WorldWideScience

Sample records for pulse polarographic determination

  1. Selenium and Trace Element Distribution in Astragalus Plants: Developing a Differential Pulse Polarographic Method for Their Determination

    OpenAIRE

    SOMER, Güler; ÇALIŞKAN, A. Cengiz

    2007-01-01

    Astragalus plants have a wide range of applications in pharmaceuticals (gum tragacanth), as thickening agents in foods, and may have applications in controlling cancer cells. They are used as feed for animals and they are indicator plants for selenium. Because of their use in health-related areas it is very important to determine their selenium and trace element content with high accuracy. A new differential pulse polarographic method was established for trace element determination (...

  2. Polarographic determination of ruthenium

    International Nuclear Information System (INIS)

    Li Jifu; Duan Shirong; Wu Xi

    1989-01-01

    It is suggested to use 0.5 mol/l HClO 4 -0.5 mol/l NaNO 3 -0.1 mol/l NaClO 4 as supporting electrolyte for determining ruthenium. In the supporting electrolyte there is a clear polarographic wave of ruthenium (IV) at -0.8 V vs. SCE. The wave height of ruthenium(IV) is linear in the range from 0.1 to 0.4 μg. ml -1 . The effect of the component of supporting electroylte and the other ion in the samples on the measurement of ruthenium are studied. The analysis methods for measuring ruthenium in both acidic or basic imitative radioactive waste solutions which is used in study of glass solidification are worked out. Imitative samples are analysised

  3. Differential pulse polarographic determination of molybdenum (VI) in phosphoric medium by benzoin alpha oxime

    International Nuclear Information System (INIS)

    Chergouche, S.

    1992-02-01

    The extraction of Molybdenum (VI) using both 4-Methylpentane-2-one (hexone) and chloroform dissolved Benzoin-alpha-oxime has been investigated in order to develop a simple and sensitive polarographic method allowing the analysis of Molybdenum (VI) contained in industrial phosphoric acid produced in ANNABA (Eastern Algeria). The investigation takes into account various parameters such as: The stirring time, solvent rate, the number of stages ... as well as the organic phase conditioning during the polarographic analysis

  4. Differential pulse polarographic determination of trace antimony in standard biological samples after preconcentration using 2-nitroso-1-naphthol-4-sulfonic acid

    International Nuclear Information System (INIS)

    Taher, M. A.

    2003-01-01

    A highly selective, rapid and economical differential polarographic method has been developed for the determination of trace amounts of antimony in various standard alloys and biological samples after of its 2-naphthol-4 sulfonic acid tetradecyl dimethylbenzylammonium chloride on microcrystalline naphthalene in the ph range of 7.5-11.0. After filtration, the solid mass is shaken with 8-10 ml of 1 M hydrochloric acid (with preconcentration factor of 10) and antimony is determined by differential pulse polarography. Antimony can alternatively be quantitatively absorbed on 2-nitroso-1-naphthol-4-sulfonic acid tetradecyl dimethylbenzylammonium-naphthalene absorbed packed in a column (with preconcentration factor of 30) and determined similarly. In this case, 1.5 μg of antimony can be concentrated in a column from 300 ml of aqueous sample, where its concentration is as low as 5 ng/ml. Characterization of the electro active process included an examination of the degree of reversibility. The results show that the irreversibility of antimony. Various parameters such as the effect of ph, volume of aqueous phase, HCl concentration, reagent concentration, naphthalene concentration, shaking time and interference of a number of metal ions on the determination of antimony have been studied in detail to optimize the conditions for determination in standard alloys and standard biological samples

  5. Polarographic determination of trace amounts of thorium

    Energy Technology Data Exchange (ETDEWEB)

    Zaofan Zhao; Xiaohua Cai; Peibiao Li; Handong Yang

    1986-07-01

    A sensitive linear-sweep polarographic method for the determination of thorium is described. It is based on the thorium complex with Xylidyl Blue I (XBI) in a medium containing ethylenediamine, 1, 10-phenanthroline, oxalic acid and ninhydrin, at pH 10.5-11.5. The complex has been proved to be Th(XBI)/sub 2/, with log ..beta..'=9.6. The method can be used to determine trace amounts of thorium over the range 3.5x10/sup -8/-3x10/sup -6/M. The detection limit is 1x10/sup -8/M. A solvent extraction procedure is necessary to eliminate interference from several cations. The method has been applied to determination of traces of thorium in minerals, with good results.

  6. Preconcentration of trace uranium from seawater with solid phase extraction followed by differential pulse polarographic determination in chloroform eluate

    International Nuclear Information System (INIS)

    Dojozan, Dj.; Pournaghi-Azar, M.H.; Toutounchi-Asr, J.

    1998-01-01

    In the present study, an effective method is presented for the separation and preconcentration of uranium (VI) by solid phase extraction (SPE). For this purpose, U(VI) oxinate is formed by the reaction of U(VI) with 8-hydroxyquinoline and adsorbed onto the octylsilane (C-8) SPE cartridge. The analyte is completely eluted with chloroform and determined by differential pulse polarography. The SPE conditions were optimized by evaluating the effective factors such as pH, oxine concentration, type and concentration of buffer and masking agent. By the proposed method a preconcentration factor of more than 100 was achieved. The average recovery of uranium (VI) oxinate (0.1 mg l -1 ) was 99.8%. The relative standard deviation was 1.6% for seven replicate determinations of uranyl ion in the solution with a concentration 20 μg l -1 . Some concomitant ions such as Ca +2 , Mg +2 and Fe +3 which interfere in extraction or determination process of uranium were masked with EDTA in aqueous phase during the extraction process. The proposed method was successfully used for the determination of uranium in Caspian Sea and Persian Gulf water samples

  7. Determination of tin (II) in radiopharmaceutical kits by polarographic method

    International Nuclear Information System (INIS)

    Aungurarat, A.; Thuntawewadthananon, T.

    1996-01-01

    Radiopharmaceutical kit is a diagnostic compound which contains Stannous (II) as a reducing agent. The quantity of Stannous (II) is depended on the type of kits. So the quantity of Stannous (II) is determined by polarographic method with Differential Pulse Voltammetry (D P Mode) in which a saturated calomel electrode is used as anode and a dropping mercury electrode is used as cathode. Both of electrodes are immerged in the premixed solution of supporting electrolyte and analytical Stannous (II). The Stannous (II) is determined by direct method Stannous (II) is analyzed in the form of Stannous; Sn 2 + itself, and indirect method Stannous (II) is analyzed in the form of S tannic; Sn 4+ (Sn 2+ , + N H 4 + ----> Sn 4+ ). Both methods are done at polarographic half wave potential -470 and -520 mV respectively. The Limit of Detection (LOD) of the direct method is 1.9445 micro g and indirect method is 1.3018 micro g. The result received from indirect method is much more accurate than the direct method (Sn 2+ ). The accuracy of the direct method is about 97.5-102.5% recovery

  8. Polarographic determination of selenium in indium

    International Nuclear Information System (INIS)

    Kaplan, B.Ya.; Mikheeva, V.A.; Priz, N.B.

    1978-01-01

    The procedure of determining nx10 -6 % Se in indium after concentrating in an elemental form on arsenic and sulphur has been developed. The selenium content is determined by inversion a.c. polarography on a sulphuric-acid background in the presence of Cu(2), potassium bichromate, and sodium pyrophosphate. 5.7x10 -6 % Se in metal indium has been determined by this procedure, the mean standard deviation being Sr=0.26

  9. Polarographic determination of uranium dioxide stoichiometry

    International Nuclear Information System (INIS)

    Viguie, J.; Uny, G.

    1966-10-01

    The method described allows the determination of small deviations from stoichiometry for uranium dioxide. It was applied to the study of surface oxidation of bulk samples. The sample is dissolved in phosphoric acid under an argon atmosphere; U(VI) is determined by polarography in PO 4 H 3 4.5 N - H 2 SO 4 4 N. U(IV) is determined by potentiometry. The detection limit is UO 2,0002 . The accuracy for a single determination at the 95% confidence level is ±20 per cent for samples with composition included between UO 2,001 and UO 2,01 . (authors) [fr

  10. Polarographic determination of indium and thallium iodides in phosphor tablets

    International Nuclear Information System (INIS)

    Babich, G.A.; Dzhurka, G.F.; Kozhushko, G.M.; Kravtsova, K.F.; Magda, V.I.

    1984-01-01

    The technique of polarographic determination of indium and thallium iodides in phosphor tablets without preliminary separation of elements was developed. Mercury-dropping electrode was used as an indicator, and saturated calomel electrode was used as an auxiliary electrode. A recording of reduction currents was performed in the potential interval from -0.25 up to 1.15 V at potential sweep speed of 200 mV/min. Optimum conditions of sample acidic decomposition and polarography were presented. A solution of ethylene diamine (0.5 M), of ammonia (0.25 M) and of potassium chloride (0.05 M) served as a background electrolyte. The suggested technique allows one to determine component contents in tablets with a satisfactory accuracy. A period of one tablet analysis constitutes 1.5 h

  11. Estudo polarográfico sobre a determinação de Fe(III utilizando-se a técnica da polarografia de pulso diferencial Polarographic study about the determination of Fe(III using the technique of differencial pulse polarography

    Directory of Open Access Journals (Sweden)

    Luiz Manoel Aleixo

    2001-12-01

    Full Text Available A differential pulse polarographic study with the objective to determine iron (III in presense of copper (II in a supporting electrolyte based on citrate - EDTA was made. The best experimental conditions found were a supporting electrolyte of citrate 0.25 mol L-1, EDTA 0.050 mol L-1 and KNO3 0.50 mol L-1, pH 5.00. In this media iron (III showed a polarographic peak in -0.08 V and the copper (II in -0.34 V, both vs. Ag/AgCl (saturated KCl. Thus, a analytical method was developed and applied to determine iron (III in brass alloy, a matrix were copper is in large excess over iron. The results obtained showed no interference of copper in the iron determination. The value of 0.21% of iron in the sample alloy composition was obtained and the method was validated by atomic absortion and recovery test, and the results exhibited a good agreement with the proposed method.

  12. Simultaneous polarographic determination of micro amounts of vanadium(V) and molybdenum(VI)

    International Nuclear Information System (INIS)

    Rao, V.S.N.; Rao, S.B.

    1979-01-01

    A simple and sensitive polarographic method has been developed for the determination of micro quantities of vanadium(V) and molybdenum(VI), based on the reduction of bromate, which is catalysed by these metal ions in the presence of 2,4-dihydroxyacetophenone oxime. Interference by various cations and anions has been investigated. (author)

  13. Polarographic study of acrolein and its determination by flow injection with amperometric detection at a mercury electrode.

    Science.gov (United States)

    Naranjo Rodríguez, I; Muñoz Leyva, J A; Hidalgo Hidalgo de Cisneros, J L

    1996-07-01

    A study of the electrochemical behavior of acrolein at a dropping mercury electrode using different polarographic techniques is described. Theoretical studies of the reversibility of the wave of acrolein were carried out using two different polarographic techniques: direct current tast and differential pulse. Differential pulse polarography may be used to determine acrolein concentration in a Britton-Robinson buffer solution of pH 10 in the ranges 2 x 10(-7)10(-8) and 5 x 10(-8)-10(-4) mol dm(-3) and a coefficient of variation of 1.7% for a concentration of 10(-5)mol dm(-3). A flow injection method with amperometric detection at a potential of -1.4V using a mercury electrode is also described. Before each injection, any drop hanging from the tip of the capillary needs to be dislodged and a new electrode drop dispensed; three different drop sizes were tested. A linear relationship between peak intensity and acrolein concentration was obtained in the range 10(-5)-10(-7) mol dm(-3), with a detection limit of 9.8 x 10(-8) mol dm(-) 3 and a coefficient of variation of 2.9% for a 2 x 10(-7) mol dm(-3) concentration. Several organic and inorganic species were tested in order to ascertain whether they interfered with the signal for acrolein. The proposed methods were applied to the determination of acrolein in seawater samples.

  14. Polarographic determination of Sn (II) and total Sn in PYRO and MDP radiopharmaceutical kits

    International Nuclear Information System (INIS)

    Sebastian, Maria V.A.; Lugon, Marcelo Di M.V.; Silva, Jose L. da; Fukumori, Neuza T.O.; Pereira, Nilda P.S. de; Silva, Constancia P.G. da; Matsuda, Margareth M.N.

    2007-01-01

    A sensitive, alternative method to atom absorption spectrometry, fluorimetry or potentiometry for the evaluation of tin(II) ions (0.1- 10 mg) and total tin in radiopharmaceutical kits was investigated. Differential pulse polarography was chosen. The supporting electrolyte was H 2 SO 4 3 mol L -1 and HCl 3 mol L -1 solution. The potential was swept from -250 to -800 mV vs Ag/AgCl/saturated KCl, using a dropping mercury electrode with 1 s drop time, 50 mV s -1 scan rate, -50 mV pulse amplitude, 40 ms pulse time and 10 mV step amplitude. Pure nitrogen was used to deaerate the polarographic cell solution for 5 min, before and after each sample introduction. Oxidation of Sn(II) was made in the same sample vial by adding H 2 O 2 (hydrogen peroxide) 10 mol L -1 , at 37 deg C, in order to quantify the total Sn. The calibration curve for Sn(II) and Sn(IV) was obtained in the concentration range of 0-10 ppm from a 1000 ppm standard solution. The detection limit of Sn(II) is 0.5 ppm and for Sn(IV) is 0.6 ppm. Differential pulse polarography was performed in the pyrophosphate (PYRO) and methylenediphosphonic acid (MDP) radiopharmaceutical kits, containing 2 mg and 1 mg of SnCl 2 .2H 2 O per vial, respectively. The described method for determination of stannous ion (Sn(II)), is selective, reproducible and adequate to be used in the quality control of lyophilized reagents and it shall be performed for other cold kits produced at IPEN. (author)

  15. Polarographic determination of the titanium and niobium content of zirconium alloys

    International Nuclear Information System (INIS)

    Levin, R; Gabra, J.

    1978-03-01

    A method is described for the polarographic determination of titanium and niobium in zirconium alloys in the concentration range of 0.1% to 4% of each of the determined metals. To assure the complete dissolution of the sample a mixture of nitric acid and hydrofluoric acid is used. After evaporating these acids in the presence of sulphuric acid, the contents are determined polarographically with a supporting electrolyte solution of 0.1M EDTA, 0.33M potassium sulfate and 0.4M sodium acetate, buffered to pH 4 with acetic acid. The half-wave potential (Esub(1/2)) of titanium is -0.35V and that of niobium is -0.67 V. (author)

  16. Polarographic determination of Iodide and Iodate, in Solutions Coming from Aerosols in Fission Products Containment Studies in Nuclear Power Stations

    International Nuclear Information System (INIS)

    Sanchez, M.; Ballesteros, O.; Fernandez, M.; Clavero, M.A.; Gonzalez, A.M.

    2000-01-01

    A polarographic method is described for the iodine species determination, iodide and iodate in water solutions. the iodate can be determined by differential pulse polarography. Calibration curves and the detection and determination limits have been obtained. Iodides is oxidized to iodate with sodium hypochlorite and the excess of oxidizing agent is destroyed with sodium sulphide. The concentration of iodide is calculated as the difference between the concentration of iodate in the sample before and after the oxidation. As an application, species of iodine in samples coming from the experimental plants GIRS (Gaseous Iodine Removal by Sprays) of Nuclear Fission Department of the CIEMAT, dedicated to fission products containment studies in nuclear power station, were determined. (Author) 10 refs

  17. Analysis of molybdenum, chromium, vanadium and iron by polarographic techniques

    International Nuclear Information System (INIS)

    Al-Zand, T.K.

    1986-01-01

    The application of direct current Tast polarograph, differential pulse polarography and phase-selective alternative current Tast polarography to the problem of determining molybdenum, chromium, vanadium and iron in various supporting electrolytes is reported. The effect of the supporting electrolyte on the wave/peak potential and sensitivity of the metal ion have been examined. The polarographic methods were applied for simultaneous determination of chromium (3)/chromium (6), vanadium (4), vanadium (5) and iron (2)/iron (3) in different supporting electrolytes

  18. Polarographic behaviour and determination of selenite and tellurite in simple solutions or in a binary mixture

    International Nuclear Information System (INIS)

    Hassan, A.

    1991-01-01

    The polarographic behaviour of simple solutions of selenite and tellurite in 1 M ammonium salts of formate, acetate, tartrate, oxalate, and benzoate solutions in absence and in presence of Triton X-100 as a maximum suppressor and a temperature of 25 O C has been investigated. Schemes for the mechanism of reductions occuring at the DME have been deduced. A method for analytical determination of selenite and tellurite in simple solutions as well as in a binary mixture in the presence of 4-14 . 10 -3 % Triton X-100 is reported. (author)

  19. Polarographic determination of stability constants of Eu(III) complexes with acrylic acid and crotonic acid

    Energy Technology Data Exchange (ETDEWEB)

    Rao, A L.J.; Makhan, S [Punjabi Univ., Patiala (India). Dept. of Chemistry

    1979-07-01

    Compositions and formation constants of Eu(III) complexes with acrylic acid and crotonic acid have been studied polarographically. The reductions are reversible and diffusion-controlled. The plot of Esub(1/2) versus -log Csub(x) is linear in the case of Eu(III)-acrylic acid system. The change in number of ligands bound to europium during reduction was found to be approximately equal to 1 and ratio of dissociation constants of Eu(III) and Eu(II) was found to be 40.76 x 10sup(-2). In the case of Eu(III)-crotonic acid system, composition and formation constants have been calculated by the method of Deford and Hume. Crotonic acid forms two complex species with europium (..beta../sub 1/, 60; ..beta../sub 2/, 4.2x10sup(+2)). The percentage distribution of various complex species as a function of ligand concentration has been calculated in the case of Eu(III)-crotonic acid system. A polarographic method for the determination of micro amounts of Eu(III) in the presence of diverse ions has been developed. Under optimum conditions Eu(III) in the concentration range 4x10sup(-4)-2x10sup(-3)M can be successfully determined in various mixtures.

  20. Polarographic determination of stability constants of Eu(III) complexes with acrylic and crotonic acid

    Energy Technology Data Exchange (ETDEWEB)

    Rao, A L.J.; Singh, Makhan [Punjabi Univ., Patiala (India). Dept. of Chemistry

    1979-07-01

    Compositions and formation constants of Eu(III) complexes with acrylic acid and crotonic acid have been studied polarographically. The reductions are reversible and diffusion-controlled. The plot of Esub(1/2) versus--log Csub(x) is linear in the case of Eu(III)-acrylic acid system. The change in number of ligands bound to europium during reduction was found to be approximately 1 and ratio of dissociation constants of Eu(III) and Eu(II) was found to be 40.76X10sup(-2). In the case of Eu(III)-crotonic acid system, composition and formation constants have been calculated by the method of Deford and Hume. Crotonic acid forms two complex species with europium (..beta../sub 1/,60; ..beta../sub 2/, 4.2x10sup(+2)). The percentage distribution of various complex species as a function of ligand concentration has been calculated in the case of Eu(III)-crotonic acid system. A polarographic method for the determination of micro amounts of Eu(III) in the presence of diverse ions has been developed. Under optimum conditions Eu(III) in the concentration range 4x19sup(-4)-2x10sup(-2)M can be successfully determined in various mixtures.

  1. Polarographic determination of selenium and tellurium in silver-gold alloys

    International Nuclear Information System (INIS)

    Gornostaeva, T.D.; Shmargun, S.V.

    1986-01-01

    The determination of selenium and tellurium is of importance in monitoring the composition of silver-gold alloys (SGA) since these elements are harmful impurities in the pure metals. Tellurium is determined in silver alloys by atomic absorption and atomic emmission methods; selenium determination is made by atomic absorption methods. This paper examines the polarographic determination of silver and tellurium in SGA containing platinum metals and copper. Copper and the bulk of the platinum and palladium were removed by precipitating selenium and tellurium with potassium hypophosphite in the elementary state from 6 M HC1. The results of an analysis of samples of SGA according to the proposed method were compared with the results obtained by the atomic absorption method. the relative deviation in the determination of 0.02-1.0% by weight selenium and tellurium does not exceed 0.12 (n = 5)

  2. Linear sweep polarographic determination of nucleic acids using acridine orange as a bioprobe

    Directory of Open Access Journals (Sweden)

    WEI SUN

    2007-11-01

    Full Text Available The interaction of acridine orange (AO with double-stranded (ds DNA in aqueous solution was investigated by linear sweep polarography (LSP on a dropping mercury working electrode (DME. In pH 2.5 Britton–Robinson (B–R buffer solution, AO had a sensitive linear sweep polarographic reductive peak at –0.89 V (vs. SCE, which could be greatly inhibited by the addition of dsDNA, with a positive shift of the peak potential. Based on the decrease of the reductive peak current, a new quantitative electrochemical determination method for dsDNA was developed with a linear range of 2.0−20.0 mg l-1 and the linear regression equation: ΔIp” (nA = 111.90 C (mg l-1+125.32 (n = 9, γ = 0.997. The influences of commonly co-existing substances, such as metal ions, amino acid, etc., on the determination were also investigated. The method is sensitive, rapid and simple with good selectivity. The new proposed method was further applied to the detection of RNA and three synthetic samples containing dsDNA with satisfactory results. The binding number and the equilibrium constant between dsDNA and AO were calculated by an electrochemical method.

  3. Determination of Sn in 99mTc Radiopharmaceutical Kits by Polarographic Methods

    International Nuclear Information System (INIS)

    Castro, M.; Cruz, J.; Sanchez, M.

    2009-01-01

    Kits of 99 m Tc radiopharmaceuticals are used in nuclear medicine for diagnosis of different diseases. Sn (II) is one of the essential components in their formulations, which is used for reduction 99 m Tc-pertechnetate in cold kits for on-site preparation 99 m Tc-pertechnetate radiopharmaceuticals. Usually, these cold kits contain different additives (complexing agents, antioxidants, buffers, etc.) and the amount of Sn (II) varies from kit to kit. The determination of Sn in these products is essential in assessing their quality. We report here the development of a new polarographic method for the determination of Sn (II) and total Sn in representative radiopharmaceuticals kits (for the content of Sn and chemical composition) produced at the Center of Isotopes of Cuba (CENTIS). These methods were validated by analysis of variance and recovery techniques. From the results of the validation, the characteristic functions of uncertainties and fits are considered for the established methods, which give the necessary evidences to demonstrate the usefulness of these methods according to the current trends in Analytical Chemistry. This work provides practical results of great importance for CENTIS. After the speciation of Sn in the MAG3 radiopharmaceuticals kit is inferred that the production process is affected by uncontrolled factors that influence in the product stability, which demonstrates the necessity for analytical tools for the characterization of products and processes. (Author) 57 refs.

  4. The contents of sesamol and related lignans in sesame, tahina and halva as determined by a newly developed polarographic and stripping voltammetric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Tokusoglu, O.; Kocak, S.; Aycan, S.

    2009-07-01

    The contents of antioxidant lignans (Sesamol) in sesame, commercial formulations of tahina and halva, which are processed tahina foods, were determined by Differential Pulse Polarography (DPP) with a capillary hanging mercury drop electrode (HMDE). A platinum wire was used as the counter electrode and Ag/AgCl was the reference electrode. Samples have been analyzed by standard addition procedures and found to be quantitative (p<0.01). Due to the fact that sesamol is an oil-soluble phenolic compound , it was found in the oil levels of sesame, tahina and halvas. Sesame samples contained 51.05-56.46 % in oil whereas tahina samples contained 52.12-53.79 % in oil. The oil percentage of plain halva was found to be 28.79 - 30.13 % (p<0.01). Phenolic lignans sesamol in sesame was 0.26-0.32 mg/100g oil, whereas the sesamol in tahina was 10.98-12.33 mg/100g oil. The sesamol in commercial plain halva samples and the open marketed plain halva samples contained 8.24-9.12 mg/100g oil and 4.97 mg sesamol /100g oil, respectively (R{sup 2}=0.9999) (p<0.01). The proposed Differential Pulse Polarographic (DPP) method is a rapid, reproducible procedure for the simultaneous determination of phenolic lignans in sesame and food products with sesame. It provides an adequate, sensitive, quantitative detection of these nutraceuticals in the commercial food industry. (Author) 26 refs.

  5. Copper separation using modified active carbon before the polarographic determination of Pb, Cd, Ni, Zn and Fe in wastes

    International Nuclear Information System (INIS)

    Rubel, S.; Lada, Z.M.; Golimowski, J.

    1977-01-01

    The investigations on the selective separation of Pb 2+ , Cd 2+ , Ni 2+ , Zn 2+ and Fe 3+ ions from the excess of copper were carried out. For this purpose active carbon modified by Na-diethyldithiocarbamate was used. The manner of DDTK-Na deposition on active carbon has been elaborated. The influence of pH was investigated and it was found that at pH 1(HNO 3 ) copper ions are quantitavely bound on modified carbon whereas other ions (Pb 2+ , Cd 2+ , Ni 2+ , Zn 2+ and Fe 3+ ) remain in the solution and can be determined polarographically. The elaborated method was applied to the determination of mentioned ions in the samples of wastes containing even 100-fold excess of copper. The concentration of copper can not exceed 100 mg/dm 3 . (author)

  6. Polarographic behaviour and determination of uranium(VI) in alcoholic solutions from organic extraction phases

    International Nuclear Information System (INIS)

    Degueldre, C.; Taibi, K.

    1996-01-01

    The determination of U(VI) in organic extraction phases: hydrocarbon-diethyl-2-hexyl phosphoric acid-trioctylphosphine oxide and hydrocarbon-tri-n-octylamine, diluted by an alcohol has been studied by direct current polarography, as well as by differential pulse polarography (DPP). In order to optimise the analytical procedure, miscibility and conductivity studies of the mixtures hydrocarbon-alcohol (ethanol, n- and isopropanol and n- and isobutanol) were made after addition of sulphuric acid as a supporting electrolyte. In the solutions of sulphuric acid in the alcohol-extractant-hydrocarbon phases, U(VI) gives rise to well defined polarograms. Its electroreduction involves a single electron step in all cases. The DPP peak height is proportional to the U(VI) concentration between 2x10 -6 and 2x10 -3 M, and the 3σ detection limit is ca. 10 -6 M

  7. DC Polarographic and Plane Polarographic investigation of the ...

    African Journals Online (AJOL)

    Bheema

    D.C., A.C. and Complex Plane Polarographic behavior of copper (II) in monoethanolamine /sodium ... The Cd of supporting electrolyte can be directly measured. Theoretical phase sensitive ..... The mass and drop time of mercury are provided ...

  8. Polarographic determination of uranium dioxide stoichiometry; La determination polarographique de la stoechiometrie du dioxyde d'uranium

    Energy Technology Data Exchange (ETDEWEB)

    Viguie, J.; Uny, G. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Grenoble, 38 (France)

    1966-10-01

    The method described allows the determination of small deviations from stoichiometry for uranium dioxide. It was applied to the study of surface oxidation of bulk samples. The sample is dissolved in phosphoric acid under an argon atmosphere; U(VI) is determined by polarography in PO{sub 4}H{sub 3} 4.5 N - H{sub 2}SO{sub 4} 4 N. U(IV) is determined by potentiometry. The detection limit is UO{sub 2,0002}. The accuracy for a single determination at the 95% confidence level is {+-}20 per cent for samples with composition included between UO{sub 2,001} and UO{sub 2,01}. (authors) [French] La methode decrite permet de determiner les faibles ecarts a la stoechiometrie du dioxyde d'uranium. Elle a ete appliquee a l'etude de l'oxydation superficielle des echantillons. La mise en solution s'effectue dans l'acide phosphorique concentre sous atmosphere d'argon; U(VI) est dose par polarographie dans le milieu PO{sub 4}H{sub 3} 4,5 N et H{sub 2}SO{sub 4} 4 N; U(IV) est dose par potentiometrie. La limite de detection est UO{sub 2,0002}. La precision obtenue pour une determination au taux de certitude 0,95 est de l'ordre de 20 pour cent pour des echantillons dont la teneur est comprise entre UO{sub 2,001} et UO{sub 2,01}. (auteurs)

  9. Determination of Sn in 99{sup m}Tc Radiopharmaceutical Kits by Polarographic Methods; Determinacion de Estano en Radiofarmacos de 99{sup m}Tc mediante Metodos Polarograficos

    Energy Technology Data Exchange (ETDEWEB)

    Castro, M; Cruz, J; Sanchez, M

    2009-07-01

    Kits of 99{sup m}Tc radiopharmaceuticals are used in nuclear medicine for diagnosis of different diseases. Sn (II) is one of the essential components in their formulations, which is used for reduction 99{sup m}Tc-pertechnetate in cold kits for on-site preparation 99{sup m}Tc-pertechnetate radiopharmaceuticals. Usually, these cold kits contain different additives (complexing agents, antioxidants, buffers, etc.) and the amount of Sn (II) varies from kit to kit. The determination of Sn in these products is essential in assessing their quality. We report here the development of a new polarographic method for the determination of Sn (II) and total Sn in representative radiopharmaceuticals kits (for the content of Sn and chemical composition) produced at the Center of Isotopes of Cuba (CENTIS). These methods were validated by analysis of variance and recovery techniques. From the results of the validation, the characteristic functions of uncertainties and fits are considered for the established methods, which give the necessary evidences to demonstrate the usefulness of these methods according to the current trends in Analytical Chemistry. This work provides practical results of great importance for CENTIS. After the speciation of Sn in the MAG3 radiopharmaceuticals kit is inferred that the production process is affected by uncontrolled factors that influence in the product stability, which demonstrates the necessity for analytical tools for the characterization of products and processes. (Author) 57 refs.

  10. Polarographic determination of Iodide and Iodate, in Solutions Coming from Aerosols in Fission Products Containment Studies in Nuclear Power Stations; Determinacion Polarografica de Especies de Iodo (Ioduro y Iodato) en Soluciones Procedentes de Aerosoles, para Estudios de Contencion de Productos de Fision en Centrales Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, M.; Ballesteros, O.; Fernandez, M.; Clavero, M.; Gonzalez, A. M. [Ciemat, Madrid (Spain)

    2000-07-01

    A polarographic method is described for the iodine species determination, iodide and iodate in water solutions. the iodate can be determined by differential pulse polarography. Calibration curves and the detection and determination limits have been obtained. Iodides is oxidized to iodate with sodium hypochlorite and the excess of oxidizing agent is destroyed with sodium sulphide. The concentration of iodide is calculated as the difference between the concentration of iodate in the sample before and after the oxidation. As an application, species of iodine in samples coming from the experimental plants GIRS (Gaseous Iodine Removal by Sprays) of Nuclear Fission Department of the CIEMAT, dedicated to fission products containment studies in nuclear power station, were determined. (Author) 10 refs.

  11. Catalytic polarographic currents of platinum metal complexes and their application to determination of trace concentrations of the elements

    International Nuclear Information System (INIS)

    Ezerskaya, N.A.; Kiseleva, I.N.

    1984-01-01

    Several types of catalytic electrode processes with the participation of platinum metal complexes and used for the determination of the element microconcentrations have been considered in the review. It is pointed out that to measure catalytic currents of hydrogen solutions nitroso compounds, which are prepared by heating chloride complexes of Ru(3) and (4) with NaNO 2 are used. The method is applicable for ruthenium determination in commercial nitric acid solutions. Ru determination in solution of ruthenium (4) dimeric chloride complex on graphite electrode, using catalytic currents of hydrogen, surpasses in sensitivity the determination of the element, using the method of inversion voltammetry. Certain other complexes of Ru and determination methods of ruthenium in them are considered. Hydrogen catalytic currents in the complexes solutions with organic ligands are the most perspective for analysis

  12. Vanadium determination in raw materials and products of aluminium production using pulse polarography

    International Nuclear Information System (INIS)

    Grigor'eva, M.F.; Bal'de, I.; Markovich, I.A.

    1992-01-01

    Possibility of using differential pulse polarography (DPP) for determination of vanadium in raw materials and products of aluminium production was studied. Ammonium-cheoride buffer solution with pH 9-10, aqueous solution of mixture of sodium carbonate and borax (1:3) and rhodanide-acefic acid solutions (1:1) were tested as a background. Current-voltage curves of vanadium reduction were plotted and peak potentials on DPP were determined against the background of chosen electrolytes. Effect of parameters, providing the maximal height of DPP peak, on the height of measured signal, was studied. Rhodanide background was chosen for polarographic determination of vanadium, because the detection limit of vanadium was the lowest against this background. Pulse polarography enafles to determine vanadium in products of aluminium production in amounts from 1x10 -4 to 0.01 % and more

  13. Determination of microamounts of neptunium by differential pulse polarography

    International Nuclear Information System (INIS)

    Cauchetier, Ph.

    1979-01-01

    Neptunium is produced in significant amounts in the ''light-water'' reactors and must be controlled at different steps of fuel reprocessing. For this purpose a method of differential pulse polarography has been developed. A tight cell containing 10 ml solution is set up in a Faraday cage. Adjustment to the tetravalent state, Np(IV), is carried out electrochemically on a mercury layer and the Np(IV) concentration is determined by differential pulse polarography, using a dropping mercury electrode. In 0.5M sulfuric acid medium, the redox potential of the reversible couple Np(IV)/Np(III) is -0.3 V/SCE. Concentrations as low as 5x10 -7 M neptunium can be measured and detection at the 2x10 -7 M level is still possible (0.5 μg in the polarographic cell). Precision is about 2% in the 10 -5 M and 10% in the 10 -6 M range. The method has been applied to aqueous and organic (TBP-dodecane) solutions. Neptunium can be determined without separation in the presence of plutonium or uranium at M/Np ratios of 10 3 and 5x10 4 , respectively. In the presence of fission products a separation is needed. (author)

  14. Determination of microamounts of neptunium by differential pulse polarography

    International Nuclear Information System (INIS)

    Cauchetier, P.

    1978-01-01

    Neptunium is produced in significant amounts in the light water reactors and must be controlled at different steps of the fuel reprocessing. For this purpose, a method of differential pulse polarography was developed. A tight cell containing 10 ml of solution is set up in a Faraday's cage. Adjustment to the tetravalent state, Np (IV), is carried out electrochemically on a mercury layer and the Np (IV) concentration is determined by differential pulse polarography, using a dropping mercury electrode. In 0,5 M sulfuric acid medium, the redox potential of the reversible system Np (IV)/Np (III) is - 0,3 V/SCE. Concentrations as low as 5.10 -7 M of neptunium can be measured and detection at the 2.10 -7 M level is still possible (0,5 μg in the polarographic cell). Precision is about 2% in the 10 -5 M and 10% in 10 -6 M range. The method has been applied to the case of aqueous and organic (TBP dodecane) solutions. Neptunium can be determined without separation in the presence of plutonium or uranium in the M/Np ratios of 10 3 and 5.10 4 respectively. In the presence of fission products a separation is needed

  15. Polarographic, spectrophotometric and coulometric studies of MoO=4 in H2SO4

    International Nuclear Information System (INIS)

    Tokoro, R.; Bertotti, M.

    1990-01-01

    This study characterizes the polarographic process of Mo O sup(=) sub(4) in H sub(2)SO sub(4) medium, determining which species is responsible by catalytic cycle. Spectrophotometric and coulometric studies are also described. (author)

  16. Polarographic studies on the nature of cadmium in scallop, oyster, and lobster

    Energy Technology Data Exchange (ETDEWEB)

    Chou, C L; Uthe, J F; Zook, E G

    1978-04-01

    Free and bound forms of cadmium were determined in raw shellfish by use of differential pulse polarography and atomic absorption spectrophotometry. Free cadmium is defined by its polarographic peak potential of -0.62 +- 0.02 V (saturated calomel electrode) in solvent washed ammonium sulfate extracts. Bound cadmium was determined by subtracting the free cadmium from the total cadmium present in the meat. Both scallop (various species) and American lobster (Homarus americanus) muscle tissues contain no free cadmium. Oyster (various species), on the other hand, had a considerable percentage (approximately 50%) of its total cadmium present as free cadmium, a phenomena as yet unexplained. The detection limit for free cadmium is approximately 0.05 ..mu..g/g raw tissue.

  17. Determination of uranium in plutonium--238 metal and oxide by differential pulse polarography

    International Nuclear Information System (INIS)

    Fawcett, N.C.

    1976-01-01

    A differential pulse polarographic method was developed for the determination of total uranium in 238 Pu metal and oxides. A supporting electrolyte of 0.5 M ascorbic acid in 0.15 N H 2 SO 4 was found satisfactory for the determination of 500 ppM or more of uranium in 10 mg or less of plutonium. A relative standard deviation of 0.27 to 4.3 percent was obtained in the analysis of samples ranging in uranium content from 0.65 to 2.79 percent. The limit of detection was 0.18 μg ml -1 . Peak current was a linear function of uranium concentration up to at least 100 μg ml -1 . Amounts of neptunium equal to the uranium content were tolerated. The possible interference of a number of other cations and anions were investigated

  18. The contents of sesamol and related lignans in sesame, tahina and halva as determined by a newly developed polarographic and stripping voltammetric analysis

    Directory of Open Access Journals (Sweden)

    2009-06-01

    Full Text Available The contents of antioxidant lignans (Sesamol in sesame, commercial formulations of tahina and halva, which are processed tahina foods, were determined by Differential Pulse Polarography (DPP with a capillary hanging mercury drop electrode (HMDE. A platinum wire was used as the counter electrode and Ag/AgCl was the reference electrode. Samples have been analyzed by standard addition procedures and found to be quantitative (p2=0.9999 (pSe determinó el contenido del lignano antioxidante (Sesamol en sésamo, formulaciones comerciales de tahina y halva, que es el producto procesado de tahina, por polarografía de pulsos diferencial (DPP con un capilar conteniendo un electrodo de gota de mercurio (HMDE. Un hilo de platino fué usado como el electrodo contador y Ag/AgCl como electrodo de referencia. Las muestras fueron analizadas por procedimientos de adición de patrones y se encontró que wl procedimiento era cuantitativo (p2= 0.9999 (p< 0.01. El método polarográfico propuesto (DPP es un método rápido y reproducible para la determinación simultánea de lignanos fenólicos en sésamo y otros productos alimentarios que contienen sésamo. Éste proporciona una detección cuantitativa adecuada y sensible de este compuesto nutraceútico en alimentos comerciales.

  19. Assay of Aliphatic Phthalates in Polymer Products by Sensitive Polarographic Method: Health and Environmental Issue

    Directory of Open Access Journals (Sweden)

    Munawar Saeed

    2010-06-01

    Full Text Available A faster, simpler and sensitive method was developed for determination of aliphatic phthalates using differential pulse polarography (DPP as standard technique. The choice and concentration of base electrolyte, solvent, initial potential, effect of water addition and interference by other phthalates were the main parameters to optimize for enhancement of peak current and to obtain well-defined polarogram with lower background current using 1.3 x 10-4 M di-butyl phthalate (DBP solution. Best results were obtained in the presence of tetra methyl ammonium bromide (TMAB as electrolyte in methanol solvent with initial potential, -1.4 V. A linear calibration plot was observed in the range of 3 x 10-7 – 1.6 x 10-4 M DBP solution as aliphatic phthalates with lower detection limit of 5.9 x 10-8 M and linear regression coefficient of 0.9987. The developed polarographic method was successfully applied for analysis of aliphtaic phthalates in various samples of locally available polymer products such as baby toys, nipples, teethers, infusion blood bags and shopping bags. The results of the current method were compared with those obtained by a reported method and good agreement was found between them.

  20. Oxygen tension and prediction of the radiation response. Polarographic study in human breast cancer

    International Nuclear Information System (INIS)

    Pappova, N.; Siracka, E.

    1982-01-01

    Serial polarographic measurement of the tissue oxygen tension (pO 2 ) was made in the course of fractionated irradiation (preoperative or sole treatment) of advanced breast cancer in 24 patients. In responsive tumors an increase in pO 2 appeared sooner before expressive tumor size reduction became noticeable. Repeated recording of unchanged pO 2 values proved to be a good prognostic indicator of local failure. The study made on this tumor model showed that serial polarographic pO 2 determinations with suitable electrodes causing minimal trauma and providing consistent and reproductive data about changes in tumor microcirculation and oxygenation may enlarge the scale of indicators of radiation response. (author)

  1. Polarographic reduction of Yb/sup +3/ benzoate and salicylate complexes in aqueous-nonaqueous mixtures at D. M. E

    Energy Technology Data Exchange (ETDEWEB)

    Zutshi, K; Gupta, K C [Rajasthan Univ., Jaipur (India). Dept. of Chemistry

    1977-01-01

    The reduction of Yb/sup +3/ and Yb/sup +3/-benzoate and salicylate complexes was studied polarographically at constant ionic strength at 25 +- 0.02/sup 0/C in aqueous-nonaqueous mixtures. The reduction was found to be diffusion-controlled, but the electrode process was irreversible in all cases. The kinetic parameters were determined by Koutecky's method.

  2. Iodine sorption of bentonite - radiometric and polarographic study

    International Nuclear Information System (INIS)

    Konirova, R.; Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    The experiments focused on kinetics of iodine retardation on bentonite, influence of aqueous phase pH, buffering properties of bentonite, etc. were carried out by batch method. Distribution coefficient KD was the criterion applied for evaluation of iodine interaction with solid phase. High sorption potential of bentonite to cationic forms of various radionuclides, resulting from relatively high cation exchange capacity, is generally known. On the other hand the inorganic anions are not adsorbed strongly to mineral surface of clays thus uptake of iodine (occurring mainly at iodide (I - ) or iodate (IO 3 - ) form under oxoic conditions) is limited. The distribution coefficients of iodine anions' sorption on bentonite R reach order of magnitude 10 -1 mL/g. In order to increase the sorption capacity of the solid phase, several additives were added to bentonite. Most of them didn't provide satisfactory results except of the addition of activated carbon, which has high surface area. Electromigration and polarographic methods were used for investigation of the redox state of iodine in aqueous phase and determination of KD values as well. Acquired results were compared with data obtained by radiometric measurements. (authors)

  3. Direct determination of the hit locations from experimental HPGe pulses

    Energy Technology Data Exchange (ETDEWEB)

    Désesquelles, P., E-mail: Pierre.Desesquelles@in2p3.fr [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dimmock, M.R. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Ljungvall, J. [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Nelson, L. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nga, D.-T. [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Nolan, P.J.; Rigby, S.V. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Van-Oanh, N.-T. [Univ. Paris-Sud, LCP UMR8000 CNRS, 15 rue G. Clémenceau, 91405 Orsay (France)

    2013-11-21

    The gamma-tracking technique optimises the determination of the energy and emission angle of gamma-rays detected by modern segmented HPGe detectors. This entails the determination, using the delivered pulse shapes, of the interaction points of the gamma-ray within the crystal. The direct method presented here allows the localisation of the hits using only a large sample of pulses detected in the actual operating conditions. No external crystal scanning system or pulse shape simulation code is needed. In order to validate this method, it is applied to sets of pulses obtained using the University of Liverpool scanning system. The hit locations are determined by the method with good precision.

  4. Pulse to pulse beam trajectory determination at the IP

    International Nuclear Information System (INIS)

    Koska, W.; Wagner, S.

    1988-01-01

    It has long been known that a precise measurement of the SLC beam trajectory through the IP region is vital both from a machine and a detector point of view. One of the primary techniques used to maximize luminosity is the measurement of the deflection angle of one beam produced by the electromagnetic interaction with the other beam. In order to implement this procedure a pair of precision Beam Position Monitors (BPMs) were installed within the Final Triplet of quadrapoles on each side of the IP. Before the IP BPMs could be used to measure beam-beam deflection, a series of measurements were made of the coefficients which relate the setting of an orbit correction magnet to the position of the beam at a particular BPM (R 12 s). The purpose was to expose any problems such as misconnected cables, etc., by comparing the measured R 12 s with theoretical predictions from the model of the Final Focus region. A technique developed that uses position measurements in the long BPMs to determine a three parameter fit to the beam trajectory at the IP. The three parameters in the fit are the beam position, the incoming angle and the deflection angle. The result was very successful and allows the observation of beam-beam deflection even under marginal conditions. The purpose of this memo is to clear up the technical points and to demonstrate that the simplicity of the fit should allow the implementation of this procedure at the micro level, where it could provide trajectory information in real time which would go a long way toward making it useful as a fast feedback tool and in addition allow easy real time access to beam position data by the Mark II

  5. Polarographic measurement of ascorbate washout in isolated perfused rabbit hearts

    International Nuclear Information System (INIS)

    Arts, T.; Kuikka, J.T.; Reneman, R.S.; Bassingthwaighte, J.B.

    1985-01-01

    To study the myocardial washout of ascorbate, the applicability of polarographic detection of ascorbate ions by a platinum electrode (sensitive area 0.03 mm2) was investigated, in both a calibration setup (sampling flow along the electrode: 100 microliter X s-1) and isolated, retrogradely perfused rabbit hearts. In the calibration setup at pH 7.4, the sensitivity of the electrode was 70 microA/mol. This sensitivity increased moderately with increasing pH (13%/unit pH) and increasing sampling flow rate (14% at an increase from 100 to 150 microliter X s-1). In the isolated hearts, ascorbate infused into the aorta was detected in a right ventricular drain by the electrode as well as by the use of 14 C-labeled ascorbate. Both recorded time courses were similar except for a scaling factor dependent on flow velocity. During continuous infusion the arteriovenous difference of ascorbate was 2 +/- 2% (SD), indicating a relatively low consumption of ascorbate by the isolated heart. The authors conclude that polarographic measurement of ascorbate in the coronary effluent of an isolated rabbit heart can be performed on-line and relatively easily

  6. Polarographic validation of chemical speciation models

    International Nuclear Information System (INIS)

    Duffield, J.R.; Jarratt, J.A.

    2001-01-01

    It is well established that the chemical speciation of an element in a given matrix, or system of matrices, is of fundamental importance in controlling the transport behaviour of the element. Therefore, to accurately understand and predict the transport of elements and compounds in the environment it is a requirement that both the identities and concentrations of trace element physico-chemical forms can be ascertained. These twin requirements present the analytical scientist with considerable challenges given the labile equilibria, the range of time scales (from nanoseconds to years) and the range of concentrations (ultra-trace to macro) that may be involved. As a result of this analytical variability, chemical equilibrium modelling has become recognised as an important predictive tool in chemical speciation analysis. However, this technique requires firm underpinning by the use of complementary experimental techniques for the validation of the predictions made. The work reported here has been undertaken with the primary aim of investigating possible methodologies that can be used for the validation of chemical speciation models. However, in approaching this aim, direct chemical speciation analyses have been made in their own right. Results will be reported and analysed for the iron(II)/iron(III)-citrate proton system (pH 2 to 10; total [Fe] = 3 mmol dm -3 ; total [citrate 3- ] 10 mmol dm -3 ) in which equilibrium constants have been determined using glass electrode potentiometry, speciation is predicted using the PHREEQE computer code, and validation of predictions is achieved by determination of iron complexation and redox state with associated concentrations. (authors)

  7. Variation of pHS value of mercury-dropping electrode layer in the process of molecular oxygen electro-reduction in polarographic determination of indium(3), cadmium(2), and thallium(1)

    International Nuclear Information System (INIS)

    Statsyuk, V.N.; Dergacheva, M.B.

    1998-01-01

    Quantitative evaluation of the pH S variation of an electrode layer in the process of molecular oxygen electroreduction in the indium(3), cadmium(2) and thallium(1) solutions by means of gallium introduction is carried out. the accomplished studied showed the possibility for determination of small amounts 10 -5 -10 -4 mole/l of indium at the background of the gallium concentrated solutions without removal of dissolved oxygen

  8. The potential for biological structure determination with pulsed neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, C.C. [CLRC Rutherford Appleton Laboratory, Chilton Didcot Oxon (United Kingdom)

    1994-12-31

    The potential of pulsed neutron diffraction in structural determination of biological materials is discussed. The problems and potential solutions in this area are outlined, with reference to both current and future sources and instrumentation. The importance of developing instrumentation on pulsed sources in emphasized, with reference to the likelihood of future expansion in this area. The possibilities and limitations of single crystal, fiber and powder diffraction in this area are assessed.

  9. The potential for biological structure determination with pulsed neutrons

    International Nuclear Information System (INIS)

    Wilson, C.C.

    1994-01-01

    The potential of pulsed neutron diffraction in structural determination of biological materials is discussed. The problems and potential solutions in this area are outlined, with reference to both current and future sources and instrumentation. The importance of developing instrumentation on pulsed sources in emphasized, with reference to the likelihood of future expansion in this area. The possibilities and limitations of single crystal, fiber and powder diffraction in this area are assessed

  10. Oxygen tension in human tumours measured with polarographic needle electrodes and its relationship to vascular density, necrosis and hypoxia

    International Nuclear Information System (INIS)

    Lyng, Heidi; Sundfoer, Kolbein; Rofstad, Einar K.

    1997-01-01

    Background and purpose: The use of polarographic needle electrodes for measurement of oxygen tension (pO 2 ) in tumours requires documentation of the validity of the method. In the present work the pO 2 values measured polarographically with the Eppendorf pO 2 histograph in human tumours were compared with the histological appearance of the tumour tissue, i.e. vascular density, fraction of necrosis and fraction of hypoxic tissue, to investigate whether the measurements reflected the expected pO 2 . Materials and methods: The pO 2 was measured in cervix tumours in patients and in human melanoma xenografted tumours in athymic mice. Vascular density was determined in the cervix tumours by histological analysis of biopsies from the pO 2 measurement tracks. Fraction of necrosis and fraction of hypoxic tissue, i.e. tissue binding the hypoxia marker pimonidazole, were determined in the melanomas by analysis of histological sections from the tumour planes in which the pO 2 measurements were performed. Results: The pO 2 distributions showed large intratumour heterogeneity. In cervix tumours, tumour regions with vascular density (vascular length per unit tissue volume) in the range of 47-77 mm/mm 3 showed higher pO 2 than tumour regions with vascular density in the range of 20-47 mm/mm 3 , which in turn showed higher pO 2 than tumour regions with vascular density in the range of 0-20 mm/mm 3 . In melanomas, tumour regions in which necrosis and hypoxia constituted more than 50% of the tissue showed lower pO 2 than other tumour regions. Conclusions: The pO 2 measured in the tumours was consistent with the histological appearance of the tissue in which the measurements were performed, suggesting that reliable pO 2 distributions of tumours can be obtained with polarographic needle electrodes

  11. Polarographic methods for the analysis of beryllium metal and its alloys

    International Nuclear Information System (INIS)

    Wells, J.M.

    1975-10-01

    This report describes polarographic methods for the analysis of beryllium metal and its alloys. The elements covered by these methods are aluminium, bismuth, cadmium, cobalt, copper, iron, lead, molybdenum, nickel, thallium, tungsten, uranium, vanadium and zinc. (author)

  12. Investigation of complexing equilibrium of polyacrylate-anion with cadmium ions by polarographic method

    Energy Technology Data Exchange (ETDEWEB)

    Avlyanov, Zh K; Kabanov, N M; Zezin, A B

    1985-01-01

    Polarographic investigation of cadmium complex with polyacrylate-anion in aqueous KCl solution is carried out. It is shown that the polarographic method allows one to define equilibrium constants of polymer metallic complex (PMC) formation even in the case when current magnitudes are defined by PMC dissociation reaction kinetic characteristics. The obtained equilibrium constants of stepped complexing provide the values of mean coordination PAAxCd complex number of approximately 1.5, that coincides with the value obtained by the potentiometric method.

  13. Investigation of complexing equilibrium of polyacrylate-anion with cadmium ions by polarographic method

    International Nuclear Information System (INIS)

    Avlyanov, Zh.K.; Kabanov, N.M.; Zezin, A.B.

    1985-01-01

    Polarographic investigation of cadmium complex with polyacrylate-anion in aqueous KCl solution is carried out. It is shown that the polarographic method allows one to define equilibrium constants of polymer metallic complex (PMC) formation even in the case, when current magnitudes are defined by PMC dissociation reaction kinetic characteristics. The obtained equilibrium constants of stepped complexing provide the values of mean coordination PAAxCd complex number of approximately 1.5, that coinsides with the value obtained by the potentiometric method

  14. The study of Cr3+/Cr2+ redox system by polarographic method

    Directory of Open Access Journals (Sweden)

    S. A. Pokhmyolkina

    2014-08-01

    Full Text Available Aim. The relevance of the theme is the ability to determine kinetic and thermodynamic parameters of the redox system on the example of Сr3/ Cr2in order to explain the reaction mechanism. In this paper, the electrochemical behavior of Cr+3/ Cr+2has been studied by polarography method. Polarogramshave been interpreted using the theory of irreversible polarographic waves and thermodynamically irreversible processes. Experiments have been carried out in a sealed cell with an outer casing for temperature control. Air oxygen removed from the feed solution for 15-20 minutes, purified nitrogen flowing from the cylinder. Characterization of the capillary in a 0.1N solution.H2SO4: mass flowing mercury m = 2,39 mg / sec; droplet formation period τ = 1,25 sec. Sulfate Cr (II was prepared by dissolving an electrolytic chromium 150 cm3 of water and 46 grams of 98 % sulphate acid. Thus a saturated solution formed a blue color. Sulfate salt solutions of two- and trivalent chromium in the medium of 0.1NH2SO4 give one wave. Anodic diffusion current sulfate Cr (II was 4,67μa, and half-wave potential E ½ = -0,44 V. The cathode current diffuse sulfate Cr (III, respectively - 7,65μa and E ½ = - 1,01 V. Inconsistency half-wave potentials of anodic and cathodic processes indicates its irreversibility. Half-wave potentials are given with respect to a saturated calomel electrode. Polarogramshave been investigated in the temperature range of 20-600C every 100C. Temperature coefficients have been calculated by the equation: Β% = idt –id20/ id20Δt, whereidtis diffusion current for a given concentration of the test solution at t0С; id20 is diffusion current for the same concentration at 200C; Δt - temperature change relative to 200C . Irreversibility, obviously due to the change in the electron configuration of chromium electrode is accompanying the redox process.Using the theory of irreversible polarographic waves we have determined the kinetic characteristics

  15. Determination of blood volume by pulse CO-oximetry

    International Nuclear Information System (INIS)

    Lalande, S; Kelsey, J W; Joyner, M J; Johnson, B D

    2012-01-01

    The objective of this study was to determine whether changes in carboxyhaemoglobin (COHb) saturation following carbon monoxide (CO) rebreathing can be accurately detected by pulse CO-oximetry in order to determine blood volume. Noninvasive measurements of carboxyhaemoglobin saturation (SpCO) were continuously monitored by pulse CO-oximetry before, during and following 2 min of CO rebreathing. Reproducibility and accuracy of noninvasive blood volume measurements were determined in 16 healthy non-smoking individuals (15 males, age: 28 ± 2 years, body mass index: 25.4 ± 0.6 kg m −2 ) through comparison with blood volume measurements calculated from invasive measurements of COHb saturation. The coefficient of variation for noninvasive blood volume measurements performed on separate days was 15.1% which decreases to 9.1% when measurements were performed on the same day. Changes in COHb saturation and SpCO following CO rebreathing were strongly correlated (r = 0.90, p < 0.01), resulting in a significant correlation between invasive and noninvasive blood volume measurements (r = 0.83, p = 0.02). Changes in SpCO following CO rebreathing can be accurately detected by pulse CO-oximetry, which could potentially provide a simplified, convenient and reproducible method to rapidly determine blood volume in healthy individuals

  16. The relationship between temporal variation of hypoxia, polarographic measurements and predictions of tumour response to radiation

    Science.gov (United States)

    Toma-Dasu, Iuliana; Dasu, Alexandru; Karlsson, Mikael

    2004-10-01

    to a systematic deviation between the actual oxygen distribution and the measured distribution. However, as the electrode reflects the general trends of the tissue oxygenation it has the potential of being used for the general characterization of tumour hypoxia even if the actual type of hypoxia measured by the electrode cannot be determined. Indeed, the change in time of the acute hypoxic region does not compensate for the lack of oxygenation at a specific moment and therefore does not influence the polarographic oxygen measurements.

  17. Polarographic study of the electrochemical properties of plutonium; Etude polarographique des proprietes electrochimiques du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Guichard, C [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The behaviour of the different degrees of oxidation of plutonium have been studied using a falling drop mercury electrode in a non-complexing medium: dilute perchloric acid. In this medium it is possible to carry out the polarographic determination of plutonium using the reduction step situated at - 0.54 V/ECS which corresponds to the passage from the degree of oxidation(V) to the degree(III). The modifications brought about by a complexing ion, acetate, are then observed and interpreted. The existence of two plutonium(IV) acetic complexes has been shown; one is a polymerized substance. (author) [French] Le comportement des differents degres d'oxydation du plutonium est etudie a l'electrode a gouttes de mercure dans un milieu non complexant: l'acide perchlorique dilue. Il est possible dans ce milieu d'effectuer le dosage polarographique du plutonium en utilisant la vague de reduction situee a - 0.54 V/ECS qui correspond au passage du degre d'oxydation(V) au degre(III). Les modifications apportees par un ion complexant, l'acetate, sont ensuite observees et interpretees. Deux complexes acetiques du plutonium(IV) ont ete mis en evidence, dont l'un est un compose polymerise. (auteur)

  18. Polarographic study of Cd(II)-Schiff base complexes and d.m.e. menthanol-water medium

    International Nuclear Information System (INIS)

    Patel, M.S.; Trivedi, T.; Vyas, D.N.

    1978-01-01

    Three Schiff base complexes of Cd 2+ have been investigated polarographically in 60% menthanol-water medium at 26 0 C. The Schiff bases used are salicyladehyde tris buffer (ST), benzaldehydetris buffer (BT) and vanillin tris buffer (VT). Cd-ST and Cd-VT complexes produce reversible reduction wave at dme, while Cd-BT gives a quasi reversible wave. Stability constants of the complexes have been determined and the standard overall electrode reaction rate constant (ksub(e)sup(o)) B of the Cd-BT complex is determined by three different methods. The log β values of complexes are : Cd-ST, 2.72; Cd-VT, 4.90; and Cd-BT, 4.41. (author)

  19. Polarographic behaviour of uranium (VI) in tributyl phosphate organic solutions

    International Nuclear Information System (INIS)

    Degueldre, C.A.; Meklati, M.

    1984-01-01

    U(VI) determination by D.C. and differential pulse polarography was studied in the organic solutions derived from tributyl phosphate - diluent extracts (after separation from nitric acid media) along with a selected aprotic solvent (i.e.: propylene carbonate and N,N-dimethylacetamide). Miscibility of the TBP-diluent (e.g. cyclohexane, n-hexane, kerosene, n-dodecane) phase with nitric acid as supporting electrolyte, either by addition or already present in the extract was larger in DMA than in PC. In the DMA organic mixture, U(VI) exhibited a DPP peak due to a one electron step, with Esub(p)=-0.4 V (position connected with H 2 O and HNO 3 concentrations). This peak which was proportionnel to the U(VI) concentration from 5x10 -6 to 10 -3 M can be used to determinate directly hexavalent uranium in the industrial organic extraction phases TBP-diluent. (orig.)

