  1. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  2. Downhole pulse tube refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.; Gardner, D. [Los Alamos National Lab., NM (United States). Condensed Matter and Thermal Physics Group

    1997-12-01

    This report summarizes a preliminary design study to explore the plausibility of using pulse tube refrigeration to cool instruments in a hot down-hole environment. The original motivation was to maintain Dave Reagor`s high-temperature superconducting electronics at 75 K, but the study has evolved to include three target design criteria: cooling at 30 C in a 300 C environment, cooling at 75 K in a 50 C environment, cooling at both 75 K and 30 C in a 250 C environment. These specific temperatures were chosen arbitrarily, as representative of what is possible. The primary goals are low cost, reliability, and small package diameter. Pulse-tube refrigeration is a rapidly growing sub-field of cryogenic refrigeration. The pulse tube refrigerator has recently become the simplest, cheapest, most rugged and reliable low-power cryocooler. The authors expect this technology will be applicable downhole because of the ratio of hot to cold temperatures (in absolute units, such as Kelvin) of interest in deep drilling is comparable to the ratios routinely achieved with cryogenic pulse-tube refrigerators.

  3. Pulse tube refrigerator; Parusukan reitoki

    Energy Technology Data Exchange (ETDEWEB)

    Hozumi, Yoshikazu [University of Tsukuba, Tsukuba (Japan); Shiraishi, Masao [Hiroshima University, Hiroshima (Japan)

    1999-06-05

    In the cryogenic field, high temperature superconductivity and research and development of the peripheral technology are popular. Refrigerating machine development of the very low temperature is also one of the results. Research and development are mainly advanced as a refrigerating machine of the center for the aerospace plane installation. There is special and small very low temperature refrigerating machine called 'the pulse tube refrigerating machine' of which the practical application is also recently being attempted for the semiconductor cooling using high temperature superconductivity. At present, the basic research of elucidation of refrigeration phenomenon of pulse tube refrigerating machine and development of high-performance pulse tube refrigerating machine is carried out by experiment in the Ministry of International Trade and Industry Mechanical Engineering Lab., Agency of Industrial Sci. and Technology and numerical simulation in Chiyoda Corp. In this report, the pulse tube refrigerating machine is introduced, and the application in the chemical engineering field is considered. (NEDO)

  4. A review of pulse tube refrigeration

    Science.gov (United States)

    Radebaugh, Ray

    This paper reviews the development of the three types of pulse tube refrigerators: basic, resonant, and orifice types. The principles of operation are given. It is shown that the pulse tube refrigerator is a variation of the Stirling-cycle refrigerator, where the moving displacer is substituted by a heat transfer mechanism or by an orifice to bring about the proper phase shifts between pressure and mass flow rate. A harmonic analysis with phasors is described which gives reasonable results for the refrigeration power, yet is simple enough to make clear the processes which give rise to the refrigeration. The efficiency and refrigeration power are compared with those of other refrigeration cycles. A brief review is given of the research being done at various laboratories on both one- and two-stage pulse tubes. A preliminary assessment of the role of pulse tube refrigerators is discussed.

  5. Optimizing the Thermoacoustic Pulse Tube Refrigerator Performances

    Directory of Open Access Journals (Sweden)

    E. V. Blagin

    2014-01-01

    Full Text Available The article deals with research and optimization of the thermoacoustic pulse tube refrigerator to reach a cryogenic temperature level. The refrigerator is considered as a thermoacoustic converter based on the modified Stirling cycle with helium working fluid. A sound pressure generator runs as a compressor. Plant model comprises an inner heat exchanger, a regenerative heat exchanger, a pulse tube, hot and cold heat exchangers at its ends, an inertial tube with the throttle, and a reservoir. A model to calculate the pulse tube thermoacoustic refrigerator using the DeltaEC software package has been developed to be a basis for calculation techniques of the pulse tube refrigerator. Momentum, continuity, and energy equations for helium refrigerant are solved according to calculation algorithm taking into account the porosity of regenerator and heat exchangers. Optimization of the main geometric parameters resulted in decreasing temperature of cold heat exchanger by 41,7 K. After optimization this value became equal to 115,01 K. The following parameters have been optimized: diameters of the feeding and pulse tube and heat exchangers, regenerator, lengths of the regenerator and pulse and inertial tubes, as well as initial pressure. Besides, global minimum of temperatures has been searched at a point of local minima corresponding to the optimal values of abovementioned parameters. A global-local minima difference is 0,1%. Optimized geometric and working parameters of the thermoacoustic pulse tube refrigerator are presented.

  6. Performance characteristics of pulse tube refrigerators

    Science.gov (United States)

    Huang, B. J.; Tzeng, T. M.

    In the present study experiments were carried out to investigate the performance characteristics of pulse tube refrigerators. It was found that the cool-down time tc during the transient or start-up period is dominated by the time constant of the pulse tube wall τpt and that the dynamics of a basic pulse tube (BPT) refrigerator approaches that of a first-order system. For steady state operation, the cold-end temperature TL was found to vary with τpt, and the cooling load QL increases monotonically with increasing τpt. This indicates that heat pumped by the gas from the cold to the hot end increases with decreasing hpt (i.e. less energy exchange between the gas and wall). The process of heat storage or release of the pulse tube wall is thus shown to have a negative effect on the performance of a BPT refrigerator. It was thus found experimentally that the gas compression/expansion process inside the pulse tube, which is similar to a Brayton cycle but lies between isothermal and adiabatic, can explain the performance of BPT refrigerators. The present experiment also shows that the performance of a pulse tube refrigerator at transient and steady states is mainly dominated by the time constant of the pulse tube wall τpt.

  7. 92 K thermoacoustically driven pulse tube refrigerator

    Institute of Scientific and Technical Information of China (English)

    TANG Ke; CHEN Guobang; JIN Tao; KONG Bo; BAO Rui; QIU Limin; GAN Zhihua

    2004-01-01

    @@ A thermoacoustic prime mover, instead of a mechanical compressor, was firstly proposed in 1990 by Radebaugh and Swift et al. to drive a pulse tube refrigerator [1]. The so-called thermoacoustically driven pulse tube refrigerator (TADPTR) has a number of advantages. First,it is characterized by its long-term stable operation for it has no moving components. Besides, solar energy and waste fuel gas can be adopted as its driving source. Utilization of low-grade energy not only improves its overall thermal efficiency, but also is most attractively applicable to the case which is short of electricity but abundant in heat energy. The potential applications, such as thermoacoustic natural gas liquefier, are under development[2].It burns part of natural gas to drive a pulse tube refrigerator whose cooling capacity is then used to liquefy the rest natural gas.

  8. Investigation of active-buffer pulse tube refrigerator

    Science.gov (United States)

    Zhu, Shaowei; Kakimi, Yasuhiro; Matsubara, Yoichi

    An active-buffer pulse tube refrigerator, which is a GM type pulse tube refrigerator, is described in this paper. Two or more buffers are connected at the hot end of the pulse tube through on/off valves. The main purpose of this method is to increase the efficiency. A numerical method is introduced to analyse the working process. To understand the basic mechanism, an ideal cycle is also introduced. With a prototype single stage active-buffer pulse tube refrigerator, a cooling capacity of 166 W and a percent Carnot of 13% at 80 K have been obtained.

  9. Approximate Design Method for Single Stage Pulse Tube Refrigerators

    Science.gov (United States)

    Pfotenhauer, J. M.; Gan, Z. H.; Radebaugh, R.

    2008-03-01

    An approximate design method is presented for the design of a single stage Stirling type pulse tube refrigerator. The design method begins from a defined cooling power, operating temperature, average and dynamic pressure, and frequency. Using a combination of phasor analysis, approximate correlations derived from extensive use of REGEN3.2, a few `rules of thumb,' and available models for inertance tubes, a process is presented to define appropriate geometries for the regenerator, pulse tube and inertance tube components. In addition, specifications for the acoustic power and phase between the pressure and flow required from the compressor are defined. The process enables an appreciation of the primary physical parameters operating within the pulse tube refrigerator, but relies on approximate values for the combined loss mechanisms. The defined geometries can provide both a useful starting point, and a sanity check, for more sophisticated design methodologies.

  10. Experimental results on V-M type pulse tube refrigerator

    Science.gov (United States)

    Dai, Wei; Matsubara, Yoichi; Kobayashi, Hisayasu

    2002-06-01

    This article mainly introduces experimental results on a new type pulse tube refrigerator named as V-M type pulse tube refrigerator. The main difference from Stirling type or G-M type pulse tube refrigerator is that thermal compressor similar to that of a V-M cryocooler is used instead of mechanical compressor. By using temperature difference between room temperature and liquid nitrogen, pressure wave with high to low pressure ratio around 1.2 is obtained. This pressure wave is used to generate cooling effect at the cold end. With a 20 K pre-cooler, this machine reaches lowest temperature 5.25 K by using helium 4 at 0.77 Hz, 19 bar charge pressure. DC flow plays an important role in our system. It not only influences the final obtainable lowest temperature, but also is used to increase cold end cool-down speed. Total volume of the V-M type pulse tube refrigerator is around 3.3 l. However, dead volume inside rotor housing occupies about 2.8 l and can be much reduced.

  11. High-frequency Pulse-tube Refrigerator for 4 K

    Science.gov (United States)

    Tanaeva, I. A.; Klaasse Bos, C. G.; de Waele, A. T. A. M.

    2006-04-01

    At present pulse-tube refrigerators (PTRs), used for the important temperature region of 4 K, are of the Gifford-McMahon (GM)-type. The main sources of losses in GM-type PTRs are the compressor and the rotary valve. The efficiency of the combination of the compressor and the rotary valve is only about 30%. In addition to that GM-type compressors are heavy and need periodic maintenance. The main goal of this research is to develop a Stirling-type 4-K pulse-tube refrigerator. This implies higher operating frequencies, compared to the usual 1-2 Hz. At higher frequencies a number of properties of a pulse-tube system, such as length-to-diameter ratios of the pulse tubes and the regenerator, volume and configuration of a regenerator material, phase-shift control method, etc., change significantly, and, therefore, require detailed study. The interactions between various parameters of the pulse tube and of the linear compressor are very complicated. Therefore, as a first part of this research, we study the pulse tube at high frequencies, independent of the compressor. We generate high-frequency pressure oscillations, using a GM-type compressor and a special type of rotary valve, which enables us to operate at frequencies up to 20 Hz. Results of this work are described in this contribution.

  12. Analysis of basic pulse-tube refrigerator with regenerator

    Science.gov (United States)

    de Boer, P. C. T.

    A previously presented thermodynamic analysis of the basic pulse-tube refrigerator is extended to the case with a regenerator. In this case there is a heat exchanger at the warm end of the regenerator, in addition to the cold and warm heat exchangers at the ends of the pulse tube. The analysis is based on a four-step cycle: adiabatic compression of the gas in the pulse tube; isobaric heat transfer from the gas to the wall of the pulse tube; adiabatic expansion of the gas in the pulse tube; and isobaric heat transfer from the wall of the pulse tube to the gas. The pressure is taken to be uniform during the entire cycle. Gas elements inside the regenerator are assumed to be at the local temperature of the regenerator. The performance of the regenerator and its adjacent heat exchangers is investigated using control volume analysis to determine enthalpy flows, and by control mass analysis to determine heat flows associated with individual gas elements. The mechanism by which heat is transported from the cold end to the warm end of the regenerator is discussed. The addition of the regenerator is found to yield significant improvements in the heat removed per cycle, the coefficient of performance and the refrigeration efficiency. Detailed results for these quantities are presented as a function of the temperature ratio of the heat exchangers.

  13. Numerical simulation of a step-piston type series two-stage pulse tube refrigerator

    Science.gov (United States)

    Zhu, Shaowei; Nogawa, Masafumi; Inoue, Tatsuo

    2007-09-01

    A two-stage pulse tube refrigerator has a great advantage in that there are no moving parts at low temperatures. The problem is low theoretical efficiency. In an ordinary two-stage pulse tube refrigerator, the expansion work of the first stage pulse tube is rather large, but is changed to heat. The theoretical efficiency is lower than that of a Stirling refrigerator. A series two-stage pulse tube refrigerator was introduced for solving this problem. The hot end of the regenerator of the second stage is connected to the hot end of the first stage pulse tube. The expansion work in the first stage pulse tube is part of the input work of the second stage, therefore the efficiency is increased. In a simulation result for a step-piston type two-stage series pulse tube refrigerator, the efficiency is increased by 13.8%.

  14. Thermodynamic analysis of the basic pulse-tube refrigerator

    Science.gov (United States)

    de Boer, P. C. T.

    The basic pulse-tube refrigerator is modelled as a tube with one end closed and with a movable piston at the other end. Both ends contain heat exchangers. The piston is capable of moving through the heat exchanger at its end. The thermodynamic model consists of four steps: adiabatic compression of the gas in the pulse tube; isobaric heat transfer from the gas to the wall of the pulse tube; adiabatic expansion of the gas in the pulse tube; and isobaric heat transfer from the wall of the pulse tube to the gas. During the entire cycle the pressure is taken to be uniform, and the gas inside either heat exchanger is assumed to be at the temperature of that exchanger. Upon neglecting gas motion during the isobaric heat transfer steps, complete analytical results are obtained for the temperature profiles of the wall, of the gas after compression, and of the gas after expansion. Each of these profiles is piecewise adiabatic. The profiles are used in finding the coefficient of performance and the net work done per cycle. The coefficient of performance is derived by noting that the basic heat transfer process consists of several reverse Brayton cycles, staged in series. The net work done per cycle is found by constructing the p-V diagram for the piston. This diagram represents a modified reverse Brayton cycle, with each of the compression and expansion steps consisting of two hyperbolic segments. The parameters determining these segments depend on the temperature at which gas enters the heat exchangers. Results are presented for the coefficient of performance and the heat removed per cycle as a function of the temperature ratio of the heat exchangers, for various values of the pressure ratio π and the non-dimensional length Lh of the heat exchanger at the closed end. The model is non-linear and permits study of the effect of large values of π and Lh.

  15. Dynamic Experimental Study of a Multi—bypass Pulse Tube Refrigerator with Two—bypass Tubes

    Institute of Scientific and Technical Information of China (English)

    YonglinJu; ChaoWang; 等

    1998-01-01

    A dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multibypass pulse tube refrigerator(MPTR) was designed and constructed.Some important experimental results of the instantaneous measurements of the velocity and the pressure in the MPTR with twobypass tubes during actual operation are prsented.The effects of the middle-bypass version on the dynamic pressure and mass flow rate at the cold end of the pulse tube are ev aluated from experimental measurements.DC-flow phenomena are observed in this MPTR.The reasons of the multi-bypass version improved the performance of pulse tube refrigertor are given.

  16. A pulse-tube refrigerator using variable-resistance orifice

    Science.gov (United States)

    Huang, B. J.; Sun, B. W.

    2003-01-01

    In the present study, we propose a new design of orifice pulse-tube refrigerator (VROPT) using a variable-resistance valve to replace the conventional orifice. The variable-resistance orifice (VRO) is basically a high-speed solenoidal valve similar to the fuel jet device widely used in automobile engines. By changing the frequency and periods of ON and OFF of the valve through an electronic device, we can change the flow resistance of the VRO. This thus provides a possibility for an OPT to be controlled on-line during operation. From the results obtained in the present study, we have shown that VROPT is able to achieve on-line control by regulating the duty cycle d or frequency fv of the VRO. We also show that VROPT will not loss its thermal performance as compared to conventional OPT.

  17. Tandem GM Type-Pulse Tube Refrigerator with Novel Rotary Valve and Bypass Valve Mechanism

    Science.gov (United States)

    Jung, J.; Jeong, S.; Kwon, Y.; Sohn, M.

    2006-04-01

    A single-stage tandem pulse tube refrigerator has been fabricated, which is driven by two pulsating pressures of opposite phase. The refrigerator is designed as the first stage machine of a 4 K pulse tube refrigerator using a recuperator as the second stage regenerator. In this tandem configuration, two pressure pulsations are generated by a single GM-cryocooler compressor. Two identical pulse tube refrigerators are operated with a novel rotary valve that can supply high and low pressures simultaneously. The pressure measurement at the regenerator inlets of the pulse tube refrigerators confirmed the proper pressure wave of two pulsating pressures in opposite phase. Detrimental DC-flow characteristic of double-inlet GM-type pulse tube refrigerator has been suppressed by the newly designed bypass valve mechanism. This new bypass valve set has one more extra degree of freedom than usual ones to eliminate DC-flow easily. This paper describes a novel feature of the bypass valve set and its performance in the experiment. The two twin pulse tube refrigerators in a tandem mode respectively reached 35 K at no load.

  18. Three-dimensional numerical simulation of the basic pulse tube refrigerator

    Institute of Scientific and Technical Information of China (English)

    Wenjing DING; Liang GONG; Yaling HE; Wenquan TAO

    2008-01-01

    A three-dimensional physical and numerical model of the basic pulse tube refrigerator (PTR) was developed. The compressible and oscillating fluid flow and heat transfer phenomenon in the pulse tube were numerically investigated using a self-developed code. Some cross-section average parameter variations such as velocity, temperature and pressure wave during one cycle were revealed. The variations of velocity and temperature distributions in the pulse tube were also analyzed in detail for further understanding of the working process and refrigeration mechanism of PTRs.

  19. Influence of the Water-Cooled Heat Exchanger on the Performance of a Pulse Tube Refrigerator

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2017-02-01

    Full Text Available The water-cooled heat exchanger is one of the key components in a pulse tube refrigerator. Its heat exchange effectiveness directly influences the cooling performance of the refrigerator. However, effective heat exchange does not always result in a good performance, because excessively reinforced heat exchange can lead to additional flow loss. In this paper, seven different water-cooled heat exchangers were designed to explore the best configuration for a large-capacity pulse tube refrigerator. Results indicated that the heat exchanger invented by Hu always offered a better performance than that of finned and traditional shell-tube types. For a refrigerator with a working frequency of 50 Hz, the best hydraulic diameter is less than 1 mm.

  20. Advances in thermoacoustic engine and its application to pulse tube refrigeration

    Institute of Scientific and Technical Information of China (English)

    CHEN Guobang; TANG Ke; JIN Tao

    2004-01-01

    Thermoacoustically driven pulse tube refrigerator, a novel cryocooler without any moving components using heat energy as driving power, attracts much efforts from the researchers in the field of cryogenics and refrigeration in the past decades. After a short introduction of the history about thermoacoustics, we presented the key technology, followed by a detailed review on theoretical and experimental developments and advances of thermoacoustics.The prospective research emphases are also presented at the end of this review.

  1. Method and apparatus for fine tuning an orifice pulse tube refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Swift, Gregory W.; Wollan, John J.

    2003-12-23

    An orifice pulse tube refrigerator uses flow resistance, compliance, and inertance components connected to a pulse tube for establishing a phase relationship between oscillating pressure and oscillating velocity in the pulse tube. A temperature regulating system heats or cools a working gas in at least one of the flow resistance and inertance components. A temperature control system is connected to the temperature regulating system for controlling the temperature of the working gas in the at least one of the flow resistance and inertance components and maintains a control temperature that is indicative of a desired temporal phase relationship.

  2. 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator

    Institute of Scientific and Technical Information of China (English)

    TANG Ke; CHEN Guobang; THUMMES Günter

    2005-01-01

    Stirling-type pulse tube refrigerators have attracted academic and commercial interest in recent years due to their more compact configuration and higher efficiency than those of G-M type pulse tube refrigerators. In order to achieve a no-load cooling temperature below 20 K, a thermally coupled two-stage Stirling-type pulse tube refrigerator has been built. The thermally coupled arrangement was expected to minimize the interference between the two stages and to simplify the adjustment and optimization of the phase shifters. A no-load cooling temperature of 14.97 K has been realized with the two-stage cooler driven by one linear compressor of 200 W electric input. When the two stages are driven by two compressors respectively, with total electric input of 400 W, the prototype has attained a no-load cooling temperature of 12.96 K, which is the lowest temperature ever reported with two-stage Stirling-type pulse tube refrigerators.

  3. He-H2 mixture and Er3NiHx packing for the refrigeration enhancement of pulse tube refrigerator

    Institute of Scientific and Technical Information of China (English)

    CHEN Guobang; TANG Ke; HUANG Yonghua; GAN Zhihua; BAO Rui

    2004-01-01

    The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those with pure He in the temperature region of 30 K. In addition, it is found that Er3Ni, a regenerative material, is able to absorb H2 and produces Er3NiHx. The computation presents that the regenerative performance of Er3NiHx is better than that of Er3Ni due to its higher volume specific heat. Experimental results show that the pulse tube refrigeration performance in 30 K temperature region is enhanced greatly with He-H2mixture and Er3NiHx packing.

  4. Development of a Large-capacity, Stirling-type, Pulse-tube Refrigerator

    Science.gov (United States)

    Potratz, S. A.; Nellis, G. F.; Maddocks, J. R.; Kashani, A.; Helvensteijn, B. P. M.; Rhoads, G. L.; Flake, B.

    2006-04-01

    This paper describes progress towards the development of a large-capacity, single-stage, Stirling-type, pulse-tube refrigerator (PTR) for high temperature superconducting power applications. Specifically, the design and fabrication of an experimental PTR is described followed by a series of design modifications which have focused on optimization of the flow transition components the hot and cold ends of the pulse-tube. Computational fluid dynamic models are described and have been used to guide the design modifications. The impact of each modification on cooler performance is discussed. The cooler is instrumented with piston displacement sensors, high-frequency pressure sensors, and thermocouples along the regenerator wall, within the cold heat exchanger gas volume, and along the pulse-tube wall. These sensors provide some characterization of the flow distribution in the regenerator and pulse-tube.

  5. Development of Recuperator for 4 K Pulse Tube Refrigerators Operating at Opposite Phases

    Science.gov (United States)

    Jung, Jeheon; Jeong, Sangkwon

    2004-06-01

    A 4 K pulse tube refrigerator can be constructed with a recuperator as the second stage regenerator and two pulse tubes operating at opposite phases in the second stage. The recuperator would be the critical component in this configuration, as is the second stage regenerator in typical 4 K cryocoolers. The required condition of this recuperative pulse tube refrigerator for efficient performance is that the recuperator should excel or at least equal the typical second stage regenerator. The recuperator has to have lower pressure drop, lager heat transfer area and smaller void volume. Practically the major difficulty encountered in adapting the recuperator to pulse tube refrigerator is the fact that small void volume is not easily achieved in the recuperator. In order to fulfill such requirement, the recuperator has to be constructed with very narrow channels. The way of constructing narrow channels which is recommended in this paper is forming the metal sheet-porous spacer-metal sheet layers. If the recuperator is constructed in the recommend way in the flat rectangular form, the configuration of placing ports at the four corners with the flow across is revealed to have the optimal performance.

  6. A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling

    Science.gov (United States)

    Miller, Franklin K.

    2012-01-01

    A report describes a pulse tube refrigerator that uses a mixture of He-3 and superfluid He-4 to cool to temperatures below 300 mK, while rejecting heat at temperatures up to 1.7 K. The refrigerator is driven by a novel thermodynamically reversible pump that is capable of pumping the He-3 He-4 mixture without the need for moving parts. The refrigerator consists of a reversible thermal magnetic pump module, two warm heat exchangers, a recuperative heat exchanger, two cold heat exchangers, two pulse tubes, and an orifice. It is two superfluid pulse tubes that run 180 out of phase. All components of this machine except the reversible thermal pump have been demonstrated at least as proof-of-concept physical models in previous superfluid Stirling cycle machines. The pump consists of two canisters packed with pieces of gadolinium gallium garnet (GGG). The canisters are connected by a superleak (a porous piece of VYCOR glass). A superconducting magnetic coil surrounds each of the canisters.

  7. CFD simulation and experimental validation of a GM type double inlet pulse tube refrigerator

    Science.gov (United States)

    Banjare, Y. P.; Sahoo, R. K.; Sarangi, S. K.

    2010-04-01

    Pulse tube refrigerator has the advantages of long life and low vibration over the conventional cryocoolers, such as GM and stirling coolers because of the absence of moving parts in low temperature. This paper performs a three-dimensional computational fluid dynamic (CFD) simulation of a GM type double inlet pulse tube refrigerator (DIPTR) vertically aligned, operating under a variety of thermal boundary conditions. A commercial computational fluid dynamics (CFD) software package, Fluent 6.1 is used to model the oscillating flow inside a pulse tube refrigerator. The simulation represents fully coupled systems operating in steady-periodic mode. The externally imposed boundary conditions are sinusoidal pressure inlet by user defined function at one end of the tube and constant temperature or heat flux boundaries at the external walls of the cold-end heat exchangers. The experimental method to evaluate the optimum parameters of DIPTR is difficult. On the other hand, developing a computer code for CFD analysis is equally complex. The objectives of the present investigations are to ascertain the suitability of CFD based commercial package, Fluent for study of energy and fluid flow in DIPTR and to validate the CFD simulation results with available experimental data. The general results, such as the cool down behaviours of the system, phase relation between mass flow rate and pressure at cold end, the temperature profile along the wall of the cooler and refrigeration load are presented for different boundary conditions of the system. The results confirm that CFD based Fluent simulations are capable of elucidating complex periodic processes in DIPTR. The results also show that there is an excellent agreement between CFD simulation results and experimental results.

  8. Comparison of two models of a Double Inlet Miniature Pulse Tube Refrigerator - Part B Electrical Analogy

    CERN Document Server

    Bailly, Y; Bailly, Yannick; Nika, Philippe

    2002-01-01

    The design of a Double Inlet Pulse Tube Refrigerator is investigated by means of an analogy with an electric circuit. The results obtained with the electric scheme are compared with both those of the thermodynamic model (Part A) and experiments. The basic formulation of equivalent electronic components is discussed and a few improvements are proposed to adjust the theoretical expressions of the electrical impedances of capillaries and regenerator in order to consider additional effects such pressure drops due to geometrical singularities at different internal flow regimes. A simplified formulation for the regenerator inefficiency is deduced from considerations on its harmonic functioning. The main purpose of this analysis considers especially the design of miniature cryocoolers dedicated to electronic applications. These models are applied to a commercial miniature refrigerator. A discussion of their relevance is achieved and a few suggestions on the refrigerator design are proposed to improve the cooling pro...

  9. Comparison of two models of a double inlet miniature pulse tube refrigerator: Part A thermodynamics

    Science.gov (United States)

    Nika, Philippe; Bailly, Yannick

    2002-10-01

    The cooling of electronic components is of great interest to improve their capabilities, especially for CMOS components or infrared sensors. The purpose of this paper is to present the design and the optimization of a miniature double inlet pulse tube refrigerator (DIPTR) dedicated to such applications. Special precautions have to be considered in modeling the global functioning of small scale DIPTR systems and also in estimating the net cooling power. In fact, thermal gradients are greater than those observed in normal scale systems, and moreover, because of the small dimensions of ducts (diameter), the pulse tube cannot be assumed to be adiabatic. Hence thermal heat conduction phenomena must be considered. Besides dead volumes introduced by junctions and capillaries cannot be neglected any more in front of the volume of the gas tube itself. The hydrodynamic and thermal behaviors of the cooler are predicted by means of two different approaches: a classical thermodynamic model and a model based on an electrical analogy. The results of these analysis are tested and criticized by comparing them with experimental data obtained on a small commercial pulse tube refrigerator.

  10. Computational Fluid Dynamic Investigation of Loss Mechanisms in a Pulse-Tube Refrigerator

    Science.gov (United States)

    Martin, K.; Esguerra, J.; Dodson, C.; Razani, A.

    2015-12-01

    In predicting Pulse-Tube Cryocooler (PTC) performance, One-Dimensional (1-D) PTR design and analysis tools such as Gedeon Associates SAGE® typically include models for performance degradation due to thermodynamically irreversible processes. SAGE®, in particular, accounts for convective loss, turbulent conductive loss and numerical diffusion “loss” via correlation functions based on analysis and empirical testing. In this study, we compare CFD and SAGE® estimates of PTR refrigeration performance for four distinct pulse-tube lengths. Performance predictions from PTR CFD models are compared to SAGE® predictions for all four cases. Then, to further demonstrate the benefits of higher-fidelity and multidimensional CFD simulation, the PTR loss mechanisms are characterized in terms of their spatial and temporal locations.

  11. Performance Improvement of Pulse Tube Refrigerator for Space Application with Helium-hydrogen mixture

    Science.gov (United States)

    Chen, G. B.; Yu, J. P.; Gan, Z. H.

    Weight or size of the cryocoolers used is a key factor in space applications This can be acquired by the selection of high efficiency cryocoolers or through the optimization of structural parameters. Given the type of regenerator, another way to improve the cooling performance is the adoption of gas mixture instead of pure helium as the working fluids. Gas mixtures have been proved very useful to J-T cryocoolers at 80K temperature range. In this paper, we do some theoretical and experimental study to probe into the possibility of using gas mixture to improve the coefficient of performance of regenerative cryocoolers such as pulse tube refrigerators. The performance comparison of regenerator using helium-hydrogen mixtures to pure helium gas is presented based on the analysis of the heat transfer and fluid flow. The pressure drop for helium-hydrogen mixture decreased more rapidly than the increase of thermal loss compared with pure helium, so the improvement of overall regenerator performance can be obtained. Experiments have been done with helium-hydrogen mixture in a coaxial valveless pulse tube refrigerator. Experimental results show that the cooling capacity with He-H2 mixture is 10~20 percent larger than that with pure helium, which is in coincidence with the theoretical analysis.

  12. Condensation stage of a pulse tube pre-cooled dilution refrigerator

    Science.gov (United States)

    Uhlig, Kurt

    2008-03-01

    In our article, experiments with a pulse tube (PTR) pre-cooled dilution refrigerator (DR) are presented, where an upgraded 3He condensation stage has been tested. The DR had a 3He flow rate of up to 1.1 mmol/s. The 3He gas entering the refrigerator was first pre-cooled to a temperature of ˜50 K at the first stage of the PTR. In the next cooling step, the 3He was run through a recently installed heat exchanger, which was attached to the regenerator of the second stage of the pulse tube cryocooler; at the outlet of this heat exchanger the temperature of the 3He was as low as ˜4 K. Due to the non-ideality of the helium gas, the second regenerator of a two stage PTR has excess cooling power which can be made use of without affecting the base temperature of this stage, and it is this effect which was put to work, here. Finally, the 3He was further cooled in a heat exchanger, mounted at the second stage of the PTR, before it entered the dilution unit of the cryostat. The installation of a heat exchanger at the regenerator of the second stage of the PTR is especially important for the construction of DRs with high refrigeration capacities; in addition, it allows for a plain design of the subsequent Joule-Thomson (JT) stage, and herewith facilitates considerably the construction of "dry" DRs. The condensation rate of the 3,4He mash prior to an experiment was increased. The pressure during condensation could be kept near 1 bar, and thus a compressor was no longer necessary with the modified apparatus.

  13. Steady Secondary Momentum and Enthalpy Streaming in the Pulse Tube Refrigerator

    Science.gov (United States)

    Lee, J. M.; Kittel, P.; Timmerhaus, K. D.; Radebaugh, R.; Sperans, Joel (Technical Monitor)

    1994-01-01

    Our study investigates the steady secondary streaming that occurs in the pulse tube refrigerator through application of the conservation laws and support by flow visualization experiments. A series expansion of the mass, momentum and energy conservation laws for an axisymmetric system yields a set of linear differential equations. The series solution is expanded in the small parameter epsilon = 1/Str where Str is the Strouhal number. The O(1) basic flow problem is solved for the case of a compressible ideal gas oscillating within a cylindrical tube. The phase and amplitude of the boundary conditions on axial velocity are treated as independent parameters. The basic solution for the gas domain is solved for the case of temperature and heat flux coupling to the tube wall. The temperature coupled solution shows how the Fourier number of the tube wall affects the gas temperature, phase angle, and time-averaged enthalpy flow. The basic solution is also examined for the time-averaged Reynolds stresses which are shown to be the driving force that produces steady secondary momentum streaming. Calculated solutions to the steady momentum streaming are shown to be in qualitative agreement with flow visualization experiments.

  14. Visualization of oscillating flow in a double-inlet pulse tube refrigerator with a diaphragm inserted in a bypass-tube

    Science.gov (United States)

    Shiraishi, Masao; Murakami, Masahide

    2012-07-01

    The double-inlet pulse tube refrigerator that has a diaphragm inserted in a bypass-tube, which enabled it to transmit a pressure oscillation whereas to obstruct a DC gas flow, was manufactured and tested. The oscillating flow behavior inside of the refrigerator was studied by using a smoke-wire flow visualization technique. It was found that if the diaphragm was optimized, the performance would be improved more than that of the refrigerator with a bypass valve due to the increase in the P-V work of the gas and the decrease in the convective heat loss caused by a secondary flow.

  15. Experimental and numerical investigation on performance of a double inlet type cryogenic pulse tube refrigerator

    Science.gov (United States)

    Biswas, Animesh; Ghosh, Subrata K.

    2016-09-01

    A helium filled double inlet pulse tube refrigerator (DIPTR) has been designed, built and operated to provide cryogenic cooling. The experimental studies have been carried out to characterize the performance of the DIPTR at various values of the mean pressure of helium (0.7-1.5 MPa), amplitudes of pressure oscillations, and sizes of orifice opening. A detailed time-dependent three dimensional computational fluid dynamics (CFD) model of the DIPTR has also been developed to predict its performance. In the CFD model, the continuity, momentum and energy equations have been solved for both the refrigerant gas (helium) and the porous media regions (the regenerator and heat exchangers) in the DIPTR. The computational results have been compared with specific experimental results to validate the numerical model. The results predicted by the model show better results as compared to experimental results, as the effects of wall thicknesses and natural convective losses of the various components of the DIPTR to the surroundings have not been included in the model.

  16. Stirling-type pulse tube refrigerator (PTR) with cold compression: Cold compressor, colder expander

    Science.gov (United States)

    Park, Jiho; Ko, Junseok; Cha, Jeongmin; Jeong, Sangkwon

    2016-03-01

    This research paper focuses on the performance prediction and its validation via experimental investigation of a Stirling-type pulse tube refrigerator (PTR) equipped with a cold linear compressor. When the working gas is compressed at cryogenic temperature, the acoustic power (PV power) can be directly transmitted through the regenerator to the pulsating tube without experiencing unnecessary precooling process. The required PV power generated by the linear compressor, furthermore, can be significantly diminished due to the relatively small specific volume of the working gas at low temperature. The PTR can reach lower temperature efficiently with higher heat lift at the corresponding temperature than other typical single-stage Stirling-type PTRs. Utilizing a cryogenic reservoir as a warm end and regulating the entire operating temperature range of the PTR will enable a PTR to operate efficiently under space environment. In this research, the experimental validation as a proof of concept was carried out to demonstrate the capability of PTR operating between 80 K and 40 K. The linear compressor was submerged in a liquid nitrogen bath and the lowest temperature was measured as 38.5 K. The test results were analyzed to identify loss mechanisms with the simple numerical computation (linear model) which considers the dynamic characteristics of the cold linear compressor with thermo-hydraulic governing equations for each of sub components of the PTR. All the mass flows and pressure waves were assumed to be sinusoidal.

  17. Dependence of convective secondary flow on inclination angle in an inclined pulse tube refrigerator revealed by visualization

    Science.gov (United States)

    Shiraishi, Masao; Takamatsu, Koichi; Murakami, Masahide; Nakano, Akihiro

    2004-02-01

    Secondary flow in an inclined orifice pulse tube refrigerator at typical inclination angles of 0-180° was studied by using a smoke-wire flow visualization technique. It was revealed that the secondary flow formed a unicellular convective flow in the pulse tube and had two flow patterns depending on the angle. This dependence of flow pattern on the inclination angle is well explained by the superposition of gravity-driven convective flow on acoustic streaming. Even if the cold end was lower than the hot end, the gravity-driven convective flow occurred and the secondary flow was affected by gravity.

  18. Experimental Investigation on Regenerator Materials of Stirling-type Pulse-tube Refrigerator Working at 20 K

    Science.gov (United States)

    Zhou, Qiang; Chen, Liubiao; Pan, Changzhao; Zhou, Yuan; Wang, Junjie

    This paper will introduce our recent experimental results of cryogenic regenerator materials employed in Stirling-type one-stage pulse-tube refrigerator for the use at liquid hydrogen temperature. Thermal diffusion coefficient, according to which we choose the suitable regenerator materials, will prove to be a useful reference. We will also discuss the impact of resistance of sphere regenerator materials on the performance of the refrigerator and the method to improve it. Take an overall consideration, suitable-size Er3Ni will be applied as the regenerator materials at the cold head and we achieve a remarkable 14.7 K no-load temperature.

  19. Improvement of xenon purification system using a combination of a pulse tube refrigerator and a coaxial heat exchanger

    CERN Document Server

    Chen, Wan-Ting; Cussonneau, J -P; Donnard, J; Duval, S; Lemaire, O; Calloch, M Le; Ray, P Le; Mohamad-Hadi, A -F; Morteau, E; Oger, T; Scotto-Lavina, L; Stutzmann, J -S; Thers, D; Briend, P; Haruyama, T; Mihara, S; Tauchi, T

    2012-01-01

    We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in a highpressurized large-scale xenon storage with much less thermal losses.

  20. Numerical simulation of a three-stage stirling-type pulse-tube refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Etaati, M.A.

    2011-06-22

    The pulse-tube refrigerator (PTR) is a rather new device for cooling down to extremely low temperatures, i.e. below 4 K. The PTR works by the cyclic compression and expansion of helium that flows through a regenerator made of porous material, a cold heat exchanger, a tube, a hot heat exchanger and an orifice, in series. In a Stirling-type PTR compression and expansion are generated by a piston. The compression increases the temperature of the helium in the tube and makes it flow towards the orifice; the expansion decreases the temperature and makes the helium flow backwards to the regenerator. The net effect of warmer helium flowing in one direction and colder helium in the opposite direction is that of cooling power at the cold heat exchanger. Three PTRs are inter-connected aiming to obtain the desired 4 K lowest temperature. The conservation laws of mass, momentum and energy, and an equation of state, are simplified using asymptotic analysis based on low Mach-numbers. The regenerator is modelled one-dimensionally with Darcy's law for flow resistance. The tube is modelled either one-dimensionally without resistance or two-dimensionally with axisymmetric laminar viscous flow. The heat transfer in the porous medium of the regenerator and in the solid tube wall is taken into account. The gas can be either ideal or real. All the material properties, including viscosity and conductivity, are taken temperature and pressure dependent. Three single-stage PTRs are connected with the regenerators in series and the tubes in parallel and six flow possibilities at the junctions are considered. Three by-passes (double-inlets) are used to enhance and tune the performance. The governing equations are numerically solved with a finite-difference method of nominally second-order accuracy in space and time. Pressure correction, flux limiter, 1D-2D connections and domain decomposition are the keywords here. Special attention is paid to suitable initial conditions, high resolution

  1. Thermodynamic Analysis and Optimization Based on Exergy Flow for a Two-Staged Pulse Tube Refrigerator

    Science.gov (United States)

    2010-01-01

    and magnetostriction Rev. Sci. Instrum. 83, 095102 (2012) Compact radio-frequency resonator for cryogenic ion traps Rev. Sci. Instrum. 83, 084705...Vol. 55, edited by J. G. Weisend II 2010 American Institute of Physics 978-0-7354-0761-9/10/$30.00 INTRODUCTION Multi-stage Pulse Tube

  2. Visualization study on effects of frequency on acoustic streaming in a pulse tube refrigerator; Parusu kan reitokinai ni yukisareru nijitekina nagare ni oyobosu shuhasu no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, M.; Nakano, A. [Mechanical Engineering Laboratory, Tsukuba (Japan); Takamatsu, K.; Murakami, M. [Univ. of Tsukuba, Tsukuba (Japan)

    1999-11-10

    It induces the otherwise secondary and fundamental flow in pulse tube refrigerating machine of an oscillating flow. This secondary flow is connected with the improvement on the performance, if it can be reduced, since it becomes a cause of the usual heat loss. Therefore, we systematically examine the secondary flow induced in the pulse tube refrigerator. Until now, the dependent main factor by sound flow secondary flow and existence of a natural convection secondary flow and angle value of the refrigeration performance clarified the fact by the generation of a natural convection secondary flow. Here, it introduces the result of examining frequency dependence and effect of compression ratio in the visualization experiment on characteristics of a sound flow secondary flow, which always exists. (NEDO)

  3. Study on LXe system for particle detector. Liquefaction test by pulse tube refrigerator; Ryushi kenshutsuyo ekitai Xenon shisutemu no kenkyu. Parusu kan reitokini yoru ekika

    Energy Technology Data Exchange (ETDEWEB)

    Haruyama, T.; Kasami, K. [High energy Accelerator Research Organization, Tsukuba (Japan)

    1999-11-10

    It is supersensitively used for the particle detection from electrons and that they release the light, that it can deal with fast process, etc. for the high-energy particle which emits liquid Xenon. It recently proposes the experiment which uses large liquid Xenon as a calorimeter in order to detect {gamma}ray of the high energy. It examines the thermal characteristic of liquid Xenon, while this study attempts the optimization in liquefying Xenon by pulse tube refrigerating machine. This time, the following are reported: Introduction of the Xenon gas system for the small-scale liquefaction experiment and experiment near 165K of small pulse tube refrigerating machine on a refrigerating capacity. (NEDO)

  4. Two-stage high frequency pulse tube cooler for refrigeration at 25 K

    CERN Document Server

    Dietrich, M

    2009-01-01

    A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first stage, since the intended application requires no cooling power at an intermediate temperature. Simulations where done using Sage-software to find optimum operating conditions and cold head geometry. Flow-impedance matching was required to connect the compressor designed for 60 Hz operation to the 40 Hz cold head. A cooling power of 12.9 W at 25 K with an electrical input power of 4.6 kW has been achieved up to now. The lowest temperature reached is 13.7 K.

  5. Experimental study of thermo-fluiddynamic phenomena in a regenerator of pulse tube refrigerator; Parusu kan reitoki no chikureikinai no netsuryutai gensho

    Energy Technology Data Exchange (ETDEWEB)

    Takamatsu, K.; Murakami, M. [Univ. of Tsukuba, Tsukuba (Japan); Shiraishi, M.; Nakano, A. [Mechanical Engineering Laboratory, Tsukuba (Japan)

    1999-11-10

    The regeneration vessel occupies the important part in the design of the real machine of pulse tube refrigerating machine. However, it is not supposed that thermo-fluiddynamic phenomena of the regeneration vessel inside under operation of the real machine have sufficiently been grasped. We advance the investigation on thermo-fluiddynamic phenomena under the operating condition in the regeneration vessel. Here, it introduces the part of the result got until now. (NEDO)

  6. Useful Scaling Parameters for the Pulse Tube

    Science.gov (United States)

    Lee, J. M.; Kittel, P.; Timmerhaus, K. D.; Radebaugh, R.; Cheng, Pearl L. (Technical Monitor)

    1995-01-01

    A set of eight non-dimensional scaling parameters for use in evaluating the performance of Pulse Tube Refrigerators is presented. The parameters result after scaling the mass, momentum and energy conservation equations for an axisymmetric, two-dimensional system. The physical interpretation of the parameters are described, and their usefulness is outlined for the enthalpy flow tube (open tube of the pulse tube). The scaling parameters allow the experimentalist to characterize three types of transport: enthalpy flow, mass streaming and heat transfer between the gas and the tube. Also reported are the results from a flow visualization experiment in which steady mass streaming in compressible oscillating flow is observed.

  7. Condensation of refrigerants on vertical fluted tubes

    Energy Technology Data Exchange (ETDEWEB)

    Combs, S.K.; Mailen, G.S.; Murphy, R.W.

    1978-08-01

    Experiments were run to determine heat transfer performance of single vertical fluted tubes with selected fluids condensing on the outside. Working fluids included six fluorocarbons (Refrigerants 11, 21, 22, 113, 114, and 115) and a hydrocarbon (Refrigerant 600a or isobutane). The nine test tubes were of 2.54-cm (1-in.) nominal outside diameter and 1.2 m (4 ft) in length with from 0 (smooth) to 60 axial flutes. Condensing heat transfer coefficients ranged from 620 to 7900 W/m/sup 2/ . K (110 to 1400 Btu/hr . ft/sup 2/ . /sup 0/F) over the heat flux range of 2000 to 43,000 W/m/sup 2/ (920 to 13,600 Btu/hr . ft/sup 2/). All parameters are based on total condensing surface area. The data show that, for a given heat flux, a fluted tube can increase condensing coefficients up to 6.0 times smooth tube values. Further heat transfer enhancement was achieved by the use of drainage skirts on fluted tubes; these skirts effectively divided the 1.2-m (4-ft) tubes into two, four, and eight equal condensing lengths.

  8. Performance of a tapered pulse tube

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.; Allen, M.; Woolan, J.J. [Cryenco Inc., Denver, CO (United States)

    1998-02-01

    In a well instrumented pulse tube refrigerator having 1,500 W of cooling power at 125 K, the authors have measured the figure of merit of a tapered pulse tube at several operating points. At operating points near the operating point for which the taper was designed, the figure of merit is 0.96. This is close to the theoretical optimum figure of merit 0.97 calculated for this pulse tube considering only two loss mechanisms: heat conduction in the metal pulse tube wall and ordinary thermoacoustic heat transport in the gas within a few thermal penetration depths of the wall. At operating points farther from the design operating point, the measured figure of merit is much lower, as streaming driven convection adds a third loss mechanism.

  9. Performance of a tapered pulse tube

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.; Allen, M.; Woolan, J.J. [Cryenco Inc., Denver, CO (United States)

    1998-02-01

    In a well instrumented pulse tube refrigerator having 1,500 W of cooling power at 125 K, the authors have measured the figure of merit of a tapered pulse tube at several operating points. At operating points near the operating point for which the taper was designed, the figure of merit is 0.96. This is close to the theoretical optimum figure of merit 0.97 calculated for this pulse tube considering only two loss mechanisms: heat conduction in the metal pulse tube wall and ordinary thermoacoustic heat transport in the gas within a few thermal penetration depths of the wall. At operating points farther from the design operating point, the measured figure of merit is much lower, as streaming driven convection adds a third loss mechanism.

  10. 基于热力学非对称效应的脉冲管制冷机模拟方法的改进%MODIFIED SIMULATION OF PULSE TUBE REFRIGERATOR BASED ON THERMODYNAMIC NON-SYMMETRY EFFECT

    Institute of Scientific and Technical Information of China (English)

    戴巍; 王如竹; 周远

    2000-01-01

    In this article, the theory of thermodynamic non-symmetry effect and some problems in using this theory by former researchers are discussed. Then we give a modified simulation procedure to improve calculation accuracy. Understanding of mechanism inside pulse tube refrigerator is thus further deepened. Some results are given for comparison, which shows that accuracy of refrigeration power and mass flow rate calculation may improve by over 20%.%本文讨论了热力学非对称理论以及目前应用它的过程中存在的问题,在此基础之上编制了改进的程序,可以更深入地理解脉冲管的内部过程.从给出的一些计算结果来看,计算的精度可能会提高20%以上.

  11. Available energy analysis of new tandem double-capillary tube refrigeration system for refrigerator-freezers

    Institute of Scientific and Technical Information of China (English)

    Maogang HE; Xinzhou SONG; Ying ZHANG; Jiantao ZHANG

    2008-01-01

    A new tandem double-capillary tube refri-geration system for refrigerator-freezers is proposed. A capillary tube was added between the two evaporators in the fresh and frozen food storage chests to raise the evaporation temperature of the refrigerating chamber, and reduce the heat exchange temperature difference and the available energy loss. Peng-Robinson (P-R) equation of state was adopted to calculate the thermodynamic properties of the refrigerants, and the available energy analysis of the vapor compression refrigeration cycle was programmed to calculate the thermodynamic perfor-mances of the new and the conventional refrigeration cycle of the refrigerator-freezer. The calculation results show that the available energy efficiency of the conven-tional refrigeration cycle of the refrigerator-freezer is 21.20% and 20.57%, respectively when the refrigerant is R12 and R134a, while that of the double-capillary tube refrigeration cycle of the refrigerator-freezer is 23.97% and 23.44%, respectively. By comparison, the available energy efficiency of the new refrigeration system increases by 13.07% and 13.95%, respectively.

  12. The pulsed-gas tube, statement and perspectives; Le tube a gaz pulse, bilan et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Domblides, J.P.; Neveau, P.; Castaing-Lasvignottes, J. [Laboratoire du froid du CNAM, 75 - Paris (France)

    1997-12-31

    The pulsed-gas tube has several advantages with respect to the other types of cryo-refrigerating machineries classically used to reach very low temperatures: no mobile parts moving at very low temperatures and no vibrations. However, this system discovered in 1963 is handicapped by its lack of power and by its low energy efficiency. Todays researches about pulsed-gas tubes concern: the technical adaptation of existing systems to applications where its simplicity makes it competitive, the improvement of its energetic performances (refrigerating power and range of temperatures of use), and the development of numerical models in order to better understand the functioning of the system and to optimize it. (J.S.) 19 refs.

  13. Improved Refrigerant Characteristics Flow Predictions in Adiabatic Capillary Tube

    Directory of Open Access Journals (Sweden)

    Shodiya Sulaimon

    2012-07-01

    Full Text Available This study presents improved refrigerant characteristics flow predictions using homogenous flow model in adiabatic capillary tube, used in small vapor compression refrigeration system. The model is based on fundamental equations of mass, momentum and energy. In order to improve the flow predictions, the inception of vaporization in the capillary tube is determined by evaluating initial vapor quality using enthalpy equation of refrigerant at saturation point and the inlet entrance effect of the capillary tube is also accounted for. Comparing this model with experimental data from open literature showed a reasonable agreement. Further comparison of this new model with earlier model of Bansal showed that the present model could be use to improve the performance predictions of refrigerant flow in adiabatic capillary tube.

  14. Why high-frequency pulse tubes can be tipped

    Energy Technology Data Exchange (ETDEWEB)

    Swift, Gregory W092710 [Los Alamos National Laboratory; Backhaus, Scott N [Los Alamos National Laboratory

    2010-01-01

    The typical low-frequency pulse-tube refrigerator loses significant cooling power when it is tipped with the pulse tube's cold end above its hot end, because natural convection in the pulse tube loads the cold heat exchanger. Yet most high-frequency pulse-tube refrigerators work well in any orientation with respect to gravity. In such a refrigerator, natural convection is suppressed by sufficiently fast velocity oscil1ations, via a nonlinear hydrodynamic effect that tends to align the density gradients in the pulse tube parallel to the oscillation direction. Since gravity's tendency to cause convection is only linear in the pulse tube's end-to-end temperature difference while the oscillation's tendency to align density gradients with oscillating velocity is nonlinear, it is easiest to suppress convection when the end-to-end temperature difference is largest. Simple experiments demonstrate this temperature dependence, the strong dependence on the oscillating velocity, and little dependence on the magnitude or phase of the oscillating pressure. In some circumstances in this apparatus, the suppression of convection is a hysteretic function of oscillating velocity. In some other circumstances, a time-dependent convective state seems more difficult to suppress.

  15. Condensation of refrigerants flowing inside smooth and corrugated tubes

    Energy Technology Data Exchange (ETDEWEB)

    Hinton, D.L. [Tennessee State Univ., Nashville, TN (United States); Conklin, J.C.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States)

    1995-07-01

    Because heat exchanger thermal performance has a direct fluence on the overall cycle performance of vapor-compression refrigeration machinery,enhanced heat transfer surfaces are of interest to improve the efficiency of heat pumps and air conditioners. We investigated R-22 and a nonazeotropic refrigerant mixture (NARM) of 75% R-143a and 25% R-124 (by mass) to study their thermal performance in a condenser made of conventional smooth tubes and another condenser made of corrugated, or spirally indented, tubes. We investigated the condensing heat transfer and pressure drop characteristics in an experimental test loop model of a domestic beat pump system employing a variable speed compressor. The refrigerant circulates inside the central tube and the water circulates in the annulus. At refrigerant mass fluxes of approximately 275--300 kg/m{sup 2}s, the measured irreversible pressure drop of the corrugated surface was 23% higher than that of the smooth surface for the R-22. At refrigerant mass fluxes of 350-370 kg/m{sup 2}s, the irreversible pressure drop of the corrugated surface was 36% higher than that of the smooth surface for the NARM. The average heat transfer coefficient for the corrugated surface for R-22 was roughly 40% higher than that for the smooth tube surface at refrigerant mass fluxes of 275--295 kg/m{sup 2}s. The average heat transfer coefficient for the corrugated surface for the NARM was typically 70% higher than that for the smooth tube surface at refrigerant mass fluxes of 340--385 kg/m{sup 2}s.

  16. Useful scaling parameters for the pulse tube

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.M.; Kittel, P. [NASA Ames Research Center, Moffett Field, CA (United States); Timmerhaus, K.D. [Univ. of Colorado, Boulder, CO (United States)] [and others

    1996-12-31

    A set of dimensionless scaling parameters for use in correlating performance data for Pulse Tube Refrigerators is presented. The dimensionless groups result after scaling the mass and energy conservation equations, and the equation of motion for an axisymmetric, two-dimensional ideal gas system. Allowed are viscous effects and conduction heat transfer between the gas and the tube wall. The scaling procedure results in reducing the original 23 dimensional variables to a set of 11 dimensionless scaling groups. Dimensional analysis is used to verify that the 11 dimensionless groups obtained is the minimum number needed to describe the system. The authors also examine 6 limiting cases which progressively reduce the number of dimensionless groups from 11 to 3. The physical interpretation of the parameters are described, and their usefulness is outlined for understanding how heat transfer and mass streaming affect ideal enthalpy flow.

  17. Theoretical Design of adiabatic capillary tube of a domestic refrigerator using refrigerant R-600a.

    Directory of Open Access Journals (Sweden)

    Sahoo. K. C

    2016-08-01

    Full Text Available This paper develops a more accurate theoretical procedure for the design of adiabatic capillary tube of a domestic refrigerator considering a rigorous pressure drop analysis on the refrigerant R-600a while expanding through that tube accompanied with phase change through flash vaporization. Here this eliminates the contradiction of existing concepts on the negative value of the frictional pressure drop after a short distance of expansion due to a large part contribution of the actual pressure drop towards the momentum gain pressure drop. Also this verifies that the momentum gain through phase change is by consumption of internal energy part of the enthalpy and no part of the actual pressure drop energy is used in this respect. So with the concept of nearly total pressure drop being used in overcoming the friction the design of an adiabatic capillary tube of available I mm diameter for 0.1 ton refrigeration capacity has been carried out here. This design procedure causes some increase in the required length of the capillary for a given refrigeration capacity due to the omission of momentum pressure drop concept of different references, but is more accurate with consideration of actual changes involved in the expansion. The procedure is applicable for any other refrigerant of any refrigeration capacity

  18. Transient response of finned-tube condenser in household refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Porkhial, S. [Technical Department, Karaj Branch, Islamic Azad University, Tehran (Iran); Khastoo, B. [Mechanical Engineering Department, Amirkabir University, Tehran (Iran); Modarres Razavi, M.R. [Mechanical Engineering Department, Ferdowsi University, Mashhad (Iran)

    2006-10-15

    A distributed parameter model for prediction of the transient performance of a condenser is presented. The model is capable of predicting the refrigerant temperature distribution, tube wall temperature, quality of refrigerant, inventory mass of refrigerant as a function of position and time. An efficient two-level iteration method is proposed to obtain the numerical solution of the model without solving a large set of non-linear equations simultaneously. A finned tube condenser of 12ft{sup 3} refrigerator with R12 as working fluid was chosen as a sample and some tests were carried out to determine its transient response. The examination of results indicates that the theoretical model provides a reasonable prediction of dynamic response compared to the experimental data. Transient behavior of temperature, pressure, mass flow rate, mass of liquid and vapor of refrigerant, quality, heat transfer in household refrigerators have been presented. Also time-dependent displacement of interface between saturated and superheated regions has been shown. Extensive examinations of theoretical and experimental results show that with utilization of a controllable compressor, power consumption can be reduced. (author)

  19. Enhancenment of In-tube Condensation of Nonazeotropic Refrigerant Mixtures with a Micro-fin Tube

    Science.gov (United States)

    Koyama, Shigeru; Gao, Lei; Hujii, Tetsu

    Condensation heat transfer and pressure drop characteristics of nonazeotropic refrigerant mixtures (NARMs) of HCFC22 and CFC114 inside horizontal smooth and micro-fin tubes are experimentally investigated. The local Nusselt number for both tubes based on the temperature difference between bulk refrigerant and tube wall is compared. Data for the micro-fin tube are about 50% higher than those for the smooth tube in both cases of pure refrigerants and NARMs. In case of NARMs, however, the decrease of Nesselt number due to vapor mass transfer resistance is observed for the micro-fin tube as well as for the smooth tube. By assuming that heat transfer characteristics of the condensate of NARMs are similar to those for pure refrigerants, the vapor mass transfer coefficient of NARMs is evaluated. Comparison of frictional pressure drop for both tubes is also performed in the Lockharte-Martinelli relation. Data for the micro-fin tube are higer than those for the smooth tube. The maximum increase of the frictional pressure drop is about 30%.

