  1. Cardiac output by pulse contour analysis does not match the increase measured by rebreathing during human spaceflight.

    Science.gov (United States)

    Hughson, Richard L; Peterson, Sean D; Yee, Nicholas J; Greaves, Danielle K

    2017-11-01

    Pulse contour analysis of the noninvasive finger arterial pressure waveform provides a convenient means to estimate cardiac output (Q̇). The method has been compared with standard methods under a range of conditions but never before during spaceflight. We compared pulse contour analysis with the Modelflow algorithm to estimates of Q̇ obtained by rebreathing during preflight baseline testing and during the final month of long-duration spaceflight in nine healthy male astronauts. By Modelflow analysis, stroke volume was greater in supine baseline than seated baseline or inflight. Heart rate was reduced in supine baseline so that there were no differences in Q̇ by Modelflow estimate between the supine (7.02 ± 1.31 l/min, means ± SD), seated (6.60 ± 1.95 l/min), or inflight (5.91 ± 1.15 l/min) conditions. In contrast, rebreathing estimates of Q̇ increased from seated baseline (4.76 ± 0.67 l/min) to inflight (7.00 ± 1.39 l/min, significant interaction effect of method and spaceflight, P < 0.001). Pulse contour analysis utilizes a three-element Windkessel model that incorporates parameters dependent on aortic pressure-area relationships that are assumed to represent the entire circulation. We propose that a large increase in vascular compliance in the splanchnic circulation invalidates the model under conditions of spaceflight. Future spaceflight research measuring cardiac function needs to consider this important limitation for assessing absolute values of Q̇ and stroke volume. NEW & NOTEWORTHY Noninvasive assessment of cardiac function during human spaceflight is an important tool to monitor astronaut health. This study demonstrated that pulse contour analysis of finger arterial blood pressure to estimate cardiac output failed to track the 46% increase measured by a rebreathing method. These results strongly suggest that alternative methods not dependent on pulse contour analysis are required to track cardiac function in spaceflight

  2. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution

    Directory of Open Access Journals (Sweden)

    Ole Broch

    2016-01-01

    Full Text Available Objective. Today, there exist several different pulse contour algorithms for calculation of cardiac output (CO. The aim of the present study was to compare the accuracy of nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB. Methods. Thirty patients scheduled for elective coronary surgery were studied before and after CPB. A passive leg raising maneuver was also performed. Measurements included CO obtained by transpulmonary thermodilution (COTPTD and by nine pulse contour algorithms (COX1–9. Calibration of pulse contour algorithms was performed by esophageal Doppler ultrasound after induction of anesthesia and 15 min after CPB. Correlations, Bland-Altman analysis, four-quadrant, and polar analysis were also calculated. Results. There was only a poor correlation between COTPTD and COX1–9 during passive leg raising and in the period before and after CPB. Percentage error exceeded the required 30% limit. Four-quadrant and polar analysis revealed poor trending ability for most algorithms before and after CPB. The Liljestrand-Zander algorithm revealed the best reliability. Conclusions. Estimation of CO by nine different pulse contour algorithms revealed poor accuracy compared with transpulmonary thermodilution. Furthermore, the less-invasive algorithms showed an insufficient capability for trending hemodynamic changes before and after CPB. The Liljestrand-Zander algorithm demonstrated the highest reliability. This trial is registered with NCT02438228 (ClinicalTrials.gov.

  3. Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure.

    Science.gov (United States)

    Roth, Sebastian; Fox, Henrik; Fuchs, Uwe; Schulz, Uwe; Costard-Jäckle, Angelika; Gummert, Jan F; Horstkotte, Dieter; Oldenburg, Olaf; Bitter, Thomas

    2018-05-01

    Determination of cardiac output (CO) is essential in diagnosis and management of heart failure (HF). The gold standard to obtain CO is invasive assessment via thermodilution (TD). Noninvasive pulse contour analysis (NPCA) is supposed as a new method of CO determination. However, a validation of this method in HF is pending and performed in the present study. Patients with chronic-stable HF and reduced left ventricular ejection fraction (LVEF ≤ 45%; HF-REF) underwent right heart catheterization including TD. NPCA using the CNAP Monitor (V5.2.14, CNSystems Medizintechnik AG) was performed simultaneously. Three standardized TD measurements were compared with simultaneous auto-calibrated NPCA CO measurements. In total, 84 consecutive HF-REF patients were enrolled prospectively in this study. In 4 patients (5%), TD was not successful and for 22 patients (26%, 18 with left ventricular assist device), no NPCA signal could be obtained. For the remaining 58 patients, Bland-Altman analysis revealed a mean bias of + 1.92 L/min (limits of agreement ± 2.28 L/min, percentage error 47.4%) for CO. With decreasing cardiac index, as determined by the gold standard of TD, there was an increasing gap between CO values obtained by TD and NPCA (r = - 0.75, p TD-CI classified 52 (90%) patients to have a reduced CI (REF patients, auto-calibrated NPCA systematically overestimates CO with decrease in cardiac function. Therefore, to date, NPCA cannot be recommended in this cohort.

  4. SU-E-J-129: Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation

    International Nuclear Information System (INIS)

    Zhou, R; Yang, J; Pan, T; Milgrom, S; Pinnix, C; Shi, A; Yang, J; Liu, Y; Nguyen, Q; Gomez, D; Dabaja, B; Balter, P; Court, L; Liao, Z

    2015-01-01

    Purpose: To develop a set of atlases for automatic contouring of cardiac structures to determine heart radiation dose and the associated toxicity. Methods: Six thoracic cancer patients with both contrast and non-contrast CT images were acquired for this study. Eight radiation oncologists manually and independently delineated cardiac contours on the non-contrast CT by referring to the fused contrast CT and following the RTOG 1106 atlas contouring guideline. Fifteen regions of interest (ROIs) were delineated, including heart, four chambers, four coronary arteries, pulmonary artery and vein, inferior and superior vena cava, and ascending and descending aorta. Individual expert contours were fused using the simultaneous truth and performance level estimation (STAPLE) algorithm for each ROI and each patient. The fused contours became atlases for an in-house multi-atlas segmentation. Using leave-one-out test, we generated auto-segmented contours for each ROI and each patient. The auto-segmented contours were compared with the fused contours using the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Results: Inter-observer variability was not obvious for heart, chambers, and aorta but was large for other structures that were not clearly distinguishable on CT image. The average DSC between individual expert contours and the fused contours were less than 50% for coronary arteries and pulmonary vein, and the average MSD were greater than 4.0 mm. The largest MSD of expert contours deviating from the fused contours was 2.5 cm. The mean DSC and MSD of auto-segmented contours were within one standard deviation of expert contouring variability except the right coronary artery. The coronary arteries, vena cava, and pulmonary vein had DSC<70% and MSD>3.0 mm. Conclusion: A set of cardiac atlases was created for cardiac automatic contouring, the accuracy of which was comparable to the variability in expert contouring. However, substantial modification may need

  5. [Effects of application of pulse contour cardiac output monitoring technology in early treatment of patients with large area burns].

    Science.gov (United States)

    Wang, D Y; Xie, W G; Xi, M M; Li, Z; Wang, B

    2018-01-20

    Objective: To analyze the changes and relationship of early hemodynamic indexes of patients with large area burns monitored by pulse contour cardiac output (PiCCO) monitoring technology, so as to assess the guiding value of this technology in the treatment of patients with large area burns during shock period. Methods: Eighteen patients with large area burns, confirming to the study criteria, were admitted to our unit from May 2016 to May 2017. Pulse contour cardiac output index (PCCI), systemic vascular resistance index (SVRI), global end-diastolic volume index (GEDVI), and extravascular lung water index (EVLWI) of patients were monitored by PiCCO instrument from admission to post injury day (PID) 7, and they were calibrated and recorded once every four hours. The fluid infusion coefficients of patients at the first and second 24 hours post injury were calculated. The blood lactic acid values of patients from PID 1 to 7 were also recorded. The correlations among PCCI, SVRI, and GEDVI as well as the correlation between SVRI and blood lactic acid of these 18 patients were analyzed. Prognosis of patients were recorded. Data were processed with one-way analysis of variance, single sample t test and Bonferroni correction, Pearson correlation analysis, and Spearman rank correlation analysis. Results: (1) There was statistically significant difference in PCCI value of patients from post injury hour (PIH) 4 to 168 ( F =7.428, P 0.05). (2) There was statistically significant difference in SVRI value of patients from PIH 4 to 168 ( F =7.863, P 0.05). (3) There was no statistically significant difference in the GEDVI values of patients from PIH 4 to 168 ( F =0.704, P >0.05). The GEDVI values of patients at PIH 8, 12, 16, 20, and 24 were significantly lower than normal value ( t =-3.112, -3.554, -2.969, -2.450, -2.476, P 0.05). (4) There was statistically significant difference in EVLWI value of patients from PIH 4 to 168 ( F =1.859, P 0.05). (5) The fluid infusion

  6. Pulse contour analysis of arterial waveform in a high fidelity human patient simulator.

    Science.gov (United States)

    Persona, Paolo; Saraceni, Elisabetta; Facchin, Francesca; Petranzan, Enrico; Parotto, Matteo; Baratto, Fabio; Ori, Carlo; Rossi, Sandra

    2017-10-03

    The measurement of cardiac output (CO) may be useful to improve the assessment of hemodynamics during simulated scenarios. The purpose of this study was to evaluate the feasibility of introducing an uncalibrated pulse contour device (MostCare, Vytech, Vygon, Padova, Italy) into the simulation environment. MostCare device was plugged to a clinical monitor and connected to the METI human patient simulator (HPS) to obtain a continuous arterial waveform analysis and CO calculation. In six different simulated clinical scenarios (baseline, ventricular failure, vasoplegic shock, hypertensive crisis, hypovolemic shock and aortic stenosis), the HPS-CO and the MostCare-CO were simultaneously recorded. The level of concordance between the two methods was assessed by the Bland and Altman analysis. 150-paired CO values were obtained. The HPS-CO values ranged from 2.3 to 6.6 L min -1 and the MostCare-CO values from 2.8 to 6.4 L min -1 . The mean difference between HPS-CO and MostCare-CO was - 0.3 L min -1 and the limits of agreement were - 1.5 and 0.9 L min -1 . The percentage of error was 23%. A good correlation between HPS-CO and MostCare-CO was observed in each scenario of the study (r = 0.88). Although MostCare-CO tended to underestimate the CO over the study period, good agreements were found between the two methods. Therefore, a pulse contour device can be integrated into the simulation environment, offering the opportunity to create new simulated clinical settings.

  7. SU-F-T-405: Development of a Rapid Cardiac Contouring Tool Using Landmark-Driven Modeling

    International Nuclear Information System (INIS)

    Pelletier, C; Jung, J; Mosher, E; Lee, C; Lee, C

    2016-01-01

    Purpose: This study aims to develop a tool to rapidly delineate cardiac substructures for use in dosimetry for large-scale clinical trial or epidemiological investigations. The goal is to produce a system that can semi-automatically delineate nine cardiac structures to a reasonable accuracy within a couple of minutes. Methods: The cardiac contouring tool employs a Most Similar Atlas method, where a selection criterion is used to pre-select the most similar model to the patient from a library of pre-defined atlases. Sixty contrast-enhanced cardiac computed tomography angiography (CTA) scans (30 male and 30 female) were manually contoured to serve as the atlas library. For each CTA 12 structures were delineated. Kabsch algorithm was used to compute the optimum rotation and translation matrices between the patient and atlas. Minimum root mean squared distance between the patient and atlas after transformation was used to select the most-similar atlas. An initial study using 10 CTA sets was performed to assess system feasibility. Leave-one patient out method was performed, and fit criteria were calculated to evaluate the fit accuracy compared to manual contours. Results: For the pilot study, mean dice indices of .895 were achieved for the whole heart, .867 for the ventricles, and .802 for the atria. In addition, mean distance was measured via the chord length distribution (CLD) between ground truth and the atlas structures for the four coronary arteries. The mean CLD for all coronary arteries was below 14mm, with the left circumflex artery showing the best agreement (7.08mm). Conclusion: The cardiac contouring tool is able to delineate cardiac structures with reasonable accuracy in less than 90 seconds. Pilot data indicates that the system is able to delineate the whole heart and ventricles within a reasonable accuracy using even a limited library. We are extending the atlas sets to 60 adult males and females in total.

  8. SU-F-T-405: Development of a Rapid Cardiac Contouring Tool Using Landmark-Driven Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Pelletier, C; Jung, J [East Carolina University Greenville, NC (United States); Mosher, E; Lee, C [National Cancer Institute, Rockville, MD (United States); Lee, C [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: This study aims to develop a tool to rapidly delineate cardiac substructures for use in dosimetry for large-scale clinical trial or epidemiological investigations. The goal is to produce a system that can semi-automatically delineate nine cardiac structures to a reasonable accuracy within a couple of minutes. Methods: The cardiac contouring tool employs a Most Similar Atlas method, where a selection criterion is used to pre-select the most similar model to the patient from a library of pre-defined atlases. Sixty contrast-enhanced cardiac computed tomography angiography (CTA) scans (30 male and 30 female) were manually contoured to serve as the atlas library. For each CTA 12 structures were delineated. Kabsch algorithm was used to compute the optimum rotation and translation matrices between the patient and atlas. Minimum root mean squared distance between the patient and atlas after transformation was used to select the most-similar atlas. An initial study using 10 CTA sets was performed to assess system feasibility. Leave-one patient out method was performed, and fit criteria were calculated to evaluate the fit accuracy compared to manual contours. Results: For the pilot study, mean dice indices of .895 were achieved for the whole heart, .867 for the ventricles, and .802 for the atria. In addition, mean distance was measured via the chord length distribution (CLD) between ground truth and the atlas structures for the four coronary arteries. The mean CLD for all coronary arteries was below 14mm, with the left circumflex artery showing the best agreement (7.08mm). Conclusion: The cardiac contouring tool is able to delineate cardiac structures with reasonable accuracy in less than 90 seconds. Pilot data indicates that the system is able to delineate the whole heart and ventricles within a reasonable accuracy using even a limited library. We are extending the atlas sets to 60 adult males and females in total.

  9. Extraction and analysis of left ventricular contours in cardiac radionuclide angiographies

    International Nuclear Information System (INIS)

    Jouan, A.

    1991-01-01

    The analysis of cardiac scintigraphic sequences is commonly realized with the help of functional or parametric images. The decomposition of the original sequence into a linear combination of the main temporal behaviors yields, after orthogonalization, a set of parametric images representing the pure temporal behaviors present in the original data. The properties of these images are used to extract automatically the left ventricular boundary. The Fourier Descriptors method is then used to get a quantified analysis of the shape of the ventricle. Because of their property of invariance by change of scale, the Fourier descriptors method applied on a sequence of left ventricular contours yields a quantified assessment of the cardiac contraction

  10. SU-E-J-134: Optimizing Technical Parameters for Using Atlas Based Automatic Segmentation for Evaluation of Contour Accuracy Experience with Cardiac Structures From NRG Oncology/RTOG 0617

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J; Gong, Y; Bar-Ad, V; Giaddui, T; Galvin, J; Xiao, Y [Thomas Jefferson University, Philadelphia, PA (United States); Hu, C [NRG oncology, Philadelphia, PA (United States); Gore, E; Wheatley, M [Medical College of Wisconsin, Milwaukee, WI (United States); Witt, J; Robinson, C; Bradley, J [Washington University in St. Louis School of Medicine, St. Louis, MO (United States); Kong, F [Georgia Regents University, Augusta, GA (Georgia)

    2015-06-15

    Purpose: Accurate contour delineation is crucial for radiotherapy. Atlas based automatic segmentation tools can be used to increase the efficiency of contour accuracy evaluation. This study aims to optimize technical parameters utilized in the tool by exploring the impact of library size and atlas number on the accuracy of cardiac contour evaluation. Methods: Patient CT DICOMs from RTOG 0617 were used for this study. Five experienced physicians delineated the cardiac structures including pericardium, atria and ventricles following an atlas guideline. The consistency of cardiac structured delineation using the atlas guideline was verified by a study with four observers and seventeen patients. The CT and cardiac structure DICOM files were then used for the ABAS technique.To study the impact of library size (LS) and atlas number (AN) on automatic contour accuracy, automatic contours were generated with varied technique parameters for five randomly selected patients. Three LS (20, 60, and 100) were studied using commercially available software. The AN was four, recommended by the manufacturer. Using the manual contour as the gold standard, Dice Similarity Coefficient (DSC) was calculated between the manual and automatic contours. Five-patient averaged DSCs were calculated for comparison for each cardiac structure.In order to study the impact of AN, the LS was set 100, and AN was tested from one to five. The five-patient averaged DSCs were also calculated for each cardiac structure. Results: DSC values are highest when LS is 100 and AN is four. The DSC is 0.90±0.02 for pericardium, 0.75±0.06 for atria, and 0.86±0.02 for ventricles. Conclusion: By comparing DSC values, the combination AN=4 and LS=100 gives the best performance. This project was supported by NCI grants U24CA12014, U24CA180803, U10CA180868, U10CA180822, PA CURE grant and Bristol-Myers Squibb and Eli Lilly.

  11. Lagrangian displacement tracking using a polar grid between endocardial and epicardial contours for cardiac strain imaging.

    Science.gov (United States)

    Ma, Chi; Varghese, Tomy

    2012-04-01

    Accurate cardiac deformation analysis for cardiac displacement and strain imaging over time requires Lagrangian description of deformation of myocardial tissue structures. Failure to couple the estimated displacement and strain information with the correct myocardial tissue structures will lead to erroneous result in the displacement and strain distribution over time. Lagrangian based tracking in this paper divides the tissue structure into a fixed number of pixels whose deformation is tracked over the cardiac cycle. An algorithm that utilizes a polar-grid generated between the estimated endocardial and epicardial contours for cardiac short axis images is proposed to ensure Lagrangian description of the pixels. Displacement estimates from consecutive radiofrequency frames were then mapped onto the polar grid to obtain a distribution of the actual displacement that is mapped to the polar grid over time. A finite element based canine heart model coupled with an ultrasound simulation program was used to verify this approach. Segmental analysis of the accumulated displacement and strain over a cardiac cycle demonstrate excellent agreement between the ideal result obtained directly from the finite element model and our Lagrangian approach to strain estimation. Traditional Eulerian based estimation results, on the other hand, show significant deviation from the ideal result. An in vivo comparison of the displacement and strain estimated using parasternal short axis views is also presented. Lagrangian displacement tracking using a polar grid provides accurate tracking of myocardial deformation demonstrated using both finite element and in vivo radiofrequency data acquired on a volunteer. In addition to the cardiac application, this approach can also be utilized for transverse scans of arteries, where a polar grid can be generated between the contours delineating the outer and inner wall of the vessels from the blood flowing though the vessel.

  12. A cardiac contouring atlas for radiotherapy

    DEFF Research Database (Denmark)

    Duane, Frances; Aznar, Marianne C; Bartlett, Freddie

    2017-01-01

    defined from cardiology models and agreed by two cardiologists. Reference atlas contours were delineated and written guidelines prepared. Six radiation oncologists tested the atlas. Spatial variation was assessed using the DICE similarity coefficient (DSC) and the directed Hausdorff average distance (d→H,avg......-observer contour separation (mean d→H,avg) was 1.5-2.2mm for left ventricular segments and 1.3-5.1mm for coronary artery segments. This spatial variation resulted in

  13. Quantification of left ventricular volumes from cardiac cine MRI using active contour model combined with gradient vector flow

    International Nuclear Information System (INIS)

    Tanki, Nobuyoshi; Murase, Kenya; Kumashiro, Masayuki; Momoi, Risa; Yang, Xiaomei; Tabuchi, Takashi; Nagayama, Masako; Watanabe, Yuji

    2005-01-01

    We investigated the feasibility of combining the active contour model with gradient vector flow (Snakes-GVF) to estimate left ventricular (LV) volumes from cardiac cine magnetic resonance imaging (MRI). MRI data were acquired from 27 patients, including 14 adults (9 men, 5 women, 55.0±23.3 years) and 13 children (10 boys, 3 girls, 2.7±2.1 years) using Gyroscan Intera (1.5 Tesla, Philips Medical Systems). LV volumes were calculated by adding the areas surrounded by the contour extracted by Snakes-GVF and compared with volumes estimated by manual tracing. Those estimated by Snakes-GVF [y (mL)] correlated well with those estimated by manual tracing [x (mL)]. In adult cases, the regression equation and correlation coefficient were y=1.008x-0.517 and 0.996, respectively. In pediatric cases, they were y=1.174x-2.542 and 0.992, respectively. In conclusion, Snakes-GVF is a powerful and useful tool for quantifying LV volumes using cardiac MRI. (author)

  14. Autonomic Nervous System Responses to Concussion: Arterial Pulse Contour Analysis

    Directory of Open Access Journals (Sweden)

    Michael F La Fountaine

    2016-02-01

    Full Text Available The arterial pulse wave (APW has a distinct morphology whose contours reflect dynamics in cardiac function and peripheral vascular tone as a result of sympathetic nervous system (SNS control. With a transition from rest to increased metabolic demand, the expected augmentation of SNS outflow will not only affect arterial blood pressure and heart rate, it will also induce changes to the contours of the APW. Following a sports concussion, a transient state cardiovascular autonomic dysfunction is present. How this state affects the APW, has yet to be described. A prospective, parallel-group study on cardiovascular autonomic control (i.e., digital electrocardiogram and continuous beat-to-beat blood pressure was performed in the seated upright position in ten athletes with concussion and 7 non-injured control athletes. Changes in APW were compared at rest and during the first 60 seconds (F60 of an isometric handgrip test (IHGT in concussed athletes and non-injured controls within 48 hours (48hr and 1 week (1wk of injury. The concussion group was further separated by the length of time until they were permitted to return to play (RTP>1wk; RTP≤1wk. SysSlope, an indirect measurement of stroke volume, was significantly lower in the concussion group at rest and during F60 at 48hr and 1wk; a paradoxical decline in SysSlope occurred at each visit during the transition from rest to IHGT F60. The RTP>1wk group had lower SysSlope (405±200; 420±88; 454±236 mmHg/s, respectively at rest 48hr compared to the RTP≤1wk and controls. Similarly at 48hr rest, several measurements of arterial stiffness were abnormal in RTP>1wk compared to RTP≤1wk and controls: Peak-to-Notch Latency (0.12±0.04; 0.16±0.02; 0.17±0.05, respectively, Notch Relative Amplitude (0.70±0.03; 0.71±0.04; 0.66±0.14, respectively and Stiffness Index (6.4±0.2; 5.7±0.4; 5.8±0.5, respectively. Use of APW revealed that concussed athletes have a transient increase in peripheral artery

  15. Technique of experimental measurements of the optical thickness of a pulse discharge plasma channel in water on a contour reabsorption lines of hydrogen Hα

    Directory of Open Access Journals (Sweden)

    O. A. Fedorovich

    2010-03-01

    Full Text Available In this work the results of development and application of the technique of experimental definition of optical thickness (τ of the pulse discharge plasma channel in water which are based on the distribution of radiation intensities on contour reabsorption lines of hydrogen Ha (656.3 nm are given. Optical thickness of continues spectrum was defined by extrapolation of intensities in far wing of contour reabsorption lines of hydrogen Ha, where t value did not vary any more, and the line smoothly transferred in continuous spectrum. The atomic concentration Na, received on a method of definition of t on a contour reabsorption lines of hydrogen Ha., agreed with calculation obtained from the equation of the plasma state. The recommendations on the correct definition of optical thickness of plasma of pulse discharge in liquids are given.

  16. Cardiac output during exercise

    DEFF Research Database (Denmark)

    Siebenmann, C; Rasmussen, P.; Sørensen, H.

    2015-01-01

    Several techniques assessing cardiac output (Q) during exercise are available. The extent to which the measurements obtained from each respective technique compares to one another, however, is unclear. We quantified Q simultaneously using four methods: the Fick method with blood obtained from...... the right atrium (Q(Fick-M)), Innocor (inert gas rebreathing; Q(Inn)), Physioflow (impedance cardiography; Q(Phys)), and Nexfin (pulse contour analysis; Q(Pulse)) in 12 male subjects during incremental cycling exercise to exhaustion in normoxia and hypoxia (FiO2  = 12%). While all four methods reported...... a progressive increase in Q with exercise intensity, the slopes of the Q/oxygen uptake (VO2) relationship differed by up to 50% between methods in both normoxia [4.9 ± 0.3, 3.9 ± 0.2, 6.0 ± 0.4, 4.8 ± 0.2 L/min per L/min (mean ± SE) for Q(Fick-M), Q(Inn), QP hys and Q(Pulse), respectively; P = 0...

  17. Reliability of pulse oximetry during cardiopulmonary resuscitation in a piglet model of neonatal cardiac arrest.

    Science.gov (United States)

    Hassan, Mohammad Ahmad; Mendler, Marc; Maurer, Miriam; Waitz, Markus; Huang, Li; Hummler, Helmut D

    2015-01-01

    Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during cardiopulmonary resuscitation (CPR). In a prospective cohort study in 30 healthy newborn piglets, cardiac arrest was induced, and thereafter each piglet received CPR for 20 min. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2). Arterial blood was analyzed for functional oxygenation (SaO2) every 2 min. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. Bias values were decreased at the baseline measurements (mean: 2.5 ± 4.6%) with higher precision and accuracy compared with values across the experiment. Two minutes after cardiac arrest, there was a marked decrease in precision and accuracy as well as an increase in bias up to 13 ± 34%, reaching a maximum of 45.6 ± 28.3% after 10 min over a mean SaO2 range of 29-58%. Pulse oximetry showed increased bias and decreased accuracy and precision during CPR in a model of neonatal cardiac arrest. We recommend further studies to clarify the exact mechanisms of these false readings to improve reliability of pulse oximetry during the marked desaturation and hypoperfusion found during CPR. © 2014 S. Karger AG, Basel.

  18. TU-H-CAMPUS-JeP2-05: Can Automatic Delineation of Cardiac Substructures On Noncontrast CT Be Used for Cardiac Toxicity Analysis?

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Y; Liao, Z; Jiang, W; Gomez, D; Williamson, R; Court, L; Yang, J [MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To evaluate the feasibility of using an automatic segmentation tool to delineate cardiac substructures from computed tomography (CT) images for cardiac toxicity analysis for non-small cell lung cancer (NSCLC) patients after radiotherapy. Methods: A multi-atlas segmentation tool developed in-house was used to delineate eleven cardiac substructures including the whole heart, four heart chambers, and six greater vessels automatically from the averaged 4DCT planning images for 49 NSCLC patients. The automatic segmented contours were edited appropriately by two experienced radiation oncologists. The modified contours were compared with the auto-segmented contours using Dice similarity coefficient (DSC) and mean surface distance (MSD) to evaluate how much modification was needed. In addition, the dose volume histogram (DVH) of the modified contours were compared with that of the auto-segmented contours to evaluate the dosimetric difference between modified and auto-segmented contours. Results: Of the eleven structures, the averaged DSC values ranged from 0.73 ± 0.08 to 0.95 ± 0.04 and the averaged MSD values ranged from 1.3 ± 0.6 mm to 2.9 ± 5.1mm for the 49 patients. Overall, the modification is small. The pulmonary vein (PV) and the inferior vena cava required the most modifications. The V30 (volume receiving 30 Gy or above) for the whole heart and the mean dose to the whole heart and four heart chambers did not show statistically significant difference between modified and auto-segmented contours. The maximum dose to the greater vessels did not show statistically significant difference except for the PV. Conclusion: The automatic segmentation of the cardiac substructures did not require substantial modification. The dosimetric evaluation showed no statistically significant difference between auto-segmented and modified contours except for the PV, which suggests that auto-segmented contours for the cardiac dose response study are feasible in the clinical

  19. TU-H-CAMPUS-JeP2-05: Can Automatic Delineation of Cardiac Substructures On Noncontrast CT Be Used for Cardiac Toxicity Analysis?

    International Nuclear Information System (INIS)

    Luo, Y; Liao, Z; Jiang, W; Gomez, D; Williamson, R; Court, L; Yang, J

    2016-01-01

    Purpose: To evaluate the feasibility of using an automatic segmentation tool to delineate cardiac substructures from computed tomography (CT) images for cardiac toxicity analysis for non-small cell lung cancer (NSCLC) patients after radiotherapy. Methods: A multi-atlas segmentation tool developed in-house was used to delineate eleven cardiac substructures including the whole heart, four heart chambers, and six greater vessels automatically from the averaged 4DCT planning images for 49 NSCLC patients. The automatic segmented contours were edited appropriately by two experienced radiation oncologists. The modified contours were compared with the auto-segmented contours using Dice similarity coefficient (DSC) and mean surface distance (MSD) to evaluate how much modification was needed. In addition, the dose volume histogram (DVH) of the modified contours were compared with that of the auto-segmented contours to evaluate the dosimetric difference between modified and auto-segmented contours. Results: Of the eleven structures, the averaged DSC values ranged from 0.73 ± 0.08 to 0.95 ± 0.04 and the averaged MSD values ranged from 1.3 ± 0.6 mm to 2.9 ± 5.1mm for the 49 patients. Overall, the modification is small. The pulmonary vein (PV) and the inferior vena cava required the most modifications. The V30 (volume receiving 30 Gy or above) for the whole heart and the mean dose to the whole heart and four heart chambers did not show statistically significant difference between modified and auto-segmented contours. The maximum dose to the greater vessels did not show statistically significant difference except for the PV. Conclusion: The automatic segmentation of the cardiac substructures did not require substantial modification. The dosimetric evaluation showed no statistically significant difference between auto-segmented and modified contours except for the PV, which suggests that auto-segmented contours for the cardiac dose response study are feasible in the clinical

  20. A melodic contour repeatedly experienced by human near-term fetuses elicits a profound cardiac reaction one month after birth.

    Science.gov (United States)

    Granier-Deferre, Carolyn; Bassereau, Sophie; Ribeiro, Aurélie; Jacquet, Anne-Yvonne; Decasper, Anthony J

    2011-02-23

    Human hearing develops progressively during the last trimester of gestation. Near-term fetuses can discriminate acoustic features, such as frequencies and spectra, and process complex auditory streams. Fetal and neonatal studies show that they can remember frequently recurring sounds. However, existing data can only show retention intervals up to several days after birth. Here we show that auditory memories can last at least six weeks. Experimental fetuses were given precisely controlled exposure to a descending piano melody twice daily during the 35(th), 36(th), and 37(th) weeks of gestation. Six weeks later we assessed the cardiac responses of 25 exposed infants and 25 naive control infants, while in quiet sleep, to the descending melody and to an ascending control piano melody. The melodies had precisely inverse contours, but similar spectra, identical duration, tempo and rhythm, thus, almost identical amplitude envelopes. All infants displayed a significant heart rate change. In exposed infants, the descending melody evoked a cardiac deceleration that was twice larger than the decelerations elicited by the ascending melody and by both melodies in control infants. Thus, 3-weeks of prenatal exposure to a specific melodic contour affects infants 'auditory processing' or perception, i.e., impacts the autonomic nervous system at least six weeks later, when infants are 1-month old. Our results extend the retention interval over which a prenatally acquired memory of a specific sound stream can be observed from 3-4 days to six weeks. The long-term memory for the descending melody is interpreted in terms of enduring neurophysiological tuning and its significance for the developmental psychobiology of attention and perception, including early speech perception, is discussed.

  1. A melodic contour repeatedly experienced by human near-term fetuses elicits a profound cardiac reaction one month after birth.

