WorldWideScience

Sample records for pulse-spray pharmacomechanical thrombolysis

  1. Local Intraarterial Thrombolysis: In Vitro Comparison Between Automatic and Manual Pulse-Spray Infusion

    International Nuclear Information System (INIS)

    Froelich, Jens J.; Freymann, Christina; Hoppe, Martin; Thiel, Thomas; Wagner, H. Joachim; Barth, Klemens H.; Klose, Klaus J.

    1996-01-01

    Purpose: Manual and automatic pulse-spray infusion techniques are compared in vitro to evaluate the efficacy of thrombolysis and the distribution of urokinase and saline solution within thrombus using a pulse-spray catheter. Methods: A pulse-spray catheter was introduced into a human thrombus within a stenotic flow model. Automatic and manual pulsed infusion of urokinase and automatic pulsed infusion of saline solution were compared. To quantify the efficacy of thrombolysis, pressure gradients were recorded proximal and distal to the thrombus and during the course of infusion. Distribution of infused urokinase was assessed radiographically. Results: The fastest and most homogeneous dissolution of the thrombus was achieved with automatic pulsed infusion of urokinase, shown by decreasing transthrombotic pressure gradients (p < 0.001, Wilcoxon, matched pairs). Manual pulsed infusion of urokinase or saline solution resulted in inhomogeneous thrombus dissolution and delayed thrombolysis. Conclusion: Application of automatic pulse-spray injectors seems beneficial for more effective and homogeneous intraarterial pulse-spray thrombolysis when compared with conventional manual pulsed technique

  2. Isolated pharmacomechanical thrombolysis using the Trellis system

    LENUS (Irish Health Repository)

    O’Sullivan, GJ

    2010-01-01

    While anticoagulation remains the current gold standard for treating acute deep vein thrombosis,1 there is a growing body of evidence that rapid thrombus removal results in better short- and long-term outcomes.2–5 This is a practical guide to achieve rapid thrombus removal with isolated pharmacomechanical thrombolysis using the Trellis® peripheral infusion system.\\r\

  3. Venous function after pharmacomechanical thrombolysis for extensive iliofemoral deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Wim Greeff

    2017-08-01

    Full Text Available Background: Chronic venous insufficiency is an important complication following iliofemoral deep venous thrombosis. Early thrombus removal may preserve venous function and prevent this complication. This study represents the largest reported South African series of pharmacomechanical thrombolysis for iliofemoral deep venous thrombosis to date. Objective: To evaluate the long-term outcome following pharmacomechanical thrombolysis for proximal and extensive deep venous thrombosis in a private, specialist vascular unit. Methods: All patients who underwent pharmacomechanical thrombolysis for iliofemoral deep venous thrombosis between August 2009 and January 2016 were invited to return for clinical assessment and venous ultrasound. Clinical findings were recorded according to the Villalta score and clinical, etiology, anatomic and pathology (CEAP classification. The quality of life (QoL was assessed utilising the VEINES-QoL/Sym questionnaire, providing two scores per patient, one describing the QoL and the other symptom severity (Sym. Results: Thirty two patients (35 legs were evaluated. There were 25 females and 7 males, with a mean age of 33.5 years (±14 years. The mean follow-up period was 31 months (range 3 months – 80 months. Results of the CEAP classification were C0 = 24 (75%, C1 = 1 (4%, C2 = 2 (6%, C3 = 2 (6% and C4 = 3 (9%. Thirty-one (97% patients had Villalta scores from 0 to 4, indicating no or mild evidence of venous disease. One patient (3% had a Villalta score of 6, indicating post-thrombotic syndrome. The mean QoL score was 87% (±12 and the mean Sym score was 86% (±14. Twenty-four (75% patients had no abnormality on ultrasound, with fibrosis the most observed abnormality. Conclusion: Most patients who had undergone pharmacomechanical thrombolysis for extensive iliofemoral deep venous thrombosis showed few significant clinical signs of chronic venous insufficiency, had excellent function on venous ultrasound and reported

  4. Interventional recanalization of artificial arteriovenous fistula and graft for hemodialysis: angioplasty and pulsed-spray thrombolysis with Urokinase

    International Nuclear Information System (INIS)

    Shin, Sung Wook; Do, Young Soo; Park, Hong Seok and others

    1998-01-01

    To evaluate the effectiveness of percutaneous transluminal angioplasty (PTA) and pul-sed-spray pharmaco-mechanical thrombolysis (PSPMT) using urokinase for the management of insufficient hemodialysis access. Between September 1996 and May 1998, 21 insufficient hemodialysis accesses were treated in 16 patients(3 artificial arteriovenous fistulae, AVF; and 13 arteriovenous graft, AVG). PTA and PSPMT were performed in 6 and 15 cases, respectively, and success and long-term patency rates were evaluated. The overall success rate of PTA and PSPMT for insufficient hemodialysis access was 76. 2%(16/21). The success rates of PTA and PSPMT were 83.3%(5/6) and 73.3%(11/15), respectively. The primary patency rates of PSPMT were 69±12.8% at 6 months and 38±18.6% at 12 months. One of the two initially successful PTAs had been patent for 7 months, and the second PTA was performed at that time due to venous stenosis. The other was patent for 15 months throughout the follow-up period. PTA and PSPMT are effective primary methods for the treatment of insufficient hemodialysis access;success and patency rates were high, and the procedures can be performed repeatedly.=20

  5. The modified pulse-spray method using Urokinase in subacute and chronic thrombotic arterial occlusion

    International Nuclear Information System (INIS)

    Kim, Youn Kil; Hahn, Seong Tae; Baek, Jee Hee; Kim, Choon Yul; Shinn, Kyung Sub

    1996-01-01

    To evaluate the effectiveness and safety of the modified pulse-spray method using Urokinase(UK) in subacute and chronic thrombotic arterial occlusion. Modified pulse-spray methods using UK were performed in seven patients with subacute (1 week-1month) to chronic (1month-5years) occlusive symptoms such as limb pain, claudication and impotence. Angiographic examination revealed thrombotic occlusion of the aorta, common iliac arteries, brachial arterio-venous hemodialysis graft and femoro-popliteal bypass graft. The patients underwent thrombolysis using modified pulse-spray and additional constant infusion of UK. In the presence of underlying stenosis or organized clots, balloon angioplasty or stent placement was performed. Complete lysis was obtained in five of seven patients. For initial lysis, the mean dose of UK was 420,000 units, and the mean modified pulse-spray time was 50 minutes. Mean total dose of UK and mean total time for complete lysis were 800,000 units and 161 minutes, respectively. Thrombolysis of the femoro-popliteal bypass graft failed due to severe occlusion of the distal anastomosis. Partial lysis was achieved in one patient with aorto-illac occlusion, but further thrombolysis was stopped due to bleeding at the puncture site. The modified pulse-spray method using UK is effective in treating subacute and chronic arterial thrombotic occlusion. It augments the speed, safety and efficacy of thrombolysis. When underlying stenosis or organized clots remain after thrombolysis, ballon angioplasty or stent placement would be helpful

  6. Comparative Efficacy of Pulse-Spray Thrombolysis and Angioplasty Versus Surgical Salvage Procedures for Treatment of Recurrent Occlusion of PTFE Dialysis Access Grafts

    International Nuclear Information System (INIS)

    Polak, Joseph F.; Berger, Markus F.; Pagan-Marin, Heriberto; Aruny, John E.; Meyerovitz, Michael F.

    1998-01-01

    Purpose: To compare the efficacy of surgery versus pulse-spray thrombolysis and angioplasty in patients with recurrent thrombosis of polytetrafluoroethylene (PTFE) dialysis access grafts. Methods: We analyzed 96 consecutive interventions for thrombosed PTFE dialysis access grafts in 18 patients. Primary patency after thrombolysis and angioplasty (n= 25) was compared with primary patency following thrombectomy alone (n= 50) or thrombectomy followed by graft revision (n= 21) using life-table analysis. A Cox proportional hazards model that accounted for graft age and number of previous interventions was used to generate the relative risk for recurrent occlusion following therapy. Results: Life-table analysis showed that patency after thrombolysis and angioplasty was greater than that following thrombectomy alone (p= 0.02). After accounting for the age of the graft and the number of previous interventions (average six per patient), the relative risk for recurrent occlusion [3.0; 95% confidence intervals (CI): 1.5, 6.4] was greater for thrombectomy alone than for thrombolysis/angioplasty [0.6; CI = 0.3, 1.3]. The relative risks of repeat occlusion following thrombolysis/angioplasty [0.6; CI = 0.3, 1.3] and thrombectomy/surgical revision [1.0; CI = 0.5, 1.7] were similar. Conclusion: Outcome data from our retrospective study on recurrent thrombosis of PTFE dialysis access grafts suggest that thrombolysis/angioplasty is superior to thrombectomy alone, and equivalent to thrombectomy/surgical revision

  7. Comparison of Low-Dose Catheter-Directed Thrombolysis with and without Pharmacomechanical Thrombectomy for Acute Lower Extremity Ischemia.

    Science.gov (United States)

    Gandhi, Sagar S; Ewing, Joseph A; Cooper, Emily; Chaves, Jose Mauro; Gray, Bruce H

    2018-01-01

    Catheter-directed thrombolysis (CDT) and/or pharmacomechanical thrombectomy (PMT) can dissolve/remove thrombus; PMT alone, however, may require the adjunctive use of CDT. The aim of this study was to compare the use of CDT with and without PMT for the treatment of acute lower extremity ischemia (ALI). We retrospectively reviewed all patients with ALI who underwent CDT with or without PMT between January 2008 and April 2014 (n = 99). Patients with incomplete medical charts were excluded (n = 16). Remaining patients were divided into 2 cohorts: group 1 included patients who underwent PMT + CDT (n = 54); group 2 included those who underwent CDT alone (n = 29). Lesions were further characterized by anatomic location: iliac disease (n = 14), femoropopliteal disease (n = 53), tibial disease (n = 2), and multilevel disease (n = 14). Data collection included patient and limb characteristics, duration of treatment, complications, clinical outcomes, adjunctive interventions, and follow-up. No significant differences were seen between treatment groups in terms of patient characteristics, occlusion length and location, Rutherford class, median duration of ischemia time (P = 0.22), or mean lysis time (P = 0.58). Treatment groups were also similar with regard to outcomes, including periprocedure complications, patency, reintervention, limb salvage, and amputation-free survival. There was no different between PMT + CDT and CDT alone in terms of periprocedural complications or outcomes. In the quest to resolve ALI, initial thrombus extraction with PMT may not reduce the need, duration, or efficacy of CDT. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Anatomic and functional outcomes of pharmacomechanical and catheter-directed thrombolysis of iliofemoral deep venous thrombosis.

    Science.gov (United States)

    Hager, Eric; Yuo, Theodore; Avgerinos, Efthymios; Naddaf, Abdullah; Jeyabalan, Geetha; Marone, Luke; Chaer, Rabih

    2014-07-01

    Pharmacomechanical thrombolysis (PMT) and catheter-directed thrombolysis (CDT) are commonly used for the treatment of iliofemoral deep venous thrombosis (DVT). The purpose of this study was to examine the short- and long-term venous patency and venous valvular function as well as clinical outcomes of patients treated for iliofemoral DVT by PMT and CDT. A retrospective review of all patients with symptomatic DVT treated between 2006 and 2011 with PMT or CDT was performed. All patients were treated by local tissue plasminogen activator delivered with PMT or CDT. Patients were divided into two groups on the basis of initial treatment modality: patients treated by PMT alone (group 1), and those who underwent PMT and CDT or CDT alone (group 2). Group comorbidities, initial presenting symptoms, and Clinical, Etiologic, Anatomic, and Pathologic (CEAP) classification scores were compared. Postprocedural duplex ultrasound was used to assess valve function and treated vein patency rates. At all visits, Villalta and CEAP scores were recorded and compared. Group demographic and procedural results were analyzed by Fisher exact test for dichotomous variables and Kruskal-Wallis equality-of-populations rank test for the ordinal and continuous data. Kaplan-Meier survival estimates were used to assess preserved valve function as well as primary and secondary patency rates. There were 79 patients with 102 limbs treated for extensive iliofemoral DVT (median age, 51.5 years; range, 16.6-83.8 years). There were 18 patients in group 1 and 61 patients in group 2 (PMT + CDT [n = 54] or CDT alone [n = 7]). There were no differences in demographics or comorbidities between groups aside from malignant disease, which was more common in group 1 (35.3% vs 11.5%; P = .03). A total of 102 limbs were analyzed, 24 in group 1 and 78 in group 2. Patients in group 1 had a shorter symptom duration compared with group 2 (7 days vs 16 days; P = .011). The median number of procedures in group 1

  9. Relationship between thrombolysis efficiency induced by pulsed focused ultrasound and cavitation bubble size

    International Nuclear Information System (INIS)

    Xu, S; Liu, X; Wang, S; Wan, M

    2015-01-01

    In this study, the relationship between the efficiency of pulsed focused ultrasound (FUS)-induced thrombolysis and the size distribution of cavitation bubbles has been studied. Firstly, the thrombolysis efficiency, evaluated by degree of mechanical fragmentation was investigated with varying duty cycle. Secondly, the size distribution of cavitation bubbles after the 1st, 10 3 th and 10 5 th pulse during experiments for various duty cycles was studied. It was revealed that the thrombolysis efficiency was highest when the cavitation bubble size distribution was centred around linear resonance radius of the emission frequency of the FUS transducer. Therefore, in cavitation enhanced therapeutic applications, the essential of using a pulsed FUS may be controlling the size distribution of cavitation nuclei within an active size range so as to increase the treatment efficiency. (paper)

  10. Outcomes and predictors of failure of thrombolysis for iliofemoral deep venous thrombosis.

    Science.gov (United States)

    Avgerinos, Efthymios D; Hager, Eric S; Naddaf, Abdallah; Dillavou, Ellen; Singh, Michael; Chaer, Rabih A

    2015-01-01

    Catheter-directed thrombolysis (CDT) with adjunctive mechanical techniques, when successful, is reported to alleviate symptoms of acute iliofemoral deep venous thrombosis (IFDVT) and to lower the occurrence of the post-thrombotic syndrome (PTS). This study aimed to determine longer term outcomes of catheter-based interventions for IFDVT and to identify predictors of immediate and mid-long-term failures that would guide optimal patient selection. Consecutive patients who underwent CDT or pharmacomechanical thrombolysis for IFDVT between May 2007 and March 2013 were identified from a prospectively maintained database. Assessment of predictors of immediate periprocedural failure was based on the degree of clot lysis (≤ 50% vs >50%) and 30-day recurrence of DVT. Long-term anatomic and clinical failures and outcomes were assessed by ultrasound imaging of the lysed segments and Villalta score (≥ 5 vs <5). Survival analysis was used to assess primary patency and PTS morbidity. Multivariate binary logistic and Cox regression models were used to determine predictors of anatomic and clinical failures. During the study period, 93 patients (118 limbs; mean age, 49.4 ± 16.2 years; 47 women) with symptoms averaging 11.1 ± 9.6 days in duration were treated with various combinations of CDT or pharmacomechanical thrombolysis; in 52 (56%), at least one iliocaval stent was deployed. Immediate treatment failure was seen in 11 patients (12%) predicted by the preoperative indication "phlegmasia" (odds ratio, 3.12; P = .042) and recent surgery (odds ratio, 19.6; P = .018). At a mean ultrasonographic follow-up of 16 ± 14 months (range, 1-65 months), six more patients sustained a rethrombosis, accounting for an overall 3-year primary patency of 72.1%. In the long-term model, loss of primary patency was associated with recent surgery (hazard ratio [HR], 4.04; P = .023), malignant disease (HR, 6.75; P = .016), and incomplete thrombolysis (≤ 50%) (HR, 5.83; P < .001). By

  11. Pharmacomechanical Thrombectomy in Paget–Schroetter Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kärkkäinen, Jussi M., E-mail: jkarkkai@gmail.com [Kuopio University Hospital, Heart Center (Finland); Nuutinen, Henrik [Kuopio University Hospital, Department of Surgery (Finland); Riekkinen, Teemu [Kuopio University Hospital, Heart Center (Finland); Sihvo, Eero [Central Finland Central Hospital, Department of Surgery (Finland); Turtiainen, Johanna [North Karelia Central Hospital, Department of Surgery (Finland); Saari, Petri [Kuopio University Hospital, Department of Clinical Radiology (Finland); Mäkinen, Kimmo [Kuopio University Hospital, Heart Center (Finland); Manninen, Hannu [Kuopio University Hospital, Department of Clinical Radiology (Finland)

    2016-09-15

    PurposeThe purpose of the study was to evaluate feasibility of pharmacomechanical thrombectomy (PMT) in the treatment of Paget–Schroetter syndrome (PSS) followed by thoracoscopic or open surgical decompression of the subclavian vein.MethodsTwenty-two out of 27 consecutive patients with PSS received PMT using the Trellis-8 peripheral infusion system (Covidien) between 2010 and 2014. Subsequent surgery was performed in 18 of those patients, 9 patients were treated with thoracoscopic, 7 patients with subclavicular, and 2 patients with transaxillary first rib resection, 4 patients were treated with PMT and anticoagulation alone. Technical success, complications, and patency were registered.ResultsPMT was successful in 21 (95 %) patients; 1 patient with unsatisfactory lysis received further catheter-directed thrombolysis, which, however, did not improve the result. The mean endovascular procedure time was 105 ± 33 min (range 70–200 min), and the required median amount of thrombolytic agent was 500,000 international unit (IU; range 250,000–1,000,000 IU). Adjunctive balloon venoplasty and aspiration were used in 18 (82 %) and 7 (32 %) cases, respectively. One patient had an intimal tear of the subclavian vein that was discovered and repaired during surgery. There were no other complications related to the endovascular procedure. At follow-up, 18 of 21 patients (86 %) with follow-up imaging available had patent subclavian vein, and all except 1 of the 22 patients were asymptomatic. The mean follow-up time was 25 ± 17 months.ConclusionsIn experienced hands, PMT is effective for early thrombus removal in PSS. Surgical decompression must be considered after PMT.

  12. Using a new device to prevent pulmonary embolisms during pharmacomechanical thrombectomy.

    Science.gov (United States)

    Calleja, E; Ciampi, J J; Puche, J J; Lanciego, C

    2018-04-20

    We have used a new device to prevent pulmonary embolism during pharmacomechanical thrombectomy in a 25-year-old postpartum woman. The Angel® catheter (BiO2 Medical Inc., Golden, CO, USA) is a temporary device that combines the functions of a vena cava filter (VCF) with those of a triple-lumen central venous catheter. Normally, a VCF is implanted to prevent pulmonary embolism during pharmacomechanical thrombectomy. However, the complications associated with VCFs increase with time, not all of the filter can always be retrieved, and there can be iatrogenic effects both during implantation and retrieval. In our experience, this new device is much simpler to deploy and to retrieve. As is shown in this case, this temporary device can be an interesting alternative to a VCF for preventing pulmonary embolisms during pharmacomechanical thrombectomy. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Role of Catheter-directed Thrombolysis in Management of Iliofemoral Deep Venous Thrombosis.

    Science.gov (United States)

    Chen, James X; Sudheendra, Deepak; Stavropoulos, S William; Nadolski, Gregory J

    2016-01-01

    The treatment for iliofemoral deep venous thrombosis (DVT) is challenging, as the use of anticoagulation alone can be insufficient for restoring venous patency and thus lead to prolongation of acute symptoms and an increased risk of chronic complications, including venous insufficiency and postthrombotic syndrome (PTS). In these cases, earlier and more complete thrombus removal can ameliorate acute symptoms and reduce long-term sequelae. Endovascular therapies involving the use of pharmacologic, mechanical, and combined pharmacomechanical modalities have been developed to achieve these goals. The most frequently used of these techniques, catheter-directed thrombolysis (CDT), involves the infusion of a thrombolytic agent through a multiple-side-hole catheter placed within the thrombosed vein to achieve high local doses and thereby break down the clot while minimizing systemic thrombolytic agent exposure. Randomized controlled trial results have indicated decreased PTS rates and improved venous patency rates in patients treated with CDT compared with these rates in patients treated with anticoagulation. The use of newer pharmacomechanical techniques, as compared with conventional CDT, reduces procedural times and thrombolytic agent doses and is the subject of ongoing investigations. Endovascular thrombus removal techniques offer a means to improve venous valvular function and decrease the risk of debilitating long-term complications such as PTS and are a promising option for treating patients with iliofemoral DVT. (©)RSNA, 2016.

  14. Efficacy of Lower-Extremity Venous Thrombolysis in the Setting of Congenital Absence or Atresia of the Inferior Vena Cava

    International Nuclear Information System (INIS)

    Ganguli, Suvranu; Kalva, Sanjeeva; Oklu, Rahmi; Walker, T. Gregory; Datta, Neil; Grabowski, Eric F.; Wicky, Stephan

    2012-01-01

    Purpose: A rare but described risk factor for deep venous thrombosis (DVT), predominately in the young, is congenital agenesis or atresia of the inferior vena cava (IVC). The optimal management for DVT in this subset of patients is unknown. We evaluated the efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) followed by systemic anticoagulation in the treatment of acute lower-extremity DVT in the setting of congenital IVC agenesis or atresia. Materials and Methods: Between November of 2005 and May of 2010, six patients (three women [average age 21 years]) were referred to our department with acute lower-extremity DVT and subsequently found to have IVC agenesis or atresia on magnetic resonance imaging. A standardized technique for PCDT (the Angiojet Rheolytic Thrombectomy System followed by the EKOS Microsonic Accelerated Thrombolysis System) was used for all subjects. Successful thrombolysis was followed by systemic heparinization with transition to Coumadin or low molecular-weight heparin and compression stockings. Subjects were followed-up at 1, 3, and then every 6 months after the procedure with clinical assessment and bilateral lower-extremity venous ultrasound. Results: All PCDT procedures were technically successful. No venous stenting or angioplasty was performed. The average thrombolysis time was 28.6 h (range 12–72). Two patients experienced heparin-induced thrombocytopenia, and one patient developed a self-limited knee hemarthrosis, No patients were lost to follow-up. The average length of follow-up was 25.8 ± 20.2 months (range 3.8–54.8). No incidence of recurrent DVT was identified. There were no manifestations of postthrombotic syndrome. Conclusions: PCDT followed by systemic anticoagulation and the use of compression stockings appears to be safe and effective in relatively long-term follow-up treatment of patients who present with acute DVT and IVC agenesis or atresia.

  15. Water spray assisted ultrashort laser pulse ablation

    International Nuclear Information System (INIS)

    Silvennoinen, M.; Kaakkunen, J.J.J.; Paivasaari, K.; Vahimaa, P.

    2013-01-01

    Highlights: ► We show the novel method to use multibeam processing with ultrashort pulses efficiently. ► Sprayed thin water layer on ablation zone enhances ablation rate and quality. ► In some cases this method also enables ablation of the deeper and straighter holes compared to ones made without the water layer. ► Method also makes possible to directly write features without the self-organizing structures. - Abstract: We have studied femtosecond ablation under sprayed thin water film and its influence and benefits compared with ablation in the air atmosphere. These have been studied in case of the hole and the groove ablation using IR femtosecond laser. Water enhances the ablation rate and in some situations it makes possible to ablate the holes with a higher aspect ratio. While ablating the grooves, the water spray allows using the high fluences without the generation of the self-organized structures.

  16. Investigating Tribological Characteristics of HVOF Sprayed AISI 316 Stainless Steel Coating by Pulsed Plasma Nitriding

    Science.gov (United States)

    Mindivan, H.

    2018-01-01

    In this study, surface modification of aluminum alloy using High-Velocity Oxygen Fuel (HVOF) thermal spray and pulsed plasma nitriding processes was investigated. AISI 316 stainless steel coating on 1050 aluminum alloy substrate by HVOF process was pulsed plasma nitrided at 793 K under 0.00025 MPa pressure for 43200 s in a gas mixture of 75 % N2 and 25 % H2. The results showed that the pulse plasma nitriding process produced a surface layer with CrN, iron nitrides (Fe3N, Fe4N) and expanded austenite (γN). The pulsed plasma nitrided HVOF-sprayed coating showed higher surface hardness, lower wear rate and coefficient of friction than the untreated HVOF-sprayed one.

  17. Application of pulse combustion technology in spray drying process

    Directory of Open Access Journals (Sweden)

    I. Zbicinski

    2000-12-01

    Full Text Available The paper presents development of valved pulse combustor designed for application in drying process and drying tests performed in a specially built installation. Laser technique was applied to investigate the flow field and structure of dispersed phase during pulse combustion spray drying process. PDA technique was used to determine initial atomization parameters as well as particle size distribution, velocity of the particles, mass concentration of liquid phase in the cross section of spray stream, etc., in the drying chamber during drying tests. Water was used to estimate the level of evaporation and 5 and 10% solutions of sodium chloride to carry out drying tests. The Computational Fluid Dynamics technique was used to perform theoretical predictions of time-dependent velocity, temperature distribution and particle trajectories in the drying chamber. Satisfactory agreement between calculations and experimental results was found in certain regions of the drying chamber.

  18. Thin solid films deposited by pulsed laser ablating spray

    International Nuclear Information System (INIS)

    Song Guangle

    2002-01-01

    The fabricating technique of thin solid films deposited by pulsed laser ablating spray is a new technique. The background from which it came into being and the process of its evolution were briefly described. According to relative documents, basic principle of the technique was dwelt on. Based on the latest documents, the status quo, including the studying abroad and home, was discussed in detail. The advantages, shortcomings, prospect of its utility, the significance of studying as well as critic problems were summarized. Some proposal was suggested

  19. ENDOVASCULAR TREATMENT FOR DISORDERS OF THE VENOUS SYSTEM

    Directory of Open Access Journals (Sweden)

    A. G. Osiev

    2015-01-01

    Full Text Available The annual rate of deep vein thrombosis in general population is from 5 to 9 cases per 10 000, whereas for venous thromboembolism (deep vein thrombosis and pulmonary embolism taken together amounts to 14 cases per 10 000. To improve longterm results of therapy for thrombosis of deep veins of the lower extremities, it is important to restore venous function and outflow. Anticoagulant therapy with low weight or non-fractionated heparin preparations remains the most widely used method of management. However, total or partial thrombosis resolution under anticoagulant treatment is achieved only in 4 and 14% of cases, respectively. Thrombolysis allows for early resorption of the thrombus by means of a minimally invasive procedure with lower risk of complication. After the venous flow is restored, the aim of treatment is to prevent damage to the venous valves, venous hypertension and repeated thrombosis with development of the post-thrombotic syndrome. Compared to anticoagulation, systemic thrombolysis has the benefit of more rapid clot resorption and less damage to the venous valve. One of its serious limitations is a high bleeding risk related to higher doses of the drug administered through a peripheral vein catheter. Therefore, selective intra-clot administration of thombolytics (direct catheter thrombolysis has been suggested as an alternative. For more effective therapy with the use of lower doses of thrombolytics, the so called pharmaco-mechanical thrombectomy has been developed. Venous stenosis hindering the venous outflow is frequently seen after direct catheter or pharmaco-mechanical thrombolysis. Angioplasty with stent placement is recommended in the cases with residual venous abnormality after successful thrombolysis and thrombectomy. 

  20. Evaluation of pulsed laser holograms of flashing sprays by digital image processing and holographic particle image velocimetry

    International Nuclear Information System (INIS)

    Feldmann, O.; Gebhard, P.; Mayinger, F.

    1998-01-01

    This study deals with the application of the pulsed laser holography and the digital image processing in the analysis of flashing sprays. Both the information about the macroscopic structures of a spray, such as the breakup-length and the spray-angle, and about its microscopic structures, such as the number, the size, and the location of the generated droplets is stored three-dimensionally on a single pulsed hologram. In addition to that, the velocity of the droplets can be obtained from double pulsed holograms. In every experiment, two holograms are taken, resulting in two three-dimensional reconstructions of the test section, seen from different directions. These reconstructions are scanned by video-cameras with a small depth of field and subdivided into several two-dimensional images. These images are digitized and binarized, and the information about the droplets depicted sharply on each image is saved. In case of a double pulsed hologram, a Fourier-analysis based algorithm creates a search volume to determine the droplets' second position and thus their velocity in each view. A stereo matching modulus correlates both views and determines the position and/or the velocity of each droplet highly accurate. The applicability of the employed holographic technique and the filtering and correlating moduli is proven by the presented results. (author)

  1. Deposition and characterization of ZnO thin films by modified pulsed-spray pyrolysis

    International Nuclear Information System (INIS)

    Thilakan, Periyasamy; Radheep, D Mohan; Saravanakumar, K; Sasikala, G

    2009-01-01

    Zinc oxide (ZnO) thin films were deposited using modified pulsed-spray pyrolysis on glass substrates. Depositions were carried out using N 2 as the carrier gas and analysed with respect to the rate of deposition. X-ray analysis revealed the presence of mixed crystallization with a nanocrystalline structure of about 6.9 nm dispersed in the amorphous matrix. A negative trend between the bandgap and resistivity was observed with the decrease in the deposition rate. A lowest bandgap of 3.1 eV with a resistivity value of 1.6 × 10 −2 Ω cm was achieved at a lowest deposition rate of 1.3 nm min −1 . Hot-probe measurement revealed the p-type conductivity for the film deposited at a lowest deposition rate of 1.3 nm min −1 . Details about the influence of pulsed-spray deposition for the achievement of this negative trend between bandgap and resistivity will be discussed in this paper

  2. [Prehospital thrombolysis during cardiopulmonary resuscitation].

    Science.gov (United States)

    Spöhr, F; Böttiger, B W

    2005-02-01

    Although prehospital cardiac arrest has an incidence of 40-90/100,000 inhabitants per year, there has been a lack of therapeutic options to improve the outcome of these patients. Of all cardiac arrests, 50-70% are caused by acute myocardial infarction (AMI) or massive pulmonary embolism (PE). Thrombolysis has been shown to be a causal and effective therapy in patients with AMI or PE who do not suffer cardiac arrest. In contrast, experience with the use of thrombolysis during cardiac arrest has been limited. Thrombolysis during cardiopulmonary resuscitation (CPR) acts directly on thrombi or emboli causing AMI or PE. In addition, experimental studies suggest that thrombolysis causes an improvement in microcirculatory reperfusion after cardiac arrest. In-hospital and prehospital case series and clinical studies suggest that thrombolysis during CPR may cause a restoration of spontaneous circulation and survival even in patients that have been resuscitated conventionally without success. In addition, there is evidence for an improved neurological outcome in patients receiving a thrombolytic therapy during during CPR. A large randomized, double-blind multicenter trial that has started recently is expected to show if this new therapeutic option can generally improve the prognosis of patients with cardiac arrest.

  3. Detection and Characterization of Flaws in Sprayed on Foam Insulation with Pulsed Terahertz Frequency Electromagnetic Waves

    Science.gov (United States)

    Winfree, William P.; Madaras, Eric I.

    2005-01-01

    The detection and repair of flaws such as voids and delaminations in the sprayed on foam insulation of the external tank reduces the probability of foam debris during shuttle ascent. The low density of sprayed on foam insulation along with it other physical properties makes detection of flaws difficult with conventional techniques. An emerging technology that has application for quantitative evaluation of flaws in the foam is pulsed electromagnetic waves at terahertz frequencies. The short wavelengths of these terahertz pulses make them ideal for imaging flaws in the foam. This paper examines the application of terahertz pulses for flaw detection in foam characteristic of the foam insulation of the external tank. Of particular interest is the detection of voids and delaminations, encapsulated in the foam or at the interface between the foam and a metal backing. The technique is shown to be capable of imaging small voids and delaminations through as much as 20 cm of foam. Methods for reducing the temporal responses of the terahertz pulses to improve flaw detection and yield quantitative characterizations of the size and location of the flaws are discussed.

  4. Intra-arterial thrombolysis vs. standard treatment or intravenous thrombolysis in adults with acute ischemic stroke: a systematic review and meta-analysis.

    Science.gov (United States)

    Nam, Julian; Jing, He; O'Reilly, Daria

    2015-01-01

    Recent evidence has suggested that intra-arterial thrombolysis may provide benefit beyond intravenous thrombolysis in ischemic stroke patients. Previous meta-analyses have only compared intra-arterial thrombolysis with standard treatment without thrombolysis. The objective was to review the benefits and harms of intra-arterial thrombolysis in ischemic stroke patients. We undertook a meta-analysis of randomized controlled trials comparing the efficacy and safety of intra-arterial thrombolysis with either standard treatment or intravenous thrombolysis following acute ischemic stroke. Primary outcomes included poor functional outcomes (modified Rankin Scale 3-6), mortality, and symptomatic intracranial hemorrhage. Study quality was assessed, and outcomes were stratified by comparison treatment received. Four trials (n = 351) comparing intra-arterial thrombolysis with standard treatment were identified. Intra-arterial thrombolysis reduced the risk of poor functional outcomes (modified Rankin Scale 3-6) [relative risk (RR) = 0·80; 95% confidence interval = 0·67-0·95; P = 0·01]. Mortality was not increased (RR = 0·82; 95% confidence interval = 0·56-1·21; P = 0·32); however, risk of symptomatic intracranial hemorrhage was nearly four times more likely (RR = 3·90; 95% confidence interval = 1·41-10·76; P = 0·006). Two trials (n = 81) comparing intra-arterial thrombolysis with intravenous thrombolysis were identified. Intra-arterial thrombolysis was not found to reduce poor functional outcomes (modified Rankin Scale 3-6) (RR = 0·68; 95% confidence interval = 0·46-1·00; P = 0·05). Mortality was not increased (RR = 1·12; 95% confidence interval = 0·47-2·68; P = 0·79); neither was symptomatic intracranial hemorrhage (RR = 1·13; 95% confidence interval = 0·32-3·99; P = 0·85). Differences in time from symptom onset-to-treatment and type of thrombolytic administered were found

  5. [Endovascular treatment of acute iliofemoral deep venous thrombosis - our results with catheter-directed thrombolysis and AngioJet].

    Science.gov (United States)

    Berencsi, Anikó; Dósa, Edit; Nemes, Balázs; Hüttl, Kálmán; Legeza, Péter; Oláh, Zoltán; Kristóf, Vera; Acsády, György; Sótonyi, Péter

    2017-03-01

    Most of the patients with iliofemoral thrombosis treated with anticoagulants only are affected with postthrombotic syndrome (PTS) that worsens the patients' quality of life. In the acute phase of proximal deep venous thrombosis (DVT) catheter-directed (CDT) and pharmacomechanical thrombolysis may be a reasonable alternative therapeutic method. Our aim was to summarize our results using these methods. Since 2009 twenty-four patients with iliofemoral DVT were treated with these endovascular procedures and with stenting at our Institution. The median age of the patients was 35.83 ± 15.9 years, the female: male ratio was approximately 2:1. The mean time between the onset of the symptoms and the procedures was eleven days. CDT alone was performed in 8 patients, thrombus aspiration in addition to CDT using AngioJet device in 16 patients; in 19 cases the procedure was completed with venous stenting. During the follow-up we performed US examinations and estimated the severity of PTS by Villalta-scale. The total recanalization-rate was more than 50%, which even improved during the follow-up. The total lysis time and the amount of used recombinant tissue plasminogen activator decreased significantly by applying the AngioJet. We did not find any severe PTS among our patients during the follow-up visits. Our data suggests that these methods can be used efficiently and safely in the treatment of acute iliofemoral DVT.

  6. Dutch randomized trial comparing standard catheter-directed thrombolysis versus Ultrasound-accElerated Thrombolysis for thromboembolic infrainguinal disease (DUET: design and rationale

    Directory of Open Access Journals (Sweden)

    Fioole Bram

    2011-01-01

    Full Text Available Abstract Background The use of thrombolytic therapy in the treatment of thrombosed infrainguinal native arteries and bypass grafts has increased over the years. Main limitation of this treatment modality, however, is the occurrence of bleeding complications. Low intensity ultrasound (US has been shown to accelerate enzymatic thrombolysis, thereby reducing therapy time. So far, no randomized trials have investigated the application of US-accelerated thrombolysis in the treatment of thrombosed infra-inguinal native arteries or bypass grafts. The DUET study (Dutch randomized trial comparing standard catheter-directed thrombolysis versus Ultrasound-accElerated Thrombolysis for thrombo-embolic infrainguinal disease is designed to assess whether US-accelerated thrombolysis will reduce therapy time significantly compared with standard catheter-directed thrombolysis. Methods/design Sixty adult patients with recently (between 1 and 7 weeks thrombosed infrainguinal native arteries or bypass grafts with acute limb ischemia class I or IIa, according to the Rutherford classification for acute ischemia, will be randomly allocated to either standard thrombolysis (group A or US-accelerated thrombolysis (group B. Patients will be recruited from 5 teaching hospitals in the Netherlands during a 2-year period. The primary endpoint is the duration of catheter-directed thrombolysis needed for uninterrupted flow in the thrombosed infrainguinal native artery or bypass graft, with outflow through at least 1 crural artery. Discussion The DUET study is a randomized controlled trial that will provide evidence of whether US-accelerated thrombolysis will significantly reduce therapy time in patients with recently thrombosed infrainguinal native arteries or bypass grafts, without an increase in complications. Trial registration Current Controlled Trials ISRCTN72676102

  7. Pulse sliced picosecond Ballistic Imaging and two planar elastic scattering: Development of the techniques and their application to diesel sprays

    Science.gov (United States)

    Duran, Sean Patrick Hynes

    A line of sight imaging technique was developed which utilized pulse slicing of laser pulses to shorten the duration of the parent laser pulse, thereby making time gating more effective at removing multiple scattered light. This included the development of an optical train which utilized a Kerr cell to selectively pass the initial part of the laser pulse while rejecting photons contained later within the pulse. This line of sight ballistic imaging technique was applied to image high-pressure fuel sprays injected into conditions typically encountered in a diesel combustion chamber. Varying the environmental conditions into which the fuel was injected revealed trends in spray behavior which depend on both temperature and pressure. Different fuel types were also studied in this experiment which demonstrated remarkably different shedding structures from one another. Additional experiments were performed to characterize the imaging technique at ambient conditions. The technique was modified to use two wavelengths to allow further rejection of scattered light. The roles of spatial, temporal and polarization filtration were examined by imaging an USAF 1951 line-pair target through a highly scattering field of polystyrene micro-spheres. The optical density of the scattering field was varied by both the optical path length and number densities of the spheres. The equal optical density, but with variable path length results demonstrated the need for an aggressively shorter pulse length to effectively image the distance scales typical encountered in the primary breakup regions of diesel sprays. Results indicate that the system performance improved via the use of two wavelengths. A final investigation was undertaken to image coherent light which has elastically scattered orthogonal to the direction of the laser pulse. Two wavelengths were focused into ˜150 micron sheets via a cylindrical lens and passed under the injector nozzle. The two sheets were adjustable spatially to

  8. Spray and microjets produced by focusing a laser pulse into a hemispherical drop

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2009-11-02

    We use high-speed video imaging to study laser disruption of the free surface of a hemispheric drop. The drop sits on a glass surface and the Nd:YAG (yttrium aluminum garnet) laser pulse propagates through the drop and is focused near the free surface from below. We focus on the evolution of the cylindrical liquid sheet and spray which emerges out of the drop and resembles typical impact crowns. The tip of the sheet emerges at velocities over 1 km/s. The tip of the crown breaks up into fine spray some of which is sucked back into the growing cavity at about 100 m/s. We measure the size of the typical spray droplets to be about 3 μm. We also show the formation of fine microjets, which are produced when the laser is focused inside the drop and the shock front hits small bubbles sitting under the free surface. For water these microjets are 5–50 μm in diameter and exit at 100–250 m/s. For higher viscositydrops, these jets can emerge at over 500 m/s.

  9. Spray and microjets produced by focusing a laser pulse into a hemispherical drop

    KAUST Repository

    Thoroddsen, Sigurdur T; Takehara, K.; Etoh, T. G.; Ohl, C.-D.

    2009-01-01

    We use high-speed video imaging to study laser disruption of the free surface of a hemispheric drop. The drop sits on a glass surface and the Nd:YAG (yttrium aluminum garnet) laser pulse propagates through the drop and is focused near the free surface from below. We focus on the evolution of the cylindrical liquid sheet and spray which emerges out of the drop and resembles typical impact crowns. The tip of the sheet emerges at velocities over 1 km/s. The tip of the crown breaks up into fine spray some of which is sucked back into the growing cavity at about 100 m/s. We measure the size of the typical spray droplets to be about 3 μm. We also show the formation of fine microjets, which are produced when the laser is focused inside the drop and the shock front hits small bubbles sitting under the free surface. For water these microjets are 5–50 μm in diameter and exit at 100–250 m/s. For higher viscositydrops, these jets can emerge at over 500 m/s.

  10. Sequestrated thrombolysis: Comparative evaluation in vivo

    International Nuclear Information System (INIS)

    Roy, Sumit; Laerum, Frode; Brosstad, Frank; Kvernebo, Knut; Sakariassen, Kjell S.

    2000-01-01

    Purpose: Lysis of a thrombus is a function of the local concentration of thrombolytic enzymes. This study was designed to determine in a porcine model of acute deep vein thrombosis (DVT) whether perithrombic sequestration of small volumes of a concentrated enzyme solution can accelerate the process of thrombolysis.Methods: DVT was induced in both hind limbs using a previously described technique (n=32). Thirty minutes later the animal was heparinized and unilateral thrombolysis was attempted using 8 mg recombinant tissue plasminogen activator (rt-PA); saline was administered in the opposite leg. For conventional high-volume infusion (CI) (n=5) rt-PA (0.067 mg/ml) was infused at l ml/min. For sequestrated thrombolysis the external iliac vein was endoluminally occluded, and rt-PA (0.25 mg/ml) administered either for proximal injection (ST-P) (n=5). as a bolus every 3 min through a microcatheter placed via the balloon catheter, or for transthrombic injection (ST-T) (n=5), as a bolus every 3 min through a Katzen wire in the balloon catheter. At autopsy, the thrombus mass in the iliofemoral veins was measured, and the extent of residual thrombosis in the venous tributaries graded at four sites. From these data a thrombolysis score was calculated.Results: One pig died before thrombolysis could be performed. Only with ST-T was residual thrombus mass in the test limb normalized to control, residual thrombus index (RTF), consistently less than unity. The median RTI of this group was 0.50 (range 0.39-0.97) compared with 1.22 (0.64-1.38) for ST-P and 0.88 (0.37-1.13) for CI. Compared with contralateral controls, a lower grade of residual thrombosis in tributaries was observed in test limbs at more venous sites with ST-T (8/20; 95% confidence interval 5-13) and ST-P (9/20; confidence interval 5-13) than with CI (2/20; confidence interval 0-5) (p=0.04). A trend toward lower thrombolysis scores was observed with ST-T (p=0.08). Systemic fibrinogenolysis was not observed in any of

  11. Intervention radiology for venous thrombosis: early thrombus removal using invasive methods.

    Science.gov (United States)

    Casanegra, Ana I; McBane, Robert D; Bjarnason, Haraldur

    2017-04-01

    The post thrombotic syndrome is one of the most dreaded complications of proximal deep vein thrombosis. This syndrome leads to pain and suffering with leg swelling, recalcitrant ulceration and venous claudication which greatly impairs mobility and quality of life. The prevalence can be high in patients with iliofemoral venous involvement particularly in the setting of a proximal venous stenosis, such as occurs in May Thurner syndrome. Anticoagulation alone does not reduce the likelihood of this outcome. Compression therapy may be effective but garment discomfort limits its implementation. Pharmacomechanical thrombectomy, which combines catheter-directed thrombolysis with mechanical thrombus dissolution, provides an attractive treatment strategy for such patients. The rationale and delivery of pharmacomechanical thrombectomy, including patient selection and adjunctive antithrombotic therapy, will be reviewed in addition to tips and tricks for managing difficult patient scenarios. © 2017 John Wiley & Sons Ltd.

  12. Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: an in vitro study

    International Nuclear Information System (INIS)

    Suo, Dingjie; Guo, Sijia; Jiang, Xiaoning; Jing, Yun; Lin, Weili

    2015-01-01

    High intensity focused ultrasound (HIFU) based thrombolysis has emerged as a promising drug-free treatment approach for ischemic stroke. The large amount of acoustic power required by this approach, however, poses a critical challenge to the future clinical translation. In this study, multi-frequency acoustic waves at MHz range (near 1.5 MHz) were introduced as HIFU excitations to reduce the required power for treatment as well as the treatment time. In vitro bovine blood clots weighing around 150 mg were treated by single-frequency and multi-frequency HIFU. The pulse length was 2 ms for all experiments except the ones where the duty cycle was changed. It was found that dual-frequency thrombolysis efficiency was statistically better than single-frequency under the same acoustic power and excitation condition. When varying the acoustic power but fixing the duty cycle at 5%, it was found that dual-frequency ultrasound can save almost 30% power in order to achieve the same thrombolysis efficiency. In the experiment where the duty cycle was increased from 0.5% to 10%, it was shown that dual-frequency ultrasound can achieve the same thrombolysis efficiency with only half of the duty cycle of single-frequency. Dual-frequency ultrasound could also accelerate the thrombolysis by a factor of 2–4 as demonstrated in this study. No significant differences were found between dual-frequencies with different frequency differences (0.025, 0.05, and 0.1 MHz) and between dual-frequency and triple-frequency. The measured cavitation doses of dual-frequency and triple-frequency excitations were at about the same level but both were significantly higher than that of single-frequency. (paper)

  13. Selective arterial thrombolysis with urokinase

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Park, Kil Sun; Chung, Jin Wook; Han, Joon Koo; Kim, Sang Joon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Young [Choong Buk University College of Medicine, Jeonju (Korea, Republic of)

    1991-07-15

    Seven patients with thrombotic occlusions of the peripheral arteries or grafts were treated with urokinase by direct intraarterial selective infusion. During the infusion, simultaneous heparin infusion was used to reduce the frequency of thrombus formation on the infusion catheter or recurrent thrombosis. In 4 patients in whom a complete thrombolysis occurred, urokinase was infused by a high-dose transthrombus bolus technique followed by continuous infusion. There other patients, in whom thrombolysis was partially accomplished and then surgical thrombectomy was performed, were treated only by continuous urokinase infusion. Small hematomas developed at the infusion catheter entry site in 2 patients, but transfusion or operation was not required. Other significant complications were not found. Our results suggest that selective arterial infusion of urokinase with a transthrombus bolus technique can accomplish a complete arterial thrombolysis without any significant complications.

  14. Selective arterial thrombolysis with urokinase

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Park, Kil Sun; Chung, Jin Wook; Han, Joon Koo; Kim, Sang Joon; Kim, Dae Young

    1991-01-01

    Seven patients with thrombotic occlusions of the peripheral arteries or grafts were treated with urokinase by direct intraarterial selective infusion. During the infusion, simultaneous heparin infusion was used to reduce the frequency of thrombus formation on the infusion catheter or recurrent thrombosis. In 4 patients in whom a complete thrombolysis occurred, urokinase was infused by a high-dose transthrombus bolus technique followed by continuous infusion. There other patients, in whom thrombolysis was partially accomplished and then surgical thrombectomy was performed, were treated only by continuous urokinase infusion. Small hematomas developed at the infusion catheter entry site in 2 patients, but transfusion or operation was not required. Other significant complications were not found. Our results suggest that selective arterial infusion of urokinase with a transthrombus bolus technique can accomplish a complete arterial thrombolysis without any significant complications

  15. How best to obtain consent to thrombolysis: Individualized decision-making.

    Science.gov (United States)

    Gong, Jingjing; Zhang, Yan; Feng, Jun; Zhang, Weiwei; Yin, Weimin; Wu, Xinhuai; Hou, Yanhong; Huang, Yonghua; Liu, Hongyun; Miao, Danmin

    2016-03-15

    To investigate the factors that influence the preferences of patients and their proxies concerning thrombolytic therapy and to determine how best to convey information. A total of 613 participants were randomly assigned to a positively or negatively framed group. Each participant completed a series of surveys. We applied latent class analysis (LCA) to explore participants' patterns of choices of thrombolysis and to classify the participants into different subgroups. Then we performed regression analyses to investigate predictors of classification of the participants into each subgroup and to establish a thrombolytic decision-making model. LCA indicated an optimal 3-subgroup model comprising intermediate, favorable to thrombolysis, and aversion to thrombolysis subgroups. Multiple regression analysis revealed that 10 factors predicted assignment to the intermediate subgroup and 4 factors predicted assignment to the aversion to thrombolysis subgroup compared with the favorable to thrombolysis subgroup. The χ(2) tests indicated that the information presentation format and the context of thrombolysis influenced participants' choices of thrombolysis and revealed a framing effect in different subgroups. The preference for thrombolysis was influenced by the positive vs negative framing scenarios, the format of item presentation, the context of thrombolysis, and individual characteristics. Inconsistent results may be due to participant heterogeneity and the evaluation of limited factors in previous studies. Based on a decision model of thrombolysis, physicians should consider the effects of positive vs negative framing and should seek a neutral tone when presenting the facts, providing an important reference point for health persuasion in other clinical domains. © 2016 American Academy of Neurology.

  16. Granule size control and targeting in pulsed spray fluid bed granulation.

    Science.gov (United States)

    Ehlers, Henrik; Liu, Anchang; Räikkönen, Heikki; Hatara, Juha; Antikainen, Osmo; Airaksinen, Sari; Heinämäki, Jyrki; Lou, Honxiang; Yliruusi, Jouko

    2009-07-30

    The primary aim of the study was to investigate the effects of pulsed liquid feed on granule size. The secondary aim was to increase knowledge of this technique in granule size targeting. Pulsed liquid feed refers to the pump changing between on- and off-positions in sequences, called duty cycles. One duty cycle consists of one on- and off-period. The study was performed with a laboratory-scale top-spray fluid bed granulator with duty cycle length and atomization pressure as studied variables. The liquid feed rate, amount and inlet air temperature were constant. The granules were small, indicating that the powder has only undergone ordered mixing, nucleation and early growth. The effect of atomizing pressure on granule size depends on inlet air relative humidity, with premature binder evaporation as a reason. The duty cycle length was of critical importance to the end product attributes, by defining the extent of intermittent drying and rewetting. By varying only the duty cycle length, it was possible to control granule nucleation and growth, with a wider granule size target range in increased relative humidity. The present study confirms that pulsed liquid feed in fluid bed granulation is a useful tool in end product particle size targeting.

  17. Choices Regarding Thrombolysis Are Modified by the Way to Transfer the Messages

    Directory of Open Access Journals (Sweden)

    Jingjing Gong

    2017-11-01

    Full Text Available Although thrombolysis is the most effective medical treatment for acute ischemic stroke, many stroke patients eligible for thrombolysis miss this treatment as a result of delay or refusal by the patients and/or their proxies. To explore the influences of prognostic information for different intervals from stroke onset to the start of thrombolytic treatment (OTT and other factors on the preferences of patients/proxies regarding thrombolytic therapy, a cross-sectional, discrete-choice experiment was performed between August 2013 and September 2014. A total of 613 Chinese inpatients or their immediate family members were consecutively recruited at the Department of Neurology. After random assignment to a negative-framing group or a positive-framing group, the subjects completed a series of surveys, including nine items about thrombolysis. Latent class analysis (LCA was used to examine participants’ preference paradigms for thrombolysis and to categorize the participants into different subgroups. Subsequently, regression analyses were conducted to explore predictors of categorization of the participants into each subgroup and to construct a thrombolytic decision-making model. LCA revealed an optimal 3-subgroup model including a consent to thrombolysis subgroup and objection to thrombolysis subgroups 1 and 2. Multiple regression analysis demonstrated that compared with assignment to the consent to thrombolysis subgroup, assignment to objection to thrombolysis subgroup 1 or 2 could be predicted by different factors. χ2 tests indicated effects of framing and other factors on participants’ choices regarding thrombolysis. Choices regarding thrombolysis were modified by not only prognostic information for different OTT intervals but also message framing, presentation format, and sociodemographic characteristics. To facilitate consent to thrombolysis, physicians should convey prognostic information to patients/proxies on the basis of patient OTT

  18. Choices Regarding Thrombolysis Are Modified by the Way to Transfer the Messages.

    Science.gov (United States)

    Gong, Jingjing; Zhang, Yan; Gao, Hongyan; Wei, Wei; Lv, Jing; Liu, Hongyun; Huang, Yonghua

    2017-01-01

    Although thrombolysis is the most effective medical treatment for acute ischemic stroke, many stroke patients eligible for thrombolysis miss this treatment as a result of delay or refusal by the patients and/or their proxies. To explore the influences of prognostic information for different intervals from stroke onset to the start of thrombolytic treatment (OTT) and other factors on the preferences of patients/proxies regarding thrombolytic therapy, a cross-sectional, discrete-choice experiment was performed between August 2013 and September 2014. A total of 613 Chinese inpatients or their immediate family members were consecutively recruited at the Department of Neurology. After random assignment to a negative-framing group or a positive-framing group, the subjects completed a series of surveys, including nine items about thrombolysis. Latent class analysis (LCA) was used to examine participants' preference paradigms for thrombolysis and to categorize the participants into different subgroups. Subsequently, regression analyses were conducted to explore predictors of categorization of the participants into each subgroup and to construct a thrombolytic decision-making model. LCA revealed an optimal 3-subgroup model including a consent to thrombolysis subgroup and objection to thrombolysis subgroups 1 and 2. Multiple regression analysis demonstrated that compared with assignment to the consent to thrombolysis subgroup, assignment to objection to thrombolysis subgroup 1 or 2 could be predicted by different factors. χ 2 tests indicated effects of framing and other factors on participants' choices regarding thrombolysis. Choices regarding thrombolysis were modified by not only prognostic information for different OTT intervals but also message framing, presentation format, and sociodemographic characteristics. To facilitate consent to thrombolysis, physicians should convey prognostic information to patients/proxies on the basis of patient OTT interval and should order

  19. Early thrombus removal strategies for acute deep venous thrombosis: clinical practice guidelines of the Society for Vascular Surgery and the American Venous Forum.

    Science.gov (United States)

    Meissner, Mark H; Gloviczki, Peter; Comerota, Anthony J; Dalsing, Michael C; Eklof, Bo G; Gillespie, David L; Lohr, Joann M; McLafferty, Robert B; Murad, M Hassan; Padberg, Frank; Pappas, Peter; Raffetto, Joseph D; Wakefield, Thomas W

    2012-05-01

    The anticoagulant treatment of acute deep venous thrombosis (DVT) has been historically directed toward the prevention of recurrent venous thromboembolism. However, such treatment imperfectly protects against late manifestations of the postthrombotic syndrome. By restoring venous patency and preserving valvular function, early thrombus removal strategies can potentially decrease postthrombotic morbidity. A committee of experts in venous disease was charged by the Society for Vascular Surgery and the American Venous Forum to develop evidence-based practice guidelines for early thrombus removal strategies, including catheter-directed pharmacologic thrombolysis, pharmacomechanical thrombolysis, and surgical thrombectomy. Evidence-based recommendations are based on a systematic review and meta-analysis of the relevant literature, supplemented when necessary by less rigorous data. Recommendations are made according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology, incorporating the strength of the recommendation (strong: 1; weak: 2) and an evaluation of the level of the evidence (A to C). On the basis of the best evidence currently available, we recommend against routine use of the term "proximal venous thrombosis" in favor of more precise characterization of thrombi as involving the iliofemoral or femoropopliteal venous segments (Grade 1A). We further suggest the use of early thrombus removal strategies in ambulatory patients with good functional capacity and a first episode of iliofemoral DVT of venous outflow obstruction (Grade 1A). We suggest pharmacomechanical strategies over catheter-directed pharmacologic thrombolysis alone if resources are available and that surgical thrombectomy be considered if thrombolytic therapy is contraindicated (Grade 2C). Most data regarding early thrombus removal strategies are of low quality but do suggest patient-important benefits with respect to reducing postthrombotic morbidity. We

  20. t-PA power-pulse spray with rheolytic mechanical thrombectomy using cross-sectional image-guided portal vein access for single setting treatment of subacute superior mesenteric vein thrombosis.

    Science.gov (United States)

    Syed, Mubin I; Gallagher, Ryan M; Ahmed, Rukan S; Shaikh, Azim; Roberto, Edward; Patel, Sumeet

    2018-01-01

    Isolated superior mesenteric vein (SMV) thrombosis is a rare but potentially fatal condition if untreated. Current treatments include transjugular or transhepatic approaches for rheolytic mechanical thrombectomy and subsequent infusions of thrombolytics. Tissue plasminogen activator (t-PA) power-pulse spray can provide benefit in a single setting without thrombolytic infusions. Computed tomography (CT) guidance for portal vein access is underutilized in this setting. Case 1 discusses acute SMV thrombosis treated with rheolytic mechanical thrombectomy alone using ultrasound guidance for portal vein access. Case 2 discusses subacute SMV thrombosis treated with the addition of t-PA power-pulse spray to the rheolytic mechanical thrombectomy, using CT guidance for portal vein access. With rheolytic mechanical thrombectomy alone, the patient in Case 1 had significant improvement in abdominal pain. Follow-up CT demonstrated no residual SMV thrombosis and the patient continued to do well in long-term follow-up. With the addition of t-PA power-pulse spray to rheolytic mechanical thrombectomy, the patient in Case 2 with subacute SMV thrombosis dramatically improved postprocedure with resolution of abdominal pain. Follow-up imaging demonstrated patency to the SMV and partial resolution of thrombus. The patient continued to do well at 2-year follow-up. Adding t-PA power-pulse spray to rheolytic mechanical thrombectomy can provide benefit in a single setting versus mechanical thrombectomy alone and prevent the need for subsequent infusions of thrombolytic therapy. CT guidance is a useful alternative of localization for portal vein access via the transhepatic route that is nonoperator-dependent and helpful in the case of obese patients.

  1. Iliofemoral and iliocaval interventions in deep venous thrombosis

    International Nuclear Information System (INIS)

    Haage, P.; Guenther, R.W.

    2005-01-01

    Significant spontaneous thrombus disintegration in deep venous thrombosis (DVT) occurs very infrequently. On the contrary, these thrombi are prone to appositional growth and migration into the pulmonary arteries. The development of chronic venous insufficiency due to post-thrombotic syndrome is a frequent consequence of DVT. Therapeutic options in DVT include anticoagulation and recanalising procedures such as thrombolysis and thrombectomy. After appropriate indication assessment, the interventional radiologist can offer an efficacy-proven minimally-invasive vessel restitution approach by performing locoregional thrombolysis, pharmacomechanical therapy or, particularly in iliocaval thrombosis, mechanical thrombectomy. These methods not only serve to restitute of vessel patency, but also allow preserving venous valve function. In DVT with recurrent pulmonary embolism, retrievable filters with extended implantation duration can be deployed. In chronic proximal venous flow obstruction or in case of significant residual stenosis after thrombolysis, balloon angioplasty with stent implantation is the treatment modality of choice. Consequently, the radiologist can adopt an important role in the treatment of extensive venous disease. In this article, the treatment modalities concerning iliofemoral and iliocaval thrombosis are demonstrated and illustrated. (orig.)

  2. Iliofemoral and iliocaval interventions in deep venous thrombosis; Iliofemorale und iliocavale Interventionen bei tiefer Venenthrombose

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    2005-05-01

    Significant spontaneous thrombus disintegration in deep venous thrombosis (DVT) occurs very infrequently. On the contrary, these thrombi are prone to appositional growth and migration into the pulmonary arteries. The development of chronic venous insufficiency due to postthrombotic syndrome is a frequent consequence of DVT. Therapeutic options in DVT include anticoagulation and recanalising procedures such as thrombolysis and thrombectomy. After appropriate indication assessment, the interventional radiologist can offer an efficacy-proven minimally-invasive vessel restitution approach by performing locoregional thrombolysis, pharmacomechanical therapy or, particularly in iliocaval thrombosis, mechanical thrombectomy. These methods not only serve to restitute of vessel patency, but also allow preserving venous valve function. In DVT with recurrent pulmonary embolism, retrievable filters with extended implantation duration can be deployed. In chronic proximal venous flow obstruction or in case of significant residual stenosis after thrombolysis, balloon angioplasty with stent implantation is the treatment modality of choice. Consequently, the radiologist can adopt an important role in the treatment of extensive venous disease. In this article, the treatment modalities concerning iliofemoral and iliocaval thrombosis are demonstrated and illustrated. (orig.)

  3. t-PA power-pulse spray with rheolytic mechanical thrombectomy using cross-sectional image-guided portal vein access for single setting treatment of subacute superior mesenteric vein thrombosis

    Directory of Open Access Journals (Sweden)

    Mubin I Syed

    2018-01-01

    Full Text Available Background: Isolated superior mesenteric vein (SMV thrombosis is a rare but potentially fatal condition if untreated. Current treatments include transjugular or transhepatic approaches for rheolytic mechanical thrombectomy and subsequent infusions of thrombolytics. Tissue plasminogen activator (t-PA power-pulse spray can provide benefit in a single setting without thrombolytic infusions. Computed tomography (CT guidance for portal vein access is underutilized in this setting. Materials and Methods: Case 1 discusses acute SMV thrombosis treated with rheolytic mechanical thrombectomy alone using ultrasound guidance for portal vein access. Case 2 discusses subacute SMV thrombosis treated with the addition of t-PA power-pulse spray to the rheolytic mechanical thrombectomy, using CT guidance for portal vein access. Results: With rheolytic mechanical thrombectomy alone, the patient in Case 1 had significant improvement in abdominal pain. Follow-up CT demonstrated no residual SMV thrombosis and the patient continued to do well in long-term follow-up. With the addition of t-PA power-pulse spray to rheolytic mechanical thrombectomy, the patient in Case 2 with subacute SMV thrombosis dramatically improved postprocedure with resolution of abdominal pain. Follow-up imaging demonstrated patency to the SMV and partial resolution of thrombus. The patient continued to do well at 2-year follow-up. Conclusions: Adding t-PA power-pulse spray to rheolytic mechanical thrombectomy can provide benefit in a single setting versus mechanical thrombectomy alone and prevent the need for subsequent infusions of thrombolytic therapy. CT guidance is a useful alternative of localization for portal vein access via the transhepatic route that is nonoperator-dependent and helpful in the case of obese patients.

  4. S WAVE IN PULMONARY EMBOLISM, A NEW ECG SIGN TO AID THROMBOLYSIS

    Directory of Open Access Journals (Sweden)

    Thomas John

    2012-11-01

    Full Text Available Acute pulmonary embolism is a devastating disease that often leads to mortality . Previous investigators have found that thrombolysis reduces mortality in men but not significantly in women with pulmonary embolism. Many of the previous studies are with tenecteplase and alteplase. Here, we describe intra - venous thrombolysis with streptokinase in seven patients with pulmonary embolism who survived including two women. Further, we have one patient who had a new onset of S wave in lead I which subsequently disappeared after embolectomy. We also comment on the usefulness of shock sign in 2 deciding on thrombolysis .We propose a new sign for noninvasive assessment of need for thrombolysis in pulmonary embolism. New onset S wave in Lead I in pulmonary embolism can be used as a new sign for deciding the need for thrombolysis. When added to the shock sign it can be used in the emergency deparment to decide the need for thrombolysis. Further, there are no clear end points as to when to stop thrombolysis. In all 4 patients we switched to heparin when spontaneous bleeding or oozing started. In all 4 patients subsequent CT scans showed that the patient has mild to moderate resolution of the pulmonary embolism and patients remained stable and have been discharged and are under regular follow up. Hence we propose that bleeding can be used as an end point for thrombolysis in acute pulmonary embolism. We also describe a patient who had new onset S wave that disappeared after successful pulmonary embolectomy. Probably, the S wave is a marker of main pulmonary artery branch occlusions.

  5. Experience in using intravenous thrombolysis in ischemic stroke in Tatarstan

    Directory of Open Access Journals (Sweden)

    Dina Rustemovna Khasanova

    2011-01-01

    Full Text Available The paper describes experience with intravenous thrombolysis used in a few vascular centers of the Republic of Tatarstan in the past 5 years. Intravenous thrombolysis with alteplase (actilise was carried in 300 patients (188 men and 112 women aged 21 to 79 years (mean age 59.8±13.7 years who had ischemic stroke (IS. Significant positive changes (a neurological deficit decrease on the NIHSS score by ≥ 4 points were observed in 67.3% of cases; mortality was 6.7%. Hemorrhagic events as asymptomatic hemorrhagic transformations were found in 19.3% of cases with the neurological disorders being progressive in 4.6%. Recanalization of internal carotid artery occlusion was recorded only in 24.0% of the patients and that of occlusion of the proximal segments of the middle cerebral artery was in 50.1%. Examples of effective intravenous thrombolysis in IS in the carotid and vertebrobasilar beds are given. Whether intravenous thrombolysis can be more extensively used in IS is discussed.

  6. Ultrasound-enhanced thrombolysis using Definity as a cavitation nucleation agent.

    Science.gov (United States)

    Datta, Saurabh; Coussios, Constantin-C; Ammi, Azzdine Y; Mast, T Douglas; de Courten-Myers, Gabrielle M; Holland, Christy K

    2008-09-01

    Ultrasound has been shown previously to act synergistically with a thrombolytic agent, such as recombinant tissue plasminogen activator (rt-PA) to accelerate thrombolysis. In this in vitro study, a commercial contrast agent, Definity, was used to promote and sustain the nucleation of cavitation during pulsed ultrasound exposure at 120 kHz. Ultraharmonic signals, broadband emissions and harmonics of the fundamental were measured acoustically by using a focused hydrophone as a passive cavitation detector and used to quantify the level of cavitation activity. Human whole blood clots suspended in human plasma were exposed to a combination of rt-PA, Definity and ultrasound at a range of ultrasound peak-to-peak pressure amplitudes, which were selected to expose clots to various degrees of cavitation activity. Thrombolytic efficacy was determined by measuring clot mass loss before and after the treatment and correlated with the degree of cavitation activity. The penetration depth of rt-PA and plasminogen was also evaluated in the presence of cavitating microbubbles using a dual-antibody fluorescence imaging technique. The largest mass loss (26.2%) was observed for clots treated with 120-kHz ultrasound (0.32-MPa peak-to-peak pressure amplitude), rt-PA and stable cavitation nucleated by Definity. A significant correlation was observed between mass loss and ultraharmonic signals (r = 0.85, p cavitation activity. Stable cavitation activity plays an important role in enhancement of thrombolysis and can be monitored to evaluate the efficacy of thrombolytic treatment.

  7. Radiolysis of spray solutions

    International Nuclear Information System (INIS)

    Habersbergerova, A.; Janovsky, I.

    1985-01-01

    The factors were studied affecting thiosulfate radiolysis in the so-called spray solution for nuclear power plant containments. The reaction mechanism of primary radiolytic reactions leading to thiosulfate decomposition was studied using pulse radiolysis. Also measured was hydrazine loss in the irradiation of the bubbling solution intended for the capture of volatile chemical forms of radioiodine. Pulse radiolysis was used to study the kinetics of hydrazine reaction with elemental iodine. (author)

  8. Simulations of laser thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Chapyak, E.J.; Godwin, R.P.

    1999-03-01

    The authors have shown that bubble expansion and collapse near the interface between two materials with modest property differences produces jet-like interpenetration of the two materials. The bubble dynamics at a water-viscous fluid interface is compared with that at the interface of water with a weak elastic-plastic material. The authors find that, despite rather similar behavior during bubble growth and the initial portion of bubble collapse, the terminal jetting behavior is quite different, even in direction. The elastic-plastic properties chosen realistically represent real and surrogate thrombus. Simulations using the elastic-plastic model quantitatively agree with laboratory thrombolysis mass removal experiments. In the earlier simulations of laboratory experiments, walls have been remote so as to not effect the dynamics. Here the authors present two-dimensional simulations of thrombolysis with water over elastic-plastic surrogate thrombus in a geometry representative of the clinical situation. The calculations include thin cylindrical elastic walls with properties and dimensions appropriate for arteries. The presence of these artery walls does not substantially change the interface jetting predicted in unconfined simulations.

  9. Catheter-Directed Thrombolysis via Small Saphenous Veins for Treating Acute Deep Venous Thrombosis.

    Science.gov (United States)

    Yang, Bin; Xu, Xiao-Dong; Gao, Peng; Yu, Ji-Xiang; Li, Yu; Zhu, Ai-Dong; Meng, Ran-Ran

    2016-08-23

    BACKGROUND There is little data comparing catheter-directed thrombolysis (CDT) via small saphenous veins vs. systematic thrombolysis on complications and efficacy in acute deep venous thrombosis patients. The aim of our study was to compare the efficacy and safety of CDT via the small saphenous veins with systematic thrombolysis for patients with acute deep venous thrombosis (DVT). MATERIAL AND METHODS Sixty-six patients with acute DVT admitted from June 2012 to December 2013 were divided into 2 groups: 27 patients received systemic thrombolysis (ST group) and 39 patients received CDT via the small saphenous veins (CDT group). The thrombolysis efficiency, limb circumference differences, and complications such as post-thrombotic syndrome (PTS) in the 2 groups were recorded. RESULTS The angiograms demonstrated that all or part of the fresh thrombus was dissolved. There was a significant difference regarding thrombolysis efficiency between the CDT group and ST group (71.26% vs. 48.26%, P=0.001). In both groups the postoperative limb circumference changes were higher compared to the preoperative values. The differences between postoperative limb circumferences on postoperative days 7 and 14 were significantly higher in the CDT group than in the ST group (all Pdeep venous thrombosis.

  10. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-01-01

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p -2 ± 0.01 μm and 1.99 x 10 -2 ± 0.004 μm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  11. Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

    Energy Technology Data Exchange (ETDEWEB)

    Saettele, Megan R., E-mail: SaetteleM@umkc.edu [University of Missouri, Kansas City, Department of Radiology, Saint Luke' s Hospital (United States); Morelli, John N., E-mail: dr.john.morelli@gmail.com [Texas A and M University Health Science Center, Department of Radiology, Scott and White Clinic and Hospital (United States); Chesis, Paul; Wible, Brandt C. [University of Missouri, Kansas City, Department of Interventional Radiology, Saint Luke' s Hospital (United States)

    2013-12-15

    Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

  12. Epidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study.

    Science.gov (United States)

    Tunnell, J W; Nelson, J S; Torres, J H; Anvari, B

    2000-01-01

    Higher laser fluences than currently used in therapy (5-10 J/cm(2)) are expected to result in more effective treatment of port wine stain (PWS) birthmarks. However, higher incident fluences increase the risk of epidermal damage caused by absorption of light by melanin. Cryogen spray cooling offers an effective method to reduce epidermal injury during laser irradiation. The objective of this study was to determine whether high laser incident fluences (15-30 J/cm(2)) could be used while still protecting the epidermis in ex vivo human skin samples. Non-PWS skin from a human cadaver was irradiated with a Candela ScleroPlus Laser (lambda = 585 nm; pulse duration = 1.5 msec) by using various incident fluences (8-30 J/cm(2)) without and with cryogen spray cooling (refrigerant R-134a; spurt durations: 40-250 msec). Assessment of epidermal damage was based on histologic analysis. Relatively short spurt durations (40-100 msec) protected the epidermis for laser incident fluences comparable to current therapeutic levels (8-10 J/cm(2)). However, longer spurt durations (100-250 msec) increased the fluence threshold for epidermal damage by a factor of three (up to 30 J/cm(2)) in these ex vivo samples. Results of this ex vivo study show that epidermal protection from high laser incident fluences can be achieved by increasing the cryogen spurt duration immediately before pulsed laser exposure. Copyright 2000 Wiley-Liss, Inc.

  13. Intravenous thrombolysis in ischemic stroke with unknown onset using CT perfusion.

    Science.gov (United States)

    Cortijo, E; García-Bermejo, P; Calleja, A I; Pérez-Fernández, S; Gómez, R; del Monte, J M; Reyes, J; Arenillas, J F

    2014-03-01

    Acute ischemic stroke patients with unclear onset time presenting >4.5 h from last-seen-normal (LSN) time are considered late patients and excluded from i.v. thrombolysis. We aimed to evaluate whether this subgroup of patients is different from patients presenting >4.5 h from a witnessed onset, in terms of eligibility and response to computed tomography perfusion (CTP)-guided i.v. thrombolysis. We prospectively studied consecutive acute non-lacunar middle cerebral artery (MCA) ischemic stroke patients presenting >4.5 h from LSN. All patients underwent multimodal CT and were considered eligible for i.v. thrombolysis according to CTP criteria. Two patient groups were established based on the knowledge of the stroke onset time. We compared the proportion of candidates suitable for intravenous thrombolysis between both groups, and their outcome after thrombolytic therapy. Among 147 MCA ischemic stroke patients presenting >4.5 h from LSN, stroke onset was witnessed in 74 and unknown in 73. Thirty-seven (50%) patients in the first group and 32 (44%) in the second met CTP criteria for thrombolysis (P = 0.7). Baseline variables were comparable between both groups with the exception of age, which was higher in the unclear onset group. The rates of early neurological improvement (54.1% vs 46.9%), 2-h MCA recanalization (43.5% vs 37%), symptomatic hemorrhagic transformation (3% vs 0%) and good 3-month functional outcome (62.2% vs 56.3%) did not differ significantly between both groups. Delayed stroke patients with unknown onset time were no different than patients >4.5 h regarding eligibility and response to CTP-based i.v. thrombolysis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Generalized Safety and Efficacy of Simplified Intravenous Thrombolysis Treatment (SMART) Criteria in Acute Ischemic Stroke

    DEFF Research Database (Denmark)

    Sørensen, Sigrid B; Barazangi, Nobl; Chen, Charlene

    2016-01-01

    BACKGROUND: Common intravenous recombinant tissue plasminogen activator (IV rt-PA) exclusion criteria may substantially limit the use of thrombolysis. Preliminary data have shown that the SMART (Simplified Management of Acute stroke using Revised Treatment) criteria greatly expand patient...... eligibility by reducing thrombolysis exclusions, but they have not been assessed on a large scale. We evaluated the safety and efficacy of general adoption of SMART thrombolysis criteria to a large regional stroke network. METHODS: Retrospective analysis of consecutive patients who received IV thrombolysis...... within a regional stroke network was performed. Patients were divided into those receiving thrombolysis locally versus at an outside hospital. The primary outcome was modified Rankin Scale score (≤1) at discharge and the main safety outcome was symptomatic intracranial hemorrhage (sICH) rate. RESULTS...

  15. Intra-Arterial Thrombolysis for Deep Vein Thrombosis of the Lower Extremity: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moo Sang; Roh, Byung Suk [Dept. of Radiology, Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2011-09-15

    If the appropriate catheterization of the affected vein was not possible because of a narrowed or thrombus-filled venous lumen, successful treatment gets into trouble during catheter directed regional thrombolysis for treatment of deep vein thrombosis. In this situation, intra-arterial thrombolysis can be considered as an alternative treatment, but to the best of our knowledge, only two reports have been described. We present here cases of successful intra-arterial thrombolysis in patients with deep vein thrombosis.