  20. Determination of pseudo multi-pulse production rate in GM counters by correlation analysis between signal pulses

    International Nuclear Information System (INIS)

    Hashimoto, Kengo; Ueda, Taizou

    1996-01-01

    A technique, based on the correlation analysis of signal pulses in time sequence, is proposed to determine the production rate of the pseudo multi-pulse in Geiger-Mueller (GM) counter. With a multi-channel scaler initiated by a signal pulse, subsequent pulses are recorded in sequence. The production of the multi-pulse increases the counting probability immediately after the initiation. By examining the deviation of the measured probability from the ideal counting probability, the production rate and the average lag time to produce the multi-pulse can be determined. By the use of the present technique, the production rate and the average lag time were obtained for the various GM tubes. These results indicate that the consumption of the quench gas results in a significant increase in the production rate but little variation in the lag time, and that the lag time strongly depends on the tube diameter. (author)

  1. Kinetic analysis of pulsed laser induced phosphorescence for uranium determination

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.

    2003-01-01

    The laser induced kinetic phosphorescence allows the uranium determination in different kind of matrices, with a lower detection limit than those reached by other spectroscopic methods. It involves the uranyl ions excitation by a pulsed dye-laser source, followed by temporal resolution of the phosphorescence. This method is used for the determination of trace quantities of uranium in aqueous solution, with a suitable complexant agent, without chemical separation before the analysis. The objective of this paper is to present the results of uranium determinations in different standard samples, water, soil, filter and urine, and a comparison with other methods such as fluorimetry, alpha spectrometry and mass spectrometry. Moreover, the measurement conditions, the advantages and disadvantages, the sample preparation, the interferences and the detection limit are described. (author)

  2. Calibration and testing of a polarographic sensor for the measurement of oxygen in seawater

    Energy Technology Data Exchange (ETDEWEB)

    Boniforti, R; Dell' Amico, F; Marri, P

    1987-04-01

    The procedures for the calibration and testing of a polarographic oxygen sensor, mounted on a CTD probe, are reported. As an example of in-field use, oxygen and temperature profiles obtained in Fossa del Pomo (Central Adriatic Sea), are given.

  3. Determination of Zalcitabine in Medicaments by Differential Pulse Voltammetry

    Directory of Open Access Journals (Sweden)

    Katia Christina Leandro

    2013-01-01

    Full Text Available The zalcitabine (ddC has been extensively used in the treatment of HIV patients due to its antiretroviral activity. The quality control of this active principle in medications is of outstanding importance to public health. The principal objective of the current study was the development of an alternative analytical methodology for the zalcitabine determination using a voltammetric process. The zalcitabine gives a reduction peak (at -1.22 V versus Ag/AgCl at the hanging mercury drop electrode (HMDE. The differential pulse voltammetric response is evaluated with respect to the scan rate (20 mV/s, pulse amplitude (50 mV, support electrolyte (Clark-Lubs buffer, pH (2.0, and other variables. The response is linear over the 10.0 to 28.0 mg/L (47 to 133 μM concentration range, and the detection limit is 2.08 mg/L. The validation of this method was realized using a governmental Brazilian document (Inmetro, 2007 and the results are reported for medication drugs.

  4. Picoseconds pulse generation and pulse width determination processes of a distributed feedback dye laser

    International Nuclear Information System (INIS)

    Abdul Ghani, B.; Hammadi, M.

    2004-08-01

    A mathematical model has been developed to describe the dynamic emission of Nd-glass, distributed feedback dye laser (DFDL), and periodical grating temperature. The suggested model allows the investigation of the time behavior of Nd-glass laser and DFDL pulsed. Moreover, it allows studying the effect of the laser input parameters of Nd-glass laser on the spectral characteristics of the output DFDL pulses such as pulse width, delay time, and time separation

  5. Differential Pulse Anodic Stripping Voltammetry for Mercury Determination

    Directory of Open Access Journals (Sweden)

    Vereștiuc Paul C.

    2015-07-01

    Full Text Available In the present work voltammetric investigations have been performed on HgCl2 aqueous solutions prepared from a Cz 9024 reagent. Carbon paste electrode (CPE, eriochrome black T modified carbon paste electrode (MCPE/EBT and KCl 1M as background electrolyte, were involved within the experimental procedures. Cyclic voltammetry (CV has been performed in order to compare the behaviour of the two electrodes in both K3[Fe(CN6] and mercury calibration aqueous solution. Differential pulse anodic stripping voltammetry (DPASV was used to determine the most suitable parameters for mercury determination. All experiments were performed at 25 ± 1 ℃, using an electrochemical cell with three-electrodes connected to an Autolab PG STAT 302N (Metrohm-Autolab potentiostat that is equipped with Nova 1.11 software. The measured potential values were generated by using the silver chloride electrode (AgClE as reference and a platinum wire electrode as auxiliary. A series of time depending equations for the pre-concentration and concentration steps were established, with the observation that a higher sensitivity can be obtained while increasing the pre-concentration time. DPASV were drawn using the CPE in 11.16 % coriander, as mercury complex, the voltamograms signals indicating mercury oxidation, with signal intensity increasing in time.

  6. Direct and indirect methods for the determination of vitamin K3 using differential pulse polarography and application to pharmaceuticals.

    Science.gov (United States)

    Somer, Güler; Doğan, Mehmet

    2008-11-01

    Two methods for the determination of vitamin K(3) have been developed. Vitamin K(3) in its oxidized form is determined by direct and indirect methods. Its standard solution was prepared by the indirect method using Ti(III) as reducing agent. For this purpose vitamin K(3) (menadion) in a clinical injection solution, which is in its hydroquinone form in the presence of sulfite, is oxidized with oxygen. In 0.2 M HAc and 0.02 M HCl electrolyte vitamin K(3) and Ti(IV) have reduction peaks at -0.58 V at -0.82 V respectively. The reaction between Ti(III) and vitamin takes place quantitatively in a medium of 0.2 M HAc and 0.002 M HCl. After the reduction, the reaction product Ti(IV) is followed from its polarographic peak at about -0.82 V. The most important result in this work is that, with this method vitamin K(3) can be standardized and after standardization this solution can be used for the direct determination in routine analysis with a very simple and fast method, using only the peak at -0.71 V in 0.2 M HAc medium. Both direct and indirect methods have been used for the determination of Vitamin K(3) in a clinical injection solution. The limit of quantification (LOQ) was 1.5x10(-6) M and in both methods the detection limit found was 7x10(-7) M.

  7. Differential Pulse Anodic Stripping Voltammetry for Mercury Determination

    OpenAIRE

    Vereștiuc Paul C.; Tucaliuc Oana-Maria; Breabăn Iuliana G.; Crețescu Igor; Nemțoi Gheorghe

    2015-01-01

    In the present work voltammetric investigations have been performed on HgCl2 aqueous solutions prepared from a Cz 9024 reagent. Carbon paste electrode (CPE), eriochrome black T modified carbon paste electrode (MCPE/EBT) and KCl 1M as background electrolyte, were involved within the experimental procedures. Cyclic voltammetry (CV) has been performed in order to compare the behaviour of the two electrodes in both K3[Fe(CN)6] and mercury calibration aqueous solution. Differential pulse anodic st...

  8. Pressure balanced type membrane covered polarographic oxygen detectors for use in high temperature-high pressure water, (1)

    International Nuclear Information System (INIS)

    Nakayama, Norio; Uchida, Shunsuke

    1984-01-01

    A pressure balanced type membrane covered polarographic oxygen detector was developed to determine directly oxygen concentrations in high temperature, high pressure water without cooling and pressure reducing procedures. The detector is characterized by the following features: (1) The detector body and the membrane for oxygen penetration are made of heat resistant resin. (2) The whole detector body is contained in a pressure chamber where interior and exterior pressures of the detector are balanced. (3) Thermal expansion of the electrolyte is absorbed by deformation of a diaphragm attached to the detector bottom. (4) The effect of dissolved Ag + on the signal current is eliminated by applying a guard electrode. As a result of performance tests at elevated temperature, it was demonstrated that a linear relationship between oxygen concentration and signal current was obtained up to 285 0 C, which was stabilized by the guard electrode. The minimum O 2 concentration detectable was 0.03ppm (9.4 x 10 -7 mol/kg). (author)

  9. Polarographic investigation of complexing kinetics of polyacrylate anions with cadmium ions

    International Nuclear Information System (INIS)

    Avlyanov, Zh.K.; Kabanov, N.M.; Zezin, A.B.; Askarov, M.A.

    1990-01-01

    The processes which occur during the reduction of cadmium ions from polymer-metallic complexes (PMC) are studied for the purposes of polarographic investigation of complexing kinetics of polyacrylate anions (PAA) of different molecular masses with cadmium ions in KCl aqueous solutions. An expression is derived for establishing semiwave potential. PMC formation and dissociation reduction rate constants are calculated. It is shown that intramolecular reorderings required for the formation of a two-coordinate complex proceed much slower as compared to the diffusion of free ions

  10. Determination of pulse profile characteristics of multi spot retinal photocoagulation lasers.

    Science.gov (United States)

    Clarkson, Douglas McG; Makhzoum, Osama; Blackburn, John

    2015-10-01

    A system is described for determination of discrete pulse train characteristics of multi spot laser delivery systems for retinal photocoagulation. While photodiodes provide an ideal detection mechanism, measurement artifacts can potentially be introduced by the spatial pattern of the delivered beam relative to a discrete photodiode element. This problem was overcome by use of an integrating sphere to produce a uniform light field at the site of the photodiode detector. A basic current driven photodiode detection circuit incorporating an operational amplifier was used to generate a signal captured by a commercially available USB interface device at a rate of 10 kHz. Studies were undertaken of a Topcon Pascal Streamline laser system with output at a wavelength of 577 nm (yellow). This laser features the proprietary feature of 'Endpoint Management' ™ where pulses can be delivered as 100% of set energy levels with visible reaction on the retina and also at a reduced energy level to create potentially non visible but clinically effective lesions. Using the pulse train measurement device it was identified that the 'Endpoint Management' ™ delivery mode of pulses of lower energy was achieved by reducing the pulse duration of pulses for non-visible effect pulses while maintaining consistent beam power levels within the delivered pulse profile. The effect of eye geometry in determining safety and effectiveness of multi spot laser delivery for retinal photocoagulation is discussed. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Pulsed neutron well logging apparatus having means for determining background radiation

    International Nuclear Information System (INIS)

    Randall, R.R.

    1979-01-01

    A neutron generator in a well logging instrument is periodically pulsed and has an off period between pulses of 1000 microseconds. A neutron detector is gated on at intervals of 400 to 500, 550 to 650, and 700 to 800 microseconds, respectively, following the termination of each burst of fast neutrons. Circuitry is provided for determining the background radiation and for determining the macroscopic absorption. 3 claims

  12. Polarographic and potentiometric studies on some binary and ternary complex systems of dioxouranium(VI)

    International Nuclear Information System (INIS)

    Janarthanam, M.; Sivasankar, B.; Rengaraj, K.; Nair, M.S.

    1995-01-01

    The relative coordinating abilities of donor sites in the potentially tridentate ligands viz., asparagine, glutamine, aspartic acid and glutamic acid towards uranyl ion have been investigated by polarographic and pH-metric techniques. The metal ion forms 1:2 complexes under polarographic conditions. However, only 1:1 complex is observed under pH-metric conditions, where 1:2 complexes do not proceed due to extensive hydrolysis of the metal ion. The relative variations of ΔE 1/2 with pH and ligand concentration supported by conductometric titration data indicate that the primary amino groups in the amino acids are not involved in coordination with uranyl ion. Further, the amide groups in asparagine and glutamine also do not participate in coordination thus rendering these ligands unidentate. In aspartic and glutamic acid complexes, seven- and eight- membered chelate rings are formed involving two terminal carboxyl groups. The mixed ligand complex equilibria of uranyl ion involving aspartic acid/glutamic acid as primary ligands (A) and maleic acid, malonic acid, succinic acid and lactic acid as secondary ligands (B) have also been studied by computer based numerical evaluation of pH titration data. The concentration profiles have indicated the favorability of the formation of ternary complexes in general as reflected in the Δlog K values. (author). 10 refs., 1 fig., 1 tab

  13. Polarographic studies about indium (III) behaviour in aqueous media of sodium azide

    International Nuclear Information System (INIS)

    Tokoro, R.

    1988-01-01

    The present study shows some polarographic behavior of indium (III) in azide media that is close those observed in a thiocyanate solution. The presence of azide ligand decreases the overpotential in the discharge of indium whose catalytic character can be explained by formation of an azide bridge between electrode and indium (III) increasing the speed of electron transfer. The discharge of indium in azide media is diffusion controlled. As the azide concentration is increased the half wave potential displaces in the cathodic direction. This displacement is due to complex formation. The number of electrons, n, involved in the total process was estimates by the reversible polarographic equation to be 2,7. The potentiostatic coulometry of indium in azide/hydrazoic acid buffer showed a catalytic process where the chemistry regeneration was performed by reaction of hydrazoic acid and indium amalgam. The electrochemistry evidence was the constancy of current as the electrolysis proceeded. The chemistry aspect was the presence of ammonium cation in electrolysed solution. The catalytic process with chemistry regeneration and the formation of a bridge by azide could explain the higher value of current in azide media compared to perchlorate solution. (author) [pt

  14. Research on determine the absolute neutron output of distributed pulse generators

    International Nuclear Information System (INIS)

    Li Bojun; Tang Zhangkui; Wang Dong; Yang Gaozhao; Peng Taiping

    2009-01-01

    In order to determine the absolute neutron output of distributed pulse generators, we deduced equivalent length to deal with experimental data, according to the different layout and weighting of multiple pulse generators. The deposited energy in scintillation crystal and the integral flux which drilling through crystal interface was simulated by MCNP code. The result shows the simulated proportion of different distributed pulse generators is approximately agreed with experimental data. The validity of the equivalent length model was proved by the consistent results between calculation and experimental data. (authors)

  15. Polarographic study of mixed-ligand complexes of cadmium(II) with L-amino acid and vitamin B5

    International Nuclear Information System (INIS)

    Jain, Alok K.; Khan, Farid

    1998-01-01

    A survey of literature shows that ternary complexes of Cd II with L-amino acids and vitamin B 5 have not been studied so far. The present communication reports the formation of mixed-ligand complexes of Cd II with L-amino acids as primary ligands and vitamin B 5 as secondary ligand, studied by polarographic technique. (author)

  16. Determination of molybdenum in uranium by differential pulse polarography

    International Nuclear Information System (INIS)

    Purwanto, A.; Iswani, G.S.

    1996-01-01

    The separation an determination of Mo (VI) in uranium dioxid (UO 2 ) samples by polarography method were studied. The determination of Mo(VI) was based on electrochemistry reduction of molybdenum (VI) quinolinolate complex (Mo VI O 2 Q 2 ). To decrease the matrix influence, this complex was extracted into chloroform. After chloroform phase was evaporate at room temperature, residues were dissolved with N,N-Dimethyl formamide (DMF). Potential wave reduction of Mo(VI) at -0,48 volt versus Ag/AgCl/KCl saturated in supporting electrolyte buffer acetate 1 M (1M CH 3 COOH-1M CH 3 COONH 4 ). Extraction was done in 0.3 M H 2 SO 4 media at optimum pH of 2.0 and 4 % oxine in 0.5 M H 2 SO 4 was used as complex compound. Extraction two times with 10 ml chloroform for 5 minutes each ratio of organic water was 1:5. This method was used to determine Mo (VI) in concentration range of 4.8 -12 μg in the presence of 200 mg uranium. It was found recovery of Mo (VI) was 95%. Mo (VI) contents in UO 2 samples determined by standard addition was 5.26±0.41 μg/g. (author)

  17. Determination of pulse energy dependence for skin denaturation from 585nm fibre laser

    Science.gov (United States)

    Mujica-Ascencio, S.; Velazquez-Gonzalez, J. S.; Mujica-Ascencio, C.; Alvarez-Chavez, J. A.

    2014-05-01

    In this paper, simulation and mathematical analysis for the determination of pulse energy from a Q-switched Yb3+-doped fibre laser is required in Port Wine Stain (PWS) treatment. The pulse energy depends on average power, gain, volume, repetition rate and pulse duration. In some treatments such as Selective Photothermolysis (SP), the peak power at the end of the optical fibre and pulse duration can be obtained and modified via a cavity design. For that purpose, a 585nm optical fibre laser full design which considers all of the above besides the average losses through the optical devices proposed for the design and the Ytterbium optical fibre overall gain will be presented.

  18. A novel approach to determine the interphase transformer inductance of 18 pulse rectifiers

    International Nuclear Information System (INIS)

    Sefa, Ibrahim; Altin, Necmi

    2009-01-01

    The interphase transformer inductance seriously affects the performance of 18 pulse rectifiers. Low inductance values cause non-characteristic harmonics whereas high inductance values increase the rectifier cost and size. Hence, determination of the interphase transformer inductance value is an important problem in the design of 18 pulse rectifiers. In this paper, an approach to determine the optimum inductance value of an interphase transformer is proposed and a practical formula is introduced. The proposed approach has been validated with simulation and experimental studies carried out with designed capacitive loaded autotransformer based 18 pulse rectifier for different IPT inductance values at different load levels. Experimental and simulation results show that cost effective interphase transformer inductance value can be determined with the proposed approach and this value reduces the line current harmonics and improves power factor drastically.

  19. Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

    Science.gov (United States)

    Boehme, Stefan; Duenges, Bastian; Klein, Klaus U; Hartwich, Volker; Mayr, Beate; Consiglio, Jolanda; Baumgardner, James E; Markstaller, Klaus; Basciani, Reto; Vogt, Andreas

    2013-01-01

    Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min(-1)) on MFPF-PO2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-PO2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R(2) = 0.93; P0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. MFPF-derived PO2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based PO2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-PO2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase.

  20. Determination of diffusion coefficients in polypyrrole thin films using a current pulse relaxation method

    Science.gov (United States)

    Penner, Reginald M.; Vandyke, Leon S.; Martin, Charles R.

    1987-01-01

    The current pulse E sub oc relaxation method and its application to the determination of diffusion coefficients in electrochemically synthesized polypyrrole thin films is described. Diffusion coefficients for such films in Et4NBF4 and MeCN are determined for a series of submicron film thicknesses. Measurement of the double-layer capacitance, C sub dl, and the resistance, R sub u, of polypyrrole thin films as a function of potential obtained with the galvanostatic pulse method is reported. Measurements of the electrolyte concentration in reduced polypyrrole films are also presented to aid in the interpretation of the data.

  1. The second phase of bipolar, nanosecond-range electric pulses determines the electroporation efficiency.

    Science.gov (United States)

    Pakhomov, Andrei G; Grigoryev, Sergey; Semenov, Iurii; Casciola, Maura; Jiang, Chunqi; Xiao, Shu

    2018-03-29

    Bipolar cancellation refers to a phenomenon when applying a second electric pulse reduces ("cancels") cell membrane damage by a preceding electric pulse of the opposite polarity. Bipolar cancellation is a reason why bipolar nanosecond electric pulses (nsEP) cause weaker electroporation than just a single unipolar phase of the same pulse. This study was undertaken to explore the dependence of bipolar cancellation on nsEP parameters, with emphasis on the amplitude ratio of two opposite polarity phases of a bipolar pulse. Individual cells (CHO, U937, or adult mouse ventricular cardiomyocytes (VCM)) were exposed to either uni- or bipolar trapezoidal nsEP, or to nanosecond electric field oscillations (NEFO). The membrane injury was evaluated by time-lapse confocal imaging of the uptake of propidium (Pr) or YO-PRO-1 (YP) dyes and by phosphatidylserine (PS) externalization. Within studied limits, bipolar cancellation showed little or no dependence on the electric field intensity, pulse repetition rate, chosen endpoint, or cell type. However, cancellation could increase for larger pulse numbers and/or for longer pulses. The sole most critical parameter which determines bipolar cancellation was the phase ratio: maximum cancellation was observed with the 2nd phase of about 50% of the first one, whereas a larger 2nd phase could add a damaging effect of its own. "Swapping" the two phases, i.e., delivering the smaller phase before the larger one, reduced or eliminated cancellation. These findings are discussed in the context of hypothetical mechanisms of bipolar cancellation and electroporation by nsEP. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Determination of electric field threshold for electrofusion of erythrocyte ghosts. Comparison of pulse-first and contact-first protocols.

    OpenAIRE

    Wu, Y; Montes, J G; Sjodin, R A

    1992-01-01

    Rabbit erythrocyte ghosts were fused by means of electric pulses to determine the electrofusion thresholds for these membranes. Two protocols were used to investigate fusion events: contact-first, and pulse-first. Electrical capacitance discharge (CD) pulses were used to induce fusion. Plots of fusion yield vs peak field strength yielded curves that intersected the field strength axis at positive values (pseudothresholds) which depended on the protocol and decay half time of the pulses. It wa...

  3. Determination of the Young's modulus of pulsed laser deposited epitaxial PZT thin films

    NARCIS (Netherlands)

    Nazeer, H.; Nguyen, Duc Minh; Woldering, L.A.; Abelmann, Leon; Rijnders, Augustinus J.H.M.; Elwenspoek, Michael Curt

    2011-01-01

    We determined the Young’s modulus of pulsed laser deposited epitaxially grown PbZr0.52Ti0.48O3 (PZT) thin films on microcantilevers by measuring the difference in cantilever resonance frequency before and after deposition. By carefully optimizing the accuracy of this technique, we were able to show

  4. Determination of modeling parameters for power IGBTs under pulsed power conditions

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Gregory E [Los Alamos National Laboratory; Van Gordon, Jim A [U. OF MISSOURI; Kovaleski, Scott D [U. OF MISSOURI

    2010-01-01

    While the power insulated gate bipolar transistor (IGRT) is used in many applications, it is not well characterized under pulsed power conditions. This makes the IGBT difficult to model for solid state pulsed power applications. The Oziemkiewicz implementation of the Hefner model is utilized to simulate IGBTs in some circuit simulation software packages. However, the seventeen parameters necessary for the Oziemkiewicz implementation must be known for the conditions under which the device will be operating. Using both experimental and simulated data with a least squares curve fitting technique, the parameters necessary to model a given IGBT can be determined. This paper presents two sets of these seventeen parameters that correspond to two different models of power IGBTs. Specifically, these parameters correspond to voltages up to 3.5 kV, currents up to 750 A, and pulse widths up to 10 {micro}s. Additionally, comparisons of the experimental and simulated data will be presented.

  5. Determination of ablation threshold for composite resins and amalgam irradiated with femtosecond laser pulses

    International Nuclear Information System (INIS)

    Freitas, A Z; Samad, R E; Zezell, D M; Vieira Jr, N D; Freschi, L R; Gouw-Soares, S C

    2010-01-01

    The use of laser for caries removal and cavity preparation is already a reality in the dental clinic. The objective of the present study was to consider the viability of ultrashort laser pulses for restorative material selective removal, by determining the ablation threshold fluence for composite resins and amalgam irradiated with femtosecond laser pulses. Lasers pulses centered at 830 nm with 50 fs of duration and 1 kHz of repetition rate, with energies in the range of 300 to 770 μJ were used to irradiate the samples. The samples were irradiated using two different geometrical methods for ablation threshold fluence determinations and the volume ablation was measured by optical coherence tomography. The shape of the ablated surfaces were analyzed by optical microscopy and scanning electron microscopy. The determined ablation threshold fluence is 0.35 J/cm 2 for the composite resins Z-100 and Z-350, and 0.25 J/cm 2 for the amalgam. These values are half of the value for enamel in this temporal regime. Thermal damages were not observed in the samples. Using the OCT technique (optical coherence tomography) was possible to determine the ablated volume and the total mass removed

  6. Pulsed neutron well logging apparatus having means for determining background radiation

    International Nuclear Information System (INIS)

    Randall, R.R.

    1979-01-01

    A neutron generator in a well logging instrument is periodically pulsed and has an off period between pulses of 1000 microseconds. A neutron detector is gated on at intervals of 400 to 500, 550 to 650, and 700 to 800 microseconds, respectively, following the termination of each burst of fast neutrons. Circuitry is provided for determining the background radiation by the equation: B = N 1 X N 3 - N 2 2 /N 1 + N 3 - 2N 2 where B is the background, and N 1 , N 2 and N 3 are the counts observed during the three gates, respectively. Circuitry is also provided for determining the macroscopic absorption (Σ) from the equation: Σ = 1/VΔt Log [N 1 - B/N 2 - B] where V is the velocity of thermal neutrons, being a constant and Δt represents an increment of time

  7. Emission spectrochemical determination of boron in steels with pulse height distribution analyzer

    International Nuclear Information System (INIS)

    Ito, Minao; Sato, Shoki; Fushida, Hiroshi; Narita, Masanao

    1983-01-01

    The method for rapid determination of total, acid soluble and insoluble boron was established by using emission spectrochemical apparatus equipped with pulse height distribution analyzer. By using the analyzer, emission intensity can be expressed as different level intensity of pulse height distribution. It was made clear that soluble and insoluble boron had different contribution degree to each intensity and that this contribution degree varied at different pre-spark. Therefore, it is necessary for accurate determination of boron that this contribution degree should be corrected by using two intensities, of which contribution degrees are different. It was found on this two intensities method that total and soluble boron corresponded well to 50 % intensities at zero pre-spark and at 2000 pre-spark and that insoluble boron corresponded well to 70 % intensity at zero pre-spark and 50 % intensity at 2000 pre-spark. (author)

  8. Differential pulse anodic stripping voltametry for ultratrace determination of cadmium and lead in Antarctic snow

    International Nuclear Information System (INIS)

    Scarponi, G.; Barbante, C.; Cescon, P.

    1994-01-01

    Differential pulse anodic stripping voltametry has sufficient sensitivity to be used for direct determination of heavy metals in Antarctic snow, thus avoiding long and contamination-prone enrichment procedures. A result of particular concern to global change studies can be drawn from these preliminary data: lead concentration in Antarctic snow decreased rapidly during the 1980s from about 10-15 pg/g to 2-4 pg/g in 1991. (authors). 16 refs., 3 figs., 1 tab

  9. Determination of one-electron reduction potentials of some radiosensitive compounds by pulse radiolysis

    International Nuclear Information System (INIS)

    Zuo Zhihua; Yao Side; Li Hucheng; Lin Nianyun; Jin Yizun

    1994-01-01

    One-electron reduction potential (E 7 1 ) is one of the important parameters of radiosensitive compound with high electron affinity. In this work one-electron reduction potentials of some radiosensitizers, such as Miso, 911, CMNa, SMU-1, SMU-2, SMD, SNN, S 3 and BSO, were determined pulse radiolytically by using anthraquinone-2-sulfate (AQS), duroquinone (DQ) and methyl viologen (MV 2+ ) as references

  10. Pulse polarography - special application; Polarographie a impulsions - applications particulieres

    Energy Technology Data Exchange (ETDEWEB)

    Chapron, Y [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1967-07-01

    The calculation of the current on a plane electrode in particular conditions is presented briefly, the first part of the report then consists of a theoretical and methodological presentation of pulse polarography. The calculation of the current in pulse polarography is given for different modes of measurement and for redox systems of variable reversibility. Various extensions are proposed with a view to extending the field of application of the method. The second part presents two particular applications. One application is to analytical chemistry: organometallic complexes applied to the pulse polarographic analysis; the other application is to electrochemical kinetics using integral pulse polarography. This research has enabled us to determine, in the first case, elements present in minute traces, and in the second case the kinetic parameters of an electrochemical reaction which is too fast to be analyzed by conventional polarography. (author) [French] Apres un rappel sur le calcul du courant sur electrode plane dans des conditions precises, la premiere partie du memoire est consacree a l'expose theorique et methodologique de la polarographie a impulsions. Le calcul du courant en polarographie a impulsions est donne pour divers modes de mesures et pour des systemes redox de reversibilites variees. Diverses extensions sont proposees de facon a elargir le domaine d'application de la methode. La deuxieme partie introduit deux applications particulieres. Une application a la chimie analytique: les complexes organometalliques appliques a l'analyse pulsopolarographique et une application a la cinetique electrochimique par polarographie a impulsions integrale. Ces recherches nous ont permis de determiner dans le premier cas, des elements a l'etat de traces infimes, dans le deuxieme cas, les parametres cinetiques d'une reaction electrochimique trop rapide pour etre analysee par polarographie classique. (auteur)

  11. Multi Frequency Phase Fluorimetry (MFPF) for Oxygen Partial Pressure Measurement: Ex Vivo Validation by Polarographic Clark-Type Electrode

    Science.gov (United States)

    Boehme, Stefan; Duenges, Bastian; Klein, Klaus U.; Hartwich, Volker; Mayr, Beate; Consiglio, Jolanda; Baumgardner, James E.; Markstaller, Klaus; Basciani, Reto; Vogt, Andreas

    2013-01-01

    Background Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. Methodology/Principal Findings MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory setup (human packed red blood cells, haematocrit of 30%). The impacts of temperature (20, 30, 40°C) and blood flow (0.8, 1.6, 2.4, 3.2, 4.0 L min−1) on MFPF-PO2 measurements were assessed. MFPF response time in the gas- and blood-phase was determined. Porcine MFPF-PO2 ranged from 63 to 749 mmHg; the corresponding CTE samples from 43 to 712 mmHg. Linear regression: CTE = 15.59+1.18*MFPF (R2 = 0.93; PPO2 ranged from 20 to 567 mmHg and CTE samples from 11 to 575 mmHg. Linear regression: CTE = −8.73+1.05*MFPF (R2 = 0.99; PPO2 due to variations of temperature were less than 6 mmHg (range 0–140 mmHg) and less than 35 mmHg (range 140–750 mmHg); differences due to variations in blood flow were less than 15 mmHg (all P-values>0.05). MFPF response-time (monoexponential) was 1.48±0.26 s for the gas-phase and 1.51±0.20 s for the blood-phase. Conclusions/Significance MFPF-derived PO2 readings were reproducible and showed excellent correlation and good agreement with Clark-type electrode-based PO2 measurements. There was no relevant impact of temperature and blood flow upon MFPF-PO2 measurements. The response time of the MFPF FOXY-AL300 probe was adequate for real-time sensing in the blood phase. PMID:23565259

  12. Pulse shape analysis and position determination in segmented HPGe detectors: The AGATA detector library

    Energy Technology Data Exchange (ETDEWEB)

    Bruyneel, B. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Service de Physique Nucleaire, CEA Saclay, Gif-sur-Yvette (France); Birkenbach, B.; Reiter, P. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany)

    2016-03-15

    The AGATA Detector Library (ADL) was developed for the calculation of signals from highly segmented large volume high-purity germanium (HPGe) detectors. ADL basis sets comprise a huge amount of calculated position-dependent detector pulse shapes. A basis set is needed for Pulse Shape Analysis (PSA). By means of PSA the interaction position of a γ -ray inside the active detector volume is determined. Theoretical concepts of the calculations are introduced and cover the relevant aspects of signal formation in HPGe. The approximations and the realization of the computer code with its input parameters are explained in detail. ADL is a versatile and modular computer code; new detectors can be implemented in this library. Measured position resolutions of the AGATA detectors based on ADL are discussed. (orig.)

  13. Determination of carbohydrates using pulsed amperometric detection combined with anion exchange separations

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, W.T.; Pohl, C.A.; Rubin, R.

    1987-06-01

    Carbohydrates, including the monosaccharides commonly found in wood and wood pulp hydrolyzates, are separated by anion exchange chromatography using hydroxide and acetate eluants and are determined using pulsed amperometric detection. The detection method is based on oxidizing the sugars in a flow-through electrochemical cell equipped with a gold working electrode. A repeating cycle of three potentials is used: the first to oxidize the carbohydrates and measure the current generated, and two subsequent pulses to clean the electrode surface of oxidation products. The method is fast, sensitive, and requires no pre-column derivatization. It is applied to a sample of hydrolyzed wood pulp, which can be analyzed after minimal sample preparation. Detection limits are of the order of 1 mg/kg for monosaccharides in a 50 micro L injection. (Refs. 8).

  14. Experimental determination of the thermal contact conductance between two solid surfaces by the energy pulse technique

    International Nuclear Information System (INIS)

    Rubin, Gerson Antonio

    1979-01-01

    An experimental procedure for the determination of the thermal contact conductance between two solid surfaces as a function of the contact pressure and the energy of the laser radiation has been developed using the laser pulse method. A rubi laser with variable energy levels was employed as a radiating pulse energy source. The laser beam was allowed to impinge perpendicularly on the front face of a electrolytic iron 73 4 . The temperature fluctuations resulting on the back surface of the sample was detected by a thermocouple, which Is coupled to a PDP-11/45 Computer 32 Kbytes of memory, through a Analog-Digital Converter. A theoretical function, derived exclusively for the problem mentioned in this work, was adjusted by a method of least square fitting of experimental results. This adjustment yielded the value of a parameter related to the contact conductance between two surfaces. The experimental error obtained for the thermal contact conductance was +- 4.9%. (author)

  15. Direct determination of molybdenum in seawater by adsorption cathodic stripping square-wave voltammetry.

    Science.gov (United States)

    Sun, Y C; Mierzwa, J; Lan, C R

    2000-06-30

    A reliable and very sensitive procedure for the determination of trace levels of molybdenum in seawater is proposed. The complex of molybdenum with 8-hydroxyquinoline (Oxine) is analyzed by cathodic stripping square-wave voltammetry based on the adsorption collection onto a hanging mercury drop electrode (HMDE). This procedure of molybdenum determination was found to be more favorable than differential pulse cathodic stripping voltammetry because of inherently faster scan rate and much better linearity obtained through the one-peak (instead of one-of-two peaks) calibration. The variation of polarographic peak and peak current with a pH, adsorption time, adsorption potential, and some instrumental parameters such as scan rate and pulse height were optimized. The alteration of polarographic wave and its likely mechanism are also discussed. The relationship between peak current and molybdenum concentration is linear up to 150 mug l(-1). Under the optimal analytical conditions, the determination limit of 0.5 mug l(-1) Mo was reached after 60 s of the stirred collection. The estimated detection limit is better than 0.1 mug l(-1) of Mo. The applicability of this method to analysis of seawater was assessed by the determination of molybdenum in two certified reference seawater samples (CASS-2 and NASS-2) and the comparison of the analytical results for real seawater samples (study on a vertical distribution of Mo in the seawater column) with the results obtained by Zeeman-corrected electrothermal atomization atomic absorption spectrometry (Zeeman ETAAS). A good agreement between two used methods of molybdenum determination was obtained.

  16. Pulse Generator

    Science.gov (United States)

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  17. Determination of transport and reaction swarm coefficients from the analysis of complex transient pulses from the pulsed Townsend experiment

    International Nuclear Information System (INIS)

    Bekstein, A; De Urquijo, J; Rodríguez-Luna, J C; Juárez, A M; Ducasse, O

    2012-01-01

    We present in this paper the interpretation and analysis of transient pulses from a pulsed Townsend experiment by solving the continuity equations of the charged carriers (electrons and ions) involved in the avalanche. The set of second order partial differential equations is solved by SIMAV, a simulator designed specifically for the pulsed Townsend avalanche. Complex situations involving processes such as electron detachment, ion-molecule reactions, Penning ionization and secondary electron emission from ion impact at the cathode, virtually impossible to solve analytically, are discussed here to illustrate the capability of the simulator to help explain the various reaction processes involved in the avalanche, and also to derive some of the transport and reaction coefficients.

  18. Determination of Selenium in infant formula by differential pulse cathodic stripping voltammetry

    Directory of Open Access Journals (Sweden)

    "Oveisi MR

    2002-07-01

    Full Text Available Selenium as a nonmetallic chemical element has received high attention of biologists because of its dual role as an essential trace nutrient and a toxic element. This interest has created a need for reliable analytical methods for determination of selenium. In this investigation determination of selenium by differential pulse cathodic stripping voltammetry and the influence of various parameters such as deposition potentials, deposition time. Cu concentration pH, etc. on selenium peak in voltammogram are described. Determination of selenium was accomplished in mixture of acetic acid, hydrochloric acid and sodium chloride buffer (pH=1 with a scan rate of 60 mv/s and a pulse height of 100 my by hanging mercury drop electrode (HMDE as working electrode. The solution was stirred during pre-electrolysis at - 350 mv (vs SCE for 30 s and the potential was scanned between - 350 mv and - 800 mv. The determination limit of the method was 0.005 mg/kg for the sample. The calibration curves were linear in the range of 0-30 μg/L (R2=0.996, p<0.001. Repeatability of the method at concentrations of 30 and 0.5 μg/L were 2.5 and 10.5% respectively.

  19. Identification of critical equipment and determination of operational limits in helium refrigerators under pulsed heat load

    Science.gov (United States)

    Dutta, Rohan; Ghosh, Parthasarathi; Chowdhury, Kanchan

    2014-01-01

    Large-scale helium refrigerators are subjected to pulsed heat load from tokamaks. As these plants are designed for constant heat loads, operation under such varying load may lead to instability in plants thereby tripping the operation of different equipment. To understand the behavior of the plant subjected to pulsed heat load, an existing plant of 120 W at 4.2 K and another large-scale plant of 18 kW at 4.2 K have been analyzed using a commercial process simulator Aspen Hysys®. A similar heat load characteristic has been applied in both quasi steady state and dynamic analysis to determine critical stages and equipment of these plants from operational point of view. It has been found that the coldest part of both the cycles consisting JT-stage and its preceding reverse Brayton stage are the most affected stages of the cycles. Further analysis of the above stages and constituting equipment revealed limits of operation with respect to variation of return stream flow rate resulted from such heat load variations. The observations on the outcome of the analysis can be used for devising techniques for steady operation of the plants subjected to pulsed heat load.

  20. Comparison of concentration pulse and tracer pulse chromatography: experimental determination of eluent uptake by bridged-ethylene hybrid ultra high performance liquid chromatography packings

    Science.gov (United States)

    Excess volume isotherms of acetonitrile and methanol sorbed on a C18 BEH UHPLC packing were determined over a range of pressure, temperature, flow rate and eluent composition. The isotherm measurements were carried out by two independent experimental methods, viz., concentration pulse and tracer pul...

  1. [Ambient air interference in oxygen intake measurements in liquid incubating media with the use of open polarographic cells].

    Science.gov (United States)

    Miniaev, M V; Voronchikhina, L I

    2007-01-01

    A model of oxygen intake by aerobic bio-objects in liquid incubating media was applied to investigate the influence air-media interface area on accuracy of measuring the oxygen intake and error value. It was shown that intrusion of air oxygen increases the relative error to 24% in open polarographic cells and to 13% in cells with a reduced interface area. Results of modeling passive media oxygenation laid a basis for proposing a method to reduce relative error by 66% for open cells and by 15% for cells with a reduced interface area.

  2. Evaluation of pulsed streamer corona experiments to determine the O* radical yield

    International Nuclear Information System (INIS)

    Van Heesch, E J M; Winands, G J J; Pemen, A J M

    2008-01-01

    The production of O* radicals in air by a pulsed streamer plasma is studied by integration of a large set of precise experimental data and the chemical kinetics of ozone production. The measured data comprise ozone production, plasma energy, streamer volume, streamer length, streamer velocity, humidity and gas-flow rate. Instead of entering input parameters into a kinetic model to calculate the end products the opposite strategy is followed. Since the amount of end-products (ozone) is known from the measurements the model had to be applied in the reverse direction to determine the input parameters, i.e. the O* radical concentration.

  3. Evaluation of pulsed streamer corona experiments to determine the O* radical yield

    Science.gov (United States)

    van Heesch, E. J. M.; Winands, G. J. J.; Pemen, A. J. M.

    2008-12-01

    The production of O* radicals in air by a pulsed streamer plasma is studied by integration of a large set of precise experimental data and the chemical kinetics of ozone production. The measured data comprise ozone production, plasma energy, streamer volume, streamer length, streamer velocity, humidity and gas-flow rate. Instead of entering input parameters into a kinetic model to calculate the end products the opposite strategy is followed. Since the amount of end-products (ozone) is known from the measurements the model had to be applied in the reverse direction to determine the input parameters, i.e. the O* radical concentration.

  4. DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM

    Directory of Open Access Journals (Sweden)

    Saryati Saryati

    2010-06-01

    Full Text Available The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV method at a hanging mercury drop electrode and in a carbonate buffer media was developed. It was found that the carbonate buffer show the strongest affinity for uranium and gives the best separation between the DPASV peaks of heavy metals impurities. The carbonate concentration markedly affects the oxidation and reduction the major and the minor constituents of the uranium samples. In 0.1 M carbonate buffer solution pH 10, copper, bismuth, thalium, lead, cadmium, zinc, could be determined without the removal of the uranium matrix. Recovery and relative standard deviation (RSD of this method was in the range of 174% - 85.2% for recovery and 36.8% - 1.2% for RSD. The larger error of analytical result was obtained for Zn at low concentration. In general, the analytic results error and RSD decreased with increasing metals concentration.   Keywords: heavy metal determination, differential pulse anodic stripping voltammetry, uranium

  5. Parameters affecting the determination of paraquat at silver rotating electrodes using differential pulse voltammetry

    Directory of Open Access Journals (Sweden)

    A. Farahi

    2014-08-01

    Full Text Available The electrochemical determination of aqueous paraquat PQ(II by differential pulse voltammetry at a solid rotating silver electrode (RSE is described. The aim of this work is to optimize all factors that can influence this determination. Potential wave forms, potential scan parameters and deposition time were examined for their effect on the paraquat peak shape and intensity. The best responses were obtained with differential pulse voltammetry in 0.1 mol L−1 Na2SO4 as supporting electrolyte using amplitude 50 mV, scan increment 5 mV, deposition time 120 s, frequency 50 s−1 and step amplitude 0.05 V. Electrochemical and mechanical surface cleaning, aimed at removing the amount of paraquat deposited onto the silver surface, were necessary for obtaining a good performance of the electrode. Response linearity, repeatability, accuracy and detection limit were also evaluated. The obtained detection limits were 7.1 × 10−9 mol L−1 and 2.8 × 10−9 mol L−1 for peak 1 and peak 2 respectively. The relative standard deviation (RSD was found to be 1.19% in 1.0 × 10−4 mol L−1 paraquat. The applicability of the RSE for PQ(II determination in milk samples, without any sample pretreatment, was successfully demonstrated.

  6. Determination of copper in whole blood by differential pulse adsorptive stripping voltammetry

    Directory of Open Access Journals (Sweden)

    Tarik Attar

    2014-02-01

    Full Text Available A selective and sensitive method for determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The method is based on adsorptive accumulation of the complexes of Cu (II ions with benzenesulfonyl hydrazide onto hanging mercury drop electrode (HMDE, followed by the reduction of the adsorbed species by differential pulse cathodic stripping voltammetry. The effect of various parameters such as supporting electrolyte, concentration of benzenesulfonyl hydrazide, accumulation potential, accumulation time and stirring rate on the selectivity and sensitivity were studied. The optimum conditions for determination of copper include perchloric acid 0.03 M, concentration of benzenesulfonyl hydrazide 7.5×10-5 M, the accumulation potential of -350 mV (vs. Ag/AgCl, the accumulation time of 50 s, and the scan rate of 50 mV s-1. Under optimized conditions, linear calibration curves were established for the concentration of Cu (II in the range of 0.62-275 ng mL-1, with detection limit of 0.186 ng mL-1 for Cu (II. The procedure was successfully applied to the determination of copper ion in whole blood samples.

  7. Determining the field emitter temperature during laser irradiation in the pulsed laser atom probe

    International Nuclear Information System (INIS)

    Kellogg, G.L.

    1981-01-01

    Three methods are discussed for determining the field emitter temperature during laser irradiation in the recently developed Pulsed Laser Atom Probe. A procedure based on the reduction of the lattice evaporation field with increasing emitter temperature is found to be the most convenient and reliable method between 60 and 500 K. Calibration curves (plots of the evaporation field versus temperature) are presented for dc and pulsed field evaporation of W, Mo, and Rh. These results show directly the important influence of the evaporation rate on the temperature dependence of the evaporation field. The possibility of a temperature calibration based on the ionic charge state distribution of field evaporated lattice atoms is also discussed. The shift in the charge state distributions which occurs when the emitter temperature is increased and the applied field strength is decreased at a constant rate of evaporation is shown to be due to the changing field and not the changing temperature. Nevertheless, the emitter temperature can be deduced from the charge state distribution for a specified evaporation rate. Charge state distributions as a function of field strength and temperature are presented for the same three materials. Finally, a preliminary experiment is reported which shows that the emitter temperature can be determined from field ion microscope observations of single atom surface diffusion over low index crystal planes. This last calibration procedure is shown to be very useful at higher temperatures (>600 K) where the other two methods become unreliable

  8. Simultaneous determination of three herbicides by differential pulse voltammetry and chemometrics.

    Science.gov (United States)

    Ni, Yongnian; Wang, Lin; Kokot, Serge

    2011-01-01

    A novel differential pulse voltammetry method (DPV) was researched and developed for the simultaneous determination of Pendimethalin, Dinoseb and sodium 5-nitroguaiacolate (5NG) with the aid of chemometrics. The voltammograms of these three compounds overlapped significantly, and to facilitate the simultaneous determination of the three analytes, chemometrics methods were applied. These included classical least squares (CLS), principal component regression (PCR), partial least squares (PLS) and radial basis function-artificial neural networks (RBF-ANN). A separately prepared verification data set was used to confirm the calibrations, which were built from the original and first derivative data matrices of the voltammograms. On the basis relative prediction errors and recoveries of the analytes, the RBF-ANN and the DPLS (D - first derivative spectra) models performed best and are particularly recommended for application. The DPLS calibration model was applied satisfactorily for the prediction of the three analytes from market vegetables and lake water samples.

  9. Determination of moisture in black coal using pulsed nuclear magnetic resonance spectrometry

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Sowerby, B.D.; Lynch, L.J.; Webster, D.S.

    1987-01-01

    Pulsed nuclear magnetic resonance (n.m.r.) spectrometry was investigated as a technique for moisture determination in fine product coal from eight Australian coal washeries. Measurements were made on samples of diameter 8 and 12 mm and length 10 and 120 mm at frequencies from 6.5 to 60 MHz. The ratio of intensities of the water and coal components in the free-induction decay signal can be used to determine moisture to within approx. 0.4-0.7 wt% over the range 0-26 wt% moisture, independent of sample density. This accuracy is independent of particle size (up to 1 mm) and little affected by coal rank, sample length or n.m.r. frequency. (author)

  10. Quantitative determination of arterial wall mechanics with pulse oximetric finger plethysmography.

    Science.gov (United States)

    Kato, R; Sato, J; Iuchi, T; Higuchi, Y

    1999-10-30

    The plethysmographic wave of pulse oximetry reflects arterial pulsation at the fingertip. Since arterial pressure and the pulsatile component of the arterial cross section represent the input and output of the fingertip arterial system, respectively, arterial wall mechanics may be delineated from their relationship. We aimed to construct a mathematical model of the fingertip arterial wall from the relationship between the plethysmographic wave and arterial pressure. The pulse oximetric plethysmographic signal at the forefinger and pressure at the ipsilateral radial artery were measured. Employing the data, simple mathematical models with one to four mechanical elements were tested in terms of the goodness of fit and the physiological implications. The determined model was applied to the data obtained during administration of vasoactive agents in anesthetized patients. The mathematical model suited for describing arterial wall mechanics was a four-element, two-compartment model. The two compartments represent passive mechanical and active contractile properties, respectively. In the application of the model to the anesthetized patients, the vasoactive agents produced changes in the model parameters that implied mechanical alterations in the arterial wall. These findings suggest the benefit of the four-element, two-compartment model in analyzing peripheral vascular wall mechanics influenced by various stimuli in intensive care and anesthesia.

  11. Developments in Pulsed Neutron Activation for Determination of Water Flow in Pipes

    Energy Technology Data Exchange (ETDEWEB)

    Mattsson, Haakan

    2003-06-01

    In PNA (pulsed neutron activation) it is important that the measured data can be related to the total mass flow. In this thesis two fundamental problems of the measurement technique and data treatment have been investigated: transport/mixing and background radiation. The principle of PNA is to introduce a radioactive substance into a pipe by bombarding fluid in the pipe with neutron pulses. The fluid in the pipe is activated and subsequently transported and mixed with the flow. Gamma radiation emitted from the activity is measured with one or two detectors downstream from the activation point. The time-resolved signal from the detectors is used to calculate the average velocity of the water flow. Due to the short distance between the neutron generator and the pipe the activity in the pipe becomes highly inhomogeneous. The transport and mixing of the activity were simulated using colour which was injected into the flow. It was found that the inhomogeneous activity distribution must be taken into account if the precision of the measurements is to be improved. The shape of the background in PNA affects the shape and position of the time spectrum. The nature of the background has been determined using one detector upstream and one downstream of the neutron generator. The background was shown to be caused by {sup 16}N. A method that subtracts the background from the PNA time spectrum was also developed.

  12. Determination of the wavelength dependence of the differential pathlength factor from near-infrared pulse signals

    Science.gov (United States)

    Kohl, Matthias; Nolte, Christian; Heekeren, Hauke R.; Horst, Susanne; Scholz, Udo; Obrig, Hellmuth; Villringer, Arno

    1998-06-01

    For the calculation of changes in oxyhaemoglobin, deoxyhaemoglobin and the redox state of cytochrome-c-oxidase from attenuation data via a modified Beer-Lambert equation the wavelength dependence of the differential pathlength factor (DPF) has to be taken into account. The DPF, i.e. the ratio of the mean optical pathlength and the physical light source-detector separation at each wavelength, determines the crosstalk between the different concentrations and is therefore essential for a sensitive detection of chromophore changes. Here a simple method is suggested to estimate the wavelength dependence of the DPF from pulse-induced attenuation changes measured on the head of adult humans. The essence is that the DPF is the ratio of the attenuation changes over absorption coefficient changes, and that the spectral form of the pulse correlated absorption coefficient change can be assumed to be proportional to the extinction coefficient of blood. Indicators for the validity of the DPF derived for wavelengths between 700 and 970 nm are the stability of the calculated haemoglobin and cytochrome signals with variations of the wavelength range included for their calculation and its overall agreement with the data available from the literature.

  13. Developments in Pulsed Neutron Activation for Determination of Water Flow in Pipes

    International Nuclear Information System (INIS)

    Mattsson, Haakan

    2003-06-01

    In PNA (pulsed neutron activation) it is important that the measured data can be related to the total mass flow. In this thesis two fundamental problems of the measurement technique and data treatment have been investigated: transport/mixing and background radiation. The principle of PNA is to introduce a radioactive substance into a pipe by bombarding fluid in the pipe with neutron pulses. The fluid in the pipe is activated and subsequently transported and mixed with the flow. Gamma radiation emitted from the activity is measured with one or two detectors downstream from the activation point. The time-resolved signal from the detectors is used to calculate the average velocity of the water flow. Due to the short distance between the neutron generator and the pipe the activity in the pipe becomes highly inhomogeneous. The transport and mixing of the activity were simulated using colour which was injected into the flow. It was found that the inhomogeneous activity distribution must be taken into account if the precision of the measurements is to be improved. The shape of the background in PNA affects the shape and position of the time spectrum. The nature of the background has been determined using one detector upstream and one downstream of the neutron generator. The background was shown to be caused by 16 N. A method that subtracts the background from the PNA time spectrum was also developed

  14. Determination of permittivity of pulses and cereals using metamaterial split ring resonator

    Science.gov (United States)

    Chakyar, Sreedevi P.; Sikha Simon, K.; Murali, Aathira; Shanto T., A.; Andrews, Jolly; Joseph V., P.

    2017-06-01

    Relative permittivity of wide variety of pulses and cereals are precisely determined with the help of metamaterial Split Ring Resonator (SRR) operating at microwave frequencies using a simple extraction procedure. The unknown permittivity of food samples in powder form are evaluated from a calibration curve drawn between the dielectric constant of some standard samples and LC resonant frequency of SRR test probe with the sample placed over it. The experimental setup consists of SRR test probe arranged between transmitting and receiving probes connected to a vector network analyzer. Unknown relative permittivity of the sample is obtained by placing it on the SRR surface and is evaluated from the calibration curve which is found to be in good agreement with the expected standard values. The possible applications of this sensitive and easy technique are analyzed in the field of food preservation, quality checking, adulteration etc.

  15. Determination of antioxidant activity of spices and their active principles by differential pulse voltammetry.

    Science.gov (United States)

    Palma, Alberto; Ruiz Montoya, Mercedes; Arteaga, Jesús F; Rodríguez Mellado, Jose M

    2014-01-22

    The anodic oxidation of mercury in the presence of hydrogen peroxide in differential pulse voltammetry (DPV) was used to determine the antioxidant (AO) character of radical scavengers. Hydroperoxide radical is formed at the potentials of the oxidation peak on mercury electrodes, such radical reacting with the antioxidants in different extension. The parameter C10 (antioxidant concentration at which the peak area decreases by 10%) is used to measure the scavenging activity of the individual antioxidants. To establish the scavenging activity of antioxidant mixtures as a whole, the parameter, μ10 as the reverse of V10, V10 being the volume necessary to decrease the peak area in DPV by 10%, was selected. Higher μ10 values correspond to higher scavenging activity. The studies have been extended to aqueous extracts of some species. The results may be useful in explaining the effect of spices in vitro and in vivo studies.

  16. Singular Value Decomposition Method to Determine Distance Distributions in Pulsed Dipolar Electron Spin Resonance.

    Science.gov (United States)

    Srivastava, Madhur; Freed, Jack H

    2017-11-16

    Regularization is often utilized to elicit the desired physical results from experimental data. The recent development of a denoising procedure yielding about 2 orders of magnitude in improvement in SNR obviates the need for regularization, which achieves a compromise between canceling effects of noise and obtaining an estimate of the desired physical results. We show how singular value decomposition (SVD) can be employed directly on the denoised data, using pulse dipolar electron spin resonance experiments as an example. Such experiments are useful in measuring distances and their distributions, P(r) between spin labels on proteins. In noise-free model cases exact results are obtained, but even a small amount of noise (e.g., SNR = 850 after denoising) corrupts the solution. We develop criteria that precisely determine an optimum approximate solution, which can readily be automated. This method is applicable to any signal that is currently processed with regularization of its SVD analysis.

  17. Determination of the X, Y coordinates of a pulsed ultrasonic source of signals

    International Nuclear Information System (INIS)

    Sokolov, B.V.; Shemyakin, V.V.

    1975-01-01

    A range of problems in predicting the emergency state of large-scale vessel housings are determined for subsequent solution involving acoustic emission phenomena. The authors specify the position of a given problem and present substantial grounds for selecting the minimum number of group signal receivers for unambiguous calculation of the location of the source. Relationships are obtained between X, Y - the coordinates of the pulse signal source - and experimentally measured time differences in recording of signals by group receivers. A criterion is given for selecting the true signal group combination when the receivers simultaneously record waves from several sources. Specific suggestions are made regarding the experimental information to be stored in a central computer for subsequent processing [ru

  18. Separation and determination of alditols and sugars by high-pH anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Andersen, Rikke; Sørensen, A.

    2000-01-01

    Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic-pulsed a......Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic......-pulsed amperometric detection (HPAEC-PAD) method that determines all the polyols used as food additives in food products and the most commonly found mono- and disaccharides on a routine basis. The linearity, repeatability, internal reproducibility and accuracy are described. The applicability of the method has been...

  19. Determination of alpha-naphthol by an oscillating chemical reaction using the analyte pulse perturbation technique

    International Nuclear Information System (INIS)

    Yang Wu; Sun Kanjun; Lv Weilian; Bo Lili; He Xiaoyan; Suo Nan; Gao Jinzhang

    2005-01-01

    An analytical method for the determination of alpha-naphthol (α-NP) is proposed by the sequential perturbation caused by different amounts of alpha-naphthol on the oscillating chemical system involving the Cu(II)-catalyzed oscillating reaction between hydrogen peroxide and sodium thiocyanate in an alkaline medium with the aid of continuous-flow stirred tank reactor (CSTR). The method relies on the linear relationship between the changes in the oscillation amplitude of the chemical system and the concentration of alpha-naphthol. The use of the analyte pulse perturbation technique permits sequential determinations in the same oscillating system owing to the expeditiousness with which the steady state is regained after each perturbation. The calibration curve obeys a linear equation very well when the concentration of alpha-naphthol is over the range 0.034-530 umol/L (r = 0.9991). Influences of temperature, injection points, flow rate and reaction variables on the oscillating system are investigated in detail and the possible mechanism of action of alpha-naphthol to the chemical oscillating system is also discussed. The method has been successfully used for the determination of α-naphthol in carbaryl hydrolysates

  20. Analysis of gases by a pulsed voltammetric sensor and the electrochemistry of high T[sub c] superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Rochani, S.

    1991-01-01

    This thesis is presented in two parts: Studies of gas sensing probes and the electrochemistry of superconductors. A Clark type polarographic oxygen sensor was used to analyze oxygen, hydrogen, chlorine, sulphur dioxide and nitrogen dioxide. A pulsed potential was applied driven by an IBM/XT compatible microcomputer with a 12 bit A-D/D-A card. In a series of experiments for each gas singly, and then mixtures, the probe was calibrated at different concentrations of gas dissolved in water at different times during the pulse to observe the optimum measurement. In the case of oxygen for a 20 s pulse at [minus]0.65 V between a platinum and silver/silver chloride, the optimum calibration was obtained between 2 and 4 s with a detection limit of 0.27 ppm oxygen. Hydrogen was determined at +0.60 V with a 50 s pulse and optimum range 3 to 4 s and detection limit 0.02 ppm. Chlorine was reduced at 0 V and optimally detected after 2 s of a 20 s pulse with a detection limit of 3 ppm. A mixture of hydrogen and oxygen was analyzed without mutual interference by a train of pulses at [minus]0.65, 0, +0.60 V or [minus]0.65, +0.60 V. For sulphur dioxide, a new probe was constructed with a separate reference, working and auxillary electrodes to overcome the formation of silver sulphide at the auxillary electrode. A preliminary study of nitrogen dioxide was done by observing the oxidation and reduction current at different applied voltages. Samples of each of the room temperature superconductors YBa[sub 2]Cu[sub 3]O[sub 7[minus][sigma

  1. Magnesium analysis. Determination of 5 elements by impulse polarography

    International Nuclear Information System (INIS)

    Anon.

    Determination of cadmium, copper, nickel, lead and zinc in magnesium used in magnesiothermics. The process is as follow: magnesium dissolution in hydrochloric acid, neutralisation by ammonia, addition of ammonium chloride and citric acid, ammonia is added until pH8. Addition of pyridine, polarographic determination of zinc and then of cadmium and copper [fr

  2. Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure.

    Science.gov (United States)

    Roth, Sebastian; Fox, Henrik; Fuchs, Uwe; Schulz, Uwe; Costard-Jäckle, Angelika; Gummert, Jan F; Horstkotte, Dieter; Oldenburg, Olaf; Bitter, Thomas

    2018-05-01

    Determination of cardiac output (CO) is essential in diagnosis and management of heart failure (HF). The gold standard to obtain CO is invasive assessment via thermodilution (TD). Noninvasive pulse contour analysis (NPCA) is supposed as a new method of CO determination. However, a validation of this method in HF is pending and performed in the present study. Patients with chronic-stable HF and reduced left ventricular ejection fraction (LVEF ≤ 45%; HF-REF) underwent right heart catheterization including TD. NPCA using the CNAP Monitor (V5.2.14, CNSystems Medizintechnik AG) was performed simultaneously. Three standardized TD measurements were compared with simultaneous auto-calibrated NPCA CO measurements. In total, 84 consecutive HF-REF patients were enrolled prospectively in this study. In 4 patients (5%), TD was not successful and for 22 patients (26%, 18 with left ventricular assist device), no NPCA signal could be obtained. For the remaining 58 patients, Bland-Altman analysis revealed a mean bias of + 1.92 L/min (limits of agreement ± 2.28 L/min, percentage error 47.4%) for CO. With decreasing cardiac index, as determined by the gold standard of TD, there was an increasing gap between CO values obtained by TD and NPCA (r = - 0.75, p TD-CI classified 52 (90%) patients to have a reduced CI (REF patients, auto-calibrated NPCA systematically overestimates CO with decrease in cardiac function. Therefore, to date, NPCA cannot be recommended in this cohort.

