Glycine max L.) seed germination, seedling growth and soil microbial population.

    Science.gov (United States)

    Radhakrishnan, Ramalingam; Kumari, Bollipo Dyana Ranjitha

    2013-08-01

    The effects of pulsed magnetic field (PMF) treatment of soybean (Glycine max L. cv CO3) seeds were investigated on rate of seed germination, seedling growth, physico-chemical properties of seed leachates and soil microbial population under laboratory conditions. Seeds were exposed to PMF of 1500 nT at 0.1, 1.0 10.0 and 100.0 Hz for 5 h per day for 20 days, induced by enclosure coil systems. Non-treated seeds were considered as controls. All PMF treatments significantly increased the rate of seed germination, while 10 and 100 Hz PMFs showed the most effective response. The 1.0 and 10 Hz PMFs remarkably improved the fresh weight of shoots and roots, leaf area and plant height from seedlings from magnetically-exposed seeds compared to the control, while 10 Hz PMF increased the total soluble sugar, total protein and phenol contents. The leaf chlorophyll a, b and total chlorophyll were higher in PMF (10 and 100 Hz) pretreated plants, as compared to other treatments. In addition, activities of alpha-amylase, acid phosphatase, alkaline phosphatase, nitrate reductase, peroxidase and polyphenoloxidase were increased, while beta-amylase and protease activities were declined in PMF (10 Hz)-exposed soybean plants. Similarly, the capacity of absorbance of water by seeds and electrical conductivity of seed leachates were significantly enhanced by 10 Hz PMF exposure, whereas PMF (10 Hz) pretreated plants did not affect the microbial population in rhizosphere soil. The results suggested the potential of 10 Hz PMF treatment to enhance the germination and seedling growth of soybean.

  20. Statistical Investigations on Solar Wind Dynamic Pressure Pulses:Basic features and Their Impacts on Geosynchronous Magnetic Fields

    Science.gov (United States)

    Zuo, Pingbing; Feng, Xueshang

    2016-07-01

    Solar wind dynamic pressure pulse (DPP) structures, across which the dynamic pressure abruptly changes over timescales from a few seconds to several minutes, are often observed in the near-Earth space environment. Recently we have developed a novel procedure that is able to rapidly identify the DPPs from the plasma data stream, and simultaneously define the transition region and smartly select the upstream and downstream region for analysis. The plasma data with high time-resolution from 3DP instrument on board the WIND spacecraft are inspected with this automatic DPP-searching code, and a complete list of solar wind DPPs of historic WIND observations are built up. We perform a statistical survey on the properties of DPPs near 1 AU based on this event list. It is found that overwhelming majority of DPPs are associated with the solar wind disturbances including the CME-related flows, the corotating interaction regions, as well as the complex ejecta. The annual variations of the averaged occurrence rate of DPPs are roughly in phase with the solar activities. Although the variabilities of geosynchronous magnetic fields (GMFs) due to the impact of positive DPPs have been well established, there appears no systematic investigations on the response of GMFs to negative DPPs. Here we also study the decompression/compression effects of very strong negative/positive DPPs on GMFs under northward IMFs. In response to the decompression of strong negative DPPs, GMFs on dayside, near the dawn and dusk on nightside are generally depressed. But near the midnight region, the responses of GMF are very diverse, being either positive or negative. For part of events when GOES is located at the midnight sector, GMF is found to abnormally increase as the result of magnetospheric decompression caused by negative DPPs. It is known that on certain conditions magnetic depression of nightside GMFs can be caused by the impact of positive DPPs. Statistically, both the decompression effect of

  1. Evaluation of Safety and Patient Subjective Efficacy of Using Radiofrequency and Pulsed Magnetic Fields for the Treatment of Striae (Stretch Marks)

    OpenAIRE

    Dover, Jeffrey S.; Rothaus, Kenneth; Gold, Michael H.

    2014-01-01

    Stretch marks are common skin disorders that are dermal scars with associated epidermal atrophy. They are of significant concern or psychological concern to many. This manuscript describes the use of multipolar radiofrequency with pulsed magnetic fields that was successfully used to diminish these lesions in 16 subjects undergoing a series of treatments. The improvements noted were statistically significant and no serious adverse events were noted.

  2. Evaluation of safety and patient subjective efficacy of using radiofrequency and pulsed magnetic fields for the treatment of striae (stretch marks).

    Science.gov (United States)

    Dover, Jeffrey S; Rothaus, Kenneth; Gold, Michael H

    2014-09-01

    Stretch marks are common skin disorders that are dermal scars with associated epidermal atrophy. They are of significant concern or psychological concern to many. This manuscript describes the use of multipolar radiofrequency with pulsed magnetic fields that was successfully used to diminish these lesions in 16 subjects undergoing a series of treatments. The improvements noted were statistically significant and no serious adverse events were noted.

  3. Composite superconducting bulks for efficient heat dissipation during pulse magnetization

    Science.gov (United States)

    Baskys, A.; Patel, A.; Hopkins, S.; Kenfaui, D.; Chaud, X.; Zhang, M.; Glowacki, B. A.

    2014-05-01

    Pulsed field magnetization is the most practical method of magnetizing a (RE)BCO bulk, however large heat generation limits the trapped field to significantly less than possible using field cooling. Modelling has been used to show that effective heat removal from the bulk interior, using embedded metallic structures, can enhance trapped field by increasing thermal stability. The reported results are for experimental pulsed magnetization of a thin walled YBCO sample with 55 vertical holes embedded with high thermal conductivity wires. A specially designed copper coldhead was used to increase the trapped field and flux of the perforated YBCO by about 12% at 35 K using a multi-pulse magnetization. Moreover, by filling the perforations with copper, the central trapped field was enhanced by 15% after a single-pulse at 35 K. 3D FEM computer model of a perforated YBCO bulk was also developed showing localised heating effects around the perforations during pulse magnetisation.

  4. Magnetic field induced random pulse trains of magnetic and acoustic noises in martensitic single-crystal Ni2MnGa

    Science.gov (United States)

    Daróczi, Lajos; Piros, Eszter; Tóth, László Z.; Beke, Dezső L.

    2017-07-01

    Jerky magnetic and acoustic noises were evoked in a single variant martensitic Ni2MnGa single crystal (produced by uniaxial compression) by application of an external magnetic field along the hard magnetization direction. It is shown that after reaching the detwinning threshold, spontaneous reorientation of martensite variants (twins) leads not only to acoustic emission but magnetic two-directional noises as well. At small magnetic fields, below the above threshold, unidirectional magnetic emission is also observed and attributed to a Barkhausen-type noise due to magnetic domain wall motions during magnetization along the hard direction. After the above first run, in cycles of decreasing and increasing magnetic field, at low-field values, weak, unidirectional Barkhausen noise is detected and attributed to the discontinuous motion of domain walls during magnetization along the easy magnetization direction. The magnetic noise is also measured by constraining the sample in the same initial variant state along the hard direction and, after the unidirectional noise (as obtained also in the first run), a two-directional noise package is developed and it is attributed to domain rotations. From the statistical analysis of the above noises, the critical exponents, characterizing the power-law behavior, are calculated and compared with each other and with the literature data. Time correlations within the magnetic as well as acoustic signals lead to a common scaled power function (with β =-1.25 exponent) for both types of signals.

  5. Pulsed-coil magnet systems for applying uniform 10-30 T fields to centimeter-scale targets on Sandia's Z facility

    Science.gov (United States)

    Rovang, D. C.; Lamppa, D. C.; Cuneo, M. E.; Owen, A. C.; McKenney, J.; Johnson, D. W.; Radovich, S.; Kaye, R. J.; McBride, R. D.; Alexander, C. S.; Awe, T. J.; Slutz, S. A.; Sefkow, A. B.; Haill, T. A.; Jones, P. A.; Argo, J. W.; Dalton, D. G.; Robertson, G. K.; Waisman, E. M.; Sinars, D. B.; Meissner, J.; Milhous, M.; Nguyen, D. N.; Mielke, C. H.

    2014-12-01

    Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10-30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1-3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2-7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

  6. International comparison of the properties of NdFeB permanent magnets measured using an electromagnet and a pulsed field magnetometer

    Science.gov (United States)

    Hall, Michael

    2013-08-01

    An IEC TC 68 comparison on the measurement of the magnetic properties of permanent magnets was completed in 2011. Measurements were performed on 6 NdFeB magnets with intrinsic coercivities ranging from 1000 to 2600 kA/m by 8 institutes based in China, Japan, Italy, Belgium, Germany and the UK. Many versions of a Pulsed Field Magnetometer (PFM) that can determine the full BH curve in as little as 100 ms have been developed during the last 2 decades. By comparing measurements made using an internationally accepted electromagnet method and pulsed methods, the influence of the dynamic effects of the latter could be investigated and established. For the quantities remanence, B r , magnetic flux density coercivity, H cB and energy product, BH max the measurements agree within the combined uncertainties. For the intrinsic coercivity, H cJ , the dependence of the measurement of this quantity on the speed at which the magnetic field is reversed was found to be significant with the largest changes in value occurring as a DC measurement condition is approached.

  7. First test of a power-pulsed electronics system on a GRPC detector in a 3-Tesla magnetic field

    CERN Document Server

    Caponetto, L; de la Taille, C; Dulucq, F; Kieffer, R; Laktineh, I; Lumb, N; Mirabito, L; Seguin-Moreau, N

    2012-01-01

    An important technological step towards the realization of an ultra-granular hadronic calorimeter to be used in the future International Linear Collider (ILC) experiments has been made. A 33X50 cm2 GRPC detector equipped with a power-pulsed electronics board offering a 1cm2 lateral segmentation was successfully tested in a 3-Tesla magnet operating at the H2 beam line of the CERN SPS. An important reduction of power consumption with no deterioration of the detector performance is obtained when the power-pulsing mode is applied. This important result shows that ultra-granular calorimeters for ILC experiments are not only an attractive but also a realistic option.

  8. The change of electric potentials in the oral cavity after application of extremely low frequency pulsed magnetic field

    Directory of Open Access Journals (Sweden)

    Piotr Skomro

    2012-12-01

    Full Text Available Electric potentials occurring in the oral cavity deserve attention as they may cause various diseases and subjective feelings, which are very difficult to treat. The aim of this study was to evaluate the electric potentials within the oral cavity in patients with metal fillings and metal prosthetic restorations, after using a pulsed electromagnetic field. The study was carried out on 84 patients. The Viofor JPS Classic device was used in the treatment. It generates a pulsed electromagnetic field with low induction of the extremely low frequency (ELF range. Average values of electric potentials in the preliminary test were about the same in both groups; they were 148.8 mV and 145.5 mV. After another appliance of ELF fields there was found a steady decline in the average value of electric potentials in the study group. This decrease was statistically highly significant, while mean values of electric potentials in the control group were characterized by a slightly upward tendency. The obtained statistically significant reduction of electric potentials in the oral cavity of patients having metal fillings and metal prosthetic restorations, after application of the Viofor JPS Classic device, implies a huge impact of ELF pulsed electromagnetic field on inhibition of electrochemical processes, as well as on inhibition of dental alloy corrosion. 

  9. The change of electric potentials in the oral cavity after application of extremely low frequency pulsed magnetic field.

    Science.gov (United States)

    Skomro, Piotr; Lietz-Kijak, Danuta; Kijak, Edward; Bogdziewicz-Wałęsa, Olga; Opalko, Krystyna

    2012-12-11

    Electric potentials occurring in the oral cavity deserve attention as they may cause various diseases and subjective feelings, which are very difficult to treat. The aim of this study was to evaluate the electric potentials within the oral cavity in patients with metal fillings and metal prosthetic restorations, after using a pulsed electromagnetic field. The study was carried out on 84 patients. The Viofor JPS Classic device was used in the treatment. It generates a pulsed electromagnetic field with low induction of the extremely low frequency (ELF) range. Average values of electric potentials in the preliminary test were about the same in both groups; they were 148.8 mV and 145.5 mV. After another appliance of ELF fields there was found a steady decline in the average value of electric potentials in the study group. This decrease was statistically highly significant, while mean values of electric potentials in the control group were characterized by a slightly upward tendency. The obtained statistically significant reduction of electric potentials in the oral cavity of patients having metal fillings and metal prosthetic restorations, after application of the Viofor JPS Classic device, implies a huge impact of ELF pulsed electromagnetic field on inhibition of electrochemical processes, as well as on inhibition of dental alloy corrosion. 

  10. Observation of self-magnetic field relaxations in Bi2223 and Y123 HTS tapes after over-current pulse and DC current operation

    Science.gov (United States)

    Tallouli, M.; Sun, J.; Chikumoto, N.; Otabe, E. S.; Shyshkin, O.; Charfi-Kaddour, S.; Yamaguchi, S.

    2016-07-01

    The development of power transmission lines based on long-length HTS tapes requires the production of high quality tapes. Due to fault conditions, technical mistakes and human errors during the operation of a DC power transmission line, an over-current pulse, several times larger than the rated current, could occur. To study the effect of such over-current pulses on the transport current density distribution in the HTS tapes, we simulated two start-up scenarios for one BSCCO and two YBCO tapes. The first start-up scenario is an initial over-current pulse during which the transport current was turned on rapidly, rising to 900 A during the first milliseconds, then reduced to a 100 A DC current. The second start-up scenario is normal operation, and involved increasing the transport current slowly from 0 A to 100 A at a rate of 1 A/s. For both scenarios, we then measured the vertical component of the self-magnetic field by means of a Hall probe above the tape, and afterward, by solving a linear equation of the inverse problem we obtain the current density profiles. We observe a change of the self-magnetic field above the edge of the BSCCO and YBCO tapes during 30 min after the 5 ms of over-current pulse and during the normal operation. The current density profiles are peaked in the centre for over-current pulse, and more peaked around the edge of the HTS tape for normal operation, which means that the limited time over-current pulse changes the current density profiles of the HTS tapes. We observe also a loop of current for YBCO tapes and we show the role of the HTS tape stabilizer.

  11. Magnetic Field Calculator

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Magnetic Field Calculator will calculate the total magnetic field, including components (declination, inclination, horizontal intensity, northerly intensity,...

  12. Design and Realization of the Control and Measurement System of the Wuhan Pulsed High Magnetic Field Facility

    Science.gov (United States)

    Han, X. T.; Xie, J. F.; Song, Z. W.; Li, L.

    2010-04-01

    A user-friendly Control and Measurement System (CMS) is designed and realized at the Wuhan High Magnetic Field Center (WHMFC). Structure and functions of the CMS system are described in detail. Three kernel parts of CMS are discussed. The success of the comprehensive system test shows that the CMS is effective and reliable.

  13. Magnetic-Field Hazards Bibliography.

    Science.gov (United States)

    1985-09-01

    produced during pulsed- magnetic-field therapy for non-union of the tibia." Med. Biol. Eng. Comput., Vol. 20, pp. 501-511 (1982). 32. Miller, D. A...Phenum Publishing Co. (1983). 40. Topper, R. F., "Electromagnetic shielding feasibility study," ASD -TDR-63-194 (Armour Research Foundation, Chicago...mammalian cells by strong magnetic fields (1976). 93. Malins, D. C., and Collier, T. K., "Xenobiotic interactions in aquatic organisms-effects on

  14. 脉冲磁场激励下圆柱导体内瞬态涡流场的快速计算%Fast Calculation of Transient Eddy Current Field in Cylindrical Conductor Excited by Pulsed Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    辛伟

    2013-01-01

    The theoretical model of transient eddy current field is built in cylindrical conductor excited by pulsed magnetic field. Theoretical calculation and experimental measurement of cylindrical conductor in pulsed magnetic field are carried out. The theoretical results are compared with the experimental results in a good agreement, indicate that the fast calculation method of transient eddy current field in cylindrical conductor is effective.%建立了脉冲磁场激励下圆柱导体内瞬态涡流场的理论模型.实现了瞬态涡流场的快速计算.通过实例表明上述圆柱导体内瞬态涡流场的快速计算方法有效.

  15. A Compact High Gradient Pulsed Magnetic Quadrupole

    CERN Document Server

    Shuman, Derek; Kireeff Covo, Michel; Ritchie, Gary; Seidl, Peter

    2005-01-01

    A design for a high gradient, low inductance pulsed quadrupole magnet is presented. The magnet is a circular current dominated design with a circular iron return yoke. Features include a five turn eddy current compensated solid conductor coil design which theoretically eliminates the first four higher order multipole field components, a single layer "non-spiral bedstead" coil design which both minimizes utilization of radial space and maximizes utilization of axial space, and allows incorporation of steering and correction coils within existing radial space. The coils are wound and stretched straight in a special winder, then bent in simple fixtures to form the upturned ends, simplifying fabrication and assembly.

  16. Application of pulsed-magnetic field enhances non-viral gene delivery in primary cells from different origins

    Energy Technology Data Exchange (ETDEWEB)

    Kamau Chapman, Sarah W. [Institute of Veterinary Biochemistry and Molecular Biology, University of Zurich, Winterthurerstr. 190, 8057 Zurich (Switzerland); Hassa, Paul O. [Institute of Veterinary Biochemistry and Molecular Biology, University of Zurich, Winterthurerstr. 190, 8057 Zurich (Switzerland); European Molecular Biology Laboratory (EMBL) Heidelberg, Meyerhofstrasse 1, 69117 Heidelberg (Germany); Koch-Schneidemann, Sabine; Rechenberg, Brigitte von [Musculoskeletal Research Unit, Equine Hospital, Vetsuisse Faculty Zurich, University of Zurich, Winterthurerstr. 260, 8057 Zurich (Switzerland); Hofmann-Amtenbrink, Margarethe [MatSearch, Chemin Jean Pavillard 14, 1009 Pully (Switzerland); Steitz, Benedikt; Petri-Fink, Alke; Hofmann, Heinrich [Laboratory of Powder Technology, Ecole Polytechnique Federale de Lausanne (EPFL), Lausanne (Switzerland); Hottiger, Michael O. [Institute of Veterinary Biochemistry and Molecular Biology, University of Zurich, Winterthurerstr. 190, 8057 Zurich (Switzerland)], E-mail: hottiger@vetbio.uzh.ch

    2008-04-15

    Primary cell lines are more difficult to transfect when compared to immortalized/transformed cell lines, and hence new techniques are required to enhance the transfection efficiency in these cells. We isolated and established primary cultures of synoviocytes, chondrocytes, osteoblasts, melanocytes, macrophages, lung fibroblasts, and embryonic fibroblasts. These cells differed in several properties, and hence were a good representative sample of cells that would be targeted for expression and delivery of therapeutic genes in vivo. The efficiency of gene delivery in all these cells was enhanced using polyethylenimine-coated polyMAG magnetic nanoparticles, and the rates (17-84.2%) surpassed those previously achieved using other methods, especially in cells that are difficult to transfect. The application of permanent and pulsating magnetic fields significantly enhanced the transfection efficiencies in synoviocytes, chondrocytes, osteoblasts, melanocytes and lung fibroblasts, within 5 min of exposure to these magnetic fields. This is an added advantage for future in vivo applications, where rapid gene delivery is required before systemic clearance or filtration of the gene vectors occurs.

  17. Separation of the contributions to the magnetization of Tm1 - x Yb x B12 solid solutions in steady and pulsed magnetic fields

    Science.gov (United States)

    Bogach, A. V.; Sluchanko, N. E.; Glushkov, V. V.; Demishev, S. V.; Azarevich, A. N.; Filippov, V. B.; Shitsevalova, N. Yu.; Levchenko, A. V.; Vanacken, J.; Moshchalkov, V. V.; Gabani, S.; Flachbart, K.

    2013-05-01

    The magnetization of substitutional Tm1 - x Yb x B12 solid solutions is studied in the composition range 0 B12 compounds to be separated. These contributions include a Pauli component, which corresponds to the response of the heavy-fermion manybody states that appears in the energy gap in the vicinity of the Fermi level (density of states (3-4) × 1021 cm-3 meV-1), and a contribution with saturation in high magnetic fields attributed to the localized magnetic moments ((0.8-3.7)μB per unit cell) of the nanoclusters formed by rare-earth ions with an antiferromagnetic interaction.

  18. Pulsed Electromagnetic Field Assisted in vitro Electroporation: A Pilot Study

    Science.gov (United States)

    Novickij, Vitalij; Grainys, Audrius; Lastauskienė, Eglė; Kananavičiūtė, Rūta; Pamedytytė, Dovilė; Kalėdienė, Lilija; Novickij, Jurij; Miklavčič, Damijan

    2016-09-01

    Electroporation is a phenomenon occurring due to exposure of cells to Pulsed Electric Fields (PEF) which leads to increase of membrane permeability. Electroporation is used in medicine, biotechnology, and food processing. Recently, as an alternative to electroporation by PEF, Pulsed ElectroMagnetic Fields (PEMF) application causing similar biological effects was suggested. Since induced electric field in PEMF however is 2–3 magnitudes lower than in PEF electroporation, the membrane permeabilization mechanism remains hypothetical. We have designed pilot experiments where Saccharomyces cerevisiae and Candida lusitaniae cells were subjected to single 100–250 μs electrical pulse of 800 V with and without concomitant delivery of magnetic pulse (3, 6 and 9 T). As expected, after the PEF pulses only the number of Propidium Iodide (PI) fluorescent cells has increased, indicative of membrane permeabilization. We further show that single sub-millisecond magnetic field pulse did not cause detectable poration of yeast. Concomitant exposure of cells to pulsed electric (PEF) and magnetic field (PMF) however resulted in the increased number PI fluorescent cells and reduced viability. Our results show increased membrane permeability by PEF when combined with magnetic field pulse, which can explain electroporation at considerably lower electric field strengths induced by PEMF compared to classical electroporation.

  19. Cosmological Magnetic Fields

    CERN Document Server

    Kunze, Kerstin E

    2013-01-01

    Magnetic fields are observed on nearly all scales in the universe, from stars and galaxies upto galaxy clusters and even beyond. The origin of cosmic magnetic fields is still an open question, however a large class of models puts its origin in the very early universe. A magnetic dynamo amplifying an initial seed magnetic field could explain the present day strength of the galactic magnetic field. However, it is still an open problem how and when this initial magnetic field was created. Observations of the cosmic microwave background (CMB) provide a window to the early universe and might therefore be able to tell us whether cosmic magnetic fields are of primordial, cosmological origin and at the same time constrain its parameters. We will give an overview of the observational evidence of large scale magnetic fields, describe generation mechanisms of primordial magnetic fields and possible imprints in the CMB.

  20. Mechanism of spin crossover in LaCoO3 resolved by shape magnetostriction in pulsed magnetic fields.

    Science.gov (United States)

    Rotter, M; Wang, Z-S; Boothroyd, A T; Prabhakaran, D; Tanaka, A; Doerr, M

    2014-11-11

    In the scientific description of unconventional transport properties of oxides (spin-dependent transport, superconductivity etc.), the spin-state degree of freedom plays a fundamental role. Because of this, temperature- or magnetic field-induced spin-state transitions are in the focus of solid-state physics. Cobaltites, e.g. LaCoO3, are prominent examples showing these spin transitions. However, the microscopic nature of the spontaneous spin crossover in LaCoO3 is still controversial. Here we report magnetostriction measurements on LaCoO3 in magnetic fields up to 70 T to study the sharp, field-induced transition at Hc ≈ 60 T. Measurements of both longitudinal and transversal magnetostriction allow us to separate magnetovolume and magnetodistortive changes. We find a large increase in volume, but only a very small increase in tetragonal distortion at Hc. The results, supported by electronic energy calculations by the configuration interaction cluster method, provide compelling evidence that above Hc LaCoO3 adopts a correlated low spin/high spin state.

  1. Mechanism of spin crossover in LaCoO3 resolved by shape magnetostriction in pulsed magnetic fields

    Science.gov (United States)

    Rotter, M.; Wang, Z.-S.; Boothroyd, A. T.; Prabhakaran, D.; Tanaka, A.; Doerr, M.

    2014-11-01

    In the scientific description of unconventional transport properties of oxides (spin-dependent transport, superconductivity etc.), the spin-state degree of freedom plays a fundamental role. Because of this, temperature- or magnetic field-induced spin-state transitions are in the focus of solid-state physics. Cobaltites, e.g. LaCoO3, are prominent examples showing these spin transitions. However, the microscopic nature of the spontaneous spin crossover in LaCoO3 is still controversial. Here we report magnetostriction measurements on LaCoO3 in magnetic fields up to 70 T to study the sharp, field-induced transition at Hc ~ 60 T. Measurements of both longitudinal and transversal magnetostriction allow us to separate magnetovolume and magnetodistortive changes. We find a large increase in volume, but only a very small increase in tetragonal distortion at Hc. The results, supported by electronic energy calculations by the configuration interaction cluster method, provide compelling evidence that above Hc LaCoO3 adopts a correlated low spin/high spin state.

  2. Synchrotron Applications of High Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This workshop aims at discussing the scientific potential of X-ray diffraction and spectroscopy in magnetic fields above 30 T. Pulsed magnetic fields in the range of 30 to 40 T have recently become available at Spring-8 and the ESRF (European synchrotron radiation facility). This document gathers the transparencies of the 6 following presentations: 1) pulsed magnetic fields at ESRF: first results; 2) X-ray spectroscopy and diffraction experiments by using mini-coils: applications to valence state transition and frustrated magnet; 3) R{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4}: an ideal system to be studied in X-ray under high magnetic field?; 4) high field studies at the Advanced Photon Source: present status and future plans; 5) synchrotron X-ray diffraction studies under extreme conditions; and 6) projects for pulsed and steady high magnetic fields at the ESRF.

  3. Consequences of the magnetic field, sonic and radiofrequency waves and intense pulsed light on the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Patricia Froes; Costa, Iris do Ceu Clara; Brandao-Neto, Jose; Medeiros, Aldo da Cunha [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-graduacao em Ciencias da Saude; Santos-Filho, Sebastiao David; Adenilson de Souza da Fonseca; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Ariel Ronzio, Oscar [Universidad de Buenos Aires (Argentina); Bonelli, Ludmila [Universidade Salgado de Oliveira, Belo Horizonte, MG (Brazil)

    2007-09-15

    Sources of magnetic field, radiofrequency and audible sonic waves and pulsed light have been used in physiotherapy to treat different disorders. In nuclear medicine, blood constituents(Bl-Co) are labeled with technetium-99m ({sup 99m}Tc) are used. This study evaluated the consequences of magnetic field, radiofrequency and audible sonic waves and intense pulsed light sources on the labeling of Bl-Co with {sup 99m}Tc. Blood from Wistar rats was exposed to the cited sources. The labeling of Bl-Co with {sup 99m}Tc was performed. Blood not exposed to the physical agents was used(controls). Data showed that the exposure to the different studied sources did not alter significantly (p>0.05) the labeling of Bl-Co. Although the results were obtained with animals, the data suggest that no alteration on examinations performed with Bl-Co labeled with {sup 99m}Tc after exposition to the cited agents. The biological consequences associated with these agents would be not capable to interfere with some properties of the Bl-Co. (author)

  4. Electric field control of Skyrmions in magnetic nanodisks

    Science.gov (United States)

    Nakatani, Y.; Hayashi, M.; Kanai, S.; Fukami, S.; Ohno, H.

    2016-04-01

    The control of magnetic Skyrmions confined in a nanometer scale disk using electric field pulses is studied by micromagnetic simulation. A stable Skyrmion can be created and annihilated by an electric field pulse depending on the polarity of the electric field. Moreover, the core direction of the Skyrmion can be switched using the same electric field pulses. Such creation and annihilation of Skyrmions, and its core switching do not require any magnetic field and precise control of the pulse length. This unconventional manipulation of magnetic texture using electric field pulses allows a robust way of controlling magnetic Skyrmions in nanodiscs, a path toward building ultralow power memory devices.

  5. Cryosurgery with pulsed electric fields.

    Science.gov (United States)

    Daniels, Charlotte S; Rubinsky, Boris

    2011-01-01

    This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF) are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF) was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused PEFs could be used to

  6. Cryosurgery with pulsed electric fields.

    Directory of Open Access Journals (Sweden)

    Charlotte S Daniels

    Full Text Available This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused

  7. Cryosurgery with Pulsed Electric Fields

    Science.gov (United States)

    Daniels, Charlotte S.; Rubinsky, Boris

    2011-01-01

    This study explores the hypothesis that combining the minimally invasive surgical techniques of cryosurgery and pulsed electric fields will eliminate some of the major disadvantages of these techniques while retaining their advantages. Cryosurgery, tissue ablation by freezing, is a well-established minimally invasive surgical technique. One disadvantage of cryosurgery concerns the mechanism of cell death; cells at high subzero temperature on the outer rim of the frozen lesion can survive. Pulsed electric fields (PEF) are another minimally invasive surgical technique in which high strength and very rapid electric pulses are delivered across cells to permeabilize the cell membrane for applications such as gene delivery, electrochemotherapy and irreversible electroporation. The very short time scale of the electric pulses is disadvantageous because it does not facilitate real time control over the procedure. We hypothesize that applying the electric pulses during the cryosurgical procedure in such a way that the electric field vector is parallel to the heat flux vector will have the effect of confining the electric fields to the frozen/cold region of tissue, thereby ablating the cells that survive freezing while facilitating controlled use of the PEF in the cold confined region. A finite element analysis of the electric field and heat conduction equations during simultaneous tissue treatment with cryosurgery and PEF (cryosurgery/PEF) was used to study the effect of tissue freezing on electric fields. The study yielded motivating results. Because of decreased electrical conductivity in the frozen/cooled tissue, it experienced temperature induced magnified electric fields in comparison to PEF delivered to the unfrozen tissue control. This suggests that freezing/cooling confines and magnifies the electric fields to those regions; a targeting capability unattainable in traditional PEF. This analysis shows how temperature induced magnified and focused PEFs could be used to

  8. Magnetic Field Grid Calculator

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Magnetic Field Properties Calculator will computes the estimated values of Earth's magnetic field(declination, inclination, vertical component, northerly...

  9. The Earth's Magnetic Field

    OpenAIRE

    Edda Lína Gunnarsdóttir 1988

    2012-01-01

    The Earth's magnetic field is essential for life on Earth, as we know it, to exist. It forms a magnetic shield around the planet, protecting it from high energy particles and radiation from the Sun, which can cause damage to life, power systems, orbiting satellites, astronauts and spacecrafts. This report contains a general overview of the Earth's magnetic field. The different sources that contribute to the total magnetic field are presented and the diverse variations in the field are describ...

  10. Ultrafast imprinting of topologically protected magnetic textures via pulsed electrons

    Science.gov (United States)

    Schäffer, A. F.; Dürr, H. A.; Berakdar, J.

    2017-07-01

    Short electron pulses are demonstrated to trigger and control magnetic excitations, even at low electron current densities. We show that the tangential magnetic field surrounding a picosecond electron pulse can imprint topologically protected magnetic textures such as skyrmions in a sample with a residual Dzyaloshinskii-Moriya spin-orbital coupling. Characteristics of the created excitations such as the topological charge can be steered via the duration and the strength of the electron pulses. The study points to a possible way for a spatiotemporally controlled generation of skyrmionic excitations.

  11. Self-diffusion of electrolyte species in model battery electrodes using Magic Angle Spinning and Pulsed Field Gradient Nuclear Magnetic Resonance

    Science.gov (United States)

    Tambio, Sacris Jeru; Deschamps, Michaël; Sarou-Kanian, Vincent; Etiemble, Aurélien; Douillard, Thierry; Maire, Eric; Lestriez, Bernard

    2017-09-01

    Lithium-ion batteries are electrochemical storage devices using the electrochemical activity of the lithium ion in relation to intercalation compounds owing to mass transport phenomena through diffusion. Diffusion of the lithium ion in the electrode pores has been poorly understood due to the lack of experimental techniques for measuring its self-diffusion coefficient in porous media. Magic-Angle Spinning, Pulsed Field Gradient, Stimulated-Echo Nuclear Magnetic Resonance (MAS-PFG-STE NMR) was used here for the first time to measure the self-diffusion coefficients of the electrolyte species in the LP30 battery electrolyte (i.e. a 1 M solution of LiPF6 dissolved in 1:1 Ethylene Carbonate - Dimethyl Carbonate) in model composites. These composite electrodes were made of alumina, carbon black and PVdF-HFP. Alumina's magnetic susceptibility is close to the measured magnetic susceptibility of the LP30 electrolyte thereby limiting undesirable internal field gradients. Interestingly, the self-diffusion coefficient of lithium ions decreases with increasing carbon content. FIB-SEM was used to describe the 3D geometry of the samples. The comparison between the reduction of self-diffusion coefficients as measured by PFG-NMR and as geometrically derived from FIB/SEM tortuosity values highlights the contribution of specific interactions at the material/electrolyte interface on the lithium transport properties.

  12. Weibel instability in the field of a short laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Grishkov, V. E.; Uryupin, S. A. [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

    2013-03-15

    The growth rate of Weibel instability in a plasma interacting with a high-frequency pulse with a duration less or comparable with the electron mean free time is determined. The growth rate is shown to decrease with decreasing pulse duration. It is found that instability can develop after the short pulse is switched off and the generated magnetic field no longer affects electron motion in the high-frequency field.

  13. Treatment Pulse Application for Magnetic Stimulation

    Directory of Open Access Journals (Sweden)

    Sun-Seob Choi

    2011-01-01

    Full Text Available Treatment and diagnosis can be made in difficult areas simply by changing the output pulse form of the magnetic stimulation device. However, there is a limitation in the range of treatments and diagnoses of a conventional sinusoidal stimulation treatment pulse because the intensity, width, and form of the pulse must be changed according to the lesion type. This paper reports a multidischarge method, where the stimulation coils were driven in sequence via multiple switching control. The limitation of the existing simple sinusoidal pulse form could be overcome by changing the intensity, width, and form of the pulse. In this study, a new sequential discharge method was proposed to freely alter the pulse width. The output characteristics of the stimulation treatment pulse were examined according to the trigger signal delay applied to the switch at each stage by applying a range of superposition pulses to the magnetic simulation device, which is widely used in industry and medicine.

  14. On the modulation effect of pulsing and static magnetic fields and mechanical vibrations on barley seed hydration.

    Science.gov (United States)

    Amyan, Armine; Ayrapetyan, Sinerik

    2004-01-01

    The changes of wet and dry weights of barley seed in different periods of swelling were studied in seeds treated with Extremely Low Frequency Electromagnetic Fields (ELF EMF), Static Magnetic Fields (SMF) and Mechanical Vibrations (MV) in cold (4 degrees C) and warm (20 degrees C) distilled water as well as in seeds non-treated (control). The metabolic dependent seed hydration, dry weight loss and water binding in seed were modulated by preliminary EMF, SMF and MV-induced treatment of distilled water. The specific electrical conductivity (SEC) of control and treated distilled water was measured before the seed incubation. Frequency and intensity "windows" (i.e. range of frequency or intensity) for the effect of EMF, MV and SMF (correspondingly) on seed hydration, solubility and water binding in seed were studied. These "windows" were different in various phases of seed swelling. It is suggested that water structure modification is the result of valence angle changes (SMF and EMF) and dipole molecules vibration (EMF and MV) has different effects on the process of hydration, solubility and water binding in seed. These results are important from the point of understanding the mechanisms of the biological effect of EMF, as well as from the point of agriculture.

  15. Magnetic fields in galaxies

    CERN Document Server

    Beck, Rainer

    2013-01-01

    Most of the visible matter in the Universe is ionized, so that cosmic magnetic fields are quite easy to generate and due to the lack of magnetic monopoles hard to destroy. Magnetic fields have been measured in or around practically all celestial objects, either by in-situ measurements of spacecrafts or by the electromagnetic radiation of embedded cosmic rays, gas or dust. The Earth, the Sun, solar planets, stars, pulsars, the Milky Way, nearby galaxies, more distant (radio) galaxies, quasars and even intergalactic space in clusters of galaxies have significant magnetic fields, and even larger volumes of the Universe may be permeated by "dark" magnetic fields. Information on cosmic magnetic fields has increased enormously as the result of the rapid development of observational methods, especially in radio astronomy. In the Milky Way, a wealth of magnetic phenomena was discovered, which are only partly related to objects visible in other spectral ranges. The large-scale structure of the Milky Way's magnetic fie...

  16. 600-T Magnetic Fields due to Cold Electron Flow in a simple Cu-Coil irradiated by High Power Laser pulses

    CERN Document Server

    Zhu, Baojun; Yuan, Dawei; Li, Yanfei; Li, Fang; Liao, Guoqian; Zhao, Jiarui; Zhong, Jiayong; Xue, Feibiao; Wei, Huigang; Zhang, Kai; Han, Bo; Pei, Xiaoxing; Liu, Chang; Zhang, Zhe; Wang, Weimin; Zhu, Jianqiang; Zhao, Gang; Zhang, Jie

    2015-01-01

    A new simple mechanism due to cold electron flow to produce strong magnetic field is proposed. A 600-T strong magnetic field is generated in the free space at the laser intensity of 5.7x10^15 Wcm^-2. Theoretical analysis indicates that the magnetic field strength is proportional to laser intensity. Such a strong magnetic field offers a new experimental test bed to study laser-plasma physics, in particular, fast-ignition laser fusion research and laboratory astrophysics.