  16. Trans-jugular catheter-directed thrombolysis combined with trans-dorsalis pedis vein thrombolysis for the treatment of deep venous thrombosis of the lower limbs

    International Nuclear Information System (INIS)

    Qian Jiesheng; Li Zhengran; Jiang Zaibo; Zhu Kangshun; Guan Shouhai; Zhou Bing; Xu Changmou; He Keke; Shang Hong

    2009-01-01

    Objective: To investigate the feasibility and efficacy of trans-jugular catheter-directed thrombolysis (CDT) together with trans-dorsalis pedis vein thrombolysis for the treatment of deep venous thrombosis (DVT) of the lower limbs. Methods: Jugular vein puncture, indwelling catheter and placement of IVC filter were performed in 18 patients with DVT (study group) followed by continuous trans-jugular CDT together with trans-dorsalis pedis vein thrombolysis. During the corresponding period, 16 patients with DVT (control group) received trans-dorsalis pedis vein thrombolysis only. Results: The thrombolytic time and total dose of urokinase in study group and control group were (6.6 ± 2.3) days, (5.52 ± 2.24) x 106 units and (8.2 ± 1.4) days, (7.00 ± 1.66) x 106 units respectively. The thrombolytic time and total dose of urokinase in study group were significantly lower than that in control group (P < 0.05). After the treatment the thigh circumference and calf circumference in study group showed a reduction of (4.6 ± 2.1) cm and (4.0 ± 2.1) cm respectively, which were (3.2 ± 1.7) cm and (2.7 ± 1.5) cm respectively in control group, the difference between two groups was statistically significant (P < 0.05). The complete patent of the veins was 66.7% in study group and 31.3% in control group, the difference between two groups was significant (P < 0.05). In four cases of the study group, the filters were withdrawn through the original puncture site after the thrombus was completely dissolved. Conclusion: Trans-jugular CDT combined with trans-dorsalis pedis vein thrombolysis is an effective and safe therapeutic technique for the treatment of deep venous thrombosis of the lower extremities, moreover, the filter can be taken back via the original puncture site when the thrombus is completely dissolved. (authors)

  17. Feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke

    International Nuclear Information System (INIS)

    Wang Wei; Li Cheng; Liu Zhensheng; Zhang Xinjiang; Zhou Longjiang; Yin Haiyan

    2010-01-01

    Objective: To assess the feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke. Methods: Six patients with acute cerebral infarction within 6 hours underwent intraarterial thrombolysis, in which arterial blood bypass was used. A 2.3 F microcatheter was advanced through the clot and two milliliters of contrast was injected beyond the clot that remained stagnant in the major branches. At this point, 20 ml of oxygenated blood from femoral artery was injected for 2 minutes through the microcatheter past the occluding clot. Then, conventional intraarterial thrombolysis, including fibrinolytic agents infusion and mechanical disruption, was performed. Intraarterial thrombolysis and oxygenated blood infusion alternated every 30 minutes. Results: Every patient received arterial blood bypass with average three times (from 1 to 5 times) in the process of the intraarterial thrombolysis, which cost (8.0 ± 3.2) min. Recanalization was achieved in all 6 patients, but minor subarachnoid hemorrhage developed in one patient. All the patients got favorable clinical outcome. The life conditions is excellent in 4 cases and good in 2 cases. Conclusions: Arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke might be feasible, which did not interfere with conventional intraarterial thrombolysis and prolong the operation time significantly but could protect ischemic penumbra. (authors)

  18. Deposition of Bacillus subtilis spores using an airbrush-spray or spots to study surface decontamination by pulsed light.

    Science.gov (United States)

    Levy, Caroline; Bornard, Isabelle; Carlin, Frédéric

    2011-02-01

    Microbial contamination on surfaces of food processing equipment is a major concern in industries. A new method to inoculate a single-cell layer (monolayer) of microorganisms onto polystyrene was developed, using a deposition with an airbrush. A homogeneous dispersion of Bacillus subtilis DSM 402 spores sprayed on the surface was observed using both plate count and scanning electron microscopy. No clusters were found, even with high spore concentrations (10(7) spores/inoculated surface). A monolayer of microorganisms was also obtained after deposition of 10 μL droplets containing 3×10(4) spores/spot on polystyrene disks, but not with a higher spore concentration. Pulsed light (PL) applied to monolayers of B. subtilis spores allowed log reductions higher than 6. As a consequence of clusters formation in spots of 10 μL containing more than 3×10(5) spores, log reductions obtained by PL were significantly lower. The comparative advantages of spot and spray depositions were discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Edaravone, a Synthetic Free Radical Scavenger, Enhances Alteplase-Mediated Thrombolysis

    Directory of Open Access Journals (Sweden)

    Kiyoshi Kikuchi

    2017-01-01

    Full Text Available The combination of alteplase, a recombinant tissue plasminogen activator, and edaravone, an antioxidant, reportedly enhances recanalization after acute ischemic stroke. We examined the influence of edaravone on the thrombolytic efficacy of alteplase by measuring thrombolysis using a newly developed microchip-based flow-chamber assay. Rat models of embolic cerebral ischemia were treated with either alteplase or alteplase-edaravone combination therapy. The combination therapy significantly reduced the infarct volume and improved neurological deficits. Human blood samples from healthy volunteers were exposed to edaravone, alteplase, or a combination of alteplase and edaravone or hydrogen peroxide. Whole blood was perfused over a collagen- and thromboplastin-coated microchip; capillary occlusion was monitored with a video microscope and flow-pressure sensor. The area under the curve (extent of thrombogenesis or thrombolysis at 30 minutes was 69.9% lower in the edaravone-alteplase- than alteplase-treated group. The thrombolytic effect of alteplase was significantly attenuated in the presence of hydrogen peroxide, suggesting that oxidative stress might hinder thrombolysis. D-dimers were measured to evaluate these effects in human platelet-poor plasma samples. Although hydrogen peroxide significantly decreased the elevation of D-dimers by alteplase, edaravone significantly inhibited the decrease. Edaravone enhances alteplase-mediated thrombolysis, likely by preventing oxidative stress, which inhibits fibrinolysis by alteplase in thrombi.

  20. Thrombolysis for acute ischaemic stroke with alteplase in an Asian population: results of the multicenter, multinational Safe Implementation of Thrombolysis in Stroke-Non-European Union World (SITS-NEW).

    Science.gov (United States)

    Rha, Joung-Ho; Shrivastava, Vasantha Padma; Wang, Yongjun; Lee, Kim En; Ahmed, Niaz; Bluhmki, Erich; Hermansson, Karin; Wahlgren, Nils

    2014-10-01

    Safe Implementation of Thrombolysis in Stroke-Non-European Union World was a multinational, prospective, open, monitored, observational study of intravenous alteplase as thrombolytic therapy in clinical practice. Safe Implementation of Thrombolysis in Stroke-Non-European Union World was required to assess the safety of alteplase in an Asian population by comparison with results from the European Safe Implementation of Thrombolysis in Stroke-Monitoring Study and pooled results from randomized controlled trials. To evaluate the efficacy and safety of intravenous alteplase (0·9 mg/kg) as thrombolytic therapy within three-hours of onset of acute ischaemic stroke in an Asian population. The 591 patients included were treated at 48 centers in four countries (South Korea, China, India, and Singapore) between 2006 and 2008. Primary outcomes were symptomatic (deterioration in National Institutes of Health Stroke Scale score ≥4 or death within the first 24 h) intracerebral haemorrhage type 2 22-36 h after the thrombolysis and mortality at three-month follow-up. The secondary outcome was functional independence (modified Rankin Scale score 0-2) at three-months. Results were compared with those from Safe Implementation of Thrombolysis in Stroke-Monitoring Study (n = 6483) and pooled results of patients (n = 415) who received intravenous alteplase (0·9 mg/kg) zero- to three-hours from onset of stroke symptoms in four randomized controlled trials (National Institute of Neurological Disorders and Stroke A and B, Altephase Thrombolysis for Acute Noninterventional Therapy in Ischaemic Stroke, and European Cooperative Acute Stroke Study II). Results are presented as Safe Implementation of Thrombolysis in Stroke-Non-European Union World vs. Safe Implementation of Thrombolysis in Stroke-Monitoring Study vs. pooled randomized controlled trials. Median age was 64 vs. 68 vs. 70 years, National Institutes of Health Stroke Scale score at baseline was 12 vs. 12 vs. 13

  1. Successful selective arterial thrombolysis in patient with acute abdominal thromboembolism

    Directory of Open Access Journals (Sweden)

    Christo Tsekov

    2016-06-01

    Full Text Available The paper reports successful thrombolysis conducted in 64 years old woman admitted to the clinic with clinical and angiographic data for acute surgical abdomen caused by acute tromboembolia of arteria mesenterica superior (AMS. The therapeutic approach required to undertake lifesaving decision on i.e. surgical vs. invasive treatment in conditions of emergency. Finally, it was decided to undertake invasive treatment with successful restoration of blood flow in the related artery. The patient was discharged from the clinic with considerable clinical improvement on the fifth day of her stay. The case report includes discussion on issues relating the consequence of the diagnostic and interventional procedures in such patients, opportunities for conducting emergency thrombolysis in acute embolia of AMS and preventive measures in patients with high tromboembolic risk. Keywords: Mesenterial circulation, Abdominal thromboembolism, Arterial thrombolysis

  2. Floating arterial thrombus related stroke treated by intravenous thrombolysis.

    Science.gov (United States)

    Vanacker, P; Cordier, M; Janbieh, J; Federau, C; Michel, P

    2014-01-01

    The effects of intravenous thrombolysis on floating thrombi in cervical and intracranial arteries of acute ischemic stroke patients are unknown. Similarly, the best prevention methods of early recurrences remain controversial. This study aimed to describe the clinical and radiological outcome of thrombolyzed strokes with floating thrombi. We retrospectively analyzed all thrombolyzed stroke patients in our institution between 2003 and 2010 with floating thrombi on acute CT-angiography before the intravenous thrombolysis. The floating thrombus was diagnosed if an elongated thrombus of at least 5 mm length, completely surrounded by contrast on supra-aortic neck or intracerebral arteries, was present on CT-angiography. Demographics, vascular risk factors, and comorbidities were recorded and stroke etiology was determined after a standardized workup. Repeat arterial imaging was performed by CTA at 24 h or before if clinical worsening was noted and then by Doppler and MRA during the first week and at four months. Of 409 thrombolyzed stroke patients undergoing acute CT Angiography, seven (1.7%) had a floating thrombus; of these seven, six had it in the anterior circulation. Demographics, risk factors and stroke severity of these patients were comparable to the other thrombolyzed patients. After intravenous thrombolysis, the floating thrombi resolved completely at 24 h in four of the patients, whereas one had an early recurrent stroke and one developed progressive worsening. One patient developed early occlusion of the carotid artery with floating thrombus and subsequently a TIA. The two patients with a stable floating thrombus had no clinical recurrences. In the literature, only one of four reported cases were found to have a thrombolysis-related early recurrence. Long-term outcome seemed similar in thrombolyzed patients with floating thrombus, despite a possible increase of very early recurrence. It remains to be established whether acute mechanical thrombectomy could be

  3. Early Recovery of Aphasia through Thrombolysis: The Significance of Spontaneous Speech.

    Science.gov (United States)

    Furlanis, Giovanni; Ridolfi, Mariana; Polverino, Paola; Menichelli, Alina; Caruso, Paola; Naccarato, Marcello; Sartori, Arianna; Torelli, Lucio; Pesavento, Valentina; Manganotti, Paolo

    2018-07-01

    Aphasia is one of the most devastating stroke-related consequences for social interaction and daily activities. Aphasia recovery in acute stroke depends on the degree of reperfusion after thrombolysis or thrombectomy. As aphasia assessment tests are often time-consuming for patients with acute stroke, physicians have been developing rapid and simple tests. The aim of our study is to evaluate the improvement of language functions in the earliest stage in patients treated with thrombolysis and in nontreated patients using our rapid screening test. Our study is a single-center prospective observational study conducted at the Stroke Unit of the University Medical Hospital of Trieste (January-December 2016). Patients treated with thrombolysis and nontreated patients underwent 3 aphasia assessments through our rapid screening test (at baseline, 24 hours, and 72 hours). The screening test assesses spontaneous speech, oral comprehension of words, reading aloud and comprehension of written words, oral comprehension of sentences, naming, repetition of words and a sentence, and writing words. The study included 40 patients: 18 patients treated with thrombolysis and 22 nontreated patients. Both groups improved over time. Among all language parameters, spontaneous speech was statistically significant between 24 and 72 hours (P value = .012), and between baseline and 72 hours (P value = .017). Our study demonstrates that patients treated with thrombolysis experience greater improvement in language than the nontreated patients. The difference between the 2 groups is increasingly evident over time. Moreover, spontaneous speech is the parameter marked by the greatest improvement. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Pregnancy after catheter-directed thrombolysis for acute iliofemoral deep venous thrombosis

    DEFF Research Database (Denmark)

    Jørgensen, M; Broholm, R; Bækgaard, N

    2013-01-01

    To assess the safety and efficacy of low-molecular-weight heparin (LMWH) in pregnancy and puerperium in women with previous acute iliofemoral deep venous thrombosis (DVT) treated with catheter-directed thrombolysis (CDT).......To assess the safety and efficacy of low-molecular-weight heparin (LMWH) in pregnancy and puerperium in women with previous acute iliofemoral deep venous thrombosis (DVT) treated with catheter-directed thrombolysis (CDT)....

  5. Safety and functional outcome of thrombolysis in dissection-related ischemic stroke: a meta-analysis of individual patient data.

    Science.gov (United States)

    Zinkstok, Sanne M; Vergouwen, Mervyn D I; Engelter, Stefan T; Lyrer, Philippe A; Bonati, Leo H; Arnold, Marcel; Mattle, Heinrich P; Fischer, Urs; Sarikaya, Hakan; Baumgartner, Ralf W; Georgiadis, Dimitrios; Odier, Céline; Michel, Patrik; Putaala, Jukka; Griebe, Martin; Wahlgren, Nils; Ahmed, Niaz; van Geloven, Nan; de Haan, Rob J; Nederkoorn, Paul J

    2011-09-01

    The safety and efficacy of thrombolysis in cervical artery dissection (CAD) are controversial. The aim of this meta-analysis was to pool all individual patient data and provide a valid estimate of safety and outcome of thrombolysis in CAD. We performed a systematic literature search on intravenous and intra-arterial thrombolysis in CAD. We calculated the rates of pooled symptomatic intracranial hemorrhage and mortality and indirectly compared them with matched controls from the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register. We applied multivariate regression models to identify predictors of excellent (modified Rankin Scale=0 to 1) and favorable (modified Rankin Scale=0 to 2) outcome. We obtained individual patient data of 180 patients from 14 retrospective series and 22 case reports. Patients were predominantly female (68%), with a mean±SD age of 46±11 years. Most patients presented with severe stroke (median National Institutes of Health Stroke Scale score=16). Treatment was intravenous thrombolysis in 67% and intra-arterial thrombolysis in 33%. Median follow-up was 3 months. The pooled symptomatic intracranial hemorrhage rate was 3.1% (95% CI, 1.3 to 7.2). Overall mortality was 8.1% (95% CI, 4.9 to 13.2), and 41.0% (95% CI, 31.4 to 51.4) had an excellent outcome. Stroke severity was a strong predictor of outcome. Overlapping confidence intervals of end points indicated no relevant differences with matched controls from the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register. Safety and outcome of thrombolysis in patients with CAD-related stroke appear similar to those for stroke from all causes. Based on our findings, thrombolysis should not be withheld in patients with CAD.

  6. Effection of percutaneous coronary intenvention compared with intravenous thrombolysis therapy of acute myocardial infarction

    International Nuclear Information System (INIS)

    Lu Jianhui; Hong Xiaosu; Xu Weiting

    2006-01-01

    Objective: To evaluate the curative effect of the two successful therapeatic methods on myocardial infarction in the acute and long-term stage: percutaneous coronary intenvention(PCI) and intravenous thrombolysis therapy. Methods: Fifty-six patients of acute myocardial infarction were studied. There was no record of heart failure occurence in the case history for all of them. We randomly assigned them to receive PCI or intravenous thrombolysis therapy, and all of them are treated successfully. Left ventricule ejection fraction (LVEF) and left ventricule end diastole diameter(LVEDD) measured by echocardiography were analyzed. Clinical information about death caused by cardial origin problems were collected and the mean survival days of the patients were 548.7 ± 48.9. Results: The total of 27 patients were assigned to undergo PCI and 29 patients received intravenous thrombolysis therapy. LVEF patients with PCI were 57.6% ± 2.3%, and patients with intravenous thrombolysis therapy were 49.9% ± 1.9%. There were significant difference between the two groups(P 0.5). 548.7 ± 48.9 days survival was accounted for 85.2% in the PCI group, and 79.3% in the intravenous thrombolysis therapy (P>0.5). Multivariate analysis showed that older age, LVEF, were related to 548.7 ± 48.9 days mortality. Conclusion: The results of this study show more acute stage benefit patients treated with PCI using bare stant than those treated with intravenous thrombolysis therapy; But it indicates that there is no more long-term survival for patients treated with PCI by using bare stant compared with those who received intravenous thrombolysis therapy in the patients with light or medium acute myocardial infarction. (authors)

  7. Immediate Catheter Directed Thrombolysis for Thromboembolic Stroke During Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    E. Fletcher

    Full Text Available : Background: Carotid artery endarterectomy (CEA is a common procedure undertaken by vascular surgeons with over 5,000 procedures performed annually worldwide. Published rates of perioperative stroke range from 1.3% to 6.3%. Case report: A case is presented in which on-table intra-cranial angiography and catheter directed thrombolysis were used for a thromboembolic occlusion of the distal internal carotid artery (ICA and proximal middle cerebral artery (MCA. An 83-year-old lady developed a dense right hemiparesis while undergoing a CEA under local anaesthetic (LA. Immediate re-exploration of the endarterectomy did not reveal technical error. Intraoperative duplex scanning of the internal carotid artery revealed no detectable diastolic flow. On-table angiogram showed complete occlusion of the distal ICA and proximal MCA. Catheter directed administration of TPA was undertaken. The entire ICA and MCA were completely clear on a completion angiogram. The patient made a full neurological recovery. Discussion and conclusion: Prompt diagnosis and treatment with intraoperative catheter directed thrombolysis can resolve thromboembolic occlusion of the ICA/MCA. It is argued that performing CEA under LA is useful for immediate recognition of perioperative stroke. Furthermore, the advantage is highlighted of vascular surgeons having both the resources and skillset to perform on-table angiography and thrombolysis. Keywords: Carotid endarterectomy, Stroke, Thrombolysis, Thromboembolus, Local anaesthetic

  8. Thrombolysis significantly reduces transient myocardial ischaemia following first acute myocardial infarction

    DEFF Research Database (Denmark)

    Mickley, H; Pless, P; Nielsen, J R

    1992-01-01

    In order to investigate whether thrombolysis affects residual myocardial ischaemia, we prospectively performed a predischarge maximal exercise test and early out-of-hospital ambulatory ST segment monitoring in 123 consecutive men surviving a first acute myocardial infarction (AMI). Seventy......-four patients fulfilled our criteria for thrombolysis, but only the last 35 patients included received thrombolytic therapy. As thrombolysis was not available in our Department at the start of the study, the first 39 patients included were conservatively treated (controls). No significant differences...... in baseline clinical characteristics were found between the two groups. In-hospital atrial fibrillation and digoxin therapy was more prevalent in controls (P less than 0.05). During exercise, thrombolysed patients reached a higher maximal work capacity compared with controls: 160 +/- 41 vs 139 +/- 34 W (P...

  9. On-demand production of uniform DT droplets using pulsed electrohydrodynamic spraying. Charged Particle Research Laboratory report No. 1-82

    International Nuclear Information System (INIS)

    Kim, K.; Gavrilovic, P.

    1982-04-01

    A technique suitable for on-demand production of uniform DT droplets is investigated using pulsed electrohydrodynamic (EHD) spraying. Liquid hydrogen is employed as the working liquid, into which charge is injected using a sharp tungsten needle raised to high voltage. By controlling this high voltage, the amount of charge injection required for disrupting the liquid surface into a smooth liquid jet of desired size is determined. For on-demand production of the liquid jet (which breaks up into uniform droplets), high voltage pulses of appropriate height and duration are applied to the charge injection electrode. Results obtained with liquid hydrogen and liquid nitrogen are presented. Considering the potential hazard and scarcity of tritium, the present technique may prove to be particularly useful when there is a need for filling ICF targets with a controlled amount of DT micropellets

  10. Should cerebral microbleeds on magnetic resonance imaging contraindicate thrombolysis in patients with ischaemic stroke?

    International Nuclear Information System (INIS)

    Smith, Kate

    2011-01-01

    Rationale: Cerebral microbleeds (CMBs) may be a marker for increased risk of symptomatic intracranial haemorrhage (SICH) following thrombolysis of patients with ischaemic stroke. This study aims to determine whether the risk of SICH in patients with CMBs is sufficient that thrombolysis should be withheld. Methodology: Systematic review, with literature searched using bibliographic databases and cross-referencing from relevant papers to identify papers meeting predefined criteria. Conclusions: Current research indicates that while risk of SICH may be slightly elevated in patients with CMBs who receive thrombolysis, it is outweighed by the potential benefits of thrombolysis. It is not clear whether large numbers, or particular patterns, of CMBs indicate significantly increased risk. Evidence was found of inconsistency in both the diagnosis and prevalence of CMBs in the studies. Further research should assess whether severe CMBs indicate a clinically significant risk, and investigate classification and epidemiology of CMBs.

  11. Can online benchmarking increase rates of thrombolysis? Data from the Austrian stroke unit registry.

    Science.gov (United States)

    Ferrari, Julia; Seyfang, Leonhard; Lang, Wilfried

    2013-09-01

    Despite its widespread availability and known safety and efficacy, a therapy with intravenous thrombolysis is still undergiven. We aimed to identify whether nationwide quality projects--like the stroke registry in Austria--as well as online benchmarking and predefined target values can increase rates of thrombolysis. Therefore, we assessed 6,394 out of 48,462 patients with ischemic stroke from the Austrian stroke registry (study period from March 2003 to December 2011) who had undergone thrombolysis treatment. We defined lower level and target values as quality parameters and evaluated whether or not these parameters could be achieved in the past years. We were able to show that rates of thrombolysis in Austria increased from 4.9% in 2003 to 18.3% in 2011. In a multivariate regression model, the main impact seen was the increase over the years [the OR ranges from 0.47 (95% CI 0.32-0.68) in 2003 to 2.51 (95% CI 2.20-2.87) in 2011). The predefined lower and target levels of thrombolysis were achieved at the majority of participating centers: in 2011 the lower value of 5% was achieved at all stroke units, and the target value of 15% was observed at 21 of 34 stroke units. We conclude that online benchmarking and the concept of defining target values as a tool for nationwide acute stroke care appeared to result in an increase in the rate of thrombolysis over the last few years while the variability between the stroke units has not yet been reduced.

  12. Patient Selection for Drip and Ship Thrombolysis in Acute Ischemic Stroke.

    Science.gov (United States)

    Lyerly, Michael J; Albright, Karen C; Boehme, Amelia K; Shahripour, Reza Bavarsad; Donnelly, John P; Houston, James T; Rawal, Pawan V; Kapoor, Niren; Alvi, Muhammad; Sisson, April; Alexandrov, Anne W; Alexandrov, Andrei V

    2015-07-01

    The drip and ship model is a method used to deliver thrombolysis to acute stroke patients in facilities lacking onsite neurology coverage. We sought to determine whether our drip and ship population differs from patients treated directly at our stroke center (direct presenters). We retrospectively reviewed consecutive patients who received thrombolysis at an outside facility with subsequent transfer to our center between 2009 and 2011. Patients received thrombolysis after telephone consultation with a stroke specialist. We examined demographics, vascular risk factors, laboratory values, and stroke severity in drip and ship patients compared with direct presenters. Ninety-six patients were identified who received thrombolysis by drip and ship compared with 212 direct presenters. The two groups did not differ with respect to sex, ethnicity, vascular risk factors, or admission glucose. The odds ratio (OR) of arriving at our hospital as a drip and ship for someone 80 years or older was 0.31 (95% confidence interval [CI] 0.15-0.61, P < 0.001). Only 21% of drip and ship patients were black versus 38% of direct presenters (OR 0.434, 95% CI 0.25-0.76, P = 0.004). Even after stratifying by age (<80 vs ≥80), a smaller proportion of drip and ship patients were black (OR 0.44, 95% CI 0.24-0.81, P = 0.008). Furthermore, we found that fewer black patients with severe strokes arrived by drip and ship (OR 0.33, 95% CI 0.11-0.98, P = 0.0028). Our study showed that a smaller proportion of blacks and older adults arrived at our center by the drip and ship model. This may reflect differences in how patients are selected for thrombolysis and transfer to a higher level of care.

  13. Current status of intravenous thrombolysis for acute ischemic stroke in Asia.

    Science.gov (United States)

    Sharma, Vijay K; Ng, Kay W P; Venketasubramanian, Narayanaswamy; Saqqur, Maher; Teoh, Hock L; Kaul, Subash; Srivastava, Padma M V; Sergentanis, Theodoris; Suwanwela, Nijasri; Nguyen, Thang H; Lawrence Wong, K S; Chan, Bernard P L

    2011-12-01

    Data regarding thrombolysis for acute ischemic stroke in Asia are scarce and only a small percentage of patients are thrombolysed. The dose of intravenous tissue plasminogen activator (IV-tPA) in Asia remains controversial. Case-controlled observation studies in Asia included only Japanese patients and suggested the clinical efficacy and safety of low-dose IV-tPA (0.6 mg/kg body weight; max 60 mg) comparable to standard dose (0.9 mg/kg body weight; max. 90 mg). Reduced treatment cost, lower symptomatic intracerebral hemorrhage risk and comparable efficacy encouraged many Asian centers to adopt low-dose or even variable-dose IV-tPA regimens. We evaluated various Asian thrombolysis studies and compared with SITS-MOST registry and NINDS trial. We included the published studies on acute ischemic stroke thrombolysis in Asia. Unadjusted relative risks and 95% Confidence intervals were calculated for each study. Pooled estimates from random effects models were used because the tests for heterogeneity were significant. We found only 18 publications regarding acute ischemic stroke thrombolysis in Asia that included total of 9300 patients. Owing to ethnic differences, stroke severity, small number of cases in individual reports, outcome measures and tPA dose regimes, it is difficult to compare these studies. Functional outcomes were almost similar (to Japanese studies) when lower-dose IV-tPA was used in non-Japanese populations across Asia. Interestingly, with standard dose IV-tPA, considerably better functional outcomes were observed, without increasing symptomatic intracerebral hemorrhage rates. Variable dose regimens of IV-tPA are used across Asia without any reliable or established evidence. Establishing a uniform IV-tPA regimen is essential since the rapid improvements in health-care facilities and public awareness are expected to increase the rates of thrombolysis in Asia. © 2011 The Authors. International Journal of Stroke © 2011 World Stroke Organization.

  14. Risk factors are different for deep and lobar remote hemorrhages after intravenous thrombolysis.

    Directory of Open Access Journals (Sweden)

    Luis Prats-Sanchez

    Full Text Available Remote parenchymal haemorrhage (rPH after intravenous thrombolysis is defined as hemorrhages that appear in brain regions without visible ischemic damage, remote from the area of ischemia causing the initial stroke symptom. The pathophysiology of rPH is not clear and may be explained by different underlying mechanisms. We hypothesized that rPH may have different risk factors according to the bleeding location. We report the variables that we found associated with deep and lobar rPH after intravenous thrombolysis.This is a descriptive study of patients with ischemic stroke who were treated with intravenous thrombolysis. These patients were included in a multicenter prospective registry. We collected demographic, clinical and radiological data. We evaluated the number and distribution of cerebral microbleeds (CMB from Magnetic Resonance Imaging. We excluded patients treated endovascularly, patients with parenchymal hemorrhage without concomitant rPH and stroke mimics. We compared the variables from patients with deep or lobar rPH with those with no intracranial hemorrhage.We studied 934 patients (mean age 73.9±12.6 years and 52.8% were men. We observed rPH in 34 patients (3.6%; 9 (0.9% were deep and 25 (2.7% lobar. No hemorrhage was observed in 900 (96.6% patients. Deep rPH were associated with hypertensive episodes within first 24 hours after intravenous thrombolysis (77.7% vs 23.3%, p1 CMB (30.7% vs 4.4%, p = 0.003, lobar CMB (53.8% vs 3.0%, p<0.001 and severe leukoaraiosis (76.9% vs 42%, p = 0.02.A high blood pressure within the first 24 hours after intravenous thrombolysis is associated with deep rPH, whereas lobar rPH are associated with imaging markers of amyloid deposition. Thus, our results suggest that deep and lobar rPH after intravenous thrombolysis may have different mechanisms.

  15. Predictors of Thrombolysis Administration in Mild Stroke: Florida-Puerto Rico Collaboration to Reduce Stroke Disparities.

    Science.gov (United States)

    Asdaghi, Negar; Wang, Kefeng; Ciliberti-Vargas, Maria A; Gutierrez, Carolina Marinovic; Koch, Sebastian; Gardener, Hannah; Dong, Chuanhui; Rose, David Z; Garcia, Enid J; Burgin, W Scott; Zevallos, Juan Carlos; Rundek, Tatjana; Sacco, Ralph L; Romano, Jose G

    2018-03-01

    Mild stroke is the most common cause for thrombolysis exclusion in patients acutely presenting to the hospital. Thrombolysis administration in this subgroup is highly variable among different clinicians and institutions. We aim to study the predictors of thrombolysis in patients with mild ischemic stroke in the FL-PR CReSD registry (Florida-Puerto Rico Collaboration to Reduce Stroke Disparities). Among 73 712 prospectively enrolled patients with a final diagnosis of ischemic stroke or TIA from January 2010 to April 2015, we identified 7746 cases with persistent neurological symptoms and National Institutes of Health Stroke Scale ≤5 who arrived within 4 hours of symptom onset. Multilevel logistic regression analysis with generalized estimating equations was used to identify independent predictors of thrombolytic administration in the subgroup of patients without contraindications to thrombolysis. We included 6826 cases (final diagnosis mild stroke, 74.6% and TIA, 25.4%). Median age was 72 (interquartile range, 21); 52.7% men, 70.3% white, 12.9% black, 16.8% Hispanic; and median National Institutes of Health Stroke Scale, 2 (interquartile range, 3). Patients who received thrombolysis (n=1281, 18.7%) were younger (68 versus 72 years), had less vascular risk factors (hypertension, diabetes mellitus, and dyslipidemia), had lower risk of prior vascular disease (myocardial infarction, peripheral vascular disease, and previous stroke), and had a higher presenting median National Institutes of Health Stroke Scale (4 versus 2). In the multilevel multivariable model, early hospital arrival (arrive by 0-2 hours versus ≥3.5 hours; odds ratio [OR], 8.16; 95% confidence interval [CI], 4.76-13.98), higher National Institutes of Health Stroke Scale (OR, 1.87; 95% CI, 1.77-1.98), aphasia at presentation (OR, 1.35; 95% CI, 1.12-1.62), faster door-to-computed tomography time (OR, 1.81; 95% CI, 1.53-2.15), and presenting to an academic hospital (OR, 2.02; 95% CI, 1.39-2.95) were

  16. Dimerized plasmin fragment D as a potential biomarker to predict successful catheter-directed thrombolysis therapy in acute deep vein thrombosis.

    Science.gov (United States)

    Luo, Chien-Ming; Wu, I-Hui; Chan, Chih-Yang; Chen, Yih-Sharng; Yang, Wei-Shiung; Wang, Shoei-Shen

    2015-10-01

    The value of dimerized plasmin fragment D in the clinical monitoring during the catheter-directed thrombolysis in patients with acute deep vein thrombosis is not known. Dimerized plasmin fragment D levels in 24 patients with acute deep vein thrombosis undergoing catheter-directed thrombolysis were prospectively evaluated. The plasma dimerized plasmin fragment D level was measured serially before and at every 12 h during catheter-directed thrombolysis for 24 h. Technical success was defined as restoration of patency and flow with less than 50% residual thrombus by surveillance rotational venography. Technical success was achieved in 79.2% (19 of 24) of the treated limbs after catheter-directed thrombolysis. In univariate analysis, there was significant elevation of the dimerized plasmin fragment D at 12th h after starting the catheter-directed thrombolysis (P fragment D to predict successful catheter-directed thrombolysis was determined as 18.4 µg/ml at the 12th h after starting the catheter-directed thrombolysis with sensitivity 0.8 and specificity 0.8 (P = 0.03). It was further validated in multivariate logistic regression analysis (odds ratio: 14.38; 95% CI: 1.22-169.20; P = 0.03). Catheter-directed thrombolysis is safe and effective for restoration of blood flow in patients with acute deep vein thrombosis. Dimerized plasmin fragment D value greater than 18.4 µg/ml at the 12th h after starting catheter-directed thrombolysis had a high predictive rate of greater than 50% lysis at the end of catheter-directed thrombolysis. © The Author(s) 2014.

  17. Two-compartmental population balance modeling of a pulsed spray fluidized bed granulation based on computational fluid dynamics (CFD) analysis.

    Science.gov (United States)

    Liu, Huolong; Li, Mingzhong

    2014-11-20

    In this work a two-compartmental population balance model (TCPBM) was proposed to model a pulsed top-spray fluidized bed granulation. The proposed TCPBM considered the spatially heterogeneous granulation mechanisms of the granule growth by dividing the granulator into two perfectly mixed zones of the wetting compartment and drying compartment, in which the aggregation mechanism was assumed in the wetting compartment and the breakage mechanism was considered in the drying compartment. The sizes of the wetting and drying compartments were constant in the TCPBM, in which 30% of the bed was the wetting compartment and 70% of the bed was the drying compartment. The exchange rate of particles between the wetting and drying compartments was determined by the details of the flow properties and distribution of particles predicted by the computational fluid dynamics (CFD) simulation. The experimental validation has shown that the proposed TCPBM can predict evolution of the granule size and distribution within the granulator under different binder spray operating conditions accurately. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Pulse induction heating

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A S; Kachanov, B Y; Kogan, B V

    1993-12-31

    Induction heating and three types of pulse processes were studied. It was found that in pulse processes the frequency and pulse duration of heat treatments do not remain constant. High frequency pulse heat treatments can be used on sprayed coatings; such treatments will result in stronger surfaces with no cracks. For induction hardening, the rate of specific power was 1 to 1.5 kW/sq.cm, for forging it was 0.2 to 0.3 kW/sq.cm and for melting it was 0.05 to 0.1 kW/sq.cm. The application of pulse heating will result in higher rates of specific power.

  19. Safety and Efficacy of Catheter Direct Thrombolysis in Management of Acute Iliofemoral Deep Vein Thrombosis: A Systematic Review.

    Science.gov (United States)

    Elbasty, Ahmed; Metcalf, James

    2017-12-01

    Catheter direct thrombolysis (CDT) has been shown to be an effective treatment for deep venous thrombosis. The objective of the review is to improve safety and efficacy of the CDT by using ward based protocol, better able to predict complications and treatment outcome through monitoring of haemostatic parameters and clinical observation during thrombolysis procedure. MEDLINE, EMBASE, CENTRAL and Web of Science were searched for all articles on deep venous thrombosis, thrombolysis and correlations of clinical events (bleeding, successful thrombolysis) during thrombolysis with hemostatic parameters to March 2016. The risk of bias in included studies was assessed by Cochrane Collaboration's tool and Cochrane Risk of Bias Assessment Tool: for Non-Randomized Studies of Interventions. Twenty-four studies were included in the review and we found that improving safety and efficacy of CDT by using ward based protocol depending on eight factors; strict patient selection criteria, types of fibrinolytic drugs, mode of fibrinolytic drug injection, biochemical markers monitoring (fibrinogen, D-dimer, activated partial thromboplastin time, plasminogen activator inhibitor-1), timing of intervention, usage of intermittent pneumatic calf, ward monitoring and thrombolysis imaging assessment (intravascular ultrasound). These factors may help to improve safety and efficacy by reducing total thrombolytic drug dosage and at the same time ensure successful lysis. There is a marked lack of randomized controlled trials discussing the safety and efficacy of catheter direct thrombolysis. CDT can be performed safely and efficiently in clinical ward, providing that careful nursing, biochemical monitoring, proper selection and mode of infusion of fibrinolytic drugs, usage of Intermittent pneumatic calf and adequate thrombolysis imaging assessment are ensured.

  20. Trends in C-Reactive Protein Levels Are Associated with Neurological Change Twenty-Four Hours after Thrombolysis for Acute Ischemic Stroke.

    Science.gov (United States)

    Gill, Dipender; Sivakumaran, Prasanthi; Wilding, Peter; Love, Madeleine; Veltkamp, Roland; Kar, Arindam

    2016-08-01

    Elevated inflammatory markers such as C-reactive protein (CRP) are associated with worse outcomes in patients thrombolysed for acute ischemic stroke (AIS). To investigate whether changes in CRP levels are associated with neurological change after thrombolysis for AIS. Retrospective analysis of a single-center database of consecutive thrombolysis cases for AIS from October 18, 2011, to June 15, 2015, inclusive. Multivariate regression analysis was used to investigate the relationship between change in CRP 12-24 hours after thrombolysis and change in NIHSS (National Institutes of Health Stroke Scale) score 24 hours after thrombolysis. The other potentially confounding predictor variables included in the model were CRP on admission and NIHSS score before thrombolysis. Complete data were available for 108 out of possible 435 eligible patients. Increases in CRP levels 12-24 hours after thrombolysis were negatively associated with reduction in NIHSS score 24 hours after thrombolysis (coefficient .08, 95% confidence interval .031-.129, P = .002). Thus, on average, for every 12.5 mg/L additional increase in CRP 12-24 hours after thrombolysis, NIHSS score at 24 hours improved by 1 point less. While it was previously known that elevated CRP levels are associated with worse outcomes in patients thrombolysed for AIS, the current work demonstrates that changes in CRP levels after thrombolysis also relate to neurological change, and thus may have scope for use as prognostic markers. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Management of Cavoatrial Deep Venous Thrombosis: Incorporating New Strategies

    Science.gov (United States)

    Zayed, Mohamed A.; De Silva, Gayan S.; Ramaswamy, Raja S.; Sanchez, Luis A.

    2017-01-01

    Cavoatrial deep venous thrombosis (DVT) is diagnosed with increasing prevalence. It can be managed medically with anticoagulation or with directed interventions aimed to efficiently reduce the thrombus burden within the target venous segment. The type of management chosen depends greatly on the etiology and chronicity of the thrombosis, existing patient comorbidities, and the patient's tolerance to anticoagulants and thrombolytic agents. In addition to traditional percutaneous catheter-based pharmacomechanical thrombolysis, other catheter-based suction thrombectomy techniques have emerged in recent years. Each therapeutic modality requires operator expertise and a coordinated care paradigm to facilitate successful outcomes. Open surgical thrombectomy is alternatively reserved for specific patient conditions, including intolerance of anticoagulation, failed catheter-based interventions, or acute emergencies. PMID:28265127

  2. Heat and mass transfer are in the interaction of multi-pulsed spray with vertical surfaces in the regime of evaporative cooling

    Science.gov (United States)

    Karpov, P. N.; Nazarov, A. D.; Serov, A. F.; Terekhov, V. I.

    2017-10-01

    Sprays with a periodic supply drop phase have great opportunities to control the processes of heat transfer. We can achieve optimal evaporative modes of cooling by changing the pulse duration and the repetition frequency while minimizing flow of the liquid phase. Experimental data of investigation of local heat transfer for poorly heated large surface obtained on the original stand with multi nozzle managed the irrigation system impact of the gas-droplet flow present in this work. Researches on the contribution to the intensification of spray options were conducted. Also the growth rate was integral and local heat. Information instantaneous distribution of the heat flux in the description of the processes have helped us. Managed to describe two basic modes of heat transfer: Mode “insular” foil cooling and thick foil with forming of streams. Capacitive sensors allow to monitor the dynamics of the foil thickness, the birth-belt flow, forming and the evolution of waves generated by “bombing” the surface with the droplets.

  3. Investigation of the temporal evolution and spatial variation of in-cylinder engine fuel spray characteristics

    International Nuclear Information System (INIS)

    Qin, Wenjin; Hung, David L.S.; Xu, Min

    2015-01-01

    Highlights: • POD quadruple decomposition can reconstruct spray structure into different parts. • Different quadruple POD parts reveal different levels of spay field intensity. • Large scale structure part dominates the CCV of the entire spray. • In-cylinder flow field has the strongest effect on CCV of spray structure. - Abstract: The proper orthogonal decomposition (POD) method is applied to analyze the pulsing spray characteristics of the fuel injection inside a four-valve optical spark-ignition direct-injection (SIDI) engine. The instantaneous spray structures are decomposed into four parts, namely the mean structure, large scale structure, transition structure and small scale structure, respectively, by using POD quadruple decomposition. The cycle-to-cycle variations (CCV) of the in-cylinder pulsing spray structure are examined separately based on the four parts. Analysis results indicate that the four parts have different characteristics, and each individual part represents a specific instantaneous spray structure. First, the mean part contains more than 90% of the total intensity of the spray field throughout the whole injection process. Moreover, the large scale structure part has the highest CCV level among all four parts, and it dominates the CCV of the entire spray field. The CCV of spray can be influenced by different engine operating conditions. In particular, the in-cylinder flow field has the strongest effect on the spray CCV. The varying motion of the in-cylinder flow field significantly influences the CCV of the large scale spray part, which in turn affects the CCV characteristics of the whole spray field

  4. An experimental methodology to quantify the spray cooling event at intermittent spray impact

    International Nuclear Information System (INIS)

    Moreira, Antonio L.N.; Carvalho, Joao; Panao, Miguel R.O.

    2007-01-01

    The present paper describes an experimental methodology devised to study spray cooling with multiple-intermittent sprays as those found in fuel injection systems of spark-ignition and diesel engines, or in dermatologic surgery applications. The spray characteristics and the surface thermal behaviour are measured by combining a two-component phase-Doppler anemometer with fast response surface thermocouples. The hardware allows simultaneous acquisition of Doppler and thermocouple signals which are processed in Matlab to estimate the time-varying heat flux and fluid-dynamic characteristics of the spray during impact. The time resolution of the acquisition system is limited by the data rate of validation of the phase-Doppler anemometer, but it has been shown to be accurate for the characterization of spray-cooling processes with short spurt durations for which the transient period of spray injection plays an important role. The measurements are processed in terms of the instantaneous heat fluxes, from which phase-average values of the boiling curves are obtained. Two of the characteristic parameters used in the thermal analysis of stationary spray cooling events, the critical heat flux (CHF) and Leidenfrost phenomenon, are then inferred in terms of operating conditions of the multiple-intermittent injections, such as the frequency, duration and pressure of injection. An integral method is suggested to describe the overall process of heat transfer, which accounts for the fluid-dynamic heterogeneities induced by multiple and successive droplet interactions within the area of spray impact. The method considers overall boiling curves dependant on the injection conditions and provides an empirical tool to characterize the heat transfer processes on the impact of multiple-intermittent sprays. The methodology is tested in a preliminary study of the effect of injection conditions on the heat removed by a fuel spray striking the back surface of the intake valve as in spark

  5. Recurrent Iliofemoral Venous Thrombosis in the Setting of May-Thurner Syndrome as the Presenting Symptom of Behcet's Disease.

    Science.gov (United States)

    Lakha, Sameer; Png, Chien Yi Maximilian; Chun, Kevin; Ting, Windsor

    2018-02-23

    Vascular manifestations including pulmonary artery aneurysms and venous thrombosis are seen in up to 14% of patients with Behcet's disease. We report a patient who had recurrent deep vein thrombosis (DVT) as the presenting symptom of Behcet's Disease. A 19-year-old male who presented with acute iliofemoral DVT, confirmed by intravascular ultrasound (IVUS) and venogram. May-Thurner syndrome was also observed. Repeated catheter-based pharmacomechanical thrombolysis, thrombectomy, and subsequent iliac vein stenting were performed. The patient was then discharged on rivaroxaban and aspirin. Five months later, the patient experienced left calf pain. In the interim, he had been diagnosed with Behcet's disease by a rheumatologist who was consulted due to oral ulcers and skin lesions and accordingly started on prednisone, colchicine, and azathioprine. At this time, IVUS and venogram revealed thrombotic occlusion of the previously placed stent. Tissue plasminogen activator was infused into the stent, and pharmacomechanical thrombectomy restored flow through the left iliac veins. Follow-up laboratory workup revealed that subtherapeutic azathioprine dosing, and after appropriate adjustment, the patient has been asymptomatic for 12 months. Acute refractory DVT is a possible presenting symptom of Behcet's disease, which may be complicated by May-Thurner syndrome. Such patients should receive therapeutic immunosuppression in addition to anticoagulation. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Hyperacute stroke patients and catheter thrombolysis therapy. Correlation between computed tomography perfusion maps and final infarction

    International Nuclear Information System (INIS)

    Naito, Yukari; Tanaka, Shigeko; Inoue, Yuichi; Ota, Shinsuke; Sakaki, Saburo; Kitagaki, Hajime

    2008-01-01

    We investigated the correlation between abnormal perfusion areas by computed tomography perfusion (CTP) study of hyperacute stroke patients and the final infarction areas after intraarterial catheter thrombolysis. CTP study using the box-modulation transfer function (box-MTF) method based on the deconvolution analysis method was performed in 22 hyperacute stroke patients. Ischemic lesions were immediately treated with catheter thrombolysis after CTP study. Among them, nine patients with middle cerebral artery (MCA) occlusion were investigated regarding correlations of the size of the prolonged mean transit time (MTT) area, the decreased cerebral blood volume (CBV) area, and the final infarction area. Using the box-MTF method, the prolonged MTT area was almost identical to the final infarction area in the case of catheter thrombolysis failure. The decreased CBV areas resulted in infarction or hemorrhage, irrespective of the outcome of recanalization after catheter thrombolysis. The prolonged MTT areas, detected by the box-MTF method of CTP in hyperacute stroke patients, included the area of true prolonged MTT and the tracer delay. The prolonged MTT area was almost identical to the final infarction area when recanalization failed. We believe that a tracer delay area also indicates infarction in cases of thrombolysis failure. (author)

  7. Catheter directed thrombolysis for deep vein thrombosis during the first trimester of pregnancy: two case report

    International Nuclear Information System (INIS)

    Kim, Kum Rae; Park, Won Kyu; Kim, Jae Woon; Kwun, Woo Hyung; Suh, Bo Yang; Park, Kyeong Seok

    2008-01-01

    Anticoagulation with heparin has been the standard management therapy of deep vein thrombosis during pregnancy. Pregnancy is generally considered as a contraindication for thrombolysis. However, anticoagulation therapy alone does not protect the limbs from post-thrombotic syndrome and venous valve insufficiency. Catheter-directed thrombolysis, combined with angioplasty and stenting, can remove the thrombus and restore patency of the veins, resulting in prevention of post-thrombotic syndrome and valve insufficiency. We report successful catheter-directed thrombolysis and stenting in two early gestation patients with a deep vein thrombosis of the left lower extremity

  8. Catheter directed thrombolysis for deep vein thrombosis during the first trimester of pregnancy: two case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kum Rae; Park, Won Kyu; Kim, Jae Woon; Kwun, Woo Hyung; Suh, Bo Yang [College of Medicine, Yeungnam University, Daegu (Korea, Republic of); Park, Kyeong Seok [Yeungnam University, Medical Center, Daegu (Korea, Republic of)

    2008-02-15

    Anticoagulation with heparin has been the standard management therapy of deep vein thrombosis during pregnancy. Pregnancy is generally considered as a contraindication for thrombolysis. However, anticoagulation therapy alone does not protect the limbs from post-thrombotic syndrome and venous valve insufficiency. Catheter-directed thrombolysis, combined with angioplasty and stenting, can remove the thrombus and restore patency of the veins, resulting in prevention of post-thrombotic syndrome and valve insufficiency. We report successful catheter-directed thrombolysis and stenting in two early gestation patients with a deep vein thrombosis of the left lower extremity.

  9. Successful thrombolysis of aortic prosthetic valve thrombosis during ...

    African Journals Online (AJOL)

    Successful thrombolysis of aortic prosthetic valve thrombosis during first trimester of pregnancy. A Shukla, AP Raval, R Shah. Abstract. Prosthetic heart valve thrombosis during pregnancy is life-threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we ...

  10. NeuroSPECT assessment of ischemic penumbra in acute brain infarct: control of intra-arterial thrombolysis

    International Nuclear Information System (INIS)

    Mena, F.J.; Mena, I.; Contreras, I.; Soto, F.; Ducci, H.; Fruns, M.

    2002-01-01

    Introduction: Brain infarct is the most common cause of incapacity in adults, the second cause of dementia and the 2nd or 3rd cause of death. Acute brain infarct is a medical emergency potentially reversible if treated with thrombolysis in the first hours of evolution. Thrombolysis is now an approved and efficacious method of treatment for acute ischemic stroke. During the first 3 hours of evolution, intravenous administration of plasminogen activator (tPA) can be performed. The window of time of treatment is expanded to 6 hours with the intra-arterial super selective route for thrombolysis. Aim: The aim of this study was to define levels of reversible ischemia (penumbra) demonstrated by statistically evaluated HMPAO Tc99m NeuroSPECT performed before and after intra-arterial thrombolysis in the treatment of acute infarct. Materials and Methods: 21 patients were treated during the first 6 hours of evolution of an acute ischemic stroke with the following protocol. 1) Admission, and complete neurological evaluation. 2) Brain CT scan to rule hemorrhage or established infarct. 3) I.V injection of 1100MBq Tc99m HMPAO (Ceretec tm) 4) Conventional cerebral angiography and intra-arterial thrombolysis and/or angioplasty/stenting if necessary. 5) NeuroSPECT assessment of ischemic penumbra. 6) Control at 24 hrs with NeuroSPECT. NeuroSPECT image acquisition is performed immediately following arterial thrombolysis with a dual Head Camera, SHR collimators and conventional protocol. Image processing was performed using the Segami Software, as previously reported in Alasbimn Journal2 (7): April 2000. http://www.alasbimnjournal.cl. The analysis consists of 1) Tallairach brain volume normalization. 2) Voxel by voxel comparison of the individual brain cortex uptake normalized to the maximum in the cortex with a normal database of 24 age-matched controls. Results: The results are expressed in standard deviations (S.D.) below the normal mean. Normal mean is 72% + 6. Only voxels between

  11. The free-radical scavenger edaravone accelerates thrombolysis with alteplase in an experimental thrombosis model.

    Science.gov (United States)

    Yamashita, Tsutomu; Sato, Takumi; Sakamoto, Kumi; Ishii, Hiromitsu; Yamamoto, Junichiro

    2015-06-01

    Reperfusion injury after thrombolytic therapy can have adverse neurologic effects. The free-radical scavenger edaravone is used in combination with the recombinant tissue plasminogen activator alteplase to treat acute ischemic stroke. However, basic investigations of this combination use remain inadequate. Here, we used an in vivo model to investigate the effects of edaravone on alteplase-induced thrombolysis. Thrombolysis was evaluated by using a He-Ne-laser-induced thrombosis model in rat mesenteric microvessels. Changes in thrombus volume were analyzed with the image analysis software Image-Pro Plus (Media Cybernetics, USA). There were three experimental groups (placebo, alteplase 0.6 mg/kg, alteplase 0.6 mg/kg + edaravone 10.5 mg/kg). Sequential changes (0 to 60 min) in thrombus volume were compared by using a relative optical density method that we had used previously. In the placebo group, the thrombus volume at 60 min, reflecting the extent of thrombolysis, was 97.2% ± 5.7% of the initial value. In the alteplase group, thrombus volume decreased to 70.7% ± 4.1% (Pedaravone group, thrombus volume decreased to 66.9% ± 7.2% (Pedaravone accelerates thrombolysis by alteplase. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The Safety of Using High Frequency, Low Intensity Ultrasound to Enhance Thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita

    2006-01-01

    The EKOS Ultrasound Infusion Systems (EKOS Corporation, Bothell, WA) use high frequency, low intensity ultrasound to accelerate thrombolysis by enhancing clot permeability and lytic drug penetration into thrombus. These systems are designed to provide efficacious catheter-directed treatment for the management of stroke, peripheral arterial occlusion and deep vein thrombosis. The in vitro and in vivo results of investigating the stability of therapeutic and diagnostic compounds used in combination with EKOS devices, the potential for adverse biological effects and the clot fragmentation confirmed the safety of EKOS ultrasound infusion systems in thrombolysis treatment

  13. Nutritional Profile and Carbohydrate Characterization of Spray-Dried Lentil, Pea and Chickpea Ingredients

    Directory of Open Access Journals (Sweden)

    Susan M. Tosh

    2013-07-01

    Full Text Available Although many consumers know that pulses are nutritious, long preparation times are frequently a barrier to consumption of lentils, dried peas and chickpeas. Therefore, a product has been developed which can be used as an ingredient in a wide variety of dishes without presoaking or precooking. Dried green peas, chickpeas or lentils were soaked, cooked, homogenized and spray-dried. Proximate analyses were conducted on the pulse powders and compared to an instant mashed potato product. Because the health benefits of pulses may be due in part to their carbohydrate content, a detailed carbohydrate analysis was carried out on the pulse powders. Pulse powders were higher in protein and total dietary fibre and lower in starch than potato flakes. After processing, the pulse powders maintained appreciable amounts of resistant starch (4.4%–5.2%. Total dietary fibre was higher in chickpeas and peas (26.2% and 27.1% respectively than lentils (21.9%, whereas lentils had the highest protein content (22.7%. Pulse carbohydrates were rich in glucose, arabinose, galactose and uronic acids. Stachyose, a fermentable fibre, was the most abundant oligosaccharide, making up 1.5%–2.4% of the dried pulse powders. Spray-drying of cooked, homogenized pulses produces an easy to use ingredient with strong nutritional profile.

  14. Synthesis of electrochromic vanadium oxide by pulsed spray pyrolysis technique and its properties

    International Nuclear Information System (INIS)

    Patil, C E; Tarwal, N L; Shinde, P S; Patil, P S; Deshmukh, H P

    2009-01-01

    A new improved pulsed spray pyrolysis technique (PSPT) was employed to deposit a vanadium oxide (V 2 O 5 ) thin film from a methanolic vanadium chloride precursor onto glass and conducting F : SnO 2 coated glass substrates. The structural, morphological, electrical, optical and spectroscopic properties of the film deposited at 573 K were studied. Infrared spectroscopy and x-ray diffraction confirmed the presence of the V 2 O 5 phase. The V 2 O 5 film (thickness ∼118 nm) is polycrystalline with a tetragonal crystal structure. Scanning electron microscopy reveals compact granular morphology consisting of ∼80-100 nm size grains. The film is transparent in the visible region (average %T ∼70%) with an optical band gap energy of 2.47 eV involving both direct and indirect optical transitions. The room temperature electrical resistivity (conductivity) of the film is 1.6 x 10 8 Ω cm (6.25 x 10 -9 S cm -1 ) with an activation energy of 0.67 eV in the temperature range 300-550 K. It exhibited cathodic electrochromism in the lithium containing electrolyte (0.5 M LiClO 4 + propylene carbonate).

  15. Coronary angiography after successful thrombolysis - Is the recommended time interval of 24h an important issue?

    Science.gov (United States)

    Costa, Cátia; Durão, David; Belo, Adriana; Domingues, Kevin; Santos, Beatriz; Leal, Margarida

    2016-11-01

    Percutaneous coronary intervention (PCI) is currently considered the gold-standard treatment of acute coronary syndromes with ST-segment elevation (STEMI). However, this is not the reality of many European centers, where thrombolysis is performed as primary therapy. To determine, in a STEMI population that performed successful fibrinolytic treatment, if the performance of coronary angiography after the first 24h was associated with more hospital complications, including higher mortality, compared with its performance in the recommended time. Retrospective study, including 1065 patients with STEMI, who performed successful thrombolysis. The population was divided in three groups: A, patients who didn't undergo coronary angiography after successful thrombolysis (n=278; 26.1%); B, patients who underwent coronary angiography in the first 24h after successful thrombolysis (n=127; 11.9%); and C, patients who underwent angiography after the first 24h (n=660; 62.0%). Groups were compared regarding their characteristics and in-hospital complications. Groups B and C had more male patients and had younger patients than group A. Group A presented higher Killip classes at admission, more severe left ventricle dysfunction and a higher number of complications during hospitalization. Logistic regression revealed that: 1) the non-performance of coronary angiography after thrombolysis was an independent predictor of in-hospital mortality; and 2) the performance of angiography after the recommended time wasn't associated with higher mortality. Coronary angiography after thrombolysis constitutes an important strategy, whose non-performance carries worse prognosis. The time interval currently recommended of 24h seems clinically acceptable; however, its realization outside the recommended time doesn't seem to lead to higher mortality. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Catheter-directed thrombolysis of below-knee deep venous thrombosis of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Sohn, Young Jun; Heo, Eun A; Cho, Hyun Sun; Park, Seong Hoon; Lee, Young Hwan [Wonkwang University Hospital, Iksan (Korea, Republic of)

    2008-02-15

    To evaluate the technical feasibility and clinical efficacy of the use of local thrombolysis for below-knee deep vein thrombosis (DVT). From a population of 41 patients with a lower extremity DVT, the prospective clinical trial included 11 patients (7 female, 4 male, average age 61.4 years) treated with catheter-directed thrombolysis with urokinase for below-knee DVT. After removal of the proximal ilofemoral DVT, additional interventional procedures to remove the residual thrombosis and restore the venous flow from the below-knee vein were performed in cases of continuous occlusion of venous flow from the popliteal and tibial veins. Under ultrasound (US) guidance, catheter-directed thrombolysis with urokinase was performed through the ipsilateral popliteal vein. After administration of oral anticoagulation therapy, CT and venography were performed to identify patency and the presence of a recurrent thrombosis. Successful removal of the thrombus and restoration of venous flow were achieved in all of the patients (100%). Restoration of flow with a residual thrombus occurred in one case. Focal venous stenosis was discovered in four cases. The duration of urokinase infusion was 1-4 days (average 2.36 days), which was considered long. For 15.2 months, the venous lumen of all cases was preserved without a recurrent thrombosis. Catheter-directed thrombolysis is an effective procedure for recanalization of below-knee DVT in patients with a lower extremity DVT.

  17. Catheter-directed thrombolysis of below-knee deep venous thrombosis of the lower extremities

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Sohn, Young Jun; Heo, Eun A; Cho, Hyun Sun; Park, Seong Hoon; Lee, Young Hwan

    2008-01-01

    To evaluate the technical feasibility and clinical efficacy of the use of local thrombolysis for below-knee deep vein thrombosis (DVT). From a population of 41 patients with a lower extremity DVT, the prospective clinical trial included 11 patients (7 female, 4 male, average age 61.4 years) treated with catheter-directed thrombolysis with urokinase for below-knee DVT. After removal of the proximal ilofemoral DVT, additional interventional procedures to remove the residual thrombosis and restore the venous flow from the below-knee vein were performed in cases of continuous occlusion of venous flow from the popliteal and tibial veins. Under ultrasound (US) guidance, catheter-directed thrombolysis with urokinase was performed through the ipsilateral popliteal vein. After administration of oral anticoagulation therapy, CT and venography were performed to identify patency and the presence of a recurrent thrombosis. Successful removal of the thrombus and restoration of venous flow were achieved in all of the patients (100%). Restoration of flow with a residual thrombus occurred in one case. Focal venous stenosis was discovered in four cases. The duration of urokinase infusion was 1-4 days (average 2.36 days), which was considered long. For 15.2 months, the venous lumen of all cases was preserved without a recurrent thrombosis. Catheter-directed thrombolysis is an effective procedure for recanalization of below-knee DVT in patients with a lower extremity DVT

  18. Ultrasound Thrombolysis in Hemodialysis Access: In Vitro Investigation

    International Nuclear Information System (INIS)

    Wildberger, Joachim Ernst; Schmitz-Rode, Thomas; Haage, Patrick; Pfeffer, Joachim; Ruebben, Alexander; Guenther, Rolf W.

    2001-01-01

    Purpose: To evaluate the effectiveness of ultrasound thrombolysis in occluded hemodialysis access shunts using an in vitro model.Methods: Thrombosed hemodialysis accesses were simulated by clotted bovine blood in a flow model (silicone tubing; inner diameters 4, 6, and 9 mm). After retrograde and antegrade sheath placement (7 Fr), mechanical thrombolysis was performed using an ultrasound probe (Acolysis, Angiosonics, Morrisville, NC, USA). The tip of the device measured 2.2 mm in diameter. During sonication, the catheter was moved slowly back and forth using an over-the-wire system. Thirty complete occlusions [tubing diameters 4 mm (n = 12), 6 mm (n = 12), 9 mm (n = 6)] were treated. Initial thrombus weights were 3.5 (± 0.76) g, 7.7 (± 1.74) g, and 19.4 (± 2.27) g for the three diameters. Maximum sonication time was 15 min for each probe.Results: With this device, we were able to restore a continuous lumen in all 12 occluded 4∼mm silicone tubes. No wall-adherent thrombi remained after sonication for 3.5-9.6 min. In hemodialysis access models with diameters of 6 mm, thrombus fragments persisted in 25% (3/12 accesses). These were located in the medial portion of the access loop and near to the puncture sites. However, flow was re-established after 5.0-13.0 min of treatment in all settings. Mechanical dissolution of thrombus material failed in five of six access models with diameters of 9 mm, even though ultrasound energy was applied for the maximum of 15 min.Conclusion: In a clotted hemodialysis shunt model, successful ultrasound thrombolysis was limited to small access diameters and small amounts of thrombus

  19. Laser treatment of plasma sprayed HA coatings

    NARCIS (Netherlands)

    Khor, KA; Vreeling, A; Dong, ZL; Cheang, P

    1999-01-01

    Laser treatment was conducted on plasma sprayed hydroxyapatite (HA) coatings using a Nd-YAG pulse laser. Various laser parameters were investigated. The results showed that the HA surface melted when an energy level of greater than or equal to 2 J and a spot size of 2 mm was employed during

  20. Nursing care of catheter-directed thrombolysis therapy for acute arterial embolism of lower extremities

    International Nuclear Information System (INIS)

    Li Yan; Ge Jingping; Gu Jianping

    2011-01-01

    Objective: To discuss the clinical effect of nursing intervention for interventional catheter-directed thrombolysis therapy in patients with acute arterial embolism of lower extremities. Methods: The experience of nursing care for 48 cases with acute arterial embolism of lower extremities which was treated with interventional catheter-directed thrombolysis was retrospectively analyzed. Results: With the help of active nursing care and rational treatment the occluded arteries were completely reopened in 40 cases and partially reopened in 8 cases. Complete relief from the clinical symptoms was obtained in 42 cases and partial remission was seen in 6 cases. Conclusion: For getting a complete recovery and improving living quality after catheter-directed thrombolysis in patients with acute arterial embolism of lower extremities, the key points are sufficient preoperative preparation, perioperative painstaking nursing care as well as postoperative correct guidance of exercise program. (authors)

  1. Thrombolysis in Postoperative Stroke.

    Science.gov (United States)

    Voelkel, Nicolas; Hubert, Nikolai Dominik; Backhaus, Roland; Haberl, Roman Ludwig; Hubert, Gordian Jan

    2017-11-01

    Intravenous thrombolysis (IVT) is beneficial in reducing disability in selected patients with acute ischemic stroke. There are numerous contraindications to IVT. One is recent surgery. The aim of this study was to analyze the safety of IVT in patients with postoperative stroke. Data of consecutive IVT patients from the Telemedical Project for Integrative Stroke Care thrombolysis registry (February 2003 to October 2014; n=4848) were retrospectively searched for keywords indicating preceding surgery. Patients were included if surgery was performed within the last 90 days before stroke. The primary outcome was defined as surgical site hemorrhage. Subgroups with major/minor surgery and recent/nonrecent surgery (within 10 days before IVT) were analyzed separately. One hundred thirty-four patients underwent surgical intervention before IVT. Surgery had been performed recently (days 1-10) in 49 (37%) and nonrecently (days 11-90) in 85 patients (63%). In 86 patients (64%), surgery was classified as major, and in 48 (36%) as minor. Nine patients (7%) developed surgical site hemorrhage after IVT, of whom 4 (3%) were serious, but none was fatal. One fatal bleeding occurred remotely from surgical area. Rate of surgical site hemorrhage was significantly higher in recent than in nonrecent surgery (14.3% versus 2.4%, respectively, odds ratio adjusted 10.73; 95% confidence interval, 1.88-61.27). Difference between patients with major and minor surgeries was less distinct (8.1% and 4.2%, respectively; odds ratio adjusted 4.03; 95% confidence interval, 0.65-25.04). Overall in-hospital mortality was 8.2%. Intracranial hemorrhage occurred in 9.7% and was asymptomatic in all cases. IVT may be administered safely in postoperative patients as off-label use after appropriate risk-benefit assessment. However, bleeding risk in surgical area should be taken into account particularly in patients who have undergone surgery shortly before stroke onset. © 2017 American Heart Association, Inc.

  2. Bilateral catheter-directed thrombolysis in a patient with deep venous thrombosis caused by a hypoplastic inferior vena cava

    NARCIS (Netherlands)

    Sloot, S.; Van Nierop, J.; Kootstra, J. J.; Wittens, C.; Fritschy, W. M.

    Introduction Deep venous thrombosis treatment using catheter-directed thrombolysis is advocated over systemic thrombolysis because it reduces bleeding complications. With the development of a catheter that combines ultrasound vibrations and the local delivering of thrombolytics, new and safer

  3. Wind tunnel measurement of spray drift from on-off controlled sprayer nozzles

    DEFF Research Database (Denmark)

    Lund, Ivar; Jensen, Peter Kryger; Miller, Paul

    wide surface area with a length of 200 mm. The test was conducted in the wind tunnel at Silsoe Spray Applications Unit in the UK. The measurements consisted of two test series; airborne drift was collected on polyethylene lines more than 375 mm away from the centerline of the nozzle and ground deposits...... and arranged to deliver a pulse of spray using the WeedSeeker valve. The tests were conducted to determine accumulated spray deposit at different crosswind and forward speeds. In general, the deposits, especially those measured downwind close to the target zone showed significant increase as the crosswind......Sensor-based precision weed control system at a high resolution requires a high spray application accuracy to keep the spray in a small target zone. The objective of this research was to investigate the target accuracy and spray drift from individual controlled sprayer nozzles targeting a 250 mm...

  4. Thrombolysis for acute lower limb arterial embolism in patients with recent cerebral embolism

    International Nuclear Information System (INIS)

    Si Tongguo; Guo Zhi

    2008-01-01

    Objective: To assess the feasibility and efficacy of catheter-directed thrombolysis with recombinant tissue plasminogen activator (rt-PA)for acute limb embolism in patients with recent cerebral embolism. Methods: Eight patients with atrial fibrillation history happened to suffer acute limb embolism after recent cerebral embolism. The affected arteries included 2 left common iliac arteries, 4 femoral arteries (3 left, 1 right), 2 right popliteal arteries. Catheter-directed thrombolysis with rt-PA was applied with bolus administration plus continuous perfusion. Percutaneous transluminal angioplasty with balloon dilatation was applied in 3 patients, and one stent placement in one patient. Results: The mean duration of continuous perfusion was 3.6 hours and the mean dose of rt-PA administered was 23.6 mg (range, 20-28 mg)with complete recanalization rate of 100%. Clinical complete relief rate was 7/8 with one patient suffering from rest pain due to distal occlusion of anterior/posterior tibial artery. The complications included hematoma at puncture site (6/8), bleeding around the vascular sheath (2/8)and hematuria (1/8). NO intracerebral hemorrhage was found on CT scans after the thrombolysis. During follow up of 3-6 months, no recurrent embolism or thrombosis occurred in the limbs except one patient with recurrent cerebral embolism and died. Conclusions: Catheter-directed thrombolysis with rt-PA is probably to be a safe and effective method for acute limb embolism in patients with recent cerebral embolism and atrial fibrillation history. (authors)

  5. Idarucizumab in Three Patients Needing Urgent Surgical Intervention and One Case of Intravenous Thrombolysis in Ischaemic Stroke

    Directory of Open Access Journals (Sweden)

    Fredrik Andreas von Wowern

    2017-05-01

    Full Text Available Objective: To describe the benefits of reversal of the anticoagulation effects of dabigatran etexilate in patients requiring urgent surgery or thrombolysis for ischaemic stroke. Materials and methods: Four patients, treated with dabigatran etexilate and presenting with cholecystitis, tibial fracture, lower limb ischaemia and ischaemic stroke, respectively. Results: Administration of idarucizumab normalized bleeding parameters and provided safe conditions for surgery and, in one case, successful thrombolysis of an ischaemic stroke. Conclusion: The introduction of an effective reversal agent for dabigatran etexilate allows physicians perform surgery under conditions of normal coagulation and permits thrombolysis in patients with ischaemic stroke despite being treated with dabigatran etexilate.

  6. Bioconjugation of recombinant tissue plasminogen activator to magnetic nanocarriers for targeted thrombolysis

    Directory of Open Access Journals (Sweden)

    Yang HW

    2012-10-01

    Full Text Available Hung-Wei Yang,1,* Mu-Yi Hua,1,* Kun-Ju Lin,2,* Shiaw-Pyng Wey,3 Rung-Ywan Tsai,4 Siao-Yun Wu,5 Yi-Ching Lu,5 Hao-Li Liu,6 Tony Wu,7 Yunn-Hwa Ma5 1Chang Gung Molecular Medicine Research Center, Department of Chemical and Materials Engineering, 2Molecular Imaging Center, Department of Nuclear Medicine, Chang Gung Memorial Hospital, Kuei-Shan, Tao-Yuan, Taiwan, Republic of China; 3Department of Medical Imaging and Radiological Sciences, 4Electronics and Optoelectronics Research Laboratories, Industrial Technology Research Institute, Hsin-chu, Taiwan, Republic of China; 5Department of Physiology and Pharmacology and Healthy Aging Research Center, 6Department of Electrical Engineering, Chang Gung University, Kuei-Shan, Tao-Yuan, Taiwan, Republic of China; 7Department of Neurology, Chang Gung University College of Medicine and Memorial Hospital, Tao-Yuan, Taiwan, Republic of China*These authors contributed equally to this workAbstract: Low-toxicity magnetic nanocarriers (MNCs composed of a shell of poly [aniline-co-N-(1-one-butyric acid aniline] over a Fe3O4 magnetic nanoparticle core were developed to carry recombinant tissue plasminogen activator (rtPA in MNC-rtPA for targeted thrombolysis. With an average diameter of 14.8 nm, the MNCs exerted superparamagnetic properties. Up to 276 µg of active rtPA was immobilized per mg of MNCs, and the stability of the immobilized rtPA was greatly improved during storage at 4°C and 25°C. In vitro thrombolysis testing with a tubing system demonstrated that magnet-guided MNC-rtPA showed significantly improved thrombolysis compared with free rtPA and reduced the clot lysis time from 39.2 ± 3.2 minutes to 10.8 ± 4.2 minutes. In addition, magnet-guided MNC-rtPA at 20% of the regular rtPA dose restored blood flow within 15–25 minutes of treatment in a rat embolism model without triggering hematological toxicity. In conclusion, this improved system is based on magnetic targeting accelerated thrombolysis and is

  7. Inhibition of plasminogen activator inhibitor-1 activity results in promotion of endogenous thrombolysis and inhibition of thrombus extension in models of experimental thrombosis

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Biemond, B. J.; van Zonneveld, A. J.; ten Cate, J. W.; Pannekoek, H.

    1992-01-01

    We investigated the effect of inhibition of plasminogen activator inhibitor-1 (PAI-1) activity by a murine monoclonal anti-human PAI-1 antibody (MAI-12) on in vitro thrombolysis and on in vivo thrombolysis and thrombus extension in an experimental animal model for thrombosis. Thrombolysis, mediated

  8. Balloon catheter disruption of thrombus in conjunction with thrombolysis for the treatment of acute middle cerebral artery occlusion

    International Nuclear Information System (INIS)

    Liu Zhensheng; Wang Wei; Zhang Xinjiang; Fu Changbiao; Zhou Longjiang

    2009-01-01

    Objective: To assess the feasibility, safety, and efficacy of balloon disruption of thrombus by using a deflated balloon catheter combined with intra-arterial thrombolysis for the treatment of acute middle cerebral artery (MCA) occlusion. Methods: Five consecutive patients with acute MCA occlusion underwent balloon disruption combined with intra-arterial thrombolysis. The microballoon was inflated in the distal carotid artery and then deflated and advanced just distal to the occlusion site in the MCA. Thereafter, intra- arterial thrombolysis of the MCA was applied and the maximum dosage of urokinase was 500,000 U. Results: Complete recanalization was achieved in 3 patients and partial recanalization in 2. All patients got favourable clinical outcome. There was no major intracerebral hemorrhage. Conclusion: The penetration of the MCA with a deflated balloon catheter combined with an intra-arterial thrombolysis may be a safe and effective treatment for acute ischemic stroke. (authors)

  9. [Intravenous thrombolysis for acute ischemic stroke. A four years’ experience in a Chilean public hospital].

    Science.gov (United States)

    Soto V, Álvaro; Morales I, Gladys; Grandjean B, Marcela; Pollak W, Débora; Del Castillo C, Carolina; García F, Pía; Von Johnn A, Alexis; Riquelme G, Alfonso

    2017-04-01

    Intravenous thrombolysis (IVT) with alteplase (tissue plasminogen activator) is the standard pharmacological treatment in acute ischemic stroke (AIS), reducing disability in patients. To report the results a thrombolysis protocol during four years in a regional public hospital. Data from 106 consecutive patients aged 68 ± 13 years (57% men) who were treated with IVT, from May 2012 until April 2016, was analyzed. The median door-to-needle time was 80 minutes (interquartile range = 57-113). The median National Institute of Health Stroke Scale (NIHSS) scores on admission and at discharge were was 11.5 and 5 points respectively. At discharge, 27% of hospitalized patients had a favorable outcome (n = 99), defined as having 0 to 1 points in the modified Rankin scale. Symptomatic intracerebral hemorrhage and mortality rates were 5.7 and 13.1%, respectively. The thrombolysis rate rose from 0.7% in 2012 to 6% in 2016. The implementation of 24/7 neurology shifts in the Emergency Department allowed us to increase the amount and quality of IVT in our hospital, as measured by the rate of thrombolysis and by process indicators such as door-to-needle time.

  10. Segmentally enclosed thrombolysis in percutaneous transluminal angioplasty for femoropopliteal occlusions

    DEFF Research Database (Denmark)

    Jørgensen, B; Tønnesen, K H; Nielsen, J D

    1991-01-01

    Segmentally enclosed thrombolysis (SET) was performed immediately following 34 percutaneous transluminal angioplasties (PTAs) for femoropopliteal occlusions. The dilated segment was sealed off with a double balloon catheter, and recombinant tissue plasminogen activator (rt-PA) 1 mg/ml and heparin...

  11. Safety and functional outcome of thrombolysis in dissection-related ischemic stroke: a meta-analysis of individual patient data

    NARCIS (Netherlands)

    Zinkstok, Sanne M.; Vergouwen, Mervyn D. I.; Engelter, Stefan T.; Lyrer, Philippe A.; Bonati, Leo H.; Arnold, Marcel; Mattle, Heinrich P.; Fischer, Urs; Sarikaya, Hakan; Baumgartner, Ralf W.; Georgiadis, Dimitrios; Odier, Céline; Michel, Patrik; Putaala, Jukka; Griebe, Martin; Wahlgren, Nils; Ahmed, Niaz; van Geloven, Nan; de Haan, Rob J.; Nederkoorn, Paul J.

    2011-01-01

    The safety and efficacy of thrombolysis in cervical artery dissection (CAD) are controversial. The aim of this meta-analysis was to pool all individual patient data and provide a valid estimate of safety and outcome of thrombolysis in CAD. We performed a systematic literature search on intravenous

  12. Spraying effects on some physiological and behavioural traits of goats in a subtropical climate

    Directory of Open Access Journals (Sweden)

    Soner Cankaya

    2010-01-01

    Full Text Available Heat stress is one of the major factors adversely affecting animal welfare and thus economic benefits of farms. This study was designed to determine the effects of two different spraying methods on goats exposed to high air temperatures. Thirty goats were divided into three groups for the trial (sprayed once per day, OTS; sprayed twice per day, TTS; and non-sprayed, Controls. Respiration and pulse rates, rectal and surface temperatures (from head and udder skin were taken three times a day (08.00 - 09.00; 16.00 - 17.00 and 00.00 - 01.00 on hot summer days in July 2005 in a Mediterranean climate. Some behavioural aspects such as eating, ruminating, drinking, walking and resting, and daily feed and water consumption were regularly measured. Rectal temperatures, pulse and respiration rates, udder and head temperatures differed between the three groups. Rectal, head and udder temperatures and respiration and pulse rates increased at 16.00 relative to 08.00, and at 00.00 had returned to the same level as at 08.00. TTS goats showed smaller increases in all physiological measurements at 16.00 than the other groups. TTS goats spent more time than OTS and Control goats eating (P=0.002, ruminating (P=0.032 and walking (P=0.021, but less time drinking (P=0.041 and lying (P=0.001. TTS goats consumed more concentrate feed (P=0.001 and alfalfa hay (P=0.024 than the other two groups, whereas Control goats consumed more water (P=0.003 than the other groups. Ultimately, the spraying had positive effects on yearling goats for alleviating heat stress and improving animal welfare.