  20. Development of a 4K pulse tube cryocooler for space use (2); Uchuyo 4K parusu chubu reitoki no kaihatsu (2)

    Energy Technology Data Exchange (ETDEWEB)

    Iida, T. [Natinal Space development Agency of Japan, Tokyo (Japan); Naraita, M.; Murakami, H. [The Inst. of Space and Astronautical Science, Tokyo (Japan); Matsubara, Y. [Nihon Univ., Tokyo (Japan); Otani, Y.; Kuriyama, T. [Toshiba Corp., Tokyo (Japan); Kasamatsu, S.; Okamura, T.; Kabashima, S. [Tokyo Inst. of Tech., Tokyo (Japan)

    1999-11-10

    In this study, it measured refrigeration performance of the precooling style pulse tube refrigerator reported in 'Development of a 4K pulse tube cryocooler for space use (1)'. This paper must consider input electric power which is necessary for the precooling of second stage and first in addition to the isothermal compression work of pulse tube refrigerator, when a fixed refrigerating capacity is obtained at 4.2K, in order to do the optimization of the whole system including refrigerating machine for the precooling. Especially, it was proven that the latter reduction greatly influenced the efficiency of the whole system. (NEDO)

  1. 10 K high frequency pulse tube cryocooler with precooling

    Science.gov (United States)

    Liu, Sixue; Chen, Liubiao; Wu, Xianlin; Zhou, Yuan; Wang, Junjie

    2016-07-01

    A high frequency pulse tube cryocooler with precooling (HPTCP) has been developed and tested to meet the requirement of weak magnetic signals measurement, and the performance characteristics are presented in this article. The HPTCP is a two-stage pulse tube cryocooler with the precooling-stage replaced by liquid nitrogen. Two regenerators completely filled with stainless steel (SS) meshes are used in the cooler. Together with cold inertance tubes and cold gas reservoir, a cold double-inlet configuration is used to control the phase relationship of the HPTCP. The experimental result shows that the cold double-inlet configuration has improved the performance of the cooler obviously. The effects of operation parameters on the performance of the cooler are also studied. With a precooling temperature of 78.5 K, the maximum refrigeration capacity is 0.26 W at 15 K and 0.92 W at 20 K when the input electric power are 174 W and 248 W respectively, and the minimum no-load temperature obtained is 10.3 K, which is a new record on refrigeration temperature for high frequency pulse tube cryocooler reported with SS completely used as regenerative matrix.

  2. Visualization of gas displacement and temperature distribution in the pulse tube; Parusukan nai deno ryutai no kyodo kashika

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.

    1999-11-10

    It is important that measures and visualizes displacement and temperature distribution of the fluid to which vibrate in pulse service area of pulse tube refrigerating machine in order to attempt understanding and performance improvement of the refrigeration principle. Then, example of light measurement method of the fluid displacement using the sphere which the transfer possibly installed in pulse service area and measurement method of temperature distribution using the plane laser Rayleigh scattering method and each measuring result is outlined in this lecture. (NEDO)

  3. Development of a 4K pulse tube cryocooler for space use (1); Uchuyo 4K parusu chubu reitoki no kaihatsu (1)

    Energy Technology Data Exchange (ETDEWEB)

    Iida, T. [Natinal Space development Agency of Japan, Tokyo (Japan); Naraita, M.; Murakami, H. [The Inst. of Space and Astronautical Science, Tokyo (Japan); Matsubara, Y. [Nihon Univ., Tokyo (Japan); Otani, Y.; Kuriyama, T. [Toshiba Corp., Tokyo (Japan); Kasamatsu, S.; Okamura, T.; Kabashima, S. [Tokyo Inst. of Tech., Tokyo (Japan)

    1999-11-10

    Slide and moving part are not in the low-temperature division, and pulse tube refrigerator, which develops the small refrigerating machine with the aim of for space, is excellent concerning the reliability. In the cooling of the 80K level, it carries out the development of pulse tube refrigerator with the efficiency in which the Stirling refrigerating machine level is high. In the 4K level, the development of two-step pulse tube refrigerator with performance of the GM refrigerating machine level of the 1W class also advances. We precool it by the refrigerating machine, which is different to the 20K level, and it develops precooling style 4K pulse tube refrigerator that carries out the cooling under it by pulse tube refrigerator. We carried out parameter radiation survey for making a goal refrigerating capacity to be 25mW, and for measuring the heat flow of compression work and precooling division of the compressor, and for searching the optimum operating condition. (NEDO)

  4. Investigation of pressure drop in capillary tube for mixed refrigerant Joule-Thomson cryocooler

    Energy Technology Data Exchange (ETDEWEB)

    Ardhapurkar, P. M. [Mechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, MS 400 076 India and S. S. G. M. College of Engineering Shegaon, MS 444 203 (India); Sridharan, Arunkumar; Atrey, M. D. [Mechanical Engineering Department, Indian Institute of Technology Bombay, Mumbai, MS 400 076 (India)

    2014-01-29

    A capillary tube is commonly used in small capacity refrigeration and air-conditioning systems. It is also a preferred expansion device in mixed refrigerant Joule-Thomson (MR J-T) cryocoolers, since it is inexpensive and simple in configuration. However, the flow inside a capillary tube is complex, since flashing process that occurs in case of refrigeration and air-conditioning systems is metastable. A mixture of refrigerants such as nitrogen, methane, ethane, propane and iso-butane expands below its inversion temperature in the capillary tube of MR J-T cryocooler and reaches cryogenic temperature. The mass flow rate of refrigerant mixture circulating through capillary tube depends on the pressure difference across it. There are many empirical correlations which predict pressure drop across the capillary tube. However, they have not been tested for refrigerant mixtures and for operating conditions of the cryocooler. The present paper assesses the existing empirical correlations for predicting overall pressure drop across the capillary tube for the MR J-T cryocooler. The empirical correlations refer to homogeneous as well as separated flow models. Experiments are carried out to measure the overall pressure drop across the capillary tube for the cooler. Three different compositions of refrigerant mixture are used to study the pressure drop variations. The predicted overall pressure drop across the capillary tube is compared with the experimentally obtained value. The predictions obtained using homogeneous model show better match with the experimental results compared to separated flow models.

  5. Transient analysis of single stage GM type double inlet pulse tube cryocooler

    Science.gov (United States)

    Gujarati, P. B.; Desai, K. P.; Naik, H. B.; Atrey, M. D.

    2015-12-01

    Transient analysis of single stage GM type double inlet pulse tube cryocooler is carried out using a one dimensional numerical model based on real gas properties of helium. The model solves continuity, momentum and energy equation for gas and solid to analyse the physical process occurring inside of the pulse tube cryocooler. Finite volume method is applied to discretize the governing equations with realistic initial and boundary conditions. Input data required for solving the model are the design data and operating parameters viz. pressure waveform from the compressor, regenerator matrix data, and system geometry including pulse tube, regenerator size and operating frequency for pulse tube cryocooler. The model investigates the effect of orifice opening, double inlet opening, pressure ratio, system geometry on no load temperature and refrigeration power at various temperatures for different charging pressure. The results are compared with experimental data and reasonable agreement is observed. The model can further be extended for designing two stage pulse tube cryocooler.

  6. Evaporation of refrigerant HFC 407C on plain tubes or at an improved surface; Evaporation du refrigerant HFC 407C sur des tubes lisses ou a surface amelioree

    Energy Technology Data Exchange (ETDEWEB)

    Zuercher, O.; Favrat, D.; Thome, J.R.; Kattan, N.; Nidegger, E. [Ecole polytechnique federale, Lab. d`energetique industrielle, Lausanne (Switzerland)

    1996-11-15

    The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, requires good methods for predicting heat transfer of substitute fluids. The measurements in the LENI test facility (concentric tubes with water flowing in a counter-current flow) with HFC 407C, HFC 134a, HCFC 123, HFC 404a and HFC/HCFC 402A provide a new data bank for new refrigerants, and allow a coherent comparison with old refrigerants CFC 11, CFC 12, CFC/HCFC 502 and with existing correlations. The existing correlations were found to be inadequate. Because of this work, an improved flow pattern map and flow boiling model were developed, which resulted in a substantial progress in the accurate predict of heat transfer in plain, horizontal tubes for refrigerants without oil. The Kattan et al. correlation was programmed to calculate and compare predicted heat transfer coefficients to the new HFC 407C test data. The flow pattern map proposed by Kattan et al. was also programmed and compared to flow regimes observed for HFC 407C. It predicted the HFC 407C flow pattern data quite accurately. The original objective of the HFC 407C measurements was the validation of the Kattan et al. correlation applied to a zeotropic refrigerant blend. Local flow boiling heat transfer coefficients were measured for HFC 407C evaporating inside a microfin and a plain tube. In addition, microfin heat transfer augmentation relative to a plain tube was investigated. The presence of oil in the evaporator had a complex effect on heat transfer coefficients. Local flow boiling heat transfer coefficients were measured for refrigerant HFC 407C ester oil mixtures (Mobil EAL Arctic 68). A new thermodynamic approach for modeling mixtures of zeotropic refrigerant blends and lubricating oils was also developed. (author) figs., tabs., 14 refs.

  7. Ultimate Temperature of Pulse Tube Cryocoolers

    Science.gov (United States)

    Kittel, P.

    2010-04-01

    An ideal pulse tube cryocooler using an ideal gas can operate at any temperature. This is not true for real gasses. The enthalpy flow resulting from the real gas effects of 3He, 4He, and their mixtures in ideal pulse tube cryocoolers puts limits on the operating temperature of pulse tube cryocoolers. The discussion of these effects follows a previous description of the real gas effects in ideal pulse tube cryocoolers and makes use of models of the thermophysical properties of 3He and 4He. Published data is used to extend the analysis to mixtures of 3He and 4He. The analysis was done for pressures below 2 MPa and temperatures below 2.5 K. Both gasses and their mixtures show low temperature limits for pulse tube cryocoolers. These limits are in the 0.5-2.2 K range and depend on pressure and mixture. In some circumstances, even lower temperatures may be possible. Pulse tube cryocoolers using the two-fluid properties of dilute 3He in superfluid 4He appear to have no limit.

  8. Experimental Study on Condensation of Pure Refrigerants in Horizontal Micro-fin Tubes

    Science.gov (United States)

    Yonemoto, Ryuichiro; Koyama, Shigeru

    This paper presents the heat transfer and pressure drop correlations for condensation in micro-fin tubes. Experimental data for eleven micro-fin tubes with different fin dimensions were used, and the refrigerants tested were R22, R123 and R134a. The predicted results using new correlations show good agreement with experimental results within an absolute deviation of ±30%. Experimental results for the micro-fin tubes were also compared with previous correlations for micro-fin Tubes.

  9. Boiling heat transfer correlations for refrigerant mixtures flowing inside micro-fin tubes

    Institute of Scientific and Technical Information of China (English)

    Xiaoyan ZHANG; Xingqun ZHANG; Yunguang CHEN; Xiuling YUAN

    2008-01-01

    Based on experimental results of ternary non-azeotropic refrigerant mixture R417A flowing and boiling in one smooth and two internally grooved horizontal tubes with different geometrical parameters, a boiling heat transfer correlations was developed for refrigerant mix-tures flowing inside micro-fin tubes by applying the enhancement factor in the present modified-Kattan model which was modified by the experimental data of R417A in a smooth tube. The comparison between the calculation and the experimental results indicates that the prediction by the present correlations is in good agreement with the experiment of refrigerant mixtures inside different micro-fin tubes with a standard deviation of ± 30% for vapor qualities below 80%.

  10. Condensation and evaporation of new refrigerants in advanced micro-finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Laterrible, P. [Trefimetaux, 92 - Courbevoie (France); Marvillet, C. [CEA/Grenoble, Dept. de Thermohydraulique et de Physique (DTP-GRETH), 38 (France)

    1999-07-01

    Due to the European deadline for the phase-out of HCFCs, the air-conditioning manufacturers are launching new product range purpose-designed to operate on the non-ozone depleting refrigerants: R404A, R134a or R407C. The micro-finned tubes optimised for finned heat exchangers as for shell and tube evaporators and condensers are one of these recent techniques which may allow increase performance of refrigerating units the new refrigerants. Two models of thermal correlation have been established resulting from experimental measurements on single micro-fin tubes: in evaporation, the model is a modification of Gungor-Winterton which concerns the addition of nucleation and convection processes within the inner grooves. In condensation, this model is a modification of Cavallini-Zecchin correlation. With these models, it is possible to predict the behaviour micro-fin tubes in specific conditions. This permits the necessary adaptation of heat-exchangers. (authors)

  11. Condensation of Refrigerant-11 on the outside of horizontal and inclined enhanced tubes

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, N.

    1982-12-01

    Heat transfer condensation tests with Refrigerant-11 were performed on the outside of a smooth tube and a variety of enhanced tubes oriented horizontally and at various tube inclinations. One smooth tube and seven enhanced (externally fluted, roped, spiraled, and externally finned) tubes of 2.54-cm (1-in.) nominal outside diameter and 1.17-m (4-ft) length were tested. Several of the tested tubes featured internal enhanced geometries, which were caused by the heat transfer enhancing geometry on the tube's external surface. Condensing heat transfer coefficients are reported as composite coefficients, which combine the resistance of the condensing film and the tube wall, and are based on total tube outside surface area. Results show that in the horizontal condensing mode, the rank order (best to worst) of the tube geometries tested was spiral-shaped tubes, rope-shaped tubes, smooth tube, externally finned tube, and externally fluted tube. For a spiral-shaped tube, horizontal composite coefficients were up to 2.0 times the corresponding horizontal smooth tube values. For tilt angles greater than or equal to 60/sup 0/ from the horizontal, the condensing performance of the externally fluted tube was best of all the tubes tested.

  12. A three-stage Stirling pulse tube cryocooler operating below the critical point of helium-4

    Science.gov (United States)

    Qiu, L. M.; Cao, Q.; Zhi, X. Q.; Gan, Z. H.; Yu, Y. B.; Liu, Y.

    2011-10-01

    Precooled phase shifters can significantly enhance the phase shift effect and further improve the performance of pulse tube cryocoolers. A separate three-stage Stirling pulse tube cryocooler (SPTC) with a cold inertance tube was designed and fabricated. Helium-4 instead of the rare helium-3 was used as the working fluid. The cryocooler reached a bottom temperature of 4.97 K with a net cooling power of 25 mW at 6.0 K. The operating frequency was 29.9 Hz and the charging pressure was 0.91 MPa. It is the first time a refrigeration temperature below the critical point of helium-4 was obtained in a three-stage Stirling pulse tube cryocooler.

  13. Effect of refrigerant mal-distribution in fin-and-tube evaporators on system performance

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Elmegaard, Brian; Larsen, Lars Finn Sloth

    2009-01-01

    the condenser is a dynamic moving boundary model. The evaporator model is a dynamic distributed one-dimensional homogeneous equilibrium model, in order to capture the distribution phenomena. Fin-and-tube heat exchangers usually have a complex circuitry, however the evaporator will be simplified to be two...... straight tubes. The refrigerant mal-distribution is then induced to the evaporator by varying the vapor quality at the inlet to each feeder tube, the pressure drop through each feeder tube and the air-flow across each tube. Finally it is shown that air-flow mal-distribution can be compensated...

  14. Performance investigation of capillary tubes for machine tool coolers retrofitted with HFC-407C refrigerant

    Science.gov (United States)

    Wang, Fujen; Chang, Tongbou; Chiang, Weiming; Lee, Haochung

    2012-09-01

    The machine tool coolers are the best managers of coolant temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine coolers are facing the compressed schedule to phase out the HCFC (hydro-chloro-floro-carbon) refrigerant and little attention has been paid to comparative study on sizing capillary tube for retrofitted HFC (hydro-floro-carbon) refrigerant. In this paper, the adiabatic flow in capillary tube is analyzed and modeled for retrofitting of HFC-407C refrigerant in a machine tool cooler system. A computer code including determining the length of sub-cooled flow region and the two phase region of capillary tube is developed. Comparative study of HCFC-22 and HFC-407C in a capillary tube is derived and conducted to simplify the traditional trial-and-error method of predicting the length of capillary tubes. Besides, experimental investigation is carried out by field tests to verify the simulation model and cooling performance of the machine tool cooler system. The results from the experiments reveal that the numerical model provides an effective approach to determine the performance data of capillary tube specific for retrofitting a HFC-407C machine tool cooler. The developed machine tool cooler system is not only directly compatible with new HFC-407C refrigerant, but can also perform a cost-effective temperature control specific for industrial machines.

  15. 120 Hz pulse tube cryocooler for fast cooldown to 50 K

    NARCIS (Netherlands)

    Vanapalli, Srinivas; Lewis, Michal; Gan, Zhihua; Radebaugh, Ray

    2007-01-01

    A pulse tube cryocooler operating at 120 Hz with 3.5 MPa average pressure achieved a no-load temperature of about 49.9 K and a cooldown time to 80 K of 5.5 min. The net refrigeration power at 80 K was 3.35 W with an efficiency of 19.7% of Carnot when referred to input pressure-volume (PV or a

  16. Prediction of condensation heat transfer of low GWP refrigerants inside smooth horizontal tube

    Science.gov (United States)

    Hossain, Md. Anowar; Afroz, Hasan M. M.; Talukder, Shaon; Miyara, Akio

    2016-07-01

    The present research work observed the experimental and analytical results of two phase condensation heat transfer of the refrigerants R1234ze(E), R32, R410A, and R1234ze(E)/R32 mixtures inside a smooth horizontal tube. A water heated double tube horizontal heat exchanger with effective length of 3.6m and inner diameter of 4.35mm is used to take place the experiment. Mass flux and the saturation temperature are the design variables under which the experiment is carried out whose values varying from the range 160 to 400 Kg m-2s-1 and 30°C to 45°C, respectively. A new correlation for pure refrigerant has been proposed to predict the heat transfer inside a smooth horizontal tube by investigating the experimental data. The newly proposed correlation and some other existing correlations of condensation heat transfer for pure refrigerant have been used to predict the condensation heat transfer of R1234ze(E), R32, R410A and dimethyl ether (DME) and compared the results. The comparison allows that the proposed model of pure refrigerant offered a better performance for all the refrigerants. All the experimental data can be predicted within a 10.2% mean deviation by using the proposed correlation.

  17. Studies on an improved indigenous pressure wave generator and its testing with a pulse tube cooler

    Science.gov (United States)

    Jacob, S.; Karunanithi, R.; Narsimham, G. S. V. L.; Kranthi, J. Kumar; Damu, C.; Praveen, T.; Samir, M.; Mallappa, A.

    2014-01-01

    Earlier version of an indigenously developed Pressure Wave Generator (PWG) could not develop the necessary pressure ratio to satisfactorily operate a pulse tube cooler, largely due to high blow by losses in the piston cylinder seal gap and due to a few design deficiencies. Effect of different parameters like seal gap, piston diameter, piston stroke, moving mass and the piston back volume on the performance is studied analytically. Modifications were done to the PWG based on analysis and the performance is experimentally measured. A significant improvement in PWG performance is seen as a result of the modifications. The improved PWG is tested with the same pulse tube cooler but with different inertance tube configurations. A no load temperature of 130 K is achieved with an inertance tube configuration designed using Sage software. The delivered PV power is estimated to be 28.4 W which can produce a refrigeration of about 1 W at 80 K.

  18. A separate two-stage pulse tube cooler working at liquid helium temperature

    Institute of Scientific and Technical Information of China (English)

    QIU Limin; HE Yonglin; GAN Zhihua; WAN Laihong; CHEN Guobang

    2005-01-01

    A novel 4 K separate two-stage pulse tube cooler (PTC) was designed and tested. The cooler consists of two separate pulse tube coolers, in which the cold end of the first stage regenerator is thermally connected with the middle part of the second regenerator. Compared to the traditional coupled multi-stage pulse tube cooler, the mutual interference between stages can be significantly eliminated. The lowest refrigeration temperature obtained at the first stage pulse tube was 13.8 K. This is a new record for single stage PTC. With two compressors and two rotary valves driving mode, the separate two-stage PTC obtained a refrigeration temperature of 2.5 K at the second stage. Cooling capacities of 508 mW at 4.2 K and 15 W at 37.5 K were achieved simultaneously. A one-compressor and one-rotary valve driving mode has been proposed to further simplify the structure of separate type PTC.

  19. New empirical correlations for sizing adiabatic capillary tubes in refrigeration systems

    Science.gov (United States)

    Shodiya, S.; Aahar, A. A.; Henry, N.; Darus, A. N.

    2012-06-01

    This paper presents new empirical correlations that have been developed for sizing adiabatic capillary tubes used in small vapor compression refrigeration and air-conditioning systems. A numerical model which is based on the basic equations of conservation of mass, momentum and energy was developed. Colebrook's formulation was used to determine the single phase friction factor. The two-phase viscosity models - Cicchitti et al., Dukler et al. and McAdam et al. were used based on the recommendation from literature to determine the two-phase viscosity factor. The developed numerical model was validated using the experimental data from literature. The numerical model was used to study the effects of relevant parameters on capillary tube length and the results showed that the length of capillary tube increase with increase in condensing temperature, subcooling, and inner diameter of tube but decrease with increase in surface roughness and mass flow rate. Thereafter, empirical correlation of the capillary tube length with the five dependent variables was presented. The empirical models are validated using experimental data from literature. Different from the previous studies, the empirical models have a large set of refrigerants and wide operating conditions. The developed correlation can be used as an effective tool for sizing adiabatic capillary tube with system models working with alternative refrigerants.

  20. CFD simulation of the gas flow in a pulse tube cryocooler with two pulse tubes

    Science.gov (United States)

    Yin, C. L.

    2015-12-01

    In this paper, in order to instruct the next optimization work, a two-dimension Computational Fluid Dynamics (CFD) model is developed to simulate temperature distribution and velocity distribution of oscillating fluid in the DPTC by individual phase-shifting. It is found that the axial temperature distribution of regenerator is generally uniform and the temperatures near the center at the same cross setion of two pulse tubes are obviously higher than their near wall temperatures. The wall temperature difference about 0-7 K exists between the two pulse tubes. The velocity distribution near the center of the regenerator is uniform and there is obvious injection stream coming at the center of the pulse tubes from the hot end. The formation reason of temperature distribution and velocity distribution is explained.

  1. Convective Boiling of Near-Azeotropic Refrigerant R410A in the Horizontal Micro-fin Tube

    Institute of Scientific and Technical Information of China (English)

    DUAN Xue-tao; MA Hu-gen; WU Zhi-min; WANG Fang

    2007-01-01

    Using near-azeotropic refrigerant R410A as the working fluid, the experimental studies on the horizontal micro-fin tubes were conducted. Several factors affecting heat transfer coefficients were analyzed, and the characteristics of flow boiling of the refrigerant in the horizontal micro-fin tubes were discussed. The local heat transfer coefficients increase with mass flux, heat flux and quality. And the heat transfer enhancement factor of those testing tubes is about 1.6 to 2.2.

  2. Helium compressor for GM and pulse-tube expanders

    Science.gov (United States)

    Longsworth, R. C.

    2002-05-01

    A new compressor system has been developed for cooling MRI magnets which has more displacement than the present compressor. By increasing the displacement from 2.9 L/s to 5.2 L/s at 60 Hz it is possible to provide more refrigeration at lower temperatures with both GM and Pulse-tube expanders. The 2.9 L/s compressor is a rolling piston type, which is cooled by water circulating through tubes bonded to the outside of the compressor shell. The 5.2 L/s compressor is a scroll type that is cooled by circulating oil to an external heat exchanger. One of the key features of the design is an oil removal system that enables the adsorber replacement interval to be increased to 5 years. A diagnostic module is incorporated in the control circuit to alert the user to an abnormal condition and show the reason for a shut down if it occurs. This paper describes essential design features and the extensive testing that has been done to characterize the compressor over a wide range of operating conditions including extremes that it might experience.

  3. Taguchi Method for Development of Mass Flow Rate Correlation using Hydrocarbon Refrigerant Mixture in Capillary Tube

    Directory of Open Access Journals (Sweden)

    Shodiya Sulaimon

    2014-07-01

    Full Text Available The capillary tube is an important control device used in small vapor compression refrigeration systems such as window air-conditioners, household refrigerators and freezers. This paper develops a non-dimensional correlation based on the test results of the adiabatic capillary tube for the mass flow rate through the tube using a hydrocarbon refrigerant mixture of 89.3% propane and 10.7% butane (HCM. The Taguchi method, a statistical experimental design approach, was employed. This approach explores the economic benefit that lies in studies of this nature, where only a small number of experiments are required and yet valid results are obtained. Considering the effects of the capillary tube geometry and the inlet condition of the tube, dimensionless parameters were chosen. The new correlation was also based on the Buckingham Pi theorem. This correlation predicts 86.67% of the present experimental data within a relative deviation of -10% to +10%. The predictions by this correlation were also compared with results in published literature.

  4. The Effect of the Capillary Tube Coil Number on the Refrigeration System Performance

    Directory of Open Access Journals (Sweden)

    Thamir K. Salim

    2012-06-01

    Full Text Available The capillary tube performance for (R134a is experimentally investigated. The experimental setup is a real vapor compression refrigeration system. All properties of the refrigeration system are measured for various mass flow rate from (13 – 23 kg/hr and capillary tube coil number (0-4 with fixed length (150 cm and capillary diameter(2.5mm.The results showed that the theoretical compression power increases by (65.8 % as the condenser temperature increases by (2.71%, also the theoretical compression power decreases by (10.3 % as the capillary tube coil number increases.The study shows also that the cooling capacity increases by (65.3% as the evaporator temperature increases by (8.4 %, and the cooling capacity increases by (1.6%as the capillary tube coil number increases in the range (0-4.The coefficient of performance decreases by (43.4 %, as the mass flow rateincreases by (76.9%, also the coefficient of performance increases by (13.51 % as thecapillary tube coil number increases in the range (0-4.Through this study, it was found that the best coil number in refrigeration cycle at the lowest mass flow rate (31 Kg/hr and at high mass flow rate (23 Kg/hr is (coil number = 4, this will give the highest performance, cooling capacity and lowest theoretical compression power.

  5. Raytheon advanced pulse-tube cryocoolers

    Science.gov (United States)

    Conrad, Ted; Yates, Ryan; Kuo, Daniel; Schaefer, Brian; Arnoult, Matt

    2016-05-01

    Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Recently, Raytheon has developed an advanced regenerator technology capable of operating efficiently at high frequencies and outperforming traditional screen regenerators. The Raytheon Advanced Miniature (RAM-100) cryocooler, a flight packaged, high frequency, single stage pulse tube cooler with an integrated surge volume and inertance tube, has been designed for use with this regenerator. Design details and experimentally measured performance of two iterations of the RAM cryocooler are presented in this paper.

  6. Fast cooldown coaxial pulse tube microcooler

    Science.gov (United States)

    Nast, T.; Olson, J. R.; Champagne, P.; Roth, E.; Kaldas, G.; Saito, E.; Loung, V.; McCay, B. S.; Kenton, A. C.; Dobbins, C. L.

    2016-05-01

    We report the development and initial testing of the Lockheed Martin first-article, single-stage, compact, coaxial, Fast Cooldown Pulse Tube Microcryocooler (FC-PTM). The new cryocooler supports cooling requirements for emerging large, high operating temperature (105-150K) infrared focal plane array sensors with nominal cooling loads of ~300 mW @105K @293K ambient. This is a sequel development that builds on our inline and coaxial pulse tube microcryocoolers reported at CEC 20137, ICC188,9, and CEC201510. The new FC-PTM and the prior units all share our long life space technology attributes, which typically have 10 year life requirements1. The new prototype microcryocooler builds on the previous development by incorporating cold head design improvements in two key areas: 1) reduced cool-down time and 2) novel repackaging that greatly reduces envelope. The new coldhead and Dewar were significantly redesigned from the earlier versions in order to achieve a cooldown time of 2-3 minutes-- a projected requirement for tactical applications. A design approach was devised to reduce the cold head length from 115mm to 55mm, while at the same time reducing cooldown time. We present new FC-PTM performance test measurements with comparisons to our previous pulse-tube microcryocooler measurements and design predictions. The FC-PTM exhibits attractive small size, volume, weight, power and cost (SWaP-C) features with sufficient cooling capacity over required ambient conditions that apply to an increasing variety of space and tactical applications.

  7. Study on a Single-Stage 120 HZ Pulse Tube Cryocooler

    Science.gov (United States)

    Wu, Y. Z.; Gan, Z. H.; Qiu, L. M.; Chen, J.; Li, Z. P.

    2010-04-01

    Miniaturization of pulse tube cryocoolers is required for some particular applications where size and mass for devices are limited. In order to pack more cooling power in a small volume, higher operating frequencies are commonly used for Stirling-type pulse tube cryocoolers. To maintain high efficiency of the regenerator with a higher frequency, a higher charging pressure, smaller hydraulic diameters of regenerator material and a shorter regenerator length should be applied. A rapid growth of research and development on pulse tube cryocoolers operating at a high frequency over 100 Hz in the last 3 years has occurred. In this study, a single stage pulse tube cryocooler with 120 Hz to provide 10 W of lift at 80 K has been developed by using the numerical model, known as REGEN 3.2. Experiments performed on this cryocooler driven by a CFIC linear compressor show that a no-load temperature of 49.6 K was achieved and the net refrigeration power at 78.5 K was 8.0 W. The effect of pulse tube orientation was tested, and the copper velvet as a regenerator matrix was proposed for high frequency operation.

  8. Heat transfer and pressure drop performance of smooth and internally finned tubes with oil and refrigerant 22 mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Schlager, L.M. (Indiana-Purdue Univ., Ft. Wayne, IN (US)); Pate, M.B. (Iowa State Univ., Ames, IA (US)); Bergles, A.E. (Rensselaer Polytechnic Inst., Troy, NY (US))

    1989-01-01

    The overall performance of a smooth tube and two augmented tubes is compared by using an enhancement performance ratio, defined as the ratio of heat transfer enhancement to pressure drop increase. The augmented tubes are compared to the smooth tube with pure R-22 and with mixtures of R-22 plus 150-or 300-SUS naphthenic mineral oil. Additionally, the performance of all three tubes with refrigerant-oil mixtures is compared to performance of the same tube with pure refrigerant. Various oil concentrations up to 5% by weight were tested and mass flux was varied from 92,000 to 294,000 lb/h{circle dot}ft{sup 2} (125 to 400 kg/m{sup 2}{circle dot}s). Nominal evaporation conditions were 37{degrees}F(3{degrees}C) with inlet and outlet qualities of 15% and 85%, respectively. The condensation conditions were 105{degrees}F (41{degrees}C) with inlet and outlet qualities of 85% and 15%, respectively. The enhancement performance ratio of the micro-fin tube is consistently higher than that of the low-fin tube with either pure refrigerant or refrigerant-oil mixtures. With pure refrigerant, the enhancement performance ratio of the augmented tubes is generally greater than unity, indicating improved performance relative to a smooth tube.

  9. Wave-shaping of pulse tube cryocooler components for improved performance

    Science.gov (United States)

    Antao, Dion Savio; Farouk, Bakhtier

    2014-11-01

    The method of wave-shaping acoustic resonators is applied to an inertance type cryogenic pulse tube refrigerator (IPTR) to improve its performance. A detailed time-dependent axisymmetric experimentally validated computational fluid dynamic (CFD) model of the PTR is used to predict its performance. The continuity, momentum and energy equations are solved for both the refrigerant gas (helium) and the porous media regions (the regenerator and the three heat-exchangers) in the PTR. An improved representation of heat transfer in the porous media is achieved by employing a thermal non-equilibrium model to couple the gas and solid (porous media) energy equations. The wave-shaped regenerator and pulse tube studied have cone geometries and the effects of different cone angles and the orientation (nozzle v/s diffuser mode) on the system performance are investigated. The resultant spatio-temporal pressure, temperature and velocity fields in the regenerator and pulse tube components are evaluated. The performance of these wave-shaped PTRs is compared to the performance of a non wave-shaped system with cylindrical components. Better cooling is predicted for the cryocooler using wave-shaped components oriented in the diffuser mode.

  10. Inertance Tube Modeling and the Effects of Temperature

    Science.gov (United States)

    2010-01-01

    compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction Rev. Sci. Instrum. 83, 095102...acoustic power. KEYWORDS: Inertance tube, cryocoolers, pulse tube refrigerators, oscillating flow, computational fluid dynamics INTRODUCTION Pulse

  11. Real gas features on the performance of pulse tube cryocoolers

    Science.gov (United States)

    Ju, Y. L.

    2002-05-01

    The working helium gas in a pulse tube cryocooler operating at temperatures down to 80 K is mainly assumed to be an ideal gas. Therefore, the time-variations of the temperature profiles and the position of the gas element traveling with pressure oscillations inside the pulse tube can be readily determined by the law of Poisson function. However, this is certainly invalid for the pulse tube cryocooler operating at temperature range of liquid helium, in which the thermal properties of the helium gas change drastically. The temperature profiles in the regenerator and the pulse tube are strongly affected by the real thermal properties of the helium gas. We derive in this paper, the respective expressions to follow the tracks of the gas elements as they move in the pulse tube, and to reveal the time dependence of the temperature profiles and the position of gas elements traveling with the pressure oscillations inside the pulse tube. The approach is based on the thermodynamic equations for the real gas. We will show that contrary to the ideal gas case there is another term which determines the dynamic behaviors of the temperature distributions and the position of the gas elements. A typical calculation is presented for visualizing the time dependence of the cooling-down processes of the temperature profiles in the pulse tube of a 4K two-stage pulse tube cryocooler from room temperature down to low temperature.

  12. Performance improvement of double-tube gas cooler in CO2 refrigeration system using nanofluids

    Directory of Open Access Journals (Sweden)

    Sarkar Jahar

    2015-01-01

    Full Text Available The theoretical analyses of the double-tube gas cooler in transcritical carbon dioxide refrigeration cycle have been performed to study the performance improvement of gas cooler as well as CO2 cycle using Al2O3, TiO2, CuO and Cu nanofluids as coolants. Effects of various operating parameters (nanofluid inlet temperature and mass flow rate, CO2 pressure and particle volume fraction are studied as well. Use of nanofluid as coolant in double-tube gas cooler of CO2 cycle improves the gas cooler effectiveness, cooling capacity and COP without penalty of pumping power. The CO2 cycle yields best performance using Al2O3-H2O as a coolant in double-tube gas cooler followed by TiO2-H2O, CuO-H2O and Cu-H2O. The maximum cooling COP improvement of transcritical CO2 cycle for Al2O3-H2O is 25.4%, whereas that for TiO2-H2O is 23.8%, for CuO-H2O is 20.2% and for Cu-H2O is 16.2% for the given ranges of study. Study shows that the nanofluid may effectively use as coolant in double-tube gas cooler to improve the performance of transcritical CO2 refrigeration cycle.

  13. Pulse tube cooler having 1/4 wavelength resonator tube instead of reservoir

    Science.gov (United States)

    Gedeon, David R. (Inventor)

    2008-01-01

    An improved pulse tube cooler having a resonator tube connected in place of a compliance volume or reservoir. The resonator tube has a length substantially equal to an integer multiple of 1/4 wavelength of an acoustic wave in the working gas within the resonator tube at its operating frequency, temperature and pressure. Preferably, the resonator tube is formed integrally with the inertance tube as a single, integral tube with a length approximately 1/2 of that wavelength. Also preferably, the integral tube is spaced outwardly from and coiled around the connection of the regenerator to the pulse tube at a cold region of the cooler and the turns of the coil are thermally bonded together to improve heat conduction through the coil.

  14. Innovative phase shifter for pulse tube operating below 10 K

    Science.gov (United States)

    Duval, Jean-Marc; Charles, Ivan; Daniel, Christophe; André, Jérôme

    2016-09-01

    Stirling type pulse tubes are classically based on the use of an inertance phase shifter to optimize their cooling power. The limitations of the phase shifting capabilities of these inertances have been pointed out in various studies. These limitations are particularly critical for low temperature operation, typically below about 50 K. An innovative phase shifter using an inertance tube filled with liquid, or fluid with high density or low viscosity, and separated by a sealed metallic diaphragm has been conceived and tested. This device has been characterized and validated on a dedicated test bench. Operation on a 50-80 K pulse tube cooler and on a low temperature (below 8 K) pulse tube cooler have been demonstrated and have validated the device in operation. These developments open the door for efficient and compact low temperature Stirling type pulse tube coolers. The possibility of long life operation has been experimentally verified and a design for space applications is proposed.

  15. Solar refrigerating unit with an adsorption reactor and evacuated tube collectors

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, M.E.; Moreira, H.B.C. [Ceara Univ., Fortaleza, CE (Brazil). Dept. de Engenharia Quimica. Lab. de Energia Solar Aplicada

    1997-09-01

    This work presents the principles of operation of a solar refrigerator with the following basic components: a reactor, a set of evacuated tube solar collectors, a condenser, a heat exchanger, and an evaporator. During the heating phase, solar radiation is collected and transferred to the reactor for desorption by a vapor thermal siphon loop. During the cooling phase, heat from the reactor is released to the ambient by a second water vapor loop. Ambient data collected daily during a period of 18 years were divided into hourly values and used to simulate the temperatures of the reactors, which uses salt impregnated with graphite and ammonia, during the adsorption / desorption processes. The results show that the refrigerator operates well in Fortaleza and that better results are expected from the countryside of the state of Ceara. It is concluded that only a high efficiency collector set can be used in the system. (author) 10 refs., 4 figs.; e-mail: eugenia at ufc.br

  16. SOLAR REFRIGERATING UNIT WITH AN ADSORPTION REACTOR AND EVACUATED TUBE COLLECTORS

    Directory of Open Access Journals (Sweden)

    M.E. Vieira

    1997-09-01

    Full Text Available This work presents the principles of operation of a solar refrigerator with the following basic components: a reactor, a set of evacuated tube solar collectors, a condenser, a heat exchanger, and an evaporator. During the heating phase, solar radiation is collected and transferred to the reactor for desorption by a vapor thermal siphon loop. During the cooling phase, heat from the reactor is released to the ambient by a second water vapor loop. Ambient data collected daily during a period of 18 years were divided into hourly values and used to simulate the temperatures of the reactor, which uses salt impregnated with graphite and ammonia, during the adsorption / desorption processes. The results show that the refrigerator operates well in Fortaleza and that better results are expected for the countryside of the state of Ceara. It is concluded that only a high efficiency collector set can be used in the system

  17. A 300 Hz high frequency thermoacoustically driven pulse tube cooler

    Institute of Scientific and Technical Information of China (English)

    ZHU ShangLong; YU GuoYao; ZHANG XiaoDong; DAI Wei; LUO ErCang; ZHOU Yuan

    2008-01-01

    This article introduces the latest progress of a 300 Hz thermoacoustically driven pulse tube cooler. Based on the experience of former experiments, improvements have been made in the standing-wave engine, pulse tube cooler and their coupling mechanism. An inlet pressure ratio of 1.248 was obtained with the mean pressure and heating power of 4.13 MPa and 1760 W, respectively. A lowest no-load temperature of 69.5 K has been reached under this condition. This is the first time for thermoacousti-cally driven pulse tube coolers to reach the temperature below 76 K with such a high frequency.

  18. Experimental analysis of refrigerants flow boiling inside small sized microfin tubes

    Science.gov (United States)

    Diani, Andrea; Rossetto, Luisa

    2017-07-01

    The refrigerant charge reduction is one of the most challenging issues that the scientific community has to cope to reduce the anthropic global warming. Recently, mini microfin tubes have been matter of research, since they can reach better thermal performance in small domains, leading to a further refrigerant charge reduction. This paper presents experimental results about R134a flow boiling inside a microfin tube having an internal diameter at the fin tip of 2.4 mm. The mass flux was varied between 375 and 940 kg m-2 s-1, heat flux from 10 to 50 kW m-2, vapor quality from 0.10 to 0.99. The saturation temperature at the inlet of the test section was kept constant and equal to 30 °C. R134a thermal and fluid dynamic performances are presented and compared against those obtained with R1234ze(E) and R1234yf and against values obtained during R134a flow boiling inside a 3.4 mm ID microfin tube.

  19. Boiling heat-transfer coefficient variation for R407C inside horizontal tubes of a refrigerating vapour-compression plant's shell-and-tube evaporator

    Energy Technology Data Exchange (ETDEWEB)

    Torrella, Enrique [Department of Applied Thermodynamics, Camino de Vera, 14, Polytechnic University of Valencia, E-46022 Valencia (Spain); Navarro-Esbri, Joaquin; Cabello, Ramon [Department of Technology, Campus de Riu Sec,University Jaume I, E-12071 Castellon (Spain)

    2006-03-01

    The present paper presents experimental results obtained from a refrigerating vapour-compression plant's shell-and-tube (1-2) evaporator working with R407C. Several tests have been carried out to study the influence of the evaporating pressure and the refrigerant's mass flow rate on the refrigerant's boiling heat-transfer coefficient inside horizontal tubes. This work has been performed by analyzing the variations of the evaporator's overall thermal-resistance, computed using the effectiveness-NTU method, considering the influence of pressure drops and glide at the evaporator, and finally transferring the results and conclusions to the boiling heat-transfer coefficient. It has been observed that the variations of the boiling heat-transfer coefficient show a dependence on the evaporating temperature and the refrigerant's mass-flow rate, which has been analyzed in the test range. [Author].

  20. An Optical Cryostat for Use in Microscopy Cooled by Stirling-Type Pulse Tube Cryocooler

    Science.gov (United States)

    Liubiao, Chen; Qiang, Zhou; Xiaoshuang, Zhu; Yuan, Zhou; Junjie, Wang

    The few products of an optical cryostat for use in microscopy in commercialapplications are generally cooled by liquid nitrogen, liquid helium or cryocoolers such as G-M cryocooler or G-M type pulse tube cryocooler (PTC). Sometimes it is not convenient to use G-M cryocooler or G-M type PTC because of its noise and big size; and in some places, liquid nitrogen, especially liquid helium, is not easily available. To overcome this limitation, an optical cryostat for use in microscopy cooled by a Stirling-type pulse tube cryocooler (SPTC) has been designed, built and tested. The refrigerator system SPTC is an important component of the optical cryostat; it has the advantages of compactness, high efficiency, and low vibration. For simplification and compactness, single-stage configuration with coaxial arrangement was employed in the developed SPTC. In order to lower the vibration, the separated configuration was adopted; its compressor and pulse tube are connected with a flexible connecting tube. At present, a lowest temperature of 20 K could be achieved. The temperature fluctuation can be controlled at ±10 mK by adjusting the input electric power to the compressor; and some considerations for further improvement will also be described in this paper.

  1. An experimental study of the flow of LPG as refrigerant inside an adiabatic helical coiled capillary tube in vapour compression refrigeration system

    Science.gov (United States)

    Punia, Sanjeev Singh; Singh, Jagdev

    2015-11-01

    This paper presents an experimental investigation for the flow of liquefied petroleum gas (LPG) as a refrigerant inside an adiabatic helically coiled capillary tube in vapour compression refrigeration system. The effect of various geometric parameters and operating conditions like capillary tube inner diameter, length of capillary tube, coil diameter and different inlet subcoolings on the mass flow rate of LPG through the helical coiled capillary tube geometry has been investigated. It has been established that the coil diameter significantly influences the mass flow rate of LPG through the adiabatic helical capillary tube. It has been concluded that the effect of coiling of capillary tube reduces the mass flow rate by 5-12 % as compared to those of the straight capillary tube operating under similar conditions. The data obtained from the experiments are analyzed and a dimensionless correlation has been developed. The proposed correlation predicts that more than 90 % of experimental data which is in agreement with measured data in an error band of ±10 %.

  2. Propellant Conditioning Using Improved Pulse Tube Cryocooler Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Application of the proposed technology (an affordable, large-scale, high-efficiency, low-temperature pulse tube cryocooler system), serves two NASA needs: an...

  3. The third type DC flow in pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yuan; GU Chao; CAI HuiKun

    2009-01-01

    New phenomena discovered in the experimental research of the ultra-high frequency pulse tube cryo cooler were presented.The cause of the new phenomena was analyzed and the third type DC flow was discovered in the pulse tube cryocooler.The third type DC flow not only deteriorated cooling capacity but also led to temperature instability of the pulse tube cryocooler.From the fluid network theory and the simple regenerator model,the root of the third type DC flow was concisely investigated in theory.The asymmetric resistance of oscillating flow in pulse tube cryocooler was the key mechanism of the third type DC flow.Some suppression methods were briefly discussed.

  4. The third type DC flow in pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    New phenomena discovered in the experimental research of the ultra-high frequency pulse tube cryocooler were presented.The cause of the new phenomena was analyzed and the third type DC flow was discovered in the pulse tube cryocooler.The third type DC flow not only deteriorated cooling capacity but also led to temperature instability of the pulse tube cryocooler.From the fluid network theory and the simple regenerator model,the root of the third type DC flow was concisely investigated in theory. The asymmetric resistance of oscillating flow in pulse tube cryocooler was the key mechanism of the third type DC flow.Some suppression methods were briefly discussed.

  5. Large co-axial pulse tube preliminary results

    Science.gov (United States)

    Emery, N.; Caughley, A.; Meier, J.; Nation, M.; Tanchon, J.; Trollier, T.; Ravex, A.

    2014-01-01

    We report that Callaghan Innovation, formally known as Industrial Research Ltd (IRL), has designed and built its largest of three high frequency single-stage co-axial pulse tubes, closely coupled to a metal diaphragm pressure wave generator (PWG). The previous pulse tube achieved 110 W of cooling power @ 77 K, with an electrical input power of 3.1 kW from a 90 cc swept volume PWG. The pulse tubes have all been tuned to operate at 50 Hz, with a mean helium working pressure of 2.5 MPa. Sage pulse tube simulation software was used to model the latest pulse tube and predicted 280 W of cooling power @ 77 K. The nominal 250 W cryocooler was designed to be an intermediate step to up-scale pulse tube technology for our 1000 cc swept-volume PWG, to provide liquefaction of gases and cooling for HTS applications. Details of the modeling, design, development and preliminary experimental results are discussed.

  6. Low temperature high frequency coaxial pulse tube for space application

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Aurelia; Charles, Ivan; Rousset, Bernard; Duval, Jean-Marc [SBT, UMR-E CEA / UJF-Grenoble 1, INAC, 17, rue des Martyrs, Grenoble, F-38054 (France); Daniel, Christophe [CNES, 18, avenue Edouard Belin, Toulouse, F-31401 (France)

    2014-01-29

    The 4K stage is a critical step for space missions. The Hershel mission is using a helium bath, which is consumed day by day (after depletion, the space mission is over) while the Plank mission is equipped with one He4 Joule-Thomson cooler. Cryogenic chain without helium bath is a challenge for space missions and 4.2K Pulse-Tube working at high frequency (around 30Hz) is one option to take it up. A low temperature Pulse-Tube would be suitable for the ESA space mission EChO (Exoplanet Characterisation Observatory, expected launch in 2022), which requires around 30mW cooling power at 6K; and for the ESA space mission ATHENA (Advanced Telescope for High ENergy Astrophysics), to pre-cool the sub-kelvin cooler (few hundreds of mW at 15K). The test bench described in this paper combines a Gifford-McMahon with a coaxial Pulse-Tube. A thermal link is joining the intercept of the Pulse-Tube and the second stage of the Gifford-McMahon. This intercept is a separator between the hot and the cold regenerators of the Pulse-Tube. The work has been focused on the cold part of this cold finger. Coupled with an active phase shifter, this Pulse-Tube has been tested and optimized and temperatures as low as 6K have been obtained at 30Hz with an intercept temperature at 20K.

  7. A vibration free closed-cycle 1 K cryostat with a 4 K pulse tube cryocooler

    Science.gov (United States)

    Wang, Chao; Lichtenwalter, Ben

    2014-01-01

    A 1 K closed-cycle cryostat, pre-cooled by a 4 K pulse tube cryocooler, has been developed. The Cryomech PT410 pulse tube cryocooler liquefies helium in a vacuum insulated sleeve at a pressure of ˜1 atm. Liquid helium flows through a JT valve and into a 1 K pot that is evacuated by a vacuum pump. The discharged gas from the vacuum is routed to the top of the sleeve to be liquefied. This design accomplishes closed-cycle 1 K refrigeration and provides continuous cooling below 2 K. Using two XDS10 vacuum pumps and with the JT valve optimized for maximum cooling capacity, the 1 K cooling station can reach a no-load temperature of 1.51 K and provide a capacity of 225 mW at 1.76 K. The temperature oscillations on the 4 K and 1 K cooling stations are ± 3 mK. The cryostat is designed so that there is no direct mechanical contact between the pulse tube cryocooler heat exchangers and the 1 K cooling station. This design feature enables exceptionally low vibration operation at the 1 K cooling station.

  8. Parametric Study of High Frequency Pulse Detonation Tubes

    Science.gov (United States)

    Cutler, Anderw D.

    2008-01-01

    This paper describes development of high frequency pulse detonation tubes similar to a small pulse detonation engine (PDE). A high-speed valve injects a charge of a mixture of fuel and air at rates of up to 1000 Hz into a constant area tube closed at one end. The reactants detonate in the tube and the products exit as a pulsed jet. High frequency pressure transducers are used to monitor the pressure fluctuations in the device and thrust is measured with a balance. The effects of injection frequency, fuel and air flow rates, tube length, and injection location are considered. Both H2 and C2H4 fuels are considered. Optimum (maximum specific thrust) fuel-air compositions and resonant frequencies are identified. Results are compared to PDE calculations. Design rules are postulated and applications to aerodynamic flow control and propulsion are discussed.

  9. Numerical and Experimental Study on Contact Face and Shock Wave Motion in the Receiving Tube of Gas Wave Refrigerator

    Institute of Scientific and Technical Information of China (English)

    Dapeng HU; Shengtao CHEN; Hu LIU; Zuzhi CHEN; Che ZHU

    2006-01-01

    The contact face and shock wave motion in an open ends receiving tube of gas wave refrigerator are investigated numerically and experimentally.The results show that,velocity of the contact face rises rapidly as gas is injected into the receiving tube,and drops sharply after a steady propagation.However,velocity of the shock wave in the tube is almost linear.With increasing of inlet pressure,velocity of the shock wave and steady velocity of contact face also increase.In addition,time and distance of contact face propagation in the receiving tube become longer.

  10. Cold Inertance Tube for 4 K Stirling Type Pulse Tube Cryocoolers

    Science.gov (United States)

    Li, ZhuoPei; Gan, ZhiHua; Qiu, LiMin

    The losses in the regenerator are minimized when the amplitude of the mass flow is minimized for a given acoustic power which requires that the mass flow lags the pressure by about 30° at the cold end of regenerator. The phase shift provided by an inertance tube is strongly influenced by the temperature of the inertance tube and the acoustic power at the cold end of the regenerator. For a 4 K Stirling type pulse tube cryocooler, the acoustic power at the cold end of the regenerator decreases significantly with the temperature thereby it's difficult to achieve ideal phase relationship with ambient inertance tube. While cold inertance tube provide a larger phase shift in that the viscosity of the working fluid decreases and the density increases as the temperature decreases. However, use of cold inertance tube increases additional heat load to the regenerator. Therefore it's of great significance to determine when a cold inertance tube should be used. In this paper effect of temperature of inertance tube is calculated for a 4 K Stirling type pulse tube cryocooler with different acoustic powers at the cold end. A comparison of ambient temperature inertance tube and cold inertance tube is made.

  11. Air Liquide's pulse tube cryocooler systems for space applications

    Science.gov (United States)

    Trollier, T.; Tanchon, J.; Rey, J. C.; Ravex, A.; Buquet, J.

    2009-05-01

    Thanks to important development efforts completed internally and with the European Space Agency (ESA) funding, Air Liquide Advanced Technology Division (AL/DTA) is now in position to propose two Pulse Tube cooler systems in the 40-80K temperature range for coming Earth Observation missions such as Meteosat Third Generation (MTG), SIFTI, etc... The Miniature Pulse Tube Cooler (MPTC) is lifting up to 2.47W@80K with 50W maximal compressor input power and 10°C rejection temperature. The weight is 2.8 kg. The Large Pulse Tube Cooler (LPTC) is providing 2.3W@50K for 160W input power and 10°C rejection temperature. This product is weighing 5.1 kg. The two pulse tube coolers thermo-mechanical units are qualified against environmental constraints as per ESA ECSS-E-30. They are both using dual opposed pistons flexure bearing compressor with moving magnet linear motors in order to ensure very high lifetime. The associated Cooler Drive Electronics is also an important aspect specifically regarding the active control of the cooler thermo-mechanical unit during the launch phase and the active reduction of the vibrations induced by the compressor (partly supported by the French Agency CNES). This paper details the presentation of the two Pulse Tube Coolers together with the Cooler Drive Electronics aspects.

  12. A high efficiency hybrid stirling-pulse tube cryocooler

    Science.gov (United States)

    Wang, Xiaotao; Zhang, Yibing; Li, Haibing; Dai, Wei; Chen, Shuai; Lei, Gang; Luo, Ercang

    2015-03-01

    This article presented a hybrid cryocooler which combines the room temperature displacers and the pulse tube in one system. Compared with a traditional pulse tube cryocooler, the system uses the rod-less ambient displacer to recover the expansion work from the pulse tube cold end to improve the efficiency while still keeps the advantage of the pulse tube cryocooler with no moving parts at the cold region. In the meantime, dual-opposed configurations for both the compression pistons and displacers reduce the cooler vibration to a very low level. In the experiments, a lowest no-load temperature of 38.5 K has been obtained and the cooling power at 80K was 26.4 W with an input electric power of 290 W. This leads to an efficiency of 24.2% of Carnot, marginally higher than that of an ordinary pulse tube cryocooler. The hybrid configuration herein provides a very competitive option when a high efficiency, high-reliability and robust cryocooler is desired.

  13. A high efficiency hybrid stirling-pulse tube cryocooler

    Directory of Open Access Journals (Sweden)

    Xiaotao Wang

    2015-03-01

    Full Text Available This article presented a hybrid cryocooler which combines the room temperature displacers and the pulse tube in one system. Compared with a traditional pulse tube cryocooler, the system uses the rod-less ambient displacer to recover the expansion work from the pulse tube cold end to improve the efficiency while still keeps the advantage of the pulse tube cryocooler with no moving parts at the cold region. In the meantime, dual-opposed configurations for both the compression pistons and displacers reduce the cooler vibration to a very low level. In the experiments, a lowest no-load temperature of 38.5 K has been obtained and the cooling power at 80K was 26.4 W with an input electric power of 290 W. This leads to an efficiency of 24.2% of Carnot, marginally higher than that of an ordinary pulse tube cryocooler. The hybrid configuration herein provides a very competitive option when a high efficiency, high-reliability and robust cryocooler is desired.