  17. The Juno Magnetic Field Investigation

    DEFF Research Database (Denmark)

    Connerney, J. E. P.; Benn, Mathias; Bjarnø, Jonas Bækby

    2017-01-01

    The Juno Magnetic Field investigation (MAG) characterizes Jupiter’s planetary magnetic field and magnetosphere, providing the first globally distributed and proximate measurements of the magnetic field of Jupiter. The magnetic field instrumentation consists of two independent magnetometer sensor ...

  18. Mixture diffusion of adsorbed organic compounds in metal-organic frameworks as studied by magic-angle spinning pulsed-field gradient nuclear magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Gratz, Marcel; Hertel, Stefan; Wehring, Markus; Stallmach, Frank [Faculty of Physics and Earth Science, University of Leipzig, Linnestrasse 5, 04103 Leipzig (Germany); Galvosas, Petrik, E-mail: petrik.galvosas@vuw.ac.nz [MacDiarmid Institute for Advanced Materials and Nanotechnology, SCPS, Victoria University of Wellington, 6012 Wellington (New Zealand)

    2011-04-15

    The magic-angle spinning (MAS) and pulsed-field gradient nuclear magnetic resonance (PFG NMR) techniques have been combined using a commercially available microimaging system providing a gradient in the magic-angle direction of up to {+-}2.6 T m{sup -1}, together with a narrow bore MAS probe. By narrowing the spectral linewidths, detection of the single and mixed molecular species adsorbed in porous material and their respective mobilities becomes possible. Here, we report on protocols for MAS PFG NMR measurements, new methods for the indispensable sample alignment along the MAS rotational axis and gradient direction and first experimental results of diffusion studies on n-hexane and benzene adsorbed in the metal-organic framework MOF-5.

  19. The First Magnetic Fields

    CERN Document Server

    Widrow, Lawrence M; Schleicher, Dominik; Subramanian, Kandaswamy; Tsagas, Christos G; Treumann, Rudolf A

    2011-01-01

    We review current ideas on the origin of galactic and extragalactic magnetic fields. We begin by summarizing observations of magnetic fields at cosmological redshifts and on cosmological scales. These observations translate into constraints on the strength and scale magnetic fields must have during the early stages of galaxy formation in order to seed the galactic dynamo. We examine mechanisms for the generation of magnetic fields that operate prior during inflation and during subsequent phase transitions such as electroweak symmetry breaking and the quark-hadron phase transition. The implications of strong primordial magnetic fields for the reionization epoch as well as the first generation of stars is discussed in detail. The exotic, early-Universe mechanisms are contrasted with astrophysical processes that generate fields after recombination. For example, a Biermann-type battery can operate in a proto-galaxy during the early stages of structure formation. Moreover, magnetic fields in either an early genera...

  20. Trapped field properties of a Y–Ba–Cu–O bulk by pulsed field magnetization using a split coil inserted by iron yokes with various geometries and electromagnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, K., E-mail: t2216017@iwate-u.ac.jp [Department of Physical Science and Materials Engineering, Faculty of Science and Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Ainslie, M.D. [Bulk Superconductivity Group, Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ (United Kingdom); Fujishiro, H.; Naito, T. [Department of Physical Science and Materials Engineering, Faculty of Science and Engineering, Iwate University, 4-3-5 Ueda, Morioka 020-8551 (Japan); Shi, Y-H.; Cardwell, D.A. [Bulk Superconductivity Group, Department of Engineering, University of Cambridge, Trumpington Street, Cambridge CB2 1PZ (United Kingdom)

    2017-05-15

    Highlights: • The trapped field characteristics of a standard Y–Ba–Cu–O bulk magnetized by PFM was investigated using a split coil with three kinds of iron yokes inserted in the bores of coil,both experimentally and numerically. • Numerical results encourage better understanding of the role of yoke, including the typical behavior of the magnetic flux, such as a flux jump during PFM. • A higher saturation magnetic flux density of the yoke material was effective to reduce flux flow in the descending stage of the pulsed field. • A conductivity of the yoke material also acts to reduce the velocity of the flux intruding the bulk because of eddy currents that flow in the yoke that oppose the magnetization, which reduces the temperature rise in the bulk. - Abstract: We have investigated, both experimentally and numerically, the trapped field characteristics of a standard Y–Ba–Cu–O bulk of 30 mm in diameter and 14 mm in thickness magnetized by pulsed field magnetization (PFM) using a split coil, in which three kinds of iron yoke are inserted in the bore of the coil: soft iron with a flat surface, soft iron with a taper, and permendur (50Fe + 50Co alloy) with a flat surface. The highest trapped field, B{sub Tmax}, of 2.93 T was achieved at 40 K in the case of the permendur yoke, which was slightly higher than that obtained for the flat soft iron or the tapered soft iron yokes, and was much higher than 2.20 T in the case without the yoke. The insertion effect of the yoke on the trapped field characteristics was also investigated using numerical simulations. The results suggest that the saturation magnetic flux density, B{sub sat}, of the yoke acts to reduce the flux flow due to its hysteretic magnetization curve and the higher electrical conductivity, σ, of the yoke material also acts to suppress the flux increase rate. A flux jump (or flux leap) can be reproduced in the ascending stage of PFM using numerical simulation, using an assumption of relatively

  1. Pulsed magnetic field versus ultrasound in the treatment of postnatal carpal tunnel syndrome: A randomized controlled trial in the women of an Egyptian population

    Directory of Open Access Journals (Sweden)

    Dalia M. Kamel

    2017-01-01

    Full Text Available The aim of this study was to compare the effects of pulsed electromagnetic field versus pulsed ultrasound in treating patients with postnatal carpal tunnel syndrome. The study was a randomized, double-blinded trial. Forty postnatal female patients with idiopathic carpal tunnel syndrome were divided randomly into two equal groups. One group received pulsed electromagnetic field, with nerve and tendon gliding exercises for the wrist, three times per week for four weeks. The other group received pulsed ultrasound and the same wrist exercises. Pain level, sensory and motor distal latencies and conduction velocities of the median nerve, functional status scale and hand grip strength were assessed pre- and post-treatment. There was a significant decrease (P  0.05. In conclusion, while the symptoms were alleviated in both groups, pulsed electromagnetic field was more effective than pulsed ultrasound in treating postnatal carpal tunnel syndrome.

  2. Transport properties of Na doped La sub 1 sub - sub x Ca sub x sub - sub y Na sub y MnO sub 3 measured in a pulsed magnetic field

    CERN Document Server

    Bhattacharya, S; Pal, S; Chatterjee, P; Mukherjee, R K; Chaudhuri, B K

    2002-01-01

    Temperature-dependent magnetization and magnetoresistance of the Na doped La sub 1 sub - sub x Ca sub x sub sub - sub y Na sub y MnO sub 3 type samples with x=0.3 and 0 T sub p up to 320 K) conductivity data satisfy the variable range hopping (VRH) model. For T > 320 the small polaron hopping model is more appropriate than the VRH model. Even with a very small change of y, the density of states at the Fermi level N(E sub F) changes considerably. The resistivity of these materials measured under pulsed and continuous DC magnetic fields behaves in an identical fashion. The relaxation time (decay time of the magnetic pulse within the sample) varies with field strength, which indicates that, with a change of magnetic field, the ordering of spin in the ferromagnetic regime changes.

  3. Relativistic dynamics of an electron in a pulse of laser light with propagation along of an external magnetic field; Dinamica relativista de un electron en un pulso de luz laser con propagacion a lo largo de un campo magnetico externo

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, F. [UAEM, Facultad de Ciencias, 50000 Toluca, Estado de Mexico (Mexico); Ondarza, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The exact solution for the movement of a charged particle in the interaction of an electromagnetic pulse elliptically polarized spreading along a static and homogeneous magnetic field is obtained starting from the equation of force. The solution method allows to solve, in terms of the phase, the trajectory of an accelerated particle by a pulse of arbitrary width and modulated by an encircling in Gaussian form. The reported solutions in this work have diverse applications in the laser-plasma interaction physics. (Author)

  4. Organic magnetic field sensor

    Energy Technology Data Exchange (ETDEWEB)

    McCamey, Dane; Boehme, Christoph

    2017-01-24

    An organic, spin-dependent magnetic field sensor (10) includes an active stack (12) having an organic material with a spin-dependence. The sensor (10) also includes a back electrical contact (14) electrically coupled to a back of the active stack (12) and a front electrical contact (16) electrically coupled to a front of the active stack (12). A magnetic field generator (18) is oriented so as to provide an oscillating magnetic field which penetrates the active stack (12).

  5. Circularly Polarized Attosecond Pulses and Molecular Atto-Magnetism

    CERN Document Server

    Bandrauk, Andre D

    2014-01-01

    Various schemes are presented for the generation of circularly polarized molecular high-order harmonic generation (MHOHG) from molecules. In particular it is shown that combinations of counter-rotating circularly polarized pulses produce the lowest frequency Coriolis forces with the highest frequency recollisions, thus generating new harmonics which are the source of circular polarized attosecond pulses (CPAPs). These can be used to generate circularly polarized electronic currents in molecular media on attosecond time scale. Molecular attosecond currents allow then for the generation of ultrashort magnetic field pulses on the attosecond time scale, new tools for molecular atto-magnetism (MOLAM).

  6. Development of reliable 70 T pulsed magnets

    Science.gov (United States)

    Lagutin, A.; Rosseel, K.; Herlach, F.; Vanacken, J.; Bruynseraede, Y.

    2003-12-01

    A capacitor-driven pulsed magnet coil has been designed to generate fields in the 70-75 T range, with a life expectancy of at least 100 pulses, thus qualifying as a '75 T class user magnet'. The bore is 10 mm and the rise time used in our experiments is 4 ms. The coil consists of two coaxial sections: the inner section, where stresses are highest, is made with CuNb microcomposite wire and optimized Zylon reinforcement; the outer section is made with soft copper and glass fibre composite. In the inner section, the stress in each layer is self-contained, while the stresses induced in the outer section are transmitted to a thick shell made from steel and carbon fibre composite. The cross section of the copper wires is adjusted to redistribute the heating evenly between the inner and the outer section. Another innovative design feature is a system for axial compression that can be easily retightened during coil training. Two nearly identical coils were manufactured and tested to 72 T this is a limit imposed due to overheating when using our 10 kV, 0.5 MJ capacitor bank (at an energy of 380 kJ). At 75 T, the calculated von Mises stress in the Zylon composite is 2.6 GPa, well below the UTS of more than 3 GPa, and the CuNb wire is still in an elastic state.

  7. Comparative Study on the Grain Refinement of Al-Si Alloy Solidified under the Impact of Pulsed Electric Current and Travelling Magnetic Field

    Directory of Open Access Journals (Sweden)

    Yunhu Zhang

    2016-07-01

    Full Text Available It is high of commercial importance to generate the grain refinement in alloys during solidification by means of electromagnetic fields. Two typical patterns of electromagnetic fields, pulsed electric currents (ECP and traveling magnetic field (TMF, are frequently employed to produce the finer equiaxed grains in solidifying alloys. Various mechanisms were proposed to understand the grain refinement in alloys caused by ECP and TMF. In this paper, a comparative study is carried out in the same solidification regime to investigate the grain refinement of Al-7 wt. %Si alloy driven by ECP and TMF. Experimental results show that the application of ECP or TMF can cause the same grain refinement occurrence period, during which the refinement of primary Al continuously occurs. In addition, the related grain refinement mechanisms are reviewed and discussed, which shows the most likely one caused by ECP and TMF is the promoted dendrite fragmentation as the result of the ECP-induced or TMF-induced forced flow. It suggests that the same grain refinement process in alloys is provoked when ECP and TMF are applied in the same solidification regime, respectively.

  8. High-performance pulsed magnets: Theory, design and construction

    Science.gov (United States)

    Li, Liang

    This thesis is an in-depth study of the design and construction of coils for pulsed magnets energised by a capacitor bank, including mathematical modelling and testing of the coils. The magnetic field generated by solenoid magnets with homogeneous and non-homogenous current distribution is calculated with the elliptical integral method. Coupled partial differential equations for magnetic and thermal diffusion and the electric circuits are solved numerically to calculate the pulse shape and the heating in a pulsed magnet. The calculations are in good agreement with test results for a large range of different coils; this provides useful insights for optimised coil design. Stresses and strains in the mid-plane of the coil are analytically calculated by solving the system of equations describing the displacement in each layer of the coil. Non-linear stress-strain characteristics and the propagation of the plastic deformation are taken into account by sub- dividing each layer of the coil in the radial direction and changing the elastic-plastic matrix at each transition point. Conductors, insulating materials and techniques used for pulsed magnets are discussed in detail. More than 80 pulsed magnets with optimised combinations of conductors and reinforcements have been built and tested, with peak fields in the range 45-73 T and a bore size from 8 mm-35 mm. The pulse duration is of the order of 10 milliseconds. A dual stage pulsed magnet for use at a free electron laser has been developed. This has a rise time of 10 microseconds and enables magneto-optical experiments in a parameter range previously inaccessible to condensed matter physicists. The joint of superconducting cables can be modelled by means of distributed circuit elements that characterise current diffusion.

  9. High magnetic fields science and technology

    CERN Document Server

    Miura, Noboru

    2003-01-01

    This three-volume book provides a comprehensive review of experiments in very strong magnetic fields that can only be generated with very special magnets. The first volume is entirely devoted to the technology of laboratory magnets: permanent, superconducting, high-power water-cooled and hybrid; pulsed magnets, both nondestructive and destructive (megagauss fields). Volumes 2 and 3 contain reviews of the different areas of research where strong magnetic fields are an essential research tool. These volumes deal primarily with solid-state physics; other research areas covered are biological syst

  10. Trapped field of 1.1 T without flux jumps in an MgB2 bulk during pulsed field magnetization using a split coil with a soft iron yoke

    Science.gov (United States)

    Fujishiro, H.; Mochizuki, H.; Ainslie, M. D.; Naito, T.

    2016-08-01

    MgB2 superconducting bulks have promising potential as trapped field magnets. We have achieved a trapped field of B z = 1.1 T on a high-J c MgB2 bulk at 13 K without flux jumps by pulsed field magnetization (PFM) using a split-type coil with a soft iron yoke, which is a record-high trapped field by PFM for bulk MgB2 to date. The flux jumps, which frequently took place using a solenoid-type coil during PFM, were avoided by using the split-type coil, and the B z value was enhanced by the insertion of soft iron yoke. The flux dynamics and heat generation/propagation were analyzed during PFM using a numerical simulation, in which the magnetic flux intruded and attenuated slowly in the bulk and tended to align along the axial direction due to the presence of soft iron yoke. The advantages of the split-type coil and the simultaneous use of a soft iron yoke are discussed.

  11. Pulsed laser deposition and characterization of Alnico5 magnetic films

    Energy Technology Data Exchange (ETDEWEB)

    Butt, M.Z., E-mail: mzbutt49@yahoo.com [Department of Physics, GC University, Lahore 54000 (Pakistan); Ali, Dilawar [Department of Physics, GC University, Lahore 54000 (Pakistan); Ahmad, Fayyaz [Department of Physics, University of Engineering and Technology, Lahore 54890 (Pakistan); Magnetophotonics Research Laboratory, Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2013-09-01

    Alnico5 films were deposited by pulsed laser deposition on glass substrate at room temperature under a vacuum ∼10{sup −3} Torr in the absence and in the presence of 500 Oe external transverse magnetic field applied on the plasma plume during film deposition. For this purpose, Nd:YAG laser was employed to ablate the Alnico5 target. The ablated material was deposited on glass substrate placed at a distance of 2 cm from the target. The structural and magnetic properties of the film were analyzed by X-ray diffraction, atomic force microscope, and vibrating sample magnetometer. X-ray diffraction patterns showed that the Alnico5 films were amorphous in nature. Atomic force microscopy revealed that the Alnico5 film deposited in absence of external magnetic field has larger root-mean-square roughness value (60.2 nm) than the magnetically deposited film (42.9 nm). Vibrating sample magnetometer measurements showed that the in-plane saturation magnetization of Alnico5 film deposited in the presence of external magnetic field increases by 32% as compared to that for the film deposited in the absence of external magnetic field. However, the out-of-plane saturation magnetization was almost independent of the external magnetic field. In magnetically deposited film, there is in-plane anisotropy parallel to the applied external magnetic field.

  12. Effects of pulsed electric field on ULQ and RFP plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M. [Iwate Univ., Morioka (Japan). Faculty of Engineering; Saito, K.; Suzuki, T. [and others

    1997-12-31

    Dynamo activity and self-organization processes are investigated using the application of pulsed poloidal and toroidal electric fields on ULQ and RFP plasmas. Synchronized to the application of the pulsed electric fields, the remarkable responses of the several plasma parameters are observed. The plasma has a preferential magnetic field structure, and the external perturbation activates fluctuation to maintain the structure through dynamo effect. This process changes the total dissipation with the variation of magnetic helicity in the system, showing that self organization accompanies an enhanced dissipation. (author)

  13. Analytical solution of precessional switching in nanomagnets driven by hard-axis field pulses

    Energy Technology Data Exchange (ETDEWEB)

    D' Aquino, M., E-mail: daquino@uniparthenope.it [Engineering Department, University of Naples “Parthenope”, 80143 Naples (Italy); Perna, S.; Serpico, C. [DIETI, University of Naples Federico II, 80125 Naples (Italy); Bertotti, G. [Istituto Nazionale di Ricerca Metrologica, 10135 Torino (Italy); Mayergoyz, I.D. [ECE Department and UMIACS, University of Maryland, College Park, MD, 20742 (United States); Quercia, A. [DIETI, University of Naples Federico II, 80125 Naples (Italy)

    2016-04-01

    The precessional switching process of a magnetic nanoparticle subject to external field pulses applied along the hard-axis is considered. The critical field pulse amplitude necessary to realize the switching is determined. Then, the analytical solution of magnetization switching dynamics is derived in the lossless limit by using elliptic functions. Moreover, expressions for the field pulse duration tolerances which guarantee successful switching are also obtained. The theoretical predictions are verified by macrospin numerical simulations of ultra-fast magnetization switching.

  14. Consequences of the magnetic field, sonic and radiofrequency waves and intense pulsed light on the labeling of blood constituents with technetium-99m

    Directory of Open Access Journals (Sweden)

    Patricia Froes Meyer

    2007-09-01

    Full Text Available Sources of magnetic field, radiofrequency and audible sonic waves and pulsed light have been used in physiotherapy to treat different disorders. In nuclear medicine, blood constituents(Bl-Co are labeled with technetium-99m (99mTc are used. This study evaluated the consequences of magnetic field, radiofrequency and audible sonic waves and intense pulsed light sources on the labeling of Bl-Co with 99mTc. Blood from Wistar rats was exposed to the cited sources. The labeling of Bl-Co with 99mTc was performed. Blood not exposed to the physical agents was used(controls. Data showed that the exposure to the different studied sources did not alter significantly (p>0.05 the labeling of Bl-Co. Although the results were obtained with animals, the data suggest that no alteration on examinations performed with Bl-Co labeled with 99mTc after exposition to the cited agents. The biological consequences associated with these agents would be not capable to interfere with some properties of the Bl-Co.Fontes de campo magnético, ondas sonoras audíveis e de radiofreqüência e luz intensa pulsada são usadas para o tratamento de doenças. Constituintes sangüíneos(CS marcados com tecnécio-99m(99mTc são utilizados na medicina nuclear. Esse trabalho avaliou as consequências de fontes de campo magnético, ondas sonoras audíveis e de radiofreqüência e luz intensa pulsada na marcação de CS com 99mTc. Sangue de ratos Wistar foi exposto às fontes citadas. A marcação de CS com 99mTc foi realizada. Sangue não exposto foram utilizadas(controle. Resultados mostraram que os agentes físicos estudados não alteraram significativamente (p>0.05 a radiomarcação de CS. Apesar terem sido obtidos com sangue de animais, os resultados sugerem que nenhuma alteração nos exames realizados com constituintes sangüíneos com 99mTc em medicina nuclear ocorreria após a exposição às fontes avaliadas. As consequências biológicas associadas a esses agentes não seriam

  15. Repetitive transcranial magnetic stimulator with controllable pulse parameters

    Science.gov (United States)

    Peterchev, Angel V.; Murphy, David L.; Lisanby, Sarah H.

    2011-06-01

    The characteristics of transcranial magnetic stimulation (TMS) pulses influence the physiological effect of TMS. However, available TMS devices allow very limited adjustment of the pulse parameters. We describe a novel TMS device that uses a circuit topology incorporating two energy storage capacitors and two insulated-gate bipolar transistor (IGBT) modules to generate near-rectangular electric field pulses with adjustable number, polarity, duration, and amplitude of the pulse phases. This controllable pulse parameter TMS (cTMS) device can induce electric field pulses with phase widths of 10-310 µs and positive/negative phase amplitude ratio of 1-56. Compared to conventional monophasic and biphasic TMS, cTMS reduces energy dissipation up to 82% and 57% and decreases coil heating up to 33% and 41%, respectively. We demonstrate repetitive TMS trains of 3000 pulses at frequencies up to 50 Hz with electric field pulse amplitude and width variability less than the measurement resolution (1.7% and 1%, respectively). Offering flexible pulse parameter adjustment and reduced power consumption and coil heating, cTMS enhances existing TMS paradigms, enables novel research applications and could lead to clinical applications with potentially enhanced potency.

  16. Switching of antiferromagnetic chains with magnetic pulses

    Science.gov (United States)

    Tao, Kun; Polyakov, Oleg P.; Stepanyuk, Valeri S.

    2016-04-01

    Recent experimental studies have demonstrated the possibility of information storage in short antiferromagnetic chains on an insulator substrate [S. Loth et al., Science 335, 196 (2012), 10.1126/science.1214131]. Here, using the density functional theory and atomistic spin dynamics simulations, we show that a local magnetic control of such chains with a magnetic tip and magnetic pulses can be used for fast switching of their magnetization. Furthermore, by changing the position of the tip one can engineer the magnetization dynamics of the chains.

  17. Pulsed electric field increases reproduction.

    Science.gov (United States)

    Panagopoulos, Dimitris J

    2016-01-01

    Purpose To study the effect of pulsed electric field - applied in corona discharge photography - on Drosophila melanogaster reproduction, possible induction of DNA fragmentation, and morphological alterations in the gonads. Materials and methods Animals were exposed to different field intensities (100, 200, 300, and 400 kV/m) during the first 2-5 days of their adult lives, and the effect on reproductive capacity was assessed. DNA fragmentation during early- and mid-oogenesis was investigated by application of the TUNEL (Terminal deoxynucleotide transferase dUTP Nick End Labeling) assay. Sections of follicles after fixation and embedding in resins were observed for possible morphological/developmental abnormalities. Results The field increased reproduction by up to 30% by increasing reproductive capacity in both sexes. The effect increased with increasing field intensities. The rate of increase diminished at the strongest intensities. Slight induction of DNA fragmentation was observed exclusively in the nurse (predominantly) and follicle cells, and exclusively at the two most sensitive developmental stages, i.e., germarium and predominantly stage 7-8. Sections of follicles from exposed females at stages of early and mid-oogennesis other than germarium and stages 7-8 did not reveal abnormalities. Conclusions (1) The specific type of electric field may represent a mild stress factor, inducing DNA fragmentation and cell death in a small percentage of gametes, triggering the reaction of the animal's reproductive system to increase the rate of gametogenesis in order to compensate the loss of a small number of gametes. (2) The nurse cells are the most sensitive from all three types of egg chamber cells. (3) The mid-oogenesis checkpoint (stage 7-8) is more sensitive to this field than the early oogenesis one (germarium) in contrast to microwave exposure. (4) Possible therapeutic applications, or applications in increasing fertility, should be investigated.

  18. Directed cell movement in pulsed electric fields.

    Science.gov (United States)

    Franke, K; Gruler, H

    1994-01-01

    Human granulocytes exposed to pulsed electric guiding fields were investigated. The trajectories were determined from digitized pictures (phase contrast). The basic results are: (i) No directed response was induced by pulsed electric guiding fields having a zero averaged field. (ii) A directed response was induced by pulsed electric guiding fields having a non-zero averaged field. (iii) The directed response was enhanced for pulse sequences having a repetition time of 8 s. (iv) The lag-time between signal recognition and cellular response was 8-10 s. The results are discussed in the framework of a self-ignition model.

  19. Reducing Field Distortion in Magnetic Resonance Imaging

    Science.gov (United States)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  20. Magnetic study of a few antiferromagnets in very-strong pulsed fields (450 kOE); Etude magnetique de quelques antiferromagnetiques dans des champs pulses tres intenses (450 k OE)

    Energy Technology Data Exchange (ETDEWEB)

    Krebs, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-01-01

    In this thesis we describe a pulsed field device with which we obtain magnetization curves up to 450 kOE at all temperatures between 1. 6 and 300. We have studied the 'spin-flopping'(and therefore the anisotropy) in MnF{sub 2} versus temperature, below the Neel point. We have also studied the antiferromagnets MnSO{sub 4}. and MnSO{sub 4}.H{sub 2}O which have revealed saturation fields respectively of 250 kOE and 320 kOE. (author) [French] Ce memoire est consacre a la fabrication et a la mise au point d'un appareillage utilisant la decharge d'une batterie de condensateurs, afin de faire des mesures d'aimantation en champs pulses jusqu'a 450 kOE a toute temperature entre 1,6 K et 300 K. Nous avons etudie le deplacement de la transition de 'spin-flopping' dans MnF{sub 2} en fonction de la temperature et nous en avons deduit la variation de la constante d'anisotropie en fonction de T au-dessous du point de Neel. Nous avons egalement fait l'etude magnetique des antiferromagnetiques MnSO{sub 4} et MnSO{sub 4}.H{sub 2}O et nous avons mis en evidence la saturation de ces deux substances pour des champs respectifs de 250 kOE et 320 kOE. (auteur)

  1. Simulation of pulsed ELF magnetic fields generated by GSM mobile phone handsets for human electromagnetic bioeffects research.

    Science.gov (United States)

    Perentos, N; Iskra, S; McKenzie, R J; Cosi, I

    2008-09-01

    Human provocation studies that investigate the effects of Global System for Mobiles (GSM) communication systems on the brain have focused on Radio Frequency (RF) exposure. We wish to further extend such study by investigating the effect of both RF and Extremely Low Frequency (ELF) field exposure, the latter generated by the GSM handset's battery switching. The use of a commercial handset as an exposure source for such investigations is problematic for a number of reasons and therefore a simulated exposure source, capable of producing both RF and ELF components of exposure, is desirable. As a first step in developing such a source, we have quantified and characterized the ELF field from several commercial handsets (the RF characteristics being already well understood). Through experimental measurement we deduce that these fields can be sufficiently simulated by a 9 mm radius loop residing 10 mm beneath the front surface of the handset device and carrying enough current to generate peak fields of 25 microT at the surface of the handset.

  2. Effect of a pulsed magnetic field on permeability of the cornea and sorption properties of the tissue structures and refractive media of the eye

    Energy Technology Data Exchange (ETDEWEB)

    Skrinnik, A.V.

    1986-03-01

    The author attempts to obtain direct proof of increased permeability of the cornea and enhanced sorption properties of the tissue structures and refractive media of the eye under the influence of a pulsed magnetic field (MF). In the course of the investigation, the method of radioactive indication of two substances (/sup 35/S-streptomycin and /sup 75/Se-methionine), widely used in opthalmologic practice, was used. The radioactivity of the working solution of the preparations was 300,000 cpm in 0.1 ml. Changes in the permeability of the cornea were assessed on the basis of changes in radioactivity of the aqueous humor. The concentration of /sup 35/S-streptomycin in aqueous humor of the animals immediately after exposure to MF was significantly higher than in the control. Analysis of permeability of the cornea for /sup 75/Se-methionine also showed increased penetration of radioactivity into the aqueous. The results are evidence of the greater penetrating power of /sup 75/Se-methionine.

  3. Effects of magnetic nanoparticle-incorporated human bone marrow-derived mesenchymal stem cells exposed to pulsed electromagnetic fields on injured rat spinal cord.

    Science.gov (United States)

    Cho, Hyunjin; Choi, Yun-Kyong; Lee, Dong Heon; Park, Hee Jung; Seo, Young-Kwon; Jung, Hyun; Kim, Soo-Chan; Kim, Sung-Min; Park, Jung-Keug

    2013-01-01

    Transplanting mesenchymal stem cells into injured lesions is currently under study as a therapeutic approach for spinal cord injury. In this study, the effects of a pulsed electromagnetic field (PEMF) on injured rat spinal cord were investigated in magnetic nanoparticle (MNP)-incorporated human bone marrow-derived mesenchymal stem cells (hBM-MSCs). A histological analysis revealed significant differences in MNP-incorporated cell distribution near the injured site under the PEMF in comparison with that in the control group. We confirmed that MNP-incorporated cells were widely distributed in the lesions under PEMF. The results suggest that MNP-incorporated hBM-MSCs were guided by the PEMF near the injured site, and that PEMF exposure for 8 H per day over 4 weeks promoted behavioral recovery in spinal cord injured rats. The results show that rats with MNP-incorporated hBM-MSCs under a PEMF were more effective on the Basso, Beattie, and Bresnahan behavioral test and suggest that the PEMF enhanced the action of transplanted cells for recovery of the injured lesion.

  4. Molecules in Magnetic Fields

    Science.gov (United States)

    Berdyugina, Svetlana

    2015-08-01

    Molecules probe cool matter in the Universe and various astrophysical objects. Their ability to sense magnetic fields provides new insights into magnetic properties of these objects. During the past fifteen years we have carried out a theoretical study of molecular magnetic effects such as the Zeeman, Paschen-Back and Hanle effects and their applications for inferring magnetic structures and spatial inhomogeneities on the Sun, cool stars, brown dwarfs, and exoplanets from molecular spectro-polarimetry (e.g., Berdyugina 2011). Here, we present an overview of this study and compare our theoretical predictions with recent laboratory measurements of magnetic properties of some molecules. We present also a new web-based tool to compute molecular magnetic effects and polarized spectra which is supported by the ERC Advanced Grant HotMol.

  5. Pulsed beams as field probes for precision measurement

    OpenAIRE

    Hudson, J. J.; Ashworth, H. T.; Kara, D. M.; Tarbutt, M. R.; Sauer, B.E.; Hinds, E. A.

    2007-01-01

    We describe a technique for mapping the spatial variation of static electric, static magnetic, and rf magnetic fields using a pulsed atomic or molecular beam. The method is demonstrated using a beam designed to measure the electric dipole moment of the electron. We present maps of the interaction region, showing sensitivity to (i) electric field variation of 1.5 V/cm at 3.3 kV/cm with a spatial resolution of 15 mm; (ii) magnetic field variation of 5 nT with 25 mm resolution; (iii) radio-frequ...

  6. Hyperplasticity effect under magnetic pulse straightening of dual phase steel

    Science.gov (United States)

    Falaleev, AP; Meshkov, VV; Shymchenko, A.

    2016-10-01

    An investigation of the behaviour of dual phase steel parts during straightening operations, by means of magnetic pulse treatment, is presented. The mechanical analysis of magnetic-pulse treatment for the straightening of thin-walled sheet metal parts produced from dual phase steel was performed, taking into account the effect of hyperplasticity under the influence of the magnetic field. Taking account of the causes of the hyperplasticity and thus the increase of material plasticity, it has been shown that the magnetic impulse gravity can be adjusted by controlling the operation modes. The dependence of the generated magnetic impulse gravity force on the electrical current strength inducted in this part was explored and used for analysis of the magnetic pulse straightening of dual phase steel part. Experimental results were obtained for thin-walled sheet metal part produced from dual phase steel DP 780. The results are used to demonstrate the material deformation under the influence of magnetic impulse gravity force considering the increase of material plasticity. The dependence of relative material deformation on the generated magnetic impulse gravity as well as on the current strength induced in this material was obtained and analyzed

  7. 脉冲磁场对电厂循环冷却水中异养菌的灭活%Inactivation of heterotrophic bacteria in circulation cooling water system of power plant by pulsed magnetic field

    Institute of Scientific and Technical Information of China (English)

    武红梅; 刘智安; 薛金英; 刘洋; 周斐博; 王玮

    2012-01-01

    为了控制微生物繁殖对电厂循环冷却水系统造成的危害,研究了脉冲电源发生器与线圈绕组相连产生的脉冲磁场对循环水中异养菌的灭活影响,并对灭活关键因素进行了分析。实验结果表明,脉冲磁场对电厂循环冷却水中的异养菌有灭活作用;灭活率对频率和输出电压有选择性,并且随着作用时间和温度的升高而升高;在扫频范围100~1000 Hz、输出电压3 V、单次作用时间为15 s,温度45℃时,异养菌灭活率达到78.8%。%In order to control the harm caused by microbial growth in circulation cooling water systems,the inactivation of heterotrophic bacteria was investigated with the pulsed magnetic fields generated by DC-pulse generator combining with coil windings.Analyses for key factors of sterilization were carried out.The experimental results revealed that the pulsed magnetic fields have effects on inactivation of heterotrophic bacteria in the circulation cooling water system.The inactivation rates take selectivity for the frequency and output voltage.The inactivation rates increase with the increasing of temperature and time duration for each pulse.When the sweep frequency of pulsed magnetic field ranges from 10 to 1 000 Hz,the output voltage is 3 V,and the time duration for each pulse is 15 s,the inactivation rate is 78.8%.

  8. High field rf superconductivity: to pulse or not to pulse

    Energy Technology Data Exchange (ETDEWEB)

    Campisi, I.E.

    1984-10-01

    Experimental data on the behavior of superconductors under the application of rf fields of amplitude comparable to their critical fields are sporadic and not always consistent. In many cases the field level at which breakdown in superconducting rf cavities should be expected has not been clearly established. Tests conducted with very short (approx. 1 ..mu..s) rf pulses indicate that in this mode of operation fields close to the critical values can be consistently reached in superconducting cavities without breakdown. The advantages and disadvantages of the pulsed method are discussed compared to those of the more standard continuous wave (cw) systems. 60 references.

  9. A Novel Transcranial Magnetic Stimulator Inducing Near Rectangular Pulses with Controllable Pulse Width (cTMS)

    Science.gov (United States)

    Jalinous, Reza; Lisanby, Sarah H.

    2013-01-01

    A novel transcranial magnetic stimulation (TMS) device with controllable pulse width (PW) and near rectangular pulse shape (cTMS) is described. The cTMS device uses an insulated gate bipolar transistor (IGBT) with appropriate snubbers to switch coil currents up to 7 kA, enabling PW control from 5 μs to over 100 μs. The near-rectangular induced electric field pulses use 22–34% less energy and generate 67–72% less coil heating compared to matched conventional cosine pulses. CTMS is used to stimulate rhesus monkey motor cortex in vivo with PWs of 20 to 100 μs, demonstrating the expected decrease of threshold pulse amplitude with increasing PW. The technological solutions used in the cTMS prototype can expand functionality, and reduce power consumption and coil heating in TMS, enhancing its research and therapeutic applications. PMID:18232369

  10. ISR Radial Field Magnet

    CERN Multimedia

    1983-01-01

    There were 37 (normal) + 3 (special) Radial Field magnets in the ISR to adjust vertically the closed orbit. Gap heights and strengths were 200 mm and .12 Tm in the normal magnets, 220 mm and .18 Tm in the special ones. The core length was 430 mm in both types. Due to their small length as compared to the gap heights the end fringe field errors were very important and had to be compensated by suitably shaping the poles. In order to save on cables, as these magnets were located very far from their power supplies, the coils of the normal type magnets were formed by many turns of solid cpper conductor with some interleaved layers of hollow conductor directly cooled by circulating water

  11. Pulsed electric field inactivation in a microreactor

    NARCIS (Netherlands)

    Fox, M.B.