  13. Protective effects of angiopoietin-like 4 on the blood-brain barrier in acute ischemic stroke treated with thrombolysis in mice.

    Science.gov (United States)

    Zhang, Bin; Xu, Xiaofeng; Chu, Xiuli; Yu, Xiaoyang; Zhao, Yuwu

    2017-04-03

    Given the risk of blood-brain barrier damage (BBB) caused by ischemic and tissue plasminogen activator thrombolysis, the preservation of vascular integrity is important. Angiopoietin-like 4 (ANGPTL4), a protein secreted in hypoxia, is involved in the regulation of vascular permeability. We hypothesized that Angptl4 might exert a protective effect in thrombolysis through stabilizing blood-brain barrier and inhibit hyper-permeability. We investigated the role of Angptl4 in stroke using a transient focal cerebral ischemia mouse model. The treated mice were administered Angptl4 1h after the ischemic event upon reperfusion. Our results showed that Angptl4 combined with thrombolysis greatly reduced the infarct volume and consequent neurological deficit. Western blot analyses and gelatin zymography revealed that Angptl4 protected the integrity of the endothelium damaged by thrombolysis. Angptl4 inhibited the up-regulation of vascular endothelial growth factor (VEGF) in the vascular endothelium after stroke, which was suppressed by counteracting VEGFR signaling and diminishing downstream Src signaling, and led to the increased stability of junctions and improved endothelial cell barrier integrity. These findings demonstrated that Angptl4 protects the permeability of the BBB damaged by ischemic and thrombolysis. Suggested that Angptl4 might be a promising target molecule in therapies for vasoprotection after thrombolysis treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Functional outcome after primary endovascular therapy or IV thrombolysis alone for stroke. An observational, comparative effectiveness study.

    Science.gov (United States)

    Abilleira, Sònia; Ribera, Aida; Dávalos, Antonio; Ribó, Marc; Chamorro, Angel; Cardona, Pere; Molina, Carlos A; Martínez-Yélamos, Antonio; Urra, Xabier; Dorado, Laura; Roquer, Jaume; Martí-Fàbregas, Joan; Aja, Lucía; Tomasello, Alejandro; Castaño, Carlos; Blasco, Jordi; Cánovas, David; Castellanos, Mar; Krupinski, Jerzy; Guimaraens, Leopoldo; Perendreu, Joan; Ustrell, Xavier; Purroy, Francisco; Gómez-Choco, Manuel; Baiges, Joan Josep; Cocho, Dolores; Saura, Júlia; Gallofré, Miquel

    2014-01-01

    Among the acute ischemic stroke patients with large vessel occlusions and contraindications for the use of IV thrombolysis, mainly on oral anticoagulation or presenting too late, primary endovascular therapy is often performed as an alternative to the standard therapy even though evidence supporting the use of endovascular reperfusion therapies is not yet established. Using different statistical approaches, we compared the functional independence rates at 3 months among patients undergoing primary endovascular therapy and patients treated only with IV thrombolysis. We used data from a prospective, government-mandated and externally audited registry of reperfusion therapies for ischemic stroke (January 2011 to November 2012). Patients were selected if treated with either IV thrombolysis alone (n = 1,582) or primary endovascular thrombectomy (n = 250). A series of exclusions were made to homogenize the clinical characteristics among the two groups. We then carried out multivariate logistic regression and propensity score matching analyses on the final study sample (n = 1,179) to compare functional independence at 3 months, as measured by the modified Rankin scale scores 0-2, between the two groups. The unadjusted likelihood of good outcome was poorer among the endovascular group (OR: 0.69; 95% CI: 0.47-1.0). After adjustment, no differences by treatment modality were seen (OR: 1.51; 95% CI: 0.93-2.43 for primary endovascular therapy). Patients undergoing endovascular thrombectomy within 180-270 min (OR: 2.89; 95% CI: 1.17-7.15) and patients with severe strokes (OR: 1.84; 95% CI: 1.02-3.35) did better than their intravenous thrombolysis counterparts. The propensity score-matched analyses with and without adjustment by additional covariates showed that endovascular thrombectomy was as effective as intravenous thrombolysis alone in achieving functional independence (OR for unadjusted propensity score matched: 1.35; 95% CI: 0.9-2.02, OR for adjusted propensity score

  15. Nursing care of indwelling catheter thrombolysis for acute thrombosis in the arteriovenous fistula in hemodialysis patients

    International Nuclear Information System (INIS)

    Gao Peizhu; Ding Wenbin; Ming Zhibing; Sun Juyun

    2010-01-01

    Objective: To summarize the experience of the nursing care of indwelling catheter thrombolysis for acute thrombosis in the arteriovenous fistula in eight hemodialysis patients. Methods: After breaking thrombus through indwelling catheter, both bolus injection and micro-pump continuous infusion of urokinase was employed in eight hemodialysis patients with acute thrombosis in the arteriovenous fistula. The necessary nursing measures were carried out to assist the whole therapeutic procedure. Results: All the patients could well cooperate with the procedure of indwelling catheter thrombolysis and urokinase infusion. The reopening rate of the obstructed fistula was 100%. Conclusion: Indwelling catheter thrombolysis with urokinase infusion is a simple, effective and safe treatment for acute thrombosis in the arteriovenous fistula in hemodialysis patients. In order to obtain optimal results, necessary nursing measures must be carried out. (authors)

  16. Diagnosis and treatment of shock due to massive pulmonary embolism: approach with transesophageal echocardiography and intrapulmonary thrombolysis.

    Science.gov (United States)

    Krivec, B; Voga, G; Zuran, I; Skale, R; Pareznik, R; Podbregar, M; Noc, M

    1997-11-05

    To evaluate the diagnostic value of transesophageal echocardiography (TEE) as an initial diagnostic tool in shocked patients. The second objective was to study therapeutic impact of intrapulmonary thrombolysis in patients with diagnosed massive pulmonary embolism. Prospective observational study. Medical ICU in 800-bed general hospital. Twenty-four consecutive patients with unexplained shock and distended jugular veins. In 18 patients, right ventricular dilatation with global or segmental hypokinesis was documented. In addition, central pulmonary thromboemboli (12 patients), reduced contrast flow in right pulmonary artery (one patient), and right ventricular free wall akinesis (one patient) were found. No additional echocardiographic findings were apparent in four patients. According to pulmonary scintigraphy or autopsy, sensitivity of TEE for diagnosis of massive pulmonary embolism (MPE) in patients with right ventricular dilatation was 92% and specificity was 100%. In patients without right ventricular dilatation, left ventricular dysfunction (four patients) or cardiac tamponade (two patients) was confirmed. Intrapulmonary thrombolysis was evaluated in 11 of 13 patients with MPE. Two patients died prior to attempted thrombolysis. Three patients received streptokinase and eight received urokinase. Twenty-four hours after beginning of treatment, total pulmonary resistance index significantly decreased for 59% and mean pulmonary artery pressure for 31%. Cardiac index increased for 74%. Nine of 11 patients receiving thrombolysis survived to hospital discharge. Bedside TEE is a valuable tool for diagnosis of MPE. It enables immediate intrapulmonary thrombolysis, which seems to be an effective therapeutic alternative in our group of patients with obstructive shock.

  17. Long-Term Outcomes of Catheter-Directed Thrombolysis for Acute Lower Extremity Occlusions of Native Arteries and Prosthetic Bypass Grafts

    NARCIS (Netherlands)

    Schrijver, A. Marjolein; de Vries, Jean Paul P M; van den Heuvel, Daniel A F; Moll, Frans L.

    2016-01-01

    Background Catheter-directed thrombolysis is a well-accepted treatment for acute lower extremity occlusions of native arteries and bypass grafts. Several variables that affect outcomes of thrombolysis have been identified. The hypothesis of this study was that the long-term outcome after

  18. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-02-15

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  19. Effects of golden hour thrombolysis: a Prehospital Acute Neurological Treatment and Optimization of Medical Care in Stroke (PHANTOM-S) substudy.

    Science.gov (United States)

    Ebinger, Martin; Kunz, Alexander; Wendt, Matthias; Rozanski, Michal; Winter, Benjamin; Waldschmidt, Carolin; Weber, Joachim; Villringer, Kersten; Fiebach, Jochen B; Audebert, Heinrich J

    2015-01-01

    The effectiveness of intravenous thrombolysis in acute ischemic stroke is time dependent. The effects are likely to be highest if the time from symptom onset to treatment is within 60 minutes, termed the golden hour. To determine the achievable rate of golden hour thrombolysis in prehospital care and its effect on outcome. The prospective controlled Prehospital Acute Neurological Treatment and Optimization of Medical Care in Stroke study was conducted in Berlin, Germany, within an established infrastructure for stroke care. Weeks were randomized according to the availability of a specialized ambulance (stroke emergency mobile unit (STEMO) from May 1, 2011, through January 31, 2013. We included 6182 consecutive adult patients for whom a stroke dispatch (44.1% male; mean [SD] age, 73.9 [15.0] years) or regular care (45.0% male; mean [SD] age, 74.2 [14.9] years) were included. The STEMO was deployed when the dispatchers suspected an acute stroke during emergency calls. If STEMO was not available (during control weeks, when the unit was already in operation, or during maintenance), patients received conventional care. The STEMO is equipped with a computed tomographic scanner plus a point-of-care laboratory and telemedicine connection. The unit is staffed with a neurologist trained in emergency medicine, a paramedic, and a technician. Thrombolysis was started in STEMO if a stroke was confirmed and no contraindication was found. Rates of golden hour thrombolysis, 7- and 90-day mortality, secondary intracerebral hemorrhage, and discharge home. Thrombolysis rates in ischemic stroke were 200 of 614 patients (32.6%) when STEMO was deployed and 330 of 1497 patients (22.0%) when conventional care was administered (P golden hour thrombolysis was 6-fold higher after STEMO deployment (62 of 200 patients [31.0%] vs 16 of 330 [4.9%]; P golden hour thrombolysis had no higher risks for 7- or 90-day mortality (adjusted odds ratios, 0.38 [95% CI, 0.09-1.70]; P = .21 and 0.69 [95% CI

  20. Assessment of coagulation function and ultrasound features after reteplase and recombinant streptokinase thrombolysis of lower extremity deep venous thrombosis

    Directory of Open Access Journals (Sweden)

    Wei Xiong

    2016-07-01

    Full Text Available Objective: To assess coagulation function and ultrasound features after reteplase and recombinant streptokinase thrombolysis of lower extremity deep venous thrombosis. Methods: A total of 78 cases of patients with lower extremity deep venous thrombosis who were treated in our hospital were selected as research subjects and divided into observation group 39 cases and control group 39 cases according to different treatment regimens. Control group received recombinant streptokinase thrombolysis, observation group received reteplase thrombolysis, and then the effect of the two thrombolytic ways was evaluated by color Doppler ultrasonography and circulating blood test. Results: Ultrasound showed that complete recanalization rate of thrombus of observation group after treatment was higher than that of control group; plasma PT, APTT and TT values of observation group after thrombolysis were higher than those of control group, FIB, D-D, NO, ET, E-selectin, P-selectin, Hcy, CRP, IL-6, IL-8 and TNF-毩 values were lower than those of control group, and WBC, Nc and Mc cell number were less than those of control group. Conclusion: Reteplase for thrombolysis of lower extremity deep venous thrombosis has more distinguished effect on dissolving thrombus as well as optimizing body’s coagulation, inflammatory system state and other aspects, and is a more ideal thrombolytic drug.

  1. Cost-effectiveness of intravenous thrombolysis with alteplase within a 3-hour window after acute ischemic stroke

    DEFF Research Database (Denmark)

    Ehlers, Lars; Andersen, Grethe; Clausen, Lone Beltoft

    2006-01-01

    BACKGROUND AND PURPOSE: The aim of this study was to assess the costs and cost-effectiveness of intravenous thrombolysis treatment with alteplase (Actilyse) of acute ischemic stroke with 24-hour in-house neurology coverage and use of magnetic resonance imaging. METHODS: A health economic model...... was designed to calculate the marginal cost-effectiveness ratios for time spans of 1, 2, 3 and 30 years. Effect data were extracted from a meta-analysis of six large-scale randomized and placebo-controlled studies of thrombolytic therapy with alteplase. Cost data were extracted from thrombolysis treatment...... at Aarhus Hospital, Denmark, and from previously published literature. RESULTS: The calculated cost-effectiveness ratio after the first year was $55,591 US per quality-adjusted life-year (base case). After the second year, computation of the cost-effectiveness ratio showed that thrombolysis was cost...

  2. Pulsed voltage electrospray ion source and method for preventing analyte electrolysis

    Science.gov (United States)

    Kertesz, Vilmos [Knoxville, TN; Van Berkel, Gary [Clinton, TN

    2011-12-27

    An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

  3. Effect of panax notoginseng saponins on efficacy and hemorrhagic transformation of rt-PA intravenous thrombolysis in patients with acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Chun-sheng LI

    2016-11-01

    Full Text Available Objective To study the effect of panax notoginseng saponins (PNS on the efficacy and hemorrhagic transformation (HT of recombinant tissue-type plasminogen activator (rt-PA intravenous thrombolysis in patients with acute ischemic stroke.  Methods A total of 200 patients with early acute ischemic stroke (the length of time between attack and hospital admission < 4.50 h were divided into 2 groups according to random number table method: treatment group (N = 100 and control group (N = 100. The control group was treated with routine rt-PA intravenous thrombolysis treatment, and the treatment group was treated with rt-PA intravenous thrombolysis plus PNS injection. The ischemia-reperfusion injury index [malondialdehyde (MDA and superoxide dismutase (SOD], hemorrhagic transformation prediction index [matrix metalloproteinase-9 (MMP-9 and fibronectin (FN] and nerve function index [National Institutes of Health Stroke Scale (NIHSS and Barthel Index (BI] were measured and compared before treatment, 24 h after thrombolysis and 14 d after thrombolysis. Adverse drug reactions and hemorrhagic transformation rate were observed 14 d after thrombolysis, and the prognosis (mortality and BI was evaluated 12 months after thrombolysis.  Results Compared with control group, serum SOD (P = 0.000 and BI (P = 0.000 in treatment group were significantly higher, while serum MDA (P = 0.001, MMP-9 (P = 0.001, plasma FN (P = 0.000 and NIHSS score (P = 0.006 were significantly lower. In treatment group, 24 h after rt-PA intravenous thrombolysis plus PNS injection, serum MDA (P = 0.000, MMP-9 (P = 0.000 and BI (P = 0.000 were significantly increased, while NIHSS score (P = 0.000 was significantly decreased; 14 d after treatment, serum MDA (P = 0.000 and MMP-9 (P = 0.000 were decreased, serum SOD (P = 0.000 and BI (P = 0.000 were continuously increased, plasma FN (P = 0.000 and NIHSS score (P = 0.000 were continuously decreased. On the 14th day after thrombolysis

  4. THROMBOLYSIS OR PRIMARY PCI FOR MYOCARDIAL INFARCTION WITH ST-SEGMENT ELEVATION? THE STREAM TRIAL (STRATEGIC REPERFUSION EARLY AFTER MYOCARDIAL INFARCTION

    Directory of Open Access Journals (Sweden)

    V. A. Sulimov

    2013-01-01

    Full Text Available Ambiguous data about comparability regarding clinical outcomes for prehospital thrombolysis, coupled with timely coronary angiography, and primary percutaneous coronary intervention (PCI in the early after acute ST-segment elevation myocardial infarction (STEMI, there are now.In the STREAM trial 1892 patients with STEMI diagnosed within 3 hours after onset of symptoms, and whom it was impossible to perform primary PCI within 1 h after the first medical contact, were randomly assigned into two treatment groups: a primary PCI b prehospital thrombolytic therapy with bolus tenecteplase (dose decreased by half in patients aged ≥75 years in combination with clopidogrel and enoxaparin followed by admission to the hospital, where it was possible to perform PCI. Emergency coronary angiography performed if thrombolysis failed. Coronary angiography and PCI of the infarct-related artery were performed in the period from 6 to 24 hours after randomization and thrombolytic therapy in the case of an effective thrombolysis. Primary endpoints include a composite of death, shock, congestive heart failure, or reinfarction up to 30 days.The primary endpoint occurred in 116 of 939 patients (12.4 % of the thrombolysis group and in 135 of 943 patients (14.3% of the primary PCI group (relative risk in the group thrombolysis 0.86, 95% confidence interval 0.68-1.09, p=0.21. Emergency angiography was required in 36.3% of patients in the thrombolysis, and the remaining patients, coronary angiography and PCI were performed at a mean of 17 hours after randomization and thrombolytic therapy. Thrombolysis group had more intracranial hemorrhages than primary PCI group (1.0% vs 0.2%, p=0.04; after correction protocol and dose reduction by half of tenecteplase in patients ≥75 years: 0.5% vs. 0.3%, p=0.45. The rate of non- intracranial bleeding in two treatment groups did not differ.Prehospital thrombolysis followed by coronary angiography and timely PCI provide effective

  5. Mechanism of the potentiation of thrombolysis by pentoxifylline (Trental)

    International Nuclear Information System (INIS)

    Ambrus, J.L.; Ambrus, C.M.; Mahfzah, M.; Markus, J.A.; Klein, E.; Gastpar, H.

    1987-01-01

    Streptokinase induced thrombolysis of radioactive labeled human fibrin clots was potentiated by simultaneous treatment with pentoxifylline (Trental). This appears to be due in part to the prevention of platelet aggregation on the clot. In addition, release of t-PA and PgI2 from the endothelium and increases in red cell deformability may also play a role

  6. Mechanism of the potentiation of thrombolysis by pentoxifylline (Trental)

    Energy Technology Data Exchange (ETDEWEB)

    Ambrus, J.L.; Ambrus, C.M.; Mahfzah, M.; Markus, J.A.; Klein, E.; Gastpar, H.

    1987-01-01

    Streptokinase induced thrombolysis of radioactive labeled human fibrin clots was potentiated by simultaneous treatment with pentoxifylline (Trental). This appears to be due in part to the prevention of platelet aggregation on the clot. In addition, release of t-PA and PgI2 from the endothelium and increases in red cell deformability may also play a role.

  7. Selective Thrombolysis in Acute Deep Vein Thrombosis: Evaluation of Adjuvant Therapy In Vivo

    International Nuclear Information System (INIS)

    Roy, Sumit; Brosstad, Frank; Sakariassen, Kjell S.

    1999-01-01

    Purpose: To evaluate in a porcine model of acute deep vein thrombosis (DVT) the efficacy of dalteparin and antithrombin with respect to heparin for local adjuvant therapy during selective thrombolysis, and the utility of nitroglycerin and iloprost as heparin supplements. Methods: DVT was induced in both hind limbs using a previously described technique (n = 20). Thirty minutes later, the animal was heparinized (2500 IU IV), and bilateral sequestrated thrombolysis was performed using 8 mg alteplase: both external iliac veins were endoluminally occluded with Swan-Ganz catheters, and a multi-sideport infusion wire coaxially introduced through each catheter and advanced into the ipsilateral popliteal vein. In the control limbs, tissue plasminogen activator (tPA) 8 mg was injected as 0.8-ml boluses at 3-min intervals for 2 hr as a 0.25-mg/ml solution containing heparin 50 IU/ml (n 20). On the contralateral side, heparin was substituted with either dalteparin 50 IU/ml (n = 5) or antithrombin 12.5 IU/ml (n = 5), or supplemented with either nitroglycerin 0.075 mg/ml (n = 5) or iloprost (150 ng/ml) (n = 5). Blood samples were taken at predetermined intervals to measure the activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen concentration. At autopsy, the thrombus mass in the iliofemoral veins was measured, and the extent of residual thrombosis in the venous tributaries graded at four sites. Results: Bilateral thrombolysis was successfully completed in all animals. The median thrombus mass in the iliofemoral veins after thrombolysis was 0.48 g (range 0.06-1.58 g), 0.95 g (0.59-1.29 g), 0.74 g (0.52-0.96 g), and 0.29 g (0.0-0.77 g) for dalteparin, antithrombin, iloprost, and nitroglycerin respectively, as compared with 0.53 g (0.18-0.88 g) (p = 0.69), 0.97 g (0.46-1.15 g) (p = 0.69), 0.53 g (0.48-1.10 g) (p = 0.69), and 0.18 g (0.13-1.04 g) (p = 0.5) for the respective controls. Likewise, the severity of residual thrombosis in the venous

  8. Ultrafast high-repetition imaging of fuel sprays using picosecond fiber laser.

    Science.gov (United States)

    Purwar, Harsh; Wang, Hongjie; Tang, Mincheng; Idlahcen, Saïd; Rozé, Claude; Blaisot, Jean-Bernard; Godin, Thomas; Hideur, Ammar

    2015-12-28

    Modern diesel injectors operate at very high injection pressures of about 2000 bar resulting in injection velocities as high as 700 m/s near the nozzle outlet. In order to better predict the behavior of the atomization process at such high pressures, high-resolution spray images at high repetition rates must be recorded. However, due to extremely high velocity in the near-nozzle region, high-speed cameras fail to avoid blurring of the structures in the spray images due to their exposure time. Ultrafast imaging featuring ultra-short laser pulses to freeze the motion of the spray appears as an well suited solution to overcome this limitation. However, most commercial high-energy ultrafast sources are limited to a few kHz repetition rates. In the present work, we report the development of a custom-designed picosecond fiber laser generating ∼ 20 ps pulses with an average power of 2.5 W at a repetition rate of 8.2 MHz, suitable for high-speed imaging of high-pressure fuel jets. This fiber source has been proof tested by obtaining backlight images of diesel sprays issued from a single-orifice injector at an injection pressure of 300 bar. We observed a consequent improvement in terms of image resolution compared to standard white-light illumination. In addition, the compactness and stability against perturbations of our fiber laser system makes it particularly suitable for harsh experimental conditions.

  9. Stroke code improves intravenous thrombolysis administration in acute ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Chih-Hao Chen

    Full Text Available Timely intravenous (IV thrombolysis for acute ischemic stroke is associated with better clinical outcomes. Acute stroke care implemented with "Stroke Code" (SC may increase IV tissue plasminogen activator (tPA administration. The present study aimed to investigate the impact of SC on thrombolysis.The study period was divided into the "pre-SC era" (January 2006 to July 2010 and "SC era" (August 2010 to July 2013. Demographics, critical times (stroke symptom onset, presentation to the emergency department, neuroimaging, thrombolysis, stroke severity, and clinical outcomes were recorded and compared between the two eras.During the study period, 5957 patients with acute ischemic stroke were admitted; of these, 1301 (21.8% arrived at the emergency department within 3 h of stroke onset and 307 (5.2% received IV-tPA. The number and frequency of IV-tPA treatments for patients with an onset-to-door time of <3 h increased from the pre-SC era (n = 91, 13.9% to the SC era (n = 216, 33.3% (P<0.001. SC also improved the efficiency of IV-tPA administration; the median door-to-needle time decreased (88 to 51 min, P<0.001 and the percentage of door-to-needle times ≤60 min increased (14.3% to 71.3%, P<0.001. The SC era group tended to have more patients with good outcome (modified Rankin Scale ≤2 at discharge (49.5 vs. 39.6%, P = 0.11, with no difference in symptomatic hemorrhage events or in-hospital mortality.The SC protocol increases the percentage of acute ischemic stroke patients receiving IV-tPA and decreases door-to-needle time.

  10. Prediction of stroke thrombolysis outcome using CT brain machine learning

    Directory of Open Access Journals (Sweden)

    Paul Bentley

    2014-01-01

    Full Text Available A critical decision-step in the emergency treatment of ischemic stroke is whether or not to administer thrombolysis — a treatment that can result in good recovery, or deterioration due to symptomatic intracranial haemorrhage (SICH. Certain imaging features based upon early computerized tomography (CT, in combination with clinical variables, have been found to predict SICH, albeit with modest accuracy. In this proof-of-concept study, we determine whether machine learning of CT images can predict which patients receiving tPA will develop SICH as opposed to showing clinical improvement with no haemorrhage. Clinical records and CT brains of 116 acute ischemic stroke patients treated with intravenous thrombolysis were collected retrospectively (including 16 who developed SICH. The sample was split into training (n = 106 and test sets (n = 10, repeatedly for 1760 different combinations. CT brain images acted as inputs into a support vector machine (SVM, along with clinical severity. Performance of the SVM was compared with established prognostication tools (SEDAN and HAT scores; original, or after adaptation to our cohort. Predictive performance, assessed as area under receiver-operating-characteristic curve (AUC, of the SVM (0.744 compared favourably with that of prognostic scores (original and adapted versions: 0.626–0.720; p < 0.01. The SVM also identified 9 out of 16 SICHs, as opposed to 1–5 using prognostic scores, assuming a 10% SICH frequency (p < 0.001. In summary, machine learning methods applied to acute stroke CT images offer automation, and potentially improved performance, for prediction of SICH following thrombolysis. Larger-scale cohorts, and incorporation of advanced imaging, should be tested with such methods.

  11. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric

    2010-01-01

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  12. Cooling the vertical surface by conditionally single pulses

    Science.gov (United States)

    Karpov, Pavel; Nazarov, Alexander; Serov, Anatoly; Terekhov, Victor

    2017-10-01

    You Sprays with periodic supply of the droplet phase have great opportunities to control the heat exchange processes. Varying pulse duration and frequency of their repetition, we can achieve the optimal conditions of evaporative cooling with minimization of the liquid flow rate. The paper presents experimental data on studying local heat transfer on a large subcooled surface, obtained on the original setup with multinozzle controlled system of impact irrigation by the gas-droplet flow. A contribution to intensification of the spray parameters (flow rate, pulse duration, repetition frequency) per a growth of integral heat transfer was studied. Data on instantaneous distribution of the heat flux value helped us to describe the processes occurring on the studied surface. These data could describe the regime of "island" film cooling.

  13. Changing paradigms in thrombolysis in acute myocardial infarction.

    Science.gov (United States)

    Gotsman, M S; Rozenman, Y; Admon, D; Mosseri, M; Lotan, C; Zahger, D; Weiss, A T

    1997-05-23

    Acute myocardial infarction occurs when a ruptured coronary artery plaque causes sudden thrombotic occlusion of a coronary artery and cessation of coronary artery blood flow. This paper reviews the underlying coronary pathology in progressive coronary atherosclerosis, mechanisms of plaque rupture and arterial occlusion and the time relationship between coronary occlusion and myocardial necrosis. Reperfusion can be achieved by chemical thrombolysis with different thrombolytic agents. Early lysis is achieved best by prehospital administration, a transtelephonic monitor, a mobile intensive care unit, active general practitioner treatment or by warning the emergency room of impending arrival of a patient. Thrombolytic therapy may be unsuccessful and not achieve Grade III TIMI flow in less than 4 h (or even 2 h) due to inadequate or intermittent perfusion or reocclusion. Adjuvant therapy includes aspirin and platelet receptor antagonists. Bleeding is a constant danger. Direct percutaneous transluminal coronary angioplasty (PTCA) may be as effective or better than chemical thrombolysis. Reperfusion protects the myocardium and salvages viable tissue. It also improves mechanical remodelling of the ventricle. Long-term follow-up has shown that quantum leaps of fresh coronary occlusion causes step-wise progression in patient disability and that further early, prompt reperfusion can salvage myocardium and prevent this inexorable progress of the disease.

  14. [Bilateral deep venous thrombosis and vena cava aplasia treated with local thrombolysis

    DEFF Research Database (Denmark)

    Pelta, A.M.; Jørgensen, Maja; Just, Sven Richardt Lundgren

    2008-01-01

    In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete thr...... thrombus resolution and no valvular incompetence at three months follow-up. In our opinion this treatment should be offered even in complex cases of acute proximal deep venous thrombosis Udgivelsesdato: 2008/5/19......In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete...

  15. Direct venous thrombolysis and venous angioplasty in the upper extremity

    International Nuclear Information System (INIS)

    Hollmann, J.P.; Guenther, R.W.

    1987-01-01

    Venous thromboses of stenoses in the upper extremity are often the result of a compression syndrome of the shoulder girdle, the Paget-von Schroetter syndrome, vascular surgery, space-occupying lesions in the mediastinum or the result of catheterisation. Direct venous thrombolysis and venous angioplasty were performed successfully in six patients. (orig.) [de

  16. Elevated Factor VIII and von Willebrand Factor Levels Predict Unfavorable Outcome in Stroke Patients Treated with Intravenous Thrombolysis

    Directory of Open Access Journals (Sweden)

    Noémi Klára Tóth

    2018-01-01

    Full Text Available IntroductionPlasma factor VIII (FVIII and von Willebrand factor (VWF levels have been associated with the rate and severity of arterial thrombus formation and have been linked to outcomes following thrombolytic therapy in acute myocardial infarction patients. Here, we aimed to investigate FVIII and VWF levels during the course of thrombolysis in acute ischemic stroke (AIS patients and to find out whether they predict long-term outcomes.Materials and methodsStudy population included 131 consecutive AIS patients (median age: 69 years, 60.3% men who underwent i.v. thrombolysis with recombinant tissue plasminogen activator (rt-PA. Blood samples were taken on admission, 1 and 24 h after rt-PA administration to measure FVIII activity and VWF antigen levels. Neurological deficit of patients was determined according to the National Institutes of Health Stroke Scale (NIHSS. ASPECT scores were assessed using computer tomography images taken before and 24 h after thrombolysis. Intracranial hemorrhage was classified according to the European Cooperative Acute Stroke Study (ECASS II criteria. Long-term functional outcome was determined at 90 days after the event by the modified Rankin scale (mRS.ResultsVWF levels on admission were significantly elevated in case of more severe AIS [median and IQR values: NIHSS <6:189.6% (151.9–233.2%; NIHSS 6–16: 199.6% (176.4–250.8%; NIHSS >16: 247.8% (199.9–353.8%, p = 0.013]; similar, but non-significant trend was observed for FVIII levels. FVIII and VWF levels correlated well on admission (r = 0.748, p < 0.001 but no significant correlation was found immediately after thrombolysis (r = 0.093, p = 0.299, most probably due to plasmin-mediated FVIII degradation. VWF levels at all investigated occasions and FVIII activity before and 24 h after thrombolysis were associated with worse 24 h post-lysis ASPECT scores. In a binary backward logistic regression analysis including age, gender

  17. [Prehospital thrombolysis: A national perspective. Pharmaco-invasive strategy for early reperfusion of STEMI in Mexico].

    Science.gov (United States)

    Arriaga-Nava, Roberto; Valencia-Sánchez, Jesús-Salvador; Rosas-Peralta, Martin; Garrido-Garduño, Martin; Calderón-Abbo, Moisés

    2015-01-01

    To review the existing evidence on the role of prehospital thrombolysis in patients with ST-segment elevation acute myocardial infarction (STEMI) as part of a strategy of cutting edge to reduce the time of coronary reperfusion and as a consequence improves both the survival and function. We used the technique of exploration-reduction-evaluation-analysis and synthesis of related studies, with an overview of current recommendations, data from controlled clinical trials and from the national and international registries about the different strategies for STEMI reperfusion. In total, we examined 186 references on prehospital thrombolysis, 130 references in times door-treatment, 139 references in STEMI management and national and international registries as well as 135 references on rescue and primary percutaneous coronary intervention for STEMI. Finally the 48 references that were more relevant and informative were retained. The «time» factor is crucial in the success of early reperfusion in STEMI especially if thrombolysis is applied correctly during the prehospital time. The primary percutaneous coronary intervention is contingent upon its feasibility before 120 min from the onset of symptoms. In our midst to internationally, thrombolysis continues to be a strategy with great impact on their expectations of life and function of patients. Telecommunication systems should be incorporate in real time to the priority needs of catastrophic diseases such as STEMI where life is depending on time. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  18. Intra-arterial thrombolysis of digital artery occlusions in a patient with polycythemia vera.

    Science.gov (United States)

    Jud, Philipp; Hafner, Franz; Gary, Thomas; Ghanim, Leyla; Lipp, Rainer; Brodmann, Marianne

    2017-01-01

    There are limited therapeutic options for the resolution of digital artery occlusions. Intra-arterial thrombolysis with anticoagulative and thrombolytic drugs successfully restored the blood flow in the affected digital arteries.

  19. Cooling the vertical surface by conditionally single pulses

    Directory of Open Access Journals (Sweden)

    Karpov Pavel

    2017-01-01

    Full Text Available You Sprays with periodic supply of the droplet phase have great opportunities to control the heat exchange processes. Varying pulse duration and frequency of their repetition, we can achieve the optimal conditions of evaporative cooling with minimization of the liquid flow rate. The paper presents experimental data on studying local heat transfer on a large subcooled surface, obtained on the original setup with multinozzle controlled system of impact irrigation by the gas-droplet flow. A contribution to intensification of the spray parameters (flow rate, pulse duration, repetition frequency per a growth of integral heat transfer was studied. Data on instantaneous distribution of the heat flux value helped us to describe the processes occurring on the studied surface. These data could describe the regime of “island” film cooling.

  20. Local thrombolysis for patients of severe cerebral venous sinus thrombosis during puerperium

    International Nuclear Information System (INIS)

    Guo, Xin-bin; Fu, Zhenqiang; Song, Lai-jun; Guan, Sheng

    2013-01-01

    Objective: To explore and evaluate the efficacy of intrasinus thrombolysis (IST) in patients with cerebral venous sinus thrombosis (CVST) during postpartum period. Methods: 11 patients during postpartum period with CVST who received IST during July 2007–November 2011 were included. Urokinase was infused into the sinuses via a microcatheter. Magnetic resonance venography (MRV) was performed to assess the recanalization of venous sinuses. Results: Before discharge, the intracranial pressure in 11 patients was under 200 mmH 2 O. MRV confirmed that venous sinus of 9 patients were smooth. The cortex venous and deep venous recovered to normal. Venous sinus of 2 patients recanalized partly, and cortex venous and deep venous had compensation. 9 patients had good outcome and 2 patients had only mild deficits. Conclusion: Intrasinus thrombolysis is safe and effective in patients with severe cerebral venous sinus thrombosis during postpartum period

  1. R[iological interventions in central venous obstructions. Dilatation, stent-implantation and thrombolysis

    International Nuclear Information System (INIS)

    Mathias, K.; Jaeger, H.; Willaschek, J.; Theophil, B.

    1998-01-01

    Purpose: Venous congestion of the superior or inferior caval system has to be considered as a medical emergency. The results of various recanalization procedures and their utility are analyzed. Patients and methods: 176 patients with superior and 28 with inferior caval obstruction were treated with Gianturco-Z (n=39) and Wall Stents (n=207) respectively. Balloon venoplasty was performed prior to stent implanation. In 27 cases, local thrombolysis with urokinase was employed. Results: Interventional procedures were succesful in 198 and without success in 6 patients. In most patients, symptoms were relieved during or early after recanalization. No major complications were found. Discussion: Balloon angioplasty with stent placement and local thrombolysis are successful in the treatment of superior and inferior caval obstruction. Self-expanding Wallstents are superior to Gianturco-Z-stents. Oncologists should be m[e familiar with this type of treatment. (orig.) [de

  2. The role of interventional radiology in the management of deep venous thrombosis: advanced therapy.

    LENUS (Irish Health Repository)

    O'Sullivan, Gerard J

    2011-06-01

    Deep vein thrombosis (DVT) is often managed with a health care pathway that funnels patients to anticoagulation therapy alone. This "usual treatment" is designed to stop propagation and embolisation of venous thrombus but not remove it. Surgical thrombectomy was once the only option in severe cases in which limbs were threatened, but thrombus removal is no longer restricted to emergency cases. Interventional radiologists are now using advanced endovascular techniques to achieve thrombus removal in a minimally invasive manner in a very short treatment time, thereby quickly restoring patency, relieving acute symptoms, and potentially limiting the subsequent development of postthrombotic syndrome when followed with anticoagulation and compression regimens. This article provides an overview of the interventions available for treating DVT. One of the newer "single-session" techniques is isolated pharmacomechanical thrombolysis, which is described here in detail with supporting cases.

  3. The Role of Interventional Radiology in the Management of Deep Venous Thrombosis: Advanced Therapy

    International Nuclear Information System (INIS)

    O’Sullivan, Gerard J.

    2011-01-01

    Deep vein thrombosis (DVT) is often managed with a health care pathway that funnels patients to anticoagulation therapy alone. This “usual treatment” is designed to stop propagation and embolisation of venous thrombus but not remove it. Surgical thrombectomy was once the only option in severe cases in which limbs were threatened, but thrombus removal is no longer restricted to emergency cases. Interventional radiologists are now using advanced endovascular techniques to achieve thrombus removal in a minimally invasive manner in a very short treatment time, thereby quickly restoring patency, relieving acute symptoms, and potentially limiting the subsequent development of postthrombotic syndrome when followed with anticoagulation and compression regimens. This article provides an overview of the interventions available for treating DVT. One of the newer “single-session” techniques is isolated pharmacomechanical thrombolysis, which is described here in detail with supporting cases.

  4. Salvage intraosseous thrombolysis and extracorporeal membrane oxygenation for massive pulmonary embolism

    Directory of Open Access Journals (Sweden)

    Luke Cameron Northey

    2015-01-01

    Full Text Available Intraosseous access is an alternative route of pharmacotherapy during cardiopulmonary resuscitation. Extracorporeal membrane oxygenation (ECMO provides cardiac and respiratory support when conventional therapies fail. This case reports the use of intraosseous thrombolysis and ECMO in a patient with acute massive pulmonary embolism (PE. A 34-year-old female presented to the emergency department with sudden onset severe shortness of breath. Due to difficulty establishing intravenous access, an intraosseous needle was inserted into the left tibia. Echocardiography identified severe right ventricular dilatation with global systolic impairment and failure, indicative of PE. Due to the patient′s hemodynamic compromise a recombinant tissue plasminogen activator (Alteplase bolus was administered through the intraosseous route. After transfer to the intensive care unit, venous-arterial ECMO was initiated as further therapy. The patient recovered and was discharged 36 days after admission. This is the first report of combination intraosseous thrombolysis and ECMO as salvage therapy for massive PE.

  5. Corrosion properties of pulse-plated zinc-nickel alloy coatings

    Energy Technology Data Exchange (ETDEWEB)

    Alfantazi, A.M. [Univ. of British Columbia, Vancouver, British Columbia (Canada). Dept. of Metals and Materials Engineering; Erb, U. [Queen`s Univ., Kingston, Ontario (Canada)

    1996-11-01

    Corrosion properties of pulse-plated Zn-Ni alloy coating on a steel substrate were investigated using the neutral salt-spray test (ASTM B 117-81) and the potentiodynamic polarization technique (ASTM G 5-82). Performance of these alloy coatings with various Ni contents (up to 62 wt%) was compared to that of laboratory-prepared electrodeposited Zn coatings and commercial galvannealed (GA) steel. Results of the neutral salt-spray test indicated corrosion resistance of pulse-plated Zn-Ni alloy coatings was superior to that of the pure Zn and commercial GA coating. The Zn-20 wt% Ni and Zn-14 wt% Ni alloys gave the best protection of the Zn-Ni coatings tested. Potentiodynamic polarization tests confirmed excellent corrosion performance of the 20 wt% Ni alloy

  6. Study on fuel particle motion of a diesel spray; Diesel funmu ryushi no kyodo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, N. [Isuzu Motors Ltd., Tokyo (Japan); Tsujimura, K.

    1998-08-25

    This study was performed to clarify the mechanism of mixture formation at peripheral area of diesel spray with PIV technique. Two dimensional cross-sectional photographs of diesel spray were taken with double pulse laser sheet. Local fuel spray particles were analyzed with an auto-correlation method and velocity vector and vorticity of the fuel spray particle were obtained. The vortex number increased and vorticity scale became smaller and its value grew higher with both smaller injection nozzle diameter and higher fuel injection velocity. With this injection condition, the mixing of fuel spray with ambient gas seems to be improved and the turbulence is expected to increase in the regions of higher vortex number, higher vorticity and smaller vorticity scale. Based on above results, the branch-like structure of diesel fuel spray was considered to be caused by vortices which formed in the shear layer between the spray and the ambient gas. 14 refs., 18 figs., 1 tab.

  7. Preparatory catheter-directed thrombolysis together with assisted endovascular angioplasty for the treatment of chronic occlusive arterial disorders of lower extremities

    International Nuclear Information System (INIS)

    Zhang Fuxian; Zhang Changming; Hu Lu; Feng Yaping; Liang Gangzhu; Zhang Huan

    2010-01-01

    Objective: To evaluate the safety and efficacy of preparatory catheter-directed thrombolysis together with assisted endovascular angioplasty in treating chronic occlusive arterial disorders of lower extremities. Methods: From January 2008 to December 2009, preparatory catheter-directed thrombolysis together with assisted endovascular angioplasty was performed in 12 patients with chronic occlusive arterial disorders of lower extremities, including 8 males and 4 females with an average age of 56.3 years (within a range of 38-71 years). All 12 patients had a history of chronic ischemia of lower limb,the mean ill duration was 19.3 months (3-48 months). All patients complained of intermittent claudication with a mean distance of 125 m (50-200 m). Rest pain occurred in 5 patients (42%), toe necrosis was seen in 3 patients (25%) and critically ischemic limb in 4 patients (33%). Ankle-brachial index (ABI) was 0.00 0.65 with a mean of 0.33. In all 12 patients catheter-directed thrombolysis with rt-PA or urokinase was initially carried out, which was followed by endovascular angioplasty (balloon dilatation or stent placement) in two days. The clinical data and the therapeutic results were analyzed. Results: Technical success was achieved in all 12 patients. The mean time of thrombolysis was 48 hours. Of 12 patients, rt-PA was employed in 4 and urokinase in 8. The occluded length of the diseased arteries before the treatment was 60-150 mm, with a mean of 80 mm. After catheter-directed thrombolysis,the occluded length decreased to 10-50 mm (mean of 30 mm). Endovascular angioplasty was successfully completed in all patients after thrombolysis therapy. Postoperative ABI was 0.64-1.0 (mean of 0.86), which was increased by 0.53 when compared to the preoperative figure. During the perioperative period neither complications needed to be surgically treated nor death occurred. All patients were followed up, and the arteries remained open after one year in all cases. Conclusion

  8. Thrombolysis and clinical outcome in patients with stroke after implementation of the Tyrol Stroke Pathway: a retrospective observational study.

    Science.gov (United States)

    Willeit, Johann; Geley, Theresa; Schöch, Johannes; Rinner, Heinrich; Tür, Andreas; Kreuzer, Hans; Thiemann, Norbert; Knoflach, Michael; Toell, Thomas; Pechlaner, Raimund; Willeit, Karin; Klingler, Natalie; Praxmarer, Silvia; Baubin, Michael; Beck, Gertrud; Berek, Klaus; Dengg, Christian; Engelhardt, Klaus; Erlacher, Thomas; Fluckinger, Thomas; Grander, Wilhelm; Grossmann, Josef; Kathrein, Hermann; Kaiser, Norbert; Matosevic, Benjamin; Matzak, Heinrich; Mayr, Markus; Perfler, Robert; Poewe, Werner; Rauter, Alexandra; Schoenherr, Gudrun; Schoenherr, Hans-Robert; Schinnerl, Adolf; Spiss, Heinrich; Thurner, Theresa; Vergeiner, Gernot; Werner, Philipp; Wöll, Ewald; Willeit, Peter; Kiechl, Stefan

    2015-01-01

    Intravenous thrombolysis for ischaemic stroke remains underused worldwide. We aimed to assess whether our statewide comprehensive stroke management programme would improve thrombolysis use and clinical outcome in patients. In 2008-09, we designed the Tyrol Stroke Pathway, which provided information campaigns for the public and standardised the entire treatment pathway from stroke onset to outpatient rehabilitation. It was commenced in Tyrol, Austria, as a long-term routine-care programme and aimed to include all patients with stroke in the survey area. We focused on thrombolysis use and outcome in the first full 4 years of implementation (2010-13). We enrolled 4947 (99%) of 4992 patients with ischaemic stroke who were admitted to hospitals in Tyrol; 675 (14%) of the enrollees were treated with alteplase. Thrombolysis administration in Tyrol increased after programme implementation, from 160 of 1238 patients (12·9%, 95% CI 11·1-14·9) in 2010 to 213 of 1266 patients (16·8%, 14·8-19·0) in 2013 (ptrend 2010-13stroke programmes, thrombolysis administration remained stable or declined between 2010 and 2013 (mean reduction 14·4%, 95% CI 10·9-17·9). Although the 3-month mortality was not affected by our programme (137 [13%] of 1060 patients in 2010 vs 143 [13%] of 1069 patients in 2013), 3-month functional outcome significantly improved (modified Rankin Scale score 0-1 in 375 [40%] of 944 patients in 2010 vs 493 [53%] of 939 in 2013; score 0-2 in 531 [56%] patients in 2010 and 615 [65%] in 2013; ptrend 2010-13stroke management programme, thrombolysis administration increased and clinical outcome significantly improved, although mortality did not change. We hope that these results will guide health authorities and stroke physicians elsewhere when implementing similar programmes for patients with stroke. Reformpool of the Tyrolean Health Care Fund. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Thrombolysis in the age of Primary Percutaneous Coronary Intervention: Mini-Review and Meta-analysis of Early PCI.

    Science.gov (United States)

    Al Shammeri, O; Garcia, LA

    2013-01-01

    Primary Percutaneous Coronary Intervention (PCI) is the treatment of choice for ST-segment Elevation Myocardial Infarction (STEMI) if performed within 90 minutes from first medical contact. However, primary PCI is only available for less than 25% of patients with STEMI. Early PCI or Pharmaco-invasive strategy has evolved from facilitated PCI but with more delayed timing from thrombolysis to PCI. Assess the safety and effectiveness of Early PCI. We reviewed the data of the available therapy options for patients with STEMI. Then we performed a meta-analysis for all randomized controlled trials of early PCI versus standard therapy. Five studies fulfilled our inclusion criteria. Our meta-analysis showed improved cardiovascular events with early PCI compared to standard therapy (odd ratio of 0.54; 95% Confidence interval 0.47-0.7, pearly PCI 4 to 24 hours after successful thrombolysis. Early PCI should be done to all STEMI patients within 24 hours after successful thrombolysis.

  10. Thrombolysis in the age of Primary Percutaneous Coronary Intervention: Mini-Review and Meta-analysis of Early PCI

    Science.gov (United States)

    Al Shammeri, O; Garcia, LA

    2013-01-01

    Objective Primary Percutaneous Coronary Intervention (PCI) is the treatment of choice for ST-segment Elevation Myocardial Infarction (STEMI) if performed within 90 minutes from first medical contact. However, primary PCI is only available for less than 25% of patients with STEMI. Early PCI or Pharmaco-invasive strategy has evolved from facilitated PCI but with more delayed timing from thrombolysis to PCI. Aim Assess the safety and effectiveness of Early PCI. Patients and Method We reviewed the data of the available therapy options for patients with STEMI. Then we performed a meta-analysis for all randomized controlled trials of early PCI versus standard therapy Results Five studies fulfilled our inclusion criteria. Our meta-analysis showed improved cardiovascular events with early PCI compared to standard therapy (odd ratio of 0.54; 95% Confidence interval 0.47-0.7, pPCI 4 to 24 hours after successful thrombolysis Conclusion Early PCI should be done to all STEMI patients within 24 hours after successful thrombolysis. PMID:23559909

  11. Experimental Studies of Spray Deposition on a Flat Surface in a Vacuum Environment

    Science.gov (United States)

    Golliher, Eric L.; Yao, S. C.

    2015-01-01

    Cooling of spacecraft components in the space environment is an on-going research effort. The electronics used in modern spacecraft are always changing and the heat flux is increasing. New, one-of-a-kind missions require new approaches to thermal control. In this research, under vacuum conditions, a pulsed water spray impinged on a small disc, while a high speed data acquisition system recorded the temperature histories of this copper disc. The water droplets froze quickly and accumulated on the disc as the spray continued. After the spray stopped, the frozen water that remained on the disc then sublimated into the vacuum environment and cooled the disc. This paper examines two important aspects of this process: 1) the difference in spray start up and shutdown in a vacuum environment versus in a standard atmospheric pressure environment, and 2) the water utilization efficiency in a vacuum environment due to the effects of drop trajectories and drop bouncing on the surface. Both phenomena play a role during spray cooling in a vacuum. This knowledge should help spacecraft designers plan for spray cooling as an option to cool spacecraft electronics, human metabolic generated heat, and heat from other sources.

  12. Intra-arterial thrombolysis in acute embolic stroke

    International Nuclear Information System (INIS)

    Shi Mingchao; Fang Shaokuan; Li Dong; Zhu Hui; Pang Meng; Wu Jiang; Wang Shouchun

    2008-01-01

    Objective: To evaluate the efficacy and safety of intra-arterial thrombolysis in acute embolic stroke (AES). Methods: 21 patients with AES were undertaken urokinase or recombinated tissue plasminogen activator through percutaneous femoral intraarterial thrombolysis (IAT) as the treated group, and another 42 patients without thrombolytic treatment were assigned as the control group, which were matched to the baseline National Institutes of Health Stroke Scale (NIHSS) scores with selected gender and age. 24 h NIHSS scores, 90 d modified Rankin Scale (mRS) scores, incidences of hemorrhagic transformation (HT) and mortalities of the two groups were compared after the treatment. Results: (1) The results of cerebral angiography showed that the total re-perfusion rate was 61.90%. The middle cerebral artery (MCA), the internal carotid artery (ICA) and the basilar artery (BA) re-perfusion rates were 83.33%, 28.57% and 50.00%, respectively. (2) The NIHSS scores after 24 h were lower in the treated (IAT) group than those in the control group (12.05±5.61 vs, 14.83±4.05, P<0.05). A favorable outcome (mRS of 0-2) was more frequently observed in the 1AT group (66.67%) than that in the control group (35.71%, P<0.05). (3) There was no significant difference between the rates of HT (28.57% vs. 16.77%) and also the similar mortality rates (19.05% vs. 16.67%) not significant between the two groups. No patient died of HT in both two groups. Conclusion: IAT may be an effective treatment for AES with comparative safety. (authors)

  13. Local intra-arterial thrombolysis in the carotid territory: does recanalization depend on the thromboembolus type?

    International Nuclear Information System (INIS)

    Urbach, H.; Wilhelm, K.; Flacke, S.; Schild, H.H.; Hartmann, A.; Pohl, C.; Klockgether, T.; Omran, H.

    2002-01-01

    Little is known about whether recanalization of carotid territory occlusions by local intra-arterial thrombolysis (LIT) depends on the type of the occluding thromboembolus. We retrospectively analysed the records of 62 patients with thromboembolic occlusions of the intracranial internal carotid artery (ICA) bifurcation or the middle cerebral artery who were undergoing LIT with urokinase within 6 h of symptom onset. We determined the influence of thromboembolus type (according to the TOAST criteria), thromboembolus location, leptomeningeal collaterals, time interval from onset of symptoms to onset of thrombolysis, and patient's age on recanalization. The thromboembolus type was atherosclerotic in six patients, cardioembolic in 29, of other determined etiology in four, and of undetermined etiology in 23 patients. Thirty-three (53%) thromboembolic occlusions were recanalized. The thromboembolus location but not the TOAST stroke type nor other parameters affected recanalization. In the TOAST group of patients with cardioembolic occlusions recanalization occurred significantly less frequently when transoesophageal echocardiography showed cardiac thrombus. The present study underlines the thromboembolus location as being the most important parameter affecting recanalization. The fact that thromboembolic occlusions originating from cardiac thrombi had a lower likelihood of being resolved by thrombolysis indicates the thromboembolus type as another parameter affecting recanalization. (orig.)

  14. Local intra-arterial thrombolysis in the carotid territory: does recanalization depend on the thromboembolus type?

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H; Wilhelm, K; Flacke, S; Schild, H H [Department of Radiology/Neuroradiology, University of Bonn, Sigmund Freud Strasse 25, 53105 Bonn (Germany); Hartmann, A; Pohl, C; Klockgether, T [Department of Neurology, University of Bonn, Sigmund Freud Strasse 25, 53105 Bonn (Germany); Omran, H [Department of Cardiology, University of Bonn, Sigmund Freud Strasse 25, 53105 Bonn (Germany)

    2002-08-01

    Little is known about whether recanalization of carotid territory occlusions by local intra-arterial thrombolysis (LIT) depends on the type of the occluding thromboembolus. We retrospectively analysed the records of 62 patients with thromboembolic occlusions of the intracranial internal carotid artery (ICA) bifurcation or the middle cerebral artery who were undergoing LIT with urokinase within 6 h of symptom onset. We determined the influence of thromboembolus type (according to the TOAST criteria), thromboembolus location, leptomeningeal collaterals, time interval from onset of symptoms to onset of thrombolysis, and patient's age on recanalization. The thromboembolus type was atherosclerotic in six patients, cardioembolic in 29, of other determined etiology in four, and of undetermined etiology in 23 patients. Thirty-three (53%) thromboembolic occlusions were recanalized. The thromboembolus location but not the TOAST stroke type nor other parameters affected recanalization. In the TOAST group of patients with cardioembolic occlusions recanalization occurred significantly less frequently when transoesophageal echocardiography showed cardiac thrombus. The present study underlines the thromboembolus location as being the most important parameter affecting recanalization. The fact that thromboembolic occlusions originating from cardiac thrombi had a lower likelihood of being resolved by thrombolysis indicates the thromboembolus type as another parameter affecting recanalization. (orig.)

  15. Tc99m-HMPAO Neuro--SPECT Assessment of Ischemic Penumbra in Acute Brain Infarct: Control of Intra-arterial Thrombolysis Treatment

    International Nuclear Information System (INIS)

    Mena, Francisco; Mena, Ismael; Ducci, Hector; Soto, Francisco; Pedraza, Luis; Contreras, Andrea; Miranda, Marcelo; Basaez, Esteban; Fruns, Manuel

    2004-01-01

    Acute brain infarct is a medical emergency potentially reversible if treated with thrombolysis, an approved therapy, if performed in the first 3 to 6 hours of evolution. Thrombolysis has many benefits, but it also has associated risks, mainly development of intracranial hemorrhage. The selection of which patient should receive this type of treatment had been an important research topic over the last decade. As a consequence neuroimaging of brain infarct has significantly improved during the last few years. A variety of diagnostic studies are now available in the evaluation of brain infarct and in particular of potentially reversible brain ischemia, including magnetic resonance imaging (MRI) diffusion-perfusion, perfusion computed tomography (CT) and functional neuroimaging techniques includes positron emission tomography (PET) and single-photon emission tomography (SPECT). The aim of this study is to present our experience with a group of patients that presented with acute brain ischemia and had a NeuroSPECT evaluation before and after intra-arterial thrombolysis and/or possible stent placement, in the treatment of acute brain infarct. Methods: 16 patients were treated acutely for a significant ischemic stroke with the following protocol. 1) Admission, and complete neurological evaluation. 2) Brain CT scan performed to rule out hemorrhage or established infarct. 3) IV injection of 1100MBq Tc 99m HMPAO (Ceretec tm ) 4) Conventional cerebral angiography and intra-arterial thrombolysis with tPA and /or angioplasty/stent if necessary. 5) NeuroSPECT assessment of ischemic penumbra (Pre-therapy results). 6) 14 of 16 patients received a NeuroSPECT (Post-therapy results) control at 24 hours. NeuroSPECT image acquisition was performed immediately following arterial thrombolysis with a dual Head Camera, Siemens ECAM, SHR collimators and conventional protocol. Image processing was performed using the Neurogam, Segami Corp. Software as previously reported in Alasbimn Journal 2

  16. Effect of the borax mass and pre-spray medium temperature on droplet size and velocity vector distributions of intermittently sprayed starchy solutions.

    Science.gov (United States)

    Naz, Muhammad Yasin; Sulaiman, Shaharin Anwar; Ariwahjoedi, Bambang

    2015-02-07

    Spray coating technology has demonstrated great potential in the slow release fertilizers industry. The better understanding of the key spray parameters benefits both the environment and low cost coating processes. The use of starch based materials to coat the slow release fertilizers is a new development. However, the hydraulic spray jet breakup of the non-Newtonian starchy solutions is a complex phenomenon and very little known. The aim of this research was to study the axial and radial distributions of the Sauter Mean Diameter (SMD) and velocity vectors in pulsing spray patterns of native and modified tapioca starch solutions. To meet the objective, high speed imaging and Phase Doppler Anemometry (PDA) techniques were employed to characterize the four compositions of the starch-urea-borax complex namely S0, S1, S2 and S3. The unheated solutions exhibited very high viscosities ranging from 2035 to 3030 cP. No jet breakup was seen at any stage of the nozzle operation at an injection pressure of 1-5 bar. However, at 80 °C temperature and 5 bar pressure, the viscosity was reduced to 455 to 638 cP and dense spray patterns emerged from the nozzle obscuring the PDA signals. The axial size distribution revealed a significant decrease in SMD along the spray centreline. The smallest axial SMD (51 to 79 μm) was noticed in S0 spray followed by S1, S2 and S3. Unlikely, the radial SMD in S0 spray did not vary significantly at any stage of the spray injection. This trend was attributed to the continuous growth of the surface wave instabilities on the native starch sheet. However, SMD obtained with S1, S2 and S3 varied appreciably along the radial direction. The mean velocity vector profiles followed the non-Gaussian distribution. The constant vector distributions were seen in the near nozzle regions, where the spray was in the phase of development. In far regions, the velocity vectors were poly-dispersed and a series of ups and downs were seen in the respective radial

  17. Local thrombolysis for patients of severe cerebral venous sinus thrombosis during puerperium

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xin-bin, E-mail: gxb3906080@sina.com [Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Fu, Zhenqiang, E-mail: fuzhenqiang1005@163.com [Department of Neurology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Song, Lai-jun, E-mail: laijunsong@sina.com [Department of Neurosurgery, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China); Guan, Sheng, E-mail: gsradio@126.com [Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, 1 Jianshe Road, Zhengzhou, 450052 (China)

    2013-01-15

    Objective: To explore and evaluate the efficacy of intrasinus thrombolysis (IST) in patients with cerebral venous sinus thrombosis (CVST) during postpartum period. Methods: 11 patients during postpartum period with CVST who received IST during July 2007–November 2011 were included. Urokinase was infused into the sinuses via a microcatheter. Magnetic resonance venography (MRV) was performed to assess the recanalization of venous sinuses. Results: Before discharge, the intracranial pressure in 11 patients was under 200 mmH{sub 2}O. MRV confirmed that venous sinus of 9 patients were smooth. The cortex venous and deep venous recovered to normal. Venous sinus of 2 patients recanalized partly, and cortex venous and deep venous had compensation. 9 patients had good outcome and 2 patients had only mild deficits. Conclusion: Intrasinus thrombolysis is safe and effective in patients with severe cerebral venous sinus thrombosis during postpartum period.

  18. Effect of urokinase thrombolysis on the cardiac function, coagulation, and fibrinolytic system in patients with AMI

    Directory of Open Access Journals (Sweden)

    Zhi-Bin Kuang

    2017-06-01

    Full Text Available Objective: To observe the effect of urokinase thrombolysis on the cardiac function, coagulation, and fibrinolytic system in patients with acute myocardial infarction (AMI. Methods: A total of 39 patients with AMI who were admitted in our hospital from March, 2016 to November, 2016 were included in the study and served as the observation group. The peripheral venous blood before and after thrombolysis was collected. The plasma NTproBNP level, related coagulation factors, and fibrinolysis indicators were detected. The cardiac function before treatment was evaluated. A total of 30 healthy individuals who came for physical examinations were served as the control group for contrastive analysis. Results: The plasma NT-proBNP, Fg, and D-D levels before thrombolysis in the observation group were significantly higher than those in the control group, while PT, APTT, and TT in the observation group were significantly shortened. The plasma NT-proBNP and D-D levels 2-48 h after thrombolysis in the observation group were significantly elevated first and reduced later and reached the peak 4 h after treatment, while PT, APTT, and TT were significantly extended first and shortened later. The plasma Fg level was significantly reduced first and elevated later and reached the minimum 4 h after treatment. During the treatment process, in the observation group, 2 had mucocutaneous hemorrhage, 3 had nasal hemorrhage, and 1 had gingival bleeding, but no gastrointestinal bleeding or cerebral hemorrhage occurred. Conclusions: The thrombolytic therapy can effectively reduce the coagulation activity in patients with AMI, strengthen the fibrinolysis activity, and improve the cardiac function.

  19. SPRAY CASTING

    OpenAIRE

    SALAMCI, Elmas

    2010-01-01

    ABSTRACT This paper is designed to provide a basic review of spray casting. A brief overview of the historical development of spray  casting and the description of plant and equipment have been given. Following metallurgical characteristics of spray formed alloys, process parameters and solidification mechanism of spray deposition have been discussed in detail. Finally, microstructure and mechanical properties of the selected spray cast Al-Zn-Mg-Cu alloys have been presented and comp...

  20. Impact of collateral circulation status on favorable outcomes in thrombolysis treatment: A systematic review and meta-analysis.

    Science.gov (United States)

    Wufuer, Alimu; Wubuli, Atikaimu; Mijiti, Peierdun; Zhou, Jun; Tuerxun, Shabier; Cai, Jian; Ma, Jianhua; Zhang, Xiaoning

    2018-01-01

    Collateral circulation affects the prognosis of patients with acute ischemic stroke (AIS) treated by thrombolysis. The present study performed a systematic assessment of the impact of the collateral circulation status on the outcomes of patients receiving thrombolysis treatment. Relevant full-text articles from the Cochrane Library, Ovid, Medline, Embase and PubMed databases published from January 1, 2000 to November 1, 2016 were retrieved. The quality of the studies was assessed and data were extracted by 2 independent investigators. The random-effects model was used to estimate the impact of good vs. poor collateral circulation, as well as baseline characteristics, on the outcome within the series presented as risk ratios. Subgroup analyses explored the potential factors that may interfere with the effects of the collateral circulation status on the outcome. A total of 29 studies comprising 4,053 patients were included in the present meta-analysis. A good collateral circulation status was revealed to have a beneficial effect on favorable functional outcome (modified Rankin scale, 0-3 at 3-6 months; Pcollateral circulation. Good collateral circulation was also associated with a lower rate of symptomatic intracranial hemorrhage (Pcollateral circulation was demonstrated to have a favorable prognostic value regarding the outcome for patients with AIS receiving thrombolysis treatment. Assessment of collateral circulation and penumbra area during pre-treatment imaging within an appropriate time-window prior to thrombolytic therapy will therefore improve the identification of AIS patients who may benefit from thrombolysis treatment.

  1. Thrombolysis with alteplase 3 to 4.5 hours after acute ischemic stroke

    DEFF Research Database (Denmark)

    Hacke, Werner; Kaste, Markku; Bluhmki, Erich

    2008-01-01

    BACKGROUND: Intravenous thrombolysis with alteplase is the only approved treatment for acute ischemic stroke, but its efficacy and safety when administered more than 3 hours after the onset of symptoms have not been established. We tested the efficacy and safety of alteplase administered between ...

  2. Acute iliofemoral venous thrombosis in patients with atresia of the inferior vena cava can be treated successfully with catheter-directed thrombolysis

    DEFF Research Database (Denmark)

    Broholm, Rikke; Jørgensen, Maja; Just, Sven

    2011-01-01

    To assess the effectiveness and clinical outcomes of catheter-directed thrombolysis in patients with atresia of the inferior vena cava (IVC) and acute iliofemoral deep vein thrombosis (DVT).......To assess the effectiveness and clinical outcomes of catheter-directed thrombolysis in patients with atresia of the inferior vena cava (IVC) and acute iliofemoral deep vein thrombosis (DVT)....

  3. Comparison of desmopressin (DDAVP tablet and intranasal spray in the treatment of central diabetes insipidus

    Directory of Open Access Journals (Sweden)

    "Bagher Larijani

    2005-07-01

    Full Text Available Desmoperssin is the drug of choice for treatment of central diabetes insipidus and most commonly it is used as intranasal spray. In this study, efficacy and side effects of oral desmopressin was compared with the intranasal spray. This study was before -after clinical trial on 14 outpatients (9 F, 5 M, age 14 -50 Y with central diabetes insipidus who had been treated with intranasal spray of desmopressin previously. Weight, pulse rate and blood pressure (sitting -standing, biochemical profile, serum electrolytes, 24h urine volume, specific gravity of urine and LFT was measured before and after 1 month study. Starting dose for each patient was one oral tablet of DDAVP (0.1 mg per 8 hours. Paired Samples T-Test was used for data analysis. No clinically significant changes were found as regard to weight, pulse rate, blood pressure, blood chemistry, electrolyte and urinalysis. Single reported adverse effect was headache (43% in tablet group and dyspnea (7% in spray group. Both dosage forms were able to control diurnal polyuria and nocturnal polyuria. The antidiuretic dose - equivalence ratio for intranasal to oral desmopressin was 1: 18. Spray was superior in terms of rapid onset of action and duration of antidiuretic action in 100% and 78% of cases (not significant, respectively. Tablets were more available and much more easily consumed as reported by patients, in 86% (P=0.0006. Treatment with tablets offers a good alternative to the intranasal route, especially in patients with chronic rhinitis or common cold and similar conditions.

  4. Thrombolysis in patients with prior stroke within the last 3 months.

    Science.gov (United States)

    Heldner, M R; Mattle, H P; Jung, S; Fischer, U; Gralla, J; Zubler, C; El-Koussy, M; Schroth, G; Arnold, M; Mono, M-L

    2014-12-01

    Patients with prior stroke within 3 months have been mostly excluded from randomized thrombolysis trials mainly because of the fear of an increased rate of symptomatic intracerebral hemorrhage (sICH). The aim of this study was to compare baseline characteristics and clinical outcome of thrombolyzed patients who had a previous stroke within the last 3 months with those not fulfilling this criterion (comparison group). In all, 1217 patients were included in our analysis (42.2% women, mean age 68.8 ± 14.4 years). Patients with previous stroke within the last 3 months (17/1.4%) had more often a basilar artery occlusion (41.2% vs. 10.8%) and less frequently a modified Rankin scale (mRS) score 0-1 prior to index stroke (88.2% vs. 97.3%) and a higher mean time lapse from symptom onset to thrombolysis (321 min vs. 262 min) than those in the comparison group. Stroke severity was not different between the two groups. Rates of sICH were 11.8% vs. 6%. None of the sICHs and only one asymptomatic intracerebral hemorrhage occurred in the region of the former infarct. At 3 months, favorable outcome (mRS ≤ 2) in patients with previous stroke within 3 months was 29.4% (vs. 48.9%) and mortality 41.2% (vs. 22.7%). In patients with prior stroke within the last 3 months, none of the sICHs and only one asymptomatic intracerebral hemorrhage occurred in the region of the former infarct. The high mortality was influenced by four patients, who died until discharge due to acute major index stroke. It is reasonable to include these patients in randomized clinical trials and registries to assess further their thrombolysis benefit-risk ratio. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.

  5. Insulin resistance is associated with a poor response to intravenous thrombolysis in acute ischemic stroke.

    Science.gov (United States)

    Calleja, Ana I; García-Bermejo, Pablo; Cortijo, Elisa; Bustamante, Rosa; Rojo Martínez, Esther; González Sarmiento, Enrique; Fernández-Herranz, Rosa; Arenillas, Juan F

    2011-11-01

    Insulin resistance (IR) may not only increase stroke risk, but could also contribute to aggravate stroke prognosis. Mainly through a derangement in endogenous fibrinolysis, IR could affect the response to intravenous thrombolysis, currently the only therapy proved to be efficacious for acute ischemic stroke. We hypothesized that high IR is associated with more persistent arterial occlusions and poorer long-term outcome after stroke thrombolysis. We performed a prospective, observational, longitudinal study in consecutive acute ischemic stroke patients presenting with middle cerebral artery (MCA) occlusion who received intravenous thrombolysis. Patients with acute hyperglycemia (≥155 mg/dL) receiving insulin were excluded. IR was determined during admission by the homeostatic model assessment index (HOMA-IR). Poor long-term outcome, as defined by a day 90 modified Rankin scale score ≥ 3, was considered the primary outcome variable. Transcranial Duplex-assessed resistance to MCA recanalization and symptomatic hemorrhagic transformation were considered secondary end points. A total of 109 thrombolysed MCA ischemic stroke patients were included (43.1% women, mean age 71 years). The HOMA-IR was higher in the group of patients with poor outcome (P = 0.02). The probability of good outcome decreased gradually with increasing HOMA-IR tertiles (80.6%, 1st tertile; 71.4%, 2nd tertile; and 55.3%, upper tertile). A HOMA-IR in the upper tertile was independently associated with poor outcome when compared with the lower tertile (odds ratio [OR] 8.54 [95% CI 1.67-43.55]; P = 0.01) and was associated with more persistent MCA occlusions (OR 8.2 [1.23-54.44]; P = 0.029). High IR may be associated with more persistent arterial occlusions and worse long-term outcome after acute ischemic stroke thrombolysis.

  6. Catheter-directed thrombolysis and pharmacomechanical thrombectomy improve midterm outcome in acute iliofemoral deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Tzu-Ting Kuo

    2017-02-01

    Conclusion: CDT and PMT have similar venous outcomes in patients with acute iliofemoral DVT, although PTS is less severe following PMT than after CDT. We propose that early and thorough removal of thrombus, using either CDT or PMT, is beneficial to prevent PTS.

  7. Systemic Thrombolysis in Acute Ischemic Stroke after Dabigatran Etexilate Reversal with Idarucizumab—A Case Report

    DEFF Research Database (Denmark)

    Tireli, Derya; He, Jun; Nordling, Mette Maria

    2017-01-01

    Introduction Idarucizumab is a reversal agent for dabigatran etexilate. By reversing the anticoagulating effect of dabigatran etexilate with idarucizumab (Praxbind), patients presenting with an acute ischemic stroke can now be eligible for thrombolysis. Patient We describe our experience with ida......Introduction Idarucizumab is a reversal agent for dabigatran etexilate. By reversing the anticoagulating effect of dabigatran etexilate with idarucizumab (Praxbind), patients presenting with an acute ischemic stroke can now be eligible for thrombolysis. Patient We describe our experience...... of embolic stroke in patients with atrial fibrillation. Dabigatran etexilate is an oral thrombin inhibitor that can be reversed by idarucizumab. Idarucizumab, a monoclonal antibody fragment, directly binds dabigatran etexilate and neutralizes its activity. Conclusion Reversal of dabigatran etexilate using...

  8. Endovascular Treatment of Left Iliofemoral Deep Vein Thrombosis Using Urokinase Thrombolysis and Adjunctive Aspiration Thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Sang Hyun; Lee, Do Yun; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    To evaluate the efficacy of adjunctive aspiration thrombectomy for the treatment of iliofemoral deep vein thrombosis (DVT). 24 patients (9 males and 15 females; mean age, 53 years), treated by aspiration thrombectomy were enrolled in this study. The day after undergoing urokinase (UK) thrombolysis, any residual thrombus over a long segment was treated by aspiration thrombectomy using a 12 Fr long sheath. Residual short-segment (< 10 cm) iliac vein thrombus and/or stenosis were treated with a stent. The evaluation of venous patency was conducted by color Doppler ultrasonography, venography and/or computed tomography. The technical and clinical success rates were 100% and 92%, respectively. Twenty-three patients were treated by UK thrombolysis and iliac stent. The overall patency rate at 1, 2 and 3 years was 85%, 82% and 81%, respectively. Over the course of the follow-up period, occlusion was observed in 4 cases (1 acute and 3 chronic cases). Periprocedural complication occurred in 4 cases (17%) in the form of a minimal hematoma or pain on the puncture site as well as a case of pulmonary embolism at one month after treatment. The adjunctive aspiration thrombectomy with conventional thrombolysis and stent placement can be an effective and safe method in the treatment of left iliofemoral DVT

  9. Local intra-arterial thrombolysis in the carotid territory: does recanalization depend on the thromboembolus type?

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H.; Wilhelm, K.; Flacke, S.; Schild, H.H. [Department of Radiology/Neuroradiology, University of Bonn, Sigmund Freud Strasse 25, 53105 Bonn (Germany); Hartmann, A.; Pohl, C.; Klockgether, T. [Department of Neurology, University of Bonn, Sigmund Freud Strasse 25, 53105 Bonn (Germany); Omran, H. [Department of Cardiology, University of Bonn, Sigmund Freud Strasse 25, 53105 Bonn (Germany)

    2002-08-01

    Little is known about whether recanalization of carotid territory occlusions by local intra-arterial thrombolysis (LIT) depends on the type of the occluding thromboembolus. We retrospectively analysed the records of 62 patients with thromboembolic occlusions of the intracranial internal carotid artery (ICA) bifurcation or the middle cerebral artery who were undergoing LIT with urokinase within 6 h of symptom onset. We determined the influence of thromboembolus type (according to the TOAST criteria), thromboembolus location, leptomeningeal collaterals, time interval from onset of symptoms to onset of thrombolysis, and patient's age on recanalization. The thromboembolus type was atherosclerotic in six patients, cardioembolic in 29, of other determined etiology in four, and of undetermined etiology in 23 patients. Thirty-three (53%) thromboembolic occlusions were recanalized. The thromboembolus location but not the TOAST stroke type nor other parameters affected recanalization. In the TOAST group of patients with cardioembolic occlusions recanalization occurred significantly less frequently when transoesophageal echocardiography showed cardiac thrombus. The present study underlines the thromboembolus location as being the most important parameter affecting recanalization. The fact that thromboembolic occlusions originating from cardiac thrombi had a lower likelihood of being resolved by thrombolysis indicates the thromboembolus type as another parameter affecting recanalization. (orig.)

  10. Perfusion computed tomography-guided intravenous thrombolysis for acute ischemic stroke beyond 4.5 hours: a case-control study.

    Science.gov (United States)

    García-Bermejo, Pablo; Calleja, Ana I; Pérez-Fernández, Santiago; Cortijo, Elisa; del Monte, José M; García-Porrero, Miguel; Fe Muñoz, M; Fernández-Herranz, Rosario; Arenillas, Juan F

    2012-01-01

    Extending the therapeutic window of intravenous thrombolysis for acute ischemic stroke beyond the established 4.5-hour limit is of critical importance in order to increase the proportion of thrombolysed stroke patients. In this setting, the capacity of MRI to select acute stroke patients for reperfusion therapies in delayed time windows has been and is being tested in clinical trials. However, whether the more available and cost-effective perfusion computed tomography (PCT) may be useful to select candidates for delayed intravenous thrombolysis remains largely unexplored. We aimed to evaluate the safety and efficacy of PCT-guided intravenous thrombolysis beyond 4.5 h after stroke onset. We prospectively studied all consecutive acute ischemic stroke patients treated with intravenous tissue plasminogen activator (tPA) in our stroke unit between January 2008 and December 2010. Patients treated within 0- 4.5 h were treated according to non-contrast CT (NCCT) criteria. Beyond 4.5 h, patients received intravenous tPA according to PCT criteria, i.e. an infarct core on cerebral blood volume (CBV) maps not exceeding one third of the middle cerebral artery (MCA) territory and tissue at risk as defined by mean transit time-CBV mismatch greater than 20%. Predetermined primary endpoints were symptomatic hemorrhagic transformation and favorable long-term outcome, while early neurological improvement and MCA recanalization were considered secondary endpoints. Statistical analysis included bivariate comparisons between the two groups for each endpoint and logistic regression models when significance was found in bivariate analyses. This study was approved by our local ethics committee. A total of 245 patients received intravenous thrombolysis. After the groups were matched by baseline National Institutes of Health Stroke Scale score, 172 patients treated at 4.5 h were finally included. Early and late groups were comparable regarding baseline variables; only cardioembolic etiology

  11. Can catheter-directed thrombolysis be applied to acute lower extremity artery embolism after recent cerebral embolism from atrial fibrillation?