  3. Determining the water use of rambutan and longkong during phenological development by heat-pulse method

    Directory of Open Access Journals (Sweden)

    Sdoodee, S.

    2003-01-01

    Full Text Available The water use of two species of tropical fruit trees: rambutan (Nephelium lappaceum and longkong (Aglaia dookkoo Griff. were investigated by heat-pulse method. The sapflow rate of both species were determined during phenological development. An experiment was established at Prince of Songkla University, Songkhla Province. Characteristics of sapwood in each species and optimum depth for probe implanting on the trunk were investigated. During the measurement period, diurnal changes of photon flux density, leaf water potential and stomatal conductance were recorded. It was found that sapwood of rambutan and longkong were homogeneous. An appropriate probe depth to implant on the trunk was 25 mm from bark. It was found that diurnal changes of sapflow rates of each species varied with the changes of radiation, leaf water potential and stomata conductance. The results of measurement showed that water use decreased at pre-flowering stage, and fruit maturity stage. In rambutan, water use increased during vegetative growth stage followed by flowering stage. The marked increase of water use in rambutan was during fruit development. In longkong, water use increased at the flowering stage followed by vegetative growth stage, and the peak of water use was during fruit development.

  4. Determination of etching parameters for pulsed XeF2 etching of silicon using chamber pressure data

    Science.gov (United States)

    Sarkar, Dipta; Baboly, M. G.; Elahi, M. M.; Abbas, K.; Butner, J.; Piñon, D.; Ward, T. L.; Hieber, Tyler; Schuberth, Austin; Leseman, Z. C.

    2018-04-01

    A technique is presented for determination of the depletion of the etchant, etched depth, and instantaneous etch rate for Si etching with XeF2 in a pulsed etching system in real time. The only experimental data required is the pressure data collected temporally. Coupling the pressure data with the knowledge of the chemical reactions allows for the determination of the etching parameters of interest. Using this technique, it is revealed that pulsed etching processes are nonlinear, with the initial etch rate being the highest and monotonically decreasing as the etchant is depleted. With the pulsed etching system introduced in this paper, the highest instantaneous etch rate of silicon was recorded to be 19.5 µm min-1 for an initial pressure of 1.2 Torr for XeF2. Additionally, the same data is used to determine the rate constant for the reaction of XeF2 with Si; the reaction is determined to be second order in nature. The effect of varying the exposed surface area of Si as well as the effect that pressure has on the instantaneous etch rate as a function of time is shown applying the same technique. As a proof of concept, an AlN resonator is released using XeF2 pulses to remove a sacrificial poly-Si layer.

  5. Polarographic study of the Cu(II)/Cu(I) system in the presence of 1-ascorbic acid and 0,1 M ClK

    International Nuclear Information System (INIS)

    Alonso Lopez, J.

    1969-01-01

    While studying the catalytic effect of Cu ↓ 2 ions on the oxidation process of 1-ascorbic acid, it has been observed that, in a 0,1 M solution of K1 at a pH 6 to 7, the above acid gives rise in the presence of Cu ↓ 2 ions to a polarographic wave of half-wave potential of -0,41 V (vs. S.C.E.). (Author) 14 refs

  6. Determination of antimony trioxide in fire-retardant conveyor belts

    Energy Technology Data Exchange (ETDEWEB)

    Rytych-Witwicka, B.; Szmyd, E.

    1976-12-01

    Two methods for the determination of antimony trioxide in rubber and pvc are described. One is a colorimetric method based on the reaction of antimony with rhodamine B; the other is a polarographic method. The results of the two methods show a satisfactory consistency and the methods themselves appear rapid and effective.

  7. The simplest equivalent circuit of a pulsed dielectric barrier discharge and the determination of the gas gap charge transfer

    Science.gov (United States)

    Pipa, A. V.; Koskulics, J.; Brandenburg, R.; Hoder, T.

    2012-11-01

    The concept of the simplest equivalent circuit for a dielectric barrier discharge (DBD) is critically reviewed. It is shown that the approach is consistent with experimental data measured either in large-scale sinusoidal-voltage driven or miniature pulse-voltage driven DBDs. An expression for the charge transferred through the gas gap q(t) is obtained with an accurate account for the displacement current and the values of DBD reactor capacitance. This enables (i) the significant reduction of experimental error in the determination of q(t) in pulsed DBDs, (ii) the verification of the classical electrical theory of ozonizers about maximal transferred charge qmax, and (iii) the development of a graphical method for the determination of qmax from charge-voltage characteristics (Q-V plots, often referred as Lissajous figures) measured under pulsed excitation. The method of graphical presentation of qmax is demonstrated with an example of a Q-V plot measured under pulsed excitation. The relations between the discharge current jR(t), the transferred charge q(t), and the measurable parameters are presented in new forms, which enable the qualitative interpretation of the measured current and voltage waveforms without the knowledge about the value of the dielectric barrier capacitance Cd. Whereas for quantitative evaluation of electrical measurements, the accurate estimation of the Cd is important.

  8. The simplest equivalent circuit of a pulsed dielectric barrier discharge and the determination of the gas gap charge transfer

    International Nuclear Information System (INIS)

    Pipa, A. V.; Brandenburg, R.; Hoder, T.; Koskulics, J.

    2012-01-01

    The concept of the simplest equivalent circuit for a dielectric barrier discharge (DBD) is critically reviewed. It is shown that the approach is consistent with experimental data measured either in large-scale sinusoidal-voltage driven or miniature pulse-voltage driven DBDs. An expression for the charge transferred through the gas gap q(t) is obtained with an accurate account for the displacement current and the values of DBD reactor capacitance. This enables (i) the significant reduction of experimental error in the determination of q(t) in pulsed DBDs, (ii) the verification of the classical electrical theory of ozonizers about maximal transferred charge q max , and (iii) the development of a graphical method for the determination of q max from charge-voltage characteristics (Q-V plots, often referred as Lissajous figures) measured under pulsed excitation. The method of graphical presentation of q max is demonstrated with an example of a Q-V plot measured under pulsed excitation. The relations between the discharge current j R (t), the transferred charge q(t), and the measurable parameters are presented in new forms, which enable the qualitative interpretation of the measured current and voltage waveforms without the knowledge about the value of the dielectric barrier capacitance C d . Whereas for quantitative evaluation of electrical measurements, the accurate estimation of the C d is important.

  9. Laboratory ultrasonic pulse velocity logging for determination of elastic properties from rock core

    Science.gov (United States)

    Blacklock, Natalie Erin

    During the development of deep underground excavations spalling and rockbursting have been recognized as significant mechanisms of violent brittle failure. In order to predict whether violent brittle failure will occur, it is important to identify the location of stiffness transitions that are associated with geologic structure. One approach to identify the effect of geologic structures is to apply borehole geophysical tools ahead of the tunnel advance. Stiffness transitions can be identified using mechanical property analysis surveys that combine acoustic velocity and density data to calculate acoustic estimates of elastic moduli. However, logistical concerns arise since the approach must be conducted at the advancing tunnel face. As a result, borehole mechanical property analyses are rarely used. Within this context, laboratory ultrasonic pulse velocity testing has been proposed as a potential alternative to borehole mechanical property analysis since moving the analysis to the laboratory would remove logistical constraints and improve safety for the evaluators. In addition to the traditional method of conducting velocity testing along the core axis, two new methodologies for point-focused testing were developed across the core diameter, and indirectly along intact lengths of drill core. The indirect test procedure was implemented in a continuous ultrasonic velocity test program along 573m of drill core to identify key geologic structures that generated transitions in ultrasonic elastic moduli. The test program was successful at identifying the location of geologic contacts, igneous intrusions, faults and shear structures. Ultrasonic values of Young's modulus and bulk modulus were determined at locations of significant velocity transitions to examine the potential for energy storage and energy release. Comparison of results from different ultrasonic velocity test configurations determined that the indirect test configuration provided underestimates for values of

  10. One-day pulsed-field gel electrophoresis protocol for rapid determination of emetic Bacillus cereus isolates.

    Science.gov (United States)

    Kaminska, Paulina S; Fiedoruk, Krzysztof; Jankowska, Dominika; Mahillon, Jacques; Nowosad, Karol; Drewicka, Ewa; Zambrzycka, Monika; Swiecicka, Izabela

    2015-04-01

    Bacillus cereus, the Gram-positive and spore-forming ubiquitous bacterium, may cause emesis as the result of food intoxication with cereulide, a heat-stable emetic toxin. Rapid determination of cereulide-positive B. cereus isolates is of highest importance due to consequences of this intoxication for human health and life. Here we present a 1-day pulsed-field gel electrophoresis for emetic B. cereus isolates, which allows rapid and efficient determination of their genomic relatedness and helps determining the source of intoxication in case of outbreaks caused by these bacilli. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Determination of oxidation products in radiolysis of halophenols with pulse radiolysis, hplc, and ion chromatography

    International Nuclear Information System (INIS)

    Ye, M.; Schuler, R.H.

    1990-01-01

    This paper reports on hydroxyl radicals that react with halogen substituted phenols by several different ways. One is addition of OH radicals to the aromatic ring, which is followed by elimination of hydrogen halide, H 2 O or H - . The positions of OH radicals attack are dependent on the nature of the halogen which affects the electronic distribution in the ring. The oxidation of fluorophenols, chlorophenols and bromophenols with hydroxyl radicals in N 2 O saturated solution has been investigated with pulse radiolysis and γ-irradiation experiments. The intermediates of the reactions were studied by pulse radiolysis. The products created in the γ-irradiation of aqueous solutions of halophenols were analyzed by ion chromatography and high performance liquid chromatography (HPLC). With the combination of time-resolved and steady-state experiments a complete and detailed description of radiolytic oxidation of halophenols by hydroxyl radicals was obtained

  12. Determination of elemental composition of coffee using UV-pulsed laser induced breakdown spectroscopy

    International Nuclear Information System (INIS)

    Gondal, M. A.; Baig, Umair; Dastageer, M. A.; Sarwar, Mohsin

    2016-01-01

    A detection system based on laser induced breakdown spectroscopy (LIBS) was built using 266 nm wavelength pulsed laser from the fourth harmonic of Nd:YAG laser, 500 mm spectrograph and gated ICCD camera with built-in delay generator. The LIBS system was used to study the elemental composition in coffee available in the local market of Saudi Arabia for the detection of elements in coffee samples. The LIBS spectrum of coffee sample revealed the presence magnesium, calcium, aluminum, copper, sodium, barium, bromine, cobalt, chromium, cerium manganese and molybdenum. Atomic transition line of sodium is used to study the parametric dependence of LIBS signal. The study of the dependence of LIBS signal on the laser pulse energy is proven to be linear and the dependence of LIBS signal on the time delay between the excitation and data acquisition showed a typical increase, a peak value and a decrease with the optimum excitation – acquisition delay at 400 ns.

  13. Determination of Heritage SSME Pogo Suppressor Resistance and Inertance from Waterflow Pulse Testing

    Science.gov (United States)

    McDougal, Chris; Eberhart, Chad; Lee, Erik

    2016-01-01

    Waterflow tests of a heritage Space Shuttle Main Engine pogo suppressor were performed to experimentally quantify the resistance and inertance provided by the suppressor. Measurements of dynamic pressure and flow rate in response to pulsing flow were made throughout the test loop. A unique system identification methodology combined all sensor measurements with a one-dimensional perturbational flow model of the complete water flow loop to spatially translate physical measurements to the device under test. Multiple techniques were then employed to extract the effective resistance and inertance for the pogo suppressor. Parameters such as steady flow rate, perturbational flow rate magnitude, and pulse frequency were investigated to assess their influence on the behavior of the pogo suppressor dynamic response. These results support validation of the RS-25 pogo suppressor performance for use on the Space Launch System Core Stage.

  14. Pulsed neutron determination of anisotropic diffusion constants in multi-layered slabs

    International Nuclear Information System (INIS)

    Sri Ram, K.

    1978-01-01

    Anisotropic neutron diffusion parameters for graphite and plexiglas slab assemblies were calculated using one-dimensional discrete ordinates code ANISN, and also Case's eigenfunction expansion technique as suggested by Leonard. These calculated values were checked with the pulsed neutron experimental results as well as simple diffusion theory calculations of Spinrad. Relatively little experimental work has been done with heterogeneous assemblies which do not contain voids. The present comparison shows that the experimental results agree well with transport theory calculations. It appears from the results and inter-comparison of this work in simple geometries, that the pulsed neutron method can yield accurate experimental anisotropic diffusion constants, and can therefore be applied to more complicated geometries which may be difficult to calculate. (author)

  15. Determination of elemental composition of coffee using UV-pulsed laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gondal, M. A., E-mail: magondal@kfupm.edu.sa; Baig, Umair; Dastageer, M. A.; Sarwar, Mohsin [Laser Research Group, Physics Department, King Fahd University of Petroleum and Minerals, P.O Box 5047, Dhahran 31261 (Saudi Arabia)

    2016-06-10

    A detection system based on laser induced breakdown spectroscopy (LIBS) was built using 266 nm wavelength pulsed laser from the fourth harmonic of Nd:YAG laser, 500 mm spectrograph and gated ICCD camera with built-in delay generator. The LIBS system was used to study the elemental composition in coffee available in the local market of Saudi Arabia for the detection of elements in coffee samples. The LIBS spectrum of coffee sample revealed the presence magnesium, calcium, aluminum, copper, sodium, barium, bromine, cobalt, chromium, cerium manganese and molybdenum. Atomic transition line of sodium is used to study the parametric dependence of LIBS signal. The study of the dependence of LIBS signal on the laser pulse energy is proven to be linear and the dependence of LIBS signal on the time delay between the excitation and data acquisition showed a typical increase, a peak value and a decrease with the optimum excitation – acquisition delay at 400 ns.

  16. Genetic heterogeneity of Campylobacter concisus determined by pulsed field gel electrophoresis-based macrorestriction profiling

    DEFF Research Database (Denmark)

    Matsheka, M.I.; Elisha, B.G.; Lastovica, A.L.

    2002-01-01

    1 for pulsed field gel electrophoresis-based genotyping. Subsequently, 53 strains of C concisus, principally from cases of diarrhoea in children, were examined. Fifty-one distinct patterns were obtained, indicating the high discriminatory potential of the method. Patterns comprised between one...... comprised of several genomospecies. The pulsed field gel electrophoresis typing method described here has considerable potential for molecular epidemiological studies of C concisus and may be a useful adjunctive method for helping to resolve key taxonomic issues for this species....... and 14 restriction fragments, with type and reference strains of two well-defined genomospecies of oral and faecal origin containing six and 12 fragments respectively. Our results show that C concisus is genetically diverse and suggest the species as currently defined to be a taxonomic continuum...

  17. Determination of thermal and physical properties of port-wine stain lesions using pulsed photothermal radiometry

    Science.gov (United States)

    Nelson, J. Stuart; Jacques, Steven L.; Wright, William H.

    1992-06-01

    A method for quantitative characterization of port wine stain (PWS) is presented. Pulsed photothermal radiometry (PPTR) uses a non-invasive infrared radiometry system to measure changes in surface temperature induced by pulsed radiation. When a pulsed laser is used to irradiate a PWS, an initial temperature jump (T-jump) is seen due to the heating of the epidermis as a result of melanin absorption. Subsequently, heat generated in the subsurface blood vessels due to hemoglobin absorption is detected by PPTR as a delayed thermal wave as the heat diffuses toward the skin surface. The time delay and magnitude of the delayed PPTR signal indicate the depth and thickness of the PWS. In this report, we present an initial clinical study of PPTR measurements on PWS patients. Computer simulations of various classes of PWS illustrate how the PPTR signal depends on the concentration of epidermal melanin, and depth and thickness of the PWS. The goal of this research is to provide a means of characterizing PWS before initiating therapy, guiding laser dosimetry, and advising the patient as to the time course and efficacy of the planned protocol.

  18. Method of analysis to determine subcritical reactivity from the pulsed neutron experiment

    International Nuclear Information System (INIS)

    Parks, P.B.

    1975-06-01

    The published methods for the deduction of reactivity from pulsed neutron experiments on subcritical reactors are reviewed. Each method is categorized as inherently yielding a result that is either spatially independent or spatially dependent. The spatially independent results are formally identical with the static reactivity; the result does not depend, in principle, on the location of either the pulsed neutron source or the neutron detector during data collection. The spatially dependent results only approximate the static reactivity; the results are affected, in varying degrees, by the locations of the source and detector. Among the techniques yielding spatially independent results are the Space-Time method of Parks and Stewart and the Inhour method of Preskitt et al. Spatially dependent results are obtained with the Sjoestrand, Gozani, and Garelis-Russell methods which are examined with and without the kinetic distortion corrections given by Becker and Quisenberry. Intercomparisons of all methods are made with reference to pulsed neutron experiments on both unreflected and reflected reactors. Recommendations are made concerning the best choice of method under the various experimental conditions that are likely to be encountered. 14 references. (U.S.)

  19. Determination and identification of naturally occurring decay series using milli-second order pulse time interval analysis (TIA)

    International Nuclear Information System (INIS)

    Hashimoto, T.; Sanada, Y.; Uezu, Y.

    2003-01-01

    A delayed coincidence method, called a time interval analysis (TIA) method, has been successfully applied to selective determination of the correlated α-α decay events in millisecond order life-time. A main decay process applicable to TIA-treatment is 220 Rn → 216 Po(T 1/2 :145ms) → {Th-series}. The TIA is fundamentally based on the difference of time interval distribution between non-correlated decay events and other events such as background or random events when they were compiled the time interval data within a fixed time (for example, a tenth of concerned half lives). The sensitivity of the TIA-analysis due to correlated α-α decay events could be subsequently improved in respect of background elimination using the pulse shape discrimination technique (PSD with PERALS counter) to reject β/γ-pulses, purging of nitrogen gas into extra scintillator, and applying solvent extraction of Ra. (author)

  20. Determination of chlorine, sulfur and carbon in reinforced concrete structures by double-pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Labutin, Timur A.; Popov, Andrey M.; Zaytsev, Sergey M.; Zorov, Nikita B.; Belkov, Mikhail V.; Kiris, Vasilii V.; Raikov, Sergey N.

    2014-09-01

    Accurate and reliable quantitative determination of non-metal corrosion agents in concrete is still an actual task of analytical use of LIBS. Two double-pulse LIBS systems were tested as a tool for the determination of chlorine, sulfur and carbon in concretes. Both systems had collinear configuration; a laboratory setup was equipped with an ICCD and two lasers (355/532 nm + 540 nm), but a CCD was a detector for a mobile system with one laser (1064 nm). Analytical lines of Cl I at 837.59 nm, S I at 921 nm and C I at 247.86 nm were used to plot calibration curves. Optimal interpulse delays for the laboratory setup were 4 μs for chlorine and 2.8 μs for carbon, while an interpulse delay of 2 μs was optimal for chlorine and sulfur determination with the mobile system. We suggested the normalization of the Cl I line at 837.59 nm to the Mg II line at 279.08 nm (visible at 837.23 nm in the third order) to compensate for pulse-to-pulse fluctuations of chlorine lines. It provided the decrease of the detection limit of chlorine from 400 ppm to 50 ppm. Therefore, we reported that LIBS can be used to determine main corrosive active substances under ambient conditions in concrete below critical threshold values. Moreover, the application of the mobile system for in-situ qualitative assessment of corrosion way of a steel cage of a swimming pool dome was also demonstrated. It was found that chloride corrosion due to the disinfection of water was the main way for corrosion of the open part steel and the steel rebar inside the concrete.

  1. Determination of residual oil saturation from time-lapse pulsed neutron capture logs in a large sandstone reservoir

    International Nuclear Information System (INIS)

    Syed, E.V.; Salaita, G.N.; McCaffery, F.G.

    1991-01-01

    Cased hole logging with pulsed neutron tools finds extensive use for identifying zones of water breakthrough and monitoring oil-water contacts in oil reservoirs being depleted by waterflooding or natural water drive. Results of such surveys then find direct use for planning recompletions and water shutoff treatments. Pulsed neutron capture (PNC) logs are useful for estimating water saturation changes behind casing in the presence of a constant, high-salinity environment. PNC log surveys run at different times, i.e., in a time-lapse mode, are particularly amenable to quantitative analysis. The combined use of the original open hole and PNC time-lapse log information can then provide information on remaining or residual oil saturations in a reservoir. This paper reports analyses of historical pulsed neutron capture log data to assess residual oil saturation in naturally water-swept zones for selected wells from a large sandstone reservoir in the Middle East. Quantitative determination of oil saturations was aided by PNC log information obtained from a series of tests conducted in a new well in the same field

  2. Determination of base-line levels of trace amounts in pulses and spices using neutron activation technique

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I.; Qureshi, I.H.

    1993-01-01

    It has been established that essential trace elements are vitally important for biochemical systems, whereas toxic elements if present in relatively higher amounts adversely affect these systems. Trace elements reach the human body mainly through foodstuffs. The different articles contain varying amount of toxic and essential elements. It is therefore necessary to asses the adequacy and safety of the diet by determining the base-line levels of these elements. In continuation of our previous work, some varieties of pulses and spices were analyzed using neutron activation technique. Among the four varieties of pulses lentil (lens esculenta) was found to contain higher amounts of essential elements and lower amounts of toxic elements. The daily intake of essential and toxic elements through pulses was estimated and compared with the suggested values. The estimated intake of essential elements is adequate and that of toxic elements is well below the tolerance limit. In spices cumin and caraway seeds were found to contain relatively higher amounts of essential as well as toxic elements. The studies showed that food spices were additional source of trace element intake. (author)

  3. Continued Evaluation of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations - 12518

    Energy Technology Data Exchange (ETDEWEB)

    Denslow, Kayte M.; Bontha, Jagannadha R.; Adkins, Harold E.; Jenks, Jeromy W.J.; Burns, Carolyn A.; Schonewill, Philip P.; Hopkins, Derek F. [Pacific Northwest National Laboratory, Richland, Washington 99354 (United States); Thien, Michael G.; Wooley, Theodore A. [Washington River Protection Solutions, Richland, Washington 99354 (United States)

    2012-07-01

    The delivery of Hanford double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be governed by specific Waste Acceptance Criteria that are identified in ICD 19 - Interface Control Document for Waste Feed. Waste must be certified as acceptable before it can be delivered to the WTP. The fluid transfer velocity at which solid particulate deposition occurs in waste slurry transport piping (critical velocity) is a key waste parameter that must be accurately characterized to determine if the waste is acceptable for transfer to the WTP. In 2010 Washington River Protection Solutions and the Pacific Northwest National Laboratory began evaluating the ultrasonic PulseEcho instrument to accurately identify critical velocities in a horizontal slurry transport pipeline for slurries containing particles with a mean particle diameter of >50 micrometers. In 2011 the PulseEcho instrument was further evaluated to identify critical velocities for slurries containing fast-settling, high-density particles with a mean particle diameter of <15 micrometers. This two-year evaluation has demonstrated the ability of the ultrasonic PulseEcho instrument to detect the onset of critical velocity for a broad range of physical and rheological slurry properties that are likely encountered during the waste feed transfer operations between the Hanford tank farms and the WTP. (authors)

  4. Determination of chlorine, sulfur and carbon in reinforced concrete structures by double-pulse laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Labutin, Timur A., E-mail: timurla@laser.chem.msu.ru [Lomonosov Moscow State University, Department of Chemistry, Leninskie Gory 1-3, Moscow 119991 (Russian Federation); Popov, Andrey M.; Zaytsev, Sergey M.; Zorov, Nikita B. [Lomonosov Moscow State University, Department of Chemistry, Leninskie Gory 1-3, Moscow 119991 (Russian Federation); Belkov, Mikhail V.; Kiris, Vasilii V.; Raikov, Sergey N. [B.I. Stepanov Institute of Physics, Nezavisimosti Ave. 68, Minsk 220072 (Belarus)

    2014-09-01

    Accurate and reliable quantitative determination of non-metal corrosion agents in concrete is still an actual task of analytical use of LIBS. Two double-pulse LIBS systems were tested as a tool for the determination of chlorine, sulfur and carbon in concretes. Both systems had collinear configuration; a laboratory setup was equipped with an ICCD and two lasers (355/532 nm + 540 nm), but a CCD was a detector for a mobile system with one laser (1064 nm). Analytical lines of Cl I at 837.59 nm, S I at 921 nm and C I at 247.86 nm were used to plot calibration curves. Optimal interpulse delays for the laboratory setup were 4 μs for chlorine and 2.8 μs for carbon, while an interpulse delay of 2 μs was optimal for chlorine and sulfur determination with the mobile system. We suggested the normalization of the Cl I line at 837.59 nm to the Mg II line at 279.08 nm (visible at 837.23 nm in the third order) to compensate for pulse-to-pulse fluctuations of chlorine lines. It provided the decrease of the detection limit of chlorine from 400 ppm to 50 ppm. Therefore, we reported that LIBS can be used to determine main corrosive active substances under ambient conditions in concrete below critical threshold values. Moreover, the application of the mobile system for in-situ qualitative assessment of corrosion way of a steel cage of a swimming pool dome was also demonstrated. It was found that chloride corrosion due to the disinfection of water was the main way for corrosion of the open part steel and the steel rebar inside the concrete. - Highlights: • Determination of chlorine, sulfur and carbon in concrete in the air. • Comparison of mobile and laboratory LIBS systems. • LOD by double-pulse LIBS under ambient conditions: for sulfur 1500 ppm, for chlorine — 50 ppm. • Background level of carbon content in concrete is about 0.27% wt.

  5. Pulsed Neutron log application in accurate fluid contact determination and remedial action planning

    International Nuclear Information System (INIS)

    Kalu, I.; Mukerji, P.

    2002-01-01

    A common application of pulsed neutron logging in the Niger Delta is saturation monitoring when run in carbon-oxygen (CO) mode. Recently, one such log was run across a reservoir to confirm the position of the oil-water contact on a well that was producing at very high water cut on the short string of a dual string producer. Material balance calculations had predicted an oil-water contact about 5ft from the deepest perforations and so a water shut-off operation had been planned. The interpreted log however showed that the OWC was about 30ft from the perforation and it also showed fluid movement in the borehole in front of the perforations. A production log was subsequently run which identified a tubing leak and confirmed the crossflow of water from the long string into the short string detected on the pulsed neutron log. The proposed water shut-off treatment was aborted based on the interpretation and resulted in substantial savings

  6. Developments in Pulsed Neutron Activation for Determination of Water Flow in Pipes

    CERN Document Server

    Mattsson, H

    2003-01-01

    In PNA (pulsed neutron activation) it is important that the measured data can be related to the total mass flow. In this thesis two fundamental problems of the measurement technique and data treatment have been investigated: transport/mixing and background radiation. The principle of PNA is to introduce a radioactive substance into a pipe by bombarding fluid in the pipe with neutron pulses. The fluid in the pipe is activated and subsequently transported and mixed with the flow. Gamma radiation emitted from the activity is measured with one or two detectors downstream from the activation point. The time-resolved signal from the detectors is used to calculate the average velocity of the water flow. Due to the short distance between the neutron generator and the pipe the activity in the pipe becomes highly inhomogeneous. The transport and mixing of the activity were simulated using colour which was injected into the flow. It was found that the inhomogeneous activity distribution must be taken into account if the...

  7. Polarographic investigation of complexing kinetics of polyacrylate anions with cadmium ions. Polyarograficheskoe issledovanie kinetiki kompleksoobrazovaniya poliakrilat-anionov s ionami kadmiya

    Energy Technology Data Exchange (ETDEWEB)

    Avlyanov, Zh K; Kabanov, N M; Zezin, A B; Askarov, M A

    1990-01-01

    The processes which occur during the reduction of cadmium ions from polymer-metallic complexes (PMC) are studied for the purposes of polarographic investigation of complexing kinetics of polyacrylate anions (PAA) of different molecular masses with cadmium ions in KCl aqueous solutions. An expression is derived for establishing semiwave potential. PMC formation and dissociation reduction rate constants are calculated. It is shown that intramolecular reorderings required for the formation of a two-coordinate complex proceed much slower as compared to the diffusion of free ions.

  8. The determination of reactivity at a compact core with low absorption reflector by means of the pulsed neutron method

    International Nuclear Information System (INIS)

    Hecker, R.; Drueke, V.; Ahmad, S.K.; Kacmary, S.; Paul, N.

    1976-09-01

    Pulsed measurements at a compact critical facility with low absorption reflector are described. By a number of such measurements at different points of the system a proper value for the reactivity can be determined, which allows a meaningful comparison with values calculated by static computer codes in spite of the presence of kinetic distortion in the system. A modified area ratio method is developed and applied to the measurements; furthermore a method is shown, which allows to suppress in this systems the kinetic distortion in the fundamental mode by application of special detectors. (orig.) [de

  9. Determination of adiabatic temperature change in MnFe(P,Ge) compounds with pulse-field method

    International Nuclear Information System (INIS)

    Trung, N T; Tegus, O; Cam Thanh, D T; Buschow, K H J; Brueck, E; Klaasse, J C P

    2010-01-01

    Fast magnetic measurements performed by means of a 20 T pulse-field magnet provide a good approach for directly monitoring the magnetocaloric effect of the MnFe(P,Ge) compounds. Based on the comparison of magnetization curves obtained either in an adiabatic or isothermal process, we propose that the method introduced by Levitin et al is applicable to determine the adiabatic temperature change for an equivalent field change in first-order magnetic transition materials. More strikingly, experimental results confirm that the first-order nature of the transition in MnFe(P,Ge) alloys is not a limiting factor to the operation frequency of a magnetic refrigerator.

  10. New spectrofluorometer with pulsed intensified photodiodes array for direct trace determination of actinides and lanthanides in solutions

    International Nuclear Information System (INIS)

    Decambox, P.; Kirsch, B.; Mauchien, P.; Moulin, C.

    1989-01-01

    Actinides and lanthanides in solution at very low level are determined by Time-Resolved Laser-Induced Spectrofluorometry (TRLIS) with pulsed intensified photodiodes array detection. Temporal resolution allows discrimination against short lifetime fluorescence and measurement of fluorescence lifetime in various matrices. The use of laser source leads to excitation selectivity and high sensitivity. Multichannel detection allows to cover the entire wavelength range of interest which leads to emission selectivity and rapidity. These different advantages are present in the newly commercialized spectrofluorometer FLUO 2001 together with specially analytical adapted software. The apparatus and performances obtained for several actinides and lanthanides are presented

  11. The Determination of Pesticidal and Non-Pesticidal Organotin Compounds by in situ Ethylation and Capillary Gas Chromatography with Pulsed Flame Photometric Detection

    Science.gov (United States)

    The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detect...

  12. The Determination of Pesticidal and Non-Pesticidal Organotin Compounds in Water Matrices by in situ Ethylation and Gas Chromatography with Pulsed Flame Photometric Detection

    Science.gov (United States)

    The concurrent determination of pesticidal and non-pesticidal organotin compounds in several water matrices, using a simultaneous in situ ethylation and liquid-liquid extraction followed by splitless injection mode capillary gas chromatography with pulsed flame photometric detect...

  13. Part I. Application of pulse polarography and pulse anodic stripping to the determination of selected heavy metals in natural waters. Part II. Application of controlled potential coulometric techniques to the determination of uranium

    International Nuclear Information System (INIS)

    Crosmun, S.T.

    1977-06-01

    The use of a thin mercury film wax-impregnated graphite electrode for the simultaneous determination of cadmium, lead and zinc in an acetate buffer by differential pulse anodic stripping voltammetry is described. Optimal instrumental parameters for maximum resolution and sensitivity for simultaneous analysis of these three elements in natural waters are discussed. The interference of copper with the determination of zinc is investigated in detail. An optimal mercury film thickness for this electrode is suggested. A method utilizing differential pulse polarography for the determination of chromium (VI) in natural water is described. Additions of 0.62 μg Cu(II) ml -1 and 0.55 μg Fe(III) ml -1 did not interfere with the determination of 0.050 μg Cr(VI) ml -1 . The natural water samples containing Cr(VI) were buffered to approximately pH 7 with 0.1 M ammonium acetate and 0.005 M ethylenediamine and analyzed. Natural water samples of chromium from 0.035 μg to 2.0 μg.ml -1 may be analyzed directly without further preparation. The detection limit is 0.010 μg.ml -1 . A novel, highly efficient cell with integral stirrer for controlled potential coulometry is described. This cell was used to demonstrate the feasibility of determining uranium (VI) by predictive coulometry. A PDP 8/I minicomputer was used to predict the coulometric endpoint with high accuracy within 2.5 minutes in a titration which normally takes about 10 minutes. This technique was shown to yield acceptable results even in the presence of an interfering phosphate matrix

  14. Theoretical determination of transit time locus curves for ultrasonic pulse echo testing - ALOK. Pt. 4

    International Nuclear Information System (INIS)

    Grohs, B.

    1983-01-01

    The ALOK-technique allows the simultaneous detection of flaws and their evaluation with respect to type, location and dimension by interpretation of the transit time behaviour during scanning of the reflector. The accuracy of information obtained by means of this technique can be further improved both during interference elimination and reconstruction owing to the ability of exact calculation of possible transit time locus curves of given reflectors. The mathematical solution of transit time locus curve calculations refers here to pulse echo testing in consideration of the refraction of sound on the forward wedge/test object - interface. The method of solving the problem is equivalent to the Fermat's principle in optics. (orig.) [de

  15. Determination of carbohydrates by high performance anion chromatography-pulsed amperometric detection in mushrooms.

    Science.gov (United States)

    Zhou, Shuai; Tang, Qingjiu; Luo, Xi; Xue, Jun-Jie; Liu, Yanfang; Yang, Yan; Zhang, Jingsong; Feng, Na

    2012-01-01

    A method of detecting carbohydrates (fucose, trehalose, mannitol, arabitol, mannose, glucose, galactose, fructose, and ribose) by high-performance anion chromatography-pulsed amperometric detection (HAPEC-PAD) was established. The conditions are: CarboPac MA1 column, NaOH as the eluent, temperature 30°C, Au working electrode, Ag/AgCl reference electrode, and flow rate 0.4 mL/min. These nine analytes, which yielded high resolution by this method, could be detected in 40 minutes. Mushrooms were tested and good precision, stability, and reproducibility were achieved. This method is suitable for mushroom samples and could support research and development on sugar and sugar alcohol, which contains special effects.

  16. Simulation of pulsed neutron activation for determination of water flow in pipes

    International Nuclear Information System (INIS)

    Mattsson, H.; Owrang, F.; Nordlund, A.

    2002-01-01

    The effect of the asymmetric distribution of activated water in PNA (pulsed neutron activation) measurements has been investigated experimentally by depositing a small amount of colour, simulating the activated water, in a transparent Plexiglas pipe. Based on the colour experiments, a semi-empirical model has been developed that describes the distribution of the activated water at different distances from the activation point. The model shows that the combination of inhomogeneous activation and a radial velocity profile makes the mean velocity of the activity lower than the mean velocity of the water. It can also be seen that the velocity of the activity increases as the distance from the activation point increases. The model has been compared with experimental values from PNA measurements and the measured mean velocity shows a similar dependence on the distance form the activation point. (orig.) [de

  17. [Application of three heat pulse technique-based methods to determine the stem sap flow].

    Science.gov (United States)

    Wang, Sheng; Fan, Jun

    2015-08-01

    It is of critical importance to acquire tree transpiration characters through sap flow methodology to understand tree water physiology, forest ecology and ecosystem water exchange. Tri-probe heat pulse sensors, which are widely utilized in soil thermal parameters and soil evaporation measurement, were applied to implement Salix matsudana sap flow density (Vs) measurements via heat-ratio method (HRM), T-Max method (T-Max) and single-probe heat pulse probe (SHPP) method, and comparative analysis was conducted with additional Grainer's thermal diffusion probes (TDP) measured results. The results showed that, it took about five weeks to reach a stable measurement stage after TPHP installation, Vs measured with three methods in the early stage after installation was 135%-220% higher than Vs in the stable measurement stage, and Vs estimated via HRM, T-Max and SHPP methods were significantly linearly correlated with Vs estimated via TDP method, with R2 of 0.93, 0.73 and 0.91, respectively, and R2 for Vs measured by SHPP and HRM reached 0.94. HRM had relatively higher precision in measuring low rates and reverse sap flow. SHPP method seemed to be very promising to measure sap flow for configuration simplicity and high measuring accuracy, whereas it couldn' t distinguish directions of flow. T-Max method had relatively higher error in sap flow measurement, and it couldn' t measure sap flow below 5 cm3 · cm(-2) · h(-1), thus this method could not be used alone, however it could measure thermal diffusivity for calculating sap flow when other methods were imposed. It was recommended to choose a proper method or a combination of several methods to measure stem sap flow, based on specific research purpose.

  18. Fieldable computer system for determining gamma-ray pulse-height distributions, flux spectra, and dose rates from Little Boy

    International Nuclear Information System (INIS)

    Moss, C.E.; Lucas, M.C.; Tisinger, E.W.; Hamm, M.E.

    1984-01-01

    Our system consists of a LeCroy 3500 data acquisition system with a built-in CAMAC crate and eight bismuth-germanate detectors 7.62 cm in diameter and 7.62 cm long. Gamma-ray pulse-height distributions are acquired simultaneously for up to eight positions. The system was very carefully calibrated and characterized from 0.1 to 8.3 MeV using gamma-ray spectra from a variety of radioactive sources. By fitting the pulse-height distributions from the sources with a function containing 17 parameters, we determined theoretical repsonse functions. We use these response functions to unfold the distributions to obtain flux spectra. A flux-to-dose-rate conversion curve based on the work of Dimbylow and Francis is then used to obtain dose rates. Direct use of measured spectra and flux-to-dose-rate curves to obtain dose rates avoids the errors that can arise from spectrum dependence in simple gamma-ray dosimeter instruments. We present some gamma-ray doses for the Little Boy assembly operated at low power. These results can be used to determine the exposures of the Hiroshima survivors and thus aid in the establishment of radation exposure limits for the nuclear industry

  19. A novel and practical approach for determination of the acoustic nonlinearity parameter using a pulse-echo method

    Science.gov (United States)

    Jeong, Hyunjo; Zhang, Shuzeng; Barnard, Dan; Li, Xiongbing

    2016-02-01

    Measurements of the acoustic nonlinearity parameter β are frequently made for early detection of damage in various materials. The practical implementation of the measurement technique has been limited to the through-transmission setup for determining the nonlinearity parameter of the second harmonic wave. In this work, a feasibility study is performed to assess the possibility of using pulse-echo methods in determining the nonlinearity parameter β of solids with a stress-free boundary. The multi-Gaussian beam model is developed based on the quasilinear theory of the KZK equation. Simulation results and discussion are presented for the reflected beam fields of the fundamental and second harmonic waves, the uncorrected β behavior and the properties of total correction that incorporate reflection, attenuation and diffraction effects.

  20. Plasma interactions determine the composition in pulsed laser deposited thin films

    Science.gov (United States)

    Chen, Jikun; Döbeli, Max; Stender, Dieter; Conder, Kazimierz; Wokaun, Alexander; Schneider, Christof W.; Lippert, Thomas

    2014-09-01

    Plasma chemistry and scattering strongly affect the congruent, elemental transfer during pulsed laser deposition of target metal species in an oxygen atmosphere. Studying the plasma properties of La0.6Sr0.4MnO3, we demonstrate for as grown La0.6Sr0.4MnO3-δ films that a congruent transfer of metallic species is achieved in two pressure windows: ˜10-3 mbar and ˜2 × 10-1 mbar. In the intermediate pressure range, La0.6Sr0.4MnO3-δ becomes cation deficient and simultaneously almost fully stoichiometric in oxygen. Important for thin film growth is the presence of negative atomic oxygen and under which conditions positive metal-oxygen ions are created in the plasma. This insight into the plasma chemistry shows why the pressure window to obtain films with a desired composition and crystalline structure is narrow and requires a careful adjustment of the process parameters.

  1. Plasma interactions determine the composition in pulsed laser deposited thin films

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jikun; Stender, Dieter; Conder, Kazimierz; Wokaun, Alexander; Schneider, Christof W.; Lippert, Thomas, E-mail: thomas.lippert@psi.ch [Paul Scherrer Institute, CH-5232 Villigen PSI (Switzerland); Döbeli, Max [Laboratory of Ion Beam Physics, ETH Zurich, CH-8093 Zurich (Switzerland)

    2014-09-15

    Plasma chemistry and scattering strongly affect the congruent, elemental transfer during pulsed laser deposition of target metal species in an oxygen atmosphere. Studying the plasma properties of La{sub 0.6}Sr{sub 0.4}MnO{sub 3}, we demonstrate for as grown La{sub 0.6}Sr{sub 0.4}MnO{sub 3-δ} films that a congruent transfer of metallic species is achieved in two pressure windows: ∼10{sup −3} mbar and ∼2 × 10{sup −1} mbar. In the intermediate pressure range, La{sub 0.6}Sr{sub 0.4}MnO{sub 3-δ} becomes cation deficient and simultaneously almost fully stoichiometric in oxygen. Important for thin film growth is the presence of negative atomic oxygen and under which conditions positive metal-oxygen ions are created in the plasma. This insight into the plasma chemistry shows why the pressure window to obtain films with a desired composition and crystalline structure is narrow and requires a careful adjustment of the process parameters.

  2. A standardized method to determine the concentration of extracellular vesicles using tunable resistive pulse sensing

    Directory of Open Access Journals (Sweden)

    Robert Vogel

    2016-09-01

    Full Text Available Background: Understanding the pathogenic role of extracellular vesicles (EVs in disease and their potential diagnostic and therapeutic utility is extremely reliant on in-depth quantification, measurement and identification of EV sub-populations. Quantification of EVs has presented several challenges, predominantly due to the small size of vesicles such as exosomes and the availability of various technologies to measure nanosized particles, each technology having its own limitations. Materials and Methods: A standardized methodology to measure the concentration of extracellular vesicles (EVs has been developed and tested. The method is based on measuring the EV concentration as a function of a defined size range. Blood plasma EVs are isolated and purified using size exclusion columns (qEV and consecutively measured with tunable resistive pulse sensing (TRPS. Six independent research groups measured liposome and EV samples with the aim to evaluate the developed methodology. Each group measured identical samples using up to 5 nanopores with 3 repeat measurements per pore. Descriptive statistics and unsupervised multivariate data analysis with principal component analysis (PCA were used to evaluate reproducibility across the groups and to explore and visualise possible patterns and outliers in EV and liposome data sets. Results: PCA revealed good reproducibility within and between laboratories, with few minor outlying samples. Measured mean liposome (not filtered with qEV and EV (filtered with qEV concentrations had coefficients of variance of 23.9% and 52.5%, respectively. The increased variance of the EV concentration measurements could be attributed to the use of qEVs and the polydisperse nature of EVs. Conclusion: The results of this study demonstrate the feasibility of this standardized methodology to facilitate comparable and reproducible EV concentration measurements.

  3. Polarographic study of Cd(2), Pb(2), Hg(1) in anhydrous acetic acid; Etude polarographique de Cd(2), Pb(2), Hg(1) dans l'acide acetique anhydre

    Energy Technology Data Exchange (ETDEWEB)

    Conesa-Botta, M C [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1966-07-01

    Anhydrous acetic acid is a solvent which can be compared to water as far as its behaviour towards acid-base reactions is concerned. It is in fact, like water both a proton acceptor (basic) - and as such it can provoke the dissociation of acids - and a proton donor (acid). This amphoteric behaviour is characterized by the equilibrium: 2 H O Ac {r_reversible} Ac OH{sub 2}{sup +} + Ac O{sup -} with K{sub i} = |Ac O H{sub 2}|{sup +} |Ac O{sup -}| = 10{sup -14.5} analogue to 2 H{sub 2}O {r_reversible} H{sub 3}O{sup +} + HO{sup -} with K{sub i} = |H{sub 3}O{sup +}| |HO{sup -}| = 10{sup -14} The acid-base reactions can in principle be characterized by a pH scale based on a definition similar to that for the pH scale in aqueous solutions. The essential difference however between aqueous and acetic acid solutions is due to the fact that acetic acid has a low dielectric constant. {epsilon} = 6.1 (at 25 deg. C) The ions therefore remain associated, almost completely, in the form of ion-pairs produced as a result of the strong electrostatic interactions. This phenomenon requires us to modify the reasoning usually applied to aqueous solutions. The new general methods of reasoning have been established and discussed by G. CHARLOT and B. TREMILLON. We will make use of them for the particular case under consideration. In the first part, we have employed the polarographic method for the study of the acetic complexes of two elements: cadmium(II) and lead (II). In the second part we have tried to show that mercurous halides are formed in acetic acid; we have attempted to determine their stability. (author) [French] L'acide acetique anhydre est un solvant qui peut etre rapproche de l'eau par son comportement envers les reactions acides-bases. Il est en effet, comme l'eau, a la fois accepteur de protons (basique) - et comme tel agit sur la dissociation des acides - et donneur de protons (acide). Ce pouvoir amphotere est caracterise par l'equilibre: 2 H O Ac {r_reversible} Ac OH{sub 2

  4. Differential pulse polarography of cadmium-and lead-urate and adsorptive stripping voltammetric determination of uric acid.

    Science.gov (United States)

    Gandour, M A; Ensaf-Aboul-Kasim; Amrallah, A H; Farghaly, O A

    1994-03-01

    The complex formation between uric acid and zinc, cadmium and lead ions has been investigated using differential pulse polarography in 0.01M NaNO(3). It is found that the complexes formed by Cd(II) and Pb(II) ions with uric acid have the stoichiometry of 1:2 and the logarithmic values of the apparent stability constant are 9.47 and 11.7, respectively. On the other hand, zinc(II) ions do not give any indication of complexation with uric acid. A sensitive voltammetric method is developed for the quantitative determination of uric acid. This method is based on controlled adsorptive preconcentration of uric acid on the hanging mercury drop electrode (HMDE), followed by tracing the voltammogram in the cathodic going potential scan. The modes used are direct current stripping voltammetry (DCSV) and differential pulse stripping voltammetry (DPSV). The detection limits found were 8 x 10(-9)M (quiescent period 15 sec) by DPSV and 1.6 x 10(-8)M by DCSV.

  5. Determination of the time dependent magnetic field distribution in pulsed-power systems

    Energy Technology Data Exchange (ETDEWEB)

    Maron, Y; Arad, R; Davara, G; Gregorian, L; Krasik, Ya; Kroupp, E; Safarty, M; Shpitalik, R; Weingarten, A [Weizmann Institute of Science, Rehovot (Israel). Faculty of Physics

    1997-12-31

    Time-dependent measurements of the magnetic field distributions in diode, plasma opening switch, and Z-pinch plasmas, based on the observation of the Zeeman effect or of the ion acceleration, are reviewed. Relatively high spatial resolution is obtained by locally doping the plasma with the desired species. Besides information on the device properties the measurements allowed for determining the plasma conductivity and for investigating the field penetration mechanism. Determination of the current density allowed the electron drift velocity to be known. (author). 4 figs., 16 refs.

  6. Application of pulsed field gel electrophoresis to determine γ-ray-induced double-strand breaks in yeast chromosomal molecules

    International Nuclear Information System (INIS)

    Friedl, A.A.; Hahn, K.; Eckardt-Schupp, F.; Kellerer, A.M.; Beisker, W.

    1993-01-01

    The frequency of DNA double-strand breaks (dsb) was determined in yeast cells exposed to γ-rays under anoxic conditions. Genomic DNA of treated cells was separated by pulsed field gel electrophoresis, and two different approaches for the evaluation of the gels were employed: (1) The DNA mass distribution profile obtained by electrophoresis was compared to computed profiles, and the number of DSB per unit length was then derived in terms of a fitting procedure; (2) hybridization of selected chromosomes was performed, and a comparison of the hybridization signals in treated and untreated samples was then used to derive the frequency of dsb. The two assays gave similar results for the frequency of dsb ((1.07 ± 0.06) x 10 -9 Gy -1 bp -1 and (0.93 ± 0.09) x 10 -9 Gy -1 bp -1 , respectively). The dsb frequency was found to be linearly dependent on dose. (author)

  7. Wet digestion and differential pulse stripping voltammetry determination of total chromium in the millet

    Directory of Open Access Journals (Sweden)

    Yaqin LIU

    2015-06-01

    Full Text Available The chromium content of millet is measured by HNO3-H2O2 digestion and electrochemical method. In the DTPA-HAc-NaAc system, the oxidation peak current of amalgam formed by hexavalent chrome ion is obtained in the plating mercury electrode, and the pre-treatment technology of wet digestion can meet the electrochemical determination. The optimized detection condition of electrochemical method for hexavalent chrome ion is 130 ℃ of digestion solution, 10 mL hydrogen peroxide, 38 mL nitric acid, and neutral of pH. The linear correlation coefficient of electrochemical method is 0.99, and the recovery of standard addition is 90%~110%. This method can be used to trace chromium (Ⅵ determination in millet.

  8. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Pryds, N. [Materials Research Department, Riso National Laboratory, DK-4000 Roskilde (Denmark)]. E-mail: nini.pryds@risoe.dk; Toftmann, B. [Department of Optics and Plasma Research, Riso National Laboratory, DK-4000 Roskilde (Denmark); Bilde-Sorensen, J.B. [Materials Research Department, Riso National Laboratory, DK-4000 Roskilde (Denmark); Schou, J. [Department of Optics and Plasma Research, Riso National Laboratory, DK-4000 Roskilde (Denmark); Linderoth, S. [Materials Research Department, Riso National Laboratory, DK-4000 Roskilde (Denmark)

    2006-04-30

    Films of yttria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive X-ray spectrometry in a scanning electron microscope (SEM) with use of a method similar to one described by Bishop and Poole. The attenuation of the electron-induced X-rays from the Si wafer by the film was monitored at a number of points along a diameter and the thickness was determined by Monte Carlo simulations of the attenuation for various values of film thickness with the program CASINO. These results have been compared with direct measurements in the SEM of the film thickness on a cross-section on one of the wafers. The results of these measurements demonstrate the ability of this technique to accurately determine the thickness of a large film, i.e. up to diameters of 125 mm, in a relatively short time, without destroying the substrate, without the need of a standard sample and without the need of a flat substrate. We have also demonstrated that by controlling the deposition parameters large-area YSZ films with uniform thickness can be produced.

  9. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    International Nuclear Information System (INIS)

    Pryds, N.; Toftmann, B.; Bilde-Sorensen, J.B.; Schou, J.; Linderoth, S.

    2006-01-01

    Films of yttria-stabilized zirconia (YSZ) on a polished silicon substrate of diameter up to 125 mm have been produced in a large-area pulsed laser deposition (PLD) setup under typical PLD conditions. The film thickness over the full film area has been determined by energy-dispersive X-ray spectrometry in a scanning electron microscope (SEM) with use of a method similar to one described by Bishop and Poole. The attenuation of the electron-induced X-rays from the Si wafer by the film was monitored at a number of points along a diameter and the thickness was determined by Monte Carlo simulations of the attenuation for various values of film thickness with the program CASINO. These results have been compared with direct measurements in the SEM of the film thickness on a cross-section on one of the wafers. The results of these measurements demonstrate the ability of this technique to accurately determine the thickness of a large film, i.e. up to diameters of 125 mm, in a relatively short time, without destroying the substrate, without the need of a standard sample and without the need of a flat substrate. We have also demonstrated that by controlling the deposition parameters large-area YSZ films with uniform thickness can be produced

  10. Adsorptive differential pulse voltammetry for determination of uranium in sea water

    International Nuclear Information System (INIS)

    Khandekar, R.N.; Raghunath, R.

    1990-01-01

    An adsorptive stripping voltammetric procedure for direct determination of trace quantities of uranium in sea water is described. Optimal conditions include pH 6.7, 2 x 10 -5 M 8-hydroxyquinoline (oxine) and collection potential of -0.4V (vs Ag/AgCl) at hanging mercury drop electrode. With controlled adsorptive accumulation for one min. a detection limit of 2.8 x 10 -10 M uranium is obtained. The response is linear upto 7 x 10 -8 M uranium and the relative standard deviation at 4 x 10 -9 M uranium is 11.5%. The effect of possible interference from other metals has been investigated. The accuracy of the method has been tested by comparison with the results obtained by fluorimetric method. (author). 2 figs., 1 tab., 20 refs

  11. Determination of uranium in sea water by adsorptive differential pulse voltametry

    International Nuclear Information System (INIS)

    Khandekar, R.N.; Raghunath, Radha

    1991-01-01

    An adsorptive stripping voltametric procedure for direct determination of trace quantities of uranium in sea water has been described. Optimal conditions include pH 6.7, 2 x 10 -5 M 8-hydroxy quinoline (oxine) and collection potential of -0.4V (Vs Ag/AgCl) at hanging mercury drop electrode. With controlled adsorptive accumulation for one minute a detection limit of 2.8 x 10 -10 M uranium is obtained. The response is linear upto 7 x 10 -8 M uranium and the relative standard deviation at 4 x 10 -9 M is 11.5%. The effect of possible interference from other metals has been investigated. (author). 14 refs., 1 tab

  12. Simultaneous determination of paracetamol and ibuprofen in pharmaceutical samples by differential pulse voltammetry using a boron-doped diamond electrode

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Amanda B.; Guimaraes, Carlos F.R.C.; Verly, Rodrigo M.; Silva, Leonardo M. da [Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG (Brazil). Departamento de Quimica; Torres, Livia M.F.C.; Carvalho, Junior, Alvaro D.; Santos, Wallans T. P. dos, E-mail: wallanst@ufvjm.edu.br [Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Diamantina, MG (Brazil). Departamento de Farmacia

    2014-03-15

    This work presents a simple, fast and low-cost methodology for the simultaneous determination of paracetamol (PC) and ibuprofen (IB) in pharmaceutical formulations by differential pulse voltammetry using a boron-doped diamond (BDD) electrode. A well-defined oxidation peak was observed using the BDD electrode for each analyte (0.85 V for PC and 1.72 V for IB (vs. Ag/AgCl)) in 0.1 mol L{sup -1} H{sub 2}SO{sub 4} solution containing 10% (v/v) of ethanol. Calibration curves for the simultaneous determination of PC and IB showed a linear response for both drugs in a concentration range of 20 to 400 μmol L{sup -1} (r{sup 2} = 0.999), with a detection limit of 7.1 μmol L{sup -1} for PC and 3.8 μmol L{sup -1} for IB. The addition-recovery studies in samples were about 100% and the results were validated by chromatographic methods. (author)

  13. Differential pulse voltammetric determination of nanomolar concentrations of antiviral drug acyclovir at polymer film modified glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Dorraji, Parisa S.; Jalali, Fahimeh, E-mail: fjalali@razi.ac.ir

    2016-04-01

    An electrochemical sensor for the sensitive detection of acyclovir was developed by the electropolymerization of Eriochrome black T at a pretreated glassy carbon electrode. The surface morphology of the modified electrode was characterized by field emission scanning electron microscopy. Under the optimized conditions, a significant electrochemical improvement was observed toward the electrooxidation of acyclovir on the modified electrode surface relative to the unmodified electrode. The detection limit of 12 nM and two linear calibration ranges of 0.03–0.3 μM and 0.3–1.5 μM were obtained for acyclovir determination using a differential pulse voltammetric method in acetate buffer (0.1 M, pH 4.0). Real sample studies were carried out in human blood serum and pharmaceutical formulations, which offered good recovery (98–102%). The electrode showed excellent reproducibility, selectivity and antifouling effects. - Graphical abstract: Eriochrome black T (EBT) was electropolymerized at the surface of a pretreated glassy carbon electrode. The modified electrode enhanced the oxidation current of acyclovir, significantly. The sensor was used in the determination of acyclovir in human blood serum samples and pharmaceutical dosages. - Highlights: • Construction of a voltammetric sensor for acyclovir is described. • Eriochrome black T was electropolymerized at the electrode surface. • The sensor improved the sensitivity of the electrode for monitoring acyclovir. • The recoveries and standard deviations were acceptable in spiked human blood serum. • The proposed sensor had good lifetime to be used in biological matrices.

  14. [Determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection].

    Science.gov (United States)

    Luo, Xiao-Fei; Yang, Yuan; Sun, Cheng-Jun

    2012-01-01

    To develop a method for the simultaneous determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection. Organophosphorus pesticides in food were extracted ultrasonically with water. Then the extract was cleaned-up with SPE disk and eluted with ethyl acetate. Finally the eluent was condensed to 1mL under N2 at 55 degrees C. Gas chromatography was applied for quantitative detection of the organophosphorus pesticides in the sample. The linear range of the method for all the pesticides were in the range of 0.01-0.5 mg/kg with correlation coefficients of 0.992-1.000. The detection limits of the method were in the range of 0.0005-0.01 mg/kg. The recoveries for most pesticides were 60%-120% with relative standard deviations of less than 15%. The method is simple, sensitive, environmentally friendly and suitable for the determination of organophosphorous pesticides in food.

  15. Simultaneous determination of paracetamol and ibuprofen in pharmaceutical samples by differential pulse voltammetry using a boron-doped diamond electrode

    International Nuclear Information System (INIS)

    Lima, Amanda B.; Guimaraes, Carlos F.R.C.; Verly, Rodrigo M.; Silva, Leonardo M. da; Torres, Livia M.F.C.; Carvalho Junior, Alvaro D.; Santos, Wallans T. P. dos

    2014-01-01

    This work presents a simple, fast and low-cost methodology for the simultaneous determination of paracetamol (PC) and ibuprofen (IB) in pharmaceutical formulations by differential pulse voltammetry using a boron-doped diamond (BDD) electrode. A well-defined oxidation peak was observed using the BDD electrode for each analyte (0.85 V for PC and 1.72 V for IB (vs. Ag/AgCl)) in 0.1 mol L -1 H 2 SO 4 solution containing 10% (v/v) of ethanol. Calibration curves for the simultaneous determination of PC and IB showed a linear response for both drugs in a concentration range of 20 to 400 μmol L -1 (r 2 = 0.999), with a detection limit of 7.1 μmol L -1 for PC and 3.8 μmol L -1 for IB. The addition-recovery studies in samples were about 100% and the results were validated by chromatographic methods. (author)

  16. Differential pulse voltammetric determination of nanomolar concentrations of antiviral drug acyclovir at polymer film modified glassy carbon electrode

    International Nuclear Information System (INIS)

    Dorraji, Parisa S.; Jalali, Fahimeh

    2016-01-01

    An electrochemical sensor for the sensitive detection of acyclovir was developed by the electropolymerization of Eriochrome black T at a pretreated glassy carbon electrode. The surface morphology of the modified electrode was characterized by field emission scanning electron microscopy. Under the optimized conditions, a significant electrochemical improvement was observed toward the electrooxidation of acyclovir on the modified electrode surface relative to the unmodified electrode. The detection limit of 12 nM and two linear calibration ranges of 0.03–0.3 μM and 0.3–1.5 μM were obtained for acyclovir determination using a differential pulse voltammetric method in acetate buffer (0.1 M, pH 4.0). Real sample studies were carried out in human blood serum and pharmaceutical formulations, which offered good recovery (98–102%). The electrode showed excellent reproducibility, selectivity and antifouling effects. - Graphical abstract: Eriochrome black T (EBT) was electropolymerized at the surface of a pretreated glassy carbon electrode. The modified electrode enhanced the oxidation current of acyclovir, significantly. The sensor was used in the determination of acyclovir in human blood serum samples and pharmaceutical dosages. - Highlights: • Construction of a voltammetric sensor for acyclovir is described. • Eriochrome black T was electropolymerized at the electrode surface. • The sensor improved the sensitivity of the electrode for monitoring acyclovir. • The recoveries and standard deviations were acceptable in spiked human blood serum. • The proposed sensor had good lifetime to be used in biological matrices.