    Directory of Open Access Journals (Sweden)

    Carolyn Granier-Deferre

    2011-02-01

    Full Text Available Human hearing develops progressively during the last trimester of gestation. Near-term fetuses can discriminate acoustic features, such as frequencies and spectra, and process complex auditory streams. Fetal and neonatal studies show that they can remember frequently recurring sounds. However, existing data can only show retention intervals up to several days after birth.Here we show that auditory memories can last at least six weeks. Experimental fetuses were given precisely controlled exposure to a descending piano melody twice daily during the 35(th, 36(th, and 37(th weeks of gestation. Six weeks later we assessed the cardiac responses of 25 exposed infants and 25 naive control infants, while in quiet sleep, to the descending melody and to an ascending control piano melody. The melodies had precisely inverse contours, but similar spectra, identical duration, tempo and rhythm, thus, almost identical amplitude envelopes. All infants displayed a significant heart rate change. In exposed infants, the descending melody evoked a cardiac deceleration that was twice larger than the decelerations elicited by the ascending melody and by both melodies in control infants.Thus, 3-weeks of prenatal exposure to a specific melodic contour affects infants 'auditory processing' or perception, i.e., impacts the autonomic nervous system at least six weeks later, when infants are 1-month old. Our results extend the retention interval over which a prenatally acquired memory of a specific sound stream can be observed from 3-4 days to six weeks. The long-term memory for the descending melody is interpreted in terms of enduring neurophysiological tuning and its significance for the developmental psychobiology of attention and perception, including early speech perception, is discussed.

  2. Development of automatic extraction method of left ventricular contours on long axis view MR cine images

    International Nuclear Information System (INIS)

    Utsunomiya, Shinichi; Iijima, Naoto; Yamasaki, Kazunari; Fujita, Akinori

    1995-01-01

    In the MRI cardiac function analysis, left ventricular volume curves and diagnosis parameters are obtained by extracting the left ventricular cavities as regions of interest (ROI) from long axis view MR cine images. The ROI extractions had to be done by manual operations, because automatization of the extraction is difficult. A long axis view left ventricular contour consists of a cardiac wall part and an aortic valve part. The above mentioned difficulty is due to the decline of contrast on the cardiac wall part, and the disappearance of edge on the aortic valve part. In this paper, we report a new automatic extraction method for long axis view MR cine images, which needs only 3 manually indicated points on the 1st image to extract all the contours from the total sequence of images. At first, candidate points of a contour are detected by edge detection. Then, selecting the best matched combination of candidate points by Dynamic Programming, the cardiac wall part is automatically extracted. The aortic valve part is manually extracted for the 1st image by indicating both the end points, and is automatically extracted for the rest of the images, by utilizing the aortic valve motion characteristics throughout a cardiac cycle. (author)

  3. Comparison of cardiac gating and refocusing pulses for correction of cerebrospinal fluid pulsation artifacts in MR images

    International Nuclear Information System (INIS)

    Modic, M.T.; Haacke, E.M.; Lenz, G.W.; Masaryk, T.; Kaufman, B.; Ross, J.S.

    1986-01-01

    This study compared cardiac gating and additional refocusing gradient pulses in combination or alone for correction of cerebrospinal fluid (CSF) pulsation artifacts in both normal volunteers and in patients with suspected spinal pathology. Refocusing pulses or cardiac gating when used alone produced a decrease in ghosting artifacts on sagittal images and reduced the nonuniformity of the CSF signal on axial images. There is improved thin-section T2 imaging of the cord with long TEs and as few as one excitation. The refocusing pulses reduced ghosting artifacts also from respiratory motion and enhanced the CSF signal with shorter TRs leading to increased CSF contrast. When used together, the results were significantly better than either alone. Refocusing schemes can be used with any TR, do not require gating, and are now routinely employed at the authors' institution

  4. Short repetition time multiband echo-planar imaging with simultaneous pulse recording allows dynamic imaging of the cardiac pulsation signal.

    Science.gov (United States)

    Tong, Yunjie; Hocke, Lia M; Frederick, Blaise deB

    2014-11-01

    Recently developed simultaneous multislice echo-planar imaging (EPI) sequences permit imaging of the whole brain at short repetition time (TR), allowing the cardiac fluctuations to be fully sampled in blood-oxygen-level dependent functional MRI (BOLD fMRI). A novel low computational analytical method was developed to dynamically map the passage of the pulsation signal through the brain and visualize the whole cerebral vasculature affected by the pulse signal. This algorithm is based on a simple combination of fast BOLD fMRI and the scanner's own built-in pulse oximeter. Multiple, temporally shifted copies of the pulse oximeter data (with 0.08 s shifting step and coverage of a 1-s span) were downsampled and used as cardiac pulsation regressors in a general linear model based analyses (FSL) of the fMRI data. The resulting concatenated z-statistics maps show the voxels that are affected as the cardiac signal travels through the brain. Many voxels were highly correlated with the pulsation regressor or its temporally shifted version. The dynamic and static cardiac pulsation maps obtained from both the task and resting state scans, resembled cerebral vasculature. The results demonstrated: (i) cardiac pulsation significantly affects most voxels in the brain; (ii) combining fast fMRI and this analytical method can reveal additional clinical information to functional studies. Copyright © 2013 Wiley Periodicals, Inc.

  5. LV challenge LKEB contribution : fully automated myocardial contour detection

    NARCIS (Netherlands)

    Wijnhout, J.S.; Hendriksen, D.; Assen, van H.C.; Geest, van der R.J.

    2009-01-01

    In this paper a contour detection method is described and evaluated on the evaluation data sets of the Cardiac MR Left Ventricle Segmentation Challenge as part of MICCAI 2009s 3D Segmentation Challenge for Clinical Applications. The proposed method, using 2D AAM and 3D ASM, performs a fully

  6. Development and Validation of a Heart Atlas to Study Cardiac Exposure to Radiation Following Treatment for Breast Cancer

    International Nuclear Information System (INIS)

    Feng, Mary; Moran, Jean M.; Koelling, Todd; Chughtai, Aamer; Chan, June L.; Freedman, Laura; Hayman, James A.; Jagsi, Reshma; Jolly, Shruti; Larouere, Janice; Soriano, Julie; Marsh, Robin; Pierce, Lori J.

    2011-01-01

    Purpose: Cardiac toxicity is an important sequela of breast radiotherapy. However, the relationship between dose to cardiac structures and subsequent toxicity has not been well defined, partially due to variations in substructure delineation, which can lead to inconsistent dose reporting and the failure to detect potential correlations. Here we have developed a heart atlas and evaluated its effect on contour accuracy and concordance. Methods and Materials: A detailed cardiac computed tomography scan atlas was developed jointly by cardiology, cardiac radiology, and radiation oncology. Seven radiation oncologists were recruited to delineate the whole heart, left main and left anterior descending interventricular branches, and right coronary arteries on four cases before and after studying the atlas. Contour accuracy was assessed by percent overlap with gold standard atlas volumes. The concordance index was also calculated. Standard radiation fields were applied. Doses to observer-contoured cardiac structures were calculated and compared with gold standard contour doses. Pre- and post-atlas values were analyzed using a paired t test. Results: The cardiac atlas significantly improved contour accuracy and concordance. Percent overlap and concordance index of observer-contoured cardiac and gold standard volumes were 2.3-fold improved for all structures (p < 0.002). After application of the atlas, reported mean doses to the whole heart, left main artery, left anterior descending interventricular branch, and right coronary artery were within 0.1, 0.9, 2.6, and 0.6 Gy, respectively, of gold standard doses. Conclusions: This validated University of Michigan cardiac atlas may serve as a useful tool in future studies assessing cardiac toxicity and in clinical trials which include dose volume constraints to the heart.

  7. Multiple Active Contours Driven by Particle Swarm Optimization for Cardiac Medical Image Segmentation

    Science.gov (United States)

    Cruz-Aceves, I.; Aviña-Cervantes, J. G.; López-Hernández, J. M.; González-Reyna, S. E.

    2013-01-01

    This paper presents a novel image segmentation method based on multiple active contours driven by particle swarm optimization (MACPSO). The proposed method uses particle swarm optimization over a polar coordinate system to increase the energy-minimizing capability with respect to the traditional active contour model. In the first stage, to evaluate the robustness of the proposed method, a set of synthetic images containing objects with several concavities and Gaussian noise is presented. Subsequently, MACPSO is used to segment the human heart and the human left ventricle from datasets of sequential computed tomography and magnetic resonance images, respectively. Finally, to assess the performance of the medical image segmentations with respect to regions outlined by experts and by the graph cut method objectively and quantifiably, a set of distance and similarity metrics has been adopted. The experimental results demonstrate that MACPSO outperforms the traditional active contour model in terms of segmentation accuracy and stability. PMID:23762177

  8. Accurate computer-aided quantification of left ventricular parameters : experience in 1555 cardiac magnetic resonance studies from the Framingham Heart Study

    NARCIS (Netherlands)

    Hautvast, G.L.T.F.; Salton, C.J.; Chuang, M.L.; Breeuwer, M.; O'Donnel, C.J.; Manning, W.J.

    2011-01-01

    Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases.

  9. Contour forming of metals by laser peening

    Science.gov (United States)

    Hackel, Lloyd; Harris, Fritz

    2002-01-01

    A method and apparatus are provided for forming shapes and contours in metal sections by generating laser induced compressive stress on the surface of the metal workpiece. The laser process can generate deep compressive stresses to shape even thick components without inducing unwanted tensile stress at the metal surface. The precision of the laser-induced stress enables exact prediction and subsequent contouring of parts. A light beam of 10 to 100 J/pulse is imaged to create an energy fluence of 60 to 200 J/cm.sup.2 on an absorptive layer applied over a metal surface. A tamping layer of water is flowed over the absorptive layer. The absorption of laser light causes a plasma to form and consequently creates a shock wave that induces a deep residual compressive stress into the metal. The metal responds to this residual stress by bending.

  10. Pulse wave velocity and cardiac autonomic function in type 2 diabetes mellitus.

    Science.gov (United States)

    Chorepsima, Stamatina; Eleftheriadou, Ioanna; Tentolouris, Anastasios; Moyssakis, Ioannis; Protogerou, Athanasios; Kokkinos, Alexandros; Sfikakis, Petros P; Tentolouris, Nikolaos

    2017-05-19

    Increased carotid-femoral pulse wave velocity (PWV) has been associated with incident cardiovascular disease, independently of traditional risk factors. Cardiac autonomic dysfunction is a common complication of diabetes and has been associated with reduced aortic distensibility. However, the association of cardiac autonomic dysfunction with PWV is not known. In this study we examined the association between cardiac autonomic function and PWV in subjects with type 2 diabetes mellitus. A total of 290 patients with type 2 diabetes were examined. PWV was measured at the carotid-femoral segment with applanation tonometry. Central mean arterial blood pressure (MBP) was determined by the same apparatus. Participants were classified as having normal (n = 193) or abnormal (n = 97) PWV values using age-corrected values. Cardiac autonomic nervous system activity was determined by measurement of parameters of heart rate variability (HRV). Subjects with abnormal PWV were older, had higher arterial blood pressure and higher heart rate than those with normal PWV. Most of the values of HRV were significantly lower in subjects with abnormal than in those with normal PWV. Multivariate analysis, after controlling for various confounding factors, demonstrated that abnormal PWV was associated independently only with peripheral MBP [odds ratio (OR) 1.049, 95% confidence intervals (CI) 1.015-1.085, P = 0.005], central MBP (OR 1.052, 95% CI 1.016-1.088, P = 0.004), log total power (OR 0.490, 95% CI 0.258-0.932, P = 0.030) and log high frequency power (OR 0.546, 95% CI 0.301-0.991, P = 0.047). In subjects with type 2 diabetes, arterial blood pressure and impaired cardiac autonomic function is associated independently with abnormal PWV.

  11. Pair Fermi contour and high-temperature superconductivity

    CERN Document Server

    Belyavsky, V I

    2002-01-01

    The holes superconducting coupling with the pair high summarized pulse and the relative motion low pulses is considered with an account of the quasi-two-dimensional electron structure of the HTSC-cuprates with the clearly-pronounced nesting of the Fermi contour. The superconducting energy gap and the condensation energy are determined and their dependences on the doping level are qualitatively studied. It is shown that the energy gap takes place in some holes concentration area, limited on both sides. The superconducting state, whereby the condensation energy is positive, originates in the more narrower doping interval inside this area. The hole pair redistribution in the pulse space constitutes the cause of the superconducting state origination by the holes repulsive screened Coulomb interaction. The coupling mechanism discussed hereby, males it possible to explain qualitatively not only the phase diagram basic peculiarities but also the key experimental facts, related to the cuprate HTSC-materials

  12. Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Gardner, Stephen J; Wen, Ning; Kim, Jinkoo; Liu, Chang; Pradhan, Deepak; Aref, Ibrahim; Cattaneo, Richard II; Vance, Sean; Movsas, Benjamin; Chetty, Indrin J; Elshaikh, Mohamed A

    2015-01-01

    This study was designed to evaluate contouring variability of human-and deformable-generated contours on planning CT (PCT) and CBCT for ten patients with low-or intermediate-risk prostate cancer. For each patient in this study, five radiation oncologists contoured the prostate, bladder, and rectum, on one PCT dataset and five CBCT datasets. Consensus contours were generated using the STAPLE method in the CERR software package. Observer contours were compared to consensus contour, and contour metrics (Dice coefficient, Hausdorff distance, Contour Distance, Center-of-Mass [COM] Deviation) were calculated. In addition, the first day CBCT was registered to subsequent CBCT fractions (CBCTn: CBCT2–CBCT5) via B-spline Deformable Image Registration (DIR). Contours were transferred from CBCT1 to CBCTn via the deformation field, and contour metrics were calculated through comparison with consensus contours generated from human contour set. The average contour metrics for prostate contours on PCT and CBCT were as follows: Dice coefficient—0.892 (PCT), 0.872 (CBCT-Human), 0.824 (CBCT-Deformed); Hausdorff distance—4.75 mm (PCT), 5.22 mm (CBCT-Human), 5.94 mm (CBCT-Deformed); Contour Distance (overall contour)—1.41 mm (PCT), 1.66 mm (CBCT-Human), 2.30 mm (CBCT-Deformed); COM Deviation—2.01 mm (PCT), 2.78 mm (CBCT-Human), 3.45 mm (CBCT-Deformed). For human contours on PCT and CBCT, the difference in average Dice coefficient between PCT and CBCT (approx. 2%) and Hausdorff distance (approx. 0.5 mm) was small compared to the variation between observers for each patient (standard deviation in Dice coefficient of 5% and Hausdorff distance of 2.0 mm). However, additional contouring variation was found for the deformable-generated contours (approximately 5.0% decrease in Dice coefficient and 0.7 mm increase in Hausdorff distance relative to human-generated contours on CBCT). Though deformable contours provide a reasonable starting point for contouring

  13. The Development of Contour Interpolation: Evidence from Subjective Contours

    Science.gov (United States)

    Hadad, Bat-Sheva; Maurer, Daphne; Lewis, Terri L.

    2010-01-01

    Adults are skilled at perceiving subjective contours in regions without any local image information (e.g., [Ginsburg, 1975] and [Kanizsa, 1976]). Here we examined the development of this skill and the effect thereon of the support ratio (i.e., the ratio of the physically specified contours to the total contour length). Children (6-, 9-, and…

  14. Reliability of Pulse Oximetry during Progressive Hypoxia, Cardiopulmonary Resuscitation, and Recovery in a Piglet Model of Neonatal Hypoxic Cardiac Arrest.

    Science.gov (United States)

    Hassan, Mohammad Ahmad; Weber, Claudia; Waitz, Markus; Huang, Li; Hummler, Helmut D; Mendler, Marc Robin

    2017-01-01

    Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during progressive hypoxia, cardiac arrest, cardiopulmonary resuscitation (CPR), and after return of spontaneous circulation (ROSC). Thirty-three newborn piglets were exposed to hypoxia until asystole occurred and then resuscitated until ROSC. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2) with one sensor applied to the wrist of the right forelimb (FL) and another to the thigh of the left hind limb (HL). Arterial functional oxygen saturation (SaO2) was measured at baseline and at predefined intervals during each phase of the experiment. SpO2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO2 - SaO2) was beyond ±5%. Bias values were lower at the baseline measurements (-3.7 ± 2.3% in FL and -4.1 ± 3.4% in HL) as well as after ROSC (1.5 ± 4.2% in FL and 0.2 ± 4.6% in HL) with higher precision and accuracy than during other experiment phases. During hypoxia induction, cardiac arrest, and CPR, there was a marked decrease in precision and accuracy as well as an increase in bias up to 43 ± 26 and 56 ± 27% in FL and HL, respectively, over a range of SaO2 from 13 to 51%. Pulse oximetry showed increased bias and decreased accuracy and precision during marked hypoxemia in a model of neonatal hypoxic cardiac arrest. © 2017 S. Karger AG, Basel.

  15. Male Body Contouring.

    Science.gov (United States)

    Singh, Babu; Keaney, Terrence; Rossi, Anthony M

    2015-09-01

    Men are increasingly turning to dermatologists and plastic surgeons to request procedures that correct or enhance physical features. With the advent of this emerging new patient population, alterations in preexisting aesthetic techniques, gender-specific uses of existing devices and overall approaches need to be revisited and adapted to obtain results that are suitable for the male patient. Recently, body contouring has become one of the most sought out procedures by men. Although the majority of clinical studies involving body contouring esthetics are performed with female patients, gains from such studies can be extrapolated to men. Body contouring can be broadly classified as non-invasive or invasive, depending on the modality used. Non-invasive contouring is most frequently performed with devices that target subcutaneous adipose with focused electrical or thermal energy, including low-level laser, cryolipolysis, ultrasonography, and radiofrequency. Invasive body contouring modalities useful for male body contouring include liposuction, pectoral and abdominal wall etching, jawline fillers, synthetic deoxycholic acid injections, and solid silicone implants. The purpose of this review is to bring attention to the unique aspects, strategies, and modalities used in aesthetic body contouring for the male patient.

  16. Safety of mechanical chest compression devices AutoPulse and LUCAS in cardiac arrest: a randomized clinical trial for non-inferiority

    NARCIS (Netherlands)

    Koster, Rudolph W.; Beenen, Ludo F.; van der Boom, Esther B.; Spijkerboer, Anje M.; Tepaske, Robert; van der Wal, Allart C.; Beesems, Stefanie G.; Tijssen, Jan G.

    2017-01-01

    Aims Mechanical chest compression (CC) during cardiopulmonary resuscitation (CPR) with AutoPulse or LUCAS devices has not improved survival from cardiac arrest. Cohort studies suggest risk of excess damage. We studied safety of mechanical CC and determined possible excess damage compared with manual

  17. Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Transesophageal echocardiography (TEE is increasingly replacing thermodilution pulmonary artery catheters to assess hemodynamics in patients at high risk for cardiovascular morbidity. However, one of the drawbacks of TEE compared to pulmonary artery catheters is the inability to measure real time stroke volume (SV and cardiac output (CO continuously. The aim of the present proof of concept study was to validate a novel method of SV estimation, based on pulse wave velocity (PWV in patients undergoing cardiac surgery.This is a retrospective observational study. We measured pulse transit time by superimposing the radial arterial waveform onto the continuous wave Doppler waveform of the left ventricular outflow tract, and calculated SV (SVPWV using the transformed Bramwell-Hill equation. The SV measured by TEE (SVTEE was used as a reference.A total of 190 paired SV were measured from 28 patients. A strong correlation was observed between SVPWV and SVTEE with the coefficient of determination (R2 of 0.71. A mean difference between the two (bias was 3.70 ml with the limits of agreement ranging from -20.33 to 27.73 ml and a percentage error of 27.4% based on a Bland-Altman analysis. The concordance rate of two methods was 85.0% based on a four-quadrant plot. The angular concordance rate was 85.9% with radial limits of agreement (the radial sector that contained 95% of the data points of ± 41.5 degrees based on a polar plot.PWV based SV estimation yields reasonable agreement with SV measured by TEE. Further studies are required to assess its utility in different clinical situations.

  18. Automatic segmentation of the left ventricle in a cardiac MR short axis image using blind morphological operation

    Science.gov (United States)

    Irshad, Mehreen; Muhammad, Nazeer; Sharif, Muhammad; Yasmeen, Mussarat

    2018-04-01

    Conventionally, cardiac MR image analysis is done manually. Automatic examination for analyzing images can replace the monotonous tasks of massive amounts of data to analyze the global and regional functions of the cardiac left ventricle (LV). This task is performed using MR images to calculate the analytic cardiac parameter like end-systolic volume, end-diastolic volume, ejection fraction, and myocardial mass, respectively. These analytic parameters depend upon genuine delineation of epicardial, endocardial, papillary muscle, and trabeculations contours. In this paper, we propose an automatic segmentation method using the sum of absolute differences technique to localize the left ventricle. Blind morphological operations are proposed to segment and detect the LV contours of the epicardium and endocardium, automatically. We test the benchmark Sunny Brook dataset for evaluation of the proposed work. Contours of epicardium and endocardium are compared quantitatively to determine contour's accuracy and observe high matching values. Similarity or overlapping of an automatic examination to the given ground truth analysis by an expert are observed with high accuracy as with an index value of 91.30% . The proposed method for automatic segmentation gives better performance relative to existing techniques in terms of accuracy.

  19. Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy

    NARCIS (Netherlands)

    O.I.I. Soliman (Osama Ibrahim Ibrahim); D.A.M.J. Theuns (Dominic); M.L. Geleijnse (Marcel); A. Nemes (Attila); K. Caliskan (Kadir); W.B. Vletter (Wim); L.J.L.M. Jordaens (Luc); F.J. ten Cate (Folkert)

    2007-01-01

    textabstractAims: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) ≥60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). Methods and results

  20. Visualization of Uncertain Contour Trees

    DEFF Research Database (Denmark)

    Kraus, Martin

    2010-01-01

    Contour trees can represent the topology of large volume data sets in a relatively compact, discrete data structure. However, the resulting trees often contain many thousands of nodes; thus, many graph drawing techniques fail to produce satisfactory results. Therefore, several visualization methods...... were proposed recently for the visualization of contour trees. Unfortunately, none of these techniques is able to handle uncertain contour trees although any uncertainty of the volume data inevitably results in partially uncertain contour trees. In this work, we visualize uncertain contour trees...... by combining the contour trees of two morphologically filtered versions of a volume data set, which represent the range of uncertainty. These two contour trees are combined and visualized within a single image such that a range of potential contour trees is represented by the resulting visualization. Thus...

  1. Automated cardiopulmonary resuscitation using a load-distributing band external cardiac support device for in-hospital cardiac arrest: a single centre experience of AutoPulse-CPR.

    Science.gov (United States)

    Spiro, J R; White, S; Quinn, N; Gubran, C J; Ludman, P F; Townend, J N; Doshi, S N

    2015-02-01

    Poor quality cardiopulmonary resuscitation (CPR) predicts adverse outcome. During invasive cardiac procedures automated-CPR (A-CPR) may help maintain effective resuscitation. The use of A-CPR following in-hospital cardiac arrest (IHCA) remains poorly described. Firstly, we aimed to assess the efficiency of healthcare staff using A-CPR in a cardiac arrest scenario at baseline, following re-training and over time (Scenario-based training). Secondly, we studied our clinical experience of A-CPR at our institution over a 2-year period, with particular emphasis on the details of invasive cardiac procedures performed, problems encountered, resuscitation rates and in-hospital outcome (AutoPulse-CPR Registry). Scenario-based training: Forty healthcare professionals were assessed. At baseline, time-to-position device was slow (mean 59 (±24) s (range 15-96s)), with the majority (57%) unable to mode-switch. Following re-training time-to-position reduced (28 (±9) s, pCPR Registry: 285 patients suffered IHCA, 25 received A-CPR. Survival to hospital discharge following conventional CPR was 28/260 (11%) and 7/25 (28%) following A-CPR. A-CPR supported invasive procedures in 9 patients, 2 of whom had A-CPR dependant circulation during transfer to the catheter lab. A-CPR may provide excellent haemodynamic support and facilitate simultaneous invasive cardiac procedures. A significant learning curve exists when integrating A-CPR into clinical practice. Further studies are required to better define the role and effectiveness of A-CPR following IHCA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG.

    Science.gov (United States)

    van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G

    2015-01-01

    Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used

  3. Fairfax County Contours

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — This layer contains contours that were derived from the digital terrain model made up of irregularly spaced mass points and breaklines. The contours are 5 foot...

  4. Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study.

    Science.gov (United States)

    Fast, Martin F; Eiben, Björn; Menten, Martin J; Wetscherek, Andreas; Hawkes, David J; McClelland, Jamie R; Oelfke, Uwe

    2017-12-01

    Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA) lung cancer patients. Twenty-two cine MRI sequences were acquired using either a balanced steady-state free precession or a spoiled gradient echo imaging technique. Contours derived by the auto-contouring algorithms were compared against manual reference contours. A selection of eight image data sets was also used to assess the inter-observer delineation uncertainty. Algorithmically derived contours agreed well with the manual reference contours (median Dice similarity index: ⩾0.91). Multi-template matching and deformable image registration performed significantly better than feature-driven registration and the pulse-coupled neural network (PCNN). Neither MRI sequence nor image orientation was a conclusive predictor for algorithmic performance. Motion significantly degraded the performance of the PCNN. The inter-observer variability was of the same order of magnitude as the algorithmic performance. Auto-contouring of tumours on cine MRI is feasible in LA lung cancer patients. Despite large variations in implementation complexity, the different algorithms all have relatively similar performance. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  5. Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively.

    Science.gov (United States)

    Lahner, D; Kabon, B; Marschalek, C; Chiari, A; Pestel, G; Kaider, A; Fleischmann, E; Hetz, H

    2009-09-01

    Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fluid responsiveness as measured by the oesophageal Doppler. Patients undergoing major abdominal surgery received intraoperative fluid management guided by oesophageal Doppler monitoring. Fluid boluses of 250 ml each were administered in case of a decrease in corrected flow time (FTc) to 10%. The ability of SVV to predict fluid responsiveness was assessed by calculation of the area under the receiver operating characteristic (ROC) curve. Twenty patients received 67 fluid boluses. Fifty-two of the 67 fluid boluses administered resulted in fluid responsiveness. SVV achieved an area under the ROC curve of 0.512 [confidence interval (CI) 0.32-0.70]. A cut-off point for fluid responsiveness was found for SVV > or =8.5% (sensitivity: 77%; specificity: 43%; positive predictive value: 84%; and negative predictive value: 33%). This prospective, interventional observer-blinded study demonstrates that SVV obtained by APCO, using the FloTrac/Vigileo system, is not a reliable predictor of fluid responsiveness in the setting of major abdominal surgery.

  6. Improved approach to quantitative cardiac volumetrics using automatic thresholding and manual trimming: a cardiovascular MRI study.

    Science.gov (United States)

    Rayarao, Geetha; Biederman, Robert W W; Williams, Ronald B; Yamrozik, June A; Lombardi, Richard; Doyle, Mark

    2018-01-01

    To establish the clinical validity and accuracy of automatic thresholding and manual trimming (ATMT) by comparing the method with the conventional contouring method for in vivo cardiac volume measurements. CMR was performed on 40 subjects (30 patients and 10 controls) using steady-state free precession cine sequences with slices oriented in the short-axis and acquired contiguously from base to apex. Left ventricular (LV) volumes, end-diastolic volume, end-systolic volume, and stroke volume (SV) were obtained with ATMT and with the conventional contouring method. Additionally, SV was measured independently using CMR phase velocity mapping (PVM) of the aorta for validation. Three methods of calculating SV were compared by applying Bland-Altman analysis. The Bland-Altman standard deviation of variation (SD) and offset bias for LV SV for the three sets of data were: ATMT-PVM (7.65, [Formula: see text]), ATMT-contours (7.85, [Formula: see text]), and contour-PVM (11.01, 4.97), respectively. Equating the observed range to the error contribution of each approach, the error magnitude of ATMT:PVM:contours was in the ratio 1:2.4:2.5. Use of ATMT for measuring ventricular volumes accommodates trabeculae and papillary structures more intuitively than contemporary contouring methods. This results in lower variation when analyzing cardiac structure and function and consequently improved accuracy in assessing chamber volumes.

  7. Cardiac Rehabilitation: MedlinePlus Health Topic

    Science.gov (United States)

    ... in Spanish Electrocardiogram (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Cardiac Rehabilitation updates ... How to take your pulse Pulse Related Health Topics Heart Attack Heart Diseases How to Prevent Heart ...

  8. CONTOUR investigation launched

    Science.gov (United States)

    Showstack, Randy

    On 27 August, NASA Administrator Sean O'Keefe appointed a team to investigate the apparent loss of the Comet Nucleus Tour (CONTOUR) spacecraft, which stopped communicating with the mission control operations on 15 August.On that date, CONTOUR failed to communicate following the firing of its main engine that would take it out of its orbit around the Earth. Shortly afterwards, the mission team received telescope images from several observatories showing two objects traveling along the spacecraft's predicted path. Those objects could be CONTOUR, and part of the spacecraft that may have separated from it when the spacecraft's solid rocket motor fired.

  9. (Con)fusing contours

    NARCIS (Netherlands)

    Lier, R.J. van; Wit, T.C.J. de; Koning, A.R.

    2005-01-01

    We have created patterns in which illusory Kanizsa squares are positioned on top of a background grid of bars. When the illusory contours and physical contours are misaligned, the resulting percept appears to be rather confusing (van Lier et al, 2004 Perception 33 Supplement, 77). Observers often

  10. Pulse-driven magnetoimpedance sensor detection of cardiac magnetic activity.

    Directory of Open Access Journals (Sweden)

    Shinsuke Nakayama

    Full Text Available This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG. The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

  11. Evaluation of dose to cardiac structures during breast irradiation

    DEFF Research Database (Denmark)

    Aznar, M C; Korreman, S-S; Pedersen, A N

    2011-01-01

    delivered to the heart and the LAD in respiration-adapted radiotherapy of patients with left-sided breast cancer. METHODS: 24 patients referred for adjuvant radiotherapy after breast-conserving surgery for left-sided lymph node positive breast cancer were evaluated. The whole heart, the arch of the LAD...... and the whole LAD were contoured. The radiation doses to all three cardiac structures were evaluated. RESULTS: For 13 patients, the plans were acceptable based on the criteria set for all 3 contours. For seven patients, the volume of heart irradiated was well below the set clinical threshold whereas a high dose...

  12. Comparison of yoga and walking-exercise on cardiac time intervals as a measure of cardiac function in elderly with increased pulse pressure.

    Science.gov (United States)

    Patil, Satish Gurunathrao; Patil, Shankargouda S; Aithala, Manjunatha R; Das, Kusal Kanti

    Arterial aging along with increased blood pressure(BP) has become the major cardiovascular(CV) risk in elderly. The aim of the study was to compare the effects of yoga program and walking-exercise on cardiac function in elderly with increased pulse pressure (PP). An open label, parallel-group randomized controlled study design was adopted. Elderly individuals aged ≥60 years with PP≥60mmHg were recruited for the study. Yoga (study) group (n=30) was assigned for yoga training and walking (exercise) group (n=30) for walking with loosening practices for one hour in the morning for 6days in a week for 3 months. The outcome measures were cardiac time intervals derived from pulse wave analysis and ECG: resting heart rate (RHR), diastolic time(DT), ventricular ejection time(LVET), upstroke time(UT), ejection duration index (ED%), pre-ejection period (PEP), rate pressure product (RPP) and percentage of mean arterial pressure (%MAP). The mean within-yoga group change in RHR(bpm) was 4.41 (p=0.031), PD(ms): -50.29 (p=0.042), DT(ms): -49.04 (p=0.017), ED%: 2.107 (p=0.001), ES(mmHg/ms): 14.62 (p=0.118), ET(ms): -0.66 (p=0.903), UT(ms): -2.54 (p=0.676), PEP(ms): -1.25 (p=0.11) and %MAP: 2.08 (p=0.04). The mean within-control group change in HR (bpm) was 0.35 (p=0.887), PD (ms): 11.15(p=0.717), DT (ms): 11.3 (p=0.706), ED%: -0.101 (p=0.936), ES (mmHg/ms): 0.75 (p=0.926), ET(ms): 2.2 (p=0.721), UT(ms):4.7(p=455), PEP (ms): 2.1(p=0.11), %MAP: 0.65 (p=0.451). A significant difference between-group was found in RHR (p=0.036), PD (p=0.02), ED% (p=0.049), LVET (p=0.048), DT (p=0.02) and RPP (p=0.001). Yoga practice for 3 months showed a significant improvement in diastolic function with a minimal change in systolic function. Yoga is more effective than walking in improving cardiac function in elderly with high PP. Copyright © 2017 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  13. Contoured-gap coaxial guns for imploding plasma liner experiments

    Science.gov (United States)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  14. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry.