    International Nuclear Information System (INIS)

    Si, T.-G.; Guo, Z.; Hao, X.-S.

    2008-01-01

    Purpose: To assess the feasibility and efficacy of catheter-directed thrombolysis with recombinant tissue plasminogen activator (rt-PA) for acute limb embolism in patients with recent cerebral embolism due to atrial fibrillation. Materials and methods: Eight patients (six men, two women; mean age 63.5 years) with acute embolic occlusion of two left common iliac arteries, four femoral arteries (three left; one right), and two right popliteal arteries were treated. All patients had a history of recent cerebral embolism (mean 6 days, range 5-15 days) and all had a history of atrial fibrillation (duration 5-10 years). Catheter-directed thrombolysis started a few hours (mean 6.2 h; range 3-10 h) after the onset of arterial embolism. Two 5 mg boluses of rt-PA were injected into the proximal clot through a 5 F end-hole catheter and, subsequently, two additional boluses of 5 mg rt-PA were injected into the emboli. In patients with residual emboli, infusion with rt-PA (1 mg/h) was continued. Percutaneous transluminal angioplasty was performed in three patients, and a stent was deployed in one patient. Results: Technical success was achieved in all patients. Clinical success rate was 87.5% (7/8). The one clinical failure was secondary to chronic occlusion of outflow runoff vessels. The mean duration of continuous rt-PA infusion was 3.6 h, the mean total dose of rt-PA administered was 23.6 mg (range 20-28 mg). There was no significant change in stroke scale scores during thrombolysis and no intracerebral haemorrhage was found at computed tomography (CT) after thrombolysis. Minor complications included haematomata at puncture sites (6/8), bleeding around the vascular sheath (2/8), and haematuria (1/8). During the follow-up period of 3-6 months, one patient suffered from recurrent cerebral embolism and died. Conclusions: Catheter-directed thrombolysis with rt-PA is an option for acute lower extremity arterial embolism in patients with recent cerebral embolism and a history of

  12. Can catheter-directed thrombolysis be applied to acute lower extremity artery embolism after recent cerebral embolism from atrial fibrillation?

    Energy Technology Data Exchange (ETDEWEB)

    Si, T.-G. [Department of interventional treatment, Tianjin medical university cancer Hospital and Institution, Tianjin (China); Guo, Z. [Department of interventional treatment, Tianjin medical university cancer Hospital and Institution, Tianjin (China)], E-mail: dr.guozhi@yahoo.com.cn; Hao, X.-S. [Department of interventional treatment, Tianjin medical university cancer Hospital and Institution, Tianjin (China)

    2008-10-15

    Purpose: To assess the feasibility and efficacy of catheter-directed thrombolysis with recombinant tissue plasminogen activator (rt-PA) for acute limb embolism in patients with recent cerebral embolism due to atrial fibrillation. Materials and methods: Eight patients (six men, two women; mean age 63.5 years) with acute embolic occlusion of two left common iliac arteries, four femoral arteries (three left; one right), and two right popliteal arteries were treated. All patients had a history of recent cerebral embolism (mean 6 days, range 5-15 days) and all had a history of atrial fibrillation (duration 5-10 years). Catheter-directed thrombolysis started a few hours (mean 6.2 h; range 3-10 h) after the onset of arterial embolism. Two 5 mg boluses of rt-PA were injected into the proximal clot through a 5 F end-hole catheter and, subsequently, two additional boluses of 5 mg rt-PA were injected into the emboli. In patients with residual emboli, infusion with rt-PA (1 mg/h) was continued. Percutaneous transluminal angioplasty was performed in three patients, and a stent was deployed in one patient. Results: Technical success was achieved in all patients. Clinical success rate was 87.5% (7/8). The one clinical failure was secondary to chronic occlusion of outflow runoff vessels. The mean duration of continuous rt-PA infusion was 3.6 h, the mean total dose of rt-PA administered was 23.6 mg (range 20-28 mg). There was no significant change in stroke scale scores during thrombolysis and no intracerebral haemorrhage was found at computed tomography (CT) after thrombolysis. Minor complications included haematomata at puncture sites (6/8), bleeding around the vascular sheath (2/8), and haematuria (1/8). During the follow-up period of 3-6 months, one patient suffered from recurrent cerebral embolism and died. Conclusions: Catheter-directed thrombolysis with rt-PA is an option for acute lower extremity arterial embolism in patients with recent cerebral embolism and a history of

  13. [Bilateral deep venous thrombosis and vena cava aplasia treated with local thrombolysis

    DEFF Research Database (Denmark)

    Pelta, A.M.; Jørgensen, Maja; Just, Sven Richardt Lundgren

    2008-01-01

    In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete...

  14. Spontaneous Splenic Rupture Following Intravenous Thrombolysis with Alteplase Applied as Stroke Therapy – Case Report and Review of Literature

    Science.gov (United States)

    Aleksic-Shihabi, Anka; Jadrijevic, Eni; Milekic, Nina; Bulicic, Ana Repic; Titlic, Marina; Suljic, Enra

    2016-01-01

    Introduction: Stroke is a medical emergency in neurology, and is one of the leading causes of death nowadays. At a recent time, a therapeutic method used in adequate conditions is thrombolysis, a treatment of an emerging clot in the brain vascular system by alteplase. The application of alteplase also has a high risk of life threatening conditions. Case report: This is a brief report of a case with thrombolysis complication which manifested as a spleen rupture. PMID:26980937

  15. Combination therapy with normobaric oxygen (NBO plus thrombolysis in experimental ischemic stroke

    Directory of Open Access Journals (Sweden)

    Singhal Aneesh B

    2009-07-01

    Full Text Available Abstract Background The widespread use of tissue plasminogen activator (tPA, the only FDA-approved acute stroke treatment, remains limited by its narrow therapeutic time window and related risks of brain hemorrhage. Normobaric oxygen therapy (NBO may be a useful physiological strategy that slows down the process of cerebral infarction, thus potentially allowing for delayed or more effective thrombolysis. In this study we investigated the effects of NBO started simultaneously with intravenous tPA, in spontaneously hypertensive rats subjected to embolic middle cerebral artery (MCA stroke. After homologous clot injection, animals were randomized into different treatment groups: saline injected at 1 hour; tPA at 1 hour; saline at 1 hour plus NBO; tPA at 1 hour plus NBO. NBO was maintained for 3 hours. Infarct volume, brain swelling and hemorrhagic transformation were quantified at 24 hours. Outcome assessments were blinded to therapy. Results Upon clot injection, cerebral perfusion in the MCA territory dropped below 20% of pre-ischemic baselines. Both tPA-treated groups showed effective thrombolysis (perfusion restored to nearly 100% and smaller infarct volumes (379 ± 57 mm3 saline controls; 309 ± 58 mm3 NBO; 201 ± 78 mm3 tPA; 138 ± 30 mm3 tPA plus NBO, showing that tPA-induced reperfusion salvages ischemic tissue and that NBO does not significantly alter this neuroprotective effect. NBO had no significant effect on hemorrhagic conversion, brain swelling, or mortality. Conclusion NBO can be safely co-administered with tPA. The efficacy of tPA thrombolysis is not affected and there is no induction of brain hemorrhage or edema. These experimental results require clinical confirmation.

  16. Thrombolysis for treating deep venous thrombosis by high-dose urokinase: the usefulness of preventive placement of inferior vena cava filter

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; He Shicheng; Qiu Haibo; Fang Wen; Zhu Guangyu; Deng Gang

    2002-01-01

    Objective: To investigate the feasibility and efficacy of high-dose urokinase thrombolysis for treating lower limb deep venous thrombosis (DVT) after inferior vena cava (IVC) filter placement. Methods: Thirteen patients of venographically proved DVT underwent preventive IVC filter placement for thrombolysis by high-dose urokinase. Antegrade infusion of high-dose urokinase was performed via the dorsalis pedis vein of the involved lower limb. The total dose of urokinase was 9 000 000 ∼ 16 000 000 units, and the procedure of thrombolysis was performed in ICU ward where the patients were closely monitored clinically and laboratorially. Results: A total of 13 IVC filters were successfully deployed without disposition and migration. The therapeutic effects were divided into four scales as follows: complete disappearance of the venous thrombosis and clinically asymptomatic (n = 2); remarkable recovery characterized by markedly improved clinical symptoms and venographically proved patent lumen in which the diameter was larger than 70% (n = 9); effective treatment indicating improved symptoms to some degrees and venographically proved patent lumen in which the diameter was smaller than 70% ( n = 2); and ineffective treatment (n = 0). No pulmonary embolism and hemorrhage occurred during the procedure of thrombolysis. Conclusion: High-dose urokinase for treating DVT is safe and effective after preventive placement of IVC filter

  17. Clinical study on HAT and SEDAN score scales and related risk factors for predicting hemorrhagic transformation following thrombolysis in acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Heng WEI

    2015-03-01

    Full Text Available Objective To investigate the value of HAT and SEDAN score scales in predicting hemorrhagic transformation (HT following the recombinant tissue-type plasminogen activator (rt-PA intravenous thrombolysis in acute ischemic stroke patients and risk factors affecting HT.  Methods A total of 143 patients with acute ischemic stroke underwent rt-PA intravenous thrombolysis within 4.50 h of onset and their clinical data were collected. According to head CT after thrombolysis, patients were divided into HT group (18 cases and non-HT group (125 cases. Single factor analysis was used to assess differences in HAT and SEDAN score scales and related risk factors of ischemic stroke in 2 groups, and further Logistic regression analysis was used to investigate independent predictors of HT. Receiver operating characteristic (ROC curve was used to evaluate the sensitivity and specificity of HAT and SEDAN score scales in predicting HT.  Results Univariate Logistic regression analysis showed that history of atrial fibrillation (AF, admission systolic blood pressure (SBP, admission blood glucose level, early low density of head CT, thrombolytic time window, National Institute of Health Stroke Scale (NIHSS, HAT and SEDAN scores were all risk factors for HT after thrombolysis (P < 0.05, for all. Multivariate Logistic regression analysis showed that history of AF (OR = 1.677, 95% CI: 1.332-2.111; P = 0.000, admission SBP (OR = 1.102, 95% CI: 1.009-1.204; P = 0.031, admission blood glucose level (OR = 1.870, 95% CI: 1.119-3.125; P = 0.017, thrombolysis time window (OR = 1.030, 95%CI: 1.009-1.052; P = 0.005, NIHSS score (OR = 1.574, 95%CI: 1.186-2.090; P = 0.002, HAT score (OR = 2.515, 95%CI: 1.273-4.970;P = 0.008 and SEDAN score (OR = 2.413, 95%CI: 1.123-5.185; P = 0.024 were risk factors for HT after thrombolysis. ROC curve analysis showed that HAT score could predict HT with 94.40% sensitivity and 41.60% specificity, and area under curve (AUC was 0.70. SEDAN

  18. The role of additional computed tomography in the decision-making process on the secondary prevention in patients after systemic cerebral thrombolysis

    Directory of Open Access Journals (Sweden)

    Sobolewski P

    2015-12-01

    Full Text Available Piotr Sobolewski,1 Grzegorz Kozera,2 Wiktor Szczuchniak,1 Walenty M Nyka2 1Department of Neurology and Stroke, Unit of Holy Spirit Specialist Hospital in Sandomierz, Sandomierz, Poland; 2Department of Neurology, Medical University of Gdańsk, Gdańsk, Poland Introduction: Patients with ischemic stroke undergoing intravenous (iv-thrombolysis are routinely controlled with computed tomography on the second day to assess stroke evolution and hemorrhagic transformation (HT. However, the benefits of an additional computed tomography (aCT performed over the next days after iv-thrombolysis have not been determined.Methods: We retrospectively screened 287 Caucasian patients with ischemic stroke who were consecutively treated with iv-thrombolysis from 2008 to 2012. The results of computed tomography performed on the second (control computed tomography and seventh (aCT day after iv-thrombolysis were compared in 274 patients (95.5%; 13 subjects (4.5%, who died before the seventh day from admission were excluded from the analysis.Results: aCTs revealed a higher incidence of HT than control computed tomographies (14.2% vs 6.6%; P=0.003. Patients with HT in aCT showed higher median of National Institutes of Health Stroke Scale score on admission than those without HT (13.0 vs 10.0; P=0.01 and higher presence of ischemic changes >1/3 middle cerebral artery territory (66.7% vs 35.2%; P<0.01. Correlations between presence of HT in aCT and National Institutes of Health Stroke Scale score on admission (rpbi 0.15; P<0.01, and the ischemic changes >1/3 middle cerebral artery (phi=0.03 existed, and the presence of HT in aCT was associated with 3-month mortality (phi=0.03.Conclusion: aCT after iv-thrombolysis enables higher detection of HT, which is related to higher 3-month mortality. Thus, patients with severe middle cerebral artery infarction may benefit from aCT in the decision-making process on the secondary prophylaxis. Keywords: ischemic stroke, iv-thrombolysis

  19. Heat jettisoning from solar-thermal driven LiBr-H{sub 2}O absorber cooling units by pulsed spraying a dry cooler with water; Waermeabwurf aus einer solarthermisch getriebenen LiBr- H{sub 2}O Absorptionskaeltemaschine durch gepulstes Bespruehen eines Trockenkuehlers mit Wasser

    Energy Technology Data Exchange (ETDEWEB)

    Gantenbein, P.; Helfenberger, R.; Frank, E.

    2010-07-01

    This short, illustrated final report discusses the removal of heat from solar-thermal driven LiBr-H{sub 2}O absorber cooling units by pulsed spraying a dry cooler with water. The reduction of electricity consumption for room cooling using conventional chillers is examined. Heat dissipation using open cooling towers and the disadvantages encountered are compared with heat dissipation using a dry cooler with heat-exchanger and fans. Additional evaporation cooling achieved by spraying the heat exchanger with water is described and discussed. The results of measurements made at the Institute for Solar Technology in Rapperswil, Switzerland, are presented and discussed.

  20. High quality ceramic coatings sprayed by high efficiency hypersonic plasma spraying gun

    International Nuclear Information System (INIS)

    Zhu Sheng; Xu Binshi; Yao JiuKun

    2005-01-01

    This paper introduced the structure of the high efficiency hypersonic plasma spraying gun and the effects of hypersonic plasma jet on the sprayed particles. The optimised spraying process parameters for several ceramic powders such as Al 2 O 3 , Cr 2 O 3 , ZrO 2 , Cr 3 C 2 and Co-WC were listed. The properties and microstructure of the sprayed ceramic coatings were investigated. Nano Al 2 O 3 -TiO 2 ceramic coating sprayed by using the high efficiency hypersonic plasma spraying was also studied. Compared with the conventional air plasma spraying, high efficiency hypersonic plasma spraying improves greatly the ceramic coatings quality but at low cost. (orig.)

  1. Perfusion-CT guided intravenous thrombolysis in patients with unknown-onset stroke: a randomized, double-blind, placebo-controlled, pilot feasibility trial.

    Science.gov (United States)

    Michel, Patrik; Ntaios, George; Reichhart, Marc; Schindler, Christian; Bogousslavsky, Julien; Maeder, Philip; Meuli, Reto; Wintermark, Max

    2012-06-01

    Patients with unknown stroke onset are generally excluded from acute recanalisation treatments. We designed a pilot study to assess feasibility of a trial of perfusion computed tomography (PCT)-guided thrombolysis in patients with ischemic tissue at risk of infarction and unknown stroke onset. Patients with a supratentorial stroke of unknown onset in the middle cerebral artery territory and significant volume of at-risk tissue on PCT were randomized to intravenous thrombolysis with alteplase (0.9 mg/kg) or placebo. Feasibility endpoints were randomization and blinded treatment of patients within 2 h after hospital arrival, and the correct application (estimation) of the perfusion imaging criteria. At baseline, there was a trend towards older age [69.5 (57-78) vs. 49 (44-78) years] in the thrombolysis group (n = 6) compared to placebo (n = 6). Regarding feasibility, hospital arrival to treatment delay was above the allowed 2 h in three patients (25%). There were two protocol violations (17%) regarding PCT, both underestimating the predicted infarct in patients randomized in the placebo group. No symptomatic hemorrhage or death occurred during the first 7 days. Three of the four (75%) and one of the five (20%) patients were recanalized in the thrombolysis and placebo group respectively. The volume of non-infarcted at-risk tissue was 84 (44-206) cm(3) in the treatment arm and 29 (8-105) cm(3) in the placebo arm. This pilot study shows that a randomized PCT-guided thrombolysis trial in patients with stroke of unknown onset may be feasible if issues such as treatment delays and reliable identification of tissue at risk of infarction tissue are resolved. Safety and efficiency of such an approach need to be established.

  2. Perfusion-CT guided intravenous thrombolysis in patients with unknown-onset stroke: a randomized, double-blind, placebo-controlled, pilot feasibility trial

    International Nuclear Information System (INIS)

    Michel, Patrik; Ntaios, George; Reichhart, Marc; Schindler, Christian; Bogousslavsky, Julien; Maeder, Philip; Meuli, Reto; Wintermark, Max

    2012-01-01

    Patients with unknown stroke onset are generally excluded from acute recanalisation treatments. We designed a pilot study to assess feasibility of a trial of perfusion computed tomography (PCT)-guided thrombolysis in patients with ischemic tissue at risk of infarction and unknown stroke onset. Patients with a supratentorial stroke of unknown onset in the middle cerebral artery territory and significant volume of at-risk tissue on PCT were randomized to intravenous thrombolysis with alteplase (0.9 mg/kg) or placebo. Feasibility endpoints were randomization and blinded treatment of patients within 2 h after hospital arrival, and the correct application (estimation) of the perfusion imaging criteria. At baseline, there was a trend towards older age [69.5 (57-78) vs. 49 (44-78) years] in the thrombolysis group (n = 6) compared to placebo (n = 6). Regarding feasibility, hospital arrival to treatment delay was above the allowed 2 h in three patients (25%). There were two protocol violations (17%) regarding PCT, both underestimating the predicted infarct in patients randomized in the placebo group. No symptomatic hemorrhage or death occurred during the first 7 days. Three of the four (75%) and one of the five (20%) patients were recanalized in the thrombolysis and placebo group respectively. The volume of non-infarcted at-risk tissue was 84 (44-206) cm 3 in the treatment arm and 29 (8-105) cm 3 in the placebo arm. This pilot study shows that a randomized PCT-guided thrombolysis trial in patients with stroke of unknown onset may be feasible if issues such as treatment delays and reliable identification of tissue at risk of infarction tissue are resolved. Safety and efficiency of such an approach need to be established. (orig.)

  3. MRI based thrombolysis for FLAIR-negative stroke patients within 4.5-6h after symptom onset.

    Science.gov (United States)

    Wei, Xiao-Er; Zhou, Jia; Li, Wen-Bin; Zhao, Yu-Wu; Li, Ming-Hua; Li, Yue-Hua

    2017-01-15

    To investigate the feasibility of DWI-FLAIR mismatch in identifying patients who might benefit from thrombolytic therapy within 4.5-6h, we analyzed the data of 105 ischemic stroke patients with known time of symptom onset who underwent MRI within 6h of stroke and thrombolysis between December 2006 and December 2013. They were divided into three groups: symptom onset within 4.5h (n=66); 4.5-6h and FLAIR images negative (n=9); and 4.5-6h and FLAIR images positive (n=30). Outcome of thrombolysis was assessed for each group by recanalization rate, National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) scores. The results showed that mismatch between positive DWI and negative FLAIR images identified patients within 4.5h of symptom onset with sensitivity, specificity, positive predictive value and negative predictive value of 40.9%, 76.9%, and 75% and 43.5%. Recanalization rate, NIHSS score and mRS score were all better in both the 0-4.5h and 4.5-6h FLAIR-negative groups than in the 4.5-6h FLAIR-positive group (psymptom onset, patients with negative FLAIR images may benefit from thrombolysis therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Effect of spray angle and spray volume on deposition of a medium droplet spray with air support in ivy pot plants.

    Science.gov (United States)

    Foqué, Dieter; Pieters, Jan G; Nuyttens, David

    2014-03-01

    Spray boom systems, an alternative to the predominantly-used spray guns, have the potential to considerably improve crop protection management in glasshouses. Based on earlier experiments, the further optimization of the deposits of a medium spray quality extended range flat fan nozzle type using easy adjustable spray boom settings was examined. Using mineral chelate tracers and water sensitive papers, the spray results were monitored at three plant levels, on the upper side and the underside of the leaves, and on some off-target collectors. In addition, the deposition datasets of all tree experiments were compared. The data showed that the most efficient spray distribution with the medium spray quality flat fan nozzles was found with a 30° forward angled spray combined with air support and an application rate of 1000 L ha(-1) . This technique resulted in a more uniform deposition in the dense canopy and increased spray deposition on the lower side of the leaves compared with the a standard spray boom application. Applying 1000 L ha(-1) in two subsequent runs instead of one did not seem to show any added value. Spray deposition can be improved hugely simply by changing some spray boom settings like nozzle type, angling the spray, using air support and adjusting the spray volume to the crop. © 2013 Society of Chemical Industry.

  5. Successful catheter directed thrombolysis of IVC and renal vein occlusive thrombus.

    LENUS (Irish Health Repository)

    McCarthy, E

    2011-11-01

    Thrombus formation is a recognised complication of IVC filter placement, however IVC and bilateral renal vein occlusion secondary to thrombus is much less common. We present a case of infrahepatic caval and bilateral renal vein occlusion secondary to thrombosis of a suprarenal IVC filter. With progressive clinical deterioration and failure of conservative medical management the patient underwent successful mechanical disruption and catheter directed thrombolysis.

  6. Optical fuel spray measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hillamo, H.

    2011-07-01

    Diesel fuel sprays, including fuel/air mixing and the physics of two-phase jet formation, are discussed in the thesis. The fuel/air mixing strongly affects emissions formation in spray combustion processes where the local combustion conditions dictate the emission formation. This study comprises optical measurements both in pressurized spray test rigs and in a running engine.The studied fuel injection was arranged with a common rail injection system and the injectors were operated with a solenoid-based injection valve. Both marine and heavy-duty diesel engine injectors were used in the study. Optical fuel spray measurements were carried out with a laser-based double-framing camera system. This kind of equipments is usually used for flow field measurements with Particle Image Velocimetry technique (PIV) as well as for backlight imaging. Fundamental fuel spray properties and spray formation were studied in spray test rigs. These measurements involved studies of mixing, atomization, and the flow field. Test rig measurements were used to study the effect of individual injection parameters and component designs. Measurements of the fuel spray flow field, spray penetration, spray tip velocity, spray angle, spray structure, droplet accumulation, and droplet size estimates are shown. Measurement campaign in a running optically accessible large-bore medium-speed engine was also carried out. The results from engine tests were compared with equivalent test rig measurements, as well as computational results, to evaluate the level of understanding of sprays. It was shown that transient spray has an acceleration and a deceleration phase. Successive flow field measurements (PIV) in optically dense diesel spray resulted in local and average velocity data of diesel sprays. Processing fuel spray generates a flow field to surrounding gas and entrainment of surrounding gas into fuel jet was also seen at the sides of the spray. Laser sheet imaging revealed the inner structure of diesel

  7. Electrocardiogram interpretation in general practice: relevance to prehospital thrombolysis.

    Science.gov (United States)

    McCrea, W A; Saltissi, S

    1993-01-01

    OBJECTIVE--To assess, in the context of their possible role in prehospital thrombolysis, the ability of general practitioners to recognise acute transmural myocardial ischaemia/infarction on an electrocardiogram. DESIGN--150 doctors (every fifth name) were selected from the alphabetical list of 750 on Merseyside general practitioner register and without prior warning were asked to interpret a series of six 12 lead electrocardiograms. Three of these showed acute transmural ischaemia/infarction, one was normal, and two showed non-acute abnormalities. Details of doctors' ages, postgraduate training, and clinical practice were sought. SETTING--General practitioners' surgeries and postgraduate centres within the Merseyside area. PARTICIPANTS--106 general practitioners (mean age 45 years) agreed to participate. MAIN OUTCOME MEASURE--Accuracy of general practitioners' interpretations of the six electrocardiograms. RESULTS--82% of general practitioners correctly recognised a normal electrocardiogram. Recognition of acute abnormalities was less reliable. Between 33% and 61% correctly identified acute transmural ischaemia/infarction depending on the specific trace presented. Accurate localisation of the site of the infarct was achieved only by between 8% and 30% of participants, while between 22% and 25% correctly interpreted non-acute abnormalities. Neither routine use of electrocardiography nor postgraduate hospital experience in general medicine was associated with significantly greater expertise. CONCLUSION--The current level of proficiency of a sample of general practitioners in the Merseyside area in recognising acute transmural ischaemia/infarction on an electrocardiogram suggests that refresher training is needed if general practitioners are to give prehospital thrombolysis. Images PMID:8398491

  8. Spray characteristics and spray cooling heat transfer in the non-boiling regime

    International Nuclear Information System (INIS)

    Cheng, Wen-Long; Han, Feng-Yun; Liu, Qi-Nie; Fan, Han-Lin

    2011-01-01

    Spray cooling is an effective method for dissipating high heat fluxes in the field of electronics thermal control. In this study, experiments were performed with distilled water as a test liquid to study the spray cooling heat transfer in non-boiling regime. A Phase Doppler Anemometry (PDA) was used to study the spray characteristics. The effects of spray flow rate, spray height, and inlet temperature on spray cooling heat transfer were investigated. It was found that the parameters affect heat transfer of spray cooling in non-boiling regime by the spray characteristics and working fluid thermophysical properties. Then the corresponding droplet axial velocity and Sauter mean diameter (SMD) were successfully correlated with mean absolute error of 15%, which were based upon the orifice diameter, the Weber and Reynolds numbers of the orifice flow prior to liquid breakup, dimensionless spray height and spray cross-section radius. The heat transfer in non-boiling regime was correlated with a mean absolute error of 7%, which was mainly associated with the working fluid thermophysical properties, the Weber and Reynolds numbers hitting the heating surface, dimensionless heating surface temperature and diameter. -- Highlights: → The spray flow rate, spray height, and inlet temperature affect heat transfer of spray cooling in non-boiling regime by the spray characteristics and the working fluid thermophysical properties. → Then the corresponding droplet axial velocity and Sauer mean diameter (SMD) were successfully correlated with mean absolute error of 15%. → The heat transfer in non-boiling regime was correlated with a mean absolute error of 7%.

  9. Layered growth with bottom-spray granulation for spray deposition of drug.

    Science.gov (United States)

    Er, Dawn Z L; Liew, Celine V; Heng, Paul W S

    2009-07-30

    The gap in scientific knowledge on bottom-spray fluidized bed granulation has emphasized the need for more studies in this area. This paper comparatively studied the applicability of a modified bottom-spray process and the conventional top-spray process for the spray deposition of a micronized drug during granulation. The differences in circulation pattern, mode of growth and resultant granule properties between the two processes were highlighted. The more ordered and consistent circulation pattern of particles in a bottom-spray fluidized bed was observed to give rise to layered granule growth. This resulted in better drug content uniformity among the granule batches and within a granule batch. The processes' sensitivities to wetting and feed material characteristics were also compared and found to differ markedly. Less robustness to differing process conditions was observed for the top-spray process. The resultant bottom-spray granules formed were observed to be less porous, more spherical and had good flow properties. The bottom-spray technique can thus be potentially applied for the spray deposition of drug during granulation and was observed to be a good alternative to the conventional technique for preparing granules.

  10. Spray deposition and spray drift in orchard spraying by multiple row sprayers

    NARCIS (Netherlands)

    Wenneker, M.; Zande, van de J.C.; Michielsen, J.G.P.; Stallinga, H.; Velde, van P.

    2016-01-01

    The evaluation of the latest data on spray drift in orchard spraying in the Netherlands, and measurements of surface water quality parameters show that the current legislation and measures are insufficient to protect the surface water. To meet the national and European objectives regarding surface

  11. PTV analysis of the entrained air into the diesel spray at high-pressure injection

    Science.gov (United States)

    Toda, Naoki; Yamashita, Hayato; Mashida, Makoto

    2014-08-01

    In order to clarify the effect of high-pressure injection on soot reduction in terms of the air entrainment into spray, the air flow surrounding the spray and set-off length indicating the distance from the nozzle tip to the flame region in diffusion diesel combustion were investigated using 300MPa injection of a multi-hole injector. The measurement of the air entrainment flow was carried out at non-evaporating condition using consecutive PTV (particle tracking velocimetry) method with a high-speed camera and a high-frequency pulse YAG laser. The set-off length was measured at highpressure and high-temperature using the combustion bomb of constant volume and optical system of shadow graph method. And the amount of air entrainment into spray until reaching set-off length in diffusion combustion was studied as a factor of soot formation.

  12. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong [School of Medicine, Wonkwang University, Iksan (Korea, Republic of)

    2000-09-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  13. Deep venous thrombosis in the lower extremity: catheter-directed thrombolysis

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Kim, En A; Park, Ki Han; Yoon, Kwon Ha; So, Byung Jun; Juhng, Seon Kwan; Won, Jin Jong

    2000-01-01

    To evaluate the efficacy of catheter-directed thrombolysis in treating symptomatic deep venous thrombosis (DVT) in lower limbs. Twenty-six consecutive patients (16 male and 10 female; mean age, 55 years) with lower extremity DVT underwent thrombolytic therapy. The duration of symptoms was 1-90 (mean, 17) days: 20 days or less in 16 cases (acute DVT) and less than 20 days in ten (chronic DVT). Catheter-directed infusions of urokinase were administered via ipsilateral popliteal veins, and angioplasty or stent placement was performed after the thrombolytic procedure. Oral medication of warfarin continued for six months, and for the evaluation of venous patency, follow-up ultrasonography was performed. The total dose of infused urokinase was 1,750,000-10,000,000 (mean 4,84,000) IU, and the total procedural time was 25-115 (mean, 64) hours. Lysis was complete in 16 cases (62%, all acute DVT), partial in five (19%, chronic DVT), and failed in five (19%, chronic DVT). Eight patients with venous stenosis and two with occlusion were treated by means of angioplasty (n=3D4) or Wallstent placement (n=3D6). Minor bleeding occurred in six cases and major complications in two (one of pulmonary embolism, and one of multiorgan failure). Catheter-directed thrombolysis with urokinase is effective for the treatment of DVT in lower limbs. (author)

  14. Effect of spray application technique on spray deposition in greenhouse strawberries and tomatoes.

    Science.gov (United States)

    Braekman, Pascal; Foque, Dieter; Messens, Winy; Van Labeke, Marie-Christine; Pieters, Jan G; Nuyttens, David

    2010-02-01

    Increasingly, Flemish greenhouse growers are using spray booms instead of spray guns to apply plant protection products. Although the advantages of spray booms are well known, growers still have many questions concerning nozzle choice and settings. Spray deposition using a vertical spray boom in tomatoes and strawberries was compared with reference spray equipment. Five different settings of nozzle type, size and pressure were tested with the spray boom. In general, the standard vertical spray boom performed better than the reference spray equipment in strawberries (spray gun) and in tomatoes (air-assisted sprayer). Nozzle type and settings significantly affected spray deposition and crop penetration. Highest overall deposits in strawberries were achieved using air-inclusion or extended-range nozzles. In tomatoes, the extended-range nozzles and the twin air-inclusion nozzles performed best. Using smaller-size extended-range nozzles above the recommended pressure range resulted in lower deposits, especially inside the crop canopy. The use of a vertical spray boom is a promising technique for applying plant protection products in a safe and efficient way in tomatoes and strawberries, and nozzle choice and setting should be carefully considered.

  15. The metabolic syndrome is associated with a higher resistance to intravenous thrombolysis for acute ischemic stroke in women than in men.

    Science.gov (United States)

    Arenillas, Juan F; Sandoval, Patricio; Pérez de la Ossa, Natalia; Millán, Mónica; Guerrero, Cristina; Escudero, Domingo; Dorado, Laura; López-Cancio, Elena; Castillo, José; Dávalos, Antoni

    2009-02-01

    The metabolic syndrome (MetS) might confer a higher resistance to intravenous thrombolysis in acute middle cerebral artery (MCA) ischemic stroke. MetS increases the risk of stroke in women to a greater extent than in men. We aimed to investigate whether there might be sex differences in the impact of MetS on the response to intravenous thrombolysis for acute MCA ischemic stroke. We prospectively studied consecutive ischemic stroke patients, treated with intravenous tissue-type plasminogen activator according to SITS-MOST criteria, with an MCA occlusion on prebolus transcranial Doppler examination. Resistance to thrombolysis was defined as the absence of complete MCA recanalization 24 hours after tissue-type plasminogen activator infusion by transcranial Doppler criteria. MetS was diagnosed according to the criteria established by the American Heart Association/National Heart, Lung, and Blood Institute 2005 statement. A total of 125 patients (75 men, 50 women; mean age, 67.6+/-11 years) were included. MetS was diagnosed in 76 (61%) patients. Resistance to clot lysis at 24 hours was observed in 53 (42%) patients. Two multivariate-adjusted, logistic-regression models identified that MetS was associated with a higher resistance to tissue-type plasminogen activator, independently of other significant baseline variables (odds ratio=9.8; 95% CI, 3.5 to 27.8; P=0.0001) and of the individual components of the MetS. The MetS was associated with a significantly higher odds of resistance to thrombolysis in women (odds ratio=17.5; 95% CI, 1.9 to 163.1) than in men (odds ratio=5.1; 95% CI, 1.6 to 15.6; P for interaction=0.0004). The effect of MetS on the resistance to intravenous thrombolysis for acute MCA ischemic stroke appears to be more pronounced in women than in men.

  16. A Retrospective Comparison of Ultrasound-Assisted Catheter-Directed Thrombolysis and Catheter-Directed Thrombolysis Alone for Treatment of Proximal Deep Vein Thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Tichelaar, Vladimir Y. I. G., E-mail: ynse.i.tichelaar@uit.no; Brodin, Ellen E.; Vik, Anders; Isaksen, Trond [UiT – The Arctic University of Norway, K. G. Jebsen – Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine (Norway); Skjeldestad, Finn Egil [UiT – The Arctic University of Norway, Research Group Epidemiology of Chronic Diseases, Department of Community Medicine (Norway); Kumar, Satish; Trasti, Nora C.; Singh, Kulbir [University Hospital of North Norway, Department of Radiology (Norway); Hansen, John-Bjarne [UiT – The Arctic University of Norway, K. G. Jebsen – Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine (Norway)

    2016-08-15

    BackgroundRecent studies have suggested that catheter-directed thrombolysis (CDT) reduces development of post-thrombotic syndrome (PTS). Ultrasound-assisted CDT (USCDT) might enhance the efficiency of thrombolysis. We aimed to compare USCDT with CDT on efficacy, safety, development of PTS, and quality of life after long-term follow-up.MethodsWe describe a retrospective case series of 94 consecutive patients admitted with iliofemoral or more proximal deep vein thrombosis (DVT) to the University Hospital from 2002 to 2011, treated either with CDT or USCDT. Scheduled follow-up visits took place between April 2013 and January 2014. Venography measured the degree of residual luminal obstruction of the affected veins. Each patient completed the Short Form 36-item health survey assessment and the Venous Insufficiency Epidemiological and Economic Study-Quality of Life/Symptoms questionnaires. PTS was assessed using the Villalta scale.ResultsRisk factors of DVT were equally distributed between groups. In the USCDT group, we observed a significant decline in the duration of thrombolytic treatment (<48 h: 27 vs. 10 %), shortened hospital stay (median 6.0 days (IQR 5.0–9.0) vs. 8.0 (IQR 5.8–12.0)), and less implantation of (intravenous) stents (30 vs. 55 %). There was no difference in patency (76 vs. 79 % fully patent), prevalence of PTS (52 vs. 55 %), or quality of life between groups after long-term follow-up (median 65 months, range: 15–141).ConclusionsIn this observational study, USCDT was associated with shortened treatment duration, shorter hospital stay, and less intravenous stenting, compared to CDT alone without affecting the long-term prevalence of PTS or quality of life.

  17. A Retrospective Comparison of Ultrasound-Assisted Catheter-Directed Thrombolysis and Catheter-Directed Thrombolysis Alone for Treatment of Proximal Deep Vein Thrombosis

    International Nuclear Information System (INIS)

    Tichelaar, Vladimir Y. I. G.; Brodin, Ellen E.; Vik, Anders; Isaksen, Trond; Skjeldestad, Finn Egil; Kumar, Satish; Trasti, Nora C.; Singh, Kulbir; Hansen, John-Bjarne

    2016-01-01

    BackgroundRecent studies have suggested that catheter-directed thrombolysis (CDT) reduces development of post-thrombotic syndrome (PTS). Ultrasound-assisted CDT (USCDT) might enhance the efficiency of thrombolysis. We aimed to compare USCDT with CDT on efficacy, safety, development of PTS, and quality of life after long-term follow-up.MethodsWe describe a retrospective case series of 94 consecutive patients admitted with iliofemoral or more proximal deep vein thrombosis (DVT) to the University Hospital from 2002 to 2011, treated either with CDT or USCDT. Scheduled follow-up visits took place between April 2013 and January 2014. Venography measured the degree of residual luminal obstruction of the affected veins. Each patient completed the Short Form 36-item health survey assessment and the Venous Insufficiency Epidemiological and Economic Study-Quality of Life/Symptoms questionnaires. PTS was assessed using the Villalta scale.ResultsRisk factors of DVT were equally distributed between groups. In the USCDT group, we observed a significant decline in the duration of thrombolytic treatment (<48 h: 27 vs. 10 %), shortened hospital stay (median 6.0 days (IQR 5.0–9.0) vs. 8.0 (IQR 5.8–12.0)), and less implantation of (intravenous) stents (30 vs. 55 %). There was no difference in patency (76 vs. 79 % fully patent), prevalence of PTS (52 vs. 55 %), or quality of life between groups after long-term follow-up (median 65 months, range: 15–141).ConclusionsIn this observational study, USCDT was associated with shortened treatment duration, shorter hospital stay, and less intravenous stenting, compared to CDT alone without affecting the long-term prevalence of PTS or quality of life.

  18. External validation of the ability of the DRAGON score to predict outcome after thrombolysis treatment

    DEFF Research Database (Denmark)

    Ovesen, Christian Aavang; Christensen, Anders; Nielsen, J K

    2013-01-01

    Easy-to-perform and valid assessment scales for the effect of thrombolysis are essential in hyperacute stroke settings. Because of this we performed an external validation of the DRAGON scale proposed by Strbian et al. in a Danish cohort. All patients treated with intravenous recombinant plasmino......Easy-to-perform and valid assessment scales for the effect of thrombolysis are essential in hyperacute stroke settings. Because of this we performed an external validation of the DRAGON scale proposed by Strbian et al. in a Danish cohort. All patients treated with intravenous recombinant...... and their modified Rankin Scale (mRS) was assessed after 3 months. Three hundred and three patients were included in the analysis. The DRAGON scale proved to have a good discriminative ability for predicting highly unfavourable outcome (mRS 5-6) (area under the curve-receiver operating characteristic [AUC-ROC]: 0...

  19. Indoor spray measurement of spray drift potential using a spray drift test bench : effect of drift-reducing nozzle types, spray boom height, nozzle spacing and forward speed

    NARCIS (Netherlands)

    Moreno Ruiz, J.R.

    2014-01-01

    In a series of indoor experiments spray drift potential was assessed when spraying over a spray drift testbench with two different driving speeds, 2m/s and 4m/s, two different spray boom heights, 30 cm and 50 cm, and two different nozzle spacing, 25 cm and 50 cm, for six different nozzle types. The

  20. Studies on Microscopic Structure of Diesel Sprays under Atmospheric and High Gas Pressures

    Directory of Open Access Journals (Sweden)

    D. Deshmukh

    2014-06-01

    Full Text Available In the present work, the spray structure of diesel from a 200-μm, single-hole solenoid injector is studied using microscopic imaging at injection pressures of 700, 1000 and 1400 bar for various gas pressures. A long-distance microscope with a high resolution camera is used for spray visualization with a direct imaging technique. This study shows that even at very high injection pressures, the spray structure in an ambient environment of atmospheric pressure reveals presence of entangled ligaments and non-spherical droplets during the injection period. With increase in the injection pressure, the ligaments tend to get smaller and spread radially. The spray structure studies are also conducted at high gas pressures in a specially designed high pressure chamber with optical access. The near nozzle spray structure at the end of the injection shows that the liquid jet breakup is improved with increase in gas density. The droplet size measurement is possible only late in the injection duration when the breakup appears to be complete and mostly spherical droplets are observed. Hence, droplet size measurements are performed after 1.3 ms from start of the injection pulse. Spatial and temporal variation in Sauter Mean Diameter (SMD is observed and reported for the case corresponding to an injection pressure of 700 bar. Overall, this study has highlighted the importance of verifying the extentof atomization and droplet shape even in dense sprays before using conventional dropsizing methods such as PDPA.

  1. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, P., E-mail: mportcal@upo.es [Department of Physical, Chemical and Natural Systems, Universidad Pablo de Olavide, 41013 Seville (Spain); Antúnez, V.; Ortiz, R.; Martín, J.M. [Department of Physical, Chemical and Natural Systems, Universidad Pablo de Olavide, 41013 Seville (Spain); Gómez, M.A. [Instituto Andaluz de Patrimonio Histórico, Camino de los Descubrimientos s/n, 41092 Seville (Spain); Hortal, A.R.; Martínez-Haya, B. [Department of Physical, Chemical and Natural Systems, Universidad Pablo de Olavide, 41013 Seville (Spain)

    2013-10-15

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  2. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    International Nuclear Information System (INIS)

    Ortiz, P.; Antúnez, V.; Ortiz, R.; Martín, J.M.; Gómez, M.A.; Hortal, A.R.; Martínez-Haya, B.

    2013-01-01

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  3. Comparative study of pulsed laser cleaning applied to weathered marble surfaces

    Science.gov (United States)

    Ortiz, P.; Antúnez, V.; Ortiz, R.; Martín, J. M.; Gómez, M. A.; Hortal, A. R.; Martínez-Haya, B.

    2013-10-01

    The removal of unwanted matter from surface stones is a demanding task in the conservation of cultural heritage. This paper investigates the effectiveness of near-infrared (IR) and ultraviolet (UV) laser pulses for the cleaning of surface deposits, iron oxide stains and different types of graffiti (black, red and green sprays and markers, and black cutting-edge ink) on dolomitic white marble. The performance of the laser techniques is compared to common cleaning methods on the same samples, namely pressurized water and chemical treatments. The degree of cleaning achieved with each technique is assessed by means of colorimetric measurements and X-ray microfluorescence. Eventual morphological changes induced on the marble substrate are monitored with optical and electronic microscopy. It is found that UV pulsed laser ablation at 266 nm manages to clean all the stains except the cutting-edge ink, although some degree of surface erosion is produced. The IR laser pulses at 1064 nm can remove surface deposits and black spray acceptably, but a yellowing is observed on the stone surface after treatment. An economic evaluation shows that pulsed laser cleaning techniques are advantageous for the rapid cleaning of small or inaccessible surface areas, although their extensive application becomes expensive due to the long operating times required.

  4. Transjugular Intrahepatic Portosystemic Shunt, Mechanical Aspiration Thrombectomy, and Direct Thrombolysis in the Treatment of Acute Portal and Superior Mesenteric Vein Thrombosis

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Bovio, Giulio; Dahamane, M'Hamed; Centanaro, Monica

    2007-01-01

    A patient was admitted because of severe abdominal pain, anorexia, and intestinal bleeding. Contrast-enhanced multidetector computed tomography demonstrated acute portal and superior mesenteric vein thrombosis (PSMVT). The patient was treated percutaneously with transjugular intrahepatic portosystemic shunt (TIPS), mechanical aspiration thrombectomy, and direct thrombolysis, and 1 week after the procedure, complete patency of the portal and superior mesenteric veins was demonstrated. TIPS, mechanical aspiration thrombectomy, and direct thrombolysis together are promising endovascular techniques for the treatment of symptomatic acute PSMVT

  5. Catheter-Directed Thrombolysis for Treatment of Deep Venous Thrombosis in the Upper Extremities

    International Nuclear Information System (INIS)

    Vik, Anders; Holme, Pal Andre; Singh, Kulbir; Dorenberg, Eric; Nordhus, Kare Christian; Kumar, Satish; Hansen, John-Bjarne

    2009-01-01

    Traditional anticoagulant treatment of deep venous thrombosis (DVT) in the upper extremities (UEDVT) is associated with a relatively high incidence of postthrombotic syndrome (PTS). Catheter-directed thrombolysis (CDT) for UEDVT would provide efficient thrombolysis with less subsequent PTS than during traditional anticoagulation. Primary efficacy, complications, and long-term results after CDT are reported in a retrospective cohort (2002-2007) of patients (n = 30) with DVT in the upper extremities. PTS was assessed by a modified Villalta scale. UEDVT was unprovoked in 11 (37%) cases and effort related in 9 (30%) cases. The median duration of symptoms prior to CDT was 7.0 days (range, 1-30); median duration of thrombolysis treatment, 70 h (range, 24-264 h); and the median amount of rt-PA infused during CDT, 52 mg (range, 19-225 mg). Major bleeding was registered in three (9%) patients, and CDT was stopped prematurely in three patients due to local hematoma. No intracerebral bleeding, clinical pulmonary embolism, or deaths occurred during treatment. Grade II (>50%) or III (>90%) lysis was present in 29 patients (97%) at the end of CDT. Bleeding complications increased by each day of delay from the debut of symptoms to the start of treatment (OR, 1.20; 95% CI, 1.01-1.42). At follow-up (n = 29; median, 21 months; range, 5-58 months), 11 (38%) patients had occluded veins, whereas 18 (62%) had patent veins. However, stenosis of varying severity was present in eight of those with a patent vein. No patients had severe PTS, whereas six (21%) experienced mild PTS. In conclusion, our retrospective cohort study of patients with UEDVT showed that treatment restored venous drainage, with a subsequent low frequency of mild PTS at follow-up. Early intervention with CDT prevented bleeding complications.

  6. Pulse Star inertial confinement fusion reactor

    International Nuclear Information System (INIS)

    Blink, J.A.; Hogan, W.J.

    1985-01-01

    Pulse Star is a pool-type ICF reactor that emphasizes low cost and high safety levels. The reactor consists of a vacuum chamber (belljar) submerged in a compact liquid metal (Li 17 Pb 83 or lithium) pool which also contains the heat exchangers and liquid metal pumps. The shielding efficiency of the liquid metal pool is high enough to allow hands-on maintenance of (removed) pumps and heat exchangers. Liquid metal is allowed to spray through the 5.5 m radius belljar at a controlled rate, but is prohibited from the target region by a 4 m radius mesh first wall. The wetted first wall absorbs the fusion x-rays and debris while the spray region absorbs the fusion neutrons. The mesh allows vaporized liquid metal to blow through to the spray region where it can quickly cool and condense. Preliminary calculations show that a 2 m thick first wall could handle the mechanical (support, buckling, and x-ray-induced hoop) loads. Wetting and gas flow issues are in an initial investigation stage

  7. Clinical-Radiological Parameters Improve the Prediction of the Thrombolysis Time Window by Both MRI Signal Intensities and DWI-FLAIR Mismatch.

    Science.gov (United States)

    Madai, Vince Istvan; Wood, Carla N; Galinovic, Ivana; Grittner, Ulrike; Piper, Sophie K; Revankar, Gajanan S; Martin, Steve Z; Zaro-Weber, Olivier; Moeller-Hartmann, Walter; von Samson-Himmelstjerna, Federico C; Heiss, Wolf-Dieter; Ebinger, Martin; Fiebach, Jochen B; Sobesky, Jan

    2016-01-01

    With regard to acute stroke, patients with unknown time from stroke onset are not eligible for thrombolysis. Quantitative diffusion weighted imaging (DWI) and fluid attenuated inversion recovery (FLAIR) MRI relative signal intensity (rSI) biomarkers have been introduced to predict eligibility for thrombolysis, but have shown heterogeneous results in the past. In the present work, we investigated whether the inclusion of easily obtainable clinical-radiological parameters would improve the prediction of the thrombolysis time window by rSIs and compared their performance to the visual DWI-FLAIR mismatch. In a retrospective study, patients from 2 centers with proven stroke with onset value/mean value of the unaffected hemisphere). Additionally, the visual DWI-FLAIR mismatch was evaluated. Prediction of the thrombolysis time window was evaluated by the area-under-the-curve (AUC) derived from receiver operating characteristic (ROC) curve analysis. Factors such as the association of age, National Institutes of Health Stroke Scale, MRI field strength, lesion size, vessel occlusion and Wahlund-Score with rSI were investigated and the models were adjusted and stratified accordingly. In 82 patients, the unadjusted rSI measures DWI-mean and -SD showed the highest AUCs (AUC 0.86-0.87). Adjustment for clinical-radiological covariates significantly improved the performance of FLAIR-mean (0.91) and DWI-SD (0.91). The best prediction results based on the AUC were found for the final stratified and adjusted models of DWI-SD (0.94) and FLAIR-mean (0.96) and a multivariable DWI-FLAIR model (0.95). The adjusted visual DWI-FLAIR mismatch did not perform in a significantly worse manner (0.89). ADC-rSIs showed fair performance in all models. Quantitative DWI and FLAIR MRI biomarkers as well as the visual DWI-FLAIR mismatch provide excellent prediction of eligibility for thrombolysis in acute stroke, when easily obtainable clinical-radiological parameters are included in the prediction

  8. Spray cooling

    International Nuclear Information System (INIS)

    Rollin, Philippe.

    1975-01-01

    Spray cooling - using water spraying in air - is surveyed as a possible system for make-up (peak clipping in open circuit) or major cooling (in closed circuit) of the cooling water of the condensers in thermal power plants. Indications are given on the experiments made in France and the systems recently developed in USA, questions relating to performance, cost and environmental effects of spray devices are then dealt with [fr

  9. Spray boom for selectively spraying a herbicidal composition onto dicots

    DEFF Research Database (Denmark)

    2012-01-01

    There is provided a method and spray boom for discriminating cereal crop (monocot) and weeds (dicots). The spray boom includes means for digitally recording an image of a selected area to be treated by a nozzle on the spray boom, whereby a plant material is identified based on a segmentation proc...

  10. Intra-arterial thrombolysis using rt-PA in patients with acute stroke due to vessel occlusion of anterior and/or posterior cerebral circulation

    Energy Technology Data Exchange (ETDEWEB)

    Tountopoulou, Argyro; Ahl, Bjoern; Weissenborn, Karin [Hannover Medical School, Department of Neurology and Clinical Neurophysiology, Hannover (Germany); Becker, Hartmut; Goetz, Friedrich [Hannover Medical School, Department of Neuroradiology, Hannover (Germany)

    2008-01-15

    The aim of our study was to evaluate the safety and efficacy of intra-arterial (IA) thrombolysis using recombinant tissue plasminogen activator (rt-PA) in patients with acute stroke due to occlusion in the anterior or posterior circulation. We retrospectively analyzed the clinical and radiological data of 88 consecutive patients with acute ischemic stroke who underwent emergency cerebral angiography for the purpose of subsequent IA thrombolysis. The neurological deficit on admission and discharge was graded using the National Institutes of Health Stroke Scale (NIHSS) score. Baseline computer tomography (CT) scans were examined for any signs indicative of cerebral ischemia. The angiographic findings were classified according to the Thrombolysis in Myocardial Infarction (TIMI) score for myocardial infarction. Follow-up CT scans were examined for hemorrhagic complication. Of the 88 patients who underwent IA thrombolysis, 63 presented with complete or partial arterial occlusion in the suspected perfusion area. In these 63 patients, the median NIHSS score dropped from 15 points on admission to 10 points at discharge. The recanalization rate was 52.6% for partial and complete reperfusion. In-hospital mortality was 20.6% (9.1% for carotid, 44.4% for basilar territory occlusion). Intracerebral bleeding (ICB) occurred in 38.6% of the patients with occlusion in the anterior circulation, resulting in these patients presenting a worse clinical outcome than those without ICB. Only minor extracranial bleedings occurred in 20.6% of patients. Patients with ICB had a significantly higher frequency of ischemic signs on the baseline CT scan. Occlusion of a cerebral artery is present in about 75% of the patients eligible for thrombolytic therapy. Intra-arterial thrombolysis using rt-PA in patients with acute ischemic stroke can achieve re-vascularization, although ICB remains the major risk factor affecting its efficacy. (orig.)

  11. Intra-arterial thrombolysis using rt-PA in patients with acute stroke due to vessel occlusion of anterior and/or posterior cerebral circulation

    International Nuclear Information System (INIS)

    Tountopoulou, Argyro; Ahl, Bjoern; Weissenborn, Karin; Becker, Hartmut; Goetz, Friedrich

    2008-01-01

    The aim of our study was to evaluate the safety and efficacy of intra-arterial (IA) thrombolysis using recombinant tissue plasminogen activator (rt-PA) in patients with acute stroke due to occlusion in the anterior or posterior circulation. We retrospectively analyzed the clinical and radiological data of 88 consecutive patients with acute ischemic stroke who underwent emergency cerebral angiography for the purpose of subsequent IA thrombolysis. The neurological deficit on admission and discharge was graded using the National Institutes of Health Stroke Scale (NIHSS) score. Baseline computer tomography (CT) scans were examined for any signs indicative of cerebral ischemia. The angiographic findings were classified according to the Thrombolysis in Myocardial Infarction (TIMI) score for myocardial infarction. Follow-up CT scans were examined for hemorrhagic complication. Of the 88 patients who underwent IA thrombolysis, 63 presented with complete or partial arterial occlusion in the suspected perfusion area. In these 63 patients, the median NIHSS score dropped from 15 points on admission to 10 points at discharge. The recanalization rate was 52.6% for partial and complete reperfusion. In-hospital mortality was 20.6% (9.1% for carotid, 44.4% for basilar territory occlusion). Intracerebral bleeding (ICB) occurred in 38.6% of the patients with occlusion in the anterior circulation, resulting in these patients presenting a worse clinical outcome than those without ICB. Only minor extracranial bleedings occurred in 20.6% of patients. Patients with ICB had a significantly higher frequency of ischemic signs on the baseline CT scan. Occlusion of a cerebral artery is present in about 75% of the patients eligible for thrombolytic therapy. Intra-arterial thrombolysis using rt-PA in patients with acute ischemic stroke can achieve re-vascularization, although ICB remains the major risk factor affecting its efficacy. (orig.)

  12. Reduction of spray pressure leads to less emission and better deposition of spray liquid at high-volume spraying in greenhouse tomato

    NARCIS (Netherlands)

    Os, van E.A.; Michielsen, J.M.G.P.; Corver, F.J.M.; Berg, van den J.V.; Bruins, M.A.; Porskamp, H.A.J.; Zande, van de J.C.

    2005-01-01

    In an experimental greenhouse, growing a tomato crop, it was investigated if a reduction in spray pressure could improve the spray result, while, simultaneously, emission to the ground could be reduced. Spray deposition on the leaves and the emission to the ground was evaluated at different spray

  13. An electrothermal chemical technology for thermal spray coatings

    International Nuclear Information System (INIS)

    Wald, S.; Appelbaum, G.; Alimi, R.; Rabani, L.; Zoler, D.; Zhitomirsky, V.; Factor, M.; Roman, I.

    1998-01-01

    A new spray technology for producing hard-coatings, has been developed at the SOREQ Nuclear Research Center. The concept is based on the extensive experience accumulated at SOREQ in the course of the development of Electrothermal (ET), Electrothermal-Chemical (ETC) and Solid-Propellant Electrothermal-Chemical (SPETC) guns(r). High quality coatings may be obtained by thermal spraying powder particles onto a variety of substrates. Mature state-of-the-art technologies such as plasma spray, high velocity oxy fuel (HVOF) and detonation gun (D-Gun) are widely used for many applications. As each method has its own drawbacks there is a need for a combination of several parameters which cannot be achieved by any existing individual commercial technology. The method presented is oriented toward a high-quality, multi-step, high-throughput, easily programmable continuous coating process and relatively inexpensive technology. The combustion products of a solid or liquid propellant accelerate the powder particles of the coating material. A pulsed-plasma jet, provided by a confined capillary discharge, ignites the propellant and controls the combustion process. The powder particles are accelerated to velocities over 1000 m/s. Due to the very high carrier gas density, high velocity, high throughput and high powder consumption efficiency are obtained. The plasma jet enables control of the gas temperature and consequently influences the powder temperature

  14. Thrombolysis in Stroke within 30 Minutes: Results of the Acute Brain Care Intervention Study

    NARCIS (Netherlands)

    Zinkstok, Sanne M.; Beenen, Ludo F.; Luitse, Jan S.; Majoie, Charles B.; Nederkoorn, Paul J.; Roos, Yvo B.

    2016-01-01

    Time is brain: benefits of intravenous thrombolysis (IVT) in ischemic stroke last for 4.5 hours but rapidly decrease as time progresses following symptom onset. The goal of the Acute Brain Care (ABC) intervention study was to reduce the door-to-needle time (DNT) to ≤30 minutes by optimizing

  15. Improvement of the inlet system for the spray-jet technique for use in spectroscopic studies and molecular deposition

    International Nuclear Information System (INIS)

    Yamada, Toshiki; Shinohara, Hidenori; Mashiko, Shinro

    2006-01-01

    We previously developed a molecular beam apparatus with a spray-jet technique in order to produce a molecular beam of non-volatile molecules in vacuum from the sprayed mist of a sample solution. The apparatus is for use in spectroscopic studies or a means of molecular deposition. The spray-jet inlet system consisted of an ultrasonic nebulizer, an inlet chamber and a pulsed nozzle. In the present paper, further improvements to the spray-jet inlet system are reported. The main improvement is the introduction of a pneumatic nebulizer to replace the previous ultrasonic nebulizer. The efficiency of molecular beam generation was evaluated on the basis of the signal intensity of the resonantly enhanced multiphoton ionization time-of-flight mass (REMPI-TOFMS) spectra for a Rhodamine B/methanol solution and the amount of sample consumed. The introduction of the pneumatic nebulizer increased the efficiency by a factor of 20

  16. Noninvasive treatment of deep venous thrombosis using pulsed ultrasound cavitation therapy (histotripsy) in a porcine model.

    Science.gov (United States)

    Maxwell, Adam D; Owens, Gabe; Gurm, Hitinder S; Ives, Kimberly; Myers, Daniel D; Xu, Zhen

    2011-03-01

    This study evaluated histotripsy as a noninvasive, image-guided method of thrombolysis in a porcine model of deep vein thrombosis. Histotripsy therapy uses short, high-intensity, focused ultrasound pulses to cause mechanical breakdown of targeted soft tissue by acoustic cavitation, which is guided by real-time ultrasound imaging. This is an in vivo feasibility study of histotripsy thrombolysis. Acute thrombi were formed in the femoral vein of juvenile pigs weighing 30-40 kg by balloon occlusion with two catheters and thrombin infusion. A 10-cm-diameter 1-MHz focused transducer was used for therapy. An 8-MHz ultrasound imager was used to align the clot with the therapy focus. Therapy consisted of five cycle pulses delivered at a rate of 1 kHz and peak negative pressure between 14 and 19 MPa. The focus was scanned along the long axis of the vessel to treat the entire visible clot during ultrasound exposure. The targeted region identified by a hyperechoic cavitation bubble cloud was visualized via ultrasound during treatment. Thrombus breakdown was apparent as a decrease in echogenicity within the vessel in 10 of 12 cases and in 7 cases improved flow through the vein as measured by color Doppler. Vessel histology found denudation of vascular endothelium and small pockets of hemorrhage in the vessel adventitia and underlying muscle and fatty tissue, but perforation of the vessel wall was never observed. The results indicate histotripsy has potential for development as a noninvasive treatment for deep vein thrombosis. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  17. Effects of nozzle type and spray angle on spray deposition in ivy pot plants.

    Science.gov (United States)

    Foqué, Dieter; Nuyttens, David

    2011-02-01

    Fewer plant protection products are now authorised for use in ornamental growings. Frequent spraying with the same product or a suboptimal technique can lead to resistance in pests and diseases. Better application techniques could improve the sustainable use of the plant protection products still available. Spray boom systems--instead of the still predominantly used spray guns--might improve crop protection management in greenhouses considerably. The effect of nozzle type, spray pressure and spray angle on spray deposition and coverage in ivy pot plants was studied, with a focus on crop penetration and spraying the bottom side of the leaves in this dense crop. The experiments showed a significant and important effect of collector position on deposition and coverage in the plant. Although spray deposition and coverage on the bottom side of the leaves are generally low, they could be improved 3.0-4.9-fold using the appropriate application technique. When using a spray boom in a dense crop, the nozzle choice, spray pressure and spray angle should be well considered. The hollow-cone, the air-inclusion flat-fan and the standard flat-fan nozzle with an inclined spray angle performed best because of the effect of swirling droplets, droplets with a high momentum and droplet direction respectively. Copyright © 2010 Society of Chemical Industry.

  18. Formulation and evaluation of two-pulse drug delivery system of ...

    African Journals Online (AJOL)

    Purpose: To develop a pH-controlled two-pulse drug delivery system of amoxicillin in order to overcome the snag of biological tolerance and to improve bactericidal activity. Methods: The core tablets were compressed and coated with hydroxylpropyl methylcellulose (HPMC) of different viscosities with spray-dried lactose ...

  19. Upper limb artery segmental occlusions due to chronic use of ergotamine combined with itraconazole, treated by thrombolysis

    Directory of Open Access Journals (Sweden)

    Nodari Franco

    2011-08-01

    Full Text Available Abstract Background The ergotamine tartrate associated with certain categories of drugs can lead to critical ischemia of the extremities. Discontinuation of taking ergotamine is usually sufficient for the total regression of ischemia, but in some cases it could be necessary thrombolytic and anticoagulant therapy to avoid amputation. Case report A woman of 62 years presented with a severe pain left forearm appeared 10 days ago, with a worsening trend. The same symptoms appeared after 5 days also in the right forearm. Physical examination showed the right arm slightly hypothermic, with radial reduced pulse in presence of reduced sensitivity. The left arm was frankly hypothermic, pulse less on radial and with an ulnar humeral reduced pulse, associated to a decreased sensitivity and motility. Clinical history shows a chronic headache for which the patient took a daily basis for years Cafergot suppository (equivalent to 3.2 mg of ergotamine. From about ten days had begun therapy with itraconazole for vaginal candidiasis. The Color-Doppler ultrasound shown arterial thrombosis of the upper limbs (humeral and radial bilateral, with minimal residual flow to the right and no signal on the humeral and radial left artery. Results Angiography revealed progressive reduction in size of the axillary artery and right humeral artery stenosis with right segmental occlusions and multiple hypertrophic collateral circulations at the elbow joint. At the level of the right forearm was recognizable only the radial artery, decreased in size. Does not recognize the ulnar, interosseous artery was thin. To the left showed progressive reduction in size of the distal subclavian and humeral artery, determined by multiple segmental steno-occlusion with collateral vessels serving only a thin hypotrophic interosseous artery. Arteriographic findings were compatible with systemic drug-induced disease. The immediate implementation of thrombolysis, continued for 26 hours, with

  20. Spray drift of pesticides and stream macroinvertebrates: Experimental evidence of impacts and effectiveness of mitigation measures

    Energy Technology Data Exchange (ETDEWEB)

    Maltby, Lorraine [Department of Animal and Plant Sciences, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom)], E-mail: l.maltby@sheffield.ac.uk; Hills, Louise [Department of Animal and Plant Sciences, University of Sheffield, Western Bank, Sheffield S10 2TN (United Kingdom)

    2008-12-15

    Impoverished stream communities in agricultural landscapes have been associated with pesticide contamination, but conclusive evidence of causality is rare. We address this deficiency by adopting an experimental approach to investigate the effects of the insecticides cypermethrin and chlorpyrifos on benthic macroinvertebrates. Three treatments were established and a combination of biomarker, bioassay and biomonitoring approaches was employed to investigate, individual, population and community-level effects. Animals deployed during pesticide application had altered enzyme activity, depressed feeding rate and reduced survival, but these effects were only observed where pesticide was sprayed to the stream edge. There were no clear pesticide-related effects on macroinvertebrate community structure or on the population densities of individual species. Hence, short-term pesticide exposure did cause individual-level effects in stream macroinvertebrates, but these were not translated to effects at the population or community-level and were effectively mitigated by the adoption of a no-spray buffer zone. - Pulsed pesticide exposures via spray drift adversely affected stream invertebrates but did not cause population or community-level effects and were mitigated by no-spray buffer zones.

  1. The Risk of Hemorrhagic Transformation After Thrombolysis for Acute Ischemic Stroke in Chinese Versus North Americans: A Comparative Study.

    Science.gov (United States)

    Xu, Xiaomeng; Wang, Deren; Wang, Fang; Norton, Casey; Liu, Xinfeng; Selim, Magdy

    2018-05-16

    There is a widespread belief that Asians are more susceptible to hemorrhagic transformation (HT) after receiving recombinant tissue-type plasminogen activator (rt-PA) for acute ischemic stroke (AIS). However, this has not been examined in clinical practice. This study aims to compare the incidence of symptomatic hemorrhagic transformation (SHT) among thrombolysis-treated AIS patients in China and in the United States. We compared 212 consecutive patients receiving thrombolysis within 4.5 hours of onset ± endovascular therapy from an American (n = 86) and a Chinese Stroke Center (n = 126). SHT was defined using various definitions based on the National Institute for Neurological Disorders and Stroke Recombinant Tissue Plasminogen Activator (NINDS rt-PA) trials, European-Australian Cooperative Acute Stroke Study 2 (ECASS2), and a modified version of Safe Implementation of Thrombolysis in Stroke-Monitoring Study (mSITS-MOST) study criteria. We used Firth logistic regression to adjust for confounding variables and to identify potential predictors. American patients were older, and had higher prevalence of diabetes, hypertension, cardiac disease, and prestroke use of antithrombotics. They also had higher baseline serum glucose, shorter onset-to-treatment time, and fewer endovascular treatments. The rates of SHT were higher in the American cohort compared to the Chinese cohort: 18.6% versus 14.3% based on NINDS definition of SHT; 15.1% versus 12.7% based on ECASS2; and 11.6% versus 7.2% based on mSITS-MOST. However, none of these differences were significant (unadjusted and adjusted P values > .05). Fatal HT was comparable in Americans versus Chinese (8.1% versus 8.7%). Serum glucose emerged as an independent predictor of SHT (P = .024). In our cohorts, the rate of SHT after thrombolysis is equivalent between Chinese and North American stroke patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Laser Processing of Multilayered Thermal Spray Coatings: Optimal Processing Parameters

    Science.gov (United States)

    Tewolde, Mahder; Zhang, Tao; Lee, Hwasoo; Sampath, Sanjay; Hwang, David; Longtin, Jon

    2017-12-01

    Laser processing offers an innovative approach for the fabrication and transformation of a wide range of materials. As a rapid, non-contact, and precision material removal technology, lasers are natural tools to process thermal spray coatings. Recently, a thermoelectric generator (TEG) was fabricated using thermal spray and laser processing. The TEG device represents a multilayer, multimaterial functional thermal spray structure, with laser processing serving an essential role in its fabrication. Several unique challenges are presented when processing such multilayer coatings, and the focus of this work is on the selection of laser processing parameters for optimal feature quality and device performance. A parametric study is carried out using three short-pulse lasers, where laser power, repetition rate and processing speed are varied to determine the laser parameters that result in high-quality features. The resulting laser patterns are characterized using optical and scanning electron microscopy, energy-dispersive x-ray spectroscopy, and electrical isolation tests between patterned regions. The underlying laser interaction and material removal mechanisms that affect the feature quality are discussed. Feature quality was found to improve both by using a multiscanning approach and an optional assist gas of air or nitrogen. Electrically isolated regions were also patterned in a cylindrical test specimen.

  3. Integrated thermal control and system assessment in plug-chip spray cooling enclosure

    International Nuclear Information System (INIS)

    Zhang, Wei-Wei; Cheng, Wen-Long; Shao, Shi-Dong; Jiang, Li-Jia; Hong, Da-Liang

    2016-01-01

    Highlights: • A novel multi-heat source plug-chip spray cooling enclosure was designed. • Enhanced surfaces with different geometric were analyzed in integrated enclosure. • Overall thermal control with adjustable parameters in enclosure was studied. • Temperature disequilibrium of multi-heat source in enclosure was tested. • A comprehensive assessment system used to evaluate the practicality was proposed. - Abstract: Practical and integrated spray cooling system is urgently needed for the cooling of high-performance electronic chips due to the growth requirements of thermal management in workstation. The integration of multi heat sources and the management of integral system are particularly lacking. In order to fill the vacancies in the study of plug-chip spray cooling, an integrated cooling enclosure was designed in this paper. Multi heat sources were placed in sealed space and the heat was removed by spray. The printed circuit board plug-ins and radio frequency resistors were used as analog motherboards and chips, respectively. The enhanced surfaces with four different geometries and the plain surface were studied under the conditions of different inclination angles. The results were compared and the maximum critical heat flux (CHF) was obtained. Moreover, with the intention of the overall management of multi-heat source in integrated enclosure, the effect of the flow rate and the temperature disequilibrium, and the pulse heating in the process of transient cooling were also analyzed. In addition, a comprehensive assessment system, used to evaluate the practicality of spray cooling experimental devices, was proposed and the performance of enclosure was evaluated.

  4. Influence of arterial occlusion on outcome after intravenous thrombolysis for acute ischemic stroke.

    Science.gov (United States)

    Medlin, Friedrich; Amiguet, Michael; Vanacker, Peter; Michel, Patrik

    2015-01-01

    We aimed to assess the interaction between intravenous thrombolysis (IVT) and arterial occlusion on acute cervicocerebral computed tomographic angiography on the outcome of patients with acute ischemic stroke. Patients from the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) registry with onset-to-door-time ≤4 hours, acute cervicocerebral computed tomographic angiography, a premorbid modified Rankin Scale ≤2, and a National Institute of Health Stroke Scale (NIHSS) >4 were selected. Patients with significant intracranial arterial obstruction (≥50%-99%) and undergoing acute endovascular treatment were excluded. An interaction analysis of IVT and initial arterial occlusion for favorable 3 months outcome (modified Rankin Scale <3) were performed with adjustment for potential confounders. Among 654 included patients, 382 (58%) showed arterial occlusion, of whom 263 (69%) received IVT. Two hundred seventy-two showed no/minimal obstruction of whom 139 (51%) received IVT. In the adjusted interaction analysis, there was a trend in favor of the arterial occlusion group (odds ratio [OR]=3.97; 95% confidence interval [CI], 0.83-18.97; P=0.08). IVT (versus no IVT) was associated with better outcome in patients with occlusion (adjusted OR for favorable outcome, 3.01; 95% CI, 1.10-8.28) but not in patients with no/minimal obstruction (OR, 0.76; 95% CI, 0.21-2.74). Conversely, patients with occlusion had a similar rate of favorable outcome as no/minimal obstruction when thrombolysed (OR, 0.5; 95% CI, 0.17-1.47) but had a less favorable outcome without thrombolysis (OR, 0.13; 95% CI, 0.04-0.44). In this retrospective analysis of consecutive patients with acute ischemic stroke, there was a trend for more favorable outcomes with IVT in the setting of initial arterial occlusion than in the setting of no/minimal obstruction. Before confirmation in randomized controlled studies, this information should not influence thrombolysis decisions, however. © 2014 American Heart

  5. Experimental analysis on the influence of nozzle geometry over the dispersion of liquid n-dodecane sprays

    Directory of Open Access Journals (Sweden)

    Raul ePayri

    2015-10-01

    Full Text Available Understanding and controlling mixing and combustion processes is fundamental in order to face the challenges set by the ever more demanding pollutant regulations and fuel consumption standards of direct injection diesel engines. The fundamentals of these processes haven been long studied by the diesel spray community from both experimental and numerical perspectives. However, certain topics such as the influence of nozzle geometry over the spray atomization, mixing and combustion process are still not completely well understood and predicted by numerical models. The present study seeks to contribute to the current understanding of this subject, by performing state-of-the-art optical diagnostics to liquid sprays injected through two singe-hole nozzles of different conicity. The experiments were carried out in a nitrogen-filled constant-pressure-flow facility. Back pressures were set to produce the desired engine-like density conditions in the chamber, at room temperature. The experimental setup consists in a diffused back illumination setup with a fast pulsed LED light source and a high-speed camera. The diagnostics focused on detecting the liquid spray contour and evaluating the influence of nozzle geometry over the time-resolved and quasi-steady response of the spray dispersion, at similar injection conditions. Results show a clear influence of nozzle geometry on spray contour fluctuations, where the cylindrical nozzle seems to produce larger dispersion in both time-resolved fluctuations and quasi-steady values, when compared to the conical nozzle. This evidences that the turbulence and radial velocity profiles originated at the cylindrical nozzle geometry are able to affect not only the microscopic scales inside the nozzle, but also macroscopic scales such as the steady spray. Observations from this study indicate that the effects of the flow characteristics within the nozzle are carried on to the first millimeters of the spray, in which the

  6. Reactor container spray device

    International Nuclear Information System (INIS)

    Yanai, Ryoichi.

    1980-01-01

    Purpose: To enable decrease in the heat and the concentration of radioactive iodine released from the reactor vessel into the reactor container in the spray device of BWR type reactors. Constitution: A plurality of water receiving trays are disposed below the spray nozzle in the dry well and communicated to a pressure suppression chamber by way of drain pipeways passing through a diaphragm floor. When the recycling system is ruptured and coolants in the reactor vessel and radioactive iodine in the reactor core are released into the dry well, spray water is discharged from the spray nozzle to eliminate the heat and the radioactive iodine in the dry well. In this case, the receiving trays collect the portions of spray water whose absorption power for the heat and radioactive iodine is nearly saturated and falls them into the pool water of the pressure suppression chamber. Consequently, other portions of the spray water that still possess absorption power can be jetted with no hindrance, to increase the efficiency for the removal of the heat and iodine of the spray droplets. (Horiuchi, T.)

  7. Slurry spray distribution within a simulated laboratory scale spray dryer

    International Nuclear Information System (INIS)

    Bertone, P.C.

    1979-01-01

    It was found that the distribution of liquid striking the sides of a simulated room temperature spray dryer was not significantly altered by the choice of nozles, nor by a variation in nozzle operating conditions. Instead, it was found to be a function of the spray dryer's configuration. A cocurrent flow of air down the drying cylinder, not possible with PNL's closed top, favorably altered the spray distribution by both decreasing the amount of liquid striking the interior of the cylinder from 72 to 26% of the feed supplied, and by shifting the zone of maximum impact from 1.0 to 1.7 feet from the nozzle. These findings led to the redesign of the laboratory scale spray dryer to be tested at the Savannah River Plant. The diameter of the drying chamber was increased from 5 to 8 inches, and a cocurrent flow of air was established with a closed recycle. Finally, this investigation suggested a drying scheme which offers all the advantages of spray drying without many of its limitations

  8. Plasma Sprayed Hydroxyapatite Coatings: Influence of Spraying Power on Microstructure

    International Nuclear Information System (INIS)

    Mohd, S. M.; Abd, M. Z.; Abd, A. N.