  17. Determination of propylthiouracil in pharmaceuticals by differential pulse voltammetry using a cathodically pretreated boron-doped diamond electrode

    Energy Technology Data Exchange (ETDEWEB)

    Sartori, Elen Romao [Universidade Estadual de Londrina, PR (Brazil). Dept. de Quimica; Trench, Aline Barrios; Rocha-Filho, Romeu C.; Fatibello-Filho, Orlando, E-mail: bello@ufscar.br [Universidade Federal de Sao Carlos (UFSCAR), SP (Brazil). Dept. de Quimica

    2013-09-15

    A simple procedure is described for the determination of propylthiouracil (PTU) by differential pulse voltammetry (DPV) using a cathodically pretreated boron-doped diamond (BDD) electrode. Cyclic voltammetry studies indicate that the oxidation of PTU is irreversible at a peak potential of 1.42 V (vs. Ag/AgCl (3.0 mol L{sup -1} KCl)) in a Britton-Robinson (BR) buffer solution (pH 2.0). Under optimized conditions, the obtained analytical curve was linear (r = 0.9985) for the PTU concentration range of 1.0 to 29.1 {mu}mol L{sup -1} in a BR buffer solution (pH 2.0), with a detection limit of 0.90 {mu}mol L{sup -1}. The proposed method was successfully applied in the determination of PTU in pharmaceutical samples, with results in agreement at a 95% confidence level with those obtained using an official titration method. (author)

  18. Determination of the liquidus temperature of tin using the heat pulse-based melting and comparison with traditional methods

    Science.gov (United States)

    Joung, Wukchul; Park, Jihye; Pearce, Jonathan V.

    2018-06-01

    In this work, the liquidus temperature of tin was determined by melting the sample using the pressure-controlled loop heat pipe. Square wave-type pressure steps generated periodic 0.7 °C temperature steps in the isothermal region in the vicinity of the tin sample, and the tin was melted with controllable heat pulses from the generated temperature changes. The melting temperatures at specific melted fractions were measured, and they were extrapolated to the melted fraction of unity to determine the liquidus temperature of tin. To investigate the influence of the impurity distribution on the melting behavior, a molten tin sample was solidified by an outward slow freezing or by quenching to segregate the impurities inside the sample with concentrations increasing outwards or to spread the impurities uniformly, respectively. The measured melting temperatures followed the local solidus temperature variations well in the case of the segregated sample and stayed near the solidus temperature in the quenched sample due to the microscopic melting behavior. The extrapolated melting temperatures of the segregated and quenched samples were 0.95 mK and 0.49 mK higher than the outside-nucleated freezing temperature of tin (with uncertainties of 0.15 mK and 0.16 mK, at approximately 95% level of confidence), respectively. The extrapolated melting temperature of the segregated sample was supposed to be a closer approximation to the liquidus temperature of tin, whereas the quenched sample yielded the possibility of a misleading extrapolation to the solidus temperature. Therefore, the determination of the liquidus temperature could result in different extrapolated melting temperatures depending on the way the impurities were distributed within the sample, which has implications for the contemporary methodology for realizing temperature fixed points of the International Temperature Scale of 1990 (ITS-90).

  19. LOW COST ANALYZER FOR THE DETERMINATION OF PHOSPHORUS BASED ON OPEN-SOURCE HARDWARE AND PULSED FLOWS

    Directory of Open Access Journals (Sweden)

    Pablo González

    2016-04-01

    Full Text Available The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.

  20. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  1. Preparation and electrochemical application of rutin biosensor for differential pulse voltammetric determination of NADH in the presence of acetaminophen

    Directory of Open Access Journals (Sweden)

    HAMID R. ZARE

    2010-10-01

    Full Text Available The electrocatalytic behavior of reduced nicotinamide adenine di-nucleotide (NADH was studied at the surface of a rutin biosensor, using various electrochemical methods. According to the results, the rutin biosensor had a strongly electrocatalytic effect on the oxidation of NADH with the overpotential being decreased by about 450 mV as compared to the process at a bare glassy carbon electrode, GCE. This value is significantly greater than the value of 220 mV that was reported for rutin embedded in a lipid-cast film. The kinetic parameters of the electron transfer coefficient, a, and the heterogeneous charge transfer rate constant, kh, for the electrocatalytic oxidation of NADH at the rutin biosensor were estimated. Furthermore, the linear dynamic range; sensitivity and limit of detection for NADH were evaluated using the differential pulse voltammetry method. The advantages of this biosensor for the determination of NADH are excellent catalytic activity and reproducibility, good detection limit and high exchange current density. The rutin biosensor could separate the oxidation peak potentials of NADH and acetaminophen present in the same solution while at a bare GCE, the peak potentials were indistinguishable.

  2. Experimental subcritical reactivity determinations employing APSD measurements with pulse mode detectors in the IPEN/MB-01 reactor

    International Nuclear Information System (INIS)

    Santos, Adimir dos; Lee, Seung Min; Diniz, Ricardo; Jerez, Rogerio

    2011-01-01

    This work aims to determine experimentally the subcritical reactivity levels of several configurations of the IPEN/MB-01 reactor in an approach based on the subcritical kinetic model developed by Gandini and Salvatores. The procedure employs the measurements of the APSD (Auto Power Spectral Density) using pulse mode detectors. The proposed approach is based only on measured quantities such as counting rates and the parameters arising from the least square approach of the APSD. Other difficult quantity such as detector efficiencies is not needed in the method. Several measurements of APSD were performed in varying degrees of sub-criticality (up to around -7000 pcm). The APSD data were least-square fitted to get the prompt decay mode (α). Beside the startup source, an external neutron sources of Am-Be was installed near the core in order to improve neutron count statistics. The final experimental results are of very good quality. The experiment shows clearly that the classical one point kinetic theory cannot describe the measured reactivity. MCNP K eff results were compared to the corresponding experimental results. The agreement was fairly good. (author)

  3. Determination of sugar compounds in olive plant extracts by anion-exchange chromatography with pulsed amperometric detection.

    Science.gov (United States)

    Cataldi, T R; Margiotta, G; Iasi, L; Di Chio, B; Xiloyannis, C; Bufo, S A

    2000-08-15

    We describe a chromatographic method that uses isocratic elution and pulsed amperometric detection to determine soluble carbohydrates in plant tissues. Such a method provides a rapid and convenient means to obtain a complete profile of the sugar components of leaves and roots from olive (Olea europaea L. cv. Coratina) plants. A simple purification of plant extracts using pure water was developed, which is far less time-consuming and retains a high level of accuracy. Excellent separation of myo-inositol, galactinol, mannitol, galactose, glucose, fructose, sucrose, raffinose, and stachyose was achieved with an anion-exchange column and 12 mM NaOH spiked with 1 mM barium acetate as an eluent. At a flow rate of 1.0 mL/min, the time of analysis was less than 25 min, and repeatability of the method on the order of 2.2% as RSD or better for retention times and lower than 5.2% for peak areas. Recoveries approximated 100% (range 97.2-104.5%), and the method provided good precision with a coefficient of variation which ranged between 0.9 and 3.3%. Among identified carbohydrates extracted from leaves and roots of olive plants, glucose and mannitol were major compounds. Their molar ratio was estimated to be 1.2+/-0.1 and 2.2+/-0.3 for olive leaves and roots, respectively. The occurrence of soluble galactinol in plant tissues was also validated.

  4. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  5. Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Sanghavi, Bankim J. [Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai 400 098, Maharashtra (India); Srivastava, Ashwini K., E-mail: aksrivastava@chem.mu.ac.i [Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai 400 098, Maharashtra (India)

    2011-04-15

    A Nafion-carbon nanotube-modified glassy carbon electrode (NAF-CNT-GCE) was developed for the determination of venlafaxine (VF) and desvenlafaxine (DVF). The electrochemical behavior of both these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and adsorptive stripping differential pulse voltammetry (AdSDPV). The surface morphology of the electrodes has been studied by means of scanning electron microscopy (SEM). These studies revealed that the oxidation of VF and DVF is facilitated at NAF-CNT-GCE. After optimization of analytical conditions employing this electrode at pH 7.0 in Britton-Robinson buffer (0.05 M) for VF and pH 5.0 in acetate buffer (0.1 M) for DVF, the peak currents for both the molecules were found to vary linearly with their concentrations in the range of 3.81 x 10{sup -8}-6.22 x 10{sup -5} M for VF and 5.33 x 10{sup -8}-3.58 x 10{sup -5} M for DVF. The detection limits (S/N = 3) of 1.24 x 10{sup -8} and 2.11 x 10{sup -8} M were obtained for VF and DVF, respectively, using AdSDPV. The prepared modified electrode showed several advantages, such as simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of VF and DVF in pharmaceutical formulations, urine and blood serum samples.

  6. Pulsed amperometric detection at glassy carbon electrodes: A new waveform for sensitive and reproducible determination of electroactive compounds.

    Science.gov (United States)

    Nardiello, Donatella; Palermo, Carmen; Natale, Anna; Quinto, Maurizio; Centonze, Diego

    2015-09-24

    In this work, the application of a new pulsed amperometric detection (PAD) waveform at a glassy carbon electrode, operating in typical chromatographic mobile phases, is proposed for the sensitive and reproducible determination of arylethanolaminic and phenolic moiety based compounds (e.g. beta-agonists and polyphenols). Preliminary experiments by cyclic voltammetry were carried out to investigate the electrochemical behaviour and to select the detection and cleaning electrode potentials. The proposed potential-time profile was designed to prevent the carbon electrode fouling under repeated analyses, thus ensuring a reproducible and sensitive quantitative determination, without the need of any mechanical or chemical electrode cleaning procedure. The waveform electrochemical parameters, including detection and delay times, were optimized in terms of sensitivity, limit of detection and response stability. The optimized waveform allowed the sensitive and stable detection of model compounds, such as clenbuterol and caffeic acid, that showed detection limits of 0.1 μg L(-1) and 14 μg L(-1), quantification limits of 0.4 μg L(-1) and 46 μg L(-1), and linearity up to 100 μg L(-1) (r = 0.9993) and 10 mg L(-1) (r = 0.9998), respectively. Similar results were obtained for other compounds of the same classes, with precision values under repeatability conditions ranging from 3.0 to 5.9%. The proposed method can be then considered as an excellent alternative to the post-column detection of beta-agonists, phenols and polyphenols. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Differential pulse cathodic stripping voltammetric determination of uranium with arsenazo-III at the hanging mercury dropping electrode

    Energy Technology Data Exchange (ETDEWEB)

    Kadi, M.W.; El-Shahawi, M.S. [Chemistry Dept., King Abdulaziz Univ., Jeddah (Saudi Arabia)

    2009-07-01

    An accurate, inexpensive and less laborious controlled adsorptive accumulation of uranium(VI)-arsenazo-III on a hanging mercury drop electrode (HMDE) has been developed for uranium(VI) determination. The method is based upon the collection of uranium(VI)-arsenazo-III complex at pH 5-6 at the HMDE and subsequent direct stripping measurement of the element in the nanomolar concentration level. The cathodic peak current (i{sub p,c}) of the adsorbed complex ions of uranium(VI) was measured at -0.35 V vs. Ag/AgCl reference electrode by differential pulse cathodic stripping voltammetry (DP-CSV), proceeded by an accumulation period of 150s2.5 in Britton-Robinson buffer of pH 5. The plot of the resulting i{sub p,c} vs. uranium(VI) concentration was linear in the range 2.1 x 10{sup -9} to 9.60 x 10{sup -7} mol L{sup -1} uranium(VI) and tended to level off at above 9.6 x 10{sup -7} mol L{sup -1}. The limits of detection and quantification of uranium(VI) were found to be 4.7 x 10{sup -10} and 1.5 x 10{sup -9} mol L{sup -1}, respectively. A relative standard deviation of {+-}2.39% (n = 5) at 8.5 x 10{sup -7} mol L{sup -1} uranium(VI) was obtained. The method was validated by comparing the results with that obtained by ICP-MS method with RSD less than {+-}3.3%. The method was applied successfully for the analysis of uranium in certified reference material (IAEA soil-7), and in phosphate fertilizers. (orig.)

  8. Differential pulse voltammetric determination of methyl parathion based on multiwalled carbon nanotubes-poly(acrylamide) nanocomposite film modified electrode

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Yanbo [Department of Chemistry and Shanghai Key Laboratory of Green Chemistry and Chemical Process, East China Normal University, 3663 Zhongshan Road(N), Shanghai, 200062 (China); College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001 (China); Yu, Dajun; Yu, Yanyan [Department of Chemistry and Shanghai Key Laboratory of Green Chemistry and Chemical Process, East China Normal University, 3663 Zhongshan Road(N), Shanghai, 200062 (China); Zhou, Tianshu [Department of Environmental Science, East China Normal University, 3663 Zhongshan Road(N), Shanghai, 200062 (China); Shi, Guoyue, E-mail: gyshi@chem.ecnu.edu.cn [Department of Chemistry and Shanghai Key Laboratory of Green Chemistry and Chemical Process, East China Normal University, 3663 Zhongshan Road(N), Shanghai, 200062 (China)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer A sensitive electrochemical sensor for detecting methyl parathion in environmental samples. Black-Right-Pointing-Pointer The preparation, characterization and application of this novel MWCNTs-PAAM nanocomposite. Black-Right-Pointing-Pointer The MWCNTs-PAAM/GCE exhibited a high adsorption and strong affinity toward methyl parathion. Black-Right-Pointing-Pointer Wide linear range and low detection limit of the proposed method for detecting methyl parathion. - Abstract: A sensitive electrochemical differential pulse voltammetry method was developed for detecting methyl parathion based on multiwalled carbon nanotubes-poly(acrylamide) (MWCNTs-PAAM) nanocomposite film modified glassy carbon electrode. The novel MWCNTs-PAAM nanocomposite, containing high content of amide groups, was synthesized by PAAM polymerizing at the vinyl group functionalized MWCNTs surface using free radical polymerization. The MWCNTs-PAAM nanocomposite was characterized by Fourier transform infrared spectroscopy, thermal gravimetric analysis and scanning electron microscopy. Electrochemical behavior and interference studies of MWCNTs-PAAM/GCE for methyl parathion were investigated. The experimental results demonstrated that the MWCNTs-PAAM/GCE exhibited a high adsorption and strong affinity toward methyl parathion compared with some metal ions and nitroaromatic compounds, which exist in environmental samples. The adsorbed amount of methyl parathion on the MWCNTs-PAAM/GCE approached the equilibrium value upon 5 min adsorption time. A linear calibration curve for methyl parathion was obtained in the concentration range from 5.0 Multiplication-Sign 10{sup -9} to 1.0 Multiplication-Sign 10{sup -5} mol L{sup -1}, with a detection limit of 2.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. The MWCNTs-PAAM/GCE was proved to be a suitable sensing tool for the fast, sensitive and selective determination of methyl parathion in environmental water samples.

  9. Differential pulse voltammetric determination of methyl parathion based on multiwalled carbon nanotubes–poly(acrylamide) nanocomposite film modified electrode

    International Nuclear Information System (INIS)

    Zeng, Yanbo; Yu, Dajun; Yu, Yanyan; Zhou, Tianshu; Shi, Guoyue

    2012-01-01

    Highlights: ► A sensitive electrochemical sensor for detecting methyl parathion in environmental samples. ► The preparation, characterization and application of this novel MWCNTs–PAAM nanocomposite. ► The MWCNTs–PAAM/GCE exhibited a high adsorption and strong affinity toward methyl parathion. ► Wide linear range and low detection limit of the proposed method for detecting methyl parathion. - Abstract: A sensitive electrochemical differential pulse voltammetry method was developed for detecting methyl parathion based on multiwalled carbon nanotubes–poly(acrylamide) (MWCNTs–PAAM) nanocomposite film modified glassy carbon electrode. The novel MWCNTs–PAAM nanocomposite, containing high content of amide groups, was synthesized by PAAM polymerizing at the vinyl group functionalized MWCNTs surface using free radical polymerization. The MWCNTs–PAAM nanocomposite was characterized by Fourier transform infrared spectroscopy, thermal gravimetric analysis and scanning electron microscopy. Electrochemical behavior and interference studies of MWCNTs–PAAM/GCE for methyl parathion were investigated. The experimental results demonstrated that the MWCNTs–PAAM/GCE exhibited a high adsorption and strong affinity toward methyl parathion compared with some metal ions and nitroaromatic compounds, which exist in environmental samples. The adsorbed amount of methyl parathion on the MWCNTs–PAAM/GCE approached the equilibrium value upon 5 min adsorption time. A linear calibration curve for methyl parathion was obtained in the concentration range from 5.0 × 10 −9 to 1.0 × 10 −5 mol L −1 , with a detection limit of 2.0 × 10 −9 mol L −1 . The MWCNTs–PAAM/GCE was proved to be a suitable sensing tool for the fast, sensitive and selective determination of methyl parathion in environmental water samples.

  10. Age-Specific Determinants of Pulse Wave Velocity among Metabolic Syndrome Components, Inflammatory Markers, and Oxidative Stress.

    Science.gov (United States)

    Kim, Minkyung; Kim, Minjoo; Yoo, Hye Jin; Lee, Seung Yeon; Lee, Sang-Hyun; Lee, Jong Ho

    2018-02-01

    Pulse wave velocity (PWV) is thought to have different relationships with metabolic syndrome (MS) components, inflammatory markers, and oxidative stress, according to age. However, age-specific determinants of PWV have not yet been studied. We investigated age-dependent relationships among PWV and MS components, inflammatory markers, and oxidative stress. A total of 4,318 subjects were divided into 4 groups: 19-34 y (n=687), 35-44 y (n=1,413), 45-54 y (n=1,384), and 55-79 y (n=834). MS components, brachial-ankle PWV (baPWV), high-sensitivity C-reactive protein (hs-CRP), and oxidative stress markers were measured. There were age-related increases in MS, body mass index (BMI), waist circumference, systolic blood pressure (SBP), diastolic BP (DBP), triglycerides, glucose, hs-CRP, oxidized low-density lipoprotein (LDL), 8-epi-prostaglandin F 2α (8-epi-PGF 2α ), and baPWV. BaPWV was significantly associated with sex and elevated BP in the 19-34 y group; with age, sex, BMI, elevated BP and triglycerides in the 35-44 y group; with age, sex, elevated BP, fasting glucose, hs-CRP and oxidized LDL in the 45-54 y group; and with age, BMI, elevated BP, fasting glucose and oxidized LDL in the 55-79 y group. Our results show that age-related increases in baPWV are associated with age-related changes in MS components, inflammatory markers, and oxidative stress. However, each of these factors has an age-specific, different impact on arterial stiffness. In particular, oxidative stress may be independently associated with arterial stiffness in individuals older than 45 y.

  11. Determination of the stochastic layer properties induced by magnetic perturbations via heat pulse experiments at ASDEX upgrade

    Directory of Open Access Journals (Sweden)

    D. Brida

    2017-08-01

    Full Text Available A heat pulse experiment was carried out in the tokamak ASDEX Upgrade to estimate the stochastic layer width of a deuterium L-mode discharge with externally applied Magnetic Perturbations. The method relies on the deposition of ECRH pulses in the plasma edge while measuring the divertor target heat flux with high temporal resolution IR thermography and Langmuir probes. The experimental results were compared to simulations of the time dependent heat pulse propagation on a constant plasma background with the EMC3-EIRENE code package, using an ad-hoc screening model. If no screening was taken into account in the simulations a decrease in the characteristic heat pulse propagation time was observed, which shows that the heat transport is enhanced compared to the screened cases. No such enhancement was found in the experiment, indicating strong screening. In further simulations the effect of screening on the target fluxes was investigated for varying densities. For low densities it was found that screening reduces the strike line splitting strongly, while for higher densities no strong strike line splitting was found, independent of the screening degree. For strongly detached L-mode conditions with MPs experiments at AUG indicate that the lobe structures vanish completely.

  12. Influence of silicon orientation and cantilever undercut on the determination of Young's modulus of pulsed laser deposited PZT

    NARCIS (Netherlands)

    Nazeer, H.; Woldering, L.A.; Abelmann, Leon; Nguyen, Duc Minh; Rijnders, Augustinus J.H.M.; Elwenspoek, Michael Curt

    In this work we show for the first time that the effective in-plane Young’s modulus of PbZr0.52Ti0.48O3 (PZT) thin films, deposited by pulsed laser deposition (PLD) on dedicated single crystal silicon cantilevers, is independent of the in-plane orientation of cantilevers.

  13. Comparison of different pulse sequences for in vivo determination of T1 relaxation times in the human brain

    DEFF Research Database (Denmark)

    Kjaer, L; Henriksen, O

    1988-01-01

    ). T1 measurements were performed on the human brain using a whole body MR scanner operating at 1.5 tesla. Three different pulse sequences were compared including two 6-points inversion recovery (IR) sequences with TR = 2.0 s and 4.0, respectively, and a 12-points partial saturation inversion recovery...

  14. Simultaneous determination of 13 carbohydrates using high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry.

    Science.gov (United States)

    Zhao, Dan; Feng, Feng; Yuan, Fei; Su, Jin; Cheng, Yan; Wu, Hanqiu; Song, Kun; Nie, Bo; Yu, Lian; Zhang, Feng

    2017-04-01

    A simple, accurate, and highly sensitive method was developed for the determination of 13 carbohydrates in polysaccharide of Spirulina platensis based on high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry. Samples were extracted with deionized water using ultrasonic-assisted extraction, and the ultrasound-assisted extraction conditions were optimized by Box-Behnken design. Then the extracted polysaccharide was hydrolyzed by adding 1 mol/L trifluoroacetic acid before determination by high-performance anion-exchange chromatography coupled with pulsed amperometric detection and confirmed by high-performance anion-exchange chromatography coupled with mass spectrometry. The high-performance anion-exchange chromatography coupled with pulsed amperometric detection method was performed on a CarboPac PA20 column by gradient elution using deionized water, 0.1 mol/L sodium hydroxide solution, and 0.4 mol/L sodium acetate solution. Excellent linearity was observed in the range of 0.05-10 mg/L. The average recoveries ranged from 80.7 to 121.7%. The limits of detection and limits of quantification for 13 carbohydrates were 0.02-0.10 and 0.2-1.2  μg/kg, respectively. The developed method has been successfully applied to ambient samples, and the results indicated that high-performance anion-exchange chromatography coupled with pulsed amperometric detection and mass spectrometry could provide a rapid and accurate method for the simultaneous determination of carbohydrates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  16. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    OpenAIRE

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detec...

  17. [Determination of calcium, magnesium and potassium in nurtured cell by AAS with quick-pulsed nebulization technique and NaOH base digestion].

    Science.gov (United States)

    Shi, C; Gao, S; Gun, S

    1997-06-01

    The sample is digested with 6% NaOH solution and an amount of 50 microl is used for protein content analysis by the method of Comassie Brilliant Blue G250, the residual is diluted with equal 0.4% Lathanurm-EDTA solution. Its Calcium magensium and potassium content are determined by AAS. With quick-pulsed nebulization technique. When a self-made micro-sampling device is used, 20microl of sample volume is needed and it is only the 1/10 approximately 1/20 of the sample volume required for conventional determination. Sensitivity, precision and rate of recovery agree well with those using regular wet ashing method.

  18. System Performance Testing of the Pulse-Echo Ultrasonic Instrument for Critical Velocity Determination during Hanford Tank Waste Transfer Operations - 13584

    Energy Technology Data Exchange (ETDEWEB)

    Denslow, Kayte M.; Bontha, Jagannadha R.; Adkins, Harold E.; Jenks, Jeromy W.J.; Hopkins, Derek F. [Pacific Northwest National Laboratory, Richland, Washington 99354 (United States); Thien, Michael G.; Kelly, Steven E.; Wooley, Theodore A. [Washington River Protection Solutions, Richland, Washington 99354 (United States)

    2013-07-01

    The delivery of Hanford double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) is governed by specific Waste Acceptance Criteria that are identified in ICD 19 - Interface Control Document for Waste Feed. Waste must be certified as acceptable before it can be delivered to the WTP. The fluid transfer velocity at which solid particulate deposition occurs in waste slurry transport piping (critical velocity) is a key waste acceptance parameter that must be accurately characterized to determine if the waste is acceptable for transfer to the WTP. Washington River Protection Solutions and the Pacific Northwest National Laboratory have been evaluating the ultrasonic PulseEcho instrument since 2010 for its ability to detect particle settling and determine critical velocity in a horizontal slurry transport pipeline for slurries containing particles with a mean particle diameter of =14 micrometers (μm). In 2012 the PulseEcho instrument was further evaluated under WRPS' System Performance test campaign to identify critical velocities for slurries that are expected to be encountered during Hanford tank waste retrieval operations or bounding for tank waste feed. This three-year evaluation has demonstrated the ability of the ultrasonic PulseEcho instrument to detect the onset of critical velocity for a broad range of physical and rheological slurry properties that are likely encountered during the waste feed transfer operations between the Hanford tank farms and the WTP. (authors)

  19. Determination of the apparent porosity level of refractory concrete during a sintering process using an ultrasonic pulse velocity technique and image analysis

    Directory of Open Access Journals (Sweden)

    LJUBICA M. PAVLOVIĆ

    2010-03-01

    Full Text Available Concrete which undergoes a thermal treatment before (pre-casted concrete blocks and during (concrete embedded in-situ its life-service can be applied in plants operating at high temperature and as thermal insulation. Sintering is a process which occurs within a concrete structure in such conditions. Progression of sintering process can be monitored by the change of the porosity parameters determined with a nondestructive test method - ultrasonic pulse velocity and computer program for image analysis. The experiment has been performed on the samples of corundum and bauxite concrete composites. The apparent porosity of the samples thermally treated at 110, 800, 1000, 1300 and 1500 C was primary investigated with a standard laboratory procedure. Sintering parameters were calculated from the creep testing. The loss of strength and material degradation occurred in concrete when it was subjected to the increased temperature and a compressive load. Mechanical properties indicate and monitor changes within microstructure. The level of surface deterioration after the thermal treatment was determined using Image Pro Plus program. Mechanical strength was estimated using ultrasonic pulse velocity testing. Nondestructive ultrasonic mea¬surement was used as a qualitative description of the porosity change in specimens which is the result of the sintering process. The ultrasonic pulse velocity technique and image analysis proved to be reliable methods for monitoring of micro-structural change during the thermal treatment and service life of refractory concrete.

  20. Determination of reactivity of multiplying systems filled with spherical HTGR-fuel elements using kinetic methods with regard to the pulsed-neutron method

    International Nuclear Information System (INIS)

    Drueke, V.

    1978-06-01

    At three critical or subcritical facilities - two of them filled with spherical HTGR-fuel elements - the reactivity is determined using kinetic methods. Besides the inverskinetic method the applicability of the pulsed-neutron method is investigated. The experimental results using the pulsed-neutron method are compared partly with the inverskinetic method and partly with diffusion-calculations. It is shown, that in the HTGR the space dependence of the reactivity in radial direction is not remarkable in spite of the 'kinetic distortion'; on the contrary in axial direction - the direction of the external neutron source - space dependent reactivity worths are measured. The results of the pulsed-neutron methods of Sjoestrand and Simmons-King are rather good applicable in all configurations. For the method of Sjoestrand it is necessary to select the detector positions, whereas for Simmons-King the calculated life-time determines the results. Therefore it is proposed to compare calculated and measured decay constants of the prompt neutron field in future. (orig.) [de

  1. Direct spectral analysis and determination of high content of carcinogenic bromine in bread using UV pulsed laser induced breakdown spectroscopy.

    Science.gov (United States)

    Mehder, A O; Gondal, Mohammed A; Dastageer, Mohamed A; Habibullah, Yusuf B; Iqbal, Mohammed A; Oloore, Luqman E; Gondal, Bilal

    2016-01-01

    Laser induced breakdown spectroscopy (LIBS) was applied for the detection of carcinogenic elements like bromine in four representative brands of loaf bread samples and the measured bromine concentrations were 352, 157, 451, and 311 ppm, using Br I (827.2 nm) atomic transition line as the finger print atomic transition. Our LIBS system is equipped with a pulsed laser of wavelength 266 nm with energy 25 mJ pulse(-1), 8 ns pulse duration, 20 Hz repetition rate, and a gated ICCD camera. The LIBS system was calibrated with the standards of known concentrations in the sample (bread) matrix and such plot is linear in 20-500 ppm range. The capability of our system in terms of limit of detection and relative accuracy with respect to the standard inductively coupled plasma mass spectrometry (ICPMS) technique was evaluated and these values were 5.09 ppm and 0.01-0.05, respectively, which ensures the applicability of our system for Br trace level detection, and LIBS results are in excellent agreement with that of ICPMS results.

  2. Determination of the form of very short luminous pulses. Application to scintillation phenomena (1962); Determination de la forme des impulsions lumineuses tres breves. Application aux phenomenes de scintillation (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Koechlin, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-12-15

    During studies on photomultipliers and scintillators we have developed a new method of measurement making it possible to determine with precision the form of luminous pulses whose duration may be less that of an anodic photomultiplier pulse. This method, which can be applied to non-recurrent pulses, makes possible the study of scintillations caused by particles of photons in the case where it is possible to operate on a large number of pulses having the same form. We have thus determined the form of the scintillations of various fluorescent liquids excited by {alpha} particles and {gamma} photons. The results obtained are in agreement with the energy transfer theory for organic liquids elaborated by H. Kallmann and M. FURST. The results are used to determine exactly the parameters occurring in the theory. (author) [French] A l'occasion d'etudes sur les photomultiplicateurs et les scintillateurs nous avons mis au point une nouvelle methode de mesure permettant de determiner avec precision la forme des impulsions lumineuses dont la duree peut etre inferieure a celle d'une impulsion anodique de photomultiplicateur. Cette methode, qui peut s'appliquer a des impulsions non recurrentes, permet d'etudier les scintillations provoquees par des particules ou des photons, a la seule condition que l'on puisse operer sur un grand nombre d'impulsions ayant la meme forme. Nous avons determine ainsi la forme des scintillations des divers liquides fluorescents excites par des particules {alpha} et des photons {gamma} Les resultats obtenus sont en accord avec la theorie des transferts d'energie dans les scintillateurs organiques, elaboree par H. KALLMANN et M. FURST. Ils conduisent a une determination precise des parameters intervenant dans cette theorie. (auteur)

  3. Development of a computer program to determine the pulse-height distribution in a gamma-ray detector from an arbitrary geometry source -feasibility study

    International Nuclear Information System (INIS)

    Currie, G.D.; Marshall, M.

    1989-03-01

    The feasibility of developing a computer program suitable for evaluating the pulse-height spectrum in a gamma-ray detector from a complex geometry source has been examined. A selection of relevant programs, Monte Carlo radiation transport codes, have been identified and their applicability to this study discussed. It is proposed that the computation be performed in two parts: the evaluation of the photon fluence at the detector using a photon transport code, and calculation of the pulse-height distribution from this spectrum using response functions determined with an electron-photon transport code. The two transport codes selected to perform this procedure are MCNP (Monte Carlo Neutron Photon code), and EGS4 (Electron Gamma Shower code). (Author)

  4. Using a pulse oximeter to determine clinical depth of anesthesia-investigation of the utility of the perfusion index.

    Science.gov (United States)

    Krishnamohan, Anirudh; Siriwardana, Viraj; Skowno, Justin J

    2016-11-01

    Peripheral vasodilation is a well-recognized side effect of general anesthesia, and induces changes in the amplitude of the pulse plethysmograph (PPG) waveform. This can be continuously quantitaed using the Perfusion Index (PI), a ratio of the pulsatile to nonpulsatile signal amplitude in the PPG waveform. We hypothesized that the perfusion index would rise with the induction of anesthesia in children, and fall with emergence, and performed a prospective, observational study to test this. Our primary aim was to test whether the different clinical stages of anesthesia were associated with changes in the perfusion index, and the secondary aim was to test the correlation between the normalized perfusion index and the MAC value. Twenty-one patients between the ages of 1 and 18 undergoing minor procedures with no anticipated painful stimuli were recruited. Patients with significant illnesses were excluded. Data collection commenced with a preinduction baseline, and data were collected continuously, with event marking, until completion of the anesthesia and removal of the pulse oximeter. Data collected included perfusion index, heart rate, and anesthetic gas concentration values. A normalized perfusion index was calculated by subtracting the initial baseline perfusion index value from all perfusion index values, allowing changes, from a standardized initial baseline value of zero, to be analyzed. During induction, the mean normalized perfusion index rose from 0.0 to 4.2, and then declined to 0.470 when the patients returned to consciousness. P < 0.001 using repeated measures anova test. The normalized perfusion index was correlated with MAC values (r 2 = 0.33, 95% CI 0.18-0.47, P < 0.01). The perfusion index changed significantly during different stages of anesthesia. There is a significant correlation between the perfusion index, measured by pulse oximetry, and the MAC value, in pediatric patients undergoing minor procedures. © 2016 John Wiley & Sons Ltd.

  5. Ventricular repolarization time, location of pacing stimulus and current pulse amplitude conspire to determine arrhythmogenicity in mice

    DEFF Research Database (Denmark)

    Speerschneider, T; Grubb, Søren Jahn; Olesen, S P

    2017-01-01

    ) were measured in isolated hearts using floating microelectrodes. RESULTS: Proarrhythmia in WT and KChIP2(-/-) was not sensitive to changes in refractory periods. Action potentials were longer in KChIP2(-/-) hearts compared to WT hearts. Isolated WT hearts had large apico-basal dispersion...... of repolarization time, whereas hearts from KChIP2(-/-) mice had large left-to-right ventricular dispersion of repolarization time. Pacing from the right ventricle in KChIP2(-/-) mice in vivo revealed significant lower current pulse amplitudes needed to induce arrhythmias in these mice. CONCLUSION: Large...

  6. Real-time flow - determination of vena cava inferior on two different levels via 'RACE' pulse sequence in MR

    International Nuclear Information System (INIS)

    Helzel, M.V.; Mueller, E.

    1993-01-01

    A new and simple parameter for quantiative evaluation of liver perfusion is outlined: Post-sinusoidal quantitative measurement of the entire liver venous flow: This is a result of the differences in evaluated flow volumes at two different levels in the inferior V.cava. The first level is the height of diaphragm, and the second is situated just cranial of the renal vessels. Normal values obtained from a group of healthy volunteers are presented. A gradient-echo pulse sequence called RACE, enabling flow measurements in real-time, is outlined. (orig.) [de

  7. Determination of low α activity levels applying a pulse discrimination system to a conventional liquid scintillation unit

    International Nuclear Information System (INIS)

    Oliveira, A.A.; Bonino, A.D.

    1983-01-01

    The described system allows the measurement of α activity in the presence of β/γ activities in various types of samples. Pulse shape discrimination of the signal from a conventional liquid scintillation unit is used for assessing the α activity in samples obtained from several radiochemical processes as well as in samples from area and surface monitoring, without separating for the γ and β emitters present. Additionally, the considerable background reduction attained by this method makes possible the utilization of automatic liquid scintillation systems for measuring enviromental and occupational monitoring samples. (Author) [es

  8. Population Genetic Structure of Listeria monocytogenes Strains as Determined by Pulsed-Field Gel Electrophoresis and Multilocus Sequence Typing

    DEFF Research Database (Denmark)

    Henri, Clémentine; Félix, Benjamin; Guillier, Laurent

    2016-01-01

    on the basis of different pulsed-field gel electrophoresis (PFGE) clusters, serotypes, and strain origins and typed by multilocus sequence typing (MLST), and the MLST results were supplemented with MLST data available from Institut Pasteur, representing human and additional food strains from France....... The distribution of sequence types (STs) was compared between food and clinical strains on a panel of 675 strains. High congruence between PFGE and MLST was found. Out of 73 PFGE clusters, the two most prevalent corresponded to ST9 and ST121. Using original statistical analysis, we demonstrated that (i...

  9. Differential pulse voltammetric determination of salbutamol sulfate in syrup pharmaceutical formulation using poly(4-amino-3-hydroxynaphthalene sulfonic acid modified glassy carbon electrode

    Directory of Open Access Journals (Sweden)

    Meareg Amare

    2017-10-01

    Full Text Available A new method for determination of salbutamol sulfate has been developed using poly(4-amino-3-hydroxynaphthalene sulfonic acid/GCE. Cyclic voltammetric investigation of the electrochemical behavior of salbutamol sulfate at the polymer modified glassy carbon unveiled electrocatalytic activity of the modifier towards irreversible oxidation of salbutamol sulfate. Dependence of peak current predominantly on scan rate than on square root of scan rate, and peak potential shift with pH demonstrated that oxidation of salbutamol sulfate at the polymer modified electrode follows adsorption reaction kinetics with proton participation.Under optimized solution and differential pulse voltammetric parameters, the oxidative peak current showed linear dependence on salbutamol sulfate concentration in the range 0.2 to 8 μM with method detection limit (3s/m and determination coefficient (R2 of 6.8 × 10−8 M and 0.99786, respectively. Low method detection limit, relatively wide linear range, and recovery results of spiked standard salbutamol sulfate in syrup samples in the range 96.7–98.9% validated the method for determination of salbutamol sulfate in pharmaceutical formulations.Differential pulse voltammetric analysis of salbutamol sulfate syrup formulation for its salbutamol sulfate content revealed 98.8 to 99.3% of the labeled value confirming the applicability of the developed method for determination of salbutamol sulfate in real samples. Keywords: Electrochemistry, Analytical chemistry

  10. Numerical simulation of a TLD pulsed laser-heating scheme for determination of shallow dose and deep dose in low-LET radiation fields

    International Nuclear Information System (INIS)

    Kearfott, K.J.; Han, S.; Wagner, E.C.; Samei, E.; Wang, C.-K.C.

    2000-01-01

    A new method is described to determine the depth-dose distribution in low-LET radiation fields using a thick thermoluminescent dosimeter (TLD) with a pulsed laser-heating scheme to obtain TL glow output. The computational simulation entails heat conduction and glow curve production processes. An iterative algorithm is used to obtain the dose distribution in the detector. The simulation results indicate that the method can predict the shallow and deep dose in various radiation fields with relative errors less than 20%

  11. Application of Box-Behnken designs in parameters optimization of differential pulse anodic stripping voltammetry for lead(II) determination in two electrolytes.

    Science.gov (United States)

    Yu, Xiao-Lan; He, Yong

    2017-06-05

    Box-Behnken design was advantageous to parameters optimization of differential pulse anodic stripping voltammetry (DPASV) for the analysis of lead(II) with its high efficiency and accuracy. Five Box-Behnken designs were designed and conducted in the electrolyte of 0.1 mol/L acetate buffer and 0.1 mol/L HCl without the removal of oxygen. Significant parameters and interactions in each electrolyte were found (P-value Box-Behnken designs in parameters optimization of DPASV for lead(II) determination regardless of the electrolyte kinds.

  12. Determination of Silver(I by Differential Pulse Voltammetry Using a Glassy Carbon Electrode Modified with Synthesized N-(2-Aminoethyl-4,4'-Bipyridine

    Directory of Open Access Journals (Sweden)

    Gabriel Lucian Radu

    2010-12-01

    Full Text Available A new modified glassy carbon electrode (GCE based on a synthesized N-(2-aminoethyl-4,4'-bipyridine (ABP was developed for the determination of Ag(I by differential pulse voltammetry (DPV. ABP was covalently immobilized on GC electrodes surface using 4-nitrobenzendiazonium (4-NBD and glutaraldehyde (GA. The Ag(I ions were preconcentrated by chemical interaction with bipyridine under a negative potential (−0.6 V; then the reduced ions were oxidized by differential pulse voltammetry and a peak was observed at 0.34 V. The calibration curve was linear in the concentration range from 0.05 μM to 1 μM Ag(I with a detection limit of 0.025 μM and RSD = 3.6%, for 0.4 μM Ag(I. The presence of several common ions in more than 125-fold excess had no effect on the determination of Ag(I. The developed sensor was applied to the determination of Ag(I in water samples using a standard addition method.

  13. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    Directory of Open Access Journals (Sweden)

    Ewa Jaszczak

    2017-01-01

    Full Text Available A simple and accurate ion chromatography (IC method with pulsed amperometric detection (PAD was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R>0.992. Low detection limits (LODs in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n=3 were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  14. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

    Science.gov (United States)

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100  μ g/L for urine, 5-100  μ g/L for saliva, and 3-100  μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8  μ g/L, 5.1  μ g/L, and 5.8  μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  15. METHOD FOR DETERMINATION OF THERMAL CHARACTERISTICS OF THE LAYER OF GRANULAR MEDIA WITH ELEMENTS OF PULSED THERMAL NDT

    Directory of Open Access Journals (Sweden)

    Y. V. Shokina

    2015-01-01

    Full Text Available At the Department of Food Production of Murmansk State Technical University (MSTU was developed a method of producing smoke fuel using infrared energy supply. The method provides a stable temperature pyrolysis of wood fuel is less than 400 ° C. Kinetic of the heating layer of fuel (wooden chips is affected by chip's density and moisture content. The method of calculating of the optimum modes of smoke produce, which is based on a system of differential equations of heat and mass transfer in the IR smoke generator, was previously proposed. The system of equations includes thermal characteristics (TC of the fuel layer (e.g. specific heat, thermal conductivity, thermal diffusivity. The exact definition of these characteristics affect the accuracy of the experimental calculation of optimal process conditions with use of the developed software. A definition of layer's TC by a method with elements of pulsed thermal NDT. The use of thermal imager is proposed for measuring the temperature of the irritated surface of the porous wooden chip's lawyer.

  16. Development of a microchip-pulsed electrochemical method for rapid determination of L-DOPA and tyrosine in Mucuna pruriens.

    Science.gov (United States)

    Li, Xinchun; Chen, Zuanguang; Yang, Fan; Pan, Jianbin; Li, Yinbao

    2013-05-01

    L-3,4-dihydroxyphenylalanine (L-DOPA) is a well-recognized therapeutic compound to Parkinson's disease. Tyrosine is a precursor for the biosynthesis of L-DOPA, both of which are widely found in traditional medicinal material, Mucuna pruriens. In this paper, we described a validated novel analytical method based on microchip capillary electrophoresis with pulsed electrochemical detection for the simultaneous measurement of L-DOPA and tyrosine in M. pruriens. This protocol adopted end-channel amperometric detection using platinum disk electrode on a homemade glass/polydimethylsiloxane electrophoresis microchip. The background buffer consisted of 10 mM borate (pH 9.5) and 0.02 mM cetyltrimethylammonium bromide, which can produce an effective resolution for the two analytes. In the optimal condition, sufficient electrophoretic separation and sensitive detection for the target analytes can be realized within 60 s. Both tyrosine and L-DOPA yielded linear response in the concentration range of 5.0-400 μM (R(2) > 0.99), and the LOD were 0.79 and 1.1 μM, respectively. The accuracy and precision of the established method were favorable. The present method shows several merits such as facile apparatus, high speed, low cost and minimal pollution, and provides a means for the pharmacologically active ingredients assay in M. pruriens. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Determination of free cisplatin in medium by differential pulse polarography after ultrasound and cisplatin treatment of a cancer cell culture

    International Nuclear Information System (INIS)

    Bernard, Vladan; Skorpikova, Jirina; Mornstein, Vojtech; Fojt, Lukas

    2011-01-01

    The in vitro study was carried out for detection of the cisplatin in free form and in culture medium, depending on various conditions of sonodynamic human ovarian cancer cells A2780 treatment by differential pulse polarography (DPP). For sonodynamic treatment, we used cisplatin alone and combined cisplatin/ultrasound treatments. The ultrasound exposure intensity of 1.0 and 2.0 Wcm 2 in far field for incubation periods 1, 24 and 48 h was used. The parameters of DPP measurements were - 1 s drop time, 5 mV.s -1 voltage scan rate, 50 mV modulation amplitude and negative scanning direction; platinum wire served as counter electrode and Ag|AgCl|3 M KCI as reference electrode. The results showed the dependence of free platinum quantities in culture medium on incubation time and treatment protocol. We found difference in concentration of free cisplatin between conventional application of cisplatin and sonodynamic treatment. The sonodynamic combined treatment of cisplatin and ultrasound field showed a higher cisplatin content in the culture medium than cisplatin treatment alone; a difference of 20% was observed for incubation time 48 h. The results also showed the influence of a time sequence of ultrasound and cytostatics in the sonodynamic treatment. The highest amount of free cisplatin in the solution was found for primary application of cisplatin and the subsequent ultrasound exposure. The quantity of free cisplatin increased with time, namely for time intervals 1-24 h. There was no difference between the DPP signal of cisplatin in reaction mixture containing cells in small quantities and micro-filtered mixture without cells. Thus, the DPP method is suitable for the detection and quantification of free cisplatin in the culture medium of cell suspension. Ultrasound field can be important factor during cytostatic therapy. (author)

  18. The pulsed neutron method applied to the determination of the nuclear constants of graphite (1961); La methode des neutrons pulses appliquee a la determination des constantes nucleaires du graphite (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Lalande, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-07-01

    A method for determining the nuclear constants {sigma}{sub a} and {lambda}{sub t} of a moderator is described. The disappearance of a burst of neutrons introduced into a finite medium is studied as a function of time. This decrease in the thermal neutron density is the product of two exponentials; one representing the absorption, the other the leakage. By varying one or other of these factors, the constants of the factor left unvaried can be determined, and from this the nuclear constant values are deduced. (author) [French] On decrit une methode permettant de determiner les constantes nucleaires {sigma}{sub a} et {lambda}{sub t} d'un moderateur. On etudie la decroissance dans le temps d'une bouffee de neutrons introduite dans un milieu fini. Cette decroissance de la densite en neutrons thermiques est le produit de deux exponentielles; l'une represente l'absorption, l'autre les fuites. Par variation de l'un ou l'autre de ces facteurs, on determine les constantes du facteur laisse invariant dont on deduit les valeurs des constantes nucleaires. (auteur)

  19. Polytetrafluorethylene film-based liquid-three phase micro extraction coupled with differential pulse voltammetry for the determination of atorvastatin calcium.

    Science.gov (United States)

    Ensafi, Ali A; Khoddami, Elaheh; Rezaei, Behzad

    2013-01-01

    In this paper, we describe a new combination method based on polytetrafluorethylene (PTFE) film-based liquid three-phase micro extraction coupled with differential pulse voltammetry (DPV) for the micro extraction and quantification of atorvastatin calcium (ATC) at the ultra-trace level. Different factors affecting the liquid-three phases micro extraction of atorvastatin calcium, including organic solvent, pH of the donor and acceptor phases, concentration of salt, extraction time, stirring rate and electrochemical factors, were investigated, and the optimal extraction conditions were established. The final stable signal was achieved after a 50 min extraction time, which was used for analytical applications. An enrichment factor of 21 was achieved, and the relative standard deviation (RSD) of the method was 4.5% (n = 4). Differential pulse voltammetry exhibited two wide linear dynamic ranges of 20.0-1000.0 pmol L(-1) and 0.001-11.0 µmol L(-1) of ATC. The detection limit was found to be 8.1 pmol L(-1) ATC. Finally, the proposed method was used as a new combination method for the determination of atorvastatin calcium in real samples, such as human urine and plasma.

  20. Simultaneous determination of environmental α-radionuclides using liquid scintillation counting combined with time interval analysis (TIA) and pulse shape discrimination (PSD)

    International Nuclear Information System (INIS)

    Hashimoto, T.; Sato, K.; Yoneyama, Y.; Fukuyama, N.

    1997-01-01

    Some improvements of the detection sensitivity in pulse time interval analysis (TIA) based on selective extraction of successively α-α correlated decay events within millisecond order from random or background events, were established by the utilization of PSD, to reject β/γ-pulses from α-ones and a simple chemical procedure of radium separation, together with the use of well resolved scintillator. By applying the PSD, the contribution of β-decay events was completely eliminated in both the α-spectra and the TIA distribution curves as well as the improvement into clear energy resolution and the enhancement of detection sensitivity for the TIA. As a result, the TIA and α-spectrometric analysis of 226 Ra-extract showed the existence of 223 Ra (Ac-series) and β/α-correlated events with correlated life (due to 0.16 ms due to 214 Bi(β)-> 214 Po(α)->) along with a singly well resolved α-peak to be useful for the determination of 226 Ra (U-series). The difference of half-lives (145 and 1.78 ms) due to 216 Po and 215 Po (direct daughters of 224 Ra for Th-series and 223 Ra for Ac-series, respectively) was also proven for the possibility of the simultaneous determination of both correlated events by using the TIA/PSD combined with chemical separation and liquid scintillation counting method. Finally, the simultaneous determination of three natural decay series, which include U-, Th- and Ac-series nuclides, have been conveniently carried out for some environmental samples using the present method combined with 225 Ra yield tracer (Np-series). (author)

  1. Progress report on the analytical determination of Ag2+

    International Nuclear Information System (INIS)

    Van Alsenoy, V.

    1997-01-01

    The strong oxidising properties of Ag 2+ have been used in the chemical and nuclear industry to destroy organic waste. We aim to apply the process on radioactive graphite, organic resins and effluents. The reaction mechanisms have been studied, taking into account the thermodynamic and kinetic properties of the different reactions involved. For the experimental analysis of these reactions, the accurate analytical determination of all species involved, including Ag 2+ , is needed. The results of a systematic study of the volumetric quantification of Ag 2+ using Tl + and BrO 3 - , and of the spectrophotometric and polarographic quantification of Ag + and Ag 2+ are described. The influence of the nitric acid during the quantification of Tl + by titration with KBrO 3 is investigated and the optimal analytical conditions for our purposes were determined. The best analytical results were obtained when the titration was carried out with maximum 3 M HNO 3 and 0.5 M NaCl. When those conditions are used, the determination is accurate and reproducible. The prepared Ag 2+ solutions were analysed for Ag + using polarography with a platinum electrode. The benefits and the limitation of the polarographic measurement of Ag + using a platinum electrode are described. An indirect measurement was performed by the determination of Ce 4+ after reaction with Ce 3+ . The produced Ce 4+ was measured by direct spectrophotometry. In the future, the quantification of Ag 2+ by measuring the Ce 4+ concentration produced by the reaction with Ce 3+ , will also be verified using potentiometric titration with Fe 2+ . Ag 2+ can also be determined by the direct spectrophotometry. There is a region in which the absorbance of Ag 2+ changes linearly with the concentration. Further evaluation of the titrimetric, spectrophotometric and polarographic methods will continue, until two methods give comparable Ag 2+ concentrations, beginning with the potentiometric titration of Ce 4+ with Fe 2+

  2. Electrochemical behaviour of cadmium in the H{sub 2}O-D{sub 2}O system. I. Polarographic study

    Energy Technology Data Exchange (ETDEWEB)

    Alonso-Lopez, J

    1966-07-01

    The diffusion current of Cd{sup 2} in a H{sub 2}O-D{sub 2}O system with a supporting electrolyte of 0.1 M KC1 + 0.01 M HC1 has been studied as a function of parameters such as time, height of the mercury reservoir and electrolyte temperature. the characteristics of the process are those of a reversible diffusion-controlled process. In the H{sub 2}O-D{sub 2}O system, the values of the diffusion current were smaller than the corresponding ones in H{sub 2}O, at 25 degree centigrade. The decrease was proportional to D{sub 2}O concentration when this was greater than 35 per cent. This fact may be used as an analytical means of determining D{sub 2}O in H{sub 2}O mixtures. (Author) 7 refs.

  3. Thickness determination of large-area films of yttria-stabilized zirconia produced by pulsed laser deposition

    DEFF Research Database (Denmark)

    Pryds, N.; Christensen, Bo Toftmann; Bilde-Sørensen, Jørgen

    2006-01-01

    of the attenuation for various values of film thickness with the program CASINO. These results have been compared with direct measurements in the SEM of the film thickness on a cross-section on one of the wafers. The results of these measurements demonstrate the ability of this technique to accurately determine...

  4. Determination of trace amounts of indium in some sediments by means of coprecipitation with zirconium hydroxide and differential pulse anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Yoshimura, Wataru; Uzawa, Atushi; Hong Luxin.

    1994-01-01

    Indium in some sediments was determined by means of coprecipitation and differential pulse anodic stripping voltammetry. The analytical procedure was as follows. Fifty milliliters of distilled water is added to 10 ml of sample solution containing 0.04 g of sediment. Then, constant amounts of indium standard solution and 1 ml of zirconium oxychloride solution are added and the pH adjusted to 8.8 with ammonia water (1:2). The precipitate is separated by filtration and then dissolved in 25 ml of 4 M hydrochloric acid. After 1 ml of 5% KCNS solution is added, this solution is diluted to 50 ml with distilled water. A portion of this solution is employed for the determination of indium. After bubbling nitrogen gas through the sample solution for 100 s it was pre-electrolyzed for 100 s. The potential was scanned from -0.9 V to -0.3 Vυs. SCE for dissolution of indium ion. Indium ion was determined from the peak current of the voltammogram. The results are as follows: (1) Zirconium hydroxide was the most effective collector of indium when the pH was adjusted to 8.8 with ammonia water (1:2). (2) Iron (III) and cadmium ions were found to interfere with the determination of indium. (3) The analytical procedure took about 90 min and 0.01 ppm of indium in sample solution could be determined. (4) This method is applicable to the determination of indium in river bottom and sea floor sediment. (author)

  5. Determining optimal torsional ultrasound power for cataract surgery with automatic longitudinal pulses at maximum vacuum ex vivo.

    Science.gov (United States)

    Ronquillo, Cecinio C; Zaugg, Brian; Stagg, Brian; Kirk, Kevin R; Gupta, Isha; Barlow, William R; Pettey, Jeff H; Olson, Randall J

    2014-12-01

    To determine the optimal longitudinal power settings for Infiniti OZil Intelligent Phaco (IP) at varying torsional amplitude settings; and to test the hypothesis that increasing longitudinal power is more important at lower torsional amplitudes to achieve efficient phacoemulsification. Laboratory investigation. setting: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. procedure: Individual porcine nuclei were fixed in formalin, then cut into 2.0 mm cubes. Lens cube phacoemulsification was done using OZil IP at 60%, 80%, and 100% torsional amplitude with 0%, 10%, 20%, 30%, 50%, 75%, or 100% longitudinal power. All experiments were done using a 20 gauge 0.9 mm bent reverse bevel phaco tip at constant vacuum (550 mm Hg), aspiration rate (40 mL/min), and bottle height (50 cm). main outcome measure: Complete lens particle phacoemulsification (efficiency). Linear regression analysis showed a significant increase in efficiency with increasing longitudinal power at 60% torsional amplitude (R(2) = 0.7269, P = .01) and 80% torsional amplitude (R(2) = 0.6995, P = .02) but not at 100% amplitude (R(2) = 0.3053, P = .2). Baseline comparison of 60% or 80% vs 100% torsional amplitude without longitudinal power showed increased efficiency at 100% (P = .0004). Increasing longitudinal power to 20% abolished the efficiency difference between 80% vs 100% amplitudes. In contrast, 75% longitudinal power abolished the efficiency difference between 60% vs 100% torsional amplitudes. Results suggest that longitudinal power becomes more critical at increasing phacoemulsification efficiencies at torsional amplitudes less than 100%. Increasing longitudinal power does not further increase efficiency at maximal torsional amplitudes. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD)

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, Manuel [Universite de Pau et des Pays de L' Adour, Laboratoire de Chimie Analytique, LCABIE, UMR CNRS 5034, Pau (France); Pontificia Universidad Catolica de Valparaiso, Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Valparaiso (Chile); Lespes, Gaetane; Gautier, Martine Potin [Pontificia Universidad Catolica de Valparaiso, Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Valparaiso (Chile); Gregori, Ida de; Pinochet, Hugo [Universite de Pau et des Pays de L' Adour, Laboratoire de Chimie Analytique, LCABIE, UMR CNRS 5034, Pau (France)

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 {mu}m PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L{sup -1} in water and close to ng (Sn) kg{sup -1} in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices. (orig.)

  7. Differential pulse adsorptive stripping voltammetric determination of nanomolar levels of atorvastatin calcium in pharmaceutical and biological samples using a vertically aligned carbon nanotube/graphene oxide electrode.

    Science.gov (United States)

    Silva, Tiago Almeida; Zanin, Hudson; Vicentini, Fernando Campanhã; Corat, Evaldo José; Fatibello-Filho, Orlando

    2014-06-07

    A novel vertically aligned carbon nanotube/graphene oxide (VACNT-GO) electrode is proposed, and its ability to determine atorvastatin calcium (ATOR) in pharmaceutical and biological samples by differential pulse adsorptive stripping voltammetry (DPAdSV) is evaluated. VACNT films were prepared on a Ti substrate by a microwave plasma chemical vapour deposition method and then treated with oxygen plasma to produce the VACNT-GO electrode. The oxygen plasma treatment exfoliates the carbon nanotube tips exposing graphene foils and inserting oxygen functional groups, these effects improved the VACNT wettability (super-hydrophobic) which is crucial for its electrochemical application. The electrochemical behaviour of ATOR on the VACNT-GO electrode was studied by cyclic voltammetry, which showed that it underwent an irreversible oxidation process at a potential of +1.08 V in pHcond 2.0 (0.2 mol L(-1) buffer phosphate solution). By applying DPAdSV under optimized experimental conditions the analytical curve was found to be linear in the ATOR concentration range of 90 to 3.81 × 10(3) nmol L(-1) with a limit of detection of 9.4 nmol L(-1). The proposed DPAdSV method was successfully applied in the determination of ATOR in pharmaceutical and biological samples, and the results were in close agreement with those obtained by a comparative spectrophotometric method at a confidence level of 95%.

  8. Determination of picomolar silver concentrations by differential pulse anodic stripping voltammetry at a carbon paste electrode modified with phenylthiourea-functionalized high ordered nanoporous silica gel

    International Nuclear Information System (INIS)

    Javanbakht, Mehran; Divsar, Faten; Badiei, Alireza; Fatollahi, Fatemeh; Khaniani, Yeganeh; Ganjali, Mohammad Reza; Norouzi, Parviz; Chaloosi, Marzieh; Ziarani, Ghodsi Mohammadi

    2009-01-01

    This study introduces the design of an anodic stripping voltammetric (ASV) method for the silver ion determination at a carbon paste electrode (CPE), chemically modified with phenylthiourea-nanoporous silica gel (Tu-SBA-15-CPE). The electroanalytical pro includes two steps: preconcentration of metal ions at an electrode surface, followed by quantification of the accumulated species by differential pulse anodic stripping voltammetric methods. Factors affecting the performance of the anodic stripping were investigated, including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The most sensitive and reliable electrode contained 10% Tu-SBA-15 and 90% carbon paste. The accumulation potential and time were set at, -200 mV and 300 s, respectively, and the scan rate at 50 mV s -1 in the scan range of -200 to 700 mV. The resulting electrode demonstrated a linear response over range of silver ion concentration of 8.0-80 pmol/L with detection limit (S/N = 3) of 5 pmol/L. The prepared electrodes were used for the silver determination in sea and tap water samples and very good recovery results were obtained. The accuracy was assessed through recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry.