    2006-01-01

    Pulsed electric fields (PEF) is a novel, non-thermal pasteurization method which uses short, high electric field pulses to inactivate microorganisms. The advantage of a pasteurization method like PEF compared to regular heat pasteurization is that the taste, flavour, texture and nutritional value ar

  12. Effect of low-frequency pulsed magnetic field on heterotrophic bacteria in circulation cooling water at power plants%低频脉冲磁场对电厂循环冷却水异养菌的影响

    Institute of Scientific and Technical Information of China (English)

    薛金英; 刘智安; 武红梅; 乔波波; 周斐博

    2012-01-01

    The bactericidal experiments of low-frequency pulsed magnetic field have been carried out, aiming at two aspects: the change of variable frequency pulse magnetic field direction, and the two directions of fixed frequency and sweep frequency range. The experimental results show that the change of microbiological physiological function took place under the magnetic field effect. The variable-frequency pulsed magnetic field not only can inhibit the growth of heterotrophic bacteria in circulating cooling water, but also can stimulate the reproduction of heterotrophic bacteria. When the direction of magnetic field is parallel and perpendicular with the water flow direction, the bactericidal rate reaches more than 70%. When the direction of magnetic field is parallel with the water flow direction in the range of 11-17 kHz sweep frequency, the bactericidal rate can reach 82.64%. Therefore, the effective sweep frequency range should be determined,when low frequency pulsed magnetic field is made use of. Thus,better bactericidal effect can be obtained.%从变频脉冲磁场方向的变化以及固定频率与扫频范围两个方向进行了低频脉冲磁场的杀菌实验.实验表明微生物生理功能在磁场作用下发生改变,变频脉冲电磁场既能抑制循环水中异养菌的生长,也能刺激异养菌的繁衍;当磁场方向与水流方向平行和垂直时能达到70%以上的杀菌率,其中磁场方向与水流方向平行时在11~17 kHz频率范围内的杀菌率达到82.64%.因此利用低频脉冲磁场进行杀菌时应确定有效的扫频范围,才能达到较好的杀菌效果.

  13. Angular Spectrum Simulation of Pulsed Ultrasound Fields

    DEFF Research Database (Denmark)

    Du, Yigang; Jensen, Henrik; Jensen, Jørgen Arendt

    2009-01-01

    The optimization of non-linear ultrasound imaging should in a first step be based on simulation, as this makes parameter studies considerably easier than making transducer prototypes. Such a simulation program should be capable of simulating non-linear pulsed fields for arbitrary transducer...... geometries for any kind of focusing and apodization. The Angular Spectrum Approach (ASA) is capable of simulating monochromatic non-linear acoustic wave propagation. However, for ultrasound imaging the time response of each specific point in space is required, and a pulsed ASA simulation with multi temporal....... The RMS error of the pulses for all points in the simulated plane is 10.9%. The good agreement between ASA and Field II simulation for the pulsed ultrasound fields obtained in this paper makes it possible to expand Field II to non-linear pulsed fields....

  14. Cosmic magnetic fields

    CERN Document Server

    Kronberg, Philipp P

    2016-01-01

    Magnetic fields are important in the Universe and their effects contain the key to many astrophysical phenomena that are otherwise impossible to understand. This book presents an up-to-date overview of this fast-growing topic and its interconnections to plasma processes, astroparticle physics, high energy astrophysics, and cosmic evolution. The phenomenology and impact of magnetic fields are described in diverse astrophysical contexts within the Universe, from galaxies to the filaments and voids of the intergalactic medium, and out to the largest redshifts. The presentation of mathematical formulae is accessible and is designed to add insight into the broad range of topics discussed. Written for graduate students and researchers in astrophysics and related disciplines, this volume will inspire readers to devise new ways of thinking about magnetic fields in space on galaxy scales and beyond.

  15. Critical Magnetic Field Determination of Superconducting Materials

    Energy Technology Data Exchange (ETDEWEB)

    Canabal, A.; Tajima, T.; /Los Alamos; Dolgashev, V.A.; Tantawi, S.G.; /SLAC; Yamamoto, T.; /Tsukuba, Natl. Res. Lab. Metrol.

    2011-11-04

    Superconducting RF technology is becoming more and more important. With some recent cavity test results showing close to or even higher than the critical magnetic field of 170-180 mT that had been considered a limit, it is very important to develop a way to correctly measure the critical magnetic field (H{sup RF}{sub c}) of superconductors in the RF regime. Using a 11.4 GHz, 50-MW, <1 {mu}s, pulsed power source and a TE013-like mode copper cavity, we have been measuring critical magnetic fields of superconductors for accelerator cavity applications. This device can eliminate both thermal and field emission effects due to a short pulse and no electric field at the sample surface. A model of the system is presented in this paper along with a discussion of preliminary experimental data.

  16. Superconductivity in Strong Magnetic Field (Greater Than Upper Critical Field)

    Energy Technology Data Exchange (ETDEWEB)

    Tessema, G.X.; Gamble, B.K.; Skove, M.J.; Lacerda, A.H.; Mielke, C.H.

    1998-08-22

    The National High Magnetic Field Laboratory, funded by the National Science Foundation and other US federal Agencies, has in recent years built a wide range of magnetic fields, DC 25 to 35 Tesla, short pulse 50 - 60 Tesla, and quasi-continuous 60 Tesla. Future plans are to push the frontiers to 45 Tesla DC and 70 to 100 Tesla pulse. This user facility, is open for national and international users, and creates an excellent tool for materials research (metals, semiconductors, superconductors, biological systems ..., etc). Here we present results of a systematic study of the upper critical field of a novel superconducting material which is considered a promising candidate for the search for superconductivity beyond H{sub c2} as proposed by several new theories. These theories predict that superconductors with low carrier density can reenter the superconducting phase beyond the conventional upper critical field H{sub c2}. This negates the conventional thinking that superconductivity and magnetic fields are antagonistic.

  17. Solar Magnetic Fields

    Indian Academy of Sciences (India)

    J. O. Stenflo

    2008-03-01

    Since the structuring and variability of the Sun and other stars are governed by magnetic fields, much of present-day stellar physics centers around the measurement and understanding of the magnetic fields and their interactions. The Sun, being a prototypical star, plays a unique role in astrophysics, since its proximity allows the fundamental processes to be explored in detail. The PRL anniversary gives us an opportunity to look back at past milestones and try to identify the main unsolved issues that will be addressed in the future.

  18. A pulsed magnetic stress applied to Drosophila melanogaster flies

    Science.gov (United States)

    Delle Side, D.; Bozzetti, M. P.; Friscini, A.; Giuffreda, E.; Nassisi, V.; Specchia, V.; Velardi, L.

    2014-04-01

    We report the development of a system to feed pulsed magnetic stress to biological samples. The device is based on a RLC circuit that transforms the energy stored in a high voltage capacitor into a magnetic field inside a coil. The field has been characterized and we found that charging the capacitor with 24 kV results in a peak field of 0.4 T. In order to test its effect, we applied such a stress to the Drosophila melanogaster model and we examined its bio-effects. We analysed, in the germ cells, the effects on the control of specific DNA repetitive sequences that are activated after different environmental stresses. The deregulation of these sequences causes genomic instability and chromosomes breaks leading to sterility. The magnetic field treatment did not produce effects on repetitive sequences in the germ cells of Drosophila. Hence, this field doesn't produce deleterious effects linked to repetitive sequences derepression.

  19. Solar Magnetic Fields

    CERN Document Server

    Hood, Alan W

    2011-01-01

    This review provides an introduction to the generation and evolution of the Sun's magnetic field, summarising both observational evidence and theoretical models. The eleven year solar cycle, which is well known from a variety of observed quantities, strongly supports the idea of a large-scale solar dynamo. Current theoretical ideas on the location and mechanism of this dynamo are presented. The solar cycle influences the behaviour of the global coronal magnetic field and it is the eruptions of this field that can impact on the Earth's environment. These global coronal variations can be modelled to a surprising degree of accuracy. Recent high resolution observations of the Sun's magnetic field in quiet regions, away from sunspots, show that there is a continual evolution of a small-scale magnetic field, presumably produced by small-scale dynamo action in the solar interior. Sunspots, a natural consequence of the large-scale dynamo, emerge, evolve and disperse over a period of several days. Numerical simulation...

  20. High field superconducting magnets

    Science.gov (United States)

    Hait, Thomas P. (Inventor); Shirron, Peter J. (Inventor)

    2011-01-01

    A superconducting magnet includes an insulating layer disposed about the surface of a mandrel; a superconducting wire wound in adjacent turns about the mandrel to form the superconducting magnet, wherein the superconducting wire is in thermal communication with the mandrel, and the superconducting magnet has a field-to-current ratio equal to or greater than 1.1 Tesla per Ampere; a thermally conductive potting material configured to fill interstices between the adjacent turns, wherein the thermally conductive potting material and the superconducting wire provide a path for dissipation of heat; and a voltage limiting device disposed across each end of the superconducting wire, wherein the voltage limiting device is configured to prevent a voltage excursion across the superconducting wire during quench of the superconducting magnet.

  1. Differential effects of magnetic pulses on the orientation of naturally migrating birds.

    Science.gov (United States)

    Holland, Richard A

    2010-11-01

    In migratory passerine birds, strong magnetic pulses are thought to be diagnostic of the remagnetization of iron minerals in a putative sensory system contained in the beak. Previous evidence suggests that while such a magnetic pulse affects the orientation of migratory birds in orientation cages, no effect was present when pulse-treated birds were tested in natural migration. Here we show that two migrating passerine birds treated with a strong magnetic pulse, designed to alter the magnetic sense, migrated in a direction that differed significantly from that of controls when tested in natural conditions. The orientation of treated birds was different depending on the alignment of the pulse with respect to the magnetic field. These results can aid in advancing understanding of how the putative iron-mineral-based receptors found in birds' beaks may be used to detect and signal the intensity and/or direction of the Earth's magnetic field.

  2. Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

    Directory of Open Access Journals (Sweden)

    Shinsuke Nakayama

    Full Text Available This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG. The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

  3. Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

    Science.gov (United States)

    Nakayama, Shinsuke; Sawamura, Kenta; Mohri, Kaneo; Uchiyama, Tsuyoshi

    2011-01-01

    This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI) sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT) level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG). The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

  4. Influence of Magnetic Field Amplitude on Quantity and Sizes of Disintegration Fragments of Magnetic Particles Cluster

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The disintegration of a mass of magnetic particles is investigated at pulsing switching on a magnetic field. The influence of field value on quantity, sizes and allocation of fragments of disintegration is explored. The presence of two critical fields, defining the process of disintegration, is revealed. The results can be used at manufacture of packings to magnetic filters.

  5. Pulsed light and pulsed electric field for foods and eggs.

    Science.gov (United States)

    Dunn, J

    1996-09-01

    Two new technologies for use in the food industry are described. The first method discussed uses intense pulse of light. This pulsed light (PureBright) process uses short duration flashes of broad spectrum "white" light to kill all exposed microorganisms, including vegetative bacteria, microbial and fungal spores, viruses, and protozoan oocysts. Each pulse, or flash, of light lasts only a few hundred millionths of a second (i.e., a few hundred microseconds). The intensity of each flash of light is about 20,000 times the intensity of sunlight at the earth's surface. The flashes are typically applied at a rate of about one to tens of flashes per second. For most applications, a few flashes applied in a fraction of a second provide an effective treatment. High microbial kill can be achieved, for example, on the surfaces of packaging materials, on packaging and processing equipment, foods, and medical devices as well as on many other surfaces. In addition, some bulk materials such as water and air that allow penetration of the light can be sterilized. The results of tests to measure the effects of pulsed light on Salmonella enteritiditis on eggs are presented. The second method discussed uses multiple, short duration, high intensity electric field pulses to kill vegetative microorganisms in pumpable products. This pulsed electric field (or CoolPure) process can be applied at modest temperatures at which no appreciable thermal damage occurs and the original taste, color, texture, and functionality of products can be retained.

  6. High Magnetic field generation for laser-plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, B B; Froula, D H; Davis, P F; Ross, J S; Fulkerson, S; Bower, J; Satariano, J; Price, D; Glenzer, S H

    2006-05-01

    An electromagnetic solenoid was developed to study the effect of magnetic fields on electron thermal transport in laser plasmas. The solenoid, which is driven by a pulsed power system suppling 30 kJ, achieves magnetic fields of 13 T. The field strength was measured on the solenoid axis with a magnetic probe and optical Zeeman splitting. The measurements agree well with analytical estimates. A method for optimizing the solenoid design to achieve magnetic fields exceeding 20 T is presented.

  7. Pulsed field gel electrophoresis a practical guide

    CERN Document Server

    Birren, Bruce

    1993-01-01

    Pulsed Field Gel Electrophoresis: A Practical Guide is the first laboratory manual to describe the theory and practice of this technique. Based on the authors' experience developing pulsed field gel instruments and teaching procedures, this book provides everything a researcher or student needs to know in order to understand and carry out pulsed field gel experiments. Clear, well-tested protocols assume only that users have a basic familiarity with molecular biology. Thorough coverage of useful data, theory, and applications ensures that this book is also a lasting resource for more adv

  8. International magnetic pulse compression workshop: (Proceedings)

    Energy Technology Data Exchange (ETDEWEB)

    Kirbie, H.C.; Newton, M.A.; Siemens, P.D.

    1991-04-01

    A few individuals have tried to broaden the understanding of specific and salient pulsed-power topics. One such attempt is this documentation of a workshop on magnetic switching as it applies primarily to pulse compression (power transformation), affording a truly international perspective by its participants under the initiative and leadership of Hugh Kirbie and Mark Newton of the Lawrence Livermore National Laboratory (LLNL) and supported by other interested organizations. During the course of the Workshop at Granlibakken, a great deal of information was amassed and a keen insight into both the problems and opportunities as to the use of this switching approach was developed. The segmented workshop format proved ideal for identifying key aspects affecting optimum performance in a variety of applications. Individual groups of experts addressed network and system modeling, magnetic materials, power conditioning, core cooling and dielectrics, and finally circuits and application. At the end, they came together to consolidate their input and formulate the workshop's conclusions, identifying roadblocks or suggesting research projects, particularly as they apply to magnetic switching's trump card--its high-average-power-handling capability (at least on a burst-mode basis). The workshop was especially productive both in the quality and quantity of information transfer in an environment conducive to a free and open exchange of ideas. We will not delve into the organization proper of this meeting, rather we wish to commend to the interested reader this volume, which provides the definitive and most up-to-date compilation on the subject of magnetic pulse compression from underlying principles to current state of the art as well as the prognosis for the future of magnetic pulse compression as a consensus of the workshop's organizers and participants.

  9. Magnetic Field Measurement on a Refined Kicker

    CERN Document Server

    Fan, Tai-Ching; Lin, Fu-Yuan

    2005-01-01

    To prepare for the operation of top-up mode and increase the efficiency of injection at storage ring, National Synchrotron Radiation Research Center (NSRRC) has upgraded the kicker magnets and power supply. We have built up a new magnetic field measurement system to test the kicker. This system, including a search coil and a coil loop, can map the field and take the first integral of field automatically. We also simulate the trajectory of electron beam by pulsed wire method of field measurement. We analyze the performance of the kicker system in this paper.

  10. Magnetic fields in diffuse media

    CERN Document Server

    Pino, Elisabete; Melioli, Claudio

    2015-01-01

    This volume presents the current knowledge of magnetic fields in diffuse astrophysical media. Starting with an overview of 21st century instrumentation to observe astrophysical magnetic fields, the chapters cover observational techniques, origin of magnetic fields, magnetic turbulence, basic processes in magnetized fluids, the role of magnetic fields for cosmic rays, in the interstellar medium and for star formation. Written by a group of leading experts the book represents an excellent overview of the field. Nonspecialists will find sufficient background to enter the field and be able to appreciate the state of the art.

  11. New Pulsed Orbit Bump Magnets for the Fermilab Booster Synchrotron

    CERN Document Server

    Lackey, James; John, Carson; Kashikhin, Vladimir; Makarov, Alexander; Prebys, Eric

    2005-01-01

    The beam from the Fermilab Linac is injected onto a bump in the closed orbit of the Booster Synchrotron where a carbon foil strips the electrons from the Linac’s negative ion hydrogen beam. Although the Booster itself runs at 15Hz, heat dissipation in the orbit bump magnets has been one limitation to the fraction of the cycles that can be used for beam. New, 0.28T pulsed window frame dipole magnets have been constructed that will fit into the same space as the old ones, run at the full repetition rate of the Booster, and provide a larger bump to allow a cleaner injection orbit. The new magnets use a high saturation flux density Ni-Zn ferrite in the yoke rather than laminated steel. The presented magnetic design includes two and three dimensional magnetic field calculations with eddy currents and ferrite nonlinear effects.

  12. Compensation of Gradient-Induced Magnetic Field Perturbations

    Science.gov (United States)

    Nixon, Terence W.; McIntyre, Scott; Rothman, Douglas L.; de Graaf, Robin A.

    2008-01-01

    Pulsed magnetic field gradients are essential for MR imaging and localized spectroscopy applications. However, besides the desired linear field gradients, pulsed currents in a strong external magnetic field also generate unwanted effects like eddy currents, gradient coil vibrations and acoustic noise. While the temporal magnetic field perturbations associated with eddy currents lead to spectral line shape distortions and signal loss, the vibration-related modulations lead to anti-symmetrical sidebands of any large signal (i.e. water), thereby obliterating the signals from smaller signals (i.e. metabolites). Here the measurement, characterization and compensation of vibrations-related magnetic field perturbations is presented. Following a quantitative evaluation of the various temporal components of the main magnetic field, a digital B0 magnetic field waveform is generated which reduces all temporal variations of the main magnetic field to within the spectral noise level. PMID:18329304

  13. Shaped magnetic field pulses by multi-coil repetitive transcranial magnetic stimulation (rTMS) differentially modulate anterior cingulate cortex responses and pain in volunteers and fibromyalgia patients

    Science.gov (United States)

    2013-01-01

    Background Repetitive transcranial magnetic stimulation (rTMS) has shown promise in the alleviation of acute and chronic pain by altering the activity of cortical areas involved in pain sensation. However, current single-coil rTMS technology only allows for effects in surface cortical structures. The ability to affect activity in certain deep brain structures may however, allow for a better efficacy, safety, and tolerability. This study used PET imaging to determine whether a novel multi-coil rTMS would allow for preferential targeting of the dorsal anterior cingulate cortex (dACC), an area always activated with pain, and to provide preliminary evidence as to whether this targeted approach would allow for efficacious, safe, and tolerable analgesia both in a volunteer/acute pain model as well as in fibromyalgia chronic pain patients. Methods Part 1: Different coil configurations were tested in a placebo-controlled crossover design in volunteers (N = 16). Tonic pain was induced using a capsaicin/thermal pain model and functional brain imaging was performed by means of H215O positron emission tomography – computed tomography (PET/CT) scans. Differences in NRS pain ratings between TMS and sham treatment (NRSTMS-NRSplacebo) which were recorded each minute during the 10 minute PET scans. Part 2: 16 fibromyalgia patients were subjected to 20 multi-coil rTMS treatments over 4 weeks and effects on standard pain scales (Brief Pain Inventory, item 5, i.e. average pain NRS over the last 24 hours) were recorded. Results A single 30 minute session using one of 3 tested rTMS coil configurations operated at 1 Hz consistently produced robust reduction (mean 70% on NRS scale) in evoked pain in volunteers. In fibromyalgia patients, the 20 rTMS sessions also produced a significant pain inhibition (43% reduction in NRS pain over last 24 hours), but only when operated at 10 Hz. This degree of pain control was maintained for at least 4 weeks after the final session

  14. Coronal Magnetic Field Models

    Science.gov (United States)

    Wiegelmann, Thomas; Petrie, Gordon J. D.; Riley, Pete

    2017-09-01

    Coronal magnetic field models use photospheric field measurements as boundary condition to model the solar corona. We review in this paper the most common model assumptions, starting from MHD-models, magnetohydrostatics, force-free and finally potential field models. Each model in this list is somewhat less complex than the previous one and makes more restrictive assumptions by neglecting physical effects. The magnetohydrostatic approach neglects time-dependent phenomena and plasma flows, the force-free approach neglects additionally the gradient of the plasma pressure and the gravity force. This leads to the assumption of a vanishing Lorentz force and electric currents are parallel (or anti-parallel) to the magnetic field lines. Finally, the potential field approach neglects also these currents. We outline the main assumptions, benefits and limitations of these models both from a theoretical (how realistic are the models?) and a practical viewpoint (which computer resources to we need?). Finally we address the important problem of noisy and inconsistent photospheric boundary conditions and the possibility of using chromospheric and coronal observations to improve the models.

  15. Experimental Study on Application of Pulsed Magnetic Field in Reverse Flotation of a Magnetite%脉冲磁场在某磁铁矿反浮选中应用的试验研究

    Institute of Scientific and Technical Information of China (English)

    牛国朋; 曹亦俊; 杨兴满; 刘永华; 李超

    2012-01-01

    介绍了旋流-静态微泡浮选柱加脉冲磁场后的设备结构与工作原理,对比进行了磁铁矿的浮选柱工艺反浮选试验及加脉冲磁场后的浮选柱工艺反浮选试验。研究表明,相比浮选柱工艺,加脉冲磁场后,在浮选精矿、尾矿产品质量及回收率均有提高的情况下,新设备的处理能力提高了45.83%,并简化了工艺流程。%The structure and working principle of cyclonic-static micro-bubble flotation column with an additional pulsed magnetic field were introduced.The tests of magnetite reverse flotation process by using cyclonic-static micro-bubble flotation column without and with an additional pulsed magnetic were done and compared respectively.Studies showed that after adding pulsed magnetic,the processing capacity of the device was raised by 45.83%,and the quality of concentrate and tailings and iron recovery were improved also,besides,the technological flow-sheet was simplified obviously.

  16. Magnetic field switchable dry adhesives.

    Science.gov (United States)

    Krahn, Jeffrey; Bovero, Enrico; Menon, Carlo

    2015-02-01

    A magnetic field controllable dry adhesive device is manufactured. The normal adhesion force can be increased or decreased depending on the presence of an applied magnetic field. If the magnetic field is present during the entire normal adhesion test cycle which includes both applying a preloading force and measuring the pulloff pressure, a decrease in adhesion is observed when compared to when there is no applied magnetic field. Similarly, if the magnetic field is present only during the preload portion of the normal adhesion test cycle, a decrease in adhesion is observed because of an increased stiffness of the magnetically controlled dry adhesive device. When the applied magnetic field is present during only the pulloff portion of the normal adhesion test cycle, either an increase or a decrease in normal adhesion is observed depending on the direction of the applied magnetic field.

  17. Field mapping of ballistic pressure pulse sources

    Directory of Open Access Journals (Sweden)

    Rad Abtin Jamshidi

    2015-09-01

    Full Text Available Ballistic pressure pulse sources are used since late 1990s for the extracorporeal treatment of chronic Enthesitis. Newly indications are found in trigger-point-therapy for the treatment of musculoskeletal disorders. In both applications excellent results without relevant side effects were found in clinical trials. The technical principle of pressure pulse source is based on the same techniques used in air guns. A projectile is accelerated by pressurized air and hits the applicator with high kinetic energy. By this a compression wave travels through the material and induces a fast (4..5μs, almost singular pressure pulse of 2..10 MPa, which is followed by an equally short rarefaction phase of about the same amplitude. It is assumed that the pressure pulse accounts for the biomedical effects of the device. The slower inertial motion of the waveguide is damped by elastic stoppers, but still can be measured several micro seconds after the initial pressure pulse. In order to characterize the pressure pulse devices, field mapping is performed on several radial pressure pulse sources using the fiber optic hydrophone and a polyvinylidenfluorid (PVDF piezoelectric hydrophone. It could be shown that the current standard (IEC 61846 is not appropriate for characterization of ballistic pressure pulse sources.

  18. Limits for primordial magnetic fields

    CERN Document Server

    Caprini, Chiara

    2011-01-01

    A possible explanation for the origin of the magnetic fields observed today in matter structures is that they were generated in the primordial universe. After briefly revising the model of a primordial stochastic magnetic field and sketching the main features of its time evolution in the primordial plasma, we illustrate the current upper bounds on the magnetic field amplitude and spectral index from Cosmic Microwave Background observations and gravitational wave production. We conclude that a primordial magnetic field generated by a non-causal process such as inflation with a red spectrum seems to be favoured as a seed for the magnetic fields observed today in structures.

  19. Behavior of metals Induced by magnetic pulse loading

    Directory of Open Access Journals (Sweden)

    Svetlana Atroshenko

    2015-01-01

    Full Text Available The investigation of copper and aluminum ring samples was carried out using magnetic pulse loading. Two modifications of the magnetic pulse technique were used. They were based on a GKVI-300 high-voltage narrow-pulse generator Morozov et al. (2011 [1]. It is possible using these two approaches to decrease the period of the harmonic load up to 100 ns. The study of fracture surfaces of aluminum and copper samples after the test was carried out on an optical microscope Axio-Observer-Z1-M in a dark field, and study of the cross sections structure – in the bright field or C-DIC. The structure has been studied in cross sections after appropriate etching. Grain size and the number of pores on the surface of cross sections were determined after etching. Microhardness was measured on a PMT-3 device with a load of 20 g. The optical micrographs of aluminum demonstrate that the long pulse causes almost fully ductile fracture. In the case of the short pulse, the number of fibers decreases: the fracture surface exhibits the signs of both ductile cup fracture and brittle crystalline fracture with cracks, which are sometimes rather deep. In addition, the short pulse results in twinning, which seems surprising for aluminum featuring a high stacking fault energy. It is seen that under short loading dynamic recrystallization occurs. As for copper samples before loading they were in the form of single crystal and after loading their structure due to dynamic recrystallization consists of small grain. The specimen with notch has more developed dynamic recrystallization shear bands.

  20. Investigation of magnetoabsorption at different temperatures in HgTe/CdHgTe quantum-well heterostructures in pulsed magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Platonov, V. V.; Kudasov, Yu. B.; Makarov, I. V.; Maslov, D. A.; Surdin, O. M. [Sarov Physical–Technical Institute—National Research Nuclear University MEPhI (Russian Federation); Zholudev, M. S.; Ikonnikov, A. V.; Gavrilenko, V. I. [Russian Academy of Sciences, Institute of Physics of Microstructures (Russian Federation); Mikhailov, N. N.; Dvoretsky, S. A. [Russian Academy of Sciences, Rzhanov Institute of Semiconductor Physics, Siberian Branch (Russian Federation)

    2015-12-15

    The magnetoabsorption in magnetic fields as high as 40 T is investigated at T > 77 K in HgTe/CdHgTe quantum-well heterostructures (d{sub QW} ≈ 8 nm). The spectra reveal two lines associated both with intraband transition from the lower Landau level in the conduction band and with interband transition. It is shown that the band structure in these systems changes from inverted to normal with increasing temperature.

  1. Effects of beam velocity and density on an ion-beam pulse moving in magnetized plasmas

    CERN Document Server

    Zhao, Xiao-ying; Zhao, Yong-tao; Qi, Xin; Yang, Lei

    2016-01-01

    The wakefield and stopping power of an ion-beam pulse moving in magnetized plasmas are investigated by particle-in-cell (PIC) simulations. The effects of beam velocity and density on the wake and stopping power are discussed. In the presence of magnetic field, it is found that beside the longitudinal conversed V-shaped wakes, the strong whistler wave are observed when low-density and low-velocity pulses moving in plasmas. The corresponding stopping powers are enhanced due to the drag of these whistler waves. As beam velocities increase, the whistler waves disappear, and only are conversed V-shape wakes observed. The corresponding stopping powers are reduced compared with these in isotropic plasmas. When high-density pulses transport in the magnetized plasmas, the whistler waves are greatly inhibited for low-velocity pulses and disappear for high-velocity pulses. Additionally, the magnetic field reduces the stopping powers for all high-density cases.

  2. Superhorizon magnetic fields

    CERN Document Server

    Campanelli, Leonardo

    2015-01-01

    [Abridged] We analyze the evolution of superhorizon-scale magnetic fields from the end of inflation till today. Whatever is the mechanism responsible for their generation during inflation, we find that a given magnetic mode with wavenumber $k$ evolves, after inflation, according to the values of $k\\eta_e$, $n_{\\mathbf{k}}$, and $\\Omega_k$, where $\\eta_e$ is the conformal time at the end of inflation, $n_{\\mathbf{k}}$ is the number density spectrum of inflation-produced photons, and $\\Omega_k$ is the phase difference between the two Bogolubov coefficients which characterize the state of that mode at the end of inflation. For any realistic inflationary magnetogenesis scenario, we find that $n_{\\mathbf{k}}^{-1} \\ll |k\\eta_e| \\ll 1$, and three evolutionary scenarios are possible: ($i$) $|\\Omega_k \\mp \\pi| = \\mathcal{O}(1)$, in which case the evolution of the magnetic spectrum $B_k(\\eta)$ is adiabatic, $a^2B_k(\\eta) = \\mbox{const}$, with $a$ being the expansion parameter; ($ii$) $|\\Omega_k \\mp \\pi| \\ll |k\\eta_e|$,...

  3. RESEARCH ON CHANGE OF CO2 PRODUCED BY RESPIRATION OF WHEAT STORED UNDER PULSED MAGNETIC FIELD%脉冲磁场下储藏小麦自身呼吸CO2变化分析研究

    Institute of Scientific and Technical Information of China (English)

    蒋华伟; 李战升

    2013-01-01

    储粮自身呼吸是陈化和霉变的重要原因之一,为动态了解储藏期间粮食呼吸的效应,开展了小麦自身所产生CO2浓度变化的研究工作.对常规条件下小麦自身呼吸CO2浓度与脉冲磁场中不同强度和脉冲数所对应的试验数据进行分析研究,结果表明:低水分储藏小麦的CO2浓度呈线性恒稳变化,脉冲磁场能抑制小麦的后期呼吸从而延缓小麦的陈化变质进程;而中、高水分的数据严重偏离线性关系,变化幅度较大,在高强度和大脉冲数的磁场中,出现曲线变化的拐点(阈值),其对小麦呼吸作用中CO2浓度变化发生窗口效应,在小麦存储中具有促进作用.%The respiration of storage food is one of the important reasons causing aging and mildewing.In this paper,we studied the concentration change of CO2 produced by respiration of wheat in order to dynamically study the grain respiration effect during storage.We analyzed the CO2 concentration of wheat under the conventional condition as well as the test data corresponding to different strengths and pulse numbers in a pulsed magnetic field.The results showed that the CO2 concentration of low-moisture stored wheat had a linear constant change; the pulsed magnetic filed could inhibit the respiration effect of wheat at the later stage so as to postpone aging and deterioration of wheat.However,the data of medium and high-moisture stored wheat deviated from the linear relationship severely,and had large change; and an inflection point (threshold) occurred in the curve in a magnetic field with high strength and large pulse number,so that the pulsed magnetic filed had a window effect on the change of CO2 concentration caused by respiration of the wheat so as to facilitate wheat storage.

  4. SCUPOL Magnetic Field Analysis

    CERN Document Server

    Poidevin, Frederick; Kowal, Grzegorz; Pino, Elisabete de Gouveia Dal; Magalhaes, Antonio-Mario

    2013-01-01

    We present an extensive analysis of the 850 microns polarization maps of the SCUPOL Catalog produced by Matthews et al. (2009), focusing exclusively on the molecular clouds and star-forming regions. For the sufficiently sampled regions, we characterize the depolarization properties and the turbulent-to-mean magnetic field ratio of each region. Similar sets of parameters are calculated from 2D synthetic maps of dust emission polarization produced with 3D MHD numerical simulations scaled to the S106, OMC-2/3, W49 and DR21 molecular clouds polarization maps. For these specific regions the turbulent MHD regimes retrieved from the simulations, as described by the turbulent Alfv\\`en and sonic Mach numbers, are consistent within a factor 1 to 2 with the values of the same turbulent regimes estimated from the analysis of Zeeman measurements data provided by Crutcher (1999). Constraints on the values of the inclination angle of the mean magnetic field with respect to the LOS are also given. The values obtained from th...

  5. Schwinger Pair Production in Pulsed Electric Fields

    CERN Document Server

    Kim, Sang Pyo; Ruffini, Remo

    2012-01-01

    We numerically investigate the temporal behavior and the structure of longitudinal momentum spectrum and the field polarity effect on pair production in pulsed electric fields in scalar quantum electrodynamics (QED). Using the evolution operator expressed in terms of the particle and antiparticle operators, we find the exact quantum states under the influence of electric pulses and measure the number of pairs of the Minkowski particle and antiparticle. The number of pairs, depending on the configuration of electric pulses, exhibits rich structures in the longitudinal momentum spectrum and undergoes diverse dynamical behaviors at the onset of the interaction but always either converges to a momentum-dependent constant or oscillates around a momentum-dependent time average after the completion of fields.

  6. Magnetic Fields: Visible and Permanent.

    Science.gov (United States)

    Winkeljohn, Dorothy R.; Earl, Robert D.

    1983-01-01

    Children will be able to see the concept of a magnetic field translated into a visible reality using the simple method outlined. Standard shelf paper, magnets, iron filings, and paint in a spray can are used to prepare a permanent and well-detailed picture of the magnetic field. (Author/JN)

  7. Study on the pulsed-field magnetization of single domain YBCO bulk%单畴 YBCO 超导块材的脉冲充磁磁化规律

    Institute of Scientific and Technical Information of China (English)

    李佳伟; 杨万民

    2015-01-01

    为了提高氧化钇钡铜(YBCO)超导体的捕获磁场,成功制备了单畴 YBCO 超导块材,研究了不同强度脉冲磁场和充磁次数对 YBCO 超导体捕获磁场的影响。结果表明:对直径20 mm 的YBCO 超导体,存在一个最佳的脉冲磁场强度,使得捕获磁场最强;当采用最佳脉冲磁场充磁时,增加充磁次数可以显著增加 YBCO 超导体的捕获磁场。进一步采用 Bean 模型解释了该磁化规律。本文的研究结果有助于提高 YBCO 超导体的磁化效果和理解 YBCO 超导体的磁化机制。%In order to improve the trapped field of YBCO bulk,a single domain YBCO bulk was successfully fabricated,and the effects of the intensity and the magnetization time of pulsed mag-netic fields on the trapped field have been investigated in detail.The result shows that the intensi-ty of the trapped field in YBCO superconductor with the diameter of 20 mm may reach its maxi-mum when the magnetic field with an optimal intensity(4.8 T)is applied.The trapped field in-creases significantly when the sample is magnetized for several times by the optimal magnetic field.Furthermore,the magnetization process is explained by Bean model.The results in this work helps to improve the magnetization efficiency of YBCO superconductors and understand the mag-netization mechanism.

  8. EXTERNAL MAGNETIC-PULSE STRAIGHTENING OF CARS BODY PANELS

    Directory of Open Access Journals (Sweden)

    A. Hnatov

    2014-10-01

    Full Text Available The basics of magnetic-pulse attraction of both ferromagnetic and non-ferromagnetic thin-wall sheet metals are investigated. The design models of inductor systems-magnetic-pulse straightening tools are presented. The final analytical expressins for excited efforts design in the tools under consideration are introduced. The practical testing of magnetic-pulse straightening with the tools under study is given.

  9. Magnetic resonance imaging without field cycling at less than earth's magnetic field

    Science.gov (United States)

    Lee, Seong-Joo; Shim, Jeong Hyun; Kim, Kiwoong; Yu, Kwon Kyu; Hwang, Seong-min

    2015-03-01

    A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π / 2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

  10. Simultaneous electronic and the magnetic excitation of a ferromagnet by intense THz pulses

    CERN Document Server

    Shalaby, Mostafa; Hauri, Christoph P

    2015-01-01

    The speed of magnetization reversal is a key feature in magnetic data storage. Magnetic fields from intense THz pulses have been recently shown to induce small magnetization dynamics in Cobalt thin film on the sub-picosecond time scale. Here, we show that at higher field intensities, the THz electric field starts playing a role, strongly changing the dielectric properties of the cobalt thin film. Both the electronic and magnetic responses are found to occur simultaneously, with the electric field response persistent on a time scale orders of magnitude longer than the THz stimulus

  11. Penetration of conductive plasma flows across a magnetic field

    Science.gov (United States)

    Plechaty, Christopher Ryan

    2008-02-01

    Plasma interacts with magnetic fields in a variety of natural and laboratory settings. While a magnetic field "traps" isolated charged particles, plasma penetration across magnetic field is observed in many situations where a plasma-magnetic interface exists. For example, in the realm of pulsed power technology, this behavior is important for magnetically insulated transmission lines and for plasma opening switches. In the realm of astrophysics, the nature of the interaction between the solar wind plasma and the Earth's magnetic field affects the reliability of telecommunication devices and satellites. Experiments were performed at the Nevada Terawatt Facility to investigate how a conductive plasma penetrates an externally applied magnetic field. In experiment, a plasma flow was produced by laser ablation. This plasma was observed to penetrate an externally applied magnetic field produced by a 0.6 MA pulsed power generator. In experiment, the duration of the laser pulse was changed by three orders of magnitude, from ns (GW pulse power) to ps (TW) . This resulted in a significant variation of the plasma parameters, which in turn led to the actuation of different magnetic field penetration mechanisms.