    2010-01-01

    The plasma sprayed hydroxyapatite (HA) coatings are used on metallic implants to enhance the bonding between the implant and bone in human body. The coating process was implemented at different spraying power for each spraying condition. The coatings formed from a rapid solidification of molten and partly molten particles that impact on the surface of substrate at high velocity and high temperature. The study was concentrated on different spraying power that is between 23 to 31 kW. The effect of different power on the coatings microstructure was investigated using scanning electron microscope (SEM) and phase composition was evaluated using X-ray diffraction (XRD) analysis. The coatings surface morphology showed distribution of molten, partially melted particles and some micro-cracks. The produced coatings were found to be porous as observed from the cross-sectional morphology. The coatings XRD results indicated the presence of crystalline phase of HA and each of the patterns was similar to the initial powder. Regardless of different spraying power, all the coatings were having similar XRD patterns.

  9. Validation of minor stroke definitions for thrombolysis decision making.

    Science.gov (United States)

    Park, Tai Hwan; Hong, Keun-Sik; Choi, Jay Chol; Song, Pamela; Lee, Ji Sung; Lee, Juneyoung; Park, Jong-Moo; Kang, Kyusik; Lee, Kyung Bok; Cho, Yong-Jin; Saposnik, Gustavo; Han, Moon-Ku; Bae, Hee-Joon

    2013-05-01

    Patients with low National Institutes of Health Stroke Scale (NIHSS) scores are frequently excluded from thrombolysis, but more than 25% of them remain disabled. We sought to define a validated minor stroke definition to reduce the inappropriate treatment exclusion. From an outcome database, untreated patients with an NIHSS score of 5 or less presenting within a 4.5-hour window were identified and 3-month modified Rankin Scale (mRS) outcomes were analyzed according to individual isolated symptoms and total NIHSS scores. The validity of the following minor stroke definitions were assessed: (1) the National Institute of Neurological Disorders and Stroke Tissue Plasminogen Activator (NINDS-TPA) trials' definition, (2) the total NIHSS score, varying a cutoff point from 0 to 4, and (3) our proposed definition that included an NIHSS score = 0 or an NIHSS score = 1 on the items of level of consciousness (LOC), gaze, facial palsy, sensory, or dysarthria. Of 647 patients, 172 patients (26.6%) had a 3-month unfavorable outcome (mRS score 2-6). Favorable outcome was achieved in more than 80% of patients with an NIHSS score of 1 or less or with an isolated symptom on the LOC, gaze, facial palsy, sensory, or dysarthria item. In contrast, unfavorable outcome proportion was more than 25% in patients with an NIHSS score of 2 or more. When the NINDS-TPA trials' definition, our definition, or the definition of an NIHSS score of 1 or less were applied, more than 75% of patients with an unfavorable outcome were defined as a non-minor stroke and less than 15% of patients with an unfavorable outcome were defined as a minor stroke. Implementation of an optimal definition of minor stroke into thrombolysis decision-making process would decrease the unfavorable outcomes in patients with low NIHSS scores. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Thrombolysis outcomes in acute ischemic stroke patients with prior stroke and diabetes mellitus

    DEFF Research Database (Denmark)

    Mishra, N K; Ahmed, N; Davalos, A

    2011-01-01

    BACKGROUND: Patients with concomitant diabetes mellitus (DM) and prior stroke (PS) were excluded from European approval of alteplase in stroke. We examined the influence of DM and PS on the outcomes of patients who received thrombolytic therapy (T; data from Safe Implementation of Thrombolysis......,986), or concomitant DM and PS (OR 1.23 [0.996-1.52], p = 0.05, n = 1,136), all CMH p treatment (tissue...

  11. CONCHAS-SPRAY, Reactive Flows with Fuel Sprays

    International Nuclear Information System (INIS)

    Cloutman, L.D.; Dukowicz, J.K.; Ramshaw, J.D.; Amsden, A.A.

    2001-01-01

    Description of program or function: CONCHAS-SPRAY solves the equations of transient, multicomponent, chemically reactive fluid dynamics, together with those for the dynamics of an evaporating liquid spray. The program was developed with applications to internal combustion engines in mind. The formulation is spatially two-dimensional, and encompasses both planar and axisymmetric geometries. In the latter case, the flow is permitted to swirl about the axis of symmetry. CONCHAS-SPRAY is a time-marching, finite- difference program that uses a partially implicit numerical scheme. Spatial differences are formed with respect to a generalized two- dimensional mesh of arbitrary quadrilaterals whose corner locations are specified functions of time. This feature allows a Lagrangian, Eulerian, or mixed description, and is particularly useful for representing curved or moving boundary surfaces. Arbitrary numbers of species and chemical reactions are allowed. The latter are subdivided into kinetic and equilibrium reactions, which are treated by different algorithms. A turbulent law-of-the-wall boundary layer option is provided. CONCHAS-SPRAY calls a number of LANL system subroutines to display graphic or numerical information on microfiche. These routines are not included, but are described in the reference report. Several routines called from LINPACK and SLATEC1.0 are included

  12. Successful treatment of massive pulmonary embolism with prolonged catheter-directed thrombolysis.

    LENUS (Irish Health Repository)

    Kelly, Peter

    2012-02-03

    This is a case report of a young woman who presented with an extensive pulmonary embolism and echocardiographic evidence of right ventricular dysfunction. Although hemodynamically stable, the patient\\'s clinical condition failed to improve with standard heparin anticoagulation. Successful local catheter-directed thrombolysis was performed over an extended period of 48 h with regular monitoring of response to therapy by computed tomography-pulmonary angiography and echocardiography. To our knowledge, treatment of a pulmonary embolism by catheter-directed thrombolytic infusion over an extended period of 48 h has not previously been described.

  13. Numerical modelling of fuel sprays

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, C.

    1999-06-01

    The way the fuel is introduced into the combustion chamber is one of the most important parameters for the power output and the generation of emissions in the combustion of liquid fuels. The interaction between the turbulent gas flow field and the liquid fuel droplets, the vaporisation of them and the mixing of the gaseous fuel with the ambient air that are vital parameters in the combustion process. The use of numerical calculations is an important tool to better understand these complex interacting phenomena. This thesis reports on the numerical modelling of fuel sprays in non-reacting cases using an own developed spray module. The spray module uses the stochastic parcel method to represent the spray. The module was made in such manner that it could by coupled with different gas flow solver. Results obtained from four different gas flow solvers are presented in the thesis, including the use of two different kinds of turbulence models. In the first part the spray module is coupled with a k-{eta} based 2-D cylindrical gas flow solver. A thorough sensitivity analysis was performed on the spray and gas flow solver parameters, such as grid size dependence and sensitivity to initial values of k-{eta}. The results of the spray module were also compared to results from other spray codes, e.g. the well known KIVA code. In the second part of this thesis the spray was injected into a turbulent and fully developed crossflow studied. The spray module was attached to a LES (Large Eddy Simulation) based flow solvers enabling the study of the complex structures and time dependent phenomena involved in spray in crossflows. It was found that the spray performs an oscillatory motion and that the Strouhal number in the wake was about 0.1. Different spray breakup models were evaluated by comparing with experimental results 66 refs, 56 figs

  14. Drug delivery with microsecond laser pulses into gelatin

    Science.gov (United States)

    Shangguan, Hanqun; Casperson, Lee W.; Shearin, Alan; Gregory, Kenton W.; Prahl, Scott A.

    1996-07-01

    Photoacoustic drug delivery is a technique for localized drug delivery by laser-induced hydrodynamic pressure following cavitation bubble expansion and collapse. Photoacoustic drug delivery was investigated on gelatin-based thrombus models with planar and cylindrical geometries by use of one microsecond laser pulses. Solutions of a hydrophobic dye in mineral oil permitted monitoring of delivered colored oil into clear gelatin-based thrombus models. Cavitation bubble development and photoacoustic drug delivery were visualized with flash photography. This study demonstrated that cavitation is the governing mechanism for photoacoustic drug delivery, and the deepest penetration of colored oil in gels followed the bubble collapse. Spatial distribution measurements revealed that colored oil could be driven a few millimeters into the gels in both axial and radial directions, and the penetration was less than 500 mu m when the gelatin structure was not fractured. localized drug delivery, cavitation bubble, laser thrombolysis.

  15. Antibody-targeted thrombus imaging and thrombolysis

    International Nuclear Information System (INIS)

    Wu Guoxin; Ruan Changgeng

    1993-05-01

    In respect of thrombus imaging, the femoral arterial or venous thrombus model was prepared in dogs and imaged with single photon emission computerized tomography (SPECT). After 4 hours of injection of 131 I-SZ-51 the radioactivity ratio between thrombus and blood (T/B) was 18 : 1 and 8 : 1 for arterial and venous thrombus respectively. The result conformed with the T/B ratio of the removed thrombus and blood after 24 hours of injection of radiotracer. It indicates that the McAb SZ-51 has a great potential to bind with thrombus. In respect of thrombolysis, the Fab(fragment, antigen-binding) fragment of McAb SZ-51 was chemically conjugated of urokinase (UK) by the disulfide-linking reagent SPDP and 2-iminothiolane. The resulting conjugate was 3 to 5 times as potent as UK in vitro in human platelet-rich plasma assay. The increase of fibrinolytic potency was accompanied by a decrease of consumption of plasminogen and fibrinogen. It shows that the increase of potency is the result of selectivity increase

  16. [The spectra of a laser-produced plasma source with CO2, O2 and CF4 liquid aerosol spray target].

    Science.gov (United States)

    Ni, Qi-Liang; Chen, Bo

    2008-11-01

    A laser-produced plasma (LPP) source with liquid aerosol spray target and nanosecond laser was developed, based on both soft X-ray radiation metrology and extreme ultraviolet projection lithography (EUVL). The LPP source is composed of a stainless steel solenoid valve whose temperature can be continuously controlled, a Nd : YAG laser with pulse width, working wavelength and pulse energy being 7 ns, 1.064 microm and 1J respectively, and a pulse generator which can synchronously control the valve and the laser. A standard General Valve Corporation series 99 stainless steel solenoid valve with copper gasket seals and a Kel-F poppet are used in order to minimize leakage and poppet deformation during high-pressure cryogenic operation. A close fitting copper cooling jacket surrounds the valve body. The jacket clamps a copper coolant carrying tube 3 mm in diameter, which is fed by an automatically pressurized liquid nitrogen-filled dewar. The valve temperature can be controlled between 77 and 473 K. For sufficiently high backing pressure and low temperature, the valve reservoir gas can undergo a gas-to-liquid phase transition. Upon valve pulsing, the liquid is ejected into a vacuum and breaks up into droplets, which is called liquid aerosol spray target. For the above-mentioned LPP source, firstly, by the use of Cowan program on the basis of non-relativistic quantum mechanics, the authors computed the radiative transition wavelengths and probabilities in soft X-ray region for O4+, O5+, O6+, O7+, F5+, F6+ and F7+ ions which were correspondingly produced from the interaction of the 10(11)-10(12) W x cm(-2) power laser with liquid O2, CO2 and CF4 aerosol spray targets. Secondly, the authors measured the spectra of liquid O2, CO2 and CF4 aerosol spray target LPP sources in the 6-20 nm band for the 8 x 10(11) W x cm(-2) laser irradiance. The measured results were compared with the Cowan calculated results ones, and the radiative transition wavelength and probability for the

  17. Collateral circulation on perfusion-computed tomography-source images predicts the response to stroke intravenous thrombolysis.

    Science.gov (United States)

    Calleja, A I; Cortijo, E; García-Bermejo, P; Gómez, R D; Pérez-Fernández, S; Del Monte, J M; Muñoz, M F; Fernández-Herranz, R; Arenillas, J F

    2013-05-01

    Perfusion-computed tomography-source images (PCT-SI) may allow a dynamic assessment of leptomeningeal collateral arteries (LMC) filling and emptying in middle cerebral artery (MCA) ischaemic stroke. We described a regional LMC scale on PCT-SI and hypothesized that a higher collateral score would predict a better response to intravenous (iv) thrombolysis. We studied consecutive ischaemic stroke patients with an acute MCA occlusion documented by transcranial Doppler/transcranial color-coded duplex, treated with iv thrombolysis who underwent PCT prior to treatment. Readers evaluated PCT-SI in a blinded fashion to assess LMC within the hypoperfused MCA territory. LMC scored as follows: 0, absence of vessels; 1, collateral supply filling ≤ 50%; 2, between> 50% and < 100%; 3, equal or more prominent when compared with the unaffected hemisphere. The scale was divided into good (scores 2-3) vs. poor (scores 0-1) collaterals. The predetermined primary end-point was a good 3-month functional outcome, while early neurological recovery, transcranial duplex-assessed 24-h MCA recanalization, 24-h hypodensity volume and hemorrhagic transformation were considered secondary end-points. Fifty-four patients were included (55.5% women, median NIHSS 10), and 4-13-23-14 patients had LMC score (LMCs) of 0-1-2-3, respectively. The probability of a good long-term outcome augmented gradually with increasing LMCs: (0) 0%; (1) 15.4%; (2) 65.2%; (3) 64.3%, P = 0.004. Good-LMCs was independently associated with a good outcome [OR 21.02 (95% CI 2.23-197.75), P = 0.008]. Patients with good LMCs had better early neurological recovery (P = 0.001), smaller hypodensity volumes (P < 0.001) and a clear trend towards a higher recanalization rate. A higher degree of LMC assessed by PCT-SI predicts good response to iv thrombolysis in MCA ischaemic stroke patients. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  18. Construction of polylysine dendrimer nanocomposites carrying nattokinase and their application in thrombolysis.

    Science.gov (United States)

    Wu, Can; Gao, Chunmei; Lü, Shaoyu; Xu, Xiubin; Wen, Na; Zhang, Shaofei; Liu, Mingzhu

    2018-02-01

    Thrombotic disease has become one of the leading causes of mortality among humans globally. Nattokinase (NK), a novel thrombolytic agent, has attracted the attention of researchers. However, NK is a serine protease that is vulnerable to environmental effects resulting in its inactivation. In this study, polylysine dendrimer (PLLD) was synthesized through divergence-convergence method, and a series of NK/PLLD nanocomposites with different molar ratio was prepared. In addition, NK was successfully incorporated into the cores of PLLD G4 through hydrogen bonds and van der Waals forces. In NK/PLLD nanocomposites, when the molar ratio of NK to PLLD is 1:30, a high relative enzyme activity level (up to 117%) was achieved and was more stable at different temperatures and pH than free NK. In in vitro thrombolysis experiment, compared with free NK, NK/PLLD nanocomposites could control the release of NK. The thrombolysis rate of NK/PLLD nanocomposites reached 50% at 12 h, which can effectively avoid other complications such as hemorrhage. Interestingly, NK/PLLD nanocomposites with positive charge can penetrate into the negatively charged thrombus through electrostatic interaction, thus providing a good thrombolytic effect. Hemolysis and MTT experiments show that PLLD nanomaterials can serve as ideal carriers of protein drugs. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 440-449, 2018. © 2017 Wiley Periodicals, Inc.

  19. Histological and ultrastructural effect of an Nd:YAG pulsed laser beam on dental hard tissue and pulp

    Science.gov (United States)

    Vignato, Costantino; Vignato, Giuseppe; Nardelli, Antonella; Baldan, Arianna; Mason, Pier N.

    1994-09-01

    The purpose of this study was to determine histological and ultrastructural modifications produced by an Nd:YAG pulsed laser beam after an in vivo exposure of human molars. Using a Nd:YAG pulsed laser beam delivered by a 600 micrometers optical fiber and concurrent air and water cooling spray, 14 human third molars with artificial first class cavities were exposed at different power levels (6, 7, and 8 W). All the teeth were extracted at different time periods between 10 and 25 days and prepared for histological examination. The results of the histological examination showed no evidence of degeneration or necrosis of the pulpar tissue. Analysis of the dentinal surfaces after exposure demonstrated that the dentinal tubules are completely closed due to the melted dentin. In conclusion a Nd:YAG pulsed laser beam with an air and water cooling spray is safe for treatments of class I decay and no necrosis or degeneration of the pulp was found for laser powers of 6, 7, and 8 W.

  20. Thermal Arc Spray Overview

    Science.gov (United States)

    Hafiz Abd Malek, Muhamad; Hayati Saad, Nor; Kiyai Abas, Sunhaji; Mohd Shah, Noriyati

    2013-06-01

    Usage of protective coating for corrosion protection was on highly demand during the past decade; and thermal spray coating played a major part during that time. In recent years, the thermal arc spray coating becomes a popular coating. Many big players in oil and gas such as PETRONAS, EXXON MOBIL and SHELL in Malaysia tend to use the coating on steel structure as a corrosion protection. Further developments in coating processes, the devices, and raw materials have led to expansion of functional coatings and applications scope from conventional coating to specialized industries. It is widely used because of its ability to withstand high process temperature, offer advantages in efficiency, lower cost and acts as a corrosion protection. Previous research also indicated that the thermal arc spray offers better coating properties compared to other methods of spray. This paper reviews some critical area of thermal spray coating by discussing the process/parameter of thermal arc spray technology and quality control of coating. Coating performance against corrosion, wear and special characteristic of coating are also described. The field application of arc spray technology are demonstrated and reviewed.

  1. Thermal Arc Spray Overview

    International Nuclear Information System (INIS)

    Malek, Muhamad Hafiz Abd; Saad, Nor Hayati; Abas, Sunhaji Kiyai; Shah, Noriyati Mohd

    2013-01-01

    Usage of protective coating for corrosion protection was on highly demand during the past decade; and thermal spray coating played a major part during that time. In recent years, the thermal arc spray coating becomes a popular coating. Many big players in oil and gas such as PETRONAS, EXXON MOBIL and SHELL in Malaysia tend to use the coating on steel structure as a corrosion protection. Further developments in coating processes, the devices, and raw materials have led to expansion of functional coatings and applications scope from conventional coating to specialized industries. It is widely used because of its ability to withstand high process temperature, offer advantages in efficiency, lower cost and acts as a corrosion protection. Previous research also indicated that the thermal arc spray offers better coating properties compared to other methods of spray. This paper reviews some critical area of thermal spray coating by discussing the process/parameter of thermal arc spray technology and quality control of coating. Coating performance against corrosion, wear and special characteristic of coating are also described. The field application of arc spray technology are demonstrated and reviewed.

  2. Sodium spray release accident analysis for fast reactor safety studies

    International Nuclear Information System (INIS)

    Shire, P.R.

    1976-10-01

    A computer code has been developed to model the effects of postulated sodium spray release from LMFBR piping. The calculation method utilizes gas convection and droplet combustion theory to calculate the pressure and temperature effects in a range of 0 to 21% oxygen. Droplet motion and large aggregate sodium surface area result in rapid release of combustion and sensible heat causing a nearly adiabtic pressure pulse peaking in a matter of seconds. This analytical tool has indicated good agreement with prototypic test data for a range of oxygen concentrations, cell volumes and droplet sizes

  3. AToMS: A Ubiquitous Teleconsultation System for Supporting AMI Patients with Prehospital Thrombolysis

    Directory of Open Access Journals (Sweden)

    Bruno S. P. M. Correa

    2011-01-01

    Full Text Available The latest population-based studies in the medical literature worldwide indicate that acute myocardial infarction (AMI patients still experience prolonged delay to be rescued, which often results in morbidity and mortality. This paper reports from a technological standpoint a teleconsultation and monitoring system named AToMS. This system addresses the problem of prehospital delivery of thrombolysis to AMI patients by enabling the remote interaction of the paramedics and a cardiologist available at a Coronary Care Unit (CCU. Such interaction allows the diagnosis of the patient eligibility to the immediate application of thrombolysis, which is meant to reduce the delay between the onset of symptoms and the eventual application of proper treatment. Such delay reduction is meant to increase the AMI patient's chances of survival and decrease the risks of postinfarction sequels. The teleconsultation is held with the support of wireless and mobile technologies, which also allows the cardiologist to monitor the patient while he/she is being taken to the nearest CCU. All exchanged messages among paramedics and cardiologists are recorded to render an auditable system. AToMS has been deployed in a first stage in the city of Rio de Janeiro, where the medical team involved in the project has conducted commissioned tests.

  4. The growth of nanoscale ZnO films by pulsed-spray evaporation chemical vapor deposition and their structural, electric and optical properties

    International Nuclear Information System (INIS)

    Jiang Yinzhu; Bahlawane, Naoufal

    2010-01-01

    Great interest in nanoscale thin films (sub-100 nm) has been stimulated by the developing demands of functional devices. In this paper, nanoscale zinc oxide (ZnO) thin films were deposited on glass substrates at 300 o C by pulsed-spray evaporation chemical vapor deposition. Scanning electron micrographs indicate uniform surface morphologies composed of nanometer-sized spherical particles. The growth kinetics and growth mode are studied and the relationship between the film thickness and the electric properties with respect to the growth mode is interpreted. X-ray diffraction shows that all ZnO films grown by this process were crystallized in a hexagonal structure and highly oriented with their c-axes perpendicular to the plane of the substrate. Optical measurements show transparencies above 85% in the visible spectral range for all films. The absorbance in the UV spectral range respects well the Beer-Lambert law, enabling an accurate optical thickness measurement, and the absorption coefficient was measured for a selected wavelength. The measured band gap energies exhibit an almost constant value of 3.41 eV for all films with different thicknesses, which attributed to the thickness-independent crystallite size.

  5. Hair spray poisoning

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002705.htm Hair spray poisoning To use the sharing features on this page, please enable JavaScript. Hair spray poisoning occurs when someone breathes in (inhales) ...

  6. Spray rolling aluminum alloy strip

    Energy Technology Data Exchange (ETDEWEB)

    McHugh, Kevin M.; Delplanque, J.-P.; Johnson, S.B.; Lavernia, E.J.; Zhou, Y.; Lin, Y

    2004-10-10

    Spray rolling combines spray forming with twin-roll casting to process metal flat products. It consists of atomizing molten metal with a high velocity inert gas, cooling the resultant droplets in flight and directing the spray between mill rolls. In-flight convection heat transfer from atomized droplets teams with conductive cooling at the rolls to rapidly remove the alloy's latent heat. Hot deformation of the semi-solid material in the rolls results in fully consolidated, rapidly solidified product. While similar in some ways to twin-roll casting, spray rolling has the advantage of being able to process alloys with broad freezing ranges at high production rates. This paper describes the process and summarizes microstructure and tensile properties of spray-rolled 2124 and 7050 aluminum alloy strips. A Lagrangian/Eulerian poly-dispersed spray flight and deposition model is described that provides some insight into the development of the spray rolling process. This spray model follows droplets during flight toward the rolls, through impact and spreading, and includes oxide film formation and breakup when relevant.

  7. Remotely controlled spray gun

    Science.gov (United States)

    Cunningham, William C. (Inventor)

    1987-01-01

    A remotely controlled spray gun is described in which a nozzle and orifice plate are held in precise axial alignment by an alignment member, which in turn is held in alignment with the general outlet of the spray gun by insert. By this arrangement, the precise repeatability of spray patterns is insured.

  8. Comparision on dynamic behavior of diesel spray and rapeseed oil spray in diesel engine

    Science.gov (United States)

    Sapit, Azwan; Azahari Razali, Mohd; Faisal Hushim, Mohd; Jaat, Norrizam; Nizam Mohammad, Akmal; Khalid, Amir

    2017-04-01

    Fuel-air mixing is important process in diesel combustion. It significantly affects the combustion and emission of diesel engine. Biomass fuel has high viscosity and high distillation temperature and may negatively affect the fuel-air mixing process. Thus, study on the spray development and atomization of this type of fuel is important. This study investigates the atomization characteristics and droplet dynamic behaviors of diesel engine spray fuelled by rapeseed oil (RO) and comparison to diesel fuel (GO). Optical observation of RO spray was carried out using shadowgraph photography technique. Single nano-spark photography technique was used to study the characteristics of the spray while dual nano-spark shadowgraph technique was used to study the spray droplet behavior. Using in-house image processing algorithm, the images were processed and the boundary condition of each spray was also studied. The results show that RO has very poor atomization due to the high viscosity nature of the fuel when compared to GO. This is in agreement with the results from spray droplet dynamic behavior studies that shows due to the high viscosity, the RO spray droplets are large in size and travel downward, with very little influence of entrainment effect due to its large kinematic energy.

  9. Thermal spray for commercial shipbuilding

    Science.gov (United States)

    Rogers, F. S.

    1997-09-01

    Thermal spraying of steel with aluminum to protect it from corrosion is a technology that has been proven to work in the marine environment. The thermal spray coating system includes a paint sealer that is applied over the thermally sprayed aluminum. This extends the service life of the coating and provides color to the end product. The thermal spray system protects steel both through the principle of isolation (as in painting) and galvanizing. With this dual protection mechanism, steel is protected from corrosion even when the coating is damaged. The thermal- sprayed aluminum coating system has proved the most cost- effective corrosion protection system for the marine environment. Until recently, however, the initial cost of application has limited its use for general application. Arc spray technology has reduced the application cost of thermal spraying of aluminum to below that of painting. Commercial shipbuilders could use this technology to enhance their market position in the marine industry.

  10. Plasma sprayed TiC coatings for first wall protection in fusion devices

    International Nuclear Information System (INIS)

    Groot, P.; Laan, J.G. van der; Laas, L.; Mack, M.; Dvorak, M.

    1989-01-01

    For protection of plasma facing components in nuclear fusion devices thick titanium carbide coatings are being developed. Coatings have been produced by plasma spraying at atmospheric pressure (APS) and low pressure (LPPS) and analyzed with respect to microstructure and chemical composition. Thermo-mechanical evaluation has been performed by applying short pulse laser heat flux tests. The influence of coating thickness and porosity on the resistance to spalling by thermal shocks appears to be more important than aspects of chemical composition. (author)

  11. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Esch, Jan Schulte am; Hammerschlag, Sascha; Knoefel, Wolfram Trudo; Fuerst, Guenter

    2008-01-01

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  12. Electrostatically atomised hydrocarbon sprays

    Energy Technology Data Exchange (ETDEWEB)

    Yule, A.J.; Shrimpton, J.S.; Watkins, A.P.; Balachandran, W.; Hu, D. [UMIST, Manchester (United Kingdom). Thermofluids Division, Dept. of Mechanical Engineering

    1995-07-01

    A burner using an electrostatic method to produce and control a fuel spray is investigated for non-burning sprays. The burner has a charge injection nozzle and the liquid flow rate and charge injection rate are varied using hydrocarbon liquids of differing viscosities, surface tensions and electrical conductivities (kerosene, white spirit and diesel oil). Droplet size distributions are measured and it is shown how the dropsize, spray pattern, breakup mechanism and breakup length depend on the above variables, and in particular on the specific charge achieved in the spray. The data are valuable for validating two computer models under development. One predicts the electric field and flow field inside the nozzle as a function of emitter potential, geometry and flow rate. The other predicts the effect of charge on spray dispersion, with a view to optimizing spray combustion. It is shown that electrostatic disruptive forces can be used to atomize oils at flow rates commensurate with practical combustion systems and that the charge injection technique is particularly suitable for highly resistive liquids. Possible limitations requiring further research include the need to control the wide spray angle, which may provide fuel-air mixtures too lean near the nozzle, and the need to design for maximum charge injection rate, which is thought to be limited by corona breakdown in the gas near the nozzle orifice. 30 refs., 15 figs., 1 tab.

  13. Influence of spray parameters on the microstructure and mechanical properties of gas-tunnel plasma sprayed hydroxyapatite coatings

    International Nuclear Information System (INIS)

    Morks, M.F.; Kobayashi, Akira

    2007-01-01

    For biomedical applications, hydroxyapatite (HA) coatings were deposited on 304 stainless steel substrate by using a gas tunnel type plasma spraying process. The influences of spraying distances and plasma arc currents on the microstructure, hardness and adhesion properties of HA coatings were investigated. Microstructure observation by SEM showed that HA coatings sprayed at low plasma power have a porous structure and poor hardness. HA coatings sprayed at high plasma power and short spraying distance are characterized by good adhesion and low porosity with dense structure. Hardness increased for HA coatings sprayed at shorter spraying distance and higher plasma power, mainly due to the formation of dense coatings

  14. Effect of X-Ray Attenuation of Arterial Obstructions on Intravenous Thrombolysis and Outcome after Ischemic Stroke.

    Directory of Open Access Journals (Sweden)

    Grant Mair

    Full Text Available To assess whether the x-ray attenuation of intra-arterial obstruction measured on non-contrast CT in ischemic stroke can predict response to thrombolysis and subsequent functional outcome.The Third International Stroke Trial (IST-3 was a multicenter randomized-controlled trial of intravenous thrombolysis (rt-PA given within six hours of ischemic stroke. Ethical approval and informed consent were obtained. In a subgroup of 109 IST-3 patients (38 men, median age 82 years, a single reader, masked to all clinical and other imaging data, manually measured x-ray attenuation (Hounsfield Units, HU on non-contrast CT at the location of angiographically-proven intra-arterial obstructions, pre-randomization and at 24-48 hour follow-up. We calculated change in attenuation between scans. We assessed the impact of pre-randomization arterial obstruction attenuation on six-month functional outcome.Most arterial obstructions (64/109, 59% were hyperattenuating (mean 51.0 HU. Compared with control, treatment with rt-PA was associated with a greater, but non-significant, reduction in obstruction attenuation at follow-up (-8.0 HU versus -1.4 HU in patients allocated control, p = 0.117. In multivariable ordinal regression analysis controlled for patient age, stroke severity, location and extent of obstruction, time from stroke onset to baseline scan and rt-PA treatment allocation, the attenuation of pre-randomization arterial obstruction was not independently associated with six-month outcome (odds ratio = 0.99, 95% confidence interval = 0.94-1.03, p = 0.516.In ischemic stroke, the x-ray attenuation of the arterial obstruction may decline more rapidly from baseline to 24-48 hours following treatment with thrombolysis but we found no evidence that baseline arterial obstruction attenuation predicts six-month outcome.

  15. Particle size distribution of aerosols sprayed from household hand-pump sprays containing fluorine-based and silicone-based compounds.

    Science.gov (United States)

    Kawakami, Tsuyoshi; Isama, Kazuo; Ikarashi, Yoshiaki

    2015-01-01

    Japan has published safety guideline on waterproof aerosol sprays. Furthermore, the Aerosol Industry Association of Japan has adopted voluntary regulations on waterproof aerosol sprays. Aerosol particles of diameter less than 10 µm are considered as "fine particles". In order to avoid acute lung injury, this size fraction should account for less than 0.6% of the sprayed aerosol particles. In contrast, the particle size distribution of aerosols released by hand-pump sprays containing fluorine-based or silicone-based compounds have not been investigated in Japan. Thus, the present study investigated the aerosol particle size distribution of 16 household hand-pump sprays. In 4 samples, the ratio of fine particles in aerosols exceeded 0.6%. This study confirmed that several hand-pump sprays available in the Japanese market can spray fine particles. Since the hand-pump sprays use water as a solvent and their ingredients may be more hydrophilic than those of aerosol sprays, the concepts related to the safety of aerosol-sprays do not apply to the hand pump sprays. Therefore, it may be required for the hand-pump spray to develop a suitable method for evaluating the toxicity and to establish the safety guideline.

  16. Processing Adipose-Rich Mohs Samples: A Comparative Study of Effectiveness of Pretreatment With Liquid Nitrogen Versus Flash Freezing Spray.

    Science.gov (United States)

    Reserva, Jeave; Kozel, Zachary; Krol, Cindy; Speiser, Jodi; Adams, William; Tung, Rebecca

    2017-11-01

    Processing of adipose-rich Mohs micrographic surgery (MMS) specimens poses challenges that may preclude complete margin evaluation. In this setting, the value of additional freezing methods using various cooling agents has not been previously investigated. The aim of this study is to compare the frozen section quality of high-adipose Mohs specimens processed without additional cooling treatments versus those pretreated with 1,1,1,2-tetrafluoroethane (TFE) or liquid nitrogen (LN2). A set of 3 sections were each taken from 24 adipose-rich Mohs micrographic surgery specimens. A section from each set was subjected to either no additional cooling treatment (control), two 10-second pulse sprays of 1,1,1,2-tetrafluoroethane, or three 2-second pulse sprays of LN2. After staining, 2 blinded raters evaluated slide quality based on the presence or absence of the following features: margin completeness, nuclear clearing, epidermal or adipose folding, holes, or venetian blind-like artifacts. Pretreatment of the sample with LN2 produced a significantly (P < 0.001) greater number of high-quality slides (19/24) compared to pretreatment with 1,1,1,2-tetrafluoroethane (1/24) and no additional treatment (0/24). The adjunctive use of LN2 spray before tissue embedding circumvents the challenges of processing "thick" (high-adipose) specimens and facilitates the production of high-quality frozen section slides during Mohs micrographic surgery.

  17. Methodology for estimation of time-dependent surface heat flux due to cryogen spray cooling.

    Science.gov (United States)

    Tunnell, James W; Torres, Jorge H; Anvari, Bahman

    2002-01-01

    Cryogen spray cooling (CSC) is an effective technique to protect the epidermis during cutaneous laser therapies. Spraying a cryogen onto the skin surface creates a time-varying heat flux, effectively cooling the skin during and following the cryogen spurt. In previous studies mathematical models were developed to predict the human skin temperature profiles during the cryogen spraying time. However, no studies have accounted for the additional cooling due to residual cryogen left on the skin surface following the spurt termination. We formulate and solve an inverse heat conduction (IHC) problem to predict the time-varying surface heat flux both during and following a cryogen spurt. The IHC formulation uses measured temperature profiles from within a medium to estimate the surface heat flux. We implement a one-dimensional sequential function specification method (SFSM) to estimate the surface heat flux from internal temperatures measured within an in vitro model in response to a cryogen spurt. Solution accuracy and experimental errors are examined using simulated temperature data. Heat flux following spurt termination appears substantial; however, it is less than that during the spraying time. The estimated time-varying heat flux can subsequently be used in forward heat conduction models to estimate temperature profiles in skin during and following a cryogen spurt and predict appropriate timing for onset of the laser pulse.

  18. Randomized comparison of intra-arterial and intravenous thrombolysis in a canine model of acute basilar artery thrombosis

    International Nuclear Information System (INIS)

    Qureshi, A.I.; Yahia, A.M.; Boulos, A.S.; Hanel, R.A.; Suri, M.F.K.; Hopkins, L.N.; Alberico, R.A.

    2004-01-01

    We compared the rates of recanalization cerebral infarct and hemorrhage between intra-arterial (IA) reteplase and intravenous (IV) alteplase thrombolysis in a canine model of basilar artery thrombosis. Thrombosis was induced by injecting a clot in the basilar artery of 13 anesthetized dogs via superselective catheterization. The animals were randomized in a blinded fashion, 2 h after clot injection and verification of arterial occlusion, to receive IV alteplase 0.9 mg/kg over 60 min and IA placebo, or IA reteplase 0.09 units/kg over 20 min, equivalent to one-half the alteplase dose, and IV placebo. Recanalization was studied for 6 h after treatment with serial angiography; the images were later graded in a blinded fashion. Blinded interpretation of postmortem MRI was performed to assess the presence of brain infarcts and/or hemorrhage. At 3 h after initiation of treatment, partial or complete recanalization was observed in one of six dogs in the IV alteplase group and in five of seven in the IA reteplase group (P = 0.08). At 6 h, no significant difference in partial or complete recanalization was observed between the groups (two of six vs. five of seven; P = 0.20). Postmortem MRI revealed infarcts in four of six animals treated with IV alteplase and three of seven treated with IA reteplase (P = 0.4). Intracerebral hemorrhage was more common in the IV alteplase group (four of six vs. none of seven; P = 0.02). This study thus suggests that IA thrombolysis affords a recanalization rate similar to that of IV thrombolysis, but with a lower rate of intracerebral hemorrhage. (orig.)

  19. Validation of the DRAGON Score in a Chinese Population to Predict Functional Outcome of Intravenous Thrombolysis-Treated Stroke Patients.

    Science.gov (United States)

    Zhang, Xinmiao; Liao, Xiaoling; Wang, Chunjuan; Liu, Liping; Wang, Chunxue; Zhao, Xingquan; Pan, Yuesong; Wang, Yilong; Wang, Yongjun

    2015-08-01

    The DRAGON score predicts functional outcome of ischemic stroke patients treated with intravenous thrombolysis. Our aim was to evaluate its utility in a Chinese stroke population. Patients with acute ischemic stroke treated with intravenous thrombolysis were prospectively registered in the Thrombolysis Implementation and Monitor of acute ischemic Stroke in China. We excluded patients with basilar artery occlusion and missing data, leaving 970 eligible patients. We calculated the DRAGON score, and the clinical outcome was measured by the modified Rankin Scale at 3 months. Model discrimination was quantified by calculating the C statistic. Calibration was assessed using Pearson correlation coefficient. The C statistic was .73 (.70-.76) for good outcome and .75 (.70-.79) for miserable outcome. Proportions of patients with good outcome were 94%, 83%, 70%, and 0% for 0 to 1, 2, 3, and 8 to 10 score points, respectively. Proportions of patients with miserable outcome were 0%, 3%, 9%, and 50% for 0 to 1, 2, 3, and 8 to 10 points, respectively. There was high correlation between predicted and observed probability of 3-month favorable and miserable outcome in the external validation cohort (Pearson correlation coefficient, .98 and .98, respectively, both P DRAGON score showed good performance to predict functional outcome after tissue-type plasminogen activator treatment in the Chinese population. This study demonstrated the accuracy and usability of the DRAGON score in the Chinese population in daily practice. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  20. External validation of the ability of the DRAGON score to predict outcome after thrombolysis treatment.

    Science.gov (United States)

    Ovesen, C; Christensen, A; Nielsen, J K; Christensen, H

    2013-11-01

    Easy-to-perform and valid assessment scales for the effect of thrombolysis are essential in hyperacute stroke settings. Because of this we performed an external validation of the DRAGON scale proposed by Strbian et al. in a Danish cohort. All patients treated with intravenous recombinant plasminogen activator between 2009 and 2011 were included. Upon admission all patients underwent physical and neurological examination using the National Institutes of Health Stroke Scale along with non-contrast CT scans and CT angiography. Patients were followed up through the Outpatient Clinic and their modified Rankin Scale (mRS) was assessed after 3 months. Three hundred and three patients were included in the analysis. The DRAGON scale proved to have a good discriminative ability for predicting highly unfavourable outcome (mRS 5-6) (area under the curve-receiver operating characteristic [AUC-ROC]: 0.89; 95% confidence interval [CI] 0.81-0.96; pDRAGON scale provided good discriminative capability (AUC-ROC: 0.89; 95% CI 0.78-1.0; p=0.003) for highly unfavourable outcome. We confirmed the validity of the DRAGON scale in predicting outcome after thrombolysis treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Imaging diagnostics of ethanol port fuel injection sprays for automobile engine applications

    International Nuclear Information System (INIS)

    Padala, Srinivas; Le, Minh Khoi; Kook, Sanghoon; Hawkes, Evatt R.

    2013-01-01

    This paper presents characteristics of ethanol sprays at port fuel injection (PFI) conditions with variations in injection and ambient parameters. Details of temporal and spatial development of ethanol PFI sprays are studied using Mie-scattering and high-speed shadowgraph imaging techniques. Momentum flux-based injection rate measurement is also performed. The influences of fuel flow-rate, injection duration, and ambient air cross-flow are of particular interest in an effort to understand ethanol PFI spray characteristics that are relevant to automobile engines. For comparison purposes, the results from gasoline fuel are also presented. Ethanol flow-rate effects are studied using two injectors with different nozzle-hole sizes at a fixed injection pressure. From the experiments, it was found that the actual injection duration was longer for the higher flow-rate injector although an electronic pulse width was fixed. This was due to an extended delay in the injector needle closing as the flow resistance against the needle was increased for the high flow-rate injector. For liquid droplets, the larger hole size of the higher flow-rate injector caused a higher mean droplet diameter and higher number of droplets. Injection duration was also varied to study transient spray behaviour: short-injection sprays with the end-of-injection transient dominating the overall spray development were compared to long, steady-injection sprays. From Mie-scattering images, the number of droplets and mean droplet diameter were found to be less for the short injection sprays. Detailed analysis using an axial profile of the number of droplets and mean droplet diameter suggested that the observed trends were a result of increased evaporation rate near the nozzle after the end of injection. This was consistent with shadowgraph images showing no liquid regions but only the vapour-phase fuel near the nozzle. Under the influence of ambient air cross-flow, both mean droplet diameter and number of

  2. Modifications Of A Commercial Spray Gun

    Science.gov (United States)

    Allen, Peter B.

    1993-01-01

    Commercial spray gun modified to increase spray rate and make sprayed coats more nearly uniform. Consists of gun head and pneumatic actuator. Actuator opens valves for two chemical components, called "A" and "B," that react to produce foam. Components flow through orifices, into mixing chamber in head. Mixture then flows through control orifice to spray tip. New spray tip tapered to reduce area available for accumulation of foam and makes tip easier to clean.

  3. Substrate system for spray forming

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Men G. (Export, PA); Chernicoff, William P. (Harrisburg, PA)

    2002-01-01

    A substrate system for receiving a deposit of sprayed metal droplets including a movable outer substrate on which the sprayed metal droplets are deposited. The substrate system also includes an inner substrate disposed adjacent the outer substrate where the sprayed metal droplets are deposited on the outer substrate. The inner substrate includes zones of differing thermal conductivity to resist substrate layer porosity and to resist formation of large grains and coarse constituent particles in a bulk layer of the metal droplets which have accumulated on the outer substrate. A spray forming apparatus and associated method of spray forming a molten metal to form a metal product using the substrate system of the invention is also provided.

  4. Characterization of Sodium Spray Aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, C. T.; Koontz, R. L.; Silberberg, M. [Atomics International, North American Rockwell Corporation, Canoga Park, CA (United States)

    1968-12-15

    The consequences of pool and spray fires require evaluation in the safety analysis of liquid metal-cooled fast breeder reactors. Sodium spray fires are characterized by high temperature and pressure, produced during the rapid combustion of sodium in air. Following the initial energy release, some fraction of the reaction products are available as aerosols which follow the normal laws of agglomeration, growth, settling, and plating. An experimental study is underway at Atomics International to study the characteristics of high concentration sprays of liquid sodium in reduced oxygen atmospheres and in air. The experiments are conducted in a 31.5 ft{sup 3} (2 ft diam. by 10 ft high) vessel, certified for a pressure of 100 lb/in{sup 2} (gauge). The spray injection apparatus consists of a heated sodium supply pot and a spray nozzle through which liquid sodium is driven by nitrogen pressure. Spray rate and droplet size can be varied by the injection velocity (nozzle size, nitrogen pressure, and sodium temperature). Aerosols produced in 0, 4, and 10 vol. % oxygen environments have been studied. The concentration and particle size distribution of the material remaining in the air after the spray injection and reaction period are measured. Fallout rates are found to be proportional to the concentration of aerosol which remains airborne following the spray period. (author)

  5. A spray flamelet/progress variable approach combined with a transported joint PDF model for turbulent spray flames

    Science.gov (United States)

    Hu, Yong; Olguin, Hernan; Gutheil, Eva

    2017-05-01

    A spray flamelet/progress variable approach is developed for use in spray combustion with partly pre-vaporised liquid fuel, where a laminar spray flamelet library accounts for evaporation within the laminar flame structures. For this purpose, the standard spray flamelet formulation for pure evaporating liquid fuel and oxidiser is extended by a chemical reaction progress variable in both the turbulent spray flame model and the laminar spray flame structures, in order to account for the effect of pre-vaporised liquid fuel for instance through use of a pilot flame. This new approach is combined with a transported joint probability density function (PDF) method for the simulation of a turbulent piloted ethanol/air spray flame, and the extension requires the formulation of a joint three-variate PDF depending on the gas phase mixture fraction, the chemical reaction progress variable, and gas enthalpy. The molecular mixing is modelled with the extended interaction-by-exchange-with-the-mean (IEM) model, where source terms account for spray evaporation and heat exchange due to evaporation as well as the chemical reaction rate for the chemical reaction progress variable. This is the first formulation using a spray flamelet model considering both evaporation and partly pre-vaporised liquid fuel within the laminar spray flamelets. Results with this new formulation show good agreement with the experimental data provided by A.R. Masri, Sydney, Australia. The analysis of the Lagrangian statistics of the gas temperature and the OH mass fraction indicates that partially premixed combustion prevails near the nozzle exit of the spray, whereas further downstream, the non-premixed flame is promoted towards the inner rich-side of the spray jet since the pilot flame heats up the premixed inner spray zone. In summary, the simulation with the new formulation considering the reaction progress variable shows good performance, greatly improving the standard formulation, and it provides new

  6. Abciximab for thrombolysis during intracranial aneurysm coiling

    International Nuclear Information System (INIS)

    Gralla, Jan; Rennie, Adam T.M.; Corkill, Rufus A.; Lalloo, Shivendra T.; Molyneux, Andrew; Byrne, James V.; Kuker, Wilhem

    2008-01-01

    Thrombotic events are a common and severe complication of endovascular aneurysm treatment with significant impact on patients' outcome. This study evaluates risk factors for thrombus formation and assesses the efficacy and safety of abciximab for clot dissolution. All patients treated with abciximab during (41 patients) or shortly after (22 patients) intracranial aneurysm coil embolisation were retrieved from the institutional database (2000 to 2007, 1,250 patients). Sixty-three patients (mean age, 55.3 years, ±12.8) had received either intra-arterial or intravenous abciximab. Risk factors for clot formation were assessed and the angiographic and clinical outcome evaluated. No aneurysm rupture occurred during or after abciximab application. The intra-procedural rate of total recanalisation was 68.3%. Thromboembolic complications were frequently found in aneurysms of the Acom complex and of the basilar artery, whilst internal carotid artery aneurysms were underrepresented. Two patients died of treatment-related intracranial haemorrhages into preexisting cerebral infarcts. Two patients developed a symptomatic groin haematoma. Abciximab is efficacious and safe for thrombolysis during and after endovascular intracranial aneurysm treatment in the absence of preexisting ischaemic stroke. (orig.)

  7. Association of early National Institutes of Health Stroke Scale improvement with vessel recanalization and functional outcome after intravenous thrombolysis in ischemic stroke.

    Science.gov (United States)

    Kharitonova, Tatiana; Mikulik, Robert; Roine, Risto O; Soinne, Lauri; Ahmed, Niaz; Wahlgren, Nils

    2011-06-01

    Early neurological improvement (ENI) after thrombolytic therapy of acute stroke has been linked with recanalization and favorable outcome, although its definition shows considerable variation. We tested the ability of ENI, as defined in previous publications, to predict vessel recanalization and 3-month functional outcome after intravenous thrombolysis recorded in an extensive patient cohort in the Safe Implementation of Thrombolysis in Stroke-International Stroke Thrombolysis Register (SITS-ISTR). Of 21,534 patients registered between December 2002 and December 2008, 798 patients (3.7%) had CT- or MR angiography-documented baseline vessel occlusion and also angiography data at 22 to 36 hours post-treatment. ENI definitions assessed at 2 hours and 24 hours post-treatment were (1) National Institutes of Health Stroke Scale (NIHSS) score improvement ≥4 points from baseline; (2) NIHSS 0, 1, or improvement ≥8; (3) NIHSS ≤3 or improvement ≥10; (4) improvement by 20%; (5) 40% from baseline; or (6) NIHSS score 0 to 1. Receiver operating curve analysis and multiple logistic regression were performed to evaluate the association of ENI with vessel recanalization and favorable functional outcome (modified Rankin Scale score 0 to 2 at 3 months). ENI at 2 hours had fair accuracy to diagnose recanalization as derived from receiver operating curve analysis. Definitions of improvement based on percent of NIHSS score change from baseline demonstrate better accuracy to diagnose recanalization at 2 hours and 24 hours than the definitions based on NIHSS cutoffs (the best performance at 2 hours was area under the curve 0.633, sensitivity 58%, specificity 69%, positive predictive value 68%, and negative predictive value 59% for 20% improvement; and area under the curve 0.692, sensitivity 69%, specificity 70%, positive predictive value 70%, and negative predictive value 62% for 40% improvement at 24 hours). ENI-predicted functional outcome with OR 2.8 to 6.0 independently from

  8. Dynamics of flare sprays

    International Nuclear Information System (INIS)

    Tandberg-Hanssen, E.; Hansen, R.T.

    1980-01-01

    During solar cycle No. 20 new insight into the flare-spray phenomenon has been attained due to several innovations in solar optical-observing techniques (higher spatial resolution cinema-photography, tunable pass-band filters, multi-slit spectroscopy and extended angular field coronographs). From combined analysis of 13 well-observed sprays which occured between 1969-1974 we conclude that (i) the spray material originates from a preexisting active region filament which undergoes increased absorption some tens of minutes prior to the abrupt chromospheric brightening at the 'flare-start', and (ii) the spray material is confined within a steadily expanding, loop-shaped (presumably magnetically controlled) envelope with part of the material draining back down along one or both legs of the loop. (orig.)

  9. Absorption/desorption in sprays

    International Nuclear Information System (INIS)

    Naimpally, A.

    1987-01-01

    This survey paper shall seek to present the present state of knowledge concerning absorption and desorption in spray chambers. The first part of the paper presents the theories and formulas for the atomization and break-up of sprays in nozzles. Formulas for the average (sauter-mean) diameters are then presented. For the case of absorption processes, the formulas for the dimensionless mass transfer coefficients is in drops. The total; mass transfer is the total of the transfer in individual drops. For the case of desorption of sparingly soluble gases from liquids in a spray chamber, the mass transfer occurs in the spray just at the point of break-up of the jet. Formulas for the desorption of gases are presented

  10. Impact of body mass index on outcome in stroke patients treated with intravenous thrombolysis

    OpenAIRE

    Gensicke, H.; Wicht, A.; Bill, O.; Zini, A.; Costa, P.; Kagi, G.; Stark, R.; Seiffge, D. J.; Traenka, C.; Peters, N.; Bonati, L. H.; Giovannini, G.; De Marchis, G. M.; Poli, L.; Polymeris, A.

    2016-01-01

    Abstract: Background and purposeThe impact of body mass index (BMI) on outcome in stroke patients treated with intravenous thrombolysis (IVT) was investigated. MethodsIn a multicentre IVT-register-based observational study, BMI with (i) poor 3-month outcome (i.e. modified Rankin Scale scores 3-6), (ii) death and (iii) symptomatic intracranial haemorrhage (sICH) based on criteria of the ECASS II trial was compared. BMI was used as a continuous and categorical variable distinguishing normal wei...

  11. The programmed nursing care for lower extremity deep venous thrombus patients receiving interventional thrombolysis: its effect on living quality

    International Nuclear Information System (INIS)

    Qiao Cuiyun; Wang Zhujun; Lan Guiyun; Liang Zhiqiang; Shi Yonmin

    2011-01-01

    Objective: Tu study the effect of comprehensive programmed nursing intervention on the living quality in patients with lower extremity deep venous thrombus who receive interventional thrombolysis therapy. Methods: A total of 60 patients receiving interventional thrombolysis due to lower extremity deep venous thrombus were randomly and equally divided into two groups. Patients in study group (n=30) was treated with comprehensive programmed nursing intervention in addition to the conventional therapy and routine nursing care, while patients in control group (n=30) was treated with the conventional therapy and routine nursing care only. The conventional therapy and routine nursing care included the nursing assessment before the operation, observation of the vital signs and the cooperation psychological care during the operation, the performance of medication according to the doctor's orders after the operation, etc. The comprehensive programmed nursing intervention included the nursing assessment of the patient before operation and the scientifically making of the nursing plan, which mainly referred to the cognitive behavior, the psychological care and the health education. They were systematically carried out during the perioperative period. One month after discharge the patients were asked to pay a return visit. The living quality was evaluated with relevant standards, and the results were compared between the two groups. Results: The score of living quality in the study group was significantly higher than that in the control group (P<0.01). Conclusion: The comprehensive programmed nursing intervention can significantly improve the living quality of lower extremity deep venous thrombosis patients who receive interventional thrombolysis therapy. (authors)

  12. Development of spraying methods for high density bentonite barriers. Part 3. Field investigation of spraying methods

    International Nuclear Information System (INIS)

    Tanaka, Toshiyuki; Nakajima, Makoto; Kobayashi, Ichizo; Toida, Masaru; Fukuda, Katsumi; Sato, Tatsuro; Nonaka, Katsumi; Gozu, Keisuke

    2007-01-01

    The authors have developed a new method of constructing high density bentonite barriers by means of a wet spraying method. Using this method, backfill material can be placed in narrow upper and side parts in a low-level radioactive waste disposal facility. Using a new supplying machine for bentonite, spraying tests were conducted to investigate the conditions during construction. On the basis of the test results, the various parameters for the spraying method were investigated. The test results are summarized as follows: 1. The new machine supplied about twice the weight of material supplied by a screw conveyor. A dry density of spraying bentonite 0.05 Mg/m 3 higher than that of a screw conveyor with the same water content could be achieved. 2. The dry density of sprayed bentonite at a boundary with concrete was the same as that at the center of the cross section. 3. The variation in densities of bentonite sprayed in the vertical downward and horizontal directions was small. Also, density reduction due to rebound during spraying was not seen. 4. Bentonite controlled by water content could be sprayed smoothly in the horizontal direction by a small machine. Also rebound could be collected by a machine conveying air. (author)

  13. Thermal response of plasma sprayed tungsten coating to high heat flux

    International Nuclear Information System (INIS)

    Liu, X.; Yang, L.; Tamura, S.; Tokunaga, K.; Yoshida, N.; Noda, N.; Xu, Z.

    2004-01-01

    In order to investigate the thermal response of tungsten coating on carbon and copper substrates by vacuum plasma spray (VPS) or inert gas plasma spray (IPS), annealing and cyclic heat load experiments of these coatings were conducted. It is indicated that the multi-layered tungsten and rhenium interface of VPS-W/CFC failed to act as a diffusion barrier at elevated temperature and tungsten carbides were developed after 1 h incubation time when annealing temperature was higher than 1600 deg. C. IPS-W/Cu and W/C without an intermediate bonding layer were failed by the detachment of the tungsten coating at 900 and 1200 deg. C annealing for several hours, respectively. Cyclic heat load of electron beam with 35 MW/m 2 and 3-s pulse duration indicated that IPS-W/Cu samples failed with local detachment of the tungsten coating within 200 cycles and IPS-W/C showed local cracks by 300 cycles, but VPS-W/CFC withstood 1000 cycles without visible damages. However, crack creation and propagation in VPS-W/CFC were also observed under higher heat load

  14. 1994 Thermal spray industrial applications: Proceedings

    International Nuclear Information System (INIS)

    Berndt, C.C.; Sampath, S.

    1994-01-01

    The 7th National Thermal Spray Conference met on June 20--24, 1994, in Boston, Massachusetts. The conference was sponsored by the Thermal Spray Division of ASM International and co-sponsored by the American Welding Society, Deutscher Verband fur Schweisstechnik e.V., High Temperature Society of Japan, International Thermal Spray Association, and Japanese Thermal Spraying Society. The conference covered applications for automobiles, aerospace, petrochemicals, power generation, and biomedical needs. Materials included metals, ceramics, and composites with a broad range of process developments and diagnostics. Other sections included modeling and systems control; spray forming and reactive spraying; post treatment; process, structure and property relationships; mechanical properties; and testing, characterization and wear. One hundred and seventeen papers have been processed separately for inclusion on the data base

  15. Plasma sprayed samarium--cobalt permanent magnets

    International Nuclear Information System (INIS)

    Willson, M.C.; Janowiecki, R.J.

    1975-01-01

    Samarium--cobalt permanent magnets were fabricated by arc plasma spraying. This process involves the injection of relatively coarse powder particles into a high-temperature gas for melting and spraying onto a substrate. The technique is being investigated as an economical method for fabricating cobalt--rare earth magnets for advanced traveling wave tubes and cross-field amplifiers. Plasma spraying permits deposition of material at high rates over large areas with optional direct bonding to the substrate, and offers the ability to fabricate magnets in a variety of shapes and sizes. Isotropic magnets were produced with high coercivity and good reproducibility in magnetic properties. Post-spray thermal treatments were used to enhance the magnetic properties of sprayed deposits. Samarium--cobalt magnets, sprayed from samarium-rich powder and subjected to post-spray heat treatment, displayed energy products in excess of 9 million gauss-oersteds and coercive forces of approximately 6000 oersteds. Bar magnet arrays were constructed by depositing magnets on ceramic substrates. (auth)

  16. Plasma sprayed samarium--cobalt permanent magnets

    International Nuclear Information System (INIS)

    Willson, M.C.; Janowiecki, R.J.

    1975-01-01

    Samarium--Co permanent magnets were fabricated by arc plasma spraying. This process involves the injection of relatively coarse powder particles into a high temperature gas for melting and spraying onto a substrate. The technique is being investigated as an economical method for fabricating Co--rare earth magnets for advanced traveling wave tubes and cross-field amplifiers. Plasma spraying permits deposition of material at high rates over large areas with optional direct bonding to the substrate, and offers the ability to fabricate magnets in a variety of shapes and sizes. Isotropic magnets were produced with high coercivity and good reproducibility in magnetic properties. Post-spray thermal treatments were used to enhance the magnetic properties of sprayed deposits. Samarium--Co magnets, sprayed from Sm-rich powder and subjected to post-spray heat treatment, displayed energy products in excess of 9 million G-Oe and coercive forces of approximately 6000 Oe. Bar magnet arrays were constructed by depositing magnets on ceramic substrates

  17. Preparation of thermosensitive magnetic liposome encapsulated recombinant tissue plasminogen activator for targeted thrombolysis

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Hao-Lung [Department of Chemical and Materials Engineering, Chang Gung University, Kwei-San, Taoyuan 33302, Taiwan, ROC (China); Chen, Jyh-Ping, E-mail: jpchen@mail.cgu.edu.tw [Department of Chemical and Materials Engineering, Chang Gung University, Kwei-San, Taoyuan 33302, Taiwan, ROC (China); Department of Plastic and Reconstructive Surgery and Craniofacial Research Center, Chang Gung Memorial Hospital, Kwei-San, Taoyuan 33305, Taiwan, ROC (China); Graduate Institute of Health Industry and Technology, Research Center for Industry of Human Ecology, Chang Gung University of Science and Technology, Kwei-San, Taoyuan 33302, Taiwan, ROC (China); Department of Materials Engineering, Ming Chi University of Technology, Tai-Shan, New Taipei City 24301, Taiwan, ROC (China)

    2017-04-01

    Recombinant tissue plasminogen activator (rtPA) was encapsulated in thermosensitive magnetic liposome (TML) prepared from 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, distearolyphosphatidyl ethanolamine-N-poly(ethylene glycol) 2000, cholesterol and Fe{sub 3}O{sub 4} magnetic nanoparticles by solvent evaporation/sonication and freeze-thaw cycles method. Response surface methodology was proved to be a powerful tool to predict the drug encapsulation efficiency and temperature-sensitive drug release. Validation experiments verified the accuracy of the model that provides a simple and effective method for fabricating TML with controllable encapsulation efficiency and predictable temperature-sensitive drug release behavior. The prepared samples were characterized for physico-chemical properties by dynamic light scattering, transmission electron microscopy, X-ray diffraction and differential scanning calorimetry. Temperature-sensitive release of rtPA could be confirmed from in vitro thrombolysis experiments. A thrombolytic drug delivery system using TML could be proposed for magnetic targeted delivery of rtPA to the site of thrombus followed by temperature-triggered controlled drug release in an alternating magnetic field. - Highlights: • rtPA and Fe{sub 3}O{sub 4} MNP were encapsulated in thermosensitive magnetic liposome (TML). • RSM could predict the drug encapsulation efficiency and temperature-sensitive drug release from TML. • Temperature-sensitive release of rtPA was confirmed from in vitro thrombolysis experiments. • TML-rtPA will be useful as a magnetic targeted nanodrug to improve clinical thrombolytic therapy.

  18. Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol

    Science.gov (United States)

    2010-07-01

    Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model

  19. Effects of spray axis incident angle on heat transfer performance of rhombus-pitch shell-and-tube interior spray evaporator

    International Nuclear Information System (INIS)

    Lin, Ru-Li; Chang, Tong-Bou; Liang, Chih-Chang

    2012-01-01

    An interior spray method is proposed for enhancing the heat transfer performance of a compact rhombus-pitch shell-and-tube spray evaporator. The experimental results show that the shell-side heat transfer coefficient obtained using the proposed spray method is significantly higher than that achieved in a conventional flooded-type evaporator. Four different spray axis incident angles (0 .deg., 45 .deg., 60 .deg. and 75 .deg.) are tested in order to investigate the effect of the spray inclination angle on the heat transfer performance of the spray evaporator system. It is shown that the optimal heat transfer performance is obtained using a spray axis incident angle of 60 .deg.

  20. A study on the macroscopic spray behavior and atomization characteristics of biodiesel and dimethyl ether sprays under increased ambient pressure

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Jun; Park, Su Han [Graduate School of Hanyang University, 17 Haengdang-dong, Seoungdong-gu, Seoul 133-791 (Korea); Lee, Chang Sik [Department of Mechanical Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea)

    2010-03-15

    The aim of this work is to investigate the spray behaviors of biodiesel and dimethyl ether (DME) fuels using image processing and atomization performance analysis of the two fuel sprays injected through a common-rail injection system under various ambient pressure conditions in a high pressure chamber. In order to observe the biodiesel and DME fuel spray behaviors under various ambient pressures, the spray images were analyzed at various times after the start of energization using a visualization system consisting of a high speed camera and two metal halide light sources. In addition, a high pressure chamber that can withstand a pressure of 4 MPa was used for adjusting the ambient pressure. From the spray images, spray characteristics such as the spray tip penetration, cone angle, area, and contour plot at various light intensity levels were analyzed using image conversion processing. Also, the local Sauter mean diameters (SMD) were measured at various axial/radial distances from the nozzle tip by a droplet measuring system to compare the atomization performances of the biodiesel and DME sprays. The results showed that the ambient pressure had a significant effect on the spray characteristics of the fuels at the various experimental conditions. The spray tip penetration and spray area decreased as the ambient pressure increased. The contour plot of the biodiesel and DME sprays showed a high light intensity level in the center regions of the sprays. In addition, it was revealed that the atomization performance of the biodiesel spray was inferior to that of the DME spray at the same injection and ambient conditions. (author)

  1. Prehospital thrombolysis in acute myocardial infarction: the Belgian eminase prehospital study (BEPS). BEPS Collaborative Group.

    Science.gov (United States)

    1991-09-01

    Interest in early thrombolysis has prompted a study on the feasibility and time course of prehospital thrombolysis in patients with acute myocardial infarction (AMI) in six centres in Belgium. Patients with clinically suspected AMI and with typical ECG changes presenting within 4 h after onset of pain were treated with 30 units of Anisoylated Plasminogen Streptokinase Activator Complex (APSAC, eminase) intravenously by a mobile intensive care unit (MICU). Sixty-two patients were included in the study and an AMI was confirmed in 60. The mean time (+/- 1 SD) from onset of pain to injection of APSAC was 95 +/- 47 min and the mean estimated time gain, calculated as the time difference between the arrival of the MICU at home and the arrival of the MICU at the emergency department, was 50 +/- 17 min. In the prehospital period four patients developed ventricular fibrillation and one cardiogenic shock. During hospital stay severe complications were observed in four patients. Two events were fatal, one diffuse haemorrhage and one septal rupture; two events were non fatal, one feasible and that an estimated time gain of 50 min can be obtained. Potential risks and benefits remain to be demonstrated in a large controlled clinical trial.

  2. Fixed automated spray technology.

    Science.gov (United States)

    2011-04-19

    This research project evaluated the construction and performance of Boschungs Fixed Automated : Spray Technology (FAST) system. The FAST system automatically sprays de-icing material on : the bridge when icing conditions are about to occur. The FA...

  3. LSPRAY-IV: A Lagrangian Spray Module

    Science.gov (United States)

    Raju, M. S.

    2012-01-01

    LSPRAY-IV is a Lagrangian spray solver developed for application with parallel computing and unstructured grids. It is designed to be massively parallel and could easily be coupled with any existing gas-phase flow and/or Monte Carlo Probability Density Function (PDF) solvers. The solver accommodates the use of an unstructured mesh with mixed elements of either triangular, quadrilateral, and/or tetrahedral type for the gas flow grid representation. It is mainly designed to predict the flow, thermal and transport properties of a rapidly vaporizing spray. Some important research areas covered as a part of the code development are: (1) the extension of combined CFD/scalar-Monte- Carlo-PDF method to spray modeling, (2) the multi-component liquid spray modeling, and (3) the assessment of various atomization models used in spray calculations. The current version contains the extension to the modeling of superheated sprays. The manual provides the user with an understanding of various models involved in the spray formulation, its code structure and solution algorithm, and various other issues related to parallelization and its coupling with other solvers.

  4. Droplets and sprays

    CERN Document Server

    Sazhin, Sergei

    2014-01-01

    Providing a clear and systematic description of droplets and spray dynamic models, this book maximises reader insight into the underlying physics of the processes involved, outlines the development of new physical and mathematical models, and broadens understanding of interactions between the complex physical processes which take place in sprays. Complementing approaches based on the direct application of computational fluid dynamics (CFD), Droplets and Sprays treats both theoretical and practical aspects of internal combustion engine process such as the direct injection of liquid fuel, subcritical heating and evaporation. Includes case studies that illustrate the approaches relevance to automotive applications,  it is also anticipated that the described models can find use in other areas such as in medicine and environmental science.

  5. COUPLED ATOMIZATION AND SPRAY MODELLING IN THE SPRAY FORMING PROCESS USING OPENFOAM

    DEFF Research Database (Denmark)

    Gjesing, Rasmus; Hattel, Jesper Henri; Fritsching, Udo

    2009-01-01

    The paper presents a numerical model capable of simulating the atomization, break-up and in-flight spray phenomena in the spray forming process. The model is developed and implemented in the freeware code openFOAM. The focus is on studying the coupling effect of the melt break-up phenomena...

  6. Catheter-Directed Thrombolysis of Deep Vein Thrombosis in a Patient with Churg-Strauss Syndrome: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Beom; Kim, See Hyung; Choi, Jin Soo; Kim, Young Hwan [Dongsan Hospital, Keimyung University, Daegu (Korea, Republic of)

    2010-10-15

    Vasculitis by Churg-Strauss Syndrome (CSS) is an uncommon disease characterized by the inflammation of blood vessel walls and can involve many organs. The clinical manifestations and courses of vasculitis are highly variable. Deep vein thrombosis has rarely been reported in vasculitis by CSS. We report a case of deep vein thrombosis associated with CSS that was successfully treated by catheter-directed thrombolysis.

  7. Catheter-Directed Thrombolysis of Deep Vein Thrombosis in a Patient with Churg-Strauss Syndrome: A Case Report

    International Nuclear Information System (INIS)

    Park, Jun Beom; Kim, See Hyung; Choi, Jin Soo; Kim, Young Hwan

    2010-01-01

    Vasculitis by Churg-Strauss Syndrome (CSS) is an uncommon disease characterized by the inflammation of blood vessel walls and can involve many organs. The clinical manifestations and courses of vasculitis are highly variable. Deep vein thrombosis has rarely been reported in vasculitis by CSS. We report a case of deep vein thrombosis associated with CSS that was successfully treated by catheter-directed thrombolysis

  8. A Score for Risk of Thrombolysis-Associated Hemorrhage Including Pretreatment with Statins

    Directory of Open Access Journals (Sweden)

    Hebun Erdur

    2018-02-01

    Full Text Available BackgroundSymptomatic intracranial hemorrhage (sICH after intravenous thrombolysis with recombinant tissue-plasminogen activator (rt-PA for acute ischemic stroke is associated with a poor functional outcome. We aimed to develop a score assessing risk of sICH including novel putative predictors—namely, pretreatment with statins and severe renal impairment.MethodsWe analyzed our local cohort (Berlin of patients receiving rt-PA for acute ischemic stroke between 2006 and 2016. Outcome was sICH according to ECASS-III criteria. A multiple regression model identified variables associated with sICH and receiver operating characteristics were calculated for the best discriminatory model for sICH. The model was validated in an independent thrombolysis cohort (Basel.ResultssICH occurred in 53 (4.0% of 1,336 patients in the derivation cohort. Age, baseline National Institutes of Health Stroke Scale, systolic blood pressure on admission, blood glucose on admission, and prior medication with medium- or high-dose statins were associated with sICH and included into the risk of intracranial hemorrhage score. The validation cohort included 983 patients of whom 33 (3.4% had a sICH. c-Statistics for sICH was 0.72 (95% CI 0.66–0.79 in the derivation cohort and 0.69 (95% CI 0.60–0.77 in the independent validation cohort. Inclusion of severe renal impairment did not improve the score.ConclusionWe developed a simple score with fair discriminating capability to predict rt-PA-related sICH by adding prior statin use to known prognostic factors of sICH. This score may help clinicians to identify patients with higher risk of sICH requiring intensive monitoring.

  9. Diesel spray characterization; Dieselmoottorin polttoainesuihkujen ominaisuudet

    Energy Technology Data Exchange (ETDEWEB)

    Pitkaenen, J.; Turunen, R.; Paloposki, T.; Rantanen, P.; Virolainen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Internal Combustion Engine Lab.

    1997-10-01

    Fuel injection of diesel engines will be studied using large-scale models of fuel injectors. The advantage of large-scale models is that the measurement of large-scale diesel sprays will be easier than the measurement of actual sprays. The objective is to study the break-up mechanism of diesel sprays and to measure drop size distributions in the inner part of the spray. The results will be used in the development of diesel engines and diesel fuels. (orig.)

  10. Head spray nozzle in reactor pressure vessel

    International Nuclear Information System (INIS)

    Hatano, Shun-ichi.

    1990-01-01

    In a reactor pressure vessel of a BWR type reactor, a head spray nozzle is used for cooling the head of the pressure vessel and, in view of the thermal stresses, it is desirable that cooling is applied as uniformly as possible. A conventional head spray is constituted by combining full cone type nozzles. Since the sprayed water is flown down upon water spraying and the sprayed water in the vertical direction is overlapped, the flow rate distribution has a high sharpness to form a shape as having a maximum value near the center and it is difficult to obtain a uniform flow rate distribution in the circumferential direction. Then, in the present invention, flat nozzles each having a spray water cross section of laterally long shape, having less sharpness in the circumferential distribution upon spraying water to the inner wall of the pressure vessel and having a wide angle of water spray are combined, to make the flow rate distribution of spray water uniform in the inner wall of the pressure vessel. Accordingly, the pressure vessel can be cooled uniformly and thermal stresses upon cooling can be decreased. (N.H.)

  11. Multiple-Nozzle Spray Head Applies Foam Insulation

    Science.gov (United States)

    Walls, Joe T.

    1993-01-01

    Spray head equipped with four-nozzle turret mixes two reactive components of polyurethane and polyisocyanurate foam insulating material and sprays reacting mixture onto surface to be insulated. If nozzle in use becomes clogged, fresh one automatically rotated into position, with minimal interruption of spraying process. Incorporates features recirculating and controlling pressures of reactive components to maintain quality of foam by ensuring proper blend at outset. Also used to spray protective coats on or in ships, aircraft, and pipelines. Sprays such reactive adhesives as epoxy/polyurethane mixtures. Components of spray contain solid-particle fillers for strength, fire retardance, toughness, resistance to abrasion, or radar absorption.

  12. Water spray interaction with air-steam mixtures under containment spray conditions: experimental study in the TOSQAN facility

    Energy Technology Data Exchange (ETDEWEB)

    Porcheron, E.; Lemaitre, P.; Malet, J.; Nuboer, A.; Brun, P.; Bouilloux, L.; Vendel, J. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Direction de la Surete des Usines, des laboratoires, des transports et des dechets, Saclay, BP 68 - 91192 Gif-sur-Yvette cedex (France)

    2005-07-01

    Full text of publication follows: During the course of an hypothetical severe accident in a Pressurized Water Reactor (PWR), hydrogen can be produced by the reactor core oxidation and distributed into the reactor containment according to convection flows and steam wall condensation. In order to assess the risk of detonation generated by a high local hydrogen concentration, hydrogen distribution in the containment has to be known. The TOSQAN experimental program has been created to simulate typical accidental thermal hydraulic flow conditions in the reactor containment. The present work is devoted to study the interaction of a water spray injection used as a mitigation mean in order to reduce containment pressure and to produce a mixing of air, steam and hydrogen induced by spray entrainment and condensation on droplet. In order to have a better understanding of physical phenomena, we need to make a detailed characterization of the spray and the gas. The TOSQAN facility that is highly instrumented with non-intrusive diagnostics consists in a closed cylindrical vessel (7 m{sup 3} volume, 4 m high, 1.5 m i.d.) into which steam is injected. Water droplets size is measured in the vessel by the Interferometric Laser Imaging for Droplet Sizing technique. Droplet velocity is obtained by Particle Image Velocimetry and Laser Doppler Velocimetry, and droplet temperature is measured by global rainbow refractometry. Gas concentration measurements are performed by Spontaneous Raman Scattering. The walls of the vessel are thermostatically controlled by heated oil circulation. Inner spray system that is located on the top of the enclosure on the vertical axis, is composed of a single nozzle producing a full cone water spray. Spray test scenario consists of water spray injection in TOSQAN that is first pressurized with a steam injection (steam injection is stopped before spray injection). Water spray falling into the sump is removed to avoid accumulation and evaporation

  13. Gas entrainment by one single French PWR spray, SARNET-2 spray benchmark

    Energy Technology Data Exchange (ETDEWEB)

    Malet, J., E-mail: jeanne.malet@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire, Saclay (France); Mimouni, S., E-mail: stephane.mimouni@edf.fr [Electricité de France, EDF MF2E, Chatou (France); Manzini, G., E-mail: giovanni.manzini@rse-web.it [RSE, Milano (Italy); Xiao, J., E-mail: jianjun.xiao@kit.edu [IKET, KIT, Karlsruhe (Germany); Vyskocil, L., E-mail: vyl@ujv.cz [UJV Rez (Czech Republic); Siccama, N.B., E-mail: siccama@nrg.eu [NRG, Safety and Power (Netherlands); Huhtanen, R., E-mail: risto.huhtanen@vtt.fi [VTT, PO Box 1000, FI-02044 VTT (Finland)

    2015-02-15

    Highlights: • This paper presents a benchmark performed in the frame of the SARNET-2 EU project. • It concerns momentum transfer between a PWR spray and the surrounding gas. • The entrained gas velocities can vary up to 100% from one code to another. • Simplified boundary conditions for sprays are generally used by the code users. • It is shown how these simplified conditions impact the gas entrainment. - Abstract: This paper presents a benchmark performed in the frame of the SARNET-2 EU project, dealing with momentum transfer between a real-scale PWR spray and the surrounding gas. It presents a description of the IRSN tests on the CALIST facility, the participating codes (8 contributions), code-experiment and code-to-code comparisons. It is found that droplet velocities are almost well calculated one meter below the spray nozzle, even if the spread of the spray is not recovered and the values of the entrained gas velocity vary up to 100% from one code to another. Concerning sensitivity analysis, several ‘simplifications’ have been made by the contributors, especially based on the boundary conditions applied at the location where droplets are injected. It is shown here that such simplifications influence droplet and entrained gas characteristics. The next step will be to translate these conclusions in terms of variables representative of interesting parameters for nuclear safety.

  14. Gas entrainment by one single French PWR spray, SARNET-2 spray benchmark

    International Nuclear Information System (INIS)

    Malet, J.; Mimouni, S.; Manzini, G.; Xiao, J.; Vyskocil, L.; Siccama, N.B.; Huhtanen, R.