  9. Determination of picomolar silver concentrations by differential pulse anodic stripping voltammetry at a carbon paste electrode modified with phenylthiourea-functionalized high ordered nanoporous silica gel

    Energy Technology Data Exchange (ETDEWEB)

    Javanbakht, Mehran [Department of Chemistry, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Nano Science and Technology Research Center, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)], E-mail: mehranjavanbakht@gmail.com; Divsar, Faten [Department of Chemistry, University of Tarbiat Moallem, Tehran (Iran, Islamic Republic of); Badiei, Alireza [School of Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of); Fatollahi, Fatemeh [Department of Chemistry, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Khaniani, Yeganeh [School of Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of); Ganjali, Mohammad Reza; Norouzi, Parviz [Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Chaloosi, Marzieh [Department of Chemistry, University of Tarbiat Moallem, Tehran (Iran, Islamic Republic of); Ziarani, Ghodsi Mohammadi [Department of Chemistry, University of Alzahra, Tehran (Iran, Islamic Republic of)

    2009-09-30

    This study introduces the design of an anodic stripping voltammetric (ASV) method for the silver ion determination at a carbon paste electrode (CPE), chemically modified with phenylthiourea-nanoporous silica gel (Tu-SBA-15-CPE). The electroanalytical pro includes two steps: preconcentration of metal ions at an electrode surface, followed by quantification of the accumulated species by differential pulse anodic stripping voltammetric methods. Factors affecting the performance of the anodic stripping were investigated, including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The most sensitive and reliable electrode contained 10% Tu-SBA-15 and 90% carbon paste. The accumulation potential and time were set at, -200 mV and 300 s, respectively, and the scan rate at 50 mV s{sup -1} in the scan range of -200 to 700 mV. The resulting electrode demonstrated a linear response over range of silver ion concentration of 8.0-80 pmol/L with detection limit (S/N = 3) of 5 pmol/L. The prepared electrodes were used for the silver determination in sea and tap water samples and very good recovery results were obtained. The accuracy was assessed through recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry.

  10. Application of different methodologies in the preparation of organic matrices for determination of trace elements by differential pulse anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Sisti, Cristina

    2001-01-01

    The determination of trace elements in food samples is of great importance for the human health, considering the factors of essentiality and toxicity. On the other hand, the chemical analysis is largely affected for the steps of sample preparation; laboratory contamination of the sample and the reagents or still volatilization and losses of the elements. If these parameters are not controlled the achieved precision and accuracy could be low. In this work, the content of zinc, cadmium, lead and copper was determined in adults diet samples collected by duplicate portion technique and bovine liver, applying the differential pulse anodic stripping voltametry - (DP-ASV) technique. In the digestion of the matrices in acid medium, conventional methodologies were used, conductive heating in open recipients and equipment with microwaves source in open and closed vessels. The best procedure was the sample digestion by microwaves, in closed vessels and the other treatments made in controlled atmosphere with hood laminar-airflow class 100. The established methodology was validated with the use of a certified sample as reference (NIST - bovine liver 1577b). (author)

  11. Conformational changes in DNA caused by DNA-ase I, gamma and ultraviolet radiation as revealed by differential pulse polarography

    International Nuclear Information System (INIS)

    Vorlickova, M.

    1979-01-01

    The height, potential and half width of differential pulse-polarographic peaks of DNA were investigated in dependence on degradation by DNA-ase I and gamma and UV radiation. It was found that in all cases studied growth of peak II (reflecting conformational changes in the DNA double helix) was limited, and only after it reached a certain height further degradation induced the appearance of peak III of single-stranded DNA. This course is explained as reflecting the limited extent of conformational changes in the framework of the double helix, which probably follows from a limited number of sites that can undergo certain types of conformational changes. The character of the conformational changes is dependent on the chemical nature of the damage. (author)

  12. Rapid thermal pulse annealing

    International Nuclear Information System (INIS)

    Miller, M.G.; Koehn, B.W.; Chaplin, R.L.

    1976-01-01

    Characteristics of recovery processes have been investigated for cases of heating a sample to successively higher temperatures by means of isochronal annealing or by using a rapid pulse annealing. A recovery spectra shows the same features independent of which annealing procedure is used. In order to determine which technique provides the best resolution, a study was made of how two independent first-order processes are separated for different heating rates and time increments of the annealing pulses. It is shown that the pulse anneal method offers definite advantages over isochronal annealing when annealing for short time increments. Experimental data by means of the pulse anneal techniques are given for the various substages of stage I of aluminium. (author)

  13. Set-up of polarographic analytical methods in the framework of nuclear reactor dismantling en of the decontamination of metallic pieces

    International Nuclear Information System (INIS)

    Poirier, S.; Rahier, A.

    1996-06-01

    Differential pulse polarography has been used to measure several chemical species, relevant to the dismantling and the decontamination of a nuclear power reactor. First, a method which allows the determination of low concentrations of Co in stainless steels has been studied. Co 3+ is reduced in the presence of ethylenediamine at pH 7.5 at -0.47 V vs Ag/AgCl sat. A preliminary extraction of iron (and partially chromium) in diethylether is required. Interferences with iron and nickel have been completely eliminated without using any precipitation technique. Some complications may result from the precipitation of residual Cr 3+ in the presence of EDA, even when fluorides are added. Next, the measurements of the main components of steels have been carried out successfully. The reduction of CrO 4 2- is observed at -0.46 V vs Ag/AgCl sat. in a medium containing 0.1 M KOH, 0.5 M citric acid and 1 M NH 3 . Adding dimethylglyoxime in the same medium allows to identify the reduction to Fe 2+ and Ni 2+ respectively at -1.65 and -1.13 V vs Ag/AgCl sat. Finally, the reduction to Cr 3+ is observed at -1.2 V vs Ag/AgCl sat. in an acetic buffer containing 0.1 M EDTA

  14. Electrochemical Behaviour of Tinidazole at 1,4-Benzoquinone Modified Carbon Paste Electrode and Its Direct Determination in Pharmaceutical Tablets and Urine by Differential Pulse Voltammetry

    Directory of Open Access Journals (Sweden)

    Yosef Nikodimos

    2017-01-01

    Full Text Available A simple and highly sensitive electrochemical method based on a 1,4-benzoquinone modified carbon paste electrode (1,4-BQMCPE was described for the determination of tinidazole (TDZ. In Britton Robinson buffer solution, TDZ yields well-defined irreversible reduction peak at −0.344 V on a 1,4-BQMCPE. Compared with that on a bare CPE, the reduction peak of TDZ increased significantly on the modified CPE and the effects of different parameters on the voltammetric responses were also investigated. Differential pulse voltammetric method was proposed and optimized for TDZ determination and its reductive peak current response at 1,4-BQMCPE was found to show linear dependence on the concentration of TDZ in the range of 1.0 × 10−6 to 5.0 × 10−4 M with a linear regression equation, correlation coefficient, limit of detection (LOD, and limit of quantification (LOQ of IPC (μA = 0.19958 + 0.02657C (μM, 0.99486, 1.10 × 10−7 M, and 3.77 × 10−7, respectively. Excellent recovery results for spiked TDZ in pharmaceutical tablet samples ranging within 97.44–97.51% and in urine ranging within 95.37–96.91% were observed. The selectivity of the method for TDZ was further studied in the presence of selected potential interferents and confirmed the potential applicability of the developed method for the determination of TDZ.

  15. Simultaneous determination of mycophenolate mofetil and its active metabolite, mycophenolic acid, by differential pulse voltammetry using multi-walled carbon nanotubes modified glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Madrakian, Tayyebeh, E-mail: madrakian@basu.ac.ir; Soleimani, Mohammad; Afkhami, Abbas

    2014-09-01

    A highly sensitive electrochemical sensor for the simultaneous determination of mycophenolate mofetil (MPM) and mycophenolic acid (MPA) was fabricated by multi-walled carbon nanotubes modified glassy carbon electrode (MWCNTs/GCE). The electrochemical behavior of these two drugs was studied at the modified electrode using cyclic voltammetry and adsorptive differential pulse voltammetry. MPM and MPA were oxidized at the GCE during an irreversible process. DPV analysis showed two oxidation peaks at 0.87 V and 1.1 V vs. Ag/AgCl for MPM and an oxidation peak at 0.87 V vs. Ag/AgCl for MPA in phosphate buffer solution of pH 5.0. The MWCNTs/GCE displayed excellent electrochemical activities toward oxidation of MPM and MPA relative to the bare GCE. The experimental design algorithm was used for optimization of DPV parameters. The electrode represents linear responses in the range 5.0 × 10{sup −6} to 1.6 × 10{sup −4} mol L{sup −1} and 2.5 × 10{sup −6} mol L{sup −1} to 6.0 × 10{sup −5} mol L{sup −1} for MPM and MPA, respectively. The detection limit was found to be 9.0 × 10{sup −7} mol L{sup −1} and 4.0 × 10{sup −7} mol L{sup −1} for MPM and MPA, respectively. The modified electrode showed a good sensitivity and stability. It was successfully applied to the simultaneous determination of MPM and MPA in plasma and urine samples. - Highlights: • A new modified electrochemical sensor was constructed and used. • Multiwalled carbon nanotubes were used as the modifiers. • MPM and MPA were measured simultaneously at the low levels. • The sensor was used to the determination of MPA and MPM in real samples.

  16. Determination of biogenic amines in chocolate by ion chromatographic separation and pulsed integrated amperometric detection with implemented wave-form at Au disposable electrode.

    Science.gov (United States)

    Pastore, Paolo; Favaro, Gabriella; Badocco, Denis; Tapparo, Andrea; Cavalli, Silvano; Saccani, Giovanna

    2005-12-09

    A rapid and selective cation exchange chromatographic method coupled to integrated pulsed amperometric detection (PAD) has been developed to quantify biogenic amines in chocolate. The method is based on gradient elution of aqueous methanesulfonic acid with post column addition of strong base to obtain suitable conditions for amperometric detection. A potential waveform able to keep long time performance of the Au disposable electrode was set up. Total analysis time is less than 20min. Concentration levels of dopamine, serotonin, tyramine, histamine and 2-phenylethylamine were measured, after extraction with perchloric acid from 2g samples previously defatted twice with petroleum ether. The method was used to determine the analytes in chocolate real matrices and their quantification was made with standard addition method. Only dopamine, histamine and serotonin were found in the analysed real samples. Repeatabilities of their signals, computed on their amounts in the real samples, were 5% for all of them. Repeatabilities of tyramine and phenethylamine were relative to standard additions to real samples (close to 1mg/l in the extract) and were 7 and 3%, respectively. Detection limits were computed with the 3s of the baseline noise combined with the calibration plot regression parameters. They were satisfactorily low for all amines: 3mg/kg for dopamine, 2mg/kg for tyramine, 1mg/kg for histamine, 2mg/kg for serotonin, 3mg/kg for 2-phenylethylamine.

  17. Experimental determination of EEDF and He{sub 2}{sup *} Rydberg-state density by Thomson scattering in a ns-pulsed atmospheric micro-discharge

    Energy Technology Data Exchange (ETDEWEB)

    Schregel, Christian-Georg; Luggenhoelscher, Dirk; Czarnetzki, Uwe [Institute for Plasma and Atomic Physics, Ruhr-University Bochum (Germany)

    2016-07-01

    An open question of major importance for the investigation of atmospheric micro plasmas is the shape of the EEDF. This has been addressed by using incoherent Thomson scattering as a non-invasive diagnostic. The technique has been applied to measure the temporal evolution (Δt=20 ns) of the EVDF for a pure Helium plasma between two plane molybdenum electrodes, 0.95 mm apart. The plasma is pulsed with a repetition rate of 5 kHz at 0.7 bar. Measurements were done by a 532 nm Nd:YAG laser and a triple grating spectrometer with a gated ICCD for detection. The setup allows for detection of electron energies between 0.5 eV and 12 eV with up to three orders of magnitude in the dynamic range. Additionally, time resolved optical emission spectra where recorded and the Helium metastable was density probed by laser absorption. With the different diagnostic data combined, variation of laser energy used in Thomson scattering could additionally be utilized as a probe for the absolute Helium Excimer Rydberg-state density, allowing a unique determination of absolute density values in the early stages of the afterglow. Peak electron densities of 2 . 10{sup 20} m{sup -3} with a peak electron temperature of 2 eV have been observed.

  18. Simultaneous determination of tyramine and tryptamine and their precursor amino acids by micellar liquid chromatography and pulsed amperometric detection in wines.

    Science.gov (United States)

    Gil-Agustí, M; Carda-Broch, S; Monferrer-Pons, Ll; Esteve-Romero, J

    2007-07-13

    Two biogenic amines, tryptamine and tyramine, and their precursors, tryptophan and tyrosine, were determined by a liquid chromatographic procedure. A hybrid micellar mobile phase of sodium dodecyl sulphate (SDS) and 1-propanol, a C18 column and electrochemical detection were used. A pH study in the range of 3-9 was performed and pH 3 was finally selected in accordance with resolution and analysis time. Oxidation potential was also checked in the range 0.6-0.9V: the maximum area obtained in all those potentials was at 0.8V, which was selected to carry out the analysis using a sequence of pulsed amperometric detection waveform. The four compounds were resolved using a mobile phase of 0.15M SDS-5% 1-propanol with an analysis time of 16 min. Repeatabilities and intermediate precision were evaluated at three different concentrations for each compound with RSD values lower than 2.6 and 4.8%, respectively. Limits of detection and quantification were also obtained within the 10-40 and 33-135 ng/ml ranges, respectively. Finally, the applicability of the procedure was tested in several types of wine and no matrix effect was observed. The possibility of direct sample introduction simplifies and greatly expedites the treatments with reduced cost, improving the accuracy of the procedures.

  19. Factors affecting the simultaneous determination of copper, lead, cadmium, and zinc concentrations in human head hair using differential pulse anodic stripping voltammetry method

    International Nuclear Information System (INIS)

    Wandiga, S.O.; Jumba, I.O.

    1982-01-01

    Conditions of analysis of copper, lead, cadmium and zinc content in human hair using differential pulse anodic stripping voltammetry (DPASV) and hanging mercury drop electrode (HMDE) have been established. Sample digestion using using the mixture HCI; H 2 O 2 ;HNO 3 in the ratio 2:1:40 by volume gave the best wet-ashing procedure. The peak currents and peak potentials of zinc, cadmium and lead, copper were maximum at pH 6-7 and 1-3 respectively, when excess H 2 O 2 was eliminated with subsequent addition of hydroxyamine hydrochloride. Matrix concentration effects were minimized by digesting weights not exceeding 50 mg per sample. The effect of selenium (IV) was negligible and was ignored. The detection limit of 0.0036 ng/cm 3 for Cd + 2 was obtained while the values for zinc, lead and copper were 0.0230, 0.0287 and 0.0269 ng/cm 3 respectively at the 95% confidence limit. The observed DPASV condition of analysis of these metals are useful for routine determination of the metals in human hair and should complement the conventional flame absorption spectrophotometry method. (author)

  20. Reply to the Comment by A. Wyttenbach and L. Tobler and correction for errata on 'Minor and trace element determination of food spices and pulses of different origins by NAA and PAA'

    International Nuclear Information System (INIS)

    Miyamoto, Y.; Kajikawa, A.; Zaidi, J.H.; Nakanishi, T.; Sakamoto, K.; Kanazawa Univ.

    2001-01-01

    Reply is given to the comment by A. Wyttenbach and L. Tobler in J. Radioanal. Nucl. Chem., 247 (2001) 457 on the article by Y. Miyamoto et. al. published in J. Radioanal. Nucl. Chem. 243 (2000) 747 on 'Minor and trace element determination of food spices and pulses of different origins by NAA and PAA'. (N.T.)

  1. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  2. Determination of diffusion parameters of Thermal neutrons for non-moderator media by a pulsed method and a time independent method

    International Nuclear Information System (INIS)

    Boufraqech, A.

    1991-01-01

    Two methods for determining the diffusion parameters of thermal neutrons for non-moderator and non-multiplicator media have been developped: The first one, which is a pulsed method, is based on thermal neutrons relaxation coefficients measurement in a moderator, with and without the medium of interest that plays the role of reflector. For the experimental results interpretation using the diffusion theory, a corrective factor which takes into account the neutron cooling by diffusion has been introduced. Its dependence on the empirically obtained relaxation coefficients is in a good agreement with the calculations made in P3L2 approximation. The difference between linear extrapolation lengths of the moderator and the reflector has been taken into account, by developping the scalar fluxes in Bessel function series which automatically satisfy the boundary conditions at the extra-polated surfaces of the two media. The obtained results for Iron are in a good agreement with those in the literature. The second method is time independent, based on the 'flux albedo' measurements interpretation (Concept introduced by Amaldi and Fermi) by P3 approximation in the one group trans-port theory. The independent sources are introduced in the Marshak boundary conditions. An angular albedo matrix has been used to deal with multiple reflections and to take into account the distortion of the current vector when entring a medium, after being reflected by this latter. The results obtained by this method are slightly different from those given in the literature. The analysis of the possible sources causing this discrepancy, particulary the radial distribution of flux in cylindrical geometry and the flux depression at medium-black body interface, has shown that the origin of this discrepancy is the neutron heating by diffusion. 47 figs., 20 tabs., 39 refs. (author)

  3. Simultaneous Determination of Copper, Lead, and Cadmium Ions at a Mo6S9-xIx Nanowires Modified Glassy Carbon Electrode Using Differential Pulse Anodic Stripping Voltammetry

    International Nuclear Information System (INIS)

    Lin, Hong; Li, Meixian; Mihailovič, Dragan

    2015-01-01

    Highlights: • An electrochemical sensor based on Mo 6 S 9-x I x nanowires was constructed. • Mo 6 S 9-x I x nanowires can amplify electrochemical responses of heavy metal ions. • Mo 6 S 9-x I x nanowires can promote electron transfer. • Mo 6 S 9-x I x nanowires can accumulate metal ions due to large surface area. • The preparation of the sensor is simple, short-time and it does not require a special apparatus. -- ABSTRACT: A novel electrochemical sensor based on a new kind of nanomaterials Mo 6 S 9-x I x nanowires modified glassy carbon electrode (GCE) was constructed for simultaneous determination of cadmium(II), lead(II) and copper(II) using differential pulse anodic stripping voltammetry (DPASV). Various experimental parameters such as the modified amount, pH, deposition time and deposition potential were optimized. Under the optimal conditions, the stripping peak currents increase linearly with increasing concentrations of Cd(II), Pb(II) and Cu(II) ions in the ranges of 0.5∼150 μg · L −1 , 1.5∼450 μg · L −1 and 0.8~240 μg · μg·L −1 , 1.5∼450 μg·L −1 and 0.8∼240 μg·L −1 , respectively. And the limits of detection (S/N = 3) are estimated to be 0.10 μg · L −1 for Cd (II), 0.45 μg·L −1 for Pb(II) and 0.20 μg·L −1 for Cu(II), which are two orders of magnitude lower than those obtained at the unmodified electrodes. Most importantly, the sensor has been successfully applied to the determination of trace metal ions in the tap water samples. This developed electrochemical sensor exhibits high sensitivity, good stability and reproducibility

  4. Validated high-performance anion-exchange chromatography with pulsed amperometric detection method for the determination of residual keratan sulfate and other glucosamine impurities in sodium chondroitin sulfate.

    Science.gov (United States)

    Bottelli, Susanna; Grillo, Gianluca; Barindelli, Edoardo; Nencioni, Alessandro; Di Maria, Alessandro; Fossati, Tiziano

    2017-07-07

    An efficient and sensitive analytical method based on high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) was devised for the determination of glucosamine (GlcN) in sodium chondroitin sulfate (CS). Glucosamine (GlcN) is intended as marker of residual keratan sulfate (KS) and other impurities generating glucosamine by acidic hydrolyzation. The latter brings CS and KS to their respective monomers. Since GlcN is present only in KS we developed a method that separates GlcN from GalN, the principal hydrolytic product of CS, and then we validated it in order to quantify GlcN. Method validation was performed by spiking CS raw material with known amounts of KS. Detection limit was 0.5% of KS in CS (corresponding to 0.1μg/ml), and the linear range was 0.5-5% of KS in CS (corresponding to 0.1-1μg/ml). The optimized analysis was carried out on an ICS-5000 system (Dionex, Sunnyvale, CA, USA) equipped with a Dionex Amino Trap guard column (3mm×30mm), Dionex CarboPac-PA20 (3mm×30mm) and a Dionex CarboPac-PA20 analytical column (3mm×150mm) using gradient elution at a 0.5ml/min flow rate. Regression equations revealed good linear relationship (R 2 =0.99, n=5) within the test ranges. Quality parameters, including precision and accuracy, were fully validated and found to be satisfactory. The fully validated HPAEC-PAD method was readily applied for the quantification of residual KS in CS in several raw materials and USP/EP reference substance. Results confirmed that the HPAEC-PAD method is more specific than the electrophoretic method for related substance reported in EP and provides sensitive determination of KS in acid-hydrolyzed CS samples, enabling the quantitation of KS and other impurities (generating glucosamine) in CS. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Pulsed power

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The key element of our pulsed power program is concentration of power in time and space by suppression of breakdown in dielectrics and in vacuum. Magnetically insulated vacuum transmission lines and magnetic suppression of insulator flashover have continued as the main reserch directions. Vacuum insulated line studies at Physics International have been expanded and a test bed at Sandia, called MITE (Magnetically Insulated Transmission Experiment), is under development. The choice for the baseline EBFA design will depend on the outcome of these studies and should be made in July 1977. The slow and intermediate speed pulsed power approaches to EBFA will be based on Proto I and Proto II results and several of the projected EBFA subsystems are presently being tested in Proto II. A further stage of power concentration, within the vacuum diode itself, would considerably ease the burden on dielectrics; methods of power multiplication involving magnetically imploded plasmas are being considered and tests have begun using the Ripple III apparatus

  6. Pulsed ventilation in mines. II

    Energy Technology Data Exchange (ETDEWEB)

    Krause, D

    1975-06-01

    Using test results, an attempt is made to determine the form of the free jet and to derive design data for pulsed fans. The most suitable placing of these fans for the ventilation of headings is discussed.

  7. Loudness of tone pulses in a free field

    DEFF Research Database (Denmark)

    Poulsen, Torben

    1981-01-01

    Investigations of temporal loudness summation of tone pulses have been performed. The investigations comprised equal loudness determinations between pairs of tone pulses with a duration ratio of 1:2, and threshold determinations of the same tone pulses. Pulse durations ranged from 5 to 640 ms...

  8. Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values'

    DEFF Research Database (Denmark)

    Hansen, Tine Willum

    2010-01-01

    Carotid-femoral pulse wave velocity (PWV), a direct measure of aortic stiffness, has become increasingly important for total cardiovascular (CV) risk estimation. Its application as a routine tool for clinical patient evaluation has been hampered by the absence of reference values. The aim of the ...

  9. Pulse radiolysis of gases

    International Nuclear Information System (INIS)

    Nielsen, O.J.

    1984-04-01

    The pulse radiolysis equipment and technique are described and its relevance to atmospheric chemistry is discussed. Pulse radiolysis of a number of different chemical systems have been used to check the validity of the proposed mechanisms: 1) The hydrogen atom yield in the pulse radiolysis of H 2 was measured by four independent calibration techniques, using reactions of H with O 2 , C1NO, and HI. The H atom yield was compared with O 2 yields in pure O 2 and in O 2 /SF 6 mixtures which lead to a value G(H) = 17.6. The rate constants at room temperature of several reactions were determined. 2) OH radical reactions with tetraalkyllead at room temperature and with ethane, methane, and a series of C1- and F-substituted methanes at 300-400 K were studied. Arrhenius parameters, A and Esub(a), were determined for several reactions. The lifetime of Pb(CH 3 ) 4 and Pb(C 2 H 5 ) 4 in ambient air is estimated. CF 2 C1 2 was found to be a very efficient third body, M, in the reaction OH + OH + M arrow H 2 O 2 + M. 3) In the H 2 S systems the HS extinction coefficient at 3242 AA was determined to 9.5 x 10 2 cm -1 mol -1 . Four rate constants at room temperature were determined. (author)

  10. A digital long pulse integrator

    International Nuclear Information System (INIS)

    Broesch, J.D.; Strait, E.J.; Snider, R.T.

    1996-10-01

    A prototype digital integrator with very long integration capabilities has been developed and field tested on an inductive magnetic sensor on the DIII-D Tokamak. The integrator is being developed for use on ITER with a pulse length of 1000 s, and has direct applications for other long pulse Tokamaks. Inductive magnetic sensors are routinely used on existing Tokamaks, are well understood, and are extremely robust, however, they require integration of the signal to determine the magnetic field strength. The next generation of Tokamaks, will have pulse lengths of 1000 s or longer, require integrators with drift and noise characteristics compatible with the very long pulse lengths. This paper will discuss the architecture, algorithms, and programming of the Long Pulse Integrator (LPI). Of particular interest are the noise control and the built-in offset correction techniques used in this application

  11. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  12. Pulse radiolysis

    International Nuclear Information System (INIS)

    Greenshields, H.; Seddon, W.A.

    1982-03-01

    This supplement to two bibliographies published in 1970 and 1972 lists 734 references to the literature of pulse radiolysis, arranged under eight broad subject headings. The references were compiled by searching Biological Abstracts, Chemical Abstracts, Nuclear Science Abstracts and the Weekly List of Papers in Radiation Chemistry issued by the Radiation Chemistry Data Center of Notre Dame University. Full bibliographic data is given for papers published in the period 1971 to 1974. A personal author index listing more than 600 authors and a similar number of co-authors is included

  13. Pulse pile-up. I: Short pulses

    International Nuclear Information System (INIS)

    Wilkinson, D.H.

    1990-07-01

    The search for rare large pulses against an intense background of smaller ones involves consideration of pulse pile-up. Approximate methods are presented, based on ruin theory, by which the probability of such pile-up may be estimated for pulses of arbitrary form and of arbitrary pulse-height distribution. These methods are checked against cases for which exact solutions are available. The present paper is concerned chiefly with short pulses of finite total duration. (Author) (5 refs., 24 figs.)

  14. Taking the pulse of the Mediterranean

    International Nuclear Information System (INIS)

    Osterberg, C.

    1977-01-01

    The staff at the International Laboratory of Marine Radioactivity in Monaco realized that they were favourably located to ?take the pulse of the Mediterranean? and begin an enquiry into its health. Practically all of the radioactivity in the water and sediments could be attributed to world-wide fallout from the nuclear tests of the 1960's. Unable to find enough radioactivity in the Mediterranean to work with in a meaningful way, the laboratory imported sediments from the Bikini-Eniwetok sites of the American thermonuclear tests, and sediments from the Irish Sea near the Windscale effluent pipe to do their experiments. Other experiments were carried out with relatively innocuous, short half-lived 237 Pu, made especially for the laboratory in Japan and in the USA. A proposal was made to the United Nations Environment Programme (UNEP) to monitor the levels of chlorinated hydrocarbons and heavy elements in the Mediterranean. This report briefly discusses that work. Three sets of studies were carried out by the Monaco group to assess the current levels of pollutants in the Mediterranean: 1) Radioactivity; 2) Chlorinated hydrocarbons (DDT's and polychlorinated biphenyls); 3) Heavy elements. As stated earlier, measurements showed that radioactivity in the ocean off Monaco is quite low, indicating that there are no major sources of radionuclides reaching the open ocean other than fallout. Polychlorinated biphenyls were measured by gas-chromatography. The results of this study were being published (Marine Pollution Bulletin, 1977) but it can be said that the data are not much different than that for the Atlantic Ocean and Saragasso Sea. The western Mediterranean is clearly higher in PCB's than the eastern Mediterranean, but not unduly so. Less can be said about the trace or heavy elements because the patterns are so variable. Atomic absorption spectrometry is used to detect and measure most trace elements. For the lower levels that appear in seawater, chemical

  15. Drought induced pulses of SO42- from a Canadian shield wetland: use of δ34S and δ18O in SO42- to determine sources of sulfur

    International Nuclear Information System (INIS)

    Schiff, S.L.; Spoelstra, J.; Semkin, R.G.; Jeffries, D.S.

    2005-01-01

    Following summer drought periods, pulses of elevated SO 4 2- concentrations are frequently observed in streams draining forested catchments that contain wetlands. Delays in the recovery of freshwater streams and lakes in eastern Canada from historically high levels of acidic precipitation have been partially ascribed to these periodic pulses of SO 4 2- . Climate in eastern Canada has also changed within the last 25 a, with a documented increase in summer dryness and duration of droughts. In small forested catchments in the Turkey Lakes Watershed (TLW), SO 4 2- concentrations in streams draining wetlands can be elevated by up to a factor of 7 during post-drought discharge events compared to the annual average. Two neighbouring catchments, one with a series of cascading wetlands and one without any wetlands, were selected for comparison. Stable S and O isotope ratios were analyzed in samples of bulk precipitation, streams, and groundwaters to examine sources of SO 4 2- in post-drought pulses. δ 34 S-SO 4 2- in the streams and groundwaters show that SO 4 2- is retained in the wetland via SO 4 2- reduction and stored in the upper peat profile. Nitrate is elevated in soil and groundwaters at TLW due to high rates of nitrification in forest soils and the presence of NO 3 - can be used to identify piezometers unaffected by SO 4 2- reduction. δ 18 O-SO 4 2- shows that higher concentrations of SO 4 2- in deeper groundwater are likely due to oxidation of organic S and not a geologic source of reduced S. Following drought, the low δ 34 S-SO 4 2- in streams is consistent with wetland retention by SO 4 2- reduction and much lower than SO 4 2- released by weathering in deep glacial till and bedrock. High SO 4 2- groundwaters and geologic sources do not contribute to the SO 4 2- pulses in streams. Isotopic patterns over 6 a were similar. Pulses of SO 4 2- in the wetland catchments following drought are a result of the oxidation of S previously reduced and stored in the wetland

  16. Pulsed irradiation of enriched UO{sub 2} in the Annular Core Pulse Reactor (ACPR)

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, T R; Lucoff, D M; Reil, K O; Croucher, D W [Sandia Laboratories (United States)

    1974-07-01

    A series of experiments have been conducted in the Annular Core Pulse Reactor (ACPR) to determine the energy deposition and behavior of enriched UO{sub 2} under pulse conditions. In the experiment single unirradiated pellets with enrichments up to 25 percent were pulse heated to melt temperatures. Temperature and fission product inventory measurements were made and compared with neutron transport calculations. (author)

  17. Construction of Tungsten Halogen, Pulsed LED, and Combined Tungsten Halogen-LED Solar Simulators for Solar Cell I-V Characterization and Electrical Parameters Determination

    Directory of Open Access Journals (Sweden)

    Anon Namin

    2012-01-01

    Full Text Available I-V characterization of solar cells is generally done under natural sunlight or solar simulators operating in either a continuous mode or a pulse mode. Simulators are classified on three features of irradiance, namely, spectral match with respect to air mass 1.5, spatial uniformity, and temporal stability. Commercial solar simulators use Xenon lamps and halogen lamps, whereas LED-based solar simulators are being developed. In this work, we build and test seven simulators for solar cell characterization, namely, one tungsten halogen simulator, four monochromatic (red, green, blue, and white LED simulators, one multicolor LED simulator, and one tungsten halogen-blue LED simulator. The seven simulators provide testing at nonstandard test condition. High irradiance from simulators is obtained by employing elevated supply voltage to tungsten halogen lamps and high pulsing voltages to LEDs. This new approach leads to higher irradiance not previously obtained from tungsten halogen lamps and LEDs. From I-V curves, electrical parameters of solar cell are made and corrected based on methods recommended in the IEC 60891 Standards. Corrected values obtained from non-STC measurements are in good agreement with those obtained from Class AAA solar simulator.

  18. Polarographic study of the Cu(II)/Cu(I) system in the presence of 1-ascorbic acid and 0,1 M ClK; Estudio polarografico del sistema Cu(II)/Cu(I) en presencia del acido 1-ascorbico y en ClK 0,1 M

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Lopez, J

    1969-07-01

    While studying the catalytic effect of Cu{sup {down_arrow}}2 ions on the oxidation process of 1-ascorbic acid, it has been observed that, in a 0,1 M solution of K1 at a pH 6 to 7, the above acid gives rise in the presence of Cu{sup {down_arrow}}2 ions to a polarographic wave of half-wave potential of -0,41 V (vs. S.C.E.). (Author) 14 refs.

  19. Method for pulse to pulse dose reproducibility applied to electron linear accelerators

    International Nuclear Information System (INIS)

    Ighigeanu, D.; Martin, D.; Oproiu, C.; Cirstea, E.; Craciun, G.

    2002-01-01

    An original method for obtaining programmed beam single shots and pulse trains with programmed pulse number, pulse repetition frequency, pulse duration and pulse dose is presented. It is particularly useful for automatic control of absorbed dose rate level, irradiation process control as well as in pulse radiolysis studies, single pulse dose measurement or for research experiments where pulse-to-pulse dose reproducibility is required. This method is applied to the electron linear accelerators, ALIN-10 of 6.23 MeV and 82 W and ALID-7, of 5.5 MeV and 670 W, built in NILPRP. In order to implement this method, the accelerator triggering system (ATS) consists of two branches: the gun branch and the magnetron branch. ATS, which synchronizes all the system units, delivers trigger pulses at a programmed repetition rate (up to 250 pulses/s) to the gun (80 kV, 10 A and 4 ms) and magnetron (45 kV, 100 A, and 4 ms).The accelerated electron beam existence is determined by the electron gun and magnetron pulses overlapping. The method consists in controlling the overlapping of pulses in order to deliver the beam in the desired sequence. This control is implemented by a discrete pulse position modulation of gun and/or magnetron pulses. The instabilities of the gun and magnetron transient regimes are avoided by operating the accelerator with no accelerated beam for a certain time. At the operator 'beam start' command, the ATS controls electron gun and magnetron pulses overlapping and the linac beam is generated. The pulse-to-pulse absorbed dose variation is thus considerably reduced. Programmed absorbed dose, irradiation time, beam pulse number or other external events may interrupt the coincidence between the gun and magnetron pulses. Slow absorbed dose variation is compensated by the control of the pulse duration and repetition frequency. Two methods are reported in the electron linear accelerators' development for obtaining the pulse to pulse dose reproducibility: the method

  20. Random pulse generator

    International Nuclear Information System (INIS)

    Guo Ya'nan; Jin Dapeng; Zhao Dixin; Liu Zhen'an; Qiao Qiao; Chinese Academy of Sciences, Beijing

    2007-01-01

    Due to the randomness of radioactive decay and nuclear reaction, the signals from detectors are random in time. But normal pulse generator generates periodical pulses. To measure the performances of nuclear electronic devices under random inputs, a random generator is necessary. Types of random pulse generator are reviewed, 2 digital random pulse generators are introduced. (authors)

  1. Programmable pulse generator

    International Nuclear Information System (INIS)

    Xue Zhihua; Lou Binqiao; Duan Xiaohui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  2. Pulsed water jet generated by pulse multiplication

    Czech Academy of Sciences Publication Activity Database

    Dvorský, R.; Sitek, Libor; Sochor, T.

    2016-01-01

    Roč. 23, č. 4 (2016), s. 959-967 ISSN 1330-3651 R&D Projects: GA MŠk(CZ) LO1406; GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : high- pressure pulses * pulse intensifier * pulsed water jet * water hammer effect Subject RIV: JQ - Machines ; Tools Impact factor: 0.723, year: 2016 http://hrcak.srce.hr/163752?lang=en

  3. Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electro reduced graphene oxide and imidazolium groups

    International Nuclear Information System (INIS)

    Wu, Feng; Huang, Ting; Xie, Qingji; Hu, Yangjian; Yang, Xin; Ouyang, Yuejun

    2016-01-01

    A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCE ox ). Next, an imidazolium alkoxy silane (ImAS) is covalently tethered to the surface of the GCE ox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCE ox by CV yields electro reduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at −50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine. (author)

  4. Determining

    Directory of Open Access Journals (Sweden)

    Bahram Andarzian

    2015-06-01

    Full Text Available Wheat production in the south of Khuzestan, Iran is constrained by heat stress for late sowing dates. For optimization of yield, sowing at the appropriate time to fit the cultivar maturity length and growing season is critical. Crop models could be used to determine optimum sowing window for a locality. The objectives of this study were to evaluate the Cropping System Model (CSM-CERES-Wheat for its ability to simulate growth, development, grain yield of wheat in the tropical regions of Iran, and to study the impact of different sowing dates on wheat performance. The genetic coefficients of cultivar Chamran were calibrated for the CSM-CERES-Wheat model and crop model performance was evaluated with experimental data. Wheat cultivar Chamran was sown on different dates, ranging from 5 November to 9 January during 5 years of field experiments that were conducted in the Khuzestan province, Iran, under full and deficit irrigation conditions. The model was run for 8 sowing dates starting on 25 October and repeated every 10 days until 5 January using long-term historical weather data from the Ahvaz, Behbehan, Dezful and Izeh locations. The seasonal analysis program of DSSAT was used to determine the optimum sowing window for different locations as well. Evaluation with the experimental data showed that performance of the model was reasonable as indicated by fairly accurate simulation of crop phenology, biomass accumulation and grain yield against measured data. The normalized RMSE were 3%, 2%, 11.8%, and 3.4% for anthesis date, maturity date, grain yield and biomass, respectively. Optimum sowing window was different among locations. It was opened and closed on 5 November and 5 December for Ahvaz; 5 November and 15 December for Behbehan and Dezful;and 1 November and 15 December for Izeh, respectively. CERES-Wheat model could be used as a tool to evaluate the effect of sowing date on wheat performance in Khuzestan conditions. Further model evaluations

  5. Thermodynamical aspects of pulse tubes

    NARCIS (Netherlands)

    Waele, de A.T.A.M.; Steijaert, P.P.; Gijzen, J.

    1997-01-01

    The cooling power of cryocoolers is determined by the work done by the compressor and the entropy produced by the irreversible processes in the various components of the system. In this paper we discuss the thermodynamics of pulse tubes, but many of the relationships are equally valid for other

  6. Laser pulse stacking method

    Science.gov (United States)

    Moses, E.I.

    1992-12-01

    A laser pulse stacking method is disclosed. A problem with the prior art has been the generation of a series of laser beam pulses where the outer and inner regions of the beams are generated so as to form radially non-synchronous pulses. Such pulses thus have a non-uniform cross-sectional area with respect to the outer and inner edges of the pulses. The present invention provides a solution by combining the temporally non-uniform pulses in a stacking effect to thus provide a more uniform temporal synchronism over the beam diameter. 2 figs.

  7. DNA double-strand breaks in mammalian cells exposed to γ-rays and very heavy ions. Fragment-size distributions determined by pulsed-field gel electrophoresis

    International Nuclear Information System (INIS)

    Kraxenberger, F.; Friedl, A.A.; Eckardt-Schupp, F.; Weber, K.J.; Flentje, M.; Quicken, P.; Kellerer, A.M.; Ludwig-Maximilians University, Munich

    1998-01-01

    The spatial distribution of DNA double-strand breaks (DSB) was assessed after treatment of mammalian cells (V79) with densely ionizing radiation. Cells were exposed to beams of heavy charged particles (calcium ions: 6.9 MeV/u, 2.1.10 3 keV/μm; uranium ions: 9.0 MeV/u, 1.4.10 4 keV/μm) at the linear accelerator UNILAC of GSI, Darmstadt. DNA was isolated in agarose plugs and subjected to pulsed-field gel electrophoresis under conditions that separated DNA fragments of size 50 kbp to 5 Mbp. The measured fragment distributions were compared to those obtained after γ-irradiation and were analyzed by means of a convolution and a deconvolution technique. In contrast to the finding for γ-radiation, the distributions produced by heavy ions do not correspond to the random breakage model. Their marked overdispersion and the observed excess of short fragments reflect spatial clustering of DSB that extends over large regions of the DNA, up to several mega base pairs (Mbp). At fluences of 0.75 and 1.5/μm 2 , calcium ions produce nearly the same shape of fragment spectrum, merely with a difference in the amount of DNA entering the gel; this suggests that the DNA is fragmented by individual calcium ions. At a fluence of 0.8/μm 2 uranium ions produce a profile that is shifted to smaller fragment sizes in comparison to the profile obtained at a fluence of 0.4/μm 2 ; this suggests cumulative action of two separate ions in the formation of fragments. These observations are not consistent with the expectation that the uranium ions, with their much larger LET, should be more likely to produce single particle action than the calcium ions. However, a consideration of the greater lateral extension of the tracks of the faster uranium ions explains the observed differences; it suggests that the DNA is closely coiled so that even DNA locations several Mbp apart are usually not separated by less than 0.1 or 0.2 μm. (orig.)

  8. Pulse to pulse klystron diagnosis system

    International Nuclear Information System (INIS)

    Nowak, J.; Davidson, V.; Genova, L.; Johnson, R.; Reagan, D.

    1981-03-01

    This report describes a system used to study the behavior of SLAC high powered klystrons operating with a twice normal pulse width of 5 μs. At present, up to eight of the klystrons installed along the accelerator can be operated with long pulses and monitored by this system. The report will also discuss some of the recent findings and investigations

  9. THE DETERMINATION OF NON-PESTICIDAL AND PESTICIDAL ORGANOTIN COMPOUNDS IN WATER BY GAS CHROMATOGRAPHY WITH [PULSED] FLAME PHOTOMETRIC DETECTION (GS/PFPD): THE EFFECTS OF "MASS" DISCRIMINATION

    Science.gov (United States)

    Capillary gas chromatography with GC/PFPD was used in the development of analytical methodology for determining both non-pesticidal and pesticidal organotin compounds in drinking water and other aqueous matrices. The method involves aqueous ethylation of organotin analytes with ...

  10. The direct determination, by differential pulse anodic-stripping voltammetry at the thin mercury-film electrode, of cadmium, lead and copper

    International Nuclear Information System (INIS)

    Lee, A.F.

    1981-01-01

    This report describes the development and application of a voltammetric procedure for the direct, simultaneous determination of cadmium, lead, and copper in three SAROC reference materials (carbonatite, magnesite, and quartz). The electrolyte was a mixture of 1 M ammonium chloride, 0,1 M citric acid, and 0,025 M ascorbic acid. No interferences were encountered from Fe(III), As(III), Sb(V), Tl(I), or In(III) at the concentrations present in the samples. Intermetallic interferences were eliminated by the use of thin mercury-film electrodes not less than 80nm thick. Limits of detection were determined by the degree to which the supporting electrolyte could be purified, and were estimated to be 10ng/g, 250ng/g, and 150ng/g for cadmium, lead, and copper respectively

  11. The determination, by differential pulse anodic-stripping voltammetry at the thin mercury-film electrode, of cadmium and thallium in six NIMROC reference materials

    International Nuclear Information System (INIS)

    Lee, A.F.

    1981-01-01

    A previously reported procedure has been extended to include the determination of thallium. In samples where thallium occurred in the presence of relatively high concentrations of cadmium, the stripping peak for cadmium was first suppressed with non-ionic surface-active agent, Triton X-100. Cadmium and thallium were determined directly in six NIMROC reference materials without interference from iron(III), in a reducing electrolyte, which is also a complexing agent, consisting of 1 M ammonium chloride, 0,1 M citric acid, and 0,025 M ascorbic acid. Interelement interferences were eliminated by the use of a mercury-film electrode of adequate thickness. The limits of detection for cadmium were 10ng/g and those for thallium 20ng/g

  12. Rapid testing of pulse transformers

    Science.gov (United States)

    Grillo, J.

    1980-01-01

    Quality-control testing of pulse transformers is speeded up by method for determining rise time and droop. Instead of using oscilloscope and square-wave generator to measure these characteristics directly, method uses voltmeter and sine-wave generator to measure them indirectly in about one-tenth time. Droop and rise time are determined by measuring input/output voltage ratio at just four frequencies.

  13. Simultaneous determination of Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry based on graphite nanofibers-Nafion composite modified bismuth film electrode.

    Science.gov (United States)

    Li, Dongyue; Jia, Jianbo; Wang, Jianguo

    2010-12-15

    A bismuth-film modified graphite nanofibers-Nafion glassy carbon electrode (BiF/GNFs-NA/GCE) was constructed for the simultaneous determination of trace Cd(II) and Pb(II). The electrochemical properties and applications of the modified electrode were studied. Operational parameters such as deposition potential, deposition time, and bismuth ion concentration were optimized for the purpose of determination of trace metal ions in 0.10 M acetate buffer solution (pH 4.5). Under optimal conditions, based on three times the standard deviation of the baseline, the limits of detection were 0.09 μg L(-1) for Cd(II) and 0.02 μg L(-1) for Pb(II) with a 10 min preconcentration. In addition, the BiF/GNFs-NA/GCE displayed good reproducibility and selectivity, making it suitable for the simultaneous determination of Cd(II) and Pb(II) in real sample such as river water and human blood samples. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Analysis of picosecond pulsed laser melted graphite

    International Nuclear Information System (INIS)

    Steinbeck, J.; Braunstein, G.; Speck, J.; Dresselhaus, M.S.; Huang, C.Y.; Malvezzi, A.M.; Bloembergen, N.

    1986-01-01

    A Raman microprobe and high resolution TEM have been used to analyze the resolidified region of liquid carbon generated by picosecond pulse laser radiation. From the relative intensities of the zone center Raman-allowed mode for graphite at 1582 cm -1 and the disorder-induced mode at 1360 cm -1 , the average graphite crystallite size in the resolidified region is determined as a function of position. By comparison with Rutherford backscattering spectra and Raman spectra from nonosecond pulsed laser melting experiments, the disorder depth for picosecond pulsed laser melted graphite is determined as a function of irradiating energy density. Comparisons of TEM micrographs for nanosecond and picosecond pulsed laser melting experiments show that the structure of the laser disordered regions in graphite are similar and exhibit similar behavior with increasing laser pulse fluence

  15. [Pulse flows of populations of cortical neurons under low-intensity pulsed microwave: interspike intervals].

    Science.gov (United States)

    Chizhenkova, R A

    2014-01-01

    Pulse flows of populations of cortical neurons were investigated on unanesthetized nonimmobilized rabbits prior, during, and after 1-min microwave irradiation (wavelength 37.5 cm, power density 0.5-1.0 mW/cm2) in continuous and pulse-modulated modes with a frequency of 5, 20 and 100 Hz. The changes in the characteristics of interspike intervals resulted from these exposures. The peculiarity of rearrangements of pulse flows and their dynamics was determined by modes of irradiation.

  16. Determination of water-extractable nonstructural carbohydrates, including inulin, in grass samples with high-performance anion exchange chromatography and pulsed amperometric detection.

    Science.gov (United States)

    Raessler, Michael; Wissuwa, Bianka; Breul, Alexander; Unger, Wolfgang; Grimm, Torsten

    2008-09-10

    The exact and reliable determination of carbohydrates in plant samples of different origin is of great importance with respect to plant physiology. Additionally, the identification and quantification of carbohydrates are necessary for the evaluation of the impact of these compounds on the biogeochemistry of carbon. To attain this goal, it is necessary to analyze a great number of samples with both high sensitivity and selectivity within a limited time frame. This paper presents a rugged and easy method that allows the isocratic chromatographic determination of 12 carbohydrates and sugar alcohols from one sample within 30 min. The method was successfully applied to a variety of plant materials with particular emphasis on perennial ryegrass samples of the species Lolium perenne. The method was easily extended to the analysis of the polysaccharide inulin after its acidic hydrolysis into the corresponding monomers without the need for substantial change of chromatographic conditions or even the use of enzymes. It therefore offers a fundamental advantage for the analysis of the complex mixture of nonstructural carbohydrates often found in plant samples.

  17. Heat pulse propagation studies in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Fredrickson, E.D.; Callen, J.D.; Colchin, R.J.; Efthimion, P.C.; Hill, K.W.; Izzo, R.; Mikkelsen, D.R.; Monticello, D.A.; McGuire, K.; Bell, J.D.

    1986-02-01

    The time scales for sawtooth repetition and heat pulse propagation are much longer (10's of msec) in the large tokamak TFTR than in previous, smaller tokamaks. This extended time scale coupled with more detailed diagnostics has led us to revisit the analysis of the heat pulse propagation as a method to determine the electron heat diffusivity, chi/sub e/, in the plasma. A combination of analytic and computer solutions of the electron heat diffusion equation are used to clarify previous work and develop new methods for determining chi/sub e/. Direct comparison of the predicted heat pulses with soft x-ray and ECE data indicates that the space-time evolution is diffusive. However, the chi/sub e/ determined from heat pulse propagation usually exceeds that determined from background plasma power balance considerations by a factor ranging from 2 to 10. Some hypotheses for resolving this discrepancy are discussed. 11 refs., 19 figs., 1 tab.

  18. Heat pulse propagation studies in TFTR

    International Nuclear Information System (INIS)

    Fredrickson, E.D.; Callen, J.D.; Colchin, R.J.

    1986-02-01

    The time scales for sawtooth repetition and heat pulse propagation are much longer (10's of msec) in the large tokamak TFTR than in previous, smaller tokamaks. This extended time scale coupled with more detailed diagnostics has led us to revisit the analysis of the heat pulse propagation as a method to determine the electron heat diffusivity, chi/sub e/, in the plasma. A combination of analytic and computer solutions of the electron heat diffusion equation are used to clarify previous work and develop new methods for determining chi/sub e/. Direct comparison of the predicted heat pulses with soft x-ray and ECE data indicates that the space-time evolution is diffusive. However, the chi/sub e/ determined from heat pulse propagation usually exceeds that determined from background plasma power balance considerations by a factor ranging from 2 to 10. Some hypotheses for resolving this discrepancy are discussed. 11 refs., 19 figs., 1 tab

  19. Repeatability of pulse diagnosis in traditional Indian Ayurveda medicine

    DEFF Research Database (Denmark)

    Kurande, Vrinda; Waagepetersen, Rasmus; Toft, Egon

    2012-01-01

    Purpose In Ayurveda, pulse diagnosis is the unique diagnostic method that determines the proportion of diagnostic variables (vata, pitta and kapha); however, this is only justifiable if pulse diagnosis yields a consistent result. Though pulse diagnosis has a long historical use, still there is la...

  20. Sensitive determination of bismuth by flame atomic absorption spectrometry using atom trapping in a slotted quartz tube and revolatilization with organic solvent pulse

    International Nuclear Information System (INIS)

    Kılınç, Ersin; Bakırdere, Sezgin; Aydın, Fırat; Ataman, O. Yavuz

    2012-01-01

    Sensitivity of flame atomic absorption spectrometry (FAAS) for Bi determination was improved by slotted quartz tube (SQT) that was used also for atom trapping (AT). The trapped analyte was released by aspirating a small volume of organic solvent after a reasonable analyte collection time. Sensitivity was improved by 2.9 times by SQT-FAAS and 256 times by SQT-AT-FAAS with respect to FAAS. Optimum trapping period was found to be 6.0 min (36.0 mL of solution). Limit of detection (LOD) for SQT-AT-FAAS was found to be 1.6 ng mL −1 . %RSD was calculated as 4.0% for five replicate measurements of 7.5 ng mL −1 Bi by SQT-AT-FAAS. Accuracy of the method developed was checked by analyzing a standard reference material of simulated fresh water (NIST 1643e) and result found was in good agreement with the certified one. The method can be applied in any laboratory equipped with a flame AA spectrometer. The consumption of time and sample volume is fairly low and application is simple and easy.

  1. Analytical protocol for the sensitive determination of mannitol, sorbitol and glucose containing powders in pharmaceutical workplaces by ion chromatography using a pulsed amperometric detector.

    Science.gov (United States)

    Butler, Owen; Forder, James; Saunders, John

    2015-03-15

    Workers in the pharmaceutical industry can potentially be exposed to airborne dusts and powders that can contain potent active pharmaceutical ingredients (API). Occupational hygienists and health and safety professionals need to assess and ultimately minimise such inhalation and dermal exposure risks. Containment of dusts at source is the first line of defence but the performance of such technologies needs to be verified, for which purpose the good practice guide: assessing the particulate containment performance of pharmaceutical equipment, produced by the International Society for Pharmaceutical Engineering (ISPE), is a widely used reference document. This guide recommends the use of surrogate powders that can be used to challenge the performance of such containment systems. Materials such as lactose and mannitol are recommended as their physical properties (adhesion, compactability, dustiness, flow characteristics and particle sizes) mimic those of API-containing materials typically handled. Furthermore they are safe materials to use, are available in high purity and can be procured at a reasonable cost. The aim of this work was to develop and validate a sensitive ion-chromatography based analytical procedure for the determination of surrogate powders collected on filter samples so as to meet analytical requirements set out in this ISPE guide. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  2. Sensitive determination of bismuth by flame atomic absorption spectrometry using atom trapping in a slotted quartz tube and revolatilization with organic solvent pulse

    Energy Technology Data Exchange (ETDEWEB)

    K Latin-Small-Letter-Dotless-I l Latin-Small-Letter-Dotless-I nc, Ersin, E-mail: ekilinc@dicle.edu.tr [Dicle University, Faculty of Science, Department of Chemistry, Laboratory of Chemical Analysis, TR 21280 Diyarbak Latin-Small-Letter-Dotless-I r (Turkey); Bak Latin-Small-Letter-Dotless-I rdere, Sezgin [Y Latin-Small-Letter-Dotless-I ld Latin-Small-Letter-Dotless-I z Technical University, Faculty of Education, Department of Science Education, TR 34210 Esenler-Istanbul (Turkey); Ayd Latin-Small-Letter-Dotless-I n, F Latin-Small-Letter-Dotless-I rat [Dicle University, Faculty of Science, Department of Chemistry, Laboratory of Chemical Analysis, TR 21280 Diyarbak Latin-Small-Letter-Dotless-I r (Turkey); Ataman, O. Yavuz [Middle East Technical University, Faculty of Arts and Sciences, Department of Chemistry, 06800 Ankara (Turkey)

    2012-07-15

    Sensitivity of flame atomic absorption spectrometry (FAAS) for Bi determination was improved by slotted quartz tube (SQT) that was used also for atom trapping (AT). The trapped analyte was released by aspirating a small volume of organic solvent after a reasonable analyte collection time. Sensitivity was improved by 2.9 times by SQT-FAAS and 256 times by SQT-AT-FAAS with respect to FAAS. Optimum trapping period was found to be 6.0 min (36.0 mL of solution). Limit of detection (LOD) for SQT-AT-FAAS was found to be 1.6 ng mL{sup -1}. %RSD was calculated as 4.0% for five replicate measurements of 7.5 ng mL{sup -1} Bi by SQT-AT-FAAS. Accuracy of the method developed was checked by analyzing a standard reference material of simulated fresh water (NIST 1643e) and result found was in good agreement with the certified one. The method can be applied in any laboratory equipped with a flame AA spectrometer. The consumption of time and sample volume is fairly low and application is simple and easy.

  3. Application of different methodologies in the preparation of organic matrices for determination of trace elements by differential pulse anodic stripping voltammetry; Aplicacao de diferentes metodologias na preparacao de matrizes organicas para a determinacao voltametrica de elementos traco

    Energy Technology Data Exchange (ETDEWEB)

    Sisti, Cristina

    2001-07-01

    The determination of trace elements in food samples is of great importance for the human health, considering the factors of essentiality and toxicity. On the other hand, the chemical analysis is largely affected for the steps of sample preparation; laboratory contamination of the sample and the reagents or still volatilization and losses of the elements. If these parameters are not controlled the achieved precision and accuracy could be low. In this work, the content of zinc, cadmium, lead and copper was determined in adults diet samples collected by duplicate portion technique and bovine liver, applying the differential pulse anodic stripping voltametry - (DP-ASV) technique. In the digestion of the matrices in acid medium, conventional methodologies were used, conductive heating in open recipients and equipment with microwaves source in open and closed vessels. The best procedure was the sample digestion by microwaves, in closed vessels and the other treatments made in controlled atmosphere with hood laminar-airflow class 100. The established methodology was validated with the use of a certified sample as reference (NIST - bovine liver 1577b). (author)

  4. Comparison between some determination methods of residual styrene in plastic scintillators

    International Nuclear Information System (INIS)

    Bezuglyi, V.D.; Ponomarev, Yu.P.; Gunder, O.A.; Biteman, V.B.; Senchishin, V.G.

    1988-01-01

    Scintillators made of plastic materials based on polystyrene with addition of p-terphenyl and 1,4-di-[(2,5-phenyl)oxazolyl] benzene have found wide application principally in the detection of radioactivity. The stability of the scintillating characteristics of these materials depends to great degree on the concentration of the residual monomer and for this reason it is important to have a sufficiently convenient method for the determination of this latter. We investigated the bromometric and acid-base titration methods with visual and potentiometric titration end point detection. We also examined the polarographic methods, direct and indirect, using the electroreduction of the mercury acetate complex of the monomer. We checked the methods on a scintillator sample and on synthetic mixtures, i.e., mixtures of monomer, polymer, and p-terphenyl. We compared the determination results for styrene and showed that the most accurate procedure is the bromometric determination with potentiometric indication of the end-point

  5. Modeling of Trichel pulses in negative corona

    International Nuclear Information System (INIS)

    Napartovich, A.P.; Akishev, Yu. S.; Deryugin, A.A.; Kochetov, I.V.; Pan'kin, M.V.; Trushkin, N.I.

    1998-01-01

    Results are reported of detailed numerical studies of Trichel pulse formation for dry air in short-gap coronas. Continuity equations for electrons, positive and negative ions, and the Poisson equation averaged over the current cross section were solved numerically with appropriate boundary conditions. The results of numerical simulation make it possible to analyze in detail the trailing edge of the Trichel pulse and the inter-pulse pause determining the period between pulses. In particular, the variations of the total number of negative ions in the corona spacing occurring under typical conditions of a pulsating corona, proved to be quite insignificant. A comparison with experiments demonstrated a reasonable agreement both for the shape of the pulse and for the average characteristics of the negative corona. (J.U.)

  6. SBS pulse compression for excimer inertial fusion energy drivers

    Energy Technology Data Exchange (ETDEWEB)

    Linford, G.J. [TRW Space and Electronics Group, Redondo Beach, CA (United States). Space and Technology Div.