  12. Saturable inductor and transformer structures for magnetic pulse compression

    Science.gov (United States)

    Birx, Daniel L.; Reginato, Louis L.

    1990-01-01

    Saturable inductor and transformer for magnetic compression of an electronic pulse, using a continuous electrical conductor looped several times around a tightly packed core of saturable inductor material.

  13. Preliminary Studies on Pulsed Electric Field Breakdown of Lead Azide

    Science.gov (United States)

    1976-10-01

    1/2 OS CO ton NO. S3L TECHNICAL REPORT 4991 PRELIMINARY SUJDfES ON PULSED ELECTRIC FIELD BREAKDOWN OF LEAD AZIDE L AVRAMI M. BUMS D. DOWNS...Introduction Background A. Contact Effects B. Pulsed Electric Field Measurements Experimental A. Contact Effects B. Pulsed Electric Fields Discussion...B. Pulsed Electric Field Measurements The application of pulsed electric fields to lead azide does not exactly simulate the conditions experienced

  14. Reconnection of Magnetic Fields

    Science.gov (United States)

    Birn, J.; Priest, E. R.

    2007-01-01

    Preface; Part I. Introduction: 1.1 The Sun E. R. Priest; 1.2 Earth's magnetosphere J. Birn; Part II. Basic Theory of MHD Reconnection: 2.1 Classical theory of two-dimensional reconnection T. G. Forbes; 2.2 Fundamental concepts G. Hornig; 2.3 Three-dimensional reconnection in the absence of magnetic null points G. Hornig; 2.4 Three-dimensional reconnection at magnetic null points D. Pontin; 2.5 Three-dimensional flux tube reconnection M. Linton; Part III. Basic Theory of Collisionless Reconnection: 3.1 Fundamentals of collisionless reconnection J. Drake; 3.2 Diffusion region physics M. Hesse; 3.3 Onset of magnetic reconnection P. Pritchett; 3.4 Hall-MHD reconnection A. Bhattacharjee and J. Dorelli; 3.5 Role of current-aligned instabilities J. Büchner and W. Daughton; 3.6 Nonthermal particle acceleration M. Hoshino; Part IV. Reconnection in the Magnetosphere: 4.1 Reconnection at the magnetopause: concepts and models J. G. Dorelli and A. Bhattacharjee; 4.2 Observations of magnetopause reconnection K.-H. Trattner; 4.3 On the stability of the magnetotail K. Schindler; 4.4 Simulations of reconnection in the magnetotail J. Birn; 4.5 Observations of tail reconnection W. Baumjohann and R. Nakamura; 4.6 Remote sensing of reconnection M. Freeman; Part V. Reconnection in the Sun's Atmosphere: 5.1 Coronal heating E. R. Priest; 5.2 Separator reconnection D. Longcope; 5.3 Pinching of coronal fields V. Titov; 5.4 Numerical experiments on coronal heating K. Galsgaard; 5.5 Solar flares K. Kusano; 5.6 Particle acceleration in flares: theory T. Neukirch; 5.7 Fast particles in flares: observations L. Fletcher; 6. Open problems J. Birn and E. R. Priest; Bibliography; Index.

  15. Magnetic pulse welding on the cutting edge of industrial applications

    Directory of Open Access Journals (Sweden)

    R. M. Miranda

    2014-03-01

    Full Text Available Magnetic Pulse Welding (MPW applies the electromagnetic principles postulated in the XIXth century and later demonstrated. In recent years the process has been developed to meet highly demanding market needs involving dissimilar material joining, specially involving difficult-to-weld materials. It is a very high speed joining process that uses an electromagnetic force to accelerate one material against the other, resulting in a solid state weld with no external heat source and no thermal distortions. A high power source, the capacitor, a discharge switch and a coil constitute the minimum equipment necessary for this process. A high intensity current flowing through a coil near an electrically conductive material, locally produce an intense magnetic field that generates eddy currents in the flyer according to Lenz law. The induced electromotive force gives rise to a current whose magnetic field opposes the original change in magnetic flux. The effect of this secondary current moving in the primary magnetic field is the generation of a Lorentz force, which accelerates the flyer at a very high speed. If a piece of material is placed in the trajectory of the flyer, the impact will produce an atomic bond in a solid state weld. This paper discusses the fundamentals of the process in terms of phenomenology and analytical modeling and numerical simulation. Recent industrial applications are presented in terms of materials, joint configurations and real examples as well as advantages and disadvantages of the process.

  16. Observation of spin diffusion in zero-field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Suter, D.; Jarvie, T.P.; Sun, B.; Pines, A.

    1987-07-06

    We report the measurement of spin diffusion at zero field, observed by two-dimensional deuterium magnetic resonance of a polycrystalline sample. This demonstrates for the first time an appealing feature of pulsed zero-field magnetic resonance, namely the potential for structure determination in solids without the need for single crystals or oriented samples.

  17. Pulsed-field magnetization of frustrated S = 1/2 Cu(pyrimidine)1.5(H2O)(BF4)2

    Energy Technology Data Exchange (ETDEWEB)

    Manson, J. L. [Chemistry, Eastern Wash. U.; Jasen, D. M. [Chemistry, Eastern Wash. U.; Singleton, John [Los Alamos National Laboratory; Goddard, P. A. [Physics, U. of Warwick

    2017-02-13

    Cu(pym)1.5(H2O)(BF4)2 (pym = pyrimidine) was synthesized and its structure determined by synchrotron single crystal X-ray diffraction. The compound contains S = 1/2 Cu(II) ions arranged in a distorted triangular array (Fig. 1). Each Cu(II) ion is coordinated to three pym ligands, two weakly held BF4- anions and one H2O. To get a sense to the extent (i.e., strength) of possible frustrated exchange interactions in this new compound we measured the magnetization of Cu(pym)1.5(H2O)(BF4)2 in pulsed magnetic fields up to 60 T.

  18. Pulsed Electric Field treatment of packaged food

    NARCIS (Netherlands)

    Roodenburg, B.

    2011-01-01

    Food manufacturers are looking for new preservation techniques that don’t influence the fresh-like characteristics of products. Non-thermal pasteurisation of food with Pulsed Electric Fields (often referred to as PEF) is an emerging technology, where the change of the food is less than with thermal

  19. 脉冲磁场作用下GMAW电弧动态过程分析%Analysis of the Arc Dynamic Process in GMAW Under the Influence of Pulsed Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    白韶军; 陈树君; 刘长辉; 王丽鹏; 黄鹏飞

    2013-01-01

    In the gas metal arc welding process with short circuiting transfer mode has un-regularity,poor arc stability,larger spatter,and poor weld form,the horizontal pulsed auxiliary magnetic field in the short circuiting transfer welding process was established.According to short circuiting transfer period Tc and its coefficient of variation CV,optimize the applied auxiliary magnetic field and the MIG/MAG welding process parameters.The controlled auxiliary magnetic field can reduce both of the arc short circuiting transfer period Tc,and the coefficient of variation CV.When the statistical average of the pulsed magnetic field duration ton take value for the specific welding parameters short circuiting time T1,making short circuiting transfer period tends to be uniform.The experiments show that make the applied magnetic field strength appropriate arc short circuiting transfer period Tc and the coefficient of variation CV lower,it can accelerate the disconnection of the short circuiting transfer liquid bridge,reduce the short circuiting peak welding current,thereby reducing the energy accumulation at the end of the short circuiting transfer,so as to reduce the electrical explosion spatter loss rate of the process and keep the metal transfer stable.%针对熔化极气体保护焊短路过渡焊接过程不均匀、电弧稳定性差、飞溅较大且焊缝成形欠佳的缺点,建立了横向脉冲辅助磁场,使其作用于短路过渡焊接过程的熔滴短路时刻,根据短路过渡周期Tc及变异系数CV,优化了辅助磁场MIG/MAG焊接工艺参数.实验表明:当脉冲磁场持续时间ton取值为特定焊接参数下短路时间T1的统计平均值时,短路过渡周期趋于均匀,电弧短路过渡周期Tc及变异系数CV降低,短路过渡液桥加速断开,短路峰值焊接电流降低,从而使短路过渡末期能量积累以及电爆炸飞溅几率降低,并且使熔滴过渡过程稳定.

  20. Repeating Pulsed Magnet System for Axion-like Particle Searches and Vacuum Birefringence Experiments

    CERN Document Server

    Yamazaki, T; Namba, T; Asai, S; Kobayashi, T; Matsuo, A; Kindo, K; Nojiri, H

    2016-01-01

    We have developed a repeating pulsed magnet system which generates magnetic fields of about 10 T in a direction transverse to an incident beam over a length of 0.8 m with a repetition rate of 0.2 Hz. Its repetition rate is by two orders of magnitude higher than usual pulsed magnets. It is composed of four low resistance racetrack coils and a 30 kJ transportable capacitor bank as a power supply. The system aims at axion-like particle searches with a pulsed light source and vacuum birefringence measurements. We report on the details of the system and its performances.

  1. Repeating pulsed magnet system for axion-like particle searches and vacuum birefringence experiments

    Science.gov (United States)

    Yamazaki, T.; Inada, T.; Namba, T.; Asai, S.; Kobayashi, T.; Matsuo, A.; Kindo, K.; Nojiri, H.

    2016-10-01

    We have developed a repeating pulsed magnet system which generates magnetic fields of about 10 T in a direction transverse to an incident beam over a length of 0.8 m with a repetition rate of 0.2 Hz. Its repetition rate is by two orders of magnitude higher than usual pulsed magnets. It is composed of four low resistance racetrack coils and a 30 kJ transportable capacitor bank as a power supply. The system aims at axion-like particle searches with a pulsed light source and vacuum birefringence measurements. We report on the details of the system and its performances.

  2. Vestibular stimulation by magnetic fields

    Science.gov (United States)

    Ward, Bryan K.; Roberts, Dale C.; Della Santina, Charles C.; Carey, John P.; Zee, David S.

    2015-01-01

    Individuals working next to strong static magnetic fields occasionally report disorientation and vertigo. With the increasing strength of magnetic fields used for magnetic resonance imaging (MRI) studies, these reports have become more common. It was recently learned that humans, mice and zebrafish all demonstrate behaviors consistent with constant peripheral vestibular stimulation while inside a strong, static magnetic field. The proposed mechanism for this effect involves a Lorentz force resulting from the interaction of a strong static magnetic field with naturally occurring ionic currents flowing through the inner ear endolymph into vestibular hair cells. The resulting force within the endolymph is strong enough to displace the lateral semicircular canal cupula, inducing vertigo and the horizontal nystagmus seen in normal mice and in humans. This review explores the evidence for interactions of magnetic fields with the vestibular system. PMID:25735662

  3. Magnetic response to applied electrostatic field in external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Adorno, T.C. [Universidade de Sao Paulo, Instituto de Fisica, Caixa Postal 66318, Sao Paulo, SP (Brazil); University of Florida, Department of Physics, Gainesville, FL (United States); Gitman, D.M. [Universidade de Sao Paulo, Instituto de Fisica, Caixa Postal 66318, Sao Paulo, SP (Brazil); Tomsk State University, Department of Physics, Tomsk (Russian Federation); Shabad, A.E. [P. N. Lebedev Physics Institute, Moscow (Russian Federation)

    2014-04-15

    We show, within QED and other possible nonlinear theories, that a static charge localized in a finite domain of space becomes a magnetic dipole, if it is placed in an external (constant and homogeneous) magnetic field in the vacuum. The magnetic moment is quadratic in the charge, depends on its size and is parallel to the external field, provided the charge distribution is at least cylindrically symmetric. This magneto-electric effect is a nonlinear response of the magnetized vacuum to an applied electrostatic field. Referring to the simple example of a spherically symmetric applied field, the nonlinearly induced current and its magnetic field are found explicitly throughout the space; the pattern of the lines of force is depicted, both inside and outside the charge, which resembles that of a standard solenoid of classical magnetostatics. (orig.)

  4. Magnetic response to applied electrostatic field in external magnetic field

    CERN Document Server

    Adorno, T C; Shabad, A E

    2014-01-01

    We show, within QED and other possible nonlinear theories, that a static charge localized in a finite domain of space becomes a magnetic dipole, if it is placed in an external (constant and homogeneous) magnetic field in the vacuum. The magnetic moment is quadratic in the charge, depends on its size and is parallel to the external field, provided the charge distribution is at least cylindrically symmetric. This magneto-electric effect is a nonlinear response of the magnetized vacuum to an applied electrostatic field. Referring to a simple example of a spherically-symmetric applied field, the nonlinearly induced current and its magnetic field are found explicitly throughout the space, the pattern of lines of force is depicted, both inside and outside the charge, which resembles that of a standard solenoid of classical magnetostatics.

  5. Biofouling prevention with pulsed electric fields

    Energy Technology Data Exchange (ETDEWEB)

    Abou-Ghazala, A.; Schoenbach, K.H.

    2000-02-01

    Temporary immobilization of aquatic nuisance species through application of short electric pulses has been explored as a method to prevent biofouling in cooling water systems where untreated lake, river, or sea water is used. In laboratory experiments, electrical pulses with amplitudes on the order of kilovolts/centimeter and submicrosecond duration were found to be most effective in stunning time in a temporal range from minutes to hours. The temporary immobilization is assumed to be caused by reversible membrane breakdown. This assumption is supported by results of measurements of the energy required for stunning. Based on the data obtained in laboratory experiments, field experiments in a tidal water environment have been performed. The flow velocity was such that the residence time of the aquatic nuisance species in the system was approximately half a minute. The results showed that the pulsed electric field method provides full protection against biofouling when pulses of 0.77 {micro}s width and 6 kV/cm amplitude are applied to the water at the inlet of such a cooling water system. Even at amplitudes of 1 kV/cm, the protection is still in the 90% range, at an energy expenditure of 1 kWh for the treatment of 60,000 gallons of water.

  6. The MAVEN Magnetic Field Investigation

    Science.gov (United States)

    Connerney, J. E. P.; Espley, J.; Lawton, P.; Murphy, S.; Odom, J.; Oliversen, R.; Sheppard, D.

    2014-01-01

    The MAVEN magnetic field investigation is part of a comprehensive particles and fields subsystem that will measure the magnetic and electric fields and plasma environment of Mars and its interaction with the solar wind. The magnetic field instrumentation consists of two independent tri-axial fluxgate magnetometer sensors, remotely mounted at the outer extremity of the two solar arrays on small extensions ("boomlets"). The sensors are controlled by independent and functionally identical electronics assemblies that are integrated within the particles and fields subsystem and draw their power from redundant power supplies within that system. Each magnetometer measures the ambient vector magnetic field over a wide dynamic range (to 65,536 nT per axis) with a quantization uncertainty of 0.008 nT in the most sensitive dynamic range and an accuracy of better than 0.05%. Both magnetometers sample the ambient magnetic field at an intrinsic sample rate of 32 vector samples per second. Telemetry is transferred from each magnetometer to the particles and fields package once per second and subsequently passed to the spacecraft after some reformatting. The magnetic field data volume may be reduced by averaging and decimation, when necessary to meet telemetry allocations, and application of data compression, utilizing a lossless 8-bit differencing scheme. The MAVEN magnetic field experiment may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. A spacecraft magnetic control program was implemented to provide a magnetically clean environment for the magnetic sensors and the MAVEN mission plan provides for occasional spacecraft maneuvers - multiple rotations about the spacecraft x and z axes - to characterize spacecraft fields and/or instrument offsets in flight.

  7. Experimental Investigation of Stochastic Pulsation and Formation of Light Bullets with Megagauss Magnetic Fields by an Intense Laser Pulse Propagating in a Preionized Plasma

    Science.gov (United States)

    Vogel, Nadja I.; Kochan, N.

    2001-01-01

    The generation of extremely stable light bullets in a preformed plasma near critical density has been observed experimentally during the interaction of intense picosecond laser beam with a metallic target in air. Optical probing measurements indicate the formation of pulsating channels, typically of about 5 μm in diameter, directed towards a heating laser beam, as well as of disconnected massive plasma blocks moving also towards the laser beam. The velocities of the dense plasma blocks reach the values of 4.5×108 cm/s. The blocks are stable during their acceleration and propagation in air. Self-generated magnetic fields up to 4-7 MG were observed by means of the Faraday rotation of a probe laser beam.

  8. Magnetic field effect on spoke behaviour

    Science.gov (United States)

    Hnilica, Jaroslav; Slapanska, Marta; Klein, Peter; Vasina, Petr

    2016-09-01

    The investigations of the non-reactive high power impulse magnetron sputtering (HiPIMS) discharge using high-speed camera imaging, optical emission spectroscopy and electrical probes showed that plasma is not homogeneously distributed over the target surface, but it is concentrated in regions of higher local plasma density called spokes rotating above the erosion racetrack. Magnetic field effect on spoke behaviour was studied by high-speed camera imaging in HiPIMS discharge using 3 inch titanium target. An employed camera enabled us to record two successive images in the same pulse with time delay of 3 μs between them, which allowed us to determine the number of spokes, spoke rotation velocity and spoke rotation frequency. The experimental conditions covered pressure range from 0.15 to 5 Pa, discharge current up to 350 A and magnetic fields of 37, 72 and 91 mT. Increase of the magnetic field influenced the number of spokes observed at the same pressure and at the same discharge current. Moreover, the investigation revealed different characteristic spoke shapes depending on the magnetic field strength - both diffusive and triangular shapes were observed for the same target material. The spoke rotation velocity was independent on the magnetic field strength. This research has been financially supported by the Czech Science Foundation in frame of the project 15-00863S.

  9. Reducing blood viscosity with magnetic fields.

    Science.gov (United States)

    Tao, R; Huang, K

    2011-07-01

    Blood viscosity is a major factor in heart disease. When blood viscosity increases, it damages blood vessels and increases the risk of heart attacks. Currently, the only method of treatment is to take drugs such as aspirin, which has, however, several unwanted side effects. Here we report our finding that blood viscosity can be reduced with magnetic fields of 1 T or above in the blood flow direction. One magnetic field pulse of 1.3 T lasting ~1 min can reduce the blood viscosity by 20%-30%. After the exposure, in the absence of magnetic field, the blood viscosity slowly moves up, but takes a couple of hours to return to the original value. The process is repeatable. Reapplying the magnetic field reduces the blood viscosity again. By selecting the magnetic field strength and duration, we can keep the blood viscosity within the normal range. In addition, such viscosity reduction does not affect the red blood cells' normal function. This technology has much potential for physical therapy.

  10. Nonlinear Magnetoelectric Response of Planar Ferromagnetic-Piezoelectric Structures to Sub-Millisecond Magnetic Pulses

    Directory of Open Access Journals (Sweden)

    Mikhail Shamonin

    2012-11-01

    Full Text Available The magnetoelectric response of bi- and symmetric trilayer composite structures to pulsed magnetic fields is experimentally investigated in detail. The structures comprise layers of commercially available piezoelectric (lead zirconate titanate and magnetostrictive (permendur or nickel materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 µs and amplitudes ranging from 500 Oe to 38 kOe. The time dependence of the resulting voltage is presented and explained by theoretical estimations. Appearance of voltage oscillations with frequencies much larger than the reciprocal pulse length is observed for sufficiently large amplitudes (~1–10 kOe of the magnetic-field pulse. The origin of these oscillations is the excitation of bending and planar acoustic oscillations in the structures. Dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated by digital signal processing and compared with those obtained by the method of harmonic field modulation. The results are of interest for developing magnetoelectric sensors of pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.

  11. Iridate compound produces extraordinarily high coercive magnetic field

    Science.gov (United States)

    Zapf, Vivien; Topping, Craig; Kim, Jae-Wook; Mun, Eun-Deok; Goddard, Paul; Ghannadzadeh, Saman; Luo, Xuan; Cheong, Sang-Wook; Singleton, John

    2014-03-01

    We present a data on an iridate compound that shows an extraordinarily large magnetic hysteresis loop. The coercive magnetic field exceeds 40 Tesla in single-crystal samples. The hysteresis coexists with a linear background, and the total remanent magnetization is about half a Bohr magneton. We will discuss the emergence of these properties from the interplay of spin-orbit coupling, magnetic exchange and possible frustration. The single crystalline material exhibits a magnetic hysteresis loop for one orientation of the magnetic field and a smooth linear increase in the magnetization with field for the other. Measurements were conducted in 65 T short-pulse magnets and the 60 Tesla shaped-pulse magnet at the National High Magnetic Field Lab in Los Alamos. We do not observe any dependence of the magnetic hysteresis on magnetic field sweep rate. Compounds containing Ir4 + have attracted attention recently due to strong spin-orbit coupling that competes with crystal-electric field and exchange interactions. This competition can result in non-Hund's-rule ground states with unusual properties.

  12. Pulsed photoelectric field emission from needle cathodes

    CERN Document Server

    Hernandez-Garcia, C

    2002-01-01

    Experiments have been carried out to measure the current emitted by tungsten needles with 1-mu m tip radius operated up to 50 kV. This corresponds to electric fields in the order of 10 sup 9 to 10 sup 1 sup 0 V/m. The needles were illuminated with 10-ns laser pulses at 532, 355 and 266 nm. The laser intensity was varied from 10 sup 1 sup 0 to 10 sup 1 sup 2 W/m sup 2 , limited by damage to the needle tip. The observed quantum efficiency depends on the wavelength and the electric field, approaching unity at the highest electric fields when illuminated at 266 nm. Peak currents up to 100 mA were observed in nanosecond pulses, corresponding to an estimated brightness of 10 sup 1 sup 6 A/m sup 2 sr. Since the current is controlled by the laser intensity, with only a weak voltage dependence, these cathodes can be used for infrared and ultraviolet tabletop free-electron lasers and other applications that demand short electron-beam pulses with high brightness.

  13. A Magnetic Resonance Measurement Technique for Rapidly Switched Gradient Magnetic Fields in a Magnetic Resonance Tomograph

    Directory of Open Access Journals (Sweden)

    K. Bartušek

    2003-01-01

    Full Text Available This paper describes a method for measuring of the gradient magnetic field in Nuclear Magnetic Resonance (NMR tomography, which is one of the modern medical diagnostic methods. A very important prerequisite for high quality imaging is a gradient magnetic field in the instrument with exactly defined properties. Nuclear magnetic resonance enables us to measure the pulse gradient magnetic field characteristics with high accuracy. These interesting precise methods were designed, realised, and tested at the Institute of Scientific Instruments (ISI of the Academy of Sciences of the Czech Republic. The first of them was the Instantaneous Frequency (IF method, which was developed into the Instantaneous Frequency of Spin Echo (IFSE and the Instantaneous Frequency of Spin Echo Series (IFSES methods. The above named methods are described in this paper and their a comparison is also presented.

  14. Magnetic fields in ring galaxies

    CERN Document Server

    Moss, D; Silchenko, O; Sokoloff, D; Horellou, C; Beck, R

    2016-01-01

    Many galaxies contain magnetic fields supported by galactic dynamo action. However, nothing definitive is known about magnetic fields in ring galaxies. Here we investigate large-scale magnetic fields in a previously unexplored context, namely ring galaxies, and concentrate our efforts on the structures that appear most promising for galactic dynamo action, i.e. outer star-forming rings in visually unbarred galaxies. We use tested methods for modelling $\\alpha-\\Omega$ galactic dynamos, taking into account the available observational information concerning ionized interstellar matter in ring galaxies. Our main result is that dynamo drivers in ring galaxies are strong enough to excite large-scale magnetic fields in the ring galaxies studied. The variety of dynamo driven magnetic configurations in ring galaxies obtained in our modelling is much richer than that found in classical spiral galaxies. In particular, various long-lived transients are possible. An especially interesting case is that of NGC 4513 where th...

  15. Rotating superconductor magnet for producing rotating lobed magnetic field lines

    Science.gov (United States)

    Hilal, Sadek K.; Sampson, William B.; Leonard, Edward F.

    1978-01-01

    This invention provides a rotating superconductor magnet for producing a rotating lobed magnetic field, comprising a cryostat; a superconducting magnet in the cryostat having a collar for producing a lobed magnetic field having oppositely directed adjacent field lines; rotatable support means for selectively rotating the superconductor magnet; and means for energizing the superconductor magnet.

  16. Low Cost Magnetic Field Controller

    CERN Document Server

    Malafronte, Alexandre A

    2005-01-01

    The Physics Institute of the University of São Paulo (IFUSP) is building a continuous wave (cw) racetrack microtron. This machine has several dipole magnets, like the first and second stage recirculators, and a number of smaller ones in the transport line. These magnets must produce very stable magnetic fields to allow the beam to recirculate along very precise orbits and paths. Furthermore, the fields must be reproducible with great accuracy to allow an easier setup of the machine, though the effects of hysteresis tend to jeopardize the reproducibility. If the magnetic field is chosen by setting the current in the coils, temperature effects over the magnet and power supply tend to change the field. This work describes an inexpensive magnetic field controller that allows a direct measure of the magnetic field through an Hall probe. It includes a microcontroller running a feedback algorithm to control the power supply, in order to keep the field stable and reproducible. The controller can also execu...

  17. Resonant magnetic fields from inflation

    CERN Document Server

    Byrnes, Christian T; Jain, Rajeev Kumar; Urban, Federico R

    2012-01-01

    We propose a novel scenario to generate primordial magnetic fields during inflation induced by an oscillating coupling of the electromagnetic field to the inflaton. This resonant mechanism has two key advantages over previous proposals. First of all, it generates a narrow band of magnetic fields at any required wavelength, thereby allaying the usual problem of a strongly blue spectrum and its associated backreaction. Secondly, it avoids the need for a strong coupling as the coupling is oscillating rather than growing or decaying exponentially. Despite these major advantages, we find that the backreaction is still far too large during inflation if the generated magnetic fields are required to have a strength of ${\\cal O}(10^{-15}\\, \\Gauss)$ today on observationally interesting scales. We provide a more general no-go argument, proving that this problem will apply to any model in which the magnetic fields are generated on subhorizon scales and freeze after horizon crossing.

  18. Static magnetic fields enhance turbulence

    CERN Document Server

    Pothérat, Alban

    2015-01-01

    More often than not, turbulence occurs under the influence of external fields, mostly rotation and magnetic fields generated either by planets, stellar objects or by an industrial environment. Their effect on the anisotropy and the dissipative behaviour of turbulence is recognised but complex, and it is still difficult to even tell whether they enhance or dampen turbulence. For example, externally imposed magnetic fields suppress free turbulence in electrically conducting fluids (Moffatt 1967), and make it two-dimensional (2D) (Sommeria & Moreau 1982); but their effect on the intensity of forced turbulence, as in pipes, convective flows or otherwise, is not clear. We shall prove that since two-dimensionalisation preferentially affects larger scales, these undergo much less dissipation and sustain intense turbulent fluctuations. When higher magnetic fields are imposed, quasi-2D structures retain more kinetic energy, so that rather than suppressing forced turbulence, external magnetic fields indirectly enha...

  19. Anomalous magnetic behaviour of NdCu 2 in high magnetic fields

    Science.gov (United States)

    Doerr, M.; Kramp, S.; Loewenhaupt, M.; Rotter, M.; Kratz, R.; Krug, H.; Eckert, D.; Siegel, H.; Verges, P.

    2001-01-01

    Some of the RCu 2 compounds (R=Ce,Pr,Tb,Dy) with easy a-axis show an irreversible change of the easy axis into the c-direction in high magnetic fields. This metamagnetic “axis conversion” is caused by a strong magneto-elastic coupling in the ac-plane. With NdCu 2 a similar magnetic behaviour was found for the first time in a system with an easy axis perpendicular to the ac-plane. We present results of magnetization in static magnetic fields up to 14 T. The minimum conversion field is μ0Hcrit=12.5 T which is higher than in the other compounds. At low temperatures the magnetic axis conversion coincides with the transition into the induced ferromagnetic state. Magnetization measurements were also carried out in pulsed fields up to 50 T. They show an almost linear increase of the conversion fields with temperature which gives a strong evidence that the conversion is caused by an effective quadrupolar coupling. In addition, comparing the results of static and pulsed field experiments, an influence of field duration on the conversion process was found. The high-precision pulsed field magnetization experiments were done in the Dresden high magnetic field facility (HLD).

  20. Origin of cosmic magnetic fields

    Science.gov (United States)

    Rees, M. J.

    2006-06-01

    The first significant cosmic fields, and the seed field for galactic dynamos probably developed after the formation of the first non-linear structures. The history of star formation and the intergalactic medium is controlled, at least in part, by how and when galaxies and their precursors acquired their fields. The amplification of fields behind shocks, and the diffusivity of the magnetic flux, are crucial to the interpretation of radio sources, gamma ray burst afterglows, and other energetic cosmic phenomena. The build-up of magnetic fields is an important aspect of the overall cosmogonic process.

  1. Optical Signatures from Magnetic 2-D Electron Gases in High Magnetic Fields to 60 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Crooker, S.A.; Kikkawa, J.M.; Awschalom, D.D.; Smorchikova, I.P.; Samarth, N.

    1998-11-08

    We present experiments in the 60 Tesla Long-Pulse magnet at the Los Alamos National High Magnetic Field Lab (NHMFL) focusing on the high-field, low temperature photoluminescence (PL) from modulation-doped ZnSe/Zn(Cd,Mn)Se single quantum wells. High-speed charge-coupled array detectors and the long (2 second) duration of the magnet pulse permit continuous acquisition of optical spectra throughout a single magnet shot. High-field PL studies of the magnetic 2D electron gases at temperatures down to 350mK reveal clear intensity oscillations corresponding to integer quantum Hall filling factors, from which we determine the density of the electron gas. At very high magnetic fields, steps in the PL energy are observed which correspond to the partial unlocking of antiferromagnetically bound pairs of Mn2+ spins.

  2. Study of the reduced magnetic field required for thermally assisted magnetization reversal

    Science.gov (United States)

    Firdausi, H. F. Y.; Utari; Purnama, B.

    2016-11-01

    The reduced magnetic field required for thermally magnetization reversal discussed in this paper. Study of thermally assisted magnetization reversal conduct by using micromagnetic simulation. The magnetic dot size of the simulation was 50 nm × 50 nm × 20 nm. The perpendicularly anisotropy constant was 2 × 106 erg/cm3. Initial condition was set single domain configuration. Then a sufficiently thermal pulse was used to get stochastic effect so that the magnetization along to the induce field direction for pico second duration. The results show that the reduced magnetic field mechanism seem to be temporary antiferromagnetic configuration before single domain configuration in alinging along to field direction. The same mechanims observed for modify of thickness dot particles. The require magnetic field of 145 Oe in thermally assisted magnetization reversal open a posibility for MRAM application.

  3. Analysis and Optimisation of Pulse Dynamics for Magnetic Stimulation

    CERN Document Server

    Goetz, Stefan M; Gerhofer, Manuel G; Weyh, Thomas; Herzog, Hans-Georg

    2011-01-01

    Magnetic stimulation is a standard tool in brain research and many fields of neurology, as well as psychiatry. From a physical perspective, one key aspect of this method is the inefficiency of available setups. Whereas the spatial field properties have been studied rather intensively with coil designs, the dynamics have been neglected almost completely for a long time. Instead, the devices and their technology defined the waveform. Here, an analysis of the waveform space is performed. Based on these data, an appropriate optimisation approach is outlined which makes use of a modern nonlinear axon description of a mammalian motor nerve. The approach is based on a hybrid global-local method; different coordinate systems for describing the continuous waveforms in a limited parameter space are defined for sufficient stability. The results of the numeric setup suggest that there is plenty of room for waveforms with higher efficiency than the traditional shapes. One class of such pulses is analysed further. Although...

  4. Measuring Earth's Magnetic Field Simply.

    Science.gov (United States)

    Stewart, Gay B.

    2000-01-01

    Describes a method for measuring the earth's magnetic field using an empty toilet paper tube, copper wire, clear tape, a battery, a linear variable resistor, a small compass, cardboard, a protractor, and an ammeter. (WRM)

  5. What Are Electric and Magnetic Fields? (EMF)

    Science.gov (United States)

    ... take for granted. What are electric and magnetic fields? Electric and magnetic fields (EMF) are invisible lines of ... humans. AC electric power produces electric and magnetic fields that create weak electric currents in humans. Being exposed to some kinds ...

  6. Development of ultra-short high voltage pulse technology using magnetic pulse compression

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Byung Heon; Kim, S. G.; Nam, S. M.; Lee, B. C.; Lee, S. M.; Jeong, Y. U.; Cho, S. O.; Jin, J. T.; Choi, H. L

    1998-01-01

    The control circuit for high voltage switches, the saturable inductor for magnetic assist, and the magnetic pulse compression circuit were designed, constructed, and tested. The core materials of saturable inductors in magnetic pulse compression circuit were amorphous metal and ferrite and total compression stages were 3. By the test, in high repetition rate, high pulse compression were certified. As a result of this test, it became possible to increase life-time of thyratrons and to replace thyratrons by solid-state semiconductor switches. (author). 16 refs., 16 tabs.

  7. The Juno Magnetic Field Investigation

    Science.gov (United States)

    Connerney, J. E. P.; Benn, M.; Bjarno, J. B.; Denver, T.; Espley, J.; Jorgensen, J. L.; Jorgensen, P. S.; Lawton, P.; Malinnikova, A.; Merayo, J. M.; Murphy, S.; Odom, J.; Oliversen, R.; Schnurr, R.; Sheppard, D.; Smith, E. J.

    2017-02-01

    The Juno Magnetic Field investigation (MAG) characterizes Jupiter's planetary magnetic field and magnetosphere, providing the first globally distributed and proximate measurements of the magnetic field of Jupiter. The magnetic field instrumentation consists of two independent magnetometer sensor suites, each consisting of a tri-axial Fluxgate Magnetometer (FGM) sensor and a pair of co-located imaging sensors mounted on an ultra-stable optical bench. The imaging system sensors are part of a subsystem that provides accurate attitude information (to ˜20 arcsec on a spinning spacecraft) near the point of measurement of the magnetic field. The two sensor suites are accommodated at 10 and 12 m from the body of the spacecraft on a 4 m long magnetometer boom affixed to the outer end of one of 's three solar array assemblies. The magnetometer sensors are controlled by independent and functionally identical electronics boards within the magnetometer electronics package mounted inside Juno's massive radiation shielded vault. The imaging sensors are controlled by a fully hardware redundant electronics package also mounted within the radiation vault. Each magnetometer sensor measures the vector magnetic field with 100 ppm absolute vector accuracy over a wide dynamic range (to 16 Gauss = 1.6 × 106 nT per axis) with a resolution of ˜0.05 nT in the most sensitive dynamic range (±1600 nT per axis). Both magnetometers sample the magnetic field simultaneously at an intrinsic sample rate of 64 vector samples per second. The magnetic field instrumentation may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. The attitude determination system compares images with an on-board star catalog to provide attitude solutions (quaternions) at a rate of up to 4 solutions per second, and may be configured to acquire images of selected targets for science and engineering analysis. The system tracks and catalogs objects that pass through the imager field of

  8. The Juno Magnetic Field Investigation

    Science.gov (United States)

    Connerney, J. E. P.; Benna, M.; Bjarno, J. B.; Denver, T.; Espley, J.; Jorgensen, J. L.; Jorgensen, P. S.; Lawton, P.; Malinnikova, A.; Merayo, J. M.; hide

    2017-01-01

    The Juno Magnetic Field investigation (MAG) characterizes Jupiter's planetary magnetic field and magnetosphere, providing the first globally distributed and proximate measurements of the magnetic field of Jupiter. The magnetic field instrumentation consists of two independent magnetometer sensor suites, each consisting of a tri-axial Fluxgate Magnetometer (FGM) sensor and a pair of co-located imaging sensors mounted on an ultra-stable optical bench. The imaging system sensors are part of a subsystem that provides accurate attitude information (to approx. 20 arcsec on a spinning spacecraft) near the point of measurement of the magnetic field. The two sensor suites are accommodated at 10 and 12 m from the body of the spacecraft on a 4 m long magnetometer boom affixed to the outer end of one of 's three solar array assemblies. The magnetometer sensors are controlled by independent and functionally identical electronics boards within the magnetometer electronics package mounted inside Juno's massive radiation shielded vault. The imaging sensors are controlled by a fully hardware redundant electronics package also mounted within the radiation vault. Each magnetometer sensor measures the vector magnetic field with 100 ppm absolute vector accuracy over a wide dynamic range (to 16 Gauss = 1.6 x 10(exp. 6) nT per axis) with a resolution of approx. 0.05 nT in the most sensitive dynamic range (+/-1600 nT per axis). Both magnetometers sample the magnetic field simultaneously at an intrinsic sample rate of 64 vector samples per second. The magnetic field instrumentation may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. The attitude determination system compares images with an on-board star catalog to provide attitude solutions (quaternions) at a rate of up to 4 solutions per second, and may be configured to acquire images of selected targets for science and engineering analysis. The system tracks and catalogs objects that pass through

  9. Clinical update of pulsed electromagnetic fields on osteoporosis

    Institute of Scientific and Technical Information of China (English)

    HUANG Li-qun; HE Hong-chen; HE Cheng-qi; CHEN Jian; YANG Lin

    2008-01-01

    Objective To understand the effects of low-frequency pulsed electromagnetic fields (PEMFs) on chronic bony pain,bone mineral density (BMD), bone strength and biochemical markers of bone metabolism in the patients of osteoporosis.Data sources Using the key words "pulsed electromagnetic fields" and "osteoporosis", we searched the PubMed for related studies published in English from January 1996 to December 2007. We also searched the China National Knowledge Infrastructure (CNKI) for studies published in Chinese from January 1996 to December 2007.Study selection Inclusion criteria: (1) all articles which referred to the effects of low-frequency pulsed magnetic fields on osteoporosis either in primary osteoporosis or secondary osteoporosis; (2) either observational studies or randomized controlled studies. Exclusion criteria: (1) articles on experimental studies about osteoporosis; (2) repetitive studies; (3)case reports; (4) meta analysis.Results Totally 111 related articles were collected, 101 of them were published in Chinese, 10 were in English.Thirty-four were included and the remaining 84 were excluded.Conclusions Low-frequency PEMFs relieves the pain of primary osteoporosis quickly and efficiently, enhances bone formation and increases BMD of secondary osteoporosis. But the effects of PEMFs on bone mineral density of primary osteoporosis and bone resorption were controversial.