    Science.gov (United States)

    Hoffmann, Esther M; Grus, Franz-H; Pfeiffer, Norbert

    2004-03-23

    The new Ocular Dynamic Contour Tonometer (DCT), investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland) allows simultaneous recording of intraocular pressure (IOP) and ocular pulse amplitude (OPA). It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens,a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland). Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens. No difference (P = 0.09) was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg) and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg). The IOP values of SmartLens (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg) were significantly higher (P = 0.0008) both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg) were significantly lower (P = 0.0003) than those obtained by SmartLens (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg). DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens (contact lens tonometry) gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.

  15. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  16. Tagged Vector Contour (TVC)

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Tagged Vector Contour (TVC) dataset consists of digitized contours from the 7.5 minute topographic quadrangle maps. Coverage for the state is incomplete....

  17. Ocean Sediment Thickness Contours

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean sediment thickness contours in 200 meter intervals for water depths ranging from 0 - 18,000 meters. These contours were derived from a global sediment...

  18. 21 CFR 870.5550 - External transcutaneous cardiac pacemaker (noninvasive).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External transcutaneous cardiac pacemaker... § 870.5550 External transcutaneous cardiac pacemaker (noninvasive). (a) Identification. An external transcutaneous cardiac pacemaker (noninvasive) is a device used to supply a periodic electrical pulse intended to...

  19. Automated consensus contour building for prostate MRI.

    Science.gov (United States)

    Khalvati, Farzad

    2014-01-01

    Inter-observer variability is the lack of agreement among clinicians in contouring a given organ or tumour in a medical image. The variability in medical image contouring is a source of uncertainty in radiation treatment planning. Consensus contour of a given case, which was proposed to reduce the variability, is generated by combining the manually generated contours of several clinicians. However, having access to several clinicians (e.g., radiation oncologists) to generate a consensus contour for one patient is costly. This paper presents an algorithm that automatically generates a consensus contour for a given case using the atlases of different clinicians. The algorithm was applied to prostate MR images of 15 patients manually contoured by 5 clinicians. The automatic consensus contours were compared to manual consensus contours where a median Dice similarity coefficient (DSC) of 88% was achieved.

  20. Pitch contour impairment in congenital amusia: New insights from the Self-paced Audio-visual Contour Task (SACT).

    Science.gov (United States)

    Lu, Xuejing; Sun, Yanan; Ho, Hao Tam; Thompson, William Forde

    2017-01-01

    Individuals with congenital amusia usually exhibit impairments in melodic contour processing when asked to compare pairs of melodies that may or may not be identical to one another. However, it is unclear whether the impairment observed in contour processing is caused by an impairment of pitch discrimination, or is a consequence of poor pitch memory. To help resolve this ambiguity, we designed a novel Self-paced Audio-visual Contour Task (SACT) that evaluates sensitivity to contour while placing minimal burden on memory. In this task, participants control the pace of an auditory contour that is simultaneously accompanied by a visual contour, and they are asked to judge whether the two contours are congruent or incongruent. In Experiment 1, melodic contours varying in pitch were presented with a series of dots that varied in spatial height. Amusics exhibited reduced sensitivity to audio-visual congruency in comparison to control participants. To exclude the possibility that the impairment arises from a general deficit in cross-modal mapping, Experiment 2 examined sensitivity to cross-modal mapping for two other auditory dimensions: timbral brightness and loudness. Amusics and controls were significantly more sensitive to large than small contour changes, and to changes in loudness than changes in timbre. However, there were no group differences in cross-modal mapping, suggesting that individuals with congenital amusia can comprehend spatial representations of acoustic information. Taken together, the findings indicate that pitch contour processing in congenital amusia remains impaired even when pitch memory is relatively unburdened.

  1. Pitch contour impairment in congenital amusia: New insights from the Self-paced Audio-visual Contour Task (SACT.

    Directory of Open Access Journals (Sweden)

    Xuejing Lu

    Full Text Available Individuals with congenital amusia usually exhibit impairments in melodic contour processing when asked to compare pairs of melodies that may or may not be identical to one another. However, it is unclear whether the impairment observed in contour processing is caused by an impairment of pitch discrimination, or is a consequence of poor pitch memory. To help resolve this ambiguity, we designed a novel Self-paced Audio-visual Contour Task (SACT that evaluates sensitivity to contour while placing minimal burden on memory. In this task, participants control the pace of an auditory contour that is simultaneously accompanied by a visual contour, and they are asked to judge whether the two contours are congruent or incongruent. In Experiment 1, melodic contours varying in pitch were presented with a series of dots that varied in spatial height. Amusics exhibited reduced sensitivity to audio-visual congruency in comparison to control participants. To exclude the possibility that the impairment arises from a general deficit in cross-modal mapping, Experiment 2 examined sensitivity to cross-modal mapping for two other auditory dimensions: timbral brightness and loudness. Amusics and controls were significantly more sensitive to large than small contour changes, and to changes in loudness than changes in timbre. However, there were no group differences in cross-modal mapping, suggesting that individuals with congenital amusia can comprehend spatial representations of acoustic information. Taken together, the findings indicate that pitch contour processing in congenital amusia remains impaired even when pitch memory is relatively unburdened.

  2. Digital extraction of interference fringe contours

    International Nuclear Information System (INIS)

    Mastin, G.A.; Ghiglia, D.C.

    1985-01-01

    Two basic techniques for extracting interferogram contours have been discussed. The first is a global contour extracton technique based on the fast Fourier transform. The second extracts individual contours with a thinning algorithm using logical neighborhood transformations

  3. Image Interpolation with Geometric Contour Stencils

    Directory of Open Access Journals (Sweden)

    Pascal Getreuer

    2011-09-01

    Full Text Available We consider the image interpolation problem where given an image vm,n with uniformly-sampled pixels vm,n and point spread function h, the goal is to find function u(x,y satisfying vm,n = (h*u(m,n for all m,n in Z. This article improves upon the IPOL article Image Interpolation with Contour Stencils. In the previous work, contour stencils are used to estimate the image contours locally as short line segments. This article begins with a continuous formulation of total variation integrated over a collection of curves and defines contour stencils as a consistent discretization. This discretization is more reliable than the previous approach and can effectively distinguish contours that are locally shaped like lines, curves, corners, and circles. These improved contour stencils sense more of the geometry in the image. Interpolation is performed using an extension of the method described in the previous article. Using the improved contour stencils, there is an increase in image quality while maintaining similar computational efficiency.

  4. Spectrally accurate contour dynamics

    International Nuclear Information System (INIS)

    Van Buskirk, R.D.; Marcus, P.S.

    1994-01-01

    We present an exponentially accurate boundary integral method for calculation the equilibria and dynamics of piece-wise constant distributions of potential vorticity. The method represents contours of potential vorticity as a spectral sum and solves the Biot-Savart equation for the velocity by spectrally evaluating a desingularized contour integral. We use the technique in both an initial-value code and a newton continuation method. Our methods are tested by comparing the numerical solutions with known analytic results, and it is shown that for the same amount of computational work our spectral methods are more accurate than other contour dynamics methods currently in use

  5. The influence of automation on tumor contouring

    NARCIS (Netherlands)

    Aselmaa, A.; van Herk, Marcel; Song, Y.; Goossens, R.H.M.; Laprie, Anne

    2017-01-01

    Fully or semi-automatic contouring tools are increasingly being used in the tumor contouring task for radiotherapy. While the fully automatic contouring tools have not reached sufficient efficiency, the semi-automatic contouring tools balance more effectively between the human interaction and

  6. Enhancement of Afterimage Colors by Surrounding Contours

    Directory of Open Access Journals (Sweden)

    Takao Sato

    2011-05-01

    Full Text Available Presenting luminance contours surrounding the adapted areas in test phase enhances color afterimages in both duration and color appearance. The presence of surrounding contour is crucial to some color phenomenon such as van Lier's afterimage, but the contour-effect itself has not been seriously examined. In this paper, we compared the contour-effect to color afterimages and to actually colored patches to examine the nature of color information subserving color-aftereffect. In the experiment, observers were adapted for 1 sec to a small colored square (red, green, yellow, or blue presented on a gray background. Then, a test field either with or without surrounding contour was presented. Observers matched the color of a test-patch located near the afterimage to the color of afterimage. It was found that the saturation of negative afterimage was almost doubled by the presence of surrounding contours. There was no effect of luminance contrast or polarity of contours. In contrast, no enhancement of saturation by surrounding contours was observed for actually colored patches even though the colors of patches were equalized to that of afterimage without contours. This dissociation in the contour-effect demonstrates the crucial difference between the color information for aftereffects and for ordinary bottom-up color perception.

  7. Anatomical contouring variability in thoracic organs at risk

    Energy Technology Data Exchange (ETDEWEB)

    McCall, Ross, E-mail: rmccall86@gmail.com [Medical Dosimetry Program, University of Wisconsin, La Crosse, WI (United States); MacLennan, Grayden; Taylor, Matthew; Lenards, Nishele [Medical Dosimetry Program, University of Wisconsin, La Crosse, WI (United States); Nelms, Benjamin E. [Canis Lupus LLC, Madison, WI (United States); Koshy, Matthew; Lemons, Jeffrey [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL (United States); Hunzeker, Ashley [Medical Dosimetry Program, University of Wisconsin, La Crosse, WI (United States)

    2016-01-01

    The purpose of this study was to determine whether contouring thoracic organs at risk was consistent among medical dosimetrists and to identify how trends in dosimetrist's education and experience affected contouring accuracy. Qualitative and quantitative methods were used to contextualize the raw data that were obtained. A total of 3 different computed tomography (CT) data sets were provided to medical dosimetrists (N = 13) across 5 different institutions. The medical dosimetrists were directed to contour the lungs, heart, spinal cord, and esophagus. The medical dosimetrists were instructed to contour in line with their institutional standards and were allowed to use any contouring tool or technique that they would traditionally use. The contours from each medical dosimetrist were evaluated against “gold standard” contours drawn and validated by 2 radiation oncology physicians. The dosimetrist-derived contours were evaluated against the gold standard using both a Dice coefficient method and a penalty-based metric scoring system. A short survey was also completed by each medical dosimetrist to evaluate their individual contouring experience. There was no significant variation in the contouring consistency of the lungs and spinal cord. Intradosimetrist contouring was consistent for those who contoured the esophagus and heart correctly; however, medical dosimetrists with a poor metric score showed erratic and inconsistent methods of contouring.

  8. Cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Andreja Möller Petrun

    2014-02-01

    Full Text Available In recent years, developments in the measuring of cardiac output and other haemodynamic variables are focused on the so-called minimally invasive methods. The aim of these methods is to simplify the management of high-risk and haemodynamically unstable patients. Due to the need of invasive approach and the possibility of serious complications the use of pulmonary artery catheter has decreased. This article describes the methods for measuring cardiac output, which are based on volume measurement (Fick method, indicator dilution method, pulse wave analysis, Doppler effect, and electrical bioimpedance.

  9. Evaluation of a new pulse oximeter sensor.

    Science.gov (United States)

    Fernandez, Marco; Burns, Kathy; Calhoun, Beverly; George, Saramma; Martin, Beverly; Weaver, Chris

    2007-03-01

    A new forehead noninvasive oxygen saturation sensor may improve signal quality in patients with low cardiac index. To examine agreement between oxygen saturation values obtained by using digit-based and forehead pulse oximeters with arterial oxygen saturation in patients with low cardiac index. A method-comparison study was used to examine the agreement between 2 different pulse oximeters and arterial oxygen saturation in patients with low cardiac index. Readings were obtained from a finger and a forehead sensor and by analysis of a blood sample. Bias, precision, and root mean square differences were calculated for the digit and forehead sensors. Differences in bias and precision between the 2 noninvasive devices were evaluated with a t test (level of significance P<.05). Nineteen patients with low cardiac index (calculated as cardiac output in liters per minute divided by body surface area in square meters; mean 1.98, SD 0.34) were studied for a total of 54 sampling periods. Mean (SD) oxygen saturations were 97% (2.4) for blood samples, 96% (3.2) for the finger sensor, and 97% (2.8) for the forehead sensor. By Bland Altman analysis, bias +/- precision was -1.16 +/- 1.62% for the digit sensor and -0.36 +/- 1.74% for the forehead sensor; root mean square differences were 1.93% and 1.70%, respectively. Bias and precision differed significantly between the 2 devices; the forehead sensor differed less from the blood sample. In patients with low cardiac index, the forehead sensor was better than the digit sensor for pulse oximetry.

  10. An improved spatial contour tree constructed method

    Science.gov (United States)

    Zheng, Yi; Zhang, Ling; Guilbert, Eric; Long, Yi

    2018-05-01

    Contours are important data to delineate the landform on a map. A contour tree provides an object-oriented description of landforms and can be used to enrich the topological information. The traditional contour tree is used to store topological relationships between contours in a hierarchical structure and allows for the identification of eminences and depressions as sets of nested contours. This research proposes an improved contour tree so-called spatial contour tree that contains not only the topological but also the geometric information. It can be regarded as a terrain skeleton in 3-dimention, and it is established based on the spatial nodes of contours which have the latitude, longitude and elevation information. The spatial contour tree is built by connecting spatial nodes from low to high elevation for a positive landform, and from high to low elevation for a negative landform to form a hierarchical structure. The connection between two spatial nodes can provide the real distance and direction as a Euclidean vector in 3-dimention. In this paper, the construction method is tested in the experiment, and the results are discussed. The proposed hierarchical structure is in 3-demintion and can show the skeleton inside a terrain. The structure, where all nodes have geo-information, can be used to distinguish different landforms and applied for contour generalization with consideration of geographic characteristics.

  11. Automatic re-contouring in 4D radiotherapy

    International Nuclear Information System (INIS)

    Lu, Weiguo; Olivera, Gustavo H; Chen, Quan; Chen, Ming-Li; Ruchala, Kenneth J

    2006-01-01

    Delineating regions of interest (ROIs) on each phase of four-dimensional (4D) computed tomography (CT) images is an essential step for 4D radiotherapy. The requirement of manual phase-by-phase contouring prohibits the routine use of 4D radiotherapy. This paper develops an automatic re-contouring algorithm that combines techniques of deformable registration and surface construction. ROIs are manually contoured slice-by-slice in the reference phase image. A reference surface is constructed based on these reference contours using a triangulated surface construction technique. The deformable registration technique provides the voxel-to-voxel mapping between the reference phase and the test phase. The vertices of the reference surface are displaced in accordance with the deformation map, resulting in a deformed surface. The new contours are reconstructed by cutting the deformed surface slice-by-slice along the transversal, sagittal or coronal direction. Since both the inputs and outputs of our automatic re-contouring algorithm are contours, it is relatively easy to cope with any treatment planning system. We tested our automatic re-contouring algorithm using a deformable phantom and 4D CT images of six lung cancer patients. The proposed algorithm is validated by visual inspections and quantitative comparisons of the automatic re-contours with both the gold standard segmentations and the manual contours. Based on the automatic delineated ROIs, changes of tumour and sensitive structures during respiration are quantitatively analysed. This algorithm could also be used to re-contour daily images for treatment evaluation and adaptive radiotherapy

  12. Pulse pressure and nocturnal fall in blood pressure are predictors of vascular, cardiac and renal target organ damage in hypertensive patients (LOD-RISK study).

    Science.gov (United States)

    García-Ortiz, Luis; Gómez-Marcos, Manuel A; Martín-Moreiras, Javier; González-Elena, Luis J; Recio-Rodriguez, Jose I; Castaño-Sánchez, Yolanda; Grandes, Gonzalo; Martínez-Salgado, Carlos

    2009-08-01

    To analyse the relationship between various parameters derived from ambulatory blood pressure monitoring (ABPM) and vascular, cardiac and renal target organ damage. A cross-sectional, descriptive study. It included 353 patients with short-term or recently diagnosed hypertension. ABPM, carotid intima-media thickness (IMT), Cornell voltage-duration product (Cornell VDP), glomerular filtration rate and albumin/creatinine ratio to assess vascular, cardiac and renal damage. Two hundred and twenty-three patients (63.2%) were males, aged 56.12+/-11.21 years. The nocturnal fall in blood pressure was 11.33+/-8.41, with a dipper pattern in 49.0% (173), nondipper in 30.3% (107), extreme dipper in 12.7% (45) and riser in 7.9% (28). The IMT was lower in the extreme dipper (0.716+/-0.096 mm) and better in the riser pattern (0.794+/-0.122 mm) (P<0.05). The Cornell VDP and albumin/creatinine ratio were higher in the riser pattern (1818.94+/-1798.63 mm/ms and 140.78+/-366.38 mg/g, respectively) than in the other patterns. In the multivariate analysis after adjusting for age, sex and antihypertensive treatment, with IMT as dependent variable the 24-h pulse pressure (beta = 0.003), with Cornell VDP the rest pulse pressure (beta = 12.04), and with the albumin/creatinine ratio the percentage of nocturnal fall in systolic blood pressure (beta = -3.59), the rest heart rate (beta = 1.83) and the standard deviation of 24-h systolic blood pressure (beta = 5.30) remain within the equation. The estimated pulse pressure with ABPM is a predictor of vascular and cardiac organ damage. The nocturnal fall and the standard deviation in 24-h systolic blood pressure measured with the ABPM is a predictor of renal damage.

  13. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

    Directory of Open Access Journals (Sweden)

    Grus Franz-H

    2004-03-01

    Full Text Available Abstract Background The new Ocular Dynamic Contour Tonometer (DCT, investigational device supplied by SMT (Swiss Microtechnology AG, Switzerland allows simultaneous recording of intraocular pressure (IOP and ocular pulse amplitude (OPA. It was the aim of this study to compare the IOP results of this new device with Goldmann tonometry. Furthermore, IOP and OPA measured with the new slitlamp-mounted DCT were compared to the IOP and OPA measured with the hand-held SmartLens®, a gonioscopic contact lens tonometer (ODC Ophthalmic Development Company AG, Switzerland. Methods Nineteen healthy subjects were included in this study. IOP was determined by three consecutive measurements with each of the DCT, SmartLens®, and Goldmann tonometer. Furthermore, OPA was measured three times consecutively by DCT and SmartLens®. Results No difference (P = 0.09 was found between the IOP values by means of DCT (mean: 16.6 mm Hg, median: 15.33 mm Hg, SD: +/- 4.04 mm Hg and Goldmann tonometry (mean: 16.17 mm Hg, median: 15.33 mm Hg, SD: +/- 4.03 mm Hg. The IOP values of SmartLens® (mean: 20.25 mm Hg, median: 19.00 mm Hg, SD: +/- 4.96 mm Hg were significantly higher (P = 0.0008 both from Goldmann tonometry and DCT. The OPA values of the DCT (mean: 3.08 mm Hg, SD: +/- 0.92 mm Hg were significantly lower (P = 0.0003 than those obtained by SmartLens® (mean: 3.92 mm Hg, SD: +/- 0.83 mm Hg. Conclusions DCT was equivalent to Goldmann applanation tonometry in measurement of IOP in a small group of normal subjects. In contrast, SmartLens® (contact lens tonometry gave IOP readings that were significantly higher compared with Goldmann applanation tonometer readings. Both devices, DCT and SmartLens® provide the measurement of OPA which could be helpful e.g. for the management of glaucoma.

  14. Drawing Contour Trees in the Plane.

    Science.gov (United States)

    Heine, C; Schneider, D; Carr, Hamish; Scheuermann, G

    2011-11-01

    The contour tree compactly describes scalar field topology. From the viewpoint of graph drawing, it is a tree with attributes at vertices and optionally on edges. Standard tree drawing algorithms emphasize structural properties of the tree and neglect the attributes. Applying known techniques to convey this information proves hard and sometimes even impossible. We present several adaptions of popular graph drawing approaches to the problem of contour tree drawing and evaluate them. We identify five esthetic criteria for drawing contour trees and present a novel algorithm for drawing contour trees in the plane that satisfies four of these criteria. Our implementation is fast and effective for contour tree sizes usually used in interactive systems (around 100 branches) and also produces readable pictures for larger trees, as is shown for an 800 branch example.

  15. Visualizing Contour Trees within Histograms

    DEFF Research Database (Denmark)

    Kraus, Martin

    2010-01-01

    Many of the topological features of the isosurfaces of a scalar volume field can be compactly represented by its contour tree. Unfortunately, the contour trees of most real-world volume data sets are too complex to be visualized by dot-and-line diagrams. Therefore, we propose a new visualization...... that is suitable for large contour trees and efficiently conveys the topological structure of the most important isosurface components. This visualization is integrated into a histogram of the volume data; thus, it offers strictly more information than a traditional histogram. We present algorithms...... to automatically compute the graph layout and to calculate appropriate approximations of the contour tree and the surface area of the relevant isosurface components. The benefits of this new visualization are demonstrated with the help of several publicly available volume data sets....

  16. Orientation-crowding within contours.

    Science.gov (United States)

    Glen, James C; Dakin, Steven C

    2013-07-15

    We examined how crowding (the breakdown of object recognition in the periphery caused by interference from "clutter") depends on the global arrangement of target and distracting flanker elements. Specifically we probed orientation discrimination using a near-vertical target Gabor flanked by two vertical distractor Gabors (one above and one below the target). By applying variable (opposite-sign) horizontal offsets to the positions of the two flankers we arranged the elements so that on some trials they formed contours with the target and on others they did not. While the presence of flankers generally elevated orientation discrimination thresholds for the target we observe maximal crowding not when flanker and targets were co-aligned but when a small spatial offset was applied to flanker location, so that contours formed between flanker and targets only when the target orientation was cued. We also report that observers' orientation judgments are biased, with target orientation appearing either attracted or repulsed by the global/contour orientation. A second experiment reveals that the sign of this effect is dependent both on observer and on eccentricity. In general, the magnitude of repulsion is reduced with eccentricity but whether this becomes attraction (of element orientation to contour orientation) is dependent on observer. We note however that across observers and eccentricities, the magnitude of repulsion correlates positively with the amount of release from crowding observed with co-aligned targets and flankers, supporting the notion of fluctuating bias as the basis for elevated crowding within contours.

  17. Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio; Sato, Masato; Sakakibara, Yuzuru; Sakae, Takeji; Hayashi, Yasutaka; Nakayama, Hidetsugu; Tsuboi, Koji; Fukumitsu, Nobuyoshi; Kanemoto, Ayae; Hashimoto, Takayuki; Tokuuye, Koichi

    2008-01-01

    Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT

  18. Development of a contour meter

    International Nuclear Information System (INIS)

    Andrada C, F.A.; Sanz, D.E.

    2006-01-01

    The dosimetric calculation in patients that receive radiotherapy treatment it requires the one knowledge of the geometry of some anatomical portions, which differs from a patient to another. Making reference to the specific case of mammary neoplasia, one of the measurements that is carried out on the patient is the acquisition of the contour of the breast, which is determined from a point marked on the breastbone until another point marked on the lateral of the thorax, below the armpit, with the patient located in the irradiation position. This measurement is carried out with the help of a mechanical contour meter that is a device conformed by a series of wires with a polymeric coating, which support on the breast of the patient and it reproduces its form. Then it is transported in the more careful possible form on a paper and the contour is traced with a tracer one. The geometric error associated to this procedure is of ±1 cm, which is sensitive of being reduced. The present work finds its motivation in the patient's radiological protection radiotherapy. The maximum error in dose allowed in radiotherapeutic treatments is 5%. It would be increase the precision and with it to optimize the treatment received by the patient, reducing the error in the acquisition process of the mammary contour. With this objective, a digital device is designed whose operation is based in the application of a spatial transformation on a picture of the mammary contour, which corrects the geometric distortion introduced in the process of the photographic acquisition. An algorithm that allows to obtain a front image (without distortion) of the plane of the contour was developed. A software tool especially developed carries out the processing of the digital images. The maximum geometric error detected in the validation process is 2 mm located on a small portion of the contour. (Author)

  19. A Method for Denoising Image Contours

    Directory of Open Access Journals (Sweden)

    Ovidiu COSMA

    2017-12-01

    Full Text Available The edge detection techniques have to compromise between sensitivity and noise. In order for the main contours to be uninterrupted, the level of sensitivity has to be raised, which however has the negative effect of producing a multitude of insignificant contours (noise. This article proposes a method of removing this noise, which acts directly on the binary representation of the image contours.

  20. Development of a CONTOUR-METER

    International Nuclear Information System (INIS)

    Andrada Contardi, F.A.

    2004-01-01

    Dose calculation in patients undergoing radiotherapy treatments requires the knowledge of their anatomical geometry.Making reference to the specific case of breast cancer, one of the measurement that are made on the patients is the acquisition of the breast's contour, determined in an axial plane from a point marked on the breastbone until another point marked on the thorax side under the armpit.This measurement is normally made with a mechanic contour-meter: a device formed by a series of plastic-covered wires designed to be applied on the patient's skin copying the breast contour after it deformation.The geometrical error associated with this procedure is ± 1 cm. The precision of the dose calculation could be increased acquiring a breast contour more accurate.This objective was achieved developing a method based on breast images from a digital camera.The algorithms to obtain an axial-plane image of the contour from digital photographs taken from arbitrary positions were developed.A geometric transformation is applied to the photograph to correct for perspective distortions, obtaining a frontal - undistorted image (axial-plane image).A software tool to make all the image processing was developed under MatLab.The maximum geometrical error detected during the validation of the process was 2 mm [es

  1. Contours - MO 2012 Greene County 5ft Contours (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — 5ft cartographic contour file for Greene County, Missouri. This file was created using the elevation data from the 2011 LiDAR flight. It includes indexes for 10, 25,...

  2. Active contour segmentation in dynamic medical imaging: application to nuclear cardiology

    International Nuclear Information System (INIS)

    Debreuve, Eric

    2000-01-01

    In emission imaging, nuclear medicine provides functional information about the organ of interest. In transmission imaging, it provides anatomical information whose goal may be the correction of physical phenomena that corrupt emission images. With both emission and transmission images, it is useful to know how to extract, either automatically or semi-automatically, the organs of interest and the body outline in the case of a large field of view. This is the aim of segmentation. We developed two active contour segmentation methods. They were implemented using level sets. The key point is the evolution velocity definition. First, we were interested in static transmission imaging of the thorax. The evolution velocity was heuristically defined and depended only on the acquired projections. The segmented transmission map was computed w/o reconstruction and could be advantageously used for attenuation correction. Then, we studied the segmentation of cardiac gated sequences. The developed space-time segmentation method results from the minimization of a variational criterion which takes into account the whole sequence. The computed segmentation could be used for calculating physiological parameters. As an illustration, we computed the ejection fraction. Finally, we exploited some level set properties to develop a non-rigid, non-parametric, and geometric registration method. We applied it for kinetic compensation of cardiac gated sequences. The registered images were then added together providing an image with noise characteristics similar to a cardiac static image but w/o motion-induced blurring. (author)

  3. Kredsløbsmonitorering med lithium dilution cardiac output-systemet

    DEFF Research Database (Denmark)

    Christiansen, Christian; Hostrup, Anette; Tønnesen, Else

    2008-01-01

    The lithium dilution cardiac output (LiDCO) system measures cardiac output beat-to-beat with high precision. The system is based on an arterial pulse power analysis which is calibrated every eight hours with a small non-pharmacological dose of lithium. The system is minimally invasive; it requires...

  4. Convolutional neural network regression for short-axis left ventricle segmentation in cardiac cine MR sequences.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; McLaughlin, Robert A

    2017-07-01

    Automated left ventricular (LV) segmentation is crucial for efficient quantification of cardiac function and morphology to aid subsequent management of cardiac pathologies. In this paper, we parameterize the complete (all short axis slices and phases) LV segmentation task in terms of the radial distances between the LV centerpoint and the endo- and epicardial contours in polar space. We then utilize convolutional neural network regression to infer these parameters. Utilizing parameter regression, as opposed to conventional pixel classification, allows the network to inherently reflect domain-specific physical constraints. We have benchmarked our approach primarily against the publicly-available left ventricle segmentation challenge (LVSC) dataset, which consists of 100 training and 100 validation cardiac MRI cases representing a heterogeneous mix of cardiac pathologies and imaging parameters across multiple centers. Our approach attained a .77 Jaccard index, which is the highest published overall result in comparison to other automated algorithms. To test general applicability, we also evaluated against the Kaggle Second Annual Data Science Bowl, where the evaluation metric was the indirect clinical measures of LV volume rather than direct myocardial contours. Our approach attained a Continuous Ranked Probability Score (CRPS) of .0124, which would have ranked tenth in the original challenge. With this we demonstrate the effectiveness of convolutional neural network regression paired with domain-specific features in clinical segmentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Contributions of pitch contour, tonality, rhythm, and meter to melodic similarity.

    Science.gov (United States)

    Prince, Jon B

    2014-12-01

    The identity of a melody resides in its sequence of pitches and durations, both of which exhibit surface details as well as structural properties. In this study, pitch contour (pattern of ups and downs) served as pitch surface information, and tonality (musical key) as pitch structure; in the temporal dimension, surface information was the ordinal duration ratios of adjacent notes (rhythm), and meter (beat, or pulse) comprised the structure. Factorially manipulating the preservation or alteration of all of these forms of information in 17 novel melodies (typifying Western music) enabled measuring their effect on perceived melodic similarity. In Experiment 1, 34 participants (varied musical training) rated the perceived similarity of melody pairs transposed to new starting pitches. Rhythm was the largest contributor to perceived similarity, then contour, meter, and tonality. Experiment 2 used the same melodies but varied the tempo within a pair, and added a prefix of 3 chords, which oriented the listener to the starting pitch and tempo before the melody began. Now contour was the strongest influence on similarity ratings, followed by tonality, and then rhythm; meter was not significant. Overall, surface features influenced perceived similarity more than structural, but both had observable effects. The primary theoretical advances in melodic similarity research are that (a) the relative emphasis on pitch and temporal factors is flexible; (b) pitch and time functioned independently when factorially manipulated, regardless of which dimension is more influential; and (c) interactions between surface and structural information were unreliable and never occurred between dimensions. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  6. Pancreatic gross tumor volume contouring on computed tomography (CT) compared with magnetic resonance imaging (MRI): Results of an international contouring conference.

    Science.gov (United States)

    Hall, William A; Heerkens, Hanne D; Paulson, Eric S; Meijer, Gert J; Kotte, Alexis N; Knechtges, Paul; Parikh, Parag J; Bassetti, Michael F; Lee, Percy; Aitken, Katharine L; Palta, Manisha; Myrehaug, Sten; Koay, Eugene J; Portelance, Lorraine; Ben-Josef, Edgar; Erickson, Beth A

    Accurate identification of the gross tumor volume (GTV) in pancreatic adenocarcinoma is challenging. We sought to understand differences in GTV delineation using pancreatic computed tomography (CT) compared with magnetic resonance imaging (MRI). Twelve attending radiation oncologists were convened for an international contouring symposium. All participants had a clinical and research interest in pancreatic adenocarcinoma. CT and MRI scans from 3 pancreatic cases were used for contouring. CT and MRI GTVs were analyzed and compared. Interobserver variability was compared using Dice's similarity coefficient (DSC), Hausdorff distances, and Jaccard indices. Mann-Whitney tests were used to check for significant differences. Consensus contours on CT and MRI scans and constructed count maps were used to visualize the agreement. Agreement regarding the optimal method to determine GTV definition using MRI was reached. Six contour sets (3 from CT and 3 from MRI) were obtained and compared for each observer, totaling 72 contour sets. The mean volume of contours on CT was significantly larger at 57.48 mL compared with a mean of 45.76 mL on MRI, P = .011. The standard deviation obtained from the CT contours was significantly larger than the standard deviation from the MRI contours (P = .027). The mean DSC was 0.73 for the CT and 0.72 for the MRI (P = .889). The conformity index measurement was similar for CT and MRI (P = .58). Count maps were created to highlight differences in the contours from CT and MRI. Using MRI as a primary image set to define a pancreatic adenocarcinoma GTV resulted in smaller contours compared with CT. No differences in DSC or the conformity index were seen between MRI and CT. A stepwise method is recommended as an approach to contour a pancreatic GTV using MRI. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  7. Sensitivity Analysis of Vagus Nerve Stimulation Parameters on Acute Cardiac Autonomic Responses: Chronotropic, Inotropic and Dromotropic Effects.