    1994-12-31

    A key requirement for the development of commercial fusion power plants utilizing inertial confinement fusion (ICF) as a source of thermonuclear power is the availability of reliable, efficient laser drivers. These laser drivers must be capable of delivering UV optical pulses having energies of the order of 5MJ to cryogenic deuterium-tritium (D/T) ICF targets. The current requirements for laser ICF target irradiation specify the laser wavelength, {lambda} ca. 250 nm, pulse duration, {tau}{sub p} ca. 6 ns, bandwidth, {Delta}{lambda} ca. 0.1 nm, polarization state, etc. Excimer lasers are a leading candidate to fill these demanding ICF driver requirements. However, since excimer lasers are not storage lasers, the excimer laser pulse duration, {tau}{sub pp}, is determined primarily by the length of the excitation pulse delivered to the excimer laser amplifier. Pulsed power associated with efficiently generating excimer laser pulses has a time constant, {tau}{sub pp} which falls in the range, 30 {tau}{sub p}<{tau}{sub pp}<100{tau}{sub p}. As a consequence, pulse compression is needed to convert the long excimer laser pulses to pulses of duration {tau}{sub p}. These main ICF driver pulses require, in addition, longer, lower power precursor pulses delivered to the ICF target before the arrival of the main pulse. Although both linear and non-linear optical (NLO) pulse compression techniques have been developed, computer simulations have shown that a ``chirped,`` self-seeded, stimulated Brillouin scattering (SBS) pulse compressor cell using SF{sub 6} at a density, {rho} ca. 1 amagat can efficiently compress krypton fluoride (KrF) laser pulses at {lambda}=248 nm. In order to avoid the generation of output pulses substantially shorter than {tau}{sub p}, the optical power in the chirped input SBS ``seed`` beams was ramped. Compressed pulse conversion efficiencies of up to 68% were calculated for output pulse durations of {tau}{sub p} ca. ns.

  7. SBS pulse compression for excimer inertial fusion energy drivers

    International Nuclear Information System (INIS)

    Linford, G.J.

    1994-01-01

    A key requirement for the development of commercial fusion power plants utilizing inertial confinement fusion (ICF) as a source of thermonuclear power is the availability of reliable, efficient laser drivers. These laser drivers must be capable of delivering UV optical pulses having energies of the order of 5MJ to cryogenic deuterium-tritium (D/T) ICF targets. The current requirements for laser ICF target irradiation specify the laser wavelength, λ ca. 250 nm, pulse duration, τ p ca. 6 ns, bandwidth, Δλ ca. 0.1 nm, polarization state, etc. Excimer lasers are a leading candidate to fill these demanding ICF driver requirements. However, since excimer lasers are not storage lasers, the excimer laser pulse duration, τ pp , is determined primarily by the length of the excitation pulse delivered to the excimer laser amplifier. Pulsed power associated with efficiently generating excimer laser pulses has a time constant, τ pp which falls in the range, 30 τ p pp p . As a consequence, pulse compression is needed to convert the long excimer laser pulses to pulses of duration τ p . These main ICF driver pulses require, in addition, longer, lower power precursor pulses delivered to the ICF target before the arrival of the main pulse. Although both linear and non-linear optical (NLO) pulse compression techniques have been developed, computer simulations have shown that a ''chirped,'' self-seeded, stimulated Brillouin scattering (SBS) pulse compressor cell using SF 6 at a density, ρ ca. 1 amagat can efficiently compress krypton fluoride (KrF) laser pulses at λ=248 nm. In order to avoid the generation of output pulses substantially shorter than τ p , the optical power in the chirped input SBS ''seed'' beams was ramped. Compressed pulse conversion efficiencies of up to 68% were calculated for output pulse durations of τ p ca. ns

  8. Ultrashort Laser Pulse Phenomena

    CERN Document Server

    Diels, Jean-Claude

    2006-01-01

    Ultrashort Laser Pulse Phenomena, 2e serves as an introduction to the phenomena of ultra short laser pulses and describes how this technology can be used to examine problems in areas such as electromagnetism, optics, and quantum mechanics. Ultrashort Laser Pulse Phenomena combines theoretical backgrounds and experimental techniques and will serve as a manual on designing and constructing femtosecond (""faster than electronics"") systems or experiments from scratch. Beyond the simple optical system, the various sources of ultrashort pulses are presented, again with emphasis on the basic

  9. The determination by irradiation with a pulsed neutron generator and delayed neutron counting of the amount of fissile material present in a sample; Determination de la quantite de matiere fissile presente dans un echantillon par irradiation au moyen d'une source pulsee de neutrons et comptage des neutrons retardes

    Energy Technology Data Exchange (ETDEWEB)

    Beliard, L; Janot, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    A preliminary study was conducted to determine the amount of fissile material present in a sample. The method used consisted in irradiating the sample by means of a pulsed neutron generator and delayed neutron counting. Results show the validity of this method provided some experimental precautions are taken. Checking on the residual proportion of fissile material in leached hulls seems possible. (authors) [French] Ce rapport rend compte d'une etude preliminaire effectuee en vue de determiner la quantite de matiere fissile presente dans un echantillon. La methode utilisee consiste a irradier l'echantillon considere au moyen d'une source puisee de neutrons et a compter les neutrons retardes produits. Les resultats obtenus permettent de conclure a la validite de la methode moyennant certaines precautions. Un controle de la teneur residuelle en matiere fissile des gaines apres traitement semble possible. (auteurs)

  10. The characterisation of polymers using pulsed NMR

    International Nuclear Information System (INIS)

    Charlesby, A.

    1983-01-01

    Broad line pulsed NMR is applied to obtain information on radiation-induced polymer changes and other aspects of polymer science based on the interpretation of spin-spin relaxation curves. Calculations are made to determine the molecular weight, the crosslink density of simple, low molecular weight, flexible polymers. For higher molecular weight polymers, a conclusion can be drawn on the concentrations of entangled and crosslinked units by means of pulsed NMR. Some typical applications of the technique are illustrated by the examples of polyethylenes, rubbers, filled polymeric systems and aqueous polyethylene oxide solutions. The morphology of polymers can be followed by pulsed NMR. (V.N.)

  11. Pulse amplitude and frequency effects in a pulsed packed column

    International Nuclear Information System (INIS)

    Russell, S.H.

    1954-04-01

    A study has been made of the effect on the efficiency and capacity of applying pulses of varying amplitude and frequency to a packed column. In the efficiency studies, the maximum efficiency was obtained with a pulse having an amplitude of 3/8'' and a frequency of 140 cycles per minute. Under these conditions, the column was about five times as efficient as a simple packed column. Two general types of results were obtained in the capacity studies. Under certain conditions, the capacity increased over that of a simple packed column, but under others, it decreased. Some of the factors causing this were investigated but the fundamental reasons were not determined due to a lack of personnel for the necessary experiments. (author)

  12. Pulse amplitude and frequency effects in a pulsed packed column

    Energy Technology Data Exchange (ETDEWEB)

    Russell, S H

    1954-04-15

    A study has been made of the effect on the efficiency and capacity of applying pulses of varying amplitude and frequency to a packed column. In the efficiency studies, the maximum efficiency was obtained with a pulse having an amplitude of 3/8'' and a frequency of 140 cycles per minute. Under these conditions, the column was about five times as efficient as a simple packed column. Two general types of results were obtained in the capacity studies. Under certain conditions, the capacity increased over that of a simple packed column, but under others, it decreased. Some of the factors causing this were investigated but the fundamental reasons were not determined due to a lack of personnel for the necessary experiments. (author)

  13. Gas phase pulse radiolysis

    International Nuclear Information System (INIS)

    Jonah, C.D.; Andong Liu; Mulac, W.A.

    1987-01-01

    Gas phase pulse radiolysis, a technique which can be used to study many different phenomena in chemistry and physics, is discussed. As a source of small radicals, pulse radiolysis is important to the field of chemistry, particularly to combustion and atmospheric kinetics. The reactions of 1,3-butadiene, allene, ethylene and acetylene with OH are presented. 52 refs., 1 fig., 1 tab

  14. Pulse duration discriminator

    International Nuclear Information System (INIS)

    Kosakovskij, L.F.

    1980-01-01

    Basic circuits of a discriminator for discrimination of pulses with the duration greater than the preset one, and of a multifunctional discriminator allowing to discriminate pulses with the duration greater (tsub(p)>tsub(s)) and lesser (tsub(p) tsub(s) and with the duration tsub(p) [ru

  15. Sources of pulsed radiation

    International Nuclear Information System (INIS)

    Sauer, M.C. Jr.

    1981-01-01

    Characteristics of various sources of pulsed radiation are examined from the viewpoint of their importance to the radiation chemist, and some examples of uses of such sources are mentioned. A summary is given of the application of methods of physical dosimetry to pulsed sources, and the calibration of convenient chemical dosimeters by physical dosimetry is outlined. 7 figures, 1 table

  16. Pulsed neutron generator

    International Nuclear Information System (INIS)

    Bespalov, D.F.; Bykovskii, Yu.A.; Vergun, I.I.; Kozlovskii, K.I.; Kozyrev, Yu.P.; Leonov, R.K.; Simagin, B.I.; Tsybin, A.S.; Shikanov, A.Ie.

    1986-03-01

    The paper describes a new device for generating pulsed neutron fields, utilized in nuclear geophysics for carrying out pulsed neutron logging and activation analysis under field conditions. The invention employs a sealed-off neutron tube with a laser ion source which increases neutron yield to the level of 10 neutrons per second or higher. 2 refs., 1 fig

  17. Bipolar pulse generator for intense pulsed ion beam accelerator

    International Nuclear Information System (INIS)

    Ito, H.; Igawa, K.; Kitamura, I.; Masugata, K.

    2007-01-01

    A new type of pulsed ion beam accelerator named ''bipolar pulse accelerator'' (BPA) has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator for the bipolar pulse experiment, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the first experimental result of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PFL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time

  18. Pulse induction heating

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A S; Kachanov, B Y; Kogan, B V

    1993-12-31

    Induction heating and three types of pulse processes were studied. It was found that in pulse processes the frequency and pulse duration of heat treatments do not remain constant. High frequency pulse heat treatments can be used on sprayed coatings; such treatments will result in stronger surfaces with no cracks. For induction hardening, the rate of specific power was 1 to 1.5 kW/sq.cm, for forging it was 0.2 to 0.3 kW/sq.cm and for melting it was 0.05 to 0.1 kW/sq.cm. The application of pulse heating will result in higher rates of specific power.

  19. Pulse Distortion in Saturated Fiber Optical Parametric Chirped Pulse Amplification

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Da Ros, Francesco; Rottwitt, Karsten

    2012-01-01

    Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation.......Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation....

  20. Voltammetric Behaviour and Analysis of Fluchloralin

    OpenAIRE

    K. Balaji; C. Sridevi; N. Ananda Kumar Reddy; K. Mohana Muni Sidda Reddy; C. Suresh Reddy

    2010-01-01

    The electrochemical reduction behavior of fluchloralin has been studied by D.C.polarography, differential pulse polarography, millicoulometry and controlled potential electrolysis in the universal buffers ranging from 2.0 to 12.0. Kinetic parameters were evaluated and a reduction mechanism was proposed. A simple and rapid differential pulse polarographic method has been developed for the determination of fluchloralin in formulations, grains, soils and spiked water samples. The lower detection...

  1. Pulse Propagation on close conductors

    CERN Document Server

    Dieckmann, A

    2001-01-01

    The propagation and reflection of arbitrarily shaped pulses on non-dispersive parallel conductors of finite length with user defined cross section is simulated employing the discretized telegraph equation. The geometry of the system of conductors and the presence of dielectric material determine the capacities and inductances that enter the calculation. The values of these parameters are found using an iterative Laplace equation solving procedure and confirmed for certain calculable geometries including the line charge inside a box. The evolving pulses and the resulting crosstalk can be plotted at any instant and - in the Mathematica notebook version of this report - be looked at in an animation. As an example a differential pair of microstrips as used in the ATLAS vertex detector is analysed.

  2. Pulse Width Affects Scalp Sensation of Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Peterchev, Angel V; Luber, Bruce; Westin, Gregory G; Lisanby, Sarah H

    Scalp sensation and pain comprise the most common side effect of transcranial magnetic stimulation (TMS), which can reduce tolerability and complicate experimental blinding. We explored whether changing the width of single TMS pulses affects the quality and tolerability of the resultant somatic sensation. Using a controllable pulse parameter TMS device with a figure-8 coil, single monophasic magnetic pulses inducing electric field with initial phase width of 30, 60, and 120 µs were delivered in 23 healthy volunteers. Resting motor threshold of the right first dorsal interosseus was determined for each pulse width, as reported previously. Subsequently, pulses were delivered over the left dorsolateral prefrontal cortex at each of the three pulse widths at two amplitudes (100% and 120% of the pulse-width-specific motor threshold), with 20 repetitions per condition delivered in random order. After each pulse, subjects rated 0-to-10 visual analog scales for Discomfort, Sharpness, and Strength of the sensation. Briefer TMS pulses with amplitude normalized to the motor threshold were perceived as slightly more uncomfortable than longer pulses (with an average 0.89 point increase on the Discomfort scale for pulse width of 30 µs compared to 120 µs). The sensation of the briefer pulses was felt to be substantially sharper (2.95 points increase for 30 µs compared to 120 µs pulse width), but not stronger than longer pulses. As expected, higher amplitude pulses increased the perceived discomfort and strength, and, to a lesser degree the perceived sharpness. Our findings contradict a previously published hypothesis that briefer TMS pulses are more tolerable. We discovered that the opposite is true, which merits further study as a means of enhancing tolerability in the context of repetitive TMS. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Optical pulse compression

    International Nuclear Information System (INIS)

    Glass, A.J.

    1975-01-01

    The interest in using large lasers to achieve a very short and intense pulse for generating fusion plasma has provided a strong impetus to reexamine the possibilities of optical pulse compression at high energy. Pulse compression allows one to generate pulses of long duration (minimizing damage problems) and subsequently compress optical pulses to achieve the short pulse duration required for specific applications. The ideal device for carrying out this program has not been developed. Of the two approaches considered, the Gires--Tournois approach is limited by the fact that the bandwidth and compression are intimately related, so that the group delay dispersion times the square of the bandwidth is about unity for all simple Gires--Tournois interferometers. The Treacy grating pair does not suffer from this limitation, but is inefficient because diffraction generally occurs in several orders and is limited by the problem of optical damage to the grating surfaces themselves. Nonlinear and parametric processes were explored. Some pulse compression was achieved by these techniques; however, they are generally difficult to control and are not very efficient. (U.S.)

  4. RF Pulsed Heating

    Energy Technology Data Exchange (ETDEWEB)

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  5. Dynamic pulse difference circuit

    International Nuclear Information System (INIS)

    Erickson, G.L.

    1978-01-01

    A digital electronic circuit of especial use for subtracting background activity pulses in gamma spectrometry is disclosed which comprises an up-down counter connected to count up with signal-channel pulses and to count down with background-channel pulses. A detector responsive to the count position of the up-down counter provides a signal when the up-down counter has completed one scaling sequence cycle of counts in the up direction. In an alternate embodiment, a detector responsive to the count position of the up-down counter provides a signal upon overflow of the counter

  6. Coaxial pulse matching transformer

    International Nuclear Information System (INIS)

    Ledenev, V.V.; Khimenko, L.T.

    1986-01-01

    This paper describes a coaxial pulse matching transformer with comparatively simple design, increased mechanical strength, and low stray inductance. The transformer design makes it easy to change the turns ratio. The circuit of the device and an expression for the current multiplication factor are presented; experiments confirm the efficiency of the transformer. Apparatus with a coaxial transformer for producing high-power pulsed magnetic fields is designed (current pulses of 1-10 MA into a load and a natural frequency of 100 kHz)

  7. Pulse-width discriminators

    International Nuclear Information System (INIS)

    Budyashov, Yu.G.; Grebenyuk, V.M.; Zinov, V.G.

    1978-01-01

    A pulse duration discriminator is described which is intended for processing signals from multilayer scintillators. The basic elements of the scintillator are: an input gate, a current generator, an integrating capacitor, a Schmidt trigger and an anticoincidence circuit. The basic circuit of the discriminator and its time diagrams explaining its operating are given. The discriminator is based on microcircuits. Pulse duration discrimination threshold changes continuously from 20 to 100 ns, while its amplitude threshold changes within 20 to 100 mV. The temperature instability of discrimination thresholds (both in pulse width and in amplitude) is better than 0.1 per cent/deg C

  8. Multimode pulse counter

    International Nuclear Information System (INIS)

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  9. Pulsed atomic soliton laser

    International Nuclear Information System (INIS)

    Carr, L.D.; Brand, J.

    2004-01-01

    It is shown that simultaneously changing the scattering length of an elongated, harmonically trapped Bose-Einstein condensate from positive to negative and inverting the axial portion of the trap, so that it becomes expulsive, results in a train of self-coherent solitonic pulses. Each pulse is itself a nondispersive attractive Bose-Einstein condensate that rapidly self-cools. The axial trap functions as a waveguide. The solitons can be made robustly stable with the right choice of trap geometry, number of atoms, and interaction strength. Theoretical and numerical evidence suggests that such a pulsed atomic soliton laser can be made in present experiments

  10. DogPulse

    DEFF Research Database (Denmark)

    Skovgaard, Christoffer; Thomsen, Josephine Raun; Verdezoto, Nervo

    2015-01-01

    This paper presents DogPulse, an ambient awareness system to support the coordination of dog walking among family members at home. DogPulse augments a dog collar and leash set to activate an ambient shape-changing lamp and visualize the last time the dog was taken for a walk. The lamp gradually...... changes its form and pulsates its lights in order to keep the family members aware of the dog walking activity. We report the iterative prototyping of DogPulse, its implementation and its preliminary evaluation. Based on our initial findings, we present the limitations and lessons learned as well...

  11. Simultaneous extraction and determination of lead, cadmium and copper in rice samples by a new pre-concentration technique: Hollow fiber solid phase microextraction combined with differential pulse anodic stripping voltammetry

    Energy Technology Data Exchange (ETDEWEB)

    Es' haghi, Zarrin, E-mail: z_eshaghi@pnu.ac.i [Department of Chemistry, Faculty of Sciences, Payame Noor University, Mashhad (Iran, Islamic Republic of); Khalili, Maryam; Khazaeifar, Ali [Department of Chemistry, Faculty of Sciences, Payame Noor University, Mashhad (Iran, Islamic Republic of); Rounaghi, Gholam Hossein [Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad (Iran, Islamic Republic of)

    2011-03-30

    In the present work, a novel solid phase microextraction (SPME) technique using a hollow fiber-supported sol-gel combined with multi-walled carbon nanotubes, coupled with differential pulse anodic stripping voltammetry (DPASV) was employed in the simultaneous extraction and determination of lead, cadmium and copper in rice. In this technique, an innovative solid sorbent containing mixture of carbon nanotube and a composite microporous compound was developed by the sol-gel method via the reaction of tetraethylorthosilicate (TEOS) with 2-amino-2-hydroxymethyl-propane-1,3-diol (TRIS). The growth process was initiated in basic condition (pH 10-11). Afterward this sol was injected into a polypropylene hollow fiber segment for in situ gelation process. The main factors influencing the pre-concentration and extraction of the metal ions; pH of the aqueous feed solution, extraction time, aqueous feed volume, agitation speed, the role of carbon nanotube reinforcement (as-grown and functionalized MWCNT) and salting effect have been examined in detail. Under the optimized conditions, linear calibration curves were established for the concentration of Cd(II), Pb(II) and Cu(II) in the range of 0.05-500, 0.05-500 and 0.01-100 ng mL{sup -1}, respectively. Detection limits obtained in this way are, 0.01, 0.025 and 0.0073 ng mL{sup -1} for Cd(II), Pb(II) and Cu(II), respectively. The relative standard deviations (RSDs) were found to be less than 5% (n = 5, conc.: 1.0 ng mL{sup -1}).

  12. Various electroanalytical methods for the determination of uranium in different matrices

    Directory of Open Access Journals (Sweden)

    Alankar Shrivastava

    2013-06-01

    Full Text Available Uranium is a toxic material hence numerous body systems such as the kidney, brain, liver, and heart can be affected by uranium exposure. The main effect is kidney toxicity. Uranium is a naturally occurring element found in low levels in all rock, soil, and water. All uranium isotopes may also cause radiation hazards, thus without any doubt an analysis of such materials in the surrounding environment is very important. The presented review is a summarization of all electroanalytical techniques for the determination of uranium and its compounds in various matrices. Totally 43 different methods are found in our literature survey. Out of these three are polarographic, 25 potentiometry, five capillary electrophoresis and 28 voltametric methods are available in the literature. Interferences of different ions and applications in different matrices are also given for each method.

  13. Thermal models of pulse electrochemical machining

    International Nuclear Information System (INIS)

    Kozak, J.

    2004-01-01

    Pulse electrochemical machining (PECM) provides an economical and effective method for machining high strength, heat-resistant materials into complex shapes such as turbine blades, die, molds and micro cavities. Pulse Electrochemical Machining involves the application of a voltage pulse at high current density in the anodic dissolution process. Small interelectrode gap, low electrolyte flow rate, gap state recovery during the pulse off-times lead to improved machining accuracy and surface finish when compared with ECM using continuous current. This paper presents a mathematical model for PECM and employs this model in a computer simulation of the PECM process for determination of the thermal limitation and energy consumption in PECM. The experimental results and discussion of the characteristics PECM are presented. (authors)

  14. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  15. IAE pulsed electrostatic accelerator

    International Nuclear Information System (INIS)

    Afanas'ev, V.P.; Ganzhelyuk, M.L.; Kozlov, L.D.; Koltypin, E.A.; Molchanov, Yu.D.; Otroshchenko, G.A.; Yan'kov, G.B.

    1976-01-01

    The modernized pulse electrostatic accelerator using the klystron ion grouping and the beam interruption system prior to acceleration is described. The accelerator is modernized in order to improve parameters of a current pulse and to decrease the background in the measurement room. The ion beam of needed dimensions is obtained with the help of a high-frequency source and a beam grouping and deflection system. The general view of the beam grouping and deflection system is shown. The ion beam forming process is considered in detail. The modernized electrostatic accelerator permits to obtain a pulse current with a pulse length of 1.5 ns and an amplitude of 1.5 - 2 μA. With the repetition frequency of 2 MHz, the average target current is about 6 μA

  16. International Year of Pulses 2016 | 2016 International Year of Pulses

    Science.gov (United States)

    the Year in collaboration with Governments, relevant organizations, non-governmental organizations and the composition of pulses Image 4 Wrapping up the International Year of Pulses The 5 key messages to food security Infographic Pulses and climate change International Year of Pulses 2016 The 68th UN

  17. Realtime aspects of pulse-to-pulse modulation

    International Nuclear Information System (INIS)

    Steiner, R.; Riedel, C.; Roesch, W.

    1992-01-01

    The pulse-to-pulse modulation of the SIS-ESR control system is described. Fast response to operator interaction and to changes in process conditions is emphasized as well as the essential part played by the timing system in pulse-to-pulse modulation. (author)

  18. Pulsed spallation Neutron Sources

    International Nuclear Information System (INIS)

    Carpenter, J.M.

    1994-01-01

    This paper reviews the early history of pulsed spallation neutron source development at Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provides a few examples of applications in fundamental condensed matter physics, materials science and technology

  19. Pulsed spallation neutron sources

    International Nuclear Information System (INIS)

    Carpenter, J.M.

    1996-01-01

    This paper reviews the early history of pulsed spallation neutron source development ar Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provide a few examples of applications in fundamental condensed matter physics, materials science and technology

  20. Periodic dark pulse emission induced by delayed feedback in a quantum well semiconductor laser

    Directory of Open Access Journals (Sweden)

    L. Li

    2012-12-01

    Full Text Available We report the experimental observation of periodic dark pulse emission in a quantum-well semiconductor laser with delayed optical feedback. We found that under appropriate operation conditions the laser can also emit a stable train of dark pulses. The repetition frequency of the dark pulse is determined by the external cavity length. Splitting of the dark pulse was also observed. We speculate that the observed dark pulse is a kind of temporal cavity soliton formed in the laser.

  1. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  2. Ultrashort X-ray pulse science

    International Nuclear Information System (INIS)

    Chin, A.H.; Lawrence Berkeley National Lab., CA

    1998-01-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90 o Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ∼ 300 fs, 30 keV (0.4 (angstrom)) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been

  3. Pulsed dc self-sustained magnetron sputtering

    International Nuclear Information System (INIS)

    Wiatrowski, A.; Posadowski, W. M.; Radzimski, Z. J.

    2008-01-01

    The magnetron sputtering has become one of the commonly used techniques for industrial deposition of thin films and coatings due to its simplicity and reliability. At standard magnetron sputtering conditions (argon pressure of ∼0.5 Pa) inert gas particles (necessary to sustain discharge) are often entrapped in the deposited films. Inert gas contamination can be eliminated during the self-sustained magnetron sputtering (SSS) process, where the presence of the inert gas is not a necessary requirement. Moreover the SSS process that is possible due to the high degree of ionization of the sputtered material also gives a unique condition during the transport of sputtered particles to the substrate. So far it has been shown that the self-sustained mode of magnetron operation can be obtained using dc powering (dc-SSS) only. The main disadvantage of the dc-SSS process is its instability related to random arc formation. In such case the discharge has to be temporarily extinguished to prevent damaging both the magnetron source and power supply. The authors postulate that pulsed powering could protect the SSS process against arcs, similarly to reactive pulsed magnetron deposition processes of insulating thin films. To put this concept into practice, (i) the high enough plasma density has to be achieved and (ii) the type of pulsed powering has to be chosen taking plasma dynamics into account. In this article results of pulsed dc self-sustained magnetron sputtering (pulsed dc-SSS) are presented. The planar magnetron equipped with a 50 mm diameter and 6 mm thick copper target was used during the experiments. The maximum target power was about 11 kW, which corresponded to the target power density of ∼560 W/cm 2 . The magnetron operation was investigated as a function of pulse frequency (20-100 kHz) and pulse duty factor (50%-90%). The discharge (argon) extinction pressure level was determined for these conditions. The plasma emission spectra (400-410 nm range) and deposition

  4. Particle acceleration by electromagnetic pulses

    International Nuclear Information System (INIS)

    Lai, H.M.

    1982-01-01

    Particle interaction with plane electromagnetic pulses is studied. It is shown that particle acceleration by a wavy pulse, depending on the shape of the pulse, may not be small. Further, a diffusive-type particle acceleration by multiple weak pulses is described and discussed. (author)

  5. Dynamics of traveling reaction pulses

    International Nuclear Information System (INIS)

    Dovzhenko, A. Yu.; Rumanov, E. N.

    2007-01-01

    The growth of activator losses is accompanied by the decay of a traveling reaction pulse. In a ring reactor, this propagation threshold is present simultaneously with a threshold related to the ring diameter. The results of numerical experiments with pulses of an exothermal reaction reveal the transition from pulse propagation to a homogeneous hot regime, established regimes with periodic variations of the pulse velocity, and oscillatory decay of the pulse. When the medium becomes 'bistable' as a result of the variation in parameters, this factor does not prevent the propagation of pulses, but leads to changes in the pulse structure

  6. Ultrashort laser pulses and electromagnetic pulse generation in air and on dielectric surfaces

    International Nuclear Information System (INIS)

    Sprangle, P.; Penano, J.R.; Hafizi, B.; Kapetanakos, C.A.

    2004-01-01

    Intense, ultrashort laser pulses propagating in the atmosphere have been observed to emit sub-THz electromagnetic pulses (EMPS). The purpose of this paper is to analyze EMP generation from the interaction of ultrashort laser pulses with air and with dielectric surfaces and to determine the efficiency of conversion of laser energy to EMP energy. In our self-consistent model the laser pulse partially ionizes the medium, forms a plasma filament, and through the ponderomotive forces associated with the laser pulse, drives plasma currents which are the source of the EMP. The propagating laser pulse evolves under the influence of diffraction, Kerr focusing, plasma defocusing, and energy depletion due to electron collisions and ionization. Collective effects and recombination processes are also included in the model. The duration of the EMP in air, at a fixed point, is found to be a few hundred femtoseconds, i.e., on the order of the laser pulse duration plus the electron collision time. For steady state laser pulse propagation the flux of EMP energy is nonradiative and axially directed. Radiative EMP energy is present only for nonsteady state or transient laser pulse propagation. The analysis also considers the generation of EMP on the surface of a dielectric on which an ultrashort laser pulse is incident. For typical laser parameters, the power and energy conversion efficiency from laser radiation to EMP radiation in both air and from dielectric surfaces is found to be extremely small, -8 . Results of full-scale, self-consistent, numerical simulations of atmospheric and dielectric surface EMP generation are presented. A recent experiment on atmospheric EMP generation is also simulated

  7. Steady State versus Pulsed Tokamak DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Orsitto, F.P., E-mail: francesco.orsitto@enea.it [Associazione EURATOM-ENEA Unita Tecnica Fusione, Frascati (Italy); Todd, T. [CCFE/Fusion Association, Culham Science Centre, Abingdon (United Kingdom)

    2012-09-15

    Full text: The present report deals with a Review of problems for a Steady state(SS) DEMO, related argument is treated about the models and the present status of comparison between the characteristics of DEMO pulsed versus a Steady state device.The studied SS DEMO Models (SLIM CS, PPCS model C EU-DEMO, ARIES-RS) are analyzed from the point of view of the similarity scaling laws and critical issues for a steady state DEMO. A comparison between steady state and pulsed DEMO is therefore carried out: in this context a new set of parameters for a pulsed (6 - 8 hours pulse) DEMO is determined working below the density limit, peak temperature of 20 keV, and requiring a modest improvement in the confinement factor(H{sub IPBy2} = 1.1) with respect to the H-mode. Both parameters density and confinement parameter are lower than the DEMO models presently considered. The concept of partially non-inductive pulsed DEMO is introduced since a pulsed DEMO needs heating and current drive tools for plasma stability and burn control. The change of the main parameter design for a DEMO working at high plasma peak temperatures T{sub e} {approx} 35 keV is analyzed: in this range the reactivity increases linearly with temperature, and a device with smaller major radius (R = 7.5 m) is compatible with high temperature. Increasing temperature is beneficial for current drive efficiency and heat load on divertor, being the synchrotron radiation one of the relevant components of the plasma emission at high temperatures and current drive efficiency increases with temperature. Technology and engineering problems are examined including efficiency and availability R&D issues for a high temperature DEMO. Fatigue and creep-fatigue effects of pulsed operations on pulsed DEMO components are considered in outline to define the R&D needed for DEMO development. (author)

  8. Pulsed-DC selfsputtering of copper

    International Nuclear Information System (INIS)

    Wiatrowski, A; Posadowski, W M; Radzimski, Z J

    2008-01-01

    At standard magnetron sputtering conditions (argon pressure ∼0.5 Pa) inert gas particles are often entrapped in the formed films. Inert gas contamination can be eliminated by using the self-sustained magnetron sputtering process because it is done in the absence of the inert gas atmosphere. The self-sustained sputtering (SSS) gives also a unique condition during the transport of sputtered particles to the substrate. It is especially useful for filling high aspect ratio submicron scale structures for microelectronics. So far it has been shown that the self-sputtering process can be sustained in the DC operation mode (DC-SSS) only. The main disadvantage of DC-SSS process is instability related to possible arc formation. Usage of pulsed sputtering, similarly to reactive pulsed magnetron sputtering, could eliminate this problem. In this paper results of pulsed-DC self-sustained magnetron sputtering (pulsed DC-SSS) of copper are presented for the first time. The planar magnetron equipped with a 50 mm in diameter and 6 mm thick copper target was powered by DC-power supply modulated by power switch. The maximum target power was about 11 kW (∼550W/cm 2 ). The magnetron operation was investigated as a function of pulsing frequency (20-100 kHz) and duty factor (50-90%). The discharge extinction pressure was determined for these conditions. The plasma emission spectra (400-410nm range) and deposition rates were observed for both DC and pulsed DC sustained self-sputtering processes. The presented results illustrate that stable pulsed DC-SSS process can be obtained at pulsing frequency in the range of 60-100 kHz and duty factor of 70-90%

  9. Pulsed-DC selfsputtering of copper

    Science.gov (United States)

    Wiatrowski, A.; Posadowski, W. M.; Radzimski, Z. J.

    2008-03-01

    At standard magnetron sputtering conditions (argon pressure ~0.5 Pa) inert gas particles are often entrapped in the formed films. Inert gas contamination can be eliminated by using the self-sustained magnetron sputtering process because it is done in the absence of the inert gas atmosphere. The self-sustained sputtering (SSS) gives also a unique condition during the transport of sputtered particles to the substrate. It is especially useful for filling high aspect ratio submicron scale structures for microelectronics. So far it has been shown that the self-sputtering process can be sustained in the DC operation mode (DC-SSS) only. The main disadvantage of DC-SSS process is instability related to possible arc formation. Usage of pulsed sputtering, similarly to reactive pulsed magnetron sputtering, could eliminate this problem. In this paper results of pulsed-DC self-sustained magnetron sputtering (pulsed DC-SSS) of copper are presented for the first time. The planar magnetron equipped with a 50 mm in diameter and 6 mm thick copper target was powered by DC-power supply modulated by power switch. The maximum target power was about 11 kW (~550W/cm2). The magnetron operation was investigated as a function of pulsing frequency (20-100 kHz) and duty factor (50-90%). The discharge extinction pressure was determined for these conditions. The plasma emission spectra (400-410nm range) and deposition rates were observed for both DC and pulsed DC sustained self-sputtering processes. The presented results illustrate that stable pulsed DC-SSS process can be obtained at pulsing frequency in the range of 60-100 kHz and duty factor of 70-90%.

  10. Effectiveness of Pulse Oximetry Versus Doppler for Tourniquet Monitoring.

    Science.gov (United States)

    Wall, Piper L; Buising, Charisse M; Grulke, Lisa; Troester, Alexander; Bianchina, Nicholas; White, Shannon; Freymark, Rosemarie; Hassan, Ali; Hopkins, James W; Renner, Catherine Hackett; Sahr, Sheryl M

    Pulse oximeters are common and include arterial pulse detection as part of their methodology. The authors investigated the possible usefulness of pulse oximeters for monitoring extremity tourniquet arterial occlusion. Tactical Ratcheting Medical Tourniquets were tightened to the least Doppler-determined occluding pressure at mid-thigh or mid-arm locations on one limb at a time on all four limbs of 15 volunteers. A randomized block design was used to determine the placement locations of three pulse oximeter sensors on the relevant digits. The times and pressures of pulsatile signal absences and returns were recorded for 200 seconds, with the tourniquet being tightened only when the Doppler ultrasound and all three pulse oximeters had pulsatile signals present (pulsatile waveform traces for the pulse oximeters). From the first Doppler signal absence to tourniquet release, toe-located pulse oximeters missed Doppler signal presence 41% to 50% of the times (discrete 1-second intervals) and missed 39% to 49% of the pressure points (discrete 1mmHg intervals); fingerlocated pulse oximeters had miss rates of 11% to 15% of the times and 13% to 19% of the pressure points. On toes, the pulse oximeter ranges of sensitivity and specificity for Doppler pulse detection were 71% to 90% and 44% to 51%, and on fingers, the respective ranges were 65% to 77% and 78% to 83%. Use of a pulse oximeter to monitor limb tourniquet effectiveness will result in some instances of an undetected weak arterial pulse being present. If a pulse oximeter waveform is obtained from a location distal to a tourniquet, the tourniquet should be tightened. If a pulsatile waveform is not detected, vigilance should be maintained. 2017.

  11. Pulsed rf excited spectrometer having improved pulse width control

    International Nuclear Information System (INIS)

    1977-01-01

    RF excitation for a spectrometer is obtained by pulse width modulating an RF carrier to produce the desired broadband RF exciting spectrum. The RF excitation includes a train of composite RF pulses, each composite pulse having a primary pulse portion of a first RF phase and a second pulse portion of a second RF phase opposite that of the first. In this manner, the finite rise and fall times of the primary pulse portion are compensated for by the corresponding rise and fall times of the secondary pulse portion. The primary pulse portion is lengthened by an amount equal to the secondary pulse portion so that the secondary pulse portion cancels the added primary pulse portion. In a spectrometer, the compensating second pulse component removes certain undesired side bands of the RF excitation caused by the finite rise and fall times of the applied RF pulses. The compensating second pulse component removes certain undesired side bands associated with each of the resonant lines of the excited resonance spectrum of the sample under analysis, particularly for wide band RF excitation

  12. Space Vector Pulse Width Modulation of a Multi-Level Diode ...

    African Journals Online (AJOL)

    Space Vector Pulse Width Modulation of a Multi-Level Diode Clamped ... of MATLAB /SIMULINK modeling of the space vector pulse-width modulation and the ... two adjacent active vectors in determining the switching process of the multilevel ...

  13. Herophilus on pulse

    Directory of Open Access Journals (Sweden)

    Afonasin, Eugene

    2015-01-01

    Full Text Available The first detailed study of the pulse (sphygmology is associated in antiquity with Herophilus (the end of the 4th century BCE, an Alexandrian physician, renowned for his anatomical discoveries. The scholars also attribute to him a discovery of a portable and adjustable water-clock, used for measuring ‘natural’ and ‘unnatural’ pulse and, accordingly, temperature of the patient. In the article we translate the principal ancient evidences and comment upon them. We study both the practical aspects of ancient sphygmology and the theoretical speculations associated with it. Ancient theory of proportion and musical harmony allowed to build a classification of the pulses, but the medical experience did not fit well in the Procrustean bed of this rather simple theory.

  14. Current Extensions on PULSE

    Directory of Open Access Journals (Sweden)

    Sanda Dragos

    2010-09-01

    Full Text Available Using a learning management system (LMS is a common practise nowadays. Such instruments are used in educational institutions to enhance and support the teaching act as well as in industry for training purposes. In a computer science department of an university such instrument tends to be a basic requirement. That is because not only it allows a better management of courses and a better communication between students and professors, but can also serve as a perfect instrument for presenting teaching related materials for computer science subjects. During the years I have created and used several such instruments: a System with Interactive ackNowledgement and Evaluation of students work during laboratory sessions (SINE, a Php Utility used in Laboratories for Student Evaluation (PULSE, and PULSE Extended. The aim of this paper is to present the current enhancements of PULSE.

  15. Millimicrosecond pulse techniques

    CERN Document Server

    Lewis, Ian A D

    1959-01-01

    Millimicrosecond Pulse Techniques, Second Edition focuses on millimicrosecond pulse techniques and the development of devices of large bandwidth, extending down to comparatively low frequencies (1 Mc/s). Emphasis is on basic circuit elements and pieces of equipment of universal application. Specific applications, mostly in the field of nuclear physics instrumentation, are considered. This book consists of eight chapters and opens with an introduction to some of the terminology employed by circuit engineers as well as theoretical concepts, including the laws of circuit analysis, Fourier analysi

  16. Pulsed Plasma Electron Sources

    Science.gov (United States)

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Saveliev, J. Appl. Phys. 98, 093308 (2005). Ya. E. Krasik, A. Dunaevsky, and J. Felsteiner, Phys. Plasmas 8, 2466 (2001). D. Yarmolich, V. Vekselman, V. Tz. Gurovich, and Ya. E. Krasik, Phys. Rev. Lett. 100, 075004 (2008). J. Z. Gleizer, Y. Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  17. Spallation neutrons pulsed sources

    International Nuclear Information System (INIS)

    Carpenter, J.

    1996-01-01

    This article describes the range of scientific applications which can use these pulsed neutrons sources: Studies on super fluids, measures to verify the crawling model for the polymers diffusion; these sources are also useful to study the neutron disintegration, the ultra cold neutrons. In certain applications which were not accessible by neutrons diffusion, for example, radiations damages, radionuclides production and activation analysis, the spallation sources find their use and their improvement will bring new possibilities. Among others contributions, one must notice the place at disposal of pulsed muons sources and neutrinos sources. (N.C.). 3 figs

  18. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  19. Pulse Synchronization System (PSS)

    International Nuclear Information System (INIS)

    1977-06-01

    This document is intended to serve as an operations manual, as well as a documentation of the backup analyses pertinent to the design as delivered. A history of earlier unsuccessful versions of the Pulse Synchronization System (PSS) is not included. The function of the PSS is to synchronize the time of arrival at the fusion target of laser pulses that are propagated through the 20 amplifier chains of the SHIVA laser. The positional accuracy requirement is +-1.5 mm (+-5 psec), and is obtained by the PSS with a wide margin factor

  20. Physical model of reactor pulse

    International Nuclear Information System (INIS)

    Petrovic, A.; Ravnik, M.

    2004-01-01

    Pulse experiments have been performed at J. Stefan Institute TRIGA reactor since 1991. In total, more than 130 pulses have been performed. Extensive experimental information on the pulse physical characteristics has been accumulated. Fuchs-Hansen adiabatic model has been used for predicting and analysing the pulse parameters. The model is based on point kinetics equation, neglecting the delayed neutrons and assuming constant inserted reactivity in form of step function. Deficiencies of the Fuchs-Hansen model and systematic experimental errors have been observed and analysed. Recently, the pulse model was improved by including the delayed neutrons and time dependence of inserted reactivity. The results explain the observed non-linearity of the pulse energy for high pulses due to finite time of pulse rod withdrawal and the contribution of the delayed neutrons after the prompt part of the pulse. The results of the improved model are in good agreement with experimental results. (author)

  1. Reconstruction of Attosecond Pulse Trains Using an Adiabatic Phase Expansion

    International Nuclear Information System (INIS)

    Varju, K.; Gustafsson, E.; Johnsson, P.; Mauritsson, J.; L'Huillier, A.; Mairesse, Y.; Agostini, P.; Breger, P.; Carre, B.; Merdji, H.; Monchicourt, P.; Salieres, P.; Frasinski, L.J.

    2005-01-01

    We propose a new method to reconstruct the electric field of attosecond pulse trains. The phase of the high-order harmonic emission electric field is Taylor expanded around the maximum of the laser pulse envelope in the time domain and around the central harmonic in the frequency domain. Experimental measurements allow us to determine the coefficients of this expansion and to characterize the radiation with attosecond accuracy over a femtosecond time scale. The method gives access to pulse-to-pulse variations along the train, including the timing, the chirp, and the attosecond carrier envelope phase

  2. Probabilistic SSME blades structural response under random pulse loading

    Science.gov (United States)

    Shiao, Michael; Rubinstein, Robert; Nagpal, Vinod K.

    1987-01-01

    The purpose is to develop models of random impacts on a Space Shuttle Main Engine (SSME) turbopump blade and to predict the probabilistic structural response of the blade to these impacts. The random loading is caused by the impact of debris. The probabilistic structural response is characterized by distribution functions for stress and displacements as functions of the loading parameters which determine the random pulse model. These parameters include pulse arrival, amplitude, and location. The analysis can be extended to predict level crossing rates. This requires knowledge of the joint distribution of the response and its derivative. The model of random impacts chosen allows the pulse arrivals, pulse amplitudes, and pulse locations to be random. Specifically, the pulse arrivals are assumed to be governed by a Poisson process, which is characterized by a mean arrival rate. The pulse intensity is modelled as a normally distributed random variable with a zero mean chosen independently at each arrival. The standard deviation of the distribution is a measure of pulse intensity. Several different models were used for the pulse locations. For example, three points near the blade tip were chosen at which pulses were allowed to arrive with equal probability. Again, the locations were chosen independently at each arrival. The structural response was analyzed both by direct Monte Carlo simulation and by a semi-analytical method.

  3. Measurement of subcriticality by a pulsing α-method

    International Nuclear Information System (INIS)

    Jitarev, V.E.; Kachanov, V.M.; Kuzmin, A.N.

    1999-01-01

    The report presents results of a pulsing α-method [1] for determination of the WWER system subcriticality. The pulsing α-method permits to conduct measurements of system subcriticality in conditions of subcritical state and large neutron background. Therefore this method can be used for the control of a subcriticality of storehouses of a burn up nuclear fuel and stopped reactor. (Authors)

  4. APPLICATION OF PULSE COMBUSTION TO INCINERATION OF LIQUID HAZARDOUS WASTE

    Science.gov (United States)

    The report gives results of a study to determine the effect of acoustic pulsations on the steady-state operation of a pulse combustor burning liquid hazardous waste. A horizontal tunnel furnace was retrofitted with a liquid injection pulse combustor that burned No. 2 fuel oil. Th...

  5. Pulse radiolysis of anthraquinone dye aqueous solution

    International Nuclear Information System (INIS)

    Perkowski, J.; Gebicki, J.L.; Lubis, R.; Mayer, J.

    1988-01-01

    Pulse radiolysis of argon flushed aqueous solutions of 10 -5 -10 -4 mol dm -3 anthraquinone dye (C.I. Acid Blue 62) gives rise to the transients originated from the reactions of e - aq , OH and H. The rate constants of these reactions are determined. (author)

  6. Third-harmonic generation in isotropic media by focused pulses

    International Nuclear Information System (INIS)

    Tasgal, Richard S.; Band, Y.B.

    2004-01-01

    For focused pulses of light in isotropic nonlinear media, third-harmonic generation can be strongly affected by group-velocity mismatch between the fundamental and third-harmonic. There is a characteristic time determined by the group-velocity mismatch and the Rayleigh range of the focused pulse. The dynamics depend on two dimensionless quantities, namely the ratio of the characteristic time to the pulse duration and the phase-velocity mismatch times the Rayleigh range. Pulses shorter than the characteristic time have physics described by simple analytic formulas. Pulses near the characteristic time have an intermediate behavior given by an explicit but more complicated formula. Pulses longer than the characteristic time tend to the continuous-wave case

  7. Microstructure and surface mechanical properties of pulse electrodeposited nickel

    Energy Technology Data Exchange (ETDEWEB)

    Ul-Hamid, A., E-mail: anwar@kfupm.edu.sa [Center of Research Excellence in Corrosion (CoRE-C), Research Institute, King Fahd University of Petroleum and Minerals, P.O. Box 1073, Dhahran 31261 (Saudi Arabia); Dafalla, H.; Quddus, A.; Saricimen, H.; Al-Hadhrami, L.M. [Center of Research Excellence in Corrosion (CoRE-C), Research Institute, King Fahd University of Petroleum and Minerals, P.O. Box 1073, Dhahran 31261 (Saudi Arabia)

    2011-09-01

    The surface of carbon steel was modified by electrochemical deposition of Ni in a standard Watt's bath using dc and pulse plating electrodeposition. The aim was to compare the microstructure and surface mechanical properties of the deposit obtained by both techniques. Materials characterization was conducted using field emission scanning electron microscope fitted with scanning transmission electron detector, atomic force microscope and X-ray diffractometer. Nanoindentation hardness, elastic modulus, adhesion, coefficients of friction and wear rates were determined for both dc and pulse electrodeposits. Experimental results indicate that pulse electrodeposition produced finer Ni grains compared to dc plating. Size of Ni grains increased with deposition. Both dc and pulse deposition resulted in grain growth in preferred (2 0 0) orientation. However, presence of Ni (1 1 1) grains increased in deposits produced by pulse deposition. Pulse plated Ni exhibited higher hardness, creep and coefficient of friction and lower modulus of elasticity compared to dc plated Ni.

  8. Femtosecond-Laser-Pulse Characterization and Optimization for CARS Microscopy.

    Directory of Open Access Journals (Sweden)

    Vincenzo Piazza

    Full Text Available We present a simple method and its experimental implementation to determine the pulse durations and linear chirps of the pump-and-probe pulse and the Stokes pulse in a coherent anti-Stokes Raman scattering microscope at sample level without additional autocorrelators. Our approach exploits the delay line, ubiquitous in such microscopes, to perform a convolution of the pump-and-probe and Stokes pulses as a function of their relative delay and it is based on the detection of the photons emitted from an appropriate non-linear sample. The analysis of the non-resonant four-wave-mixing and sum-frequency-generation signals allows for the direct retrieval of the pulse duration on the sample and the linear chirp of each pulse. This knowledge is crucial in maximizing the spectral-resolution and contrast in CARS imaging.

  9. Pulse power modulators - an overview

    International Nuclear Information System (INIS)

    Venkatramani, N.

    2006-01-01

    Pulse power modulators are electronic devices to provide, high voltage, high current, power bursts. Ideally, a modulator, with the means to shape and control the pulses, acts as a switch between a high voltage power supply and its load. This article gives an overview of the pulse power modulators: starting with the basics of pulse and modulation, it covers modulation topologies, different types of modulators, major subsystems and pulse measurement techniques. The various applications of pulse power modulators and the recent trends have been included at the end. (author)

  10. Evaluation of dynamic range for LLNL streak cameras using high contrast pulsed and pulse podiatry on the Nova laser system

    International Nuclear Information System (INIS)

    Richards, J.B.; Weiland, T.L.; Prior, J.A.

    1990-01-01

    This paper reports on a standard LLNL streak camera that has been used to analyze high contrast pulses on the Nova laser facility. These pulses have a plateau at their leading edge (foot) with an amplitude which is approximately 1% of the maximum pulse height. Relying on other features of the pulses and on signal multiplexing, we were able to determine how accurately the foot amplitude was being represented by the camera. Results indicate that the useful single channel dynamic range of the instrument approaches 100:1

  11. Proton Pulse Radiolysis

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, H C; Nilsson, G; Reitberger, T; Thuomas, K A

    1973-03-15

    A 5 MeV proton accelerator (Van de Graaff) has been used for pulse radiolysis of a number of organic gases and the transient spectra obtained from the alkanes methane, ethane, propane, n-butane and neopentane have tentatively been assigned to alkyl radicals. Some methodological aspects of this new technique are discussed

  12. Lectures on pulsed NMR

    International Nuclear Information System (INIS)

    Pines, A.

    1988-08-01

    These lectures discuss some recent developments in pulsed NMR, emphasizing fundamental principles with selected illustrative applications. Major topics covered include multiple-quantum spectroscopy, spin decoupling, the interaction of spins with a quantized field, adiabatic rapid passage, spin temperature and statistics of cross-polarization, coherent averaging, and zero field NMR. 32 refs., 56 figs

  13. Lectures on pulsed NMR

    International Nuclear Information System (INIS)

    Pines, A.

    1986-09-01

    These lectures discuss some recent developments in pulsed NMR, emphasizing fundamental principles with selected illustrative applications. Major topics covered include multiple-quantum spectroscopy, spin decoupling, the interaction of spins with a quantized field, adiabatic rapid passage, spin temperature and statistics of cross-polarization, coherent averaging, and zero field NMR. 55 figs

  14. Pulsed electric fields

    Science.gov (United States)

    The concept of pulsed electric fields (PEF) was first proposed in 1967 to change the behavior or microorganisms. The electric field phenomenon was identified as membrane rupture theory in the 1980s. Increasing the membrane permeability led to the application of PEF assisted extraction of cellular co...

  15. Pulsed inductive HF laser

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  16. Neutronics of pulsed spallation neutron sources

    CERN Document Server

    Watanabe, N

    2003-01-01

    Various topics and issues on the neutronics of pulsed spallation neutron sources, mainly for neutron scattering experiments, are reviewed to give a wide circle of readers a better understanding of these sources in order to achieve a high neutronic performance. Starting from what neutrons are needed, what the spallation reaction is and how to produce slow-neutrons more efficiently, the outline of the target and moderator neutronics are explained. Various efforts with some new concepts or ideas have already been devoted to obtaining the highest possible slow-neutron intensity with desired pulse characteristics. This paper also reviews the recent progress of such efforts, mainly focused on moderator neutronics, since moderators are the final devices of a neutron source, which determine the source performance. Various governing parameters for neutron-pulse characteristics such as material issues, geometrical parameters (shape and dimensions), the target-moderator coupling scheme, the ortho-para-hydrogen ratio, po...

  17. Sequentially pulsed traveling wave accelerator

    Science.gov (United States)

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  18. Pulse pile-up IV

    International Nuclear Information System (INIS)

    Wilkinson, D.H.

    1991-05-01

    The study of pulse pile-up is extended from the case of unipolar pulses, for which ruin theory is an excellent approximation, to the case of bipolar pulses for which ruin theory is not applicable to the effect of the back-kicks in reducing the pile-up: an appropriate solution is presented. (Author) 3 refs., 11 figs

  19. Pulsed electron beam generation with fast repetitive double pulse system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Surender Kumar; Deb, Pankaj; Shyam, Anurag, E-mail: surender80@gmail.com [Energetics and Electromagnetics Division, Bhabha Atomic Research Centre, Visakhapatnam (India); Sharma, Archana [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

  20. Study of laser pulses propagation through an ultrashort pulse amplifying systems for the development of an Offner temporal stretcher

    International Nuclear Information System (INIS)

    Cordeiro, Thiago da Silva

    2009-01-01

    The study of laser pulses propagation through an ultrashort pulses amplifying system containing dispersive and spectral modifying media was performed. The study emphasis was the development of an ultrashort pulse stretcher to replace the one inside a hybrid Ti:Sapphire/Cr:LiSAF CPA system operating at the Center for Lasers and Applications at IPEN/CNEN-SP. A spherical aberration free Offner stretcher was theoretically studied, aiming to obtain a stretching ratio larger than the one available in our system. The influence of the phase components in the amplified pulse final duration was also studied, and the bandwidth limiting elements of the system in operation were mapped, with the purpose of determining the conditions under which a new stretcher should be implemented. Based on the actual measurements, computing routines were implemented in order to determine the consequences of an ultrashort pulse travelling through a bandwidth limiting component. (author)

  1. Pulsed current generator

    International Nuclear Information System (INIS)

    Semenov, V.D.; Furman, Eh.G.

    1974-01-01

    The paper describes a current pulse generator with an auxiliary network consisting of a choke and diode in series designed to enlarge the range of pulse frequency control. One output of the network is connected to an adjustable valve cathode and via antoher auxiliary condenser to the point where the cathode of the main key unit is joined to the start of the magnetizing coil. A second output is connected to the anode of another adjustable valve and via another auxiliary condenser to the point where the anode of the other main key unit is joined to the end of the magnetizing coil. The generator can be used to excite the electromagnets of charged particle accelerators or in devices designed to produce magnetic fields. (author)

  2. Fast pulse amplifier

    International Nuclear Information System (INIS)

    Lepetit, J.; Poussier, E.

    1984-01-01

    This amplifier comprises an inverter transformer, the primary circuit of which receives a pulse and the secondary circuit of which is connected to several amplifying elements in parallel. The inverter transformer is made of coaxial cable segments winded around a magnetic torus; the cable cores connected in series constitute the primary circuit and the braiding of cables, connected in parallel, are the secondary circuit. The transformer comprises, besides, delay lines in series with each braiding of the secondary circuit, these ones are such that pulses issued from each braiding arrive together to the secondary circuit connectors. This invention applies, noticeably in the case of a high voltage amplifier, to the control of deflection blocks of particles used in medicine or in particle accelerators [fr

  3. Linear pulse amplifier

    International Nuclear Information System (INIS)

    Tjutju, R.L.

    1977-01-01

    Pulse amplifier is standard significant part of spectrometer. Apart from other type of amplification, it's a combination of amplification and pulse shaping. Because of its special purpose the device should fulfill the following : High resolution is desired to gain a high yield comparable to its actual state of condition. High signal to noise is desired to nhν resolution. High linearity to facilitate calibration. A good overload recovery, in order to the device will capable of analizing a low energy radiation which appear joinly on the high energy fields. Other expections of the device are its economical and practical use its extentive application. For that reason it's built on a standard NIM principle. Taking also into account the above mentioned considerations. High quality component parts are used throughout, while its availability in the domestic market is secured. (author)

  4. Pulsed fusion reactors

    International Nuclear Information System (INIS)

    1975-01-01

    This summer school specialized in examining specific fusion center systems. Papers on scientific feasibility are first presented: confinement of high-beta plasma, liners, plasma focus, compression and heating and the use of high power electron beams for thermonuclear reactors. As for technological feasibility, lectures were on the theta-pinch toroidal reactors, toroidal diffuse pinch, electrical engineering problems in pulsed magnetically confined reactors, neutral gas layer for heat removal, the conceptual design of a series of laser fusion power plants with ''Saturn'', implosion experiments and the problem of the targets, the high brightness lasers for plasma generation, and topping and bottoming cycles. Some problems common to pulsed reactors were examined: energy storage and transfer, thermomechanical and erosion effects in the first wall and blanket, the problems of tritium production, radiation damage and neutron activation in blankets, and the magnetic and inertial confinement

  5. Short pulse neutron generator

    Science.gov (United States)

    Elizondo-Decanini, Juan M.

    2016-08-02

    Short pulse neutron generators are described herein. In a general embodiment, the short pulse neutron generator includes a Blumlein structure. The Blumlein structure includes a first conductive plate, a second conductive plate, a third conductive plate, at least one of an inductor or a resistor, a switch, and a dielectric material. The first conductive plate is positioned relative to the second conductive plate such that a gap separates these plates. A vacuum chamber is positioned in the gap, and an ion source is positioned to emit ions in the vacuum chamber. The third conductive plate is electrically grounded, and the switch is operable to electrically connect and disconnect the second conductive plate and the third conductive plate. The at least one of the resistor or the inductor is coupled to the first conductive plate and the second conductive plate.

  6. Asymptotic strength of thermal pulses in the helium shell burning

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, M Y [Niigata Univ. (Japan); Sugimoto, D

    1979-03-01

    Secular growth in the strength of the recurrent thermal pulses of helium shell burning is discussed for the purpose of determining its asymptotic strength. It is shown that the pulse grows stronger if the helium zone has been cooled more before the initiation of the pulse. The secular growth of the pulse is related with the increasing degree of cooling. Thermal pulses are computed for an initial model corresponding to the maximum possible cooling, i.e., for a model in which the steady-state entropy distribution was realized in the helium zone. Such thermal pulses are shown to give an upper bound to the asymptotic strength, which is close enough to the asymptotic strength itself for relatively large core masses. Numerical results are given for the core mass of 1.07 M sub(sun), for which the asymptotic strength is found to be 9 x 10/sup 6/ L sub(sun). Thermal pulses are also computed for an initial model which has been cooled artificially more than the steady-state model. The first pulse results in a much greater strength than in the normal model, but a later pulse approaches the normal asymptotic value. Such models are also discussed in relation to the shell flashes on accreting white dwarfs.

  7. Determination of the rate constants of the reactions CO/sub 2/+OH/sup -/ -> HCO/sub 3//sup -/ and barbituric acid -> barbiturate anion -> H/sup -/ using the pulse radiolyse technique

    Energy Technology Data Exchange (ETDEWEB)

    Schuchmann, M.N.; von Sonntag, C.

    1982-09-01

    The kinetics of the reactions of CO/sub 2/ + OH /sup -/-> HCO/sub 3//sup -/ (i) and barbituric acid -> barbiturate anion + H/sup +/ (ii) have been remeasured using as a new approach the pulse radiolysis technique with optical and conductivity detection. The rate constants obtained in the present study, ksub(j) (21/sup 0/C) = 6900 +- 700 M/sup -1/ s/sup -1/ and ksub(II) (19/sup 0/C) = 22 +- 2 s/sup -1/ agree within experimental errors with values obtained earlier by other methods.

  8. Taking the Pulse of Protein Interactions by EPR Spectroscopy

    OpenAIRE

    Cafiso, David S.

    2012-01-01

    An article by Gaffney et al. in this issue establishes a method using pulse electron paramagnetic resonance spectroscopy to determine the location of protein substrates or binding partners with high precision.

  9. Pulsed rf operation analysis

    International Nuclear Information System (INIS)

    Puglisi, M.; Cornacchia, M.