  10. Effects of Pulsed Electromagnetic Fields on Osteoporosis Model

    Science.gov (United States)

    Xiaowei, Yang; Liming, Wang; Guan, Z. C.; Yaou, Zhang; Xiangpeng, Wang

    The purpose of this paper was to investigate the preventive effects and long term effects of extremely low frequency pulsed electromagnetic fields (PEMFs), generated by circular coils and pulsed electromagnetic fields stimulators, on osteoporosis in bilaterally ovariectomized rats. In preventive experiment, thirty three-month old female Sprague-Dawley rats were randomly divided into three different groups: sham (SHAM), ovariectomy (OVX), PEMFs stimulation (PEMFs). All rats were subjected to bilaterally ovariectomy except those in SHAM group. The PEMFs group was exposed to pulsed electromagnetic fields with frequency 15 Hz, peak magnetic induction density 2.2mT and exposure time 2 hours per day. The bone mineral density (BMD) of vertebra and left femur were measured by dual energy X-ray absorptiometry at eighth week, twelfth week and sixteenth week after surgery. In long term effects experiment, forty four rats were randomly divided into sham (14 rats, SHAM), ovariectomy group (10 rats, OVX), 15Hz PEMFs group(10 rats, 15Hz) and 30Hz PEMFs group(10 rats, 30Hz) at twenty-sixth week after surgery. Rats in PEMFs groups were stimulated sixteen weeks. In preventive experiment, the Corrected BMD of vertebra and femur was significantly higher than that of OVX group after 16 weeks (Ptreatment of osteoporosis.

  11. 低频脉冲磁场对大鼠心肌微血管内皮细胞的影响%Effects of low frequency pulsed magnetic fields on cardiac microvascular endothelial cells

    Institute of Scientific and Technical Information of China (English)

    郭影; 李飞; 郭文怡; 孙冬冬; 路晓艳; 张荣庆

    2010-01-01

    Objective To investigate the effects of low frequency pulsed magnetic fields (LF-PMFs) on the proliferation of cardiac microvascular endothelial cells (CMECs) and their ultrastructure,migration and angiogenic potential. Methods CMECs from rats were exposed in vitro to low frequency square wave pulsed magnetic fields (15 Hz) 2 h/d for 5 d.The cells were randomly divided into 4 groups (control,1.0 mT,1.4 mT and 1.8 mT).After 5 days of exposure,proliferation was detected in terms of the cells' growth curves,their cycle was detected with flow cytometry,and their ultrastructure was observed using transmission electric microscopy. A scratch assay was used to evaluate the CMECs migration,and their angiogenic potential was measured using a tube formation assay.Results There was no significant effect of a 1.0 mT magnetic field on the ceils' growth curve,cell cycle or ultrastructure.The 1.4 mT magnetic field did,however,accelerate the CMECs' proliferation.The peak of the cells'growth curve was higher and moved forward,and the percentage of cells in the S phase increased significantly compared with the control group.The effects of a 1.8 mT magnetic field on S phase development were similar to those of the 1.4 mT field,but the peak of the cells' growth curve was not moved forward.After exposure to a 1.4 mT or 1.8 mT magnetic field,the CMECs' ultrastructure changed and they appeared more viable and powerful.Their nucleoil became bigger and clearer than those of the control group.There were cavernous nucleoli or two nucleoli.The number of mitochondria increased.The endoplasmic reticulum was richer and full of protein secretions inside with many microvilli on the surface.The magnetic fields facilitated migration and tube formation in the CMECs significantly,and these effects were correlated with the magnetic field intensity (1.4 mT> 1.8 mT > 1.0 mT).The cell migratory percentage in the 1.4 mT group was 86.1% ,while in the control group it was only 45.3%.When the CMECs were

  12. The influence of laser pulse on the photoabsorption spectra of Li atom in strong external field

    Institute of Scientific and Technical Information of China (English)

    WANG; Dehua; LIN; Shenglu

    2006-01-01

    Using the time-dependent perturbation theory and the calculation formula of the single- and double-pulse absorption spectra of the atom in strong external fields, we calculate the single- and double-pulse absorption spectra of Li atom in strong magnetic field for different pulse widths. The results show that a pulse of some width can reduce the contribution of the short period closed orbits and eliminate the contribution of the long period orbits. Compared with the single-pulse absorption spectra, we found that for some phase differences, the double-pulse laser absorption spectra are strengthened; while for others, they are reduced. Therefore, we can use the pulse laser to control the oscillation of the absorption spectra and obtain the optimization object.

  13. Interleaving Gradient Magnetic Field Method for Diffusion Weighted Spectroscopy

    Institute of Scientific and Technical Information of China (English)

    GAO Song; ZU Zhong-Liang; BAO Shang-Lian

    2008-01-01

    Diffusion-weighted magnetic resonance spectroscopy(DWS)has considerable potential in clinical and research applications.However.it is seldom implemented in conventional magnetic resonance imaging(MRI)scanners due to the strict hardware requirements.We propose an interleaving gradient magnetic field(IGMF)method based on point resolved spectroscopy(PRESS).Four interlaced powerful diffusion sensitive gradient magnetic fields are positioned around the two πrefocusing rf pulses in the PRESS sequence.This method utilizes the interval time in the PRESS pulse sequence,doubles the duration time of the diffusion sensitive gradient magnetic field and decreases the detrimental effect of the induced eddy current.The results of theoretical analysis and experimental observation demonstrate that the IGMF method is suitable for conventional MRI scanners.

  14. Nuclear magnetic resonance at millitesla fields using a zero-field spectrometer

    Science.gov (United States)

    Tayler, Michael C. D.; Sjolander, Tobias F.; Pines, Alexander; Budker, Dmitry

    2016-09-01

    We describe new analytical capabilities for nuclear magnetic resonance (NMR) experiments in which signal detection is performed with chemical resolution (via spin-spin J couplings) in the zero to ultra-low magnetic field region, below 1 μT. Using magnetic fields in the 100 μT to 1 mT range, we demonstrate the implementation of conventional NMR pulse sequences with spin-species selectivity.

  15. Theory of pulsed reaction yield detected magnetic resonance

    NARCIS (Netherlands)

    Nasibulov, E.A.; Kulik, L.V.; Kaptein, R.; Ivanov, K.L.

    2012-01-01

    We propose pulse sequences for Reaction Yield Detected Magnetic Resonance (RYDMR), which are based on refocusing the zero-quantum coherences in radical pairs by non-selective microwave pulses and using the population of a radical pair singlet spin state as an observable. The new experiments are

  16. Magnetic fields in spiral galaxies

    Science.gov (United States)

    Beck, Rainer

    2015-12-01

    Radio synchrotron emission, its polarization and Faraday rotation of the polarization angle are powerful tools to study the strength and structure of magnetic fields in galaxies. Unpolarized synchrotron emission traces isotropic turbulent fields which are strongest in spiral arms and bars (20-30 \\upmu G) and in central starburst regions (50-100 \\upmu G). Such fields are dynamically important; they affect gas flows and drive gas inflows in central regions. Polarized emission traces ordered fields, which can be regular or anisotropic turbulent, where the latter originates from isotropic turbulent fields by the action of compression or shear. The strongest ordered fields (10-15 \\upmu G) are generally found in interarm regions. In galaxies with strong density waves, ordered fields are also observed at the inner edges of spiral arms. Ordered fields with spiral patterns exist in grand-design, barred and flocculent galaxies and in central regions. Ordered fields in interacting galaxies have asymmetric distributions and are a tracer of past interactions between galaxies or with the intergalactic medium.—Faraday rotation measures of the diffuse polarized radio emission from galaxy disks reveal large-scale spiral patterns that can be described by the superposition of azimuthal modes; these are signatures of regular fields generated by mean-field dynamos. "Magnetic arms" between gaseous spiral arms may also be products of dynamo action, but need a stable spiral pattern to develop. Helically twisted field loops winding around spiral arms were found in two galaxies so far. Large-scale field reversals, like the one found in the Milky Way, could not yet be detected in external galaxies. In radio halos around edge-on galaxies, ordered magnetic fields with X-shaped patterns are observed. The origin and evolution of cosmic magnetic fields, in particular their first occurrence in young galaxies and their dynamical importance during galaxy evolution, will be studied with

  17. Nanometric alternating magnetic field generator.

    Science.gov (United States)

    Espejo, A P; Tejo, F; Vidal-Silva, N; Escrig, J

    2017-07-05

    In this work we introduce an alternating magnetic field generator in a cylindrical nanostructure. This field appears due to the rotation of a magnetic domain wall located at some position, generating a magnetic region that varies its direction of magnetization alternately, thus inducing an alternating magnetic flux in its vicinity. This phenomenon occurs due to the competition between a spin-polarized current and a magnetic field, which allows to control both the angular velocity and the pinning position of the domain wall. As proof of concept, we study the particular case of a diameter-modulated nanowire with a spin-polarized current along its axis and the demagnetizing field produced by its modulation. This inhomogeneous field allows one to control the angular velocity of the domain wall as a function of its position along the nanowire allowing frequencies in the GHz range to be achieved. This generator could be used in telecommunications for devices in the range of radiofrequencies or, following Faraday's induction law, could also induce an electromotive force and be used as a movable alternate voltage source in future nanodevices.

  18. A Bonner Sphere Spectrometer for pulsed fields.

    Science.gov (United States)

    Aza, E; Dinar, N; Manessi, G P; Silari, M

    2016-02-01

    The use of conventional Bonner Sphere Spectrometers (BSS) in pulsed neutron fields (PNF) is limited by the fact that proportional counters, usually employed as the thermal neutron detectors, suffer from dead time losses and show severe underestimation of the neutron interaction rate, which leads to strong distortion of the calculated spectrum. In order to avoid these limitations, an innovative BSS, called BSS-LUPIN, has been developed for measuring in PNF. This paper describes the physical characteristics of the device and its working principle, together with the results of Monte Carlo simulations of its response matrix. The BSS-LUPIN has been tested in the stray neutron field at the CERN Proton Synchrotron, by comparing the spectra obtained with the new device, the conventional CERN BSS and via Monte Carlo simulations.

  19. Influence of the long-chain/short-chain amphiphile ratio on lateral diffusion of PEG-lipid in magnetically aligned lipid bilayers as measured via pulsed-field-gradient NMR.

    Science.gov (United States)

    Soong, Ronald; Macdonald, Peter M

    2005-09-01

    Lateral diffusion measurements of polyethylene glycol(PEG)-lipid incorporated into magnetically aligned lipid bilayers, composed of dimyristoyl phosphatidylcholine (DMPC) plus dihexanoyl phosphatidylcholine (DHPC) plus 1 mol % (relative to DMPC) dimyristoyl phosphatidylethanolamine-n-[methoxy(polyethylene glycol)-2000] (DMPE-PEG 2000), were performed using stimulated-echo pulsed-field-gradient proton ((1)H) nuclear magnetic resonance spectroscopy. The DMPE-PEG 2000 (1 mol %, 35 degrees C) lateral diffusion coefficient D varied directly with the mole fraction of DMPC, X(DMPC) = q/(1+q) where q = DMPC/DHPC molar ratio, decreasing progressively from D = 1.65 x 10(-11) m(2) s(-1) at q approximately 4.7 to D = 0.65 x 10(-11) m(2) s(-1) at q approximately 2.5. Possible sources of this dependence, including orientational disorder, obstruction, and PEG-lipid sequestration, were simulated using, respectively, a diffusion-in-a-cone model, percolation theory, and a two-phase PEG distribution model. Orientational disorder alone was not capable of reproducing the observations, but in combination with either obstruction or PEG-lipid two-phase distribution models did so satisfactorily. A combination of all three models yielded the most reasonable fit to the observed dependence of lateral diffusion on q. These same effects would be expected to influence lateral diffusion of any bilayer-associating species in such systems.

  20. Magnetic Field Generation in Stars

    CERN Document Server

    Ferrario, Lilia; Zrake, Jonathan

    2015-01-01

    Enormous progress has been made on observing stellar magnetism in stars from the main sequence through to compact objects. Recent data have thrown into sharper relief the vexed question of the origin of stellar magnetic fields, which remains one of the main unanswered questions in astrophysics. In this chapter we review recent work in this area of research. In particular, we look at the fossil field hypothesis which links magnetism in compact stars to magnetism in main sequence and pre-main sequence stars and we consider why its feasibility has now been questioned particularly in the context of highly magnetic white dwarfs. We also review the fossil versus dynamo debate in the context of neutron stars and the roles played by key physical processes such as buoyancy, helicity, and superfluid turbulence,in the generation and stability of neutron star fields. Independent information on the internal magnetic field of neutron stars will come from future gravitational wave detections. Thus we maybe at the dawn of a ...

  1. Numerical simulation of the betatron magnetic field using ELCUT software

    Directory of Open Access Journals (Sweden)

    Zatonov Ivan

    2016-01-01

    Full Text Available The article examines the possibility of using software kits to solve multi-physical tasks in betatron engineering. It emphasizes radiation control in aerospace industry using small-size pulse betatron as a source of ionizing radiation. Main characteristics of the betatron magnetic field are calculated using Elcut software kit. Dependence of calculation accuracy on the grid quantity is studied. Focusing properties of the betatron magnetic field are analyzed.

  2. A single-solenoid pulsed-magnet system for single-crystal scattering studies.

    Science.gov (United States)

    Islam, Zahirul; Capatina, Dana; Ruff, Jacob P C; Das, Ritesh K; Trakhtenberg, Emil; Nojiri, Hiroyuki; Narumi, Yasuo; Welp, Ulrich; Canfield, Paul C

    2012-03-01

    We present a pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies with the magnetic field applied on or close to the scattering plane. The apparatus consists of a single large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic fields close to ~30 T with a zero-to-peak-field rise time of ~2.9 ms are generated by discharging a 40 kJ capacitor bank into the magnet coil. The unique characteristic of this instrument is the preservation of maximum scattering angle (~23.6°) on the entrance and exit sides of the magnet bore by virtue of a novel double-funnel insert. This instrument will facilitate x-ray diffraction and spectroscopic studies that are impractical, if not impossible, to perform using split-pair and narrow-opening solenoid magnets. Furthermore, it offers a practical solution for preserving optical access in future higher-field pulsed magnets.

  3. High voltage magnetic pulse generation using capacitor discharge technique

    Directory of Open Access Journals (Sweden)

    M. Rezal

    2014-12-01

    Full Text Available A high voltage magnetic pulse is designed by applying an electrical pulse to the coil. Capacitor banks are developed to generate the pulse current. Switching circuit consisting of Double Pole Double Throw (DPDT switches, thyristor, and triggering circuit is developed and tested. The coil current is measured using a Hall-effect current sensor. The magnetic pulse generated is measured and tabulated in a graph. Simulation using Finite Element Method Magnetics (FEMM is done to compare the results obtained between experiment and simulation. Results show that increasing the capacitance of the capacitor bank will increase the output voltage. This technology can be applied to areas such as medical equipment, measurement instrument, and military equipment.

  4. Micromagnetic simulation of electric-field-assisted magnetization switching in perpendicular magnetic tunnel junction

    Directory of Open Access Journals (Sweden)

    Chikako Yoshida

    2017-05-01

    Full Text Available The feasibility of a voltage assisted unipolar switching in perpendicular magnetic tunnel junction (MTJ has been studied using a micromagnetic simulation. Assuming a linear modulation of anisotropy field with voltage, both parallel (P to anti-parallel (AP and AP to P switchings were observed by application of unipolar voltage pulse without external magnetic field assistance. In latter case, the final P state can only be achieved with an ultrashort voltage pulse which vanishes before spin transfer torque (STT becomes dominant to restore the initial AP state. In addition, it was found that the larger change in anisotropy field is required for the MTJ with smaller diameter.

  5. Micromagnetic simulation of electric-field-assisted magnetization switching in perpendicular magnetic tunnel junction

    Science.gov (United States)

    Yoshida, Chikako; Noshiro, Hideyuki; Yamazaki, Yuichi; Sugii, Toshihiro; Tanaka, Tomohiro; Furuya, Atsushi; Uehara, Yuji

    2017-05-01

    The feasibility of a voltage assisted unipolar switching in perpendicular magnetic tunnel junction (MTJ) has been studied using a micromagnetic simulation. Assuming a linear modulation of anisotropy field with voltage, both parallel (P) to anti-parallel (AP) and AP to P switchings were observed by application of unipolar voltage pulse without external magnetic field assistance. In latter case, the final P state can only be achieved with an ultrashort voltage pulse which vanishes before spin transfer torque (STT) becomes dominant to restore the initial AP state. In addition, it was found that the larger change in anisotropy field is required for the MTJ with smaller diameter.

  6. Indoor localization using magnetic fields

    Science.gov (United States)

    Pathapati Subbu, Kalyan Sasidhar

    Indoor localization consists of locating oneself inside new buildings. GPS does not work indoors due to multipath reflection and signal blockage. WiFi based systems assume ubiquitous availability and infrastructure based systems require expensive installations, hence making indoor localization an open problem. This dissertation consists of solving the problem of indoor localization by thoroughly exploiting the indoor ambient magnetic fields comprising mainly of disturbances termed as anomalies in the Earth's magnetic field caused by pillars, doors and elevators in hallways which are ferromagnetic in nature. By observing uniqueness in magnetic signatures collected from different campus buildings, the work presents the identification of landmarks and guideposts from these signatures and further develops magnetic maps of buildings - all of which can be used to locate and navigate people indoors. To understand the reason behind these anomalies, first a comparison between the measured and model generated Earth's magnetic field is made, verifying the presence of a constant field without any disturbances. Then by modeling the magnetic field behavior of different pillars such as steel reinforced concrete, solid steel, and other structures like doors and elevators, the interaction of the Earth's field with the ferromagnetic fields is described thereby explaining the causes of the uniqueness in the signatures that comprise these disturbances. Next, by employing the dynamic time warping algorithm to account for time differences in signatures obtained from users walking at different speeds, an indoor localization application capable of classifying locations using the magnetic signatures is developed solely on the smart phone. The application required users to walk short distances of 3-6 m anywhere in hallway to be located with accuracies of 80-99%. The classification framework was further validated with over 90% accuracies using model generated magnetic signatures representing

  7. Magnetic Fields in Spiral Galaxies

    CERN Document Server

    Beck, Rainer

    2015-01-01

    Radio synchrotron emission is a powerful tool to study the strength and structure of magnetic fields in galaxies. Unpolarized synchrotron emission traces isotropic turbulent fields which are strongest in spiral arms and bars (20-30\\mu G) and in central starburst regions (50-100\\mu G). Such fields are dynamically important; they affect gas flows and drive gas inflows in central regions. Polarized emission traces ordered fields, which can be regular or anisotropic turbulent, where the latter originates from isotropic turbulent fields by the action of compression or shear. The strongest ordered fields (10-15\\mu G) are generally found in interarm regions. In galaxies with strong density waves, ordered fields are also observed at the inner edges of spiral arms. Ordered fields with spiral patterns exist in grand-design, barred and flocculent galaxies, and in central regions. Ordered fields in interacting galaxies have asymmetric distributions and are a tracer of past interactions between galaxies or with the interg...

  8. Magnetic field of the Earth

    Science.gov (United States)

    Popov, Aleksey

    2013-04-01

    The magnetic field of the Earth has global meaning for a life on the Earth. The world geophysical science explains: - occurrence of a magnetic field of the Earth it is transformation of kinetic energy of movements of the fused iron in the liquid core of Earth - into the magnetic energy; - the warming up of a kernel of the Earth occurs due to radioactive disintegration of elements, with excretion of thermal energy. The world science does not define the reasons: - drift of a magnetic dipole on 0,2 a year to the West; - drift of lithospheric slabs and continents. The author offers: an alternative variant existing in a world science the theories "Geodynamo" - it is the theory « the Magnetic field of the Earth », created on the basis of physical laws. Education of a magnetic field of the Earth occurs at moving the electric charge located in a liquid kernel, at rotation of the Earth. At calculation of a magnetic field is used law the Bio Savara for a ring electric current: dB = . Magnetic induction in a kernel of the Earth: B = 2,58 Gs. According to the law of electromagnetic induction the Faradey, rotation of a iron kernel of the Earth in magnetic field causes occurrence of an electric field Emf which moves electrons from the center of a kernel towards the mantle. So of arise the radial electric currents. The magnetic field amplifies the iron of mantle and a kernel of the Earth. As a result of action of a radial electric field the electrons will flow from the center of a kernel in a layer of an electric charge. The central part of a kernel represents the field with a positive electric charge, which creates inverse magnetic field Binv and Emfinv When ?mfinv = ?mf ; ?inv = B, there will be an inversion a magnetic field of the Earth. It is a fact: drift of a magnetic dipole of the Earth in the western direction approximately 0,2 longitude, into a year. Radial electric currents a actions with the basic magnetic field of a Earth - it turn a kernel. It coincides with laws

  9. Development of a long pulse plasma gun discharge for magnetic turbulence studies

    Science.gov (United States)

    Schaffner, David

    2016-10-01

    A long pulse ( 300 μs) plasma gun discharge is in development at the Bryn Mawr College Plasma Laboratory for the production of sustained magnetized plasma injection for magnetohydrodynamic (MHD) turbulence studies. An array of eight 0.5mF parallel capacitors are used to create a pulse-forming-network (PFN) with a plateaued current output of 50kA for at least 200 of the 300 μs pulse. A 24cm inner diameter plasma gun provides stuffing flux fields at the stuffing threshold in order to allow for the continuous injection of magnetic helicity. Plasma is injected into a 24cm diameter flux-conserving aluminum chamber with a high density port array for fine spatial resolution diagnostic access. Fluctuations of magnetic field and saturation current are measured using pickup probes and Langmuir probes respectively.

  10. Radiation from high-intensity ultrashort-laser-pulse and gas-jet magnetized plasma interaction.

    Science.gov (United States)

    Dorranian, Davoud; Starodubtsev, Mikhail; Kawakami, Hiromichi; Ito, Hiroaki; Yugami, Noboru; Nishida, Yasushi

    2003-08-01

    Using a gas-jet flow, via the interaction between an ultrashort high-intensity laser pulse and plasma in the presence of a perpendicular external dc magnetic field, the short pulse radiation from a magnetized plasma wakefield has been observed. Different nozzles are used in order to generate different densities and gas profiles. The neutral density of the gas-jet flow measured with a Mach-Zehnder interferometer is found to be proportional to back pressure of the gas jet in the range of 1 to 8 atm. Strength of the applied dc magnetic field varies from 0 to 8 kG at the interaction region. The frequency of the emitted radiation with the pulse width of 200 ps (detection limit) is in the millimeter wave range. Polarization and spatial distributions of the experimental data are measured to be in good agreement with the theory based on the V(p)xB radiation scheme, where V(p) is the phase velocity of the electron plasma wave and B is the steady magnetic field intensity. Characteristics of the radiation are extensively studied as a function of plasma density and magnetic field strength. These experiments should contribute to the development of a new kind of millimeter wavelength radiation source that is tunable in frequency, pulse duration, and intensity.

  11. Pulsed electric field assisted assembly of polyaniline

    Science.gov (United States)

    Kumar, Arun; Kazmer, David O.; Barry, Carol M. F.; Mead, Joey L.

    2012-08-01

    Assembling conducting polyaniline (PANi) on pre-patterned nano-structures by a high rate, commercially viable route offers an opportunity for manufacturing devices with nanoscale features. In this work we report for the first time the use of pulsed electric field to assist electrophoresis for the assembly of conducting polyaniline on gold nanowire interdigitated templates. This technique offers dynamic control over heat build-up, which has been a main drawback in the DC electrophoresis and AC dielectrophoresis as well as the main cause of nanowire template damage. The use of this technique allowed higher voltages to be applied, resulting in shorter assembly times (e.g., 17.4 s, assembly resolution of 100 nm). Moreover, the area coverage increases with the increase in number of pulses. A similar trend was observed with the deposition height and the increase in deposition height followed a linear trend with a correlation coefficient of 0.95. When the experimental mass deposited was compared with Hamaker’s theoretical model, the two were found to be very close. The pre-patterned templates with PANi deposition were subsequently used to transfer the nanoscale assembled PANi from the rigid templates to thermoplastic polyurethane using the thermoforming process.

  12. 脉冲磁场在旋流-静态微泡浮选柱中的应用%Application of the Pulsed Magnetic Field in the Cyclone-static Microbubble Flotation Column

    Institute of Scientific and Technical Information of China (English)

    李超; 曹亦俊; 杨兴满; 牛国鹏; 刘永华

    2011-01-01

    为降低某磁铁矿选矿厂的浮选尾矿品位,进行了新型磁浮选脱硅试验研究.结果表明,相比常规旋流-静态微泡浮选柱1次粗选、2次扫选反浮选工艺流程,浮选柱柱体附加脉冲磁场后采用1次粗选、1次扫选工艺流程,在入浮原矿性质和精矿品位基本相同的情况下,浮选时间缩短了30%,尾矿品位降低了6.35个百分点,回收率提高0.95个百分点.磁浮选方法在磁铁矿反浮选中的应用,为我国磁铁矿分选开辟一条新的途径.%In order to reduce the flotation tailings grade of a dressing plant of magnetite, experimental researches on the new magnetic flotation with silicon removal were carried out. The results showed that comparing with the conventional inverse flotation process of one-roughing and two-scavenging with cyclone-static microbubble flotation column, the process of one-roughing and one-scavenging after the flotation column was added with an additional pulsed magnetic field shortened the flotation time of 30%, reduced the tailings grade by 6.35 percent, and increased the recovery by 0.95 percent under the similar circumstances of raw ore' s nature and concentrate grade before the flotation. The application of magnetic flotation method in reverse flotation of magnetite opens up a new approach for the separation of magnetite in China.

  13. Optimization of the output power of a pulsed gas laser by using magnetic pulse compression

    Science.gov (United States)

    Louhibi, D.; Ghobrini, Mourad; Bourai, K.

    1999-12-01

    In pulsed gas lasers, the excitation of the active medium is produced through the discharge of a storage capacitor. Performances of these lasers were essentially linked to the type of switch used and also to its mode of operation. Thyratrons are the most common switches. Nevertheless, their technological limitations do not allow a high repetition rate, necessary for optimization of the output power of this type of laser. These limitations can be surpassed by combining the thyratron to a one stage of a magnetic pulse compression circuit. The mpc driver can improve the laser excitation pulse rise time and increase the repetition rate, increasing the laser output power of pulsed gas laser such as; nitrogen, excimer and copper vapor lasers. We have proposed in this paper a new configuration of magnetic pulse compression, the magnetic switch is place in our case in the charge circuit, and while in the typical utilization of magnetic pulse compression, it is placed in the discharge circuit. In this paper, we are more particularly interested in the design and the modeling of a saturate inductance that represents the magnetic switch in the proposed configuration of a thyratron - mpc circuit combination.

  14. Magnetic fields of neutron stars

    CERN Document Server

    Reisenegger, Andreas

    2013-01-01

    Neutron stars contain the strongest magnetic fields known in the Universe. In this paper, I discuss briefly how these magnetic fields are inferred from observations, as well as the evidence for their time-evolution. I show how these extremely strong fields are actually weak in terms of their effects on the stellar structure, as is also the case for magnetic stars on the upper main sequence and magnetic white dwarfs, which have similar total magnetic fluxes. I propose a scenario in which a stable hydromagnetic equilibrium (containing a poloidal and a toroidal field component) is established soon after the birth of the neutron star, aided by the strong compositional stratification of neutron star matter, and this state is slowly eroded by non-ideal magnetohydrodynamic processes such as beta decays and ambipolar diffusion in the core of the star and Hall drift and breaking of the solid in its crust. Over sufficiently long time scales, the fluid in the neutron star core will behave as if it were barotropic, becau...

  15. Magnetic fields during galaxy mergers

    CERN Document Server

    Rodenbeck, Kai

    2016-01-01

    Galaxy mergers are expected to play a central role for the evolution of galaxies, and may have a strong impact on their magnetic fields. We present the first grid-based 3D magneto-hydrodynamical simulations investigating the evolution of magnetic fields during merger events. For this purpose, we employ a simplified model considering the merger event of magnetized gaseous disks in the absence of stellar feedback and without a stellar or dark matter component. We show that our model naturally leads to the production of two peaks in the evolution of the average magnetic field strength within 5 kpc, within 25 kpc and on scales in between 5 and 25 kpc. The latter is consistent with the peak in the magnetic field strength reported by Drzazga et al. (2011) in a merger sequence of observed galaxies. We show that the peak on the galactic scale and in the outer regions is likely due to geometrical effects, as the core of one galaxy enters the outskirts of the other one. In addition, there is a physical enhancement of t...

  16. Dynamic pulsed-field-gradient NMR

    CERN Document Server

    Sørland, Geir Humborstad

    2014-01-01

    Dealing with the basics, theory and applications of dynamic pulsed-field-gradient NMR NMR (PFG NMR), this book describes the essential theory behind diffusion in heterogeneous media that can be combined with NMR measurements to extract important information of the system being investigated. This information could be the surface to volume ratio, droplet size distribution in emulsions, brine profiles, fat content in food stuff, permeability/connectivity in porous materials and medical applications currently being developed. Besides theory and applications it will provide the readers with background knowledge on the experimental set-ups, and most important, deal with the pitfalls that are numerously present in work with PFG-NMR. How to analyze the NMR data and some important basic knowledge on the hardware will be explained, too.

  17. Zero magnetic field type magnetic field sensor. Reijikaigata jikai sensor

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, T.; Ueda, R. (Kyushu Institute of Technology, Fukuoka (Japan))

    1990-11-20

    It is shown in this paper that a new type of sensor with excellent characteristics can be made by demagnetizing the sensor core toward a zero field state and then detecting an unknown field to be detected by the demagnetizing current. The core operates equivalently in a zero magnetic field so that the detection sensitivity is determined by the coil constant including the number of turns of the solenoid for demagnetization required to offset the field to be detected. Therefore the detection sensitivity does not depend on its configuration and magnetization characteristics and does not depend on the temperature. It is thereby considered that these characteristics can largely reduce such problems at present as the aging deterioration of magnetic materials or the quality control accompanied by manufacturing. In addition, the following points have been clarified: (1) The upper limit of the detectable range does not exist in principle. (2) The accuracy of the detection is 0.02% to the full scale 20kA/m. (3) The magnetization property required to the core used as a sensor is that it has a rectangular B-H loop which is as sharp as possible. 14 refs., 13 figs., 2 tabs.

  18. Increasing the magnetic helicity content of a plasma by pulsing a magnetized source.

    Science.gov (United States)

    Woodruff, S; Stallard, B W; McLean, H S; Hooper, E B; Bulmer, R; Cohen, B I; Hill, D N; Holcomb, C T; Moller, J; Wood, R D

    2004-11-12

    By operating a magnetized coaxial gun in a pulsed mode it is possible to produce large voltage pulses of duration approximately 500 mus while reaching a few kV, giving a discrete input of helicity into a spheromak. In the sustained spheromak physics experiment (SSPX), it is observed that pulsing serves to nearly double the stored magnetic energy and double the temperature. We discuss these results by comparison with 3D MHD simulations of the same phenomenon.

  19. Deficiencies of active electronic radiation protection dosimeters in pulsed fields.

    Science.gov (United States)

    Ankerhold, U; Hupe, O; Ambrosi, P

    2009-07-01

    Nowadays nearly all radiation fields used for X-ray diagnostics are pulsed. These fields are characterised by a high dose rate during the pulse and a short pulse duration in the range of a few milliseconds. The use of active electronic dosimeters has increased in the past few years, but these types of dosimeters might possibly not measure reliably in pulsed radiation fields. Not only personal dosimeters but also area dosimeters that are used mainly for dose rate measurements are concerned. These cannot be substituted by using passive dosimeter types. The characteristics of active electronic dosimeters determined in a continuous radiation field cannot be transferred to those in pulsed fields. Some provisional measurements with typical electronic dosimeters in pulsed radiation fields are presented to reveal this basic problem.

  20. Magnetically insulated electron flows in pulsed power systems

    Science.gov (United States)

    Lawconnell, Robert I.

    1989-08-01

    Magnetic insulation is crucial in the operation of large pulsed power systems. Particular attention will be paid to describing magnetic insulation in realistic pulsed power systems. A theoretical model is developed that allows the production of self consistent magnetically insulated laminar flows in perturbed cylindrical systems given only the electron density profile. The theory is checked and justified by detailed comparisons with results from a 2-dimensional electromagnetic code, MASK. The procedure followed in the theoretical development is to use the relativistic Vlasov equation, Ampere's law and Gauss' law, to obtain a relation between the density profile and the velocity profile for insulated flows. Given the density profile and the corresponding derived velocity profile, a self consistent flow solution is obtained by means of Maxwell's equations. It is checked by taking a special case (corresponding to no perturbations) which results in the well known Brillouin flow theory. Emphasis is placed on determining the magnetic insulation threshold of a pulsed power system employing a plasma erosion opening switch. The procedure employed in the computational study is to vary critical aspects of the pulsed power system and then note whether magnetic insulation breaks down. The point at which magnetic insulation breaks down (as a function of geometry, load impedance, and applied voltage) is the magnetic insulation threshold for the system.

  1. Magnetic Field Effects on Relaxation Parameters of The Hexamethylenetetramine (HMT)

    Science.gov (United States)

    Dogan, Nurcan

    2013-03-01

    The use of low magnetic field is one of the method for improvement of the signal to noise ratio (SNR) of detection of the chemical compounds by nuclear quadrupole resonance (NQR). We investigated the FID phenomenon of nuclear quadrupole resonance (NQR) from hexamethylenetetramine (HMT), C6H12N4, under magnetic field. The influence of the low magnetic field (up to 30 mT) was investigated for the detection of the pulse NQR signal for HMT We detected the pure NQR FID signal of HMT with a short pulse interval. The intensity of the FID signal changed with applied magnetic field. The application of the low magnetic field produces the splitting and brodening of the NQR line. We observed T1, T2 and T2*. HMT has a long T2*(near 1.5ms). This one represents the suitable sample for investigation of the influence of low magnetic field for NQR detection. The application of the low magnetic field produces the splitting and brodening of the NQR line.

  2. Primordial Magnetic Fields and Causality

    CERN Document Server

    Durrer, R; Durrer, Ruth; Caprini, Chiara

    2003-01-01

    In this letter we discuss the implications of causality on a primordial magnetic field. We show that the residual field on large scales is much stronger suppressed than usually assumed and that a helical component is even suppressed even more than the parity even part. We show that due to this strong suppression, even maximal primordial fields generated at the electroweak phase transition can just marginally seed the fields in galaxies and clusters, but they cannot leave any detectable imprint on the cosmic microwave background.

  3. Stray Field Reduction in ALS Eddy Current Septum Magnets

    CERN Document Server

    Shuman, Derek; Prestemon, Soren; Schlüter, Ross D; Steier, Christoph; Stover, Gregory D

    2005-01-01

    Stray field from an eddy current septum magnet adversely affects the circulating beam and can be reduced using several techniques. The stray field time history typically has a fast rise section followed by a long exponential decay section when pulsed with a half sine drive current. Changing the drive current pulse to a full sine has the effect of both reducing peak stray field magnitude by ~3x, and producing a quick decay from this peak to a lower field level which then has a similar long decay time constant as that from the half sine only drive current pulse. A method for tuning the second half sine (reverse) drive current pulse to eliminate the long exponential decay section is given.