    Directory of Open Access Journals (Sweden)

    David Ojeda

    Full Text Available Although the therapeutic effects of Vagus Nerve Stimulation (VNS have been recognized in pre-clinical and pilot clinical studies, the effect of different stimulation configurations on the cardiovascular response is still an open question, especially in the case of VNS delivered synchronously with cardiac activity. In this paper, we propose a formal mathematical methodology to analyze the acute cardiac response to different VNS configurations, jointly considering the chronotropic, dromotropic and inotropic cardiac effects. A latin hypercube sampling method was chosen to design a uniform experimental plan, composed of 75 different VNS configurations, with different values for the main parameters (current amplitude, number of delivered pulses, pulse width, interpulse period and the delay between the detected cardiac event and VNS onset. These VNS configurations were applied to 6 healthy, anesthetized sheep, while acquiring the associated cardiovascular response. Unobserved VNS configurations were estimated using a Gaussian process regression (GPR model. In order to quantitatively analyze the effect of each parameter and their combinations on the cardiac response, the Sobol sensitivity method was applied to the obtained GPR model and inter-individual sensitivity markers were estimated using a bootstrap approach. Results highlight the dominant effect of pulse current, pulse width and number of pulses, which explain respectively 49.4%, 19.7% and 6.0% of the mean global cardiovascular variability provoked by VNS. More interestingly, results also quantify the effect of the interactions between VNS parameters. In particular, the interactions between current and pulse width provoke higher cardiac effects than the changes on the number of pulses alone (between 6 and 25% of the variability. Although the sensitivity of individual VNS parameters seems similar for chronotropic, dromotropic and inotropic responses, the interacting effects of VNS parameters

  8. A cognitive evaluation procedure for contour based shape descriptors

    NARCIS (Netherlands)

    Ghosh, Anarta; Petkov, Nicolai

    2005-01-01

    Present image processing algorithms are unable to extract a neat and closed contour of an object of interest from a natural image. Advanced contour detection algorithms extract the contour of an object of interest from a natural scene with a side effect of depletion of the contour. Hence in order to

  9. A comparison of left ventricular mass between two-dimensional echocardiography, using fundamental and tissue harmonic imaging, and cardiac MRI in patients with hypertension

    International Nuclear Information System (INIS)

    Alfakih, Khaled; Bloomer, Tim; Bainbridge, Samantha; Bainbridge, Gavin; Ridgway, John; Williams, Gordon; Sivananthan, Mohan

    2004-01-01

    Purpose: To compare left ventricular mass (LVM) as measured by two-dimensional (2D) echocardiography using two different calculation methods: truncated ellipse (TE) and area length (AL), in both fundamental and tissue harmonic imaging frequencies, to LVM as measured by, the current gold standard, cardiac magnetic resonance imaging (MRI). Turbo gradient echo (TGE) pulse sequence was utilized for MRI. Materials and methods: Thirty-two subjects with history of hypertension were recruited. The images were acquired, contours were traced and the LVM was calculated for all four different echocardiography methods as well as for the cardiac MRI method. The intra-observer variabilities were calculated. The four different echocardiography methods were compared to cardiac MRI using the method described by Bland and Altman. Results: Twenty-five subjects had adequate paired data sets. The mean LVM as measured by cardiac MRI was 162±55 g and for the four different echocardiography methods were: fundamental AL 165±55 g, harmonic AL 168±53 g, fundamental TE 148±50 g, harmonic TE 149±45 g. The intra-observer variability for cardiac MRI method, expressed as bias ± 1 standard deviation of the difference (S.D.D.), was 2.3±9.2 g and for the four different echocardiography methods were: fundamental TE 0.4±26.8 g, fundamental AL 0.6±27.0 g, harmonic TE 6.7±21.8 g, harmonic AL 6.4±22.9 g. The mean LVM for the AL method was closest to the cardiac MRI technique, while TE underestimated LVM. The 95% limits of agreement were consistently wide for all the 2D echocardiography modalities when compared with the cardiac MRI technique. Conclusion: The intra-observer variability in measurements of 2D echocardiographic LVM, together with the wide limits of agreement when compared to the gold standard (cardiac MRI) are sufficiently large to make serial estimates of LVM, of single patients or small groups of subjects, by 2D echocardiography, unreliable

  10. A Biologically Motivated Multiresolution Approach to Contour Detection

    Directory of Open Access Journals (Sweden)

    Alessandro Neri

    2007-01-01

    Full Text Available Standard edge detectors react to all local luminance changes, irrespective of whether they are due to the contours of the objects represented in a scene or due to natural textures like grass, foliage, water, and so forth. Moreover, edges due to texture are often stronger than edges due to object contours. This implies that further processing is needed to discriminate object contours from texture edges. In this paper, we propose a biologically motivated multiresolution contour detection method using Bayesian denoising and a surround inhibition technique. Specifically, the proposed approach deploys computation of the gradient at different resolutions, followed by Bayesian denoising of the edge image. Then, a biologically motivated surround inhibition step is applied in order to suppress edges that are due to texture. We propose an improvement of the surround suppression used in previous works. Finally, a contour-oriented binarization algorithm is used, relying on the observation that object contours lead to long connected components rather than to short rods obtained from textures. Experimental results show that our contour detection method outperforms standard edge detectors as well as other methods that deploy inhibition.

  11. Pulsed laser stereophotography of plasmas and dynamically moving surfaces

    International Nuclear Information System (INIS)

    Paisley, D.L.

    1987-01-01

    A pulsed laser is used as a light source for illuminating the surface of a dynamic event of 3 mm//μs. At a predetermined time during the dynamic action, a stereo camera is used to record a pair of images of the dynamically moving surface. The stereoimage pair can be quantified for surface contour

  12. The equivalent internal orientation and position noise for contour integration.

    Science.gov (United States)

    Baldwin, Alex S; Fu, Minnie; Farivar, Reza; Hess, Robert F

    2017-10-12

    Contour integration is the joining-up of local responses to parts of a contour into a continuous percept. In typical studies observers detect contours formed of discrete wavelets, presented against a background of random wavelets. This measures performance for detecting contours in the limiting external noise that background provides. Our novel task measures contour integration without requiring any background noise. This allowed us to perform noise-masking experiments using orientation and position noise. From these we measure the equivalent internal noise for contour integration. We found an orientation noise of 6° and position noise of 3 arcmin. Orientation noise was 2.6x higher in contour integration compared to an orientation discrimination control task. Comparing against a position discrimination task found position noise in contours to be 2.4x lower. This suggests contour integration involves intermediate processing that enhances the quality of element position representation at the expense of element orientation. Efficiency relative to the ideal observer was lower for the contour tasks (36% in orientation noise, 21% in position noise) compared to the controls (54% and 57%).

  13. Multimodal Registration of gated cardiac PET, CT and MR sequences

    International Nuclear Information System (INIS)

    Baty, X.

    2007-07-01

    The research described in this manuscript deals with the multimodal registration of cardiac images from Magnetic Resonance Imaging (MRI), Position Emission Tomography (PET) and Computerized Tomography (CT). All these modalities are gated to the Electrocardiogram (ECG) and provide information to evaluate cardiac function, and to diagnose and to follow-up cardiovascular pathologies. PET imaging allows the evaluation of ventricular function and MRI is a gold standard for the study of the left ventricular function. The goal of our registration process is to merge functional (from PET) and anatomical images (from CT and MRI). Our process is adapted to the modalities used and is divided in two steps: (i) a global rigid 3-dimensional model-based ICP (Iterative Closest Point) registration between CT and MR data and (ii) an iconic 2-dimensional registration based on Free Form Deformations and Mutual Information. This last step presents an original contribution by using a composite image of CT (which presents epicardic contours) and PET (where endocardic contours are partially visible) data to make mutual information more accurate in representing the similarity with the MR data. To speed up the whole process, we also present a transformation initialization scheme using displacement field obtained form MR data only. The obtained results have been evaluated by experts. (author)

  14. A Combined Random Forests and Active Contour Model Approach for Fully Automatic Segmentation of the Left Atrium in Volumetric MRI

    Directory of Open Access Journals (Sweden)

    Chao Ma

    2017-01-01

    Full Text Available Segmentation of the left atrium (LA from cardiac magnetic resonance imaging (MRI datasets is of great importance for image guided atrial fibrillation ablation, LA fibrosis quantification, and cardiac biophysical modelling. However, automated LA segmentation from cardiac MRI is challenging due to limited image resolution, considerable variability in anatomical structures across subjects, and dynamic motion of the heart. In this work, we propose a combined random forests (RFs and active contour model (ACM approach for fully automatic segmentation of the LA from cardiac volumetric MRI. Specifically, we employ the RFs within an autocontext scheme to effectively integrate contextual and appearance information from multisource images together for LA shape inferring. The inferred shape is then incorporated into a volume-scalable ACM for further improving the segmentation accuracy. We validated the proposed method on the cardiac volumetric MRI datasets from the STACOM 2013 and HVSMR 2016 databases and showed that it outperforms other latest automated LA segmentation methods. Validation metrics, average Dice coefficient (DC and average surface-to-surface distance (S2S, were computed as 0.9227±0.0598 and 1.14±1.205 mm, versus those of 0.6222–0.878 and 1.34–8.72 mm, obtained by other methods, respectively.

  15. A visible light imaging device for cardiac rate detection with reduced effect of body movement

    Science.gov (United States)

    Jiang, Xiaotian; Liu, Ming; Zhao, Yuejin

    2014-09-01

    A visible light imaging system to detect human cardiac rate is proposed in this paper. A color camera and several LEDs, acting as lighting source, were used to avoid the interference of ambient light. From people's forehead, the cardiac rate could be acquired based on photoplethysmography (PPG) theory. The template matching method was used after the capture of video. The video signal was discomposed into three signal channels (RGB) and the region of interest was chosen to take the average gray value. The green channel signal could provide an excellent waveform of pulse wave on the account of green lights' absorptive characteristics of blood. Through the fast Fourier transform, the cardiac rate was exactly achieved. But the research goal was not just to achieve the cardiac rate accurately. With the template matching method, the effects of body movement are reduced to a large extent, therefore the pulse wave can be detected even while people are in the moving state and the waveform is largely optimized. Several experiments are conducted on volunteers, and the results are compared with the ones gained by a finger clamped pulse oximeter. The contrast results between these two ways are exactly agreeable. This method to detect the cardiac rate and the pulse wave largely reduces the effects of body movement and can probably be widely used in the future.

  16. Image Interpolation with Contour Stencils

    OpenAIRE

    Pascal Getreuer

    2011-01-01

    Image interpolation is the problem of increasing the resolution of an image. Linear methods must compromise between artifacts like jagged edges, blurring, and overshoot (halo) artifacts. More recent works consider nonlinear methods to improve interpolation of edges and textures. In this paper we apply contour stencils for estimating the image contours based on total variation along curves and then use this estimation to construct a fast edge-adaptive interpolation.

  17. Interactive 3D segmentation using connected orthogonal contours

    NARCIS (Netherlands)

    de Bruin, P. W.; Dercksen, V. J.; Post, F. H.; Vossepoel, A. M.; Streekstra, G. J.; Vos, F. M.

    2005-01-01

    This paper describes a new method for interactive segmentation that is based on cross-sectional design and 3D modelling. The method represents a 3D model by a set of connected contours that are planar and orthogonal. Planar contours overlayed on image data are easily manipulated and linked contours

  18. Contour plotting programs for printer and Calcomp plotter

    International Nuclear Information System (INIS)

    Moller, P.

    1980-07-01

    Contour plotting programs for plotting contour diagrams on printers or Calcomp plotters are described. The subroutines also exist in versions that are useful for the special application of finding minima and saddlepoints of nuclear potential energy surfaces generated by the subroutine PETR3 of another program package. For the general user, however, the most interesting aspect of the plotting package is probably the possibility of generating printer contour plots. The plotting of printer contour plots is a very fast and convenient way of displaying two-dimensional functions. 3 figures

  19. GPU based contouring method on grid DEM data

    Science.gov (United States)

    Tan, Liheng; Wan, Gang; Li, Feng; Chen, Xiaohui; Du, Wenlong

    2017-08-01

    This paper presents a novel method to generate contour lines from grid DEM data based on the programmable GPU pipeline. The previous contouring approaches often use CPU to construct a finite element mesh from the raw DEM data, and then extract contour segments from the elements. They also need a tracing or sorting strategy to generate the final continuous contours. These approaches can be heavily CPU-costing and time-consuming. Meanwhile the generated contours would be unsmooth if the raw data is sparsely distributed. Unlike the CPU approaches, we employ the GPU's vertex shader to generate a triangular mesh with arbitrary user-defined density, in which the height of each vertex is calculated through a third-order Cardinal spline function. Then in the same frame, segments are extracted from the triangles by the geometry shader, and translated to the CPU-side with an internal order in the GPU's transform feedback stage. Finally we propose a "Grid Sorting" algorithm to achieve the continuous contour lines by travelling the segments only once. Our method makes use of multiple stages of GPU pipeline for computation, which can generate smooth contour lines, and is significantly faster than the previous CPU approaches. The algorithm can be easily implemented with OpenGL 3.3 API or higher on consumer-level PCs.

  20. Active contour-based visual tracking by integrating colors, shapes, and motions.

    Science.gov (United States)

    Hu, Weiming; Zhou, Xue; Li, Wei; Luo, Wenhan; Zhang, Xiaoqin; Maybank, Stephen

    2013-05-01

    In this paper, we present a framework for active contour-based visual tracking using level sets. The main components of our framework include contour-based tracking initialization, color-based contour evolution, adaptive shape-based contour evolution for non-periodic motions, dynamic shape-based contour evolution for periodic motions, and the handling of abrupt motions. For the initialization of contour-based tracking, we develop an optical flow-based algorithm for automatically initializing contours at the first frame. For the color-based contour evolution, Markov random field theory is used to measure correlations between values of neighboring pixels for posterior probability estimation. For adaptive shape-based contour evolution, the global shape information and the local color information are combined to hierarchically evolve the contour, and a flexible shape updating model is constructed. For the dynamic shape-based contour evolution, a shape mode transition matrix is learnt to characterize the temporal correlations of object shapes. For the handling of abrupt motions, particle swarm optimization is adopted to capture the global motion which is applied to the contour in the current frame to produce an initial contour in the next frame.

  1. Noninvasive Body Contouring: A Male Perspective.

    Science.gov (United States)

    Wat, Heidi; Wu, Douglas C; Goldman, Mitchel P

    2018-01-01

    Noninvasive body contouring is an attractive therapeutic modality to enhance the ideal male physique. Men place higher value on enhancing a well-defined, strong, masculine jawline and developing a V-shaped taper through the upper body. An understanding of the body contour men strive for allows the treating physician to focus on areas that are of most concern to men, thus enhancing patient experience and satisfaction. This article discusses noninvasive body contouring techniques, taking into account the unique aesthetic concerns of the male patient by combining an analysis of the existing literature with our own clinical experience. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Summing over Feynman histories by functional contour integration

    International Nuclear Information System (INIS)

    Garrison, J.C.; Wright, E.M.

    1986-01-01

    The authors show how complex paths can be consistently introduced into sums for Feynman histories by using the notion of functional contour integration. For a kappa-dimensional system specified by a potential with suitable analyticity properties, each coordinate axis is replaced by a copy of the complex plane, and at each instant of time a contour is chosen in each plane. This map from the time axis into the set of complex contours defines a functional contour. The family of contours labelled by time generates a (kappa+1)-dimensional submanifold of the (2kappa+1)-dimensional space defined by the cartesian product of the time axis and the coordinate planes. The complex Feynman paths lie on this submanifold. An application of this idea to systems described by absorptive potentials yields a simple derivation of the correct WKB result in terms of a complex path that extremalises the action. The method can also be applied to spherically symmetric potentials by using a partial wave expansion and restricting the contours appropriately. (author)

  3. The HyperV Full-Scale Contoured-Gap Coaxial Plasma Railgun

    Science.gov (United States)

    Brockington, Samuel; Case, Andrew; Messer, Sarah; Bomgardner, Richard; Elton, Raymond; Wu, Linchun; Witherspoon, F. Douglas

    2009-11-01

    HyperV has been developing pulsed plasma injected coaxial railguns with a contoured gap profile designed to mitigate the blowby instability. Previous work using half-scale guns has been successful in launching 150 μg plasmas at 90 km/s [1]. In order to meet the original goal of 200 μg at 200 km/s the full-scale coaxial plasma gun has been constructed, and initial testing is beginning. This new plasma gun consists of two machined aluminum electrodes and a UHMW polyethylene breech insulator. The gun is breech fed by 64 ablative polyethylene capillary discharge units identical to the half-scale gun units. Maximum accelerator energy storage has also been increased 50%. Refractory coatings may be necessary to allow full current (˜800 kA) operation. The outer electrode includes 24 small diagnostic ports for optical and magnetic probe access to the plasma inside the gun to allow direct measurement of the plasma armature dynamics. Initial test data from the full-scale coax gun will be presented along with plans for future testing. Work supported by the U.S. DOE Office of Fusion Energy Sciences.[4pt] [1] F. D. Witherspoon, A. Case, S. Messer, R. Bomgardner, M. Phillips, S. Brockington, R. Elton, ``Contoured Gap Coaxial Plasma Gun with Injected Plasma Armature'' Rev. Sci. Instr. submitted (2009)

  4. Combining prior day contours to improve automated prostate segmentation

    International Nuclear Information System (INIS)

    Godley, Andrew; Sheplan Olsen, Lawrence J.; Stephans, Kevin; Zhao Anzi

    2013-01-01

    Purpose: To improve the accuracy of automatically segmented prostate, rectum, and bladder contours required for online adaptive therapy. The contouring accuracy on the current image guidance [image guided radiation therapy (IGRT)] scan is improved by combining contours from earlier IGRT scans via the simultaneous truth and performance level estimation (STAPLE) algorithm. Methods: Six IGRT prostate patients treated with daily kilo-voltage (kV) cone-beam CT (CBCT) had their original plan CT and nine CBCTs contoured by the same physician. Three types of automated contours were produced for analysis. (1) Plan: By deformably registering the plan CT to each CBCT and then using the resulting deformation field to morph the plan contours to match the CBCT anatomy. (2) Previous: The contour set drawn by the physician on the previous day CBCT is similarly deformed to match the current CBCT anatomy. (3) STAPLE: The contours drawn by the physician, on each prior CBCT and the plan CT, are deformed to match the CBCT anatomy to produce multiple contour sets. These sets are combined using the STAPLE algorithm into one optimal set. Results: Compared to plan and previous, STAPLE improved the average Dice's coefficient (DC) with the original physician drawn CBCT contours to a DC as follows: Bladder: 0.81 ± 0.13, 0.91 ± 0.06, and 0.92 ± 0.06; Prostate: 0.75 ± 0.08, 0.82 ± 0.05, and 0.84 ± 0.05; and Rectum: 0.79 ± 0.06, 0.81 ± 0.06, and 0.85 ± 0.04, respectively. The STAPLE results are within intraobserver consistency, determined by the physician blindly recontouring a subset of CBCTs. Comparing plans recalculated using the physician and STAPLE contours showed an average disagreement less than 1% for prostate D98 and mean dose, and 5% and 3% for bladder and rectum mean dose, respectively. One scan takes an average of 19 s to contour. Using five scans plus STAPLE takes less than 110 s on a 288 core graphics processor unit. Conclusions: Combining the plan and all prior days via

  5. Variation in contour and cancer of stomach

    International Nuclear Information System (INIS)

    Lee, Won Hong; Hwang, Seon Moon; Yoon, Kwon Ha

    1999-01-01

    There were four types of stomach contour included eutonic, hypotonic, steerhorn, and cascade. The aim of this study is to clarify relationship between incidence of stomach cancer and contour variation of the stomach. Double- contrast upper gastrointestinal study was performed in 1,546 patients, who had dyspepsia or other gastrointestinal tract symptoms. The radiographs were classified into the four types including eutonic, hypotonic, steerhorn, and cascade according to stomach contour in relation to body build. We also reviewed pathologic reports on endoscopic biopsy or surgical specimen. We studied the presence of relationship between incidence of stomach cancer and variation of stomach contour. We also examined the incidence of gastritis and gastric ulcer to the stomach contour variation. Of total 1,546 patients, eutonic stomach were 438(28.3%), hypotonic 911(58.9%), steerhorn 102(6.5%) and cascade 95(6.2%). Stomach cancer was found in 139(31.7%) of 438 eutonic stomachs, in 135(14.8%) of 911 hypotonic, in 42(41.2%) of 102 steerhorn, and in 24(36.9%) of 95 cascade (P=0.001). In hypotonic stomach, the incidence of stomach cancer was lower compared to the other three types significantly (p<0.05). Gastritis or gastric ulcer was found in 146(33.3%) of eutonic stomach, in 293(32.1%) of hypotonic, in 36(35.2%) of steerhorn, and in 26(27.3%) of cascade (p=0.640). In conclusion, gastric contour variation seems to be a factor affecting development of stomach cancer. The patients with hypotonic stomach may have lower incidence of stomach cancer than that of the other types. There was no relationship between the contour and gastric ulcer

  6. Variation in contour and cancer of stomach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Hong; Hwang, Seon Moon [Asan Medical Center, Asan (Korea, Republic of); Yoon, Kwon Ha [College of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    1999-04-01

    There were four types of stomach contour included eutonic, hypotonic, steerhorn, and cascade. The aim of this study is to clarify relationship between incidence of stomach cancer and contour variation of the stomach. Double- contrast upper gastrointestinal study was performed in 1,546 patients, who had dyspepsia or other gastrointestinal tract symptoms. The radiographs were classified into the four types including eutonic, hypotonic, steerhorn, and cascade according to stomach contour in relation to body build. We also reviewed pathologic reports on endoscopic biopsy or surgical specimen. We studied the presence of relationship between incidence of stomach cancer and variation of stomach contour. We also examined the incidence of gastritis and gastric ulcer to the stomach contour variation. Of total 1,546 patients, eutonic stomach were 438(28.3%), hypotonic 911(58.9%), steerhorn 102(6.5%) and cascade 95(6.2%). Stomach cancer was found in 139(31.7%) of 438 eutonic stomachs, in 135(14.8%) of 911 hypotonic, in 42(41.2%) of 102 steerhorn, and in 24(36.9%) of 95 cascade (P=0.001). In hypotonic stomach, the incidence of stomach cancer was lower compared to the other three types significantly (p<0.05). Gastritis or gastric ulcer was found in 146(33.3%) of eutonic stomach, in 293(32.1%) of hypotonic, in 36(35.2%) of steerhorn, and in 26(27.3%) of cascade (p=0.640). In conclusion, gastric contour variation seems to be a factor affecting development of stomach cancer. The patients with hypotonic stomach may have lower incidence of stomach cancer than that of the other types. There was no relationship between the contour and gastric ulcer.

  7. An Algorithm for Real-Time Pulse Waveform Segmentation and Artifact Detection in Photoplethysmograms.

    Science.gov (United States)

    Fischer, Christoph; Domer, Benno; Wibmer, Thomas; Penzel, Thomas

    2017-03-01

    Photoplethysmography has been used in a wide range of medical devices for measuring oxygen saturation, cardiac output, assessing autonomic function, and detecting peripheral vascular disease. Artifacts can render the photoplethysmogram (PPG) useless. Thus, algorithms capable of identifying artifacts are critically important. However, the published PPG algorithms are limited in algorithm and study design. Therefore, the authors developed a novel embedded algorithm for real-time pulse waveform (PWF) segmentation and artifact detection based on a contour analysis in the time domain. This paper provides an overview about PWF and artifact classifications, presents the developed PWF analysis, and demonstrates the implementation on a 32-bit ARM core microcontroller. The PWF analysis was validated with data records from 63 subjects acquired in a sleep laboratory, ergometry laboratory, and intensive care unit in equal parts. The output of the algorithm was compared with harmonized experts' annotations of the PPG with a total duration of 31.5 h. The algorithm achieved a beat-to-beat comparison sensitivity of 99.6%, specificity of 90.5%, precision of 98.5%, and accuracy of 98.3%. The interrater agreement expressed as Cohen's kappa coefficient was 0.927 and as F-measure was 0.990. In conclusion, the PWF analysis seems to be a suitable method for PPG signal quality determination, real-time annotation, data compression, and calculation of additional pulse wave metrics such as amplitude, duration, and rise time.

  8. Ingenious Snake: An Adaptive Multi-Class Contours Extraction

    Science.gov (United States)

    Li, Baolin; Zhou, Shoujun

    2018-04-01

    Active contour model (ACM) plays an important role in computer vision and medical image application. The traditional ACMs were used to extract single-class of object contours. While, simultaneous extraction of multi-class of interesting contours (i.e., various contours with closed- or open-ended) have not been solved so far. Therefore, a novel ACM model named “Ingenious Snake” is proposed to adaptively extract these interesting contours. In the first place, the ridge-points are extracted based on the local phase measurement of gradient vector flow field; the consequential ridgelines initialization are automated with high speed. Secondly, the contours’ deformation and evolvement are implemented with the ingenious snake. In the experiments, the result from initialization, deformation and evolvement are compared with the existing methods. The quantitative evaluation of the structure extraction is satisfying with respect of effectiveness and accuracy.

  9. Gated magnetic resonance imaging of congenital cardiac malformations

    International Nuclear Information System (INIS)

    Fletcher, B.D.; Jocobstein, M.D.; Nelson, A.D.; Riemenschneider, T.A.; Alfidi, R.J.

    1984-01-01

    Magnetic resonance (MR) images of a variety of cardiac malformations in 19 patients aged 1 week to 33 years were obtained using pulse plethysmographic- or ECG-gated spin echo pulse sequences. Coronal, axial, and sagittal images displaying intracardiac structures with excellent spatial and contrast resolution were acquired during systole or diastole. It is concluded that MR will be a valuable noninvasive method of diagnosing congenital heart disease

  10. Low level constraints on dynamic contour path integration.

    Directory of Open Access Journals (Sweden)

    Sophie Hall

    Full Text Available Contour integration is a fundamental visual process. The constraints on integrating discrete contour elements and the associated neural mechanisms have typically been investigated using static contour paths. However, in our dynamic natural environment objects and scenes vary over space and time. With the aim of investigating the parameters affecting spatiotemporal contour path integration, we measured human contrast detection performance of a briefly presented foveal target embedded in dynamic collinear stimulus sequences (comprising five short 'predictor' bars appearing consecutively towards the fovea, followed by the 'target' bar in four experiments. The data showed that participants' target detection performance was relatively unchanged when individual contour elements were separated by up to 2° spatial gap or 200 ms temporal gap. Randomising the luminance contrast or colour of the predictors, on the other hand, had similar detrimental effect on grouping dynamic contour path and subsequent target detection performance. Randomising the orientation of the predictors reduced target detection performance greater than introducing misalignment relative to the contour path. The results suggest that the visual system integrates dynamic path elements to bias target detection even when the continuity of path is disrupted in terms of spatial (2°, temporal (200 ms, colour (over 10 colours and luminance (-25% to 25% information. We discuss how the findings can be largely reconciled within the functioning of V1 horizontal connections.

  11. Evaluating the cardiac function of duchenne muscular dystrophy with Doppler Tei index

    International Nuclear Information System (INIS)

    Yao Fengjuan; Zheng Ju; Lu Kun; Liu Donghong; Wu Miaoling; Lin Hong; Zhang Cheng; Yu Hongkui

    2007-01-01

    Objective: To evaluate the cardiac function of early Duchenne muscular dystrophy (DMD) by left ventricular ejection fraction (LVEF) and pulse Doppler Tei index. Methods: Twenty-eight DMD patients and fifteen normal people were studied. LVEF, E/A and Tei index were measured and calculated by M-mode and Pulse wave Doppler respectively. Results: Compared with control group, Tei index and IRT were significantly high, and there were not significant difference in LVEF(%) and E/A. Conclusion: Tei index was valuable in assessing cardiac function of early DMD. (authors)

  12. Spatial profile of contours inducing long-range color assimilation.

    Science.gov (United States)

    Devinck, Frédéric; Spillmann, Lothar; Werner, John S

    2006-01-01

    Color induction was measured using a matching method for two spatial patterns, each composed of double contours. In one pattern (the standard), the contours had sharp edges to induce the Watercolor Effect (WCE); in the other, the two contours had a spatial taper so that the overall profile produced a sawtooth edge, or ramped stimulus. These patterns were chosen based on our previous study demonstrating that the strength of the chromatic WCE depends on a luminance difference between the two contours. Low-pass chromatic mechanisms, unlike bandpass luminance mechanisms, may be expected to be insensitive to the difference between the two spatial profiles. The strength of the watercolor spreading was similar for the two patterns at narrow widths of the contour possibly because of chromatic aberration, but with wider contours, the standard stimulus produced stronger assimilation than the ramped stimulus. This research suggests that luminance-dependent chromatic mechanisms mediate the WCE and that these mechanisms are sensitive to differences in the two spatial profiles of the pattern contours only when they are wide.

  13. Effect of Twisted Fiber Anisotropy in Cardiac Tissue on Ablation with Pulsed Electric Fields.

    Directory of Open Access Journals (Sweden)

    Fei Xie

    Full Text Available Ablation of cardiac tissue with pulsed electric fields is a promising alternative to current thermal ablation methods, and it critically depends on the electric field distribution in the heart.We developed a model that incorporates the twisted anisotropy of cardiac tissue and computed the electric field distribution in the tissue. We also performed experiments in rabbit ventricles to validate our model. We find that the model agrees well with the experimentally determined ablation volume if we assume that all tissue that is exposed to a field greater than 3 kV/cm is ablated. In our numerical analysis, we considered how tissue thickness, degree of anisotropy, and electrode configuration affect the geometry of the ablated volume. We considered two electrode configurations: two parallel needles inserted into the myocardium ("penetrating needles" configuration and one circular electrode each on epi- and endocardium, opposing each other ("epi-endo" configuration.For thick tissues (10 mm and moderate anisotropy ratio (a = 2, we find that the geometry of the ablated volume is almost unaffected by twisted anisotropy, i.e. it is approximately translationally symmetric from epi- to endocardium, for both electrode configurations. Higher anisotropy ratio (a = 10 leads to substantial variation in ablation width across the wall; these variations were more pronounced for the penetrating needle configuration than for the epi-endo configuration. For thinner tissues (4 mm, typical for human atria and higher anisotropy ratio (a = 10, the epi-endo configuration yielded approximately translationally symmetric ablation volumes, while the penetrating electrodes configuration was much more sensitive to fiber twist.These results suggest that the epi-endo configuration will be reliable for ablation of atrial fibrillation, independently of fiber orientation, while the penetrating electrode configuration may experience problems when the fiber orientation is not consistent

  14. Effect of Twisted Fiber Anisotropy in Cardiac Tissue on Ablation with Pulsed Electric Fields.

    Science.gov (United States)

    Xie, Fei; Zemlin, Christian W

    2016-01-01

    Ablation of cardiac tissue with pulsed electric fields is a promising alternative to current thermal ablation methods, and it critically depends on the electric field distribution in the heart. We developed a model that incorporates the twisted anisotropy of cardiac tissue and computed the electric field distribution in the tissue. We also performed experiments in rabbit ventricles to validate our model. We find that the model agrees well with the experimentally determined ablation volume if we assume that all tissue that is exposed to a field greater than 3 kV/cm is ablated. In our numerical analysis, we considered how tissue thickness, degree of anisotropy, and electrode configuration affect the geometry of the ablated volume. We considered two electrode configurations: two parallel needles inserted into the myocardium ("penetrating needles" configuration) and one circular electrode each on epi- and endocardium, opposing each other ("epi-endo" configuration). For thick tissues (10 mm) and moderate anisotropy ratio (a = 2), we find that the geometry of the ablated volume is almost unaffected by twisted anisotropy, i.e. it is approximately translationally symmetric from epi- to endocardium, for both electrode configurations. Higher anisotropy ratio (a = 10) leads to substantial variation in ablation width across the wall; these variations were more pronounced for the penetrating needle configuration than for the epi-endo configuration. For thinner tissues (4 mm, typical for human atria) and higher anisotropy ratio (a = 10), the epi-endo configuration yielded approximately translationally symmetric ablation volumes, while the penetrating electrodes configuration was much more sensitive to fiber twist. These results suggest that the epi-endo configuration will be reliable for ablation of atrial fibrillation, independently of fiber orientation, while the penetrating electrode configuration may experience problems when the fiber orientation is not consistent across the

  15. Roentgenological differential diagnosis of the psoas contour

    International Nuclear Information System (INIS)

    Voran, G.; Pfab, R.; Hess, F.