  14. Helium liquefaction with a 4 K pulse tube cryocooler

    Science.gov (United States)

    Wang, Chao

    2001-07-01

    Helium liquefaction with a two-stage 4 K pulse tube cryocooler is introduced in this paper. The helium liquefier has a feature of precooling helium gas to be liquefied by using inefficiency of the second stage regenerator in the pulse tube cryocooler. This process reduces enthalpy of the incoming helium gas when entering the condenser and significantly increases the condensation rate. Numerical analysis predicts the precooling heat load on the second stage regenerator, decreases the PTC second stage cooling capacity by only 11% of the heat actually absorbed into the regenerator. A prototype pulse tube helium liquefier was built, which has two precooling heat exchangers on the first stage cold head and the second stage regenerator. It continuously liquefies helium with a rate of 4.8 l/day under normal pressure while consumes 4.6 kW power input.

  15. Measurement and correlation of frictional pressure drop of refrigerant-based nanofluid flow boiling inside a horizontal smooth tube

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Hao; Ding, Guoliang; Jiang, Weiting; Hu, Haitao [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, 800 Dongchuan Road, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, 381 Huaihaizhong Road, Shanghai 200020 (China)

    2009-11-15

    The objective of this paper is to investigate the effect of nanoparticle on the frictional pressure drop characteristics of refrigerant-based nanofluid flow boiling inside a horizontal smooth tube, and to present a correlation for predicting the frictional pressure drop of refrigerant-based nanofluid. R113 refrigerant and CuO nanoparticle were used for preparing refrigerant-based nanofluid. Experimental conditions include mass fluxes from 100 to 200 kg m{sup -2} s{sup -1}, heat fluxes from 3.08 to 6.16 kW m{sup -2}, inlet vapor qualities from 0.2 to 0.7, and mass fractions of nanoparticles from 0 to 0.5 wt%. The experimental results show that the frictional pressured drop of refrigerant-based nanofluid increases with the increase of the mass fraction of nanoparticles, and the maximum enhancement of frictional pressure drop is 20.8% under above conditions. A frictional pressure drop correlation for refrigerant-based nanofluid is proposed, and the predictions agree with 92% of the experimental data within the deviation of {+-}15%. (author)

  16. Numerical Study of a 10 K Two Stage Pulse Tube Cryocooler with Precooling Inside the Pulse Tube

    Science.gov (United States)

    Xiaomin, Pang; Xiaotao, Wang; Wei, Dai; Jianyin, Hu; Ercang, Luo

    2017-02-01

    High efficiency cryocoolers working below 10 K have many applications such as cryo-pump, superconductor cooling and cryogenic electronics. This paper presents a thermally coupled two-stage pulse tube cryocooler system and its numeric analysis. The simulation results indicate that temperature distribution in the pulse tube has a significant impact on the system performance. So a precooling heat exchanger is put inside the second stage pulse tube for a deep investigation on its influence on the system performance. The influences of operating parameters such as precooling temperature, location of the precooling heat exchanger are discussed. Comparison of energy losses apparently show the advantages of the configuration which leads to an improvement on the efficiency. Finally, the cryocooler is predicted to be able to reach a relative Carnot efficiency of 10.7% at 10 K temperature.

  17. Development of the LPT9510 1 W Concentric Pulse Tube

    Science.gov (United States)

    Mullié, J. C.; Bruins, P. C.; Benschop, T.; Charles, I.; Coynel, A.; Duband, L.

    2006-04-01

    In order to provide cryogenic cooling for applications that are extremely sensitive to mechanical vibration, Thales Cryogenics has been delivering U-shape pulse tube cryocoolers since 2001. The disadvantage of the U-shape design is that the available regenerator volume is too limited if the application puts constrains on the overall diameter of the cold finger, thus limiting the coolers efficiency. As presented at CEC/ICMC 2003, Thales Cryogenics and CEA/SBT have achieved very good results with a large concentric pulse tube delivering 4W @ 77K driven by a flexure bearing compressor. Furthermore, the same team, together with Air Liquide DTA, developed a very efficient 1W pulse tube cooler for the ESA MPTC project. Based on the experiences obtained with those programs, Thales Cryogenics and CEA/SBT have now developed a small concentric pulse tube that is driven by a flexure bearing compressor. The result is a very compact and reliable cooler, with an efficiency that is nearly doubled compared to the U-shape version with the same overall external diameter dimensions. This paper describes the trade-offs that have been considered in the design phase, and gives a detailed overview of the test results, the status of the qualification program and a comparison with a comparable Stirling cold finger.

  18. 15 K pulse tube design for ECHO mission

    Science.gov (United States)

    Duval, J. M.; Charles, I.; Chassaing, C.; Butterworth, J.; Aigouy, G.; Mullié, J.

    2014-01-01

    The Exoplanet Characterisation Observatory (EChO) is a proposed space telescope designed to characterize the atmospheres of nearby transiting exoplanets. Its detectors will operate in the 0.4 to 11 micromillimeter range. Two kinds of detectors are currently able to provide the desired sensitivity in this range. Depending on the technology used, cooling to either 6 K or about 30 K will be required. For the former solution, a JT cooler coupled to a pulse tube cooler could be used whereas for the latter, a pulse tube cooler would provide the cooling power. Pulse tube coolers are particularly well adapted for the cryogenics for such mission because of the low level of vibration required and of the temperature range. We developed multistage pulse tube coolers able to cool down to temperature as low as 6 K, with efficient operation from 10 K to 40 K. A design based on our tested prototypes is proposed to fulfill the need for the ECHO missions. This paper describes the experimental results measured with demonstrator models. In particular measured performances of efficient cooling power at 10 K are presented. Several possible configurations for the ECHO cooler will be discussed as well.

  19. Numerical analysis of stirling type pulse tube cryocoolers

    Science.gov (United States)

    Boroujerdi, A. A.; Ashrafizadeh, A.; Mousavi Naeenian, S. M.

    2011-09-01

    A one-dimensional finite volume discretization method is proposed and is implemented as a computer program for the modeling of a family of stirling type Pulse Tube Cryocoolers (PTC). The set of unsteady, one-dimensional, viscous compressible flow equations are written in a general form such that all, porous and non-porous, sections of the PTC can be modeled with these governing equations. In present work, temperature dependency of thermo-physical properties are taken into account as well as the heat transfer between the working fluid and the solid parts, and heat conductions of the gas and solid. The simulation tool can be used to model both the inertance tube type and the orifice type cryocoolers equipped with regenerators made up of different matrix constructions. The PTC might have an arbitrary orientation with respect to the gravitational field. By using the computer program, an orifice type and an inertance tube type pulse tube cryocooler are simulated. Diameter of the orifice and length of the inertance tube are optimized in order to maximize the coefficient of performance. Furthermore, the cooling power of the two types is obtained as a function of the cooling temperature. The behavior of thermodynamic parameters of the inertance tube PTC is investigated. Mean cyclic values of the parameters are presented.

  20. DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER

    Institute of Scientific and Technical Information of China (English)

    JIANGYan-long; CHENGuo-bang; THUMMESGuenter

    2004-01-01

    An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively.

  1. Experimental study on a co-axial pulse tube cryocooler driven by a small thermoacoustic stirling engine

    Science.gov (United States)

    Chen, M.; Ju, L. Y.; Hao, H. X.

    2014-01-01

    Small scale thermoacoustic heat engines have advantages in fields like space exploration and domestic applications considering small space occupation and ease of transport. In the present paper, the influence of resonator diameter on the general performance of a small thermoacoustic Stirling engine was experimentally investigated using helium as the working gas. Reducing the diameter of the resonator appropriately is beneficial for lower onset heating temperature, lower frequency and higher pressure amplitude. Based on the pressure distribution in the small thermoacoustic engine, an outlet for the acoustic work transmission was made to combine the engine and a miniature co-axial pulse tube cooler. The cooling performance of the whole refrigeration system without any moving part was tested. Experimental results showed that further efforts are required to optimize the engine performance and its match with the co-axial pulse tube cooler in order to obtain better cooling performance, compared with its original operating condition, driven by a traditional electrical linear compressor.

  2. Sealed tube comparisons of the compatibility of desiccants with refrigerants and lubricants. Final report, August 1993--January 1995

    Energy Technology Data Exchange (ETDEWEB)

    Field, J.E.

    1995-05-01

    Continuing environmental concerns mandate replacement of CFC`s with alternate refrigeration fluids. Until now, relatively little testing had been reported in the literature for compatibility of desiccants in these new working fluids. Using bench scale test methods generally accepted throughout the industry today, this work provides data necessary to assess the compatibility of virtually all of the currently used desiccant types - both bead and molded core, with thirteen refrigerant/lubricant combinations. The desiccants have been tested by exposure to refrigerant and lubricant in sealed, glass tubes in accordance with ASHRAE/ANSI Standard 97-1989. After aging, the liquid phase was evaluated for acid anion formation, change in color, and presence of halide ions, the gas phase was analyzed for refrigerant decomposition by gas chromatography, and the desiccants were evaluated for changes in crush strength and for retention of acids and halide ions. Metal catalysts, also present in the sealed tubes, were visually examined for corrosion, copper plating, and appearance changes.

  3. Impedance magnitude optimization of the regenerator in Stirling pulse tube cryocoolers working at liquid-helium temperatures

    Science.gov (United States)

    Cao, Q.; Qiu, L. M.; Zhi, X. Q.; Han, L.; Gan, Z. H.; Zhang, X. B.; Zhang, X. J.; Sun, D. M.

    2013-12-01

    The impedance magnitude is important for the design and operation of a Stirling pulse tube cryocooler (SPTC). However, the influence of the impedance magnitude on the SPTC working at liquid-helium temperatures is still not clear due to the complexity of refrigeration mechanism at this temperature range. In this study, the influence of the impedance magnitude on the viscous and thermal losses has been investigated, which contributes to the overall refrigeration efficiency. Different from the previous study at liquid nitrogen temperatures, it has been found and verified experimentally that a higher impedance magnitude may result in a larger mass flow rate accompanied with larger losses in the warmer region, hence the refrigeration efficiency is lowered. Numerical simulation is carried out in SPTCs of different geometry dimensions and working parameters, and the experimental study is carried out in a three-stage SPTC. A minimum no-load refrigeration temperature is achieved with an appropriate impedance magnitude that is determined by the combination of frequency and precooling temperature. A lowest temperature of 4.76 K is achieved at 28 Hz and a precooling temperature of 22.6 K, which is the lowest temperature ever achieved with He-4 for SPTCs. Impedance magnitude optimization is clearly an important consideration for the design of a 4 K SPTC.

  4. Investigation of casing inspection through tubing with pulsed eddy current

    Science.gov (United States)

    Fu, Yuewen; Yu, Runqiao; Peng, Xuewen; Ren, Shangkun

    2012-12-01

    Corrosion and cracks of casing string in oil wells is a serious problem on which little research has been done when inspecting casing through tubing. In this study, inspecting casing through tubing with pulsed eddy current is investigated. Longitudinal and transverse probes are centred inside the tubing to detect wall thinnings and cracks in casing. A time slice of induced voltage in the receiving coil of the probe is used as the feature to recognise defects. The experimental results show that large area wall thinnings and long cracks in casing are detected successfully through the tubing with appropriate inspection parameters. The probe's orientation to the crack is important and a particular discovery is that the transverse probe should be parallel to the transverse crack and not be perpendicular to it when inspecting. A method based on linear regression is proposed to estimate flaws in casing while wall thinning in the tubing occurs at the same location. The method is effective for large area thinning in casing when tubing thinning is wide.

  5. New Regenerator Materials for use in pulse tube coolers

    Energy Technology Data Exchange (ETDEWEB)

    A. Kashani; B.P.M. Helvensteijn; P. Kittel; K.A. Gschneidner,jr; V.K. Pecharsky; A.O. Pecharsky

    2004-09-30

    A two-stage pulse tube cooler driven by a linear compressor is being developed to provide cooling at 20 K. The first stage of the cooler will have the conventional stainless steel screen regenerator matrix. The matrix for the second stage regenerator (<60 K) will be made from a new class of Er based alloys which was recently developed at Ames Laboratory, in Ames, Iowa. These alloys exhibit heat capacities that exceed that of all other materials, including lead, over a Wide range in temperature (15 K < T C 85 K). The performance of one such alloy was shown to be better than lead when tested in a single-stage pulse tube cooler driven by a G-M compressor and operating at 2 Hz. An effort is underway to establish their suitability at frequencies above 40 IIZ. An approach to testing these alloys at low temperatures while using a low-power linear compressor is presented.

  6. Performance Limits of Pulse Tube Cryocoolers Using 3HE

    Science.gov (United States)

    Kittel, P.

    2008-03-01

    The enthalpy, entropy, and exergy flows resulting from the real gas effects of 3He in ideal pulse tube cryocoolers are described. The discussion follows a previous description of the real gas effects of 4He in ideal pulse tube cryocoolers and makes use of a recently developed model of the thermophysical properties of 3He. This model is used to describe how the thermodynamic flows are affected by real gas phenomena of 3He and compares these effects to similar effects for 4He. The analysis was done over the pressure range 0.3-2 MPa and temperatures down to 1 K. At 2 MPa there is almost no difference in the cooling power between 3He and 4He. At lower pressures, using 3He is advantageous. There is a 1-2 K reduction in the 3He cooling power vs. temperature curves compared to those for 4He in the 0.3-1 MPa range.

  7. Light pulses to photomultiplier tubes from extended scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Albergo, S. [Catania Univ. (Italy). Ist. di Fisica; Boemi, D. [CSFNeSM, I-95129 Catania (Italy); Caccia, Z. [Catania Univ. (Italy). Ist. di Fisica; Costa, S. [Catania Univ. (Italy). Ist. di Fisica; Insolia, A. [Catania Univ. (Italy). Ist. di Fisica; Panebianco, S. [Catania Univ. (Italy). Ist. di Fisica; Potenza, R. [Catania Univ. (Italy). Ist. di Fisica; Randazzo, N. [Catania Univ. (Italy). Ist. di Fisica; Reito, S. [Catania Univ. (Italy). Ist. di Fisica; Romanski, J. [The Svedberg Laboratory, University of Uppsala, S751-21 Uppsala (Sweden); Russo, G.V. [Catania Univ. (Italy). Ist. di Fisica; Tuve, C. [Catania Univ. (Italy). Ist. di Fisica

    1995-08-15

    Light pulses seen by photomultiplier tubes (PMTs) after propagation within long scintillator slats or rods, or large disc-shaped scintillators are investigated and compared with those from point-like scintillators. Results of experimental tests for the disc-shaped configuration, performed with the single photon counting technique, are presented and compared with numerical calculations. These calculations were performed describing the light pulse shape by means of a new, quite general analytical method based on the geometrical optics concepts of virtual light paths and images. The associated electric pulses produced by the PMTs coupled to the scintillators are then discussed with particular emphasis on their dependence on the distance between light source and photocathode. (orig.).

  8. Non azeotrope mixing refrigerating fluids condensation outside of an horizontal tubes stack; Condensation de melanges non azeotropes de fluides frigorigenes a l'exterieur d'un faisceau de tubes horizontaux

    Energy Technology Data Exchange (ETDEWEB)

    Signe, J.Ch.

    1999-04-16

    The development of non-azeotrope mixing, as regular refrigerating fluids substitute, calls in question the experience for the design of refrigerating and cooling machinery. Studies to better understand these fluids behaviour are necessary. The aim of this thesis is the knowledge enlargement on the pure fluids and non azeotrope mixing condensation, outside of a tubes stack, and to simulate the heat transfers. The tubes stack is a condenser, type TEMA X often used in refrigerating machinery. The binary mixing HFC 134a-HFC23, allows a large sliding scale. (A.L.B.)

  9. REACH. Refrigeration Units.

    Science.gov (United States)

    Snow, Rufus; And Others

    As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of refrigeration. The instructional units focus on refrigeration fundamentals, tubing and pipe, refrigerants, troubleshooting, window air conditioning, and…

  10. Effect of Fin Geometry on Condensation Heat Transfer of Refrigerant R134a on Enhanced Finned Tubes

    Science.gov (United States)

    Takahashi, Hiroyuki; Saeki, Chikara; Koyama, Shigeru

    This paper presents the experimental results on the outside condensation heat tral1sfer coefficient of horizontal enhanced filmed tubes. Three different fin geometry types of three-dimensional enhanced finned tubes were tested. A low-fin-tube (LFT) 19 fin-per-inch (fpi) was also tested for reference. Experimental refrigerant used was R134a. The heat tral1sfer coefficient test was carried out at a condensing temperature of 40°C, at a cooling water velocity of 1.5 m/s, and the heat flux of 10 to 110 kW/m2K. The outside condensation heat transfer coefficient of all three dimensional enhanced finned tubes were approximately 1.9 times higher than that of LFTl9fpi at high heat flux range. In low heat flux range, the enhanced finned tube of small circumferential segmentation pitches at the fin tip was shown the highest outside heat transfer coefficient for all tubes tested.

  11. Design, development and testing twin pulse tube cryocooler

    Science.gov (United States)

    Gour, Abhay Singh; Sagar, Pankaj; Karunanithi, R.

    2017-09-01

    The design and development of Twin Pulse Tube Cryocooler (TPTC) is presented. Both the coolers are driven by a single Linear Moving Magnet Synchronous Motor (LMMSM) with piston heads at both ends of the mover shaft. Magnetostatic analysis for flux line distribution was carried-out during design and development of LMMSM based pressure wave generator. Based on the performance of PWG, design of TPTC was carried out using Sage and Computational Fluid Dynamics (CFD) analysis. Detailed design, fabrication and testing of LMMSM, TPTC and their integration tests are presented in this paper.

  12. Characteristics of two-phase flow pattern transitions and pressure drop of five refrigerants in horizontal circular small tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pamitran, A.S. [Department of Mechanical Engineering, University of Indonesia, Kampus Baru UI, Depok 16424 (Indonesia); Choi, Kwang-Il [Graduate School, Chonnam National University, San 96-1, Dunduk-Dong, Yeosu, Chonnam 550-749 (Korea); Oh, Jong-Taek [Department of Refrigeration and Air Conditioning Engineering, Chonnam National University, San 96-1, Dunduk-Dong, Yeosu, Chonnam 550-749 (Korea); Hrnjak, Pega [Department of Mechanical Science and Engineering, ACRC, University of Illinois at Urbana-Champaign, 1206 West Green Street, Urbana, IL 61801 (United States)

    2010-05-15

    An experimental investigation on the characteristics of two-phase flow pattern transitions and pressure drop of R-22, R-134a, R-410A, R-290 and R-744 in horizontal small stainless steel tubes of 0.5, 1.5 and 3.0 mm inner diameters is presented. Experimental data were obtained over a heat flux range of 5-40 kW/m{sup 2}, mass flux range of 50-600 kg/(m{sup 2} s), saturation temperature range of 0-15 C, and quality up to 1.0. Experimental data were evaluated with Wang et al. and Wojtan et al. [Wang, C.C., Chiang, C.S., Lu, D.C., 1997. Visual observation of two-phase flow pattern of R-22, R-134a, and R-407C in a 6.5-mm smooth tube. Exp. Therm. Fluid Sci. 15, 395-405; Wojtan, L., Ursenbacher, T., Thome, J.R., 2005. Investigation of flow boiling in horizontal tubes: part I - a new diabatic two-phase flow pattern map. Int. J. Heat Mass Transfer 48, 2955-2969.] flow pattern maps. The effects of mass flux, heat flux, saturation temperature and inner tube diameter on the pressure drop of the working refrigerants are reported. The experimental pressure drop was compared with the predictions from some existing correlations. A new two-phase pressure drop model that is based on a superposition model for two-phase flow boiling of refrigerants in small tubes is presented. (author)

  13. Advantages of high-frequency Pulse-tube technology and its applications in infrared sensing

    Science.gov (United States)

    Arts, R.; Willems, D.; Mullié, J.; Benschop, T.

    2016-05-01

    The low-frequency pulse-tube cryocooler has been a workhorse for large heat lift applications. However, the highfrequency pulse tube has to date not seen the widespread use in tactical infrared applications that Stirling cryocoolers have had, despite significant advantages in terms of exported vibrations and lifetime. Thales Cryogenics has produced large series of high-frequency pulse-tube cryocoolers for non-infrared applications since 2005. However, the use of Thales pulse-tube cryocoolers for infrared sensing has to date largely been limited to high-end space applications. In this paper, the performances of existing available off-the-shelf pulse-tube cryocoolers are examined versus typical tactical infrared requirements. A comparison is made on efficiency, power density, reliability, and cost. An outlook is given on future developments that could bring the pulse-tube into the mainstream for tactical infrared applications.

  14. Pulsed response of a traveling-wave tube

    Science.gov (United States)

    May, Brian D.

    1991-01-01

    The consequence of frequency-domain multiple access (FDMA) channelization in a satellite communications system is that the ground- and space-based components are often required to operate at reduced output power to prevent the generation of distortions. However, the components of a time-division multiple access (TDMA) satellite system, such as a traveling-wave tube (TWT), can operate at the highest output power because the channelization technique is relatively insensitive to the distortions resulting from saturated operation. A Hughes 30-GHz TWT was tested to determine the suitability of such a device in a TDMA system. Testing was focused on the ability of the TWT to rise up to full power at the leading edge of TDMA bursts, which were simulated by a pulse train. A Wavetek model 8502A peak power meter was used to display and measure the pulsed signal waveform. Measurements of the TWT output signal rise time indicate that the TWT lengthened the rise time by 10 to 20 nsec. Imposing a modulator turn-on time that precedes the data burst by the TWT rise time is a logical approach to coordinating the traveling-wave tube amplifier and modulator specifications.

  15. A vibration free cryostat using pulse tube cryocooler

    Science.gov (United States)

    Wang, Chao; Hartnett, John G.

    2010-05-01

    This paper introduces a new vibration free cryostat cooled by liquid helium and a 4 K pulse tube cryocooler. The cryogenic device mounts on the sample cooling station which is cooled by liquid helium. The boil off helium is recondensed by the pulse tube cryocooler, thus the cryostat maintains zero boil off. There is no mechanical contact between the cryogenic part of the cryocooler and the sample cooling station. A bellows is used to isolate the vibration which could transfer from the cryocooler flange to the cryostat flange at the room temperature. Any vibrations generated by the operation of the cryocooler are almost entirely isolated from the cryogenic device. The cryostat provides a cooling capacity of 0.65 W at 4.21 K on the sample cooling station while maintaining a vapor pressure of 102 kPa. The sample cooling station has a very stable temperature with oscillations of less than ±3 mK during all the operations. A cryogenic microwave oscillator has been successfully cooled and operated with the cryostat.

  16. Effect of Fin Geometry on Condensation of Zeotropic Refrigerant Mixture R407C in a Staggered Bundle of Horizontal Finned Tubes

    Science.gov (United States)

    Honda, Hiroshi; Takata, Nobuo; Takamatsu, Hiroshi; Kim, Jeongsik; Usami, Keiichiro

    Row-by-row heat transfer data were obtained during condensation of downward-flowing refrigerant mixture R407C in a staggered bundle of horizontal finned tubes. Two kinds of conventional low-fin tubes with flat-sided annular fins and three kinds of three-dimensional fin tubes were tested. The refrigerant mass velocity ranged from 4 to 23 kg/m2s, and the condensation temperature difference from 1.5 to 12 K. At a low to medium film Reynolds number(2000), on the other hand, the highest performance was obtained by one of the low-fin tubes. For all tubes tested, the heat transfer coefficient decreased with decreasing mass velocity. On the basis of previous results for R134a, consideration was given to the characteristics of vapor phase mass transfer of R407C.

  17. A two-stage Stirling-type pulse tube cryocooler with a cold inertance tube

    Science.gov (United States)

    Gan, Z. H.; Fan, B. Y.; Wu, Y. Z.; Qiu, L. M.; Zhang, X. J.; Chen, G. B.

    2010-06-01

    A thermally coupled two-stage Stirling-type pulse tube cryocooler (PTC) with inertance tubes as phase shifters has been designed, manufactured and tested. In order to obtain a larger phase shift at the low acoustic power of about 2.0 W, a cold inertance tube as well as a cold reservoir for the second stage, precooled by the cold end of the first stage, was introduced into the system. The transmission line model was used to calculate the phase shift produced by the cold inertance tube. Effect of regenerator material, geometry and charging pressure on the performance of the second stage of the two-stage PTC was investigated based on the well known regenerator model REGEN. Experimental results of the two-stage PTC were carried out with an emphasis on the performance of the second stage. A lowest cooling temperature of 23.7 K and 0.50 W at 33.9 K were obtained with an input electric power of 150.0 W and an operating frequency of 40 Hz.

  18. High efficiency linear compressor driven pulse tube cryocooler operating in liquid nitrogen temperature

    Institute of Scientific and Technical Information of China (English)

    HU JianYing; WANG XiaoTao; DAI Wei; LUO ErCang; HUANG Yu

    2009-01-01

    The inertance tube is one of the key components of a pulse tube cryocooler. It has great influence not only on the efficiency of the pulse tube cryocooler, but also on the efficiency of the linear compressor. Meanwhile, it is very difficult to predict the impedance of an inertance tube because of the turbulent flow. In this paper, using a quasi-turbulent model, the inertance tube is optimized to match a linear compressor driven pulse tube cryocooler. Experimental results show that this model can predict the impedance quite well. With 127 W input electric power, the pulse tube cryocooler obtains 9.4 W cooling power at a temperature of 77 K. The relative Carnot efficiency of the whole system reaches 19.8%.

  19. A novel coupling configuration for thermoacoustically-driven pulse tube coolers: Acoustic amplifier

    Institute of Scientific and Technical Information of China (English)

    DAI Wei; LUO Ercang; HU Jianying; CHEN Yanyan

    2005-01-01

    Thermoacoustically-driven pulse tube cooler can provide cryogenic cooling power with no moving components. Up to now, pulse tube cooler is directly coupled with the thermoacoustic engine and obtainable pressure ratio for the pulse tube cooler is limited by the capability of the thermoacoustic engine. The authors propose here the concept of acoustic amplifier, which is actually a long tube connecting the engine with the pulse tube cooler. Theoretical calculation shows that suitable length and diameter of the tube can lead to a pressure wave amplification effect which means that pressure wave amplitude coming from the thermoacoustic engine can be much amplified to drive the pulse tube cooler. Based on this, a 2.8 m long copper tube with 8 mm inner diameter is used as the acoustic amplifier in experiments. The experimental results show that due to the amplification effect, pressure wave amplitude at the inlet of the pulse tube cooler is over 2.5 times of that at the engine outlet. Typically, with 1.67 kW heating power, the pressure ratio provided by the engine is 1.11 while at the inlet of the pulse tube cooler the pressure ratio is 1.32, which leads to a lowest no-load temperature of 65.7 K.

  20. Forced Convective Condensation of Nonazeotropic Refrigerant Mixtures in Horizontal Annulus with Petal Shaped Fin Tubes

    Institute of Scientific and Technical Information of China (English)

    WangShiping; ZhouXinqiu; 等

    1995-01-01

    In this paper,condensation performance in horizontal annulus was compared with a smooth tube,one Saw-Tooth Finned tube(STF tube),four Petal Shaped Fin tubes(PF tubes),using R113,R11 and their mixtures(vapor molar fractions of R11 at the test section inlet were 0.384,0.588and 0.809) as working fluid.The mass flux at the test section ranged from 15-220/m2s。Camera and video camera were used to shoot the flow pattern and condensation phenomena.The condensation transfer coefficient(hc) of mixtures were considerably lower than those of pure fluid,and did not change linearly with composition.The maximum degradation of measured hc from the ideal value were 23% for the smooth tube,65%for STF tube,67% for PF tubes,which occurred in the composition range of 0.4-0.6 vapor molar fraction of R11.For the condensation of mixture,R11 molar fraction from 38%to 81%,the PF tubes had the highest value of hc.which were 10-25% higher than those of STF tubes,and 480-580% higher than that of smooth tube,because the petal shaped fins of PF tubes could promote strong turbulence in the two phase flow,and reduce the mass transfer resistance.

  1. EHD enhancement of pool and in-tube boiling of alternate refrigerants. Final report, 15 January 1993--15 June 1993

    Energy Technology Data Exchange (ETDEWEB)

    Ohadi, M.M.; Dessiatoun, S.; Singh, A.; Fanni, M.A.

    1993-08-01

    The Electrohydrodynamic (EHD) is an active heat transfer augmentation technique which utilizes the effect of secondary motions generated through the application of an electrostatic potential to a dielectric fluid. Net result is better momentum and heat transfer between the fluid and the heat transfer wall through destabilization of the thermal boundary layer and better mixing of the fluid adjacent to the heat transfer surface. EHD enhancement of refrigerant/refrigerant oil mixtures heat transfer using the Electrohydrodynamic (EHD) technique is the subject of a three-year experimental investigation in a project funded by the US Department of Energy, effective June 1, 1993. For the interim period between November 1992 and June 1993 when the DOE funds became available, the Air-Conditioning and Refrigeration Technology Institute (ARTI) provided partial funding for our EHD research program with the aim of accomplishing three major tasks: (1) conduct a comprehensive search of the literature on EHD-enhanced, in-tube and external boiling heat transfer enhancement of alternate refrigerants; (2) Design, fabricate, and instrument an in-tube, EHD-enhanced boiling/condensation test rig and perform preliminary testing of the setup; (3) conduct experiments and document new findings on EHD-enhanced external boiling of alternate refrigerants/refrigerant mixtures in an existing pool boiling test rig apparatus. Description of Tasks performed are described and results are discussed.

  2. Measurement of Anisotropic Hydrodynamic Parameters of Pulse Tube or Stirling Cryocooler Regenerators

    Science.gov (United States)

    Cha, J. S.; Ghiaasiaan, S. M.; Desai, P. V.

    2006-04-01

    Pulse tube refrigeration (PTR) systems are often modeled as one-dimensional flow fields. However, recent computational fluid dynamics (CFD) — based investigations have shown that multi-dimensional flow effects can be significant in the regenerator of a PTR, especially when the aspect ratio of the regenerator is small. Anisotropic hydrodynamic parameters of regenerators are therefore needed for the realistic simulation of their multi-dimensional flow phenomena. In this paper we report on measurements of the lateral or radial permeability and Forchheimer's inertial coefficient of a widely used PTR regenerator filler. Using helium as the working fluid, steady-state pressure drops were measured over a wide range of flow rates in annular test sections that contained regenerator fillers. The aforementioned hydrodynamic parameters were then obtained by comparing the data with the results of CFD calculations that simulated the test sections and their vicinity. CFD simulations of the experiments were performed iteratively, whereby permeability and Forchheimer coefficient that brought about agreement between data and simulation results were calculated.

  3. Development of high capacity Stirling type pulse tube cryocooler

    Energy Technology Data Exchange (ETDEWEB)

    Imura, J. [College of Science and Technology, Nihon University, 7-24-1, Narashinodai, Funabashi-shi, Chiba 274-8501 (Japan)], E-mail: junnosuke_imura@yahoo.co.jp; Shinoki, S.; Sato, T.; Iwata, N.; Yamamoto, H.; Yasohama, K. [College of Science and Technology, Nihon University, 7-24-1, Narashinodai, Funabashi-shi, Chiba 274-8501 (Japan); Ohashi, Y.; Nomachi, H.; Okumura, N. [Aisin Seiki Co., Ltd., 2-1, Asahi-machi, Kariya, Aichi 448-8650 (Japan); Nagaya, S.; Tamada, T.; Hirano, N. [Chubu Electric Power Co., Inc., 1, Toshin-cho, Higashi-ku, Nagoya-shi, Aichi 261-8680 (Japan)

    2007-10-01

    We have been developing a Stirling type pulse tube cryocooler, aiming for a cooling capacity of 200 W at 80 K for a superconducting magnetic energy storage system. In this work, we adopted stainless steel meshes for the regenerator of the cryocooler, and studied the influences of the mesh number on the cooling capacity. The prepared mesh numbers were 150, 200, 250, 350 and 400. Using 250 mesh, and at a frequency of 45 Hz and power consumption of 3.1 kW, the achievable lowest temperature and cooling capacity at 80 K was 46.2 K and 123 W, respectively. Furthermore, in order to optimize the performance, some regenerators were made by stacking several kinds of meshes with different stacking orders. Using these regenerators, we have obtained a high cooling capacity of 169 W at 80 K with power consumption of 4 kW.

  4. Development of high capacity Stirling type pulse tube cryocooler

    Science.gov (United States)

    Imura, J.; Shinoki, S.; Sato, T.; Iwata, N.; Yamamoto, H.; Yasohama, K.; Ohashi, Y.; Nomachi, H.; Okumura, N.; Nagaya, S.; Tamada, T.; Hirano, N.

    2007-10-01

    We have been developing a Stirling type pulse tube cryocooler, aiming for a cooling capacity of 200 W at 80 K for a superconducting magnetic energy storage system. In this work, we adopted stainless steel meshes for the regenerator of the cryocooler, and studied the influences of the mesh number on the cooling capacity. The prepared mesh numbers were #150, 200, 250, 350 and 400. Using #250 mesh, and at a frequency of 45 Hz and power consumption of 3.1 kW, the achievable lowest temperature and cooling capacity at 80 K was 46.2 K and 123 W, respectively. Furthermore, in order to optimize the performance, some regenerators were made by stacking several kinds of meshes with different stacking orders. Using these regenerators, we have obtained a high cooling capacity of 169 W at 80 K with power consumption of 4 kW.

  5. A helium liquefier using three 4 k pulse tube cryocoolers

    Science.gov (United States)

    Wang, Chao; Oviedo, Abner

    2012-06-01

    We have developed a helium liquefier which can be used for recondensing/reliquefying helium vapor in a helium cryostat or liquefying helium gas in a storage dewar. The helium liquefier employs three 4 K pulse tube cryocoolers, Cryomech model PT415. Each PT415 has remote motor/rotary valve assembly to minimize vibration, providing ≥ 1.5W at 4.2K. The liquefier can liquefy room temperature helium gas with a liquefaction rate of 62 Liter/day. When installing it in the cryostat, it can recondense and reliquefy helium vapor with a rate of 78 L/day. The liquefier will be installed in a gravitational wave detector in Brazil to recondense/reliquefy the helium boil off from the cryostat.

  6. Pulse Tube Interference in Cryogenic Sensor Resonant Circuits - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Tyler [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-27

    Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise, it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.

  7. Single pulse shock tube study of allyl radical recombination.

    Science.gov (United States)

    Fridlyand, Aleksandr; Lynch, Patrick T; Tranter, Robert S; Brezinsky, Kenneth

    2013-06-13

    The recombination and disproportionation of allyl radicals has been studied in a single pulse shock tube with gas chromatographic measurements at 1-10 bar, 650-1300 K, and 1.4-2 ms reaction times. 1,5-Hexadiene and allyl iodide were used as precursors. Simulation of the results using derived rate expressions from a complementary diaphragmless shock tube/laser schlieren densitometry study provided excellent agreement with precursor consumption and formation of all major stable intermediates. No significant pressure dependence was observed at the present conditions. It was found that under the conditions of these experiments, reactions of allyl radicals in the cooling wave had to be accounted for to accurately simulate the experimental results, and this unusual situation is discussed. In the allyl iodide experiments, higher amounts of allene, propene, and benzene were found at lower temperatures than expected. Possible mechanisms are discussed and suggest that iodine containing species are responsible for the low temperature formation of allene, propene, and benzene.

  8. Thermodynamic analysis and experimental verfication on a novel looped pulse tube cryocooler

    Science.gov (United States)

    Wang, Xiaotao; Luo, Ercang; Dai, Wei; Hu, Jianying; Zhou, Yuan

    2012-06-01

    Compared with the Stirling cryocooler, the pulse tube cryocooler has obvious advantage in reliability. The reservoir is usually needed to help the inertance tube to obtain larger phase shifting ability, which makes the pulse tube cryocooler not to be as compact as the Stirling cryocoolers. To improve compactness, a looped pulse tube cryocooler without the reservoir was proposed in the paper. The inertance-tube is directly connected to the backside of a linear compressor and the reservoir is removed. To compare its cooling performance with that of the inertance-tube pulse tube cryocooler with a reservoir, the theoretical model including a linear compressor, main hot-end exchanger, regenerator, cold-end exchanger, pulse tube, and secondary hot-end exchanger are described for the both cryocoolers. The simulation results show that the looped cryocooler can achieve a similar or even better cooling performance, comparing with the traditional inertance-tube cryocooler. In the experiment, the performances of both cryocoolers driven by a same linear compressor were extensively tested. A lowest cold-head temperature of 40 K is acquired and the maximum cooling power reached 9.4 W at 77 K for the novel looped pulse tube cooler, corresponding to about 15% relative Carnot efficiency

  9. Experimental study on condensation of refrigerant-oil mixtures. Part 3; R-12 and R-22 on the external surface of single and multiple horizontal finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.C.Y.; Lin, S.; Fazio, P.; Jiang, Z. (Concordia Univ., Montreal, Quebec (CA))

    1989-01-01

    Presented are the test results of R-12 and R-22 on the external surface of horizontal finned tubes. The oil used in this study is alkylbenzene-based. Both pure refrigerant vapor tests and vapor-oil mixture tests were conducted at two different condensing temperatures-32.2{degrees} and 40.5{degrees}C (90{degrees} and 105{degrees}F), respectively. It was found that the presence of oil in R-12 and R-22 vapor with any mass radio lowers the condensing coefficient. However, the reduction of the condensing coefficient is not proportional to the percent of oil in the refrigerant vapors for the finned tubes. As for the pressure drop across the condenser, the effect of oil in the refrigerant vapors is not noticeable.

  10. Dissipation of Alfven wave pulses propagating along dipole magnetic tubes with reflections at the ionosphere

    NARCIS (Netherlands)

    Erkaev, NV; Shaidurov, VA; Semenov, VS; Biernat, HK; Heidorn, D; Lakhina, GS

    2006-01-01

    A ratio of the maximal and minimal cross sections of the magnetic tube (contraction ratio) is a crucial parameter which affects very strongly on reflections of MHD wave pulses propagating along a narrowing magnetic flux tube. In cases of large contraction ratios of magnetospheric magnetic tubes, the

  11. Measurement of Work Generation and Improvement in Performance of a Pulse Tube Engine

    Science.gov (United States)

    Hamaguchi, Kazuhiro; Futagi, Hiroaki; Yazaki, Taichi; Hiratsuka, Yoshikatsu

    Apart from double acting type engines, Stirling engines have either 2 pistons in 2 cylinders or 2 pistons in a single cylinder. Typically, the heater, regenerator and cooler are installed between the 2 pistons. The pulse tube engine, on the other hand, consists of a single piston in a single cylinder, a pulse tube, a heater, a regenerator, a cooler and a second cooler. For this paper, a simple prototype engine that uses air at normal atmospheric pressure as the working gas was fabricated. The oscillating velocity of the working gas in the pulse tube was measured using LDV, and the work flow emitting out of the pulse tube was observed. In addition, the effect of inserting heat storage material in the pulse tube on shaft power and indicated power was examined experimentally. A dramatic increase in the shaft power was achieved.

  12. Eddy-current inspection of ferromagnetic tubing using pulsed magnetic saturation

    Energy Technology Data Exchange (ETDEWEB)

    Dodd, C V; Deeds, W E

    1986-07-01

    A pulsed eddy-current system has been designed and developed for nondestructive evaluation of 2.25Cr-1Mo steam generator tubing from the bore side. Since the tubing is ferromagnetic, a large current pulse is sent through a driver coil to produce magnetic saturation all the way through the tube wall. A pickup coil produces an output pulse that is dependent upon the tube properties as well as the driving pulse. The output pulse heights at selected times are used as data that are computer-correlated with calibration data taken from machined standards. Performance data, circuit diagrams, and computer programs are given for the system, which has been demonstrated to detect small flaws located near the outside of a thick ferromagnetic tube.

  13. Properties of new refrigerants and predictions for condensation heat transfer enhancement with low-finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Stegou-Sagia, A. [National Technical University of Athens (Greece). Dept. of Mechanical Engineering

    1996-12-01

    The present article provides a review of thermophysical properties research of environmentally acceptable refrigerants. In recent years, it has become evident that common CFC type refrigerants can cause serious environmental damage when released into the atmosphere. The group of HFCs (HFC-32, HFC-125, HFC-134a, HFC-152a) with no chlorine atom in their chemical formulae and quite short atmospheric lifetime may be promising alternatives to CFCs. A compilation of properties is given which may be used to obtain arithmetic expressions for the vapour pressure, saturated liquid density, viscosity, latent heat of vaporization, saturated liquid thermal conductivity, and surface tension of these hydrofluorocarbons. For easily available comparisons, the results are presented in diagrams illustrating the dependence of thermophysical data on temperature at the saturated state. (author)

  14. Numerical studies on the effects of hot end temperature on a single-stage multi-bypass type pulse tube cryocooler

    Science.gov (United States)

    Liu, S. X.; Chen, L. B.; Zhou, Y.; Wang, J. J.

    2015-12-01

    The performance of pulse tube cryocooler is affected by the temperature of hot end, which is mainly influenced by the temperature of environment. Effects on a single-stage multibypass type pulse tube cryocooler are investigated by means of numerical simulation. For different opening of multi-bypass orifices, the refrigeration performances are studied when hot end temperature changed in a certain range, and some numerical results are provided and analysed. Together with the temperature at cold head and multi-bypass position, the mass flow rate through the multi-bypass orifice is affected significantly by the temperature of hot end, and the optimum opening of multi-bypass orifice decreases with hot end temperature increasing from 240 K to 320 K. Therefore, to select an optimal opening of bypass orifice according to the temperature of operating environment is necessary.

  15. A dynamic model of a shell-and-tube condenser operating in a vapour compression refrigeration plant

    Energy Technology Data Exchange (ETDEWEB)

    Llopis, R.; Cabello, R. [Dept. of Mechanical Engineering and Construction, Campus de Riu Sec, Jaume I Univ., E-12071 Castellon (Spain); Torrella, E. [Dept. of Applied Thermodynamics, Camino de Vera 14, Polytechnic Univ. of Valencia, E-46022 Valencia (Spain)

    2008-07-15

    This work presents a mathematical model of a shell-and-tube condenser based on mass continuity, energy conservation and heat transfer physical fundamentals, whose methodology can be easily adapted for modelling any type of condenser. The model is formulated as a combination of control volumes that represents all the refrigerant states in the condenser and the liquid receiver function, which is carried out by the condenser of the experimental plant. Model validation is performed by using steady-state data and transient tests from an experimental vapour compression plant; the prediction error of the model is lower than 5% and a good representation of the dynamic performance of the condenser is achieved. A theoretical comparison involving the importance of the dynamic responses of the evaporator and the condenser at the plant is also presented. (author)

  16. Enhancement of heat transfer in condensation of refrigerant vapor on horizontal finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, O.P.; Khizhnyakov, S.V. (Northwestern Polytechnic Inst. (SU))

    1991-01-01

    This paper reports on the technique for predicting the heat transfer coefficients in film condensation of Freons on horizontal tubes with different fin geometries that has been improved. The suggested technique allows for the spatial orientation of the different parts of the heat transfer area, the capillary contraction of condensate, and its holdup on the bottom zone of the horizontal tube.

  17. Condensation Heat-Transfer Measurements of Refrigerants on Externally Enhanced Tubes.

    Science.gov (United States)

    1987-06-01

    fins (m 2) as Coefficient used in eqn. 5.6 At Area of smooth tube (same as Ao) (m 2) cb Fraction of tube surface flooded C, Sieder -Tate-type...modified Wilson plot method was used to process all data. The Sieder -Tate-type equation (eqn. 4.6)- was used for the inside heat-transfer coefficient. A...Flux 2.535E+04 (W/m𔃼) Tube-metal thermal conduc. 385.0 (W/m.K) Sieder -Tate constant 0.0280 UNCERTAINTY ANALYSIS: VARIABLE PERCENT UNCERTAINTY Mass

  18. Investigation on phase shifting for a 4 K Stirling pulse tube cryocooler with He-3 as working fluid

    Science.gov (United States)

    Qiu, L. M.; Han, L.; Zhi, X. Q.; Dietrich, M.; Gan, Z. H.; Thummes, G.

    2015-07-01

    He-3 is generally recognized for its ability to provide more excellent thermophysical performance than He-4, especially in the 4 K temperature range. However, this was not always the case in our preliminary experiments on a three-stage Stirling-type pulse tube cryocooler (SPTC). Our ongoing studies, as reported in this paper, demonstrate that the different working fluids also affect the performance through their phase shifting capability. This feature has been passed over in large part by researchers considering refrigerant substitution. Unlike previous theoretical analyses that focus primarily on regenerator losses, this report investigates the effects of the working fluid on the phase angle at the cold end in order to quantitatively reveal the relationship between the lowest attainable temperature and the cooling capacity. The analysis agrees well with our experimental results on a three-stage SPTC. While running with the operating parameters optimized for He-3, the lowest temperature of the SPTC decreased from 5.4 K down to 4.03 K. This is the lowest refrigeration temperature ever achieved with a three-stage SPTC.

  19. High-T{sub c} DC SQUID system cooled by pulse-tube cooler

    Energy Technology Data Exchange (ETDEWEB)

    He, D.F.; Nakamura, M.; Yoshizawa, M

    2003-10-15

    We developed a high-T{sub c} DC SQUID system cooled by pulse-tube cooler. To avoid the influence of the wire resistance between SQUID and preamplifier, and to reduce the influence of the temperature fluctuation of pulse-tube cooler, DC coupling between SQUID chip and preamplifier was used and the flux locked loop worked in modulation mode. We also developed a temperature controller, using the DC SQUID as temperature sensor, to control and stabilize the operating temperature of the pulse-tube cooler. With the temperature controller, the DC SQUID system could remain locked for over 8 h.

  20. A critical review of liquid helium temperature high frequency pulse tube cryocoolers for space applications

    Science.gov (United States)

    Wang, B.; Gan, Z. H.

    2013-08-01

    The importance of liquid helium temperature cooling technology in the aerospace field is discussed, and the results indicate that improving the efficiency of liquid helium cooling technologies, especially the liquid helium high frequency pulse tube cryocoolers, is the principal difficulty to be solved. The state of the art and recent developments of liquid helium high frequency pulse tube cryocoolers are summarized. The main scientific challenges for high frequency pulse tube cryocoolers to efficiently reach liquid helium temperatures are outlined, and the research progress addressing those challenges are reviewed. Additionally some possible solutions to the challenges are pointed out and discussed.

  1. Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

    Science.gov (United States)

    Johnson, Dean L.; Rodriguez, Jose I.; Carroll, Brian A.; Bustamante, John G.; Kirkconnell, Carl S.; Luong, Thomas T.; Murphy, J. B.; Haley, Michael F.

    2014-01-01

    The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

  2. Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Dean L.; Rodriguez, Jose I.; Carroll, Brian A. [The Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Bustamante, John G. [Georgia Institute of Technology, Atlanta, GA 30332 (United States); Kirkconnell, Carl S.; Luong, Thomas T.; Murphy, J. B.; Haley, Michael F. [Iris Technology, Irvine, CA 92616 (United States)

    2014-01-29

    The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

  3. Study on a cascade pulse tube cooler with energy recovery: new method for approaching Carnot

    Science.gov (United States)

    Wang, L. Y.; Wu, M.; Zhu, J. K.; Jin, Z. Y.; Sun, X.; Gan, Z. H.

    2015-12-01

    A pulse tube cryocooler (PTC) can not achieve Carnot efficiency because the expansion work must be dissipated at the warm end of the pulse tube. How to recover this amount of dissipated work is a key for improving the PTC efficiency. A cascade PTC consists of PTCs those are staged by transmission tubes in between, these can be a two-stage or even more stages, each stage is driven by the recovered work from the last stage by a well-designed long transmission tube. It is shown that the more stages it has, the closer the efficiency will approach the Carnot efficiency. A two-stage cascade pulse tube cooler consisted of a primary and a secondary stage working at 233 K is designed, fabricated and tested in our lab. Experimental results show that the efficiency is improved by 33% compared with the single stage PTC.

  4. a Thermoacoustically-Driven Pulse Tube Cryocryocooler Operating around 300HZ

    Science.gov (United States)

    Yu, G. Y.; Zhu, S. L.; Dai, W.; Luo, E. C.

    2008-03-01

    High frequency operation of the thermoacoustic cryocooler system, i.e. pulse tube cryocooler driven by thermoacoustic engine, leads to reduced size, which is quite attractive to small-scale cryogenic applications. In this work, a no-load coldhead temperature of 77.8 K is achieved on a 292 Hz pulse tube cryocooler driven by a standing-wave thermoacoustic engine with 3.92 MPa helium gas and 1750 W heat input. To improve thermal efficiency, a high frequency thermoacoustic-Stirling heat engine is also built to drive the same pulse tube cryocooler, and a no-load temperature of 109 K was obtained with 4.38 MPa helium gas, 292 Hz working frequency and 400W heating power. Ideas such as tapered resonators, acoustic amplifier tubes and simple thin tubes without reservoir are used to effectively suppress harmonic modes, amplify the acoustic pressure wave available to the pulse tube cryocooler and provide desired acoustic impedance for the pulse tube cryocooler, respectively. Comparison of systems with different thermoacoustic engines is made. Numerical simulations based on the linear thermoacoustic theory have also been done for comparison with experimental results, which shows reasonable agreement.

  5. Overview of RICOR tactical cryogenic refrigerators for space missions

    Science.gov (United States)

    Riabzev, Sergey; Filis, Avishai; Livni, Dorit; Regev, Itai; Segal, Victor; Gover, Dan

    2016-05-01

    Cryogenic refrigerators represent a significant enabling technology for Earth and Space science enterprises. Many of the space instruments require cryogenic refrigeration to enable the use of advanced detectors to explore a wide range of phenomena from space. RICOR refrigerators involved in various space missions are overviewed in this paper, starting in 1994 with "Clementine" Moon mission, till the latest ExoMars mission launched in 2016. RICOR tactical rotary refrigerators have been incorporated in many space instruments, after passing qualification, life time, thermal management testing and flight acceptance. The tactical to space customization framework includes an extensive characterization and qualification test program to validate reliability, the design of thermal interfacing with a detector, vibration export control, efficient heat dissipation in a vacuum environment, robustness, mounting design, compliance with outgassing requirements and strict performance screening. Current RICOR development is focused on dedicated ultra-long-life, highly reliable, space cryogenic refrigerator based on a Pulse Tube design

  6. Experimental investigation on two pulse tube cryocoolers driven by single linear opposed compressor%单直线压缩机驱动双脉管冷指的实验研究

    Institute of Scientific and Technical Information of China (English)

    曹永刚; 陈曦; 吴亦农; 杨开响; 张安阔; 熊超

    2013-01-01

    为了在不同位置获得不同的制冷性能,设计了一台线性对置压缩机驱动两台同轴型脉管冷指的实验方案并搭建了试验台.通过实验研究两台脉管制冷机耦合的制冷性能.实验结果显示:两台设计相同的脉管冷指性能不同,经过耦合后制冷性能差异更大,可同时达到1.79 W@60 K和1.384 W@60 K制冷量.%In order to achieve refrigeration at different positions, two coaxial pulse tube cryocoolers operated by single linear opposed compressor were designed to investigate. The test bench was conducted. The performances of two matching pulse tube cryocoolers were investigated by the test bench. Experimental results show that the characters of two pulse tube cryocoolers designed identically were different. After coupling, the differences on the performances between the two pulse tube cryocoolers were more obvious. The two pulse tube cryocoolers could achieve cooling capacities of 1.79 W at 60 K and 1.384 W at 60 K simultaneously.

  7. Study on a pulse tube cryocooler using gas mixture as its working fluid

    Science.gov (United States)

    Gao, C. M.; He, Y. L.; Chen, Z. Q.

    2000-01-01

    In order to improve the performance of a one-stage pulse tube cryocooler, gas mixtures are used for comparison, which have been used in other cryocoolers. A mixture of hydrogen and helium was investigated in this study. When the structure of the pulse tube is the same as mentioned in [C. Wang, P.Y. Wu, Zh.Q. Chen, Numerical modeling of an orifice pulse tube cryocooler, Cryogenics 32 (1992) 785] and the working conditions are: frequency 15 Hz, average pressure 1.1 MPa, hot end temperature 300 K and cold end temperature 80 K, it has been found that there are optimal molar percentage for the maximal cooling power and the maximal-coefficient of performance (COP) of this cryocooler.

  8. Cool sound: the future of refrigeration? Thermodynamic and heat transfer issues in thermoacoustic refrigeration

    Science.gov (United States)

    Herman, C.; Travnicek, Z.

    2006-04-01

    During the past two decades the thermoacoustic refrigeration and prime mover cycles gained importance in a variety of refrigeration applications. Acoustic work, sound, can be used to generate temperature differences that allow the transport of heat from a low temperature reservoir to an ambient at higher temperature, thus forming a thermoacoustic refrigeration system. The thermoacoustic energy pumping cycle can also be reversed: temperature difference imposed along the stack plates can lead to sound generation. In this situation the thermoacoustic system operates as a prime mover. Sound generated by means of this thermoacoustic energy conversion process can be utilized to drive different types of refrigeration devices that require oscillatory flow for their operation, such as thermoacoustic refrigerators, pulse tubes and Stirling engines. In order for a thermoacoustic refrigeration or prime mover system as well as a thermoacoustic prime mover driving a non-thermoacoustic refrigeration system to be competitive on the current market, it has to be optimized in order to improve its overall performance. Optimization can involve improving the performance of the entire system as well as its components. The paper addresses some of the thermodynamic and heat transfer issues relevant in improving the performance of the thermoacoustic system, such as optimization for maximum COP, maximum cooling load and the role of the heat exchangers. Results obtained using the two optimization criteria are contrasted in the paper to illustrate the complexity of the optimization process.

  9. Development of a linear compressor for two-stage pulse tube cryocoolers

    Institute of Scientific and Technical Information of China (English)

    Peng-da YAN; Wei-li GAO; Guo-bang CHEN

    2009-01-01

    A valveless linear compressor was built up to drive a self-made two-stage pulse tube cryocooler. With a designed maximum swept volume of 60 cm~3, the compressor can provide the cryocooler with a pressure volume (PV) power of 400 W.Preliminary measurements of the compressor indicated that both an efficiency of 35%~55% and a pressure ratio of 1.3~1.4 could be obtained. The two-stage pulse tube cryocooler driven by this compressor achieved the lowest temperature of 14.2 K.

  10. Investigation on a Single-stage Coaxial Pulse Tube Cryocooler for Small Particle Detectors at CERN

    CERN Document Server

    Haug, F; Essler, J; Koettig, T; Wu, J H

    2009-01-01

    A single-stage coaxial pulse tube cryocooler has been developed for cooling small particle tracking detectors needed for future luminosity upgrades of the LHC. It is designed for remote operation in high radiation areas of the tunnel with restricted space. It features novel phase-adjusting mechanisms integrated into the warm flange. This flange is cooled with ambient air to reach a simple and compact design. The dimensions of the cold-finger are 24 mm diameter and 170 mm length. The measured no-load temperature is 52 K and the pulse tube cryocooler provides a cooling capacity of 5 W at 80 K.

  11. High-power Stirling-type pulse tube cryocooler: Observation and reduction of regenerator temperature-inhomogeneities

    Science.gov (United States)

    Dietrich, M.; Yang, L. W.; Thummes, G.