    1981-01-01

    The need for a very low final amplifier output impedance, always associated with class A operation, requires a very large power waste in the final tube. The recently suggested pulsed rf operation, while saving a large amount of power, increases the inherent final amplifier non linearity. A method is presented for avoiding the large signal non linear analysis and it is shown how each component of the beam induced voltage depends upon all the beam harmonics via some coupling coefficients which are evaluated

  10. PULSE Pilot Certification Results

    Directory of Open Access Journals (Sweden)

    Pamela Pape-Lindstrom

    2015-08-01

    Full Text Available The pilot certification process is an ambitious, nationwide endeavor designed to motivate important changes in life sciences education that are in line with the recommendations of the 2011 Vision and Change Report: A Call to Action (American Association for the Advancement of Science [AAAS], 2011.  It is the goal of the certification process to acknowledge departments that have progressed towards full implementation of the tenets of Vision and Change and to motivate departments that have not begun to adopt the recommendations to consider doing so.  More than 70 life science departments applied to be part of the pilot certification process, funded by a National Science Foundation grant, and eight were selected based on initial evidence of transformed and innovative educational practices.  The programs chosen represent a wide variety of schools, including two-year colleges, liberal-arts institutions, regional comprehensive colleges, research universities and minority serving institutions.  Outcomes from this pilot were released June 1, 2015 (www.pulsecommunity.org, with all eight programs being recognized as having progressed along a continuum of change.  Five levels of achievement were defined as PULSE Pilot Progression Levels.  Of the eight departments in the pilot, one achieved “PULSE Progression Level III: Accomplished”.  Six departments achieved “PULSE Progression Level II: Developing” and one pilot department achieved “PULSE Progression Level I: Beginning”.  All of the schools have made significant movement towards the recommendations of Vision and Change relative to a traditional life sciences curriculum.  Overall, the response from the eight pilot schools has been positive. 

  11. STUCTURE OF PULSED BED

    Directory of Open Access Journals (Sweden)

    I. A. Bokun

    2014-01-01

    Full Text Available The structure of pulsed layer is proposed which can be suggested as a state of particulates that is blown by intermittent gas flow with speed which has the force to start material moving. Layer during one cycle is in a suspension, falling down and immobile state resulting in changes of particles arrangement as well as ways of gas flowing through layer. Moreover, it allows carrying out effective interphase heat exchange even adamant real granulation.The process of formation of impact flows is considered aw well as their influence on formation of air bubbles in pulsed layer. At startup of air blast the balance between the force of hydro-dynamic resistance is broken, on one side, and forces of gravity, particles inertia and their links with walls on the other side. The layer is transferred in the state of pulsed pseudo-fluidization, and presents gas-disperse mixture, inside of which impulse of pressure increasing is spreading to all sides as pressure waves (compression. These waves are the sources of impact flows’ formation, the force of which is two times more than during the stationary flow.The waves of pressure are divided into weak and strong ones depending on movement velocity within gas-disperse system. Weak waves are moving with a sound speed and strong ones in active phase of pulsed layer are moving over the speed of sound limit within gas-disperse system. The peculiarity of strong wave is that parameters of system (pressure, density and others are changing in discrete steps.The article describes the regime of layer’s falling down in the passive stage of cycle, which begins after finishing of gas impulse action. And suspension layer of moving up granular material is transferred in the state of falling resulting in change of the layer structure.

  12. Downhole pulse radar

    Science.gov (United States)

    Chang, Hsi-Tien

    1987-09-28

    A borehole logging tool generates a fast rise-time, short duration, high peak-power radar pulse having broad energy distribution between 30 MHz and 300 MHz through a directional transmitting and receiving antennas having barium titanate in the electromagnetically active region to reduce the wavelength to within an order of magnitude of the diameter of the antenna. Radar returns from geological discontinuities are sampled for transmission uphole. 7 figs.

  13. Superconductors for pulsed rf accelerators

    International Nuclear Information System (INIS)

    Campisi, I.E.; Farkas, Z.D.

    1985-04-01

    The choice of superconducting materials for accelerator rf cavities has been determined in the past only in part by basic properties of the superconductors, such as the critical field, and to a larger extent by criteria which include fabrication processes, surface conditions, heat transfer capabilities and so on. For cw operated cavities the trend has been toward choosing materials with higher critical temperatures and lower surface resistance, from Lead to Niobium, from Niobium to Nb 3 Sn. This trend has been dictated by the specific needs of storage ring cw system and by the relatively low fields which could be reached without breakdown. The work performed at SLAC on superconducting cavities using microsecond long high power rf pulses has shown that in Pb, Nb, and Nb 3 Sn fields close to the critical magnetic fields can be reached without magnetic breakdown

  14. Petawatt pulsed-power accelerator

    Science.gov (United States)

    Stygar, William A.; Cuneo, Michael E.; Headley, Daniel I.; Ives, Harry C.; Ives, legal representative; Berry Cottrell; Leeper, Ramon J.; Mazarakis, Michael G.; Olson, Craig L.; Porter, John L.; Wagoner; Tim C.

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  15. Foundations of pulsed power technology

    CERN Document Server

    Lehr, Janet

    2018-01-01

    Pulsed power technologies could be an answer to many cutting-edge applications. The challenge is in how to develop this high-power/high-energy technology to fit current market demands of low-energy consuming applications. This book provides a comprehensive look at pulsed power technology and shows how it can be improved upon for the world of today and tomorrow. Foundations of Pulsed Power Technology focuses on the design and construction of the building blocks as well as their optimum assembly for synergetic high performance of the overall pulsed power system. Filled with numerous design examples throughout, the book offers chapter coverage on various subjects such as: Marx generators and Marx-like circuits; pulse transformers; pulse-forming lines; closing switches; opening switches; multi-gigawatt to multi-terawatt systems; energy storage in capacitor banks; electrical breakdown in gases; electrical breakdown in solids, liquids and vacuum; pulsed voltage and current measurements; electromagnetic interferen...

  16. Bomb pulse radiocarbon dating

    International Nuclear Information System (INIS)

    Tuniz, C.; Zoppi, U.; Hotchkis, M.A.C.

    2004-01-01

    Modern forensic science has to deal not only with homicides and other traditional crimes but also with more global threats such as the smuggling of nuclear materials, clandestine production of weapons of mass destruction, stockpiling of illicit drugs by state controlled groups and war crimes. Forensic applications have always benefited from the use of advanced analytical tools that can characterize materials found at crime scenes. In this paper we will discuss the use of accelerator mass spectrometry (AMS) as an ultrasensitive tool for the crime laboratories of the third millennium. An important objective in forensic science is to order past events chronologically by analysing materials associated with criminal actions. Radiocarbon dating is known to the general public for its application to historical and prehistorical investigations. Examples of forensic significance include the assassination of the Inca Atahualpa by Francisco Pizarro in the early 1530s, the possible murder of the Tyrolean Ice Man (Oetzi) 5300 years ago and the analysis of the burial cloths allegedly associated with the crucifixion of Jesus Christ . Recent murders, including those associated with war crimes in the Balkans during the 1990s, can be studied using 14 C bomb pulse dating. This method has other forensic applications, including investigation of frauds related to food and wine counterfeiting, dating of opium crops and dating of substances used in biological warfare. AMS extends the applicability of the radiocarbon method, allowing the analysis of 14 C in submilligram organic samples. Specific molecular compounds extracted from bones, hair, skin and other carbon bearing substances of forensic significance can now be dated, enhancing the sensitivity and reliability of chronological determinations. AMS can also be used to analyse rare actinide isotopes released into the environment during the clandestine production of nuclear weapons or associated with the smuggling of nuclear materials. In

  17. Validity of the Water Hammer Formula for Determining Regional Aortic Pulse Wave Velocity: Comparison of One-Point and Two-Point (Foot-to-Foot) Measurements Using a Multisensor Catheter in Human.

    Science.gov (United States)

    Hanya, Shizuo

    2013-01-01

    Lack of high-fidelity simultaneous measurements of pressure and flow velocity in the aorta has impeded the direct validation of the water-hammer formula for estimating regional aortic pulse wave velocity (AO-PWV1) and has restricted the study of the change of beat-to-beat AO-PWV1 under varying physiological conditions in man. Aortic pulse wave velocity was derived using two methods in 15 normotensive subjects: 1) the conventional two-point (foot-to-foot) method (AO-PWV2) and 2) a one-point method (AO-PWV1) in which the pressure velocity-loop (PV-loop) was analyzed based on the water hammer formula using simultaneous measurements of flow velocity (Vm) and pressure (Pm) at the same site in the proximal aorta using a multisensor catheter. AO-PWV1 was calculated from the slope of the linear regression line between Pm and Vm where wave reflection (Pb) was at a minimum in early systole in the PV-loop using the water hammer formula, PWV1 = (Pm/Vm)/ρ, where ρ is the blood density. AO-PWV2 was calculated using the conventional two-point measurement method as the distance/traveling time of the wave between 2 sites for measuring P in the proximal aorta. Beat-to-beat alterations of AO-PWV1 in relationship to aortic pressure and linearity of the initial part of the PV-loop during a Valsalva maneuver were also assessed in one subject. The initial part of the loop became steeper in association with the beat-to-beat increase in diastolic pressure in phase 4 during the Valsalva maneuver. The linearity of the initial part of the PV-loop was maintained consistently during the maneuver. Flow velocity vs. pressure in the proximal aorta was highly linear during early systole, with Pearson's coefficients ranging from 0.9954 to 0.9998. The average values of AO-PWV1 and AO-PWV2 were 6.3 ± 1.2 and 6.7 ± 1.3 m/s, respectively. The regression line of AO-PWV1 on AO-PWV2 was y = 0.95x + 0.68 (r = 0.93, p <0.001). This study concluded that the water-hammer formula (one-point method) provides

  18. Development of the pulse transformer for NLC klystron pulse modulator

    International Nuclear Information System (INIS)

    Akemoto, M.; Gold, S.; Koontz, R.; Krasnykh, A.

    1997-05-01

    We have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests are also presented

  19. Pulse transformer R and D for NLC klystron pulse modulator

    International Nuclear Information System (INIS)

    Akemoto, M.; Gold, S.; Krasnykh, A.; Koontz, R.

    1997-07-01

    The authors have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and requires a larger core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and a pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests using a klystron load are also presented

  20. Coiled transmission line pulse generators

    Science.gov (United States)

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  1. High current transistor pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.; Cassel, R.

    1991-05-01

    A solid state pulse generator capable of delivering high current trapezoidally shaped pulses into an inductive load has been developed at SLAC. Energy stored in the capacitor bank of the pulse generator is switched to the load through a pair of Darlington transistors. A combination of diodes and Darlington transistors is used to obtain trapezoidal or triangular shaped current pulses into an inductive load and to recover the remaining energy in the same capacitor bank without reversing capacitor voltage. The transistors work in the switch mode, and the power losses are low. The rack mounted pulse generators presently used at SLAC contain a 660 microfarad storage capacitor bank and can deliver 400 amps at 800 volts into inductive loads up to 3 mH. The pulse generators are used in several different power systems, including pulse to pulse bipolar power supplies and in application with current pulses distributed into different inductive loads. The current amplitude and discharge time are controlled by the central computer system through a specially developed multichannel controller. Several years of operation with the pulse generators have proven their consistent performance and reliability. 8 figs

  2. Characterization of the pulse plasma source

    International Nuclear Information System (INIS)

    Milosavljevic, V; Karkari, S K; Ellingboe, A R

    2007-01-01

    Characterization of the pulse plasma source through the determination of the local thermodynamic equilibrium (LTE) threshold is described. The maximum electron density measured at the peak in discharge current is determined by the width of the He II Paschen alpha spectral line, and the electron temperature is determined from the ratios of the relative intensities of spectral lines emitted from successive ionized stages of atoms. The electron density and temperature maximum values are measured to be 1.3 x 10 17 cm -3 and 19 000 K, respectively. These are typical characteristics for low-pressure, pulsed plasma sources for input energy of 15.8 J at 130 Pa pressure in helium-argon mixture. The use of LTE-based analysis of the emission spectra is justified by measurement of the local plasma electron density at four positions in the discharge tube using a floating hairpin resonance probe. The hairpin resonance probe data are collected during the creation and decay phases of the pulse. From the spatio-temporal profile of the plasma density a 60 μs time-window during which LTE exists throughout the entire plasma source is determined

  3. Elemental analysis using temporal gating of a pulsed neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Mitra, Sudeep

    2018-02-20

    Technologies related to determining elemental composition of a sample that comprises fissile material are described herein. In a general embodiment, a pulsed neutron generator periodically emits bursts of neutrons, and is synchronized with an analyzer circuit. The bursts of neutrons are used to interrogate the sample, and the sample outputs gamma rays based upon the neutrons impacting the sample. A detector outputs pulses based upon the gamma rays impinging upon the material of the detector, and the analyzer circuit assigns the pulses to temporally-based bins based upon the analyzer circuit being synchronized with the pulsed neutron generator. A computing device outputs data that is indicative of elemental composition of the sample based upon the binned pulses.

  4. Active manipulation of the selective alignment by two laser pulses

    International Nuclear Information System (INIS)

    Zeng-Qiang, Yang; Zhi-Rong, Guo; Gui-Xian, Ge

    2010-01-01

    This paper solves numerically the full time-dependent Schrödinger equation based on the rigid rotor model, and proposes a novel strategy to determine the optimal time delay of the two laser pulses to manipulate the molecular selective alignment. The results illustrate that the molecular alignment generated by the first pulse can be suppressed or enhanced selectively, the relative populations of even and odd rotational states in the final rotational wave packet can be manipulated selectively by precisely inserting the peak of the second laser pulse at the time when the slope for the alignment parameter by the first laser locates a local maximum for the even rotational states and a local minimum for the odds, and vice versa. The selective alignment can be further optimised by selecting the intensity ratio of the two laser pulses on the condition that the total laser intensity and pulse duration are kept constant. (atomic and molecular physics)

  5. Versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Adduci, D.J.

    1979-05-01

    A description of the sequence of events and the decisions leading to the design of a versatile pulse programmer for pulsed NMR are presented. Background and application information is discussed in order that the reader might better understand the role of the pulse programmer in a NMR spectrometer. Various other design approaches are presented as a basis for comparison. Specifications for this design are proposed, the hardware implementation of the specifications is discussed, and the software operating system is presented

  6. Versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Adduci, D.J.

    1979-05-01

    A description of the sequence of events and the decisions leading to the design of a versatile pulse programmer for pulsed NMR are presented. Background and application information is discussed in order that the reader might better understand the role of the pulse programmer in a NMR spectrometer. Various other design approaches are presented as a basis for comparison. Specifications for this design are proposed, the hardware implementation of the specifications is discussed, and the software operating system is presented.

  7. Pulsed power for fusion

    International Nuclear Information System (INIS)

    Martin, T.H.

    1976-01-01

    A review which traces the development of high power pulsed accelerators from the original inception at the Atomic Weapons Research Establishment, Aldermaston, England, for Bremsstrahlung output, through the low impedance accelerators, to the double-sided accelerators for fusion will be given. Proto II is presently being assembled at Sandia and preliminary testing on the Marx has been completed. Examples of various techniques will be shown from Sandia accelerators. Requirements for accelerators capable of achieving fusion levels will be developed and problem areas outlined. The diode insulator flashover problem presently limits the maximum current available from the accelerators

  8. A Pulsed Sphere Tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, Dermott E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-01-30

    Here I attempt to explain what physically happens when we pulse an object with neutrons, specifically what we expect the time dependent behavior of the neutron population to look like. Emphasis is on the time dependent emission of both prompt and delayed neutrons. I also describe how the TART Monte Carlo transport code models this situation; see the appendix for a complete description of the model used by TART. I will also show that, as we expect, MCNP and MERCURY, produce similar results using the same delayed neutron model (again, see the appendix).

  9. PULSE SYNTHESIZING GENERATOR

    Science.gov (United States)

    Kerns, Q.A.

    1963-08-01

    >An electronlc circuit for synthesizing electrical current pulses having very fast rise times includes several sinewave generators tuned to progressively higher harmonic frequencies with signal amplitudes and phases selectable according to the Fourier series of the waveform that is to be synthesized. Phase control is provided by periodically triggering the generators at precisely controlled times. The outputs of the generators are combined in a coaxial transmission line. Any frequency-dependent delays that occur in the transmission line can be readily compensated for so that the desired signal wave shape is obtained at the output of the line. (AEC)

  10. Charge pulse preamplifier

    International Nuclear Information System (INIS)

    Libs, Gerard.

    1973-01-01

    A charge pulse preamplifier with very low background noise is described. The inlet stage of that preamplifier comprises a cooled field-effect transistor receiving the signal to be amplified at its gate input. Preferably, the charge resistor of said transistor is a field effect transistor, the source inlet of which is connected to the drain inlet of the former transistor through a self-induction coil and a resistor mounted in series. This can be applied to the treatment of the signals delivered by a particle detector in the form of a semi-conductor [fr

  11. Narrowband pulse-enhanced upconversion of chirped broadband pulses

    International Nuclear Information System (INIS)

    Zhao, Kun; Yuan, Peng; Zhong, Haizhe; Zhang, Dongfang; Zhu, Heyuan; Qian, Liejia; Chen, Liezun; Wen, Shuangchun

    2010-01-01

    We propose and demonstrate an efficient sum-frequency mixing scheme based on narrowband and chirped broadband pulses. It combines the advantages of wider spectral acceptance bandwidth and of alleviating the temporal walk-off, which are both beneficial to higher conversion efficiency. Chirped sum-frequency pulses at 455 nm with energy up to 360 µJ, corresponding to a conversion efficiency of ∼ 40%, are obtained and the pulses can be compressed to ∼ 110 fs. The sum-frequency mixing scheme may provide a promising route to the efficient generation of deep-ultraviolet femtosecond pulses

  12. Integrable discretizations of the short pulse equation

    International Nuclear Information System (INIS)

    Feng Baofeng; Maruno, Ken-ichi; Ohta, Yasuhiro

    2010-01-01

    In this paper, we propose integrable semi-discrete and full-discrete analogues of the short pulse (SP) equation. The key construction is the bilinear form and determinant structure of solutions of the SP equation. We also give the determinant formulas of N-soliton solutions of the semi-discrete and full-discrete analogues of the SP equations, from which the multi-loop and multi-breather solutions can be generated. In the continuous limit, the full-discrete SP equation converges to the semi-discrete SP equation, and then to the continuous SP equation. Based on the semi-discrete SP equation, an integrable numerical scheme, i.e. a self-adaptive moving mesh scheme, is proposed and used for the numerical computation of the short pulse equation.

  13. Attosecond pulse generation in noble gases in the presence of extreme high intensity THz pulses

    International Nuclear Information System (INIS)

    Balogh, E.; Varju, K.

    2010-01-01

    Complete text of publication follows. The shortest - attosecond - light pulses available today are produced by high harmonic generation (HHG) of near-infrared (NIR) laser pulses in noble gas jets, providing a broad spectral plateau of XUV radiation ending in a cutoff. The minimum pulse duration is determined by the achievable bandwidth (i.e. the position of the cutoff), and the chirp of the produced pulses. The extension of the cutoff by increasing the laser intensity is limited by the depletion and phase matching problems of the medium. An alternative method demonstrated to produce higher harmonic orders is by using longer pump pulse wavelength, with the disadvantage of decreased efficiency. Recently it was shown that application of a quasi-DC high strength electric field results in an increase of more than a factor of two in the order of efficiently generated high harmonics. However, the possibility to implement the method proposed in [3] of using a CO 2 laser to create a quasi-DC field for assisting HHG of the NIR laser is questionable, because it's technically very challenging to synchronize pulses from different laser sources. Alternatively, synchronous production of THz pulses with the NIR laser pulse offers a more promising route. The first numerical test of this idea has been reported in [4]. In this contribution we further investigate the method for realistic THz field strengths and short driving pulses, exploring the effect of longer pump laser wavelength on the process. We assume the presence of high intensity THz pulses for supplying the high-strength quasi-DC electric field. The spectrum as well as the chirp of the produced radiation is calculated. We use the non-adiabatic saddle point method to determine the generated radiation described in [6]. We simulate harmonic generation in noble gas atoms, with few cycle NIR pulses of peak intensity at and above 2 x 10 14 W/cm 2 (388 MV/cm) and wavelengths 800 nm and 1560 nm. The THz field strength is varied

  14. Supercoherent phenomena in pulsed power

    International Nuclear Information System (INIS)

    O'Rourke, R.C.

    1983-01-01

    This chapter proposes the formulation of programs of basic physics research to transform Pulsed Power Technology (PPT) to Pulsed Power Science and Technology (PPS and T) by formulating the laws of the quantized microscopic electromagnetic field; applying the microscopic electromagnetic field theory to the generation, propagation and deposition of pulses in nonlinear networks; learning more about the basic super coherent ''micro-structure'' in space and time of the many-photon states of pulsed laser beams; learning more about the basic super coherent ''micro-structure'' in space and time of the many-electronstates of pulsed electron and ion laser beams; and learning everything about the ''micro-picture'' of so-called ''dielectric breakdown'' and the associated absolute time delays. Promotes the idea that laser, electron and ion beams are similar kinds of pulses in the microscopic electromagnetic field. Presents expression for the microscopic electromagnetic field in order to show the role of supercoherence in PPS and T

  15. The role of the waveform in pulse pile-up

    International Nuclear Information System (INIS)

    Datlowe, D.W.

    1977-01-01

    Pulse pile-up is the distortion of pulse-height distributions due to the overlap of detector responses to the arrival of two or more particles or photons within the detector resolving time. This paper presents a computational technique for simulating pile-up effects, which includes explicitly the dependence on the pulse-shape of the detector system. The basis of the technique is the manipulation of probability densities. The method is applicable to all types of linear pulse counting systems for nucleons, electrons, and photons, as long as the result is a pulse-height distribution. The algorithms are highly efficient in the amount of computing required for simulations, and internal checks for the numerical accuracy of the results are included. Studies of pile-up by monoenergetic pulses are used to determine the interrelationship between pulse shapes and spectral features; this information can be used to minimize pile-up. For broad spectra, the square wave approximation is compared with the present model including the correct waveform; introducing the pulse shape information smooths spectral features but does not qualitatively change the spectrum. (Auth.)

  16. Bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  17. Heat driven pulse pump

    Science.gov (United States)

    Benner, Steve M (Inventor); Martins, Mario S. (Inventor)

    2000-01-01

    A heat driven pulse pump includes a chamber having an inlet port, an outlet port, two check valves, a wick, and a heater. The chamber may include a plurality of grooves inside wall of the chamber. When heated within the chamber, a liquid to be pumped vaporizes and creates pressure head that expels the liquid through the outlet port. As liquid separating means, the wick, disposed within the chamber, is to allow, when saturated with the liquid, the passage of only liquid being forced by the pressure head in the chamber, preventing the vapor from exiting from the chamber through the outlet port. A plurality of grooves along the inside surface wall of the chamber can sustain the liquid, which is amount enough to produce vapor for the pressure head in the chamber. With only two simple moving parts, two check valves, the heat driven pulse pump can effectively function over the long lifetimes without maintenance or replacement. For continuous flow of the liquid to be pumped a plurality of pumps may be connected in parallel.

  18. Compensated pulsed alternator

    International Nuclear Information System (INIS)

    Weldon, W.F.; Driga, M.D.; Woodson, H.H.

    1980-01-01

    This invention relates to an electromechanical energy converter with inertial energy storage. The device, a single phase, two or multi-pole alternator with stationary field coils, and a rotating armature is provided. The rotor itself may be of laminated steel for slower pulses or for faster pulses should be nonmagnetic and electrically nonconductive in order to allow rapid penetration of the field as the armature coil rotates. The armature coil comprises a plurality of power generating conductors mounted on the rotor. The alternator may also include a stationary or counterrotating compensating coil to increase the output voltage thereof and to reduce the internal impedance of the alternator at the moment of peak output. As the machine voltage rises sinusoidally, an external trigger switch is adapted to be closed at the appropriate time to create the desired output current from said alternator to an external load circuit, and as the output current passes through zero a self-commutating effect is provided to allow the switch to disconnect the generator from the external circuit

  19. Pulsed neutron sources at KAON

    International Nuclear Information System (INIS)

    Thorson, I.M.; Egelstaff, P.A.; Craddock, M.K.

    1991-01-01

    The proposed KAON Factory facility at TRIUMF consists of a number of synchrotrons and storage rings which offer proton beams of energies between 0.45 and 30 GeV with varying pulse amplitudes, widths and repetition rates. Various possibilities for feeding these beams to a pulsed neutron facility and their potential for future development are examined. The incremental cost of such a pulsed neutron facility is estimated approximately. (author)

  20. Assembly delay line pulse generators

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    Assembly of six of the ten delay line pulse generators that will power the ten kicker magnet modules. One modulator part contains two pulse generators. Capacitors, inductances, and voltage dividers are in the oil tank on the left. Triggered high-pressure spark gap switches are on the platforms on the right. High voltage pulse cables to the kicker magnet emerge under the spark gaps. In the centre background are the assembled master gaps.

  1. Low-intensity pulsed ultrasound: Nonunions

    Directory of Open Access Journals (Sweden)

    Dijkman Bernadette

    2009-01-01

    Full Text Available Nonunions occur in 5-10% of fractures and are characterized by the failure to heal without further intervention. Low intensity pulsed ultrasound therapy has been developed as an alternative to surgery in the treatment of nonunions. We describe a systematic review on trials of low-intensity pulsed ultrasound therapy for healing of nonunions. We searched the electronic databases Medline and the Cochrane library for articles on ultrasound and healing of nonunions published up to 2008. Trials selected for the review met the following criteria: treatment of at least one intervention group with low intensity pulsed ultrasound; inclusion of patients (humans with one or more nonunions (defined as "established" or as a failure to heal for a minimum of eight months after initial injury; and assessment of healing and time to healing, as determined radiographically. The following data were abstracted from the included studies: sample size, ultrasound treatment characteristics, nonunion location, healing rate, time to fracture healing, fracture age, and demographic information. We found 79 potentially eligible publications, of which 14 met our inclusion criteria. Of these, eight studies were used for data abstraction. Healing rates averaged 87%, (range 65.6%-100% among eight trials. Mean time to healing was 146.5 days, (range 56-219 days. There is evidence from trials that low-intensity pulsed ultrasound may be an effective treatment for healing of nonunions. More homogeneous and larger controlled series are needed to further investigate its efficacy.

  2. Experimental study of rf pulsed heating

    Directory of Open Access Journals (Sweden)

    Lisa Laurent

    2011-04-01

    Full Text Available Cyclic thermal stresses produced by rf pulsed heating can be the limiting factor on the attainable reliable gradients for room temperature linear accelerators. This is especially true for structures that have complicated features for wakefield damping. These limits could be pushed higher by using special types of copper, copper alloys, or other conducting metals in constructing partial or complete accelerator structures. Here we present an experimental study aimed at determining the potential of these materials for tolerating cyclic thermal fatigue due to rf magnetic fields. A special cavity that has no electric field on the surface was employed in these studies. The cavity shape concentrates the magnetic field on one flat surface where the test material is placed. The materials tested in this study have included oxygen free electronic grade copper, copper zirconium, copper chromium, hot isostatically pressed copper, single crystal copper, electroplated copper, Glidcop®, copper silver, and silver plated copper. The samples were exposed to different machining and heat treatment processes prior to rf processing. Each sample was tested to a peak pulsed heating temperature of approximately 110°C and remained at this temperature for approximately 10×10^{6} rf pulses. In general, the results showed the possibility of pushing the gradient limits due to pulsed heating fatigue by the use of copper zirconium and copper chromium alloys.

  3. Neutronics of pulsed spallation neutron sources

    International Nuclear Information System (INIS)

    Watanabe, Noboru

    2003-01-01

    Various topics and issues on the neutronics of pulsed spallation neutron sources, mainly for neutron scattering experiments, are reviewed to give a wide circle of readers a better understanding of these sources in order to achieve a high neutronic performance. Starting from what neutrons are needed, what the spallation reaction is and how to produce slow-neutrons more efficiently, the outline of the target and moderator neutronics are explained. Various efforts with some new concepts or ideas have already been devoted to obtaining the highest possible slow-neutron intensity with desired pulse characteristics. This paper also reviews the recent progress of such efforts, mainly focused on moderator neutronics, since moderators are the final devices of a neutron source, which determine the source performance. Various governing parameters for neutron-pulse characteristics such as material issues, geometrical parameters (shape and dimensions), the target-moderator coupling scheme, the ortho-para-hydrogen ratio, poisoning, etc are discussed, aiming at a high performance pulsed spallation source

  4. Insect disinfestation of pulses by irradiation

    International Nuclear Information System (INIS)

    Bhuiya, A.D.; Ahmed, M.; Rezaur, R.; Seal, D.R.; Nahar, G.; Islam, M.M.; Islam, M.S.

    1985-01-01

    Studies were carried out on four varieties of pulses, namely, mosur or lentil (Lens esculenta), mung (Phaseolus aureus), chola or gram (Cirecer aricitinum), and mashkalai (Phaseolus radiatus). Two major burchid betles, Callosobruchus chinensis (L.) and Callosobruchus analis (Fab.), were found to infest different varieties of pulses. Radiation sensitivity of the two pulse beetles was determined at different developmental stages (i.e., eggs, larvae, and pupae). Emergence of adults from eggs totally stopped at a dose of 0.04 kGy. Doses of 0.28 and 0.32 kGy, respectively, were required for complete inhibition of adult emergence from irradiated fourth instar larvae of C. analis and C. chinensis. Studies revealed that the experimental gram was heavily infested (65-91 percent) as compared to other pulses after 8 months of storage in all packaging materials used (gunny bag, gunny bag lined with polyethylene, polyethylene and polyvinyl chloride bags). Mashkalai showed insignificant damage (2-5 percent) by the insects. Reinfestation in the treated products was observed in polyethylene and gunny bags

  5. Light pulse shapes from plastic scintillators

    International Nuclear Information System (INIS)

    Moszynski, M.; Bengtson, B.

    1977-01-01

    A detailed study of the light pulse shape from the binary NE 111 and the ternary Pilot U, Naton 136, KL 236, NE 102A, NE 104 and NE 110 plastic scintillators was performed by the single photon method using XP 1021 and C 31024 photomultipliers. The analysis of the shape of the light pulses determined experimentally for several samples of different dimensions gave the following conclusions. The original light pulse shape from the binary NE 111 scintillator, as measured with a 5 mm thick polished sample is described analytically by the convolution integral of a Gaussian and an exponential function. The Gaussian function may reflect a deexcitation of several higher levels of the solvent molecules excited by nuclear particles preceding an intermolecular energy transfer in the scintillator. It may introduce a rather important limitation of the speed of plastic scintillators as the standard deviation of the Gaussian function is equal to 0.2 ns. The light pulse shape from the ternary plastics is described by the convolution integral of a Gaussian and two exponential functions. The Gaussian function presents the rate of energy transfer from nuclear particles to the primary solute as in the binary plastics. The exponential functions describe the energy transfer from the primary solute to the wavelength shifter and the final emission of the light. (Auth.)

  6. Ultrafast pulse generation in photoconductive switches

    DEFF Research Database (Denmark)

    Keil, Ulrich Dieter Felix; Dykaar, D. R.

    1996-01-01

    Carrier and field dynamics in photoconductive switches are investigated by electrooptic sampling and voltage-dependent reflectivity measurements. We show that the nonuniform field distribution due to the two-dimensional nature of coplanar photoconductive switches, in combination with the large di...... difference in the mobilities of holes and electrons, determine the pronounced polarity dependence. Our measurements indicate that the pulse generation mechanism is a rapid voltage breakdown across the photoconductive switch and not a local field breakdown...

  7. Pulse shape discrimination with fast digitizers

    International Nuclear Information System (INIS)

    Cester, D.; Lunardon, M.; Nebbia, G.; Stevanato, L.; Viesti, G.; Petrucci, S.; Tintori, C.

    2014-01-01

    The pulse shape discrimination (PSD) between neutrons and gamma rays in liquid scintillators is studied by using the charge integration method with fast digitizers having different technical characteristics. The use of the Figure of Merit (FoM) to verify the PSD capability is discussed. The dependence of the FoM on the digitizer sampling rate and resolution is experimentally determined. The effects due to the type of source and the irradiation geometry are also evidenced and discussed

  8. Powerful nanosecond pulse train generator

    International Nuclear Information System (INIS)

    Isakov, I.F.; Logachev, E.I.; Opekunov, M.S.; Pechenkin, S.A.; Remnev, G.E.; Usov, Yu.P.

    1987-01-01

    A generator permitting to shape on the load pulsed with the repetition frequency of 10 3 -10 6 Hz and more is described. The amplitude of shaped voltage pulses is up to 150 kV at pulse duration equal to 50 ns. The generator comprises connected in-series with the load two shaping and two transmission lines realized on the base of the KVI-300 low-ohmic cable. The shaping lines are supplied from two independently connected pulse voltage generators for obtaining time interval between pulses > 10 -6 s; they may be also supplied from one generator for obtaining time interval -6 s. At the expense of reducing losses in the discharge circuit the amplitude of the second pulse grows with increase of time interval between pulses up to 300 ns, further on the curve flat-topping exists. The described generator is used in high-current accelerators, in which the primary negative pulse results in generation of explosive-emission plasma, and the second positive pulse provides ion beam shaping including ions of heavy metal used for production of a potential electrode. The generator multipulse mode is used for successive ion acceleration in the transport system

  9. Single- and multi-pulse femtosecond laser ablation of optical filter materials

    International Nuclear Information System (INIS)

    Krueger, J.; Lenzner, M.; Martin, S.; Lenner, M.; Spielmann, C.; Fiedler, A.; Kautek, W.

    2003-01-01

    Ablation experiments employing Ti:sapphire laser pulses with durations from 30 to 340 fs (centre wavelength 800 nm, repetition rate 1 kHz) were performed in air. Absorbing filters (Schott BG18 and BG36) served as targets. The direct focusing technique was used under single- and multi-pulse irradiation conditions. Ablation threshold fluences were determined from a semi-logarithmic plot of the ablation crater diameter versus laser fluence. The threshold fluence decreases for a shorter pulse duration and an increasing number of pulses. The multi-pulse ablation threshold fluences are similar to those of undoped glass material (∼1 J cm -2 ). That means that the multi-pulse ablation threshold is independent on the doping level of the filters. For more than 100 pulses per spot and all pulse durations applied, the threshold fluence is practically constant. This leads to technically relevant ablation threshold values

  10. Pulse-wave morphology and pulse-wave velocity in healthy human volunteers

    DEFF Research Database (Denmark)

    Frimodt-Møller, M; Nielsen, A H; Kamper, A-L

    2006-01-01

    as smoking caused significant changes in both PWA and PWV parameters and an inter-arm difference was observed. Intra- and interobserver reproducibility was good. CONCLUSIONS: Pulse-wave measurements by applanation tonometry should be undertaken in the same arm during fasting and smoking abstinence.......OBJECTIVE: Applanation tonometry for pulse-wave analysis (PWA) and determination of pulse-wave velocity (PWV) is a non-invasive method for assessment of the central aortic pressure waveform and indices of arterial stiffness. The objective of this study was to examine the influence of eating...... and smoking on PWA and PWV measurements in order to establish standard examination conditions. Furthermore, intra- and interobserver reproducibility and the effects of varying the site of measurements were observed. MATERIAL AND METHODS: Duplicate measurements of the radial pressure waveform...

  11. Background subtraction system for pulsed neutron logging of earth boreholes

    International Nuclear Information System (INIS)

    Hertzog, R.C.

    1983-01-01

    The invention provides a method for determining the characteristics of earth formations surrounding a well borehole comprising the steps of: repetitively irradiating the earth formations surrounding the well bore with relatively short duration pulses of high energy neutrons; detecting during each pulse of high energy neutrons, gamma radiation due to the inelastic scattering of neutrons by materials comprising the earth formations surrounding the borehole and providing information representative thereof; detecting immediately following each such pulse of high energy neutrons, background gamma radiation due to thermal neutron capture and providing information representative thereof; and correcting the inelastic gamma representative information to compensate for said background representative information

  12. Neural pulse frequency modulation of an exponentially correlated Gaussian process

    Science.gov (United States)

    Hutchinson, C. E.; Chon, Y.-T.

    1976-01-01

    The effect of NPFM (Neural Pulse Frequency Modulation) on a stationary Gaussian input, namely an exponentially correlated Gaussian input, is investigated with special emphasis on the determination of the average number of pulses in unit time, known also as the average frequency of pulse occurrence. For some classes of stationary input processes where the formulation of the appropriate multidimensional Markov diffusion model of the input-plus-NPFM system is possible, the average impulse frequency may be obtained by a generalization of the approach adopted. The results are approximate and numerical, but are in close agreement with Monte Carlo computer simulation results.

  13. Laser beam diagnostics for kilowatt power pulsed YAG laser

    International Nuclear Information System (INIS)

    Liu, Yi; Leong, Keng H.

    1992-01-01

    There is a growing need for high power YAG laser beam diagnostics with the recent introduction of such lasers in laser material processing. In this paper, we will describe the use of a commercially available laser beam analyzer (Prometec) to profile the laser beam from a 1600 W pulsed Nd:YAG laser that has a 1 mm fiber optic beam delivery system. The selection of laser pulse frequency and pulse width for the measurement is discussed. Laser beam propagation parameters by various optical components such as fibers and lenses can be determined from measurements using this device. The importance of such measurements will be discussed

  14. Determination of recombination and polarity correction factors, kS and kP, for small cylindrical ionization chambers PTW 31021 and PTW 31022 in pulsed filtered and unfiltered beams.

    Science.gov (United States)

    Bruggmoser, Gregor; Saum, Rainer; Kranzer, Rafael

    2018-01-12

    The aim of this technical communication is to provide correction factors for recombination and polarity effect for two new ionization chambers PTW PinPoint 3D (type 31022) and PTW Semiflex 3D (type 31021). The correction factors provided are for the (based on the) German DIN 6800-2 dosimetry protocol and the AAPM TG51 protocol. The measurements were made in filtered and unfiltered high-energy photon beams in a water equivalent phantom at maximum depth of the PDD and a field size on the surface of 10cm×10cm. The design of the new chamber types leads to an ion collection efficiency and a polarity effect that are well within the specifications requested by pertinent dosimetry protocols including the addendum of TG-51. It was confirmed that the recombination effect of both chambers mainly depends on dose per pulse and is independent of the filtration of the photon beam. Copyright © 2018. Published by Elsevier GmbH.

  15. Determination of the individual electrical and transport properties of the plasmalemma and the tonoplast of the giant marine alga Ventricaria ventricosa by means of the integrated perfusion/charge-pulse technique: evidence for a multifolded tonoplast.

    Science.gov (United States)

    Ryser, C; Wang, J; Mimietz, S; Zimmermann, U

    1999-03-15

    The charge-pulse relaxation spectrum of nonperfused and perfused (turgescent) cells of the giant marine alga Ventricaria ventricosa showed two main exponential decays with time constants of approximately 0.1 msec and 10 msec, respectively, when the cells were bathed in artificial sea water (pH 8). Variation of the external pH did not change the relaxation pattern (in contrast to other giant marine algae). Addition of nystatin (a membrane-impermeable and pore-forming antibiotic) to the vacuolar perfusion solution resulted in the disappearance of the slow exponential, whereas external nystatin decreased dramatically the time constant of the fast one. This indicated (by analogy to corresponding experiments with Valonia utricularis, J. Wang, I. Spiess, C. Ryser, U. Zimmermann, J. Membrane Biol. 157: 311-321, 1997) that the fast relaxation must be assigned to the RC-properties of the plasmalemma and the slow one to those of the tonoplast. Consistent with this, external variation of [K+]o or of [Cl-]o as well as external addition of K+- or Cl--channel/carrier inhibitors (TEA, Ba2+, DIDS) affected only the fast relaxation, but not the slow one. In contrast, addition of these inhibitors to the vacuolar perfusion solution had no measurable effect on the charge-pulse relaxation spectrum. The analysis of the data in terms of the "two membrane model" showed that K+- and (to a smaller extent) Cl--conducting elements dominated the plasmalemma conductance. The analysis of the charge-pulse relaxation spectra also yielded the following area-specific data for the capacitance and the conductance for the plasmalemma and tonoplast (by assuming that both membranes have a planar surface): (plasmalemma) Cp = 0.82 * 10(-2) F m-2, Rp = 1.69 * 10(-2) Omega m2, Gp = 5.9 * 10(4) mS m-2, (tonoplast) Ct = 7. 1 * 10(-2) F m-2, Rt = 14.9 * 10(-2) Omega m2 and Gt = 0.67 * 10(4) mS m-2. The electrical data for the tonoplast show that (in contrast to the literature) the area-specific membrane

  16. New MR pulse sequence

    International Nuclear Information System (INIS)

    Harms, S.E.; Flamig, D.P.; Griffey, R.H.

    1990-01-01

    This paper describes a method for fat suppression for three-dimensional MR imaging. The FATS (fat-suppressed acquisition with echo time shortened) sequence employs a pair of opposing adiabatic half-passage RF pulses tuned on fat resonance. The imaging parameters are as follows: TR, 20 msec; TE, 21.7-3.2 msec; 1,024 x 128 x 128 acquired matrix; imaging time, approximately 11 minutes. A series of 54 examinations were performed. Excellent fat suppression with water excitation is achieved in all cases. The orbital images demonstrate superior resolution of small orbital lesions. The high signal-to-noise ratio (SNR) in cranial studies demonstrates excellent petrous bone and internal auditory canal anatomy

  17. Digital pulse shape discrimination

    International Nuclear Information System (INIS)

    Miller, L. F.; Preston, J.; Pozzi, S.; Flaska, M.; Neal, J.

    2007-01-01

    Pulse-shape discrimination (PSD) has been utilised for about 40 years as a method to obtain estimates for dose in mixed neutron and photon fields. Digitizers that operate close to GHz are currently available at a reasonable cost, and they can be used to directly sample signals from photomultiplier tubes. This permits one to perform digital PSD rather than the traditional, and well-established, analogous techniques. One issue that complicates PSD for neutrons in mixed fields is that the light output characteristics of typical scintillators available for PSD, such as BC501A, vary as a function of energy deposited in the detector. This behaviour is more easily accommodated with digital processing of signals than with analogous signal processing. Results illustrate the effectiveness of digital PSD. (authors)

  18. Pulsed Compression Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Roestenberg, T. [University of Twente, Enschede (Netherlands)

    2012-06-07

    The advantages of the Pulsed Compression Reactor (PCR) over the internal combustion engine-type chemical reactors are briefly discussed. Over the last four years a project concerning the fundamentals of the PCR technology has been performed by the University of Twente, Enschede, Netherlands. In order to assess the feasibility of the application of the PCR principle for the conversion methane to syngas, several fundamental questions needed to be answered. Two important questions that relate to the applicability of the PCR for any process are: how large is the heat transfer rate from a rapidly compressed and expanded volume of gas, and how does this heat transfer rate compare to energy contained in the compressed gas? And: can stable operation with a completely free piston as it is intended with the PCR be achieved?.

  19. Pulse-shaping strategies in short-pulse fiber amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Schimpf, Damian Nikolaus

    2010-02-09

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  20. Pulse-shaping strategies in short-pulse fiber amplifiers

    International Nuclear Information System (INIS)

    Schimpf, Damian Nikolaus

    2010-01-01

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  1. Repeated pulsed x-ray emission equipment

    International Nuclear Information System (INIS)

    Terauchi, Hikaru; Iida, Satoshi

    1982-01-01

    X-ray diffraction technique has been applied to determine the spatial positions of atoms which compose a material, and it is needless to say that the technique is a fundamental means regardless of the fields of research. However, the application of X-ray diffraction to the research on physical properties has been so far limited to know the spatial positions of atoms or molecules under thermal equilibrium condition. The addition of time element to the conventional technique, that is, the analysis of material structure including the time-varying processes under non-equilibrium conditions, is considered to approach the elucidation of the essence of materials. The authors call this dynamic structural analysis. The authors have planned to analyze X-ray diffraction intensity which has the resolution of about 10 -8 s in the real time which is conjugate with energy. However, present pulsed X-ray sources are not suitable for diffraction experiment because the pulse width is too long or X-ray wavelength is too short. Accordingly, the authors have made for trial a pulsed X-ray source for diffraction experiment. Its specifications are: diode voltage (X-ray tube voltage) from 200 to 300 kV, diode current from 2 to 5 kA, pulse width of about 30ns, maximum repetition frequency 10 pps, and X-ray focus size of 2 mm diameter. One of the features of this source is the repeated generation of pulsed X-ray. This is the first trial in the world, and is indispensable to the dynamic structural analysis described above. The quality of the emitted X-ray is also written. (Wakatsuki, Y.)

  2. A Radiation Dosimetry Method Using Pulsed Optically Stimulated Luminescence

    International Nuclear Information System (INIS)

    Akselrod, M.S.; McKeever, S.W.S.

    1999-01-01

    A method for the determination of absorbed radiation dose is described based on pulsed optically stimulated luminescence (POSL). The method relies upon the stimulation of an irradiated sample with a train of light pulses from a suitable light source (e.g. a laser) using a wavelength which is within the range of wavelengths corresponding to the radiation-induced optical absorption in the irradiated sample. The subsequent emitted light, due to the detrapping of trapped charges and their subsequent recombination with charge of the opposite sign, is synchronously detected in the period between each stimulation pulse. The total luminescence is summed over the desired number of stimulation pulses and this forms the measured POSL signal. By monitoring the emitted light only in the period between stimulation pulses one can reduce the optical filtering required to discriminate between the stimulation light and the emission light; in this way a high measurement efficiency, and, therefore, a high radiation sensitivity (luminescence intensity per unit absorbed dose) is achieved. Key parameters in the method are the intrinsic luminescence lifetime for the material being used as the luminescent detector, the width of the optical stimulation pulse, and the period between pulses. For optimum operation the measurement parameters should be such that both the pulse width and the time between pulses are much less than the luminescence lifetime. By appropriate choice of the power of the optical stimulation, the frequency of the stimulation pulses, and the total stimulation period, one can also re-measure the absorbed dose several times. In this way, a re-read capability is available with the procedure. The method is illustrated using light from a 2nd-harmonic Nd:YAG laser, with irradiated, anion-deficient aluminium oxide as the luminescent detector material. (author)

  3. Electrical pulse burnout of transistors in intense ionizing radiation

    International Nuclear Information System (INIS)

    Hartman, E.F.; Evans, D.C.

    1975-01-01

    Tests examining possible synergistic effects of electrical pulses and ionizing radiation on transistors were performed and energy/power thresholds for transistor burnout determined. The effect of ionizing radiation on burnout thresholds was found to be minimal, indicating that electrical pulse testing in the absence of radiation produces burnout-threshold results which are applicable to IEMP studies. The conditions of ionized transistor junctions and radiation induced current surges at semiconductor device terminals are inherent in IEMP studies of electrical circuits

  4. The Vulcan pulse generating system

    International Nuclear Information System (INIS)

    Danson, C.N.; Edwards, C.B.; Wyatt, R.W.W.

    1985-01-01

    During the past two years several changes have been made to the front end system on the VULCAN pulse generating system. These changes give greater flexibility and a wider choice of operating conditions. This note gives an updated description of the system capabilities, and gives users of the facility an idea of the various pulse combinations that are available. (author)

  5. NMR in pulsed magnetic field

    KAUST Repository

    Abou-Hamad, Edy; Bontemps, P.; Rikken, Geert L J A

    2011-01-01

    Nuclear magnetic resonance (NMR) experiments in pulsed magnetic fields up to 30.4 T focused on 1H and 93Nb nuclei are reported. Here we discuss the advantage and limitation of pulsed field NMR and why this technique is able to become a promising research tool. © 2011 Elsevier Inc. All Rights Reserved.

  6. Progress in pulsed power fusion

    Energy Technology Data Exchange (ETDEWEB)

    Quintenz, J P; Adams, R G; Bailey, J E [Sandia Labs., Albuquerque, NM (United States); and others

    1997-12-31

    Pulsed power offers an efficient, high energy, economical source of x-rays for inertial confinement fusion (ICF) research. Two main approaches to ICF driven with pulsed power accelerators are pursued: intense light ion beams and z-pinches. Recent progress in each approach and plans for future development is described. (author). 2 figs., 10 refs.

  7. NMR in pulsed magnetic field

    KAUST Repository

    Abou-Hamad, Edy

    2011-09-01

    Nuclear magnetic resonance (NMR) experiments in pulsed magnetic fields up to 30.4 T focused on 1H and 93Nb nuclei are reported. Here we discuss the advantage and limitation of pulsed field NMR and why this technique is able to become a promising research tool. © 2011 Elsevier Inc. All Rights Reserved.

  8. A Single-Pulse Integrator

    DEFF Research Database (Denmark)

    Miller, Arne

    1974-01-01

    A single-pulse integrator is described. It gives a relative measure of the integral of the output signal from a coil monitor on the Risø 10 MeV linear accelerator, and displays the value on a digital voltmeter. The reproduccibility is found to be better than ±1% for an accelerated pulse charge...

  9. Progress in pulsed power fusion

    International Nuclear Information System (INIS)

    Quintenz, J.P.; Adams, R.G.; Bailey, J.E.

    1996-01-01

    Pulsed power offers an efficient, high energy, economical source of x-rays for inertial confinement fusion (ICF) research. Two main approaches to ICF driven with pulsed power accelerators are pursued: intense light ion beams and z-pinches. Recent progress in each approach and plans for future development is described. (author). 2 figs., 10 refs

  10. High-power pre-chirp managed amplification of femtosecond pulses at high repetition rates

    International Nuclear Information System (INIS)

    Liu, Yang; Li, Wenxue; Zhao, Jian; Bai, Dongbi; Luo, Daping; Zeng, Heping

    2015-01-01

    Femtosecond pulses at 250 MHz repetition rate from a mode-locked fiber laser are amplified to high power in a pre-chirp managed amplifier. The experimental strategy offers a potential towards high-power ultrashort laser pulses at high repetition rates. By investigating the laser pulse evolution in the amplification processes, we show that self-similar evolution, finite gain bandwidth and mode instabilities determine pulse characteristics in different regimes. Further average power scaling is limited by the mode instabilities. Nevertheless, this laser system enables us to achieve sub-50 fs pulses with an average power of 93 W. (letter)

  11. Electromagnetic pulses, localized and causal

    Science.gov (United States)

    Lekner, John

    2018-01-01

    We show that pulse solutions of the wave equation can be expressed as time Fourier superpositions of scalar monochromatic beam wave functions (solutions of the Helmholtz equation). This formulation is shown to be equivalent to Bateman's integral expression for solutions of the wave equation, for axially symmetric solutions. A closed-form one-parameter solution of the wave equation, containing no backward-propagating parts, is constructed from a beam which is the tight-focus limit of two families of beams. Application is made to transverse electric and transverse magnetic pulses, with evaluation of the energy, momentum and angular momentum for a pulse based on the general localized and causal form. Such pulses can be represented as superpositions of photons. Explicit total energy and total momentum values are given for the one-parameter closed-form pulse.

  12. Effect of laser pulse parameters on the size and fluorescence of nanodiamonds formed upon pulsed-laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Peikang [School of Materials Science and Engineering, North University of China, Taiyuan 030051 (China); Hu, Shengliang, E-mail: hsliang@yeah.net [Key Laboratory of Instrumentation Science and Dynamic Measurement (North University of China), Ministry of Education, National Key Laboratory Science and Technology on Electronic Test and Measurement, Taiyuan 030051 (China); School of Materials Science and Engineering, North University of China, Taiyuan 030051 (China); Zhang, Taiping; Sun, Jing [School of Materials Science and Engineering, Tianjin University, Tianjin 300072 (China); Cao, Shirui [School of Materials Science and Engineering, North University of China, Taiyuan 030051 (China)

    2010-07-15

    The size of nanodiamonds formed upon laser irradiation could be easily controlled over simply adjusting laser pulse parameters. The stable size and structure of nanodiamonds were mostly determined by laser power density and pulse width. Both large nanodiamonds with multiply twinning structure (MTS) and small nanodiamonds with single crystalline structure (SCS) emitted strong visible light after surface passivation, and their fluorescence quantum yield (QY) was 4.6% and 7.1%, respectively.

  13. Effect of laser pulse parameters on the size and fluorescence of nanodiamonds formed upon pulsed-laser irradiation

    International Nuclear Information System (INIS)

    Bai, Peikang; Hu, Shengliang; Zhang, Taiping; Sun, Jing; Cao, Shirui

    2010-01-01

    The size of nanodiamonds formed upon laser irradiation could be easily controlled over simply adjusting laser pulse parameters. The stable size and structure of nanodiamonds were mostly determined by laser power density and pulse width. Both large nanodiamonds with multiply twinning structure (MTS) and small nanodiamonds with single crystalline structure (SCS) emitted strong visible light after surface passivation, and their fluorescence quantum yield (QY) was 4.6% and 7.1%, respectively.

  14. Cubic phase control of ultrashort laser pulses

    International Nuclear Information System (INIS)

    Mecseki, K.; Erdelyi, M.; Kovacs, A.P.; Szabo, G.

    2006-01-01

    the 40 μrad/nm value. For experimental verification, the cubic compressor was placed in one arm of a Michelson-type interferometer illuminated by a Ti:sapphire oscillator providing 20 fs (FWHM) pulses at a central wavelength of 800 nm. The compressor consisted of a calcite crystal with a radius of 15 nm and an achromatic lens with a magnification of 4 in accordance with the simulation results. The dispersion coefficients of the compressor were determined from the spectrally resolved interferograms (SRI). During the experiments, special attention was paid to minimizing the angular dispersion of the pulse leaving the compressor. The measured GDD and TOD were 3.8 x 10 3 fs 2 and -2.6 x 10 5 fs 3 , while the calculated values were 3.2 x 10 3 fs 2 and -1.9 x 10 5 fs 3 , respectively. Taking into consideration the paraxial approximation based simulation, the 25% average error of the dispersion values is acceptable. The simulation results can be used as rough estimation, and SRI can be applied for real-time fine tuning.

  15. Complex Nanostructures by Pulsed Droplet Epitaxy

    Directory of Open Access Journals (Sweden)

    Noboyuki Koguchi

    2011-06-01

    Full Text Available What makes three dimensional semiconductor quantum nanostructures so attractive is the possibility to tune their electronic properties by careful design of their size and composition. These parameters set the confinement potential of electrons and holes, thus determining the electronic and optical properties of the nanostructure. An often overlooked parameter, which has an even more relevant effect on the electronic properties of the nanostructure, is shape. Gaining a strong control over the electronic properties via shape tuning is the key to access subtle electronic design possibilities. The Pulsed Dropled Epitaxy is an innovative growth method for the fabrication of quantum nanostructures with highly designable shapes and complex morphologies. With Pulsed Dropled Epitaxy it is possible to combine different nanostructures, namely quantum dots, quantum rings and quantum disks, with tunable sizes and densities, into a single multi-function nanostructure, thus allowing an unprecedented control over electronic properties.

  16. Pulsed power particle beam fusion research

    International Nuclear Information System (INIS)

    Yonas, G.

    1979-01-01

    Although substantial progress has been made in the last few years in developing the technology of intense particle beam drivers, there are still several unanswered questions which will determine their ultimate feasibility as fusion ignition systems. The questions of efficiency, cost, and single pulse scalability appear to have been answered affirmatively but repetitive pulse technology is still in its infancy. The allowable relatively low pellet gains and high available beam energies should greatly ease questions of pellet implosion physics. Insofar as beam-target coupling is concerned, ion deposition is thought to be understood and our measurements of enhanced electron deposition agree with theory. With the development of plasma discharges for intense beam transport and concentration it appears that light ion beams will be the preferred approach for reactors

  17. Laser Pulse Heating of Spherical Metal Particles

    Directory of Open Access Journals (Sweden)

    Michael I. Tribelsky

    2011-12-01

    Full Text Available We consider the general problem of laser pulse heating of spherical metal particles with the sizes ranging from nanometers to millimeters. We employ the exact Mie solution of the diffraction problem and solve the heat-transfer equation to determine the maximum temperature rise at the particle surface as a function of optical and thermometric parameters of the problem. Primary attention is paid to the case when the thermal diffusivity of the particle is much larger than that of the environment, as it is in the case of metal particles in fluids. We show that, in this case, for any given duration of the laser pulse, the maximum temperature rise as a function of the particle size reaches a maximum at a certain finite size of the particle. We suggest simple approximate analytical expressions for this dependence, which cover the entire parameter range of the problem and agree well with direct numerical simulations.

  18. Pulsed neutron generator for use with pulsed neutron activation techniques

    International Nuclear Information System (INIS)

    Rochau, G.E.

    1980-01-01

    A high-output, transportable, pulsed neutron generator has been developed by Sandia National Laboratories for use with Pulsed Neutron Activation (PNA) techniques. The PNA neutron generator generates > 10 10 14 MeV D-T neutrons in a 1.2 millisecond pulse. Each operation of the unit will produce a nominal total neutron output of 1.2 x 10 10 neutrons. The generator has been designed to be easily repaired and modified. The unit requires no additional equipment for operation or measurement of output

  19. Laser ablation comparison by picosecond pulses train and nanosecond pulse

    Science.gov (United States)

    Lednev, V. N.; Filippov, M. N.; Bunkin, A. F.; Pershin, S. M.

    2015-12-01

    A comparison of laser ablation by a train of picosecond pulses and nanosecond pulses revealed a difference in laser craters, ablation thresholds, plasma sizes and spectral line intensities. Laser ablation with a train of picosecond pulses resulted in improved crater quality while ablated mass decreased up to 30%. A reduction in laser plasma dimensions for picosecond train ablation was observed while the intensity of atomic/ionic lines in the plasma spectra was greater by a factor of 2-4 indicating an improved excitation and atomization in the plasma.

  20. Pulse on pulse: modulation and signification in Rafael Lozano-Hemmer's Pulse Room

    Directory of Open Access Journals (Sweden)

    Merete Carlson

    2012-06-01

    Full Text Available This article investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006 by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy of the visitor's beating heart to the flashing of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the flashing light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant and pulsating “room”. Hence, the visitor in Pulse Room is invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic “rhythm of life” and instants of pure material processuality (flickering light bulbs; polyrhythmic layers. Taking our point of departure in a discussion of Gilles Deleuze's concepts of modulation and signaletic material in relation to electronic media, we examine how the complex orchestration of pulsation between signification and material modulation produces a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, a relational subject–object intimacy and an all-encompassing immersive environment modulating continuously in real space-time.

  1. Pulse shaping using a spatial light modulator

    CSIR Research Space (South Africa)

    Botha, N

    2009-07-01

    Full Text Available Femtosecond pulse shaping can be done by different kinds of pulse shapers, such as liquid crystal spatial light modulators (LC SLM), acousto optic modulators (AOM) and deformable and movable mirrors. A few applications where pulse shaping...

  2. Properties of gamma-ray burst time profiles using pulse decomposition analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, A.

    2000-02-08

    The time profiles of many gamma-ray bursts consist of distinct pulses, which offers the possibility of characterizing the temporal structure of these bursts using a relatively small set of pulse shape parameters. This pulse decomposition analysis has previously been performed on a small sample of bright long bursts using binned data from BATSE, which comes in several data types, and on a sample of short bursts using the BATSE Time-Tagged Event (TTE) data type. The authors have developed an interactive pulse-fitting program using the phenomenological pulse model of Norris, et. al. and a maximum-likelihood fitting routine. They have used this program to analyze the Time-to-Spill (TTS) data for all bursts observed by BATSE up through trigger number 2000, in all energy channels for which TTS data is available. They present statistical information on the attributes of pulses comprising these bursts, including relations between pulse characteristics through the course of a burst. They carry out simulations to determine the biases that their procedures may introduce. They find that pulses tend to have shorter rise times than decay times, and tend to be narrower and peak earlier at higher energies. They also find that pulse brightness, pulse width, and pulse hardness ratios do not evolve monotonically within bursts, but that the ratios of pulse rise times to decay times tends to decrease with time within bursts.