    1984-01-01

    The assessment of the psoas border contour in the X-ray photo of the abdomen is important for differential diagnostic considerations. For the separation of fallacious psoas configurations which are similar to the well defined pathological form changes, a regular supine position of the patient was chosen, and the psoas examined without and with muscle tension. The whole visible psoas muscle system did not show any unilateral bulging of the border silhouette during muscle action. Isolated tension of the left psoas muscle induced a distinct deviation of both border contours to the left side, too. There was a clear tendency of a more distinct psoas border contour and of augmented opacity of the muscle over its whole length under muscle tension. Changes similar to the bulging border contour of a psoas abscess were not produced by muscular action. (orig.) [de

  16. [Development of a Software for Automatically Generated Contours in Eclipse TPS].

    Science.gov (United States)

    Xie, Zhao; Hu, Jinyou; Zou, Lian; Zhang, Weisha; Zou, Yuxin; Luo, Kelin; Liu, Xiangxiang; Yu, Luxin

    2015-03-01

    The automatic generation of planning targets and auxiliary contours have achieved in Eclipse TPS 11.0. The scripting language autohotkey was used to develop a software for automatically generated contours in Eclipse TPS. This software is named Contour Auto Margin (CAM), which is composed of operational functions of contours, script generated visualization and script file operations. RESULTS Ten cases in different cancers have separately selected, in Eclipse TPS 11.0 scripts generated by the software could not only automatically generate contours but also do contour post-processing. For different cancers, there was no difference between automatically generated contours and manually created contours. The CAM is a user-friendly and powerful software, and can automatically generated contours fast in Eclipse TPS 11.0. With the help of CAM, it greatly save plan preparation time and improve working efficiency of radiation therapy physicists.

  17. Incomplete contour representations and shape descriptors : ICR test studies

    NARCIS (Netherlands)

    Ghosh, Anarta; Petkov, Nicolai; Gregorio, MD; DiMaio,; Frucci, M; Musio, C

    2005-01-01

    Inspired by psychophysical studies of the human cognitive abilities we propose a novel aspect and a method for performance evaluation of contour based shape recognition algorithms regarding their robustness to incompleteness of contours. We use complete contour representations of objects as a

  18. The self-assembly, elasticity, and dynamics of cardiac thin filaments.

    Science.gov (United States)

    Tassieri, M; Evans, R M L; Barbu-Tudoran, L; Trinick, J; Waigh, T A

    2008-03-15

    Solutions of intact cardiac thin filaments were examined with transmission electron microscopy, dynamic light scattering (DLS), and particle-tracking microrheology. The filaments self-assembled in solution with a bell-shaped distribution of contour lengths that contained a population of filaments of much greater length than the in vivo sarcomere size ( approximately 1 mum) due to a one-dimensional annealing process. Dynamic semiflexible modes were found in DLS measurements at fast timescales (12.5 ns-0.0001 s). The bending modulus of the fibers is found to be in the range 4.5-16 x 10(-27) Jm and is weakly dependent on calcium concentration (with Ca2+ > or = without Ca2+). Good quantitative agreement was found for the values of the fiber diameter calculated from transmission electron microscopy and from the initial decay of DLS correlation functions: 9.9 nm and 9.7 nm with and without Ca2+, respectively. In contrast, at slower timescales and high polymer concentrations, microrheology indicates that the cardiac filaments act as short rods in solution according to the predictions of the Doi-Edwards chopsticks model (viscosity, eta approximately c(3), where c is the polymer concentration). This differs from the semiflexible behavior of long synthetic actin filaments at comparable polymer concentrations and timescales (elastic shear modulus, G' approximately c(1.4), tightly entangled) and is due to the relative ratio of the contour lengths ( approximately 30). The scaling dependence of the elastic shear modulus on the frequency (omega) for cardiac thin filaments is G' approximately omega(3/4 +/- 0.03), which is thought to arise from flexural modes of the filaments.

  19. SU-C-BRB-05: Determining the Adequacy of Auto-Contouring Via Probabilistic Assessment of Ensuing Treatment Plan Metrics in Comparison with Manual Contours

    International Nuclear Information System (INIS)

    Nourzadeh, H; Watkins, W; Siebers, J; Ahmad, M

    2016-01-01

    Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampled systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto-contour needs

  20. SU-C-BRB-05: Determining the Adequacy of Auto-Contouring Via Probabilistic Assessment of Ensuing Treatment Plan Metrics in Comparison with Manual Contours

    Energy Technology Data Exchange (ETDEWEB)

    Nourzadeh, H; Watkins, W; Siebers, J; Ahmad, M [University of Virginia Health Systems, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampled systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto-contour needs

  1. Invariance Signatures: Characterizing contours by their departures from invariance

    OpenAIRE

    Squire, David; Caelli, Terry M.

    1997-01-01

    In this paper, a new invariant feature of two-dimensional contours is reported: the Invariance Signature. The Invariance Signature is a measure of the degree to which a contour is invariant under a variety of transformations, derived from the theory of Lie transformation groups. It is shown that the Invariance Signature is itself invariant under shift, rotation and scaling of the contour. Since it is derived from local properties of the contour, it is well-suited to a neural network implement...

  2. A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

    Science.gov (United States)

    Schmitt, Melanie; Potthast, Andreas; Sosnovik, David E; Polimeni, Jonathan R; Wiggins, Graham C; Triantafyllou, Christina; Wald, Lawrence L

    2008-06-01

    A 128-channel receive-only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a "clam-shell" geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging (G-factor) were evaluated in phantom and volunteer experiments. These results were compared to those of commercially available 24-channel and 32-channel coils in routine use for cardiac imaging. The in vivo measurements with the 128-channel coil resulted in SNR gains compared to the 24-channel coil (up to 2.2-fold in the apex). The 128- and 32-channel coils showed similar SNR in the heart, likely dominated by the similar element diameters of these coils. The maximum G-factor values were up to seven times better for a seven-fold acceleration factor (R=7) compared to the 24-channel coil and up to two-fold improved compared to the 32-channel coil. The ability of the 128-channel coil to facilitate highly accelerated cardiac imaging was demonstrated in four volunteers using acceleration factors up to seven-fold (R=7) in a single spatial dimension. Copyright (c) 2008 Wiley-Liss, Inc.

  3. Cheap contouring of costly functions: the Pilot Approximation Trajectory algorithm

    International Nuclear Information System (INIS)

    Huttunen, Janne M J; Stark, Philip B

    2012-01-01

    The Pilot Approximation Trajectory (PAT) contour algorithm can find the contour of a function accurately when it is not practical to evaluate the function on a grid dense enough to use a standard contour algorithm, for instance, when evaluating the function involves conducting a physical experiment or a computationally intensive simulation. PAT relies on an inexpensive pilot approximation to the function, such as interpolating from a sparse grid of inexact values, or solving a partial differential equation (PDE) numerically using a coarse discretization. For each level of interest, the location and ‘trajectory’ of an approximate contour of this pilot function are used to decide where to evaluate the original function to find points on its contour. Those points are joined by line segments to form the PAT approximation of the contour of the original function. Approximating a contour numerically amounts to estimating a lower level set of the function, the set of points on which the function does not exceed the contour level. The area of the symmetric difference between the true lower level set and the estimated lower level set measures the accuracy of the contour. PAT measures its own accuracy by finding an upper confidence bound for this area. In examples, PAT can estimate a contour more accurately than standard algorithms, using far fewer function evaluations than standard algorithms require. We illustrate PAT by constructing a confidence set for viscosity and thermal conductivity of a flowing gas from simulated noisy temperature measurements, a problem in which each evaluation of the function to be contoured requires solving a different set of coupled nonlinear PDEs. (paper)

  4. VT 10 ft Contour Lines generated from bare earth lidar - Chittenden

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) ElevationContours_CN10T (10ft contours) was extracted from ElevationContours_CN2T (2ft contours), which was generated by USGS from the 2004...

  5. Spiral Light Beams and Contour Image Processing

    Science.gov (United States)

    Kishkin, Sergey A.; Kotova, Svetlana P.; Volostnikov, Vladimir G.

    Spiral beams of light are characterized by their ability to remain structurally unchanged at propagation. They may have the shape of any closed curve. In the present paper a new approach is proposed within the framework of the contour analysis based on a close cooperation of modern coherent optics, theory of functions and numerical methods. An algorithm for comparing contours is presented and theoretically justified, which allows convincing of whether two contours are similar or not to within the scale factor and/or rotation. The advantages and disadvantages of the proposed approach are considered; the results of numerical modeling are presented.

  6. Contour adaptation reduces the spreading of edge induced colors.

    Science.gov (United States)

    Coia, Andrew J; Crognale, Michael A

    2017-04-25

    Brief exposure to flickering achromatic outlines of an area causes a reduction in the brightness contrast of the surface inside the area. This contour adaptation to achromatic contours does not reduce surface contrast when the surface is chromatic (the saturation or colorimetric purity of the surface is maintained). In addition to reducing the brightness of physical luminance contrast, contour adaptation also reduces (or even reverses) the illusory brightness contrast seen in the Craik-O'Brien-Cornsweet illusion, in which two physically identical grey areas appear different brightness because of a sharp luminance edge separating them. Chromatic color spreading illusions also occur with chromatic inducing edges, and an unanswered question is whether contour adaptation can reduce the perceived contrast of illusory color spreading from edges, even though it cannot reduce the perceived contrast of physical surface color. The current studies use a color spreading illusion known as the watercolor effect in order to test whether illusory color spreading is affected by contour adaptation. The general findings of physical achromatic contrast being reduced and chromatic contrast being robust to contour adaptation were replicated. However, both illusory brightness and color were reduced by contour adaptation, even when the illusion edges only differed in chromatic contrast with each other and the background. Additional studies adapting to chromatic contours showed opposite effects on illusory color contrast than achromatic adaptation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. The role of shape complexity in the detection of closed contours.

    Science.gov (United States)

    Wilder, John; Feldman, Jacob; Singh, Manish

    2016-09-01

    The detection of contours in noise has been extensively studied, but the detection of closed contours, such as the boundaries of whole objects, has received relatively little attention. Closed contours pose substantial challenges not present in the simple (open) case, because they form the outlines of whole shapes and thus take on a range of potentially important configural properties. In this paper we consider the detection of closed contours in noise as a probabilistic decision problem. Previous work on open contours suggests that contour complexity, quantified as the negative log probability (Description Length, DL) of the contour under a suitably chosen statistical model, impairs contour detectability; more complex (statistically surprising) contours are harder to detect. In this study we extended this result to closed contours, developing a suitable probabilistic model of whole shapes that gives rise to several distinct though interrelated measures of shape complexity. We asked subjects to detect either natural shapes (Exp. 1) or experimentally manipulated shapes (Exp. 2) embedded in noise fields. We found systematic effects of global shape complexity on detection performance, demonstrating how aspects of global shape and form influence the basic process of object detection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Contour Propagation Using Feature-Based Deformable Registration for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yuhan Yang

    2013-01-01

    Full Text Available Accurate target delineation of CT image is a critical step in radiotherapy treatment planning. This paper describes a novel strategy for automatic contour propagation, based on deformable registration, for CT images of lung cancer. The proposed strategy starts with a manual-delineated contour in one slice of a 3D CT image. By means of feature-based deformable registration, the initial contour in other slices of the image can be propagated automatically, and then refined by active contour approach. Three algorithms are employed in the strategy: the Speeded-Up Robust Features (SURF, Thin-Plate Spline (TPS, and an adapted active contour (Snake, used to refine and modify the initial contours. Five pulmonary cancer cases with about 400 slices and 1000 contours have been used to verify the proposed strategy. Experiments demonstrate that the proposed strategy can improve the segmentation performance in the pulmonary CT images. Jaccard similarity (JS mean is about 0.88 and the maximum of Hausdorff distance (HD is about 90%. In addition, delineation time has been considerably reduced. The proposed feature-based deformable registration method in the automatic contour propagation improves the delineation efficiency significantly.

  9. Rapid detection of cardiac troponin I using antibody-immobilized gate-pulsed AlGaN/GaN high electron mobility transistor structures

    Science.gov (United States)

    Yang, Jiancheng; Carey, Patrick; Ren, Fan; Wang, Yu-Lin; Good, Michael L.; Jang, Soohwan; Mastro, Michael A.; Pearton, S. J.

    2017-11-01

    We report a comparison of two different approaches to detecting cardiac troponin I (cTnI) using antibody-functionalized AlGaN/GaN High Electron Mobility Transistors (HEMTs). If the solution containing the biomarker has high ionic strength, there can be difficulty in detection due to charge-screening effects. To overcome this, in the first approach, we used a recently developed method involving pulsed biases applied between a separate functionalized electrode and the gate of the HEMT. The resulting electrical double layer produces charge changes which are correlated with the concentration of the cTnI biomarker. The second approach fabricates the sensing area on a glass slide, and the pulsed gate signal is externally connected to the nitride HEMT. This produces a larger integrated change in charge and can be used over a broader range of concentrations without suffering from charge-screening effects. Both approaches can detect cTnI at levels down to 0.01 ng/ml. The glass slide approach is attractive for inexpensive cartridge-type sensors.

  10. Data integrity systems for organ contours in radiation therapy planning.

    Science.gov (United States)

    Shah, Veeraj P; Lakshminarayanan, Pranav; Moore, Joseph; Tran, Phuoc T; Quon, Harry; Deville, Curtiland; McNutt, Todd R

    2018-06-12

    The purpose of this research is to develop effective data integrity models for contoured anatomy in a radiotherapy workflow for both real-time and retrospective analysis. Within this study, two classes of contour integrity models were developed: data driven models and contiguousness models. The data driven models aim to highlight contours which deviate from a gross set of contours from similar disease sites and encompass the following regions of interest (ROI): bladder, femoral heads, spinal cord, and rectum. The contiguousness models, which individually analyze the geometry of contours to detect possible errors, are applied across many different ROI's and are divided into two metrics: Extent and Region Growing over volume. After analysis, we found that 70% of detected bladder contours were verified as suspicious. The spinal cord and rectum models verified that 73% and 80% of contours were suspicious respectively. The contiguousness models were the most accurate models and the Region Growing model was the most accurate submodel. 100% of the detected noncontiguous contours were verified as suspicious, but in the cases of spinal cord, femoral heads, bladder, and rectum, the Region Growing model detected additional two to five suspicious contours that the Extent model failed to detect. When conducting a blind review to detect false negatives, it was found that all the data driven models failed to detect all suspicious contours. The Region Growing contiguousness model produced zero false negatives in all regions of interest other than prostate. With regards to runtime, the contiguousness via extent model took an average of 0.2 s per contour. On the other hand, the region growing method had a longer runtime which was dependent on the number of voxels in the contour. Both contiguousness models have potential for real-time use in clinical radiotherapy while the data driven models are better suited for retrospective use. © 2018 The Authors. Journal of Applied Clinical

  11. Perceptual representation and effectiveness of local figure-ground cues in natural contours.

    Science.gov (United States)

    Sakai, Ko; Matsuoka, Shouhei; Kurematsu, Ken; Hatori, Yasuhiro

    2015-01-01

    A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure-ground segregation. Although previous studies have reported local contour features that evoke figure-ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural contour shapes. We performed similarity tests between local contours, and examined the contribution of the contour features to the perceptual similarities between the contours. The local contours were sampled from natural contours so that their distribution was uniform in the space composed of the three contour features. This sampling ensured the equal appearance frequency of the factors and a wide variety of contour shapes including those comprised of contradictory factors that induce figure in the opposite directions. This sampling from natural contours is advantageous in order to randomly pickup a variety of contours that satisfy a wide range of cue combinations. Multidimensional scaling analyses showed that the combinations of convexity, closure, and symmetry contribute to perceptual similarity, thus they are perceptual quantities. Second, we examined whether the three features contribute to local figure-ground perception. We performed psychophysical experiments to judge the direction of the figure along the local contours, and examined the contribution of the features to the figure-ground judgment. Multiple linear regression analyses showed that closure was a significant factor, but that convexity and symmetry were not. These results indicate that closure is dominant in the local figure-ground perception with natural contours when the other cues coexist with equal probability including contradictory cases.

  12. Perceptual representation and effectiveness of local figure–ground cues in natural contours

    Science.gov (United States)

    Sakai, Ko; Matsuoka, Shouhei; Kurematsu, Ken; Hatori, Yasuhiro

    2015-01-01

    A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure–ground segregation. Although previous studies have reported local contour features that evoke figure–ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural contour shapes. We performed similarity tests between local contours, and examined the contribution of the contour features to the perceptual similarities between the contours. The local contours were sampled from natural contours so that their distribution was uniform in the space composed of the three contour features. This sampling ensured the equal appearance frequency of the factors and a wide variety of contour shapes including those comprised of contradictory factors that induce figure in the opposite directions. This sampling from natural contours is advantageous in order to randomly pickup a variety of contours that satisfy a wide range of cue combinations. Multidimensional scaling analyses showed that the combinations of convexity, closure, and symmetry contribute to perceptual similarity, thus they are perceptual quantities. Second, we examined whether the three features contribute to local figure–ground perception. We performed psychophysical experiments to judge the direction of the figure along the local contours, and examined the contribution of the features to the figure–ground judgment. Multiple linear regression analyses showed that closure was a significant factor, but that convexity and symmetry were not. These results indicate that closure is dominant in the local figure–ground perception with natural contours when the other cues coexist with equal probability including contradictory cases. PMID:26579057

  13. Perceptual Representation and Effectiveness of Local Figure-Ground Cues in Natural Contours

    Directory of Open Access Journals (Sweden)

    Ko eSakai

    2015-11-01

    Full Text Available A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure-ground segregation. Although previous studies have reported local contour features that evoke figure-ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural contour shapes. We performed similarity tests between local contours, and examined the contribution of the contour features to the perceptual similarities between the contours. The local contours were sampled from natural contours so that their distribution was uniform in the space composed of the three contour features. This sampling ensured the equal appearance frequency of the factors and a wide variety of contour shapes including those comprised of contradictory factors that induce figure in the opposite directions. This sampling from natural contours is advantageous in order to randomly pickup a variety of contours that satisfy a wide range of cue combinations. Multidimensional scaling analyses showed that the combinations of convexity, closure, and symmetry contribute to perceptual similarity, thus they are perceptual quantities. Second, we examined whether the three features contribute to local figure-ground perception. We performed psychophysical experiments to judge the direction of the figure along the local contours, and examined the contribution of the features to the figure-ground judgment. Multiple linear regression analyses showed that closure was a significant factor, but that convexity and symmetry were not. These results indicate that closure is dominant in the local figure-ground perception with natural contours when the other cues coexist with equal probability including contradictory cases.

  14. Hand-Geometry Recognition Based on Contour Parameters

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Booij, W.D.T.; Hendrikse, A.J.; Jain, A.K.; Ratha, N.K.

    This paper demonstrates the feasibility of a new method of hand-geometry recognition based on parameters derived from the contour of the hand. The contour is completely determined by the black-and-white image of the hand and can be derived from it by means of simple image-processing techniques. It

  15. Prostate Contouring Variation: Can It Be Fixed?

    International Nuclear Information System (INIS)

    Khoo, Eric L.H.; Schick, Karlissa; Plank, Ashley W.; Poulsen, Michael; Wong, Winnie W.G.; Middleton, Mark; Martin, Jarad M.

    2012-01-01

    Purpose: To assess whether an education program on CT and MRI prostate anatomy would reduce inter- and intraobserver prostate contouring variation among experienced radiation oncologists. Methods and Materials: Three patient CT and MRI datasets were selected. Five radiation oncologists contoured the prostate for each patient on CT first, then MRI, and again between 2 and 4 weeks later. Three education sessions were then conducted. The same contouring process was then repeated with the same datasets and oncologists. The observer variation was assessed according to changes in the ratio of the encompassing volume to intersecting volume (volume ratio [VR]), across sets of target volumes. Results: For interobserver variation, there was a 15% reduction in mean VR with CT, from 2.74 to 2.33, and a 40% reduction in mean VR with MRI, from 2.38 to 1.41 after education. A similar trend was found for intraobserver variation, with a mean VR reduction for CT and MRI of 9% (from 1.51 to 1.38) and 16% (from 1.37 to 1.15), respectively. Conclusion: A well-structured education program has reduced both inter- and intraobserver prostate contouring variations. The impact was greater on MRI than on CT. With the ongoing incorporation of new technologies into routine practice, education programs for target contouring should be incorporated as part of the continuing medical education of radiation oncologists.

  16. A Voronoi interior adjacency-based approach for generating a contour tree

    Science.gov (United States)

    Chen, Jun; Qiao, Chaofei; Zhao, Renliang

    2004-05-01

    A contour tree is a good graphical tool for representing the spatial relations of contour lines and has found many applications in map generalization, map annotation, terrain analysis, etc. A new approach for generating contour trees by introducing a Voronoi-based interior adjacency set concept is proposed in this paper. The immediate interior adjacency set is employed to identify all of the children contours of each contour without contour elevations. It has advantages over existing methods such as the point-in-polygon method and the region growing-based method. This new approach can be used for spatial data mining and knowledge discovering, such as the automatic extraction of terrain features and construction of multi-resolution digital elevation model.

  17. Shape reconstruction from apparent contours theory and algorithms

    CERN Document Server

    Bellettini, Giovanni; Paolini, Maurizio

    2015-01-01

    Motivated by a variational model concerning the depth of the objects in a picture and the problem of hidden and illusory contours, this book investigates one of the central problems of computer vision: the topological and algorithmic reconstruction of a smooth three dimensional scene starting from the visible part of an apparent contour. The authors focus their attention on the manipulation of apparent contours using a finite set of elementary moves, which correspond to diffeomorphic deformations of three dimensional scenes. A large part of the book is devoted to the algorithmic part, with implementations, experiments, and computed examples. The book is intended also as a user's guide to the software code appcontour, written for the manipulation of apparent contours and their invariants. This book is addressed to theoretical and applied scientists working in the field of mathematical models of image segmentation.

  18. Automated segmentation and reconstruction of patient-specific cardiac anatomy and pathology from in vivo MRI

    International Nuclear Information System (INIS)

    Ringenberg, Jordan; Deo, Makarand; Devabhaktuni, Vijay; Filgueiras-Rama, David; Pizarro, Gonzalo; Ibañez, Borja; Berenfeld, Omer; Boyers, Pamela; Gold, Jeffrey

    2012-01-01

    This paper presents an automated method to segment left ventricle (LV) tissues from functional and delayed-enhancement (DE) cardiac magnetic resonance imaging (MRI) scans using a sequential multi-step approach. First, a region of interest (ROI) is computed to create a subvolume around the LV using morphological operations and image arithmetic. From the subvolume, the myocardial contours are automatically delineated using difference of Gaussians (DoG) filters and GSV snakes. These contours are used as a mask to identify pathological tissues, such as fibrosis or scar, within the DE-MRI. The presented automated technique is able to accurately delineate the myocardium and identify the pathological tissue in patient sets. The results were validated by two expert cardiologists, and in one set the automated results are quantitatively and qualitatively compared with expert manual delineation. Furthermore, the method is patient-specific, performed on an entire patient MRI series. Thus, in addition to providing a quick analysis of individual MRI scans, the fully automated segmentation method is used for effectively tagging regions in order to reconstruct computerized patient-specific 3D cardiac models. These models can then be used in electrophysiological studies and surgical strategy planning. (paper)

  19. Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer.

    Science.gov (United States)

    Lustberg, Tim; van Soest, Johan; Gooding, Mark; Peressutti, Devis; Aljabar, Paul; van der Stoep, Judith; van Elmpt, Wouter; Dekker, Andre

    2018-02-01

    Contouring of organs at risk (OARs) is an important but time consuming part of radiotherapy treatment planning. The aim of this study was to investigate whether using institutional created software-generated contouring will save time if used as a starting point for manual OAR contouring for lung cancer patients. Twenty CT scans of stage I-III NSCLC patients were used to compare user adjusted contours after an atlas-based and deep learning contour, against manual delineation. The lungs, esophagus, spinal cord, heart and mediastinum were contoured for this study. The time to perform the manual tasks was recorded. With a median time of 20 min for manual contouring, the total median time saved was 7.8 min when using atlas-based contouring and 10 min for deep learning contouring. Both atlas based and deep learning adjustment times were significantly lower than manual contouring time for all OARs except for the left lung and esophagus of the atlas based contouring. User adjustment of software generated contours is a viable strategy to reduce contouring time of OARs for lung radiotherapy while conforming to local clinical standards. In addition, deep learning contouring shows promising results compared to existing solutions. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Late Ratchet syndrome involving isolated left ventricular lead dislodgement post-cardiac resynchronization therapy defibrillator generator change.

    Science.gov (United States)

    Tan, Vern Hsen; Wong, Kelvin

    2018-04-01

    Lead dislodgement following cardiac implantable electronic device (CIED) generator change is rare. We report a case including the postulate mechanism of an isolated left ventricular lead dislodgement 3 months after cardiac resynchronization therapy defibrillator pulse generator change.

  1. Auto-propagation of contours for adaptive prostate radiation therapy

    International Nuclear Information System (INIS)

    Chao Ming; Xie Yaoqin; Xing Lei

    2008-01-01

    The purpose of this work is to develop an effective technique to automatically propagate contours from planning CT to cone beam CT (CBCT) to facilitate CBCT-guided prostate adaptive radiation therapy. Different from other disease sites, such as the lungs, the contour mapping here is complicated by two factors: (i) the physical one-to-one correspondence may not exist due to the insertion or removal of some image contents within the region of interest (ROI); and (ii) reduced contrast to noise ratio of the CBCT images due to increased scatter. To overcome these issues, we investigate a strategy of excluding the regions with variable contents by a careful design of a narrow shell signifying the contour of an ROI. For rectum, for example, a narrow shell with the delineated contours as its interior surface was constructed to avoid the adverse influence of the day-to-day content change inside the rectum on the contour mapping. The corresponding contours in the CBCT were found by warping the narrow shell through the use of BSpline deformable model. Both digital phantom experiments and clinical case testing were carried out to validate the proposed ROI mapping method. It was found that the approach was able to reliably warp the constructed narrow band with an accuracy better than 1.3 mm. For all five clinical cases enrolled in this study, the method yielded satisfactory results even when there were significant rectal content changes between the planning CT and CBCT scans. The overlapped area of the auto-mapped contours over 90% to the manually drawn contours is readily achievable. The proposed approach permits us to take advantage of the regional calculation algorithm yet avoiding the nuisance of rectum/bladder filling and provide a useful tool for adaptive radiotherapy of prostate in the future

  2. Auto-propagation of contours for adaptive prostate radiation therapy

    Science.gov (United States)

    Chao, Ming; Xie, Yaoqin; Xing, Lei

    2008-09-01

    The purpose of this work is to develop an effective technique to automatically propagate contours from planning CT to cone beam CT (CBCT) to facilitate CBCT-guided prostate adaptive radiation therapy. Different from other disease sites, such as the lungs, the contour mapping here is complicated by two factors: (i) the physical one-to-one correspondence may not exist due to the insertion or removal of some image contents within the region of interest (ROI); and (ii) reduced contrast to noise ratio of the CBCT images due to increased scatter. To overcome these issues, we investigate a strategy of excluding the regions with variable contents by a careful design of a narrow shell signifying the contour of an ROI. For rectum, for example, a narrow shell with the delineated contours as its interior surface was constructed to avoid the adverse influence of the day-to-day content change inside the rectum on the contour mapping. The corresponding contours in the CBCT were found by warping the narrow shell through the use of BSpline deformable model. Both digital phantom experiments and clinical case testing were carried out to validate the proposed ROI mapping method. It was found that the approach was able to reliably warp the constructed narrow band with an accuracy better than 1.3 mm. For all five clinical cases enrolled in this study, the method yielded satisfactory results even when there were significant rectal content changes between the planning CT and CBCT scans. The overlapped area of the auto-mapped contours over 90% to the manually drawn contours is readily achievable. The proposed approach permits us to take advantage of the regional calculation algorithm yet avoiding the nuisance of rectum/bladder filling and provide a useful tool for adaptive radiotherapy of prostate in the future.

  3. Auto-propagation of contours for adaptive prostate radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chao Ming; Xie Yaoqin; Xing Lei [Department of Radiation Oncology, Stanford University School of Medicine, 875 Blake Wilbur Drive, Stanford, CA 94305-5847 (United States)], E-mail: lei@reyes.stanford.edu

    2008-09-07

    The purpose of this work is to develop an effective technique to automatically propagate contours from planning CT to cone beam CT (CBCT) to facilitate CBCT-guided prostate adaptive radiation therapy. Different from other disease sites, such as the lungs, the contour mapping here is complicated by two factors: (i) the physical one-to-one correspondence may not exist due to the insertion or removal of some image contents within the region of interest (ROI); and (ii) reduced contrast to noise ratio of the CBCT images due to increased scatter. To overcome these issues, we investigate a strategy of excluding the regions with variable contents by a careful design of a narrow shell signifying the contour of an ROI. For rectum, for example, a narrow shell with the delineated contours as its interior surface was constructed to avoid the adverse influence of the day-to-day content change inside the rectum on the contour mapping. The corresponding contours in the CBCT were found by warping the narrow shell through the use of BSpline deformable model. Both digital phantom experiments and clinical case testing were carried out to validate the proposed ROI mapping method. It was found that the approach was able to reliably warp the constructed narrow band with an accuracy better than 1.3 mm. For all five clinical cases enrolled in this study, the method yielded satisfactory results even when there were significant rectal content changes between the planning CT and CBCT scans. The overlapped area of the auto-mapped contours over 90% to the manually drawn contours is readily achievable. The proposed approach permits us to take advantage of the regional calculation algorithm yet avoiding the nuisance of rectum/bladder filling and provide a useful tool for adaptive radiotherapy of prostate in the future.

  4. Area of isodensity contours in Gaussian and non-Gaussian fields

    International Nuclear Information System (INIS)

    Ryden, B.S.