    2007-05-01

    A single stage Stirling-type pulse tube cryocooler driven by a 10 kW-class linear compressor was built and tested. During operation an azimuthal temperature inhomogeneity around the circumference of the regenerator was observed indicating a significant parasitic streaming in the regenerator. The nature of this streaming was examined and a numerical model based on the Sage software was created to understand its origin. It turns out that there is a critical operating condition where a self-preserving streaming starts to circulate in the regenerator. This critical condition is found to depend on the temperature gradient in the regenerator, the amount of mass flow and on the transverse thermal conductivity of the regenerator material. To overcome the negative effect of circulating streaming, the transverse heat conductance in the regenerator was increased by use of sandwich type fillings, where a part of the original stainless screens was replaced by materials with higher thermal conductance. Using these type regenerator fillings, the losses from streaming were significantly reduced and the refrigeration temperature was lowered to 34.5 K. Cooling powers of 50 W at 45 K and 200 W at 70 K are available with electric input powers of 6.3 kW and 8.6 kW, respectively.

  12. Performance of a 4 Kelvin pulse-tube cooled cryostat with dc SQUID amplifiers for bolometric detector testing

    CERN Document Server

    Barron, Darcy; Keating, Brian; Quillin, Ron; Stebor, Nathan; Wilson, Brandon

    2013-01-01

    The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of sensitivity required, these experiments use arrays of superconducting Transition Edge Sensor (TES) bolometers that are cooled to sub-Kelvin temperatures for photon-noise limited performance. These TES detectors are read out using low- noise SQUID amplifiers. To rapidly test these detectors and similar devices in a laboratory setting, we constructed a cryogenic refrigeration chain consisting of a commercial two-stage pulse-tube cooler, with a base temperature of 3 K, and a closed-cycle 3He/4He/3He sorption cooler, with a base temperature of 220 mK. A commercial dc SQUID system, with sensors cooled to 4 K, was used as a highly-sensitive cryogenic ammeter. Due to the extreme sensitivity of SQUIDs to changing magnetic fields, there are several challenges involving cooling them with puls...

  13. Analysis and comparison of different phase shifters for Stirling pulse tube cryocooler

    DEFF Research Database (Denmark)

    Lei, Tian; Pfotenhauer, John M.; Zhou, Wenjie

    2016-01-01

    Investigations of phase shifters and power recovery mechanisms are of sustainable interest for developing Stirling pulse tube cryocoolers (SPTC) with higher power density, more compact design and higher efficiency. This paper investigates the phase shifting capacity and the applications of four d...

  14. 150K - 200K miniature pulse tube cooler for micro satellites

    Energy Technology Data Exchange (ETDEWEB)

    Chassaing, Clément; Butterworth, James; Aigouy, Gérald [Air Liquide Advanced Technologies (AL-AT) - 38360 Sassenage (France); Daniel, Christophe [Centre National D' Etudes Spatiales (CNES) - 31401 Toulouse (France); Crespin, Maurice; Duvivier, Eric [STEEL électronique - 31220 Martres Tolosane (France)

    2014-01-29

    Air Liquide is working with the CNES and Steel électronique in 2013 to design, manufacture and test a Miniature Pulse Tube Cooler (MPTC) to cool infrared detectors for micro-satellite missions. The cooler will be particularly adapted to the needs of the CNES MICROCARB mission to study atmospheric Carbon Dioxide which presents absorption lines in the thermal near infrared, at 1.6 μm and 2.0 μm. The required cooler temperature is from 150 to 200K with cooling power between 1 and 3 watts. The overall electrical power budget including electronics is less than 20W with a 288-300K rejection temperature. Particular attention is therefore paid to optimizing overall system efficiency. The active micro vibration reduction system and thermal control systems already developed for the Air Liquide Large Pulse Tube Cooler (LPTC) are currently being implemented into a new high efficiency electronic architecture. The presented work concerns the new cold finger and electronic design. The cooler uses the compressor already developed for the 80K Miniature Pulse Tube Cryocooler. This Pulse Tube Cooler addresses the requirements of space missions where extended continuous operating life time (>5 years), low mass and low micro vibration levels are critical.

  15. Harmonic frequency mixing using high Tc superconductor Josephson junction mounted on pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A frequency mixing system including microwave coupling and intermediate frequency (IF) measurement arrangements is esigned. In lieu of liquid nitrogen, a pulse tube cryocooler is used to cool the whole system. With YBa2Cu3O7/Yttrium stabilized irconia (YBCO/YSZ) bicrystal Josephson junction as the mixing element, 36th harmonic frequency mixing at the 8 mm waveband is obtained.

  16. Study on a 10 W/90 K in-line pulse tube cryocooler

    Science.gov (United States)

    Zhang, Ankuo; Chen, Xi; Wu, Yi Nong; Zhang, Hua; Yang, Kaixiang

    2012-12-01

    A Stirling-type in-line pulse tube cryocooler (PTC) has been designed, built and tested at Shanghai Institute of Technical Physics (SITP), Chinese Academy of Sciences. This PTC prototype can obtain a low-noise cooling capacity of more than 10 W at around 90 K cold head temperature and is used for cooling a space-borne infrared photo detector. In order to achieve a highly efficient PTC, a simplified numerical simulation model has been established for design and optimization. The simulation results of the regenerator, pulse tube and inertance tube are analyzed in detail. Besides, some key parameters of the PTC are listed in the paper. The PTC's performances are tested at different operating frequencies from 42 Hz to 55 Hz and its reject temperature dependence is observed in the range of 290 K to 320 K. Furthermore, the map of the PTC's performance characteristics is presented.

  17. A high-efficiency coaxial pulse tube cryocooler with 500 W cooling capacity at 80 K

    Science.gov (United States)

    Hu, J. Y.; Zhang, L. M.; Zhu, J.; Chen, S.; Luo, E. C.; Dai, W.; Li, H. B.

    2014-07-01

    High-temperature superconductivity power-grid technologies require a highly reliable and efficient cryocooler with cooling power of 100 W to kilowatt level at liquid-nitrogen temperatures to produce cryogenic environments. This paper describes the design of a coaxial Stirling-type pulse tube cryocooler to meet this need. In the designed cryocooler, the regenerator and pulse tube are lengthened to avoid possible temperature inhomogeneity. In an experiment, the azimuthal temperature difference at the middle of the regenerator was less than 30 K. With 7.6 kW electric power input, the cryocooler offers more than 520 W cooling power at 80 K corresponding to a relative Carnot efficiency of 18.2%. When the cooling power was less than 370 W, the efficiency is higher than 20%.

  18. Theoretical and experimental investigations on the match between pulse tube cold fingers and linear compressors

    Science.gov (United States)

    Tan, Jun; Dang, Haizheng; Zhang, Lei

    2015-12-01

    The match between the cold finger and the linear compressor of the Stirling-type pulse tube cryocooler plays a vital role in optimizing the compressor efficiency and in improving the cold finger cooling performance. To reveal the match mechanism between the linear compressor and pulse tube cold finger (PTCF), detailed analyses have been made to understand the interactions between them. Based on the theoretical investigations, both of the design method of the PTCF to match the given linear compressor and a reverse method of the linear compressor to match the given PTCF have been proposed. In order to verify the validity of these theories and methods, actual PTCF and linear compressor are developed to match the existing linear compressor and PTCF, respectively. The experimental results show good agreements with the simulated ones.

  19. Development of a dry linear compressor for GM and pulse tube cryocoolers

    CERN Document Server

    Höhne, Jens

    2015-01-01

    Pressure Wave Systems GmbH has developed a dry compressor for GM and pulse tube cryocoolers. The concept is based on hydraulically driven metal bellows in which the Helium working gas is compressed. The system is operated in the region of 1 kW of electrical input power and has been successfully tested with a SHI RDK-101D GM cryocooler cold head. Set-up, performance and reliability of the compressor system will be discussed.

  20. Development of a dry linear compressor for GM and pulse tube cryocoolers

    Science.gov (United States)

    Hoehne, J.

    2015-12-01

    Pressure Wave Systems GmbH has developed a dry compressor for GM and pulse tube cryocoolers. The concept is based on hydraulically driven metal bellows in which the Helium working gas is compressed. The system is operated in the region of 1 kW of electrical input power and has been successfully tested with a SHI RDK-101D GM cryocooler cold head. Set-up, performance and reliability of the compressor system will be discussed.

  1. Evaluation of machine learning tools for inspection of steam generator tube structures using pulsed eddy current

    Science.gov (United States)

    Buck, J. A.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2017-02-01

    Degradation of nuclear steam generator (SG) tubes and support structures can result in a loss of reactor efficiency. Regular in-service inspection, by conventional eddy current testing (ECT), permits detection of cracks, measurement of wall loss, and identification of other SG tube degradation modes. However, ECT is challenged by overlapping degradation modes such as might occur for SG tube fretting accompanied by tube off-set within a corroding ferromagnetic support structure. Pulsed eddy current (PEC) is an emerging technology examined here for inspection of Alloy-800 SG tubes and associated carbon steel drilled support structures. Support structure hole size was varied to simulate uniform corrosion, while SG tube was off-set relative to hole axis. PEC measurements were performed using a single driver with an 8 pick-up coil configuration in the presence of flat-bottom rectangular frets as an overlapping degradation mode. A modified principal component analysis (MPCA) was performed on the time-voltage data in order to reduce data dimensionality. The MPCA scores were then used to train a support vector machine (SVM) that simultaneously targeted four independent parameters associated with; support structure hole size, tube off-centering in two dimensions and fret depth. The support vector machine was trained, tested, and validated on experimental data. Results were compared with a previously developed artificial neural network (ANN) trained on the same data. Estimates of tube position showed comparable results between the two machine learning tools. However, the ANN produced better estimates of hole inner diameter and fret depth. The better results from ANN analysis was attributed to challenges associated with the SVM when non-constant variance is present in the data.

  2. A Cryogen Recycler with Pulse Tube Cryocooler for Recondensing Helium and Nitrogen

    Science.gov (United States)

    Wang, C.; Lichtenwalter, B.

    2015-12-01

    We have developed a cryogen recycler using a 4 K pulse tube cryocooler for recondensing helium and nitrogen in a NMR magnet. The liquid helium cooled NMR magnet has a liquid nitrogen cooled radiation shield. The magnet boils off 0.84 L/day of liquid helium and 6 L/day of liquid nitrogen. The recycler is designed with both a liquid helium return tube and a liquid nitrogen return tube, which are inserted into the fill ports of liquid helium and nitrogen. Therefore the recycler forms closed loops for helium and nitrogen. A two-stage 4 K pulse tube cryocooler, Cryomech model PT407 (0.7W at 4.2 K), is selected for the recycler. The recycler was first tested with a Cryomech's test cryostat and resulted in the capacities of recondensing 8.2 L/day of nitrogen and liquefying 4 L/day of helium from room temperature gas. The recycler has been installed in the NMR magnet at University of Sydney since August, 2014 and continuously maintains a zero boil off for helium and nitrogen.

  3. a Study of a High Frequency Miniature Reservoir-Less Pulse Tube

    Science.gov (United States)

    Garaway, I.; Grossman, G.

    2008-03-01

    A miniature high frequency reservoir-less pulse tube cryocooler has been designed and tested in our laboratory. The cryocooler having a regenerator length of 12.0 mm and an overall volume of 2.3cc (excluding the compressor) reached a low temperature of 146K and provided 100mW of cooling at 160K. This experimental study shows that it is possible to miniaturize a pulse tube cryocooler to very short regenerator lengths by implementing a few basic principles: Most importantly, high operating frequencies at small tidal displacements, a regenerator matrix with small hydraulic diameters, and increased helium fill pressures. This study also shows that as the operating frequency of a miniature cryocooler increases, the reservoir becomes less necessary as a phase shifting device. At higher frequencies and appropriate inertance tube geometries, the impedance and capacitance of the inertance tube itself takes over the phase shifting task. An outline of the design and modeling principles is presented along with some details of the experimental apparatus and testing procedures.

  4. James Webb Space Telescope Mid Infra-Red Instrument Pulse-Tube Cryocooler Electronics

    Science.gov (United States)

    Harvey, D.; Flowers, T.; Liu, N.; Moore, K.; Tran, D.; Valenzuela, P.; Franklin, B.; Michaels, D.

    2013-01-01

    The latest generation of long life, space pulse-tube cryocoolers require electronics capable of controlling self-induced vibration down to a fraction of a newton and coldhead temperature with high accuracy down to a few kelvin. Other functions include engineering diagnostics, heater and valve control, telemetry and safety protection of the cryocooler subsystem against extreme environments and operational anomalies. The electronics are designed to survive the thermal, vibration, shock and radiation environment of launch and orbit, while providing a design life in excess of 10 years on-orbit. A number of our current generation high reliability radiation-hardened electronics units are in various stages of integration on several space flight payloads. This paper describes the features and performance of our latest flight electronics designed for the pulse-tube cryocooler that is the pre-cooler for a closed cycle Joule-Thomson cooler providing 6K cooling for the James Webb Space Telescope (JWST) Mid Infra-Red Instrument (MIRI). The electronics is capable of highly accurate temperature control over the temperature range from 4K to 15K. Self-induced vibration is controlled to low levels on all harmonics up to the 16th. A unique active power filter controls peak-to-peak reflected ripple current on the primary power bus to a very low level. The 9 kg unit is capable of delivering 360W continuous power to NGAS's 3-stage pulse-tube High-Capacity Cryocooler (HCC).

  5. Advances on a cryogen-free Vuilleumier type pulse tube cryocooler

    Science.gov (United States)

    Wang, Yanan; Zhao, Yuejing; Zhang, Yibing; Wang, Xiaotao; Vanapalli, Srinivas; Dai, Wei; Li, Haibing; Luo, Ercang

    2017-03-01

    This paper presents experimental results and numerical evaluation of a Vuilleumier (VM) type pulse tube cryocooler. The cryocooler consists of three main subsystems: a thermal compressor, a low temperature pulse tube cryocooler, and a Stirling type precooler. The thermal compressor, similar to that in a Vuilleumier cryocooler, is used to drive the low temperature stage pulse tube cryocooler. The Stirling type precooler is used to establish a temperature difference for the thermal compressor to generate pressure wave. A lowest no-load temperature of 15.1 K is obtained with a pressure ratio of 1.18, a working frequency of 3 Hz and an average pressure of 2.45 MPa. Numerical simulations have been performed to help the understanding of the system performance. With given experimental conditions, the simulation predicts a lowest temperature in reasonable agreement with the experimental result. Analyses show that there is a large discrepancy in the pre-cooling power between experiments and calculation, which requires further investigation.

  6. Improved Performance of an Indigenous Stirling Type Pulse Tube Cooler and Pressure Wave Generator

    Science.gov (United States)

    Kumar, J. Kranthi; Jacob, S.; Karunanithi, R.; Narasimham, G. S. V. L.; Damu, C.; Praveen, T.; Samir, M.

    Sustained efforts have been made in our laboratory to improve the performance of an indigenously developed pressure wave gen- erator by reducing the mechanical losses and the required input power. An acoustically matching pulse tube cooler, with a design target of 0.5 W at 80 K, was designed using Sage and experience gained from previous studies. The pulse tube cooler was fabri- cated and tested. The effect of regenerator stacking pattern on the cooler performance was studied by filling the regenerator with mesh of the same size #400 and with multi meshes #250, 325, 400. In present experiments, regenerator with #400 mesh at 30 bar filling pressure performed better with more energy efficiency. A no load temperature of 74 K was achieved with input power of 59 W corresponding to a cooling power of 0.22 W at 80 K. Parasitic heat load to the cooler was measured be 0.68 W. This heat load is primarily by heat conduction through the regenerator and pulse tube wall. By reducing the wall thickness from 0.30 mm to 0.15 mm, the parasitic loads can be reduced by 50%.

  7. James Webb Space Telescope Mid Infra-Red Instrument Pulse-Tube Cryocooler Electronics

    Science.gov (United States)

    Harvey, D.; Flowers, T.; Liu, N.; Moore, K.; Tran, D.; Valenzuela, P.; Franklin, B.; Michaels, D.

    2013-01-01

    The latest generation of long life, space pulse-tube cryocoolers require electronics capable of controlling self-induced vibration down to a fraction of a newton and coldhead temperature with high accuracy down to a few kelvin. Other functions include engineering diagnostics, heater and valve control, telemetry and safety protection of the cryocooler subsystem against extreme environments and operational anomalies. The electronics are designed to survive the thermal, vibration, shock and radiation environment of launch and orbit, while providing a design life in excess of 10 years on-orbit. A number of our current generation high reliability radiation-hardened electronics units are in various stages of integration on several space flight payloads. This paper describes the features and performance of our latest flight electronics designed for the pulse-tube cryocooler that is the pre-cooler for a closed cycle Joule-Thomson cooler providing 6K cooling for the James Webb Space Telescope (JWST) Mid Infra-Red Instrument (MIRI). The electronics is capable of highly accurate temperature control over the temperature range from 4K to 15K. Self-induced vibration is controlled to low levels on all harmonics up to the 16th. A unique active power filter controls peak-to-peak reflected ripple current on the primary power bus to a very low level. The 9 kg unit is capable of delivering 360W continuous power to NGAS's 3-stage pulse-tube High-Capacity Cryocooler (HCC).

  8. Low Temperature Regenerators for Zero Boil-Off Liquid Hydrogen Pulse Tube Cryocoolers

    Science.gov (United States)

    Salerno, Louis J.; Kashani, Ali; Helvensteijn, Ben; Kittel, Peter; Arnoldm James O. (Technical Monitor)

    2002-01-01

    Recently, a great deal of attention has been focused on zero boil-off (ZBO) propellant storage as a means of minimizing the launch mass required for long-term exploration missions. A key component of ZBO systems is the cooler. Pulse tube coolers offer the advantage of zero moving mass at the cold head, and recent advances in lightweight, high efficiency cooler technology have paved the way for reliable liquid oxygen (LOx) temperature coolers to be developed which are suitable for flight ZBO systems. Liquid hydrogen (LH2) systems, however, are another matter. For ZBO liquid hydrogen systems, cooling powers of 1-5 watts are required at 20 K. The final development from tier for these coolers is to achieve high efficiency and reliability at lower operating temperatures. Most of the life-limiting issues of flight Stirling and pulse tube coolers are associated with contamination, drive mechanisms, and drive electronics. These problems are well in hand in the present generation coolers. The remaining efficiency and reliability issues reside with the low temperature regenerators. This paper will discuss advances to be made in regenerators for pulse tube LH2 ZBO coolers, present some historical background, and discuss recent progress in regenerator technology development using alloys of erbium.

  9. Pulsed electron beam propagation in gases under pressure of 6.6 kPa in drift tube

    Science.gov (United States)

    Kholodnaya, G. E.; Sazonov, R. V.; Ponomarev, D. V.; Remnev, G. E.; Poloskov, A. V.

    2017-02-01

    This paper presents the results of an investigation of pulsed electron beam transport propagated in a drift tube filled with different gases (He, H2, N2, Ar, SF6, and CO2). The total pressure in the drift tube was 6.6 kPa. The experiments were carried out using a TEA-500 pulsed electron accelerator. The electron beam was propagated in the drift tube composed of two sections equipped with reverse current shunts. Under a pressure of 6.6 kPa, the maximum value of the electron beam charge closed on the walls of the drift tube was recorded when the beam was propagated in hydrogen and carbon dioxide. The minimum value of the electron beam charge closed on the walls of the drift tube was recorded for sulfur hexafluoride. The visualization of the pulsed electron beam energy losses onto the walls of the drift chamber was carried out using radiation-sensitive film.

  10. Finite element modeling and analysis of electro-magnetic pulse welding of aluminium tubes to steel bars

    Science.gov (United States)

    Kumar, Ramesh; Doley, Jyoti; Kore, Sachine

    2016-10-01

    Magnetic pulse welding is a high-speed, solid-state welding process that is applicable to sheets or tube-to-tube or tube-to-bar configurations. In this article we discuss about the MPW process modeling and simulation for welding Al tubes to steel bars. Finite element simulation was done to weld 6061 Al tubes of 1.65 mm wall thickness to 1010 steel bars of a 47.6 mm nominal diameter. Simulation results indicate that Al tubes can be successfully welded to steel bars using MPW. It is found that the standoff distance between the Al tube and the steel bar i.e. gap between inner diameter of Al tube and diameter of steel bar is a dominant factor for achieving a sound weld. The addition of receding angles to the bars can promote MPW weldability window.

  11. Analysis of pulsed eddy current data using regression models for steam generator tube support structure inspection

    Science.gov (United States)

    Buck, J. A.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2016-02-01

    Nuclear steam generators (SGs) are a critical component for ensuring safe and efficient operation of a reactor. Life management strategies are implemented in which SG tubes are regularly inspected by conventional eddy current testing (ECT) and ultrasonic testing (UT) technologies to size flaws, and safe operating life of SGs is predicted based on growth models. ECT, the more commonly used technique, due to the rapidity with which full SG tube wall inspection can be performed, is challenged when inspecting ferromagnetic support structure materials in the presence of magnetite sludge and multiple overlapping degradation modes. In this work, an emerging inspection method, pulsed eddy current (PEC), is being investigated to address some of these particular inspection conditions. Time-domain signals were collected by an 8 coil array PEC probe in which ferromagnetic drilled support hole diameter, depth of rectangular tube frets and 2D tube off-centering were varied. Data sets were analyzed with a modified principal components analysis (MPCA) to extract dominant signal features. Multiple linear regression models were applied to MPCA scores to size hole diameter as well as size rectangular outer diameter tube frets. Models were improved through exploratory factor analysis, which was applied to MPCA scores to refine selection for regression models inputs by removing nonessential information.

  12. Inspection of ferromagnetic support structures from within alloy 800 steam generator tubes using pulsed eddy current

    Science.gov (United States)

    Buck, Jeremy Andrew

    Nondestructive testing is a critical aspect of component lifetime management. Nuclear steam generator (SG) tubes are the thinnest barrier between irradiated primary heat transport system and the secondary heat transport system, whose components are not rated for large radiation fields. Conventional eddy current testing (ECT) and ultrasonic testing are currently employed for inspecting SG tubes, with the former doing most inspections due to speed and reliability based on an understanding of how flaws affect coil impedance parameters when conductors are subjected to harmonically induced currents. However, when multiple degradation modes are present simultaneously near ferromagnetic materials, such as tube fretting, support structure corrosion, and magnetite fouling, ECT reliability decreases. Pulsed eddy current (PEC), which induces transient eddy currents via square wave excitation, has been considered in this thesis to simultaneously examine SG tube and support structure conditions. An array probe consisting of a central driver, coaxial with the tube, and an array of 8 sensing coils, was used in this thesis to perform laboratory measurements. The probe was delivered from the inner diameter (ID) of the SG tube, where support hole diameter, tube frets, and 2D off-centering were varied. When considering two variables simultaneously, scores obtained from a modified principal components analysis (MPCA) were sufficient for parameter extraction. In the case of hole ID variation with two dimensional tube off-centering (three parameters), multiple linear regression (MLR) of the MPCA scores provided good estimates of parameters. However, once a fourth variable, outer diameter tube frets, was introduced, MLR proved insufficient. Artificial neural networks (ANNs) were investigated in order to perform pattern recognition on the MPCA scores to simultaneously extract the four measurement parameters from the data. All models throughout this thesis were created and validated using

  13. Pulse wave attenuation measurement by linear and nonlinear methods in nonlinearly elastic tubes.

    Science.gov (United States)

    Bertram, C D; Pythoud, F; Stergiopulos, N; Meister, J J

    1999-04-01

    Reasons for the continuing difficulty in making definitive measurements of pulse wave attenuation in elastic tubes and arteries in the presence of reflections are sought. The measurement techniques available were re-examined in elastic tubes mimicking the arterial compliance nonlinearity, under conditions of strong reflection. The pulse was of physiological shape, and two different pulse amplitudes in the physiological range were used. Measurements of pressure, flow-rate and diameter pulsation allowed the deployment of four of the classical linear methods of analysis. In addition, a method of separating the forward- and backward-travelling waves that does not require linearising assumptions was used, and the attenuation in the forward and reverse directions was calculated from the resulting waveforms. Overall, the results obtained here suggest that a fully satisfactory way of measuring arterial attenuation has yet to be devised. The classical linear methods all provided comparable attenuation estimates in terms of average value and degree of scatter across frequency. Increased scatter was generally found at the higher pulse amplitude. When the forward waveforms from the separation were similarly compared in terms of frequency components, the average value at energetic harmonics was similar to both the value indicated by the linear methods and the values predicted from linear theory on the basis of estimated viscous and viscoelastic parameter data. The backward waveforms indicated a physically unreasonable result, attributed as the expression for this technique of the same difficulties that normally manifest in scatter. Data in the literature suggesting that one of the classical methods, the three-point, systematically over-estimates attenuation were not supported, but it was confirmed that this method becomes prone to negative attenuation estimates at low harmonics as pulse amplitude increases. Although the goal of definitive attenuation measurement remains elusive

  14. A nanoscale vacuum-tube diode triggered by few-cycle laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Takuya, E-mail: takuya.higuchi@fau.de; Hommelhoff, Peter, E-mail: peter.hommelhoff@physik.uni-erlangen.de [Department of Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Staudtstrasse 1, D-91058 Erlangen (Germany); Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Strasse 1, D-85748 Garching (Germany); Maisenbacher, Lothar; Liehl, Andreas; Dombi, Péter [Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Strasse 1, D-85748 Garching (Germany)

    2015-02-02

    We propose and demonstrate a nanoscale vacuum-tube diode triggered by few-cycle near-infrared laser pulses. It represents an ultrafast electronic device based on light fields, exploiting near-field optical enhancement at surfaces of two metal nanotips. The sharper of the two tips displays a stronger field-enhancement, resulting in larger photoemission yields at its surface. One laser pulse with a peak intensity of 4.7 × 10{sup 11 }W/cm{sup 2} triggers photoemission of ∼16 electrons from the sharper cathode tip, while emission from the blunter anode tip is suppressed by 19 dB to ∼0.2 electrons per pulse. Thus, the laser-triggered current between two tips exhibit a rectifying behavior, in analogy to classical vacuum-tube diodes. According to the kinetic energy of the emitted electrons and the distance between the tips, the total operation time of this laser-triggered nanoscale diode is estimated to be below 1 ps.

  15. Amorphous carbon film deposition on inner surface of tubes using atmospheric pressure pulsed filamentary plasma source

    CERN Document Server

    Pothiraja, Ramasamy; Awakowicz, Peter

    2011-01-01

    Uniform amorphous carbon film is deposited on the inner surface of quartz tube having the inner diameter of 6 mm and the outer diameter of 8 mm. A pulsed filamentary plasma source is used for the deposition. Long plasma filaments (~ 140 mm) as a positive discharge are generated inside the tube in argon with methane admixture. FTIR-ATR, XRD, SEM, LSM and XPS analyses give the conclusion that deposited film is amorphous composed of non-hydrogenated sp2 carbon and hydrogenated sp3 carbon. Plasma is characterized using optical emission spectroscopy, voltage-current measurement, microphotography and numerical simulation. On the basis of observed plasma parameters, the kinetics of the film deposition process is discussed.

  16. Development of a 4.5 K Pulse Tube Cryocooler for Superconducting Electronics

    Science.gov (United States)

    Nast, Ted; Olson, Jeff; Champagne, Patrick; Mix, Jack; Evtimov, Bobby; Roth, Eric; Collaco, Andre

    2008-03-01

    Lockheed Martin's (LM) Advanced Technology Center (ATC) has developed a four stage pulse tube cryocooler (stirling-type pulse tube system) to provide cooling at 4.5 K for superconducting digital electronics communications programs. These programs utilize superconducting niobium integrated circuits [1, 2]. A prior ATC 4 stage unit has provided cooling to 3.8 K. [3] The relatively high cooling loads for the present program led us to a new design which improves the 4.5 K power efficiency over prior systems. This design includes a unique pulse tube approach using both He-3 and He-4 working gas in two compression spaces. The compressor utilizes our standard moving magnet linear motor, clearance seal and flexure bearing system. The system is compact, lightweight and reliable and utilizes our aerospace cooler technology to provide unlimited lifetime. The unit is a proof of concept, but the construction is at an engineering model level. Follow on activities for improvements of performance and more compact packaging and future production for ground based communication systems is anticipated. This paper presents the experimental results at various cooling conditions. Primary results are shown for HYPRES cooling requirements and data is also included at lower cooling loads that may be required for future space missions. The system provides a maximum of 42 mW @ 4.5 K and a no load temperature of 3 K. The majority of this work was subcontracted by HYPRES and funded by the Army and Navy. A small part of this effort to obtain data at lower cooling loads (1-10 mW @ 4.5 K) was funded by LM internal funds.

  17. An ice rink refrigeration system based on CO{sub 2} as secondary fluid in copper tubes

    Energy Technology Data Exchange (ETDEWEB)

    Shahzad, Khuram [Royal Inst. of Technology, Stockholrn (Sweden). Dept. of Energy Technology

    2006-06-15

    This report is a study of the use of copper tubes with CO{sub 2} as heat transfer fluid in ice rink applications. Copper tubes can be rolled rather easily up to the required length which decreases installation cost and simplifies the procedure. A test ice rink was built at IUC Ref Centre, Katrineholm with copper tubes. FEMLAB and EES are two softwares that were used for analysis. The comparison between 12.7 mm diameter copper tubes with and without plastic foil cover, 9.5 mm diameter copper tubes with and without plastic foil cover, 21.3 mm diameter steel pipes and 25 mm diameter plastic pipes is presented in the report. The reason to have plastic foil over copper tubes is to avoid the minor risk of chemical corrosion. Furthermore the foil serves as mechanical wear protection as well, which in this case could appear if rubbing would occur due to thermal expansion and contraction. It is found that 12.7 mm copper tube with plastic foil is good choice in terms of heat transfer. At rated heat flux of 100 W/m{sup 2} and with a pitch of 100 mm, it is 0.18 deg C better than 9.5 mm copper tube with plastic foil. This report includes the investigation which shows that there is no danger of movement of copper tubes inside the rink bed due to thermal expansion and contraction during operation. It also includes the comparison of average Friedel pressure drop model and average homogeneous pressure drop model with experimental results. Average Friedel pressure drop method gave good results. It predicted 20 to 25 % higher pressure drop at lower CR and about 60 % at higher CR than the experimental results for 120 meter long and 12.7 mm diameter copper tubes. 120 meter long copper tubes are good choice; as header can be placed on short side of the ice rink. It will reduce the header length and connections to half. FEMLAB modelling for conduction heat transfer gave good results and can be used as a tool for design and optimization. The optimization of the pitch of the copper tubes

  18. Study on a 5.0 W/80 K single stage Stirling type pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    Zhi-hua GAN; Guo-jun LIU; Ying-zhe WU; Qiang CAO; Li-min QIU; Guo-bang CHEN; J.M.PFOTENHAUER

    2008-01-01

    A single stage Stifling pulse tube cryocooler was designed based on REGEN 3.2 and fabricated for testing.The experimental results show that the cooler can provide a cooling capacity of 5.0 W at 79.1 K,and produce a no-load temperature of 57.0 K,operating with an average pressure of 2.50 Mpa and a frequency of 60 Hz,performance results that are very close to the calculated values.The cryoeooler can be cooled from room temperature to 80 K in 8.5 min.The fast cooldown time is a result of the small regenerator.

  19. A coaxial tube model of the cerebrospinal fluid pulse propagation in the spinal column.

    Science.gov (United States)

    Cirovic, Srdjan

    2009-02-01

    The dynamics of the movement of the cerebrospinal fluid (CSF) may play an important role in the genesis of pathological neurological conditions such as syringomyelia, which is characterized by the presence of a cyst (syrinx) in the spinal cord. In order to provide sound theoretical grounds for the hypotheses that attribute the formation and growth of the syrinx to impediments to the normal movement of the CSF, it is necessary to understand various modes through which CSF pulse in the spinal column propagates. Analytical models of small-amplitude wave propagation in fluid-filled coaxial tubes, where the outer tube represents dura, the inner tube represents the spinal cord, and the fluid is the CSF, have been used to that end. However, so far, the tendency was to model one of the two tubes as rigid and to neglect the effect of finite thickness of the tube walls. The aim of this study is to extend the analysis in order to address these two potentially important issues. To that end, classical linear small-amplitude analysis of wave propagation was applied to a system consisting of coaxial tubes of finite thickness filled with inviscid incompressible fluid. General solutions to the governing equations for the case of harmonic waves in the long wave limit were replaced with the boundary conditions to yield the characteristic (dispersion) equation for the system. The four roots of the characteristic equation correspond to four modes of wave propagation, of which the first three are associated with significant motion of the CSF. For the normal range of parameters the speeds of the four modes are c(1)=13 ms, c(2)=14.7 ms, c(3)=30.3 ms, and c(4)=124.5 ms, which are well within the range of values previously reported in experimental and theoretical studies. The modes with the highest and the lowest speeds of propagation can be attributed to the dura and the spinal cord, respectively, whereas the remaining two modes involve some degree of coupling between the two. When the

  20. An Optical Cryostat with $^{3}$He Sorption Refrigerator

    CERN Document Server

    Trofimov, V N; Perminov, V G; Vdovin, V F; Vystavkin, A N

    2005-01-01

    An optical cryostat with $^{3}$He sorption refrigerator is described. The refrigerator is mounted on a copper plate with temperature 4.2 K in vacuum volume of a helium cryostat. It has two sorption steps: the first with working gas $^4$He is intended for condensation of $^{3}$He, the second with $^{3}$He for cooling down to 0.3 K. The cryostat is an independent device that does not contain the external gas communications aimed at reaching low temperatures, and working gases are stored in cans integrated with the cryostat. The refrigerator can be used together with the cryocoolers of Gifford--McMahon or pulse tube types with cooling power not less than 0.3 W/4 K, thus allowing operating without any liquid cryoagents.

  1. Mechanisms of amplification of ultrashort electromagnetic pulses in gyrotron traveling wave tube with helically corrugated waveguide

    Science.gov (United States)

    Ginzburg, N. S.; Zotova, I. V.; Sergeev, A. S.; Zaslavsky, V. Yu.; Zheleznov, I. V.; Samsonov, S. V.; Mishakin, S. V.

    2015-11-01

    A time-domain self consistent theory of a gyrotron traveling wave tube with a helically corrugated operating waveguide has been developed. Based on this model, the process of short pulse amplification was studied in regimes of grazing and intersection of the dispersion curves of the electromagnetic wave and the electron beam. In the first case, the possibility of amplification without pulse form distortion was demonstrated for the pulse spectrum width of the order of the gain bandwidth. In the second case, when the electrons' axial velocity was smaller than the wave's group velocity, it was shown that the slippage of the incident signal with respect to the electron beam provides feeding of the signal by "fresh" electrons without initial modulation. As a result, the amplitude of the output pulse can exceed the amplitude of its saturated value for the case of the grazing regime, and, for optimal parameters, the peak output power can be even larger than the kinetic power of the electron beam.

  2. Mechanisms of amplification of ultrashort electromagnetic pulses in gyrotron traveling wave tube with helically corrugated waveguide

    Energy Technology Data Exchange (ETDEWEB)

    Ginzburg, N. S., E-mail: ginzburg@appl.sci-nnov.ru; Zaslavsky, V. Yu. [Institute of Applied Physics of the Russian Academy of Sciences, 46 Ul' yanov Str., 603950 Nizhny Novgorod (Russian Federation); Nizhny Novgorod State University, 23 Gagarin Ave., 603950 Nizhny Novgorod (Russian Federation); Zotova, I. V.; Sergeev, A. S.; Zheleznov, I. V.; Samsonov, S. V.; Mishakin, S. V. [Institute of Applied Physics of the Russian Academy of Sciences, 46 Ul' yanov Str., 603950 Nizhny Novgorod (Russian Federation)

    2015-11-15

    A time-domain self consistent theory of a gyrotron traveling wave tube with a helically corrugated operating waveguide has been developed. Based on this model, the process of short pulse amplification was studied in regimes of grazing and intersection of the dispersion curves of the electromagnetic wave and the electron beam. In the first case, the possibility of amplification without pulse form distortion was demonstrated for the pulse spectrum width of the order of the gain bandwidth. In the second case, when the electrons' axial velocity was smaller than the wave's group velocity, it was shown that the slippage of the incident signal with respect to the electron beam provides feeding of the signal by “fresh” electrons without initial modulation. As a result, the amplitude of the output pulse can exceed the amplitude of its saturated value for the case of the grazing regime, and, for optimal parameters, the peak output power can be even larger than the kinetic power of the electron beam.

  3. Development of a 4 K Stirling-Type Pulse Tube Cryocooler for a Mobile Terahertz Detection System

    Science.gov (United States)

    Bradley, P. E.; Gerecht, E.; Radebaugh, R.; Garaway, I.

    2010-04-01

    We discuss in this paper the design and development of a 4 K Stirling-type pulse tube cryocooler for a mobile terahertz detection system. This system integrates new heterodyne detector technology at terahertz frequencies with advancements of Stirling-type pulse tube technology that brings the advent of cooled detector sensitivities in a mobile, compact, and long duration operation system without degradation of sensitivity. To achieve this goal we reduced overall system size, input power, and temperature fluctuations and mechanical vibrations in order to maintain the detector sensitivity. The Stirling-type pulse tube cryocooler developed for this system is a hybrid design employing a He-4 pulse-tube cryocooler operating at 60 Hz and 2.5 MPa average pressure that precools a He-3 pulse tube cryocooler operating at 30 Hz and 1.0 MPa average pressure to achieve 4 K cooling for the terahertz receiver. The He-4 cryocooler employs stainless steel mesh regenerators for the first stage and ErPr spheres for the second stage, while the He-3 cryocooler employs stainless mesh for the first stage and ErPr spheres for the second stage with a layered rare-earth third stage regenerator. Design details and cooler performance goals are discussed.

  4. Design of High Frequency Pulse Tube Cryocooler for Onboard Space Applications

    Science.gov (United States)

    Srikanth, Thota; Padmanabhan; Gurudath, C. S.; Amrit, A.; Basavaraj, S.; Dinesh, K.

    2017-02-01

    To meet the growing demands of on-board applications such as cooling meteorological payloads and the satellite operational constraints like power, lower mass, reduced size and redundancy; a Pulse Tube Cryocooler (PTC) is designed by arriving at an operating frequency of 100 Hz and Helium gas pressure of 35 bar based on insights obtained from combination of phasor diagram, pulse tube and regenerator geometries with overall system mass of ≤ 2.0 kg. High frequency operation would allow reducing the size and mass of pressure wave modulator for a given input power. High Frequency also helps in reducing the volume of regenerator for a given cooling power, which increases the power density and leads to faster cool down. A component level modelling of the regenerator for optimising length and diameter for maximum Coefficient of Performance (COP) is carried out using REGEN3.3. The overall system level modelling of PTC is carried out using 1-D software SAGE. The cold end mass flow rate of the optimised regenerator is taken as reference for the system modelling. The performance achieved in REGEN3.3 is 2.15 W of net heat lift against the performance of 1.02 W of net heat lift at 80 K in SAGE.

  5. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    Science.gov (United States)

    Chen, L. B.; Liu, S. X.; Gu, K. X.; Zhou, Y.; Wang, J. J.

    2015-12-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper.

  6. Development of a Space-Type 4-Stage Pulse Tube Cryocooler for Very Low Temperature

    Science.gov (United States)

    Olson, J. R.; Moore, M.; Champagne, P.; Roth, E.; Evtimov, B.; Jensen, J.; Collaço, A.; Nast, T.

    2006-04-01

    The Lockheed Martin Advanced Technology Center (LMATC) has built and tested a 4-stage pulse tube cryocooler, which provides simultaneous cooling at 6 K and 18 K. The cryocooler is designed to meet NASA's cryocooler needs for low temperature, with immediate application to the Terrestrial Planet Finder, Constellation-X, and other future space-science missions. The simplicity with LMATC's approach of the single compressor, coldhead, and electronic controller makes it very appealing for applications requiring high reliability. It further allows the system to be readily modified for different program requirements. The LM pulse tube is a simple 4-stage coldhead with no moving parts, driven by a long-life linear flexure-bearing clearance-seal compressor. The cryocooler is designed to provide 20 mW of cooling at 6 K and 150 mW cooling at 18 K while rejecting heat at 290 K. Performance data is presented, showing excellent cryocooler performance, meeting JPL's cooling requirements, and achieving a no-load temperature below 4 K. This work was funded by the Jet Propulsion Laboratory's Advanced Cryocooler Technology Development Program (ACTDP), Ron G. Ross, Contract Manager.

  7. Analysis and comparison of different phase shifters for Stirling pulse tube cryocooler

    Science.gov (United States)

    Lei, Tian; Pfotenhauer, John M.; Zhou, Wenjie

    2016-12-01

    Investigations of phase shifters and power recovery mechanisms are of sustainable interest for developing Stirling pulse tube cryocoolers (SPTC) with higher power density, more compact design and higher efficiency. This paper investigates the phase shifting capacity and the applications of four different phase shifters, including conventional inertance tube, gas-liquid and spring-oscillator phase shifters, as well as a power recovery displacer. Distributed models based on the electro-acoustic analogy are developed to estimate the phase shifting capacity and the acoustic power dissipation of the three phase shifters without power recovery. The results show that both gas-liquid and spring-oscillator phase shifters have the distinctive capacity of phase shifting with a significant reduction in the inertial component length. Furthermore, full distributed models of SPTCs connected with different phase shifters are developed. The cooling performance of SPTCs using all four phase shifters are presented and typical phase relations are analyzed. The comparison reveals that the power recovery displacer with a more complicated configuration provides the highest efficiency. The gas-liquid and spring-oscillator phase shifters show equivalent efficiency compared with the inertance tube phase shifter. Approximately 10-20% of the acoustic power is dissipated by the phase shifters without power recovery, while 15-20% of the acoustic power can be recovered by the power recovery displacer, leading to a maximum coefficient of performance (COP) above 0.14 at 80 K. A merit analysis is also done by presenting the pros and cons of different phase shifters.

  8. Simple Two-Dimensional Corrections for One-Dimensional Pulse Tube Models

    Science.gov (United States)

    Lee, J. M.; Kittel, P.; Timmerhaus, K. D.; Radebaugh, R.

    2004-01-01

    One-dimensional oscillating flow models are very useful for designing pulse tubes. They are simple to use, not computationally intensive, and the physical relationship between temperature, pressure and mass flow are easy to understand when used in conjunction with phasor diagrams. They do not possess, however, the ability to directly calculate thermal and momentum diffusion in the direction transverse to the oscillating flow. To account for transverse effects, lumped parameter corrections, which are obtained though experiment, must be used. Or two-dimensional solutions of the differential fluid equations must be obtained. A linear two-dimensional solution to the fluid equations has been obtained. The solution provides lumped parameter corrections for one-dimensional models. The model accounts for heat transfer and shear flow between the gas and the tube. The complex Nusselt number and complex shear wall are useful in describing these corrections, with phase relations and amplitudes scaled with the Prandtl and Valensi numbers. The calculated ratio, a, between a two-dimensional solution of the oscillating temperature and velocity and a one-dimensional solution for the same shows a scales linearly with Va for Va less than 30. In this region alpha less than 0.5, that is, the enthalpy flow calculated with a two-dimensional model is 50% of a calculation using a one-dimensional model. For Va greater than 250, alpha = 0.8, showing that diffusion is still important even when it is confined to a thing layer near the tube wall.

  9. Correlations of Two-phase Friction of Refrigerant in Horizontal Smooth Tube with 2.5 mm inside Diameter

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Two-phase flow pressure drop measurements are made during phase change heat transfer process of R-22 in small horizontal smooth tubes with 2. 5 mm inside diameter.Conclusions are drawn that the quality corresponding to pressure gradient peak value of small tubes became higher than that of large tubes and that effects of quality on pressure drop become weak as the increase of mass flux.The experiment data are compared with predicted values of the state-of-the-art correlations from the open literature,which indicates that most of the state-of-the-art correlations fail to predict the present experimental data. Chisholm model shows a relatively better predictive ability than the other empirical correlations because it has the lowest mean deviation of 26.7%. But the predicted values of Chisholm model are 50% lower than experimental data when quality becomes higher. In this regard, an new empirical correlation based on Chisholm model is developed and this modified Chisholm correlation can describe 95% of the present data with ± 20% mean deviations.

  10. Pressure and Thrust Measurements of a High-Frequency Pulsed Detonation Tube

    Science.gov (United States)

    Nguyen, N.; Cutler, A. D.

    2008-01-01

    This paper describes measurements of a small-scale, high-frequency pulsed detonation tube. The device utilized a mixture of H2 fuel and air, which was injected into the device at frequencies of up to 1200 Hz. Pulsed detonations were demonstrated in an 8-inch long combustion volume, at about 600 Hz, for the quarter wave mode of resonance. The primary objective of this experiment was to measure the generated thrust. A mean value of thrust was measured up to 6.0 lb, corresponding to H2 flow based specific impulse of 2970 s. This value is comparable to measurements in H2-fueled pulsed detonation engines (PDEs). The injection and detonation frequency for this new experimental case was much higher than typical PDEs, where frequencies are usually less than 100 Hz. The compact size of the device and high frequency of detonation yields a thrust-per-unit-volume of approximately 2.0 pounds per cubic inch, and compares favorably with other experiments, which typically have thrust-per-unit-volume of order 0.01 pound per cubic inch. This much higher volumetric efficiency results in a potentially much more practical device than the typical PDE, for a wide range of potential applications, including high-speed boundary layer separation control, for example in hypersonic engine inlets, and propulsion for small aircraft and missiles.

  11. Experimental study on the pressure and pulse wave propagation in viscoelastic vessel tubes-effects of liquid viscosity and tube stiffness.

    Science.gov (United States)

    Ikenaga, Yuki; Nishi, Shohei; Komagata, Yuka; Saito, Masashi; Lagrée, Pierre-Yves; Asada, Takaaki; Matsukawa, Mami

    2013-11-01

    A pulse wave is the displacement wave which arises because of ejection of blood from the heart and reflection at vascular bed and distal point. The investigation of pressure waves leads to understanding the propagation characteristics of a pulse wave. To investigate the pulse wave behavior, an experimental study was performed using an artificial polymer tube and viscous liquid. A polyurethane tube and glycerin solution were used to simulate a blood vessel and blood, respectively. In the case of the 40 wt% glycerin solution, which corresponds to the viscosity of ordinary blood, the attenuation coefficient of a pressure wave in the tube decreased from 4.3 to 1.6 dB/m because of the tube stiffness (Young's modulus: 60 to 200 kPa). When the viscosity of liquid increased from approximately 4 to 10 mPa·s (the range of human blood viscosity) in the stiff tube, the attenuation coefficient of the pressure wave changed from 1.6 to 3.2 dB/m. The hardening of the blood vessel caused by aging and the increase of blood viscosity caused by illness possibly have opposite effects on the intravascular pressure wave. The effect of the viscosity of a liquid on the amplitude of a pressure wave was then considered using a phantom simulating human blood vessels. As a result, in the typical range of blood viscosity, the amplitude ratio of the waves obtained by the experiments with water and glycerin solution became 1:0.83. In comparison with clinical data, this value is much smaller than that seen from blood vessel hardening. Thus, it can be concluded that the blood viscosity seldom affects the attenuation of a pulse wave.

  12. High-frequency operation and miniaturization aspects of pulse-tube cryocoolers

    NARCIS (Netherlands)

    Vanapalli, Srinivas

    2008-01-01

    Cryocoolers are small refrigerators capable of achieving useful refrigeration below 120 K. Recent developments in the field of high Tc superconductors spawned a wide range of applications such as terahertz sensors, SQUIDS, low noise amplifiers, filters for microwave applications and many more. These

  13. Finite element modeling of wall-loss sizing in a steam generator tube using a pulsed eddy current probe

    Science.gov (United States)

    Babbar, V. K.; Lepine, B.; Buck, J.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2015-03-01

    Inspection of steam generator (SG) tubes by conventional eddy current may, in general, involve analysis of indications from volumetric wall loss, cracks, fouling and support-plate degradation; however, it may be difficult to size or quantify effects from support-to-tube gap and tube tilt, especially in the presence of support plates. Pulsed eddy current (PEC) technology is being developed to investigate such complex tube and flaw geometries. The present work employs finite element modeling to investigate the effectiveness of PEC in identifying and sizing the outer diameter wall-loss in SG tubes. The signals analyzed using a modified principal components analysis (PCA) method reveal the potential success of a PEC-PCA combination to produce scores that can be used to size the wall-loss in the presence of support plates. The modeling results are in good agreement with experimental observations.

  14. A 63 K phase change unit integrating with pulse tube cryocoolers

    Science.gov (United States)

    Chunhui, Kong; Liubiao, Chen; Sixue, Liu; Yuan, Zhou; Junjie, Wang

    2017-02-01

    This article presents the design and computer model results of an integrated cooler system which consists of a single stage pulse tube cryocooler integrated with a small amount of a phase change material. A cryogenic thermal switch was used to thermally connect the phase change unit to the cold end of the cryocooler. During heat load operation, the cryogenic thermal switch is turned off to avoid vibrations. The phase change unit absorbs heat loads by melting a substance in a constant pressure-temperature-volume process. Once the substance has been melted, the cryogenic thermal turned on, the cryocooler can then refreeze the material. Advantages of this type of cooler are no vibrations during sensor operations; the ability to absorb increased heat loads; potentially longer system lifetime; and a lower mass, volume and cost. A numerical model was constructed from derived thermodynamic relationships for the cooling/heating and freezing/melting processes.

  15. Cryogenic Sapphire Oscillator using a low-vibration design pulse-tube cryocooler: First results

    CERN Document Server

    Hartnett, John G; Wang, Chao; Floch, Jean-Michel Le

    2010-01-01

    A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their combined fractional frequency instability is $\\sigma_y = 1.4 \\times 10^{-15}\\tau^{-1/2}$ for integration times $1 < \\tau < 10$ s, dominated by white frequency noise. The minimum $\\sigma_y = 5.3 \\times 10^{-16}$ for the two oscillators was reached at $\\tau = 20$ s. Assuming equal contributions from both CSOs, the single oscillator phase noise $S_{\\phi} \\approx -96 \\; dB \\; rad^2/Hz$ at 1 Hz offset from the carrier.

  16. Single-pulse shock tube pyrolysis of toluene and 1,3-butadiene

    Science.gov (United States)

    Colket, M. B.

    1983-01-01

    The objective of this research is to investigate the rate limiting chemical mechanisms leading to the formation of soot precursors. A single-pulse shock tube is being used to collect gas samples of stable intermediates and end products of hydrocarbon pyrolysis. These gas samples are analyzed quantitatively using gas chromatography and any mass imbalance is believed to be due to the formation of PAH's and soot. Experimental decomposition rates of the parent hydrocarbon are determined and compared to predictions from the literature. Detailed chemical kinetic mechanisms describing hydrocarbon pyrolysis are being developed and models of soot formation are being compared with the experimental results. Information developed from these pyrolysis studies will provide the fundamental understanding for modeling subsequent oxidation experiments.

  17. Investigation of gravitational effects in pulse tube cryocoolers using 3-D CFD

    Science.gov (United States)

    Mulcahey, T. I.; Conrad, T. J.; Ghiaasiaan, S. M.; Pathak, M. G.

    2014-01-01

    Stirling-type pulse tube cryocoolers (PTC) are often selected for cryogenic cooling applications for their robustness and mechanical simplicity, having no moving parts at the cold end of the cooler. Originally designed for space applications, increased terrestrial use in tactical applications as well as ground testing of space systems has revealed that some PTCs exhibit sensitivity to gravitational orientation, often losing significant cooling performance unless situated with the cold end pointing downward. Previous investigations have indicated that some coolers exhibit sensitivity while others do not; however, a reliable method of predicting the level of sensitivity during the design process has not been developed. We have utilized 3-D computational fluid dynamics (CFD) to predict the percent of cooling capacity lost as a result of off-axis operation. The computational model has been validated experimentally on a number of coolers to enhance confidence in the method used.

  18. Loss Analysis of High Power Stirling-Type Pulse Tube Cryocooler

    Science.gov (United States)

    Nakano, K.; Hiratsuka, Y.

    2015-12-01

    For the purpose of cooling high-temperature superconductor (HTS) devices, such as superconductor motors, superconducting magnetic energy storage (SMES) and current fault limiters, cryocoolers should be compact in size, light-weight, and have high efficiency and reliability. In order to meet the demand of HTS devices world-wide, the cryocooler needs to have COP efficiency >0.1. We have developed a high power Stirling-type pulse tube cryocooler (SPTC) with an in-line expander. The experimental results were reported in June 2012[1]. The cooling capacity was 210 W at 77 K and the minimum temperature was 37 K when the compressor input power was 3.8 kW. Accordingly, the COP was about 0.055. To further improve the efficiency, the energy losses in the cryocooler were analyzed. The experimental results and the numerical calculation results are reported in this paper.

  19. Development of a miniature coaxial pulse tube cryocooler for a space-borne infrared detector system

    Science.gov (United States)

    Dang, H. Z.; Wang, L. B.; Wu, Y. N.; Yang, K. X.; Shen, W. B.

    2010-04-01

    A single-stage miniature coaxial pulse tube cryocooler prototype is developed to provide reliable low-noise cooling for an infrared detector system to be equipped in the future space mission. The challenging work is the exacting requirement on its dimensions due to the given miniature Dewar. The limited dimensions result in the insufficiency of the phaseshifting ability of the system when inertance tubes alone are employed. A larger filling pressure of 3.5 Mpa and higher operating frequency up to 70 Hz are adopted to increase the energy density, which compensates for the decrease in working gas volume due to the miniature structure, and realize a fast cool down process. A 1.5 kg dual opposed linear compressor based on flexure bearing and moving magnet technology is used to realize light weight, high efficiency and low contamination. The design and optimization are based on the theoretical CFD model developed by the analyses of thermodynamic behaviors of gas parcels in the oscillating flow. This paper describes the design approach and trade-offs. The cooler performance and characteristics are presented.

  20. 1 K cryostat with sub-millikelvin stability based on a pulse-tube cryocooler

    Science.gov (United States)

    DeMann, A.; Mueller, Sara; Field, S. B.

    2016-01-01

    A cryogenic system has been designed and tested that reaches a temperature below 1.1 K, with an rms temperature stability of 25 μ K. In this system a commercial pulse-tube cryocooler is used to liquify helium gas supplied from an external source. This liquid helium enters a 1 K pot through a large-impedance capillary tube, similar to a conventional 1 K system operated from a liquid helium bath. Unlike a conventional system, however, the molar flow rate of the system can be varied by changing the pressure of the incoming helium. This allows for a trade-off between helium usage and cooling power, which has a maximum value of 27 mW. The measured cooling power and fraction of helium exiting the capillary as liquid agree well with predictions based on an isenthalpic model of helium flow through the capillary. The system is simple to use and inexpensive to operate: The system can be cooled to base temperature in about 3 h and, with a flow rate giving a cooling power of 13 mW, the helium cost is around 6 per day.

  1. Commercialisation of Pulse Tube cryocoolers to produce 330 W and 1000 W at 77 K for liquefaction

    Science.gov (United States)

    Caughley, A.; Emery, N.; Nation, M.; Allpress, N.; Kimber, A.; Branje, P.; Reynolds, H.; Boyle, C.; Meier, J.; Tanchon, J.