  4. Analysis on Eddy Current Thermal Effect of the Rigid Conductive Thin Plate Under Multi-pulse Magnetic Field%多脉冲磁场下刚性导电薄板涡电流热效应分析

    Institute of Scientific and Technical Information of China (English)

    张建平; 戴咏夏

    2009-01-01

    针对处于多脉冲磁场下感应加热系统装置中的刚性导电薄板,基于麦克斯韦电磁场方程组及导热微分方程,建立了涡电流场和温度场的理论模型.对涡电流初边值问题及由涡电流热效应引起的温度场定解问题的空间部分采用有限元法,时间部分采用Crank-Nicolson法,给出了计算程序的求解步骤,并进行了定量模拟.仿真结果表明,脉冲次数使得构件的涡电流和温度逐步增加,随后其大小趋于稳定的值,而后来的周期性脉冲只不过是保持这个恒定值不衰减.该结论为电磁感应加热设备的革新改造提供了有效的技术参考.%Based on Maxwell's equations and the thermal conduction differential equation, a theoretical model for rigid conductive thin plate of induction-heating system under multi-pulse magnetic field was established with eddy current field and temperature field included. The numerical steps of algorithm routine along with quantitative simulation were given by adopting the finite element method for the spatial part in the eddy current initial boundary-value problem and the determining-solution problem of temperature field arisen from eddy current thermal effect, and the Crank-Nicolson methods for the time part. The simulation results indicate that the eddy current and the temperature increase with the pulse times, and tend to stable values,thereafter seasonal impulses just only to keep this constant value not diminishing. It provides effective technical reference for innovation of the electromagnetic induction-heating equipment.

  5. Magnetization and microstructure dynamics in Fe/MnAs/GaAs(001): Fe magnetization reversal by a femtosecond laser pulse.

    Science.gov (United States)

    Spezzani, C; Ferrari, E; Allaria, E; Vidal, F; Ciavardini, A; Delaunay, R; Capotondi, F; Pedersoli, E; Coreno, M; Svetina, C; Raimondi, L; Zangrando, M; Ivanov, R; Nikolov, I; Demidovich, A; Danailov, M B; Popescu, H; Eddrief, M; De Ninno, G; Kiskinova, M; Sacchi, M

    2014-12-12

    Thin film magnetization reversal without applying external fields is an attractive perspective for applications in sensors and devices. One way to accomplish it is by fine-tuning the microstructure of a magnetic substrate via temperature control, as in the case of a thin Fe layer deposited on a MnAs/GaAs(001) template. This work reports a time-resolved resonant scattering study exploring the magnetic and structural properties of the Fe/MnAs system, using a 100 fs optical laser pulse to trigger local temperature variations and a 100 fs x-ray free-electron laser pulse to probe the induced magnetic and structural dynamics. The experiment provides direct evidence that a single optical laser pulse can reverse the Fe magnetization locally. It reveals that the time scale of the magnetization reversal is slower than that of the MnAs structural transformations triggered by the optical pulse, which take place after a few picoseconds already.

  6. Magnetic fields around black holes

    Science.gov (United States)

    Garofalo, David A. G.

    Active Galactic Nuclei are the most powerful long-lived objects in the universe. They are thought to harbor supermassive black holes that range from 1 million solar masses to 1000 times that value and possibly greater. Theory and observation are converging on a model for these objects that involves the conversion of gravitational potential energy of accreting gas to radiation as well as Poynting flux produced by the interaction of the rotating spacetime and the electromagnetic fields originating in the ionized accretion flow. The presence of black holes in astrophysics is taking center stage, with the output from AGN in various forms such as winds and jets influencing the formation and evolution of the host galaxy. This dissertation addresses some of the basic unanswered questions that plague our current understanding of how rotating black holes interact with their surrounding magnetized accretion disks to produce the enormous observed energy. Two magnetic configurations are examined. The first involves magnetic fields connecting the black hole with the inner accretion disk and the other involves large scale magnetic fields threading the disk and the hole. We study the effects of the former type by establishing the consequences that magnetic torques between the black hole and the inner accretion disk have on the energy dissipation profile. We attempt a plausible explanation to the observed "Deep Minimum" state in the Seyfert galaxy MCG-6- 30-15. For the latter type of magnetic geometry, we study the effects of the strength of the magnetic field threading the black hole within the context of the cherished Blandford & Znajek mechanism for black hole spin energy extraction. We begin by addressing the problem in the non-relativistic regime where we find that the black hole-threading magnetic field is stronger for greater disk thickness, larger magnetic Prandtl number, and for a larger accretion disk. We then study the problem in full relativity where we show that our

  7. 脉冲磁场治疗骨质疏松磁场照射区与非照射区骨密度变化%The bone mineral density changes of magnetic field irradiation area bones and non radiation area bones after pulse magnetic field treatment of steoporosis

    Institute of Scientific and Technical Information of China (English)

    翟贵生; 杨莉; 姜文学; 陈先农; 屈承端

    2013-01-01

    Objective to explore the correlation of bone mineral density changes of magnetic field irradiation area bones and non radiation area bones After pulse magnetic field treatment of osteoporosis.Methods 10 patients with postmenopausal osteoporosis,age 48 ~ 76,an average of 56.8.The TY-PEMF treatment osteoporosis therapy apparatus was used,magnetic fields generating from Chain shape therapeutic devices irradiate human body spine and femur,40 min per treatment,10 times for a period of treatment,a total of 3 period of treatment,in two months to be completed.LUNAR dual-energy X-ray absorptiometry bone mineral density instrument and The MetriscanTM bone mineral density instrument were separately applied to measurement bone mineral density of L2-4 bone and 2,3,4 finger bone before and after treatment 8 months.Results The L2-4 bone density increased by 5.37% on average,phalanx bone density rose by an average of 5.23%.Conclusion The pulse magnetic field treatment of osteoporosis,bone mineral density of irradiation area bones has improved significantly,bone mineral density of non irradiation area bones have similar improvement.%目的 探索脉冲磁场治疗骨质疏松磁场照射区和非照射区骨密度的变化及相关性.方法 选择绝经后骨质疏松患者10例,年龄48 ~ 76岁,平均56.8岁.采用TY-PEMF骨质疏松治疗仪治疗,链状形治疗器产生的磁场照射人体中心部位脊柱和股骨,每次治疗40 min,10次为一疗程,总共3个疗程,两个月完成.分别应用LUNAR双能X线吸收骨密度仪和The MetriscanTM骨密度仪测量治疗前及治疗后第8个月L2-4骨密度和2、3、4指骨密度均值.结果 L2-4骨密度平均增加5.37%,指骨骨密度均值平均增加5.23%.结论 脉冲磁场治疗骨质疏松,磁场照射部位腰椎骨密度有明显改善,非照射区的指骨密度也有相似的改善.

  8. Chiral transition with magnetic fields

    CERN Document Server

    Ayala, Alejandro; Mizher, Ana Julia; Rojas, Juan Cristobal; Villavicencio, Cristian

    2014-01-01

    We study the nature of the chiral transition for an effective theory with spontaneous breaking of symmetry, where charged bosons and fermions are subject to the effects of a constant external magnetic field. The problem is studied in terms of the relative intensity of the magnetic field with respect to the mass and the temperature. When the former is the smallest of the scales, we present a suitable method to obtain magnetic and thermal corrections up to ring order at high temperature. By these means, we solve the problem of the instability in the boson sector for these theories, where the squared masses, taken as functions of the order parameter, can vanish and even become negative. The solution is found by considering the screening properties of the plasma, encoded in the resummation of the ring diagrams at high temperature. We also study the case where the magnetic field is the intermediate of the three scales and explore the nature of the chiral transition as we vary the field strength, the coupling const...

  9. Magnetic Fields of Neutron Stars

    Indian Academy of Sciences (India)

    Sushan Konar

    2017-09-01

    This article briefly reviews our current understanding of the evolution of magnetic fields in neutron stars, which basically defines the evolutionary pathways between different observational classes of neutron stars. The emphasis here is on the evolution in binary systems and the newly emergent classes of millisecond pulsars.

  10. Probing High Temperature Superconductors with Magnetometry in Ultrahigh Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lu [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-07-26

    The objective of this research is to investigate the high-field magnetic properties of high temperature superconductors, materials that conduct electricity without loss. A technique known as high-resolution torque magnetometry that was developed to directly measure the magnetization of high temperature superconductors. This technique was implemented using the 65 Tesla pulsed magnetic field facility that is part of the National High Magnetic Field Laboratory at Los Alamos National Laboratory. This research addressed unanswered questions about the interplay between magnetism and superconductivity, determine the electronic structure of high temperature superconductors, and shed light on the mechanism of high temperature superconductivity and on potential applications of these materials in areas such as energy generation and power transmission. Further applications of the technology resolve the novel physical phenomena such as correlated topological insulators, and spin liquid state in quantum magnets.

  11. Manipulation of magnetic carriers for drug delivery using pulsed-current high T {sub c} superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yung [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)]. E-mail: yscha@anl.gov; Chen, Lihua [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824 (United States); Askew, Thomas [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Physics Department, Kalamazoo College, Kalamazoo, MI 49006 (United States); Veal, Boyd [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Hull, John [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)

    2007-04-15

    An innovative method of manipulating magnetic carriers is proposed, and its feasibility for drug delivery and therapy is demonstrated experimentally. The proposed method employs pulsed-field solenoid coils with high-critical- temperature (T {sub c}) superconductor inserts. Pulsed current is used to magnetize and de-magnetize the superconductor insert. The proposed method was demonstrated to be able to (1) move magnetic particles, ranging in size from a few millimeters to 10 {mu}m, with strong enough forces over a substantial distance, (2) hold the particles at a designated position as long as needed, and (3) reverse the processes and retrieve the particles. We further demonstrated that magnetic particles can be manipulated in a stationary environment, in water flow, and in simulated blood (water/glycerol mixture) flow.

  12. Manipulation of magnetic carriers for drug delivery using pulsed-current high Tc superconductors

    Science.gov (United States)

    Cha, Yung; Chen, Lihua; Askew, Thomas; Veal, Boyd; Hull, John

    2007-04-01

    An innovative method of manipulating magnetic carriers is proposed, and its feasibility for drug delivery and therapy is demonstrated experimentally. The proposed method employs pulsed-field solenoid coils with high-critical- temperature ( Tc) superconductor inserts. Pulsed current is used to magnetize and de-magnetize the superconductor insert. The proposed method was demonstrated to be able to (1) move magnetic particles, ranging in size from a few millimeters to 10 μm, with strong enough forces over a substantial distance, (2) hold the particles at a designated position as long as needed, and (3) reverse the processes and retrieve the particles. We further demonstrated that magnetic particles can be manipulated in a stationary environment, in water flow, and in simulated blood (water/glycerol mixture) flow.

  13. Structural and magnetic properties of Gd/Fe multilayers grown by pulsed laser deposition

    DEFF Research Database (Denmark)

    Kant, K. Mohan; Bahl, Christian Robert Haffenden; Pryds, Nini;

    This work investigates structural and magnetic properties of Gd/Fe multilayered thin films grown by pulsed laser deposition onto Si (001) substrates at room temperature. The Fe layer thickness is varied from 70 to 150 nm and its effect on structural and magnetic properties of Gd/Fe multilayers has...... been explored. The samples have a 10 nm Ag capping layer to prevent oxidation during the processing. Two magnetization saturation plateaus were observed in the magnetization vs field isotherm at 290 K, in parallel configuration and these plateau values correspond to that of MFe and MFe + MGd....

  14. Storage of magnetization as singlet order by optimal control designed pulses

    DEFF Research Database (Denmark)

    Laustsen, Christoffer; Bowen, Sean; Vinding, Mads Sloth

    2014-01-01

    . With this aim, optimal control theory was applied to create pulses that for near‐equivalent spins accomplish transfers in and out of the singlet state with maximum efficiency while ensuring robustness toward variations in the nuclear spin system Hamiltonian (chemical shift, J‐couplings, B1 and B magnetic field...

  15. Device for measurement of power and shape of radio frequency pulses in nuclear magnetic resonance

    Science.gov (United States)

    Pfeffer, M.; Řezníček, R.; Křišťan, P.; Štěpánková, H.

    2012-05-01

    A design of an instrument to measure the power and shape of radio frequency (RF) pulses operating in a broad frequency range is described. The device is capable of measuring the pulse power up to 500 W of both CW and extremely short (˜1 μs) RF pulses of arbitrary period. The pulse envelope can be observed on a logarithmic scale on a corresponding instrument output using an inexpensive storage oscilloscope. The instrument consists of a coaxial measurement head, the RF processing circuits and an AD conversion and display unit. The whole device is based on widely available integrated circuits; thus, good reproducibility and adaptability of the design is ensured. Since the construction is intended to be used in particular (but not solely) in nuclear magnetic resonance spectroscopy, we found it useful to provide a demonstration of two typical usage scenarios. Other application fields may comprise magnetic resonance imaging, radar and laser technology, power amplifier testing, etc.

  16. Effects of MHD slow shocks propagating along magnetic flux tubes in a dipole magnetic field

    Directory of Open Access Journals (Sweden)

    N. V. Erkaev

    2002-01-01

    Full Text Available Variations of the plasma pressure in a magnetic flux tube can produce MHD waves evolving into shocks. In the case of a low plasma beta, plasma pressure pulses in the magnetic flux tube generate MHD slow shocks propagating along the tube. For converging magnetic field lines, such as in a dipole magnetic field, the cross section of the magnetic flux tube decreases enormously with increasing magnetic field strength. In such a case, the propagation of MHD waves along magnetic flux tubes is rather different from that in the case of uniform magnetic fields. In this paper, the propagation of MHD slow shocks is studied numerically using the ideal MHD equations in an approximation suitable for a thin magnetic flux tube with a low plasma beta. The results obtained in the numerical study show that the jumps in the plasma parameters at the MHD slow shock increase greatly while the shock is propagating in the narrowing magnetic flux tube. The results are applied to the case of the interaction between Jupiter and its satellite Io, the latter being considered as a source of plasma pressure pulses.

  17. Magnetic fields in spiral galaxies

    Science.gov (United States)

    Krause, Marita

    2015-03-01

    The magnetic field structure in edge-on galaxies observed so far shows a plane-parallel magnetic field component in the disk of the galaxy and an X-shaped field in its halo. The plane-parallel field is thought to be the projected axisymmetric (ASS) disk field as observed in face-on galaxies. Some galaxies addionionally exhibit strong vertical magnetic fields in the halo right above and below the central region of the disk. The mean-field dynamo theory in the disk cannot explain these observed fields without the action of a wind, which also probably plays an important role to keep the vertical scale heights constant in galaxies of different Hubble types and star formation activities, as has been observed in the radio continuum: At λ6 cm the vertical scale heights of the thin disk and the thick disk/halo in a sample of five edge-on galaxies are similar with a mean value of 300 +/- 50 pc for the thin disk and 1.8 +/- 0.2 kpc for the thick disk (a table and references are given in Krause 2011) with our sample including the brightest halo observed so far, NGC 253, with strong star formation, as well as one of the weakest halos, NGC 4565, with weak star formation. If synchrotron emission is the dominant loss process of the relativistic electrons the outer shape of the radio emission should be dumbbell-like as has been observed in several edge-on galaxies like e.g. NGC 253 (Heesen et al. 2009) and NGC 4565. As the synchrotron lifetime t syn at a single frequency is proportional to the total magnetic field strength B t -1.5, a cosmic ray bulk speed (velocity of a galactic wind) can be defined as v CR = h CR /t syn = 2 h z /t syn , where h CR and h z are the scale heights of the cosmic rays and the observed radio emission at this freqnency. Similar observed radio scale heights imply a self regulation mechanism between the galactic wind velocity, the total magnetic field strength and the star formation rate SFR in the disk: v CR ~ B t 1.5 ~ SFR ~ 0.5 (Niklas & Beck 1997).

  18. Primordial Magnetic Fields that Last?

    CERN Document Server

    Carroll, S M; Carroll, Sean M.; Field, George B.

    1998-01-01

    The magnetic fields we observe in galaxies today may have their origins in the very early universe. While a number of mechanisms have been proposed which lead to an appreciable field amplitude at early times, the subsequent evolution of the field is of crucial importance, especially whether the correlation length of the field can grow as large as the size of a protogalaxy. This talk is a report on work in progress, in which we consider the fate of one specific primordial field scenario, driven by pseudoscalar effects near the electroweak phase transition. We argue that such a scenario has a number of attractive features, although it is still uncertain whether a field of appropriate size can survive until late times.

  19. Magnetic Properties of Erbium Gallium Gallate under High Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    Zhang Xijuan; Cheng Haiying; Yang Cuihong; Wang Wei

    2004-01-01

    A theoretical investigation on the magnetic properties of rare-earth Er3+ in Er3 Ga5 O12 was reported. The average magnetic moments(M) for applied magnetic field H parallel to the [001 ], [ 100], [ 110], [ 111 ] direction was studied based on the quantum theory. Temperature dependence of the magnetic properties is analyzed for H applied parallel to the [ 100] and [ 111 ] crystallographic directions. The magnetization decreases with increasing temperature,showing good agreement with thermal effect. A strong anisotropy of the magnetization is found under high magnetic field, but when the magnetic field is small, M and H are proportional.

  20. Bag model for DNA migration during pulsed-field electrophoresis.

    OpenAIRE

    Chu, G

    1991-01-01

    A model for pulsed-field electrophoresis was developed by picturing large DNA as a deformable "bag" that (i) moves with limiting mobility in a continuous electric field, (ii) adopts an orientation aligned with the field direction, and (iii) reorients after a change in field direction in a size-dependent manner. The model correctly predicted the resolution of large DNA in a pulsed field including the surprising phenomena of mobility inversion, lateral band spreading, and improved resolution fo...

  1. Magnetic Field Gradient Waveform Monitoring for Magnetic Resonance

    Science.gov (United States)

    Han, Hui

    Linear magnetic field gradients have played a central role in Magnetic Resonance Imaging (MRI) since Fourier Transform MRI was proposed three decades ago. Their primary function is to encode spatial information into MR signals. Magnetic field gradients are also used to sensitize the image contrast to coherent and/or incoherent motion, to selectively enhance an MR signal, and to minimize image artifacts. Modern MR imaging techniques increasingly rely on the implementation of complex gradient waveforms for the manipulation of spin dynamics. However, gradient system infidelities caused by eddy currents, gradient amplifier imperfections and group delays, often result in image artifacts and other errors (e.g., phase and intensity errors). This remains a critical problem for a wide range of MRI techniques on modern commercial systems, but is of particular concern for advanced MRI pulse sequences. Measuring the real magnetic field gradients, i.e., characterizing eddy currents, is critical to addressing and remedying this problem. Gradient measurement and eddy current calibration are therefore a general topic of importance to the science of MRI. The Magnetic Field Gradient Monitor (MFGM) idea was proposed and developed specifically to meet these challenges. The MFGM method is the heart of this thesis. MFGM methods permit a variety of magnetic field gradient problems to be investigated and systematically remedied. Eddy current effects associated with MR compatible metallic pressure vessels were analyzed, simulated, measured and corrected. The appropriate correction of eddy currents may enable most MR/MRI applications with metallic pressure vessels. Quantitative imaging (1D/2D) with model pressure vessels was successfully achieved by combining image reconstruction with MFGM determined gradient waveform behaviour. Other categories of MR applications with metallic vessels, including diffusion measurement and spin echo SPI T2 mapping, cannot be realized solely by MFGM guided

  2. Modeling and analysis of magnetic dipoles in weak magnetic field

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The magnetic leakage field distribution resulting from linear defects of a tube sample in the geomagnetic field is modeled according to the magnetic dipole theory.The formula to compute the normal component of the weak magnetic field is deduced based on the spatial distribution of the magnetic dipole.The shape and characteristics of the zero line (an important criterion for magnetic memory testing) of the normal field is analyzed under different longitudinal magnetizations.Results show that the characteristics of the zero line should be considered when the metal magnetic memory testing method is used to find and locate the defect.

  3. Improved convection compensating pulsed field gradient spin-echo and stimulated-echo methods.

    Science.gov (United States)

    Sørland, G H; Seland, J G; Krane, J; Anthonsen, H W

    2000-02-01

    The need for convection compensating methods in NMR has been manifested through an increasing number of publications related to the subject over the past few years (J. Magn. Reson. 125, 372 (1997); 132, 13 (1998); 131, 126 (1998); 118, 50 (1996); 133, 379 (1998)). When performing measurements at elevated temperature, small convection currents may give rise to erroneous values of the diffusion coefficient. In work with high resolution NMR spectroscopy, the application of magnetic field gradients also introduces an eddy-current magnetic field which may result in errors in phase and baseline in the FFT-spectra. The eddy current field has been greatly suppressed by the application of bipolar magnetic field gradients. However, when introducing bipolar magnetic field gradients, the pulse sequence is lengthened significantly. This has recently been pointed out as a major drawback because of the loss of coherence and of NMR-signal due to transverse relaxation processes. Here we present modified convection compensating pulsed field gradient double spin echo and double stimulated echo sequences which suppress the eddy-current magnetic field without increasing the duration of the pulse sequences.

  4. Galactic and intergalactic magnetic fields

    CERN Document Server

    Klein, Ulrich

    2014-01-01

    This course-tested textbook conveys the fundamentals of magnetic fields and relativistic plasma in diffuse cosmic media, with a primary focus on phenomena that have been observed at different wavelengths. Theoretical concepts are addressed wherever necessary, with derivations presented in sufficient detail to be generally accessible.In the first few chapters the authors present an introduction to various astrophysical phenomena related to cosmic magnetism, with scales ranging from molecular clouds in star-forming regions and supernova remnants in the Milky Way, to clusters of galaxies. Later c

  5. Error field and magnetic diagnostic modeling for W7-X

    Energy Technology Data Exchange (ETDEWEB)

    Lazerson, Sam A. [PPPL; Gates, David A. [PPPL; NEILSON, GEORGE H. [PPPL; OTTE, M.; Bozhenkov, S.; Pedersen, T. S.; GEIGER, J.; LORE, J.

    2014-07-01

    The prediction, detection, and compensation of error fields for the W7-X device will play a key role in achieving a high beta (Β = 5%), steady state (30 minute pulse) operating regime utilizing the island divertor system [1]. Additionally, detection and control of the equilibrium magnetic structure in the scrape-off layer will be necessary in the long-pulse campaign as bootstrapcurrent evolution may result in poor edge magnetic structure [2]. An SVD analysis of the magnetic diagnostics set indicates an ability to measure the toroidal current and stored energy, while profile variations go undetected in the magnetic diagnostics. An additional set of magnetic diagnostics is proposed which improves the ability to constrain the equilibrium current and pressure profiles. However, even with the ability to accurately measure equilibrium parameters, the presence of error fields can modify both the plasma response and diverter magnetic field structures in unfavorable ways. Vacuum flux surface mapping experiments allow for direct measurement of these modifications to magnetic structure. The ability to conduct such an experiment is a unique feature of stellarators. The trim coils may then be used to forward model the effect of an applied n = 1 error field. This allows the determination of lower limits for the detection of error field amplitude and phase using flux surface mapping. *Research supported by the U.S. DOE under Contract No. DE-AC02-09CH11466 with Princeton University.

  6. The new installation at the Nijmegen High Field Magnet Laboratory

    NARCIS (Netherlands)

    Perenboom, J.A.A.J.; Wiegers, S.A.J.; Christianen, P.C.M.; Zeitler, U.; Maan, J.C.

    2004-01-01

    For research in the highest continuous and pulsed magnetic fields large, complex and powerful installations are needed. A new 20 MW installation has been built at the University of Nijmegen. The ultra-low ripple power converter, delivering 40 kA at up to 500 V, provides the capability to perform exp

  7. Viscosity Reduction in Liquid Suspensions by Electric or Magnetic Fields

    Science.gov (United States)

    Tao, R.; Xu, X.

    Reducing the viscosity of liquid suspensions is of great importance in science and engineering. We present a theory and experiments that a suitable electric or magnetic field pulse can effectively reduce the viscosity for several hours with no appreciable change of temperature. Positive experimental results with magnetorheological fluids and crude oil suggest a broad range of practical applications.

  8. Stress Field of Straight Edge Dislocation in Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    LIU Zhao-long; HU Hai-yun; FAN Tian-you

    2007-01-01

    To study the changes in mechanical properties of materials within magnetic fields and the motion of dislocations,stress fields of dislocation in magnetic field need to be calculated.The straight edge dislocation is of basic importance in various defects.The stress field of straight edge dislocation in an external static magnetic field is determined by the theory of elasticity and electrodynamics according to the Volterra dislocation model for continuous media.This reduces to the known stress field when the magnet field is zero.The results can be used for further study on the strain energy of dislocations and the interactions between dislocations in magnetic fields.

  9. Diagnosis of solar chromospheric magnetic field

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Hongqi(张洪起)

    2002-01-01

    This paper discusses the measurements of the chromospheric magnetic field and the spatial configuration of the field at the lower solar atmosphere inferred by the distribution of the solar photospheric and chromospheric magnetic fields. Some questions in the study of the chromospheric magnetic field are also presented.

  10. The HMI Magnetic Field Pipeline

    Science.gov (United States)

    Hoeksema, Jon Todd; Liu, Y.; Schou, J.; Scherrer, P.; HMI Science Team

    2009-05-01

    The Helioseismic and Magnetic Imager (HMI) will provide frequent full-disk magnetic field data after launch of the Solar Dynamics Observatory (SDO), currently scheduled for fall 2009. 16 megapixel line-of-sight magnetograms (Blos) will be recorded every 45 seconds. A full set of polarized filtergrams needed to determine the vector magnetic field requires 90 seconds. Quick-look data will be available within a few minutes of observation. Quick-look space weather and browse products must have identified users, and the list currently includes full disk magnetograms, feature identification and movies, 12-minute disambiguated vector fields in active region patches, time evolution of AR indices, synoptic synchronic frames, potential and MHD model results, and 1 AU predictions. A more complete set of definitive science data products will be offered about a day later and come in three types. "Pipeline” products, such as full disk vector magnetograms, will be computed for all data on an appropriate cadence. A larger menu of "On Demand” products, such as Non-Linear Force Free Field snapshots of an evolving active region, will be produced whenever a user wants them. Less commonly needed "On Request” products that require significant project resources, such as a high resolution MHD simulation of the global corona, will be created subject to availability of resources. Further information can be found at the SDO Joint Science Operations Center web page, jsoc.stanford.edu

  11. SQUIDs De-fluxing Using a Decaying AC Magnetic Field

    Energy Technology Data Exchange (ETDEWEB)

    Matlashov, Andrei Nikolaevich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Semenov, Vasili Kirilovich [State Univ. of New York (SUNY), Plattsburgh, NY (United States); Anderson, Bill [Senior Scientific, LLC, Albuquerque, NM (United States)

    2016-06-08

    Flux trapping is the Achilles’ heel of all superconductor electronics. The most direct way to avoid flux trapping is a prevention of superconductor circuits from exposure to magnetic fields. Unfortunately this is not feasible if the circuits must be exposed to a strong DC magnetic field even for a short period of time. For example, such unavoidable exposures take place in superparamagnetic relaxation measurements (SPMR) and ultra-low field magnetic resonance imaging (ULF MRI) using unshielded thin-film SQUID-based gradiometers. Unshielded SQUIDs stop working after being exposed to DC magnetic fields of only a few Gauss in strength. In this paper we present experimental results with de-fluxing of planar thin-film LTS SQUID-based gradiometers using a strong decaying AC magnetic field. We used four commercial G136 gradiometers for SPMR measurements with up to a 10 mT magnetizing field. Strong 12.9 kHz decaying magnetic field pulses reliably return SQUIDs to normal operation 50 ms after zeroing the DC magnetizing field. This new AC de-fluxing method was also successfully tested with seven other different types of LTS SQUID sensors and has been shown to dissipate extremely low energy.

  12. Faraday rotation imaging microscope with microsecond pulse magnet

    Energy Technology Data Exchange (ETDEWEB)

    Suwa, Masayori, E-mail: msuwa@chem.sci.osaka-u.ac.jp [Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Tsukahara, Satoshi [Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Watarai, Hitoshi, E-mail: watarai@chem.sci.osaka-u.ac.jp [Institute for NanoScience Design, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)

    2015-11-01

    We have fabricated a high-performance Faraday rotation (FR) imaging microscope that uses a microsecond pulse magnet comprising an insulated gated bipolar transistor and a 2 μF capacitor. Our microscope produced images with greater stability and sensitivity than those of previous microscopes that used millisecond pulse magnet; these improvements are likely due to high repetition rate and negligible Joule heating effects. The mechanical vibrations in the magnet coil caused by the pulsed current were significantly reduced. The present FR microscope constructed an averaged image from 1000 FR images within 10 min under 1.7 T. Applications of the FR microscope to discriminating three benzene derivatives in micro-capillaries and oscillation-free imaging of spherical polystyrene and polymethyl methacrylate microparticles demonstrated its high performance. - Highlights: • A microsecond pulse magnet with high repetition rate of 10 Hz was fabricated. • Faraday rotation (FR) imaging microscope with the μs magnet was constructed. • Benzene derivatives in microcapillaries were distinguished with the FR microscope. • FR images of single polymer microspheres of 20 μm were correctly acquired. • Observed FR angles agreed quantitatively with those expected from Verdet constants.

  13. Field Theory for Coherent Optical Pulse Propagation

    CERN Document Server

    Park, Q H

    1997-01-01

    We introduce a new notion of "matrix potential" to nonlinear optical systems. In terms of a matrix potential $g$, we present a gauge field theoretic formulation of the Maxwell-Bloch equation that provides a semiclassical description of the propagation of optical pulses through resonant multi-level media. We show that the Bloch part of the equation can solved identically through $g$ and the remaining Maxwell equation becomes a second order differential equation with reduced set of variables due to the gauge invariance of the system. Our formulation clarifies the (nonabelian) symmetry structure of the Maxwell-Bloch equations for various multi-level media in association with symmetric spaces $G/H$. In particular, we associate nondegenerate two-level system for self-induced transparency with $G/H=SU(2)/U(1)$ and three-level $\\L $- or V-systems with $G/H = SU(3)/U(2)$. We give a detailed analysis for the two-level case in the matrix potential formalism, and address various new properties of the system including so...

  14. A Vorticity-Magnetic Field Dynamo Instability

    OpenAIRE

    1997-01-01

    We generalize the mean field magnetic dynamo to include local evolution of the mean vorticity in addition to the mean magnetic field. The coupled equations exhibit a general mean field dynamo instability that enables the transfer of turbulent energy to the magnetic field and vorticity on larger scales. The growth of the vorticity and magnetic field both require helical turbulence which can be supplied by an underlying global rotation. The dynamo coefficients are derived including the backreac...

  15. The effect of pulsed electric fields on carotenoids bioaccessibility

    NARCIS (Netherlands)

    Bot, Francesca; Verkerk, Ruud; Mastwijk, Hennie; Anese, Monica; Fogliano, Vincenzo; Capuano, Edoardo

    2018-01-01

    Tomato fractions were subjected to pulsed electric fields treatment combined or not with heating. Results showed that pulsed electric fields and heating applied in combination or individually induced permeabilization of cell membranes in the tomato fractions. However, no changes in β-carotene and

  16. Magnetic field of a combined plasma trap

    Science.gov (United States)

    Kotenko, V. G.; Moiseenko, V. E.; Ågren, O.

    2012-06-01

    This paper presents numerical simulations performed on the structure of a magnetic field created by the magnetic system of a combined plasma trap. The magnetic system includes the stellarator-type magnetic system and one of the mirror-type. For the stellarator type magnetic system the numeric model contains a magnetic system of an l=2 torsatron with the coils of an additional toroidal magnetic field. The mirror-type magnetic system element is considered as being single current-carrying turn enveloping the region of existence of closed magnetic surfaces of the torsatron. The calculations indicate the existence of a vast area of the values of the additional magnetic field magnitude and magnetic field of the single turn where, in principle, the implementation of the closed magnetic surface configuration is quite feasible.

  17. ANALYTIC EXPRESSION OF MAGNETIC FIELD DISTRIBUTION OF RECTANGULAR PERMANENT MAGNETS

    Institute of Scientific and Technical Information of China (English)

    苟晓凡; 杨勇; 郑晓静

    2004-01-01

    From the molecular current viewpoint,an analytic expression exactly describing magnetic field distribution of rectangular permanent magnets magnetized sufficiently in one direction was derived from the Biot-Savart's law. This expression is useful not only for the case of one rectangular permanent magnet bulk, but also for that of several rectangular permanent magnet bulks. By using this expression,the relations between magnetic field distribution and the size of rectangular permanent magnets as well as the magnitude of magnetic field and the distance from the point in the space to the top (or bottom) surface of rectangular permanent magnets were discussed in detail. All the calculating results are consistent with experimental ones. For transverse magnetic field which is a main magnetic field of rectangular permanent magnets,in order to describe its distribution,two quantities,one is the uniformity in magnitude and the other is the uniformity in distribution of magnetic field,were defined. Furthermore, the relations between them and the geometric size of the magnet as well as the distance from the surface of permanent magnets were investigated by these formulas. The numerical results show that the geometric size and the distance have a visible influence on the uniformity in magnitude and the uniformity in distribution of the magnetic field.

  18. On a Correlation between the Ionospheric Electric Field and the Time Derivative of the Magnetic Field

    Directory of Open Access Journals (Sweden)

    R. R. Ilma

    2012-01-01

    Full Text Available A correlation of the ionospheric electric field and the time derivative of the magnetic field was noticed over thirty years ago and has yet to be explained. Here we report on another set of examples during the superstorm of November 2004. The electric field in the equatorial ionosphere, measured with the Jicamarca incoherent scatter radar, exhibited a 3 mV/m electric field pulse that was not seen in the interplanetary medium. It was, however, accompanied by a correlation with the time derivative of the magnetic field measured at two points in Peru. Our inclination was to assume that the field was inductive. However, the time scale of the pulse was too short for the magnetic field to penetrate the crust of the Earth. This means that the area threaded by ∂B/∂t was too small to create the observed electric field by induction. We suggest that the effect was caused by a modulation of the ring current location relative to the Earth due to the electric field. This electric field is required, as the magnetic field lines are considered frozen into the plasma in the magnetosphere. The closer location of the ring current to the Earth in turn increased the magnetic field at the surface.

  19. Field and Thermal Characteristics of Magnetizing Fixture

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    This paper describes field modeling and thermal modeling for magnetizing fixture. As the detailed characteristics of magnetizing fixture can be obtained, the efficient design of magnetizer which produce desired magnet will be possible using our modeling. For field modeling finite-element analysis is used as part of the design and analysis process for magnetizing fixture. The thermal modeling method of magnetizing fixture resistor uses multi-lumped model with equivalent thermal resistance and thermal capacitance.

  20. Conceptual design for the superconducting magnet system of a pulsed DEMO reactor

    Energy Technology Data Exchange (ETDEWEB)

    Duchateau, J.-L., E-mail: jean-luc.duchateau@cea.fr [CEA/IRFM, 13108 St. Paul lez Durance Cedex (France); Hertout, P.; Saoutic, B.; Magaud, P.; Artaud, J.-F.; Giruzzi, G.; Bucalossi, J.; Johner, J.; Sardain, P.; Imbeaux, F.; Ané, J.-M.; Li-Puma, A. [CEA/IRFM, 13108 St. Paul lez Durance Cedex (France)

    2013-10-15

    Highlights: ► A 1D design approach of a pulsed DEMO reactor is presented. ► The main CS and TF conductor design criteria are presented. ► A typical major radius for a 2 GW DEMO is 9 m. ► A typical plasma magnetic field is 4.9 T. ► The pulse duration is 1.85 h for an aspect ratio of 3. -- Abstract: A methodology has been developed to consistently investigate, taking into account main reactor components, possible magnet solutions for a pulsed fusion reactor aiming at a large solenoid flux swing duration within the 2–3 h range. In a conceptual approach, investigations are carried out in the equatorial plane, taking into account the radial extension of the blanket-shielding zone, of the toroidal field magnet system inner leg and of the central solenoid for estimation of the pulsed swing. Design criteria are presented for the radial extension of the superconducting magnets, which is mostly driven by the structures (casings and conductor jacket). Typical available cable current densities are presented as a function of the magnetic field and of the temperature margin. The magnet design criteria have been integrated into SYCOMORE, a code for reactor modeling presently in development at CEA/IRFM in Cadarache, using the tools of the EFDA Integrated Tokamak Modeling task force. Possible solutions are investigated for a 2 GW fusion power reactor with different aspect ratios. The final adjustment of the DEMO pulsed reactor parameters will have to be consistently done, considering all reactor components, when the final goals of the machine will be completely clarified.