    2015-01-01

    Highlights: • This paper presents a benchmark performed in the frame of the SARNET-2 EU project. • It concerns momentum transfer between a PWR spray and the surrounding gas. • The entrained gas velocities can vary up to 100% from one code to another. • Simplified boundary conditions for sprays are generally used by the code users. • It is shown how these simplified conditions impact the gas entrainment. - Abstract: This paper presents a benchmark performed in the frame of the SARNET-2 EU project, dealing with momentum transfer between a real-scale PWR spray and the surrounding gas. It presents a description of the IRSN tests on the CALIST facility, the participating codes (8 contributions), code-experiment and code-to-code comparisons. It is found that droplet velocities are almost well calculated one meter below the spray nozzle, even if the spread of the spray is not recovered and the values of the entrained gas velocity vary up to 100% from one code to another. Concerning sensitivity analysis, several ‘simplifications’ have been made by the contributors, especially based on the boundary conditions applied at the location where droplets are injected. It is shown here that such simplifications influence droplet and entrained gas characteristics. The next step will be to translate these conclusions in terms of variables representative of interesting parameters for nuclear safety

  15. 14 CFR 23.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 23.239 Section 23.239 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... Handling Characteristics § 23.239 Spray characteristics. Spray may not dangerously obscure the vision of...

  16. 14 CFR 29.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 29.239 Section 29... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Flight Ground and Water Handling Characteristics § 29.239 Spray characteristics. If certification for water operation is requested, no spray characteristics...

  17. 14 CFR 27.239 - Spray characteristics.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Spray characteristics. 27.239 Section 27... AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Flight Ground and Water Handling Characteristics § 27.239 Spray characteristics. If certification for water operation is requested, no spray characteristics...

  18. A comparison of biological effect and spray liquid distribution and deposition for different spray application techniques in different crops

    OpenAIRE

    Larsolle, Anders; Wretblad, Per; Westberg, Carl

    2002-01-01

    The objective of this study was to compare a selection of spray application techniques with different application volumes, with respect to the spray liquid distribution on flat surfaces, the deposition in fully developed crops and the biological effect. The spray application techniques in this study were conventional spray technique with three different nozzles: Teelet XR, Lechler ID and Lurmark DriftBeta, and also AirTec, Danfoil, Hardi Twin, Kyndestoit and Släpduk. The dynamic spray liquid ...

  19. Transient analysis of intermittent multijet sprays

    Energy Technology Data Exchange (ETDEWEB)

    Panao, Miguel R.O.; Moreira, Antonio Luis N. [Universidade Tecnica de Lisboa, IN, Center for Innovation, Technology and Policy Research, Instituto Superior Tecnico, Lisboa (Portugal); Durao, Diamantino G. [Universidade Lusiada, Lisboa (Portugal)

    2012-07-15

    This paper analyzes the transient characteristics of intermittent sprays produced by the single-point impact of multiple cylindrical jets. The aim is to perform a transient analysis of the intermittent atomization process to study the effect of varying the number of impinging jets in the hydrodynamic mechanisms of droplet formation. The results evidence that hydrodynamic mechanisms underlying the physics of ligament fragmentation in 2-impinging jets sprays also apply to sprays produced with more than 2 jets during the main period of injection. Ligaments detaching from the liquid sheet, as well as from its bounding rim, have been identified and associated with distinct droplet clusters, which become more evident as the number of impinging jets increases. Droplets produced by detached ligaments constitute the main spray, and their axial velocity becomes more uniformly distributed with 4-impinging jets because of a delayed ligament fragmentation. Multijet spray dispersion patterns are geometric depending on the number of impinging jets. Finally, an analysis on the Weber number of droplets suggests that multijet sprays are more likely to deposit on interposed surfaces, thus becoming a promising and competitive atomization solution for improving spray cooling. (orig.)

  20. Successful Intra-Arterial Thrombolysis for Acute Ischemic Stroke in the Immediate Postpartum Period: Case Report

    International Nuclear Information System (INIS)

    Mendez, Jose C.; Masjuan, J.; Garcia, N.; Lecinana, M. de

    2008-01-01

    Stroke in pregnancy and the puerperium is a rare but potentially devastating event. We present the case of a previously healthy woman who underwent a cesarean delivery and experienced a middle cerebral artery thrombosis in the immediate postpartum period that was subsequently lysed with intra-arterial urokinase. The patient made a complete neurologic recovery. To the best of our knowledge, this is the first reported case of successful intra-arterial thrombolysis for ischemic stroke in the postpartum period

  1. Renal Infarction Caused by Spontaneous Renal Artery Dissection: Treatment with Catheter-Directed Thrombolysis and Stenting

    International Nuclear Information System (INIS)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Ki Cheon

    2009-01-01

    Spontaneous renal artery dissection (SRAD) is rare and presents a diagnostic and therapeutic challenge. We report a case of a 36-year-old man who had an SRAD-complicated renal infarction. The patient experienced severe unilateral flank pain. Enhanced abdominal computed axial tomography scan showed renal infarction, and urinalysis showed no hematuria. Selective renal angiography was essential to evaluate the extent of dissection and suitability for repair. The patient was treated with catheter-directed thrombolysis and frenal artery stenting.

  2. Effectiveness of containment sprays in containment management

    International Nuclear Information System (INIS)

    Nourbakhsh, H.P.; Perez, S.E.; Lehner, J.R.

    1993-05-01

    A limited study has been performed assessing the effectiveness of containment sprays-to mitigate particular challenges which may occur during a severe accident. Certain aspects of three specific topics related to using sprays under severe accident conditions were investigated. The first was the effectiveness of sprays connected to an alternate water supple and pumping source because the actual containment spray pumps are inoperable. This situation could occur during a station blackout. The second topic concerned the adverse as well as beneficial effects of using containment sprays during severe accident scenario where the containment atmosphere contains substantial quantities of hydrogen along with steam. The third topic was the feasibility of using containment sprays to moderate the consequences of DCH

  3. Preparation of cellulose based microspheres by combining spray coagulating with spray drying.

    Science.gov (United States)

    Wang, Qiao; Fu, Aiping; Li, Hongliang; Liu, Jingquan; Guo, Peizhi; Zhao, Xiu Song; Xia, Lin Hua

    2014-10-13

    Porous microspheres of regenerated cellulose with size in range of 1-2 μm and composite microspheres of chitosan coated cellulose with size of 1-3 μm were obtained through a two-step spray-assisted approach. The spray coagulating process must combine with a spray drying step to guarantee the formation of stable microspheres of cellulose. This approach exhibits the following two main virtues. First, the preparation was performed using aqueous solution of cellulose as precursor in the absence of organic solvent and surfactant; Second, neither crosslinking agent nor separated crosslinking process was required for formation of stable microspheres. Moreover, the spray drying step also provided us with the chance to encapsulate guests into the resultant cellulose microspheres. The potential application of the cellulose microspheres acting as drug delivery vector has been studied in two PBS (phosphate-buffered saline) solution with pH values at 4.0 and 7.4 to mimic the environments of stomach and intestine, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Effect of alteplase thrombolysis sequenced by low molecular heparin calcium antithrombosis on the neurological function and serum cytokines in patients with cerebral infarction

    Directory of Open Access Journals (Sweden)

    Yi-Ping Dan

    2017-04-01

    Full Text Available Objective: To study the effect of alteplase thrombolysis sequenced by low molecular heparin calcium antithrombosis on the neurological function and serum cytokines in patients with cerebral infarction. Methods: Patients with acute cerebral infarction who received alteplase thrombolysis in Zigong Fourth People's Hospital between June 2014 and October 2016 were retrospectively analyzed and divided into the intervention group who received low molecular heparin calcium treatment and the control group who did not receive low molecular heparin calcium treatment. The serum was collected before and after treatment to determine the contents of platelet activation factors, nerve injury molecules, soluble apoptotic molecules and growth factors. Results: Serum CD62p, CD63, PAF, GMP-140, NSE, S100B, GFAP, sFas, sFasL, sTRAIL, IGF-1, VEGF, BDNF and bFGF levels of both groups of patients after treatment were lower than those before treatment, serum CD62p, CD63, PAF, GMP-140, NSE, S100B, GFAP, sFas, sFasL and sTRAIL levels of intervention group after treatment were lower than those of control group while IGF-1, VEGF, BDNF and bFGF levels were higher than those of control group. Conclusion: Alteplase thrombolysis sequenced by low molecular heparin calcium antithrombosis for acute cerebral infarction can inhibit platelet activation and cell apoptosis, alleviate nerve injury and improve neurotrophy status.

  5. An evaluation of the electric arc spray and (HPPS) processes for the manufacturing of high power plasma spraying MCrAIY coatings

    Science.gov (United States)

    Sacriste, D.; Goubot, N.; Dhers, J.; Ducos, M.; Vardelle, A.

    2001-06-01

    The high power plasma torch (PlazJet) can be used to spray refractory ceramics with high spray rates and deposition efficiency. It can provide dense and hard coating with high bond strengths. When manufacturing thermal barrier coatings, the PlazJet gun is well adapted to spraying the ceramic top coat but not the MCrAIY materials that are used as bond coat. Arc spraying can compete with plasma spraying for metallic coatings since cored wires can be used to spray alloys and composites. In addition, the high production rate of arc spraying enables a significant decrease in coating cost. This paper discusses the performances of the PlazJet gun, and a twin-wire are spray system, and compares the properties and cost of MCrAIY coatings made with these two processes. For arc spraying, the use of air or nitrogen as atomizing gas is also investigated.

  6. ROTARY SPRAY DUSTER

    Directory of Open Access Journals (Sweden)

    E. S. Nechaeva

    2013-01-01

    Full Text Available Results of researches of hydraulic resistance, ablation of splashes and efficiency of dedusting in the rotor spray dust collector are given. Influence of frequency of rotation of the spray, the specified speed of gas and diameter of spattering holes on hydraulic resistance, size ablation of splashes and efficiency of a dedusting the device by diameter 0,25 m is investigated. As model liquid water is used. Results of mathematical processing are presented.

  7. On the modeling of fuel sprays

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Christer

    1997-12-01

    This report concerns on the modelling of fuel sprays in a non-combustible case using an own developed fuel spray code module. The spray code is made as an independent module to simplify the use of different gas flow solvers together with the spray module. This enables the possibility to use different turbulence models. In the report two turbulence models has been used, the standard k-{epsilon} and the LES (Large Eddy Simulation) model. The report presents results obtained from a sensitivity study of both numerical and physical parameters on an evaporating spray under diesel like conditions (light duty diesel engine) with the spray code module attached to a cylindrical gas phase flow solver. The results from the sensitivity analysis showed that these effects were not so pronounced as has been reported. It was suggested that this was due to the `easy` nature of the investigated case, where the flow field could be sufficiently resolved without violating the droplet void fraction criteria and break-up, collision and combustion that may increase the grid spacing sensitivity were not modelled. An investigation was performed to valuate the feasibility of using LES as turbulence model. Calculations of the initial phase of a developing jet were made and it was found that in the initial phase of the spray and the flow structure were similar to that of a spatially developing jet flow, which is in agreement with experimental observations. Results from LES calculations on a developing spray jet was also compared with k-{epsilon} based ones. This result showed that the spray-LES approach captured the transition from a laminar to a turbulent flow field with an increase in turbulent kinetic energy k along the injection direction 45 refs, 37 figs, 2 tabs

  8. Radio-frequency plasma spraying of ceramics

    International Nuclear Information System (INIS)

    Okada, T.; Hamatani, H.; Yoshida, T.

    1989-01-01

    This study was aimed at developing a novel spraying process using a radio-frequency (rf) plasma. Experiments of Al 2 O 3 and ZrO 2 - 8 wt% Y 2 O 3 spraying showed that the initial powder size was the most important parameter for depositing dense coatings. The optimum powder sizes of Al 2 O 3 and ZrO 2 - 8 wt% Y 2 O 3 were considered to be around 100 and 80 μm, respectively. The use of such large-size powders compared with those used by conventional dc plasma spraying made it possible to deposit adherent ceramics coatings of 150 to 300 μm on as-rolled SS304 substrates. It was also shown that low particle velocity of about 10 m/s, which is peculiar to rf plasma spraying, was sufficient for particle deformation, though it imposed a severe limitation on the substrate position. These experimental results prove that rf plasma spraying is an effective process and a strong candidate to open new fields of spraying applications

  9. Direct morphological comparison of vacuum plasma sprayed and detonation gun sprayed hydroxyapatite coatings for orthopaedic applications.

    Science.gov (United States)

    Gledhill, H C; Turner, I G; Doyle, C

    1999-02-01

    Hydroxyapatite coatings on titanium substrates were produced using two thermal spray techniques vacuum plasma spraying and detonation gun spraying. X-ray diffraction was used to compare crystallinity and residual stresses in the coatings. Porosity was measured using optical microscopy in conjunction with an image analysis system. Scanning electron microscopy and surface roughness measurements were used to characterise the surface morphologies of the coatings. The vacuum plasma sprayed coatings were found to have a lower residual stress, a higher crystallinity and a higher level of porosity than the detonation gun coatings. It is concluded that consideration needs to be given to the significance of such variations within the clinical context.

  10. Large Eddy Simulation of the spray formation in confinements

    International Nuclear Information System (INIS)

    Lampa, A.; Fritsching, U.

    2013-01-01

    Highlights: • Process stability of confined spray processes is affected by the geometric design of the spray confinement. • LES simulations of confined spray flow have been performed successfully. • Clustering processes of droplets is predicted in simulations and validated with experiments. • Criteria for specific coherent gas flow patterns and droplet clustering behaviour are found. -- Abstract: The particle and powder properties produced within spray drying processes are influenced by various unsteady transport phenomena in the dispersed multiphase spray flow in a confined spray chamber. In this context differently scaled spray structures in a confined spray environment have been analyzed in experiments and numerical simulations. The experimental investigations have been carried out with Particle-Image-Velocimetry to determine the velocity of the gas and the discrete phase. Large-Eddy-Simulations have been set up to predict the transient behaviour of the spray process and have given more insight into the sensitivity of the spray flow structures in dependency from the spray chamber design

  11. Experimental characterization of gasoline sprays under highly evaporating conditions

    Science.gov (United States)

    Khan, Muhammad Mahabat; Sheikh, Nadeem Ahmed; Khalid, Azfar; Lughmani, Waqas Akbar

    2018-05-01

    An experimental investigation of multistream gasoline sprays under highly evaporating conditions is carried out in this paper. Temperature increase of fuel and low engine pressure could lead to flash boiling. The spray shape is normally modified significantly under flash boiling conditions. The spray plumes expansion along with reduction in the axial momentum causes the jets to merge and creates a low-pressure area below the injector's nozzle. These effects initiate the collapse of spray cone and lead to the formation of a single jet plume or a big cluster like structure. The collapsing sprays reduces exposed surface and therefore they last longer and subsequently penetrate more. Spray plume momentum increase, jet plume reduction and spray target widening could delay or prevent the closure condition and limit the penetration (delayed formation of the cluster promotes evaporation). These spray characteristics are investigated experimentally using shadowgraphy, for five and six hole injectors, under various boundary conditions. Six hole injectors produce more collapsing sprays in comparison to five hole injector due to enhanced jet to jet interactions. The spray collapse tendency reduces with increase in injection pressure due high axial momentum of spray plumes. The spray evaporation rates of five hole injector are observed to be higher than six hole injectors. Larger spray cone angles of the six hole injectors promote less penetrating and less collapsing sprays.

  12. Cold spray nozzle design

    Science.gov (United States)

    Haynes, Jeffrey D [Stuart, FL; Sanders, Stuart A [Palm Beach Gardens, FL

    2009-06-09

    A nozzle for use in a cold spray technique is described. The nozzle has a passageway for spraying a powder material, the passageway having a converging section and a diverging section, and at least the diverging section being formed from polybenzimidazole. In one embodiment of the nozzle, the converging section is also formed from polybenzimidazole.

  13. Catheter-directed thrombolysis for acute iliofemoral deep vein thrombosis via the ipsilateral great saphenous vein approach: a comparative clinical study

    International Nuclear Information System (INIS)

    Su Haobo; Gu Jianping; Lou Wensheng; He Xu; Chen Liang; Chen Guoping; Song Jinhua; Wang Tao

    2011-01-01

    Objective: To investigate prospectively the feasibility and clinical value of catheterization via the ipsilateral great saphenous vein in catheter-directed thrombolysis (CDT) for acute iliofemoral deep vein thrombosis (IFVT) by a comparative study. Methods: The prospective study included 93 cases of IFVT proved by venography. All patients were divided into three groups randomly. In group A, 31 patients received CDT via the ipsilateral great saphenous vein. In group B, 27 patients received CDT via the ipsilateral popliteal vein. In group C, 35 patients received anterograde thrombolysis via an ipsilateral dorsalis pedis vein. Urokinase was adopted as the thrombolytic agent in all cases. The assessment of the curative effect include therapeutic effective rate, rate of edema reduction and venous patency which were observed according to the clinical symptoms and the follow-up venograms obtained 5 days after thrombolysis. The time and comfort scores of procedures was recorded and compared between group A and B using two independent samples t test. The rate of edema reduction and venous patency were assessed using analysis of variance (LSD method). Therapeutic effective rate and complication rate were assessed using Chi-square test. Results: The total effective rate of the three groups were 90.3% (28/31), 92.6% (25/27) and 68.6% (24/35) respectively. The limbs edema reduction rate were (83.5±21.1)%, (82.4±20.1)%, and (67.0±23.3)% respectively (F= 6.059, P=0.003). The venous patency rate after thrombolysis were (61.2±20.2)%, (55.7±20.5)%, and (44.2±23.6)% respectively. There was no significant difference between group A and B in therapeutic effective rate (χ 2 =0.09, P=0.759), rate of edema reduction (P=0.822) and venous patency (P=0.343) . There was a significant difference statistically in therapeutic effective rate (χ 2 =4.65, P=0.031), rate of edema reduction (P=0.002) and venous patency (P=0.002) between group A and C. Compared with group A and B, the

  14. Study of Multi-Function Micro-Plasma Spraying Technology

    International Nuclear Information System (INIS)

    Wang Liuying; Wang Hangong; Hua Shaochun; Cao Xiaoping

    2007-01-01

    A multi-functional micro-arc plasma spraying system was developed according to aerodynamics and plasma spray theory. The soft switch IGBT (Insulated Gate Bipolar Transistor) invert technique, micro-computer control technique, convergent-divergent nozzle structure and axial powder feeding techniques have been adopted in the design of the micro-arc plasma spraying system. It is not only characterized by a small volume, a light weight, highly accurate control, high deposition efficiency and high reliability, but also has multi-functions in plasma spraying, welding and quenching. The experimental results showed that the system can produce a supersonic flame at a low power, spray Al 2 O 3 particles at an average speed up to 430 m/s, and make nanostructured AT13 coatings with an average bonding strength of 42.7 MPa. Compared to conventional 9M plasma spraying with a higher power, the coatings with almost the same properties as those by conventional plasma spray can be deposited by multi-functional micro-arc plasma spraying with a lower power plasma arc due to an improved power supply design, spray gun structure and powder feeding method. Moreover, this system is suitable for working with thin parts and undertaking on site repairs, and as a result, the application of plasma spraying will be greatly extended

  15. Study on Spray Characteristics and Spray Droplets Dynamic Behavior of Diesel Engine Fueled by Rapeseed Oil

    Directory of Open Access Journals (Sweden)

    Sapit Azwan

    2014-07-01

    Full Text Available Fuel-air mixing is important process in diesel combustion. It directly affects the combustion and emission of diesel engine. Biomass fuel needs great help to atomize because the fuel has high viscosity and high distillation temperature. This study investigates the atomization characteristics and droplet dynamic behaviors of diesel engine spray fueled by rapeseed oil (RO. Optical observation of RO spray was carried out using shadowgraph photography technique. Single nano-spark photography technique was used to study the characteristics of the rapeseed oil spray while dual nano-spark shadowgraph technique was used to study the spray droplet behavior. The results show that RO has very poor atomization due to the high viscosity nature of the fuel. This is in agreement with the results from spray droplet dynamic behavior studies that shows due to the high viscosity, the droplets are large in size and travel downward, with very little influence of entrainment effect due to its large kinematic energy.

  16. Probing Dense Sprays with Gated, Picosecond, Digital Particle Field Holography

    Directory of Open Access Journals (Sweden)

    James Trolinger

    2011-12-01

    Full Text Available This paper describes work that demonstrated the feasibility of producing a gated digital holography system that is capable of producing high-resolution images of three-dimensional particle and structure details deep within dense particle fields of a spray. We developed a gated picosecond digital holocamera, using optical Kerr cell gating, to demonstrate features of gated digital holography that make it an exceptional candidate for this application. The Kerr cell gate shuttered the camera after the initial burst of ballistic and snake photons had been recorded, suppressing longer path, multiple scattered illumination. By starting with a CW laser without gating and then incorporating a picosecond laser and an optical Kerr gate, we were able to assess the imaging quality of the gated holograms, and determine improvement gained by gating. We produced high quality images of 50–200 μm diameter particles, hairs and USAF resolution charts from digital holograms recorded through turbid media where more than 98% of the light was scattered from the field. The system can gate pulses as short as 3 mm in pathlength (10 ps, enabling image-improving features of the system. The experiments lead us to the conclusion that this method has an excellent capability as a diagnostics tool in dense spray combustion research.

  17. Clinical analysis of cerebral venous sinus thrombosis and its combined treatment of anticoagulation and endovascular thrombolysis

    Directory of Open Access Journals (Sweden)

    Yun JIANG

    2018-01-01

    Full Text Available Objective To investigate the clinical and imaging manifestations of cerebral venous sinus thrombosis (CVST, and the clinical effect of combined treatment of anticoagulation and endovascular thrombolysis. Methods and Results The clinical manifestations of 22 CVST patients were highly variable. Headache (90.91%, 20/22 was the most frequent symptom, and conscious disturbance, seizure and focal neurological deficits were commonly present. Plasma D-dimer level was elevated in 12 patients (54.55%. Lumbar puncture was performed in 14 patients, in whom intracranial hypertension was present in 9 patients (9/14 with no characteristic changes in routine and biochemical examination of cerebrospinal fluid (CSF. Brain CT/MRI and CTV/MRV showed direct signs of CVST in all 22 patients, involving superior sagittal sinus, transverse sinus, sigmoid sinus, straight sinus and cortex veins, parenchymal lesions (infarction, hemorrhage and white matter abnormalities in 13 patients (59.09%, subarachnoid hemorrhage (SAH in 2 patients (9.10% and subdural hematoma in one patient (4.55%. The involved cerebral sinuses revealed by DSA were superior sagittal sinus in 13 patients (59.09% , transverse sinus in 17 patients (77.27%, sigmoid sinus in 14 patients (63.64%, inferior sagittal sinus in 2 patients (9.10%, straight sinus in 4 patients (18.18%, vein of Galen in one patient (4.55% and jugular vein in one patient (4.55%. Two thrombosed sinuses were found in 9 patients (40.91% and 3 or more thrombosed sinuses in 8 patients (36.36% . As no clinical improvements and progressive exacerbation were observed several days after heparin sodium intravenous drip or lower molecular weight heparin (LMWH hypodermic injection with oral warfarin anticoagulant therapy, urokinase thrombolysis in venous sinus or artery was applied in 21 patients (95.45%. After (25.70 ± 12.18 d treatment with anticoagulation, the modified Rankin Scale (mRS score of 13 patients (59.09% reached 0-1, 4 patients

  18. Characteristics of combustion flame sprayed nickel aluminum using a Coanda Assisted Spray Manipulation collar for off-normal deposits

    Science.gov (United States)

    Archibald, Reid S.

    A novel flame spray collar called the Coanda Assisted Spray Manipulation collar (CSM) has been tested for use on the Sulzer Metco 5P II combustion flame spray gun. A comparison study of the stock nozzle and the CSM has been performed by evaluating the porosity, surface roughness, microhardness, tensile strength and microscopy of normal and off-normal sprayed NiAl deposits. The use of the CSM collar resulted in the need to position the sprayed coupons closer to the gun, which in turn affected the particle impact energy and particle temperatures of the NiAl powder. For the CSM, porosities had a larger scatterband, surface roughness was comparably the same, microhardness was lower, and tensile strength was higher. The microscopy analysis revealed a greater presence of unmelted particles and steeper intersplat boundaries for the CSM. For both processes, the porosity and surface roughness increased and the microhardness decreased as the spray angle decreased.

  19. Development of process data capturing, analysis and controlling for thermal spray techniques - SprayTracker

    Science.gov (United States)

    Kelber, C.; Marke, S.; Trommler, U.; Rupprecht, C.; Weis, S.

    2017-03-01

    Thermal spraying processes are becoming increasingly important in high-technology areas, such as automotive engineering and medical technology. The method offers the advantage of a local layer application with different materials and high deposition rates. Challenges in the application of thermal spraying result from the complex interaction of different influencing variables, which can be attributed to the properties of different materials, operating equipment supply, electrical parameters, flow mechanics, plasma physics and automation. In addition, spraying systems are subject to constant wear. Due to the process specification and the high demands on the produced coatings, innovative quality assurance tools are necessary. A central aspect, which has not yet been considered, is the data management in relation to the present measured variables, in particular the spraying system, the handling system, working safety devices and additional measuring sensors. Both the recording of all process-characterizing variables, their linking and evaluation as well as the use of the data for the active process control presuppose a novel, innovative control system (hardware and software) that was to be developed within the scope of the research project. In addition, new measurement methods and sensors are to be developed and qualified in order to improve the process reliability of thermal spraying.

  20. Safety of Early Carotid Artery Stenting after Systemic Thrombolysis: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Fabrizio Sallustio

    2012-01-01

    Full Text Available Background. Patients with acute ischemic stroke due to internal carotid artery (ICA disease are at high risk of early stroke recurrence. A combination of IV thrombolysis and early carotid artery stenting (CAS may result in more effective secondary stroke prevention. Objective. We tested safety and durability of early CAS following IV thrombolysis in stroke patients with residual stenosis in the symptomatic ICA. Methods. Of consecutive patients treated with IV rtPA, those with residual ICA stenosis ≥70% or 24 hours. The protocol included pre-rtPA MRI and MR angiography, and post-rtPA carotid ultrasound and CT angiography. Stroke severity was assessed by the NIH Stroke Scale (NIHSS. Three- and twelve-month stent patency was assessed by ultrasound. Twelve-month functional outcome was assessed by the modified Rankin Scale (mRS. Results. Of 145 consecutive IV rtPA-treated patients, 6 (4% underwent early CAS. Median age was 76 (range 67–78 years, median NIHSS at stroke onset was 12 (range 9–16 and 7 (range 7-8 before CAS. Median onset-to-CAS time was 48 (range 30–94 hours. A single self-expandable stent was implanted to cover the entire lesion in all patients. The procedure was uneventful in all patients. After 12 months, all patients had stent patency, and the functional outcome was favourable (mRS ≤ 2 in all but 1 patient experiencing a recurrent stroke for new-onset atrial fibrillation. Conclusion. This small case series of a single centre suggests that early CAS may be considered a safe alternative to CEA after IV rtPA administration in selected patients at high risk of stroke recurrence.

  1. Fundamental Study on the Effect of Spray Parameters on Characteristics of P3HT:PCBM Active Layers Made by Spray Coating

    Directory of Open Access Journals (Sweden)

    Yu Xie

    2015-08-01

    Full Text Available This paper is an attempt to elucidate the effects of the important spray characteristics on the surface morphology and light absorbance of spray-on P3HT:PCBM thin-films, used as an active layer in polymer solar cells (PSCs. Spray coating or deposition is a viable scalable technique for the large-scale, fast, and low-cost fabrication of solution-processed solar cells, and has been widely used for device fabrication, although the fundamental understanding of the underlying and controlling parameters, such as spray characteristics, droplet dynamics, and surface wettability, is still limited, making the results on device fabrication not reproducible and unreliable. In this paper, following the conventional PSC architecture, a PEDOT:PSS layer is first spin-coated on glass substrates, followed by the deposition of P3HT:PCBM using an automatic ultrasonic spray coating system, with a movable nozzle tip, to mimic an industrial manufacturing process. To gain insight, the effects of the spray carrier air pressure, the number of spray passes, the precursor flow rate, and precursor concentration are studied on the surface topography and light absorbance spectra of the spray-on films. Among the results, it is found that despite the high roughness of spray-on films, the light absorbance of the film is satisfactory. It is also found that the absorbance of spray-on films is a linear function of the number of spray passes or deposition layers, based on which an effective film thickness is defined for rough spray-on films. The effective thickness of a rough spray-on P3HT:PCBM film was found to be one-quarter of that of a flat film predicted by a simple mass balance.

  2. Effect of cause of iliac vein stenosis and extent of thrombus in the lower extremity on patency of iliac venous stent placed after catheter-directed thrombolysis of acute deep venous thrombosis in the lower extremity

    International Nuclear Information System (INIS)

    Jung, Sung Il; Choi, Young Ho; Yoon, Chang Jin; Lee, Min Woo; Chung, Jin Wook; Park, Jae Hyung

    2003-01-01

    To assess the CT findings of acute deep venous thrombosis (DVT) in a lower extremity prior to catheter-directed thrombolysis, and to evaluate their relevance to the patency of an iliac venous stent placed with the help of CT after catheter-directed thrombolysis of DVT. Fourteen patients [M:F=3:11; age, 33-68 (mean, 50.1) years] with acute symptomatic DVD of a lower extremity underwent CT before and after catheter-directed thrombolysis using an iliac venous stent. The mean duration of clinical symptoms was 5.0 (range, 1-14 days. The CT findings prior to thrombolysis were evaluated in terms of their anatomic cause and the extent of the thrombus, and in all patients, the patency of the iliac venous stent was assessed at CT performed during a follow-up period lasting 6-31 (mean, 18.9) months. All patients were assigned to the patent stent group (n=9) or the occluded stent group (n=5). In the former, the anatomic cause of patency included typical iliac vein compression (May-Thurner syndrome) (n=9), and a relatively short segmental thrombus occurring between the common iliac and the popliteal vein (n=8). Thrombi occurred in the iliac vein (n=3), between the common iliac and the femoral vein (n=3), and between the common iliac and the popliteal vein (n=2). In one case, a relatively long segmental thrombus occurred between the common iliac vein and the calf vein. In the occluded stent group, anatomic causes included atypical iliac vein compression (n=3) and a relatively long segmental thrombus between the common iliac and the calf vein (n=4). Typical iliac vein compression (May-Thurner syndrome) occurred in two cases, and a relatively short segmental thrombus between the external iliac and the common femoral vein in one. Factors which can affect the patency of an iliac venous stent positioned after catheter-directed thrombolysis are the anatomic cause of the stenosis, and the extent of a thrombus revealed at CT of acute DVT and occurring in a lower extremity prior to

  3. Effect of cause of iliac vein stenosis and extent of thrombus in the lower extremity on patency of iliac venous stent placed after catheter-directed thrombolysis of acute deep venous thrombosis in the lower extremity

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sung Il; Choi, Young Ho; Yoon, Chang Jin; Lee, Min Woo; Chung, Jin Wook; Park, Jae Hyung [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2003-10-01

    To assess the CT findings of acute deep venous thrombosis (DVT) in a lower extremity prior to catheter-directed thrombolysis, and to evaluate their relevance to the patency of an iliac venous stent placed with the help of CT after catheter-directed thrombolysis of DVT. Fourteen patients [M:F=3:11; age, 33-68 (mean, 50.1) years] with acute symptomatic DVD of a lower extremity underwent CT before and after catheter-directed thrombolysis using an iliac venous stent. The mean duration of clinical symptoms was 5.0 (range, 1-14 days. The CT findings prior to thrombolysis were evaluated in terms of their anatomic cause and the extent of the thrombus, and in all patients, the patency of the iliac venous stent was assessed at CT performed during a follow-up period lasting 6-31 (mean, 18.9) months. All patients were assigned to the patent stent group (n=9) or the occluded stent group (n=5). In the former, the anatomic cause of patency included typical iliac vein compression (May-Thurner syndrome) (n=9), and a relatively short segmental thrombus occurring between the common iliac and the popliteal vein (n=8). Thrombi occurred in the iliac vein (n=3), between the common iliac and the femoral vein (n=3), and between the common iliac and the popliteal vein (n=2). In one case, a relatively long segmental thrombus occurred between the common iliac vein and the calf vein. In the occluded stent group, anatomic causes included atypical iliac vein compression (n=3) and a relatively long segmental thrombus between the common iliac and the calf vein (n=4). Typical iliac vein compression (May-Thurner syndrome) occurred in two cases, and a relatively short segmental thrombus between the external iliac and the common femoral vein in one. Factors which can affect the patency of an iliac venous stent positioned after catheter-directed thrombolysis are the anatomic cause of the stenosis, and the extent of a thrombus revealed at CT of acute DVT and occurring in a lower extremity prior to

  4. Metabolic Syndrome Predicts Refractoriness to Intravenous Thrombolysis in Acute Ischemic Stroke.

    Science.gov (United States)

    Dorado, Laura; Arenillas, Juan F; López-Cancio, Elena; Hernández-Pérez, María; Pérez de la Ossa, Natalia; Gomis, Meritxell; Millán, Mònica; Granada, María Luisa; Galán, Amparo; Palomeras, Ernest; Dávalos, Antoni

    2015-11-01

    Metabolic syndrome (MetS) has been associated with higher resistance to clot lysis at 24 hours after tissue plasminogen activator (tPA) administration in patients with acute ischemic stroke. We aimed to test this hypothesis at earlier time points, when neurointerventional rescue procedures may still be indicated to achieve arterial recanalization. This is a prospective and observational study in consecutive stroke patients with MCA occlusion treated with IV tPA. MetS was diagnosed following the unified criteria of the last Joint Interim Statement 2009 participating several major organizations. The primary outcome variable was resistance to thrombolysis, defined as the absence of complete middle cerebral artery recanalization 2 hours after tPA bolus assessed by transcranial color-coded duplex or when rescue mechanical thrombectomy after IV tPA was required. Secondary outcome variables were dramatic neurological improvement (decrease in ≥10 points, or a National Institutes of Health Stroke Scale [NIHSS] score of 0-1 at 24 hours), symptomatic intracerebral hemorrhage following European-Australasian Acute Stroke Study II criteria, infarct volume at 24 hours (calculated by using the formula for irregular volumes, ABC/2), and good outcome (modified Rankin Scale score < 3) at 3 months. A total of 234 patients (median baseline NIHSS score 16 [10-20]) were included and 146 (62.4%) fulfilled MetS criteria. After multivariate analysis, MetS emerged as an independent predictor of resistance to thrombolysis (odds ratio = 2.2 [1.3-4.2], P = .01) and absence of dramatic neurological improvement (odds ratio = .5 [.28-.97], P = .04). In addition, MetS conferred poorer functional outcome, higher symptomatic intracerebral hemorrhage rate, and increased infarct volume, although these associations disappeared after adjustment for covariates. MetS predicts patients with middle cerebral artery occlusion refractory to early clot dissolution after IV tPA. This

  5. Fine Sprays for Disinfection within Healthcare

    Directory of Open Access Journals (Sweden)

    G Nasr

    2016-09-01

    Full Text Available Problems exist worldwide with Hospital Acquired Infections (HAI's. The Spray Research Group (SRG have been working with relevant industries in developing a product which can provide a delivery system for treatment chemicals for surfaces, including the design and testing of a novel Spill-Return Atomiser (SRA for this purpose. A comprehensive description of this atomiser has already been given. This paper reports on a new application of this atomiser and discusses the problem of spray coating for disinfection that has been considered very little in previous work. The related spray coating performance tests in developing the product are thus provided. The experimental work includes determining the required spray duration and the coverage area produced by different sprays, including the analysis of the effects of atomiser positions, configurations, and the required number of atomisers. Comparison is made with the efficacy of an ultrasonic gas atomiser that is currently used for this purpose. The investigation has found that the utilisation of fine sprays (10μm>D32>25μm at high liquid pressure (<12MPa and low flow rates (<0.3 l/min is suitable for surface disinfection in healthcare applications (i.e. MRSA, VRSA etc.

  6. Method and Apparatus for Thermal Spraying of Metal Coatings Using Pulsejet Resonant Pulsed Combustion

    Science.gov (United States)

    Paxson, Daniel E. (Inventor)

    2014-01-01

    An apparatus and method for thermal spraying a metal coating on a substrate is accomplished with a modified pulsejet and optionally an ejector to assist in preventing oxidation. Metal such as Aluminum or Magnesium may be used. A pulsejet is first initiated by applying fuel, air, and a spark. Metal is inserted continuously in a high volume of metal into a combustion chamber of the pulsejet. The combustion is thereafter controlled resonantly at high frequency and the metal is heated to a molten state. The metal is then transported from the combustion chamber into a tailpipe of said pulsejet and is expelled therefrom at high velocity and deposited on a target substrate.

  7. Multiphysics modelling of the spray forming process

    International Nuclear Information System (INIS)

    Mi, J.; Grant, P.S.; Fritsching, U.; Belkessam, O.; Garmendia, I.; Landaberea, A.

    2008-01-01

    An integrated, multiphysics numerical model has been developed through the joint efforts of the University of Oxford (UK), University of Bremen (Germany) and Inasmet (Spain) to simulate the spray forming process. The integrated model consisted of four sub-models: (1) an atomization model simulating the fragmentation of a continuous liquid metal stream into droplet spray during gas atomization; (2) a droplet spray model simulating the droplet spray mass and enthalpy evolution in the gas flow field prior to deposition; (3) a droplet deposition model simulating droplet deposition, splashing and re-deposition behavior and the resulting preform shape and heat flow; and (4) a porosity model simulating the porosity distribution inside a spray formed ring preform. The model has been validated against experiments of the spray forming of large diameter IN718 Ni superalloy rings. The modelled preform shape, surface temperature and final porosity distribution showed good agreement with experimental measurements

  8. Water spray interaction with air-steam mixtures under containment spray conditions: comparison of heat and mass transfer modelling with the TOSQAN spray tests

    International Nuclear Information System (INIS)

    Malet, J.; Lemaitre, P.; Porcheron, E.; Vendel, J.

    2005-01-01

    Full text of publication follows: During the course of a hypothetical severe accident in a Pressurized Water Reactor (PWR), hydrogen can be produced by the reactor core oxidation and distributed into the reactor containment according to convection flows and water steam wall condensation. In order to mitigate the risk of detonation generated by a high local hydrogen concentration, spray systems are used in the containment. The TOSQAN programme has been created to simulate separate-effect tests representative of typical accidental thermal-hydraulic flow conditions in the reactor containment. The present work concerns the interaction of a water spray, used at the top of the containment in order to reduce the steam partial pressure, with air-steam mixtures. The main phenomena occurring when water spray is used are the mixing induced by spray entrainment and the condensation on droplets. In order to improve the latter phenomena, different levels of modelling can be used. The objective of this paper is to analyze experimental results obtained for water spray interaction with air-steam mixtures using different heat and mass transfer modelling. For this purpose, two modelling issues have been used: the first one is devoted for the determination of the gas thermodynamical properties, and the second one concerns the droplets characterization. In the first one, the gas thermodynamical analysis is performed using depressurization, gas temperature variation and humidity decrease during the spray injection. In this modelling, heat and mass transfer between the spray and the surrounding gas is treated in a global way by energy balance between the total amount of water and the gas. In the second one, droplets characterization is obtained by means of droplet size, temperature and velocities evolutions. In this modelling, the spray is considered as a single droplet falling with an initial velocity. Droplet interactions are neglected. Assessment of these two modelling is performed

  9. Fluctuations of a spray generated by an airblast atomizer

    Energy Technology Data Exchange (ETDEWEB)

    Batarseh, Feras Z.; Gnirss, Markus; Roisman, Ilia V.; Tropea, Cameron [Technische Universitaet Darmstadt (Germany). Chair of Fluid Mechanics and Aerodynamics

    2009-06-15

    This paper is devoted to the study of the aerodynamic instability of the spray generated by an airblast atomizer. As a result of this instability the spray shape and its velocity fluctuate with a certain frequency, which depends on the operational parameters of the atomizer. The effect of three parameters, namely; chamber pressure, liquid phase flow rate and the gas phase flow rate on the spray fluctuating frequency are investigated. The velocity vector of the drops in the spray and the arrival times to the detection volume are measured using the laser Doppler instrument. The slotting technique is applied to the data of axial velocity and arrival times of the drops in order to estimate the dominating spray frequencies. Additionally, the shape of the spray has been observed using the high-speed video system. The frequencies of the shape fluctuations are estimated using proper orthogonal decomposition of the time-resolved images of the spray. We show that the frequencies of the spray velocity and those exhibited by spray shape coincide over a wide range of spray parameters. Finally, a simple scaling for the spray frequency is proposed and validated by the experimental data. (orig.)

  10. Investigation of the causes of clinical symptom aggravation in process of intravenous thrombolysis with alteplase

    Directory of Open Access Journals (Sweden)

    LI Chen-hua

    2013-04-01

    Full Text Available Objective To explore the causes of aggravation of microcirculation disorders in the process of intravenous thrombolysis with alteplase and the clinical outcomes. Methods The clinical data of the aggravated signs and symptoms of 13 cases treated by alteplase were reported, and the onset characteristics and clinical outcomes were analysed to summarize emergency experiences. Results There were 13 patients with stenosis of intracranial large arteries occurred perforating branch infarctions caused by the blocking of carried arteries (8 cases in internal carotid system, 5 cases in vertebral-basilar system. In the process of thrombolytic therapy, main aggravated presentations including cortical ischemic symptom, quadriplegia, exacerbated disturbance of consciousness were seen. Imaging examinations showed multiple new petechial ischemic foci in cortex and watershed region or increasing of infarct foci in cerebellum and brain stem. The prognosis was favorable after expectant treatment. NIHSS score was 8.69 ± 3.42 at 24 h after treatment, and mRS score was 0.94 ±0.37 at 3 month-follow-up. Neurologic deficit and quality of life were evidently improved. Conclusion In the course of intravenous thrombolytic therapy with alteplase. Aggravated clinical signs and symptoms may be related to various factors. Emboli disintegration inducing microcirculation disorder is inferred to be the main cause. For patients presenting aggravated signs and symptoms in thrombolysis process, favorable outcomes may occur as long as intensive care and timely treatment are performed.

  11. Spray casting project final report

    International Nuclear Information System (INIS)

    Churnetski, S.R.; Thompson, J.E.

    1996-08-01

    Lockheed Martin Energy Systems, Inc. (Energy Systems), along with other participating organizations, has been exploring the feasibility of spray casting depleted uranium (DU) to near-net shape as a waste minimization effort. Although this technology would be useful in a variety of applications where DU was the material of choice, this effort was aimed primarily at gamma-shielding components for use in storage and transportation canisters for high-level radioactive waste, particularly in the Multipurpose Canister (MPC) application. In addition to the waste-minimization benefits, spray casting would simplify the manufacturing process by allowing the shielding components for MPC to be produced as a single component, as opposed to multiple components with many fabrication and assembly steps. In earlier experiments, surrogate materials were used to simulate the properties (specifically reactivity and density) of DU. Based on the positive results from those studies, the project participants decided that further evaluation of the issues and concerns that would accompany spraying DU was warranted. That evaluation occupied substantially all of Fiscal Year 1995, yielding conceptual designs for both an intermediate facility and a production facility and their associated engineering estimates. An intermediate facility was included in this study to allow further technology development in spraying DU. Although spraying DU to near-net shape seems to be feasible, a number of technical, engineering, and safety issues would need to be evaluated before proceeding with a production facility. This report is intended to document the results from the spray-casting project and to provide information needed by anyone interested in proceeding to the next step

  12. Helsinki Stroke Model Is Transferrable With “Real-World” Resources and Reduced Stroke Thrombolysis Delay to 34 min in Christchurch

    Directory of Open Access Journals (Sweden)

    Teddy Y. Wu

    2018-04-01

    Full Text Available BackgroundChristchurch hospital is a tertiary hospital in New Zealand supported by five general neurologists with after-hours services provided mainly by onsite non-neurology medical residents. We assessed the transferrability and impact of the Helsinki Stroke model on stroke thrombolysis door-to-needle time (DNT in Christchurch hospital.MethodsKey components of the Helsinki Stroke model were implemented first in 2015 with introduction of patient pre-notification and thrombolysis by the computed tomography (CT suite, followed by implementation of direct transfer to CT on ambulance stretcher in May 2017. Data from the prospective thrombolysis registry which began in 2012 were analyzed for the impact of these interventions on median DNT.ResultsBetween May and December 2017, 46 patients were treated with alteplase, 25 (54% patients were treated in-hours (08:00–17:00 non-public holiday weekdays and 21 (46% patients were treated after-hours. The in-hours, after-hours, and overall median (interquartile range DNTs were 34 (28–43, 47 (38–60, and 40 (30–51 minutes. The corresponding times in 2012–2014 prior to interventions were 87 (68–106, 86 (72–116, and 87 (71–112 minutes, representing median DNT reduction of 53, 39, and 47 minutes, respectively (p-values <0.01. The interventions also resulted in significant reductions in the overall median door-to-CT time (from 49 to 19 min, CT-to-needle time (32 to 20 min and onset-to-needle time (168 to 120 min.ConclusionThe Helsinki stroke model is transferrable with real-world resources and reduced stroke DNT in Christchurch by over 50%.

  13. Thermally sprayed coatings: Aluminum on lead

    International Nuclear Information System (INIS)

    Usmani, S.; Czajkowski, C.J.; Zatorski, R.

    1999-01-01

    An experimental program to determine the feasibility of thermally spraying aluminum on a lead substrate was initiated in support of the accelerator production of tritium (APT) Project for the US Department of Energy. The program consisted of two distinct parts: (1) the characterization of the thermally sprayed coatings, including microhardness testing, effects of heating, and microstructure and porosity determinations, and (2) effects of mercury doping and heat treatments on the thermally sprayed composite. The project determined that aluminum could successfully be thermally sprayed onto the lead. The coatings had a dense microstructure, with a Vicker's Pyramid Hardness (VPH) of about 60, and a maximum porosity (found in strips on the samples) of 12%

  14. Structure of Non-evaporating diesel sprays

    International Nuclear Information System (INIS)

    Mirza, M.R.; Baluch, A.H.; Tahir, Z.R.

    2008-01-01

    Need is always felt of some rational experimental information on fuel spray jet formation, its development and dispersion in the combustion chamber of an internal combustion engine. The latest study uses computational fluid dynamics for the modeling of engine flows. The original experimental work of the present author on non-evaporating sprays produced by a single-hole orifice type nozzle using a distribution type commercial fuel injection pump forms the basis to derive correlations for penetration rates, break up times and lengths of non-evaporating diesel sprays. The correlations derived can be used to do CFD modeling of sprays under variable conditions of injector nozzle hole diameter, fuel injection pressure and combustion chamber pressure. (author)

  15. Water spray ventilator system for continuous mining machines

    Science.gov (United States)

    Page, Steven J.; Mal, Thomas

    1995-01-01

    The invention relates to a water spray ventilator system mounted on a continuous mining machine to streamline airflow and provide effective face ventilation of both respirable dust and methane in underground coal mines. This system has two side spray nozzles mounted one on each side of the mining machine and six spray nozzles disposed on a manifold mounted to the underside of the machine boom. The six spray nozzles are angularly and laterally oriented on the manifold so as to provide non-overlapping spray patterns along the length of the cutter drum.

  16. A new method for spray deposit assessment

    Science.gov (United States)

    Chester M. Himel; Leland Vaughn; Raymond P. Miskus; Arthur D. Moore

    1965-01-01

    Solid fluorescent particles suspended in a spray liquid are distributed in direct proportion to the size of the spray droplets. Use of solid fluorescent particles is the basis of a new method for visual recognition of the size and number of droplets impinging on target and nontarget portions of sprayed areas.

  17. A simplified model of aerosol removal by containment sprays

    Energy Technology Data Exchange (ETDEWEB)

    Powers, D.A. (Sandia National Labs., Albuquerque, NM (United States)); Burson, S.B. (Nuclear Regulatory Commission, Washington, DC (United States). Div. of Safety Issue Resolution)

    1993-06-01

    Spray systems in nuclear reactor containments are described. The scrubbing of aerosols from containment atmospheres by spray droplets is discussed. Uncertainties are identified in the prediction of spray performance when the sprays are used as a means for decontaminating containment atmospheres. A mechanistic model based on current knowledge of the physical phenomena involved in spray performance is developed. With this model, a quantitative uncertainty analysis of spray performance is conducted using a Monte Carlo method to sample 20 uncertain quantities related to phenomena of spray droplet behavior as well as the initial and boundary conditions expected to be associated with severe reactor accidents. Results of the uncertainty analysis are used to construct simplified expressions for spray decontamination coefficients. Two variables that affect aerosol capture by water droplets are not treated as uncertain; they are (1) [open quote]Q[close quote], spray water flux into the containment, and (2) [open quote]H[close quote], the total fall distance of spray droplets. The choice of values of these variables is left to the user since they are plant and accident specific. Also, they can usually be ascertained with some degree of certainty. The spray decontamination coefficients are found to be sufficiently dependent on the extent of decontamination that the fraction of the initial aerosol remaining in the atmosphere, m[sub f], is explicitly treated in the simplified expressions. The simplified expressions for the spray decontamination coefficient are given. Parametric values for these expressions are found for median, 10 percentile, and 90 percentile values in the uncertainty distribution for the spray decontamination coefficient. Examples are given to illustrate the utility of the simplified expressions to predict spray decontamination of an aerosol-laden atmosphere.

  18. Effect of spray volume on the deposition, viability and infectivity of entomopathogenic nematodes in a foliar spray on vegetables.

    Science.gov (United States)

    Brusselman, Eva; Beck, Bert; Pollet, Sabien; Temmerman, Femke; Spanoghe, Pieter; Moens, Maurice; Nuyttens, David

    2012-10-01

    Spray volume can influence the amount of free water on the leaf surface and subsequently the ability of entomopathogenic nematodes (EPNs) to move. In this study, an investigation was made of the effect of spray volume (548, 730 and 1095 L ha(-1) ) on the deposition, viability and infectivity of EPNs against Galleria mellonella on savoy cabbage, cauliflower and leek. Increasing spray volume decreased nematode deposition on 7.1 cm2 leek leaf discs at a 15° angle with the spray nozzle. Although the number of living nematodes observed on leek after 240 min of exposure was not significantly different between the low-volume application (548 L ha(-1) ) and the high-volume application (1095 L ha(-1) ), a greater infectivity was obtained in the latter application. The higher number of droplets deposited on the leek discs in the high-volume application may have stimulated nematode movement. No significant effect of spray volume was observed on the relative deposition of Steinernema carpocapsae on the bottom side of cauliflower and savoy cabbage leaf discs. In spite of the low S. carpocapsae deposition on the bottom side of the savoy cabbage discs, high infectivity was obtained against G. mellonella. Using the lowest spray volume on savoy cabbage, infectivity decreased with increasing exposure time, while infectivity was not affected by exposure time when a spray volume of 730 L ha(-1) or more was used. Spray volume is an important application parameter, as it affects nematode infectivity. Future research should investigate the effect of spray volume in the field and its influence on the effect of adjuvants. Copyright © 2012 Society of Chemical Industry.

  19. Albendazole Microparticles Prepared by Spray Drying Technique ...

    African Journals Online (AJOL)

    Purpose: To enhance the dissolution of albendazole (ABZ) using spray-drying technique. Method: ABZ binary mixtures with Kollicoat IR® (KL) and polyvinyl pyrrolidone (PVP) in various drug to polymer ratios (1: 1, 1: 2 and 1; 4) were prepared by spray-drying. The spray-dried particles were characterized for particle shape, ...

  20. CHARACTERIZATION OF DIESEL SPRAY IMAGES USING A SHAPE PROCESSING METHODOLOGY

    Directory of Open Access Journals (Sweden)

    Cecile Petit

    2011-05-01

    Full Text Available In Diesel engines, a key element in achieving a clean and efficient combustion process is a proper fuel-air mixing, which is a consequence of the fuel spray development and fuel-air interaction inside the engine combustion chamber. The spray structure and behavior are classically described by the length (penetration and width (angle of the spray plume but these parameters do not give any clue on the geometrical injection center and on the spray symmetry. The purpose of this paper is to find out original tools to characterize the Diesel spray: the virtual spray origin is the geometrical injection center, which may (or may not coincide with the injector axis. Another interesting point is the description of the Diesel spray in terms of symmetry: the spray plume internal and external symmetry characterize the spray and the injector performance. Our approach is first to find out the virtual spray origin: after the image segmentation, the spray is coded with the Freeman code and with an original shape coding from which the moments are derived. The symmetry axes are then computed and the spray plumes are discarded (or not for the virtual spray origin computation, which is derived from a Voronoi diagram. The last step is the internal and external spray plume symmetry characterization thanks to correlation and mathematical distances.

  1. Quality characteristic of spray-drying egg white powders.

    Science.gov (United States)

    Ma, Shuang; Zhao, Songning; Zhang, Yan; Yu, Yiding; Liu, Jingbo; Xu, Menglei

    2013-10-01

    Spray drying is a useful method for developing egg process and utilization. The objective of this study was to evaluate effects on spray drying condition of egg white. The optimized conditions were spraying flow 22 mL/min, feeding temperature 39.8 °C and inlet-air temperature 178.2 °C. Results of sulfydryl (SH) groups measurement indicated conformation structure have changed resulting in protein molecule occur S-S crosslinking phenomenon when heating. It led to free SH content decreased during spray drying process. There was almost no change of differential scanning calorimetry between fresh egg white and spray-drying egg white powder (EWP). For a given protein, the apparent SH reactivity is in turn influenced by the physico-chemical characteristics of the reactant. The phenomenon illustrated the thermal denaturation of these proteins was unrelated to their free SH contents. Color measurement was used to study browning level. EWP in optimized conditions revealed insignificant brown stain. Swelling capacity and scanning electron micrograph both proved well quality characteristic of spray-drying EWP. Results suggested spray drying under the optimized conditions present suitable and alternative method for egg processing industrial implementation. Egg food industrialization needs new drying method to extend shelf-life. The purpose of the study was to provide optimal process of healthy and nutritional instant spray-drying EWP and study quality characteristic of spray-drying EWP.

  2. Spray drying of beryllium oxide powder

    International Nuclear Information System (INIS)

    Sepulveda, J.L.; Kahler, D.A.

    1991-01-01

    Forming of beryllia ceramics through dry pressing requires the agglomeration of the powder through spray drying. To produce high quality fired ceramics it is necessary to disperse/grind the primary powder prior to binder addition. Size reduction of the powder is accomplished using an aqueous system in Vibro-Energy mills (VEM) charged with beryllia media to minimize contamination. Two VEM mills of different size were used to characterize the grinding operation. Details of the grinding kinetics are described within the context of the Macroscopic Population Balance Model approach. Spray drying of the ceramic slurry was accomplished with both a centrifugal atomizer and a two fluid nozzle atomizer. Two different spray dryers were used. Important operating parameters affecting the size distribution of the spray dried powder are discussed

  3. LSPRAY-V: A Lagrangian Spray Module

    Science.gov (United States)

    Raju, M. S.

    2015-01-01

    LSPRAY-V is a Lagrangian spray solver developed for application with unstructured grids and massively parallel computers. It is mainly designed to predict the flow, thermal and transport properties of a rapidly vaporizing spray encountered over a wide range of operating conditions in modern aircraft engine development. It could easily be coupled with any existing gas-phase flow and/or Monte Carlo Probability Density Function (PDF) solvers. The manual provides the user with an understanding of various models involved in the spray formulation, its code structure and solution algorithm, and various other issues related to parallelization and its coupling with other solvers. With the development of LSPRAY-V, we have advanced the state-of-the-art in spray computations in several important ways.

  4. High-Performance Molybdenum Coating by Wire–HVOF Thermal Spray Process

    Science.gov (United States)

    Tailor, Satish; Modi, Ankur; Modi, S. C.

    2018-04-01

    Coating deposition on many industrial components with good microstructural, mechanical properties, and better wear resistance is always a challenge for the thermal spray community. A number of thermal spray methods are used to develop such promising coatings for many industrial applications, viz. arc spray, flame spray, plasma, and HVOF. All these processes have their own limitations to achieve porous free, very dense, high-performance wear-resistant coatings. In this work, an attempt has been made to overcome this limitation. Molybdenum coatings were deposited on low-carbon steel substrates using wire-high-velocity oxy-fuel (W-HVOF; WH) thermal spray system (trade name HIJET 9610®). For a comparison, Mo coatings were also fabricated by arc spray, flame spray, plasma spray, and powder-HVOF processes. As-sprayed coatings were analyzed using x-ray diffraction, scanning electron microscopy for phase, and microstructural analysis, respectively. Coating microhardness, surface roughness, and porosity were also measured. Adhesion strength and wear tests were conducted to determine the mechanical and wear properties of the as-sprayed coatings. Results show that the coatings deposited by W-HVOF have better performance in terms of microstructural, mechanical, and wear resistance properties, in comparison with available thermal spray process (flame spray and plasma spray).

  5. ASTRAL-R score predicts non-recanalisation after intravenous thrombolysis in acute ischaemic stroke.

    Science.gov (United States)

    Vanacker, Peter; Heldner, Mirjam R; Seiffge, David; Mueller, Hubertus; Eskandari, Ashraf; Traenka, Christopher; Ntaios, George; Mosimann, Pascal J; Sztajzel, Roman; Mendes Pereira, Vitor; Cras, Patrick; Engelter, Stefan; Lyrer, Philippe; Fischer, Urs; Lambrou, Dimitris; Arnold, Marcel; Michel, Patrik

    2015-05-01

    Intravenous thrombolysis (IVT) as treatment in acute ischaemic strokes may be insufficient to achieve recanalisation in certain patients. Predicting probability of non-recanalisation after IVT may have the potential to influence patient selection to more aggressive management strategies. We aimed at deriving and internally validating a predictive score for post-thrombolytic non-recanalisation, using clinical and radiological variables. In thrombolysis registries from four Swiss academic stroke centres (Lausanne, Bern, Basel and Geneva), patients were selected with large arterial occlusion on acute imaging and with repeated arterial assessment at 24 hours. Based on a logistic regression analysis, an integer-based score for each covariate of the fitted multivariate model was generated. Performance of integer-based predictive model was assessed by bootstrapping available data and cross validation (delete-d method). In 599 thrombolysed strokes, five variables were identified as independent predictors of absence of recanalisation: Acute glucose > 7 mmol/l (A), significant extracranial vessel STenosis (ST), decreased Range of visual fields (R), large Arterial occlusion (A) and decreased Level of consciousness (L). All variables were weighted 1, except for (L) which obtained 2 points based on β-coefficients on the logistic scale. ASTRAL-R scores 0, 3 and 6 corresponded to non-recanalisation probabilities of 18, 44 and 74 % respectively. Predictive ability showed AUC of 0.66 (95 %CI, 0.61-0.70) when using bootstrap and 0.66 (0.63-0.68) when using delete-d cross validation. In conclusion, the 5-item ASTRAL-R score moderately predicts non-recanalisation at 24 hours in thrombolysed ischaemic strokes. If its performance can be confirmed by external validation and its clinical usefulness can be proven, the score may influence patient selection for more aggressive revascularisation strategies in routine clinical practice.

  6. Searching for the Smoker's Paradox in Acute Stroke Patients Treated With Intravenous Thrombolysis.

    Science.gov (United States)

    Hussein, Haitham M; Niemann, Nicki; Parker, Emily D; Qureshi, Adnan I

    2017-07-01

    Inconsistent evidence supports better outcome in smokers after stroke. Our study examines this association in a large sample of ischemic stroke treated with intravenous thrombolysis. Virtual International Stroke Trials Archive (VISTA) database, composed of individual patient data of multiple clinical trials, was queried. The primary outcome was functional independence at 3 months noted by modified Rankin Scale (mRS; a 7-point scale ranging from 0 [no deficit] to 6 [death]) score≤ 2. The secondary outcomes were National Institutes of Health Stroke Scale (NIHSS; stroke severity measure, ranging from 0 [no deficit] to 42 [most severe]) score at 24 hours and the occurrence of symptomatic intractracranial hemorrhage. A total of 5383 patients were included: 1501 current smokers and 3882 nonsmokers. Smokers were younger (60 ± 13 vs. 71 ± 12 years, p vs. 13 [9-18], p smokers (49.7% vs. 39.5%, p non-significant after adjusting for age (OR 1.11, 95% CI 0.97-1.27). Subgroup analysis by age/gender strata showed that current smoking was associated with favorable outcome only in women ≥ 65 years. Current smoking was also associated with lower rates of symptomatic intracranial hemorrhage (adjusted OR 0.55, 95% CI 0.39-0.79). Smokers experience their first ever stroke 11 years younger than nonsmokers. This age difference explains the association between current smoking and favorable functional outcome. Smoking is associated with occurrence of first ever stroke at a younger age, therefore, focus should be on smoking prevention and treatment. The decision to treat ischemic stroke patients with intravenous thrombolysis should not be influenced by the patients' smoking status. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Characterization of the full cone pressure swirl spray nozzles for the nuclear reactor containment spray system

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Manish [Department of Mechanical Engineering, I.I.T., Bombay, Powai, Mumbai (India); John, Benny [Nuclear Power Corporation of India Limited, Mumbai (India); Iyer, K.N. [Department of Mechanical Engineering, I.I.T., Bombay, Powai, Mumbai (India); Prabhu, S.V., E-mail: svprabhu@iitb.ac.in [Department of Mechanical Engineering, I.I.T., Bombay, Powai, Mumbai (India)

    2014-07-01

    Highlights: • Full cone spray pressure swirl nozzle with X-Vane is studied. • Laser illuminated imaging technique is used. • Correlations for coefficient of discharge, spray cone angle and SMD are suggested. • Droplet size and mass fraction distribution is measured. • Inviscid theory predicts the coefficient of discharge. - Abstract: The objective of the present study is to characterize a full cone pressure swirl nozzle for the Containment Spray System (CSS) of Indian Pressurized heavy Water reactors (IPHWR). The influence of Reynolds number and geometric parameters on the coefficient of discharge, spray cone angle, mass flux density distribution, droplet size distribution, Sauter mean diameter (SMD is studied for full cone pressure swirl full cone nozzles. The nozzles of orifice diameter range from 1.3 to 7.2 mm are studied. Experiments are conducted with water at room temperature as the working medium. The nozzles are operated with the pressure ranging from 1 to 8 bar. The measurements of the drop size distributions are performed with laser illuminated imaging technique. The spray cone-angle of the full cone nozzles is measured by the evaluation of images recorded with a camera using IMAGE J software. Correlations for coefficient of discharge, spray cone angle and Sauter mean diameter are suggested on the basis of the experimental results. Rosin–Rammler model and Nukiyama–Tanasawa distributions predict the mass fraction distribution reasonably well. However, the droplet size distribution is predicted by Nukiyama-Tanasawa model only.

  8. Plasma spraying process of disperse carbides for spraying and facing

    International Nuclear Information System (INIS)

    Blinkov, I.V.; Vishnevetskaya, I.A.; Kostyukovich, T.G.; Ostapovich, A.O.

    1989-01-01

    A possibility to metallize carbides in plasma of impulsing capacitor discharge is considered. Powders granulation occurs during plasma spraying process, ceramic core being completely capped. X-ray phase and chemical analyses of coatings did not show considerable changes of carbon content in carbides before and after plasma processing. This distinguishes the process of carbides metallization in impulsing plasma from the similar processing in arc and high-frequency plasma generator. Use of powder composites produced in the impulsing capacitor discharge, for plasma spraying and laser facing permits 2-3 times increasing wear resistance of the surface layer as against the coatings produced from mechanical powders mixtures

  9. Alignment Fixtures For Vacuum-Plasma-Spray Gun

    Science.gov (United States)

    Woodford, William H.; Mckechnie, Timothy N.; Power, Christopher A.; Daniel, Ronald L., Jr.

    1993-01-01

    Fixtures for alignment of vacuum-plasma-spray guns built. Each fixture designed to fit specific gun and holds small, battery-powered laser on centerline of gun. Laser beam projects small red dot where centerline intersects surface of workpiece to be sprayed. After laser beam positioned on surface of workpiece, fixture removed from gun and spraying proceeds.

  10. Tungsten/copper composite deposits produced by a cold spray

    International Nuclear Information System (INIS)

    Kang, Hyun-Ki; Kang, Suk Bong

    2003-01-01

    An agglomerated tungsten/copper composite powder was both cold sprayed and plasma sprayed onto a mild steel substrate for electronic package applications. Most pores resulting from the spraying were found in the vicinity of the tungsten-rich regions of the final product. The levels of porosity varied with the amount of tungsten present. No copper oxidation was found at the cold-sprayed deposit, but relatively high copper oxidation was observed at the plasma-sprayed deposit

  11. Research Into Ni-Cr-Si-B Coating Sprayed Onto Aluminium Substrate Using the Method of Plasma Spray

    Directory of Open Access Journals (Sweden)

    Raimonda Lukauskaitė

    2013-02-01

    Full Text Available The article deals with Ni base coatings deposited on aluminium substrate applying the method of plasma spray. The purpose of the conducted research is to improve the physical and mechanical properties of coatings on the surface of aluminium alloy work pieces. Spraying on aluminium alloys encounters serious problems, and therefore this work analyses the ways to make the situation more favourable. Before spraying, the surfaces of substrates were modified employing chemical and mechanical pre-treatment methods. The aim of pre-treating aluminium alloys was to remove oxide layers from the aluminium surface. Coating microstructures and porosity were characterised applying optical microscopy. Differences in the roughness of pre-treated surfaces have been determined referring to profilometry. The paper investigates the influence of the adhesion of plasma spray coatings on aluminium surface pretreatment. Microhardness technique was applied for measuring the hardness of coatings. The study also describes and compares the mechanical properties of Ni base coatings deposited on different pre-treated aluminium substrates using plasma spray.Article in Lithuanian

  12. Research Into Ni-Cr-Si-B Coating Sprayed Onto Aluminium Substrate Using the Method of Plasma Spray

    Directory of Open Access Journals (Sweden)

    Raimonda Lukauskaitė

    2012-12-01

    Full Text Available The article deals with Ni base coatings deposited on aluminium substrate applying the method of plasma spray. The purpose of the conducted research is to improve the physical and mechanical properties of coatings on the surface of aluminium alloy work pieces. Spraying on aluminium alloys encounters serious problems, and therefore this work analyses the ways to make the situation more favourable. Before spraying, the surfaces of substrates were modified employing chemical and mechanical pre-treatment methods. The aim of pre-treating aluminium alloys was to remove oxide layers from the aluminium surface. Coating microstructures and porosity were characterised applying optical microscopy. Differences in the roughness of pre-treated surfaces have been determined referring to profilometry. The paper investigates the influence of the adhesion of plasma spray coatings on aluminium surface pretreatment. Microhardness technique was applied for measuring the hardness of coatings. The study also describes and compares the mechanical properties of Ni base coatings deposited on different pre-treated aluminium substrates using plasma spray.Article in Lithuanian

  13. Multi-pulse shadowgraphic RGB illumination and detection for flow tracking

    Science.gov (United States)

    Menser, Jan; Schneider, Florian; Dreier, Thomas; Kaiser, Sebastian A.

    2018-06-01

    This work demonstrates the application of a multi-color LED and a consumer color camera for visualizing phase boundaries in two-phase flows, in particular for particle tracking velocimetry. The LED emits a sequence of short light pulses, red, green, then blue (RGB), and through its color-filter array, the camera captures all three pulses on a single RGB frame. In a backlit configuration, liquid droplets appear as shadows in each color channel. Color reversal and color cross-talk correction yield a series of three frozen-flow images that can be used for further analysis, e.g., determining the droplet velocity by particle tracking. Three example flows are presented, solid particles suspended in water, the penetrating front of a gasoline direct-injection spray, and the liquid break-up region of an "air-assisted" nozzle. Because of the shadowgraphic arrangement, long path lengths through scattering media lower image contrast, while visualization of phase boundaries with high resolution is a strength of this method. Apart from a pulse-and-delay generator, the overall system cost is very low.

  14. Sprayed concrete linings

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-12-01

    Sprayed concrete, or shotcrete, was invented in the 1920s for preserving dinosaur skeletons and was used underground initially in coalmines for the preservation and fine proofing of timber supports. Its use as a support lining in rock tunnelling was developed in the 1950s and 60s. The article surveys equipment available from major manufacturers and suppliers of concrete spraying equipment (Aliva, Cifa, GIA, Industri, Ingersoll Rand, etc.), specialist cement and additive manufacturers (Castle, Cement, Moria Carbotech). manufacturers of lattice girders and fibre reinforcement, and manufacturers of instrumentation for tunnel linings. 5 tabs., 9 photos.

  15. Computational Analysis of Spray Jet Flames

    Science.gov (United States)

    Jain, Utsav

    There is a boost in the utilization of renewable sources of energy but because of high energy density applications, combustion will never be obsolete. Spray combustion is a type of multiphase combustion which has tremendous engineering applications in different fields, varying from energy conversion devices to rocket propulsion system. Developing accurate computational models for turbulent spray combustion is vital for improving the design of combustors and making them energy efficient. Flamelet models have been extensively used for gas phase combustion because of their relatively low computational cost to model the turbulence-chemistry interaction using a low dimensional manifold approach. This framework is designed for gas phase non-premixed combustion and its implementation is not very straight forward for multiphase and multi-regime combustion such as spray combustion. This is because of the use of a conserved scalar and various flamelet related assumptions. Mixture fraction has been popularly employed as a conserved scalar and hence used to parameterize the characteristics of gaseous flamelets. However, for spray combustion, the mixture fraction is not monotonic and does not give a unique mapping in order to parameterize the structure of spray flames. In order to develop a flamelet type model for spray flames, a new variable called the mixing variable is introduced which acts as an ideal conserved scalar and takes into account the convection and evaporation of fuel droplets. In addition to the conserved scalar, it has been observed that though gaseous flamelets can be characterized by the conserved scalar and its dissipation, this might not be true for spray flamelets. Droplet dynamics has a significant influence on the spray flamelet and because of effects such as flame penetration of droplets and oscillation of droplets across the stagnation plane, it becomes important to accommodate their influence in the flamelet formulation. In order to recognize the

  16. Fibrin-Targeted Magnetic Resonance Imaging Allows In Vivo Quantification of Thrombus Fibrin Content and Identifies Thrombi Amenable for Thrombolysis

    Science.gov (United States)

    Jenkins, Julia; Modarai, Bijan; Wiethoff, Andrea J.; Phinikaridou, Alkystis; Grover, Steven P.; Patel, Ashish S.; Schaeffter, Tobias; Smith, Alberto; Botnar, Rene M.

    2014-01-01

    Objective Deep venous thrombosis is a major health problem. Thrombolytic therapies are effective in recanalizing the veins and preventing post-thrombotic complications, but there is no consensus on selection criteria. The aim of this study was to investigate a fibrin-specific MRI contrast agent (EP-2104R) for the accurate quantification of thrombus’ fibrin content in vivo and for the identification of thrombus suitable for thrombolysis. Approach and Results Venous thrombosis was induced in the inferior vena cava of 8- to 10-week-old male BALB/C mice and MRI performed 2, 4, 7, 10, 14, and 21 days later. Eighteen mice were scanned at each time point pre and 2 hours post injection of EP-2104R (8.0 μmol/kg) with 12 mice at each time point used to correlate fibrin contrast uptake with thrombus’ histological stage and fibrin content. Six mice at each time point were immediately subjected to intravascular thrombolytic therapy (10 mg/kg of tissue-type plasminogen activator). Mice were imaged to assess response to lytic therapy 24 hours after thrombolytic treatment. Two mice at each time point were scanned post injection of 0.2 mmol/kg of Gd-DTPA (gadolinium with diethylenetriaminepentacetate, Magnevist, Schering AG, Berlin, Germany) for control purpose. Contrast uptake was correlated positively with the fibrin content of the thrombus measured by Western blotting (R2=0.889; PThrombus relaxation rate (R1) post contrast and the change in visualized thrombus size on late gadolinium enhancement inversion recovery MRI pre–EP-2104R and post–EP-2104R injection were the best predictors for successful thrombolysis (area under the curve, 0.989 [95% confidence interval, 0.97–1.00] and 0.994 [95% confidence interval, 0.98–1.00] respectively). Conclusions MRI with a fibrin-specific contrast agent accurately estimates thrombus fibrin content in vivo and identifies thrombi that are amenable for thrombolysis. PMID:24723557

  17. The Fate of High-Density Lesions on the Non-contrast CT Obtained Immediately After Intra-arterial Thrombolysis in Ischemic Stroke Patients

    International Nuclear Information System (INIS)

    Jang, Yu Mi; Lee, Deok Hee; Kim, Ho Sung; Ryu, Chang Woo; Lee, Jeong Hyun; Choi, Choong Gon; Kim, Sang Joon; Suh, Dae Chul

    2006-01-01

    Hyperdense lesions can frequently be observed on the CT obtained immediately after intra-arterial (IA) thrombolysis, and it is sometimes difficult to differentiate contrast extravasation from the hemorrhagic lesions. The purposes of this study are to classify the hyperdense lesions according to their morphologic features and to track the outcome of those lesions. Among the 94 patients who suffered with anterior circulation ischemic stroke and who were treated with IA thrombolysis, 31 patients revealed hyperdense lesions on the CT obtained immediately after the procedure. The lesions were categorized into four types according to their volume, shape, location and density: cortical high density (HD), soft HD, metallic HD and diffuse HD. The follow-up images were obtained 3 5 days later in order to visualize the morphologic changes and hemorrhagic transformation of the lesions. Among the 31 patients with HD lesions, 18 (58%) showed hemorrhagic transformation of their lesion, and six of them were significant. All the cortical HD lesions (n = 4) revealed spontaneous resolution. Seven of the soft HD lesions (n = 13) showed spontaneous resolution, while the rest of the group showed hemorrhagic transformation. Among them the hemorrhage was significant in only two patients (2/6) who did not achieve successful recanalization. All the metallic HD lesions (n = 10) resulted in hemorrhagic transformation; among them, three cases (30%) with a maximum CT value more than 150 HU (Hounsfield unit) subsequently showed significant hemorrhagic transformation on the follow-up CT. There were four diffuse HD lesions, and two of them showed hemorrhagic transformation. The parenchymal hyperdense lesions observed on the CT obtained immediately after IA thrombolysis in ischemic stroke patients exhibited varying features and they were not always hemorrhagic. Most of the soft HD lesions were benign, and although all of the metallic HD lesions were hemorrhagic, some of them were ultimately found

  18. Impact of collateral circulation on early outcome and risk of hemorrhagic complications after systemic thrombolysis.

    Science.gov (United States)

    Brunner, Freimuth; Tomandl, Bernd; Hanken, Katrin; Hildebrandt, Helmut; Kastrup, Andreas

    2014-12-01

    In stroke patients, collateral flow can rapidly be assessed on computed tomography angiography (CTA). In this study, the impact of baseline collaterals on early outcome and risk of symptomatic intracerebral hemorrhages after systemic thrombolysis in patients with proximal arterial occlusions within the anterior circulation were analyzed. Collateralization scores were determined on the CT angiography source images (0 = absent; 1 ≤ 50%, 2 > 50% but collateral filling) of patients with distal intracranial carotid artery and/or M1 segment occlusions treated from 2008 to December 2011. A collateral score of 0 to 1 was designated as poor and 2 to 3 as good collateral vessel status. Outcome variables included in hospital mortality, favorable outcome at discharge (modified Rankin score ≤ 2), and rates of symptomatic intracerebral hemorrhage based on the European-Australasian Acute Stroke Study II definition. Among 246 subjects (mean age of 74 years; median National Institutes of Health Stroke Scale N at admission 14), 205 patients (83%) had good collaterals, whereas 41 patients (17%) had poor collaterals, respectively. Patients with poor collaterals had significantly higher rates of in-hospital mortality (41% vs. 12%, P collaterals. The grade of collateralization was independently associated with in-hospital mortality (P collaterals have a poor early functional outcome and high rates of symptomatic intracerebral hemorrhage after systemic thrombolysis. Since similar findings have also been reported after endovascular therapy, strategies to improve collateral blood flow should be assessed in this patient population. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.