    2015-12-01

    Fabrum Solutions in collaboration with Callaghan Innovation has been developing large pulse tube cryocoolers based on Callaghan Innovation's diaphragm pressure wave generators (DPWG). The pulse tube's lack of moving parts in combination with the DPWG's metal diaphragms produces a cost-effective, long life and robust cryocooler. The DPWG has had 10 years of development, resulting in a series of DPWGs ranging in input powers from 0.5 kW to 30 kW that have been coupled to a variety of in-line and coaxial pulse tubes. Two DPWGs have had in excess of 7000 hours running to date. The PTC330 cryocooler is based on a new 330 cc DPWG and has produced 480 W of cooling at 77 K during testing. The PTC1000 combines three such pulse tubes on a single 1000 cc DPWG to produce 1270 W at 77 K. This paper details the development of the PTC330 and PTC1000 cryocoolers from initial lab prototypes through to commercial products, integrated into liquefiers and ready for use in applications such as: Nitrogen liquefaction, re-liquefaction of boil-off from storage tanks, or cooling of cryostats for High Temperature Superconductor applications.

  2. Cryogen-free dilution refrigerator with separate 1K cooling circuit.

    Science.gov (United States)

    Uhlig, Kurt

    2012-06-01

    Helium-3,4 dilution refrigeration is indispensable for low temperature science and engineering as it is the only method which provides temperatures between 0.3 K and 0.005 K for unlimited working periods. Cryogen-free dilution refrigerators are about to replace traditional cryostats with liquid helium precooling. The dilution circuit is always precooled by a two-stage pulse tube cryocooler; therefore, refrigeration capacities are available to the experimentalist at the temperatures of the two stages of the pulse tube cooler, and furthermore at three temperatures of the dilution circuit (~ 0.7 K - still, 0.1 K - heat exchanger, ~ 0.01 K - mixing chamber). However, there are quite a few applications (e.g. quantum information processing or astro-physics) where the cooling power of the still near ~ 1K is not sufficient to cool amplifiers and electric lines. In our work we present a dilution refrigerator where a He-4 cooling circuit has been added in the cryostat to the dilution circuit. This He-4 circuit provides up to 60 mW of refrigeration capacity in addition to the cooling capacity of ~ 30 mW of the still. The dilution circuit and the 1Kcircuit can be operated together or separately.

  3. A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T. W.; Babbar, V. K.; Underhill, P. R. [Department of Physics, Royal Military College of Canada, Kingston, ON (Canada)

    2014-02-18

    Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators.

  4. A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

    Science.gov (United States)

    Krause, T. W.; Babbar, V. K.; Underhill, P. R.

    2014-02-01

    Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators.

  5. Theoretical and experimental investigations on the dynamic and thermodynamic characteristics of the linear compressor for the pulse tube cryocooler

    Science.gov (United States)

    Zhang, L.; Dang, H. Z.; Tan, J.; Bao, D.; Zhao, Y. B.; Qian, G. Z.

    2015-12-01

    Theoretical and experimental investigations on the dynamic and thermodynamic characteristics of a linear compressor incorporating the thermodynamic characteristics of the inertance tube pulse tube cold finger have been made. Both the compressor and cold finger are assumed as a one-dimensional thermodynamic model. The governing equations of the thermodynamic characteristics of the working gas are summarized, and the effects of the cooling performance on the working gas in the compression space are discussed. Based on the analysis of the working gas, the governing equations of the dynamic and thermodynamic characteristics of the compressor are deduced, and then the principles of achieving the optimal performance of the compressor are discussed in detail. Systematic experimental investigations are conducted on a developed moving-coil linear compressor which drives a pulse tube cold finger, which indicate the general agreement with the simulated results, and thus verify the rationality of the theoretical model and analyses.

  6. Performance Prediction and Experimental Investigations on Integral Pulse Tube Cryocooler for 15 W at 70 K Using Indigenously Developed Linear Compressor

    Science.gov (United States)

    Gawali, B. S.; Narayankhedkar, K. G.

    2006-04-01

    Theoretical model based on cyclic analysis has been extended to design the integral pulse tube cryocooler. Cryocooler is developed to match with the indigenously developed opposed piston linear compressor of 30 cc swept volume. The design is carried for the Stirling type Pulse Tube cryocooler to develop 15 W at 70 K. The Pulse Tube cryocooler has been developed with due attention to the heat exchangers and regenerator. Experimental investigations have been carried out for study of the effect of pulse tube aspect ratio and to confirm the consistency of the model and suitability of the linear compressor. Experimental investigation confirmed consistent performance of the linear compressor as well as the Pulse Tube cryocooler.

  7. Malone refrigeration

    Science.gov (United States)

    Swift, G. W.

    Malone refrigeration is the use of a liquid near its critical point, without evaporation, as the working fluid in a refrigeration cycle such as the Stirling cycle. We discuss relevant properties of appropriate liquids, and we describe two Malone refrigerators. The first, which was completed several years ago, established the basic principles of use for liquids in such cycles. The second, now under construction, is a linear, free-piston machine.

  8. Design and experiment on unit tube used for adsorption refrigeration systems in ships%一种用于船舶吸附制冷系统的单元管设计与实验

    Institute of Scientific and Technical Information of China (English)

    朱成剑; 武卫东

    2012-01-01

    基于前人提出的利用船舶内燃机排气废热的吸附式制冷系统系统的设计思想,文中致力于应用在吸附床中的单元冷管的研究,进行了一种用于船舶吸附式制冷系统的单元冷管的结构设计、工质对选择等,并实验分析和研究了添加可膨胀石墨的吸附单元冷管的循环特性,文中研究为今后的单元和系统设计提供了一定的实践指导.%Based on the design of adsorption refrigeration systems using engine exhaust heat in ships proposed by predecessors, this article focused on the research on unit cooling tube applied in adsorption bed, conducted structure design and working medium pair selection for unit cooling tube used for adsorption refrigeration systems in ships, and experimentally analyzed and studies the cycle characteristics of the adsorption unit cooling tube with expandable graphite. The research can provide some practical guidance for future unil and system design.

  9. DKV joint project: reduction of CFC-emissions in air conditioning and refrigeration. Subproject 6. Pool boiling of new refrigerants and their mixtures at single plain and finned tubes. Final report; DKV-Verbundvorhaben: Minderung von FCKW-Emissionen in der Klima- und Kaeltetechnik. Teilvorhaben 6; Waermeuebergang bei der Verdampfung neuer Kaeltemittel an einzelnen Glatt- und Rippenrohren. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Gorenflo, D.; Rott, W.; Sokol, P.; Caplanis, S; Kuenstler, W.

    1993-03-01

    Heat transfer at pool boiling from three novel finned tubes with different fin geometry to the new refrigerants R134a (CH{sub 2}F.CF{sub 3}), R152a (CH{sub 3}.CHF{sub 2}), R227 (CF{sub 3}.CHF.CF{sub 3}) and to a nearly equimolar mixture of R134a and R152a has been investigated within extended ranges of heat flux and saturation pressure. The main new features of the tubes are: K-shaped fins with very narrow fin distances/T-shaped fins with additional grooves between the fins/Y-shaped fins with additional grooves between the fins. The results show that especially the tubes with T-shaped and Y-shaped fins are significantly superior to plain tubes at pool boiling of the new refrigerants at saturation pressures up to approximately 10 bar. The biggest enhancement has been achieved using the tube with Y-shaped fins, thus energy consumption can be reduced by smaller temperature differences on the pool side, if these tubes will be applied, and the amount of refrigerants as well as construction material for the evaporators can be reduced by more compact design, being possible, because the heat flow rate transferred per unit of tube length may be chosen higher. (orig.). 11 refs., 1 tab., 12 figs. [Deutsch] Durch Waermeuebergangsmessungen bei der Verdampfung von neuen, teilfluorierten Kaeltemitteln an neuentwickelten Hochleistungs-Verdampferrohren sollten verlaessliche Auslegungsgrundlagen fuer optimierte Rohrbuendelverdampfer bereitgestellt werden, die mit geringerem Energiebedarf und durch kompakte Bauweise mit reduziertem Material- und Kaeltemittelaufwand auskommen und dadurch einerseits kein Ozongefaehrdungspotential und andererseits einen geringeren Beitrag zum Treibhauseffket liefern als die z.Zt. noch verwendete Technik. Zu Beginn des Vorhabens existierten entsprechende Unterlagen in der Literatur nicht. Als Versuchsstoffe dienten die neuen Kaeltemittel R134a(CH{sub 2}F.CF{sub 3}), R152a(CH{sub 3}.CHF{sub 2}), R227(CF{sub 3}.CHF.CF{sub 3}) sowie ein etwa aequimolares

  10. Refrigerator-freezer energy testing with alternative refrigerants

    Science.gov (United States)

    Vineyard, E. A.; Sand, J. R.; Miller, W. A.

    1989-07-01

    As a result of the Montreal Protocol that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must be resolved. Among these are energy impacts, system compatibility, cost, and availability. In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers. The results are presented for an 18 cubic foot (0.51 cubic meter), top-mount refrigerator-freezer with a static condenser using the following refrigerants: R12, R500, R12/Dimethyl-ether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12 /DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants indicating a higher capacity. While the R134a and R22/R142b results were less promising, changes to the refrigeration system, such as a different capillary tube or compressor, may improve performance.

  11. 386 mW/20 K single-stage Stirling-type pulse tube cryocooler

    Science.gov (United States)

    Chen, Liubiao; Zhou, Qiang; Jin, Hai; Zhu, Wenxiu; Wang, Junjie; Zhou, Yuan

    2013-10-01

    Recently, we reported a single-stage Stirling-type pulse tube cryocooler (SPTC) that achieved a no-load temperature of 18.6 K and 0.2 W/20.6 K with 268 W input power at the frequency of 38 Hz. By further optimizing the regenerator, using the stainless steel screens only, a new SPTC driven by a dual-opposed linear compressor has been built and tested. At present, a lowest temperature of 15.5 K, which is a new record for single-stage SPTC, and 386 mW/20 K cooling power can be achieved with 246 W input power, which is comparable to the two-stage SPTC with a similar input power. The optimization process of regenerator will be presented in this paper. Experimental results indicate that it is important for SPTC to reduce the flow resistance of regenerator at the warm end and enhance the regenerative capacity of the cold end to improve the cooling performance. Lead spheres were also employed as part of the regenerator to achieve the possible lower temperature, but the test results show that there is no evident improvement in achieving lower temperature.

  12. CFD simulation of a miniature coaxial Stirling-type pulse tube cryocooler operating at 128 Hz

    Science.gov (United States)

    Zhao, Yibo; Dang, Haizheng

    2016-01-01

    A two-dimensional axis-symmetric CFD model of a miniature coaxial Stirling-type pulse tube cryocooler with an overall weight of 920 g operating at 128 Hz is established, and systematic simulations of the performance characteristics at different temperatures are conducted. Both thermal equilibrium and non-equilibrium mechanisms for the porous matrix are considered, and the regenerator losses including the gas and solid conduction, the pressure drop and the imperfect interfacial heat transfer are calculated, respectively. The results indicate that the pressure drop loss is dominant during the first 85% and 78% of regenerator length for the thermal equilibrium and non-equilibrium models, respectively, and it decreases monotonously from warm to cold end due to the steadily decreasing Darcy and Forchheimer terms, whereas other entropy generations share similar changing tendencies, going up gradually near the warm end, increasing dramatically from about 60% of length and then decreasing sharply near the cold end. The reasons for these entropy variations are discussed.

  13. Atomic fountain clock with very high frequency stability employing a pulse-tube-cryocooled sapphire oscillator.

    Science.gov (United States)

    Takamizawa, Akifumi; Yanagimachi, Shinya; Tanabe, Takehiko; Hagimoto, Ken; Hirano, Iku; Watabe, Ken-ichi; Ikegami, Takeshi; Hartnett, John G

    2014-09-01

    The frequency stability of an atomic fountain clock was significantly improved by employing an ultra-stable local oscillator and increasing the number of atoms detected after the Ramsey interrogation, resulting in a measured Allan deviation of 8.3 × 10(-14)τ(-1/2)). A cryogenic sapphire oscillator using an ultra-low-vibration pulse-tube cryocooler and cryostat, without the need for refilling with liquid helium, was applied as a local oscillator and a frequency reference. High atom number was achieved by the high power of the cooling laser beams and optical pumping to the Zeeman sublevel m(F) = 0 employed for a frequency measurement, although vapor-loaded optical molasses with the simple (001) configuration was used for the atomic fountain clock. The resulting stability is not limited by the Dick effect as it is when a BVA quartz oscillator is used as the local oscillator. The stability reached the quantum projection noise limit to within 11%. Using a combination of a cryocooled sapphire oscillator and techniques to enhance the atom number, the frequency stability of any atomic fountain clock, already established as primary frequency standard, may be improved without opening its vacuum chamber.

  14. Operating characteristics of a three-stage Stirling pulse tube cryocooler operating around 5 K

    Science.gov (United States)

    Qiu, L. M.; Cao, Q.; Zhi, X. Q.; Han, L.; Gan, Z. H.; Yu, Y. B.; Liu, Y.; Zhang, X. J.; Pfotenhauer, J. M.

    2012-07-01

    A Stirling pulse tube cryocooler (SPTC) operating at the liquid-helium temperatures represents an excellent prospect for satisfying the requirements of space applications because of its compactness, high efficiency and reliability. However, the working mechanism of a 4 K SPTC is more complicated than that of the Gifford McMahon (GM) PTC that operates at the relatively low frequency of 1-2 Hz, and has not yet been well understood. In this study, the primary operating parameters, including frequency, charge pressure, input power and precooling temperature, are systematically investigated in a home-developed separate three-stage SPTC. The investigation demonstrates that the frequency and precooling temperature are closely coupled via phase shift. In order to improve the cooling capacity it is important to lower the frequency and the precooling temperature simultaneously. In contrast to the behavior predicted by previous studies, the pressure dependence of the gas properties results in an optimized pressure that decreases significantly as the temperature is lowered. The third stage reaches a lowest temperature of 4.97 K at 29.9 Hz and 0.91 MPa. A cooling power of 25 mW is measured at 6.0 K. The precooling temperature is 23.7 K and the input power is 100 W.

  15. A high-temperature superconducting millimeter wave detecting system based on pulse tube cryocooler

    Science.gov (United States)

    Chen, Jian; Wu, Peiheng; Nakajima, Kensuke; Yamashita, Tsutomu

    2004-10-01

    A millimeter (mm) wave broadband video detecting system using high temperature superconducting (HTS) junction and compact pulse tube cryocooler (PTC) has been studied. The lowest attainable temperature of the PTC is 42K and the operating temperature (T) can be adjusted by changing the pressure difference in the compressor. By measuring the linewidth of the Josephson oscillation as well as the dynamic range of the Josephson detector, it is found that the PTC has no excess noise compared with other kinds of cryostats such as liquid helium cryostats, and is very suitable for the applications in the mm wave detecting system. Furthermore, to improve the sensitivity of the system, the coupling efficiency of the system has been studied in detail. It is found that the coupling efficiency increases with the increase of RN linearly, and is better than 1% for RN of 1.7 Ohm. A sensitivity of about 318V/W has been obtained for the system based on the PTC and a junction with RN=1.7 Ohm and ICRN =1mV.

  16. Isomerization of cis-1,2-dimethylcyclohexane in single-pulse shock tube experiments.

    Science.gov (United States)

    Rosado-Reyes, Claudette M; Tsang, Wing

    2014-09-11

    Cyclic hydrocarbons are major constituents of jet fuels and reference compounds in jet fuel surrogates. The kinetic and thermal stability and reaction mechanisms of fuel molecules are essential input parameters in the models and simulations used in the design of novel fuels, renewable energy technologies, and devices. A detailed study and analysis of the pyrolytic chemistry of cis-1,2-dimethylcyclohexane has been performed in single-pulse shock tube experiments. The investigations are carried out over the temperature range of 1100 to 1200 K at about 2.5 atm pressure. The isomeric products are trans-1,2-dimethylcyclohexane, 1-octene, and (cis + trans)-2-octene. The three octene isomers can be attributed to internal disproportionation processes. Assuming a diradical mechanism and that cis-1,2-dimethylcyclohexane is formed in equal amount with respect to its trans isomer, the total rate expression for isomerization is kC-C = 10(15.5±0.8) exp(-38,644 ± 2061 K/T) s(-1). The rate constants are over an order of magnitude smaller than the equivalent noncyclic hydrocarbon system. The presence of the isomeric octenes suggests that internal disproportionation is an important component of the isomerization process.

  17. Thermal decomposition of propargyl alcohol: single pulse shock tube experimental and ab initio theoretical study.

    Science.gov (United States)

    Sharath, N; Reddy, K P J; Arunan, E

    2014-08-07

    Thermal decomposition of propargyl alcohol (C3H3OH), a molecule of interest in interstellar chemistry and combustion, was investigated using a single pulse shock tube in the temperature ranging from 953 to 1262 K. The products identified include acetylene, propyne, vinylacetylene, propynal, propenal, and benzene. The experimentally observed overall rate constant for thermal decomposition of propargyl alcohol was found to be k = 10((10.17 ± 0.36)) exp(-(39.70 ± 1.83)/RT) s(-1). Ab initio theoretical calculations were carried out to understand the potential energy surfaces involved in the primary and secondary steps of propargyl alcohol thermal decomposition. Transition state theory was used to predict the rate constants, which were then used and refined in a kinetic simulation of the product profile. The first step in the decomposition is C-O bond dissociation, leading to the formation of two important radicals in combustion, OH and propargyl. This has been used to study the reverse OH + propargyl radical reaction, about which there appears to be no prior work. Depending on the site of attack, this reaction leads to propargyl alcohol or propenal, one of the major products at temperatures below 1200 K. A detailed mechanism has been derived to explain all the observed products.

  18. In-situ formation of solidified hydrogen thin-membrane targets using a pulse tube cryocooler

    Science.gov (United States)

    Astbury, S.; Bedacht, S.; Brummitt, P.; Carroll, D.; Clarke, R.; Crisp, S.; Hernandez-Gomez, C.; Holligan, P.; Hook, S.; Merchan, J. S.; Neely, D.; Ortner, A.; Rathbone, D.; Rice, P.; Schaumann, G.; Scott, G.; Spindloe, C.; Spurdle, S.; Tebartz, A.; Tomlinson, S.; Wagner, F.; Borghesi, M.; Roth, M.; Tolley, M. K.

    2016-04-01

    An account is given of the Central Laser Facility's work to produce a cryogenic hydrogen targetry system using a pulse tube cryocooler. Due to the increasing demand for low Z thin laser targets, CLF (in collaboration with TUD) have been developing a system which allows the production of solid hydrogen membranes by engineering a design which can achieve this remotely; enabling the gas injection, condensation and solidification of hydrogen without compromising the vacuum of the target chamber. A dynamic sealing mechanism was integrated which allows targets to be grown and then remotely exposed to open vacuum for laser interaction. Further research was conducted on the survivability of the cryogenic targets which concluded that a warm gas effect causes temperature spiking when exposing the solidified hydrogen to the outer vacuum. This effect was shown to be mitigated by improving the pumping capacity of the environment and reducing the minimum temperature obtainable on the target mount. This was achieved by developing a two-stage radiation shield encased with superinsulating blanketing; reducing the base temperature from 14 ± 0.5 K to 7.2 ± 0.2 K about the coldhead as well as improving temperature control stability following the installation of a high-performance temperature controller and sensor apparatus. The system was delivered experimentally and in July 2014 the first laser shots were taken upon hydrogen targets in the Vulcan TAP facility.

  19. Design, analyses, fabrication and characterization of Nb3Sn coil in 1 W pulse tube cryocooler

    Science.gov (United States)

    Kundu, Ananya; Das, Subrat Kumar; Bano, Anees; Kumar, Nitish; Pradhan, Subrata

    2017-02-01

    A laboratory scale Nb3Sn coil is designed, analysed, fabricated and characterized in 1 W pulse tube cryocooler in solid nitrogen cooling mode and in conduction cooling mode. The magnetic field profile in axial and radial direction, Lorentz force component across the winding volume in operational condition are estimated in COMSOL. The coil is designed for 1.5 T at 100 A. It is fabricated in wind and react method. Before winding, the insulated Nb3Sn strand is wound on a copper mandrel which is thermally anchored with the 2nd stage of the cold head unit via a 10 mm thick copper ‘Z’ shaped plate The temperature distribution in 2nd cold stage, copper z plate and coil is monitored in both solid nitrogen cooling and conduction cooling mode. In solid nitrogen cooling mode, the quench of the coil occurs at 150 A for 0.01 A/s current ramp rate. The magnetic field at the centre of the coil bore is measured using transverse Hall sensor. The measured magnetic field value is compared with the analytical field value and they are found to be deviating ∼5% in magnitude. Again the coil is tested in conduction cooling mode maintaining the same current ramp rate and it is observed that the coil gets quenched at 70 A at temperature ∼ 10K.

  20. A closed-cycle 1 K refrigeration cryostat

    Science.gov (United States)

    Wang, Chao; Lichtenwalter, Ben; Friebel, Aaron; Tang, Hong X.

    2014-11-01

    A 1 K closed-cycle cryostat has been developed to provide continuous cooling to a photon detector below 2 K. A two-stage 4 K pulse tube cryocooler is used to liquefy evacuated vapor from a 1 K pumping port to form a closed-cycle refrigeration loop. A 1 K instrumentation chamber, attached to the 1 K cooling station, is designed to operate with helium inside and provide more uniform cooling. The design of the cryostat has no direct mechanical contact between the pulse tube cryocooler heat exchangers and the 1 K cooling station resulting in almost no vibration transfer to instrumentation chamber. The cryostat can reach a no-load temperature of 1.62 K and provide 250 mW cooling power at 1.84 K.

  1. Analysis of refrigerant mal-distribution

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Elmegaard, Brian

    2009-01-01

    to be two straight tubes. The refrigerant maldistribution is then induced to the evaporator by varying the vapor quality at the inlet to each tube and the air-flow across each tube. Finally it is shown that mal-distribution can be compensated by an intelligent distributor, that ensures equal superheat...

  2. Phase-locked oscillator at 3 mm waveband using high Tc superconductor mixer mounted on pulse tube crycooler

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A frequency mixing and phase locking system is designed, in which electromagnetic shielding, microwave coupling, and intermediate frequency (IF) measurement arrangements are included. In lieu of liquid nitrogen, a pulse tube cryocooler is used to cool the whole system. With Josephson grain boundary junction as the mixing element, the 96th harmonic frequency mixing at 3 mm waveband is obtained, and phase-locked voltage- controlled oscillator (VCO) is realized.

  3. Experimental Studies on a Single Stage Stirling Type Pulse Tube Cryocooler Driven by Oil-Lubricated Compressor

    Science.gov (United States)

    Jia, Ren; Jianying, Hu; Ercang, Luo; Xiaotao, Wang

    2010-04-01

    Because lubricating oil for moving parts is not allowed to go into the pulse tube cryocooler, Stirling type pulse tube cryocoolers are generally driven by oil-free compressors although oil-lubricated compressors are much cheaper and facile. Recently, it was proposed that an acoustic transparent and oil blocking diaphragm could be employed to separate the compressor and the cryocooler. Thus, the cryocooler can be driven by oil-lubricated compressors. In this paper, a pulse tube cryocooler is designed to match a crankcase compressor. Although the efficiency of the crankcase compressor is lower compared with the oil-free linear compressor, the crankcase compressor can easily work at lower frequency which results in higher efficiency for the cryocooler. So the relative high performance of the whole system can be maintained. In this system, the cryocooler delivers 28.5 W of cooling at 80 K with 680 W of electrical input power and operates at 15 Hz. The corresponding Carnot efficiency is 11.52%.

  4. Deposition of hard and adherent diamond-like carbon films inside steel tubes using a pulsed-DC discharge.

    Science.gov (United States)

    Trava-Airoldi, Vladimir Jesus; Capote, Gil; Bonetti, Luís Francisco; Fernandes, Jesum; Blando, Eduardo; Hübler, Roberto; Radi, Polyana Alves; Santos, Lúcia Vieira; Corat, Evaldo José

    2009-06-01

    A new, low cost, pulsed-DC plasma-enhanced chemical vapor deposition system that uses a bipolar, pulsed power supply was designed and tested to evaluate its capacity to produce quality diamond-like carbon films on the inner surface of steel tubes. The main focus of the study was to attain films with low friction coefficients, low total stress, a high degree of hardness, and very good adherence to the inner surface of long metallic tubes at a reasonable growth rate. In order to enhance the diamond-like carbon coating adhesion to metallic surfaces, four steps were used: (1) argon ion sputtering; (2) plasma nitriding; (3) a thin amorphous silicon interlayer deposition, using silane as the precursor gas; and (4) diamond-like carbon film deposition using methane atmosphere. This paper presents various test results as functions of the methane gas pressure and of the coaxial metal anode diameter, where the pulsed-DC voltage constant is kept constant. The influence of the coaxial metal anode diameter and of the methane gas pressure is also demonstrated. The results obtained showed the possibilities of using these DLC coatings for reduced friction and to harden inner surface of the steel tubes.

  5. 制冷装置用管壳式换热器清洁度管控研究%The Research of Management and Control the Cleanliness of Shell-and-tube Heat-exchanger Used in Refrigeration Equipment

    Institute of Scientific and Technical Information of China (English)

    周艳彬; 王少军; 杨久子

    2014-01-01

    This paper describes the importance of cleanliness to refrigeration equipment of central air-conditioning. Aiming at the shell-and-tube heat exchanger, it analyzes the pollution resource, and mainly discusses the control method and measurement of the cleanliness level from the perspectives of the design structure, the parts processing, and the shell-and-tube heat exchanger process.%本文讲述了清洁度对于中央空调制冷主机的重要性。针对管壳式换热器,分析了污染杂质来源,并从设计结构、零部件加工和管壳式换热器总成工艺三方面重点讨论其清洁度控制方法和措施。

  6. Incident shock wave attenuation in oscillatory tube and influence on performance of pressure wave refrigerator%振荡管内入射激波衰减及其对冷效应的影响

    Institute of Scientific and Technical Information of China (English)

    郑闽锋; 刘曦; 黄成; 林跃东; 雷晓健; 李学来

    2014-01-01

    The pressure wave refrigerator represents a simple arrangement for gas cooling by its decompression and has many applications in chemical processes and energy transformation. The mechanism of the cooling effect of oscillatory tube is the conversion of the pressure energy of gas to heat through the movement of pressure waves, which are moving shock wave and unsteady expansion wave. In the present paper, the regular pattern of incident shock wave attenuation and its influence on the performance of pressure wave refrigerator are investigated by means of a single-tube set up. In the experiments, the expansion ratio is from 2.0 to 6.0, the relative length of the oscillatory tube L/d is from 87 to 737, and the exciting frequency is from 10 Hz to 240 Hz. The experimental results show that the relative strength of incident shock wave is reduced with the increase of relative position in length x/L because the energy of the reflected shock wave is exhausted by the viscosity and friction of the gas inside the tube. The other reason is the result of the gas in the tube pressurized and heated by the shock wave. The shock wave strength is also influenced by transmission and reflection effects resulted from the reflected shock wave. When the tube is relatively short, the relative strength of incident shock wave is less reduced as the tube length decreases, while the strength of the reflected shock wave at the closed end of the tube increases. The maximum refrigeration efficiencyηmax of the refrigerator increases with the tube length, but the value ofηmax is not affected obviously when the tube length increases to some value. The recommended optimal tube length L/d is 300-435 for the tube in this experiment. It helps to improve the performance of the pressure wave refrigerator under variable work condition when the amplitude of the refrigeration efficiency fluctuation is reduced as the length increases. The relative strength of the incident shock wave attenuation is concerned

  7. Experiment Study and Application Analysis of Adsorption Refrigeration 0 f Solar Cooling Tube%新型太阳能冷管吸附制冷的实验研究

    Institute of Scientific and Technical Information of China (English)

    王彦禹; 倪诚明

    2015-01-01

    根据固体吸附式制冷原理,利用太阳光作为热源,对一种新型太阳能冷管的制冷性能进行试验研究。该冷管冷凝器采用薄壁不锈钢材料,利用沸石分子筛—水作为吸附工质对。实验结果表明:在太阳辐射强度为21.01~22.90MJ/m2,室外环境温度最高为31℃时,该太阳能冷管的单支制冷量大约为145kJ,制冷温度为11℃,制冷系数约为0.118。%According to the principle of the solid adsorption refrigeration, a new type of solar cooling tube, which used the sun light as a heat source and zeolite molecular sieve/water as working pair, was made and studied in this research.The condenser was made of thin-wall stainless steel materials.The experiment results showed that: When the solar radiation intensity was between 21.01-22.90MJ/m2 and the highest environment temperature was 31℃, refrigeration capacity of the single cooling tube was 145kJ.Besides its condensation temperature was about 11℃and the refrigeration coefficient was about 0.118.

  8. Superfluid Stirling refrigerator: A new method for cooling below 1 Kelvin

    Science.gov (United States)

    Kotsubo, V.; Swift, G. W.

    We have invented and built a new type of cryocooler, which we call the superfluid Stirling refrigerator (SSR). The first prototype reached 0.6 K from a starting temperature of 1.2 K. The working fluid of the SSR is the (sup 3)He solute in a superfluid He(3) - He(4) solution. At low temperatures, the superfluid He(4) is in its quantum ground state, and therefore is thermodynamically inert, while the He(3) solute has the thermodynamic properties of a dense ideal gas. Thus, in principle, any refrigeration cycle that can use an ideal gas can also use the He(3) solute as working fluid. In our SSR prototype, bellows-sealed superleak pistons driven by a room-temperature camshaft work on the He(3) solute. Ultimately, we anticipate elimination of moving parts by analogy with pulse-tube refrigeration.

  9. Steady Secondary Flows Generated by Periodic Compression and Expansion of an Ideal Gas in a Pulse Tube

    Science.gov (United States)

    Lee, Jeffrey M.

    1999-01-01

    This study establishes a consistent set of differential equations for use in describing the steady secondary flows generated by periodic compression and expansion of an ideal gas in pulse tubes. Also considered is heat transfer between the gas and the tube wall of finite thickness. A small-amplitude series expansion solution in the inverse Strouhal number is proposed for the two-dimensional axisymmetric mass, momentum and energy equations. The anelastic approach applies when shock and acoustic energies are small compared with the energy needed to compress and expand the gas. An analytic solution to the ordered series is obtained in the strong temperature limit where the zeroth-order temperature is constant. The solution shows steady velocities increase linearly for small Valensi number and can be of order I for large Valensi number. A conversion of steady work flow to heat flow occurs whenever temperature, velocity or phase angle gradients are present. Steady enthalpy flow is reduced by heat transfer and is scaled by the Prandtl times Valensi numbers. Particle velocities from a smoke-wire experiment were compared with predictions for the basic and orifice pulse tube configurations. The theory accurately predicted the observed steady streaming.

  10. Autonomous cryogenic sapphire oscillators employing low vibration pulse-tube cryocoolers at NMIJ

    Science.gov (United States)

    Ikegami, Takeshi; Watabe, Ken-ichi; Yanagimachi, Shinya; Takamizawa, Akifumi; Hartnett, John G.

    2016-06-01

    Two liquid-helium-cooled cryogenic sapphire-resonator oscillators (CSOs), have been modified to operate using cryo-refrigerators and low-vibration cryostats. The Allan deviation of the first CSO was evaluated to be better than 2 x 10-15 for averaging times of 1 s to 30 000 s, which is better than that of the original liquid helium cooled CSO. The Allan deviation of the second CSO is better than 4 x 10-15 from 1 s to 6 000 s averaging time.

  11. Simulation on the Performance of Adiabatic Capillary Tube in CO2 Transcritical Refrigeration System%跨临界CO2制冷系统中绝热毛细管性能模拟研究

    Institute of Scientific and Technical Information of China (English)

    王晶; 赵远扬; 李连生; 王智忠

    2011-01-01

    建立了CO2制冷系统中绝热毛细管一维稳态分布参数模型,以研究跨临界CO2系统中毛细管的性能和流动特性.分别采用3种不同摩擦系数关联式(Churchill、Colebrook、Bittle&Pate关联式)进行模拟和比较,研究了CO2在毛细管内的温度、压力、焓、熵及干度等的沿程分布规律.分析了管径、入口压力、入口温度和背压等4个参数对毛细管质量流量的影响,并考虑了壅塞现象.结果表明:采用Churchill和Colebrook关联式的效果较好,92%的计算值误差在10%以内,而Bittle&Pate关联式不适用于CO2绝热毛细管计算,因为它未考虑毛细管内壁的粗糙度;背压对质量流量影响很小,即使发生壅塞,壅塞质量流量和未壅塞时的质量流量差别也不大.%A one dimension homogeneous steady model of adiabatic capillary tubes in CO2 tran-scritical refrigeration systems was established to evaluate the performance and the flow characteristics of capillary tubes. The simulation results by using three different friction factor correlations (Churchill, Colebrook, Bittle&Pate) were compared with each other. The distributions of temperature, pressure, enthalpy and entropy along the tube length were investigated. The influences of four parameters (inner diameter, inlet pressure, inlet temperature, back pressure) on the mass flow rate were explored, and the chocking phenomenon was analyzed. The results show that the Churchill correlation and the Colebrook correlation predict 92% of the refrigerant mass flow rates with an error of less than 10% while the Bittle&Pate correlation may be unsuitable for simulating the flow in CO2 capillary tubes due to its neglect of the inner wall roughness of capillary tubes. The back pressure has slight influence on the mass flow rate. In addition, the rate of mass flow without chocking is approximately equal to that with chocking.

  12. Multi-stage pulse tube cryocooler with acoustic impedance constructed to reduce transient cool down time and thermal loss

    Science.gov (United States)

    Gedeon, David R. (Inventor); Wilson, Kyle B. (Inventor)

    2008-01-01

    The cool down time for a multi-stage, pulse tube cryocooler is reduced by configuring at least a portion of the acoustic impedance of a selected stage, higher than the first stage, so that it surrounds the cold head of the selected stage. The surrounding acoustic impedance of the selected stage is mounted in thermally conductive connection to the warm region of the selected stage for cooling the acoustic impedance and is fabricated of a high thermal diffusivity, low thermal radiation emissivity material, preferably aluminum.

  13. Numerical study on transverse asymmetry in the temperature profile of a regenerator in a pulse tube cooler

    DEFF Research Database (Denmark)

    Andersen, Stig Kildegård; Dietrich, M.; Carlsen, Henrik

    2007-01-01

    Transverse asymmetry in the temperature profile of the regenerator in a Stirling-type pulse tube cooler as observed in experiments was analysed in a numerical study. The asymmetry was reproduced using a one-dimensional model of the cooler where the regenerator was modelled using two identical...... parallel regenerator channels. The asymmetry was caused by a circulating flow that was superimposed on the oscillating flow. The primary mechanism driving the circulating flow was due to the wave form of the pressure difference between the ends of the regenerator and the dependence of the instantaneous...

  14. Numerical study on transverse asymmetry in the temperature profile of a regenerator in a pulse tube cooler

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Stig Kildegaard; Carlsen, Henrik [Department of Mechanical Engineering, Energy Engineering Section, Technical University of Denmark, Kgs. Lyngby (Denmark); Dietrich, Marc; Thummes, Guenter [Institute of Applied Physics, University of Giessen, D-35392 Giessen (Germany)

    2007-07-15

    Transverse asymmetry in the temperature profile of the regenerator in a Stirling-type pulse tube cooler as observed in experiments was analysed in a numerical study. The asymmetry was reproduced using a one-dimensional model of the cooler where the regenerator was modelled using two identical parallel regenerator channels. The asymmetry was caused by a circulating flow that was superimposed on the oscillating flow. The primary mechanism driving the circulating flow was due to the wave form of the pressure difference between the ends of the regenerator and the dependence of the instantaneous mass flow rate on the pressure difference and temperature. (author)

  15. Refrigeration Showcases

    Science.gov (United States)

    1997-01-01

    Through the Technology Affiliates Program at the Jet Propulsion Laboratory (JPL), valuable modifications were made to refrigerator displays built by Displaymor Manufacturing Company, Inc. By working with JPL, Displaymor could address stiffer requirements that ensure the freshness of foods. The application of the space technology meant that the small business would be able to continue to market its cases without incurring expenses that could threaten the viability of the business, and the future of several dozen jobs. Research and development improvements in air flow distribution and refrigeration coil technology contributed greatly to certifying Displaymor's showcases given the new federal regulations. These modifications resulted in a refrigerator case that will keep foods cooler, longer. Such changes maintained the openness of the display, critical to customer visibility and accessibility, impulse buying, and cross-merchandising.

  16. Evaporation of alternative refrigerants to R 22 in technical shell and tube heat exchangers; Verdampfung von Ersatzkaeltemitteln fuer R 22 in technischen Rohrbuendel-Waermeaustauschern

    Energy Technology Data Exchange (ETDEWEB)

    Bonekamp, S. [Henkel KGaA, Duesseldorf (Germany)

    2000-05-01

    The refrigerant mixtures R 404A, R 407C, R 410A and R 507 and the pure fluids R 134a, ammonia, propane and propene are mainly recommended for substituting R 22. This report shows the results of heat transfer calculations for these refrigerants over a wide application range for flooded and for direct expansion evaporation. To determine the best substitute for R 22 the heat transfer areas are compared and a ranking for both types of evaporators is presented. (orig.) [German] Als Ersatz fuer R 22 werden hauptsaechlich die Kaeltemittelgemische R 404A, R 407C, R 410A und R 507 sowie die reinen Stoffe R 134a, Ammoniak, Propan und Propen diskutiert. Diese Arbeit stellt Berechnungsergebnisse fuer die verschiedenen Ersatzkaeltemittel in einem grossen technischen Anwendungsbereich sowohl fuer ueberflutete als auch fuer Einspritz-Verdampfer vor. Der Vergleich der ermittelten Waermeaustauschflaechen liefert fuer beide Verdampfungsarten eine Reihenfolge fuer die Verwendbarkeit als Austauschstoff fuer R 22. (orig.)

  17. Refrigeration Servicing.

    Science.gov (United States)

    Hamilton, Donald L.; And Others

    This self-study course is designed to familiarize Marine enlisted personnel with the services required to be performed on refrigeration equipment. The course contains four study units. Each study unit begins with a general objective, which is a statement of what the student should learn from the unit. The study units are divided into numbered work…

  18. Development of high-capacity U-type pulse tube cryocoolers for a cold optics system in space applications

    Science.gov (United States)

    Dang, H. Z.; Li, S. S.; Wang, L. B.; Yang, K. X.; Shen, W. B.; Wu, Y. N.

    2010-04-01

    A robust U-type pulse tube cryocooler has been developed to replace the heavy and cumbersome passive radiator system for cooling the cold optics component of a sophisticated infrared sensors system used in a weather satellite. The U-type other than coaxial arrangement is chosen to obtain a robust and simple system, and also to avoid the potential loss introduced by the possible mismatch of the temperature profiles of pulse tube and regenerator as well. Besides the conventional integral "U"-shaped cold tip, a novel detachable two-half cold head is designed to enhance cooling performance. Some fine grooves are engraved in the cold head using electro discharge machining technology, which can not only increase the heat transfer area, but also serve as a straightener for the turbulence introduced by the flow reversal. The cooler is powered by a 7.5 cc dual opposed piston compressor and the overall weight is less than 11 kg. It can lift over 8.0W of heat at 150K with 87 W of electric input power and at 310 K of reject temperature. The design considers, experimental results, and performance analyses are presented.

  19. Design and array signal suggestion of array type pulsed eddy current probe for health monitoring of metal tubes

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Kil [Dept. of Electrical Engineering, Kunsan National University, Kunsan (Korea, Republic of)

    2015-10-15

    An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.

  20. The velocity of the arterial pulse wave: a viscous-fluid shock wave in an elastic tube

    Directory of Open Access Journals (Sweden)

    Painter Page R

    2008-07-01

    Full Text Available Abstract Background The arterial pulse is a viscous-fluid shock wave that is initiated by blood ejected from the heart. This wave travels away from the heart at a speed termed the pulse wave velocity (PWV. The PWV increases during the course of a number of diseases, and this increase is often attributed to arterial stiffness. As the pulse wave approaches a point in an artery, the pressure rises as does the pressure gradient. This pressure gradient increases the rate of blood flow ahead of the wave. The rate of blood flow ahead of the wave decreases with distance because the pressure gradient also decreases with distance ahead of the wave. Consequently, the amount of blood per unit length in a segment of an artery increases ahead of the wave, and this increase stretches the wall of the artery. As a result, the tension in the wall increases, and this results in an increase in the pressure of blood in the artery. Methods An expression for the PWV is derived from an equation describing the flow-pressure coupling (FPC for a pulse wave in an incompressible, viscous fluid in an elastic tube. The initial increase in force of the fluid in the tube is described by an increasing exponential function of time. The relationship between force gradient and fluid flow is approximated by an expression known to hold for a rigid tube. Results For large arteries, the PWV derived by this method agrees with the Korteweg-Moens equation for the PWV in a non-viscous fluid. For small arteries, the PWV is approximately proportional to the Korteweg-Moens velocity divided by the radius of the artery. The PWV in small arteries is also predicted to increase when the specific rate of increase in pressure as a function of time decreases. This rate decreases with increasing myocardial ischemia, suggesting an explanation for the observation that an increase in the PWV is a predictor of future myocardial infarction. The derivation of the equation for the PWV that has been used for

  1. Investigation of the effect of a bend in a transfer line that separates a pulse tube cold head and a pressure wave generator

    Science.gov (United States)

    Dev, A. A.; Atrey, M. D.; Vanapalli, S.

    2017-02-01

    A transfer line between a pulse tube cold head and a pressure wave generator is usually required to isolate the cold head from the vibrations of the compressor. Although it is a common practice to use a thin and narrow straight tube, a bent tube would allow design flexibility and easy mounting of the cold head, such as in a split Stirling type pulse tube cryocooler. In this paper, we report a preliminary investigation on the effect of the bending of the tube on the flow transfer characteristics. A numerical study using commercial computational fluid dynamics model is performed to gain insight into the flow characteristics in the bent tube. Oscillating flow experiments are performed with a straight and a bent tube at a filling pressure of 15 bar and an operating frequency of 40, 50 and 60 Hz. The data and the corresponding numerical simulations point to the hypothesis that the secondary flow in the bent tube causes a decrease in flow at a fixed pressure amplitude.

  2. A Computational Model for Two-stage 4K-Pulse Tube Cooler: Part I.Theoretical Model and Numerical Method

    Institute of Scientific and Technical Information of China (English)

    Y.L. Ju; A.T.A.M. de Waele

    2001-01-01

    A new mixed Eulerian-Lagrangian computational model for simulating and visualizing the internal processes and the variations of dynamic parameters of a two-stage pulse tube cooler (PTC) operating at 4 K-temperature region has been developed. We use the Lagrangian method, a set of moving grids, to follow the exact tracks of gas particles as they move with pressure oscillation in the pulse tube to avoid any numerical false diffusion. The Eulerian approach, a set of fixed computational grids, is used to simulate the variations of dynamic parameters in the regenerator. A variety of physical factors, such as real thermal properties of helium, multi-layered magnetic regenerative materials, pressure drop and heat transfer in the regenerator, and heat exchangers, are taken into account in this model. The present modeling is very effective for visualizing the internal physical processes in 4 K-pulse tube coolers.

  3. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  4. Thermal characterization of rods, tubes and spheres using pulsed infrared thermography

    Energy Technology Data Exchange (ETDEWEB)

    Apinaniz, E [Departamento de Fisica Aplicada I, Escuela Tecnica Superior de Ingenieria, Universidad del PaIs Vasco, Alameda Urquijo s/n, 48013 Bilbao (Spain); Mendioroz, A [Departamento de Fisica Aplicada I, Escuela Tecnica Superior de Ingenieria, Universidad del PaIs Vasco, Alameda Urquijo s/n, 48013 Bilbao (Spain); Madariaga, N [Departamento de Fisica Aplicada I, Escuela Tecnica Superior de Ingenieria, Universidad del PaIs Vasco, Alameda Urquijo s/n, 48013 Bilbao (Spain); Oleaga, A [Departamento de Fisica Aplicada I, Escuela Tecnica Superior de Ingenieria, Universidad del PaIs Vasco, Alameda Urquijo s/n, 48013 Bilbao (Spain); Celorrio, R [Departamento de Matematica Aplicada, Universidad de Zaragoza, Campus Rio Ebro, Edificio Torres Quevedo, 50018 Zaragoza (Spain); Salazar, A [Departamento de Fisica Aplicada I, Escuela Tecnica Superior de Ingenieria, Universidad del PaIs Vasco, Alameda Urquijo s/n, 48013 Bilbao (Spain)

    2008-01-07

    In this work we analyse the accuracy of an extension of the flash method to measure the thermal diffusivity of rods, tubes and spheres, which was recently proposed by the authors. We have performed measurements in a wide set of calibrated samples of different sizes and we have found that a lower limiting size of the radius can be established for the validity of the method. On the other hand, a procedure to retrieve the thermal conductivity of tubes, based on filling them with a contrast liquid (water), is proposed. Moreover, the thermal contact resistance between the two layers of coated cylinders is also obtained. Measurements on calibrated samples confirm the validity of the two latest methods.

  5. A useful method to monitor outputs from a pulsed light source and its application to rate effect studies in a photomultiplier tube

    CERN Document Server

    Takeuchi, Y; Kurashige, H; Matono, Y; Murakami, K; Nomura, T; Sakamoto, H; Sasao, N; Suehiro, M; Fukushima, Y; Ikegami, Y; Nakamura, T T; Taniguchi, T; Asai, M

    1999-01-01

    In order to study short-term gain stability in a photomultiplier tube at high counting rate, we constructed an LED pulsed light source and its output monitoring system. For the monitoring system, we employed a photon counting method using a photomultiplier as a monitor photon detector. It is found that the method offers a simple way to monitor outputs from a pulsed light source and that, together with an LED light source, it provides a useful method to investigate photomultiplier's rate effects.

  6. Refrigeration and Food Safety

    Science.gov (United States)

    ... Standard Forms FSIS United States Department of Agriculture Food Safety and Inspection Service About FSIS District Offices Careers ... Viewer (JSR 286) Actions ${title} Loading... Refrigeration and Food Safety History of Refrigeration Importance of Refrigeration Types of ...

  7. Anisotropic steady-flow hydrodynamic parameters of microporous media applied to pulse tube and Stirling cryocooler regenerators

    Science.gov (United States)

    Clearman, W. M.; Cha, J. S.; Ghiaasiaan, S. M.; Kirkconnell, C. S.

    2008-03-01

    The hydrodynamic parameters associated with steady longitudinal and lateral (radial) flow of helium in several widely-used pulse tube and Stirling cryocooler regenerator fillers were measured and correlated in this investigation. Pressure drops in test sections packed with regenerator fillers were experimentally measured. Computational fluid dynamics (CFD) models of the regenerator test sections and their vicinities were developed and simulations were performed in which the regenerator test sections were modeled as porous media. By iterative repetition of the simulations, the longitudinal and radial permeability and Forchheimer inertial coefficients were determined such that they would lead to agreement between experimental measurements and the simulations. The regenerator fillers included 325 and 400 mesh stainless steel screens, stainless steel metal foam, sintered 400 mesh stainless steel screens, and a stack of micromachined perforated plates. The hydrodynamic response of the regenerator fillers were also correlated as friction factors. The results confirm that the aforementioned regenerator fillers are anisotropic.

  8. A three-stage Stirling pulse tube cryocooler reached 4.26 K with He-4 working fluid

    Science.gov (United States)

    Zhi, X. Q.; Han, L.; Dietrich, M.; Gan, Z. H.; Qiu, L. M.; Thummes, G.

    2013-12-01

    Multi-stage Stirling pulse tube cryocoolers (SPTCs) working at liquid helium temperatures are attractive because of their promising potential in tactical and space applications. However, it is still a challenge for a SPTC to operate below 5 K with He-4 as working fluid instead of the rare He-3. In this study, the operating characteristics of an in-house made three-stage SPTC were experimentally investigated. The mutual influence of precooling temperature, operating frequency, input power, and charge pressure on the cooling performance of the third stage was studied. A no-load temperature of 4.26 K was achieved by the three-stage SPTC, which is the lowest temperature ever obtained by a multi-stage SPTC operating with He-4 as working fluid.

  9. 一种新结构U型脉冲管制冷机%A New Structural U-Shape Pulse Tube Cryocooler

    Institute of Scientific and Technical Information of China (English)

    尹传林; 陈厚磊; 蔡京辉

    2012-01-01

    在U型脉冲管制冷机结构基础上,研制了一台带有一个蓄冷器和两个相同脉管的新结构U型脉冲管制冷机,并进行了实验研究和分析。制冷机采用惯性管调相,在压缩机输入电功率80w,运行频率52Hz下,获得了120K@6W的制冷量。重点对两种惯性管调相方法进行研究和分析,得出了对新结构U型脉冲管制冷机调相有益的结论,并对惯性管调相过程中产生的直流现象进行了验证分析。%A new structural U-shape pulse tube cryocooler based on the U-shape pulse tube cryocooler, with one regenerator and the same two pulse tubes, has been designed and manufactured. The pulse cryocooler is able to gain 120 K@6 W cooling power with 80 W electric power at the operating frequency of 52 Hz. The method of the inertance tube phase-shifting is investigated and the useful conclusion is obtained for the pahse-shifting of new structural U-shape pulse tube cryocooler. The DC flow that occures in the inertance tube phase-shifting is also tested and analysed.

  10. Modelling refrigerant distribution in microchannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke; Kærn, Martin Ryhl; Elmegaard, Brian

    2009-01-01

    The effects of refrigerant maldistribution in parallel evaporator channels on the heat exchanger performance are investigated numerically. For this purpose a 1D steady state model of refrigerant R134a evaporating in a microchannel tube is built and validated against other evaporator models. A study...... of the refrigerant distribution is carried out for two channels in parallel and for two different cases. In the first case maldistribution of the inlet quality into the channels is considered, and in the second case a non-uniform airflow on the secondary side is considered. In both cases the total mixed superheat...

  11. Influence of regenerator void volume on performance of a precooled 4 K Stirling type pulse tube cryocooler

    Science.gov (United States)

    Li, Zhuopei; Jiang, Yanlong; Gan, Zhihua; Qiu, Limin; Chen, Jie

    2015-09-01

    Stirling type pulse tube cryocoolers (SPTC), typically operating at 30-60 Hz, have the advantage of compact structure, light weight, and long life compared with Gifford-McMahon type (1-2 Hz) PTC (GMPTC). The behavior of flow and heat transfer in the regenerator of a 4 K SPTC deviates from that at warmer temperatures and low frequencies. In this paper the behavior of 4 K regenerator at high frequencies is investigated based on a single-stage 4 K SPTC precooled by a two-stage GMPTC. The 4 K SPTC and the GMPTC is thermally coupled with two thermal bridges. The 4 K SPTC uses a 10 K cold inertance tube as phase shifter to improve phase relationship between mass flow and pressure. The regenerator void volume is an important factor that significantly influences the heat transfer between regenerator matrix and working fluid helium, pressure drop along the regenerator, and phase shift between mass flow and pressure. In this paper, influence of regenerator void volume on the performance of the 4 K SPTC with different operating parameters including operating frequencies and average pressure is studied theoretically and experimentally. The first and second precooling powers provided by the GMPTC are obtained which are important parameters to evaluate the efficiency of the whole 4 K system with precooling. The results of the regenerator void volume are given and discussed in normalized form for general use.

  12. Managing Refrigerant Emissions

    Science.gov (United States)

    Access information on EPA's efforts to address ozone layer depletion by reducing emissions of refrigerants from stationary refrigeration and air conditioning systems and motor vehicle air conditioning systems.

  13. Experimental Investigation on Heating Kerosene Using Thrust Tube Waste Heat of Pulse Detonation Engine

    Science.gov (United States)

    Huang, Xiqiao; Yan, Yu; Mu, Yang; Zheng, Longxi; Chen, Le

    2013-12-01

    Performance of liquid hydrocarbon fueled pulse detonation engines are hindered by the time required to evaporate liquid fuel droplets within the mixture. Efforts such as heating the liquid fuel before introduced into the engine were made to overcome this problem. The engine wall suffered high temperature of gaseous detonative products, which is harmful to the engine. Therefore the waste heat of PDE engine wall was used here to heat the liquid kerosene of the engine by using two concentric heat-exchangers with helical slot inside mounted at the tail of the pulse detonation engine. The pulse detonation engine (PDE) used here are 110 mm in inner diameter and 1700 mm in length and liquid kerosene and gaseous air were used as fuel and oxidizer respectively. Heating liquid kerosene was found effective in enhancing the engine performance, which was helpful for deflagration to detonation transition process. It was found that the waste heat could elevate the kerosene temperature effectively and the wall temperature could also be decreased obviously.

  14. Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler

    NARCIS (Netherlands)

    Pang, Xiaomin; Dai, Wei; Wang, Xiaotao; Vanapalli, S.; Luo, Ercang

    2016-01-01

    Improving the performance of the pulse tube cooler is one of the important objectives of the current studies. Besides the phase shifters and regenerators, heat exchangers also play an important role in determining the system efficiency and cooling capacity. A series of experiments on a 10 W @ 77 K c

  15. 15-25K Static-Helium Regenerator/Double Pulse Tube Cooler for Receiving Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA needs a cryogenic refrigerator for the 15-25K range for receiving arrays of ground-based antennas that will serve the telecommunications needs of future space...

  16. Literature survey of heat transfer enhancement techniques in refrigeration applications

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

    1994-05-01

    A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

  17. Characteristics of Spherical Shock Wave and Circular Pulse Jet Generated by Discharge of Propagating Shock Wave at Open End of Tube

    Institute of Scientific and Technical Information of China (English)

    Tsukasa Irie; Tsuyoshi Yasunobu; Hideo Kashimura; Toshiaki Setoguchi; Kazuyasu Matsuo

    2003-01-01

    When the shock wave propagating in the straight circular tube reaches at the open end, the impulsive wave is generated by the emission of a shock wave from an open end, and unsteady pulse jet is formed near the open end behind the impulsive wave under the specific condition. The pulse jet transits to spherical shock wave with the increase in the strength of shock wave. The strength is dependent on the Mach number of shock wave, which attenuates by propagation distance from the open end. In this study, the mechanism of generating the unsteady pulse jet, the characteristics of the pressure distribution in the flow field and the emission of shock wave from straight circular tube which has the infinite flange at open end are analyzed numerically by the TVD method. Strength of spherical shock wave, relation of shock wave Mach number, distance decay of spherical shock wave and directional characteristics are clarified.

  18. Boiling Heat Transfer to Halogenated Hydrocarbon Refrigerants

    Science.gov (United States)

    Yoshida, Suguru; Fujita, Yasunobu

    The current state of knowledge on heat transfer to boiling refrigerants (halogenated hydrocarbons) in a pool and flowing inside a horizontal tube is reviewed with an emphasis on information relevant to the design of refrigerant evaporators, and some recommendations are made for future research. The review covers two-phase flow pattern, heat transfer characteristics, correlation of heat transfer coefficient, influence of oil, heat transfer augmentation, boiling from tube-bundle, influence of return bend, burnout heat flux, film boiling, dryout and post-dryout heat transfer.

  19. Calculation base of flooded type evaporators with finned tubes

    Energy Technology Data Exchange (ETDEWEB)

    Brod, W.; Slipcevic, B.

    1989-03-01

    For the construction of flooded type evaporators with halogen refrigerants, the refrigeration industry is using finned tubes. Equations for thermodynamical calculations of the apparaturs are given, and explained with the aid of a calculation example.

  20. Performance of a small, low-lift regenerator-based thermoacoustic refrigerator

    Science.gov (United States)

    Poese, Matthew E.; Garrett, Steven L.