    1988-01-01

    The area of isodensity contours in a smoothed density field can be measured by the contour-crossing statistic N1, the number of times per unit length that a line drawn through the density field pierces an isodensity contour. The contour-crossing statistic distinguishes between Gaussian and non-Gaussian fields and provides a measure of the effective slope of the power spectrum. The statistic is easy to apply and can be used on pencil beams and slices as well as on a three-dimensional field. 10 references

  5. Edge and line oriented contour detection : State of the art

    NARCIS (Netherlands)

    Papari, Giuseppe; Petkov, Nicolai

    We present an overview of various edge and line oriented approaches to contour detection that have been proposed in the last two decades. By edge and line oriented we mean methods that do not rely on segmentation. Distinction is made between edges and contours. Contour detectors are divided in local

  6. An investigation into positron emission tomography contouring methods across two treatment planning systems

    International Nuclear Information System (INIS)

    Young, Tony; Som, Seu; Sathiakumar, Chithradevi; Holloway, Lois

    2013-01-01

    Positron emission tomography (PET) imaging has been used to provide additional information regarding patient tumor location, size, and staging for radiotherapy treatment planning purposes. This additional information reduces interobserver variability and produces more consistent contouring. It is well recognized that different contouring methodology for PET data results in different contoured volumes. The goal of this study was to compare the difference in PET contouring methods for 2 different treatment planning systems using a phantom dataset and a series of patient datasets. Contouring methodology was compared on the ADAC Pinnacle Treatment Planning System and the CMS XiO Treatment Planning System. Contours were completed on the phantom and patient datasets using a number of PET contouring methods—the standardized uptake value 2.5 method, 30%, 40%, and 50% of the maximum uptake method and the signal to background ratio method. Differences of >15% were observed for PET-contoured volumes between the different treatment planning systems for the same data and the same PET contouring methodology. Contoured volume differences between treatment planning systems were caused by differences in data formatting and display and the different contouring tools available. Differences in treatment planning system as well as contouring methodology should be considered carefully in dose-volume contouring and reporting, especially between centers that may use different treatment planning systems or those that have several different treatment planning systems

  7. A new template matching method based on contour information

    Science.gov (United States)

    Cai, Huiying; Zhu, Feng; Wu, Qingxiao; Li, Sicong

    2014-11-01

    Template matching is a significant approach in machine vision due to its effectiveness and robustness. However, most of the template matching methods are so time consuming that they can't be used to many real time applications. The closed contour matching method is a popular kind of template matching methods. This paper presents a new closed contour template matching method which is suitable for two dimensional objects. Coarse-to-fine searching strategy is used to improve the matching efficiency and a partial computation elimination scheme is proposed to further speed up the searching process. The method consists of offline model construction and online matching. In the process of model construction, triples and distance image are obtained from the template image. A certain number of triples which are composed by three points are created from the contour information that is extracted from the template image. The rule to select the three points is that the template contour is divided equally into three parts by these points. The distance image is obtained here by distance transform. Each point on the distance image represents the nearest distance between current point and the points on the template contour. During the process of matching, triples of the searching image are created with the same rule as the triples of the model. Through the similarity that is invariant to rotation, translation and scaling between triangles, the triples corresponding to the triples of the model are found. Then we can obtain the initial RST (rotation, translation and scaling) parameters mapping the searching contour to the template contour. In order to speed up the searching process, the points on the searching contour are sampled to reduce the number of the triples. To verify the RST parameters, the searching contour is projected into the distance image, and the mean distance can be computed rapidly by simple operations of addition and multiplication. In the fine searching process

  8. The psychological impact of body contouring surgery

    DEFF Research Database (Denmark)

    Mikkelsen Lorenzen, Mike; Poulsen, Lotte; Poulsen, Signe

    2018-01-01

    INTRODUCTION: Body contouring surgery is associated with changes in body image and identity. The primary aim of the study was to investigate a multidisciplinary assessment of potential psychological challenges before and after body contouring surgery. METHODS: Eight pre- and post-operative patients...... relevant codes had been extracted. RESULTS: A total of seven psychological themes were iden- tified, indicating that surgery alone cannot improve the pa- tients’ psychological difficulties and that psychological care and management of the expected discomfort and body im- age is of considerable importance...... in providing continuity of care. CONCLUSIONS: The reported quality of life is of consider- able importance to patients undergoing body contouring surgery after massive weight loss. Our findings may provide useful information for surgeons and healthcare profes- sionals allowing them to develop patient education...

  9. Contouring algorithm for two dimensional data- an application to airborne surveys

    International Nuclear Information System (INIS)

    Suryakumar, N.V.; Rohatgi, Savita; Raghuwanshi, S.S.

    1994-01-01

    The paper describes in general the contouring algorithm for two dimensional projection of aeroradiometric data and considers not only irregularly spaced flight lines but also solves the other problems related to voluminous data acquired during the airborne surveys. Several simple logics have been described for drawing the contours using scan method and taking care of annotations, identification marking, geographical locations, map size, contour density for visual distinctness and many such problems which may arise during contouring. The present paper also discusses various possibilities of contour line segments in the mini-grid and the criterion for selection of suitable segments has been described in detail. A novel approach to avoid the crossing of contours or missing data is also briefly discussed. The simplicity of the algorithm is mentioned for its ready implementation or any computer/plotter. (author). 8 refs., 8 figs

  10. Visual search of illusory contours: Shape and orientation effects

    Directory of Open Access Journals (Sweden)

    Gvozdenović Vasilije

    2008-01-01

    Full Text Available Illusory contours are specific class of visual stimuli that represent stimuli configurations perceived as integral irrespective of the fact that they are given in fragmented uncompleted wholes. Due to their specific features, illusory contours gained much attention in last decade representing prototype of stimuli used in investigations focused on binding problem. On the other side, investigations of illusory contours are related to problem of the level of their visual processing. Neurophysiologic studies show that processing of illusory contours proceed relatively early, on the V2 level, on the other hand most of experimental studies claim that illusory contours are perceived with engagement of visual attention, binding their elements to whole percept. This research is focused on two experiments in which visual search of illusory contours are based on shape and orientation. The main experimental procedure evolved the task proposed by Bravo and Nakayama where instead of detection, subjects were performing identification of one among two possible targets. In the first experiment subjects detected the presence of illusory square or illusory triangle, while in the second experiment subject were detecting two different orientations of illusory triangle. The results are interpreted in terms of visual search and feature integration theory. Beside the type of visual search task, search type proved to be dependent of specific features of illusory shapes which further complicate theoretical interpretation of the level of their perception.

  11. Predicted risks of radiogenic cardiac toxicity in two pediatric patients undergoing photon or proton radiotherapy

    International Nuclear Information System (INIS)

    Zhang, Rui; Howell, Rebecca M; Homann, Kenneth; Giebeler, Annelise; Taddei, Phillip J; Mahajan, Anita; Newhauser, Wayne D

    2013-01-01

    Hodgkin disease (HD) and medulloblastoma (MB) are common malignancies found in children and young adults, and radiotherapy is part of the standard treatment. It was reported that these patients who received radiation therapy have an increased risk of cardiovascular late effects. We compared the predicted risk of developing radiogenic cardiac toxicity after photon versus proton radiotherapies for a pediatric patient with HD and a pediatric patient with MB. In the treatment plans, each patient’s heart was contoured in fine detail, including substructures of the pericardium and myocardium. Risk calculations took into account both therapeutic and stray radiation doses. We calculated the relative risk (RR) of cardiac toxicity using a linear risk model and the normal tissue complication probability (NTCP) values using relative seriality and Lyman models. Uncertainty analyses were also performed. The RR values of cardiac toxicity for the HD patient were 7.27 (proton) and 8.37 (photon), respectively; the RR values for the MB patient were 1.28 (proton) and 8.39 (photon), respectively. The predicted NTCP values for the HD patient were 2.17% (proton) and 2.67% (photon) for the myocardium, and were 2.11% (proton) and 1.92% (photon) for the whole heart. The predicted ratios of NTCP values (proton/photon) for the MB patient were much less than unity. Uncertainty analyses revealed that the predicted ratio of risk between proton and photon therapies was sensitive to uncertainties in the NTCP model parameters and the mean radiation weighting factor for neutrons, but was not sensitive to heart structure contours. The qualitative findings of the study were not sensitive to uncertainties in these factors. We conclude that proton and photon radiotherapies confer similar predicted risks of cardiac toxicity for the HD patient in this study, and that proton therapy reduced the predicted risk for the MB patient in this study

  12. Holographic Moire Contouring

    Science.gov (United States)

    Sciammarella, C. A.; Sainov, Ventseslav; Simova, Eli

    1990-04-01

    Theoretical analysis and experimental results on holographic moire contouring (HMC) of difussely reflecting objects are presented. The sensitivity and application constraints of the method are discussed. A high signal-to-noise ratio and contrast of the fringes is achieved through the use of high quality silver halide holographic plates HP-650. A good agreement between theoretical and experimental results is observed.

  13. Geometric and Dosimetric Approach to Determine Probability of Late Cardiac Mortality in Left Tangential Breast Irradiation: Comparison Between Wedged Beams and Field-in-Field Technique

    International Nuclear Information System (INIS)

    Pili, Giorgio; Grimaldi, Luca; Fidanza, Christian; Florio, Elena T.; Petruzzelli, Maria F.; D'Errico, Maria P.; De Tommaso, Cristina; Tramacere, Francesco; Musaio, Francesca; Castagna, Roberta; Francavilla, Maria C.; Gianicolo, Emilio A.L.; Portaluri, Maurizio

    2011-01-01

    Purpose: To evaluate the probability of late cardiac mortality resulting from left breast irradiation planned with tangential fields and to compare this probability between the wedged beam and field-in-field (FIF) techniques and to investigate whether some geometric/dosimetric indicators can be determined to estimate the cardiac mortality probability before treatment begins. Methods and Materials: For 30 patients, differential dose-volume histograms were calculated for the wedged beam and FIF plans, and the corresponding cardiac mortality probabilities were determined using the relative seriality model. As a comparative index of the dose distribution uniformity, the planning target volume (PTV) percentages involved in 97-103% of prescribed dose were determined for the two techniques. Three geometric parameters were measured for each patient: the maximal length, indicates how much the heart contours were displaced toward the PTV, the angle subtended at the center of the computed tomography slice by the PTV contour, and the thorax width/thickness ratio. Results: Evaluating the differential dose-volume histograms showed that the gain in uniformity between the two techniques was about 1.5. With the FIF technique, the mean dose sparing for the heart, the left anterior descending coronary artery, and the lung was 15% (2.5 Gy vs. 2.2 Gy), 21% (11.3 Gy vs. 9.0 Gy), and 42% (8.0 Gy vs. 4.6 Gy) respectively, compared with the wedged beam technique. Also, the cardiac mortality probability decreased by 40% (from 0.9% to 0.5%). Three geometric parameters, the maximal length, angle subtended at the center of the computed tomography slice by the PTV contour, and thorax width/thickness ratio, were the determining factors (p = .06 for FIF, and p = .10 for wedged beam) for evaluating the cardiac mortality probability. Conclusion: The FIF technique seemed to yield a lower cardiac mortality probability than the conventional wedged beam technique. However, although our study

  14. A review of methods of analysis in contouring studies for radiation oncology

    International Nuclear Information System (INIS)

    Jameson, Michael G.; Holloway, Lois C.; Metcalfe, Peter E.; Vial, Philip J.; Vinod, Shalini K.

    2010-01-01

    Full text: Inter-observer variability in anatomical contouring is the biggest contributor to uncertainty in radiation treatment planning. Contouring studies are frequently performed to investigate the differences between multiple contours on common datasets. There is, however, no widely accepted method for contour comparisons. The purpose of this study is to review the literature on contouring studies in the context of radiation oncology, with particular consideration of the contouring comparison methods they employ. A literature search, not limited by date, was conducted using Medline and Google Scholar with key words; contour, variation, delineation, inter/intra observer, uncertainty and trial dummy-run. This review includes a description of the contouring processes and contour comparison metrics used. The use of different processes and metrics according to tumour site and other factors were also investigated with limitations described. A total of 69 relevant studies were identified. The most common tumour sites were prostate (26), lung (10), head and neck cancers (8) and breast (7).The most common metric of comparison was volume used 59 times, followed by dimension and shape used 36 times, and centre of volume used 19 times. Of all 69 publications, 67 used a combination of metrics and two used only one metric for comparison. No clear relationships between tumour site or any other factors that may in Auence the contouring process and the metrics used to compare contours were observed from the literature. Further studies are needed to assess the advantages and disadvantages of each metric in various situations.

  15. Subsidence Contours for South Louisiana; UTM 15N NAD83; LRA (2005); [subsidence_contours

    Data.gov (United States)

    Louisiana Geographic Information Center — The GIS data shapefile represents average subsidence contour intervals (0.02 cm/year over 10,000 years) for Coastal LA derived from the following: Kulp, M.A., 2000,...

  16. Effect of current pulsing on tensile properties of titanium alloy

    International Nuclear Information System (INIS)

    Balasubramanian, V.; Jayabalan, V.; Balasubramanian, M.

    2008-01-01

    Titanium and its alloys have been considered as one of the best engineering metals for industrial applications. This is due to the excellent combination of properties such as elevated strength to weight ratio, high toughness, excellent resistance to corrosion and good fatigue properties make them attractive for many industrial applications. Recently, considerable research has been performed on pulsed current gas tungsten arc welding process and reported advantages include improved bead contour, lower heat input requirements, reduced residual stresses and distortion. Metallurgical advantages of pulsed current welding frequently reported in literature include refinement of fusion zone grain size, reduced width of heat affected zone, etc. All these factors will help in improving the mechanical properties. Hence, in this investigation an attempt has been made to study the effect of pulsed current gas tungsten arc welding parameters on Ti-6Al-4V titanium alloy

  17. Effect of current pulsing on tensile properties of titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramanian, V. [Department of Manufacturing Engineering, Annamalai University, Annamalai Nagar 608 002 (India)], E-mail: visvabalu@yahoo.com; Jayabalan, V. [Department of Manufacturing Engineering, Anna University, Guindy, Chennai 600 025 (India)], E-mail: jbalan@annauniv.edu; Balasubramanian, M. [Department of Mechanical Engineering, Maamallan Institute of Technology, Sriperumpudur 602 105 (India)], E-mail: manianmb@rediffmail.com

    2008-07-01

    Titanium and its alloys have been considered as one of the best engineering metals for industrial applications. This is due to the excellent combination of properties such as elevated strength to weight ratio, high toughness, excellent resistance to corrosion and good fatigue properties make them attractive for many industrial applications. Recently, considerable research has been performed on pulsed current gas tungsten arc welding process and reported advantages include improved bead contour, lower heat input requirements, reduced residual stresses and distortion. Metallurgical advantages of pulsed current welding frequently reported in literature include refinement of fusion zone grain size, reduced width of heat affected zone, etc. All these factors will help in improving the mechanical properties. Hence, in this investigation an attempt has been made to study the effect of pulsed current gas tungsten arc welding parameters on Ti-6Al-4V titanium alloy.

  18. Statistical Modeling Approach to Quantitative Analysis of Interobserver Variability in Breast Contouring

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jinzhong, E-mail: jyang4@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Woodward, Wendy A.; Reed, Valerie K.; Strom, Eric A.; Perkins, George H.; Tereffe, Welela; Buchholz, Thomas A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Zhang, Lifei; Balter, Peter; Court, Laurence E. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Dong, Lei [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Scripps Proton Therapy Center, San Diego, California (United States)

    2014-05-01

    Purpose: To develop a new approach for interobserver variability analysis. Methods and Materials: Eight radiation oncologists specializing in breast cancer radiation therapy delineated a patient's left breast “from scratch” and from a template that was generated using deformable image registration. Three of the radiation oncologists had previously received training in Radiation Therapy Oncology Group consensus contouring for breast cancer atlas. The simultaneous truth and performance level estimation algorithm was applied to the 8 contours delineated “from scratch” to produce a group consensus contour. Individual Jaccard scores were fitted to a beta distribution model. We also applied this analysis to 2 or more patients, which were contoured by 9 breast radiation oncologists from 8 institutions. Results: The beta distribution model had a mean of 86.2%, standard deviation (SD) of ±5.9%, a skewness of −0.7, and excess kurtosis of 0.55, exemplifying broad interobserver variability. The 3 RTOG-trained physicians had higher agreement scores than average, indicating that their contours were close to the group consensus contour. One physician had high sensitivity but lower specificity than the others, which implies that this physician tended to contour a structure larger than those of the others. Two other physicians had low sensitivity but specificity similar to the others, which implies that they tended to contour a structure smaller than the others. With this information, they could adjust their contouring practice to be more consistent with others if desired. When contouring from the template, the beta distribution model had a mean of 92.3%, SD ± 3.4%, skewness of −0.79, and excess kurtosis of 0.83, which indicated a much better consistency among individual contours. Similar results were obtained for the analysis of 2 additional patients. Conclusions: The proposed statistical approach was able to measure interobserver variability quantitatively

  19. [Cardiac Synchronization Function Estimation Based on ASM Level Set Segmentation Method].

    Science.gov (United States)

    Zhang, Yaonan; Gao, Yuan; Tang, Liang; He, Ying; Zhang, Huie

    At present, there is no accurate and quantitative methods for the determination of cardiac mechanical synchronism, and quantitative determination of the synchronization function of the four cardiac cavities with medical images has a great clinical value. This paper uses the whole heart ultrasound image sequence, and segments the left & right atriums and left & right ventricles of each frame. After the segmentation, the number of pixels in each cavity and in each frame is recorded, and the areas of the four cavities of the image sequence are therefore obtained. The area change curves of the four cavities are further extracted, and the synchronous information of the four cavities is obtained. Because of the low SNR of Ultrasound images, the boundary lines of cardiac cavities are vague, so the extraction of cardiac contours is still a challenging problem. Therefore, the ASM model information is added to the traditional level set method to force the curve evolution process. According to the experimental results, the improved method improves the accuracy of the segmentation. Furthermore, based on the ventricular segmentation, the right and left ventricular systolic functions are evaluated, mainly according to the area changes. The synchronization of the four cavities of the heart is estimated based on the area changes and the volume changes.

  20. Cardiac tissue engineering

    Directory of Open Access Journals (Sweden)

    MILICA RADISIC

    2005-03-01

    Full Text Available We hypothesized that clinically sized (1-5 mm thick,compact cardiac constructs containing physiologically high density of viable cells (~108 cells/cm3 can be engineered in vitro by using biomimetic culture systems capable of providing oxygen transport and electrical stimulation, designed to mimic those in native heart. This hypothesis was tested by culturing rat heart cells on polymer scaffolds, either with perfusion of culture medium (physiologic interstitial velocity, supplementation of perfluorocarbons, or with electrical stimulation (continuous application of biphasic pulses, 2 ms, 5 V, 1 Hz. Tissue constructs cultured without perfusion or electrical stimulation served as controls. Medium perfusion and addition of perfluorocarbons resulted in compact, thick constructs containing physiologic density of viable, electromechanically coupled cells, in contrast to control constructs which had only a ~100 mm thick peripheral region with functionally connected cells. Electrical stimulation of cultured constructs resulted in markedly improved contractile properties, increased amounts of cardiac proteins, and remarkably well developed ultrastructure (similar to that of native heart as compared to non-stimulated controls. We discuss here the state of the art of cardiac tissue engineering, in light of the biomimetic approach that reproduces in vitro some of the conditions present during normal tissue development.

  1. Brightness/darkness induction and the genesis of a contour

    Directory of Open Access Journals (Sweden)

    Sergio eRoncato

    2014-10-01

    Full Text Available Visual contours often result from the integration or interpolation of fragmented edges.The strength of the completion increases when the edges share the same contrast polarity (CP. Here we demonstrate that the appearance in the perceptual field of this integrated unit, or contour of invariant CP, is concomitant with a vivid brightness alteration of the surfaces at its opposite sides. To observe this effect requires some stratagems because the formation in the visual field of a contour of invariant CP normally engenders the formation of a second contour and then the rise of two streams of induction signals that interfere in different ways. Particular configurations have been introduced that allow us to observe the induction effects of one contour taken in isolation. I documented these effects by phenomenological observations and psychophysical measurement of the brightness alteration in relation to luminance contrast. When the edges of the same CP complete to form a contour, the background of homogeneous luminance appears to dim at one side and to brighten at the opposite side (in accord with the CP. The strength of the phenomenon is proportional to the local luminance contrast. This effect weakens or nulls when the contour of the invariant CP separates surfaces filled with different grey shades.These conflicting results stimulate a deeper exploration of the induction phenomena and their role in the computation of brightness contrast. An alternative perspective is offered to account for some brightness illusions and their relation to the phenomenal transparency. The main assumption asserts that, when in the same region induction signals of opposite CP overlap, the filling-in are blocked unless the image is stratified into different layers, one for each signal of the same polarity. Phenomenological observations document this solution by the visual system

  2. Color contributes to object-contour perception in natural scenes.

    Science.gov (United States)

    Hansen, Thorsten; Gegenfurtner, Karl R

    2017-03-01

    The magnitudes of chromatic and achromatic edge contrast are statistically independent and thus provide independent information, which can be used for object-contour perception. However, it is unclear if and how much object-contour perception benefits from chromatic edge contrast. To address this question, we investigated how well human-marked object contours can be predicted from achromatic and chromatic edge contrast. We used four data sets of human-marked object contours with a total of 824 images. We converted the images to the Derrington-Krauskopf-Lennie color space to separate chromatic from achromatic information in a physiologically meaningful way. Edges were detected in the three dimensions of the color space (one achromatic and two chromatic) and compared to human-marked object contours using receiver operating-characteristic (ROC) analysis for a threshold-independent evaluation. Performance was quantified by the difference of the area under the ROC curves (ΔAUC). Results were consistent across different data sets and edge-detection methods. If chromatic edges were used in addition to achromatic edges, predictions were better for 83% of the images, with a prediction advantage of 3.5% ΔAUC, averaged across all data sets and edge detectors. For some images the prediction advantage was considerably higher, up to 52% ΔAUC. Interestingly, if achromatic edges were used in addition to chromatic edges, the average prediction advantage was smaller (2.4% ΔAUC). We interpret our results such that chromatic information is important for object-contour perception.

  3. Parallel peak pruning for scalable SMP contour tree computation

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Hamish A. [Univ. of Leeds (United Kingdom); Weber, Gunther H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Davis, CA (United States); Sewell, Christopher M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ahrens, James P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-09

    As data sets grow to exascale, automated data analysis and visualisation are increasingly important, to intermediate human understanding and to reduce demands on disk storage via in situ analysis. Trends in architecture of high performance computing systems necessitate analysis algorithms to make effective use of combinations of massively multicore and distributed systems. One of the principal analytic tools is the contour tree, which analyses relationships between contours to identify features of more than local importance. Unfortunately, the predominant algorithms for computing the contour tree are explicitly serial, and founded on serial metaphors, which has limited the scalability of this form of analysis. While there is some work on distributed contour tree computation, and separately on hybrid GPU-CPU computation, there is no efficient algorithm with strong formal guarantees on performance allied with fast practical performance. Here in this paper, we report the first shared SMP algorithm for fully parallel contour tree computation, withfor-mal guarantees of O(lgnlgt) parallel steps and O(n lgn) work, and implementations with up to 10x parallel speed up in OpenMP and up to 50x speed up in NVIDIA Thrust.

  4. Max dD/Dt: A Novel Parameter to Assess Fetal Cardiac Contractility and a Substitute for Max dP/Dt.

    Science.gov (United States)

    Fujita, Yasuyuki; Kiyokoba, Ryo; Yumoto, Yasuo; Kato, Kiyoko

    2018-07-01

    Aortic pulse waveforms are composed of a forward wave from the heart and a reflection wave from the periphery. We focused on this forward wave and suggested a new parameter, the maximum slope of aortic pulse waveforms (max dD/dt), for fetal cardiac contractility. Max dD/dt was calculated from fetal aortic pulse waveforms recorded with an echo-tracking system. A normal range of max dD/dt was constructed in 105 healthy fetuses using linear regression analysis. Twenty-two fetuses with suspected fetal cardiac dysfunction were divided into normal and decreased max dD/dt groups, and their clinical parameters were compared. Max dD/dt of aortic pulse waveforms increased linearly with advancing gestational age (r = 0.93). The decreased max dD/dt was associated with abnormal cardiotocography findings and short- and long-term prognosis. In conclusion, max dD/dt calculated from the aortic pulse waveforms in fetuses can substitute for max dP/dt, an index of cardiac contractility in adults. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  5. Deformation of contour and Hawking temperature

    International Nuclear Information System (INIS)

    Ding Chikun; Jing Jiliang

    2010-01-01

    It was found that, in an isotropic coordinate system, the tunneling approach brings a factor of 1/2 for the Hawking temperature of a Schwarzschild black hole. In this paper, we address this kind of problem by studying the relation between the Hawking temperature and the deformation of the integral contour for the scalar and Dirac particles tunneling. We find that the correct Hawking temperature can be obtained exactly as long as the integral contour deformed corresponding to the radial coordinate transform if the transformation is a non-regular or zero function at the event horizon.

  6. Color and Contour Based Identification of Stem of Coconut Bunch

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Manoharan, Sakthiprasad K.; Reddy, Rajesh G.; Sriteja, Gone; Kashyap, Ashwin

    2017-08-01

    Vision is the key component of Artificial Intelligence and Automated Robotics. Sensors or Cameras are the sight organs for a robot. Only through this, they are able to locate themselves or identify the shape of a regular or an irregular object. This paper presents the method of Identification of an object based on color and contour recognition using a camera through digital image processing techniques for robotic applications. In order to identify the contour, shape matching technique is used, which takes the input data from the database provided, and uses it to identify the contour by checking for shape match. The shape match is based on the idea of iterating through each contour of the threshold image. The color is identified on HSV Scale, by approximating the desired range of values from the database. HSV data along with iteration is used for identifying a quadrilateral, which is our required contour. This algorithm could also be used in a non-deterministic plane, which only uses HSV values exclusively.

  7. Some distinguishing characteristics of contour and texture phenomena in images

    Science.gov (United States)

    Jobson, Daniel J.

    1992-01-01

    The development of generalized contour/texture discrimination techniques is a central element necessary for machine vision recognition and interpretation of arbitrary images. Here, the visual perception of texture, selected studies of texture analysis in machine vision, and diverse small samples of contour and texture are all used to provide insights into the fundamental characteristics of contour and texture. From these, an experimental discrimination scheme is developed and tested on a battery of natural images. The visual perception of texture defined fine texture as a subclass which is interpreted as shading and is distinct from coarse figural similarity textures. Also, perception defined the smallest scale for contour/texture discrimination as eight to nine visual acuity units. Three contour/texture discrimination parameters were found to be moderately successful for this scale discrimination: (1) lightness change in a blurred version of the image, (2) change in lightness change in the original image, and (3) percent change in edge counts relative to local maximum.

  8. Automatic programming of grinding robot restoration of contours

    OpenAIRE

    Are Willersrud; Fred Godtliebsen; Trygve Thomessen

    1995-01-01

    A new programming method has been developed for grinding robots. Instead of using the conventional jog-and-teach method, the workpiece contour is automatically tracked by the robot. During the tracking, the robot position is stored in the robot control system every 8th millisecond. After filtering and reducing this contour data, a robot program is automatically generated.

  9. Object segmentation using graph cuts and active contours in a pyramidal framework

    Science.gov (United States)

    Subudhi, Priyambada; Mukhopadhyay, Susanta

    2018-03-01

    Graph cuts and active contours are two very popular interactive object segmentation techniques in the field of computer vision and image processing. However, both these approaches have their own well-known limitations. Graph cut methods perform efficiently giving global optimal segmentation result for smaller images. However, for larger images, huge graphs need to be constructed which not only takes an unacceptable amount of memory but also increases the time required for segmentation to a great extent. On the other hand, in case of active contours, initial contour selection plays an important role in the accuracy of the segmentation. So a proper selection of initial contour may improve the complexity as well as the accuracy of the result. In this paper, we have tried to combine these two approaches to overcome their above-mentioned drawbacks and develop a fast technique of object segmentation. Here, we have used a pyramidal framework and applied the mincut/maxflow algorithm on the lowest resolution image with the least number of seed points possible which will be very fast due to the smaller size of the image. Then, the obtained segmentation contour is super-sampled and and worked as the initial contour for the next higher resolution image. As the initial contour is very close to the actual contour, so fewer number of iterations will be required for the convergence of the contour. The process is repeated for all the high-resolution images and experimental results show that our approach is faster as well as memory efficient as compare to both graph cut or active contour segmentation alone.

  10. Perceptual representation and effectiveness of local figure?ground cues in natural contours

    OpenAIRE

    Sakai, Ko; Matsuoka, Shouhei; Kurematsu, Ken; Hatori, Yasuhiro

    2015-01-01

    A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure–ground segregation. Although previous studies have reported local contour features that evoke figure–ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural cont...

  11. Comparison of Regression Analysis and Transfer Function in Estimating the Parameters of Central Pulse Waves from Brachial Pulse Wave.

    Science.gov (United States)

    Chai, Rui; Xu, Li-Sheng; Yao, Yang; Hao, Li-Ling; Qi, Lin

    2017-01-01

    This study analyzed ascending branch slope (A_slope), dicrotic notch height (Hn), diastolic area (Ad) and systolic area (As) diastolic blood pressure (DBP), systolic blood pressure (SBP), pulse pressure (PP), subendocardial viability ratio (SEVR), waveform parameter (k), stroke volume (SV), cardiac output (CO), and peripheral resistance (RS) of central pulse wave invasively and non-invasively measured. Invasively measured parameters were compared with parameters measured from brachial pulse waves by regression model and transfer function model. Accuracy of parameters estimated by regression and transfer function model, was compared too. Findings showed that k value, central pulse wave and brachial pulse wave parameters invasively measured, correlated positively. Regression model parameters including A_slope, DBP, SEVR, and transfer function model parameters had good consistency with parameters invasively measured. They had same effect of consistency. SBP, PP, SV, and CO could be calculated through the regression model, but their accuracies were worse than that of transfer function model.

  12. Consensus Recommendations for Radiation Therapy Contouring and Treatment of Vulvar Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, David K., E-mail: david.gaffney@hci.utah.edu [Department of Radiation Oncology, Huntsman Cancer Hospital, Salt Lake City, Utah (United States); King, Bronwyn [Department of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre and Epworth Radiation Oncology, Melbourne, Victoria (Australia); Viswanathan, Akila N. [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center, Harvard Medical School, Boston, Massachusetts (United States); Barkati, Maroie [Department of Radiation Oncology, Centre hospitalier de l' universite de Montreal, Montreal, Quebec (Canada); Beriwal, Sushil [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Eifel, Patricia [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); Erickson, Beth [Department of Radiation Oncology, Proedtert and Medical College Clinical Cancer Center, Milwaukee, Wisconsin (United States); Fyles, Anthony [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Goulart, Jennifer [Department of Radiation Oncology, British Columbia Cancer Agency, Victoria, British Columbia (Canada); Harkenrider, Matthew [Department of Radiation Oncology, Stritch School of Medicine, Loyola University, Maywood, Illinois (United States); Jhingran, Anuja; Klopp, Ann [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); Koh, Wui-Jin [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Lim, Karen [Liverpool Cancer Therapy Centre, Radiation Oncology Unit, Sydney, New South Wales (Australia); Petersen, Ivy [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Portelance, Lorraine [Radiation Oncology Department, Miller School of Medicine, University of Miami, Miami, Florida (United States); and others

    2016-07-15

    Purpose: The purpose of this study was to develop a radiation therapy (RT) contouring atlas and recommendations for women with postoperative and locally advanced vulvar carcinoma. Methods and Materials: An international committee of 35 expert gynecologic radiation oncologists completed a survey of the treatment of vulvar carcinoma. An initial set of recommendations for contouring was discussed and generated by consensus. Two cases, 1 locally advanced and 1 postoperative, were contoured by 14 physicians. Contours were compared and analyzed using an expectation-maximization algorithm for simultaneous truth and performance level estimation (STAPLE), and a 95% confidence interval contour was developed. The level of agreement among contours was assessed using a kappa statistic. STAPLE contours underwent full committee editing to generate the final atlas consensus contours. Results: Analysis of the 14 contours showed substantial agreement, with kappa statistics of 0.69 and 0.64 for cases 1 and 2, respectively. There was high specificity for both cases (≥99%) and only moderate sensitivity of 71.3% and 64.9% for cases 1 and 2, respectively. Expert review and discussion generated consensus recommendations for contouring target volumes and treatment for postoperative and locally advanced vulvar cancer. Conclusions: These consensus recommendations for contouring and treatment of vulvar cancer identified areas of complexity and controversy. Given the lack of clinical research evidence in vulvar cancer radiation therapy, the committee advocates a conservative and consistent approach using standardized recommendations.