  1. Magnetic fields for fluid motion.

    Science.gov (United States)

    Weston, Melissa C; Gerner, Matthew D; Fritsch, Ingrid

    2010-05-01

    Three forces induced by magnetic fields offer unique control of fluid motion and new opportunities in microfluidics. This article describes magnetoconvective phenomena in terms of the theory and controversy, tuning by redox processes at electrodes, early-stage applications in analytical chemistry, mature applications in disciplines far afield, and future directions for micro total analysis systems. (To listen to a podcast about this article, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html .).

  2. Switching field reduction of a perpendicular magnetic nanodot in a microwave magnetic field emitted from a spin-torque oscillator

    Science.gov (United States)

    Suto, Hirofumi; Kanao, Taro; Nagasawa, Tazumi; Kudo, Kiwamu; Mizushima, Koichi; Sato, Rie

    2017-03-01

    We demonstrate microwave-assisted magnetization switching of a perpendicular magnetic nanodot in a microwave stray field from a spin-torque oscillator (STO). The switching field decreases when the STO is operated by applying a current. The switching field reduction is almost the same as that in a microwave magnetic field generated by a signal generator despite the fluctuations of the STO oscillation. The switching field distribution, however, is broader when the STO is used. We also examine the magnetization switching process in the nanosecond region by applying a nanosecond-order pulse current to the STO and measuring the STO signal waveform. The onset of the STO oscillation and subsequent assisted switching occur within a few nanoseconds.

  3. Deformation of Water by a Magnetic Field

    Science.gov (United States)

    Chen, Zijun; Dahlberg, E. Dan

    2011-03-01

    After the discovery that superconducting magnets could levitate diamagnetic objects,1,2 researchers became interested in measuring the repulsion of diamagnetic fluids in strong magnetic fields,3-5 which was given the name "The Moses Effect."5 Both for the levitation experiments and the quantitative studies on liquids, the large magnetic fields necessary were produced by superconducting magnets.

  4. Bifurcation physics of magnetic islands and stochasticity explored by heat pulse propagation studies in toroidal plasmas

    Science.gov (United States)

    Ida, K.; Kobayashi, T.; Yoshinuma, M.; Suzuki, Y.; Narushima, Y.; Evans, T. E.; Ohdachi, S.; Tsuchiya, H.; Inagaki, S.; Itoh, K.

    2016-09-01

    Bifurcation physics of a magnetic island was investigated using the heat pulse propagation technique produced by the modulation of electron cyclotron heating. There are two types of bifurcation phenomena observed in a large helical device (LHD) and DIII-D. One is a bifurcation of the magnetic topology between nested and stochastic fields. The nested state is characterized by the bi-directional (inward and outward) propagation of the heat pulse with slow propagation speed. The stochastic state is characterized by the fast propagation of the heat pulse with electron temperature flattening. The other bifurcation is between the magnetic island with larger thermal diffusivity and that with smaller thermal diffusivity. The damping of toroidal flow is observed at the O-point of the magnetic island both in helical plasmas and in tokamak plasmas during a mode locking phase with strong flow shears at the boundary of the magnetic island. Associated with the stochastization of the magnetic field, the abrupt damping of toroidal flow is observed in LHD. The toroidal flow shear shows a linear decay, while the ion temperature gradient shows an exponential decay. This observation suggests that this flow damping is due to the change in the non-diffusive term of momentum transport.

  5. A magnetic pulse does not affect homing pigeon navigation: a GPS tracking experiment.

    Science.gov (United States)

    Holland, Richard; Filannino, Caterina; Gagliardo, Anna

    2013-06-15

    The cues by which homing pigeons are able to return to a home loft after displacement to unfamiliar release sites remain debated. A number of experiments in which migratory birds have been treated with a magnetic pulse have produced a disruption in their orientation, which argues that a ferrimagnetic sense is used for navigation in birds. One previous experiment has also indicated an effect of magnetic pulses on homing pigeon navigation, although with inconsistent results. Previous studies have shown that some magnetic-related information is transmitted by the trigeminal nerve to the brain in some bird species, including the homing pigeon. The function of this information is still unclear. It has been suggested that this information is important for navigation. Previous studies with trigeminal nerve lesioned homing pigeons have clearly shown that the lack of trigeminally mediated information, even if magnetic, is not crucial for homing performance. However, this result does not completely exclude the possibility that other ferrimagnetic receptors in the homing pigeon play a role in navigation. Additionally, recent studies on homing pigeons suggested the existence of a ferrimagnetic sense in a novel location presumably located in the inner ear (lagena). In the present study, we tested whether any ferrimagnetic magnetoreceptors, irrespective of their location in the bird's head, are involved in pigeons' homing. To do this, we treated homing pigeons with a strong magnetic pulse before release, tracked birds with GPS loggers and analyzed whether this treatment affected homing performance. In the single previous magnetic pulse experiment on homing pigeons, only initial orientation at a release site was considered and the results were inconsistent. We observed no effect of the magnetic pulse at any of the sites used on initial orientation, homing performance, tortuosity or track efficiency, which does not support a role for the ferrimagnetic sense in homing pigeon

  6. Magnet Design and Analysis of a 40 Tesla Long Pulse System Energized by a Battery Bank

    Science.gov (United States)

    Lv, Y. L.; Peng, T.; Wang, G. B.; Ding, T. H.; Han, X. T.; Pan, Y.; Li, L.

    2013-03-01

    A 40 tesla long pulse magnet and a battery bank as the power supply have been designed. This is now under construction at the Wuhan National High Magnetic Field Center. The 22 mm bore magnet will generate smooth pulses with duration 1 s and rise time 0.5 s. The battery bank consists of 945 12V/200 Ah lead-acid battery cells. The magnet and battery bank were optimized by codes developed in-house and by ANSYS. The coil was made from soft copper with internal reinforcement by fiber-epoxy composite; it is divided into two sections connected in series. The inner section consists of helix coils with each layer reinforced by Zylon composite. The outer section will be wound from copper sheet and externally reinforced by carbon fiber composite.

  7. Excitation of magnetization using a modulated radiation damping field.

    Science.gov (United States)

    Walls, Jamie D; Huang, Susie Y; Lin, Yung-Ya

    2006-10-12

    In this work, pulsed-field gradients are used to modulate the radiation damping field generated by the detection coil in an NMR experiment in order that spins with significantly different chemical shifts can affect one another via the radiation damping field. Experiments performed on solutions of acetone/water and acetone/DMSO/water demonstrate that spins with chemical shift differences much greater than the effective radiation damping field strength can still be coupled by modulating the radiation damping field. Implications for applications in high-field NMR and for developing sensitive magnetization detectors are discussed.

  8. Passive Magnetic Shielding in Gradient Fields

    CERN Document Server

    Bidinosti, C P

    2013-01-01

    The effect of passive magnetic shielding on dc magnetic field gradients imposed by both external and internal sources is studied. It is found that for concentric cylindrical or spherical shells of high permeability material, higher order multipoles in the magnetic field are shielded progressively better, by a factor related to the order of the multipole. In regard to the design of internal coil systems for the generation of uniform internal fields, we show how one can take advantage of the coupling of the coils to the innermost magnetic shield to further optimize the uniformity of the field. These results demonstrate quantitatively a phenomenon that was previously well-known qualitatively: that the resultant magnetic field within a passively magnetically shielded region can be much more uniform than the applied magnetic field itself. Furthermore we provide formulae relevant to active magnetic compensation systems which attempt to stabilize the interior fields by sensing and cancelling the exterior fields clos...

  9. Strong-field short-pulse nondipole dynamics

    DEFF Research Database (Denmark)

    Dimitrovski, Darko; Førre, Morten; Madsen, Lars Bojer

    2009-01-01

    We present a quantitative investigation of strong-field short-pulse nondipole dynamics in laser-matter interactions. We find excellent agreement between ab initio numerical and analytic results obtained using the Magnus expansion. We show that in the short-pulse limit, ultrafast transfer and cont......We present a quantitative investigation of strong-field short-pulse nondipole dynamics in laser-matter interactions. We find excellent agreement between ab initio numerical and analytic results obtained using the Magnus expansion. We show that in the short-pulse limit, ultrafast transfer...

  10. Isolated Attosecond Pulses using a Detuned Second-harmonic Field

    Energy Technology Data Exchange (ETDEWEB)

    Merdji, Hamed; /Saclay /SLAC, PULSE; Auguste, Thierry; Boutu, Willem; Caumes, J.-Pascal; Carre, Bertrand; /Saclay; Pfeifer, Thomas; Jullien, Aurelie; Neumark, Daniel M.; Leone, Stephen R.; /UC, Berkeley /LBL, Berkeley

    2007-11-07

    Calculations are presented for the generation of an isolated attosecond pulse in a multicycle two-color strong-field regime. We show that the recollision of the electron wave packet can be confined to half an optical cycle using pulses of up to 40 fs in duration. The scheme is proven to be efficient using two intense beams, one producing a strong field at {omega} and the other a strong field detuned from 2{omega}. The slight detuning {delta}{omega} of the second harmonic is used to break the symmetry of the electric field over many optical cycles and provides a coherent control for the formation of an isolated attosecond pulse.

  11. STUDY ON INACTIVATION OF HETEROTROPHIC BACTERIA IN THE CIRCULATING COOLING WATER SYSTEM OF POWER PLANT BY SWEET PULSED MAGNETIC FIELD%扫频脉冲磁场对电厂循环冷却水中异养菌的灭活研究

    Institute of Scientific and Technical Information of China (English)

    武红梅; 刘智安; 常英; 薛金英; 刘洋; 周斐博

    2011-01-01

    The effect of sweep pulsed magnetic field on heterotrophic bacteria of power plant circulating cooling water was studied and the inactivation key factors were analyzed.It was found that pulsed magnetic field has an inactivated role in heterotrophic bacteria.The efficiency depends on the frequency and output voltage.The inactivated rate of magnetic field is increased with the increasing of the temperature and the single magnetic treatment time.With the sweep pulse magnetic field 100~1 000 Hz,the single magnetic treatment time 15s,output voltage 3V,temperature 45℃ the inactivated rate is 78.8%.%研究了扫频脉冲磁场对电厂循环冷却水中异养菌的影响,并对灭活关键因素进行了分析。实验结果表明,脉冲磁场对电厂循环冷却水中的异养菌有灭活作用。灭活率对频率和输出电压具有选择性,并且随着作用时间和温度的升高而升高。在扫频范围100~1 000Hz、输出电压3 V、单次作用时间为15 s,温度45℃时,异养菌灭活率可达78.8%。

  12. Magnetic field perturbartions in closed-field-line systems with zero toroidal magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Mauel, M; Ryutov, D; Kesner, J

    2003-12-02

    In some plasma confinement systems (e.g., field-reversed configurations and levitated dipoles) the confinement is provided by a closed-field-line poloidal magnetic field. We consider the influence of the magnetic field perturbations on the structure of the magnetic field in such systems and find that the effect of perturbations is quite different from that in the systems with a substantial toroidal field. In particular, even infinitesimal perturbations can, in principle, lead to large radial excursions of the field lines in FRCs and levitated dipoles. Under such circumstances, particle drifts and particle collisions may give rise to significant neoclassical transport. Introduction of a weak regular toroidal magnetic field reduces radial excursions of the field lines and neoclassical transport.

  13. Fabrication of pulsed magnets with a linear-type coil-winding machine

    Science.gov (United States)

    Suzuki, O.; Sakamoto, K.; Imanaka, Y.; Kido, G.

    2001-01-01

    We developed a linear-type coil-winding machine for the fabrication of pulsed magnets. This machine is compact and makes the process of winding a wire easier. The wire is led to a coil shaft through a pair of timing-belts. Kapton tape and Zylon fiber are wrapped on the wire by interlocking with the drive part of the timing-belts. A test magnet fabricated with the linear-type coil-winding machine generates magnetic fields above 63 T.

  14. Effects of pulsed electromagnetic fields on benign prostate hyperplasia.

    Science.gov (United States)

    Giannakopoulos, Xenophon K; Giotis, Christos; Karkabounas, Spyridon Ch; Verginadis, Ioannis I; Simos, Yannis V; Peschos, Dimitrios; Evangelou, Angelos M

    2011-12-01

    Benign prostate hyperplasia (BPH) has been treated with various types of electromagnetic radiation methods such as transurethral needle ablation (TUNA), interstitial laser therapy (ILC), holmium laser resection (HoLRP). In the present study, the effects of a noninvasive method based on the exposure of patients with BPH to a pulsative EM Field at radiofrequencies have been investigated. Twenty patients with BPH, aging 68-78 years old (y.o), were enrolled in the study. Patients were randomly divided into two groups: the treatment group (10 patients, 74.0 ± 5.7 y.o) treated with the α-blocker Alfusosin, 10 mg/24 h for at least 4 weeks, and the electromagnetic group (10 patients, 73.7 ± 6.3 y.o) exposed for 2 weeks in a very short wave duration, pulsed electromagnetic field at radiofrequencies generated by an ion magnetic inductor, for 30 min daily, 5 consecutive days per week. Patients of both groups were evaluated before and after drug and EMF treatment by values of total PSA and prostatic PSA fraction, acid phosphate, U/S estimation of prostate volume and urine residue, urodynamic estimation of urine flow rate, and International Prostate Symptom Score (IPSS). There was a statistically significant decrease before and after treatment of IPSS (P < 0.02), U/S prostate volume (P < 0.05), and urine residue (P < 0.05), as well as of mean urine flow rate (P < 0.05) in patients of the electromagnetic group, in contrast to the treatment group who had only improved IPSS (P < 0.05). There was also a significant improvement in clinical symptoms in patients of the electromagnetic group. Follow-up of the patients of this group for one year revealed that results obtained by EMFs treatment are still remaining. Pulsed electromagnetic field at radiofrequencies may benefit patients with benign prostate hyperplasia treated by a non-invasive method.

  15. Bats respond to very weak magnetic fields.

    Directory of Open Access Journals (Sweden)

    Lan-Xiang Tian

    Full Text Available How animals, including mammals, can respond to and utilize the direction and intensity of the Earth's magnetic field for orientation and navigation is contentious. In this study, we experimentally tested whether the Chinese Noctule, Nyctalus plancyi (Vespertilionidae can sense magnetic field strengths that were even lower than those of the present-day geomagnetic field. Such field strengths occurred during geomagnetic excursions or polarity reversals and thus may have played an important role in the evolution of a magnetic sense. We found that in a present-day local geomagnetic field, the bats showed a clear preference for positioning themselves at the magnetic north. As the field intensity decreased to only 1/5th of the natural intensity (i.e., 10 μT; the lowest field strength tested here, the bats still responded by positioning themselves at the magnetic north. When the field polarity was artificially reversed, the bats still preferred the new magnetic north, even at the lowest field strength tested (10 μT, despite the fact that the artificial field orientation was opposite to the natural geomagnetic field (P<0.05. Hence, N. plancyi is able to detect the direction of a magnetic field even at 1/5th of the present-day field strength. This high sensitivity to magnetic fields may explain how magnetic orientation could have evolved in bats even as the Earth's magnetic field strength varied and the polarity reversed tens of times over the past fifty million years.

  16. Hybrid Shielding for Magnetic Fields

    Science.gov (United States)

    Mullins, David; Royal, Kevin

    2017-01-01

    Precision symmetry measurements such as the search for the electric dipole moment of the neutron require magnetic shielding rooms to reduce the ambient field to the pT scale. The massive mu-metal sheets and large separation between layers make these shield rooms bulky and expensive. Active field cancellation systems used to reduce the surrounding field are limited in uniformity of cancellation. A novel approach to reducing the space between shield layers and increasing the effectiveness of active cancellation is to combine the two systems into a hybrid system, with active and passive layers interspersed. We demonstrate this idea in a prototype with an active layer sandwiched between two passive layers of shielding.

  17. Manifestations of Magnetic Field Inhomogeneities

    Indian Academy of Sciences (India)

    Lawrence Rudnick

    2011-12-01

    Both observations and simulations reveal large inhomogeneities in magnetic field distributions in diffuse plasmas. Incorporating these inhomogeneities into various calculations can significantly change the inferred physical conditions. In extragalactic sources, e.g., these can compromise analyses of spectral ageing, which I will illustrate with some current work on cluster relics. I also briefly re-examine the old issue of how inhomogeneous fields affect particle lifetimes; perhaps not surprisingly, the next generation of radio telescopes are unlikely to find many sources that can extend their lifetimes from putting relativistic electrons into a low-field ‘freezer’. Finally, I preview some new EVLA results on the complex relic in Abell 2256, with implications for the interspersing of its relativistic and thermal plasmas.

  18. A new ring-shape high-temperature superconducting trapped-field magnet

    Science.gov (United States)

    Sheng, Jie; Zhang, Min; Wang, Yawei; Li, Xiaojian; Patel, Jay; Yuan, Weijia

    2017-09-01

    This paper presents a new trapped-field magnet made of second-generation high-temperature superconducting (2G HTS) rings. This so-called ring-shape 2G HTS magnet has the potential to provide much stronger magnetic fields relative to existing permanent magnets. Compared to existing 2G HTS trapped- field magnets, e.g. 2G HTS bulks and stacks, this new ring-shape 2G HTS magnet is more flexible in size and can be made into magnets with large dimensions for industrial applications. Effective magnetization is the key to being able to use trapped-field magnets. Therefore, this paper focuses on the magnetization mechanism of this new magnet using both experimental and numerical methods. Unique features have been identified and quantified for this new type of HTS magnet in the field cooling and zero field cooling process. The magnetization mechanism can be understood by the interaction between shielding currents and the penetration of external magnetic fields. An accumulation in the trapped field was observed by using multiple pulse field cooling. Three types of demagnetization were studied to measure the trapped-field decay for practical applications. Our results show that this new ring-shape HTS magnet is very promising in the trapping of a high magnetic field. As a super-permanent magnet, it will have a significant impact on large-scale industrial applications, e.g. the development of HTS machines with a very high power density and HTS magnetic resonance imaging devices.

  19. Effects of magnetic field on fluidization properties of magnetic pearls

    Institute of Scientific and Technical Information of China (English)

    Maoming Fan; Zhenfu Luo; Yuemin Zhao; Qingru Chen; Daniel Tao; Xiuxiang Tao; Zhenqiang Chen

    2007-01-01

    An experimental study of the influence of external magnetic field on the fluidization behavior of magnetic pearls was carried out. Magnetic pearls are a magnetic form of iron oxide that mainly consists of Fe2O3 which are recovered from a high-volume power plant fly ash from pulverized coal combustion. Due to its abundance, low price and particular physical and chemical properties, magnetic pearls can be used as a heavy medium for minerals or solid waste dry separation based on density difference. This paper introduces the properties of magnetic pearls and compares the performance of magnetic pearls fluidised bed operation with or without an external magnetic field. Experimental results show that an external magnetic field significantly improves the fluidization performance of magnetic pearls such as uniformity and stability.

  20. Magnetic Helicity and Large Scale Magnetic Fields: A Primer

    CERN Document Server

    Blackman, Eric G

    2014-01-01

    Magnetic fields of laboratory, planetary, stellar, and galactic plasmas commonly exhibit significant order on large temporal or spatial scales compared to the otherwise random motions within the hosting system. Such ordered fields can be measured in the case of planets, stars, and galaxies, or inferred indirectly by the action of their dynamical influence, such as jets. Whether large scale fields are amplified in situ or a remnant from previous stages of an object's history is often debated for objects without a definitive magnetic activity cycle. Magnetic helicity, a measure of twist and linkage of magnetic field lines, is a unifying tool for understanding large scale field evolution for both mechanisms of origin. Its importance stems from its two basic properties: (1) magnetic helicity is typically better conserved than magnetic energy; and (2) the magnetic energy associated with a fixed amount of magnetic helicity is minimized when the system relaxes this helical structure to the largest scale available. H...

  1. Broadband finite-pulse radio-frequency-driven recoupling (fp-RFDR) with (XY8)4(1) super-cycling for homo-nuclear correlations in very high magnetic fields at fast and ultra-fast MAS frequencies.

    Science.gov (United States)

    Shen, Ming; Hu, Bingwen; Lafon, Oliver; Trébosc, Julien; Chen, Qun; Amoureux, Jean-Paul

    2012-10-01

    We demonstrate that inter-residue (13)C-(13)C proximities (of about 380 pm) in uniformly (13)C-labeled proteins can be probed by applying robust first-order recoupling during several milliseconds in single-quantum single-quantum dipolar homo-nuclear correlation (SQ-SQ D-HOMCOR) 2D experiments. We show that the intensity of medium-range homo-nuclear correlations in these experiments is enhanced using broadband first-order finite-pulse radio-frequency-driven recoupling (fp-RFDR) NMR sequence with a nested (XY8)4(1) super-cycling. The robustness and the efficiency of the fp-RFDR-(XY8)4(1) method is demonstrated at high magnetic field (21.1T) and high Magic-Angle Spinning (MAS) speeds (up to 60 kHz). The introduced super-cycling, formed by combining phase inversion and a global four-quantum phase cycle, improves the robustness of fp-RFDR to (i) chemical shift anisotropy (CSA), (ii) spread in isotropic chemical shifts, (iii) rf-inhomogeneity and (iv) hetero-nuclear dipolar couplings for long recoupling times. We show that fp-RFDR-(XY8)4(1) is efficient sans (1)H decoupling, which is beneficial for temperature-sensitive biomolecules. The efficiency and the robustness of fp-RFDR-(XY8)4(1) is investigated by spin dynamics numerical simulations as well as solid-state NMR experiments on [U-(13)C]-L-histidine·HCl, a tetra-peptide (Fmoc-[U-(13)C,(15)N]-Val-[U-(13)C,(15)N]-Ala-[U-(13)C,(15)N]-Phe-Gly-t-Boc) and Al(PO(3))(3).

  2. Interaction between two magnetic dipoles in a uniform magnetic field

    Directory of Open Access Journals (Sweden)

    J. G. Ku

    2016-02-01

    Full Text Available A new formula for the interaction force between two magnetic dipoles in a uniform magnetic field is derived taking their mutual magnetic interaction into consideration and used to simulate their relative motion. Results show that when the angle β between the direction of external magnetic field and the centerline of two magnetic dipoles is 0 ° or 90 °, magnetic dipoles approach each other or move away from each other in a straight line, respectively. And the time required for them to contact each other from the initial position is related to the specific susceptibility and the diameter of magnetic particles, medium viscosity and magnetic field strength. When β is between 0 ° and 90 °, magnetic dipole pair performs approximate elliptical motion, and the motion trajectory is affected by the specific susceptibility, diameter and medium viscosity but not magnetic field strength. However, time required for magnetic dipoles to complete the same motion trajectory is shorter when adopting stronger magnetic field. Moreover, the subsequent motion trajectory of magnetic dipoles is ascertained once the initial position is set in a predetermined motion trajectory. Additionally, magnetic potential energy of magnetic dipole pairs is transformed into kinetic energy and friction energy during the motion.

  3. Effective magnetic moment of neutrinos in strong magnetic fields

    CERN Document Server

    Pérez, A; Masood, S S; Gaitan, R; Rodríguez, S

    2002-01-01

    In this paper we compute the effective magnetic moment of neutrinos propagating in dense high magnetized medium. Taking typical values of magnetic field and densities of astrophysical objects (such as the cores of supernovae and neutron stars) we obtain an effective type of dipole magnetic moment in agreement with astrophysical and cosmological bounds. (Author)

  4. Plasma opening switch with extrinsic magnetic field

    CERN Document Server

    Dolgachev, G; Maslennikov, D

    2001-01-01

    Summary form only given, as follows. We have demonstrated in series of experiments that plasma opening switch (POS) switching voltage (UPOS) is defined by energy density (w) deposited in the POS plasma. If we then consider a plasma erosion mainly responsible for the effect of POS switching (the erosion effect could be described by Hall or Child-Langmuir models) the energy density (w) could be measured as a function of a system "macro-parameter" such as the initial charging voltage of the capacity storage system (the Marx pulsed voltage generator) UMarx. The POS voltage in this case could be given by UPOS"aw=aUMarx4/7, where a is a constant. This report demonstrates that for the high-impedance POS which has limited charge density transferred through the POS plasma a"2.5 (MV3/7) with no external magnetic field applied. The use of the extrinsic magnetic field allows to increase a up to 3.6 (MV3/7) and to achieve higher voltages at the opening phase - UPOS=3.6UMarx4/7. To verify this approach set of experimental ...

  5. A compact high-voltage pulse generator based on pulse transformer with closed magnetic core.

    Science.gov (United States)

    Zhang, Yu; Liu, Jinliang; Cheng, Xinbing; Bai, Guoqiang; Zhang, Hongbo; Feng, Jiahuai; Liang, Bo

    2010-03-01

    A compact high-voltage nanosecond pulse generator, based on a pulse transformer with a closed magnetic core, is presented in this paper. The pulse generator consists of a miniaturized pulse transformer, a curled parallel strip pulse forming line (PFL), a spark gap, and a matched load. The innovative design is characterized by the compact structure of the transformer and the curled strip PFL. A new structure of transformer windings was designed to keep good insulation and decrease distributed capacitance between turns of windings. A three-copper-strip structure was adopted to avoid asymmetric coupling of the curled strip PFL. When the 31 microF primary capacitor is charged to 2 kV, the pulse transformer can charge the PFL to 165 kV, and the 3.5 ohm matched load can deliver a high-voltage pulse with a duration of 9 ns, amplitude of 84 kV, and rise time of 5.1 ns. When the load is changed to 50 ohms, the output peak voltage of the generator can be 165 kV, the full width at half maximum is 68 ns, and the rise time is 6.5 ns.

  6. Magnetic field penetration of erosion switch plasmas

    Science.gov (United States)

    Mason, Rodney J.; Jones, Michael E.; Grossmann, John M.; Ottinger, Paul F.

    1988-10-01

    Computer simulations demonstrate that the entrainment (or advection) of magnetic field with the flow of cathode-emitted electrons can constitute a dominant mechanism for the magnetic field penetration of erosion switch plasmas. Cross-field drift in the accelerating electric field near the cathode starts the penetration process. Plasma erosion propagates the point for emission and magnetic field injection along the cathode toward the load-for the possibility of rapid switch opening.

  7. Magnetic field reversals and galactic dynamos

    OpenAIRE

    2012-01-01

    We argue that global magnetic field reversals similar to those observed in the Milky Way occur quite frequently in mean-field galactic dynamo models that have relatively strong, random, seed magnetic fields that are localized in discrete regions. The number of reversals decreases to zero with reduction of the seed strength, efficiency of the galactic dynamo and size of the spots of the seed field. A systematic observational search for magnetic field reversals in a representative sample of spi...

  8. [Mechanism of ablation with nanosecond pulsed electric field].

    Science.gov (United States)

    Cen, Chao; Chen, Xin-hua; Zheng, Shu-sen

    2015-11-01

    Nanosecond pulsed electric field ablation has been widely applied in clinical cancer treatment, while its molecular mechanism is still unclear. Researchers have revealed that nanosecond pulsed electric field generates nanopores in plasma membrane, leading to a rapid influx of Ca²⁺; it has specific effect on intracellular organelle membranes, resulting in endoplasmic reticulum injuries and mitochondrial membrane potential changes. In addition, it may also change cellular morphology through damage of cytoskeleton. This article reviews the recent research advances on the molecular mechanism of cell membrane and organelle changes induced by nanosecond pulsed electric field ablation.

  9. Energy-spread measurement of triple-pulse electron beams based on the magnetic dispersion principle

    CERN Document Server

    Wang, Yi; Yang, Zhiyong; Zhang, Huang; Ding, Hengsong; Yang, Anmin; Wang, Minhong

    2016-01-01

    The energy-spread of the triple-pulse electron beam generated by the Dragon-II linear induction accelerator is measured using the method of energy dispersion in the magnetic field. A sector magnet is applied for energy analyzing of the electron beam, which has a bending radius of 300 mm and a deflection angle of 90 degrees. For each pulse, both the time-resolved and the integral images of the electron position at the output port of the bending beam line are recorded by a streak camera and a CCD camera, respectively. Experimental results demonstrate an energy-spread of less than +-2.0% for the electron pulses. The cavity voltage waveforms obtained by different detectors are also analyzed for comparison.

  10. GigaGauss magnetic fields in under-dense plasma

    CERN Document Server

    Lecz, Zsolt; Seryi, Andrei; Andreev, Alexander

    2016-01-01

    Magnetic fields have a crucial role in physics at all scales, from synchrotrons and laser-driven plasma accelerators to astrophysics and nanotechnology. Large field strengths, beside the guiding of relativistic particles along a shorter curvature, allows the investigation of material in extreme conditions existing only in exotic astro-objects like neutron stars or pulsars. Here we propose a method for generating magnetic field on the GigaGauss level in under-dense plasma using high intensity laser pulses with azimuthally non-uniform intensity distribution. The interaction is studied with the help of three-dimensional particle-in-cell plasma simulation code. Beside the standard wake-field and bubble generation, such laser beam induces the rotational motion of electrons at the edge of evacuated plasma region. The combined axial magnetic and electric fields form a compact source of both high frequency radiation, due to coherent synchrotron emission, and low emittance, high density relativistic electron bunches. ...

  11. 强脉冲磁场冲击处理对铝基复合材料塑性的影响机制∗%Mechanism of high pulsed magnetic field treatment of the plasticity of aluminum matrix comp osites

    Institute of Scientific and Technical Information of China (English)

    王宏明; 李沛思; 郑瑞; 李桂荣; 袁雪婷

    2015-01-01

    For aluminum matrix composite, the introduced particles will strengthen the matrix, but as the obstacles, the heterogeneous particles will hinder the dislocation movement, generate uneven material structure, and may become a source of stress concentration. Therefore, they are detrimental severely to the elongation and plasticity of composite. It is known that dislocations exhibit a paramagnetic behavior because they contain paramagnetic centers including localized electrons, holes, triplet excitons, ion radicals, etc. The initial radical pair of the dislocation-obstacle S (spin angular momentum)=± 1/2 is in a singlet state, and the total spin of the radical pair is 0 and in the antiparallel spin direction, offsetting a magnetism of the radical pair. The magnetic field can change the spin direction from singlet state to triplet state. In the triplet state the electron spin is 1 and in the same spin direction. A strong bond of the dislocation-obstacle is formed only in the singlet state when the spins of the two electrons are antiparallel. So an obstacle is able to pin a dislocation only if the radical pair is in the singlet state. Under the condition of high pulsed magnetic field treatment (HPMFT) the conversion of electronic spin will be a fundamental cause of dislocation motion along a glide plane. The movement of pinned dislocations will change the material microstructure and influence the performance of material. By comparing the microstructural evolutions and the residual stresses of samples subjected to HPMFT with different values of magnetic induced density (B), the positive influence of magnetoplastic effect on the plasticity of aluminum matrix composite is investigated in this paper. The results show that the dislocation density is significantly increased when B changes from 2 T to 4 T. When B = 4 T the dislocation density is enhanced by 3.1 times compared with that of the sample without HPMFT. Moreover, the residual stress is reduced apparently from 41

  12. In-situ fabrication of particulate reinforced aluminum matrix composites under high-frequency pulsed electromagnetic field

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Pulsed magnetic field is generated when imposing pulse signal on high-frequency magnetic field. Distribution of the inner magnetic intensity in induction coils tends to be uniform. Furthermore oscillation and disturbance phenomena appear in the melt. Insitu Al2O3 and Al3Zr particulate reinforced aluminum matrix composites have been synthesized by direct melt reaction using Al-Zr(CO3)2 components under a foreign field. The size of reinforced particulates is 2-3 μm. They are well distributed in the matrix.Thermodynamic and kinetic analysis show that high-frequency pulsed magnetic field accelerates heat and mass transfer processes and improves the kinetic condition of in-situ fabrication.

  13. Megagauss magnetic fields in ultra-intense laser generated dense plasmas

    Science.gov (United States)

    Shaikh, Moniruzzaman; Lad, Amit D.; Jana, Kamalesh; Sarkar, Deep; Dey, Indranuj; Kumar, G. Ravindra

    2017-01-01

    Table-top terawatt lasers can create relativistic light intensities and launch megaampere electron pulses in a solid. These pulses induce megagauss (MG) magnetic pulses, which in turn strongly affect the hot electron transport via electromagnetic instabilities. It is therefore crucial to characterize the MG magnetic fields in great detail. Here, we present measurements of the spatio-temporal evolution of MG magnetic fields produced by a high contrast (picosecond intensity contrast 10-9) laser in a dense plasma on a solid target. The MG magnetic field is measured using the magneto-optic Cotton-Mouton effect, with a time delayed second harmonic (400 nm) probe. The magnetic pulse created by the high contrast laser in a glass target peaks much faster and has a more rapid fall than that induced by a low contrast (10-6) laser.

  14. 25--30 T water cooled pulse magnet concept for neutron scattering experiment

    Energy Technology Data Exchange (ETDEWEB)

    Eyssa, Y.M.; Walsh, R.P.; Miller, J.R.; Pernambuco-Wise, P.; Bird, M.D.; Schneider-Muntau, H.J. [National High Magnetic Field Lab., Tallahassee, FL (United States); Boeing, H.; Robinson, R. [Los Alamos National Lab., NM (United States)

    1997-12-31

    The Manuel Lujan Jr. Neutron Scattering Center, Los Alamos National Laboratory is in need of a high field, split-pair, pulse magnet that would provide a 25--30 T field in a 25 mm bore and 10 mm split gap for 2--4 ms at a repetition rate of 2 Hz. Single stack Bitter magnets of this type providing less than 20 T vertical field in the split gap have been constructed before. To produce higher fields, there is a need to use a multiple layer coil with internal reinforcement. The magnet should withstand up to 10{sup 7} cycles of loading and unloading. The authors have conducted a feasibility study that address these unique requirements.

  15. Pulse-train control of photofragmentation at constant field energy

    DEFF Research Database (Denmark)

    Tiwari, Ashwani Kumar; Henriksen, Niels Engholm

    2014-01-01

    We consider a phaselocked two-pulse sequence applied to photofragmentation in the weak-field limit. The two pulses are not overlapping in time, i.e., the energy of the pulse-train is constant for all time delays. It is shown that the relative yield of excited Br* in the nonadiabatic process: I + Br......*←IBr → I + Br, changes as a function of time delay when the two excited wave packets interfere. The underlying mechanisms are analyzed and the change in the branching ratio as a function of time delay is only a reflection of a changing frequency distribution of the pulse train; the branching ratio does...

  16. Near-Field Magnetic Dipole Moment Analysis

    Science.gov (United States)

    Harris, Patrick K.

    2003-01-01

    This paper describes the data analysis technique used for magnetic testing at the NASA Goddard Space Flight Center (GSFC). Excellent results have been obtained using this technique to convert a spacecraft s measured magnetic field data into its respective magnetic dipole moment model. The model is most accurate with the earth s geomagnetic field cancelled in a spherical region bounded by the measurement magnetometers with a minimum radius large enough to enclose the magnetic source. Considerably enhanced spacecraft magnetic testing is offered by using this technique in conjunction with a computer-controlled magnetic field measurement system. Such a system, with real-time magnetic field display capabilities, has been incorporated into other existing magnetic measurement facilities and is also used at remote locations where transport to a magnetics test facility is impractical.

  17. Weibel magnetic field competes with Biermann fields in laser-solid interactions

    Science.gov (United States)

    Shukla, Nitin; Schoeffler, Kevin; Vieira, Jorge; Fonseca, Ricardo; Silva, Luis

    2016-10-01

    Biermann battery induced magnetic fields caused by non-parallel density and temperature gradients, first investigated experimentally, continue to be measured in many current experiments. A detailed study of Biermann generated magnetic fields in collisionless systems has been carried out, showing that for large system sizes (L /de >= 100) , where de is the electron inertial length, the Weibel instability dominates as the major source of magnetic field. In this work, we demonstrate the possibility of experimentally generating this strong Weibel magnetic field. We model, using ab initio PIC simulations, the interaction of a short (ps) high intensity (a0 >= 1) laser pulse, with a target of sufficiently large gradient scale length, L. The expanding hot energetic electron population generated by the laser produces an anisotropy in the velocity distribution. This anisotropy provides the free energy that drives the Weibel instability that appears on the surfaces of the target and dominates over the Biermann battery field.

  18. Magnetic Fields from the Electroweak Phase Transition

    CERN Document Server

    Törnkvist, O

    1998-01-01

    I review some of the mechanisms through which primordial magnetic fields may be created in the electroweak phase transition. I show that no magnetic fields are produced initially from two-bubble collisions in a first-order transition. The initial field produced in a three-bubble collision is computed. The evolution of fields at later times is discussed.