    2002-11-01

    A regenerator-based thermoacoustic refrigerator [Swift, Gardner, and Backhaus, ''Acoustic recovery of lost power in pulse tube refrigerators,'' J. Acoust. Soc. Am. 105(2), 711 (1999)] has been constructed. It is capable of moving about 5 W across a 40degC temperature span. The machine operates with air at atmospheric pressure and is driven by an off-the-shelf electro-dynamic loudspeaker capable of producing peak-to-mean pressure ratios up to 12%. The thermal core of this research device contains an exhaust-side shell and tube heat exchanger (with water as the secondary heat transfer fluid), a regenerator made of 88 annular stainless-steel screens, and a constantan wire electrical heater that applies a measurable heat load to the cold side of the regenerator. An annular latex diaphragm is placed over the cold side of the regenerator to stop time-averaged mass flow through the regenerator and insulate the cold side [Gedeon, ''DC Gas Flows in Stirling and Pulse Tube Cryocoolers,'' in Cryocoolers 9, edited by R. G. Ross (Plenum, New York, 1997)]. Detailed measurements of heat load, temperature span, and exhaust heat flux will be presented and compared to DeltaE. [Work supported by ONR.

  1. Design of a scanning gate microscope in a cryogen-free dilution refrigerator

    CERN Document Server

    Pelliccione, Matthew; Bartel, John; Keller, Andrew; Goldhaber-Gordon, David

    2012-01-01

    We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in recent years. However, this new style of cryostat presents challenges for performing scanning probe measurements, mainly as a result of the vibrations introduced by the cryocooler. We demonstrate scanning with root-mean-square vibrations of 0.8 nm at 3 K and 2.1 nm at 15 mK in a 1 kHz bandwidth with our design.

  2. The Refrigeration System; Appliance Repair--Advanced: 9027.01.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This course outline provides students with an understanding of the observation of basic refrigeration system components, the techniques used in working with copper tubing, and practice demonstrations to show what they have learned. Course content includes specific block objectives, orientation, refrigeration components (evaporator, compressor,…

  3. Refrigeration and Cryogenics Specialist. J3ABR54530

    Science.gov (United States)

    Air Force Training Command, Sheppard AFB, TX.

    This document package contains an Air Force course used to train refrigeration and cryogenics specialists. The course is organized in six blocks designed for group instruction. The blocks cover the following topics: electrical principles; fundamentals of tubing and piping; metering devices, motor controls, domestic and commercial refrigeration;…

  4. Stirling Refrigerator

    Science.gov (United States)

    Kagawa, Noboru

    A Stirling cooler (refrigerator) was proposed in 1862 and the first Stirling cooler was put on market in 1955. Since then, many Stirling coolers have been developed and marketed as cryocoolers. Recently, Stirling cycle machines for heating and cooling at near-ambient temperatures between 173 and 400K, are recognized as promising candidates for alternative system which are more compatible with people and the Earth. The ideal cycles of Stirling cycle machine offer the highest thermal efficiencies and the working fluids do not cause serious environmental problems of ozone depletion and global warming. In this review, the basic thermodynamics of Stirling cycle are briefly described to quantify the attractive cycle performance. The fundamentals to realize actual Stirling coolers and heat pumps are introduced in detail. The current status of the Stirling cycle machine technologies is reviewed. Some machines have almost achieved the target performance. Also, duplex-Stirling-cycle and Vuilleumier-cycle machines and their performance are introduced.

  5. Pulse

    Science.gov (United States)

    ... resting for at least 10 minutes. Take the exercise heart rate while you are exercising. ... pulse rate can help determine if the person's heart is pumping. Pulse ... rate gives information about your fitness level and health.

  6. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-11-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  7. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-07-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  8. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1999-01-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  9. Theoretical and Experimental Investigation of a 4 K Single-Stage Stirling Type Pulse Tube Cryocooler with Precooling

    Science.gov (United States)

    Li, Z. P.; Chen, J.; Gan, Z. H.; Qiu, L. M.

    2010-04-01

    The efficiency of 4 K Stirling type pulse tube cryocoolers (SPTC) is rather low compared with that of 80 K SPTCs. Real gas effects and low specific heat capacity ratio of regenerator matrix to helium near 4 K are the main reasons that lead to the low efficiency of 4 K SPTC. A single-stage Stirling type PTC precooled by a two-stage G-M type PTC is developed to study the performance of 4 K Stirling type PTC with a focus on the performance of the regenerator working at 4 K-10 K. In order to reduce loss associated with real gas effects, relatively low average pressure was used. Gd2O2S (GOS) was used as regenerator matrix to replace HoCu2 around 4 K to decrease the regenerator loss caused by ineffective heat transfer between regenerator matrix and helium. A systematic comparison between the two types of regenerator matrix was made theoretically and experimentally including effect of frequency, average pressure and precooling temperature. Performance of the linear compressor is also presented in this paper.

  10. A modified two-stage pulse tube cryocooler utilizing double-inlet and multi-mesh regenerator

    Science.gov (United States)

    Arablu, M.; Jafarian, A.

    2013-12-01

    In this paper a thermally coupled Stirling-type two-stage pulse tube cryocoolers (TSPTC) is studied using a one-dimensional (1-D) CFD code. After validating the results of the simulations, effects of synchronous utilization of multi-mesh regenerator and double-inlet on the performance of the TSPTC are investigated. Results of simulations show that non-oscillating friction factors do not possess sufficient accuracy for calculation of oscillating friction losses in non-porous media. Whereas, using oscillating friction factor of non-porous media leads to sufficient accurate results. According to the results, using multi-mesh regenerator and double-inlet increases the COP and decreases the minimum attainable temperature of the system. It is observed that a minimum temperature of 18.2 K is attainable using optimum multi-mesh regenerator and double-inlet; whereas, for a simple TSPTC with a uniform mesh regenerator, a minimum temperature of 26.4 K is concluded.

  11. Ultra-low vibration pulse-tube cryocooler stabilized cryogenic sapphire oscillator with 10^-16 fractional frequency stability

    CERN Document Server

    Hartnett, John G

    2010-01-01

    A low maintenance long-term operational cryogenic sapphire oscillator has been implemented at 11.2 GHz using an ultra-low-vibration cryostat and pulse-tube cryocooler. It is currently the world's most stable microwave oscillator employing a cryocooler. Its performance is explained in terms of temperature and frequency stability. The phase noise and the Allan deviation of frequency fluctuations have been evaluated by comparing it to an ultra-stable liquid-helium cooled cryogenic sapphire oscillator in the same laboratory. Assuming both contribute equally, the Allan deviation evaluated for the cryocooled oscillator is sigma_y = 1 x 10^-15 tau^-1/2 for integration times 1 < tau < 10 s with a minimum sigma_y = 3.9 x 10^-16 at tau = 20 s. The long term frequency drift is less than 5 x 10^-14/day. From the measured power spectral density of phase fluctuations the single side band phase noise can be represented by L_phi(f) = 10^-14.0/f^4+10^-11.6/f^3+10^-10.0/f^2+10^-10.2/f+ 10^-11.0 for Fourier frequencies 10...

  12. Simulation technology for refrigeration and air conditioning appliances

    Institute of Scientific and Technical Information of China (English)

    DING Guoliang

    2006-01-01

    Simulation technology has been widely used for performance prediction and optimal design of refrigeration and air conditioning appliances. A brief history of simulation technology for refrigeration and air conditioning appliances is reviewed. The models for evaporator, condenser, compressor, capillary tube and thermal insulation layer are summarized, and a fast calculation method for thermodynamic properties of refrigerant is introduced in this paper. The model-based intelligent simulation technology and the simulation technology based on graph theory are also illustrated. Finally, an updated trend of simulation technology development for refrigeration and air conditioning appliances is discussed.

  13. Refrigerating machine oil

    Energy Technology Data Exchange (ETDEWEB)

    Nozawa, K.

    1981-03-17

    Refrigerating machine oil to be filled in a sealed motorcompressor unit constituting a refrigerating cycle system including an electric refrigerator, an electric cold-storage box, a small-scaled electric refrigerating show-case, a small-scaled electric cold-storage show-case and the like, is arranged to have a specifically enhanced property, in which smaller initial driving power consumption of the sealed motor-compressor and easier supply of the predetermined amount of the refrigerating machine oil to the refrigerating system are both guaranteed even in a rather low environmental temperature condition.

  14. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1994-05-27

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  15. Docmentation of newly developed methods to assess material compatibility in refrigeration and air-conditioning applications. Final report, 1 October 1993--31 August 1994

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, M.

    1994-08-01

    This document summarizes the experimental methods used during the materials compatibility and lubricants research program (MCLR). The MCLR program was jointly sponsored by the U.S. Department of Energy and the air-conditioning and refrigeration industry. The individual projects were managed by the Air-Conditioning and Refrigeration Technology Institute. The projects presented in this report are: Chemical and Thermal Stability of Refrigerant/Lubricant Mixtures with Metals, Miscibility of Lubricants with Refrigerants, Compatibility of Refrigerants and Lubricants with Motor Materials, Compatibility of Refrigerants and Lubricants with Elastomers, Compatibility of Refrigerants and Lubricants with Engineering Plastics and Sealed Tube Comparisons of the Compatibility of Desiccants with Refrigerants and Lubricants.

  16. Reactions of 1-naphthyl radicals with ethylene. Single pulse shock tube experiments, quantum chemical, transition state theory, and multiwell calculations.

    Science.gov (United States)

    Lifshitz, Assa; Tamburu, Carmen; Dubnikova, Faina

    2008-02-07

    The reactions of 1-naphthyl radicals with ethylene were studied behind reflected shock waves in a single pulse shock tube, covering the temperature range 950-1200 K at overall densities behind the reflected shocks of approximately 2.5 x 10(-5) mol/cm3. 1-Iodonaphthalene served as the source for 1-naphthyl radicals as its C-I bond dissociation energy is relatively small. It is only approximately 65 kcal/mol as compared to the C-H bond strength in naphthalene which is approximately 112 kcal/mol and can thus produce naphthyl radicals at rather low reflected shock temperatures. The [ethylene]/[1-iodo-naphthalene] ratio in all of the experiments was approximately 100 in order to channel the free radicals into reactions with ethylene rather than iodonaphthalene. Four products resulting from the reactions of 1-naphthyl radicals with ethylene were found in the post shock samples. They were vinyl naphthalene, acenaphthene, acenaphthylene, and naphthalene. Some low molecular weight aliphatic products at rather low concentrations, resulting from the attack of various free radicals on ethylene were also found in the shocked samples. In view of the relatively low temperatures employed in the present experiments, the unimolecular decomposition rate of ethylene is negligible. Three potential energy surfaces describing the production of vinyl naphthalene, acenaphthene, and acenaphthylene were calculated using quantum chemical methods and rate constants for the elementary steps on the surfaces were calculated using transition state theory. Naphthalene is not part of the reactions on the surfaces. Acenaphthylene is obtained only from acenaphthene. A kinetics scheme containing 27 elementary steps most of which were obtained from the potential energy surfaces was constructed and computer modeling was performed. An excellent agreement between the experimental yields of the four major products and the calculated yields was obtained.

  17. Development of Magnetic Refrigerator

    Science.gov (United States)

    Ogiwara, Hiroyasu; Nakagome, Hideki; Kuriyama, Tohru

    A series of R & D of magnetic refrigerators has been done in order to realize an advanced type cryocooler for superconducting magnets of maglev trains and MRI medical system. As a result of efforts on both the magnetic refrigerator and superconducting magnets, a parasitic type magnetic refrigeration system was proposed.

  18. Coefficient of Performance Enhancement of Refrigeration Cycles

    Directory of Open Access Journals (Sweden)

    Eng. Naser R. M. AL-Ajmi

    2015-03-01

    Full Text Available Refrigerator is one of the home appliance utilizing mechanical vapor compression cycle in its process. Performance of the systems become the main issue and many researches are still ongoing to evaluate and improve the efficiency of any used system. Therefore, this paper presents an experimental investigation of the performance of the refrigeration cycles. A small rrefrigerator is used as the test rig. The Coefficient of Performance (COP is studied by using different condenser designs and under varying evaporator loads. Three condenser designs are used in present work. These condensers are regular condenser of domestic refrigerator, condenser with copper plain tubes (Cond.1 and condenser with copper tubes welded with stainless steel flat plate (Cond.2. pressures and temperatures measurements of each point in the refrigeration cycle are collected in order to evaluate the refrigerator performance. The results showed that the average COP of Cond.1 and Cond.2 are increased up to 20 % and 14% respectively more than regular condenser design under no load. The evaporator load effects on the machine performance, where the COP of the machine increases with the increase of the evaporator load.

  19. Operation of a Wideband Terahertz Superconducting Bolometer Responding to Quantum Cascade Laser Pulses

    Science.gov (United States)

    Cibella, S.; Beck, M.; Carelli, P.; Castellano, M. G.; Chiarello, F.; Faist, J.; Leoni, R.; Ortolani, M.; Sabbatini, L.; Scalari, G.; Torrioli, G.; Turcinkova, D.

    2012-06-01

    We make use of a niobium film to produce a micrometric vacuum-bridge superconducting bolometer responding to THz frequency. The bolometer works anywhere in the temperature range 2-7 K, which can be easily reached in helium bath cryostats or closed-cycle cryocoolers. In this work the bolometer is mounted on a pulse tube refrigerator and operated to measure the equivalent noise power (NEP) and the response to fast (μs) terahertz pulses. The NEP above 100 Hz equals that measured in a liquid helium cryostat showing that potential drawbacks related to the use of a pulse tube refrigerator (like mechanical and thermal oscillations, electromagnetic interference, noise) are irrelevant. At low frequency, instead, the pulse tube expansion-compression cycles originate lines at 1 Hz and harmonics in the noise spectrum. The bolometer was illuminated with THz single pulses coming either from a Quantum Cascade Laser operating at liquid nitrogen temperature or from a frequency-multiplied electronic oscillator. The response of the bolometer to the single pulses show that the device can track signals with a rise time as fast as about 450 ns.

  20. Influence of the nozzle angle on refrigeration performance of a gas wave refrigerator

    Science.gov (United States)

    Liu, P.; Zhu, Y.; Wang, H.; Zhu, C.; Zou, J.; Wu, J.; Hu, D.

    2016-09-01

    A gas wave refrigerator (GWR) is a novel refrigerating device that refrigerates a medium by shock waves and expansion waves generated by gas pressure energy. In a typical GWR, the injection energy losses between the nozzle and the expansion tube are essential factors which influence the refrigeration efficiency. In this study, numerical simulations are used to analyze the underlying mechanism of the injection energy losses. The results of simulations show that the vortex loss, mixing energy loss, and oblique shock wave reflection loss are the main factors contributing to the injection energy losses in the expansion tube. Furthermore, the jet angle of the gas is found to dominate the injection energy losses. Therefore, the optimum jet angle is theoretically calculated based on the velocity triangle method. The value of the optimum jet angle is found to be 4°, 8°, and 12° when the refrigeration efficiency is the first-order, second-order, and third-order maximum value over all working ranges of jet frequency, respectively. Finally, a series of experiments are conducted with the jet angle ranging from -4° to 12° at a constant expansion ratio. The results indicate the optimal jet angle obtained by the experiments is in good agreement with the calculated value. The isentropic refrigeration efficiency increased by about 4 % after the jet angle was optimized.

  1. 高效同轴脉冲管制冷机性能的实验研究%EXPERIMENTAL STUDY OF A HIGH EFFICIENT COAXIAL PULSE TUBE CRYOCOOLER

    Institute of Scientific and Technical Information of China (English)

    黄宇; 胡剑英; 戴巍; 罗二仓

    2011-01-01

    同轴式脉冲管制冷机具有结构紧凑、与器件耦合简单的优点,在实际应用中得到了越来越广泛的采用.本文对一台经理论优化设计的高频同轴脉冲管制冷机进行了实验研究,采用自制的直线压缩机驱动,惯性管/气库作为调相机构,在输入电功150 W、冷端温度为77 K时得到了9.86 W的制冷量,相对卡诺效率达到18.4%,这是目前同轴脉冲管制冷机报道的最好结果.%A coaxial pulse tube cryocooler has the advantage of compact structure and easy coupling with the loads, which make it widely used in application. In this paper, experimental study has been carried out for a coaxial pulse tube cryocooler which is driven by a self-designed linear compressor and uses an inertance tube with a reservoir as the phase shifter. With 150 W input electric power, the pulse tube cryocooler can obtained a cooling power of 9.86 W at 77 K. The corresponding relative Carnot efficiency is 18.4% which is the best result that have been reported.

  2. Concepts for a low-vibration and cryogen-free tabletop dilution refrigerator

    Science.gov (United States)

    Uhlig, Kurt

    2017-10-01

    The purpose of this article is to describe several concepts of how to cool a modern tabletop dilution refrigerator (DR) with a cryogen-free pulse tube cryocooler (PTC). Tabletop DRs have come more and more into the focus of scientists, recently, because they offer easy access to the mixing chamber mounting plate from all directions and because of their very short cooldown times. However, these milli-Kelvin coolers are precooled with LHe which makes their handling inconvenient and often expensive. In the paper it is explained how a cryocooler can be directly coupled to a DR unit making the use of LHe superfluous. Furthermore, concepts are discussed where a tabletop DR is cooled by a remote PTC; PTC and DR are mounted in separate vacuum containers which are connected by a stainless steel bellows tube. This kind of apparatus would offer an extremely low level of vibration at the mixing chamber mounting plate.

  3. Magnetic refrigeration materials

    Institute of Scientific and Technical Information of China (English)

    戴闻; 沈保根; 高政祥

    2001-01-01

    Magnetic refrigeration has drawn much attention because of its greater efficiency and higher reliability than the traditional gas-cycle refrigeration technology. Recently, a kind of new materials with a giant magnetocaloric effect in the subroom temperature range, Gd5 (Six Ge1- x)4, was discovered, which boosts the search for high-performance magnetic refrigerants. However, the intermetallic compounds Gd5 (SixGe1 - x )4 belong to the first order transition materials; their performance in practical magnetic refrigeration cycles remains controversial. In this paper the developing tendency of the refrigerants are discussed on the basis of our work.

  4. STUDY ON Valve TYPE ORIFICE PULSE TUBE REFRIGERATOR REACHED 34K%有阀型小孔脉管制冷机的深入研究

    Institute of Scientific and Technical Information of China (English)

    邱利民; 陈国邦

    1999-01-01

    为了克服第三代脉管制冷机存在的制冷温度不稳定的缺陷,本文从提高脉管制冷效率,进一步降低制冷温度的角度,对有阀型小孔脉管制冷机进行了研究.通过理论计算和实验改进,有阀型单级脉管制冷机取得了34K的无负荷制冷温度,在80 K获得30 W以上的制冷功率,其制冷效率达到国外同类商品型有阀脉管制冷机的水平.

  5. About Solar Refrigeration

    Directory of Open Access Journals (Sweden)

    Laura Coroiu

    2008-05-01

    Full Text Available This paper has the purpose to unfold the results of all researches which proved before that the solar energy constitutes itself as an ideal resource for heating application that necessitate lower temperature,e.g. the heating of a certain space or the preparation ofthe domestic hot water. The refrigeration systems, which are based on the nontoxic refrigerants for the environment, offer a sustained advantage when compared to the other types of the refrigerants. But, whichever might be the case, the use of the energy associated to the operation of the refrigeration system and with the impact that it has upon the environment, as well as the association with its production and distribution, have often a bigger importance than the selection of the refrigerant. In order to minimize the impact which the operation of the refrigeration systems exerts upon the environment, it is recommended that there should be checked all thepossibilities of using a pure source of energy.

  6. Numerical simulation of the effects of a suction line heat exchanger on vapor compression refrigeration cycle performance

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Hwan; Park, Sang Goo; Sarker, Debasish [Pusan National University, Busan (Korea, Republic of); Chang, Keun Sun [Sunmoon University, Asan (Korea, Republic of)

    2012-04-15

    Most modern refrigerators incorporate heat transfer between the refrigerant in a capillary tube and the refrigerant in a suction line. This heat transfer is achieved by a non-adiabatic capillary tube called a capillary tube-suction line heat exchanger and is supposed to improve the performance of the small vapor compression refrigeration cycle by removing some enthalpy of the refrigerant at the evaporator entrance. To investigate the effects of this heat transfer on the refrigeration cycle, a computer program was developed based on conservation equations of mass, momentum, and energy. The non-adiabatic capillary tube model is based on a homogeneous two-phase flow model. The simulation results show that both the location and length of the heat exchange section influence the coefficient of performance (COP) as well as the cooling capacity. It is noteworthy that the influence was not monotonic; that is, the performance may be deteriorated under certain conditions.

  7. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-02-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  8. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1998-08-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  9. Temperature and pressure control in the discharge of refrigeration systems cooled by shell and tube condensers; Control de presion y temperatura de descarga en sistemas de refrigeracion enfriados por condensadores de casco y tubo

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Martinez, R. [Asociacion de Ingenieros Egresados de la Universidad Autonoma Metropolitana, Mexico D. F. (Mexico)

    1995-12-31

    In the selection of a refrigeration equipment, the evaporator and condenser load conditions must be perfectly known, that is, the amount of heat energy that we have to reject from our space to cool in base to the temperature and mass to refrigerate. This situation carries on to the selection of the adequate compressor. But nevertheless the temperature conditions of the environment play an important roll in the behavior of the entire refrigeration system, altering in many cases the working conditions of each one of the components and therefore the functioning of the refrigeration system. This paper presents a method for controlling the behavior of each one of the components of the refrigeration system that perform in accordance with their design characteristics. [Espanol] En la seleccion de un equipo de refrigeracion, se deben conocer perfectamente las condiciones de carga del evaporador y del condensador, es decir la cantidad de calor que debemos de eliminar de nuestro medio a refrigerar, en base a la temperatura y masa a refrigerar. Esta situacion conlleva a la eleccion del compresor adecuado. Mas sin embargo, las condiciones de temperatura ambiente, juegan un papel importante en el comportamiento de todo el sistema de refrigeracion, alterando en muchos casos las condiciones de trabajo de cada uno de los componentes y por ende el funcionamiento del sistema de refrigeracion. El presente trabajo presenta un metodo para controlar el comportamiento de cada uno de los componentes dentro del sistema de refrigeracion para que trabajen de acuerdo a su diseno.

  10. Influence of Oil on Refrigerant Evaporator Performance

    Science.gov (United States)

    Kim, Jong-Soo; Nagata, Karsuya; Katsuta, Masafumi; Tomosugi, Hiroyuki; Kikuchi, Kouichiro; Horichi, Toshiaki

    In vapor compression refrigeration system using oil-lubricated compressors, some amount of oil is always circulated through the system. Oil circulation can have a significant influence on the evaporator performance of automotive air conditioner which is especially required to cool quickly the car interior after a period standing in the sun. An experimental investigation was carried out an electrically heated horizontal tube to measure local heat transfer coefficients for various flow rates and heat fluxes during forced convection boiling of pure refrigerant R12 and refrigerant-oil mixtures (0-11% oil concentration by weight) and the results were compared with oil free performance. Local heat transfer coefficients increased at the region of low vapor quality by the addition of oil. On the other hand, because the oil-rich liquid film was formed on the heat transfer surface, heat transfer coefficients gradually decreased as the vapor quality became higher. Average heat transfer coefficient reached a maximum at about 4% oil concentration and this trend agreed well with the results of Green and Furse. Previous correlations, using the properties of the refrigerant-oil mixture, could not predict satisfactorily the local heat transfer coefficients data. New correlation modified by oil concentration factor was developed for predicting the corresponding heat transfer coefficient for refrigerant-oil mixture convection boiling. The maximum percent deviation between predicted and measured heat transfer coefficient was within ±30%.

  11. Copper Oxide Nanoparticles for Advanced Refrigerant Thermophysical Properties: Mathematical Modeling

    Directory of Open Access Journals (Sweden)

    S. A. Fadhilah

    2014-01-01

    Full Text Available In modern days, refrigeration systems are important for industrial and domestic applications. The systems consume more electricity as compared to other appliances. The refrigeration systems have been investigated thoroughly in many ways to reduce the energy consumption. Hence, nanorefrigerant which is one kind of nanofluids has been introduced as a superior properties refrigerant that increased the heat transfer rate in the refrigeration system. Many types of materials could be used as the nanoparticles to be suspended into the conventional refrigerants. In this study, the effect of the suspended copper oxide (CuO nanoparticles into the 1,1,1,2-tetrafluoroethane, R-134a is investigated by using mathematical modeling. The investigation includes the thermal conductivity, dynamic viscosity, and heat transfer rate of the nanorefrigerant in a tube of evaporator. The results show enhanced thermophysical properties of nanorefrigerant compared to the conventional refrigerant. These advanced thermophysical properties increased the heat transfer rate in the tube. The nanorefrigerant could be a potential working fluid to be used in the refrigeration system to increase the heat transfer characteristics and save the energy usage.

  12. Investigation of synchronous effects of multi-mesh regenerator and double-inlet on performance of a Stirling pulse tube cryocooler

    Science.gov (United States)

    Arablu, M.; Jafarian, A.

    2013-02-01

    In this paper synchronous effects of multi-mesh regenerator and double-inlet on performance of a Stirling pulse tube cryocooler (SPTC) have been considered. In this respect, a finite volume code was developed to simulate the SPTC. Set of governing equations were written in a general form such that all porous and non-porous sections of the system could be modeled. Results showed that synchronous application of double inlet and multi-mesh regenerator optimizes the phase shift between velocity and pressure at the warm end of the pulse tube, increases the regenerator's outlet pressure amplitude, decreases inertial and viscous losses in the hot end of the regenerator and consequently increases the COP of the system. Furthermore, it was observed that a minimum temperature of 60.3 K and COP of 0.03996 @ 80 K is attainable using optimum multi-mesh regenerator and double inlet; whereas, for a simple SPTC with a uniform mesh regenerator, a minimum temperature of 71.3 K and maximum COP of 0.0227 @ 80 K are concluded.

  13. INVESTIGATION OF PULSE TUBE CRYOCOOLERS WITH GAS MIXTURE%混合工质在脉管制冷中应用初探

    Institute of Scientific and Technical Information of China (English)

    何雅玲; 高成名; 陈钟颀; 陶文铨

    2001-01-01

    In order to investigate the feasibility of using the gas mixture in the pulse tube cryocooler,the mixture of hydrogen and helium was chosen as the working fluid in cryocooler and an orifice pulse tube cryocooler was analyzed by the numerical simulation.It is found that the performance of the cryocooler has relation with the thermodynamic properties of the working fluid.The optimal percentage of the mixtures can be found.With this percentage the performance of the cryocooler has been improved.It is useful for increasing the cooling power and COP.%为了探讨混合工质在脉管制冷机中应用的可行性,选取氦气和氢气混合物作为工质,对一台小孔型脉管制冷机进行了数值模拟分析。结果发现,脉管制冷机的性能与其工质的热物性有很大关系。通过调整混合工质的配比,改变工质的物性,使其在混合工质最佳配比下工作,对于改进制冷机的性能,提高制冷量和制冷系数等都是有益处的。

  14. Experimental study of the influence of cold heat exchanger geometry on the performance of a co-axial pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Dai, Wei; Wang, Xiaotao; Vanapalli, S.; Luo, Ercang

    2016-09-01

    Improving the performance of the pulse tube cooler is one of the important objectives of the current studies. Besides the phase shifters and regenerators, heat exchangers also play an important role in determining the system efficiency and cooling capacity. A series of experiments on a 10 W @ 77 K class co-axial type pulse tube cooler with different cold heat exchanger geometries are presented in this paper. The cold heat exchangers are made from a copper block with radial slots, cut through using electrical discharge machining. Different slot widths varying from 0.12 mm to 0.4 mm and different slot numbers varying from around 20-60 are investigated, while the length of cold heat exchangers are kept the same. The cold heat exchanger geometry is classified into three groups, namely, constant heat transfer area, constant porosity and constant slot width. The study reveals that a large channel width of 0.4 mm (about ten times the thermal penetration depth of helium gas at 77 K, 100 Hz and 3.5 MPa) shows poor performance, the other results show complicated interaction effects between slot width and slot number. These systematic comparison experiments provide a useful reference for selecting a cold heat exchanger geometry in a practical cooler.

  15. Exploring the polymerization of bioactive nano-cones on the inner surface of an organic tube by an atmospheric pressure pulsed micro-plasma jet

    Science.gov (United States)

    Xu, H. M.; Yu, J. S.; Chen, G. L.; Qiu, X. P.; Hu, W.; Chen, W. X.; Bai, H. Y.

    2015-12-01

    In this paper, the successful deposition of acrylic acid polymer (PAA) nano-cones on the inner surface of a polyvinyl chloride (PVC) tube using an atmospheric pressure pulsed plasma jet (APPJ) with acrylic acid (AA) monomer is presented. Optical emission spectroscopy (OES) measurements indicated that various reactive radicals, such as rad OH and rad O, existed in the plasma jet. Moreover, the pulsed current proportionally increased with the increase in the applied voltage. The strengthened stretching vibration of the carbonyl group (Cdbnd O) at 1700 cm-1, shown in the ATR-FTIR spectra, clearly indicated that the PAA was deposited on the PVC surface. The maximum height of the PAA nano-cones deposited by this method ranged from 150 to 200 nm. FTIR and XPS results confirmed the enhanced exposure of the carboxyl groups on the modified PVC surface, which was considered highly beneficial for successfully immobilizing a high density of biomolecules. The XPS data showed that the carbon ratios of the Csbnd OH/R and COOH/R groups increased from 7.03% and 2.6% to 18.69% and 6.81%, respectively (more than doubled) when an Ar/O2 plasma with AA monomer was applied to treat the inner surface of the PVC tube. Moreover, the enhanced attachment density of MC3T3-E1 bone cells was observed on the PVC inner surface coated with PAA nano-cones.

  16. Heat Transfer Performance for Evaporator of Absorption Refrigerating Machine

    Science.gov (United States)

    Kunugi, Yoshifumi; Usui, Sanpei; Ouchi, Tomihisa; Fukuda, Tamio

    An experiment was conducted to check the heat transfer performance of evaporators with grooved tubes for absorption refrigerating machines. Heat transfer rate of evaporators were 35kW and 70kW. The range of the flow rate of the sprayed refrigerant per unit length Γ was 1 to 50kg/hm, and the outside diameters of the tubes, D0 were 16 and 19.6 mm. About 80 to 100 % increase of heat transfer rate over a plane surfaced tube is obtained by using grooved tube. The heat transfer coefficients for evaporation are correlated by the equation αE0=(Γ/D0)1/2. The substantial surface area, which is about three times larger than that of plane surfaced tube, is used in the above correlation.

  17. Thermal Properties of Loose Tube Secondary Coated Optical Fibres Experimentally Discussed by a Relative Light Pulse Delay Technique

    Science.gov (United States)

    1983-11-17

    mechanical stability of fibre optic cables for example, shrinkage of the extruded operating at varying ambient conditions, plastic tubes at elevated...heating process. Controlling the Fibre Excess Length In the design of fibre optic cables -- with respect to temperature characteri- stics, it should be

  18. Modelling and Multi-Variable Control of Refrigeration Systems

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Slot; Holm, J. R.

    2003-01-01

    In this paper a dynamic model of a 1:1 refrigeration system is presented. The main modelling effort has been concentrated on a lumped parameter model of a shell and tube condenser. The model has shown good resemblance with experimental data from a test rig, regarding as well the static as the dyn......In this paper a dynamic model of a 1:1 refrigeration system is presented. The main modelling effort has been concentrated on a lumped parameter model of a shell and tube condenser. The model has shown good resemblance with experimental data from a test rig, regarding as well the static...

  19. The Vienna Nuclear Demagnetization Refrigerator

    Science.gov (United States)

    Nguyen, D. H.; Sidorenko, A.; Müller, M.; Paschen, S.; Waard, A.; Frossati, G.

    2012-12-01

    A new nuclear demagnetization system coupled to a powerful dilution refrigerator and a vector magnet was successfully built and operated. Our aim was to construct a versatile, modular cryostat, with a large experimental space providing an excellent platform for various types of ultralow temperature measurements. A powerful dilution unit allows us to cool the mixing chamber down to 3 mK and to precool a massive copper (~90 mol) nuclear stage in a field of 9 T to 8 mK in 100 h. After demagnetization the lowest temperature of the copper stage measured by a Pt thermometer was 50.9 μK in a field of 20 mT. The cryostat is integrated with a 8 T-4 T vector magnet system. The refrigerator is provided with a 50 mm central clear shot tube allowing the insertion of a top-loading probe to cool down samples for measurements inside the vector magnet bore in a reasonably short time of about 4 hours. The system will be used to study quantum critical behavior of heavy fermion compounds.

  20. 120Hz单级脉管制冷机理论与实验%Therotical and experimental study on a 120 Hz single stage pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    甘智华; 吴英哲; 袁园; 邱利民; 张学军; 张小斌; 徐旭

    2011-01-01

    In order to study the characteristics of the high frequency regenerator and its influence to the performance of the pulse tube cryocooler, this paper optimized the geometry and operating parameters for the high frequency regenerator by using the numerical model, known as REGEN 3. 2. A Stirling type pulse tube cryocooler operating at 120 Hz was designed, fabricated and tested. This cryocooler achieves a no-load temperature of 47. 8 K, and can provide a cooling power of 8. 0 W at 78. 6 K. The result proves preliminarily that with higher frequency together with higher charging pressure, smaller hydraulic diameter and shorter regenerator, it is still possible to let the regenerator keep high efficiency. The experiment also indicated that this cryocooler can cool down fast and the pulse tube orientation effect was well suppressed benefiting from this higher frequency characteristic.%为了研究百赫兹以上的高频回热器的特性及其对脉管制冷机性能的影响,采用回热器数值计算程序RE-GEN3.2对高频回热器的尺寸参数和运行参数进行优化设计,并研制出一台运行频率为120 Hz的斯特林型脉管制冷机,其无负荷制冷温度为47.8 K,在78.6K有8.0W制冷量.初步证明配合使用更高的充气压力、采用小水力直径的回热填料以及缩短回热器长度,能够使得回热器在百赫兹以上的高频下仍然保持较高的效率.另外,实验显示该百赫兹高频脉管制冷机能够实现快速降温,脉管方向性问题也得到较好的抑制.

  1. The toxicity of refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-07-01

    This paper presents toxicity data and exposure limits for refrigerants. The data address both acute (short-term, single exposure) and chronic (long-term, repeated exposure) effects, with emphasis on the former. The refrigerants covered include those in common use for the last decade, those used as components in alternatives, and selected candidates for future replacements. The paper also reviews the toxicity indicators used in both safety standards and building, mechanical, and fire codes. It then outlines current classification methods for refrigerant safety and relates them to standard and code usage.

  2. Vibration-induced electrical noise in a cryogen-free dilution refrigerator: Characterization, mitigation, and impact on qubit coherence

    Science.gov (United States)

    Kalra, Rachpon; Laucht, Arne; Dehollain, Juan Pablo; Bar, Daniel; Freer, Solomon; Simmons, Stephanie; Muhonen, Juha T.; Morello, Andrea

    2016-07-01

    Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5-10 kHz range and its magnitude is found to be strongly temperature dependent. We test the performance of different cables designed to diagnose and tackle the noise, and find triboelectrics to be the dominant mechanism coupling the vibrations to the electrical signal. Flattening a semi-rigid cable or jacketing a flexible cable in order to restrict movement within the cable, successfully reduces the noise level by over an order of magnitude. Furthermore, we characterize the effect of the pulse tube vibrations on an electron spin qubit device in this setup. Coherence measurements are used to map out the spectrum of the noise experienced by the qubit, revealing spectral components matching the spectral signature of the pulse tube.

  3. Thermal decomposition of 1-chloropropane behind the reflected shock waves in the temperature range of 1015-1220 K: Single pulse shock tube and computational studies

    Indian Academy of Sciences (India)

    G Sudhakar; B Rajakumar

    2014-07-01

    The thermal decomposition of 1-chloropropane in argon was studied behind reflected shock waves in a single pulse shock tube over the temperature range of 1015-1220 K. The reaction mainly goes through unimolecular elimination of HCl. The major products observed in the decomposition are propylene and ethylene, while the minor products identified are methane and propane. The rate constant for HCl elimination in the studied temperature range is estimated to be k(1015-1220 K) = 1.63 × 1013exp(-(60.1 ± 1.0) kcal mol-1/RT) s-1. The DFT calculations were carried out to identify the transition state(s) for the major reaction channel; and rate coefficient for this reaction is obtained to be k(800-1500 K) = 5.01 × 1014exp(-(58.8) kcal mol-1/RT) s-1. The results are compared with the experimental findings.

  4. The dynamic single-tube concept; Le mono-tube dynamique

    Energy Technology Data Exchange (ETDEWEB)

    Rivet, P. [Ste MC International (France)

    1997-12-31

    In the framework of greenhouse gas emission reduction and the utilization of cooling intermediate fluids with indirect refrigerating systems, a new concept of dynamical single-tube has been developed, which allows for the simultaneous cold distribution from a centralized plant towards various required temperature systems (as for example in a supermarket refrigerating system) with optimized efficiency, fluid flow and defrosting conditions; moreover, the dynamic single-tube concept is very well adapted to two-phase flows

  5. Theoretical and experimental investigations on the optimal match between compressor and cold finger of the Stirling-type pulse tube cryocooler

    Science.gov (United States)

    Dang, Haizheng; Tan, Jun; Zhang, Lei

    2016-06-01

    The match between the pulse tube cold finger (PTCF) and the linear compressor of the Stirling-type pulse tube cryocooler plays a vital role in optimizing the compressor efficiency and in improving the PTCF cooling performance as well. In this paper, the interaction of them has been analyzed in a detailed way to reveal the match mechanism, and systematic investigations on the two-way matching have been conducted. The design method of the PTCF to achieve the optimal matching for the given compressor and the counterpart design method of the compressor to achieve the optimal matching for the given PTCF are put forward. Specific experiments are then carried out to verify the conducted theoretical analyses and modeling. For a given linear compressor, a new in-line PTCF which seeks to achieve the optimal match is simulated, designed and tested. And for a given coaxial PTCF, a new dual-opposed moving-coil linear compressor is also developed to match with it. The simulated and experimental results are compared, and fairly good agreements are found between them in both cases. The matched in-line cooler with the newly-designed PTCF has capacities of 4-11.84 W at 80 K with higher than 17% of Carnot efficiency and the mean motor efficiency of 81.5%, and the matched coaxial cooler with the new-designed compressor can provide 2-5.5 W at 60 K with higher than 9.6% of Carnot efficiency and the mean motor efficiency of 83%, which verify the validity of the theoretical investigations on the optimal match and the proposed design methods.

  6. Thermoacoustic engines and refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.

    1996-12-31

    This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

  7. Public Refrigerated Warehouses

    Data.gov (United States)

    Department of Homeland Security — The International Association of Refrigerated Warehouses (IARW) came into existence in 1891 when a number of conventional warehousemen took on the demands of storing...

  8. Thermoacoustic engines and refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.

    1996-12-31

    This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

  9. Anomalous Brownian Refrigerator

    OpenAIRE

    Rana, Shubhashis; Pal, P. S.; Saha, Arnab; Jayannavar, A. M.

    2015-01-01

    We present a detailed study of a Brownian particle driven by Carnot-type refrigerating protocol operating between two thermal baths. Both the underdamped as well as the overdamped limits are investigated. The particle is in a harmonic potential with time-periodic strength that drives the particle cyclically between the baths. Each cycle consists of two isothermal steps at different temperatures and two adiabatic steps connecting them. Besides working as a stochastic refrigerator, it is shown ...

  10. Refrigeration systems and applications

    CERN Document Server

    Dincer, Ibrahim

    2010-01-01

    Refrigeration Systems and Applications, 2nd edition offers a comprehensive treatise that addresses real-life technical and operational problems, enabling the reader to gain an understanding of the fundamental principles and the practical applications of refrigeration technology. New and unique analysis techniques (including exergy as a potential tool), models, correlations, procedures and applications are covered, and recent developments in the field are included - many of which are taken from the author's own research activities in this area. The book also includes so

  11. Refrigerated display cabinets; Butikskyla

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, Per

    2000-07-01

    This report summarizes experience from SP research and assignments regarding refrigerated transport and storage of food, mainly in the retail sector. It presents the fundamentals of heat and mass transfer in display cabinets with special focus on indirect systems and secondary refrigerants. Moreover, the report includes a brief account of basic food hygiene and the related regulations. The material has been compiled for educational purposes in the Masters program at Chalmers Technical University.

  12. Alumina shunt for precooling a cryogen-free 4He or 3He refrigerator

    Science.gov (United States)

    Uhlig, Kurt

    2016-10-01

    In this technical report a cryogen-free 1 K cryostat is described where the pot of the 4He refrigeration unit is precooled by the 2nd stage of a pulse tube cryocooler (PTC) from room temperature to T ∼ 3 K via a shunt made from sintered alumina (SA); the total mass of the 1 K stage is 3.5 kg. SA has high thermal conductivity at high temperatures; but below ∼50 K the thermal conductivity drops rapidly, almost following a T3-law. This makes SA an interesting candidate for the construction of a thermal shunt, especially as the heat capacity of metals drops by several orders of magnitude in the temperature range from 300 K to 3 K. At the base temperature of the PTC, the heat conduction of the shunt is so small that the heat leak into the 1 K stage is negligible.

  13. Experimental study on neon refrigeration system using commercial helium compressor

    Science.gov (United States)

    Ko, Junseok; Kim, Hyobong; Hong, Yong-Ju; Yeom, Hankil; Koh, Deuk-Yong; Park, Seong-Je

    2012-06-01

    In this study, we developed neon refrigeration system using commercial helium compressor which was originally designed for GM cryocooler. We performed this research as precedent study before developing neon refrigeration system for small-scale hydrogen liquefaction system. The developed system is based on precooled Linde-Hampson system with liquid nitrogen as precoolant. Design parameters of heat exchangers are determined from thermodynamic cycle analysis with operating pressure of 2 MPa and 0.4 MPa. Heat exchangers have concentric-tube heat exchanger configuration and orifice is used as Joule- Thomson expansion device. In experiments, pressure, temperature, mass flow rate and compressor input power are measured as charging pressure. With experimental results, the characteristics of heat exchanger, Joule-Thomson expansion and refrigeration effect are discussed. The developed neon refrigeration system shows the lowest temperature of 43.9 K.

  14. Ferromagnetic Tubes Testing Based Pulsed Remote Field Eddy Current Technique%基于脉冲远场涡流的管道内检测技术

    Institute of Scientific and Technical Information of China (English)

    杨理践; 王赓; 高松巍

    2012-01-01

    针对传统远场涡流检测方法对铁磁性管道内外壁缺陷灵敏度相同,无法有效区分缺陷在管道内壁还是管道外表面的问题,提出了采用具有丰富频率成分的脉冲激励信号取代传统的远场涡流中正弦信号激励的方法.采用小波去噪方法滤除检测数据中的信号噪声;研究了将检测线圈分别置于近场区、过渡区和远场区时的信号时域特性与管壁伤的关系;进行了针对管道管壁内外相同宽度不同深度缺陷的检测试验,结果表明采用脉冲激励作为激励源并综合运用过渡区的检测信号的幅值和过零时间特征能够有效地区分管壁内外全周向的缺陷.%In view of the traditional remote field eddy current technique for ferromagnetic tube having the same sensitivity of inner and outside walls defect,unable to distinguish the defects in the inner wall or in the outer surface,this paper adopt with abundant frequency components of the pulse signal to replace the traditional remote field eddy current sinusoidal excitation signal. Using the methods of wavelet denoising to filter acquired signal and process the data. This paper studied the relationship between the tube wall defects and signal time-domain characteristics when the detector coil was placed in the direct zone, transition zone and remote field zone. Conduct experiments to acquire data about different depth defects in the inside or outside of the walls, the results show that using the pulse signal as excitation source and characteristics about the detect signal amplitude and zero-crossing time can effectively distinguish between the inner and outer circumferential direction tube wall defects.

  15. Cavity-enhanced absorption spectroscopy with a ps-pulsed UV laser for sensitive, high-speed measurements in a shock tube.

    Science.gov (United States)

    Wang, Shengkai; Sun, Kai; Davidson, David F; Jeffries, Jay B; Hanson, Ronald K

    2016-01-11

    We report the first application of cavity-enhanced absorption spectroscopy (CEAS) with a ps-pulsed UV laser for sensitive and rapid gaseous species time-history measurements in a transient environment (in this study, a shock tube). The broadband nature of the ps pulses enabled instantaneous coupling of the laser beam into roughly a thousand cavity modes, which grants excellent immunity to laser-cavity coupling noise in environments with heavy vibrations, even with an on-axis alignment. In this proof-of-concept experiment, we demonstrated an absorption gain of 49, which improved the minimum detectable absorbance by ~20 compared to the conventional single-pass strategy at similar experimental conditions. For absorption measurements behind reflected shock waves, an effective time-resolution of ~2 μs was achieved, which enabled time-resolved observations of transient phenomena, such as the vibrational relaxation of O(2) demonstrated here. The substantial improvement in detection sensitivity, together with microsecond measurement resolution implies excellent potential for studies of transient physical and chemical processes in nonequilibrium situations, particularly via measurements of weak absorptions of trace species in dilute reactive systems.

  16. 低温脉管制冷机的热力学性能和损失计算%Thermodynamic analysis and loss calculation of four valve pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    王坤; 鲁雪生; 顾安忠

    2013-01-01

    Some theoretical analysis methods for pulse tube cryocooler were firstly introduced in this essay,then thermodynamic calculation used in this essay was described.The thermodynamic result of the thermodynamic calculation on a four valve pulse tube cryocooler with fixed size was shown.We can conclude from the the analysis of the results:valve loss is the main loss of the four valve pulse tube cryocooler,thin-thickness of pulse tube will be the main way to improve the performance of the cryocooler.%首先简要介绍了目前的一些对于脉管制冷机的理论分析方法以及各种损失分析计算,接着针对某尺寸的四阀型脉管制冷机,考虑到不同厚度的脉管对其的影响,结合两种厚度的脉管进行热力计算和损失分析,分析结果表明,四阀型脉管制冷机的主要损失在于阀门处,进一步降低阀门损失将是提高制冷机性能的主要手段.

  17. Development and experimental study of a miniature vapor compression refrigeration equipment

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A miniature vapor compression refrigeration equipment prototype was developed for a range of microclimate control applications, including man portable cooling and distributed space conditioning. The miniature refrigeration equipment has dimensions of 260 mm × 250 mm × 120 mm, and weighs approximately 2.85 kg. The optimal motor and its transmission ratio, the optimal dimension of capillary tube and the optimal quantity of refrigerant charge were obtained by matching and operating performance experimental study. Experimental results show that the miniature refrigeration equipment can provide 300 W cooling, and its COPc is above 2.0.

  18. Development and experimental study of a miniature vapor compression refrigeration equipment

    Institute of Scientific and Technical Information of China (English)

    ZHONG XiaoHui; GOU YuJun; WU YuTing; MA ChongFang

    2008-01-01

    A miniature vapor compression refrigeration equipment prototype was developed for a range of microclimate control applications,including man portable cooling and distributed space conditioning.The miniature refrigeration equipment has di-mensions of 260 mm×250 mm×120 mm,and weighs approximately 2.85 kg.The optimal motor and its transmission ratio,the optimal dimension of capillary tube and the optimal quantity of refrigerant charge were obtained by matching and op-erating performance experimental study.Experimental results show that the miniature refrigeration equipment can provide 300 W cooling,and its COPc is above 2.0.

  19. Miscibility comparison for three refrigerant mixtures and four component refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Kang, H.M.; Pate, M.B.

    1999-07-01

    Miscibility data were taken and compared for seven different refrigerants when mixed with the same polyol ester (POE) lubricant. Four of the seven refrigerants were single-component refrigerants while three of the refrigerants were mixtures composed of various combinations of the pure refrigerants. The purpose of this research was to investigate the difference in miscibility characteristics between refrigerant mixtures and their respective component refrigerants. The POE lubricant was a penta erythritol mixed-acid type POE which has a viscosity ISO32. The four pure refrigerants were R-32, R-125, R-134a, and R-143a and the three refrigerant mixtures were R-404A, R407C, and R-410A. The miscibility tests were performed in a test facility consisting of a series of miniature test cells submerged in a constant temperature bath. The test cells were constructed to allow for complete visibility of the refrigerant/lubricant mixtures under all test conditions. The tests were performed over a concentration range of 0 to 100% and a temperature range of {minus}40 to 194 F. The miscibility test results for refrigerant mixtures are compared to component refrigerants. In all cases, the refrigerant mixtures appear to have better miscibility than their most immiscible pure component.

  20. Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Vishaldeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Environmental concerns are driving regulations for the heating, ventilating, air-conditioning and refrigeration (HVAC&R) industry towards lower GWP alternatives to HFC refrigerants. Existing lower GWP refrigerant alternatives include hydrocarbons, such as propane (R-290) and isobutane (R-600a), as well as carbon dioxide (R-744), ammonia (R-717), and R-32. In addition, new lower GWP refrigerant alternatives are currently being developed by refrigerant manufacturers, including hydrofluoro-olefin (HFO) and unsaturated hydrochlorofluorocarbon (HCFO) refrigerants. The selection of an appropriate refrigerant for a given refrigeration application should be based on several factors, including the GWP of the refrigerant, the energy consumption of the refrigeration system over its operating lifetime, and leakage of refrigerant over the system lifetime. For example, focusing on energy efficiency alone may overlook the significant environmental impact of refrigerant leakage; while focusing on GWP alone might result in lower efficiency systems that result in higher indirect impact over the equipment lifetime. Thus, the objective of this Collaborative Research and Development Agreement (CRADA) between

  1. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

    1993-04-30

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

  2. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Cain, J.M. [Calm (James M.), Great Falls, VA (United States)

    1993-04-30

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

  3. Dry Dilution Refrigerator with He-4 Precool Loop

    CERN Document Server

    Uhlig, K

    2014-01-01

    He-3/He-4 dilution refrigerators (DR) are very common in sub-Kelvin temperature research. We describe a pulse tube precooled DR where a separate He-4 circuit condenses the He-3 of the dilution loop. Whereas in our previous work the dilution circuit and the He-4 circuit were separate, we show how the two circuits can be combined. Originally, the He-4 loop with a base temperature of ~ 1 K was installed to make an additional cooling power of up to 100 mW available to cool cold amplifiers and electrical lines. In the new design, the dilution circuit is run through a heat exchanger in the vessel of the He-4 circuit so that the condensation of the He-3 stream of the DR is done by the He-4 stage. A much reduced condensation time (factor of 2) of the He-3/He-4 gas mixture at the beginning of an experiment is achieved. A compressor is no longer needed with the DR as the condensation pressure remains below atmospheric pressure at all times; thus the risk of losing expensive He-3 gas is small. The performance of the DR ...

  4. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1992-11-09

    The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

  5. Refrigeration a history

    CERN Document Server

    Gantz, Carroll

    2015-01-01

    For thousands of years, humans coped with heat by harvesting and storing natural ice and devising natural cooling systems that utilized ventilation and evaporation. By the mid 1800s, people began developing huge refrigeration machines to manufacture ice. By the early 1900s, engineers developed electric domestic refrigerators, which by 1927 were affordable convenient household appliances. By then, an increasingly sophisticated public demanded more modern-looking appliances than engineers could produce, and a new breed of designers entered the manufacturing world to provide them. During the Depr

  6. Energy efficiency in refrigerated transport

    NARCIS (Netherlands)

    Gerwen, R.J.M. van; Sluis, S.M. van der; Schiphouwer, H.

    1998-01-01

    In refrigerated road transport, 10 to 40 `)/0 of the total energy consumption is related to refrigeration. However, energy consumption and energy efficiency of refrigerated transport equipment is rarely mentioned in the discussions about energy saving, potentials in road transport. Two main approach

  7. Exergy analysis of magnetic refrigeration

    CERN Document Server

    Lucia, Umberto

    2010-01-01

    One of the main challenges of the industry today is to face its impact on global warming considering that the greenhouse effect problem is not be solved completely yet. Magnetic refrigeration represents an environment-safe refrigeration technology. The magnetic refrigeration is analysed using the second law analysis and introducing exergy in order to obtain a model for engineering application.

  8. The vapor compression refrigeration cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pannkoke, T.

    1995-11-01

    This article is a review of the basic principles of a cycle widely used to create the refrigeration effect that provides both human comfort and process cooling. While a semantic differentiation often is made for cooling and dehumidifying air for human comfort (air conditioning) and cooling for products and processes (refrigeration), all mechanical cooling applications depend on the previously mentioned refrigeration effect.

  9. Refrigeration Playbook: Natural Refrigerants; Selecting and Designing Energy-Efficient Commercial Refrigeration Systems That Use Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Caleb [CTA Architects Engineers, Boise, ID (United States); Reis, Chuck [CTA Architects Engineers, Boise, ID (United States); Nelson, Eric [CTA Architects Engineers, Boise, ID (United States); Armer, James [CTA Architects Engineers, Boise, ID (United States); Arthur, Rob [CTA Architects Engineers, Boise, ID (United States); Heath, Richard [CTA Architects Engineers, Boise, ID (United States); Rono, James [CTA Architects Engineers, Boise, ID (United States); Hirsch, Adam [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doebber, Ian [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    This report provides guidance for selecting and designing energy efficient commercial refrigeration systems using low global warming potential refrigerants. Refrigeration systems are generally the largest energy end use in a supermarket type building, often accounting for more than half of a building's energy consumption.

  10. Condensation heat transfer of r134a for single tubes and tube bundles using standard and high performance finned tubes; Kondensatseitiger Waermeuebergang am Einzelrohr und im Rohrbuendel beim Einsatz von Standard- und Hochleistungsrippenrohren mit R134a

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, Thomas; Leipertz, Alfred; Froeba, Andreas Paul [Erlangen-Nuernberg Univ. (Germany). Lehrstuhl fuer Technische Thermodynamik; Gotterbarm, Achim; El Hajal, Jean; Beutler, Andreas [Wieland-Werke AG, Ulm (Germany)

    2011-08-15

    This work aims at the optimization of the heat transfer of refrigerant R134a on finned tubes in shell-and-tube condensers. The coating and optimization of the fin structure should increase the drainage of the condensate in the space between the fins and therefore the condensation heat transfer on single tubes and tube bundles. (orig.)

  11. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    2017-08-08

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  12. Refrigerating machine operating characteristics under various mixed refrigerant mass charges

    Energy Technology Data Exchange (ETDEWEB)

    Rozhentsev, Andrey [Far Eastern State Transport University of the Russian Federation, Seryshev street, 47, 680021 Khabarovsk (Russian Federation)

    2008-11-15

    This paper reports the results of experimental investigation of a low-temperature Joule-Thomson refrigerating machine, working by use of a non-azeotropic mixture of refrigerants and with a single-stage hermetic compressor. The temperature, hydraulic and power performance of the machine are determined experimentally in relation to the mixed refrigerant (MR) mass charge. Variations of the MR refrigerating machine operating performance with the working mixture mass charge are found to be considerably different from the analogous performance variations of a refrigerating machine charged with a pure refrigerant. The peculiarities of those relationships are analyzed theoretically. The specific value of a minimum acceptable MR mass charge for the investigated system and its correlation with internal processes in the machine loop are established as well. If the refrigerant mixture mass charges are below the minimum ones, the temperature and power performance of the MR machine differ essentially from the design performance and such operating modes are considered inadmissible. (author)

  13. Effect of evaporator temperature on vapor compression refrigeration system

    Directory of Open Access Journals (Sweden)

    Abdullah A.A.A. Al-Rashed

    2011-12-01

    Full Text Available This paper presents a comparable evaluation of R600a (isobutane, R290 (propane, R134a, R22, for R410A, and R32 an optimized finned-tube evaporator, and analyzes the evaporator effect on the system coefficient of performance (COP. Results concerning the response of a refrigeration system simulation software to an increase in the amount of oil flowing with the refrigerant are presented. It is shown that there is optima of the apparent overheat value, for which either the exchanged heat or the refrigeration coefficient of performance (COP is maximized: consequently, it is not possible to optimize both the refrigeration COP and the evaporator effect. The obtained evaporator optimization results were incorporated in a conventional analysis of the vapor compression system. For a theoretical cycle analysis without accounting for evaporator effects, the COP spread for the studied refrigerants was as high as 11.7%. For cycle simulations including evaporator effects, the COP of R290 was better than that of R22 by up to 3.5%, while the remaining refrigerants performed approximately within a 2% COP band of the R22 baseline for the two condensing temperatures considered.