  13. Consensus Recommendations for Radiation Therapy Contouring and Treatment of Vulvar Carcinoma

    International Nuclear Information System (INIS)

    Gaffney, David K.; King, Bronwyn; Viswanathan, Akila N.; Barkati, Maroie; Beriwal, Sushil; Eifel, Patricia; Erickson, Beth; Fyles, Anthony; Goulart, Jennifer; Harkenrider, Matthew; Jhingran, Anuja; Klopp, Ann; Koh, Wui-Jin; Lim, Karen; Petersen, Ivy; Portelance, Lorraine

    2016-01-01

    Purpose: The purpose of this study was to develop a radiation therapy (RT) contouring atlas and recommendations for women with postoperative and locally advanced vulvar carcinoma. Methods and Materials: An international committee of 35 expert gynecologic radiation oncologists completed a survey of the treatment of vulvar carcinoma. An initial set of recommendations for contouring was discussed and generated by consensus. Two cases, 1 locally advanced and 1 postoperative, were contoured by 14 physicians. Contours were compared and analyzed using an expectation-maximization algorithm for simultaneous truth and performance level estimation (STAPLE), and a 95% confidence interval contour was developed. The level of agreement among contours was assessed using a kappa statistic. STAPLE contours underwent full committee editing to generate the final atlas consensus contours. Results: Analysis of the 14 contours showed substantial agreement, with kappa statistics of 0.69 and 0.64 for cases 1 and 2, respectively. There was high specificity for both cases (≥99%) and only moderate sensitivity of 71.3% and 64.9% for cases 1 and 2, respectively. Expert review and discussion generated consensus recommendations for contouring target volumes and treatment for postoperative and locally advanced vulvar cancer. Conclusions: These consensus recommendations for contouring and treatment of vulvar cancer identified areas of complexity and controversy. Given the lack of clinical research evidence in vulvar cancer radiation therapy, the committee advocates a conservative and consistent approach using standardized recommendations.

  14. Automatic programming of grinding robot restoration of contours

    Directory of Open Access Journals (Sweden)

    Are Willersrud

    1995-07-01

    Full Text Available A new programming method has been developed for grinding robots. Instead of using the conventional jog-and-teach method, the workpiece contour is automatically tracked by the robot. During the tracking, the robot position is stored in the robot control system every 8th millisecond. After filtering and reducing this contour data, a robot program is automatically generated.

  15. Time-dependent plasma behavior triggered by a pulsed electron gun under conditions of beam-plasma-discharge

    International Nuclear Information System (INIS)

    Szuszczewicz, E.P.; Lin, C.S.

    1982-01-01

    This chapter reports on experiments whose purpose was to simulate spaceborne applications of energetic electron guns while exploring the ''in situ'' diagnostics of time-dependent beam-plasma behavior under pulsed electron gun conditions. Beam-plasma-discharge (BPD), the BPD afterglow that exists after gun-pulse termination, and the plasma decay process are considered. It is concluded that there is a rapid enhancement in plasma density as the gas turns on; that during the pulse-ON time a quasi-steady-state BPD can be maintained with characteristics identical with its dc counterpart; that in the period immediately following gun-pulse termination the plasma loss process is dominated by cross-field radial diffusion; and that the afterglow plasma is within + or -10% of being an isodensity contour

  16. Semi-automated contour recognition using DICOMautomaton

    International Nuclear Information System (INIS)

    Clark, H; Duzenli, C; Wu, J; Moiseenko, V; Lee, R; Gill, B; Thomas, S

    2014-01-01

    Purpose: A system has been developed which recognizes and classifies Digital Imaging and Communication in Medicine contour data with minimal human intervention. It allows researchers to overcome obstacles which tax analysis and mining systems, including inconsistent naming conventions and differences in data age or resolution. Methods: Lexicographic and geometric analysis is used for recognition. Well-known lexicographic methods implemented include Levenshtein-Damerau, bag-of-characters, Double Metaphone, Soundex, and (word and character)-N-grams. Geometrical implementations include 3D Fourier Descriptors, probability spheres, boolean overlap, simple feature comparison (e.g. eccentricity, volume) and rule-based techniques. Both analyses implement custom, domain-specific modules (e.g. emphasis differentiating left/right organ variants). Contour labels from 60 head and neck patients are used for cross-validation. Results: Mixed-lexicographical methods show an effective improvement in more than 10% of recognition attempts compared with a pure Levenshtein-Damerau approach when withholding 70% of the lexicon. Domain-specific and geometrical techniques further boost performance. Conclusions: DICOMautomaton allows users to recognize contours semi-automatically. As usage increases and the lexicon is filled with additional structures, performance improves, increasing the overall utility of the system.

  17. MAP Estimation of Chin and Cheek Contours in Video Sequences

    Directory of Open Access Journals (Sweden)

    Kampmann Markus

    2004-01-01

    Full Text Available An algorithm for the estimation of chin and cheek contours in video sequences is proposed. This algorithm exploits a priori knowledge about shape and position of chin and cheek contours in images. Exploiting knowledge about the shape, a parametric 2D model representing chin and cheek contours is introduced. Exploiting knowledge about the position, a MAP estimator is developed taking into account the observed luminance gradient as well as a priori probabilities of chin and cheek contours positions. The proposed algorithm was tested with head and shoulder video sequences (image resolution CIF. In nearly 70% of all investigated video frames, a subjectively error free estimation could be achieved. The 2D estimate error is measured as on average between 2.4 and .

  18. Technology assessment of automated atlas based segmentation in prostate bed contouring

    Directory of Open Access Journals (Sweden)

    Sexton Tracy

    2011-09-01

    Full Text Available Abstract Background Prostate bed (PB contouring is time consuming and associated with inter-observer variability. We evaluated an automated atlas-based segmentation (AABS engine in its potential to reduce contouring time and inter-observer variability. Methods An atlas builder (AB manually contoured the prostate bed, rectum, left femoral head (LFH, right femoral head (RFH, bladder, and penile bulb of 75 post-prostatectomy cases to create an atlas according to the recent RTOG guidelines. 5 other Radiation Oncologists (RO and the AABS contoured 5 new cases. A STAPLE contour for each of the 5 patients was generated. All contours were anonymized and sent back to the 5 RO to be edited as clinically necessary. All contouring times were recorded. The dice similarity coefficient (DSC was used to evaluate the unedited- and edited- AABS and inter-observer variability among the RO. Descriptive statistics, paired t-tests and a Pearson correlation were performed. ANOVA analysis using logit transformations of DSC values was calculated to assess inter-observer variability. Results The mean time for manual contours and AABS was 17.5- and 14.1 minutes respectively (p = 0.003. The DSC results (mean, SD for the comparison of the unedited-AABS versus STAPLE contours for the PB (0.48, 0.17, bladder (0.67, 0.19, LFH (0.92, 0.01, RFH (0.92, 0.01, penile bulb (0.33, 0.25 and rectum (0.59, 0.11. The DSC results (mean, SD for the comparison of the edited-AABS versus STAPLE contours for the PB (0.67, 0.19, bladder (0.88, 0.13, LFH (0.93, 0.01, RFH (0.92, 0.01, penile bulb (0.54, 0.21 and rectum (0.78, 0.12. The DSC results (mean, SD for the comparison of the edited-AABS versus the expert panel for the PB (0.47, 0.16, bladder (0.67, 0.18, LFH (0.83, 0.18, RFH (0.83, 0.17, penile bulb (0.31, 0.23 and rectum (0.58, 0.09. The DSC results (mean, SD for the comparison of the STAPLE contours and the 5 RO are PB (0.78, 0.15, bladder (0.96, 0.02, left femoral head (0.87, 0

  19. Automatic Construction by Contour Crafting Technology

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Khorramshahi

    2017-07-01

    Full Text Available Contour Crafting is a novel technology in construction industry based on 3D printing that uses robotics to construct free form building structures by repeatedly laying down layers of material such as concrete. It is actually an approach to scale up automatic fabrication from building small industrial parts to constructing buildings. However, there are little information about contour crafting (CC in current use; present paper aims to describe the operational steps of creating a whole building by the machine reviewing relevant literature. Furthermore, it will represent the advantages of CC usage compared to traditional construction methods, as well as its applicability in construction industry.

  20. Regression analysis and transfer function in estimating the parameters of central pulse waves from brachial pulse wave.

    Science.gov (United States)

    Chai Rui; Li Si-Man; Xu Li-Sheng; Yao Yang; Hao Li-Ling

    2017-07-01

    This study mainly analyzed the parameters such as ascending branch slope (A_slope), dicrotic notch height (Hn), diastolic area (Ad) and systolic area (As) diastolic blood pressure (DBP), systolic blood pressure (SBP), pulse pressure (PP), subendocardial viability ratio (SEVR), waveform parameter (k), stroke volume (SV), cardiac output (CO) and peripheral resistance (RS) of central pulse wave invasively and non-invasively measured. These parameters extracted from the central pulse wave invasively measured were compared with the parameters measured from the brachial pulse waves by a regression model and a transfer function model. The accuracy of the parameters which were estimated by the regression model and the transfer function model was compared too. Our findings showed that in addition to the k value, the above parameters of the central pulse wave and the brachial pulse wave invasively measured had positive correlation. Both the regression model parameters including A_slope, DBP, SEVR and the transfer function model parameters had good consistency with the parameters invasively measured, and they had the same effect of consistency. The regression equations of the three parameters were expressed by Y'=a+bx. The SBP, PP, SV, CO of central pulse wave could be calculated through the regression model, but their accuracies were worse than that of transfer function model.

  1. Computer assisted holographic moire contouring

    Science.gov (United States)

    Sciammarella, Cesar A.

    2000-01-01

    Theoretical analyses and experimental results on holographic moire contouring on diffusely reflecting objects are presented. The sensitivity and limitations of the method are discussed. Particular emphasis is put on computer-assisted data retrieval, processing, and recording.

  2. Sacral Neuromodulation in Patients With a Cardiac Pacemaker

    Directory of Open Access Journals (Sweden)

    Abdullah A. Gahzi

    2016-09-01

    Full Text Available The objective of this study was to describe our experience using sacral neuromodulation to treat urinary urgency, frequency, urge incontinence, and chronic urinary retention in patients with cardiac pacemakers. With the increasingly widespread use of InterStim for bladder function restoration, we are seeing more complex patients with multiple comorbidities, including cardiac conditions. Herein, we report 3 cases of individuals with cardiac pacemakers who underwent InterStim implantation to treat urinary conditions. This study is a case series of 3 patients with cardiac pacemakers who underwent sacral neuromodulation to treat refractory voiding dysfunction. The initial patient screening for InterStim therapy involved percutaneous nerve evaluation (PNE, in which a temporary untined lead wire was placed through the S3 foramen. Patients who did not respond to PNE proceeded to a staged implant. All patients in this study had a greater than 50% improvement of their urinary symptoms during the initial trial and underwent placement of the InterStim implantable pulse generator (IPG. Postoperative programming was done under electrocardiogram monitoring by a cardiologist. No interference was observed between the Inter-Stim IPG and the cardiac pacemaker. In this group of patients, sacral neuromodulation in the presence of a cardiac pacemaker appears to have been safe.

  3. Spinal cord motion. Influence of respiration and cardiac cycle

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, S. [RWTH Aachen University Hospital (Germany). Dept. of Neuroradiology; University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; Schoth, F. [RWTH Aachen University Hospital (Germany). Dept. of Diagnostic Radiology; Stolzmann, P. [University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; Krings, T. [Toronto Western Hospital, ON (Canada). Div. of Neuroradiology; Mull, M.; Wiesmann, M. [RWTH Aachen University Hospital (Germany). Dept. of Neuroradiology; Stracke, C.P. [RWTH Aachen University Hospital (Germany). Dept. of Neuroradiology; Alfried-Krupp-Hospital, Essen (Germany). Dept. of Neuroradiology

    2014-11-15

    To assess physiological spinal cord motion during the cardiac cycle compared with the influence of respiration based on magnetic resonance imaging (MRI) measurements. Anterior-posterior spinal cord motion within the spinal canal was assessed in 16 healthy volunteers (median age, 25 years) by cardiac-triggered and cardiac-gated gradient echo pulse sequence MRI. Image acquisition was performed during breath-holding, normal breathing, and forced breathing. Normal spinal cord motion values were computed using descriptive statistics. Breathing-dependent differences were assessed using the Wilcoxon signed-rank test and compared with the cardiac-based cord motion. A normal value table was set up for the spinal cord motion of each vertebral cervico-thoracic-lumbar segment. Significant differences in cord motion were found between cardiac-based motion while breath-holding and the two breathing modalities (P < 0.01 each). Spinal cord motion was found to be highest during forced breathing, with a maximum in the lower cervical spinal segments (C5; mean, 2.1 mm ± 1.17). Image acquisition during breath-holding revealed the lowest motion. MRI permits the demonstration and evaluation of cardiac and respiration-dependent spinal cord motion within the spinal canal from the cervical to lumbar segments. Breathing conditions have a considerably greater impact than cardiac activity on spinal cord motion.

  4. Spinal cord motion. Influence of respiration and cardiac cycle

    International Nuclear Information System (INIS)

    Winklhofer, S.; University Hospital Zurich; Schoth, F.; Stolzmann, P.; Krings, T.; Mull, M.; Wiesmann, M.; Stracke, C.P.; Alfried-Krupp-Hospital, Essen

    2014-01-01

    To assess physiological spinal cord motion during the cardiac cycle compared with the influence of respiration based on magnetic resonance imaging (MRI) measurements. Anterior-posterior spinal cord motion within the spinal canal was assessed in 16 healthy volunteers (median age, 25 years) by cardiac-triggered and cardiac-gated gradient echo pulse sequence MRI. Image acquisition was performed during breath-holding, normal breathing, and forced breathing. Normal spinal cord motion values were computed using descriptive statistics. Breathing-dependent differences were assessed using the Wilcoxon signed-rank test and compared with the cardiac-based cord motion. A normal value table was set up for the spinal cord motion of each vertebral cervico-thoracic-lumbar segment. Significant differences in cord motion were found between cardiac-based motion while breath-holding and the two breathing modalities (P < 0.01 each). Spinal cord motion was found to be highest during forced breathing, with a maximum in the lower cervical spinal segments (C5; mean, 2.1 mm ± 1.17). Image acquisition during breath-holding revealed the lowest motion. MRI permits the demonstration and evaluation of cardiac and respiration-dependent spinal cord motion within the spinal canal from the cervical to lumbar segments. Breathing conditions have a considerably greater impact than cardiac activity on spinal cord motion.

  5. Global regularizing flows with topology preservation for active contours and polygons.

    Science.gov (United States)

    Sundaramoorthi, Ganesh; Yezzi, Anthony

    2007-03-01

    Active contour and active polygon models have been used widely for image segmentation. In some applications, the topology of the object(s) to be detected from an image is known a priori, despite a complex unknown geometry, and it is important that the active contour or polygon maintain the desired topology. In this work, we construct a novel geometric flow that can be added to image-based evolutions of active contours and polygons in order to preserve the topology of the initial contour or polygon. We emphasize that, unlike other methods for topology preservation, the proposed geometric flow continually adjusts the geometry of the original evolution in a gradual and graceful manner so as to prevent a topology change long before the curve or polygon becomes close to topology change. The flow also serves as a global regularity term for the evolving contour, and has smoothness properties similar to curvature flow. These properties of gradually adjusting the original flow and global regularization prevent geometrical inaccuracies common with simple discrete topology preservation schemes. The proposed topology preserving geometric flow is the gradient flow arising from an energy that is based on electrostatic principles. The evolution of a single point on the contour depends on all other points of the contour, which is different from traditional curve evolutions in the computer vision literature.

  6. [Leisure-time sport activities and cardiac outpatient therapy in coronary patients].

    Science.gov (United States)

    Heitkamp, Hans-Christian; Schimpf, Thomas M; Hipp, Arno; Niess, Andreas

    2005-03-01

    Exercise intensity in coronary patients is controlled by heart rate measurements. Very few investigations have compared the maximum heart rate in cardiac outpatient groups, in leisure-time sport activities, and especially in swimming. Within different exercise conditions 21 coronary patients, nine in well-compensated cardiac condition joining a training group and twelve joining the exercise group with lower intensity, without signs of heart failure, engaged in an incremental bicycle ergometry. A six-lead ECG was derived at the same time with a 24-h ECG. The performance tolerance was measured by the pulse limit derived in 20 patients; one patient failed to show signs of subjective or objective ischemia. During a 24-h ECG monitoring, the patients took part in a 1-h standardized cardiac outpatient program, a standardized swimming program 4 x 25 m, and a typical self-selected leisure-time activity. The patients showed a peak work capacity of 2.2 W/kg and a symptom-free work capacity of 1.3 W/kg. The derived upper heart rate limit was passed during swimming by 19, during leisure-time activity by 16, and during cardiac outpatient program by two patients. The maximum of the mean overriding the limit occurred in leisure-time activity. Signs of ischemia occurred during ergometry in 15, during swimming training in ten patients, during leisure-time activity in eight, and during cardiac outpatient therapy in one. Arrhythmia leisure-time sport activity in 15, during cardiac outpatient therapy in 17, and during swimming in eight patients. Arrhythmia Lown IVa occurred in one patient each during ergometry, leisure sports, and during the night. Coronary patients are in danger to exercise beyond the pulse limit during swimming and other leisure-time sports and not during cardiac outpatient therapy. The upper heart rate limit should be observed during swimming and other endurance leisure-time activities, and is of little importance during cardiac outpatient therapy.

  7. SU-E-J-108: Solving the Chinese Postman Problem for Effective Contour Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J; Zhang, L; Balter, P; Court, L [MD Anderson Cancer Center, Houston, TX (United States); Zhang, Y; Dong, L [Scripps Proton Therapy Center, San Diego, CA (United States)

    2015-06-15

    Purpose: To develop a practical approach for accurate contour deformation when deformable image registration (DIR) is used for atlas-based segmentation or contour propagation in image-guided radiotherapy. Methods: A contour deformation approach was developed on the basis of 3D mesh operations. The 2D contours represented by a series of points in each slice were first converted to a 3D triangular mesh, which was deformed by the deformation vectors resulting from DIR. A set of parallel 2D planes then cut through the deformed 3D mesh, generating unordered points and line segments, which should be reorganized into a set of 2D contour points. It was realized that the reorganization problem was equivalent to solving the Chinese Postman Problem (CPP) by traversing a graph built from the unordered points with the least cost. Alternatively, deformation could be applied to a binary mask converted from the original contours. The deformed binary mask was then converted back into contours at the CT slice locations. We performed a qualitative comparison to validate the mesh-based approach against the image-based approach. Results: The DIR could considerably change the 3D mesh, making complicated 2D contour representations after deformation. CPP was able to effectively reorganize the points in 2D planes no matter how complicated the 2D contours were. The mesh-based approach did not require a post-processing of the contour, thus accurately showing the actual deformation in DIR. The mesh-based approach could keep some fine details and resulted in smoother contours than the image-based approach did, especially for the lung structure. Image-based approach appeared to over-process contours and suffered from image resolution limits. The mesh-based approach was integrated into in-house DIR software for use in routine clinic and research. Conclusion: We developed a practical approach for accurate contour deformation. The efficiency of this approach was demonstrated in both clinic and

  8. USGS Elevation Contours Overlay Map Service from The National Map

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The USGS Elevation Contours service from The National Map (TNM) consists of contours generated for the conterminous United States from 1- and 1/3 arc-second...

  9. A Neurocomputational Account of the Role of Contour Facilitation in Brightness Perception

    Directory of Open Access Journals (Sweden)

    Dražen eDomijan

    2015-02-01

    Full Text Available A novel filling-in model is proposed in order to account for challenging brightness illusions where inducing background elements are spatially separated from gray target such as dungeon, cube and grating illusion, bull's eye and ring patterns. The model implements simple idea that neural response to low-contrast contour is enhanced (facilitated by the presence of collinear or parallel high-contrast contour in the wider neighborhood. Contour facilitation is achieved via dendritic inhibition which enables computation of maximum function among inputs to the node. Recurrent application of maximum function leads to the propagation of neural signal along collinear or parallel contour segments. When strong global contour signal is accompanied with weak local contour signal at the same location, conditions are met to produce brightness assimilation within filling-in network. Computer simulations showed that the model correctly predicts brightness appearance in all of the above mentioned illusions as well as in White's effect, Benary's cross, Todorović's illusion, checkerboard contrast, contrast-contrast illusion and various variations on the White's effect. The proposed model offer new insights on how geometric factors (contour colinearity or parallelism jointly with contrast magnitude contribute to the brightness perception.

  10. Radiodiagnosis of gastric diseases on the basis of thin contour findings

    International Nuclear Information System (INIS)

    Zubarev, A.V.; Zavodnov, V.Ya.; Sklyanskaya, O.A.

    1988-01-01

    The authors have analyzed the role of the thin contour in radiodiagnisis of various diseases of the gastric mucosa. Altogether 140 patients with various gastric diseases were investigated. Using X-ray examination of the stomach based on the common 2-phase method, thin contour images were obtained in 80 % of the cases. The results of the investigation have revealed direct correlation between the type of the thin contour and a morphological picture of the gastric mucosa in chronic gastritis. Early stomach cancer was characterized by the local absence or rearrangement of a usual pattern of the thin contour on stomach radiograms. It was difficult to defect single erosions or polyps with a diameter under 5 mm against a background of the gastric mucosa thin contour. Good visualization of stomach areolae, particularly those of a rough nodular type in the proximal part of the stomach was suggestive of an ulcerative lesion

  11. Benefits of cardiac sonography performed by a non-expert sonographer in patients with non-traumatic cardiopulmonary arrest.

    Science.gov (United States)

    Zengin, Suat; Yavuz, Erdal; Al, Behçet; Cindoruk, Şener; Altunbaş, Gökhan; Gümüşboğa, Hasan; Yıldırım, Cuma

    2016-05-01

    The purpose of this study was to evaluate a rapid cardiac ultrasound assessment performed by trained non-expert sonographers integrated into the advanced cardiac life support (ACLS). This study was prospectively performed in 179 patients (104 males and 75 females) who underwent cardiopulmonary resuscitation (CPR) in an emergency department (ED) during two calendar years (2013 and 2014). Two senior doctors, who had received emergency cardiac ultrasonography training, performed cardiac ultrasound through the apical, subxiphoid, or parasternal windows. Ultrasound evaluation and pulse controls were performed simultaneously. SPSS 18.0 was used for statistical analysis. A total of 63.7% (114) of the cardiopulmonary arrest incidents occurred out of the hospital. Only 13 patients had a femoral pulse during the initial evaluation, while 166 showed no femoral pulse. Initial monitoring showed a regular rhythm in 53 patients, ventricular fibrillation in 18 patients, and no rhythms in 108 patients. The first evaluation with ultrasound detected an effective heart rate in 26 patients and ventricular fibrillation in 14 patients, while no effective heart rate was observed in 139 patients. In addition, ultrasound revealed pericardial tamponade in seven patients and right ventricular enlargement in four cases. Global hypokinesia was detected in four patients and hypovolemia was observed in another four patients. The use of real-time ultrasonography during resuscitation with real-time femoral pulse check can help facilitate the distinguishing of pea-type arrest, ascertain the cause of the arrest, infer a suitable treatment, and optimize medical management decisions regarding CPR termination. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Wavelet brain angiography suggests arteriovenous pulse wave phase locking.

    Directory of Open Access Journals (Sweden)

    William E Butler

    Full Text Available When a stroke volume of arterial blood arrives to the brain, the total blood volume in the bony cranium must remain constant as the proportions of arterial and venous blood vary, and by the end of the cardiac cycle an equivalent volume of venous blood must have been ejected. I hypothesize the brain to support this process by an extraluminally mediated exchange of information between its arterial and venous circulations. To test this I introduce wavelet angiography methods to resolve single moving vascular pulse waves (PWs in the brain while simultaneously measuring brain pulse motion. The wavelet methods require angiographic data acquired at significantly faster rate than cardiac frequency. I obtained these data in humans from brain surface optical angiograms at craniotomy and in piglets from ultrasound angiograms via cranial window. I exploit angiographic time of flight to resolve arterial from venous circulation. Initial wavelet reconstruction proved unsatisfactory because of angiographic motion alias from brain pulse motion. Testing with numerically simulated cerebral angiograms enabled the development of a vascular PW cine imaging method based on cross-correlated wavelets of mixed high frequency and high temporal resolution respectively to attenuate frequency and motion alias. Applied to the human and piglet data, the method resolves individual arterial and venous PWs and finds them to be phase locked each with separate phase relations to brain pulse motion. This is consistent with arterial and venous PW coordination mediated by pulse motion and points to a testable hypothesis of a function of cerebrospinal fluid in the ventricles of the brain.

  13. Analysis of contour images using optics of spiral beams

    Science.gov (United States)

    Volostnikov, V. G.; Kishkin, S. A.; Kotova, S. P.

    2018-03-01

    An approach is outlined to the recognition of contour images using computer technology based on coherent optics principles. A mathematical description of the recognition process algorithm and the results of numerical modelling are presented. The developed approach to the recognition of contour images using optics of spiral beams is described and justified.

  14. What Property of the Contour of a Deforming Region Biases Percepts toward Liquid?

    Directory of Open Access Journals (Sweden)

    Takahiro Kawabe

    2017-06-01

    Full Text Available Human observers can perceive the existence of a transparent surface from dynamic image deformation. They can also easily discriminate a transparent solid material such as plastic and glass from a transparent fluid one such as water and shampoo just by viewing them. However, the image information required for material discrimination of this sort is still unclear. A liquid changes its contour shape non-rigidly. We therefore examined whether additional properties of the contour of a deformation-defined region, which indicated contour non-rigidity, biased percepts of the region toward liquid materials. Our stimuli had a translating circular region wherein a natural texture image was deformed at the spatiotemporal deformation frequency that was optimal for the perception of a transparent layer. In Experiment 1, we dynamically deformed the contour of the circular region and found that large deformation of the contour biased the percept toward liquid. In Experiment 2, we manipulated the blurriness of the contour and observed that a strongly blurred contour biased percepts toward liquid. Taken together, the results suggest that a deforming region lacking a discrete contour biases percepts toward liquid.

  15. Contour junctions defined by dynamic image deformations enhance perceptual transparency.

    Science.gov (United States)

    Kawabe, Takahiro; Nishida, Shin'ya

    2017-11-01

    The majority of work on the perception of transparency has focused on static images with luminance-defined contour junctions, but recent work has shown that dynamic image sequences with dynamic image deformations also provide information about transparency. The present study demonstrates that when part of a static image is dynamically deformed, contour junctions at which deforming and nondeforming contours are connected facilitate the deformation-based perception of a transparent layer. We found that the impression of a transparent layer was stronger when a dynamically deforming area was adjacent to static nondeforming areas than when presented alone. When contour junctions were not formed at the dynamic-static boundaries, however, the impression of a transparent layer was not facilitated by the presence of static surrounding areas. The effect of the deformation-defined junctions was attenuated when the spatial pattern of luminance contrast at the junctions was inconsistent with the perceived transparency related to luminance contrast, while the effect did not change when the spatial luminance pattern was consistent with it. In addition, the results showed that contour completions across the junctions were required for the perception of a transparent layer. These results indicate that deformation-defined junctions that involve contour completion between deforming and nondeforming regions enhance the perception of a transparent layer, and that the deformation-based perceptual transparency can be promoted by the simultaneous presence of appropriately configured luminance and contrast-other features that can also by themselves produce the sensation of perceiving transparency.

  16. Gait Recognition Based on Outermost Contour

    Directory of Open Access Journals (Sweden)

    Lili Liu

    2011-10-01

    Full Text Available Gait recognition aims to identify people by the way they walk. In this paper, a simple but e ective gait recognition method based on Outermost Contour is proposed. For each gait image sequence, an adaptive silhouette extraction algorithm is firstly used to segment the frames of the sequence and a series of postprocessing is applied to obtain the normalized silhouette images with less noise. Then a novel feature extraction method based on Outermost Contour is performed. Principal Component Analysis (PCA is adopted to reduce the dimensionality of the distance signals derived from the Outermost Contours of silhouette images. Then Multiple Discriminant Analysis (MDA is used to optimize the separability of gait features belonging to di erent classes. Nearest Neighbor (NN classifier and Nearest Neighbor classifier with respect to class Exemplars (ENN are used to classify the final feature vectors produced by MDA. In order to verify the e ectiveness and robustness of our feature extraction algorithm, we also use two other classifiers: Backpropagation Neural Network (BPNN and Support Vector Machine (SVM for recognition. Experimental results on a gait database of 100 people show that the accuracy of using MDA, BPNN and SVM can achieve 97.67%, 94.33% and 94.67%, respectively.

  17. Neuronal oscillations form parietal/frontal networks during contour integration.

    Science.gov (United States)

    Castellano, Marta; Plöchl, Michael; Vicente, Raul; Pipa, Gordon

    2014-01-01

    The ability to integrate visual features into a global coherent percept that can be further categorized and manipulated are fundamental abilities of the neural system. While the processing of visual information involves activation of early visual cortices, the recruitment of parietal and frontal cortices has been shown to be crucial for perceptual processes. Yet is it not clear how both cortical and long-range oscillatory activity leads to the integration of visual features into a coherent percept. Here, we will investigate perceptual grouping through the analysis of a contour categorization task, where the local elements that form contour must be linked into a coherent structure, which is then further processed and manipulated to perform the categorization task. The contour formation in our visual stimulus is a dynamic process where, for the first time, visual perception of contours is disentangled from the onset of visual stimulation or from motor preparation, cognitive processes that until now have been behaviorally attached to perceptual processes. Our main finding is that, while local and long-range synchronization at several frequencies seem to be an ongoing phenomena, categorization of a contour could only be predicted through local oscillatory activity within parietal/frontal sources, which in turn, would synchronize at gamma (>30 Hz) frequency. Simultaneously, fronto-parietal beta (13-30 Hz) phase locking forms a network spanning across neural sources that are not category specific. Both long range networks, i.e., the gamma network that is category specific, and the beta network that is not category specific, are functionally distinct but spatially overlapping. Altogether, we show that a critical mechanism underlying contour categorization involves oscillatory activity within parietal/frontal cortices, as well as its synchronization across distal cortical sites.

  18. An Event-Related Potential Examination of Contour Integration Deficits in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Pamela D Butler

    2013-03-01

    Full Text Available Perceptual organization, which refers to the ability to integrate fragments of stimuli to form a representation of a whole edge, part, or object, is impaired in schizophrenia. A contour integration paradigm, involving detection of a set of Gabor patches forming an oval contour pointing to the right or left embedded in a field of randomly oriented Gabors, has been developed for use in clinical trials of schizophrenia. The purpose of the present study was to assess contributions of early and later stages of processing to deficits in contour integration, as well as to develop an event-related potential (ERP analog of this task. Twenty-one patients with schizophrenia and 28 controls participated. The Gabor elements forming the contours were given a low or high degree of orientational jitter, making it either easy or difficult to identify the direction in which the contour was pointing. ERP results showed greater negative peaks at ~165 (N1 component and ~270 ms for the low-jitter versus the high-jitter contours, with a much greater difference between jitter conditions at 270 ms. This later ERP component was previously termed Ncl for closure negativity. Source localization identified the Ncl in the lateral occipital object recognition area. Patients showed a significant decrease in the Ncl, but not N1, compared to controls, and this was associated with impaired behavioral ability to identify contours. In addition, an earlier negative peak was found at ~120 ms (termed N120 that differentiated jitter conditions, had a dorsal stream source, and differed between patients and controls. Patients also showed a deficit in the dorsal stream sensory P1 component. These results are in accord with impairments in distributed circuitry contributing to perceptual organization deficits and provide an ERP analog to the behavioral contour integration task.