  19. Effect of solenoidal magnetic field on drifting laser plasma

    Science.gov (United States)

    Takahashi, Kazumasa; Okamura, Masahiro; Sekine, Megumi; Cushing, Eric; Jandovitz, Peter

    2013-04-01

    An ion source for accelerators requires to provide a stable waveform with a certain pulse length appropriate to the application. The pulse length of laser ion source is easy to control because it is expected to be proportional to plasma drifting distance. However, current density decay is proportional to the cube of the drifting distance, so large current loss will occur under unconfined drift. We investigated the stability and current decay of a Nd:YAG laser generated copper plasma confined by a solenoidal field using a Faraday cup to measure the current waveform. It was found that the plasma was unstable at certain magnetic field strengths, so a baffle was introduced to limit the plasma diameter at injection and improve the stability. Magnetic field, solenoid length, and plasma diameter were varied in order to find the conditions that minimize current decay and maximize stability.

  20. Zero quantum NMR imaging and spectroscopy in a low homogeneity magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hall, L.D.; Norwood, T.J.

    1987-10-27

    This patent describes a method of obtaining zero-quantum coherence resolved images and spectra from a spin system substance in an inhomogeneous or low homogeneity magnetic field which comprises applying to the substance a pulse and spatial encoding sequence.

  1. Deformation of Water by a Magnetic Field

    Science.gov (United States)

    Chen, Zijun; Dahlberg, E. Dan

    2011-01-01

    After the discovery that superconducting magnets could levitate diamagnetic objects, researchers became interested in measuring the repulsion of diamagnetic fluids in strong magnetic fields, which was given the name "The Moses Effect." Both for the levitation experiments and the quantitative studies on liquids, the large magnetic fields necessary…

  2. Exploring Magnetic Fields with a Compass

    Science.gov (United States)

    Lunk, Brandon; Beichner, Robert

    2011-01-01

    A compass is an excellent classroom tool for the exploration of magnetic fields. Any student can tell you that a compass is used to determine which direction is north, but when paired with some basic trigonometry, the compass can be used to actually measure the strength of the magnetic field due to a nearby magnet or current-carrying wire. In this…

  3. Biological Effect of Magnetic Field in Mice

    Institute of Scientific and Technical Information of China (English)

    Zhao-Wei ZENG

    2005-01-01

    Objective: To study the biological effect of magnetic field in mice bodies. Method: With a piece of permanent magnet embeded in mice bodies beside the femoral artery and vein to measure the electrophoretic velocity(um/s). Result: The magnetic field in mice bodies on the experiment group that the electrophoretic velocity is faster more than control and free group.Conclusion:The magnetic field in animal's body can raise the negative electric charges on the surface of erythrocyte to improve the microcirculation, this is the biological effect of magnetic field.

  4. The Magnetic Field Effect on Planetary Nebulae

    Institute of Scientific and Technical Information of China (English)

    A. R. Khesali; K. Kokabi

    2006-01-01

    In our previous work on the 3-dimensional dynamical structure of planetary nebulae the effect of magnetic field was not considered. Recently Jordan et al. have directly detected magnetic fields in the central stars of some planetary nebulae. This discovery supports the hypothesis that the non-spherical shape of most planetary nebulae is caused by magnetic fields in AGB stars. In this study we focus on the role of initially weak toroidal magnetic fields embedded in a stellar wind in altering the shape of the PN. We found that magnetic pressure is probably influential on the observed shape of most PNe.

  5. Pulsed field gel electrophoresis on frozen tumour tissue sections.

    OpenAIRE

    Boultwood, J; Kaklamanis, L.; Gatter, K C; Wainscoat, J S

    1992-01-01

    The application of pulsed field gel electrophoresis (PFGE) to the molecular genetic analysis of solid tumours has been restricted by the requirement for whole single cells as a DNA source. A simple technique which allows for the direct analysis of histologically characterised solid tumour material by pulsed field gel electrophoresis was developed. Single frozen tissue sections obtained from colonic carcinoma specimens were embedded without further manipulation in molten, low melting temperatu...

  6. Magnetic field concentrator for probing optical magnetic metamaterials.

    Science.gov (United States)

    Antosiewicz, Tomasz J; Wróbel, Piotr; Szoplik, Tomasz

    2010-12-06

    Development of all dielectric and plasmonic metamaterials with a tunable optical frequency magnetic response creates a need for new inspection techniques. We propose a method of measuring magnetic responses of such metamaterials within a wide range of optical frequencies with a single probe. A tapered fiber probe with a radially corrugated metal coating concentrates azimuthally polarized light in the near-field into a subwavelength spot the longitudinal magnetic field component which is much stronger than the perpendicular electric one. The active probe may be used in a future scanning near-field magnetic microscope for studies of magnetic responses of subwavelength elementary cells of metamaterials.

  7. Direct observation of f-pair magnetic field effects and time-dependence of radical pair composition using rapidly switched magnetic fields and time-resolved infrared methods.

    Science.gov (United States)

    Woodward, Jonathan R; Foster, Timothy J; Salaoru, Adrian T; Vink, Claire B

    2008-07-21

    A rapidly switched (magnetic field was employed to directly observe magnetic fields from f-pair reactions of radical pairs in homogeneous solution. Geminate radical pairs from the photoabstraction reaction of benzophenone from cyclohexanol were observed directly using a pump-probe pulsed magnetic field method to determine their existence time. No magnetic field effects from geminate pairs were observed at times greater than 100 ns after initial photoexcitation. By measuring magnetic field effects for fields applied continuously only after this initial geminate period, f-pair effects could be directly observed. Measurement of the time-dependence of the field effect for the photolysis of 2-hydroxy-4-(2-hydroxyethoxy)-2-methylpropiophenone in cyclohexanol using time-resolved infrared spectroscopy revealed not only the presence of f-pair magnetic field effects but also the ability of the time dependence of the MARY spectra to observe the changing composition of the randomly encountering pairs throughout the second order reaction period.

  8. Electric field induced needle-pulsed arc discharge carbon nanotube production apparatus: circuitry and mechanical design.

    Science.gov (United States)

    Kia, Kaveh Kazemi; Bonabi, Fahimeh

    2012-12-01

    A simple and low cost apparatus is reported to produce multiwall carbon nanotubes and carbon nano-onions by a low power short pulsed arc discharge reactor. The electric circuitry and the mechanical design details and a micro-filtering assembly are described. The pulsed-plasma is generated and applied between two graphite electrodes. The pulse width is 0.3 μs. A strong dc electric field is established along side the electrodes. The repetitive discharges occur in less than 1 mm distance between a sharp tip graphite rod as anode, and a tubular graphite as cathode. A hydrocarbon vapor, as carbon source, is introduced through the graphite nozzle in the cathode assembly. The pressure of the chamber is controlled by a vacuum pump. A magnetic field, perpendicular to the plasma path, is provided. The results show that the synergetic use of a pulsed-current and a dc power supply enables us to synthesize carbon nanoparticles with short pulsed plasma. The simplicity and inexpensiveness of this plan is noticeable. Pulsed nature of plasma provides some extra degrees of freedom that make the production more controllable. Effects of some design parameters such as electric field, pulse frequency, and cathode shape are discussed. The products are examined using scanning probe microscopy techniques.

  9. Electric field induced needle-pulsed arc discharge carbon nanotube production apparatus: Circuitry and mechanical design

    Science.gov (United States)

    Kia, Kaveh Kazemi; Bonabi, Fahimeh

    2012-12-01

    A simple and low cost apparatus is reported to produce multiwall carbon nanotubes and carbon nano-onions by a low power short pulsed arc discharge reactor. The electric circuitry and the mechanical design details and a micro-filtering assembly are described. The pulsed-plasma is generated and applied between two graphite electrodes. The pulse width is 0.3 μs. A strong dc electric field is established along side the electrodes. The repetitive discharges occur in less than 1 mm distance between a sharp tip graphite rod as anode, and a tubular graphite as cathode. A hydrocarbon vapor, as carbon source, is introduced through the graphite nozzle in the cathode assembly. The pressure of the chamber is controlled by a vacuum pump. A magnetic field, perpendicular to the plasma path, is provided. The results show that the synergetic use of a pulsed-current and a dc power supply enables us to synthesize carbon nanoparticles with short pulsed plasma. The simplicity and inexpensiveness of this plan is noticeable. Pulsed nature of plasma provides some extra degrees of freedom that make the production more controllable. Effects of some design parameters such as electric field, pulse frequency, and cathode shape are discussed. The products are examined using scanning probe microscopy techniques.

  10. Spin state ordering of strongly correlating LaCoO3 induced at ultrahigh magnetic fields

    Science.gov (United States)

    Ikeda, Akihiko; Nomura, Toshihiro; Matsuda, Yasuhiro H.; Matsuo, Akira; Kindo, Koichi; Sato, Keisuke

    2016-06-01

    Magnetization measurements of LaCoO3 have been carried out up to 133 T, generated with a destructive pulse magnet at a wide temperature range from 2 to 120 K. A novel magnetic transition was found at B >100 T and T >T*=32 ±5 K, which is characterized by its transition field increasing with increasing temperature. At T LaCoO3 at high magnetic fields.

  11. In vitro exposure of human chondrocytes to pulsed electromagnetic fields

    Directory of Open Access Journals (Sweden)

    V Nicolin

    2009-08-01

    Full Text Available The effect of pulsed electromagnetic fields (PEMFs on the proliferation and survival of matrix-induced autologous chondrocyte implantation (MACI®-derived cells was studied to ascertain the healing potential of PEMFs. MACI-derived cells were taken from cartilage biopsies 6 months after surgery and cultured. No dedifferentiation towards the fibroblastic phenotype occurred, indicating the success of the surgical implantation. The MACI-derived cultured chondrocytes were exposed to 12 h/day (short term or 4 h/day (long term PEMFs exposure (magnetic field intensity, 2 mT; frequency, 75 Hz and proliferation rate determined by flow cytometric analysis. The PEMFs exposure elicited a significant increase of cell number in the SG2M cell cycle phase. Moreover, cells isolated from MACI® scaffolds showed the presence of collagen type II, a typical marker of chondrocyte functionality. The results show that MACI® membranes represent an optimal bioengineering device to support chondrocyte growth and proliferation in surgical implants. The surgical implant of MACI® combined with physiotherapy is suggested as a promising approach for a faster and safer treatment of cartilage traumatic lesions.

  12. Nonlinear interaction of charged particles with strong laser pulses in a magnetic undulator

    Directory of Open Access Journals (Sweden)

    H. K. Avetissian

    2010-08-01

    Full Text Available Laser acceleration due to the nonlinear-threshold phenomena of charged particle “reflection” and capture by slowed wave in a magnetic undulator is considered. The obtained numerical results prove the particle reflection and capture phenomena in the field of actual laser pulses with temporal and space profiles which lead to the particles acceleration. In contrast to the reflection regime where particle acceleration takes place already at the constant undulator step, in the capture regime it is necessary to increase adiabatically the undulator step along the laser pulse propagation direction by the certain self-consistent variation law corresponding to acceleration rate.

  13. Electrolytic tiltmeters inside magnetic fields: Some observations

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, J. [CIEMAT, Madrid (Spain); Arce, P. [CIEMAT, Madrid (Spain); Barcala, J.M. [CIEMAT, Madrid (Spain); Calvo, E. [CIEMAT, Madrid (Spain); Ferrando, A. [CIEMAT, Madrid (Spain)]. E-mail: antonio.ferrando@ciemat.es; Josa, M.I. [CIEMAT, Madrid (Spain); Luque, J.M. [CIEMAT, Madrid (Spain); Molinero, A. [CIEMAT, Madrid (Spain); Navarrete, J. [CIEMAT, Madrid (Spain); Oller, J.C. [CIEMAT, Madrid (Spain); Yuste, C. [CIEMAT, Madrid (Spain); Calderon, A. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Garcia-Moral, L.A. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Gomez, G. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Gonzalez-Sanchez, F.J. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Martinez-Rivero, C. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Matorras, F. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Rodrigo, T. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Ruiz-Arbol, P. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Scodellaro, L. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Sobron, M. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Vila, I. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Virto, A.L. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain)

    2007-04-21

    We present observations of the electrolytic clinometers behaviour inside magnetic field environments introducing phenomenological expressions to account for the measured output voltage variations as functions of field gradients and field strengths.

  14. Pulsed Magnetic Welding for Advanced Core and Cladding Steel

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Guoping [Univ. of Wisconsin, Madison, WI (United States); Yang, Yong [Univ. of Florida, Gainesville, FL (United States)

    2013-12-19

    To investigate a solid-state joining method, pulsed magnetic welding (PMW), for welding the advanced core and cladding steels to be used in Generation IV systems, with a specific application for fuel pin end-plug welding. As another alternative solid state welding technique, pulsed magnetic welding (PMW) has not been extensively explored on the advanced steels. The resultant weld can be free from microstructure defects (pores, non-metallic inclusions, segregation of alloying elements). More specifically, the following objectives are to be achieved: 1. To design a suitable welding apparatus fixture, and optimize welding parameters for repeatable and acceptable joining of the fuel pin end-plug. The welding will be evaluated using tensile tests for lap joint weldments and helium leak tests for the fuel pin end-plug; 2 Investigate the microstructural and mechanical properties changes in PMW weldments of proposed advanced core and cladding alloys; 3. Simulate the irradiation effects on the PWM weldments using ion irradiation.

  15. From Inverse to Delayed Magnetic Catalysis in Strong Magnetic Field

    CERN Document Server

    Mao, Shijun

    2016-01-01

    We study magnetic field effect on chiral phase transition in a Nambu--Jona-Lasinio model. In comparison with mean field approximation containing quarks only, including mesons as quantum fluctuations in the model leads to a transition from inverse to delayed magnetic catalysis at finite temperature and delays the transition at finite baryon chemical potential. The location of the critical end point depends on the the magnetic field non-monotonously.

  16. Collimation of laser-produced plasmas using axial magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Amitava; Harilal, Sivanandan S.; Hassan, Syed M.; Endo, Akira; Mocek, Tomas; Hassanein, A.

    2015-06-01

    We investigated the expansion dynamics of laser-produced plasmas expanding into an axial magnetic field. Plasmas were generated by focusing 1.064 µm Nd:YAG laser pulses onto a planar tin target in vacuum and allowed to expand into a 0.5 T magnetic-filed where field lines were aligned along the plume expansion direction. Gated images employing intensified CCD showed focusing of the plasma plume, which were also compared with results obtained using particle-in-cell modelling methods. The estimated density and temperature of the plasma plumes employing emission spectroscopy revealed significant changes in the presence and absence of the 0.5T magnetic field. In the presence of the field, the electron temperature is increased with distance from the target, while the density showed opposite effects.

  17. Detection of secular acceleration pulses from magnetic observatory data

    Science.gov (United States)

    Soloviev, Anatoly; Chulliat, Arnaud; Bogoutdinov, Shamil

    2017-09-01

    Geomagnetic secular variation (SV) models for the epochs before the space era are based on magnetic observatory data, which represent relatively rough and noisy time series due to magnetic storms, anthropogenic spikes and gaps. These models are often strongly regularized in time, so that fast variations in the SV are smoothed out. However, recent studies show that at least some of the geomagnetic jerks observed at the Earth's surface emanate from increasing and decreasing phases of secular acceleration (SA) pulses at the core surface. The latter ones are direct manifestation of the dynamic processes taking place in the liquid core. They were first detected from satellite data, which are both of higher quality and more homogeneous in terms of geographical coverage than ground data. Herein we attempt to carry out similar studies based on observatory data available for a longer period. The proposed method of SV modeling and recognition of SA pulses relies on a new technique of processing time series based on fuzzy mathematics. Comparison with the SV modeling results derived from satellite data shows their high conformity with the proposed method. Stability and reliability of the SA pulse recognition are demonstrated by the examples of well-studied SA pulses in 2006, 2009 and 2012. Moreover, several new SA pulses around 1996, 1999, 2002 and 2014 are discovered as a result of the new approach application to multi-observatory data analysis. The latter provides a basis for applying the method to older historical data and investigate SA pulses and geomagnetic jerks further back in time.

  18. Dynamic shielding of the magnetic fields

    Directory of Open Access Journals (Sweden)

    RAU, M.

    2010-11-01

    Full Text Available The paper presents a comparative study of the methods used to control and compensate the direct and alternative magnetic fields. Two frequently used methods in the electromagnetic compatibility of the complex biomagnetism installations were analyzed. The two methods refer to the use of inductive magnetic field sensors (only for alternative fields and of fluxgate magnetometers as active transducers which measures both the direct and alternative components of the magnetic field. The applications of the dynamic control of the magnetic field are: control of the magnetic field of the military ships, control of parasite magnetic field produced by power transformers and the electrical networks, protection of the mass spectrometers, electronic microscopes, SQUID and optical pumping magnetometers for applications in biomagnetism.

  19. Field free line magnetic particle imaging

    CERN Document Server

    Erbe, Marlitt

    2014-01-01

    Marlitt Erbe provides a detailed introduction into the young research field of Magnetic Particle Imaging (MPI) and field free line (FFL) imaging in particular. She derives a mathematical description of magnetic field generation for FFL imaging in MPI. To substantiate the simulation studies on magnetic FFL generation with a proof-of-concept, the author introduces the FFL field demonstrator, which provides the world's first experimentally generated rotated and translated magnetic FFL field complying with the requirements for FFL reconstruction. Furthermore, she proposes a scanner design of consi

  20. MAGNETIC PULSED PROCESSING OF METALS FOR ADVANCED TECHNOLOGIES OF MODERNITY – A BRIEF REVIEW

    Directory of Open Access Journals (Sweden)

    Yu. V. Batygin

    2016-11-01

    Full Text Available The aim of the article is dedicated to the brief review of the main achievements of the advanced technologies with usage of the energy of the pulsed magnetic fields. Originality. The new suggestions are represented. They are based on the results of development of the new scientific direction in area of the magnetic pulsed processing of thin-walled sheet metals when a penetration of the acting fields is quite significant. The known traditional approaches based on the skin-effect in electrodynamics and were successfully implemented. Methodology of the analysis consist of careful theoretical and practical experiments review and its future development. Results of the research based on the existing experimental approbation were presented visually with the description followed The known approaches to solution actual production problems based on the skin-effect in electrodynamics are described. Practical value. The first of practical propositions is related to stamping of the drawing the printed circuit boards on the cooper foil with thickness about ~50 mkm. This operation is realizing by the forces of magnetic pressure directly without any supplements introduction. The second consists in usage the magnetic pulsed attraction for external removing the dents in the car body. This operation does not demand disassembling of elemental base and allows preserving the paint of coverings. Both of these technologies could to minimize the working time, to decries the volume of the waste products and to make the manufacturing existed much cheaper.

  1. High-Field Magnetization of the Pyrochlore Compound Gd2Ti2O7

    Science.gov (United States)

    Narumi, Yasuo; Kikkawa, Akiko; Katsumata, Koichi; Honda, Zentaro; Hagiwara, Masayuki; Kindo, Koichi

    2006-09-01

    High-field magnetization measurements have been preformed on a single crystal sample of the pyrochlore compound Gd2Ti2O7 using a pulse magnet in conjunction with a dilution refrigerator. The magnetization curve at 0.3 K reveals two magnetic phase transitions when the magnetic field is applied along b [111]. At temperatures slightly above TN, a magnetization plateau appears around 5 T and the magnetization increases again from about 15 T with a convex curvature. It is considered that this crossover is due to a competition among thermal fluctuations, short-range antiferromagnetic ordering and geometrical frustration.

  2. Pulse Design in Solid-State Nuclear Magnetic Resonance

    DEFF Research Database (Denmark)

    Palani, Ravi Shankar

    2017-01-01

    The work presented in this dissertation is centred on the theory of experimental methods in solid-state Nuclear Magnetic Resonance (NMR) spectroscopy, which deals with interaction of electromagnetic radiation with nuclei in a magnetic field and possessing a fundamental quantum mechanical property...

  3. Parahydrogen-induced polarization at zero magnetic field.

    Science.gov (United States)

    Butler, Mark C; Kervern, Gwendal; Theis, Thomas; Ledbetter, Micah P; Ganssle, Paul J; Blanchard, John W; Budker, Dmitry; Pines, Alexander

    2013-06-21

    We use symmetry arguments and simple model systems to describe the conversion of the singlet state of parahydrogen into an oscillating sample magnetization at zero magnetic field. During an initial period of free evolution governed by the scalar-coupling Hamiltonian HJ, the singlet state is converted into scalar spin order involving spins throughout the molecule. A short dc pulse along the z axis rotates the transverse spin components of nuclear species I and S through different angles, converting a portion of the scalar order into vector order. The development of vector order can be described analytically by means of single-transition operators, and it is found to be maximal when the transverse components of I are rotated by an angle of ±π∕2 relative to those of S. A period of free evolution follows the pulse, during which the vector order evolves as a set of oscillating coherences. The imaginary parts of the coherences represent spin order that is not directly detectable, while the real parts can be identified with oscillations in the z component of the molecular spin dipole. The dipole oscillations are due to a periodic exchange between Iz and Sz, which have different gyromagnetic ratios. The frequency components of the resulting spectrum are imaginary, since the pulse cannot directly induce magnetization in the sample; it is only during the evolution under HJ that the vector order present at the end of the pulse evolves into detectable magnetization.

  4. Parahydrogen-induced polarization at zero magnetic field

    Science.gov (United States)

    Butler, Mark C.; Kervern, Gwendal; Theis, Thomas; Ledbetter, Micah P.; Ganssle, Paul J.; Blanchard, John W.; Budker, Dmitry; Pines, Alexander

    2013-06-01

    We use symmetry arguments and simple model systems to describe the conversion of the singlet state of parahydrogen into an oscillating sample magnetization at zero magnetic field. During an initial period of free evolution governed by the scalar-coupling Hamiltonian HJ, the singlet state is converted into scalar spin order involving spins throughout the molecule. A short dc pulse along the z axis rotates the transverse spin components of nuclear species I and S through different angles, converting a portion of the scalar order into vector order. The development of vector order can be described analytically by means of single-transition operators, and it is found to be maximal when the transverse components of I are rotated by an angle of ±π/2 relative to those of S. A period of free evolution follows the pulse, during which the vector order evolves as a set of oscillating coherences. The imaginary parts of the coherences represent spin order that is not directly detectable, while the real parts can be identified with oscillations in the z component of the molecular spin dipole. The dipole oscillations are due to a periodic exchange between Iz and Sz, which have different gyromagnetic ratios. The frequency components of the resulting spectrum are imaginary, since the pulse cannot directly induce magnetization in the sample; it is only during the evolution under HJ that the vector order present at the end of the pulse evolves into detectable magnetization.

  5. Magnetic reconnection in high-energy-density plasmas in the presence of an external magnetic field

    Science.gov (United States)

    Fox, W.; Bhattacharjee, A.; Fiksel, G.; Nilson, P.; Hu, S.; Chang, P.-Y.; Barnak, D.; Betti, R.

    2012-10-01

    Magnetic reconnection has recently been observed and studied in high-energy-density, laser-produced plasmas. These experiments are interesting both for obtaining fundamental data on reconnection, and may also be relevant for inertial fusion, as this magnetic reconnection geometry, with multiple, colliding, magnetized plasma bubbles, occurs naturally inside ICF hohlraums. We present initial results of experiments conducted on the OMEGA EP facility on magnetic reconnection between colliding, magnetized blowoff plasmas. While in previous experiments the magnetic fields were self-generated in the plasma by the Biermann battery effect, in these experiments the seed magnetic field is generated by pulsing current through a pair of external foils using the MIFEDS current generator (Magneto-Inertial Fusion Electrical Discharge System) developed at LLE. Time-resolved images of the magnetic fields and plasma dynamics are obtained from proton radiography and x-ray self-emission, respectively. We present initial results of the experiments, including comparison to ``null'' experiments with zero MIFEDS magnetic field, and associated modeling using the radiation-hydro code DRACO and the particle-in-cell code PSC.

  6. Unidirectional optical pulse propagation equation for materials with both electric and magnetic responses

    Science.gov (United States)

    Kinsler, Paul

    2010-02-01

    I derive unidirectional wave equations for fields propagating in materials with both electric and magnetic dispersion and nonlinearity. The derivation imposes no conditions on the pulse profile except that the material modulates the propagation slowly, that is, that loss, dispersion, and nonlinearity have only a small effect over the scale of a wavelength. It also allows a direct term-to-term comparison of the exact bidirectional theory with its approximate unidirectional counterpart.

  7. Energy confinement and magnetic field generation in the SSPX spheromak

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, B; McLean, H S; Wood, R D; Hooper, E B; Hill, D N; Jayakumar, J; Moller, J; Romero-Talamas, C; Casper, T A; LoDestro, L L; Pearlstein, L D; Johnson, III, J A; Mezonlin, E

    2008-02-11

    The Sustained Spheromak Physics Experiment (SSPX) [E.B. Hooper, et. al., Nuclear Fusion, Vol. 39, No. 7] explores the physics of efficient magnetic field buildup and energy confinement, both essential parts of advancing the spheromak concept. Extending the spheromak formation phase increases the efficiency of magnetic field generation with the maximum edge magnetic field for a given injector current (B/I) from 0.65 T/MA previously to 0.9 T/MA. We have achieved the highest electron temperatures (T{sub e}) recorded for a spheromak with T{sub e} > 500 eV, toroidal magnetic field {approx}1 T and toroidal current ({approx}1 MA) [R.D. Wood, D.N. Hill, H.S. McLean, E.B. Hooper, B.F. Hudson, J.M. Moller, 'Improved magnetic field generation efficiency and higher temperature spheromak plasmas', submitted to Physical Review Letters]. Extending the sustainment phase to > 8 ms extends the period of low magnetic fluctuations (< 1 %) by 50%. The NIMROD 3-D resistive MHD code [C.R. Sovinec, T.A. Gianakon, E.D. Held, S.E. Kruger and D.D. Schnack, The NIMROD Team, Phys. Plasmas 10, 1727 (2003)] reproduces the observed flux amplification {Psi}{sub pol}/{Psi}{sub gun}. Successive gun pulses are demonstrated to maintain the magnetic field in a quasi-steady state against resistive decay. Initial measurements of neutral particle flux in multi-pulse operation show charge-exchange power loss < 1% of gun input power and dominantly collisional majority ion heating. The evolution of electron temperature shows a distinct and robust feature of spheromak formation: a hollow-to-peaked T{sub e}(r) associated with q {approx} 1/2.

  8. Magnetic field mapper based on rotating coils

    CERN Document Server

    AUTHOR|(CDS)2087244; Arpaia, Pasquale

    This thesis presents a magnetic field mapper based on rotating coils. The requirements, the architecture, the conceptual design, and the prototype for straight magnets were shown. The proposed system is made up of a rotating coil transducer and a train-like system for longitudinal motion and positioning inside magnet bore. The mapper allows a localized measurement of magnetic fields and the variation of the harmonic multipole content in the magnet ends. The proof-of-principle demonstration and the experimental characterization of the rotating-coil transducer specifically conceived for mapping validated the main objective of satisfying the magnetic measurement needs of the next generation of compact accelerators.

  9. Magnetic Fields and Star Formation

    CERN Document Server

    Van Loo, S; Falle, S A E G

    2012-01-01

    Research performed in the 1950s and 1960s by Leon Mestel on the roles of magnetic fields in star formation established the framework within which he and other key figures have conducted subsequent investigations on the subject. This short tribute to Leon contains a brief summary of some, but not all, of his ground breaking contributions in the area. It also mentions of some of the relevant problems that have received attention in the last few years. The coverage is not comprehensive, and the authors have drawn on their own results more and touched more briefly on those of others than they would in a normal review. Theirs is a personal contribution to the issue honouring Leon, one of the truly great gentlemen, wits, and most insightful of astrophysicists.

  10. Development of advanced radiation monitors for pulsed neutron fields

    CERN Document Server

    AUTHOR|(CDS)2081895

    The need of radiation detectors capable of efficiently measuring in pulsed neutron fields is attracting widespread interest since the 60s. The efforts of the scientific community substantially increased in the last decade due to the increasing number of applications in which this radiation field is encountered. This is a major issue especially at particle accelerator facilities, where pulsed neutron fields are present because of beam losses at targets, collimators and beam dumps, and where the correct assessment of the intensity of the neutron fields is fundamental for radiation protection monitoring. LUPIN is a neutron detector that combines an innovative acquisition electronics based on logarithmic amplification of the collected current signal and a special technique used to derive the total number of detected neutron interactions, which has been specifically conceived to work in pulsed neutron fields. Due to its special working principle, it is capable of overcoming the typical saturation issues encountere...

  11. DC-based magnetic field controller

    Energy Technology Data Exchange (ETDEWEB)

    Kotter, Dale K. (Shelley, ID); Rankin, Richard A. (Ammon, ID); Morgan, John P,. (Idaho Falls, ID)

    1994-01-01

    A magnetic field controller for laboratory devices and in particular to dc operated magnetic field controllers for mass spectrometers, comprising a dc power supply in combination with improvements to a hall probe subsystem, display subsystem, preamplifier, field control subsystem, and an output stage.

  12. DC-based magnetic field controller

    Energy Technology Data Exchange (ETDEWEB)

    Kotter, D.K.; Rankin, R.A.; Morgan, J.P.

    1994-05-31

    A magnetic field controller is described for laboratory devices and in particular to dc operated magnetic field controllers for mass spectrometers, comprising a dc power supply in combination with improvements to a Hall probe subsystem, display subsystem, preamplifier, field control subsystem, and an output stage. 1 fig.

  13. Magnetic field evolution in tidal disruption events

    CERN Document Server

    Bonnerot, Clément; Lodato, Giuseppe; Rossi, Elena M

    2016-01-01

    When a star gets tidally disrupted by a supermassive black hole, its magnetic field is expected to be transmitted to the debris. In this paper, we study this process via smoothed particle magnetohydrodynamical simulations of the disruption and early debris evolution including the stellar magnetic field. As the gas stretches into a stream, we show that the magnetic field evolution is strongly dependent on its orientation with respect to the stretching direction. In particular, an alignment of the field lines with the direction of stretching induces an increase of the magnetic energy. For disruptions happening well within the tidal radius, the star compression causes the magnetic field strength to sharply increase by an order of magnitude at the time of pericentre passage. If the disruption is partial, we find evidence for a dynamo process occurring inside the surviving core due to the formation of vortices. This causes an amplification of the magnetic field strength by a factor of $\\sim 10$. However, this valu...

  14. Demagnetizing fields in active magnetic regenerators

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein; Bahl, Christian R.H.; Smith, Anders

    2014-01-01

    is in general both a function of the overall shape of the regenerator and its morphology (packed particles, parallel plates etc.) as well as the magnetization of the material. Due to the pronounced temperature dependence of the magnetization near the Curie temperature, the demagnetization field is also......A magnetic material in an externally applied magnetic field will in general experience a spatially varying internal magnetic field due to demagnetizing effects. When the performance of active magnetic regenerators (AMRs) is evaluated using numerical models the internal field is often assumed...... temperature dependent. We propose a relatively straightforward method to correct sufficiently for the demagnetizing field in AMR models. We discuss how the demagnetizing field behaves in regenerators made of packed spheres under realistic operation conditions....

  15. New knowledge of the Galactic magnetic fields

    CERN Document Server

    Han, J L

    2009-01-01

    The magnetic fields of our Milky Way galaxy are the main agent for cosmic rays to transport. In the last decade, much new knowledge has been gained from measurements of the Galactic magnetic fields. In the Galactic disk, from the RMs of a large number of newly discovered pulsars, the large-scale magnetic fields along the spiral arms have been delineated in a much larger region than ever before, with alternating directions in the arm and interarm regions. The toroidal fields in the Galactic halo were revealed to have opposite directions below and above the Galactic plane, which is an indication of an A0 mode dynamo operating in the halo. The strength of large-scale fields obtained from pulsar RM data has been found to increase exponentially towards the Galactic center. Compared to the steep Kolmogorov spectrum of magnetic energy at small scales, the large-scale magnetic fields show a shallow broken spatial magnetic energy spectrum.

  16. Behaviour of ferrocholesterics under external magnetic fields

    Science.gov (United States)

    Petrescu, Emil; Motoc, Cornelia

    2001-08-01

    The influence of an external magnetic field on the orientational behaviour of a ferrocholesteric with a positive magnetic anisotropy is investigated. Both the phenomena arising when the field was switched on or switched off are considered. It is found that the field needed for a ferrocholesteric-ferronematic transition BFC↑ is higher when compared to that obtained for the pure cholesteric ( BC↑). A similar result was obtained when estimating the critical field for the homeotropic ferronematic-ferrocholesteric (focal conic) transition, occurring when the magnetic field was decreased or switched off. We found that BFC↓> BC↓. These results are explained when considering that the magnetic moments of the magnetic powder are not oriented parallel to the liquid crystal molecular directors, therefore hindering their orientation under a magnetic field.

  17. Coulomb crystals in the magnetic field

    CERN Document Server

    Baiko, D A

    2009-01-01

    The body-centered cubic Coulomb crystal of ions in the presence of a uniform magnetic field is studied using the rigid electron background approximation. The phonon mode spectra are calculated for a wide range of magnetic field strengths and for several orientations of the field in the crystal. The phonon spectra are used to calculate the phonon contribution to the crystal energy, entropy, specific heat, Debye-Waller factor of ions, and the rms ion displacements from the lattice nodes for a broad range of densities, temperatures, chemical compositions, and magnetic fields. Strong magnetic field dramatically alters the properties of quantum crystals. The phonon specific heat increases by many orders of magnitude. The ion displacements from their equilibrium positions become strongly anisotropic. The results can be relevant for dusty plasmas, ion plasmas in Penning traps, and especially for the crust of magnetars (neutron stars with superstrong magnetic fields $B \\gtrsim 10^{14}$ G). The effect of the magnetic ...

  18. Trapped field characteristics on {phi}65 mm GdBaCuO bulk by modified multi-pulse technique with stepwise cooling (MMPSC)

    Energy Technology Data Exchange (ETDEWEB)

    Fujishiro, H. [Faculty of Engineering, Iwate University, 3-4-5 Ueda, Morioka, Iwate 020-8551 (Japan)], E-mail: fujishiro@iwate-u.ac.jp; Tateiwa, T.; Kakehata, K.; Hiyama, T.; Naito, T. [Faculty of Engineering, Iwate University, 3-4-5 Ueda, Morioka, Iwate 020-8551 (Japan); Yanagi, Y. [IMRA Material R and D Co., Ltd., 5-50 Hachiken-cho, Kariya 448-0021 (Japan)

    2008-09-15

    A large GdBaCuO superconducting bulk 65 mm in diameter has been magnetized by a two-stage pulse field magnetization method named as a modified multi-pulse technique with stepwise cooling (MMPSC). The trapped field B{sub T}{sup P} of 3.0 T was achieved at the bulk center at 40 K by optimizing the trapped field profile at the first stage of the MMPSC method, on which the maximum B{sub T}{sup P} was as low as 1.9 T at 40 K for the single pulsed field application. A magnetic gradient along the radius direction larger than that estimated by a Bean's model is realized at the ascending stage of the magnetic pulse field at the second stage, and a large amount of magnetic fluxes staying at the bulk periphery flow to the bulk center at the descending stage.

  19. Generating the optimal magnetic field for magnetic refrigeration

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Insinga, Andrea Roberto; Smith, Anders

    2016-01-01

    remanence distribution for any desired magnetic field. The method is based on the reciprocity theorem, which through the use of virtual magnets can be used to calculate the optimal remanence distribution. Furthermore, we present a method for segmenting a given magnet design that always results...

  20. Magnetostrictive hypersound generation by spiral magnets in the vicinity of magnetic field induced phase transition

    Science.gov (United States)

    Bychkov, Igor V.; Kuzmin, Dmitry A.; Kamantsev, Alexander P.; Koledov, Victor V.; Shavrov, Vladimir G.

    2016-11-01

    In present work we have investigated magnetostrictive ultrasound generation by spiral magnets in the vicinity of magnetic field induced phase transition from spiral to collinear state. We found that such magnets may generate transverse sound waves with the wavelength equal to the spiral period. We have examined two types of spiral magnetic structures: with inhomogeneous exchange and Dzyaloshinskii-Moriya interactions. Frequency of the waves from exchange-caused spiral magnetic structure may reach some THz, while in case of Dzyaloshinskii-Moriya interaction-caused spiral it may reach some GHz. These waves will be emitted like a sound pulses. Amplitude of the waves is strictly depends on the phase transition speed. Some aspects of microwaves to hypersound transformation by spiral magnets in the vicinity of phase transition have been investigated as well. Results of the work may be interesting for investigation of phase transition kinetics as well, as for various hypersound applications.