  14. Experimental study on in-tube condensation heat transfer characteristics of helically coiled spiral tubes

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.U. [Sunchon First College, Sunchon (Korea); Kweon, Y.C. [Sun Moon University, Chonan (Korea); Han, K.I. [Pukyong National University, Pusan (Korea)

    2001-12-01

    An experimental study on condensation heat transfer characteristics of helically coiled spiral tubes was performed. The refrigerant is R-113. A refrigerant loop was established to measure the condensation heat transfer coefficients. Experiments were carried out uniform heat flux of 15 kW/m{sup 2}, refrigerant quality of 0.1 {approx} 0.9, curvature ratio of 0.016, 0.025 and 0.045. The curvature of a coil was defined as the ratio of the inside diameter of the tube to the diameter of the bending circle. To compare the condensation heat transfer coefficients of coiled spiral tubes, the previous results on coiled plain tubes and straight plain tubes were used. The results shows that the condensation heat transfer coefficients of coiled spiral tubes largely increase, as increasing Re and quality, compared to those of coiled plain tubes and straight plain tubes. As increasing degree of subcooling, however, the condensation heat transfer coefficients on coiled spiral tubes decrease. It is found that the heat transfer enhancement is more better than coiled plain tubes and straight plain tubes, as increasing curvature ratio. (author). 13 refs., 10 figs., 1 tab.

  15. Heat Transfer Performance of Absorber of Absorption Refrigerating Machine

    Science.gov (United States)

    Kunugi, Yoshifumi; Ouchi, Tomihisa; Usui, Sanpei; Fukuda, Tamio

    Experimental studies on heat transfer performance of absorber for lithium bromide-water absorption refrigerating machine are presented in this paper. Experimental apparatus for 35 kW evaporator and absorber, and outer grooved tubes are used. As a result, over-al1 coefficient of heat transmission of absorber has a maximum value, in the case of heat transfer area ratio of absorber to evaporator, is about 0.8. Heat transfer rate of absorber is increased by 60% by using the outer grooved tube compared with the plane surfaced tube.

  16. Trends in the development of fluid-operated heat transfer devices for refrigerant feed pumps and heat pumps using non-azeotropic binary-fluid refrigerants with special regard to the problem of CFCs. Entwicklungstendenzen fluessigkeitsbeaufschlagter Waermeuebertrager fuer Kaelte- und Waermepumpenanlagen mit nichtazeotropen Zweistoffkaeltemitteln unter Beruecksichtigung der FCKW-Problematik

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, F.

    1991-06-12

    In the construction of binary-fluid refrigerant heat transfer devices as evaporators and condensers in heat pumps for the cooling of waste heat flows, the hydraulic diametre of the media flows is decisive. By means of the flow against refrigerant-carrying tubes, heat transfer systems can be assigned to different categories. The heat transfer in a heat exchanger is determined by quantities such as water speed and flow conditions in refrigerant-carrying tubes. (VT)

  17. Design of a Dry Dilution Refrigerator for MMC Gamma Detector Arrays

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Stephan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Boyd, Stephen [Univ. of New Mexico, Albuquerque, NM (United States); Cantor, Robin

    2017-04-03

    The goal of this LCP is to develop an ultra-high resolution gamma detector based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material to replace current Au:Er sensors. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers. MMC detectors require operating temperatures of ~15 mK and thus the use of a dilution refrigerator, and the desire for user-friendly operation without cryogenic liquids requires that this refrigerator use pulse-tube pre-cooling to ~4 K. For long-term reliability, we intend to re-design the heat switch that is needed to apply the magnetizing current to the Ag:Er sensor and that used to fail in earlier designs after months of operation. A cryogenic Compton veto will be installed to reduce the spectral background of the MMC, especially at low energies where ultra-high energy resolution is most important. The goals for FY16 were 1) to purchase a liquid-cryogen-free dilution refrigerator and adapt it for MMC operation, and 2) to fabricate Ag:Er-based MMC γ-detectors with improved performance and optimize their response. This report discusses the design of the instruments, and progress in MMC detector fabrication. Details of the MMC fabrication have been discussed in an April 2016 report to DOE.

  18. Investigations on a Thermoacoustic Refrigerator

    CERN Document Server

    Dhuley, Ram C

    2016-01-01

    Thermoacoustic Refrigerators use acoustic power for generating cold temperatures. Development of refrigerators based on the thermoacoustic technology is a novel solution to the present day need of cooling, without causing environmental hazards. With added advantages such as minimal moving parts and absence of CFC refrigerants, these devices can attain low temperatures maintaining a compact size. The present work describes an in-depth theoretical analysis of standing wave thermoacoustic refrigerators. This consists of detailed parametric studies, transient state analysis, and a design using an available simulation software. Design and construction of a thermoacoustic refrigerator using a commercially available electro-dynamic motor is also presented.

  19. Fundamentals of Refrigeration.

    Science.gov (United States)

    Sutliff, Ronald D.; And Others

    This self-study course is designed to familiarize Marine enlisted personnel with the principles of the refrigeration process. The course contains five study units. Each study unit begins with a general objective, which is a statement of what the student should learn from the unit. The study units are divided into numbered work units, each…

  20. Education in Helium Refrigeration

    Science.gov (United States)

    Gistau Baguer, G. M.

    2004-06-01

    On the one hand, at the end of the time I was active in helium refrigeration, I noticed that cryogenics was stepping into places where it was not yet used. For example, a conventional accelerator, operating at room temperature, was to be upgraded to reach higher particle energy. On the other hand, I was a little bit worried to let what I had so passionately learned during these years to be lost. Retirement made time available, and I came gradually to the idea to teach about what was my basic job. I thought also about other kinds of people who could be interested in such lessons: operators of refrigerators or liquefiers who, often by lack of time, did not get a proper introduction to their job when they started, young engineers who begin to work in cryogenics… and so on. Consequently, I have assembled a series of lessons about helium refrigeration. As the audiences have different levels of knowledge in the field of cryogenics, I looked for a way of teaching that is acceptable for all of them. The course is split into theory of heat exchangers, refrigeration cycles, technology and operation of main components, process control, and helium purity.

  1. Pressure drop characteristics of cryogenic mixed refrigerant at macro and micro channel heat exchangers

    Science.gov (United States)

    Baek, Seungwhan; Jeong, Sangkwon; Hwang, Gyuwan

    2012-12-01

    Mixed Refrigerant-Joule Thomson (MR-JT) refrigerators are widely used in various kinds of cryogenic systems these days. The temperature glide effect is one of the major features of using mixed refrigerants since a recuperative heat exchanger in a MR-JT refrigerator is utilized for mostly two-phase flow. Although a pressure drop estimation for a multi-phase and multi-component fluid in the cryogenic temperature range is necessarily required in MR-JT refrigerator heat exchanger designs, it has been rarely discussed so far. In this paper, macro heat exchangers and micro heat exchangers are compared in order to investigate the pressure drop characteristics in the experimental MR-JT refrigerator operation. The tube in tube heat exchanger (TTHE) is a well-known macro-channel heat exchanger in MR-JT refrigeration. Printed Circuit Heat Exchangers (PCHEs) have been developed as a compact heat exchanger with micro size channels. Several two-phase pressure drop correlations are examined to discuss the experimental pressure measurement results. The result of this paper shows that cryogenic mixed refrigerant pressure drop can be estimated with conventional two-phase pressure drop correlations if an appropriate flow pattern is identified.

  2. 脉冲管制冷机混合填充式蓄冷器的实验研究%Experiment study of multi-mesh fill regenerator for pulse tube cryocooler

    Institute of Scientific and Technical Information of China (English)

    张安阔; 陈曦; 吴亦农; 张华; 杨开响

    2013-01-01

    基于脉冲管制冷机蓄冷器结构,提出了#400不锈钢丝网以及其与#300和#500组合而成的混合式蓄冷器填充方式.通过构建一单级分体式脉冲管制冷机测试平台,将#400及混合目数丝网分别填充至制冷机蓄冷器内进行整机实验,实验结果验证了低温制冷机蓄冷器冷热端分别填充高低目数丝网,可提高制冷机性能,是一种有效的蓄冷器优化方法.%Based on a regenerator structure of a pulse tube cryocooler, it was proposed that #400 stainless steel meshes screen and the combination of #300 or #500 with #400 could be filled into the pulse tube cryocooler regenerator respectively. A test platform was built for testing a single-stage pulse tube cryocooler, the #400 or the combinative meshes screen could be tested in its regenerator. Experiments were done and results showed that it was an effective optimization method to fill different meshes at the warm and cold ends of the cryocooler regenerator, which could improve the efficiency of the whole cryocooler.

  3. Determination of a Vapor Compression Refrigeration System Refrigerant Charge

    Institute of Scientific and Technical Information of China (English)

    YangChun-Xin; DangChao-Bin

    1995-01-01

    A physical model is established in this paper to describe the heat transfer and two phase flow of a refrigerant in the evaporator and condenser of a vapor compression refrigeration system.The model in then used to determine the refrigerant charge in vapor compression units.The model is used for a sensitivity analysis to determine the effect that varing design parameters on the refrigerant charge,The model is also used to evaluate the effect of refrigerant charge and the thermal physical properties on the refrigeration cycle,The predicted value of the refigerant charge and experimental data agree well The model and the method presented in this paper could be used to design vapour compression units such as domestic refrigeratirs and air conditioners.

  4. Ear Tubes

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Ear Tubes Ear Tubes Patient Health Information News media ... and throat specialist) may be considered. What are ear tubes? Ear tubes are tiny cylinders placed through ...

  5. A Case Study of a Low Powervapour Compression Refrigeration System

    Science.gov (United States)

    Abinav, R.; Nambiar, G. K.; Sahu, Debjyoti

    2016-09-01

    Reported in this paper is a case study on a normal vapor compression refrigeration system which is expected to be run by photovoltaic panels to utilize minimum grid power. A small 120 W refrigerator is fabricated out of commercially available components and run by an inverter and battery connected to solar photovoltaic panel as well as grid. Temperature at several points was measured and the performance was evaluated. The Coefficient of performance (COP) to run such refrigerator is estimated after numerical simulation of major components namely, evaporator, condenser and a capillary tube. The simulation was done to obtain an effective cooling temperature and the results were compared with measured temperatures. Calculation proves to be in conformity with the actual model.

  6. Superfluid thermodynamic cycle refrigerator

    Science.gov (United States)

    Swift, Gregory W.; Kotsubo, Vincent Y.

    1992-01-01

    A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

  7. Operating characteristics of a single-stage Stirling-type pulse tube cryocooler with high cooling power at liquid nitrogen temperatures

    Institute of Scientific and Technical Information of China (English)

    Jiu-ce SUN; Marc DIETRICH; Li-min QIU; Guenter THUMMES

    2015-01-01

    The operating characteristics are important for design and optimization of pulse tube cryocoolers, in particular for those with high cooling power, which up to now have been seldom extensively investigated. In this study, the dependence of cooling performance on the charge pressure and operating frequency has been investigated, both numerically and experimentally. A numerical model based on Sage software was established. Experiments were performed on a home-made single-stage high power Stirling-type pulse tube cryocooler (SPTC) working at liquid nitrogen temperatures. The results revealed that each charge pressure corresponds to an optimum frequency with respect to compressor and regenerator efficiency. A lower charge pressure results in a higher cryocooler efficiency, but the delivered maximum pV power is significantly reduced due to the stroke limit of the pistons in the linear compressor. The influence of operating characteristics on the temperature non-uniformity in the regener-ator was also investigated. By optimizing the charge pressure and frequency, the minimum no-load temperature was decreased to 46.9 K at 56.5 Hz and 2.0 MPa. A cooling power of 300 W at 71.8 K was measured with an electrical input power of 8.9 kW.%题目:液氮温区单级大功率斯特林型脉管制冷机工作特性研究  目的:探索充气压和运行频率等工作特性对大功率脉管制冷机最低制冷温度、制冷量以及回热器温度不均匀性的影响,期望进一步提升制冷机工作性能。  方法:1.通过理论计算模拟工作频率在40–70 Hz,充气压力在1.5–2.5 MPa下工作特性对制冷机性能的影响;2.实验研究充气压力为1.7–2.4 MPa,并在谐振频率附近工作时制冷机性能以及回热器温度不均匀性随充气压力、运行频率以及输入功率的变化。  结论:1.制冷机运行在1.9–2.1 MPa充气压力下,因平衡了制冷温度和焓流损失,故能取得优异性能,且

  8. Multilayer Thermionic Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Mahan, G.D.

    1999-08-30

    A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

  9. Autonomous solar refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Bougard, J.; Vokaert, D. (Faculte Polytechnique de Mons, Universite Libre de Bruxelles (Belgium))

    1982-11-01

    A compression refrigerator, fed by a flat solar pannel and composed of two thermal machines, working on a Rankine-Hirn cycle, is described. Mechanical energy is transferred by a double effect free-piston which is at the same time engine, pump, compressor and electric generator for auxiliaries. Freon R12 or R114 is used as the working fluid. Performances of a prototype are given. Investment for a classical unit, fed by a photovoltaic pannel would be more than twice.

  10. Reactions of 1-naphthyl radicals with acetylene. Single-pulse shock tube experiments and quantum chemical calculations. Differences and similarities in the reaction with ethylene.

    Science.gov (United States)

    Lifshitz, Assa; Tamburu, Carmen; Dubnikova, Faina

    2009-10-01

    The reactions of 1-naphthyl radicals with acetylene were studied behind reflected shock waves in a single-pulse shock tube, covering the temperature range 950-1200 K at overall densities behind the reflected shocks of approximately 2.5 x 10(-5) mol/cm3. 1-Iodonaphthalene served as the source for 1-naphthyl radicals. The [acetylene]/[1-iodonaphthalene] ratio in all of the experiments was approximately 100 to channel the free radicals into reactions with acetylene rather than iodonaphthalene. Only two major products resulting from the reactions of 1-naphthyl radicals with acetylene and with hydrogen atoms were found in the post shock samples. They were acenaphthylene and naphthalene. Some low molecular weight aliphatic products at rather low concentrations, resulting from an attack of various free radicals on acetylene, were also found in the shocked samples. In view of the relatively low temperatures employed in the present experiments, the unimolecular decomposition rate of acetylene is negligible. One potential energy surface describes the production of acenaphthylene and 1-naphthyl acetylene, although the latter was not found experimentally due to the high barrier (calculated) required for its production. Using quantum chemical methods, the rate constants for three unimolecular elementary steps on the surface were calculated using transition state theory. A kinetics scheme containing 16 elementary steps was constructed, and computer modeling was performed. An excellent agreement between the experimental yields of the two major products and the calculated yields was obtained. Differences and similarities in the potential energy surfaces of 1-naphthyl radical + acetylene and those of ethylene are presented, and the kinetics mechanisms are discussed.

  11. Japanese activities in refrigeration technology

    Science.gov (United States)

    Fujita, T.; Ohtsuka, T.; Ishizaki, Y.

    This paper reviews recent activities in refrigeration technology in Japan. The projects described are stimulated by growing industrial needs or form part of large national projects. The JNR project on the MAGLEV train is currently the most powerful activity and it demands knowledge in all the different disciplines of cryogenics in particular on various scales of refrigeration. Research activities are also directed towards the development of Stirling cycle and magnetic refrigerators for applications in a wider area.

  12. ALTERNATIVE REFRIGERANT R-134A

    Directory of Open Access Journals (Sweden)

    Rasim KARABACAK

    1997-03-01

    Full Text Available Because of the big damages on the ozone layer given by the refrigerants cloroflorocarbons that has been used up to now, new alternative gases should be developped and product at once. In this study, some informations about alternative to presently used CFCs, R-134A refrigerant's characteristics and its suitability to cooling systems is given. As it would be understood from these informations there is no objection on using alternative R-134A refrigerant

  13. Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

    Directory of Open Access Journals (Sweden)

    CHENNUCHETTY CHINNARAJ,

    2010-09-01

    Full Text Available A window air conditioner of 3.5 K.W capacity fitted with expansion devices such as capillary tube, thermostatic expansion valve and Electronic expansion valve was tested for its coefficient of performance, power required and refrigeration effect with respect to the refrigerants R22 and R407C under different operating conditions .Initially evaporator temperature was maintained at 279 K and condenser temperature was varied and then the test was conducted again in the same window air conditioner with electronic expansion valve alone as expansion device and by varying the refrigerant super heat temperature at inlet to the compressor from 273K to 293K for the refrigerants R 22, R 407C and R 290 The performance of electronic expansion valve with eco friendly refrigerants shows a positive effect and enable the industry to favorably displace the R22 and other types of expansion devices.

  14. Experimental performance evaluation of heat pump by using CO2 as a refrigerant

    Science.gov (United States)

    Venkatesh, V. K.; Basavaraju, M. G.; Sreenivas Rao, K. V.

    2016-09-01

    In this experiment the refrigerant used is CO2 which is naturally available, eco friendly, economical, non toxic, non flammable and non corrosive. Its Ozone Depletion Potential (ODP) is zero and minimum Global Warming Potential (GWP). The performance evaluation of prototype vapor compression heat pump model was performed and evaluated the different parameters like COP (Co-efficient of performance), LMTD (Logarithmic mean temperature difference) and outlet water temperature of condenser. The experiment is carried out for two different condensers by varying mass flow rate and pressure. The water in the shell side was heated by absorbing heat from refrigerants in the tube side of condensers by counter flow heat exchanging method. The experimental result indicates fairly good COP with the use of CO2 refrigerant. These advantages of CO2 as a refrigerant favors the replacement for globally used refrigerant with CO2.

  15. Regulating Power from Supermarket Refrigeration

    DEFF Research Database (Denmark)

    O'Connell, Niamh; Madsen, Henrik; Pinson, Pierre

    2014-01-01

    This paper presents an analysis of the demand response capabilities of a supermarket refrigeration system, with a particular focus on the suitability for participation in the regulating power market. An ARMAX model of a supermarket refrigeration system is identified using experimental data from...... nature of demand response from refrigeration is identified as the key consideration when considering participation in the regulating power market. It is demonstrated that by restricting the operating regions of the supermarket refrigeration system, a simple relationship can be found between the available...

  16. THERMODYNAMIC PROPERTIES OF SELECTED HFC REFRIGERANTS

    Science.gov (United States)

    Hydrofluorocarbon (HFC) refrigerants are possible alternatives to replace ozone-depleting chlorofluorocarbon and hydrochlorofluorocarbon (HCFC) refrigerants. The flammability of a proposed new refrigerant is a major consideration in assessing its utility for a particular applicat...

  17. Regeneration tests of a room temperature magnetic refrigerator and heat pump

    CERN Document Server

    Brown, G V

    2014-01-01

    A magnetic heat pump apparatus consisting of a solid magnetic refrigerant, gadolinium, and a liquid regenerator column of ethanol and water has been tested. Utilizing a 7T field, it produced a maximum temperature span of 80 K, and in separate tests, a lowest temperature of 241 K and a highest temperature of 328 K. Thermocouples, placed at intervals along the regenerator tube, permitted measurement of the temperature distribution in the regenerator fluid. No attempt was made to extract refrigeration from the device, but analysis of the temperature distributions shows that 34 watts of refrigeration was produced.

  18. Vibration-induced electrical noise in a cryogen-free dilution refrigerator: characterization, mitigation, and impact on qubit coherence

    CERN Document Server

    Kalra, Rachpon; Dehollain, Juan P; Bar, Daniel; Freer, Solomon; Simmons, Stephanie; Muhonen, Juha T; Morello, Andrea

    2016-01-01

    Cryogen-free low-temperature setups are becoming more prominent in experimental science for their convenience, reliability and the increasing scarcity of helium as a natural resource. Despite not having any moving parts at the cold end, pulse tube cryocoolers introduce vibrations that can be detrimental to the experiments. We characterize the coupling of these vibrations to the electrical signal observed on cables installed in a cryogen-free dilution refrigerator. The dominant electrical noise is in the 5 to 10 kHz range and its magnitude is found to be strongly temperature dependent. We test the performance of different cables designed to diagnose and tackle the noise, and find triboelectrics to be the dominant mechanism coupling the vibrations to the electrical signal. Flattening a semi-rigid cable or jacketing a flexible cable in order to restrict movement within the cable, successfully reduces the noise level by over an order of magnitude. Furthermore, we characterize the effect of the pulse tube vibratio...

  19. Cycling Joule Thomson refrigerator

    Science.gov (United States)

    Tward, E.

    1983-01-01

    A symmetrical adsorption pump/compressor system having a pair of mirror image legs and a Joule Thomson expander, or valve, interposed between the legs thereof for providing a, efficient refrigeration cycle is described. The system further includes a plurality of gas operational heat switches adapted selectively to transfer heat from a thermal load and to transfer or discharge heat through a heat projector, such as a radiator or the like. The heat switches comprise heat pressurizable chambers adapted for alternate pressurization in response to adsorption and desorption of a pressurizing gas confined therein.

  20. Energy optimisation of domestic refrigerators

    DEFF Research Database (Denmark)

    Jakobsen, Arne; Rasmussen, Bjarne D.

    1998-01-01

    This paper describes the main results of a research project with the objective of reducing the energy consumption of domestic refrigerators by increasing the efficiency of the refrigeration system. The improvement of the system efficiency was to be obtained by:1) Introducing continuous operation...

  1. Study on wave rotor refrigerators

    Institute of Scientific and Technical Information of China (English)

    Yuqiang DAI; Dapeng HU; Meixia DING

    2009-01-01

    As a novel generation of a rotational gas wave machine, the wave rotor refrigerator (WRR) is an unsteady flow device used for refrigeration, in whose passages pressured streams directly contact and exchange energy due to the movement of pressure waves. In this paper, the working mechanism and refrigeration principle are inves-tigated based on the one-dimensional unsteady flow theory.A basic limitation on main structural parameters and operating parameters is deduced and the wave diagram of WRR to guide designing is sketched. The main influential factors are studied through an experiment. In the DUT Gas Wave Refrigeration Studying and Development Center (GWRSDC) lab, the isentropic efficiency can now reach about 65%. The results show that the WRR is a feasible and promising technology in pressured gas refrigeration cases.

  2. Performance modeling of optical refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Mills, G.; Mord, A. [Ball Aerospace and Technologies Corp., Boulder, CO (United States). Cryogenic and Thermal Engineering

    2006-02-15

    Optical refrigeration using anti-Stokes fluorescence in solids has several advantages over more conventional techniques including low mass, low volume, low cost and no vibration. It also has the potential of allowing miniature cryocoolers on the scale of a few cubic centimeters. It has been the topic of analysis and experimental work by several organizations. In 2003, we demonstrated the first optical refrigerator. We have developed a comprehensive system-level performance model of optical refrigerators. Our current version models the refrigeration cycle based on the fluorescent material emission and absorption data at ambient and reduced temperature for the Ytterbium-ZBLAN glass (Yb:ZBLAN) cooling material. It also includes the heat transfer into the refrigerator cooling assembly due to radiation and conduction. In this paper, we report on modeling results which reveal the interplay between size, power input, and cooling load. This interplay results in practical size limitations using Yb:ZBLAN. (author)

  3. Anomalous Brownian refrigerator

    Science.gov (United States)

    Rana, Shubhashis; Pal, P. S.; Saha, Arnab; Jayannavar, A. M.

    2016-02-01

    We present a detailed study of a Brownian particle driven by Carnot-type refrigerating protocol operating between two thermal baths. Both the underdamped as well as the overdamped limits are investigated. The particle is in a harmonic potential with time-periodic strength that drives the system cyclically between the baths. Each cycle consists of two isothermal steps at different temperatures and two adiabatic steps connecting them. Besides working as a stochastic refrigerator, it is shown analytically that in the quasistatic regime the system can also act as stochastic heater, depending on the bath temperatures. Interestingly, in non-quasistatic regime, our system can even work as a stochastic heat engine for certain range of cycle time and bath temperatures. We show that the operation of this engine is not reliable. The fluctuations of stochastic efficiency/coefficient of performance (COP) dominate their mean values. Their distributions show power law tails, however the exponents are not universal. Our study reveals that microscopic machines are not the microscopic equivalent of the macroscopic machines that we come across in our daily life. We find that there is no one to one correspondence between the performance of our system under engine protocol and its reverse.

  4. THERMODYNAMIC ANALYSIS OF REFRIGERANT MIXTURES IN VAPOR COMPRESSION REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Erol ARCAKLIOĞLU

    2003-02-01

    Full Text Available In this study, performance analysis of vapor-compression refrigeration system with suction/liquid line heat exchanger has been realized with the calculations of the coefficient of performance, and volumetric refrigeration capacity values using different refrigerant mixtures. Refrigerants R12, R22, and R502 of CFCs, R134a, R152a, R125, R143a, and R32 of HFCs, R600a, and R290 of HCs, and their binary, ternary, and mixtures of different mass ratios have been used as working fluids. In order to decrease global pollution due to CFCs in accordance with Montreal Protocol in 1987, it is considered to use the refrigerant mixtures of HFCs, and HCs instead of CFCs (R12, R22, and R502. For this reason, the performance comparison of the new mixtures with CFC refrigerants has been done in the frame of this study. To compare the performance values, constant temperature method has been used. Thermodynamic properties of refrigerants that were used in the performance calculations have been taken from REFPROP 6.01. For this aim, new software has written in FORTRAN programing language using sub-programs of REFPROP, and all related calculations of performance have been achieved by this software.

  5. High-power stirling-type pulse tube cooler for power engineering applications of high temperature superconductivity; Hochleistungspulsrohrkuehler vom Stirling-Typ fuer energietechnische Anwendungen der Hochtemperatursupraleitung

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Marc

    2015-12-15

    For the cooling of high temperature superconducting 4 MVA machines (motors or generators), a single-stage Stirling-type pulse-tube cryocooler was built. The cooling power, which the cryocooler was aimed for, is 80 - 100 W at 30 K with an electrical input power of 10 kW (8 kW pV-power). The advantages of this cooler type compared to traditional cooling concepts are an increased reliability and long maintenance intervals. While single-stage Stirling-type pulse-tube cryocoolers for the temperature range of liquid nitrogen (77 K) are already commercially available, there exist currently no commercial systems for the temperature range near 30 K, which is the important range for applications of high-temperature superconductivity. The experimental setup consisted of a 10 kW linear compressor, type 2S297W, from CFIC Inc. which was used as the pressure wave generator. The compressor was operated by a Micromaster 440 frequency inverter from Siemens, which was controlled by a custom-made computer program. The cold head was made in inline configuration, in order to avoid deflection losses. During the first cool-downs tests a temperature inhomogeneity occurred in the regenerator at low temperature and high pV-power, which was attributed to a constant mass flow (circular dc-flow) within the regenerator. This firstly observed dc-flow, generates a net energy flow from the hot end to the cold end of the regenerator, which reduces the cooling capacity considerably and hence the minimum attainable temperature is severely increased. For the design and optimization of the cold-head, a cryocooler model was initially created using the commercial simulation software Sage, which did not include the regenerator inhomogeneity seen in the experiment. For the modeling of the observed streaming inhomogeneity caused by the dc-flow, the regenerator was replaced by two identical parallel regenerators with variable transverse thermal coupling. In the inhomogeneous case (without dc-flow) the

  6. Effects of Improved Pulsed Washpipe Method in Preventing Nasogastric Tube Occlusion%改良脉冲式冲管法预防鼻胃管堵管的效果

    Institute of Scientific and Technical Information of China (English)

    金月红; 张锦丽

    2011-01-01

    Objective To explore the effect of pulse washpipe in preventing nasogastric tube occlusion in critical patients.Methods From March 2007 to August 2010,102 critical patients with nasogastric tube enteral nutrition were divided in to experiment group(n= 58)and control group(n=44).The patients in the control group and the experiment group adopted the traditional washpipe method and improved pulse injection method respectively.The incidences of nasogastric tube occlusion and complications were compared between the two groups.Results The incidence of nasogastric tube occlusion(3.4%) in experiment group was significantly lower than that (15.9 %) of control group (P < 0.05).The two group of patients were presented with different degrees of complications of diarrhea, stomach retention, food reverse flow and gastrointestinal bleeding, without statistically significant difference (P > 0.05).Conclusion The improved pulsed washpipe method can effectively prevent stomach tube obstruction and do not increase the incidence of complications.%目的 探讨脉冲式冲管在预防鼻胃管堵塞中的效果.方法 将2007年3月至2010年8月入住ICU且使用鼻胃管的102例危重症患者分为试验组58例和对照组44例,管饲后分别采用改良脉冲式法及传统方法 冲洗管道,比较两组患者的堵管发生率及并发症发生情况.结果 试验组堵管发生率(3.4%)低于对照组(15.9%),差异有统计学意义(P<0.05);两组患者均出现不同程度的腹泻、胃潴留、食物反流、消化道出血等并发症,差异无统计学意义(P>0.05).结论 采用改良的脉冲式推注法冲管能有效预防鼻胃管堵塞,且不增加并发症的发生率.

  7. Enhanced shell-and-tube heat eschangers for the power and process industries. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bergles, A.E.; Jensen, M.K.; Somerscales, E.F.; Curcio, L.A. Jr.; Trewin, R.R.

    1994-08-01

    Single-tube pool boiling tests were performed with saturated pure refrigerants and binary mixtures of refrigerants. Generally, with pure refrigerants, the High Flux surface performed better at the higher heat fluxes compared to the Turbo-B tube, and both enhanced surfaces performed significantly better than smooth surface. In tests of R-11/R-113 mixtures, the enhanced surfaces had much less degradation in heat transfer coefficient due to mixture effects compared to smooth tubes; the largest degradation occurred at a mixture of 25% R-11/75% R-113. Under boiling in saturated aqueous solution of calcium sulfate, with a single tube, effects of fouling were more pronounced at the higher heat fluxes for all surfaces. Two staggered tube bundles were tested with tube pitch-diameter ratios of 1.17 and 1.50. For the pure refrigerant, tests on the smooth-tube bundle indicated that the effects on the heat transfer coefficient of varying mass flux, quality, and tube-bundle geometry were small, except at low heat fluxes. Neither enhanced surface showed any effect with changing mass flux or quality. The binary mixture bundle-boiling tests had results that were very similar to those obtained with the pure refrigerants. When boiling a refrigerant-oil mixture, all three surfaces (smooth, High Flux, and Turbo-B) experienced a degradation in its heat transfer coefficient; no surface studied was found to be immune or vulnerable to the presence of oil than another surface.

  8. 46 CFR 154.1720 - Indirect refrigeration.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression....

  9. 2D numerical modelling of gas temperature in a nanosecond pulsed longitudinal He-SrBr2 discharge excited in a high temperature gas-discharge tube for the high-power strontium laser

    Science.gov (United States)

    Chernogorova, T. P.; Temelkov, K. A.; Koleva, N. K.; Vuchkov, N. K.

    2016-05-01

    An active volume scaling in bore and length of a Sr atom laser excited in a nanosecond pulse longitudinal He-SrBr2 discharge is carried out. Considering axial symmetry and uniform power input, a 2D model (r, z) is developed by numerical methods for determination of gas temperature in a new large-volume high-temperature discharge tube with additional incompact ZrO2 insulation in the discharge free zone, in order to find out the optimal thermal mode for achievement of maximal output laser parameters. A 2D model (r, z) of gas temperature is developed by numerical methods for axial symmetry and uniform power input. The model determines gas temperature of nanosecond pulsed longitudinal discharge in helium with small additives of strontium and bromine.

  10. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J.; Nelson, Scott D.; Poole, Brian R.

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  11. Magnetic Refrigeration and the Magnetocaloric Effect

    DEFF Research Database (Denmark)

    Petersen, Thomas Frank; Pryds, Nini; Smith, Anders

    2006-01-01

    Magnetic refrigeration at room temperature is an emerging technology for refrigeration, which promises low energy consumption and is environmentalle friendly. Magnetic refrigeration is based on the magnetocaloric effect, which manifests itself as a reversibel increase in temperature when magnetic...... material are plased in a magnetic field. This paper introduces and describes magnetic refrigeration cycles and the magnetocaloric effect, and shows how magnetic refrigeration can be an alternative to vapour-compression refrigeration,. A review of the Danish research on magnetic refrigeration at Risø...

  12. Refrigerating fluids; Fluides frigorigenes

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1999-03-01

    Refrigerating fluids are experiencing a real revolution since few years. CFCs with their destructive effect on the ozone layer are now prohibited while HCFCs will be progressively eliminated and replaced by HFCs. However, HFCs can contribute to the increase of the greenhouse effect. The solutions proposed by thermal engineering professionals consist in the confinement of air-conditioning installations (elimination of recurrent leaks) and in the improvement of installations efficiency. HCFC fluids like the R 22 are still widely used in air-conditioning but they are supposed to be replaced by HFC fluids like the R 134a, the R 407C or the R 410A. This short paper gives a brief presentation of these fluids and of their chemical characteristics. (J.S.)

  13. Supermarket refrigerators with natural refrigerants; Supermarktkaelteanlagen mit natuerlichen Kaeltemitteln. Erfahrungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Haaf, S.; Heinbokel, B. [Linde AG, Koeln (Germany). Gechaeftsbereich Linde Kaeltetechnik

    2002-09-01

    In view of the high contribution to global warming of H-CFC refrigerants, substitution has been a key concern for several years now. Leakage protection measures were enhanced, and Linde also installed many supermarket refrigerators with natural refrigerants, i.e. ammonia, propene and carbon dioxide. The environmental and economic aspects are assessed on the basis of the experience gained, and the systems are compared with H-CFC refrigeration systems. [German] Wegen des betraechtlichen Treibhauspotentials von HFKW-Kaeltemitteln werden seit Jahren Anstrengungen unternommen, um den von diesen Stoffen ausgehenden Treibhauseffekt zu reduzieren. Neben Massnahmen zur Verminderung von Leckagen sowie zur Verringerung von Kaeltemittel-Fuellmengen wurden im Laufe der letzten 10 Jahre von Linde auch zahlreiche Kaelteanlagen mit den natuerlichen Kaeltemitteln Ammoniak, Propen und Kohlendioxid in Supermaerkten installiert. Auf Basis der gesammelten Erfahrungen wird eine Einschaetzung der umweltspezifischen und wirtschaftlichen Aspekte im Vergleich zu Anlagen mit HFKW-Kaeltemitteln vorgenommen. (orig.)

  14. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A.; Jurkowski, R. [CIAT, 01 - Culoz (France)

    1997-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  15. High Efficiency Refrigeration Process Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A refrigeration cycle is proposed for development which can reduce compressor work and increase cooling effect, by eliminating a portion of the irreversabilities...

  16. Analysis of hot end temperature impact on inline pulse tube cryocooler%热端温度对直线型脉冲管制冷机的影响分析

    Institute of Scientific and Technical Information of China (English)

    张安阔; 陈曦; 吴亦农; 张华; 杨开响

    2013-01-01

    基于一台单级直线型脉冲管制冷机,研究分析了热端温度变化对制冷机性能的影响关系.建立了一维数值模型,分析了高频脉冲管制冷机内部相关热力学参数随热端温度变化的关系,从而揭示了热端温度变化影响整机性能的作用机理.最后通过实验数据和模拟值的比较研究,验证了模型的准确性.%Hot end temperature impact of a single-stage inline pulse tube cryocooler was studied.Onedimensional numerical model was set up to analyze the thermodynamic parameters of the pulse tube cryocooler,which can explain the reason for deterioration of cryocooler performance when increasing the hot end temperature.Experimental results show a good agreement between experimental data and theoretical simulation values.

  17. Rare Earths and Magnetic Refrigeration

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Magnetic refrigeration is a revolutionary, efficient, environmentally friendly cooling technology, which is on the threshold of commercialization. The magnetic rare earth materials are utilized as the magnetic refrigerants in most cooling devices, and for many cooling application the Nd2Fe14B permanent magnets are employed as the source of the magnetic field. The status of the near room temperature magnetic cooling was reviewed.

  18. Short-Cycle Adsorption Refrigerator

    Science.gov (United States)

    Chan, C. K.

    1988-01-01

    Modular adsorption/Joule-Thomson-effect refrigerator offers fast regeneration; adsorption/desorption cycle time expected to be 1 minute. Pressurized hydrogen generated by bank of compressor modules during heating phase passes through system of check valves and expands in Joule-Thomson junction as it enters refrigeration chamber. Hydrogen absorbs heat from load before it is sucked out by another bank of compressor modules in cooling phase.

  19. Development and experimental investigation of a miniature-scale refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yuting, E-mail: wuyuting@bjut.edu.c [Key Laboratory of Enhanced Heat Transfer and Energy Conservation, Ministry of Education and Key Laboratory of Heat Transfer and Energy Conversion, Beijing Municipality, College of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022 (China); Ma Chongfang; Zhong Xiaohui [Key Laboratory of Enhanced Heat Transfer and Energy Conservation, Ministry of Education and Key Laboratory of Heat Transfer and Energy Conversion, Beijing Municipality, College of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022 (China)

    2010-01-15

    Two generation miniature Wankel compressors with the cooling capacity of 300 W were developed. The weight of first generation compressor is 700 g and that of second generation is 400 g. A miniature spiral-tube type evaporator is developed which weighs 0.26 kg and a brazed aluminum multi-channel parallel type condenser is also developed which weighs 0.3 kg. Based on the development of above components, a miniature refrigeration system prototype with a cooling capacity of 300 W was integrated and the system weighs about 2.85 kg. An experimental system for miniature refrigeration system was set up. The tests of the performance of miniature refrigeration system were done. The experimental results indicated that the compression ratio of the compressor is above 3.0, the refrigerating output of the system is above 300 W and the coefficient of performance of the developed micro climate cooling system was about 2.3.

  20. Analysis of Eco friendly Refrigerants Usage in Air-Conditioner

    Directory of Open Access Journals (Sweden)

    C. Chinnaraj

    2011-01-01

    Full Text Available Problem statement: There are two types of global warming contributions through refrigeration and air conditioning systems. The first one is the Direct Global Warming Potential (DGWP due to the emission of refrigerants and their interaction with heat radiation. The second one is the Indirect Global Warming Potential (IDGWP due to the emission of Carbon Dioxide (CO2 by consuming the energy that is generated through the combustion of fossil fuels. Most of refrigerants used in vapor Compression system were Chlorofluorocarbon (CFCs and Hydro Chlorofluorocarbon (HCFCs which contains chlorine and if any leakage in the system, these gases will go up and reach stratosphere. The chlorine atoms in the gases will act as a catalyst to destroy ozone layer and cause ozone depletion which causes health hazards, global warming, melting of polar ice caps and drought. Hence, it is necessary to minimize the Global warming and Ozone depletion. The refrigerant R22 widely used in the air-conditioners is a major Contributor of Chlorofluorocarbons (CFCs which cause irreparable loss to the ozone layer and has to be replaced. Approach: To conserve the energy and minimize the global warming, the systems should be designed as more energy efficient and also to minimize Ozone depletion, the eco friendly refrigerants are to be selected and tested as alternative refrigerants to R22. Hence, a window air conditioner of 3.5 kW capacity fitted with Electronic Expansion Valve (EEV instead of capillary tube as an expansion device, was tested for its performance with the selected eco friendly refrigerants R407C and R290 as an alternative to R22 under fixed indoor and outdoor chamber temperatures in the experimental set up and varying the EEV opening. Results: It has been observed from the experimental studies that when the smaller capacity R22 window air conditioner with EEV is retrofitted with R407C and R290, compared to the performance given by R22, the Coefficient Of Performance

  1. Refrigerant recycling apparatus, method and system

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, J.P.; Gordon, R.F.

    1993-07-13

    A refrigerant recycling apparatus for recovery and purification of refrigerant is described comprising: (a) an input conduit system for connecting a refrigerant source to the refrigerant recycling apparatus; (b) a first disposable filter capable of removing moisture and particulates from the refrigerant, said disposable filter being located such that the filter is easily accessible for service; (c) a primary heat exchanger configured so as to provide heat to the refrigerant thereby causing the refrigerant to be vaporized; (d) a secondary heat exchanger for further heating of the refrigerant to further assist in vaporization of the refrigerant; (e) an expansion valve located prior in line to said primary and secondary heat exchangers for controlling the flow of the refrigerant and reducing the pressure of the refrigerant, thereby allowing the refrigerant to expand to a predominantly gaseous state; (f) a separator for removing oil from the refrigerant; (g) a compressor pump having a vacuum producing inlet and a pressure producing outlet, the pump being a hermetically sealed, lubricated-for-life positive displacement pump; (h) a condenser for cooling the refrigerant; (i) a second disposable filter for removing moisture, acids, and other particulates from the refrigerant passing there through, said disposable filter being located in an area easily accessible for servicing; (j) an interconnecting conduit system for interconnecting the input conduit system, the first and second disposable filters, the heat exchangers, the compressor pump, the condenser, the expansion valve, and the refrigerant source; (k) a moisture indicator located after the second disposable filter, for measuring the degree of moisture present within the refrigerant after the refrigerant has flowed through the second disposable filter.

  2. 压缩机背腔作为脉冲管制冷机气库的研究%Characterization of a Pulse Tube Cooler With the Compressor Backside as the Reservoir

    Institute of Scientific and Technical Information of China (English)

    王晓涛; 罗二仓; 戴巍; 周远

    2011-01-01

    As one important cryocooler,the pulse tube cooler usually use inertance-tube plus reservoir as the phase shifter.However,this relatively large volume reservoir makes the cooler not to be as compact as the Stirling cryocoolers.The backside of linear compressor also has a large volume. To improve the compactness,the inertance-tube is connected to the backside of compressor.The theoretical model is present to compare the system performance with the reservoir.The simulation results show that this cooler is able to work properly and can achieve a similar cooling performance after optimizing the size of inertance-tube.%脉冲管制冷机是一种重要的小型低温制冷机,通常高频脉冲管制冷机采用惯性管加气库的调相方式,然而较大的气库降低了系统的紧凑性。对于直线压缩机,其背腔也具有较大的体积,为提高系统的紧凑性,本文进行了使用压缩机背腔作为气库用于调相脉冲管制冷机的研究工作。研究结果表明采用这种方案的制冷机是可行的,当背腔体积足够大时,通过调整惯性管尺寸,其性能接近使用独立气库的脉冲管制冷机的性能。

  3. Performance of Gas Purge System of Absorption Refrigerating Machine

    Science.gov (United States)

    Kunugi, Yoshifumi; Ouchi, Tomihisa; Usui, Sanpei; Sugimoto, Shigeo

    Experimental studies on performance of two gas purge systems for the lithium bromide-water absorption refrigerating machine are presented in this paper. The first purge system is that the solution flow entrains the incondensable gas from the absorber in the first purge chamber, then the incondesable gas from the condenser in the second purge chamber. The second purge system is that the solution flow entrains the incondensable gas, separates it in the separator, and then returns to the refrigerating machine through the inverted U tube. As a result, purged gas rate of both gas purge systems conforms to the theoretical equation ; S=V0(P-P0), where S is purged gas rate, V0 is exhaust gas rate, P is pressure of purge chamber, and P0 is saturated vapor pressure of solution.

  4. Theorical analysis and experiments investigation on gravity effect in large capacity high frequency pulse tube cryocooler%大冷量高频脉冲管制冷机重力影响的理论分析及实验研究

    Institute of Scientific and Technical Information of China (English)

    侯小锋; 杨鲁伟; 梁惊涛

    2012-01-01

    通过对重力场中脉冲管管内部的流体力学方程进行化简和无量纲化,提出了影响脉冲管制冷机重力特性的无量纲数(ρgl/Pa),并对大冷量高频脉冲管的重力特性进行试验研究.试验结果表明:提高输入功率、减小惯性管的尺寸、减小充气压力、减小脉冲管的尺寸以及提高脉冲管制冷机的运行温区能够改变无量纲数(ρgl/Pa)的各个参数从而减小无量纲数(ρgl/Pa)的大小,进而减弱重力方向性的影响.%A dimensionless number of (pgl/pa) was obtained by simplifying and dimensionlessing the fluid equations inside the pulse tube in gravity field. An experimental investigation also was carried out on gravity effect in large capacity high frequency pulse tube cryocooler( PTC). The results show that increasing the input power and temperature of pulse tube, decreasing charge pressure, and decreasing the dimensions of inertant tube and pulse tube,all can decrease the dimensionless number of (pgl/pa) ,and also wakens the gravity effect in PTC.

  5. 温度回路-小孔脉管制冷中的新现象%TEMPERATURE LOOP, A NEW PHENOMENON IN A GM-TYPE ORIFICE PULSE TUBE REFRIGERATOR

    Institute of Scientific and Technical Information of China (English)

    甘智华

    2005-01-01

    一台可工作在双向进气模式和小孔模式下的单级脉管制冷机,当双向进气方式采用并联双阀双向进气时,最低制冷温度为19.3 K,50 K以下的制冷量变化约为2 W/K;当双向进气阀门关闭时,制冷机就工作在小孔模式下,最近的研究工作发现,当制冷机工作在小孔模式下时出现了一个新的现象-脉管冷端温度存在温度回路,该特点与脉管冷端的热负荷及小孔开度的调节方法有关,该现象的发现对于理解双向进气模式下温度不稳定问题提供了一个新的思路.

  6. Performance of the SCUBA-2 dry dilution refrigerator: 4 years of operation at the JCMT

    Science.gov (United States)

    Bintley, Dan; Kuroda, John T.; Starman, Erik G.; Craig, Simon; Holland, Wayne S.

    2012-09-01

    Cryogen free or ‘dry’ dilution refrigerators that integrate a cryocooler such as a two stage pulse tube to replace the conventional liquid helium bath and 1K pot, have become a practical alternative for cooling astronomical detectors to mK temperatures and offer many advantages. SCUBA-2, the new submillimetre camera in operation at the JCMT, on the summit of Mauna Kea, Hawaii, was one of the first instruments to use such a fridge design. The dry dilution fridge for SCUBA-2 has now been in service for almost 4 years during commissioning at JCMT. In the most recent astronomical commissioning phase, the dilution fridge was in continuous operation for 10 months with no loss of base temperature or cooling power, cooling the SCUBA-2 detector arrays to below 100mK while maintaining a further 100Kg of enclosure, shields and SQUID amplifiers at 1K. In this paper we review some of the lessons from operating a dry dilution fridge at the JCMT and the necessary changes that have been incorporated. We present the performance of the fridge and discus its role in ensuring the success of SCUBA-2.

  7. REDUCING REFRIGERANT EMISSIONS FROM SUPERMARKET SYSTEMS

    Science.gov (United States)

    Large refrigeration systems are found in several applications including supermarkets, cold storage warehouses, and industrial processes. The sizes of these systems are a contributing factor to their problems of high refrigerant leak rates because of the thousands of connections, ...

  8. REDUCING REFRIGERANT EMISSIONS FROM SUPERMARKET SYSTEMS

    Science.gov (United States)

    Large refrigeration systems are found in several applications including supermarkets, cold storage warehouses, and industrial processes. The sizes of these systems are a contributing factor to their problems of high refrigerant leak rates because of the thousands of connections, ...

  9. Refrigeration system having dual suction port compressor

    Science.gov (United States)

    Wu, Guolian

    2016-01-05

    A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

  10. Determination of space-time resolved electron temperature in nanosecond pulsed longitudinal discharge in various noble gases and discharge tube constructions

    Science.gov (United States)

    Temelkov, K. A.; Slaveeva, S. I.; Chernogorova, T. P.

    2016-03-01

    Using our results obtained by the analytical solution of the steady-state heat conduction equation for electrons and deriving a new thermal conductivity, 2D (r, t) numerical solution of nonstationary heat conduction, an equation for electrons is found for nanosecond pulsed longitudinal discharge in helium for two different pressures and in neon.

  11. Load forecasting for supermarket refrigeration

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Aalborg Nielsen, Henrik

    This report presents a study of models for forecasting the load for supermarket refrigeration. The data used for building the forecasting models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. The load for refrigeration is the sum of all cabinets in the supermarket, both low and medium temperature cabinets, and spans a period of one year. As input to the forecasting models the ambient temperature observed near the supermarket together with weather forecasts are used. Every hour...... the hourly load for refrigeration for the following 42 hours is forecasted. The forecast models are adaptive linear time-series models which are fitted with a computationally efficient recursive least squares scheme. The dynamic relations between the inputs and the load is modeled by simple transfer...

  12. Energy efficient Supermarket Refrigeration with Ejectors

    OpenAIRE

    Calvo Hoyas, Raul

    2014-01-01

    Nowadays, the use of R744 or carbon dioxide has been increased as a working fluid in many refrigerant systems. Nevertheless, one disadvantage for use this refrigerant is the thermodynamic losses produced in the refrigerant system when the fluid is throttled. These losses are increased if the refrigerant system is working in transcritical operation conditions. But, there is an option and it consists of using an ejector instead of the conventional expansion valve in order to reduce the energy l...

  13. Tracheostomy tubes.

    Science.gov (United States)

    Hess, Dean R; Altobelli, Neila P

    2014-06-01

    Tracheostomy tubes are used to administer positive-pressure ventilation, to provide a patent airway, and to provide access to the lower respiratory tract for airway clearance. They are available in a variety of sizes and styles from several manufacturers. The dimensions of tracheostomy tubes are given by their inner diameter, outer diameter, length, and curvature. Differences in dimensions between tubes with the same inner diameter from different manufacturers are not commonly appreciated but may have important clinical implications. Tracheostomy tubes can be cuffed or uncuffed and may be fenestrated. Some tracheostomy tubes are designed with an inner cannula. It is important for clinicians caring for patients with a tracheostomy tube to appreciate the nuances of various tracheostomy tube designs and to select a tube that appropriately fits the patient. The optimal frequency of changing a chronic tracheostomy tube is controversial. Specialized teams may be useful in managing patients with a tracheostomy. Speech can be facilitated with a speaking valve in patients with a tracheostomy tube who are breathing spontaneously. In mechanically ventilated patients with a tracheostomy, a talking tracheostomy tube, a deflated cuff technique with a speaking valve, or a deflated cuff technique without a speaking valve can be used to facilitate speech. Copyright © 2014 by Daedalus Enterprises.

  14. Load forecasting of supermarket refrigeration

    DEFF Research Database (Denmark)

    Rasmussen, Lisa Buth; Bacher, Peder; Madsen, Henrik

    2016-01-01

    This paper presents a novel study of models for forecasting the electrical load for supermarket refrigeration. The data used for building the models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. Every hour the hourly electrical load for refrigeration is forecasted for the following 42 h. The forecast models are adaptive linear time series models. The model has two regimes; one for opening hours and one for closing hours, this is modeled by a regime switching model and two different...

  15. Novel materials for laser refrigeration

    Science.gov (United States)

    Hehlen, Markus P.

    2009-02-01

    The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which hωmax 100 ppb are believed to be the main reason for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF3-LiF are considered as alternatives to ZBLAN, and the crystalline system KPb2Cl5 :Dy3+ is identified as a prime candidate for high-efficiency laser cooling.

  16. Solar Refrigerators Store Life-Saving Vaccines

    Science.gov (United States)

    2014-01-01

    Former Johnson Space Center engineer David Bergeron used his experience on the Advanced Refrigeration Technology Team to found SunDanzer Refrigeration Inc., a company specializing in solar-powered refrigerators. The company has created a battery-free unit that provides safe storage for vaccines in rural and remote areas around the world.

  17. Heat driven refrigeration cycle at low temperatures

    Institute of Scientific and Technical Information of China (English)

    HE Yijian; HONG Ronghua; CHEN Guangming

    2005-01-01

    Absorption refrigeration cycle can be driven by low-grade thermal energy, such as solar energy, geothermal energy and waste heat. It is beneficial to save energy and protect environment. However, the applications of traditional absorption refrigeration cycle are greatly restricted because they cannot achieve low refrigeration temperature. A new absorption refrigeration cycle is investigated in this paper, which is driven by low-grade energy and can get deep low refrigeration temperature. The mixture refrigerant R23+R134a and an absorbent DMF are used as its working fluid. The theoretical results indicate that the new cycle can achieve -62℃ refrigeration temperature when the generation temperature is only 160℃. This refrigeration temperature is much lower than that obtained by traditional absorption refrigeration cycle. Refrigeration temperature of -47.3℃ has been successfully achieved by experiment for this new cycle at the generation temperature of 157℃, which is the lowest temperature obtained by absorption refrigeration system reported in the literature up to now. The theoretical and experimental results prove that new cycle can achieve rather low refrigeration temperature.

  18. Simulation of a single stage orifice G-M type pulse tube cryocooler based on Sage%单级 G-M 型小孔脉管制冷机 Sage 建模

    Institute of Scientific and Technical Information of China (English)

    刘东立; 甘智华

    2015-01-01

    G-M型脉管制冷机作为一项成熟的低温制冷技术,尚缺少公开的整机模拟分析方法。Sage软件包含压缩机、高低压切换阀和脉管制冷机冷头相关部件等模型。使用Sage软件建立了单级G-M型小孔脉管制冷机整机模型。将现有单级G-M型小孔脉管制冷机的实验设计参数作为输入参数,将Sage模型的计算结果与该制冷机实验结果进行对比,初步验证了模型的准确性,并重点计算分析高低压切换阀的孔径、时序对制冷机性能的影响。%The simulation of a whole G-M type pulse tube ( GMPT) cryocooler system is not reported before, although this kind of cryocooler is a mature technology .The Sage software has the models of com-pressors , switching valves and the parts to make up the cold head of the pulse tube cryocoolers .The whole system of a single stage orifice GMPT cryocooler was simulated based on Sage .The design paremeters of an existed cryocooler are substituted into the Sage model and then the calculation results are compared to the existed experimental results .The preliminary validation can be achieved by the comparation .The effects of diameters and the time ratio of the switching valves were analized based on the calculation results .

  19. CFD modeling and experimental verification of a single-stage coaxial Stirling-type pulse tube cryocooler without either double-inlet or multi-bypass operating at 30-35 K using mixed stainless steel mesh regenerator matrices

    Science.gov (United States)

    Dang, Haizheng; Zhao, Yibo

    2016-09-01

    This paper presents the CFD modeling and experimental verifications of a single-stage inertance tube coaxial Stirling-type pulse tube cryocooler operating at 30-35 K using mixed stainless steel mesh regenerator matrices without either double-inlet or multi-bypass. A two-dimensional axis-symmetric CFD model with the thermal non-equilibrium mode is developed to simulate the internal process, and the underlying mechanism of significantly reducing the regenerator losses with mixed matrices is discussed in detail based on the given six cases. The modeling also indicates that the combination of the given different mesh segments can be optimized to achieve the highest cooling efficiency or the largest exergy ratio, and then the verification experiments are conducted in which the satisfactory agreements between simulated and tested results are observed. The experiments achieve a no-load temperature of 27.2 K and the cooling power of 0.78 W at 35 K, or 0.29 W at 30 K, with an input electric power of 220 W and a reject temperature of 300 K.

  20. A single-pulse shock tube coupled with high-repetition-rate time-of-flight mass spectrometry and gas chromatography for high-temperature gas-phase kinetics studies

    Science.gov (United States)

    Sela, P.; Shu, B.; Aghsaee, M.; Herzler, J.; Welz, O.; Fikri, M.; Schulz, C.