  19. Plasma sprayed coatings on crankshaft used steels

    Science.gov (United States)

    Mahu, G.; Munteanu, C.; Istrate, B.; Benchea, M.

    2017-08-01

    Plasma spray coatings may be an alternative to conventional heat treatment of main journals and crankpins of the crankshaft. The applications of plasma coatings are various and present multiple advantages compared to electric arc wire spraying or flame spraying. The study examines the layers sprayed with the following powders: Cr3C2- 25(Ni 20Cr), Al2O3- 13TiO2, Cr2O3-SiO2- TiO2 on the surface of steels used in the construction of a crankshaft (C45). The plasma spray coatings were made with the Spray wizard 9MCE facility at atmospheric pressure. The samples were analyzed in terms of micro and morphological using optical microscopy, scanning electron microscopy and X-ray diffraction. Wear tests on samples that have undergone simulates extreme working conditions of the crankshafts. In order to emphasize adherence to the base material sprayed layer, were carried out tests of microscratches and micro-indentation. Results have showed a relatively compact morphological aspect given by the successive coatings with splat-like specific structures. Following the microscratch analysis it can be concluded that Al2O3-13TiO2 coating has a higher purpose in terms of hardness compared to Cr3C2-(Ni 20Cr) and Cr2O3-SiO2- TiO2 powders. Thermal coatings of the deposited powders have increased the mechanical properties of the material. The results stand to confirm that plasma sprayed Al2O3-13TiO2 powder is in fact a efficient solution for preventing mechanical wear, even with a faulty lubrication system.

  20. To spray or not to spray? Understanding participation in an indoor residual spray campaign in Arequipa, Peru.

    Science.gov (United States)

    Paz-Soldán, Valerie A; Bauer, Karin M; Hunter, Gabrielle C; Castillo-Neyra, Ricardo; Arriola, Vanessa D; Rivera-Lanas, Daniel; Rodriguez, Geoffrey H; Toledo Vizcarra, Amparo M; Mollesaca Riveros, Lina M; Levy, Michael Z; Buttenheim, Alison M

    2018-01-01

    Current low participation rates in vector control programmes in Arequipa, Peru complicate the control of Chagas disease. Using focus groups (n = 17 participants) and semi-structured interviews (n = 71) conducted in March and May 2013, respectively, we examined barriers to and motivators of household participation in an indoor residual spray (IRS) campaign that had taken place one year prior in Arequipa. The most common reported barriers to participation were inconvenient spray times due to work obligations, not considering the campaign to be necessary, concerns about secondary health impacts (e.g. allergic reactions to insecticides), and difficulties preparing the home for spraying (e.g. moving heavy furniture). There was also a low perception of risk for contracting Chagas disease that might affect participation. The main motivator to participate was to ensure personal health and well-being. Future IRS campaigns should incorporate more flexible hours, including weekends; provide appropriate educational messages to counter concerns about secondary health effects; incorporate peer educators to increase perceived risk to Chagas in community; obtain support from community members and leaders to build community trust and support for the campaign; and assist individuals in preparing their homes. Enhancing community trust in both the need for the campaign and its operations is key.

  1. Injector spray characterization of methanol in reciprocating engines

    Science.gov (United States)

    Dodge, L.; Naegeli, D.

    1994-06-01

    This report covers a study that addressed cold-starting problems in alcohol-fueled, spark-ignition engines by using fine-spray port-fuel injectors to inject fuel directly into the cylinder. This task included development and characterization of some very fine-spray, port-fuel injectors for a methanol-fueled spark-ignition engine. After determining the spray characteristics, a computational study was performed to estimate the evaporation rate of the methanol fuel spray under cold-starting and steady-state conditions.

  2. Development of cold sprayed Cu coating for canister

    International Nuclear Information System (INIS)

    Kim, Hyung Jun; Kang, Yoon Ha

    2010-01-01

    Cold sprayed Cu deposition was studied for the application of outer part of canister for high level nuclear waste. Five commercially available pure Cu powders were analyzed and sprayed by high pressure cold spray system. Electrochemical corrosion test using potentiostat in 3.5% NaCl solution was conducted as well as microstructural analysis including hardness and oxygen content measurements. Overall evaluation of corrosion performance of cold sprayed Cu deposition is inferior to forged and extruded Cu plates, but some of Cu depositions are comparable to Cu plates. The simulated corrosion test in 200m underground cave is still in progress. The effect of cold spray process parameters was also studied and the results show that the type of nozzle is the most important other than powder feed rate, spray distance, and scan speed. 1/10 scale miniature of canister was manufactured confirming that the production of full scale canister is possible

  3. Spray Modeling for Outwardly-Opening Hollow-Cone Injector

    KAUST Repository

    Sim, Jaeheon

    2016-04-05

    The outwardly-opening piezoelectric injector is gaining popularity as a high efficient spray injector due to its precise control of the spray. However, few modeling studies have been reported on these promising injectors. Furthermore, traditional linear instability sheet atomization (LISA) model was originally developed for pressure swirl hollow-cone injectors with moderate spray angle and toroidal ligament breakups. Therefore, it is not appropriate for the outwardly-opening injectors having wide spray angles and string-like film structures. In this study, a new spray injection modeling was proposed for outwardly-opening hollow-cone injector. The injection velocities are computed from the given mass flow rate and injection pressure instead of ambiguous annular nozzle geometry. The modified Kelvin-Helmholtz and Rayleigh-Taylor (KH-RT) breakup model is used with adjusted initial Sauter mean diameter (SMD) for modeling breakup of string-like structure. Spray injection was modeled using a Lagrangian discrete parcel method within the framework of commercial CFD software CONVERGE, and the new model was implemented through the user-defined functions. A Siemens outwardly-opening hollow-cone spray injector was characterized and validated with existing experimental data at the injection pressure of 100 bar. It was found that the collision modeling becomes important in the current injector because of dense spray near nozzle. The injection distribution model showed insignificant effects on spray due to small initial droplets. It was demonstrated that the new model can predict the liquid penetration length and local SMD with improved accuracy for the injector under study.

  4. Variation in Clinical Practice of Intravenous Thrombolysis in Stroke in the Netherlands

    Directory of Open Access Journals (Sweden)

    Auke Bauer

    2013-04-01

    Full Text Available In the Netherlands in 2010, 11% of patients with ischemic stroke received intravenous thrombolysis (IVT, varying from 4 to 26% between hospitals. The aim of this study was to investigate variation in clinical practice and organization of IVT in relationship to performance and outcome. In all 84 Dutch hospitals performing IVT, a stroke neurologist was approached using a web-based survey. The response rate was 82%. The study showed considerable variation. For example, door-to-needle time ranged from 25 to 80 min. High blood pressure was actively lowered before performing IVT by 57% of neurologists, while 35% chose to wait. 28% started IVT without knowledge of laboratory results. Better follow-up data are needed to see whether this variation results in differences in outcome.

  5. Plasminogen activator inhibitor-1 released from activated platelets plays a key role in thrombolysis resistance. Studies with thrombi generated in the Chandler loop

    NARCIS (Netherlands)

    Stringer, H. A.; van Swieten, P.; Heijnen, H. F.; Sixma, J. J.; Pannekoek, H.

    1994-01-01

    To investigate the potential role of plasminogen activator inhibitor-1 (PAI-1), which is released from the alpha-granules of activated platelets, in thrombolysis resistance, we employed a model (the "Chandler loop") that mimics the formation of arterial thrombi in vivo and that can be manipulated in

  6. Research of Plasma Spraying Process on Aluminum-Magnesium Alloy

    Directory of Open Access Journals (Sweden)

    Patricija Kavaliauskaitė

    2016-04-01

    Full Text Available The article examines plasma sprayed 95Ni-5Al coatings on alu-minum-magnesium (Mg ≈ 2,6‒3,6 % alloy substrate. Alumi-num-magnesium samples prior spraying were prepared with mechanical treatment (blasting with Al2O3. 95Ni-5Al coatings on aluminum-magnesium alloys were sprayed with different parameters of process and coating‘s thickness, porosity, micro-hardness and microstructure were evaluated. Also numerical simulations in electric and magnetic phenomena of plasma spray-ing were carried out.

  7. A new method for thermal spraying of Zn-Al coatings

    International Nuclear Information System (INIS)

    Gorlach, I.A.

    2009-01-01

    This paper presents the development of the thermal spraying system built on the principles of the high velocity air flame (HVAF) process. HVAF sprayed coatings showed considerably higher bond strength than coatings obtained by the conventional methods, indicating the advantage of this method in areas where the adhesion strength is critically important. The highly dense structure of the coating obtained with HVAF eliminates a need for a top paint coat, which is typically applied on metal sprayed coatings to extend service life. The thermal sprayed coatings were characterized by the standard techniques, such as light microscopy, scanning electron microscopy with energy-dispersive spectroscopy, X-ray diffraction, salt spray and bond strength tests. The results show that thermal sprayed coatings have a dense structure, low presence of oxides and high resistance to corrosion. High spray rate and good coating quality make the HVAF thermal spray method a viable alternative to the conventional thermal spraying technologies, such as Wire Flame and Twin-Wire Arc.

  8. Ternary ceramic thermal spraying powder and method of manufacturing thermal sprayed coating using said powder

    Energy Technology Data Exchange (ETDEWEB)

    Vogli, Evelina; Sherman, Andrew J.; Glasgow, Curtis P.

    2018-02-06

    The invention describes a method for producing ternary and binary ceramic powders and their thermal spraying capable of manufacturing thermal sprayed coatings with superior properties. Powder contain at least 30% by weight ternary ceramic, at least 20% by weight binary molybdenum borides, at least one of the binary borides of Cr, Fe, Ni, W and Co and a maximum of 10% by weight of nano and submicro-sized boron nitride. The primary crystal phase of the manufactured thermal sprayed coatings from these powders is a ternary ceramic, while the secondary phases are binary ceramics. The coatings have extremely high resistance against corrosion of molten metal, extremely thermal shock resistance and superior tribological properties at low and at high temperatures.

  9. Managing iliofemoral deep venous thrombosis of pregnancy with a strategy of thrombus removal is safe and avoids post-thrombotic morbidity.

    Science.gov (United States)

    Herrera, Santiago; Comerota, Anthony J; Thakur, Subhash; Sunderji, Shiraz; DiSalle, Robert; Kazanjian, Sahira N; Assi, Zakaria

    2014-02-01

    Extensive deep venous thrombosis (DVT) during pregnancy is usually treated with anticoagulation alone, risking significant post-thrombotic syndrome (PTS) in young patients. Catheter-directed thrombolysis (CDT) and operative venous thrombectomy have been safely and effectively used in nonpregnant patients, demonstrating significant reduction in post-thrombotic morbidity. This report reviews short- and long-term outcomes of 13 patients with extensive DVT of pregnancy treated with a strategy of thrombus removal. From 1999 to 2013, 13 patients with iliofemoral DVT during pregnancy were offered CDT, pharmacomechanical thrombolysis (PMT), and/or venous thrombectomy. Gestational age ranged from 8 to 34 weeks. Fetal monitoring was performed throughout hospitalization. Radiation exposure was minimized with pelvic lead shields, focal fluoroscopy, and limited angiographic runs. Follow-up included objective vein evaluation using venous duplex and PTS assessment using the Villalta scale. CDT and/or PMT were used in 11 patients. Two patients underwent venous thrombectomy alone, and one patient had operative thrombectomy as an adjunct to CDT and PMT. Each patient had complete or near-complete thrombus resolution and rapid improvement in clinical symptoms. Eight of 11 having CDT or PMT underwent venoplasty and stenting of the involved iliac veins. Twelve of the 13 delivered healthy infants at term. One patient opted for termination of her pregnancy. Mean patient and gestational ages were 26 years and 26 weeks, respectively. Mean follow-up was 1.3 years, with only one recurrence. Duplex ultrasonography demonstrated patent veins in all but one patient and normal valve function in 10 patients. Eleven patients had Villalta scores thrombus removal, resulting in a patent venous system, normal valve function in many, prevention of PTS, and reduction in recurrence. Copyright © 2014. Published by Mosby, Inc.

  10. Evaluation of mechanical properties of Aluminum-Copper cold sprayed and alloy 625 wire arc sprayed coatings

    Science.gov (United States)

    Bashirzadeh, Milad

    This study examines microstructural-based mechanical properties of Al-Cu composite deposited by cold spraying and wire arc sprayed nickel-based alloy 625 coating using numerical modeling and experimental techniques. The microhardness and elastic modulus of samples were determined using the Knoop hardness technique. Hardness in both transverse and longitudinal directions on the sample cross-sections has been measured. An image-based finite element simulation algorithm was employed to determine the mechanical properties through an inverse analysis. In addition mechanical tests including, tensile, bending, and nano-indentation tests were performed on alloy 625 wire arc sprayed samples. Overall, results from the experimental tests are in relatively good agreement for deposited Al-Cu composites and alloy 625 coating. However, results obtained from numerical simulation are significantly higher in value than experimentally obtained results. Examination and comparison of the results are strong indications of the influence of microstructure characteristics on the mechanical properties of thermally spray deposited coatings.

  11. Invited Review. Combustion instability in spray-guided stratified-charge engines. A review

    Energy Technology Data Exchange (ETDEWEB)

    Fansler, Todd D. [Univ. of Wisconsin, Madison, WI (United States); Reuss, D. L. [Univ. of Michigan, Ann Arbor, MI (United States); Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sick, V. [Univ. of Michigan, Ann Arbor, MI (United States); Dahms, R. N. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-02-02

    Our article reviews systematic research on combustion instabilities (principally rare, random misfires and partial burns) in spray-guided stratified-charge (SGSC) engines operated at part load with highly stratified fuel -air -residual mixtures. Results from high-speed optical imaging diagnostics and numerical simulation provide a conceptual framework and quantify the sensitivity of ignition and flame propagation to strong, cyclically varying temporal and spatial gradients in the flow field and in the fuel -air -residual distribution. For SGSC engines using multi-hole injectors, spark stretching and locally rich ignition are beneficial. Moreover, combustion instability is dominated by convective flow fluctuations that impede motion of the spark or flame kernel toward the bulk of the fuel, coupled with low flame speeds due to locally lean mixtures surrounding the kernel. In SGSC engines using outwardly opening piezo-electric injectors, ignition and early flame growth are strongly influenced by the spray's characteristic recirculation vortex. For both injection systems, the spray and the intake/compression-generated flow field influence each other. Factors underlying the benefits of multi-pulse injection are identified. Finally, some unresolved questions include (1) the extent to which piezo-SGSC misfires are caused by failure to form a flame kernel rather than by flame-kernel extinction (as in multi-hole SGSC engines); (2) the relative contributions of partially premixed flame propagation and mixing-controlled combustion under the exceptionally late-injection conditions that permit SGSC operation on E85-like fuels with very low NOx and soot emissions; and (3) the effects of flow-field variability on later combustion, where fuel-air-residual mixing within the piston bowl becomes important.

  12. SPRAY code user's report

    International Nuclear Information System (INIS)

    Shire, P.R.

    1977-03-01

    The SPRAY computer code has been developed to model the effects of postulated sodium spray release from LMFBR piping within containment chambers. The calculation method utilizes gas convection, heat transfer and droplet combustion theory to calculate the pressure and temperature effects within the enclosure. The applicable range is 0-21 mol percent oxygen and .02-.30 inch droplets with or without humidity. Droplet motion and large sodium surface area combine to produce rapid heat release and pressure rise within the enclosed volume

  13. Influence of powder and spray parameters on erosion and corrosion properties of HVOF sprayed WC-Co-Cr coatings

    Energy Technology Data Exchange (ETDEWEB)

    Berget, John

    1998-07-01

    Thermal spraying is a generic term including various processes used to deposit coatings on surfaces. The coating material is in the form of powder or a wire and is melted or softened by means of a heat source. A gas stream accelerates the material towards a prepared surface and deposits it there to form the coating. Examples of components being maintained by application of thermal spray coatings are gate valves and ball valves for the offshore industry and turbine blades in power generations installations. Recent investigation has shown that the commonly used coating material WC-Co is not corrosion resistant. But it can be improved by the addition of Cr. The main objective of this thesis is to study the influence of spray process control variables and powder characteristics on the erosion and erosion-corrosion properties of the coatings. Spray process variables investigated include energy input, powder feed rate and spray distance. Powder characteristics studied are average size of the WC particles, relative proportions of Co and Cr in the metal phase and powder grain size distribution.

  14. Cryogen spray cooling: Effects of droplet size and spray density on heat removal.

    Science.gov (United States)

    Pikkula, B M; Torres, J H; Tunnell, J W; Anvari, B

    2001-01-01

    Cryogen spray cooling (CSC) is an effective method to reduce or eliminate non-specific injury to the epidermis during laser treatment of various dermatological disorders. In previous CSC investigations, fuel injectors have been used to deliver the cryogen onto the skin surface. The objective of this study was to examine cryogen atomization and heat removal characteristics of various cryogen delivery devices. Various cryogen delivery device types including fuel injectors, atomizers, and a device currently used in clinical settings were investigated. Cryogen mass was measured at the delivery device output orifice. Cryogen droplet size profiling for various cryogen delivery devices was estimated by optically imaging the droplets in flight. Heat removal for various cryogen delivery devices was estimated over a range of spraying distances by temperature measurements in an skin phantom used in conjunction with an inverse heat conduction model. A substantial range of mass outputs were measured for the cryogen delivery devices while heat removal varied by less than a factor of two. Droplet profiling demonstrated differences in droplet size and spray density. Results of this study show that variation in heat removal by different cryogen delivery devices is modest despite the relatively large difference in cryogen mass output and droplet size. A non-linear relationship between heat removal by various devices and droplet size and spray density was observed. Copyright 2001 Wiley-Liss, Inc.

  15. An experimental study on atomizing formation process of diesel spray

    International Nuclear Information System (INIS)

    Kim, Ki Bong

    2000-02-01

    In this study, the experiment has, been conducted to investigate the spray characteristics under the parameter of an ambient pressure with a single hole nozzle having aspect ratio(L/D) of 5 and diameter of 0.45mm. Under the condition of the injection pressure of 14Mpa, the initial disintegrating process of a diesel spray is investigated and analysized according to change of the ambient pressures, 0.1, 1, 2 and 3Mpa. The double flash method has been employed to visualize the process of the diesel sprays. The results obtained in this study are as follows: 1) After spray starts, the spray is shown as non-disturbance liquid column within about 1∼2mm from the nozzle tip, whose diameter is similar to that of a nozzle. For the same injection pressure, the increase of the ambient pressure makes the length of the non-disturbance liquid column become short. 2) Due to the surface wave, ligaments of the shape thread appear at the boundary of liquid column right after spray. The more developed wave together the progress of spray transforms ligaments into droplets that have generally the uniformed size. 3) In case spraying into chambers having different ambient pressures, 1, 2, and 3Mpa, the spray tip velocities reach up to 1.5, 1.2, and 0.6ms, respectively, and decrease with lapse of time. The spray angle keeps increasing for 0.6, 1.2, and 1.4ms after spray under the various ambient pressures, 3, 2, and 1Mpa, respectively, and begins to decrease and maintains the constant value. Therefore, the transition points appear near the point where the velocity decreases and the spray angle increases, simultaneously. The higher ambient pressure leads to fast appearance of transition under the same spray pressure. 4) The disintegrating mechanism of the liquid spray is two combined effects: a) friction forces between the surface waves generated at the surface of the liquid column and the ambient gas, b) the collisions of liquid droplets and ligaments by spray were overtaking

  16. Aluminium-12wt% silicon coating prepared by thermal spraying technique: Part 1 optimization of spray condition based on a design of experiment

    Directory of Open Access Journals (Sweden)

    Jiansirisomboon, S.

    2006-03-01

    Full Text Available At present, thermal spray technology is used for maintenance parts of various machines in many industries. This technology can be used to improve the surface wear resistance. Therefore, this technology can significantly reduce cost of manufacturing. Al-12wt%Si alloy is an interesting and popular material used in the automotive industry. This research studies the suitable condition for spraying of Al-12wt%Si powder. This powder was sprayed by a flame spray technique onto low carbon steel substrates. The suitable conditions for spraying can be achieved by a design of experiment (DOE principle, which provided statistical data defined at 90% confidence. This research used control factors, which were oxygen flow rate, acetylene flow rate and spray distance. The satisfaction levels of these factors were set at 3 levels, i.e. low, medium and high, in order to determine suitable responses, which were hardness, thickness, wear rate and percentage volume fraction of porosity. It was found that the optimized condition for spraying Al-12wt%Si powder consisted of 38 ft3/hr (1.026 m3/hr of oxygen flow rate, 27 ft3/hr (0.729 m3/hr of acetylene flow rate and 58 mm of spray distance.

  17. Plasma sprayed Nd-Fe-B permanent magnets

    International Nuclear Information System (INIS)

    Willson, M.; Bauser, S.; Liu, S.; Huang, M.

    2003-01-01

    This study demonstrated that the plasma spray deposition method is an alternative process for producing Nd-Fe-B magnets in addition to the two existing principal processes: the powder metallurgy process for producing sintered Nd-Fe-B magnets and the melt spinning process for bonded Nd-Fe-B magnets. Plasma spray is a potentially better process for producing magnetic parts with complicated shape, large area, thin thickness, small dimension, or unusual geometry. High intrinsic coercivity greater than 15 kOe was readily obtained for Nd 16 Dy 1 Fe 76 B 7 even in the as-deposited condition when the substrate was preheated. The plasma spray process contains only three steps: melting, crushing, and plasma spray, which is much simpler than the powder metallurgy and melt spinning processes. Without preheating the substrate, the coercivity was usually very low (∼0.1 kOe) in the as-deposited condition and it increased to 10 to >15 kOe after anneal. Evidence of magnetocrystalline anisotropy was observed in plasma sprayed Nd 15 Dy 1 Fe 77 B 7 magnets when the substrate was not preheated. It is believed that a crystal texture was developed during the plasma spray as a result of the existence of a temperature gradient in the solidifying melt

  18. Nano spray drying for encapsulation of pharmaceuticals.

    Science.gov (United States)

    Arpagaus, Cordin; Collenberg, Andreas; Rütti, David; Assadpour, Elham; Jafari, Seid Mahdi

    2018-05-17

    Many pharmaceuticals such as pills, capsules, or tablets are prepared in a dried and powdered form. In this field, spray drying plays a critical role to convert liquid pharmaceutical formulations into powders. In addition, in many cases it is necessary to encapsulate bioactive drugs into wall materials to protect them against harsh process and environmental conditions, as well as to deliver the drug to the right place and at the correct time within the body. Thus, spray drying is a common process used for encapsulation of pharmaceuticals. In view of the rapid progress of nanoencapsulation techniques in pharmaceutics, nano spray drying is used to improve drug formulation and delivery. The nano spray dryer developed in the recent years provides ultrafine powders at nanoscale and high product yields. In this paper, after explaining the concept of nano spray drying and understanding the key elements of the equipment, the influence of the process parameters on the final powders properties, like particle size, morphology, encapsulation efficiency, drug loading and release, will be discussed. Then, numerous application examples are reviewed for nano spray drying and encapsulation of various drugs in the early stages of product development along with a brief overview of the obtained results and characterization techniques. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. 9 CFR 590.542 - Spray process drying operations.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Spray process drying operations. 590..., Processing, and Facility Requirements § 590.542 Spray process drying operations. (a) The drying room shall be... interrupted. (1) Spray nozzles, orifices, cores, or whizzers shall be cleaned immediately after cessation of...

  20. High-power electronics thermal management with intermittent multijet sprays

    International Nuclear Information System (INIS)

    Panão, Miguel R.O.; Correia, André M.; Moreira, António L.N.

    2012-01-01

    Thermal management plays a crucial role in the development of high-power electronics devices, e.g. in electric vehicles. The greatest energy demands occur during power peaks, implying dynamic thermal losses within the vehicle’s driving cycle. Therefore, the need for devising intelligent thermal management systems able to efficiently respond to these power peaks has become a technological challenge. Experiments have been performed with methanol in order to quantify the maximum heat flux removed by a multijet spray to keep the 4 cm 2 surface temperature stabilized and below the threshold of 125 °C. A multijet atomization strategy consists in producing a spray through the multiple and simultaneous impact of N j cylindrical jets. Moreover, the spray intermittency is expressed through the duty cycle (DC), which depends on the frequency and duration of injection. Results evidence that: i) a shorter time between consecutive injection cycles enables a better distribution of the mass flow rate, resulting in larger heat transfer coefficient values, as well as higher cooling efficiencies; ii) compared with continuous sprays, the analysis evidences that an intermittent spray allows benefiting more from phase-change convection. Moreover, the mass flux is mainly affecting heat transfer rather than differences induced in the spray structure by using different multijet configurations. - Highlights: ► Intermittent spray cooling (ISC) is advantageous for intelligent thermal management. ► Distributing the mass flow rate through ISC improves heat transfer. ► Multijet sprays with increasing number of jets have higher heat transfer rates. ► ISC with multijet sprays benefit more from phase-change than continuous sprays.

  1. Current implications of past DDT indoor spraying in Oman.

    Science.gov (United States)

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Polydisperse effects in jet spray flames

    Science.gov (United States)

    Weinberg, Noam; Greenberg, J. Barry

    2018-01-01

    A laminar jet polydisperse spray diffusion flame is analysed mathematically for the first time using an extension of classical similarity solutions for gaseous jet flames. The analysis enables a comparison to be drawn between conditions for flame stability or flame blow-out for purely gaseous flames and for spray flames. It is found that, in contrast to the Schmidt number criteria relevant to gas flames, droplet size and initial spray polydispersity play a critical role in determining potential flame scenarios. Some qualitative agreement for lift-off height is found when comparing predictions of the theory and sparse independent experimental evidence from the literature.

  3. Spray deposition using impulse atomization technique

    International Nuclear Information System (INIS)

    Ellendt, N.; Schmidt, R.; Knabe, J.; Henein, H.; Uhlenwinkel, V.

    2004-01-01

    A novel technique, impulse atomization, has been used for spray deposition. This single fluid atomization technique leads to different spray characteristics and impact conditions of the droplets compared to gas atomization technique which is the common technique used for spray deposition. Deposition experiments with a Cu-6Sn alloy were conducted to evaluate the appropriateness of impulse atomization to produce dense material. Based on these experiments, a model has been developed to simulate the thermal history and the local solidification rates of the deposited material. A numerical study shows how different cooling conditions affect the solidification rate of the material

  4. Spray drying for processing of nanomaterials

    International Nuclear Information System (INIS)

    Lindeloev, Jesper Saederup; Wahlberg, Michael

    2009-01-01

    Consolidation of nano-particles into micron-sized granules reduces the potential risks associated with handling nano-powders in dry form. Spray drying is a one step granulation technique which can be designed for safe production of free flowing low dusty granules from suspensions of nano-particles. Spray dried granules are well suited for subsequent processing into final products where the superior properties given by the nano-particles are retained. A spray drier with bag filters inside the drying chamber and recycling of drying gas combined with containment valves are proposed as a safe process for granulation of potential hazardous nano-particles.

  5. Containment atmosphere response to external sprays

    International Nuclear Information System (INIS)

    Green, J.; Almenas, K.

    1995-01-01

    The application of external sprays to a containment steel shell can be an effective energy removal method and has been proposed in the passive AP-600 design. Reduction of the steel shell temperature in contact with the containment atmosphere enhances both heat and mass transfer driving forces. Large scale experimental data in this area is scarce, therefore the measurements obtained from the E series tests conducted at the German HDR facility deserve special attention. These long term tests simulated various severe accident conditions, including external spraying of the hemispherical steel shell. This investigation focuses upon the integral response of the HDR containment atmosphere during spray periods and upon methods by which lumped parameter system codes, like CONTAIN, model the underlying condensation phenomena. Increases in spray water flowrates above a minimum value were ineffective at improving containment pressure reduction since the limiting resistance for energy transfer lies in the noncondensable-vapor boundary layer at the inner condensing surface. The spray created an unstable condition by cooling the upper layers of a heated atmosphere and thus inducing global natural circulation flows in the facility and subsequently, abrupt changes in lighter-than-air noncondensable (J 2 /He) concentrations. Modeling results using the CONTAIN code are outlined and code limitations are delineated

  6. Containment atmosphere response to external sprays

    Energy Technology Data Exchange (ETDEWEB)

    Green, J.; Almenas, K. [Univ. of Maryland, College Park, MD (United States)

    1995-09-01

    The application of external sprays to a containment steel shell can be an effective energy removal method and has been proposed in the passive AP-600 design. Reduction of the steel shell temperature in contact with the containment atmosphere enhances both heat and mass transfer driving forces. Large scale experimental data in this area is scarce, therefore the measurements obtained from the E series tests conducted at the German HDR facility deserve special attention. These long term tests simulated various severe accident conditions, including external spraying of the hemispherical steel shell. This investigation focuses upon the integral response of the HDR containment atmosphere during spray periods and upon methods by which lumped parameter system codes, like CONTAIN, model the underlying condensation phenomena. Increases in spray water flowrates above a minimum value were ineffective at improving containment pressure reduction since the limiting resistance for energy transfer lies in the noncondensable-vapor boundary layer at the inner condensing surface. The spray created an unstable condition by cooling the upper layers of a heated atmosphere and thus inducing global natural circulation flows in the facility and subsequently, abrupt changes in lighter-than-air noncondensable (J{sub 2}/He) concentrations. Modeling results using the CONTAIN code are outlined and code limitations are delineated.

  7. A Grey-Box Model for Spray Drying Plants

    DEFF Research Database (Denmark)

    Petersen, Lars Norbert; Poulsen, Niels Kjølstad; Niemann, Hans Henrik

    2013-01-01

    Multi-stage spray drying is an important and widely used unit operation in the production of food powders. In this paper we develop and present a dynamic model of the complete drying process in a multi-stage spray dryer. The dryer is divided into three stages: The spray stage and two fluid bed...

  8. Numerical Modeling of Diesel Spray Formation and Combustion

    NARCIS (Netherlands)

    Bekdemir, C.; Somers, L.M.T.; Goey, de L.P.H.

    2009-01-01

    A study is presented on the modeling of fuel sprays in diesel engines. The objective of this study is in the first place to accurately and efficiently model non-reacting diesel spray formation, and secondly to include ignition and combustion. For that an efficient 1D Euler-Euler spray model [21] is

  9. Inhalational and dermal exposures during spray application of biocides.

    Science.gov (United States)

    Berger-Preiss, Edith; Boehncke, Andrea; Könnecker, Gustav; Mangelsdorf, Inge; Holthenrich, Dagmar; Koch, Wolfgang

    2005-01-01

    Data on inhalational and potential dermal exposures during spray application of liquid biocidal products were generated. On the one hand, model experiments with different spraying devices using fluorescent tracers were carried out to investigate the influence of parameters relevant to the exposure (e.g. spraying equipment, nozzle size, direction of application). On the other hand, measurements were performed at selected workplaces (during disinfection operations in food and feed areas; pest control operations for private, public and veterinary hygiene; wood protection and antifouling applications) after application of biocidal products such as Empire 20, Responsar SC, Omexan-forte, Actellic, Perma-forte; Fendona SC, Pyrethrum mist; CBM 8, Aldekol Des 03, TAD CID, Basileum, Basilit. The measurements taken in the model rooms demonstrated dependence of the inhalation exposure on the type of spraying device used, in the following order: "spraying with low pressure" < "airless spraying" < "fogging" indicating that the particle diameter of the released spray droplets is the most important parameter. In addition inhalation exposure was lowest when the spraying direction was downward. Also for the potential dermal exposure, the spraying direction was of particular importance: overhead spraying caused the highest contamination of body surfaces. The data of inhalational and potential dermal exposures gained through workplace measurements showed considerable variation. During spraying procedures with low-pressure equipments, dose rates of active substances inhaled by the operators ranged from 7 to 230 microg active substance (a.s.)/h. An increase in inhaled dose rates (6-33 mg a.s./h) was observed after use of high application volumes/time unit during wood protection applications indoors. Spraying in the veterinary sector using medium-pressure sprayers led to inhaled dose rates between 2 and 24mga.s./h. The highest inhaled dose rates were measured during fogging (114 mg a

  10. Automated Plasma Spray (APS) process feasibility study: Plasma spray process development and evaluation

    Science.gov (United States)

    Fetheroff, C. W.; Derkacs, T.; Matay, I. M.

    1979-01-01

    An automated plasma spray (APS) process was developed to apply two layer (NiCrAlY and ZrO2-12Y2O3) thermal-barrier coatings to aircraft gas turbine engine blade airfoils. The APS process hardware consists of four subsystems: a mechanical blade positioner incorporating two interlaced six-degree-of-freedom assemblies; a noncoherent optical metrology subsystem; a microprocessor-based adaptive system controller; and commercial plasma spray equipment. Over fifty JT9D first stage turbine blades specimens were coated with the APS process in preliminary checkout and evaluation studies. The best of the preliminary specimens achieved an overall coating thickness uniformity of + or - 53 micrometers, much better than is achievable manually. Factors limiting this performance were identified and process modifications were initiated accordingly. Comparative evaluations of coating thickness uniformity for manually sprayed and APS coated specimens were initiated. One of the preliminary evaluation specimens was subjected to a torch test and metallographic evaluation.

  11. Plasma spraying of beryllium and beryllium-aluminum-silver alloys

    International Nuclear Information System (INIS)

    Castro, R.G.; Stanek, P.W.; Elliott, K.E.; Jacobson, L.A.

    1994-01-01

    A preliminary investigation on plasma-spraying of beryllium and a beryllium-aluminum-4% silver alloy was done at the Los Alamos National Laboratory's Beryllium Atomization and Thermal Spray Facility (BATSF). Spherical Be and Be-Al-4%Ag powders, which were produced by centrifugal atomization, were used as feedstock material for plasma-spraying. The spherical morphology of the powders allowed for better feeding of fine (<38 μm) powders into the plasma-spray torch. The difference in the as-deposited densities and deposit efficiencies of the two plasma-sprayed powders will be discussed along with the effect of processing parameters on the as-deposited microstructure of the Be-Al-4%Ag. This investigation represents ongoing research to develop and characterize plasma-spraying of beryllium and beryllium-aluminum alloys for magnetic fusion and aerospace applications

  12. Plasma spraying of beryllium and beryllium-aluminum-silver alloys

    International Nuclear Information System (INIS)

    Castro, R.G.; Stanek, P.W.; Elliott, K.E.; Jacobson, L.A.

    1993-01-01

    A preliminary investigation on plasma-spraying of beryllium and a beryllium-aluminum 4% silver alloy was done at the Los Alamos National Laboratory's Beryllium Atomization and Thermal Spray Facility (BATSF). Spherical Be and Be-Al-4%Ag powders, which were produced by centrifugal atomization, were used as feedstock material for plasma-spraying. The spherical morphology of the powders allowed for better feeding of fine (<38 μm) powders into the plasma-spray torch. The difference in the as-deposited densities and deposit efficiencies of the two plasma-sprayed powders will be discussed along with the effect of processing parameters on the as-deposited microstructure of the Be-Al-4%Ag. This investigation represents ongoing research to develop and characterize plasma-spraying of beryllium and beryllium-aluminum alloys for magnetic fusion and aerospace applications

  13. Unit thermal performance of atmospheric spray cooling systems

    International Nuclear Information System (INIS)

    Porter, R.W.; Jain, M.; Chaturvedi, S.K.

    1980-01-01

    Thermal performance of an open atmospheric spray pond or canal depends on the direct-contact evaporative cooling of an individual spray unit (spray nozzle or module) and the interference caused by local heating and humidification. Droplet parameters may be combined into a dimensionless group, number of transfer units (NTU) or equivalent, whereas large-scale air-vapor dynamics determine interference through the local wet-bulb temperature. Quantity NTU were implied from field experiments for a floating module used in steam-condenser spray canals. Previous data were available for a fixed-pipe nozzle assembly used in spray ponds. Quantity NTU were also predicted using the Ranz-Marshall correlations with the Sauter-mean diameter used as the characteristic length. Good agreement with experiments was shown for diameters of 1--1.1 cm (module) and 1.9 mm

  14. Plasma spray technology process parameters and applications

    International Nuclear Information System (INIS)

    Sreekumar, K.P.; Karthikeyan, J.; Ananthapadmanabhan, P.V.; Venkatramani, N.; Chatterjee, U.K.

    1991-01-01

    The current trend in the structural design philosophy is based on the use of substrate with the necessary mechanical properties and a thin coating to exhibit surface properties. Plasma spray process is a versatile surface coating technique which finds extensive application in meeting advance technologies. This report describes the plasma spray technique and its use in developing coatings for various applications. The spray system is desribed in detail including the different variables such as power input to the torch, gas flow rate, powder properties, powder injection, etc. and their interrelation in deciding the quality of the coating. A brief write-up on the various plasma spray coatings developed for different applications is also included. (author). 15 refs., 15 figs., 2 tabs

  15. Uniform-droplet spray forming

    Energy Technology Data Exchange (ETDEWEB)

    Blue, C.A.; Sikka, V.K. [Oak Ridge National Lab., TN (United States); Chun, Jung-Hoon [Massachusetts Institute of Technology, Cambridge, MA (United States); Ando, T. [Tufts Univ., Medford, MA (United States)

    1997-04-01

    The uniform-droplet process is a new method of liquid-metal atomization that results in single droplets that can be used to produce mono-size powders or sprayed-on to substrates to produce near-net shapes with tailored microstructure. The mono-sized powder-production capability of the uniform-droplet process also has the potential of permitting engineered powder blends to produce components of controlled porosity. Metal and alloy powders are commercially produced by at least three different methods: gas atomization, water atomization, and rotating disk. All three methods produce powders of a broad range in size with a very small yield of fine powders with single-sized droplets that can be used to produce mono-size powders or sprayed-on substrates to produce near-net shapes with tailored microstructures. The economical analysis has shown the process to have the potential of reducing capital cost by 50% and operating cost by 37.5% when applied to powder making. For the spray-forming process, a 25% savings is expected in both the capital and operating costs. The project is jointly carried out at Massachusetts Institute of Technology (MIT), Tuffs University, and Oak Ridge National Laboratory (ORNL). Preliminary interactions with both finished parts and powder producers have shown a strong interest in the uniform-droplet process. Systematic studies are being conducted to optimize the process parameters, understand the solidification of droplets and spray deposits, and develop a uniform-droplet-system (UDS) apparatus appropriate for processing engineering alloys.

  16. Emulsions from Aerosol Sprays

    Science.gov (United States)

    Hengelmolen; Vincent; Hassall

    1997-12-01

    An electrostatic emulsification apparatus has been designed for the purpose of studying diffusion from oil droplets which have a mean size in the range of approximately 1.5-3.5 &mgr;m, with standard deviations of 40-50%. The emulsification technique involves the collection of a spray of electrically charged oil droplets onto a rotating water film which is sustained from a reservoir. In this way, emulsions with volume fractions of approximately 10(-3) are produced within several minutes at oil flow rates of around 10(-2) ml min-1. Phase-Doppler anemometry (PDA) was used to assess droplet size distributions for the sprays and emulsions. Results show that the mean emulsion droplet size was smaller than the mean spray droplet size by several orders of magnitude. At flow rates around 10(-2) ml min-1, the spray droplet size distribution was little affected by the applied potential between about -4.20 and -4.65 kV (mean droplet size between approximately 7.6 and 7.8 &mgr;m, with standard deviations of approximately 20%), whereas the mean droplet size of the corresponding emulsion decreased more rapidly with applied potential. Above an applied potential of approximately -4.30 kV, which corresponded to an emulsion droplet size below approximately 2 &mgr;m, the measured volume fraction of the emulsion decreased with respect to the volume fraction as calculated on the basis of total amount of injected oil. Copyright 1997 Academic Press. Copyright 1997Academic Press

  17. Center for Cold Spray Research and Development

    Data.gov (United States)

    Federal Laboratory Consortium — This is the only DoD facility capable of cold spray research and development, production, and field-repair. It features three stationary cold spray systems used for...

  18. User friendliness, efficiency & spray quality of stirrup pumps versus hand compression pumps for indoor residual spraying.

    Science.gov (United States)

    Kumar, Vijay; Kesari, Shreekant; Chowdhury, Rajib; Kumar, Sanjiv; Sinha, Gunjan; Hussain, Saddam; Huda, M Mamun; Kroeger, Axel; Das, Pradeep

    2013-01-01

    Indoor residual spraying (IRS) is a proven tool to reduce visceral leishmaniasis vectors in endemic villages. In India IRS is being done with stirrup pumps, whereas Nepal, Bangladesh, and other countries use compression pumps. The present study was conducted with the objectives to compare the efficiency, cost and user friendliness of stirrup and compression pumps. The study was carried out in Gorigawan village of the Vaishali district in north Bihar and included a total population of 3259 inhabitants in 605 households. Spraying with 50 per cent DDT was done by two teams with 6 persons per team under the supervision of investigators over 5 days with each type of pump (10 days in total using 2 stirrup pumps and 3 compression pumps) by the same sprayers in an alternate way. The spraying technique was observed using an observation check list, the number of houses and room surfaces sprayed was recorded and an interview with sprayers on their satisfaction with the two types of pumps was conducted. On average, 65 houses were covered per day with the compression pump and 56 houses were covered with the stirrup pump. The surface area sprayed per squad per day was higher for the compression pump (4636 m²) than for the stirrup pump (4102 m²). Observation showed that it was easy to maintain the spray swath with the compression pump but very difficult with the stirrup pump. The wastage of insecticide suspension was negligible for the compression pump but high for the stirrup pump. The compression pump was found to be more user friendly due to its lower weight, easier to operate, lower operation cost, higher safety and better efficiency in terms of discharge rate and higher area coverage than the stirrup pump.

  19. Investigation and control of dc arc jet instabilities to obtain a self-sustained pulsed laminar arc jet

    International Nuclear Information System (INIS)

    Krowka, J; Rat, V; Coudert, J F

    2013-01-01

    The uncontrolled arc plasma instabilities in suspension plasma spraying or solution precursor plasma spraying cause non-homogeneous plasma treatments of material during their flight and also on coatings during their formation. This paper shows that the arc motion in dc plasma torches mainly originates in two main modes of oscillation (Helmholtz and restrike modes). The emphasis is put on the restrike mode in which the time component is extracted after building up and applying a numerical filter to raw arc voltage signals. The dependence of re-arcing events on experimental parameters is analysed in the frame of a phenomenological restrike model. It is shown that when the restrike frequency reaches the Helmholtz one, both modes are locked together and a pulsed arc jet is generated. (paper)

  20. Effects of repeated insecticide pulses on macroinvertebrate drift in indoor stream mesocosms.

    Science.gov (United States)

    Berghahn, Rüdiger; Mohr, Silvia; Hübner, Verena; Schmiediche, Ronny; Schmiedling, Ina; Svetich-Will, Erkki; Schmidt, Ralf

    2012-10-15

    Pesticide contaminations via run-off or spray drift have been reported to result in the mass drift of macroinvertebrates as well as causing structural and functional changes of the corresponding stream sections. However, pesticide pulses in the field are associated with sudden increases in flow velocity, water turbidity, and changes in water temperature, which can also induce drift. Only through replicated community testing under highly controlled conditions can these effects be disentangled. In a stream mesocosm study, 12-h pulses of 12 μg/L imidacloprid were set three times at weekly intervals and are considered a "pulse series". Two pulse series of this neonicotinoid insecticide were run in both spring and summer with 4 treatment and 4 control stream mesocosms used in each pulse series. Prior to the start of the mesocosm experiment, both pulse concentration and duration had been screened for drift responses in larval Baetidae, Chironomidae and adult Gammarus roeseli in laboratory experiments. In the subsequent mesocosm study, each pulse caused a pronounced increase in the drift of insect larvae and gammarids. The drift response was taxon-specific, which was related to preferred habitat and exposure to other stressors like current velocity, in addition to imidacloprid sensitivity. Activity measurements employing a Multispecies Freshwater Biomonitor(®) revealed that in Baetis sp. the diurnal activity pattern became more pronounced even 12h after the pulse though with slightly decreased mean physical activity. Adult G. roeseli showed a drastic pulse by pulse decrease in physical activity which after the 3rd pulse lasted longer than 24h. In conclusion, drift is a sensitive, ecologically relevant endpoint and should be regarded when a specific risk assessment for lotic surface waters is done, e.g. in the context of a spatially explicit risk assessment. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Nanoparticles by spray drying using innovative new technology: the Büchi nano spray dryer B-90.

    Science.gov (United States)

    Li, Xiang; Anton, Nicolas; Arpagaus, Cordin; Belleteix, Fabrice; Vandamme, Thierry F

    2010-10-15

    Spray drying technology is widely known and used to transform liquids (solutions, emulsions, suspension, slurries, pastes or even melts) into solid powders. Its main applications are found in the food, chemical and materials industries to enhance ingredient conservation, particle properties, powder handling and storage etc. However, spray drying can also be used for specific applications in the formulation of pharmaceuticals for drug delivery (e.g. particles for pulmonary delivery). Büchi is a reference in the development of spray drying technology, notably for laboratory scale devices. This study presents the Nano Spray Dryer B-90, a revolutionary new sprayer developed by Büchi, use of which can lower the size of the produced dried particles by an order of magnitude attaining submicron sizes. In this paper, results are presented with a panel of five representative polymeric wall materials (arabic gum, whey protein, polyvinyl alcohol, modified starch, and maltodextrin) and the potentials to encapsulate nano-emulsions, or to formulate nano-crystals (e.g. from furosemide) are also shown. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. [Research about effect of spray drying conditions on hygroscopicity of spray dry powder of gubi compound's water extract and its mechanism].

    Science.gov (United States)

    Zong, Jie; Shao, Qi; Zhang, Hong-Qing; Pan, Yong-Lan; Zhu, Hua-Xu; Guo, Li-Wei

    2014-02-01

    To investigate moisture content and hygroscopicity of spray dry powder of Gubi compound's water extract obtained at different spray drying conditions and laying a foundation for spray drying process of Chinese herbal compound preparation. In the paper, on the basis of single-factor experiments, the author choose inlet temperature, liquid density, feed rate, air flow rate as investigated factors. The experimental absorption rate-time curve and scanning electron microscopy results showed that under different spray drying conditions the spray-dried powders have different morphology and different adsorption process. At different spray-dried conditions, the morphology and water content of the powder is different, these differences lead to differences in the adsorption process, at the appropriate inlet temperature and feed rate with a higher sample density and lower air flow rate, in the experimental system the optimum conditions is inlet temperature of 150 degrees C, feed density of 1.05 g x mL(-1), feed rate of 20 mL x min(-1) air flow rate of 30 m3 x h(-1).

  3. In-hospital outcome of acute myocardial infarction in correlation with 'thrombolysis in myocardial infarction' risk score

    International Nuclear Information System (INIS)

    Masood, A.; Naqvi, M.A.; Jafar, S.S.

    2009-01-01

    Effective risk stratification is integral to management of acute coronary syndromes (ACS). The Thrombolysis in Myocardial Infarction (TIMI) risk score for ST-segment elevation myocardial infarction (STEMI) is a simple integer score based on 8 high-risk parameters that can be used at the bedside for risk stratification of patients at presentation with STEMI. To evaluate the prognostic significance of TIMI risk score in a local population group of acute STEMI. The study included 160 cases of STEMI eligible for thrombolysis. TIMI risk score was calculated for each case at the time of presentation and were then followed during their hospital stay for the occurrence of electrical and mechanical complications as well as mortality. The patients were divided into three risk groups, namely 'low risk', 'moderate-risk' and 'high-risk' based on their TIMI scores (0-4 low-risk, 5-8 moderate-risk, 9-14 high risk). The frequencies of complications and deaths were compared among the three risk groups. Post MI arrhythmias were noted in 2.2%, 16% and 50%; cardiogenic shock in 6.7%, 16% and 60%; pulmonary edema in 6.7%, 20% and 80%; mechanical complications of MI in 0%, 8% and 30%; death in 4.4%, 8%, and 60% of patients belonging to low-risk, moderate-risk and high-risk groups respectively. Frequency of complications and death correlated well with TIMI risk score (p=0.001). TIMI risk score correlates well with the frequency of electrical or mechanical complications and death after STEMI. (author)

  4. Spray pyrolysis process for preparing superconductive films

    International Nuclear Information System (INIS)

    Hsu, H.M.; Yee, I.Y.

    1991-01-01

    This paper describes a spray pyrolysis method for preparing thin superconductive film. It comprises: preparing a spray pyrolysis solution comprising Bi,Sr,Ca and Cu metals in a solvent; heating a substrate to a first temperature; spraying the solution onto the heated substrate to form a film thereon; heating the film and substrate to a second temperature of about 700 degrees-825 degrees C, the second temperature being higher than the first temperature; heating the film and substrate to a third temperature of about 870 degrees-890 degrees C to melt the film; once the film and substrate reach the third temperature, further heat treating the film and substrate; cooling the film and substrate to ambient temperature. This patent also describes a spray pyrolysis method for preparing thin superconductive films. It comprises: preparing a spray pyrolysis solution comprising Bi, Ca and Cu metals and fluxing agent in a solvent; heating a substrate to a first temperature; spraying the solution onto the heated substrate to form a film thereon; heating the film and substrate to a second temperature about 700 degrees-825 degrees C, the second temperature being higher than the first temperature; heating the film and substrate at a third temperature about 840 degrees-860 degrees C; and cooling the film and substrate to ambient temperature

  5. Influence of Cold-Sprayed, Warm-Sprayed, and Plasma-Sprayed Layers Deposition on Fatigue Properties of Steel Specimens

    Czech Academy of Sciences Publication Activity Database

    Čížek, J.; Matejková, M.; Dlouhý, I.; Šiška, Filip; Kay, C.M.; Karthikeyan, J.; Kuroda, S.; Kovařík, O.; Siegl, J.; Loke, K.; Khor, K.A.

    2015-01-01

    Roč. 24, č. 5 (2015), s. 758-768 ISSN 1059-9630 Institutional support: RVO:68081723 Keywords : Cold spray * Fatigue * Grit-blast Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.568, year: 2015

  6. Dynamic complexities in a pest control model with birth pulse and harvesting

    International Nuclear Information System (INIS)

    Goel, A.; Gakkhar, S.

    2016-01-01

    In this paper, an impulsive model is discussed for an integrated pest management approach comprising of chemical and mechanical controls. The pesticides and harvesting are used to control the stage-structured pest population. The mature pest give birth to immature pest in pulses at regular intervals. The pest is controlled by spraying chemical pesticides affecting immature as well as mature pest. The harvesting of both immature and mature pest further reduce the pest population. The discrete dynamical system obtained from stroboscopic map is analyzed. The threshold conditions for stability of pest-free state as well as non-trivial period-1 solution is obtained. The effect of pesticide spray timing and harvesting on immature as well as mature pest are shown. Finally, by numerical simulation with MATLAB, the dynamical behaviors of the model is found to be complex. Above the threshold level there is a characteristic sequence of bifurcations leading to chaotic dynamics. Route to chaos is found to be period-doubling. Period halving bifurcations are also observed.

  7. Dynamic complexities in a pest control model with birth pulse and harvesting

    Energy Technology Data Exchange (ETDEWEB)

    Goel, A., E-mail: goelanju23@gmail.com; Gakkhar, S., E-mail: sungkfma@iitr.ernet.in [Department of Mathematics, Indian Institute of Technology, Roorkee, Uttarakhand 247667 (India)

    2016-04-06

    In this paper, an impulsive model is discussed for an integrated pest management approach comprising of chemical and mechanical controls. The pesticides and harvesting are used to control the stage-structured pest population. The mature pest give birth to immature pest in pulses at regular intervals. The pest is controlled by spraying chemical pesticides affecting immature as well as mature pest. The harvesting of both immature and mature pest further reduce the pest population. The discrete dynamical system obtained from stroboscopic map is analyzed. The threshold conditions for stability of pest-free state as well as non-trivial period-1 solution is obtained. The effect of pesticide spray timing and harvesting on immature as well as mature pest are shown. Finally, by numerical simulation with MATLAB, the dynamical behaviors of the model is found to be complex. Above the threshold level there is a characteristic sequence of bifurcations leading to chaotic dynamics. Route to chaos is found to be period-doubling. Period halving bifurcations are also observed.

  8. Laser-Based Spatio-Temporal Characterisation of Port Fuel Injection (PFI Sprays

    Directory of Open Access Journals (Sweden)

    C. T. N. Anand

    2010-06-01

    Full Text Available In the present work, detailed laser-based diagnostic experiments were conducted to characterise the spray from low pressure 2-hole and 4-hole Port Fuel Injection (PFI injectors. The main objective of the work included obtaining quantitative information of the spatio-temporal spray structure of such low-pressure gasoline sprays. A novel approach involving a combination of techniques such as Mie scattering, Granulometry, and Laser Sheet Dropsizing (LSD was used to study the spray structure. The droplet sizes, distributions with time, Sauter Mean Diameters (SMD, droplet velocities, cone angles and spray tip penetrations of the sprays from the injectors were determined. The spray from these injectors is found to be ‘pencil like’ and not dispersed as in high pressure sprays. The application of the above mentioned techniques provides two-dimensional SMD contours of the entire spray at different instants of time, with reasonable accuracy.

  9. Simulation of oblique evaporating diesel sprays, and comparison with empirical correlations and simulated straight sprays

    International Nuclear Information System (INIS)

    Chaudhry, I.A.; Mirza, M.R.; Rashid, M.J.

    2010-01-01

    The innovation in software analysis and various available programming facilities have urged the designers at various levels to do indispensable calculations for engine flows. Presently, the 3-D analysis approach is under practice to do simulations for various parameters involving engine operations using various soft wares, 'Fluent' being the trendiest at the moment for CFD modeling. The present work involves CFD modeling of diesel fuel sprays at a specified angle with cylinder axis. Fuel spray modeling includes sub-models for aerodynamic drag, droplet oscillation and distortion, turbulence effects, droplet breakup, evaporation, and droplet collision and coalescence. The data available from existing published work is used to model the fuel spray and the subsequent simulation results are compared to experimental results to test validity of the proposed models. (author)

  10. Aerial electrostatic spray deposition and canopy penetration in cotton

    Science.gov (United States)

    Spray deposition on abaxial and adaxial leaf surfaces along with canopy penetration are essential for insect control and foliage defoliation in cotton production agriculture. Researchers have reported that electrostatically charged sprays have increased spray deposit onto these surfaces under widel...

  11. Calculations for reproducible autologous skin cell-spray grafting.

    Science.gov (United States)

    Esteban-Vives, Roger; Young, Matthew T; Zhu, Toby; Beiriger, Justin; Pekor, Chris; Ziembicki, Jenny; Corcos, Alain; Rubin, Peter; Gerlach, Jörg C

    2016-12-01

    Non-cultured, autologous cell-spray grafting is an alternative to mesh grafting for larger partial- and deep partial-thickness burn wounds. The treatment uses a suspension of isolated cells, from a patient's donor site skin tissue, and cell-spray deposition onto the wound that facilitates re-epithelialization. Existing protocols for therapeutic autologous skin cell isolation and cell-spray grafting have defined the donor site area to treatment area ratio of 1:80, substantially exceeding the coverage of conventional mesh grafting. However, ratios of 1:100 are possible by maximizing the wound treatment area with harvested cells from a given donor site skin tissue according to a given burn area. Although cell isolation methods are very well described in the literature, a rational approach addressing critical aspects of these techniques are of interest in planning clinical study protocols. We considered in an experimental study the cell yield as a function of the donor site skin tissue, the cell density for spray grafting, the liquid spray volume, the sprayed distribution area, and the percentage of surface coverage. The experimental data was then used for the development of constants and mathematical equations to give a rationale for the cell isolation and cell-spray grafting processes and in planning for clinical studies. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  12. Spray drying of liquid radioactive wastes

    International Nuclear Information System (INIS)

    Abrams, R.F.; Monat, J.P.

    1984-01-01

    Full scale performance tests of a Koch spray dryer were conducted on simulated liquid radioactive waste streams. The liquid feeds simulated the solutions that result from radwaste incineration of DAW an ion exchange resins, as well as evaporator bottoms. The integration of the spray dryer into a complete system is discussed

  13. Cold spray NDE for porosity and other process anomalies

    Science.gov (United States)

    Glass, S. W.; Larche, M. R.; Prowant, M. S.; Suter, J. D.; Lareau, J. P.; Jiang, X.; Ross, K. A.

    2018-04-01

    This paper describes a technology review of nondestructive evaluation (NDE) methods that can be applied to cold spray coatings. Cold spray is a process for depositing metal powder at high velocity so that it bonds to the substrate metal without significant heating that would be likely to cause additional residual tensile stresses. Coatings in the range from millimeters to centimeters are possible at relatively high deposition rates. Cold spray coatings that may be used for hydroelectric components that are subject to erosion, corrosion, wear, and cavitation damage are of interest. The topic of cold spray NDE is treated generally, however, but may be considered applicable to virtually any cold spray application except where there are constraints of the hydroelectric component application that bear special consideration. Optical profilometry, eddy current, ultrasound, and hardness tests are shown for one set of good, fair, and poor nickel-chrome (NiCr) on 304 stainless steel (304SS) cold spray samples to demonstrate inspection possibilities. The primary indicator of cold spray quality is the cold spray porosity that is most directly measured with witness-sample destructive examinations (DE)—mostly photo-micrographs. These DE-generated porosity values are correlated with optical profilometry, eddy current, ultrasound, and hardness test NDE methods to infer the porosity and other information of interest. These parameters of interest primarily include: • Porosity primarily caused by improper process conditions (temperature, gas velocity, spray standoff, spray angle, powder size, condition, surface cleanliness, surface oxide, etc.) • Presence/absence of the cold spray coating including possible over-sprayed voids • Coating thicknessOptical profilometry measurements of surface roughness trended with porosity plus, if compared with a reference measurement or reference drawing, would provide information on the coating thickness. Ultrasound could provide similar

  14. No Heat Spray Drying Technology

    Energy Technology Data Exchange (ETDEWEB)

    Beetz, Charles [ZoomEssence, Inc., Hebron, KY (United States)

    2016-06-15

    No Heat Spray Drying Technology. ZoomEssence has developed our Zooming™ spray drying technology that atomizes liquids to powders at ambient temperature. The process of drying a liquid into a powder form has been traditionally achieved by mixing a heated gas with an atomized (sprayed) fluid within a vessel (drying chamber) causing the solvent to evaporate. The predominant spray drying process in use today employs air heated up to 400° Fahrenheit to dry an atomized liquid into a powder. Exposing sensitive, volatile liquid ingredients to high temperature causes molecular degradation that negatively impacts solubility, stability and profile of the powder. In short, heat is detrimental to many liquid ingredients. The completed award focused on several areas in order to advance the prototype dryer to a commercial scale integrated pilot system. Prior to the award, ZoomEssence had developed a prototype ‘no-heat’ dryer that firmly established the feasibility of the Zooming™ process. The award focused on three primary areas to improve the technology: (1) improved ability to formulate emulsions for specific flavor groups and improved understanding of the relationship of emulsion properties to final dry particle properties, (2) a new production atomizer, and (3) a dryer controls system.

  15. Regimes of spray formation in gas-centered swirl coaxial atomizers

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, D.; Kulkarni, V. [Indian Institute of Science, Department of Aerospace Engineering, Bangalore (India)

    2011-09-15

    Spray formation in ambient atmosphere from gas-centered swirl coaxial atomizers is described by carrying out experiments in a spray test facility. The atomizer discharges a circular air jet and an axisymmetric swirling water sheet from its coaxially arranged inner and outer orifices. A high-speed digital imaging system along with a backlight illumination arrangement is employed to record the details of liquid sheet breakup and spray development. Spray regimes exhibiting different sheet breakup mechanisms are identified and their characteristic features presented. The identified spray regimes are wave-assisted sheet breakup, perforated sheet breakup, segmented sheet breakup, and pulsation spray regime. In the regime of wave-assisted sheet breakup, the sheet breakup shows features similar to the breakup of two-dimensional planar air-blasted liquid sheets. At high air-to-liquid momentum ratios, the interaction process between the axisymmetric swirling liquid sheet and the circular air jet develops spray processes which are more specific to the atomizer studied here. The spray exhibits a periodic ejection of liquid masses whose features are dominantly controlled by the central air jet. (orig.)

  16. Holodiscus (K. Koch) Maxim.: ocean-spray

    Science.gov (United States)

    Nancy L. Shaw; Emerenciana G. Hurd; Peter F. Stickney

    2008-01-01

    Holodiscus is a taxonomically complex genus including about 6 species of western North America and northern South America (Hitchcock and others 1961; Ley 1943). The 2 generally recognized North American species (table 1) - creambush ocean-spray and gland ocean-spray - are deciduous, multistemmed shrubs with simple, alternate, deciduous, toothed to shallowly lobed,...

  17. Optimum pulse duration and radiant exposure for vascular laser therapy of dark port-wine skin: a theoretical study

    International Nuclear Information System (INIS)

    Tunnell, James W.; Anvari, Bahman; Wang, Lihong V.

    2003-01-01

    Laser therapy for cutaneous hypervascular malformations such as port-wine stain birthmarks is currently not feasible for dark-skinned individuals. We study the effects of pulse duration, radiant exposure, and cryogen spray cooling (CSC) on the thermal response of skin, using a Monte Carlo based optical-thermal model. Thermal injury to the epidermis decreases with increasing pulse duration during irradiation at a constant radiant exposure; however, maintaining vascular injury requires that the radiant exposure also increase. At short pulse durations, only a minimal increase in radiant exposure is necessary for a therapeutic effect to be achieved because thermal diffusion from the vessels is minimal. However, at longer pulse durations the radiant exposure must be greatly increased. There exists an optimum pulse duration at which minimal damage to the epidermis and significant injury within the targeted vasculature occur. For example, the model predicts optimum pulse durations of approximately 1.5, 6, and 20 ms for vessel diameters of 40, 80, and 120 μm, respectively. Optimization of laser pulse duration and radiant exposure in combination with CSC may offer a means to treat cutaneous lesions in dark-skinned individuals

  18. Autoignition of liquid-fuel sprays

    International Nuclear Information System (INIS)

    Mitzutani, Y.

    1991-01-01

    This paper reports on the published autoignition data of liquid fuel sprays that were extensively reviewed by classifying them into the following three categories; liquid fuels injected into a stagnant hot atmosphere, liquid fuels injected into a hot air stream (vitiated or unvitiated), and droplet cluster ignited behind an incident or reflected shock. Comparison of these data with the counterparts of gaseous fuels and single droplets revealed that it was the ignition process dominated by droplet evaporation whereas it was the one dominated by chemical kinetics. It consisted, depending on the experimental condition, of the data and of the ignition process dominated by the shattering of droplets by an incident shock. In addition, theoretical works on spray autoignition were reviewed, pointing out that they were still far from universally predicting the ignition delays of liquid fuel sprays

  19. The Influence of Spray Parameters on the Characteristics of Hydroxyapatite In-Flight Particles, Splats and Coatings by Micro-plasma Spraying

    Science.gov (United States)

    Liu, Xiao-mei; He, Ding-yong; Wang, Yi-ming; Zhou, Zheng; Wang, Guo-hong; Tan, Zhen; Wang, Zeng-jie

    2018-04-01

    Hydroxyapatite (HA) is one of the most important bioceramic materials used in medical implants. The structure of HA coatings is closely related to their manufacturing process. In the present study, HA coatings were deposited on Ti-6Al-4V substrate by micro-plasma spraying. Results show that three distinct HA coatings could be obtained by changing the spraying power from 0.5 to 1.0 kW and spraying stand-off distance from 60 to 110 mm: (1) high crystallinity (93.3%) coatings with porous structure, (2) high crystallinity coatings (86%) with columnar structure, (3) higher amorphous calcium phosphate (ACP, 50%) coatings with dense structure. The in-flight particles melting state and splat topography was analyzed to better understand the formation mechanism of three distinct HA coatings. Results show that HA coatings sprayed at low spraying power and short stand-off distance exhibit high crystallinity and porosity is attributed to the presence of partially melted particles. High crystallinity HA coatings with (002) crystallographic texture could be deposited due to the complete melting of the in-flight particles and low cooling rate of the disk shape splats under higher spraying power and shorter SOD. However, splashed shape splats with relative high cooling can be provided by increasing SOD, which leads to the formation of ACP.

  20. Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

    International Nuclear Information System (INIS)

    Yang, Shuofei; Liu, Baochen; Ding, Weiwei; He, Changsheng; Wu, Xingjiang; Li, Jieshou

    2015-01-01

    PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement in symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome

  1. Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuofei, E-mail: yangshuofei@gmail.com; Liu, Baochen, E-mail: 306446264@qq.com; Ding, Weiwei, E-mail: dingwei-nju@hotmail.com; He, Changsheng, E-mail: hechsh@163.com; Wu, Xingjiang, E-mail: wuxingjiang@sohu.com; Li, Jieshou, E-mail: lijieshou2013@sohu.com [Research Institute of General Surgery, Jinling Hospital, Medical School of Nanjing University (China)

    2015-02-15

    PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement in symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome.

  2. Efficient spray-coated colloidal quantum dot solar cells

    KAUST Repository

    Kramer, Illan J.

    2014-11-10

    (Figure Presented). A colloidal quantum dot solar cell is fabricated by spray-coating under ambient conditions. By developing a room-temperature spray-coating technique and implementing a fully automated process with near monolayer control - an approach termed as sprayLD - an electronic defect is eliminated resulting in solar cell performance and statistical distribution superior to prior batch-processed methods along with a hero performance of 8.1%.

  3. Efficient spray-coated colloidal quantum dot solar cells

    KAUST Repository

    Kramer, Illan J.; Minor, James C.; Moreno-Bautista, Gabriel; Rollny, Lisa R.; Kanjanaboos, Pongsakorn; Kopilovic, Damir; Thon, Susanna; Carey, Graham H.; Chou, Kang Wei; Zhitomirsky, David; Amassian, Aram; Sargent, E. H.

    2014-01-01

    (Figure Presented). A colloidal quantum dot solar cell is fabricated by spray-coating under ambient conditions. By developing a room-temperature spray-coating technique and implementing a fully automated process with near monolayer control - an approach termed as sprayLD - an electronic defect is eliminated resulting in solar cell performance and statistical distribution superior to prior batch-processed methods along with a hero performance of 8.1%.

  4. Shear Strengthening of RC Beams Using Sprayed Glass Fiber Reinforced Polymer

    Directory of Open Access Journals (Sweden)

    Sayed Mohamad Soleimani

    2012-01-01

    Full Text Available The effectiveness of externally bonded sprayed glass fiber reinforced polymer (Sprayed GFRP in shear strengthening of RC beams under quasi-static loading is investigated. Different techniques were utilized to enhance the bond between concrete and Sprayed GFRP, involving the use of through bolts and nuts paired with concrete surface preparation through sandblasting and through the use of a pneumatic chisel prior to Sprayed GFRP application. It was found that roughening the concrete surface using a pneumatic chisel and using through bolts and nuts were the most effective techniques. Also, Sprayed GFRP applied on 3 sides (U-shaped was found to be more effective than 2-sided Sprayed GFRP in shear strengthening. Sprayed GFRP increased the shear load-carrying capacity and energy absorption capacities of RC beams. It was found that the load-carrying capacity of strengthened RC beams was related to an effective strain of applied Sprayed GFRP. This strain was related to Sprayed GFRP configuration and the technique used to enhance the concrete-FRP bond. Finally, an equation was proposed to calculate the contribution of Sprayed GFRP in the shear strength of an RC beam.

  5. Spray drying of bead resins: feasibility tests

    International Nuclear Information System (INIS)

    Gay, R.L.; Grantham, L.F.; Jones, L.J.

    1984-01-01

    Rockwell International has developed a volume reduction system for low-level reactor wastes based on drying the wastes in a heated-air spray dryer. The drying of slurries of sodium sulfate, boric acid, and powdered ion exchange resins was demonstrated in previous tests. The drying of bead ion exchange resins can be especially difficult due to the relatively large size of bead resins (about 500 to 800 microns) and their natural affinity for water. This water becomes part of the pore structure of the resins and normally comprises 50 t 60 wt % of the resin weight. A 76-cm-diameter spray dryer was used for feasibility tests of spray drying of cation and anion bead resins. These resins were fed to the dryer in the as-received form (similar to dewatered resins) and as slurries. A dry, free-flowing product was produced in all the tests. The volume of the spray-dried product was one-half to one-third the volume of the as-received material. An economic analysis was made of the potential cost savings that can be achieved using the Rockwel spray dryer system. In-plant costs, transportation costs, and burial costs of spray-dried resins were compared to similar costs for disposal of dewatered resins. A typical utility producing 170 m 3 (6,000 ft 3 ) per year of dewatered resins can save $600,000 to $700,000 per year using this volume reduction system

  6. Quantitative Assessment of Spray Deposition with Water-Sensitive Paper

    Science.gov (United States)

    Spray droplets, discharged from the lower six nozzles of an airblast sprayer, were sampled on pairs of absorbent filter and water-sensitive papers at nine distances from sprayer. Spray deposition on filter targets were measured by fluorometry and spray distribution on WSP targets were assessed by t...

  7. X-ray vision of fuel sprays

    International Nuclear Information System (INIS)

    Wang, J.

    2005-01-01

    With brilliant synchrotron X-ray sources, microsecond time-resolved synchrotron X-ray radiography and tomography have been used to elucidate the detailed three-dimensional structure and dynamics of high-pressure high-speed fuel sprays in the near-nozzle region. The measurement allows quantitative determination of the fuel distribution in the optically impenetrable region owing to the multiple scattering of visible light by small atomized fuel droplets surrounding the jet. X-radiographs of the jet-induced shock waves prove that the fuel jets become supersonic under appropriate injection conditions and that the quantitative analysis of the thermodynamic properties of the shock waves can also be derived from the most direct measurement. In other situations where extremely axial-asymmetric sprays are encountered, mass deconvolution and cross-sectional fuel distribution models can be computed based on the monochromatic and time-resolved X-radiographic images collected from various rotational orientations of the sprays. Such quantitative analysis reveals the never-before-reported characteristics and most detailed near-nozzle mass distribution of highly transient fuel sprays

  8. A comparison between spray drying and spray freeze drying to produce an influenza subunit vaccine powder for inhalation

    NARCIS (Netherlands)

    Saluja, V.; Amorij, J-P.; Kapteyn, J. C.; de Boer, A. H.; Frijlink, H. W.; Hinrichs, W. L. J.

    2010-01-01

    The aim of this study was to investigate two different processes to produce a stable influenza subunit vaccine powder for pulmonary immunization i.e. spray drying (SD) and spray freeze drying (SFD). The formulations were analyzed by proteolytic assay, single radial immunodiffusion assay (SRID),

  9. Spot Spraying Reduces Herbicide Concentrations in Runoff.

    Science.gov (United States)

    Melland, Alice R; Silburn, D Mark; McHugh, Allen D; Fillols, Emilie; Rojas-Ponce, Samuel; Baillie, Craig; Lewis, Stephen

    2016-05-25

    Rainfall simulator trials were conducted on sugar cane paddocks across dry-tropical and subtropical Queensland, Australia, to examine the potential for spot spraying to reduce herbicide losses in runoff. Recommended rates of the herbicides glyphosate, 2,4-D, fluoroxypyr, atrazine, and diuron were sprayed onto 0, 20, 40, 50, 70, or 100% of the area of runoff plots. Simulated rainfall was applied 2 days after spraying to induce runoff at one plant cane and three ratoon crop sites. Over 50% of all herbicides were transported in the dissolved phase of runoff, regardless of the herbicide's sediment-water partition coefficient. For most sites and herbicides, runoff herbicide concentrations decreased with decreasing spray coverage and with decreasing herbicide load in the soil and cane residues. Importantly, sites with higher infiltration prior to runoff and lower total runoff had lower runoff herbicide concentrations.

  10. Spray drying of fruit and vegetable juices--a review.

    Science.gov (United States)

    Verma, Anjali; Singh, Satya Vir

    2015-01-01

    The main cause of spray drying is to increase the shelf life and easy handling of juices. In the present paper, the studies carried out so far on spray drying of various fruits and vegetables are reported. The major fruit juices dried are mango, banana, orange, guava, bayberry, watermelon, pineapple, etc. However, study on vegetable juices is limited. In spray drying, the major optimized parameters are inlet air temperature, relative humidity of air, outlet air temperature, and atomizer speed that are given for a particular study. The juices in spray drying require addition of drying agents that include matlodextrin, liquid glucose, etc. The drying agents are added to increase the glass transition temperature. Different approaches for spray dryer design have also been discussed in the present work.

  11. Experimental study of spray characteristics of biodiesel derived from waste cooking oil

    International Nuclear Information System (INIS)

    Mohan, Balaji; Yang, Wenming; Tay, Kun Lin; Yu, Wenbin

    2014-01-01

    Highlights: • B20 and diesel exhibit similar spray tip penetration and angle. • Change in orientation of spray shapes observed with different fuels. • B100 shows poor air fuel mixing compared to B20 and diesel. • Diesel shows higher equivalence ratio compared to B20 and B100. - Abstract: In this study, the fuel spray characteristics and air-fuel mixing process of waste cooking oil biodiesel (B100) and its blend with diesel (B20) were investigated and compared with diesel fuel. Spray characteristics such as spray tip penetration, spray angle, spray velocity and spray morphology were investigated under high injection and ambient pressure conditions using a constant volume spray chamber. The air-fuel mixing process was analysed using empirical relations like fuel volume, mass of air entrained within the spray and equivalence ratio. The results shows that B100 has higher spray tip penetration and velocity but narrow spray angles due to high viscosity and large momentum possessed by B100 compared to B20 and diesel fuels. The deviation in spray tip penetration reduces under high ambient pressure. The spray angle shows no change under various injection pressures; however it increases significantly under high ambient pressure. The spray shape is affected by the cavitation inside the injector nozzle holes. The fuel volume and amount of air entrainment within the spray showed that B100 exhibits poor air-fuel mixing compared to B20 and diesel fuels. Nevertheless, the equivalence ratio along the axial direction of spray reveals that the B100 has lean equivalence ratio compared to B20 and diesel fuel due to the presence of inherent oxygen content in its structure. A numerical simulation was conducted using new hybrid spray model implemented in KIVA4 and found that the results obtained from the simulation were in good agreement with the empirical results calculated from the experiments

  12. Residual stress determination in thermally sprayed metallic deposits by neutron diffraction

    International Nuclear Information System (INIS)

    Keller, Thomas; Margadant, Nikolaus; Pirling, Thilo; Riegert-Escribano, Maria J.; Wagner, Werner

    2004-01-01

    Neutron diffraction was used to obtain spatially resolved strain and stress profiles in thermally sprayed metallic 'NiCrAlY' deposits (chemical composition 67 wt.% Ni, 22 wt.% Cr, 10 wt.% Al, 1 wt.% Y) and the underlying steel substrates. Samples of four different spray techniques were analyzed: atmospheric and water stabilized plasma spraying (APS and WSP), flame spraying (FS) and wire arc spraying (WAS). The results are quantitatively compared with the average in-plane residual stress determined by complementary bending tests and the hole drilling technique. While the stress profiles from the surface to the interface in the deposits are similar for all investigated spray techniques, their absolute values and gradients vary strongly. This is attributed to different quenching stresses from the impinging particles, different thermal histories the deposit/substrate systems undergo during the spraying and subsequent cooling, and also to different coating properties. In the water stabilized plasma sprayed and the wire arc sprayed deposits, a gradient in the stress-free lattice parameter was observed. Crack formation is found to be a dominant mechanism for stress relaxation in the surface plane

  13. A theoretical model for prediction of deposition efficiency in cold spraying

    International Nuclear Information System (INIS)

    Li Changjiu; Li Wenya; Wang Yuyue; Yang Guanjun; Fukanuma, H.