  3. Capacitor charging FET switcher with controller to adjust pulse width

    Science.gov (United States)

    Mihalka, Alex M.

    1986-01-01

    A switching power supply includes an FET full bridge, a controller to drive the FETs, a programmable controller to dynamically control final output current by adjusting pulse width, and a variety of protective systems, including an overcurrent latch for current control. Power MOSFETS are switched at a variable frequency from 20-50 kHz to charge a capacitor load from 0 to 6 kV. A ferrite transformer steps up the DC input. The transformer primary is a full bridge configuration with the FET switches and the secondary is fed into a high voltage full wave rectifier whose output is connected directly to the energy storage capacitor. The peak current is held constant by varying the pulse width using predetermined timing resistors and counting pulses. The pulse width is increased as the capacitor charges to maintain peak current. A digital ripple counter counts pulses, and after the desired number is reached, an up-counter is clocked. The up-counter output is decoded to choose among different resistors used to discharge a timing capacitor, thereby determining the pulse width. A current latch shuts down the supply on overcurrent due to either excessive pulse width causing transformer saturation or a major bridge fault, i.e., FET or transformer failure, or failure of the drive circuitry.

  4. Generation of Quasi-Gaussian Pulses Based on Correlation Techniques

    Directory of Open Access Journals (Sweden)

    POHOATA, S.

    2012-02-01

    Full Text Available The Gaussian pulses have been mostly used within communications, where some applications can be emphasized: mobile telephony (GSM, where GMSK signals are used, as well as the UWB communications, where short-period pulses based on Gaussian waveform are generated. Since the Gaussian function signifies a theoretical concept, which cannot be accomplished from the physical point of view, this should be expressed by using various functions, able to determine physical implementations. New techniques of generating the Gaussian pulse responses of good precision are approached, proposed and researched in this paper. The second and third order derivatives with regard to the Gaussian pulse response are accurately generated. The third order derivates is composed of four individual rectangular pulses of fixed amplitudes, being easily to be generated by standard techniques. In order to generate pulses able to satisfy the spectral mask requirements, an adequate filter is necessary to be applied. This paper emphasizes a comparative analysis based on the relative error and the energy spectra of the proposed pulses.

  5. Pulsed-linac synchronization using an embedded micro-controller

    International Nuclear Information System (INIS)

    Craig, S.R.; Alexander, S.B.; West, R.J.; Simpson, M.P.

    1992-01-01

    A Master Timing Generator (MTG) was developed using a single Motorola MC68332 embedded micro-controller. The MTG produces electrical synchronization pulses that coordinate the action of all pulsed subsystems and the acquisition of pulsed data. Pulse width and delay-offset of each of the 13 output channels can be changed on-line. The MTG is interfaced with a GE Series-Six Programmable Logic Controller (PLC), which coordinates overall control of the IMPELA linac. Serial communications are used between the PLC and the MTG. The PLC needs only to transmit data to define the pulse repetition rate, the beam pulse width, and the subsystems that should be active. The MTG determines the widths and relative delays required to achieve the requested beam pulse-width. Changes in width and repetition rate are effected using a smooth ramp to avoid power-demand transients. All MTG timing requirements are met with the current implementation, having the following characteristics: 1 Hz ≤ repetition rate ≤ 500 Hz with ±1% resolution, 12 μs ≤ width ≤ 1000 μs in 1 μs steps, and a delay-offset range of 4.5 ms in 1 μs steps. (Author) (4 figs., 5 refs.)

  6. Interaction of Rydberg atoms with two contrapropagating ultrashort laser pulses

    International Nuclear Information System (INIS)

    Lugovskoy, A. V.; Bray, I.

    2006-01-01

    In this paper we investigate how Rydberg atoms respond to perturbation by two contrapropagating ultrashort laser pulses. We consider the case where the durations of both pulses τ 1 and τ 2 are shorter than the inverse of the initial-state energy ε i -1 . When acting alone such a pulse passes through the atom without noticeable alteration in the atomic state. The situation is different if two such pulses interfere in the region of atom localization. In this case the atomic response is significantly enhanced. This is due to the nonzero momentum transferred to the electron by the interplay of the electric field of one pulse and the magnetic field of the other. The sudden perturbation approximation is used to evaluate the transition probabilities. They are shown to depend on the atom position with respect to the pulse interference region. This dependence is determined by the relationship between the atomic diameter d i and the interference-region size l=c(τ 1 +τ 2 ) (c is the speed of light). If d i i >>l the transition probabilities are sensitive to the electron density distribution along the propagation direction. The probabilities of the initial-state destruction and atom ionization drop as l/d i irrespective of the characteristics of the pulses

  7. Detection of movement artifact in recorded pulse oximeter saturation.

    Science.gov (United States)

    Poets, C F; Stebbens, V A

    1997-10-01

    Movement artifact (MA) must be detected when analysing recordings of pulse oximeter saturation (SpO2). Visual analysis of individual pulse waveforms is the safest, but also the most tedious, method for this purpose. We wanted to test the reliability of a computer algorithm (Edentec Motion Annotation System), based on a comparison between pulse and heart rate, for MA detection. Ten 12-h recordings of SpO2, pulse waveforms and heart rate from ten preterm infants were analysed for the presence of MA on the pulse waveform signal. These data were used to determine the sensitivity and specificity of the computer algorithm, and of the oximeter itself, in detecting MA. Recordings were divided into segments of 2.5 s duration to compare the movement identification methods. Of the segments 31% +/- 6% (mean +/- SD) contained MA. The computer algorithm identified 95% +/- 3% of these segments, the pulse oximeter only 18% +/- 11%. Specificity was 85% +/- 4% and 99% +/- 0%, respectively. SpO2 was signal showed MA during this time, leaving a significant potential for erroneous identification of hypoxaemia. Recordings of SpO2 do not allow a reliable identification of MA. Without additional information about movement artifact, a significant proportion of recording time of pulse oximeter signal may be regarded as demonstrating hypoxaemia which, in fact, simply reflects poor measurement conditions. The computer algorithm used in this study identified periods of movement artifact reliably.

  8. Structure of pulsed plasma jets

    International Nuclear Information System (INIS)

    Cavolowsky, J.A.

    1987-01-01

    A pulsed plasma jet is a turbulent, inhomogeneous fluid mechanical discharge capable of initiating and enhancing combustion. Having shown the ability to ignite lean fuel mixtures, it now offers the potential for real-time control of combustion processes. This study explored the fluid-mechanical and chemical properties of such jets. The fluid-mechanical structure of the jet was examined using two optical diagnostic techniques. Self-light streak photography provided information on the motion of luminous gas particles in its core. It revealed that plasma jets behave either totally subsonic or embody a supersonic core. The turbulent, thermal evolution of the jet was explored using high-speed-laser schlieren cinematography. By examining plasma jet generators with both opaque and transparent plasma cavities, detailed information on plasma formation and jet structure, beginning with the electric arc discharge in the cavity, was obtained. These records revealed the production of thermal stratifications in the cavity that could account for the plasma particles in the jet core. After the electrical discharges ceased, the turbulent jet behaved as a self-similar plume. Molecular-beam mass spectrometry was used to determine temperature and species concentration in the jet. Both non-combustible and combustible jets were studied

  9. Method for determining efficiency in a liquid scintillation system

    International Nuclear Information System (INIS)

    Laney, B.H.

    1975-01-01

    In a liquid scintillation system utilizing plural photomultiplyier means, a method for determining efficiency of coincident pulse detection. Various incremental counting efficiency levels are associated with asymptotic functions in a two dimension matrix in which the abscissa and ordinate correspond to the pulse heights of each of a pair of coincident pulses from different photomultiplier means. An efficiency determining point is located in the matrix based on the sum of the pulse heights of each of the coincident pulses as well as on the amplitude of the smallest pulse of the coincident pulses. The single counting efficiency determining point is recorded as the level of efficiency at which the photomultiplier means detect scintillations that generate coincident pulses having pulse heights equal to those recorded. (Patent Office Record)

  10. Bomb pulse biology

    Energy Technology Data Exchange (ETDEWEB)

    Falso, Miranda J. Sarachine [Center for Accelerator Mass Spectrometry, Mail Stop L-397, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States); Buchholz, Bruce A., E-mail: buchholz2@llnl.gov [Center for Accelerator Mass Spectrometry, Mail Stop L-397, Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, CA 94551 (United States)

    2013-01-15

    The past decade has seen an explosion in use of the {sup 14}C bomb pulse to do fundamental cell biology. Studies in the 1960s used decay counting to measure tissue turnover when the atmospheric {sup 14}C/C concentration was changing rapidly. Today bulk tissue measurements are of marginal interest since most of the carbon in the tissue resides in proteins, lipids and carbohydrates that turn over rapidly. Specific cell types with specialized functions are the focus of cell turnover investigations. Tissue samples need to be fresh or frozen. Fixed or preserved samples contain petroleum-derived carbon that has not been successfully removed. Cell or nuclear surface markers are used to sort specific cell types, typically by fluorescence-activated cell sorting (FACS). Specific biomolecules need to be isolated with high purity and accelerator mass spectrometry (AMS) measurements must accommodate samples that generally contain less than 40 {mu}g of carbon. Furthermore, all separations must not add carbon to the sample. Independent means such as UV absorbance must be used to confirm molecule purity. Approaches for separating specific proteins and DNA and combating contamination of undesired molecules are described.

  11. Pulsed radiation decay logging

    International Nuclear Information System (INIS)

    Mills, W.R. Jr.

    1983-01-01

    There are provided new and improved well logging processes and systems wherein the detection of secondary radiation is accomplished during a plurality of time windows in a manner to accurately characterize the decay rate of the secondary radiation. The system comprises a well logging tool having a primary pulsed radiation source which emits repetitive time-spaced bursts of primary radiation and detector means for detecting secondary radiation resulting from the primary radiation and producing output signals in response to the detected radiation. A plurality of measuring channels are provided, each of which produces a count rate function representative of signals received from the detector means during successive time windows occurring between the primary radiation bursts. The logging system further comprises means responsive to the measuring channels for producing a plurality of functions representative of the ratios of the radiation count rates measured during adjacent pairs of the time windows. Comparator means function to compare the ratio functions and select at least one of the ratio functions to generate a signal representative of the decay rate of the secondary radiation

  12. NEMP (Nuclear Electromagnetic Pulse)

    International Nuclear Information System (INIS)

    Grunow, H.K.

    The variety of measures discussed in this contribution can be used to achieve with minimum effort a damping of 10 6 :1 (120 dB) between the interfering pulses in the networks and lines outside the buildings and the lines leading to the semiconductors. Expert knowledge, experience, and insight into the systems are required to solve this task optimally. The procedure to be adopted for NEMP protection differs only slightly from that used for achieving electromagnetic compatibility and lightning protection. Industry has developed the equipment for overvoltage protection and offers graded protection systems, experienced experts and systems engineers are available. This potential of the industry could be used to sponsor a pilot project, e.g. by public research funds. One of the goals of such a project could be to work out reliable data for cost estimated for large projects. Even if one would not accept the hypothetical probability of a nuclear war as a reason good anough to start such a project, it would not be justified to deny the necessity of additional expenditure for setting up a ''NEMP emergency system'' for protection waterborne traffic on purely financial grounds. (orig./RW) [de

  13. Measurements of picosecond pulses of a high-current electron accelerator

    International Nuclear Information System (INIS)

    Zheltov, K.A.; Petrenko, A.N.; Turundaevskaya, I.G.; Shalimanov, V.F.

    1997-01-01

    The duration of a picosecond high-current accelerator electron beam pulse duration is measured and its shape is determined using a measuring line, comprising a Faraday cup, a radiofrequency cable of minor length and a wide-band SRG-7 oscillograph. The procedure of data reconstruction according to regularization method is applied to determine the actual shape of the pulse measured

  14. Magnetic Alignment of Pulsed Solenoids Using the Pulsed Wire Method

    International Nuclear Information System (INIS)

    Arbelaez, D.; Madur, A.; Lipton, T.M.; Waldron, W.L.; Kwan, J.W.

    2011-01-01

    A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 (micro)m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.

  15. Pulsed ultrasonic stir welding method

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    A method of performing ultrasonic stir welding uses a welding head assembly to include a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. In the method, the rod is rotated about its longitudinal axis during a welding operation. During the welding operation, a series of on-off ultrasonic pulses are applied to the rod such that they propagate parallel to the rod's longitudinal axis. At least a pulse rate associated with the on-off ultrasonic pulses is controlled.

  16. Pulse timing for cataclysmic variables

    International Nuclear Information System (INIS)

    Chester, T.J.

    1979-01-01

    It is shown that present pulse timing measurements of cataclysmic variables can be explained by models of accretion disks in these systems, and thus such measurements can constrain disk models. The model for DQ Her correctly predicts the amplitude variation of the continuum pulsation and can also perhaps explain the asymmetric amplitude of the pulsed lambda4686 emission line. Several other predictions can be made from the model. In particular, if pulse timing measurements that resolve emission lines both in wavelength and in binary phase can be made, the projected orbital radius of the white dwarf could be deduced

  17. Hyper dispersion pulse compressor for chirped pulse amplification systems

    Science.gov (United States)

    Barty, Christopher P. J.

    2011-11-29

    A grating pulse compressor configuration is introduced for increasing the optical dispersion for a given footprint and to make practical the application for chirped pulse amplification (CPA) to quasi-narrow bandwidth materials, such as Nd:YAG. The grating configurations often use cascaded pairs of gratings to increase angular dispersion an order of magnitude or more. Increased angular dispersion allows for decreased grating separation and a smaller compressor footprint.

  18. Characterizations of double pulsing in neutron multiplicity and coincidence counting systems

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, Katrina E., E-mail: kkoehler@lanl.gov [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States); Henzl, Vladimir [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States); Croft, Stephen S. [Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN 37831 (United States); Henzlova, Daniela; Santi, Peter A. [Los Alamos National Laboratory, P. O. Box 1663, Los Alamos, NM 87545 (United States)

    2016-10-01

    Passive neutron coincidence/multiplicity counters are subject to non-ideal behavior, such as double pulsing and dead time. It has been shown in the past that double-pulsing exhibits a distinct signature in a Rossi-alpha distribution, which is not readily noticed using traditional Multiplicity Shift Register analysis. However, it has been assumed that the use of a pre-delay in shift register analysis removes any effects of double pulsing. In this work, we use high-fidelity simulations accompanied by experimental measurements to study the effects of double pulsing on multiplicity rates. By exploiting the information from the double pulsing signature peak observable in the Rossi-alpha distribution, the double pulsing fraction can be determined. Algebraic correction factors for the multiplicity rates in terms of the double pulsing fraction have been developed. We discuss the role of these corrections across a range of scenarios.

  19. Harmonic generation with a dual frequency pulse.

    Science.gov (United States)

    Keravnou, Christina P; Averkiou, Michalakis A

    2014-05-01

    Nonlinear imaging was implemented in commercial ultrasound systems over the last 15 years offering major advantages in many clinical applications. In this work, pulsing schemes coupled with a dual frequency pulse are presented. The pulsing schemes considered were pulse inversion, power modulation, and power modulated pulse inversion. The pulse contains a fundamental frequency f and a specified amount of its second harmonic 2f. The advantages and limitations of this method were evaluated with both acoustic measurements of harmonic generation and theoretical simulations based on the KZK equation. The use of two frequencies in a pulse results in the generation of the sum and difference frequency components in addition to the other harmonic components. While with single frequency pulses, only power modulation and power modulated pulse inversion contained odd harmonic components, with the dual frequency pulse, pulse inversion now also contains odd harmonic components.

  20. Pulsed Corona for Sustainable Technology

    International Nuclear Information System (INIS)

    Heesch, E.J.M. van; Pemen, A.J.M.; Yan, K.; Blom, P.P.M.; Huijbrechts, P.A.H.J.; Der Laan, P.C.T. van

    2000-01-01

    Highly active coronas with a peak power of up to 25 MW p/m corona wire and kJ/liter energy densities in the streamer channels can be produced by pulsed power. Since the voltage pulses are short, full breakdown does not occur even though the discharge currents are hundreds of Amperes. A matched pulsed power source can deposit up to 80% of its electrical energy into such a controlled discharge. Reliable and efficient sources characterized by 100 kV,150 ns wide pulses at 1000 Hz have passed 400 hours of operation. The area of applications is growing: VOC control, hot gas cleanup, water and air purification and sterilization. (author)

  1. Next generation Chirped Pulse Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Nees, J; Biswal, S; Mourou, G [Univ. Michigan, Center for Ultrafast Optical Science, Ann Arbor, MI (United States); Nishimura, Akihiko; Takuma, Hiroshi

    1998-03-01

    The limiting factors of Chirped Pulse Amplification (CPA) are discussed and experimental results of CPA in Yb:glass regenerative amplifier are given. Scaling of Yb:glass to the petawatt level is briefly discussed. (author)

  2. Quantitative pulsed eddy current analysis

    International Nuclear Information System (INIS)

    Morris, R.A.

    1975-01-01

    The potential of pulsed eddy current testing for furnishing more information than conventional single-frequency eddy current methods has been known for some time. However, a fundamental problem has been analyzing the pulse shape with sufficient precision to produce accurate quantitative results. Accordingly, the primary goal of this investigation was to: demonstrate ways of digitizing the short pulses encountered in PEC testing, and to develop empirical analysis techniques that would predict some of the parameters (e.g., depth) of simple types of defect. This report describes a digitizing technique using a computer and either a conventional nuclear ADC or a fast transient analyzer; the computer software used to collect and analyze pulses; and some of the results obtained. (U.S.)

  3. Pulsed high-power beams

    International Nuclear Information System (INIS)

    Reginato, L.L.; Birx, D.L.

    1988-01-01

    The marriage of induction linac technology with nonlinear magnetic modulators has produced some unique capabilities. It is now possible to produce short-pulse electron beams with average currents measured in amperes, at gradients approaching 1-MeV/m, and with power efficiencies exceeding 50%. This paper reports on a 70-MeV, 3-kA induction accelerator (ETA II) constructed at the Lawrence Livermore National Laboratory that incorporates the pulse technology concepts that have evolved over the past several years. The ETA II is a linear induction accelerator and provides a test facility for demonstration of the high-average-power components and high-brightness sources used in such accelerators. The pulse drive of the accelerator is based on state-of-the-art magnetic pulse compressors with very high peak-power capability, repetition rates exceeding 1 kHz, and excellent reliability

  4. Current pulse shaping of the load current on PTS

    Directory of Open Access Journals (Sweden)

    Minghe Xia

    2016-02-01

    Full Text Available The typical rise time of PTS machine is ∼110 ns with about 10 MA peak current under short pulse mode when all 24 modules discharge simultaneously. By distributing the trigger times of 12 laser beams logically and adjusting the statues of the pulse output switches, longer rise-time pulse can be obtained on the PTS facility. Based on the required pulse shape, whole circuit simulations will be used to calculate the trigger times of each laser triggering gas switch and the status of the pulse output switches. The rise time of the current is determined by the time difference between the first and last trigged laser triggering gas switches. In order to trigger the laser triggering gas switch, sufficient laser power is needed to be sent into the gap of the gas switches. The gas pressure and voltage difference on the two electrodes of the gas switches also affect the triggering of the gas switches, and the voltage added on the gas switch is determined by its transition time. Traditionally the trigger time difference should be less than the transition time of the two neighboring modules. A new simulation model of PTS shows one can break this transition time limits. Series of current pulse shaping experiments have been investigated on the PTS (Primary Test Stand. As results, more than 5 MA peak current were successfully achieved on the load with a rise time of 600 ns. This study and experiments of the pulse shaping on PTS demonstrate the adaptable ability of the PTS for offering different waveform of mega ampere current pulse for different research purpose.

  5. An investigation of pulsed high density plasmas

    International Nuclear Information System (INIS)

    Timmermans, C.J.

    1984-01-01

    In this thesis a wall-stabilized argon cascade arc is studied at values of pulsed pressure up to 14 bar and a pulsed current range up to 2200 A with a time duration of about 2 ms. The basic plasma is a CW cascade arc with a 5 mm diameter plasma column and a length of 90 mm, which operates at a 60 A DC current and at one atmosphere filling pressure. The author starts with an extensive summary of the CW arc investigations. After a brief introduction of the basic transport equations the mass equations of the constituent particles are treated using the extended collisional radiative model. The energy balance equations and the momentum balance are discussed. The electron density is determined from measurements of the continuum radiation. The final chapter contains the experimental results on the electron temperatures and electron densities in the pressure and current pulsed plasma. Attention is given to the deviations from local thermodynamic equilibrium values of the ground level densities of the different argon systems. (Auth.)

  6. ANL experimental program for pulsed superconducting coils

    International Nuclear Information System (INIS)

    Wang, S.T.; Kim, S.H.; Praeg, W.F.; Krieger, C.I.

    1978-01-01

    Argonne National Laboratory (ANL) had recognized the clear advantage of a superconducting ohmic-heating (OH) coil and started in aggressive development program in FY 1977. The main objectives for FY 1977 are to develop cryostable basic cable configurations with reasonably low ac losses, to develop 12 kA cryostable cable, using it to design and build a 1.5 MJ pulsed coil, and to develop a rather inexpensive large fiberglass reinforced helium cryostat for the 1.5 MJ pulsed coil. The principal objective in building the 1.5 MJ ac coil is to demonstrate ac cryostability of a large coil ranging from 2 T/s up to 12 T/s. Another objective in the pulsed coil program is to determine the feasibility of parallel coil operation in order to avoid excessive voltage and current requirements and to minimize the number of turns for the equilibrium field (EF) coils, should the EF coils be connected in parallel with the OH coils. A two-coil section model using the 11 kA cable will be built and tested

  7. Evaluation of dynamic range for LLNL streak cameras using high contrast pulses and pulse podiatry'' on the Nova laser system

    Energy Technology Data Exchange (ETDEWEB)

    Richards, J.B.; Weiland, T.L.; Prior, J.A.

    1990-07-01

    A standard LLNL streak camera has been used to analyze high contrast pulses on the Nova laser facility. These pulses have a plateau at their leading edge (foot) with an amplitude which is approximately 1% of the maximum pulse height. Relying on other features of the pulses and on signal multiplexing, we were able to determine how accurately the foot amplitude was being represented by the camera. Results indicate that the useful single channel dynamic range of the instrument approaches 100:1. 1 ref., 4 figs., 1 tab.

  8. Pulsed ultrasonic stir welding system

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2013-01-01

    An ultrasonic stir welding system includes a welding head assembly having a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. During a welding operation, ultrasonic pulses are applied to the rod as it rotates about its longitudinal axis. The ultrasonic pulses are applied in such a way that they propagate parallel to the longitudinal axis of the rod.

  9. Pulsed feedback defers cellular differentiation.

    Directory of Open Access Journals (Sweden)

    Joe H Levine

    2012-01-01

    Full Text Available Environmental signals induce diverse cellular differentiation programs. In certain systems, cells defer differentiation for extended time periods after the signal appears, proliferating through multiple rounds of cell division before committing to a new fate. How can cells set a deferral time much longer than the cell cycle? Here we study Bacillus subtilis cells that respond to sudden nutrient limitation with multiple rounds of growth and division before differentiating into spores. A well-characterized genetic circuit controls the concentration and phosphorylation of the master regulator Spo0A, which rises to a critical concentration to initiate sporulation. However, it remains unclear how this circuit enables cells to defer sporulation for multiple cell cycles. Using quantitative time-lapse fluorescence microscopy of Spo0A dynamics in individual cells, we observed pulses of Spo0A phosphorylation at a characteristic cell cycle phase. Pulse amplitudes grew systematically and cell-autonomously over multiple cell cycles leading up to sporulation. This pulse growth required a key positive feedback loop involving the sporulation kinases, without which the deferral of sporulation became ultrasensitive to kinase expression. Thus, deferral is controlled by a pulsed positive feedback loop in which kinase expression is activated by pulses of Spo0A phosphorylation. This pulsed positive feedback architecture provides a more robust mechanism for setting deferral times than constitutive kinase expression. Finally, using mathematical modeling, we show how pulsing and time delays together enable "polyphasic" positive feedback, in which different parts of a feedback loop are active at different times. Polyphasic feedback can enable more accurate tuning of long deferral times. Together, these results suggest that Bacillus subtilis uses a pulsed positive feedback loop to implement a "timer" that operates over timescales much longer than a cell cycle.

  10. Artistic Representation with Pulsed Holography

    International Nuclear Information System (INIS)

    Ishii, S

    2013-01-01

    This thesis describes artistic representation through pulsed holography. One of the prevalent practical problems in making holograms is object movement. Any movement of the object or film, including movement caused by acoustic vibration, has the same fatal results. One way of reducing the chance of movement is by ensuring that the exposure is very quick; using a pulsed laser can fulfill this objective. The attractiveness of using pulsed laser is based on the variety of materials or objects that can be recorded (e.g., liquid material or instantaneous scene of a moving object). One of the most interesting points about pulsed holograms is that some reconstructed images present us with completely different views of the real world. For example, the holographic image of liquid material does not appear fluid; it looks like a piece of hard glass that would produce a sharp sound upon tapping. In everyday life, we are unfamiliar with such an instantaneous scene. On the other hand, soft-textured materials such as a feather or wool differ from liquids when observed through holography. Using a pulsed hologram, we can sense the soft touch of the object or material with the help of realistic three-dimensional (3-D) images. The images allow us to realize the sense of touch in a way that resembles touching real objects. I had the opportunity to use a pulsed ruby laser soon after I started to work in the field of holography in 1979. Since then, I have made pulsed holograms of activities, including pouring water, breaking eggs, blowing soap bubbles, and scattering feathers and popcorn. I have also created holographic art with materials and objects, such as silk fiber, fabric, balloons, glass, flowers, and even the human body. Whenever I create art, I like to present the spectator with a new experience in perception. Therefore, I would like to introduce my experimental artwork through those pulsed holograms.

  11. Initial Breakdown Pulse Amplitudes in Intracloud and Cloud-to-Ground Lightning Flashes

    Science.gov (United States)

    Marshall, T. C.; Smith, E. M.; Stolzenburg, M.; Karunarathne, S.; Siedlecki, R. D., II

    2017-12-01

    This study analyzes the largest initial breakdown (IB) pulse in flashes from three storms in Florida. The study was motivated in part by the possibility that IB pulses of IC flashes may cause of terrestrial gamma-ray flashes (TGFs). The range-normalized, zero-to-peak amplitude of the largest IB pulse within each flash was determined along with its altitude, duration, and occurrence time in the flash. Appropriate data were available for 40 intracloud (IC) and 32 cloud-to-ground (CG) flashes. Histograms of the magnitude of the largest IB pulse amplitude by flash type were similar, with mean (median) values of 1.49 (1.05) V/m for IC flashes and -1.35 (-0.87) V/m for CG flashes. The mean amplitude of the largest IC IB pulses are substantially smaller (roughly an order of magnitude smaller) than the few known pulse amplitudes of TGF events and TGF candidate events. The largest IB pulse in 30 IC flashes showed a weak inverse relation between pulse amplitude and altitude. Amplitude of the largest IB pulse for 25 CG flashes showed no altitude correlation. Duration of the largest IB pulse in ICs averaged twice as long as in CGs (96 μs versus 46 μs); all of the CG durations were <100 μs. Among the ICs, there is a positive relation between largest IB pulse duration and amplitude; the linear correlation coefficient is 0.385 with outliers excluded. The largest IB pulse in IC flashes typically occurred at a longer time after the first IB pulse (average 4.1 ms) than was the case in CG flashes (average 0.6 ms). In both flash types, the largest IB pulse was the first IB pulse in about 30% of the cases.

  12. The Toulouse pulsed magnet facility

    International Nuclear Information System (INIS)

    2006-01-01

    The 'Laboratoire National des Champs Magnetiques Pulses' (LNCMP) is an international user facility providing access to pulsed magnetic fields up to and beyond 60 T. The laboratory disposes of 10 magnet stations equipped with long-pulse magnets operating in the 35-60 T range and a short-pulse system reaching magnetic fields in excess of 70 T. The experimental infrastructure includes various high and low-temperature systems ranging from ordinary flow-type cryostats to dilution refrigerators reaching 50 mK, as well as different types of high-pressure cells. Experimental techniques include magnetization, transport, luminescence, IR-spectroscopy and polarimetry. The LNCMP pursues an extensive in-house research program focussing on all technological and scientific aspects of pulsed magnetic fields. Recent technical developments include the implementation of 60 T rapid-cooling coils, an 80 T prototype, a pulsed dipole magnet for optical investigations of dilute matter and a transportable horizontal access magnet for small angle x-ray scattering experiments. Scientific activities cover a variety of domains, including correlated electron systems, magnetism, semiconductors and nanoscience

  13. Pulsed power accelerator for material physics experiments

    Directory of Open Access Journals (Sweden)

    D. B. Reisman

    2015-09-01

    Full Text Available We have developed the design of Thor: a pulsed power accelerator that delivers a precisely shaped current pulse with a peak value as high as 7 MA to a strip-line load. The peak magnetic pressure achieved within a 1-cm-wide load is as high as 100 GPa. Thor is powered by as many as 288 decoupled and transit-time isolated bricks. Each brick consists of a single switch and two capacitors connected electrically in series. The bricks can be individually triggered to achieve a high degree of current pulse tailoring. Because the accelerator is impedance matched throughout, capacitor energy is delivered to the strip-line load with an efficiency as high as 50%. We used an iterative finite element method (FEM, circuit, and magnetohydrodynamic simulations to develop an optimized accelerator design. When powered by 96 bricks, Thor delivers as much as 4.1 MA to a load, and achieves peak magnetic pressures as high as 65 GPa. When powered by 288 bricks, Thor delivers as much as 6.9 MA to a load, and achieves magnetic pressures as high as 170 GPa. We have developed an algebraic calculational procedure that uses the single brick basis function to determine the brick-triggering sequence necessary to generate a highly tailored current pulse time history for shockless loading of samples. Thor will drive a wide variety of magnetically driven shockless ramp compression, shockless flyer plate, shock-ramp, equation of state, material strength, phase transition, and other advanced material physics experiments.

  14. A hybrid pulse combining topology utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer.

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Sun, Yi; Liu, Yuhao; Ren, Ziyuan; He, Jiaxin; Cao, Hui; Zheng, Minjun

    2017-03-01

    Numerous applications driven by pulsed voltage require pulses to be with high amplitude, high repetitive frequency, and narrow width, which could be satisfied by utilizing avalanche transistors. The output improvement is severely limited by power capacities of transistors. Pulse combining is an effective approach to increase the output amplitude while still adopting conventional pulse generating modules. However, there are drawbacks in traditional topologies including the saturation tendency of combining efficiency and waveform oscillation. In this paper, a hybrid pulse combining topology was adopted utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer. The factors affecting the combining efficiency were determined including the output time synchronization of Marx circuits, and the quantity and position of magnetic cores. The numbers of the parallel modules and the stages were determined by the output characteristics of each combining method. Experimental results illustrated the ability of generating pulses with 2-14 kV amplitude, 7-11 ns width, and a maximum 10 kHz repetitive rate on a matched 50-300 Ω resistive load. The hybrid topology would be a convinced pulse combining method for similar nanosecond pulse generators based on the solid-state switches.

  15. Simultaneous multi-element analysis of some edible pulses using neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, F.H.; Metwally, E.; Abdel-Khalik, H.

    2007-01-01

    This paper comprises the application of instrumental neutron activation analysis (INAA) for multi-element determination in some edible pulse samples. These edible pulses are usually daily used in the Egyptian kitchen. These were: anise, cumin, coriander, caraway, black cumin, white kidney bean, lupine, lentil, chickpea, broad bean, peanut, almond, and fenugreek. The pulses have been analyzed as dehulled pulses, in the case of legume and oil pulses with simultaneous analysis of their respective skins. The determined elements were: Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Th and Zn. The element content in the dehulled pulses and their respective skins has been compared. Some elements were major or minor elements where others were trace elements. Standard reference materials were used to assure quality control, accuracy and precision of the technique. (author)

  16. Pulse Shape Tuning in Neutrino Detector Scintillator Systems

    Energy Technology Data Exchange (ETDEWEB)

    Aberle, Ch.; Buck, Ch.; Hartmann, F.X.; Schoenert, St. [Max Planck Institute for Nuclear Physics, Heidelberg (Germany); Hartmann, F.X. [Hartmann Scientific, City of Virginia Beach, Virginia (United States)

    2009-07-01

    Full text of publication follows: A new light yield model based on energy transfer pathways in codoped organic liquid scintillator systems is created and used to determine experimentally non-radiative energy transfer rate constants from which time dependent light pulse shapes and total light yields are predicted for multi-component liquids. Such constants determine effective Forster-Dexter critical concentrations. A surprising discovery regarding the critical concentration in n-dodecane permits tuning the pulse shape for different regions in the Double Chooz neutrino detector. (authors)

  17. Square pulse linear transformer driver

    Directory of Open Access Journals (Sweden)

    A. A. Kim

    2012-04-01

    Full Text Available The linear transformer driver (LTD technological approach can result in relatively compact devices that can deliver fast, high current, and high-voltage pulses straight out of the LTD cavity without any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The usual LTD architecture [A. A. Kim, M. G. Mazarakis, V. A. Sinebryukhov, B. M. Kovalchuk, V. A. Vizir, S. N Volkov, F. Bayol, A. N. Bastrikov, V. G. Durakov, S. V. Frolov, V. M. Alexeenko, D. H. McDaniel, W. E. Fowler, K. LeCheen, C. Olson, W. A. Stygar, K. W. Struve, J. Porter, and R. M. Gilgenbach, Phys. Rev. ST Accel. Beams 12, 050402 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050402; M. G. Mazarakis, W. E. Fowler, A. A. Kim, V. A. Sinebryukhov, S. T. Rogowski, R. A. Sharpe, D. H. McDaniel, C. L. Olson, J. L. Porter, K. W. Struve, W. A. Stygar, and J. R. Woodworth, Phys. Rev. ST Accel. Beams 12, 050401 (2009PRABFM1098-440210.1103/PhysRevSTAB.12.050401] provides sine shaped output pulses that may not be well suited for some applications like z-pinch drivers, flash radiography, high power microwaves, etc. A more suitable power pulse would have a flat or trapezoidal (rising or falling top. In this paper, we present the design and first test results of an LTD cavity that generates such a type of output pulse by including within its circular array a number of third harmonic bricks in addition to the main bricks. A voltage adder made out of a square pulse cavity linear array will produce the same shape output pulses provided that the timing of each cavity is synchronized with the propagation of the electromagnetic pulse.

  18. Long Silver Nanowires Synthesis by Pulsed Electrodeposition

    Directory of Open Access Journals (Sweden)

    M.R. Batevandi

    2015-09-01

    Full Text Available Silver nanowires were pulse electrodeposited into nanopore anodic alumina oxide templates. The effects of continuous and pulse electrodeposition waveform on the microstructure properties of the nanowire arrays were studied. It is seen that the microstructure of nanowire is depend to pulse condition. The off time duration of pulse waveform enables to control the growth direction of Ag nanowires.

  19. System for increasing laser pulse rate

    International Nuclear Information System (INIS)

    1980-01-01

    A technique of static elements is disclosed for combining a plurality of laser beams having time sequenced, pulsed radiation to achieve an augmented pulse rate. The technique may also be applied in a system for combining both time sequenced pulses and frequency distinct pulses for use in a system for isotope enrichment. (author)

  20. Neutron induced current pulses in fission chambers

    International Nuclear Information System (INIS)

    Taboas, A.L.; Buck, W.L.

    1978-01-01

    The mechanism of neutron induced current pulse generation in fission chambers is discussed. By application of the calculated detector transfer function to proposed detector current pulse shapes, and by comparison with actually observed detector output voltage pulses, a credible, semi-empirical, trapezoidal pulse shape of chamber current is obtained

  1. Pulse frequency in pulsed brachytherapy based on tissue repair kinetics

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Koedooder, Kees; Tienhoven, Geertjan van; Blank, Leo E.C.M.; Gonzalez Gonzalez, Dionisio

    1998-01-01

    Purpose: Investigation of normal tissue sparing in pulsed brachytherapy (PB) relative to continuous low-dose rate irradiation (CLDR) by adjusting pulse frequency based on tissue repair characteristics. Method: Using the linear quadratic model, the relative effectiveness (RE) of a 20 Gy boost was calculated for tissue with an α/β ratio ranging from 2 to 10 Gy and a half-time of sublethal damage repair between 0.1 and 3 h. The boost dose was considered to be delivered either in a number of pulses varying from 2 to 25, or continuously at a dose rate of 0.50, 0.80, or 1.20 Gy/h. Results: The RE of 20 Gy was found to be identical for PB in 25 pulses of 0.80 Gy each h and CLDR delivered at 0.80 Gy/h for any α/β value and for a repair half-time > 0.75 h. When normal tissue repair half-times are assumed to be longer than tumor repair half-times, normal tissue sparing can be obtained, within the restriction of a fixed overall treatment time, with higher dose per pulse and longer period time (time elapsed between start of pulse n and start of pulse n + 1). An optimum relative normal tissue sparing larger than 10% was found with 4 pulses of 5 Gy every 8 h. Hence, a therapeutic gain might be obtained when changing from CLDR to PB by adjusting the physical dose in such a way that the biological dose on the tumor is maintained. The normal tissue-sparing phenomenon can be explained by an increase in RE with longer period time for tissue with high α/β ratio and fast or intermediate repair half-time, and the RE for tissue with low α/β ratio and long repair half-time remains almost constant. Conclusion: Within the benchmark of the LQ model, advantage in normal tissue-sparing is expected when matching the pulse frequency to the repair kinetics of the normal tissue exposed. A period time longer than 1 h may lead to a reduction of late normal tissue complications. This theoretical advantage emphasizes the need for better knowledge of human tissue-repair kinetics

  2. Method for measuring the stochastic properties of corona and partial-discharge pulses

    International Nuclear Information System (INIS)

    Van Brunt, R.J.; Kulkarni, S.V.

    1989-01-01

    A new method is described for measuring the stochastic behavior of corona and partial-discharge pulses which utilizes a pulse selection and sorting circuit in conjunction with a computer-controlled multichannel analyzer to directly measure various conditional and unconditional pulse-height and pulse-time-separation distributions. From these measured distributions it is possible to determine the degree of correlation between successive discharge pulses. Examples are given of results obtained from measurements on negative, point-to-plane (Trichel-type) corona pulses in a N 2 /O 2 gas mixture which clearly demonstrate that the phenomenon is inherently stochastic in the sense that development of a discharge pulse is significantly affected by the amplitude of and time separation from the preceding pulse. It is found, for example, that corona discharge pulse amplitude and time separation from an earlier pulse are not independent random variables. Discussions are given about the limitations of the method, sources of error, and data analysis procedures required to determine self-consistency of the various measured distributions

  3. Design considerations for epithermal pulse reactors

    International Nuclear Information System (INIS)

    Ostensen, R.W.

    1978-01-01

    Simplified design criteria were developed for scoping analyses of epithermal pulse reactors for use in LMFBR safety testing. By using these criteria, materials and designs were investigated to determine performance limits of moderately sized reactor cores. Several designs are suggested for further study. These are a gas-cooled core fueled with a heterogeneous mixture of Fe-UO 2 cermet and BeO-UO 2 ceramic fuels, and a heavy-water-cooled core fueled with an Fe-UO 2 cermet

  4. Electric fields in plasmas under pulsed currents

    International Nuclear Information System (INIS)

    Tsigutkin, K.; Doron, R.; Stambulchik, E.; Bernshtam, V.; Maron, Y.; Fruchtman, A.; Commisso, R. J.

    2007-01-01

    Electric fields in a plasma that conducts a high-current pulse are measured as a function of time and space. The experiment is performed using a coaxial configuration, in which a current rising to 160 kA in 100 ns is conducted through a plasma that prefills the region between two coaxial electrodes. The electric field is determined using laser spectroscopy and line-shape analysis. Plasma doping allows for three-dimensional spatially resolved measurements. The measured peak magnitude and propagation velocity of the electric field is found to match those of the Hall electric field, inferred from the magnetic-field front propagation measured previously

  5. River water remediation using pulsed corona, pulsed spark or ozonation

    Energy Technology Data Exchange (ETDEWEB)

    Izdebski, T.; Dors, M. [Polish Academy of Sciences, Szewalski Inst. of Fluid Flow Machiney, Fiszera (Poland). Centre for Plasma and Laser Engineering; Mizeraczyk, J. [Polish Academy of Sciences, Szewalski Inst. of Fluid Flow Machiney, Fiszera (Poland). Centre for Plasma and Laser Engineering; Gdynia Maritime Univ., Morska (Poland). Dept. of Marine Electronics

    2010-07-01

    The most common reason for epidemic formation is the pollution of surface and drinking water by wastewater bacteria. Pathogenic microorganisms that form the largest part of this are fecal bacteria, such as escherichia coli (E. coli). Wastewater treatment plants reduce the amount of the fecal bacteria by 1-3 orders of magnitude, depending on the initial number of bacteria. There is a lack of data on waste and drinking water purification by the electrohydraulic discharges method, which causes the destruction and inactivation of viruses, yeast, and bacteria. This paper investigated river water cleaning from microorganisms using pulsed corona, spark discharge and ozonization. The paper discussed the experimental setup and results. It was concluded that ozonization is the most efficient method of water disinfection as compared with pulsed spark and pulsed corona discharges. The pulsed spark discharge in water was capable of killing all microorganism similarly to ozonization, but with much lower energy efficiency. The pulsed corona discharge was found to be the less effective method of water disinfection. 21 refs., 4 figs.

  6. Industrial Applications of Pulsed Power Technology

    Science.gov (United States)

    Takaki, Koichi; Katsuki, Sunao

    Recent progress of the industrial applications of pulsed power is reviewed in this paper. Repetitively operated pulsed power generators with a moderate peak power have been developed for industrial applications. These generators are reliable and low maintenance. Development of the pulsed power generators helps promote industrial applications of pulsed power for such things as food processing, medical treatment, water treatment, exhaust gas treatment, ozone generation, engine ignition, ion implantation and others. Here, industrial applications of pulsed power are classified by application for biological effects, for pulsed streamer discharges in gases, for pulsed discharges in liquid or liquid-mixture, and for bright radiation sources.

  7. Proposta de roteiro para a determinação das variáveis de soldagem do Processo TIG pulsado aplicado à soldagem de chapas finas Proposal of roadmap for determining the variables of pulsed TIG welding process applied to welding of thin plates

    Directory of Open Access Journals (Sweden)

    Tiago Vieira da Cunha

    2013-03-01

    Full Text Available Na soldagem TIG pulsada a corrente varia entre dois níveis bem definidos de energia numa determinada frequência, sendo, portanto, necessário a regulagem de um conjunto de variáveis composto pela corrente de pulso, tempo de pulso, corrente de base, tempo de base, além da velocidade de soldagem. Entretanto, apesar de ser uma técnica tão amplamente difundida, na prática estas variáveis de soldagem muitas vezes são reguladas de forma arbitrária. Isto pode conduzir ao uso ineficiente da pulsação da corrente quando considerado o resultado final da solda, bem como nos aspectos de produtividade. Diante desta carência, este trabalho tem por objetivo apresentar um roteiro desenvolvido com o intuito de suprir a necessidade prática de se estabelecer critérios para auxiliar a determinação das variáveis da soldagem TIG pulsada, tomando como premissa a largura desejada para o cordão de solda final, a sobreposição entre os pontos de solda que compõem o cordão e a velocidade de soldagem. Por fim, é apresentada uma aplicação deste roteiro na soldagem "bead on plate" de chapas de aço inox com 1,2 mm de espessura.In pulsed TIG welding the current varies between two well-defined energy levels in a given frequency being, therefore, necessary to the adjustment of a set of variables consisting of the peak current, peak time, background current, background time and the welding speed. However, despite being a technique so widespread, in practice these welding variables are often regulated arbitrarily. This can lead to inefficient use of the pulsed current regarding the end result of the weld as well as in the aspects of productivity. Given this shortage, this paper aims to present a roadmap developed in order to meet the practical need to establish criteria to assist in the determination of pulsed TIG welding variables, taking as its premise the desired width of the weld bead, overlap between the weld points comprising the weld bead and the

  8. Vacuum deposition and pulsed modification of Ge thin films on Si. Structure and photoluminescence

    International Nuclear Information System (INIS)

    Batalov, R.I.; Bayazitov, R.M.; Novikov, G.A.; Shustov, V.A.; Bizyaev, D.A.; Gajduk, P.I.; Ivlev, G.D.; Prokop'ev, S.L.

    2013-01-01

    Vacuum deposition of Ge thin films onto Si substrates by magnetron sputtering was studied. During deposition sputtering time and substrate temperature were varied. Nanosecond pulsed annealing of deposited films by powerful laser or ion beams was performed. The dependence of the structure and optical properties of Ge/Si films on parameters of pulsed treatments was investigated. Optimum parameters of deposition and pulsed treatments resulting into light emitting monocrystalline Ge/Si layers are determined. (authors)

  9. Transient thermal analysis of semiconductor diode lasers under pulsed operation

    Science.gov (United States)

    Veerabathran, G. K.; Sprengel, S.; Karl, S.; Andrejew, A.; Schmeiduch, H.; Amann, M.-C.

    2017-02-01

    Self-heating in semiconductor lasers is often assumed negligible during pulsed operation, provided the pulses are `short'. However, there is no consensus on the upper limit of pulse width for a given device to avoid-self heating. In this paper, we present an experimental and theoretical analysis of the effect of pulse width on laser characteristics. First, a measurement method is introduced to study thermal transients of edge-emitting lasers during pulsed operation. This method can also be applied to lasers that do not operate in continuous-wave mode. Secondly, an analytical thermal model is presented which is used to fit the experimental data to extract important parameters for thermal analysis. Although commercial numerical tools are available for such transient analyses, this model is more suitable for parameter extraction due to its analytical nature. Thirdly, to validate this approach, it was used to study a GaSb-based inter-band laser and an InP-based quantum cascade laser (QCL). The maximum pulse-width for less than 5% error in the measured threshold currents was determined to be 200 and 25 ns for the GaSb-based laser and QCL, respectively.

  10. Perspectives of shaped pulses for EPR spectroscopy

    Science.gov (United States)

    Spindler, Philipp E.; Schöps, Philipp; Kallies, Wolfgang; Glaser, Steffen J.; Prisner, Thomas F.

    2017-07-01

    This article describes current uses of shaped pulses, generated by an arbitrary waveform generator, in the field of EPR spectroscopy. We show applications of sech/tanh and WURST pulses to dipolar spectroscopy, including new pulse schemes and procedures, and discuss the more general concept of optimum-control-based pulses for applications in EPR spectroscopy. The article also describes a procedure to correct for experimental imperfections, mostly introduced by the microwave resonator, and discusses further potential applications and limitations of such pulses.

  11. Pulsed Corona Discharge Generated By Marx Generator

    Science.gov (United States)

    Sretenovic, G. B.; Obradovic, B. M.; Kovacevic, V. V.; Kuraica, M. M.; Puric J.

    2010-07-01

    The pulsed plasma has a significant role in new environmental protection technologies. As a part of a pulsed corona system for pollution control applications, Marx type repetitive pulse generator was constructed and tested in arrangement with wire-plate corona reactor. We performed electrical measurements, and obtained voltage and current signals, and also power and energy delivered per pulse. Ozone formation by streamer plasma in air was chosen to monitor chemical activity of the pulsed corona discharge.

  12. Effect of sequential isoproturon pulse exposure on Scenedesmus vacuolatus.

    Science.gov (United States)

    Vallotton, Nathalie; Eggen, Rik Ilda Lambertus; Chèvre, Nathalie

    2009-04-01

    Aquatic organisms are typically exposed to fluctuating concentrations of herbicides in streams. To assess the effects on algae of repeated peak exposure to the herbicide isoproturon, we subjected the alga Scenedesmus vacuolatus to two sequential pulse exposure scenarios. Effects on growth and on the inhibition of the effective quantum yield of photosystem II (PSII) were measured. In the first scenario, algae were exposed to short, 5-h pulses at high isoproturon concentrations (400 and 1000 microg/l), each followed by a recovery period of 18 h, while the second scenario consisted of 22.5-h pulses at lower concentrations (60 and 120 microg/l), alternating with short recovery periods (1.5 h). In addition, any changes in the sensitivity of the algae to isoproturon following sequential pulses were examined by determining the growth rate-EC(50) prior to and following exposure. In both exposure scenarios, we found that algal growth and its effective quantum yield were systematically inhibited during the exposures and that these effects were reversible. Sequential pulses to isoproturon could be considered a sequence of independent events. Nevertheless, a consequence of inhibited growth during the repeated exposures is the cumulative decrease in biomass production. Furthermore, in the second scenario, when the sequence of long pulses began to approach a scenario of continuous exposure, a slight increase in the tolerance of the algae to isoproturon was observed. These findings indicated that sequential pulses do affect algae during each pulse exposure, even if algae recover between the exposures. These observations could support an improved risk assessment of fluctuating exposures to reversibly acting herbicides.

  13. Response of larval sea lampreys (Petromyzon marinus) to pulsed DC electrical stimuli in laboratory experiments

    Science.gov (United States)

    Bowen, Anjanette K.; Weisser, John W.; Bergstedt, Roger A.; Famoye, Felix

    2003-01-01

    Four electrical factors that are used in pulsed DC electrofishing for larval sea lampreys (Petromyzon marinus) were evaluated in two laboratory studies to determine the optimal values to induce larval emergence over a range of water temperatures and conductivities. Burrowed larvae were exposed to combinations of pulsed DC electrical factors including five pulse frequencies, three pulse patterns, and two levels of duty cycle over a range of seven voltage gradients in two separate studies conducted at water temperatures of 10, 15, and 20°C and water conductivities of 25, 200, and 900 μS/cm. A four-way analysis of variance was used to determine significant (α = 0.05) influences of each electrical factor on larval emergence. Multiple comparison tests with Bonferroni adjustments were used to determine which values of each factor resulted in significantly higher emergence at each temperature and conductivity. Voltage gradient and pulse frequency significantly affected emergence according to the ANOVA model at each temperature and conductivity tested. Duty cycle and pulse pattern generally did not significantly influence the model. Findings suggest that a setting of 2.0 V/cm, 3 pulses/sec, 10% duty, and 2:2 pulse pattern seems the most promising in waters of medium conductivity and across a variety of temperatures. This information provides a basis for understanding larval response to pulsed DC electrofishing gear factors and identifies electrofisher settings that show promise to increase the efficiency of the gear during assessments for burrowed sea lamprey larvae.

  14. Study of pulse shapes in Ge detectors with PET

    Energy Technology Data Exchange (ETDEWEB)

    Grabmayr, Peter; Hegai, Alexander; Jochum, Josef; Schmitt, Christopher; Schuetz, Ann-Kathrin [Eberhard Karls Univeritaet Tuebingen (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    The Gerda collaboration aims to determine the half life of the neutrinoless double beta decay (0νββ) of {sup 76}Ge. For Phase II Gerda wants to reduce the background contribution significantly by active background-suppression techniques. One of such techniques is the pulse shape analysis of signals induced by the interaction of radiation with the detector. The pulse shapes depend not only on the energy of the interacting gamma, the geometry and field configuration but also on the location of interaction in the crystal. The waveform and the location of the interaction in the germanium can be determined by positron-emission-tomography (PET). First results of this novel pulse shape study with the PET will be presented in this talk.

  15. Forensic applications of {sup 14}C bomb-pulse dating

    Energy Technology Data Exchange (ETDEWEB)

    Zoppi, U. E-mail: ugo@ansto.gov.au; Skopec, Z.; Skopec, J.; Jones, G.; Fink, D.; Hua, Q.; Jacobsen, G.; Tuniz, C.; Williams, A

    2004-08-01

    After a brief review of the basics of {sup 14}C bomb-pulse dating, this paper presents two unique forensic applications. Particular attention is dedicated to the use of the {sup 14}C bomb-pulse to establish the time of harvest of illicit drugs such as heroin and opium. Preliminary measurements of {sup 14}C concentrations in milligram samples taken from seized drugs are presented. {sup 14}C bomb-pulse dating can determine whether drug distribution originates from stockpiles or recent manufacture, and support the action of law enforcement authorities against criminal organisations involved in drug trafficking. In addition, we describe the dating of wine vintages for a number of authenticated single label vintage red wines from the Barossa Valley - South Australia. Our results show that radiocarbon dating can be used to accurately determine wine vintages and therefore reveal the addition of unrelated materials of natural and synthetic origin.

  16. Forensic applications of 14C bomb-pulse dating

    International Nuclear Information System (INIS)

    Zoppi, U.; Skopec, Z.; Skopec, J.; Jones, G.; Fink, D.; Hua, Q.; Jacobsen, G.; Tuniz, C.; Williams, A.

    2004-01-01

    After a brief review of the basics of 14 C bomb-pulse dating, this paper presents two unique forensic applications. Particular attention is dedicated to the use of the 14 C bomb-pulse to establish the time of harvest of illicit drugs such as heroin and opium. Preliminary measurements of 14 C concentrations in milligram samples taken from seized drugs are presented. 14 C bomb-pulse dating can determine whether drug distribution originates from stockpiles or recent manufacture, and support the action of law enforcement authorities against criminal organisations involved in drug trafficking. In addition, we describe the dating of wine vintages for a number of authenticated single label vintage red wines from the Barossa Valley - South Australia. Our results show that radiocarbon dating can be used to accurately determine wine vintages and therefore reveal the addition of unrelated materials of natural and synthetic origin

  17. Forensic applications of 14C bomb-pulse dating

    Science.gov (United States)

    Zoppi, U.; Skopec, Z.; Skopec, J.; Jones, G.; Fink, D.; Hua, Q.; Jacobsen, G.; Tuniz, C.; Williams, A.

    2004-08-01

    After a brief review of the basics of 14C bomb-pulse dating, this paper presents two unique forensic applications. Particular attention is dedicated to the use of the 14C bomb-pulse to establish the time of harvest of illicit drugs such as heroin and opium. Preliminary measurements of 14C concentrations in milligram samples taken from seized drugs are presented. 14C bomb-pulse dating can determine whether drug distribution originates from stockpiles or recent manufacture, and support the action of law enforcement authorities against criminal organisations involved in drug trafficking. In addition, we describe the dating of wine vintages for a number of authenticated single label vintage red wines from the Barossa Valley - South Australia. Our results show that radiocarbon dating can be used to accurately determine wine vintages and therefore reveal the addition of unrelated materials of natural and synthetic origin.

  18. Pulse carboxyhemoglobin-oximetry and cigarette smoking.

    Science.gov (United States)

    Sokolova-Djokić, L; Milosević, S; Skrbić, R; Salabat, R; Voronov, G; Igić, R

    2011-01-01

    We used a pulse carbon monoxide (CO)-oximeter to measure the levels of carboxyhemoglobin (COHb) in smokers and non-smokers. Our goal was to determine if this device could not only define smoking status, but also to increase accuracy of self-reported data at various surveys on smoking. Thirty-four healthy volunteers participated in this study. Twenty-two of them were current daily smokers; 12 participants were non-smokers who lived alone or with a nonsmoker, and who worked in non-smoking environment. Nicotine dependency level was determined by the modified Fagerstrom questionnaire. Blood COHb levels were measured with a pulse CO-oximeter (Masimo, Radical 7). The COHb levels in both moderate/heavy smokers and light smokers increased significantly after they smoked a single cigarette. This increase persisted for more than 6 h in the moderate/heavy smokers, while in the light smokers COHb levels returned to the baseline level after one hour. The pulse rate of all smokers increased significantly 20 min after smoking. We conclude that the CO-oximeter can detect smoking by moderate/heavy smokers and light smokers if they smoked 6 h or 20 min earlier, respectively. We concluded that it could be used as a validation test for smoking at the time of admission to the surgical facility and to increase smoking abstinence during preoperative and postoperative periods. This noninvasive, simple and inexpensive test may also be used at various surveys to increase accuracy of self-reports on smoking.

  19. Influence of laser pulse frequency on the microstructure of aluminum nitride thin films synthesized by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Antonova, K., E-mail: krasa@issp.bas.bg [Institute of Solid State Physics, Bulgarian Academy of Sciences, Tzarigradsko Chaussee 72, Sofia 1784 (Bulgaria); Duta, L. [National Institute for Lasers, Plasma, and Radiation Physics, 409 Atomistilor Street, 077125 Magurele (Romania); Szekeres, A. [Institute of Solid State Physics, Bulgarian Academy of Sciences, Tzarigradsko Chaussee 72, Sofia 1784 (Bulgaria); Stan, G.E. [National Institute of Materials Physics, 105 bis Atomistilor Street, 077125 Magurele (Romania); Mihailescu, I.N. [National Institute for Lasers, Plasma, and Radiation Physics, 409 Atomistilor Street, 077125 Magurele (Romania); Anastasescu, M.; Stroescu, H.; Gartner, M. [Institute of Physical Chemistry, “Ilie Murgulescu”, Romanian Academy, 202 Splaiul Independentei, 060021 Bucharest (Romania)

    2017-02-01

    Highlights: • Study of pulsed laser deposited AlN films at different laser pulse frequencies. • Higher laser pulse frequency promotes nanocrystallites formation at temperature 450 °C. • AFM and GIXRD detect randomly oriented wurtzite AlN structures. • Characterization of the nanocrystallites’ orientation by FTIR reflectance spectra. • Berreman effect is registered in p-polarised radiation at large incidence angles. - Abstract: Aluminum Nitride (AlN) thin films were synthesized on Si (100) wafers at 450 °C by pulsed laser deposition. A polycrystalline AlN target was multipulsed irradiated in a nitrogen ambient, at different laser pulse repetition rate. Grazing Incidence X-Ray Diffraction and Atomic Force Microscopy analyses evidenced nanocrystallites with a hexagonal lattice in the amorphous AlN matrix. The thickness and optical constants of the layers were determined by infrared spectroscopic ellipsometry. The optical properties were studied by Fourier Transform Infrared reflectance spectroscopy in polarised oblique incidence radiation. Berreman effect was observed around the longitudinal phonon modes of the crystalline AlN component. Angular dependence of the A{sub 1}LO mode frequency was analysed and connected to the orientation of the particles’ optical axis to the substrate surface normal. The role of the laser pulse frequency on the layers’ properties is discussed on this basis.

  20. Pulsed neutron sources at Dubna

    International Nuclear Information System (INIS)

    Shabalin, E.P.

    1991-01-01

    In 1960 the first world repetitively pulsed reactor IBR was put into operation. It was the beginning of the story how fission based pulsed neutron sources at Dubna have survived. The engineers involved have experienced many successes and failures in the course of new sources upgrading to finally come to possess the world's brightest neutron source - IBR-2. The details are being reviewed through the paper. The fission based pulsed neutron sources did not reach their final state as yet- the conceptual views of IBR prospects are being discussed with the goal to double the thermal neutron peak flux (up to 2x10 16 ) and to enhance the cold neutron flux by 10 times (with the present one being as high that of the ISIS cold moderator). (author)