    2016-10-01

    Shock tubes are frequently used to investigate the kinetics of chemical reactions in the gas phase at high temperatures. Conventionally, two complementary arrangements are used where either time-resolved intermediate species measurements are conducted after the initiation of the reaction or where the product composition is determined after rapid initiation and quenching of the reaction through gas-dynamic processes. This paper presents a facility that combines both approaches to determine comprehensive information. A single-pulse shock tube is combined with high-sensitivity gas chromatography/mass spectrometry for product composition and concentration measurement as well as high-repetition-rate time-of-flight mass spectrometry for time-dependent intermediate concentration determination with 10 μs time resolution. Both methods can be applied simultaneously. The arrangement is validated with investigations of the well-documented thermal unimolecular decomposition of cyclohexene towards ethylene and 1,3-butadiene at temperatures between 1000 and 1500 K and pressures ranging from 0.8 to 2.4 bars. The comparison shows that the experimental results for both detections are in very good agreement with each other and with literature data.

  1. High Efficiency, Low Emission Refrigeration System

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

    2016-08-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for

  2. Low-temperature magnetic refrigerator

    Science.gov (United States)

    Barclay, John A.

    1985-01-01

    The disclosure is directed to a low temperature 4 to 20 K. refrigeration apparatus and method utilizing a ring of magnetic material moving through a magnetic field. Heat exchange is accomplished in and out of the magnetic field to appropriately utilize the device to execute Carnot and Stirling cycles.

  3. 带包覆层铁磁性管道腐蚀脉冲涡流检测技术%Pulsed Eddy Current Inspection Technique in for Corrosion under Insulation in Ferromagnetic Tubes

    Institute of Scientific and Technical Information of China (English)

    康小伟; 付跃文

    2011-01-01

    In this paper, we applied pulsed eddy current(PEC} inspection technique to detect ferromagnetic tubes corrosion under insulation. By detecting corrosion of different thickness insulation and different defect areas and deepness, variation of detection sensitivity was analyzed. It was proved that as for corrosion defect with a large area, pulsed eddy current had a very good ability in testing under appropriate inspection parameters, even with a thick insulation.%应用脉冲涡流检测技术,对带包覆层的铁磁性管道腐蚀进行了检测。对不同厚度的包覆层、不同面积和深度的腐蚀缺陷进行了试验,分析检测灵敏度的变化。试验结果表明,对于较大面积的腐蚀缺陷,即使包覆层较厚,在合适的检测参数下,脉冲涡流也具有很好的检测能力。

  4. Application of magnetic refrigeration and its assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kitanovski, Andrej [University of Applied Sciences of Western Switzerland, Hesso, Institute of Thermal Sciences IGT-SIT, Route de Cheseaux 1, CH 1401 Yverdon-les-Bains (Switzerland)], E-mail: andrej.kitanovski@heig-vd.ch; Egolf, Peter W. [University of Applied Sciences of Western Switzerland, Hesso, Institute of Thermal Sciences IGT-SIT, Route de Cheseaux 1, CH 1401 Yverdon-les-Bains (Switzerland)

    2009-04-15

    Magnetic refrigeration has the potential to replace conventional refrigeration-with often problematic refrigerants-in several niche markets or even some main markets of the refrigeration domain. Based on this insight, for the Swiss Federal Office of Energy a list of almost all existing refrigeration technologies was worked out. Then an evaluation how good magnetic refrigeration applies to each of these technologies was performed. For this purpose a calculation tool to determine the coefficient of performance (COP) and the exergy efficiency as a function of the magnetic field strength and the rotation frequency of a rotary-type magnetic refrigerator was developed. The evaluation clearly shows that some application domains are more ideal for a replacement of conventional refrigerators by their magnetic counterparts than others. In the pre-study, four good examples were chosen for a more comprehensive investigation and working out of more detailed results. In this article, the calculation method is briefly described. COP values and exergy efficiencies of one very suitable technology, namely the magnetic household refrigerator, are presented for different operation conditions. Summarizing, it is stated that magnetic refrigeration is a serious environmentally benign alternative to some conventional cooling, refrigeration and air-conditioning technologies.

  5. Integrated Refrigeration and Storage for Advanced Liquid Hydrogen Operations

    Science.gov (United States)

    Swanger, A. M.; Notardonato, W. U.; Johnson, W. L.; Tomsik, T. M.

    2016-01-01

    NASA has used liquefied hydrogen (LH2) on a large scale since the beginning of the space program as fuel for the Centaur and Apollo upper stages, and more recently to feed the three space shuttle main engines. The LH2 systems currently in place at the Kennedy Space Center (KSC) launch pads are aging and inefficient compared to the state-of-the-art. Therefore, the need exists to explore advanced technologies and operations that can drive commodity costs down, and provide increased capabilities. The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) was developed at KSC to pursue these goals by demonstrating active thermal control of the propellant state by direct removal of heat using a cryocooler. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The key technology challenge was efficiently integrating the cryogenic refrigerator into the LH2 storage tank. A Linde LR1620 Brayton cycle refrigerator is used to produce up to 900W cooling at 20K, circulating approximately 22 g/s gaseous helium through the hydrogen via approximately 300 m of heat exchanger tubing. The GODU-LH2 system is fully operational, and is currently under test. This paper will discuss the design features of the refrigerator and storage system, as well as the current test results.

  6. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  7. Effects of Adding Nanoparticles on Boiling and Condensing Heat Transfer inside a horizontal round tube

    Science.gov (United States)

    Sheikholeslami, Mohsen; Sadoughi, Mohammadkazem; Shariatmadar, Hamed; Akhavan-Behabadi, Mohammad Ali

    2015-11-01

    An experimental investigation is performed on heat transfer evaluation of a nano-refrigerant flow during condensation and evaporation inside a horizontal round tube. Experiments are carried out for three working fluid types including: i) pure refrigerant (R600a); ii) refrigerant/lubricant (R600a/oil); and iii) nano-refrigerant: refrigerant/lubricant/nanoparticles (R600a/oil/CuO). Nanoparticles are added to the lubricant and their mixture is mixed with pure refrigerant. Therefore, nano-refrigerants (R600a/oil/CuO) are prepared by dispersing CuO nanoparticles with different fractions of 0.5%, 1% and 1.5% in the baseline mixture (R600a/oil). Effects of different factors including vapor quality, mass flux, and nanoparticles on the heat transfer coefficient are examined for both of condensation and evaporation flows, separately. The results shows that maximum heat transfer augmentation of 79% and 83% are achieved by using the refrigerant/lubricant/nanoparticles mixture, in comparison with the pure refrigerant case in condensation and evaporation, respectively which are occurred for nano-refrigerant with 1.5% mass fraction in both of them.

  8. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    Science.gov (United States)

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published

  9. Detection Method of the Circulating Composition in a Refrigeration Cycle with Ternary Zeotropic Refrigerant Mixture R-407C

    Science.gov (United States)

    Sumida, Yoshihiro; Okazaki, Takashi; Ueno, Yoshio

    A composition sensing circuit (CS circuit) which detects the circulating composition of the ternary zeotropic refrigerant mixture R-407C in a refrigeration cycle has been developed. The CS circuit consists of a heat exchanger, a capillary tube, two temperature detectors and one pressure detector. The circulating composition is calculated from the temperature and pressure in the circuit and the vapor-liquid equilibria for R-32/R-125/R-134a mixtures together with the approximated relation between mass fractions of R-32 and R-125. The experiments were also carried out to evaluate the accuracy of calculation. The results indicated that the difference between the calculated and measured composition was within 1% f or R-32 and R-125 and within 2% for R-134a in the circulating composition range from 17/20/63 wt% to29/30/41 wt% This difference corresponds to less than 0.5°C in the saturation temperature. This method is therefore applicable to performance stabilization and reliability improvement of the refrigeration cycle with R-407C.

  10. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

    Science.gov (United States)

    Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.

    2017-01-01

    Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar

  11. Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.

    Science.gov (United States)

    Carey, John

    This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…

  12. CO2 as a refrigerant

    CERN Document Server

    2014-01-01

    A first edition, the IIR guide “CO2 as a Refrigerant” highlights the application of carbon dioxide in supermarkets, industrial freezers, refrigerated transport, and cold stores as well as ice rinks, chillers, air conditioning systems, data centers and heat pumps. This guide is for design and development engineers needing instruction and inspiration as well as non-technical experts seeking background information on a specific topic. Written by Dr A.B. Pearson, a well-known expert in the field who has considerable experience in the use of CO2 as a refrigerant. Main topics: Thermophysical properties of CO2 – Exposure to CO2, safety precautions – CO2 Plant Design – CO2 applications – Future prospects – Standards and regulations – Bibliography.

  13. GD Copper Puts New Copper Tube Production Lines in Handan into Operation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>Recently a foundation stone laying ceremony was held in Handan for the Jinxiang Project on Precise Copper Tube for Air-conditioners and Refrigerators. The project was invested by Golden Dragon Precise Copper Tube Group Inc. of Henan Province.

  14. Performance of residential air-conditioning systems with flow maldistribution in fin-and-tube evaporators

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian;

    2011-01-01

    Refrigerant and airflow maldistribution in fin-and-tube evaporators for residential air-conditioning was investigated with numerical modeling. Fin-and-tube heat exchangers usually have a pre-defined circuitry. However, the objective in this study was to perform a generic investigation of each...

  15. The APL Satellite Refrigerator Program.

    Science.gov (United States)

    1981-07-01

    36: Fotonic sensor fibers................................ 72 Fig. 37: Vibration levels for S/N 4.......................... 73L Fig. 38: Displacers of...available. This was later achieved by using a Fotonic sensor. 70 The noise level was measured by placing an operating unit in the center of a room...with the refrigerator in operation. To measure this displacement, a Fotonic sensor was mounted on an independent surface with the sensor probe

  16. Molecular modeling of fluoropropene refrigerants.

    Science.gov (United States)

    Raabe, Gabriele

    2012-05-17

    Different fluoropropenes are currently considered as refrigerants, either as pure compounds or as components in low GWP (global warming potential) refrigerant mixtures. Due to their limited commercial production, experimental data for the thermophysical properties of fluoropropenes and their mixtures are in general rare, which hampers the exploration of their performance in technical applications. In principle, molecular simulation can be used to predict the relevant properties of refrigerants and refrigerant blends, provided that adequate intermolecular potential functions ("force fields") are available. In our earlier work (Raabe, G.; Maginn, E. J., J. Phys. Chem. B2010, 114, 10133-10142), we introduced a transferable force field for fluoropropenes comprising the compounds 3,3,3-trifluoro-1-propene (HFO-1243zf), 2,3,3,3-tetrafluoro-1-propene (HFO-1234yf), and hexafluoro-1-propene (HFO-1216). In this paper, we provide an extension of the force field model to the trans- and cis-1,3,3,3-tetrafluoro-1-propene (HFO-1234ze(E), HFO-1234ze) and the cis-1,2,3,3,3-pentafluoro-1-propene (HFO-1225ye(Z)) as well as revised simulation results for HFO-1216. We present Gibbs ensemble simulation results on the vapor pressures, saturated densities, and heats of vaporization of these compounds in comparison with experimental results. The simulation results show that the force field model enables reliable predictions of the properties of the different fluoropropenes and also reproduces well the differing vapor-liquid coexistence and vapor pressure curve of the cis- and trans-isomers of 1,3,3,3-tetrafluoro-1-propene, HFO-1234ze and HFO-1234ze(E). For these two isomers, we also present molecular dynamics simulation studies on their local structure.

  17. COMPARISON OF ENERGY AND EXERGY EFFICIENCIES OF ABSORPTION REFRIGERATION SYSTEM WITH MECHANICAL COMPRESSION REFRIGERATION SYSTEM

    OpenAIRE

    2005-01-01

    In this study, energy and exergy analysis of absorption refrigeration system using LiBr- water and mechanical compression refrigeration system using R134-a were performed at different evaporation temperatures. The results are presented in tables and figures.

  18. Energy Efficient Commercial Refrigeration with Carbon Dioxide Refrigerant and Scroll Expanders

    Energy Technology Data Exchange (ETDEWEB)

    Dieckmann, John [TIAX LLC, Lexington, MA (United States)

    2013-04-04

    Current supermarket refrigeration systems are built around conventional fluorocarbon refrigerants – HFC-134a and the HFC blends R-507 and R404A, which replaced the CFC refrigerants, R-12 and R-502, respectively, used prior to the Montreal Protocol phase out of ozone depleting substances. While the HFC refrigerants are non-ozone depleting, they are strong greenhouse gases, so there has been continued interest in replacing them, particularly in applications with above average refrigerant leakage. Large supermarket refrigeration systems have proven to be particularly difficult to maintain in a leak-tight condition. Refrigerant charge losses of 15% of total charge per year are the norm, making the global warming impact of refrigerant emissions comparable to that associated with the energy consumption of these systems.

  19. Performance Investigation on a Three-Stage Stirling Pulse Tube Cryocooler Operating Below 5K%可达5K以下的三级斯特林型脉管制冷机性能研究

    Institute of Scientific and Technical Information of China (English)

    植晓琴; 邱利民; 甘智华; 曹强; 刘旸

    2012-01-01

    针对当前低温超导电子、军事及空间探测等对液氦温区紧凑、长寿命、高可靠性制冷技术的需求,设计并研制了一台三级斯特林型脉管制冷机。讨论了制冷机第三级的回热器、脉管、调相机构等相关参数的设计,着重分析了液氦温区回热器长度与温度分布的特殊关系。实验中以He-4为工质,第三级在充压0.91 MPa,频率29.9 Hz,输入电功率100 W的工况下获得了4.97 K的最低无负荷温度,有制冷量25 mW@6 K。该结果首次证明了采用He-4为工质、以三级结构的斯特林脉管制冷机实现液氦温区制冷的可行性。%A separate three-stage Stirling pulse tube cryocooler(SPTC) was designed and studied for satisfying the urgent demands of compact,long-life and reliable cryocoolers in the space and military fields.The design of the regenerator,pulse tube and phase shifter of the third stage is discussed in detail.The relationship between the length and the temperature distribution of the regenerator working below liquid helium temperature is emphatically analyzed.Finally,a bottom temperature of 4.97 K was achieved by the SPTC with helium-4 as its working gas,the cooling power was 25 mW at 6.0 K.The third stage was working at 0.91 MPa,29.9 Hz and an input power of 100 W.It is the first time that a temperature below the critical point of helium-4 is achieved by a three-stage SPTC.

  20. HeREF-2003: Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 Cost per participant: 500.- CHF Language: Bilingual English...

  1. HeREF-2003 : Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. • Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 • Cost per participant: 500.- CHF ...

  2. High-Performance, Low Environmental Impact Refrigerants

    Science.gov (United States)

    McCullough, E. T.; Dhooge, P. M.; Glass, S. M.; Nimitz, J. S.

    2001-01-01

    Refrigerants used in process and facilities systems in the US include R-12, R-22, R-123, R-134a, R-404A, R-410A, R-500, and R-502. All but R-134a, R-404A, and R-410A contain ozone-depleting substances that will be phased out under the Montreal Protocol. Some of the substitutes do not perform as well as the refrigerants they are replacing, require new equipment, and have relatively high global warming potentials (GWPs). New refrigerants are needed that addresses environmental, safety, and performance issues simultaneously. In efforts sponsored by Ikon Corporation, NASA Kennedy Space Center (KSC), and the US Environmental Protection Agency (EPA), ETEC has developed and tested a new class of refrigerants, the Ikon (registered) refrigerants, based on iodofluorocarbons (IFCs). These refrigerants are nonflammable, have essentially zero ozone-depletion potential (ODP), low GWP, high performance (energy efficiency and capacity), and can be dropped into much existing equipment.

  3. Optimum operating regimes of common paramagnetic refrigerants

    CERN Document Server

    Wikus, P; Figueroa-Feliciano, E

    2011-01-01

    Adiabatic Demagnetization Refrigerators (ADRs) are commonly used in cryogenic laboratories to achieve subkelvin temperatures. ADRs are also the technology of choice for several space borne instruments which make use of cryogenic microcalorimeters or bolometers {[}1-4]. For these applications, refrigerants with high ratios of cooling capacity to volume, or cooling capacity to mass are usually required. In this manuscript, two charts for the simple selection of the most suitable of several common refrigerants (CAA, CMN, CPA, DGG, FAA, GGG, GLF and MAS) are presented. These graphs are valid for single stage cycles. The selection of the refrigerants is uniquely dependent on the starting conditions of the refrigeration cycle (temperature and magnetic field density) and the desired final temperature. Only thermodynamic properties of the refrigerants have been taken into account, and other important factors such as availability and manufacturability have not been considered. (C) 2011 Elsevier Ltd. All rights reserve...

  4. Not all counterclockwise thermodynamic cycles are refrigerators

    Science.gov (United States)

    Dickerson, R. H.; Mottmann, J.

    2016-06-01

    Clockwise cycles on PV diagrams always represent heat engines. It is therefore tempting to assume that counterclockwise cycles always represent refrigerators. This common assumption is incorrect: most counterclockwise cycles cannot be refrigerators. This surprising result is explored here for quasi-static ideal gas cycles, and the necessary conditions for refrigeration cycles are clarified. Three logically self-consistent criteria can be used to determine if a counterclockwise cycle is a refrigerator. The most fundamental test compares the counterclockwise cycle with a correctly determined corresponding Carnot cycle. Other criteria we employ include a widely accepted description of the functional behavior of refrigerators, and a corollary to the second law that limits a refrigerator's coefficient of performance.

  5. An Optimal Control Approach for an Overall Cryogenic Plant Under Pulsed Heat Loads

    CERN Document Server

    Gómez Palacin, Luis; Blanco Viñuela, Enrique; Maekawa, Ryuji; Chalifour, Michel

    2015-01-01

    This work deals with the optimal management of a cryogenic plant composed by parallel refrigeration plants, which provide supercritical helium to pulsed heat loads. First, a data reconciliation approach is proposed to estimate precisely the refrigerator variables necessary to deduce the efficiency of each refrigerator. Second, taking into account these efficiencies, an optimal operation of the system is proposed and studied. Finally, while minimizing the power consumption of the refrigerators, the control system maintains stable operation of the cryoplant under pulsed heat loads. The management of the refrigerators is carried out by an upper control layer, which balances the relative production of cooling power in each refrigerator. In addition, this upper control layer deals with the mitigation of malfunctions and faults in the system. The proposed approach has been validated using a dynamic model of the cryoplant developed with EcosimPro software, based on first principles (mass and energy balances) and the...

  6. Adsorption refrigeration technology theory and application

    CERN Document Server

    Wang, Ruzhu; Wu, Jingyi

    2014-01-01

    Gives readers a detailed understanding of adsorption refrigeration technology, with a focus on practical applications and environmental concerns Systematically covering the technology of adsorption refrigeration, this book provides readers with a technical understanding of the topic as well as detailed information on the state-of-the-art from leading researchers in the field. Introducing readers to background on the development of adsorption refrigeration, the authors also cover the development of adsorbents, various thermodynamic theories, the design of adsorption systems and adsorption refri

  7. Manganese Nitride Sorption Joule-Thomson Refrigerator

    Science.gov (United States)

    Jones, Jack A.; Phillips, Wayne M.

    1992-01-01

    Proposed sorption refrigeration system of increased power efficiency combines MnxNy sorption refrigeration stage with systems described in "Regenerative Sorption Refrigerator" (NPO-17630). Measured pressure-vs-composition isotherms for reversible chemisorption of N2 in MnxNy suggest feasibility to incorporate MnxNy chemisorption stage in Joule-Thomson cryogenic system. Discovery represents first known reversible nitrogen chemisorption compression system. Has potential in nitrogen-isotope separation, nitrogen purification, or contamination-free nitrogen compression.

  8. Significance of the non-aceatropic binary refrigerants, when used in heat pumps and refrigeration plants

    Energy Technology Data Exchange (ETDEWEB)

    Kruse, H.; Jakobs, R. (Hannover Univ. (Germany, F.R.). Abt. Kaeltetechnik)

    1977-01-01

    The use of binary refrigerants in refrigerating systems and heat pumps is more economical than the use of conventional refrigerants. They are particularly suitable for heat pumps. This is illustrated by a a test plant in the basis of thermodynamic cycles and properties.

  9. Design Guidelines For a Thermoacoustic Refrigerator

    CERN Document Server

    Dhuley, Ram C

    2016-01-01

    Development of refrigerators based on Thermoacoustic technology is a novel solution to the present day need of cooling without causing environmental hazards. With added advantages of absence of moving parts and circulating refrigerants, these devices can attain very low temperatures maintaining a compact size. The present theoretical work is based on theory of linear thermoacoustics[1]. Under the short stack and invicid assumptions, an algorithm for design of a standing wave thermoacoustic refrigerator, with main focus on the stack, is described. A stack is designed for a given cooling requirement of the refrigerator and certain chosen operation parameters.

  10. Thermoeconomic model of a commercial transcritical booster refrigeration system

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Elmegaard, Brian

    2011-01-01

    For cooling applications in supermarkets, booster refrigeration systems operating in both transcritical and subcritical conditions are increasingly used. A thermodynamic model of a transcritical booster refrigeration plant is tailored to match the new generation of commercial refrigeration plants...

  11. Refrigerant charge management in a heat pump water heater

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jie; Hampton, Justin W.

    2016-07-05

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, and methods of managing refrigerant charge. Various embodiments remove idle refrigerant from a heat exchanger that is not needed for transferring heat by opening a refrigerant recovery valve and delivering the idle refrigerant from the heat exchanger to an inlet port on the compressor. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled by controlling how much refrigerant is drawn from the heat exchanger, by letting some refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and various components can be interconnected with refrigerant conduit. Some embodiments deliver refrigerant gas to the heat exchanger and drive liquid refrigerant out prior to isolating the heat exchanger.

  12. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  13. Theoretical and experimental investigations on the cooling capacity distributions at the stages in the thermally-coupled two-stage Stirling-type pulse tube cryocooler without external precooling

    Science.gov (United States)

    Tan, Jun; Dang, Haizheng

    2017-03-01

    The two-stage Stirling-type pulse tube cryocooler (SPTC) has advantages in simultaneously providing the cooling powers at two different temperatures, and the capacity in distributing these cooling capacities between the stages is significant to its practical applications. In this paper, a theoretical model of the thermally-coupled two-stage SPTC without external precooling is established based on the electric circuit analogy with considering real gas effects, and the simulations of both the cooling performances and PV power distribution between stages are conducted. The results indicate that the PV power is inversely proportional to the acoustic impedance of each stage, and the cooling capacity distribution is determined by the cold finger cooling efficiency and the PV power into each stage together. The design methods of the cold fingers to achieve both the desired PV power and the cooling capacity distribution between the stages are summarized. The two-stage SPTC is developed and tested based on the above theoretical investigations, and the experimental results show that it can simultaneously achieve 0.69 W at 30 K and 3.1 W at 85 K with an electric input power of 330 W and a reject temperature of 300 K. The consistency between the simulated and the experimental results is observed and the theoretical investigations are experimentally verified.

  14. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality...... a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, an anthropomorfized archive of a past intimacy and an all-encompassing immersive environment modulating continuously in real space-time....

  15. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... the recovery room, sometimes called the "post-op" (post-operative) room or PACU (post-anesthesia care unit), and ... site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site ...

  16. Heat transfer in forced convection boiling of oil-non-azeotropic binary refrigerant mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Sami, S.M.; Tulej, P.; Fang, L. (Moncton Univ., NB (Canada))

    1993-12-01

    In this paper, the results of the heat transfer, forced convection, boiling characteristics of non-azeotropic refrigerant mixtures and oil are presented. This includes heat transfer coefficients for pure and binary mixtures under boiling conditions outside enhanced surface tubing. Local convective heat transfer coefficients have been determined using a modified Wilson-plot technique. Heat transfer correlations were established as a function of the binary mixture mass flow rate, and oil concentration, as well as key flow parameters. (author)

  17. Numerical simulation on impingement cooling characteristics of pulsed detonation tube%脉冲爆震燃烧室管壁冲击冷却效果的数值研究

    Institute of Scientific and Technical Information of China (English)

    王杏涛; 张靖周; 谭晓茗

    2011-01-01

    According to axial wall temperature distributions on pulsed detonation chamber wall measured from experiment,the quasi-steady state heat flux along the detonation tube with ladder distribution was deduced under a specific frequency.Based on the quasi-steady thermal load,a series of computations were conducted to analyze the cooling effects with array jet impingement.The results show that:the jet velocity from rear rows is bigger than that from the front rows due to end wall effects,the cooling action is stronger near the pulsed detonation tube edge,and the impingement cooling effect is worse in the middle part because the impinging jet is weakened by cross-flow forming from the front rows.Under the same cooling flow Reynolds number at circular passage inlet,the array jet holes are reasonably arranged at middle area of pulsed detonation chamber.When the ratio of the impinging space to diameter is 1.5,the cooling effect seems to be best with uniform axial temperature distribution and lowest peak temperature.And smaller diameter of the cooling holes is also beneficial to improving the cooling effects.%根据实验测量的脉冲爆震燃烧室壁温沿程分布,推算出符合脉冲爆震燃烧室特定频率下的准稳态热流阶梯分布;在此基础上,针对叉排阵列射流冲击冷却的脉冲爆震燃烧室壁面温度分布进行了数值计算.研究表明,由于冷却气流通道端壁效应的影响,靠近爆震燃烧室尾部的射流孔的冲击射流速度较大,热流最大的燃烧室尾部管壁的温度可以得到有效的降低,而燃烧室中部的射流由于受到前排射流形成的横流影响,对管壁的冲击冷却效果较弱,使得壁面温度的峰值向中部转移.在相同的环形冷却通道进口雷诺数下,阵列射流孔宜布置在脉冲爆震燃烧室中部,射流冲击间距比Zn/d=1.5时,管壁的峰值温度最低而且整体的平均温度最小,较小的冲击孔直径对应的冲击冷却效果较好.

  18. Refrigeration and air-conditioning

    CERN Document Server

    Hundy, G H; Welch, T C

    2008-01-01

    Now in its fourth edition, this respected text delivers a comprehensive introduction to the principles and practice of refrigeration. Clear and straightforward, it is designed for students (NVQ/vocational level) and professional HVAC engineers, including those on short or CPD courses. Inexperienced readers are provided with a comprehensive introduction to the fundamentals of the technology. With its concise style yet broad sweep the book covers most of the applications professionals will encounter, enabling them to understand, specify, commission, use and maintain these systems. Many readers w

  19. Energy efficient control of a refrigeration plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2009-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The new idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design o...... and the methods are evaluated with respect to energy efficiency....

  20. Designing a magnet for magnetic refrigeration

    DEFF Research Database (Denmark)

    Bjørk, Rasmus

    of infinite length, are presented. Once it has been determined which properties are desirable for a magnet used in magnetic refrigeration the design of a new magnet is described. This is a high performance cylindrical magnet for use in a new magnetic refrigeration device being built at Risø DTU. This magnet...

  1. Commercial Refrigeration Technology. Florida Vocational Program Guide.

    Science.gov (United States)

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    The program guide for commercial refrigeration technology courses in Florida identifies primary considerations for the organization, operation, and evaluation of a vocational education program. Following an occupational description for the job title for refrigeration mechanic, and its Dictionary of Occupational Titles code, are six sections…

  2. 21 CFR 1250.34 - Refrigeration equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Refrigeration equipment. 1250.34 Section 1250.34 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... SANITATION Food Service Sanitation on Land and Air Conveyances, and Vessels § 1250.34 Refrigeration...

  3. ESO2 Optimization of Supermarket Refrigeration Systems

    DEFF Research Database (Denmark)

    Petersen, Lars Norbert; Madsen, Henrik; Heerup, Christian

    Supermarket refrigeration systems consists of a number of display cases, cooling cabinets and cold rooms connected to a central compressor pack. This configuration saves energy compared to placing a compressor at each cooling site. The classical control setup of a supermarket refrigeration system...

  4. A method of firing a gas filled switching tube

    Energy Technology Data Exchange (ETDEWEB)

    Bryukhanevich G.I.; Kolesov, G.V.; Lebedev, V.B.; Prokhorenko, V.I.

    1984-01-01

    A method is proposed for firing a gas filled switching tube which involves injecting a laser pulse of picosecond duration with an energy level higher than the firing threshold of the switching tube to the spark gap of the tube to be fired. In order to improve the operational stability of the tube, after a time period equal to delta T (with respect to the point where the first laser pulse is fed to the spark gap), a primary supplementary pulse is fed to the gap; the power level of this pulse is selected to be at least half the power level of the first, and the time interval delta T is selected depending on the value of the experimentally determined minimum delay time (t3 min) of the tube during firing by a separately selected primary pulse in a ratio of .5t3 min is less than delta T is less than or equal to t3 min.

  5. A rocket-borne He-3 refrigerator

    Science.gov (United States)

    Duband, L.; Alsop, D.; Lange, A.; Kittel, P.

    A self-contained, recyclable He-3 refrigerator suitable for use in space has been developed. The refrigerator is compact, has no moving parts, and requires only electrical connections and thermal contact in order to operate from a 2 K cold stage. A charcoal adsorption pump is used to efficiently condense and cool the He-3. Sintered copper confines the He-3 to the evaporator in zero-gravity and, in fact, allows the refrigerator to operate upside-down in the laboratory. Mounted on a 2 K cold stage, the refrigerator provides 100 microwatts of cooling power at 346 mK, with a 7 hour hold time. On a 1.5 K cold stage, the lowest temperature achieved is 277 mK. The refrigerator has been vibration tested at 7.5 G amplitude from 30 to 400 Hz and 15 G amplitude from 400 to 2000 Hz.

  6. Detailed analysis of fin-and-tube evaporators

    OpenAIRE

    2009-01-01

    This paper is devoted to the presentation of a new model for fin-and-tube evaporators, focusing on the solid core simulation and its integration with a quasi-homogeneous two-phase flow model for the in-tube refrigerant flow. Special attention is dedicated to separated in-tube flow patterns (stratified, stratified-wavy), because of their importance in liquid overfeed evaporators and the impact on the solid core temperature distribution. The paper presents the solid core formulation and nume...

  7. Prediction of two-phase pressure drop in heat exchanger for mixed refrigerant Joule-Thomson cryocooler

    Science.gov (United States)

    Ardhapurkar, P. M.; Atrey, M. D.

    2015-12-01

    The overall efficiency of a mixed refrigerant Joule-Thomson (MR J-T) cryocooler is governed by the performance of the recuperative heat exchanger. In the heat exchanger, the hot stream of the mixed refrigerant undergoes condensation at high pressure while the cold stream gets evaporated at low pressure. The pressure drop in the low pressure stream is crucial since it directly influences the achievable refrigeration temperature. However, experimental and theoretical studies related to two-phase pressure drop in mixtures at cryogenic temperatures, are limited. Therefore, the design of an efficient MR J-T cryocooler is a challenging task due to the lack of predictive tools. In the present work, the existing empirical correlations, which are commonly used for the prediction of pressure drop in the case of pure refrigerants, evaporating at near ambient conditions, are assessed for the mixed refrigerants. Experiments are carried out to measure the overall pressure drop in the evaporating cold stream of the tube-in-tube helically coiled heat exchanger. The predicted frictional pressure drop in the heat exchanger is compared with the experimental data. The suggested empirical correlations can be used to predict the hydraulic performance of the heat exchanger.

  8. Novel materials for laser refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Hehlen, Markus P [Los Alamos National Laboratory

    2009-01-01

    The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

  9. Sorption Refrigeration / Heat Pump Cycles

    Science.gov (United States)

    Saha, Bidyut Baran; Alam, K. C. Amanul; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao

    Over the past few decades there have been considerable efforts to use adsorption (solid/vapor) for cooling and heat pump applications, but intensified efforts were initiated only since the imposition of international restrictions on the production and use of CFCs (chlorofluorocarbons) and HCFCs (hydrochlorofluorocarbons). Up to now, only the desiccant evaporative cooling system of the open type has achieved commercial use, predominantly in the United States. Closed-type adsorption refrigeration and heat pump systems are rarely seen in the market, or are still in the laboratory testing stage. Promising recent development have been made in Japan for the use of porous metal hydrides and composite adsorbents. In this paper, a short description of adsorption theories along with an overview of present status and future development trends of thermally powered adsorption refrigeration cycles are outlined putting emphasis on experimental achievements. This paper also addressed some advanced absorption cycles having relatively higher COP, and also summarizes fundamental concepts of GAX cycles and various GAX cycles developed for heat pump applications.

  10. Thermofluid Analysis of Magnetocaloric Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Gluesenkamp, Kyle R [ORNL; Vineyard, Edward Allan [ORNL; Benedict, Michael [GE Appliances

    2014-01-01

    While there have been extensive studies on thermofluid characteristics of different magnetocaloric refrigeration systems, a conclusive optimization study using non-dimensional parameters which can be applied to a generic system has not been reported yet. In this study, a numerical model has been developed for optimization of active magnetic refrigerator (AMR). This model is computationally efficient and robust, making it appropriate for running the thousands of simulations required for parametric study and optimization. The governing equations have been non-dimensionalized and numerically solved using finite difference method. A parametric study on a wide range of non-dimensional numbers has been performed. While the goal of AMR systems is to improve the performance of competitive parameters including COP, cooling capacity and temperature span, new parameters called AMR performance index-1 have been introduced in order to perform multi objective optimization and simultaneously exploit all these parameters. The multi-objective optimization is carried out for a wide range of the non-dimensional parameters. The results of this study will provide general guidelines for designing high performance AMR systems.

  11. Stimulation and experimental research on a 20K single stage Stirling-type pulse tube cooler%20K温区单级斯特林型脉管制冷机研究

    Institute of Scientific and Technical Information of China (English)

    王海敏; 戴巍; 王晓涛; 罗二仓

    2013-01-01

    为进一步研究降低20 K温区单级斯特林型脉管制冷机关键部件中损失的方法,提高整机性能,采用计算软件Sage对制冷机进行模拟.通过实验结果与Sage计算的对比对模拟程序的有效性进行了考察,并从调相系统结构及水冷器结构方面寻找优化途径.结果表明,在单纯使用惯性管气库调相时,计算最低制冷温度比实验值低9K左右;当采用双向进气与惯性管调相组合时,计算同实验结果基本一致.最后引入虚拟的振子阻尼调相机构对制冷机的最佳性能进行研究,计算表明在这种调相结构下,制冷机的无负荷制冷温度及30 K时的制冷量均可以得到比双向进气加惯性管组合调相更优的结果.%A 20 K Stirling-type pulse tube cooler system was developed, whose lowest cold head temperature was 22.7 K. To optimize the system performance further more, Sage software was used to do the simulation and introduce the results. This passage shows the effectiveness of Sage by comparing experimental and results computation. Results show that with inertance-reservoir as the phase shifter, the computational result is 9 K lower than that of the experiment. In case of using double-inlet, all results match well. Finally, a virtual phase shifter was introduced to optimize the system. Computation indicates that under this mode of phase shifter, both the no-load cryogenic temperature and cryogenic power at 30 K can get better performance than when the cooler is under inertance tube and double inlet phase shifters.

  12. Effect of Fin Geometry on Condensation of R134a in a Staggered Bundle of Horizontal Finned Tubes

    Science.gov (United States)

    Honda, Hiroshi; Takata, Nobuo; Takamatsu, Hiroshi; Kim, Jeongsk; Usami, Keiichiro

    Experimental results are presented that show the effect of fin geometry on condensation of refrigerant R134a in a staggered bundle of horizontal fined tubes. Two kinds of conventional low-fin tubes and three kinds of three-dimensional fin tubes were tested. The refrigerant mass velocity ranged from 8 to 23 kg/m2s and the condensation temperature difference from 1.5 to 12 K. In most cases, the highest performance was obtained by one of the three-dimensional fin tubes. In the case of high mass velocity and high film Reynolds number, however, the highest performance was obtained by one of the low-fin tubes. The results were compared with previous experimental results for bundles of smooth tubes and low-fin tubes.

  13. The new exchangers in refrigeration and air, conditioning applications

    Energy Technology Data Exchange (ETDEWEB)

    Marvillet, Ch. [CEA, 38 - Grenoble (France). GRETh

    1997-12-31

    The investigation carried out by the `heat exchangers` network has revealed a number of points which should be noted here at the beginning of this presentation. It has been observed that most of today`s products (fin and tube heat exchangers) are designed along traditional lines. However despite this `conservatism`, a lot of attention is found on the technical and innovative techniques used in other areas of the world (particularly in Japan). Moreover, some of these innovative techniques (micro fin tubes, louvered fins) tend to be more frequently applied than others, and their gradual introduction into products which are `made in the EEC` is to be expected. The purpose of this paper is to respond, at least partially, to the interest shown by the industries contacted. during this investigation in these new techniques. In the first chapter, an overview of the information available today on high performance thermal heat exchange surfaces will be given. Micro-fin tubes and louvered fins will be the two surfaces considered in the first part of this document. According to this investigation, the fin and tube heat exchanger remains the only product available today for evaporating and condensing refrigerant applications using air as the fluid to be treated. Other technological solutions exist, however; brazed fin and plate heat exchangers commonly used in applications where compactness is an essential quality will be examined in the second part of this document. Moreover, the use of fluids which will replace CFCS in the years to come, and the possible comeback of ammonia will certainly have consequences on the design of evaporators and condensers. In the third part of this document the effects of these changes on fin and tube heat exchangers will be evaluated, and the first published results of the use of substitution fluids will be discussed. (author) 16 refs.

  14. Pulse on Pulse

    DEFF Research Database (Denmark)

    Schmidt, Ulrik; Carlson, Merete

    2012-01-01

    and pulsating ‘room’. Hence, the visitors in Pulse Room are invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic ‘rhythm of life’) and instants of pure material processuality......“Pulse on Pulse” investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006-) by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy...... of the visitor’s beating heart to the blink of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the blinking light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant...

  15. A review of carbon dioxide as a refrigerant in refrigeration technology

    Directory of Open Access Journals (Sweden)

    Paul Maina

    2015-09-01

    Full Text Available Tough environmental laws and stringent government policies have revolutionised the refrigeration sector, especially concerning the cycle fluid known as the refrigerant. It has been observed that only natural refrigerants are environmentally benign. When other refrigerant qualities are considered, especially those relating to toxicity and flammability, carbon dioxide emerges as the best among the natural refrigerants. However, carbon dioxide based refrigerants are not without drawbacks. Even though the use of R744 a carbon dioxide based refrigerant gas has solved the direct effect of emissions on the environment, studies to investigate the indirect effects of these systems are needed. Improvement in existing technical solutions and the formulation of additional solutions to existing R744 refrigeration problems is paramount if this technology is to be accepted by all, especially in areas with warm climates. National policies geared to green technologies are important to clear the way and provide support for these technologies. It is clear that carbon dioxide is one of the best refrigerants and as environmental regulations become more intense, it will be the ultimate refrigerant of the future.

  16. Solid cartridge for a pulse weld forming electrode and method of joining tubular members

    Energy Technology Data Exchange (ETDEWEB)

    Bonnen, John Joseph Francis; Golovashchenko, Sergey Fedorovich; Mamutov, Alexander; Maison, Lloyd Douglas; Dawson, Scott Alwyn; deVries, James

    2016-02-23

    A cartridge assembly is disclosed for a pulse welding a first tube supported on a mandrel to a second tube. An outer tool is assembled over the second tube and a stored charge is discharged in the cartridge assembly. The cartridge comprises an annular conductor and a solid casing enveloping the conductor. The stored charge is electrically connected to the conductor and discharged through the conductor to compress the second tube and pulse weld the second tube to the first tube.

  17. Effect of Spacing between Coils in Pulsed Remote Field Eddy Current Testing for Ferromagnetic Tube%铁磁性管道脉冲远场涡流检测中线圈间距影响

    Institute of Scientific and Technical Information of China (English)

    喻星星; 付跃文; 蔚道祥; 徐进军; 江茫

    2015-01-01

    依据分析检测原理,对铁磁性管道脉冲远场涡流检测时激励线圈与接收线圈之间的间距对缺陷检测结果的影响进行试验研究. 给出了试验所得的检测线圈衰减曲线、检测灵敏度曲线以及感应电压剖面曲线. 对材质为J55,尺寸为?73. 8 mm × 5. 7 mm的油管进行检测试验,结果显示当线圈间距由60 mm逐步增加到210 mm时,检测线圈感应电压衰减曲线发生明显变化,缺陷检测灵敏度|Δu|/u由0. 35逐步增加到143,最高灵敏度对应的接收时间点前移2 511μs;但线圈间距增加到240 mm时,灵敏度|Δu|/u降为73. 试验结果表明:线圈间距为210 mm时,其检测灵敏度最佳. 该研究对脉冲远场涡流检测探头的设计具有参考价值.%Based on analysis of the principle, experiments are designed and performed to study the effect of the spacing between exciting coil and receiving coil on the detection sensitivity in pulsed remote field eddy current testing for ferromagnetic tube. Voltage decay curves of the receiving coil, sensitivity-time curves and time slices of voltage are given in the experiments. J55 oil well tube sample with a gauge of ?73. 8 mm × 5. 7 mm is inspected and the experimental results show that the increase of the spacing between the exciting coil and the receiving coil will cause several changes. When the spacing varies from 60 mm to 210 mm, voltage descending curves of the receiving coil have significant changes, detection sensitivity |Δu|/u varies from 0. 35 to 143 and the peak of detection sensitivity moves forward 2 511 μs, but detection sensitivity |Δu|/u falls to 73 when coil spacing increases to 240 mm. The experimental results show that the detection sensitivity is best when the distance reaches 210 mm. The results are of help to the design of pulsed remote field eddy current probe.

  18. Experimental investigation of the ecological hybrid refrigeration cycle

    Science.gov (United States)

    Cyklis, Piotr; Kantor, Ryszard; Ryncarz, Tomasz; Górski, Bogusław; Duda, Roman

    2014-09-01

    The requirements for environmentally friendly refrigerants promote application of CO2 and water as working fluids. However there are two problems related to that, namely high temperature limit for CO2 in condenser due to the low critical temperature, and low temperature limit for water being the result of high triple point temperature. This can be avoided by application of the hybrid adsorption-compression system, where water is the working fluid in the adsorption high temperature cycle used to cool down the CO2 compression cycle condenser. The adsorption process is powered with a low temperature renewable heat source as solar collectors or other waste heat source. The refrigeration system integrating adsorption and compression system has been designed and constructed in the Laboratory of Thermodynamics and Thermal Machine Measurements of Cracow University of Technology. The heat source for adsorption system consists of 16 tube tulbular collectors. The CO2 compression low temperature cycle is based on two parallel compressors with frequency inverter. Energy efficiency and TEWI of this hybrid system is quite promising in comparison with the compression only systems.

  19. Experimental investigation of the ecological hybrid refrigeration cycle

    Directory of Open Access Journals (Sweden)

    Cyklis Piotr

    2014-09-01

    Full Text Available The requirements for environmentally friendly refrigerants promote application of CO2 and water as working fluids. However there are two problems related to that, namely high temperature limit for CO2 in condenser due to the low critical temperature, and low temperature limit for water being the result of high triple point temperature. This can be avoided by application of the hybrid adsorption-compression system, where water is the working fluid in the adsorption high temperature cycle used to cool down the CO2 compression cycle condenser. The adsorption process is powered with a low temperature renewable heat source as solar collectors or other waste heat source. The refrigeration system integrating adsorption and compression system has been designed and constructed in the Laboratory of Thermodynamics and Thermal Machine Measurements of Cracow University of Technology. The heat source for adsorption system consists of 16 tube tulbular collectors. The CO2 compression low temperature cycle is based on two parallel compressors with frequency inverter. Energy efficiency and TEWI of this hybrid system is quite promising in comparison with the compression only systems.

  20. 46 CFR 151.40-11 - Refrigeration systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigeration systems. 151.40-11 Section 151.40-11... Refrigeration systems. (a) Boiloff systems. The venting of cargo boiloff to atmosphere shall not be used as a...) Vapor compression, tank refrigeration, and secondary refrigeration systems: The required...

  1. 46 CFR 58.20-15 - Installation of refrigerating machinery.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Installation of refrigerating machinery. 58.20-15... AND AUXILIARY MACHINERY AND RELATED SYSTEMS Refrigeration Machinery § 58.20-15 Installation of refrigerating machinery. (a) Where refrigerating machines are installed in which anhydrous ammonia is used as...

  2. New refrigeration system using CO2 vapor-solid as refrigerant

    Institute of Scientific and Technical Information of China (English)

    Dongping HUANG; Guoliang DING; Hans QUACK

    2008-01-01

    A refrigerant must be in the vapor-liquid phase in a vapor-compression refrigeration system, therefore, CO2 cannot be used as a refrigerant for temperatures lower than -56℃ because solid CO2 will form under the triple point temperature of -56℃. A refrigeration system with CO2 vapor-solid particles as refrigerant is put forward, by which a temperature lower than the triple point is achieved. An adjustable nozzle, a sublimator, a high-pressure regulating valve and a low-pressure regulat-ing valve are used to replace the conventional evaporator. Theoretical cycle analysis of the refrigeration system shows that its COP can be 50% higher than that of the conventional one.

  3. Mathematical analysis of a Vuilleumier refrigerator.

    Science.gov (United States)

    Sherman, A.

    1971-01-01

    A comprehensive analysis of the Vuilleumier refrigerator was conducted. This analysis includes the effects of nonisothermal gas heat addition and rejection, hot and cold regenerator inefficiencies, conduction losses, and gas leakage losses. A computer program was written which solves the equations resulting from the analysis. The program calculates internal pressures, temperatures, and gas flow rates as functions of refrigerator crank angle, as well as overall refrigerator cooling load and power input. Comparisons between the program results and available data show good agreement, with a marked improvement over the predictions of the ideal model.

  4. Two-phase flow in refrigeration systems

    CERN Document Server

    Gu, Junjie; Gan, Zhongxue

    2013-01-01

    Two-Phase Flow in Refrigeration Systems presents recent developments from the authors' extensive research programs on two-phase flow in refrigeration systems. This book covers advanced mass and heat transfer and vapor compression refrigeration systems and shows how the performance of an automotive air-conditioning system is affected through results obtained experimentally and theoretically, specifically with consideration of two-phase flow and oil concentration. The book is ideal for university postgraduate students as a textbook, researchers and professors as an academic reference book, and b

  5. A Ross-Stirling spacecraft refrigerator

    Science.gov (United States)

    Walker, G.; Scott, M.; Zylstra, S.

    A spacecraft refrigerator was investigated capable of providing cooling for storage of food and biological samples in the temperature range 0-20 F with cooling capacity in the range of 1 to 2 kW, operating for long periods with great reliability. The system operated on the Stirling refrigeration cycle using the spacecraft life-support gases as the working fluid. A prototype spacecraft Stirling refrigerator was designed, built, and tested with air as the working fluid. The system performance was satisfactory, meeting the requirements specified above. Potential applications for the prototype unit are mentioned.

  6. Mathematical analysis of a Vuilleumier refrigerator.

    Science.gov (United States)

    Sherman, A.

    1971-01-01

    A comprehensive analysis of the Vuilleumier refrigerator was conducted. This analysis includes the effects of nonisothermal gas heat addition and rejection, hot and cold regenerator inefficiencies, conduction losses, and gas leakage losses. A computer program was written which solves the equations resulting from the analysis. The program calculates internal pressures, temperatures, and gas flow rates as functions of refrigerator crank angle, as well as overall refrigerator cooling load and power input. Comparisons between the program results and available data show good agreement, with a marked improvement over the predictions of the ideal model.

  7. Classification of refrigerants; Classification des fluides frigorigenes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This document was made from the US standard ANSI/ASHRAE 34 published in 2001 and entitled 'designation and safety classification of refrigerants'. This classification allows to clearly organize in an international way the overall refrigerants used in the world thanks to a codification of the refrigerants in correspondence with their chemical composition. This note explains this codification: prefix, suffixes (hydrocarbons and derived fluids, azeotropic and non-azeotropic mixtures, various organic compounds, non-organic compounds), safety classification (toxicity, flammability, case of mixtures). (J.S.)

  8. A versatile magnetic refrigeration test device.

    Science.gov (United States)

    Bahl, C R H; Petersen, T F; Pryds, N; Smith, A

    2008-09-01

    A magnetic refrigeration test device has been built and tested. The device allows variation and control of many important experimental parameters, such as the type of heat transfer fluid, the movement of the heat transfer fluid, the timing of the refrigeration cycle, and the magnitude of the applied magnetic field. An advanced two-dimensional numerical model has previously been implemented in order to help in the optimization of the design of a refrigeration test device. Qualitative agreement between the results from model and the experimental results is demonstrated for each of the four different parameter variations mentioned above.

  9. A versatile magnetic refrigeration test device

    DEFF Research Database (Denmark)

    Bahl, Christian Robert Haffenden; Petersen, Thomas Frank; Pryds, Nini

    2008-01-01

    A magnetic refrigeration test device has been built and tested. The device allows variation and control of many important experimental parameters, such as the type of heat transfer fluid, the movement of the heat transfer fluid, the timing of the refrigeration cycle, and the magnitude...... of the applied magnetic field. An advanced two-dimensional numerical model has previously been implemented in order to help in the optimization of the design of a refrigeration test device. Qualitative agreement between the results from model and the experimental results is demonstrated for each of the four...

  10. PIPER Continuous Adiabatic Demagnetization Refrigerator

    Science.gov (United States)

    Kimball, Mark O.; Shirron, Peter J.; Canavan, Edgar R.; James, Bryan L.; Sampson, Michael A.; Letmate, Richard V.

    2017-01-01

    We report upon the development and testing of a 4-stage adiabatic demagnetization refrigerator (ADR) capable of continuous cooling at 0.100 Kelvin. This cooler is being built to cool the detector array aboard NASA's Primordial Inflation Polarization Explorer (PIPER) observatory. The goal of this balloon mission is to measure the primordial gravitational waves that should exist if the theory of cosmological inflation is correct. At altitude, the ADR will hold the array of transition-edge sensors at 100 mK continuously while periodically rejecting heat to a 1.2 K pumped helium bath. During testing on ground, the array is held at the same temperature but heat is rejected to a 4.2 K helium bath indicating the flexibility in this coolers design.

  11. Ferroelectric Stirling-Cycle Refrigerator

    Science.gov (United States)

    Jalink, Antony, Jr. (Inventor); Hellbaum, Richard F. (Inventor); Rohrbach, Wayne W. (Inventor)

    1999-01-01

    A Stirling-cycle refrigerator has a three-pump configuration and pumping sequence, in which one pump serves as a compressor. one pump serves as an expander, and one pump serves as a displacer. The pumps are ferroelectrically actuated diaphragm pumps which are coordinated by synchronizing the ferroelectric-actuator voltages in such a way that the net effect of the displacer is to reduce the deleterious effect of dead space; that is, to circulate a greater fraction of the working fluid through the heat exchangers than would be possible by use of the compressor and expander alone. In addition. the displacer can be controlled separately to make the flow of working fluid in the heat exchangers turbulent (to increase the rate of transfer of heat at the cost of greater resistance to flow) or laminar (to decrease the resistance to flow at the cost of a lower heat-transfer rate).

  12. Quantum-enhanced absorption refrigerators

    CERN Document Server

    Correa, Luis A; Alonso, Daniel; Adesso, Gerardo

    2014-01-01

    Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step t...

  13. Heat transfer measurements on smooth and finned tubes in a standard apparatus for boiling experiments. Waermeuebergangsmessungen an Glatt- und Rippenrohren in einer Standardapparatur fuer Siedeversuche

    Energy Technology Data Exchange (ETDEWEB)

    Fath, W.

    1986-07-28

    The use of Rankine cycles with refrigerants or other organic working fluids for waste heat recovery has been a matter of discussion lately. The evaporating pressure is higher in these systems than in conventional application of finned tubes, so the problems of heat transfer in nucleate boiling on finned tubes are investigated here. Measurements were made on smooth and finned tubes and on surface-treated smooth and finned tubes. Refrigerant R-22 was used for the experiments; the measurements cover a wide range of pressures. (HAG).

  14. Design and analysis of a 5-MW vertical-fluted-tube condenser for geothermal applications

    Energy Technology Data Exchange (ETDEWEB)

    Llewellyn, G.H.

    1982-03-01

    The design and analysis of an industtial-sized vertical-fluted-tube condenser. The condenser is used to condense superheated isobutane vapor discharged from a power turbine in a geothermal test facility operated for the US Department of Energy. The 5-MW condenser has 1150 coolant tubes in a four-pass configuration with a total heat transfer area of 725 m/sup 2/ (7800 ft/sup 2/). The unit is being tested at the Geothermal Components Test Facility in the Imperial Valley of East Mesa, California. The condenser design is based on previous experimental research work done at the Oak Ridge National Laboratory on condensing refrigerants on a wide variety of single vertical tubes. Condensing film coefficients obtained on the high-performance vertical fluted tubes in condensing refrigerants are as much as seven times greater than those obtained with vertical smooth tubes that have the same diameter and length. The overall heat transfer performance expected from the fluted tube condenser is four to five times the heat transfer obtained from the identical units employing smooth tubes. Fluted tube condensers also have other direct applications in the Ocean Thermal Energy Conversion (OTEC) program in condensing ammonia, in the petroleum industry in condensing light hydrocarbons, and in the air conditioning and refrigeration industry in condensing fluorocarbon vapors.

  15. Health effects among refrigeration repair workers exposed to fluorocarbons.

    OpenAIRE

    1986-01-01

    Refrigeration repair workers may be intermittently exposed to fluorocarbons and their thermal decomposition products. A case of peripheral neuropathy (distal axonopathy) in a commercial refrigeration repairman prompted an epidemiological investigation of the health of refrigeration repair workers. No additional cases of peripheral neuropathy were identified among the 27 refrigeration repair workers studied. A reference group of 14 non-refrigeration repair workers was also studied. No differen...

  16. Chest tube insertion

    Science.gov (United States)

    ... tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Kirsch TD, Sax J. Tube thoracostomy. In: Roberts JR, ed. Roberts and ... . 6th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap 10.

  17. Jejunostomy feeding tube

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000181.htm Jejunostomy feeding tube To use the sharing features on this ... vomiting Your child's stomach is bloated Alternate Names Feeding - jejunostomy tube; G-J tube; J-tube; Jejunum ...

  18. Exergetic sustainability evaluation of irreversible Carnot refrigerator

    Science.gov (United States)

    Açıkkalp, Emin

    2015-10-01

    Purpose of this paper is to assess irreversible refrigeration cycle by using exergetic sustainability index. In literature, there is no application of exergetic sustainability index for the refrigerators and, indeed, this index has not been derived for refrigerators. In this study, exergetic sustainability indicator is presented for the refrigeration cycle and its relationships with other thermodynamics parameters including COP, exergy efficiency, cooling load, exergy destruction, ecological function and work input are investigated. Calculations are conducted for endoreversible and reversible cycles and then results obtained from the ecological function are compared. It is found that exergy efficiency, exergetic sustainable index reduce 47.595% and 59.689% and rising at the COP is 99.888% is obtained for endoreversible cycle. Similarly, exergy efficiency and exergetic sustainability index reduce 90.163% and 93.711% and rising of the COP is equal to 99.362%.

  19. ENERGY STAR Certified Commercial Refrigerators and Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Commercial Refrigerators and Freezers that are...

  20. COMPUTER SIMULATION OF A STIRLING REFRIGERATING MACHINE

    Directory of Open Access Journals (Sweden)

    V.V. Trandafilov

    2015-10-01

    Full Text Available In present numerical research, the mathematical model for precise performance simulation and detailed behavior of Stirling refrigerating machine is considered. The mathematical model for alpha Stirling refrigerating machine with helium as the working fluid will be useful in optimization of these machines mechanical design. Complete non-linear mathematical model of the machine, including thermodynamics of helium, and heat transfer from the walls, as well as heat transfer and gas resistance in the regenerator is developed. Non-dimensional groups are derived, and the mathematical model is numerically solved. Important design parameters are varied and their effect on Stirling refrigerating machine performance determined. The simulation results of Stirling refrigerating machine which include heat transfer and coefficient of performance are presented.