    2005-01-01

    The deposition behavior of a spray particle stream with a particle size distribution was theoretically examined for cold spraying in terms of deposition efficiency as a function of particle parameters and spray angle. The theoretical relation was established between the deposition efficiency and spray angle. The experiments were conducted by measuring deposition efficiency at different driving gas conditions and different spray angles using gas-atomized copper powder. It was found that the theoretically estimated results agreed reasonably well with the experimental ones. Based on the theoretical model and experimental results, it was revealed that the distribution of particle velocity resulting from particle size distribution influences significantly the deposition efficiency in cold spraying. It was necessary for the majority of particles to achieve a velocity higher than the critical velocity in order to improve the deposition efficiency. The normal component of particle velocity contributed to the deposition of the particle under the off-nomal spray condition. The deposition efficiency of sprayed particles decreased owing to the decrease of the normal velocity component as spray was performed at off-normal angle

  14. Transcranial diffuse optical assessment of the microvascular reperfusion after thrombolysis for acute ischemic stroke.

    Science.gov (United States)

    Delgado-Mederos, Raquel; Gregori-Pla, Clara; Zirak, Peyman; Blanco, Igor; Dinia, Lavinia; Marín, Rebeca; Durduran, Turgut; Martí-Fàbregas, Joan

    2018-03-01

    In this pilot study, we have evaluated bedside diffuse optical monitoring combining diffuse correlation spectroscopy and near-infrared diffuse optical spectroscopy to assess the effect of thrombolysis with an intravenous recombinant tissue plasminogen activator (rtPA) on cerebral hemodynamics in an acute ischemic stroke. Frontal lobes of five patients with an acute middle cerebral artery occlusion were measured bilaterally during rtPA treatment. Both ipsilesional and contralesional hemispheres showed significant increases in cerebral blood flow, total hemoglobin concentration and oxy-hemoglobin concentration during the first 2.5 hours after rtPA bolus. The increases were faster and higher in the ipsilesional hemisphere. The results show that bedside optical monitoring can detect the effect of reperfusion therapy for ischemic stroke in real-time.

  15. Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction

    Science.gov (United States)

    Fritz, Bradley K.; Hoffmann, W. Clint

    2016-01-01

    When making an application of any crop protection material such as an herbicide or pesticide, the applicator uses a variety of skills and information to make an application so that the material reaches the target site (i.e., plant). Information critical in this process is the droplet size that a particular spray nozzle, spray pressure, and spray solution combination generates, as droplet size greatly influences product efficacy and how the spray moves through the environment. Researchers and product manufacturers commonly use laser diffraction equipment to measure the spray droplet size in laboratory wind tunnels. The work presented here describes methods used in making spray droplet size measurements with laser diffraction equipment for both ground and aerial application scenarios that can be used to ensure inter- and intra-laboratory precision while minimizing sampling bias associated with laser diffraction systems. Maintaining critical measurement distances and concurrent airflow throughout the testing process is key to this precision. Real time data quality analysis is also critical to preventing excess variation in the data or extraneous inclusion of erroneous data. Some limitations of this method include atypical spray nozzles, spray solutions or application conditions that result in spray streams that do not fully atomize within the measurement distances discussed. Successful adaption of this method can provide a highly efficient method for evaluation of the performance of agrochemical spray application nozzles under a variety of operational settings. Also discussed are potential experimental design considerations that can be included to enhance functionality of the data collected. PMID:27684589

  16. Triamcinolone Nasal Spray

    Science.gov (United States)

    ... class of medications called corticosteroids. It works by blocking the release of certain natural substances that cause ... 5 sprays into the air away from the face. If you have not used it for 2 ...

  17. Beclomethasone Nasal Spray

    Science.gov (United States)

    ... class of medications called corticosteroids. It works by blocking the release of certain natural substances that cause ... your thumb. Point the applicator away from your face. If you are using the spray for the ...

  18. Flunisolide Nasal Spray

    Science.gov (United States)

    ... class of medications called corticosteroids. It works by blocking the release of certain natural substances that cause ... your thumb. Point the applicator away from your face. If you are using the spray for the ...

  19. Spray solidification of nuclear waste

    International Nuclear Information System (INIS)

    Bonner, W.F.; Blair, H.T.; Romero, L.S.

    1976-08-01

    The spray calciner is a relatively simple machine. Operation is simple and is easily automated. Startup and shutdown can be performed in less than an hour. A wide variety of waste compositions and concentrations can be calcined under easily maintainable conditions. Spray calcination of high-level and mixed high- and intermediate-level liquid wastes has been demonstrated. Waste concentrations of from near infinite dilution to less than 225 liters per tonne of fuel are calcinable. Wastes have been calcined containing over 2M sodium. Feed concentration, composition, and flowrate can vary rapidly by over a factor of two without requiring operator action. Wastes containing mainly sodium cations can be spray calcined by addition of finely divided silica to the feedstock. A remotely replaceable atomizing nozzle has been developed for use in plant-scale equipment. Calciner capacity of over 75 l/h has been demonstrated in pilot-scale equipment. Sintered stainless steel filters are effective in deentraining over 99.9 percent of the solids that result from calcining the feedstock. The volume of recycle required from the effluent treatment system is very small. Vibrator action maintains the calcine holdup in the calciner at less than 1 kg. Successful remote operation and maintenance of a heated-wall spray calciner have been demonstrated while processing high-level waste. Radionuclide volatilization was acceptably low

  20. Spray drying formulation of amorphous solid dispersions.

    Science.gov (United States)

    Singh, Abhishek; Van den Mooter, Guy

    2016-05-01

    Spray drying is a well-established manufacturing technique which can be used to formulate amorphous solid dispersions (ASDs) which is an effective strategy to deliver poorly water soluble drugs (PWSDs). However, the inherently complex nature of the spray drying process coupled with specific characteristics of ASDs makes it an interesting area to explore. Numerous diverse factors interact in an inter-dependent manner to determine the final product properties. This review discusses the basic background of ASDs, various formulation and process variables influencing the critical quality attributes (CQAs) of the ASDs and aspects of downstream processing. Also various aspects of spray drying such as instrumentation, thermodynamics, drying kinetics, particle formation process and scale-up challenges are included. Recent advances in the spray-based drying techniques are mentioned along with some future avenues where major research thrust is needed. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Recombinant Tissue Plasminogen Activator Induces Neurological Side Effects Independent on Thrombolysis in Mechanical Animal Models of Focal Cerebral Infarction: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Mei-Xue Dong

    Full Text Available Recombinant tissue plasminogen activator (rtPA is the only effective drug approved by US FDA to treat ischemic stroke, and it contains pleiotropic effects besides thrombolysis. We performed a meta-analysis to clarify effect of tissue plasminogen activator (tPA on cerebral infarction besides its thrombolysis property in mechanical animal stroke.Relevant studies were identified by two reviewers after searching online databases, including Pubmed, Embase, and ScienceDirect, from 1979 to 2016. We identified 6, 65, 17, 12, 16, 12 and 13 comparisons reporting effect of endogenous tPA on infarction volume and effects of rtPA on infarction volume, blood-brain barrier, brain edema, intracerebral hemorrhage, neurological function and mortality rate in all 47 included studies. Standardized mean differences for continuous measures and risk ratio for dichotomous measures were calculated to assess the effects of endogenous tPA and rtPA on cerebral infarction in animals. The quality of included studies was assessed using the Stroke Therapy Academic Industry Roundtable score. Subgroup analysis, meta-regression and sensitivity analysis were performed to explore sources of heterogeneity. Funnel plot, Trim and Fill method and Egger's test were obtained to detect publication bias.We found that both endogenous tPA and rtPA had not enlarged infarction volume, or deteriorated neurological function. However, rtPA would disrupt blood-brain barrier, aggravate brain edema, induce intracerebral hemorrhage and increase mortality rate.This meta-analysis reveals rtPA can lead to neurological side effects besides thrombolysis in mechanical animal stroke, which may account for clinical exacerbation for stroke patients that do not achieve vascular recanalization with rtPA.

  2. Residual stress determination in thermally sprayed metallic deposits by neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Thomas; Margadant, Nikolaus; Pirling, Thilo; Riegert-Escribano, Maria J.; Wagner, Werner

    2004-05-25

    Neutron diffraction was used to obtain spatially resolved strain and stress profiles in thermally sprayed metallic 'NiCrAlY' deposits (chemical composition 67 wt.% Ni, 22 wt.% Cr, 10 wt.% Al, 1 wt.% Y) and the underlying steel substrates. Samples of four different spray techniques were analyzed: atmospheric and water stabilized plasma spraying (APS and WSP), flame spraying (FS) and wire arc spraying (WAS). The results are quantitatively compared with the average in-plane residual stress determined by complementary bending tests and the hole drilling technique. While the stress profiles from the surface to the interface in the deposits are similar for all investigated spray techniques, their absolute values and gradients vary strongly. This is attributed to different quenching stresses from the impinging particles, different thermal histories the deposit/substrate systems undergo during the spraying and subsequent cooling, and also to different coating properties. In the water stabilized plasma sprayed and the wire arc sprayed deposits, a gradient in the stress-free lattice parameter was observed. Crack formation is found to be a dominant mechanism for stress relaxation in the surface plane.

  3. Microalgal cell disruption via ultrasonic nozzle spraying.

    Science.gov (United States)

    Wang, M; Yuan, W

    2015-01-01

    The objective of this study was to understand the effect of operating parameters, including ultrasound amplitude, spraying pressure, nozzle orifice diameter, and initial cell concentration on microalgal cell disruption and lipid extraction in an ultrasonic nozzle spraying system (UNSS). Two algal species including Scenedesmus dimorphus and Nannochloropsis oculata were evaluated. Experimental results demonstrated that the UNSS was effective in the disruption of microalgal cells indicated by significant changes in cell concentration and Nile red-stained lipid fluorescence density between all treatments and the control. It was found that increasing ultrasound amplitude generally enhanced cell disruption and lipid recovery although excessive input energy was not necessary for best results. The effect of spraying pressure and nozzle orifice diameter on cell disruption and lipid recovery was believed to be dependent on the competition between ultrasound-induced cavitation and spraying-generated shear forces. Optimal cell disruption was not always achieved at the highest spraying pressure or biggest nozzle orifice diameter; instead, they appeared at moderate levels depending on the algal strain and specific settings. Increasing initial algal cell concentration significantly reduced cell disruption efficiency. In all UNSS treatments, the effectiveness of cell disruption and lipid recovery was found to be dependent on the algal species treated.

  4. Developments in the formulation and delivery of spray dried vaccines.

    Science.gov (United States)

    Kanojia, Gaurav; Have, Rimko Ten; Soema, Peter C; Frijlink, Henderik; Amorij, Jean-Pierre; Kersten, Gideon

    2017-10-03

    Spray drying is a promising method for the stabilization of vaccines, which are usually formulated as liquids. Usually, vaccine stability is improved by spray drying in the presence of a range of excipients. Unlike freeze drying, there is no freezing step involved, thus the damage related to this step is avoided. The edge of spray drying resides in its ability for particles to be engineered to desired requirements, which can be used in various vaccine delivery methods and routes. Although several spray dried vaccines have shown encouraging preclinical results, the number of vaccines that have been tested in clinical trials is limited, indicating a relatively new area of vaccine stabilization and delivery. This article reviews the current status of spray dried vaccine formulations and delivery methods. In particular it discusses the impact of process stresses on vaccine integrity, the application of excipients in spray drying of vaccines, process and formulation optimization strategies based on Design of Experiment approaches as well as opportunities for future application of spray dried vaccine powders for vaccine delivery.

  5. Developments in the formulation and delivery of spray dried vaccines

    Science.gov (United States)

    Kanojia, Gaurav; Have, Rimko ten; Soema, Peter C.; Frijlink, Henderik; Amorij, Jean-Pierre; Kersten, Gideon

    2017-01-01

    ABSTRACT Spray drying is a promising method for the stabilization of vaccines, which are usually formulated as liquids. Usually, vaccine stability is improved by spray drying in the presence of a range of excipients. Unlike freeze drying, there is no freezing step involved, thus the damage related to this step is avoided. The edge of spray drying resides in its ability for particles to be engineered to desired requirements, which can be used in various vaccine delivery methods and routes. Although several spray dried vaccines have shown encouraging preclinical results, the number of vaccines that have been tested in clinical trials is limited, indicating a relatively new area of vaccine stabilization and delivery. This article reviews the current status of spray dried vaccine formulations and delivery methods. In particular it discusses the impact of process stresses on vaccine integrity, the application of excipients in spray drying of vaccines, process and formulation optimization strategies based on Design of Experiment approaches as well as opportunities for future application of spray dried vaccine powders for vaccine delivery. PMID:28925794

  6. Applications of thermal spraying for automotive parts. Jidosha ni okeru yosha no tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Mori, K [Toyota Motor Co. Ltd., Aichi (Japan)

    1992-10-31

    Application of thermal spraying for automotive parts is described. Outlines of the spraying types that are materialized recently, like 'gel-double spraying of turbo-compressor housing part' and 'iron alloy spraying to outer portion of valve lifter made with Al alloy', are introduced. Gel-double spraying technology is widely used in the jet engine of aeroplane, however its use in automotive turbo was difficult from the reason like quality assurance relating to continuous production of automotives. As a result of the research and development based on the above reasons, a low speed torque is confirmed by the formation of gel-double spray layer. Spraying to the outer part of the valve lifter made from Al alloy is cited as the best example of thermal spraying. Relation between flying speed of spraying particles and degree of flattening, etc., relating to the conformity of adhesion power of coated layer, is explained. Further research topics are given as; improvement of spraying efficiency, improvement of resistance of spraying equipments, unification of equipments standards, quantification of spray coatings, design of spray materials, etc. 9 refs., 8 figs., 1 tab.

  7. Micrometeorological measurements during the Blackmo 88 spray trials

    Science.gov (United States)

    D. E. Anderson; D. R. Miller; Y. S. Wang; W. E. Yendol; M. L. McManus

    1991-01-01

    Instrumentation was arrayed on a 120 foot tower to detail the local atmospheric conditions during the Blackmo 88 spray experiment. Measurements were continuous for 30 minute periods encompassing each spray pass.

  8. Suspension plasma sprayed composite coating using amorphous powder feedstock

    International Nuclear Information System (INIS)

    Chen Dianying; Jordan, Eric H.; Gell, Maurice

    2009-01-01

    Al 2 O 3 -ZrO 2 composite coatings were deposited by the suspension plasma spray process using molecularly mixed amorphous powders. X-ray diffraction (XRD) analysis shows that the as-sprayed coating is composed of α-Al 2 O 3 and tetragonal ZrO 2 phases with grain sizes of 26 nm and 18 nm, respectively. The as-sprayed coating has 93% density with a hardness of 9.9 GPa. Heat treatment of the as-sprayed coating reveals that the Al 2 O 3 and ZrO 2 phases are homogeneously distributed in the composite coating

  9. Droplets Behavior of Hollow-Cone Spray in a Non-Condensable Environment

    International Nuclear Information System (INIS)

    Minoru Takahashi; Shin-ichi Kitagawa; Suizheng Qiu

    2002-01-01

    The characteristics of droplets in a water hollow-cone spray from nozzles 1.1 mm and 3.6 mm in diameter in an air environment have been investigated experimentally. The dual phase Doppler anemometry (PDA) system was used to measure the size and two velocity components of individual spherical particles. The liquid spray geometry, including spray breakup length and spray angle were also obtained experimentally. The mechanism and the influence of these parameters on a hollow cone spray flow were described. (authors)

  10. Modeling the influence of nozzle-generated turbulence on diesel sprays

    Energy Technology Data Exchange (ETDEWEB)

    Magnotti, G M; Matusik, K E; Duke, D J; Knox, B W; Martinez, G L; Powell, C F; Kastengren, A L; Genzale, C L

    2017-05-18

    The physical mechanisms governing spray breakup in direct injection engines, such as aerodynamic induced instabilities and nozzle-generated cavitation and turbulence, are not well understood due to the experimental and computational limitations in resolving these processes. Recent x-ray and visible extinction measurements have been con-ducted with a targeted interest in the spray formation region in order to characterize the distribution of droplet sizes throughout the spray. Detailed analysis of these measurements shows promise of yielding insight into likely mechanisms governing atomization, which can inform the improvement of spray models for engine computational fluid dynamic (CFD) codes. In order to investigate potential atomization mechanisms, we employ a joint experimental and computational approach to characterize the structure of the spray formation region using the Engine Combustion Network Spray D injector. X-ray tomography, radiography and ultra-small angle x-ray scattering measurements conducted at the Advanced Photon Source at Argonne National Laboratory quantify the injector geometry, liquid fuel mass and Sauter mean diameter (SMD) distributions under non-vaporizing conditions. Diffused back-illumination imaging measurements, conducted at the Georgia Institute of Technology, characterize the asymmetry of the spray structure. The selected range of injection pressures (50 – 150 MPa) and ambient densities (1.2 – 22.8 kg/m3) allow for the influence of aerodynamic forces on the spray to be studied in a controlled and systematic manner, while isolating the atomization process from the effects of vaporization. In comparison to high ambient density conditions, the spray is observed to be more asymmetric at low ambient density conditions. Although several mechanisms may cause asymmetries in the nozzle exit flow conditions and ultimately the spray distribution, irregularities in the internal nozzle geometry were identified, suggesting an increased

  11. Experimental Analysis of Tensile Mechanical Properties of Sprayed FRP

    Directory of Open Access Journals (Sweden)

    Zhao Yang

    2016-01-01

    Full Text Available To study the tensile mechanical properties of sprayed FRP, 13 groups of specimens were tested through uniaxial tensile experiments, being analyzed about stress-strain curve, tensile strength, elastic modulus, breaking elongation, and other mechanical properties. Influencing factors on tensile mechanical properties of sprayed FRP such as fiber type, resin type, fiber volume ratio, fiber length, and composite thickness were studied in the paper too. The results show that both fiber type and resin type have an obvious influence on tensile mechanical properties of sprayed FRP. There will be a specific fiber volume ratio for sprayed FRP to obtain the best tensile mechanical property. The increase of fiber length can lead to better tensile performance, while that of composite thickness results in property degradation. The study can provide reference to popularization and application of sprayed FRP material used in structure reinforcement.

  12. Automatic targeting of plasma spray gun

    Science.gov (United States)

    Abbatiello, Leonard A.; Neal, Richard E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is provided. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun.

  13. Automatic targeting of plasma spray gun

    International Nuclear Information System (INIS)

    Abbatiello, L.A.; Neal, R.E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is described. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun

  14. Experimental investigation of spray characteristics of alternative aviation fuels

    International Nuclear Information System (INIS)

    Kannaiyan, Kumaran; Sadr, Reza

    2014-01-01

    Highlights: • Physical properties of GTL fuel are different from those of conventional jet fuels. • Spray characteristics of GTL and Jet A-1 fuels are experimentally investigated using phase Doppler anemometry. • Regions near the nozzle are influenced by differences in fuel physical properties. • Spray characteristics of GTL can be predicted by empirical relations developed for conventional jet fuels. - Abstract: Synthetic fuels derived from non-oil feedstock are gaining importance due to their cleaner combustion characteristics. This work investigates spray characteristics of two Gas-to-Liquid (GTL) synthetic jet fuels from a pilot-scale pressure swirl nozzle and compares them with those of the conventional Jet A-1 fuel. The microscopic spray parameters are measured at 0.3 and 0.9 MPa injection pressures at several points in the spray using phase Doppler anemometry. The results show that the effect of fuel physical properties on the spray characteristics is predominantly evident in the regions close to the nozzle exit at the higher injection pressure. The lower viscosity and surface tension of GTL fuel seems to lead to faster disintegration and dispersion of the droplets when compared to those of Jet A-1 fuel under atmospheric conditions. Although the global characteristics of the fuels are similar, the effects of fuel properties are evident on the local spray characteristics at the higher injection pressure

  15. Experiments on aerosol removal by high-pressure water spray

    Energy Technology Data Exchange (ETDEWEB)

    Corno, Ada del, E-mail: delcorno@rse-web.it [RSE, Power Generation Technologies and Materials Dept, via Rubattino 54, I-20134 Milano (Italy); Morandi, Sonia, E-mail: morandi@rse-web.it [RSE, Power Generation Technologies and Materials Dept, via Rubattino 54, I-20134 Milano (Italy); Parozzi, Flavio, E-mail: parozzi@rse-web.it [RSE, Power Generation Technologies and Materials Dept, via Rubattino 54, I-20134 Milano (Italy); Araneo, Lucio, E-mail: lucio.araneo@polimi.it [Politecnico di Milano, Department of Energy, via Lambruschini 4A, I-20156 Milano (Italy); CNR-IENI, via Cozzi 53, I-20125 Milano (Italy); Casella, Francesco, E-mail: francesco2.casella@mail.polimi.it [Politecnico di Milano, Department of Energy, via Lambruschini 4A, I-20156 Milano (Italy)

    2017-01-15

    Highlights: • Experimental research to measure the efficiency of high-pressure sprays in capturing aerosols if applied to a filtered containment venting system in case of severe accident. • Cloud of monodispersed SiO{sub 2} particles with sizes 0.5 or 1.0 μm and initial concentration in the range 2–90 mg/m{sup 3}. • Carried out in a chamber 0.5 × 1.0 m and 1.5 m high, with transparent walls equipped with a high pressure water spray with single nozzle. • Respect to low-pressure sprays, removal efficiency turned out significant: the half-life for 1 μm particles with a removal high-pressure spray system is orders of magnitude shorter than that with a low-pressure sprays system. - Abstract: An experimental research was managed in the framework of the PASSAM European Project to measure the efficiency of high-pressure sprays in capturing aerosols when applied to a filtered containment venting system in case of severe accident. The campaign was carried out in a purposely built facility composed by a scrubbing chamber 0.5 × 1.0 m and 1.5 m high, with transparent walls to permit the complete view of the aerosol removal process, where the aerosol was injected to form a cloud of specific particle concentration. The chamber was equipped with a high pressure water spray system with a single nozzle placed on its top. The test matrix consisted in the combination of water pressure injections, in the range 50–130 bar, on a cloud of monodispersed SiO{sub 2} particles with sizes 0.5 or 1.0 μm and initial concentration ranging between 2 and 99 mg/m{sup 3}. The spray was kept running for 2 min and the efficiency of the removal was evaluated, along the test time, using an optical particle sizer. With respect to low-pressure sprays, the removal efficiency turned out much more significant: the half-life for 1 μm particles with a removal high-pressure spray system is orders of magnitude shorter than that with a low-pressure spray system. The highest removal rate was

  16. Experiments on aerosol removal by high-pressure water spray

    International Nuclear Information System (INIS)

    Corno, Ada del; Morandi, Sonia; Parozzi, Flavio; Araneo, Lucio; Casella, Francesco

    2017-01-01

    Highlights: • Experimental research to measure the efficiency of high-pressure sprays in capturing aerosols if applied to a filtered containment venting system in case of severe accident. • Cloud of monodispersed SiO_2 particles with sizes 0.5 or 1.0 μm and initial concentration in the range 2–90 mg/m"3. • Carried out in a chamber 0.5 × 1.0 m and 1.5 m high, with transparent walls equipped with a high pressure water spray with single nozzle. • Respect to low-pressure sprays, removal efficiency turned out significant: the half-life for 1 μm particles with a removal high-pressure spray system is orders of magnitude shorter than that with a low-pressure sprays system. - Abstract: An experimental research was managed in the framework of the PASSAM European Project to measure the efficiency of high-pressure sprays in capturing aerosols when applied to a filtered containment venting system in case of severe accident. The campaign was carried out in a purposely built facility composed by a scrubbing chamber 0.5 × 1.0 m and 1.5 m high, with transparent walls to permit the complete view of the aerosol removal process, where the aerosol was injected to form a cloud of specific particle concentration. The chamber was equipped with a high pressure water spray system with a single nozzle placed on its top. The test matrix consisted in the combination of water pressure injections, in the range 50–130 bar, on a cloud of monodispersed SiO_2 particles with sizes 0.5 or 1.0 μm and initial concentration ranging between 2 and 99 mg/m"3. The spray was kept running for 2 min and the efficiency of the removal was evaluated, along the test time, using an optical particle sizer. With respect to low-pressure sprays, the removal efficiency turned out much more significant: the half-life for 1 μm particles with a removal high-pressure spray system is orders of magnitude shorter than that with a low-pressure spray system. The highest removal rate was detected with 1

  17. Sea Spray Aerosols

    DEFF Research Database (Denmark)

    Butcher, Andrew Charles

    emissions produced directly from bubble bursting as the result of air entrainment from breaking waves and particles generated from secondary emissions of volatile organic compounds. In the first paper, we study the chemical properties of particles produced from several sea water proxies with the use...... of a cloud condensation nuclei ounter. Proxy solutions with high inorganic salt concentrations and some organics produce sea spray aerosol particles with little change in cloud condensation activity relative to pure salts. Comparison is made between a frit based method for bubble production and a plunging...... a relationship between plunging jet particle ux, oceanic particle ux, and energy dissipation rate in both systems. Previous sea spray aerosol studies dissipate an order of magnitude more energy for the same particle ux production as the open ocean. A scaling factor related to the energy expended in air...

  18. Randomized assessment of imatinib in patients with acute ischaemic stroke treated with intravenous thrombolysis.

    Science.gov (United States)

    Wahlgren, N; Thorén, M; Höjeberg, B; Käll, T-B; Laska, A-C; Sjöstrand, C; Höijer, J; Almqvist, H; Holmin, S; Lilja, A; Fredriksson, L; Lawrence, D; Eriksson, U; Ahmed, N

    2017-03-01

    Imatinib, a tyrosine kinase inhibitor, has been shown to restore blood-brain barrier integrity and reduce infarct size, haemorrhagic transformation and cerebral oedema in stroke models treated with tissue plasminogen activator. We evaluated the safety of imatinib, based on clinical and neuroradiological data, and its potential influence on neurological and functional outcomes. A phase II randomized trial was performed in patients with acute ischaemic stroke treated with intravenous thrombolysis. A total of 60 patients were randomly assigned to four groups [3 (active): 1 (control)]; the active treatment groups received oral imatinib for 6 days at three dose levels (400, 600 and 800 mg). Primary outcome was any adverse event; secondary outcomes were haemorrhagic transformation, cerebral oedema, neurological severity on the National Institutes of Health Stroke Scale (NIHSS) at 7 days and at 3 months and functional outcomes on the modified Rankin scale (mRS). Four serious adverse events were reported, which resulted in three deaths (one in the control group and two in the 400-mg dose group; one patient in the latter group did not receive active treatment and the other received two doses). Nonserious adverse events were mostly mild, resulting in full recovery. Imatinib ameliorated neurological outcomes with an improvement of 0.6 NIHSS points per 100 mg imatinib (P = 0.02). For the 800-mg group, the mean unadjusted and adjusted NIHSS improvements were 4 (P = 0.037) and 5 points (P = 0.012), respectively, versus controls. Functional independence (mRS 0-2) increased by 18% versus controls (61 vs. 79; P = 0.296). This phase II study showed that imatinib is safe and tolerable and may reduce neurological disability in patients treated with intravenous thrombolysis after ischaemic stroke. A confirmatory randomized trial is currently underway. © 2016 The Authors. Journal of Internal Medicine published by John Wiley & Sons Ltd on behalf of Association for Publication of The

  19. Effects of self-pulsation on the spray characteristics of gas-liquid swirl coaxial injector

    Science.gov (United States)

    Kang, Zhongtao; Li, Qinglian; Cheng, Peng; Zhang, Xinqiao; Wang, Zhen-guo

    2016-10-01

    To understand the influence of self-pulsation on the spray characteristics of gas-liquid swirl coaxial injector, a back-lighting photography technique has been employed to capture the instantaneous self-pulsated spray and stable spray images with a high speed camera. The diameter and velocity of the droplets in the spray have been characterized with a Dantec Phase Doppler Anemometry (PDA) system. The effects of self-pulsation on the spray pattern, primary breakup, spray angle, diameter and velocity distribution and mass flow rate distribution are analyzed and discussed. The results show that the spray morphology is greatly influenced by self-pulsation. The stable spray has a cone shape, while the self-pulsated spray looks like a Christmas tree. The main difference of these two sprays is the primary breakup. The liquid film of stable spray keeps stable while that of self-pulsated spray oscillates periodically. The film width of self-pulsated spray varies in a large range with 'neck' and 'shoulder' features existing. The liquid film of self-pulsated spray breaks up at the second neck, and then the second shoulder begins to breakup into ligaments. The self-pulsated spray produces droplet clusters periodically, varies horizontal spray width and mass flux periodically. From the point of spatial distribution, self-pulsation is good for the spray, it uniformizes the mass flux along radius and increases the spray angle. However, when self-pulsation occurs, the SMD distribution varies from an inverted V shape to a hollow cone shape, and SMD increases at all the measuring points. Namely, from the point of atomization performance, self-pulsation has negative effects even when the breakup length is smaller. The effects of self-pulsation on the diameter and velocity distributions of the spray are mainly in the center part of the spray. The periphery of stable and self-pulsated spray has similar diameter and velocity distribution.

  20. Experiments on the spray nozzles used in the pressurizer of power reactor

    International Nuclear Information System (INIS)

    Diao Wentang

    1989-04-01

    The spray nozzle, which is used in the pressurizer of pressurized water reactor system, usually uses a less differential pressure between the reactor inlet and outlet as the spray drive pressure, but its flow rate is relatively larger. It is difficult to obtain a optimum spray performance of such a nozzle. The experimental results of five types of twenty seven spray nozzles in different structures and sizes with the range of the spray drive pressure from 0.127 to 0.245 MPa and the flow rates from 5 to 50 t/h are given. The main factors affecting spray performances and their distribution characteristics have been found. And some relatively suitable spray structures have been recommended, which can be used as references for improving the spray nozzles used in the pressurizers of existing PWRs or of the PWRs to be built

  1. Experimental characterisation of sprays resulting from impacts of liquid-containing projectiles

    Energy Technology Data Exchange (ETDEWEB)

    Hostikka, Simo, E-mail: simo.hostikka@aalto.fi [Aalto University, Espoo (Finland); Silde, Ari; Sikanen, Topi; Vepsä, Ari; Paajanen, Antti [VTT Technical Research Centre of Finland Ltd, Espoo (Finland); Honkanen, Markus [Pixact Oy, Tampere (Finland)

    2015-12-15

    Highlights: • Detailed characterisation of sprays resulting from the impacts of water-filled metal projectiles on a hard wall. • Experimental measurements of spray speed, direction and droplet size. • Detailed analysis of overall spray evolution. • The spray characterisation information can be used in CFD analyses of aircraft impact fires. - Abstract: Modelling and analysing fires following aircraft impacts requires information about the behaviour of liquid fuel. In this study, we investigated sprays resulting from the impacts of water-filled metal projectiles on a hard wall. The weights of the projectiles were in the range of 38–110 kg, with 8.6–68 kg water, and the impact speeds varied between 96 and 169 m/s. The overall spray behaviour was observed with high-speed video cameras. Ultra-high-speed cameras were used in backlight configuration for measuring the droplet size and velocity distributions. The results indicate that the liquid leaves the impact position as a thin sheet of spray in a direction perpendicular to the projectile velocity. The initial spray speeds were 1.5–2.5 times the impact speed, and the Sauter mean diameters were in the 147–344 μm range. This data can be used as boundary conditions in CFD fire analyses, considering the two-phase fuel flow. The overall spray observations, including the spray deceleration rate, can be used for validating the model.

  2. Agricultural sprays in cross-flow and drift

    DEFF Research Database (Denmark)

    Farooq, M.; Balachandar, R.; Wulfsohn, Dvoralai

    2001-01-01

    The droplet size and velocity characteristics of an agricultural spray were studied in a wind tunnel in the presence of a non-uniform cross-flow. The spray was generated at three nozzle-operating pressures. The droplet size and velocity was measured in both the cross-flow direction and the vertical...

  3. Preliminary Design of Aerial Spraying System for Microlight Aircraft

    Science.gov (United States)

    Omar, Zamri; Idris, Nurfazliawati; Rahim, M. Zulafif

    2017-10-01

    Undoubtedly agricultural is an important sector because it provides essential nutrients for human, and consequently is among the biggest sector for economic growth worldwide. It is crucial to ensure crops production is protected from any plant diseases and pests. Thus aerial spraying system on crops is developed to facilitate farmers to for crops pests control and it is very effective spraying method especially for large and hilly crop areas. However, the use of large aircraft for aerial spaying has a relatively high operational cost. Therefore, microlight aircraft is proposed to be used for crops aerial spraying works for several good reasons. In this paper, a preliminary design of aerial spraying system for microlight aircraft is proposed. Engineering design methodology is adopted in the development of the aerial sprayer and steps involved design are discussed thoroughly. A preliminary design for the microlight to be attached with an aerial spraying system is proposed.

  4. A user-friendly model for spray drying to aid pharmaceutical product development.

    Science.gov (United States)

    Grasmeijer, Niels; de Waard, Hans; Hinrichs, Wouter L J; Frijlink, Henderik W

    2013-01-01

    The aim of this study was to develop a user-friendly model for spray drying that can aid in the development of a pharmaceutical product, by shifting from a trial-and-error towards a quality-by-design approach. To achieve this, a spray dryer model was developed in commercial and open source spreadsheet software. The output of the model was first fitted to the experimental output of a Büchi B-290 spray dryer and subsequently validated. The predicted outlet temperatures of the spray dryer model matched the experimental values very well over the entire range of spray dryer settings that were tested. Finally, the model was applied to produce glassy sugars by spray drying, an often used excipient in formulations of biopharmaceuticals. For the production of glassy sugars, the model was extended to predict the relative humidity at the outlet, which is not measured in the spray dryer by default. This extended model was then successfully used to predict whether specific settings were suitable for producing glassy trehalose and inulin by spray drying. In conclusion, a spray dryer model was developed that is able to predict the output parameters of the spray drying process. The model can aid the development of spray dried pharmaceutical products by shifting from a trial-and-error towards a quality-by-design approach.

  5. Kinematic Optimization of Robot Trajectories for Thermal Spray Coating Application

    Science.gov (United States)

    Deng, Sihao; Liang, Hong; Cai, Zhenhua; Liao, Hanlin; Montavon, Ghislain

    2014-12-01

    Industrial robots are widely used in the field of thermal spray nowadays. Due to their characteristics of high-accuracy and programmable flexibility, spraying on complex geometrical workpieces can be realized in the equipped spray room. However, in some cases, the robots cannot guarantee the process parameters defined by the robot movement, such as the scanning trajectory, spray angle, relative speed between the torch and the substrate, etc., which have distinct influences on heat and mass transfer during the generation of any thermally sprayed coatings. In this study, an investigation on the robot kinematics was proposed to find the rules of motion in a common case. The results showed that the motion behavior of each axis of robot permits to identify the motion problems in the trajectory. This approach allows to optimize the robot trajectory generation in a limited working envelop. It also minimizes the influence of robot performance to achieve a more constant relative scanning speed which is represented as a key parameter in thermal spraying.

  6. Spray structure of a pressure-swirl atomizer for combustion applications

    Directory of Open Access Journals (Sweden)

    Jicha Miroslav

    2012-04-01

    Full Text Available In the present work, global as well as spatially resolved parameters of a spray produced by a pressure-swirl atomizer are obtained. Small pressure-swirl atomizer for aircraft combustion chambers was run on a newly designed test bench with Jet A-1 kerosene type aviation fuel. The atomizer was tested in four regimes based on typical operation conditions of the engine. Spray characteristics were studied using two optical measurement systems, Particle Image velocimetry (PIV and Phase-Doppler Particle Analyzer (P/DPA. The results obtained with P/DPA include information about Sauter Mean Diameter of droplets and spray velocity profiles in one plane perpendicular to the spray axis. Velocity magnitudes of droplets in an axial section of the spray were obtained using PIV. The experimental outputs also show a good confirmation of velocity profiles obtained with both instruments in the test plane. These data together will elucidate impact of the spray quality on the whole combustion process, its efficiency and exhaust gas emissions.

  7. Spray structure of a pressure-swirl atomizer for combustion applications

    Science.gov (United States)

    Durdina, Lukas; Jedelsky, Jan; Jicha, Miroslav

    2012-04-01

    In the present work, global as well as spatially resolved parameters of a spray produced by a pressure-swirl atomizer are obtained. Small pressure-swirl atomizer for aircraft combustion chambers was run on a newly designed test bench with Jet A-1 kerosene type aviation fuel. The atomizer was tested in four regimes based on typical operation conditions of the engine. Spray characteristics were studied using two optical measurement systems, Particle Image velocimetry (PIV) and Phase-Doppler Particle Analyzer (P/DPA). The results obtained with P/DPA include information about Sauter Mean Diameter of droplets and spray velocity profiles in one plane perpendicular to the spray axis. Velocity magnitudes of droplets in an axial section of the spray were obtained using PIV. The experimental outputs also show a good confirmation of velocity profiles obtained with both instruments in the test plane. These data together will elucidate impact of the spray quality on the whole combustion process, its efficiency and exhaust gas emissions.

  8. Visible Photodetectors Based on Organic-Inorganic Hybrids Using Electrostatic Spraying Technology

    Directory of Open Access Journals (Sweden)

    Liang-Wen Ji

    2013-12-01

    Full Text Available This paper discusses an organic-inorganic hybrid white photodetector with the structure of ITO /AZO/ZnO NWs:P3HT: PCBM/PEDOT: PSS/Al produced with an electrostatic spraying method. The method of production was as follows: First, different spraying methods (continuous spraying, discontinuous spraying and different spraying times were tested before the final electrostatic spraying. Then, different annealing times (10 min and 20 min were tested to anneal the coated film. Lastly, we investigated the photoelectric properties, including transparency analysis of the film surface topography through XRD, OM, FE-SEM, AFM and UV-VIS. The results showed that the detector with discontinuous spraying and 20 mins annealing had a photocurrent of approx. 22.1×10-4A, dark current (drain current of approx. 1.94×10-7A, and a ratio of photocurrent to dark current of approximately 1.14×104, which produced optimal photoelectric characteristics.

  9. Sequential cryogen spraying for heat flux control at the skin surface

    Science.gov (United States)

    Majaron, Boris; Aguilar, Guillermo; Basinger, Brooke; Randeberg, Lise L.; Svaasand, Lars O.; Lavernia, Enrique J.; Nelson, J. Stuart

    2001-05-01

    Heat transfer rate at the skin-air interface is of critical importance for the benefits of cryogen spray cooling in combination with laser therapy of shallow subsurface skin lesions, such as port-wine stain birthmarks. With some cryogen spray devices, a layer of liquid cryogen builds up on the skin surface during the spurt, which may impair heat transfer across the skin surface due to relatively low thermal conductivity and potentially higher temperature of the liquid cryogen layer as compared to the spray droplets. While the mass flux of cryogen delivery can be adjusted by varying the atomizing nozzle geometry, this may strongly affect other spray properties, such as lateral spread (cone), droplet size, velocity, and temperature distribution. We present here first experiments with sequential cryogen spraying, which may enable accurate mass flux control through variation of spray duty cycle, while minimally affecting other spray characteristics. The observed increase of cooling rate and efficiency at moderate duty cycle levels supports the above described hypothesis of isolating liquid layer, and demonstrates a novel approach to optimization of cryogen spray devices for individual laser dermatological applications.

  10. The influence of spray properties on intranasal deposition.

    Science.gov (United States)

    Foo, Mow Yee; Cheng, Yung-Sung; Su, Wei-Chung; Donovan, Maureen D

    2007-01-01

    While numerous devices, formulations, and spray characteristics have been shown to influence nasal deposition efficiency, few studies have attempted to identify which of these interacting factors plays the greatest role in nasal spray deposition. The deposition patterns of solutions with a wide range of surface tensions and viscosities were measured using an MRI-derived nasal cavity replica. The resulting spray plumes had angles between 29 degrees and 80 degrees and contained droplet sizes (D(v50)) from 37-157 microm. Each formulation contained rhodamine 590 as a fluorescent marker for detection. Administration angles of 30 degrees , 40 degrees , or 50 degrees above horizontal were tested to investigate the role of user technique on nasal deposition. The amount of spray deposited within specific regions of the nasal cavity was determined by disassembling the replica and measuring the amount of rhodamine retained in each section. Most of the spray droplets were deposited onto the anterior region of the model, but sprays with small plume angles were capable of reaching the turbinate region with deposition efficiencies approaching 90%. Minimal dependence on droplet size, viscosity, or device was observed. Changes in inspiratory flow rate (0-60 L/min) had no significant effect on turbinate deposition efficiency. Both plume angle and administration angle were found to be important factors in determining deposition efficiency. For administration angles of 40 degrees or 50 degrees , maximal turbinate deposition efficiency (30-50%) occurred with plume angles of 55-65 degrees , whereas a 30 degrees administration angle gave an approximately 75% deposition efficiency for similar plume angles. Deposition efficiencies of approximately 90% could be achieved with plume angles deposition efficiency, while many other spray parameters, including particle size, have relatively minor influences on deposition within the nasal cavity.

  11. Lanthanide-based laser-induced phosphorescence for spray diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Voort, D. D. van der, E-mail: d.d.v.d.voort@tue.nl; Water, W. van de; Kunnen, R. P. J.; Clercx, H. J. H.; Heijst, G. J. F. van [Applied Physics Department, Eindhoven University of Technology, 5612 AZ Eindhoven (Netherlands); Maes, N. C. J.; Sweep, A. M.; Dam, N. J. [Mechanical Engineering Department, Eindhoven University of Technology, 5612 AZ Eindhoven (Netherlands); Lamberts, T. [Institute of Theoretical Chemistry, University of Stuttgart, D-70569 Stuttgart (Germany)

    2016-03-15

    Laser-induced phosphorescence (LIP) is a relatively recent and versatile development for studying flow dynamics. This work investigates certain lanthanide-based molecular complexes for their use in LIP for high-speed sprays. Lanthanide complexes in solutions have been shown to possess long phosphorescence lifetimes (∼1-2 ms) and to emit light in the visible wavelength range. In particular, europium and terbium complexes are investigated using fluorescence/phosphorescence spectrometry, showing that europium-thenoyltrifluoracetone-trioctylphosphineoxide (Eu-TTA-TOPO) can be easily and efficiently excited using a standard frequency-tripled Nd:YAG laser. The emitted spectrum, with maximum intensity at a wavelength of 614 nm, is shown not to vary strongly with temperature (293-383 K). The decay constant of the phosphorescence, while independent of ambient pressure, decreases by approximately 12 μs/K between 323 and 373 K, with the base level of the decay constant dependent on the used solvent. The complex does not luminesce in the gas or solid state, meaning only the liquid phase is visualized, even in an evaporating spray. By using an internally excited spray containing the phosphorescent complex, the effect of vaporization is shown through the decrease in measured intensity over the length of the spray, together with droplet size measurements using interferometric particle imaging. This study shows that LIP, using the Eu-TTA-TOPO complex, can be used with different solvents, including diesel surrogates. Furthermore, it can be easily handled and used in sprays to investigate spray breakup and evaporation.

  12. NACOM - a code for sodium spray fire analysis

    International Nuclear Information System (INIS)

    Rao, P.M.; Kannan, S.E.

    2002-01-01

    Full text: In liquid metal fast breeder reactors (LMFBR), leakage of sodium can result in a spray fire. Because of higher burning rates in droplet form combustion of sodium in spray fire, thermal consequences are more severe than that in a sodium pool fire. The code NACOM was developed for the analysis of sodium spray fires in LMFBRs facilities. The code uses the validated model for estimating the falling droplet burning rates in pre-ignition and vapour phase combustion stages. It uses a distribution system to generate the droplet groups of different diameters that represent the spray. The code requires about 20 input parameters like sodium leak rates, sodium temperature, initial cell conditions like oxygen concentration, temperature and dimensions. NACOM is a validated code based on experiments with sodium inventory up to 650 kg in 0 to 21 % O 2 atmospheres. The paper brings out the salient features of the code along with the sensitivity analysis of the main input parameters like spray volume mean diameter, oxygen concentration etc. based on the results obtained. The limitations of the code and the confidence margins applicable to results obtained are also brought out

  13. Numerical studies of spray breakup in a gasoline direct injection (GDI engine

    Directory of Open Access Journals (Sweden)

    Jafarmadar Samad

    2011-01-01

    Full Text Available The objective of this study is to investigate Spray Breakup process of sprays injected from single and two-hole nozzles for gasoline direct Injection (GDI engines by using three dimensional CFD code. Spray characteristics were examined for spray tip penetration and other characteristics including: the vapor phase concentration distribution and droplet spatial distribution, which were acquired using the computational fluid dynamics (CFD simulation. Results showed that as the hole-axis-angle (γ of the two-hole nozzle decreased, the droplet coalescence increased and vapor mass decreased. The spray with cone angle (θ0 5 deg for single hole nozzle has the longest spray tip penetration and the spray with the γ of 30 deg and spray cone angle θ0=30 deg for two hole nozzles had the shortest one. Also, when the spray cone angle (θ0 and hole-axis-angle (γ increased from 5 to 30 deg, the Sauter mean diameter (SMD decreased for both single-hole and two-hole nozzles used in this study. For a single-hole nozzle, when spray cone angle increased from 5 to 30 deg, the vaporization rate very much because of low level of coalescence. The result of model for tip penetration is good agreement with the corresponding experimental data in the literatures.

  14. Photoelectrode Fabrication of Dye-Sensitized Nanosolar Cells Using Multiple Spray Coating Technique

    Directory of Open Access Journals (Sweden)

    Chien-Chih Chen

    2013-01-01

    Full Text Available This paper presents a spray coating technique for fabricating nanoporous film of photoelectrode in dye-sensitized nanosolar cells (DSSCs. Spray coating can quickly fabricate nanoporous film of the photoelectrode with lower cost, which can further help the DSSCs to be commercialized in the future. This paper analyzed photoelectric conversion efficiency of the DSSCs using spray coated photoelectrode in comparison with the photoelectrode made with the doctor blade method. Spray coating can easily control transmittance of the photoelectrode through the multiple spray coating process. This work mainly used a dispersant with help of ultrasonic oscillation to prepare the required nano-TiO2 solution and then sprayed it on the ITO glasses. In this work, a motor-operated conveyor belt was built to transport the ITO glasses automatically for multiple spray coating and drying alternately. Experiments used transmittance of the photoelectrode as a fabrication parameter to analyze photoelectric conversion efficiency of the DSSCs. The influencing factors of the photoelectrode transmittance during fabrication are the spray flow rate, the spray distance, and the moving speed of the conveyor belt. The results show that DSSC with the photoelectrode transmittance of ca. 68.0 ± 1.5% and coated by the spray coating technique has the best photoelectric conversion efficiency in this work.

  15. Biofouling of Cr-Nickel Spray Coated Films on Steel Surfaces

    International Nuclear Information System (INIS)

    Yoshida, Kento; Kanematsu, Hideyuki; Kuroda, Daisuke; Ikigai, Hajime; Kogo, Takeshi; Yokoyama, Seiji

    2012-01-01

    Nowadays, corrosion of metals brings us serious economic loss and it often reaches several percentage of GNP. Particularly the marine corrosion was serious and the counter measure was very hard to be established, since the number of factors is huge and complicated. One of the complicated factors in marine corrosion is biofouling. Biofouling was classified into two main categories, microfouling and macrofouling. The former is composed of biofilm formation mainly. Marine bacteria are attached to material surfaces, seeking for nutrition in oligotrophic environment and they excrete polysaccharide to form biofilm on metal surfaces. Then larger living matters are attached on the biofilms to develop biofouling on metal surfaces, which often lead loss and failures of metals in marine environments. From the viewpoint of corrosion protection and maintenance of marine structures, biofouling should be mitigated as much as possible. In this study, we applied spray coating to steels and investigated if chromium-nickel spray coating could mitigate the biofouling, being compared with the conventional aluminium-zinc spray coating in marine environments. The specimens used for this investigation are aluminium, zinc, aluminium-zinc, stacked chromium/nickel and those films were formed on carbon steel (JIS SS400). And the pores formed by spray coating were sealed by a commercial reagent for some specimens. All of those specimens were immersed into sea water located at Marina Kawage (854-3, Chisato, Tsu, Mie Prefecture) in Ise Bay for two weeks. The depth of the specimen was two meter from sea water surface and the distance was always kept constant, since they were suspended from the floating pier. The temperature in sea water changed from 10 to 15 degrees Celsius during the immersion test. The biofouling behavior was investigated by low vacuum SEM (Hitachi Miniscope TM1000) and X-ray fluorescent analysis. When the spray coated specimens with and without sealing agents were compared

  16. [Investigation on Spray Drying Technology of Auricularia auricular Extract].

    Science.gov (United States)

    Zhou, Rong; Chen, Hui; Xie, Yuan; Chen, Peng; Wang, Luo-lin

    2015-07-01

    To investigate the feasibility of spray drying technology of Auricularia auricular extract and its optimum process. On the basis of single factor test, with the yield of dry extract and the content of polysaccharide as indexes, orthogonal test method was used to optimize the spray drying technology on the inlet air temperature, injection speed and crude drug content. Using ultraviolet spectrophotometry, thin layer chromatography(TLC) and pharmacodynamics as indicators, extracts prepared by traditional alcohol precipitation drying process and spray drying process were compared. Compared with the traditional preparation method, the extract prepared by spray drying had little differences from the polysaccharide content, TLC and the function of reducing TG and TC, and its optimum technology condition were as follows: The inlet air temperature was 180 °C, injection speed was 10 ml/min and crude drugs content was 0. 4 g/mL. Auricularia auricular extract by spray drying technology is stable and feasible with high economic benefit.

  17. Intracoronary thallium-201 assessment of thrombolysis in acute myocardial infarction: a technique for imaging thallium distribution before and after therapy

    International Nuclear Information System (INIS)

    Parker, J.A.; Markis, J.E.; Silverman, K.J.

    1982-01-01

    Intracoronary administration of streptokinase during the acute phase of myocardial infarction results in recanalization of the occluded coronary artery in a high percentage of patients. A technique is developed to investigate the acute effect of thrombolysis on the perfusion to viable myocardium using intracoronary administration of thallium-201. With intracoronary administration a very small initial dose of thallium can be used. Thus, a second scan can be performed after therapy, using a normal dose with only minimal contribution from the baseline study

  18. Ischemic stroke and transient ischemic attack in young adults: risk factors, diagnostic yield, neuroimaging, and thrombolysis.

    Science.gov (United States)

    Ji, Ruijun; Schwamm, Lee H; Pervez, Muhammad A; Singhal, Aneesh B

    2013-01-01

    Approximately 10% to 14% of ischemic strokes occur in young adults. To investigate the yield of diagnostic tests, neuroimaging findings, and treatment of ischemic strokes in young adults. We retrospectively reviewed data from our Get with the Guidelines-Stroke database from 2005 through 2010. University hospital tertiary stroke center. A total of 215 consecutive inpatients aged 18 to 45 years with ischemic stroke/transient ischemic attack. The mean (SD) age was 37.5 (7) years; 51% were male. There were high incidence rates of hypertension (20%), diabetes mellitus (11%), dyslipidemia (38%), and smoking (34%). Relevant abnormalities were shown on cerebral angiography in 136 of 203 patients, on cardiac ultrasonography in 100 of 195, on Holter monitoring in 2 of 192; and on hypercoagulable panel in 30 of 189 patients. Multiple infarcts were observed in 31% and were more prevalent in individuals younger than age 35 years. Relevant arterial lesions were frequently detected in the middle cerebral artery (23%), internal carotid artery (13%), and vertebrobasilar arteries (13%). Cardioembolic stroke occurred in 47% (including 17% with isolated patent foramen ovale), and 11% had undetermined stroke etiology. The median National Institutes of Health Stroke Scale score was 3 (interquartile range, 0-9) and 81% had good outcome at hospital discharge. Of the 29 patients receiving thrombolysis (median National Institutes of Health Stroke Scale score, 14; interquartile range, 9-17), 55% had good outcome at hospital discharge and none developed symptomatic brain hemorrhage. This study shows the contemporary profile of ischemic stroke in young adults admitted to a tertiary stroke center. Stroke etiology can be determined in nearly 90% of patients with modern diagnostic tests. The causes are heterogeneous; however, young adults have a high rate of traditional vascular risk factors. Thrombolysis appears safe and short-term outcomes are favorable.

  19. Factors affecting the occurrence of symptomatic intracerebral haemorrhage after intravenous thrombolysis depending on the haemorrhage definition.

    Science.gov (United States)

    Sledzińska-Dźwigał, M; Sobolewski, Piotr; Szczuchniak, W

    2013-01-01

    Symptomatic intracerebral haemorrhage (sICH) remains the most feared complication of systemic thrombolysis in patients with ischaemic stroke. The aim of the study was to analyze the impact of different factors on the occurrence of sICH, depending on definition used. We retrospectively evaluated the influence of several factors on the occurrence of sICH (according to definitions used in ECASS2, SITS-MOST and NINDS studies) in 200 patients treated with systemic thrombolysis from 2006 to 2011. Multivariate analysis of impact of individual variables on the occurrence of haemorrhagic transformation (HT) and parenchymal haemorrhage type 2 (PH2) were performed. Haemorrhagic transformation occurred in 35 cases (17.5%). SICH was found in 10 cases according to ECASS2, in 7 cases according to SITS and in 13 cases according to NINDS. Older age was related to higher risk of sICH, regardless which definition was used (ECASS2: p = 0.014, SITS-MOST: p = 0.048, NINDS: p = 0.008), and female sex was related to higher risk of sICH according to NINDS and ECASS2 definition (p = 0.002 and p = 0.04, respectively). Blood glucose level and high NIHSS score (> 14 pts) were found as risk factor of sICH in ECASS2 definition (p = 0.044 and p = 0.03, respectively). In multivariate logistic regression higher NIHSS scores were associated with HT independent of age, gender and glucose level (p = 0.012). Multivariate analysis showed no impact of age, gender, severity of stroke and glucose level on presence of PH2. Definition of sICH can determine variables that are related to a high risk of this complication. In our study most factors correlated with sICH using the ECASS2 definition.

  20. Model of the macrostructure formation of plasma sprayed coatings

    International Nuclear Information System (INIS)

    Gnedovets, A.G.; Kalita, V.I.

    2007-01-01

    A 3D discrete ballistic model of plasma sprayed coatings structure formation is presented. The effect of a spraying angle on porous macrostructure of coatings is investigated by numerical computations.Computer simulation results as well as experimental data show that at a sputtering angle less than 45 deg the mechanism of surface relief formation is changed and the relief consists of valleys and ridges under such conditions of plasma spraying [ru

  1. Hydrogen permeation properties of plasma-sprayed tungsten

    International Nuclear Information System (INIS)

    Anderl, R.A.; Pawelko, R.J.; Hankins, M.R.; Longhurst, G.R.; Neiser, R.A.

    1994-01-01

    Tungsten has been proposed as a plasma-facing component material for advanced fusion facilities. This paper reports on laboratory-scale studies that were done to assess the hydrogen permeation properties of plasma-sprayed tungsten for such applications. The work entailed deuterium permeation measurements for plasma-sprayed (PS) tungsten coatings, sputter-deposited (SP) tungsten coatings, and steel substrate material using a mass-analyzed, 3 keV D + 3 ion beam with fluxes of similar 6.5x10 19 D/m 2 s. Extensive characterization analyses for the plasma-sprayed tungsten coatings were made using Auger spectrometry and scanning electron microscopy (SEM). Observed permeation rates through composite PS-tungsten/steel specimens were several orders of magnitude below the permeation levels observed for SP-tungsten/steel composite specimens and pure steel specimens. Characterization analyses indicated that the plasma-sprayed tungsten coating had a nonhomogeneous microstructure that consisted of splats with columnar solidification, partially-melted particles with grain boundaries, and void regions. Reduced permeation levels can be attributed to the complex microstructure and a substantial surface-connected porosity. ((orig.))

  2. Hydrogen permeation properties of plasma-sprayed tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Anderl, R.A. (Idaho National Engineering Lab., EG and G Idaho Inc., Idaho Falls, ID (United States)); Pawelko, R.J. (Idaho National Engineering Lab., EG and G Idaho Inc., Idaho Falls, ID (United States)); Hankins, M.R. (Idaho National Engineering Lab., EG and G Idaho Inc., Idaho Falls, ID (United States)); Longhurst, G.R. (Idaho National Engineering Lab., EG and G Idaho Inc., Idaho Falls, ID (United States)); Neiser, R.A. (Sandia National Laboratories, Albuquerque, NM 87185 (United States))

    1994-09-01

    Tungsten has been proposed as a plasma-facing component material for advanced fusion facilities. This paper reports on laboratory-scale studies that were done to assess the hydrogen permeation properties of plasma-sprayed tungsten for such applications. The work entailed deuterium permeation measurements for plasma-sprayed (PS) tungsten coatings, sputter-deposited (SP) tungsten coatings, and steel substrate material using a mass-analyzed, 3 keV D[sup +][sub 3] ion beam with fluxes of similar 6.5x10[sup 19] D/m[sup 2] s. Extensive characterization analyses for the plasma-sprayed tungsten coatings were made using Auger spectrometry and scanning electron microscopy (SEM). Observed permeation rates through composite PS-tungsten/steel specimens were several orders of magnitude below the permeation levels observed for SP-tungsten/steel composite specimens and pure steel specimens. Characterization analyses indicated that the plasma-sprayed tungsten coating had a nonhomogeneous microstructure that consisted of splats with columnar solidification, partially-melted particles with grain boundaries, and void regions. Reduced permeation levels can be attributed to the complex microstructure and a substantial surface-connected porosity. ((orig.))

  3. Metallization of Various Polymers by Cold Spray

    Science.gov (United States)

    Che, Hanqing; Chu, Xin; Vo, Phuong; Yue, Stephen

    2018-01-01

    Previous results have shown that metallic coatings can be successfully cold sprayed onto polymeric substrates. This paper studies the cold sprayability of various metal powders on different polymeric substrates. Five different substrates were used, including carbon fiber reinforced polymer (CFRP), acrylonitrile butadiene styrene (ABS), polyether ether ketone (PEEK), polyethylenimine (PEI); mild steel was also used as a benchmark substrate. The CFRP used in this work has a thermosetting matrix, and the ABS, PEEK and PEI are all thermoplastic polymers, with different glass transition temperatures as well as a number of distinct mechanical properties. Three metal powders, tin, copper and iron, were cold sprayed with both a low-pressure system and a high-pressure system at various conditions. In general, cold spray on the thermoplastic polymers rendered more positive results than the thermosetting polymers, due to the local thermal softening mechanism in the thermoplastics. Thick copper coatings were successfully deposited on PEEK and PEI. Based on the results, a method is proposed to determine the feasibility and deposition window of cold spraying specific metal powder/polymeric substrate combinations.

  4. Current situation and development tendency of thermal spraying materials in China

    Institute of Scientific and Technical Information of China (English)

    YU; Yue-guang

    2005-01-01

    The current situations of thermal spraying materials in China are described in this paper.The thermal spraying technology in China has a great progress over tens of years. More than one hundred varieties of material products serve thermal spraying producing now. They belong to three kinds, powders,wires and rods. Technologies for producing alloy, ceramic and composite powders, alloy and cored wires,and oxide ceramic rods are applied to large-scale production. Many research and development works on advanced materials for thermal spraying are carrying out recent years. They show that the general tendencies of thermal spraying materials in China are composite or low-impurity component, ultrafine or nanosized microstructure, high properties, and specialized and systematized applications. Thermal spraying materials have great prospects with the development of saving society in China.

  5. Spray Drying of Mosambi Juice in Lab

    Science.gov (United States)

    Singh, S. V.; Verma, A.

    2014-01-01

    The studies on spray drying of mosambi juice were carried out with Laboratory spray dryer set-up (LSD-48 MINI SPRAY DRYER-JISL). Inlet and outlet air temperature and maltodextrin (drying agent) concentration was taken as variable parameters. Experiments were conducted by using 110 °C to 140 °C inlet air temperature, 60 °C to 70 °C outlet air temperature and 5-7 % maltodextrin concentration. The free flow powder of mosambi juice was obtained with 7 % maltodextrin at 140 °C inlet air temperature and 60 °C outlet air temperature. Fresh and reconstituted juices were evaluated for vitamin C, titrable acidity and sensory characteristics. The reconstituted juice was found slightly acceptable by taste panel.

  6. Spray-formed tooling

    Science.gov (United States)

    McHugh, K. M.; Key, J. F.

    The United States Council for Automotive Research (USCAR) has formed a partnership with the Idaho National Engineering Laboratory (INEL) to develop a process for the rapid production of low-cost tooling based on spray forming technology developed at the INEL. Phase 1 of the program will involve bench-scale system development, materials characterization, and process optimization. In Phase 2, prototype systems will be designed, constructed, evaluated, and optimized. Process control and other issues that influence commercialization will be addressed during this phase of the project. Technology transfer to USCAR, or a tooling vendor selected by USCAR, will be accomplished during Phase 3. The approach INEL is using to produce tooling, such as plastic injection molds and stamping dies, combines rapid solidification processing and net-shape materials processing into a single step. A bulk liquid metal is pressure-fed into a de Laval spray nozzle transporting a high velocity, high temperature inert gas. The gas jet disintegrates the metal into fine droplets and deposits them onto a tool pattern made from materials such as plastic, wax, clay, ceramics, and metals. The approach is compatible with solid freeform fabrication techniques such as stereolithography, selective laser sintering, and laminated object manufacturing. Heat is extracted rapidly, in-flight, by convection as the spray jet entrains cool inert gas to produce undercooled and semi-solid droplets. At the pattern, the droplets weld together while replicating the shape and surface features of the pattern. Tool formation is rapid; deposition rates in excess of 1 ton/h have been demonstrated for bench-scale nozzles.

  7. Successful treatment of central venous catheter induced superior vena cava syndrome with ultrasound accelerated catheter-directed thrombolysis.

    Science.gov (United States)

    Dumantepe, Mert; Tarhan, Arif; Ozler, Azmi

    2013-06-01

    Superior vena cava (SVC) syndrome results from obstruction of flow through the vessel either by external compression or thrombosis. External compression by intrathoracic neoplasms is the most common etiology, especially lung cancer and lymphoma. Thrombosis is becoming increasingly common due to the use of indwelling catheters and implantable central venous access devices. Most patients are unresponsive to anticoagulation alone which appears to be effective only in the mildest cases. However, recent advances in catheter-based interventions have led to the development of a variety of minimally invasive endovascular strategies to remove venous thrombus and accepted as an important first-line treatment given its high overall success rate and low morbidity as compared with medical and surgical treatments. Ultrasound accelerated catheter-directed thrombolysis (UACDT) has been developed to rapidly and completely resolve the existing thrombus. This technique integrates high frequency, low intensity ultrasound (US) with standard CDT in order to accelerate clot dissolution, reducing treatment time and the incidence of thrombolysis-related complications. An US wave enhances drug permeation through thrombus by disaggregating the fibrin matrix, exposing additional plasminogen receptor sites to the thrombolytic agent. The US energy affects thrombus in the entire venous segment, increasing the probability of complete thrombus clearing. We report the case of a 56-year-old man who presented with a 5 days history of SVC syndrome symptoms who had been receiving chemotherapy for colon cancer through a right subclavian vein port catheter. The patient successfully treated with UACDT with EkoSonic(®) Mach4e Endovascular device with an overnight infusion. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  8. Elastic response of thermal spray deposits under indentation tests

    International Nuclear Information System (INIS)

    Leigh, S.H.; Lin, C.K.; Berndt, C.C.

    1997-01-01

    The elastic response behavior of thermal spray deposits at Knoop indentations has been investigated using indentation techniques. The ration of hardness to elastic modulus, which is an important prerequisite for the evaluation of indentation fracture toughness, is determined by measuring the elastic recovery of the in-surface dimensions of Knoop indentations. The elastic moduli of thermal spray deposits are in the range of 12%--78% of the comparable bulk materials and reveal the anisotropic behavior of thermal spray deposits. A variety of thermal spray deposits has been examined, including Al 2 O 3 , yttria-stabilized ZrO 2 (YSZ), and NiAl. Statistical tools have been used to evaluate the error estimates of the data

  9. Quantitative and economical assessment of effectiveness of electrostatic pesticide spraying

    International Nuclear Information System (INIS)

    Nishimura, Ryo; Fujita, Satoko; Michihara, Shota; Masuoka, Takashi; Kimura, Toshihiro; Yatsuzuka, Shinji; Anaguchi, Shinobu

    2013-01-01

    Electrostatic pesticide spraying (EPS) improves the adhesion characteristics of the pesticide solution to agricultural crops. If the adhesion characteristics are improved, the requisite amount of the pesticide to be sprayed can be reduced in comparison with the conventional spraying method that uses non-charged pesticide. In this research, disease (rust) control experiments were carried out to substantiate the effectiveness of the EPS from a statistical point of view. We sprayed pesticide to potted Japanese pear trees under calm condition. The numbers of the rust lesions on the pear leaves were counted at fixed intervals after spraying to investigate the difference of the results of the disease control. The t-tests were carried out for the populations of the various spraying times and applied voltages. It was statistically-derived that EPS can reduce the amounts of pesticide to be sprayed by 50 % in comparison with the non-EPS method. It is also estimated from the results that about 55,000 kL year −1 of pesticides can be reduced for the Japanese pear cultivation in Tottori prefecture. Also, this means that the expense of the pear cultivation can be reduced by about 240 million yen (3 million USD) every year in Tottori prefecture by introducing EPS.

  10. Hard tissue ablation with a spray-assisted mid-IR laser

    International Nuclear Information System (INIS)

    Kang, H W; Rizoiu, I; Welch, A J

    2007-01-01

    The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment

  11. Hard tissue ablation with a spray-assisted mid-IR laser

    Science.gov (United States)

    Kang, H. W.; Rizoiu, I.; Welch, A. J.

    2007-12-01

    The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment.

  12. Plasma spraying of refractory metals and refractory hard materials. State of the art

    International Nuclear Information System (INIS)

    Eschnauer, H.; Lugscheider, E.; Jaeger, D.

    1989-01-01

    Suitable spraying processes for manufacturing refractory metals, refractory hard materials as well as spray materials with refractory components are the VPS- and IPS-spraying techniques. The advantages of these special spraying process variations are described. The reactive spraying materials are systematically organized. The characteristical properties used in purpose of improving the substrate surfaces are explained. Finally some examples of the latest results of research concerning plasma spraying of reactive materials are shown. 16 refs., 10 figs. (Author)

  13. Influence of fuel temperature on dispersion and decay of BDE sprays; Einfluss der Kraftstofftemperatur auf die Ausbreitung und den Zerfall von BDE-Sprays

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, I.; Beyrau, F.; Leipertz, A. [Erlangen-Nuernberg Univ., Erlangen (Germany). Lehrstuhl fuer Technische Thermodynamik

    2007-07-01

    As an example for a highly - developed technical spray system, the spray vaporization of a multi - hole injector used for the gasoline direct injection (GDI) has been investigated. Experiments were conducted in a heated injection chamber for different chamber pressures, fuels and fuel temperatures. In this investigation pure rotational coherent anti-Stokes Raman spectroscopy (RCARS) has been applied to the study of vaporizing sprays in combination with other laser techniques. Gas phase temperatures inside the sprays have been determined with high spatial and temporal resolution. A temperature drop of about 30 K was measured for all fuel temperatures studied. Droplet sizes and number densities have been measured using phase Doppler anemometry, and the correlation of these results with two - dimensional laser sheet Mie scattering images and laser-induced exciplex fluorescence allows an improved interpretation of the spray vaporization process. Furthermore under the influence of flash boiling a reduction of the mean drop size D10 up to 30% could be observed. (orig.)

  14. Summary of the Blackmo 88 spray experiment

    Science.gov (United States)

    D. R. Miller; W. E. Yendol; M. L. McManus; D. E. Anderson; K. Mierzejewski

    1991-01-01

    The Blackmo 88 spray trial experiment was conducted for two primary purposes: To quantify the effects of local micrometeorological processes, in and near the canopy, on the deposition patterns of aerially applied BT in a mature oak forest; To generate a data set containing simultaneous measurements of spray deposition and detailed micrometeorology, in a canopy of known...

  15. Gene Expression, Bacteria Viability and Survivability Following Spray Drying of Mycobacterium smegmatis

    Directory of Open Access Journals (Sweden)

    Elizabeth Hunter Lauten

    2010-04-01

    Full Text Available We find that Mycobacterium smegmatis survives spray drying and retains cell viability in accelerated temperature stress (40 °C conditions with a success rate that increases with increasing thermal, osmotic, and nutrient-restriction stresses applied to the mycobacterium prior to spray drying. M.smegmatis that are spray dried during log growth phase, where they suffer little or no nutrient-reduction stress, survive for less than 7 days in the dry powder state at accelerated temperature stress conditions, whereas M. smegmatis that are spray dried during stationary phase, where cells do suffer nutrient reduction, survive for up to 14 days. M. smegmatis that are spray dried from stationary phase, subjected to accelerated temperature stress conditions, regrown to stationary phase, spray dried again, and resubmitted to this same process four consecutive times, display, on the fourth spray drying iteration, an approximate ten-fold increase in stability during accelerated temperature stress testing, surviving up to 105 days. Microarray tests revealed significant differences in genetic expression of M. smegmatis between log phase and stationary phase conditions, between naïve (non spray-dried and multiply cycled dried M. smegmatis (in log and stationary phase, and between M. smegmatis in the dry powder state following a single spray drying operation and after four consecutive spray drying operations. These differences, and other phenotypical differences, point to the carotenoid biosynthetic pathway as a probable pathway contributing to bacteria survival in the spray-dried state and suggests strategies for spray drying that may lead to significantly greater room-temperature stability of mycobacteria, including mycobacterium bovis bacille Calmette-Guerin (BCG, the current TB vaccine.

  16. Optimization of spray deposition and Tetranychus urticae control with air assisted and electrostatic sprayer

    Directory of Open Access Journals (Sweden)

    Denise Tourino Rezende de Cerqueira

    Full Text Available ABSTRACT: Improved spray deposition can be attained by electrostatically charging spray droplets, which increases the attraction of droplets to plants and decreases operator exposure to pesticide and losses to the environment. However, this technique alone is not sufficient to achieve desirable penetration of the spray solution into the crop canopy; thus, air assistance can be added to the electrostatic spraying to further improve spray deposition. This study was conducted to compare different spraying technologies on spray deposition and two-spotted spider mite control in cut chrysanthemum. Treatments included in the study were: conventional TJ 8003 double flat fan nozzles, conventional TXVK-3 hollow cone nozzles, semi-stationary motorized jet launched spray with electrostatic spray system (ESS and air assistance (AA, and semi-stationary motorized jet launched spray with AA only (no ESS. To evaluate the effect of these spraying technologies on the control of two-spotted spider mite, a control treatment was included that did not receive an acaricide application. The AA spraying technology, with or without ESS, optimized spray deposition and provided satisfactory two-spotted spider mite control up to 4 days after application.

  17. Release mitigation spray safety systems for chemical demilitarization applications.

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jonathan; Tezak, Matthew Stephen; Brockmann, John E.; Servantes, Brandon; Sanchez, Andres L.; Tucker, Mark David; Allen, Ashley N.; Wilson, Mollye C.; Lucero, Daniel A.; Betty, Rita G.

    2010-06-01

    Sandia National Laboratories has conducted proof-of-concept experiments demonstrating effective knockdown and neutralization of aerosolized CBW simulants using charged DF-200 decontaminant sprays. DF-200 is an aqueous decontaminant, developed by Sandia National Laboratories, and procured and fielded by the US Military. Of significance is the potential application of this fundamental technology to numerous applications including mitigation and neutralization of releases arising during chemical demilitarization operations. A release mitigation spray safety system will remove airborne contaminants from an accidental release during operations, to protect personnel and limit contamination. Sandia National Laboratories recently (November, 2008) secured funding from the US Army's Program Manager for Non-Stockpile Chemical Materials Agency (PMNSCMA) to investigate use of mitigation spray systems for chemical demilitarization applications. For non-stockpile processes, mitigation spray systems co-located with the current Explosive Destruction System (EDS) will provide security both as an operational protective measure and in the event of an accidental release. Additionally, 'tented' mitigation spray systems for native or foreign remediation and recovery operations will contain accidental releases arising from removal of underground, unstable CBW munitions. A mitigation spray system for highly controlled stockpile operations will provide defense from accidental spills or leaks during routine procedures.

  18. Production of press moulds by plasma spray forming process

    International Nuclear Information System (INIS)

    Borisov, Y.; Myakota, I.; Polyakov, S.

    2001-01-01

    Plasma spray forming process for production of press moulds which are used for manufacture of articles from plastics was developed. The press moulds were produced by plasma spraying of Cu-Al-Fe-alloy powder on surface of a master model. The master models were made from non-metallic materials with heat resistance below 70 C (wood, gypsum etc). Double cooling system which provides for a control of surface model temperature and quenching conditions of sprayed material was designed. It made possible on the one hand to support model surface temperature below 70 C and on the other hand to provide for temperature conditions of martensite transformation in Cu-Al-system with a fixation of metastable ductile α + β 1 -phase. This allowed to decrease residual stresses in sprayed layer (up to 0,5-2,5 MPa), to increase microhardness of the coating material (up to 1200-1800 MPa) and its ductility (σ B = 70-105 MPa, δ = 6-12 %). This plasma spray forming process makes possible to spray thick layers (5-20 mm and more) without their cracking and deformation. The process is used for a production of press moulds which are applied in shoes industry, for fabrication of toys, souvenirs etc. (author)

  19. Heat removal tests for pressurized water reactor containment spray by largescale facility

    International Nuclear Information System (INIS)

    Motoki, Y.; Hashimoto, K.; Kitani, S.; Naritomi, M.; Nishio, G.; Tanaka, M.

    1983-01-01

    Heat removal tests for pressurized water reactor (PWR) containment spray were carried out to investigate effectiveness of the depressurization by Japan Atomic Energy Research Institute model containment (7-m diameter, 20 m high, and 708-m 3 volume) with PWR spray nozzles. The depressurization rate is influenced by the spray heat transfer efficiency and the containment wall surface heat transfer coefficient. The overall spray heat transfer efficiency was investigated with respect to spray flow rate, weight ratio of steam/air, and spray height. The spray droplet heat transfer efficiency was investigated whether the overlapping of spray patterns gives effect or not. The effect was not detectable in the range of large value of steam/air, however, it was better in the range of small value of it. The experimental results were compared with the calculated results by computer code CONTEMPT-LT/022. The overall spray heat transfer efficiency was almost 100% in the containment pressure, ranging from 2.5 to 0.9 kg/cm 2 X G, so that the code was useful on the prediction of the thermal hydraulic behavior of containment atmosphere in a PWR accident condition

  20. Development of construction methods for high-density bentonite barriers using premixed spraying. Part 1. Laboratory tests on methods of spraying roughly crushed bentonite and investigation of mixing methods

    International Nuclear Information System (INIS)

    Kobayashi, Ichizo; Tanaka, Toshiyuki; Nakajima, Makoto; Toida, Masaru

    2006-01-01

    According to the present concept of geological disposal of radioactive waste, a disposal facility should consist of a bentonite-engineered barrier, a cementitious-engineered barrier, and natural barriers. To guarantee the validity of the geological disposal concept, the bentonite-engineered barrier must have high impermeability. However, an effective construction method for high-density bentonite-engineered barriers in narrow spaces such as those in radioactive waste geological disposal sites has not been developed. Therefore, the authors have developed a spraying method that has high workability in narrow spaces as a method of constructing bentonite-engineered barriers in narrow spaces. This paper describes the production method for a spraying material and an examination through spraying tests of the spraying distance, the shapes of the spray nozzles, and the ratio of spraying material to air. The test results confirmed that a bentonite-engineered barrier of dry density 1.6 Mg/m 3 could be constructed using the spraying method developed and that the appropriate spraying conditions for the construction of high-density bentonite barriers were obtained. Moreover, the authors developed a construction quality management method using the silicon oil specific-gravity method that can clearly and promptly indicate the dry density of the sprayed bentonite. (author)