  19. Lung deflation and oxygen pulse in COPD: results from the NETT randomized trial.

    Science.gov (United States)

    Come, Carolyn E; Divo, Miguel J; San José Estépar, Raúl; Sciurba, Frank C; Criner, Gerard J; Marchetti, Nathaniel; Scharf, Steven M; Mosenifar, Zab; Make, Barry J; Keller, Cesar A; Minai, Omar A; Martinez, Fernando J; Han, MeiLan K; Reilly, John J; Celli, Bartolome R; Washko, George R

    2012-01-01

    In COPD patients, hyperinflation impairs cardiac function. We examined whether lung deflation improves oxygen pulse, a surrogate marker of stroke volume. In 129 NETT patients with cardiopulmonary exercise testing (CPET) and arterial blood gases (ABG substudy), hyperinflation was assessed with residual volume to total lung capacity ratio (RV/TLC), and cardiac function with oxygen pulse (O(2) pulse=VO(2)/HR) at baseline and 6 months. Medical and surgical patients were divided into "deflators" and "non-deflators" based on change in RV/TLC from baseline (∆RV/TLC). We defined deflation as the ∆RV/TLC experienced by 75% of surgical patients. We examined changes in O(2) pulse at peak and similar (iso-work) exercise. Findings were validated in 718 patients who underwent CPET without ABGs. In the ABG substudy, surgical and medical deflators improved their RV/TLC and peak O(2) pulse (median ∆RV/TLC -18.0% vs. -9.3%, p=0.0003; median ∆O(2) pulse 13.6% vs. 1.8%, p=0.12). Surgical deflators also improved iso-work O(2) pulse (0.53 mL/beat, p=0.04 at 20 W). In the validation cohort, surgical deflators experienced a greater improvement in peak O(2) pulse than medical deflators (mean 18.9% vs. 1.1%). In surgical deflators improvements in O(2) pulse at rest and during unloaded pedaling (0.32 mL/beat, pdeflators were 88% more likely than non-deflators to have an improvement in O(2) pulse (OR 1.88, 95% CI 1.30-2.72, p=0.0008). In COPD, decreased hyperinflation through lung volume reduction is associated with improved O(2) pulse. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Time contour expression of limited range phenomena on stack chart; Jugo chart jo deno kyokuchi gensho jikan contour

    Energy Technology Data Exchange (ETDEWEB)

    Kametani, T

    1997-05-27

    Time contour expression of limited range phenomena on stack chart is examined for further improvement on the result of the ultimate interpretation in the seismic reflection survey. The policy is made clear from the beginning that local phenomena are to be discussed, and data prior CMP stacking is interpreted in detail. For this purpose, it is effective to make use of the time contour expression in the midpoint-offset plane simultaneously with the CMP and COP panels. For the review of data prior to CMP stacking, it is convenient to use the CMP (CDP) stacking chart in which the data is arranged methodically. In this chart, all the channels which are crude data prior to stacking are plotted on midpoint-offset coordinates, which plane is called the MOD (Midpoint Offset Domain) panel. Various panels can be chosen unrestrictedly, and their mutual relations can be easily grasped. When data points are given a time axis, they can be expressed in a time contour. Studies are conducted about the underground structure, multiple reflection paths divided by it, and characteristics of detour reflection attributable to faults. 4 refs., 9 figs.

  1. The Effect of Contouring Variability on Dosimetric Parameters for Brain Metastases Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Stanley, Julia; Dunscombe, Peter; Lau, Harold; Burns, Paul; Lim, Gerald; Liu, Hong-Wei; Nordal, Robert; Starreveld, Yves; Valev, Boris; Voroney, Jon-Paul; Spencer, David P.

    2013-01-01

    Purpose: To quantify the effect of contouring variation on stereotactic radiosurgery plan quality metrics for brain metastases. Methods and Materials: Fourteen metastases, each contoured by 8 physicians, formed the basis of this study. A template-based dynamic conformal 5-arc dose distribution was developed for each of the 112 contours, and each dose distribution was applied to the 7 other contours in each patient set. Radiation Therapy Oncology Group (RTOG) plan quality metrics and the Paddick conformity index were calculated for each of the 896 combinations of dose distributions and contours. Results: The ratio of largest to smallest contour volume for each metastasis varied from 1.25 to 4.47, with a median value of 1.68 (n=8). The median absolute difference in RTOG conformity index between the value for the reference contour and the values for the alternative contours was 0.35. The variation of the range of conformity index for all contours for a given tumor varied with the tumor size. Conclusions: The high degree of interobserver contouring variation strongly suggests that peer review or consultation should be adopted to standardize tumor volume prescription. Observer confidence was not reflected in contouring consistency. The impact of contouring variability on plan quality metrics, used as criteria for clinical trial protocol compliance, was such that the category of compliance was robust to interobserver effects only 70% of the time

  2. Towards Stabilizing Parametric Active Contours

    DEFF Research Database (Denmark)

    Liu, Jinchao; Fan, Zhun; Olsen, Søren Ingvor

    2014-01-01

    Numerical instability often occurs in evolving of parametric active contours. This is mainly due to the undesired change of parametrization during evolution. In this paper, we propose a new tangential diffusion term to compensate this undesired change. As a result, the parametrization will converge...

  3. Automatic liver contouring for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Li, Dengwang; Kapp, Daniel S; Xing, Lei; Liu, Li

    2015-01-01

    To develop automatic and efficient liver contouring software for planning 3D-CT and four-dimensional computed tomography (4D-CT) for application in clinical radiation therapy treatment planning systems.The algorithm comprises three steps for overcoming the challenge of similar intensities between the liver region and its surrounding tissues. First, the total variation model with the L1 norm (TV-L1), which has the characteristic of multi-scale decomposition and an edge-preserving property, is used for removing the surrounding muscles and tissues. Second, an improved level set model that contains both global and local energy functions is utilized to extract liver contour information sequentially. In the global energy function, the local correlation coefficient (LCC) is constructed based on the gray level co-occurrence matrix both of the initial liver region and the background region. The LCC can calculate the correlation of a pixel with the foreground and background regions, respectively. The LCC is combined with intensity distribution models to classify pixels during the evolutionary process of the level set based method. The obtained liver contour is used as the candidate liver region for the following step. In the third step, voxel-based texture characterization is employed for refining the liver region and obtaining the final liver contours.The proposed method was validated based on the planning CT images of a group of 25 patients undergoing radiation therapy treatment planning. These included ten lung cancer patients with normal appearing livers and ten patients with hepatocellular carcinoma or liver metastases. The method was also tested on abdominal 4D-CT images of a group of five patients with hepatocellular carcinoma or liver metastases. The false positive volume percentage, the false negative volume percentage, and the dice similarity coefficient between liver contours obtained by a developed algorithm and a current standard delineated by the expert group

  4. Design of a Vibrotactile Vest for Contour Perception

    Directory of Open Access Journals (Sweden)

    Juan Wu

    2012-11-01

    Full Text Available A vibrotactile array is a promising human computer interface which could display graphical information to users in a tactile form. This paper presents the design and testing of an image contour display system with a vibrotactile array. The tactile image display system is attached to the back of the user. It converts visual graphics into 2D tactile images and allows subjects to feel the contours of objects through vibration stimulus. The system consists of a USB camera, 48 (6×8 vibrating motors and an embedded control system. The image is captured by the camera and the 2D contour is extracted and transformed into vibrotactile stimuli using a temporal-spatial dynamic coding method. Preliminary experiments were carried out and the optimal parameters of the vibrating time and duration were explored. To evaluate the feasibility and robustness of this vibration mode, letters were also tactilely displayed and the recognition rate about the alphabet letter display was investigated. It was shown that under the condition of no pre-training for the subjects, the recognition rate was 82%. Such a recognition rate is higher than that of the scanning mode (47.5% and the improved handwriting mode (76.8%. The results indicated that the proposed method was efficient in conveying the contour information to the visually impaired by means of vibrations.

  5. Prenatal exposure to dexamethasone in the mouse alters cardiac growth patterns and increases pulse pressure in aged male offspring.

    Directory of Open Access Journals (Sweden)

    Lee O'Sullivan

    Full Text Available Exposure to synthetic glucocorticoids during development can result in later cardiovascular and renal disease in sheep and rats. Although prenatal glucocorticoid exposure is associated with impaired renal development, less is known about effects on the developing heart. This study aimed to examine the effects of a short-term exposure to dexamethasone (60 hours from embryonic day 12.5 on the developing mouse heart, and cardiovascular function in adult male offspring. Dexamethasone (DEX exposed fetuses were growth restricted compared to saline treated controls (SAL at E14.5, but there was no difference between groups at E17.5. Heart weights of the DEX fetuses also tended to be smaller at E14.5, but not different at E17.5. Cardiac AT1aR, Bax, and IGF-1 mRNA expression was significantly increased by DEX compared to SAL at E17.5. In 12-month-old offspring DEX exposure caused an increase in basal blood pressure of ~3 mmHg. In addition, DEX exposed mice had a widened pulse pressure compared to SAL. DEX exposed males at 12 months had an approximate 25% reduction in nephron number compared to SAL, but no difference in cardiomyocyte number. Exposure to DEX in utero appears to adversely impact on nephrogenesis and heart growth but is not associated with a cardiomyocyte deficit in male mice in adulthood, possibly due to compensatory growth of the myocardium following the initial insult. However, the widened pulse pressure may be indicative of altered vascular compliance.

  6. Female Facial Attractiveness Assessed from Three-Dimensional Contour Lines by University Students

    Directory of Open Access Journals (Sweden)

    Jinwara Jirathamopas

    2018-05-01

    Full Text Available Background: Three-dimensional (3D images could provide more accurate evaluation for facial attractiveness than two-dimensional (2D images. The 3D facial image could be simplified into gray scale 3D contour lines. Whether female facial attractiveness could be perceived in these simplified 3D facial contour lines should be determined. Methods: A series of 100 2D photographs (one frontal and two lateral views and 3D contour lines extracted from 3D facial images of females were projected onto a screen. Each image presentation lasted 5 s, and the evaluators marked their impression of each image’s facial attractiveness on a five-point Likert scale within 3 s of its presentation. The evaluation of the 3D contour lines was performed twice, 2 weeks apart. The evaluators were university students. Results: High consistency (r = 0.92 was found for the first and second evaluation of 3D facial contour lines for female facial attractiveness. The judgments of unattractive face were more consistent than the judgments of attractive face. Male students tended to give lower scores than female students in the evaluation of female facial attractiveness. Conclusions: Female facial attractiveness could be evaluated by 3D facial contour lines. 3D facial contour lines should be one of the key factors of facial attractiveness.

  7. Peripheral Contour Grouping and Saccade Targeting: The Role of Mirror Symmetry

    Directory of Open Access Journals (Sweden)

    Michaël Sassi

    2014-01-01

    Full Text Available Integrating shape contours in the visual periphery is vital to our ability to locate objects and thus make targeted saccadic eye movements to efficiently explore our surroundings. We tested whether global shape symmetry facilitates peripheral contour integration and saccade targeting in three experiments, in which observers responded to a successful peripheral contour detection by making a saccade towards the target shape. The target contours were horizontally (Experiment 1 or vertically (Experiments 2 and 3 mirror symmetric. Observers responded by making a horizontal (Experiments 1 and 2 or vertical (Experiment 3 eye movement. Based on an analysis of the saccadic latency and accuracy, we conclude that the figure-ground cue of global mirror symmetry in the periphery has little effect on contour integration or on the speed and precision with which saccades are targeted towards objects. The role of mirror symmetry may be more apparent under natural viewing conditions with multiple objects competing for attention, where symmetric regions in the visual field can pre-attentively signal the presence of objects, and thus attract eye movements.

  8. Effectiveness of mesotherapy on body contouring.

    Science.gov (United States)

    Park, Seung Ha; Kim, Deok Woo; Lee, Min Ah; Yoo, Sang Chul; Rhee, Seung Chul; Koo, Sang Hwan; Seol, Geun Hye; Cho, Eun Young

    2008-04-01

    Despite the increasing interest in mesotherapy as an alternative method for body contouring, there are few reports of its safety, efficacy, and mechanism of action. A clinical examination was performed to evaluate the efficacy of mesotherapy for body contouring. Twenty women were enrolled in this prospective, case-controlled study over a 12-week period. The authors injected a mixed solution (i.e., aminophylline, buflomedil, and lidocaine) into the superficial dermis of the medial aspect of one thigh weekly using a mechanical delivery gun. There was no treatment to the other thigh. The change in the fat level was evaluated by measuring the girth of the thighs and by computed tomographic scanning. The lipid profiles were checked to determine the effect of mesotherapy on lipid metabolism, and questionnaires were used to determine the satisfaction rate of the patients. The loss of thigh girth on the treated side was not significantly different from that of the untreated side. The computed tomographic scans showed no statistically significant difference in the cross-sectional area or thickness of the fat layer between each group. There were no statistically significant changes in the lipid profiles except for the triglyceride level. A questionnaire asking about the effect of mesotherapy indicated poor patient satisfaction. Mesotherapy is not an effective alternative treatment modality for body contouring.

  9. Automatic Image Segmentation Using Active Contours with Univariate Marginal Distribution

    Directory of Open Access Journals (Sweden)

    I. Cruz-Aceves

    2013-01-01

    Full Text Available This paper presents a novel automatic image segmentation method based on the theory of active contour models and estimation of distribution algorithms. The proposed method uses the univariate marginal distribution model to infer statistical dependencies between the control points on different active contours. These contours have been generated through an alignment process of reference shape priors, in order to increase the exploration and exploitation capabilities regarding different interactive segmentation techniques. This proposed method is applied in the segmentation of the hollow core in microscopic images of photonic crystal fibers and it is also used to segment the human heart and ventricular areas from datasets of computed tomography and magnetic resonance images, respectively. Moreover, to evaluate the performance of the medical image segmentations compared to regions outlined by experts, a set of similarity measures has been adopted. The experimental results suggest that the proposed image segmentation method outperforms the traditional active contour model and the interactive Tseng method in terms of segmentation accuracy and stability.

  10. Differential contribution of early visual areas to the perceptual process of contour processing.

    Science.gov (United States)

    Schira, Mark M; Fahle, Manfred; Donner, Tobias H; Kraft, Antje; Brandt, Stephan A

    2004-04-01

    We investigated contour processing and figure-ground detection within human retinotopic areas using event-related functional magnetic resonance imaging (fMRI) in 6 healthy and naïve subjects. A figure (6 degrees side length) was created by a 2nd-order texture contour. An independent and demanding foveal letter-discrimination task prevented subjects from noticing this more peripheral contour stimulus. The contour subdivided our stimulus into a figure and a ground. Using localizers and retinotopic mapping stimuli we were able to subdivide each early visual area into 3 eccentricity regions corresponding to 1) the central figure, 2) the area along the contour, and 3) the background. In these subregions we investigated the hemodynamic responses to our stimuli and compared responses with or without the contour defining the figure. No contour-related blood oxygenation level-dependent modulation in early visual areas V1, V3, VP, and MT+ was found. Significant signal modulation in the contour subregions of V2v, V2d, V3a, and LO occurred. This activation pattern was different from comparable studies, which might be attributable to the letter-discrimination task reducing confounding attentional modulation. In V3a, but not in any other retinotopic area, signal modulation corresponding to the central figure could be detected. Such contextual modulation will be discussed in light of the recurrent processing hypothesis and the role of visual awareness.

  11. Impact of region contouring variability on image-based focal therapy evaluation

    Science.gov (United States)

    Gibson, Eli; Donaldson, Ian A.; Shah, Taimur T.; Hu, Yipeng; Ahmed, Hashim U.; Barratt, Dean C.

    2016-03-01

    Motivation: Focal therapy is an emerging low-morbidity treatment option for low-intermediate risk prostate cancer; however, challenges remain in accurately delivering treatment to specified targets and determining treatment success. Registered multi-parametric magnetic resonance imaging (MPMRI) acquired before and after treatment can support focal therapy evaluation and optimization; however, contouring variability, when defining the prostate, the clinical target volume (CTV) and the ablation region in images, reduces the precision of quantitative image-based focal therapy evaluation metrics. To inform the interpretation and clarify the limitations of such metrics, we investigated inter-observer contouring variability and its impact on four metrics. Methods: Pre-therapy and 2-week-post-therapy standard-of-care MPMRI were acquired from 5 focal cryotherapy patients. Two clinicians independently contoured, on each slice, the prostate (pre- and post-treatment) and the dominant index lesion CTV (pre-treatment) in the T2-weighted MRI, and the ablated region (post-treatment) in the dynamic-contrast- enhanced MRI. For each combination of clinician contours, post-treatment images were registered to pre-treatment images using a 3D biomechanical-model-based registration of prostate surfaces, and four metrics were computed: the proportion of the target tissue region that was ablated and the target:ablated region volume ratio for each of two targets (the CTV and an expanded planning target volume). Variance components analysis was used to measure the contribution of each type of contour to the variance in the therapy evaluation metrics. Conclusions: 14-23% of evaluation metric variance was attributable to contouring variability (including 6-12% from ablation region contouring); reducing this variability could improve the precision of focal therapy evaluation metrics.

  12. Significance of spin-echo intracardiac signal during cine cardiac MR imaging

    International Nuclear Information System (INIS)

    Feiglin, D.H.I.; O'Donnell, J.K.

    1987-01-01

    Thirty patient studies were performed using several multisection spin multi-echo pulse sequences (SEPS) formattable into the cine mode, with repetition time (TR)≤RR interval and 18 msec ≤ echo time (TE) ≤ 64 msec. Thirteen studies were performed in patients with various cardiomyopathies, ten in patients with cardiac tumors, and seven in healthy volunteers. The SEPS in the multi-echo acquisition format differentiated between tumor and stasis in terms of signal behavior. Healthy subjects may exhibit stasis of flow adjacent to the endocardium during the cardiac cycle

  13. Ocular pulse amplitude after panretinal photocoagulation in normotensive eyes with proliferative diabetic retinopathy.

    Science.gov (United States)

    Bozic, Marija M; Karadzic, Jelena B; Kovacevic, Igor M; Marjanovic, Ivan S

    2017-06-26

    To assess the effect of panretinal laser photocoagulation on ocular pulse amplitude (OPA) in normotensive eyes with proliferative diabetic retinopathy. Prospectively, we performed unilateral argon laser panretinal photocoagulation (PRP) in 30 patients with diabetes mellitus type II and previously untreated bilateral proliferative diabetic retinopathy. Before and 7 and 30 days after the treatment, OPA was measured using dynamic contour tonometer. Compared with the untreated contralateral eyes, laser photocoagulation led to a reduction of OPA. Ocular pulse amplitude did not significantly differ in photocoagulated eyes 7 days after the treatment, but there was a significant difference in OPA 30 days after the treatment. The decrease in OPA values was 15% 7 days after PRP and 40% 30 days after PRP. Ocular pulse amplitude reduction after PRP indirectly informs us about choriocapillary closure, already reported in previous studies.

  14. Adaptive Pseudo Dilation for Gestalt Edge Grouping and Contour Detection

    NARCIS (Netherlands)

    Papari, Giuseppe; Petkov, Nicolai

    2008-01-01

    We consider the problem of detecting object contours in natural images. In many cases, local luminance changes turn out to be stronger in textured areas than on object contours. Therefore, local edge features, which only look at a small neighborhood of each pixel, cannot be reliable indicators of

  15. Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering

    International Nuclear Information System (INIS)

    Yamamura, Jin; Frisch, Michael; Ecker, Hannes; Adam, Gerhard; Wedegaertner, Ulrike; Graessner, Joachim; Hecher, Kurt

    2011-01-01

    To investigate the self-gating technique for MR imaging of the fetal heart in a sheep model. MR images of 6 fetal sheep heart were obtained at 1.5T. For self-gating MRI of the fetal heart a cine SSFP in short axis, two and four chamber view was used. Self-gated images were compared with real cardiac triggered MR images (pulse-wave triggering). MRI of the fetal heart was performed using both techniques simultaneously. Image quality was assessed and the left ventricular volume and function were measured and compared. Compared with pulse-wave triggering, the self-gating technique produced slightly inferior images with artifacts. Especially the atrial septum could not be so clearly depicted. The contraction of the fetal heart was shown in cine sequences in both techniques. The average blood volumes could be measured with both techniques with no significant difference: at end-systole 3.1 ml (SD± 0.2), at end-diastole 4.9 ml (±0.2), with ejection fractions at 38.6%, respectively 39%. Both self-gating and pulse-wave triggered cardiac MRI of the fetal heart allowed the evaluation of anatomical structures and functional information. Images obtained by self-gating technique were slightly inferior than the pulse-wave triggered MRI. (orig.)

  16. Measurement of laser welding pool geometry using a closed convex active contour model

    International Nuclear Information System (INIS)

    Zheng, Rui; Zhang, Pu; Duan, Aiqing; Xiao, Peng

    2014-01-01

    The purpose of this study was to develop a computer vision method to measure geometric parameters of the weld pool in a deep penetration CO 2 laser welding system. Accurate measurement was achieved by removing a huge amount of interference caused by spatter, arc light and plasma to extract the true weld pool contour. This paper introduces a closed convex active contour (CCAC) model derived from the active contour model (snake model), which is a more robust high-level vision method than the traditional low-level vision methods. We made an improvement by integrating an active contour with the information that the weld pool contour is almost a closed convex curve. An effective thresholding method and an improved greedy algorithm are also given to complement the CCAC model. These influences can be effectively removed by using the CCAC model to acquire and measure the weld pool contour accurately and relatively fast. (paper)

  17. Effect of experimental hyperthyroidism on protein turnover in skeletal and cardiac muscle.

    Science.gov (United States)

    Carter, W J; Van Der Weijden Benjamin, W S; Faas, F H

    1980-10-01

    Since experimental hyperthyroidism reduces skeletal muscle mass while simultaneously increasing cardiac muscle mass, the effect of hyperthyroidism on muscle protein degradation was compared in skeletal and cardiac muscle. Pulse-labeling studies using (3H) leucine and (14C) carboxyl labeled aspartate and glutamate were carried out. Hyperthyroidism caused a 25%-29% increase in protein breakdown in both sarcoplasmic and myofibrillar fractions of skeletal muscle. Increased muscle protein degradation may be a major factor in the development of skeletal muscle wasting and weakness in hyperthyroidism. In contrast, protein breakdown appeared to be reduced 22% in the sarcoplasmic fraction of hyperthyroid heart muscle and was unchanged in the myofibrillar fraction. Possible reasons for the contrasting effects of hyperthyroidism on skeletal and cardiac muscle include increased sensitivity of the hyperthyroid heart to catecholamines, increased cardiac work caused by the hemodynamic effects of hyperthyroidism, and a different direct effect of thyroid hormone at the nuclear level in cardiac as opposed to skeletal muscle.

  18. Imaging the heart: cardiac scintigraphy and echocardiography in US hospitals (1983)

    International Nuclear Information System (INIS)

    McPhee, S.J.; Garnick, D.W.

    1986-01-01

    The rapid growth of cardiac catheterization has raised questions about the availability of less costly, noninvasive tests such as cardiac scintigraphy and echocardiography. To assess their availability and rates of use, we surveyed 3778 non-federal short-term US hospitals in June, 1983. Overall, 2605 hospitals (69%) offered 201 Tl myocardial perfusion scans, 2580 (68%) 99mTc equilibrium gated blood pool scans, and 2483 (67%) cardiac shunt scans; 1679 hospitals (44%) offered M-mode and/or 2-dimensional echocardiography, and 768 (20%) pulsed Doppler echocardiography. Volumes of procedures varied enormously among hospitals capable of performing them. High volumes of both scintigraphy and echocardiography were performed in a small number of hospitals. Larger, voluntary, and teaching hospitals performed higher volumes of both procedures. Despite widespread availability of these noninvasive technologies, high volumes of both cardiac scintigraphy and echocardiography procedures are concentrated in a small number of US hospitals

  19. Assessment and improvement of radiation oncology trainee contouring ability utilizing consensus-based penalty metrics

    International Nuclear Information System (INIS)

    Hallock, Abhirami; Read, Nancy; D'Souza, David

    2012-01-01

    The objective of this study was to develop and assess the feasibility of utilizing consensus-based penalty metrics for the purpose of critical structure and organ at risk (OAR) contouring quality assurance and improvement. A Delphi study was conducted to obtain consensus on contouring penalty metrics to assess trainee-generated OAR contours. Voxel-based penalty metric equations were used to score regions of discordance between trainee and expert contour sets. The utility of these penalty metric scores for objective feedback on contouring quality was assessed by using cases prepared for weekly radiation oncology radiation oncology trainee treatment planning rounds. In two Delphi rounds, six radiation oncology specialists reached agreement on clinical importance/impact and organ radiosensitivity as the two primary criteria for the creation of the Critical Structure Inter-comparison of Segmentation (CriSIS) penalty functions. Linear/quadratic penalty scoring functions (for over- and under-contouring) with one of four levels of severity (none, low, moderate and high) were assigned for each of 20 OARs in order to generate a CriSIS score when new OAR contours are compared with reference/expert standards. Six cases (central nervous system, head and neck, gastrointestinal, genitourinary, gynaecological and thoracic) then were used to validate 18 OAR metrics through comparison of trainee and expert contour sets using the consensus derived CriSIS functions. For 14 OARs, there was an improvement in CriSIS score post-educational intervention. The use of consensus-based contouring penalty metrics to provide quantitative information for contouring improvement is feasible.

  20. VT Data - Lidar 1ft Contours

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This metadata applies to contours derived from Quality Level 2 (QL2) Lidar 'collections' with a resolution (RESCLASS) of 0.7m. For an overview of...

  1. 47 CFR 73.6010 - Class A TV station protected contour.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Class A TV station protected contour. 73.6010... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6010 Class A TV station protected contour. (a) A Class A TV station will be protected from interference within the following predicted...

  2. What is in a contour map? A region-based logical formalization of contour semantics

    Science.gov (United States)

    Usery, E. Lynn; Hahmann, Torsten

    2015-01-01

    Contours maps (such as topographic maps) compress the information of a function over a two-dimensional area into a discrete set of closed lines that connect points of equal value (isolines), striking a fine balance between expressiveness and cognitive simplicity. They allow humans to perform many common sense reasoning tasks about the underlying function (e.g. elevation).

  3. From Inpainting to Active Contours

    DEFF Research Database (Denmark)

    Lauze, Francois Bernard; Nielsen, Mads

    2008-01-01

    state equation). The contour evolution is implemented in the framework of level sets. Finally, the proposed method is validated on various examples. We focus among others in the segmentation of calcified plaques observed in radiographs from human lumbar aortic regions. Keywords  Segmentation - Inpainting - Active...

  4. Evaluation of blood signal in cardiac MR imaging using ''black-blood'' technique

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Yamada, Takayuki; Tamura, Akihisa; Miyasaka, Kenji; Kohata, Minako; Ono, Chiaki; Kajima, Toshio; Ito, Katsuhide

    1999-01-01

    Degradation of image quality encountered in cardiac imaging has been attributed to flowing blood signal in the ventricular cavity. To solve this problem, a sequence in which a pair of selective and non-selective inversion pulse in used for a preparation pulse, has been proposed. However, even with this sequence we frequently observed the signal in the blood pool caused by blood itself rather than blood flow. In this article, we investigated the characteristics of those signals. Five healthy normal volunteers and 13 patients with ischemic heart disease were scanned with a 1.5-tesla MR imager. Breath-hold ECG gated fast spin echo with the pair of inversion pulses was performed to obtain cardiac images with T 2 contrast. Typical blood signal appeared as inhomogeneous high intense band adjacent to inner surface of left ventricular apex. At ventricular base, no such signal was encountered even at akinetic myocardium in patients with old myocardial infarction. This signal was observed in all volunteers and 39% of patients. Decrease of TR resulting from tachycardia tended to reduce the blood signal in the left ventricular cavity. Thicker slice section and selective inversion pulse tended to increase the blood signal. Recognition of the signal is essential to differentiate true myocardial infarcts from blood signal, although bright blood imaging like gradient echo or thinner section can partly be helpful. (author)

  5. Dynamic contour tonometry: presentation of a new tonometer.

    Science.gov (United States)

    Kanngiesser, Hartmut E; Kniestedt, Christoph; Robert, Yves C A

    2005-10-01

    With tonometers currently in use intraocular pressure is indirectly determined by measuring a physical quantity related to a specified deformation of the cornea. We present a new principle of direct, continuous, and transcorneal intraocular pressure measurement, describe its theoretical foundation, and evaluate its application on the basis of an in vitro model. On a living human eye an optimized pressure-sensitive contact surface was determined by performing pressure measurements with differently shaped tonometer heads. Based on these results and on the theoretical model, a Dynamic Contour Tonometer was constructed and validated on eye bank bulbi against a manometric reference pressure. A concave contact surface with a radius of curvature of 10.5 mm creates a distribution of forces between the central contour matching area of the tip and the cornea that equals the forces generated by the internal pressure of the eye. A sensor integrated into the surface having the same contour measures the intraocular pressure closely to the manometric reference pressure in human cadaver eyes. The accuracy of the tonometer appears to be unaffected by variations in corneal properties. Dynamic Contour Tonometry eliminates most of the systematic errors arising from individual changes of corneal properties that adversely influence all types of applanation tonometers. The advantage of measuring the true pressure in combination with the capability of registering dynamic pressure fluctuations discloses new tonometric opportunities to diagnose and classify different types of glaucoma.

  6. Contour entropy: a new determinant of perceiving ground or a hole.

    Science.gov (United States)

    Gillam, Barbara J; Grove, Philip M

    2011-06-01

    Figure-ground perception is typically described as seeing one surface occluding another. Figure properties, not ground properties, are considered the significant factors. In scenes, however, a near surface will often occlude multiple contours and surfaces, often at different depths, producing alignments that are improbable except under conditions of occlusion. We thus hypothesized that unrelated (high entropy) lines would tend to appear as ground in a figure-ground paradigm more often than similarly aligned ordered (low entropy) lines. We further hypothesized that for lines spanning a closed area, high line entropy should increase the hole-like appearance of that area. These predictions were confirmed in three experiments. The probability that patterned rectangles were seen as ground when alternated with blank rectangles increased with pattern entropy. A single rectangular shape appeared more hole-like when the entropy of the enclosed contours increased. Furthermore, these same contours, with the outline shape removed, gave rise to bounding illusory contours whose strength increased with contour entropy. We conclude that figure-ground and hole perception can be determined by properties of ground in the absence of any figural shape, or surround, factors.

  7. Correlations between contouring similarity metrics and simulated treatment outcome for prostate radiotherapy

    Science.gov (United States)

    Roach, D.; Jameson, M. G.; Dowling, J. A.; Ebert, M. A.; Greer, P. B.; Kennedy, A. M.; Watt, S.; Holloway, L. C.

    2018-02-01

    Many similarity metrics exist for inter-observer contouring variation studies, however no correlation between metric choice and prostate cancer radiotherapy dosimetry has been explored. These correlations were investigated in this study. Two separate trials were undertaken, the first a thirty-five patient cohort with three observers, the second a five patient dataset with ten observers. Clinical and planning target volumes (CTV and PTV), rectum, and bladder were independently contoured by all observers in each trial. Structures were contoured on T2-weighted MRI and transferred onto CT following rigid registration for treatment planning in the first trial. Structures were contoured directly on CT in the second trial. STAPLE and majority voting volumes were generated as reference gold standard volumes for each structure for the two trials respectively. VMAT treatment plans (78 Gy to PTV) were simulated for observer and gold standard volumes, and dosimetry assessed using multiple radiobiological metrics. Correlations between contouring similarity metrics and dosimetry were calculated using Spearman’s rank correlation coefficient. No correlations were observed between contouring similarity metrics and dosimetry for CTV within either trial. Volume similarity correlated most strongly with radiobiological metrics for PTV in both trials, including TCPPoisson (ρ  =  0.57, 0.65), TCPLogit (ρ  =  0.39, 0.62), and EUD (ρ  =  0.43, 0.61) for each respective trial. Rectum and bladder metric correlations displayed no consistency for the two trials. PTV volume similarity was found to significantly correlate with rectum normal tissue complication probability (ρ  =  0.33, 0.48). Minimal to no correlations with dosimetry were observed for overlap or boundary contouring metrics. Future inter-observer contouring variation studies for prostate cancer should incorporate volume similarity to provide additional insights into dosimetry during analysis.

  8. Contouring a guide to the analysis and display of spatial data

    CERN Document Server

    Watson, Debbie

    2013-01-01

    This unique book is the key to computer contouring, exploring in detail the practice and principles using a personal computer. Contouring allows a three dimensional view in two dimensions and is a fundamental technique to represent spatial data. All aspects of this type of representation are covered including data preparation, selecting contour intervals, interpolation and griding, computing volumes and output and display. Formulated for both the novice and the experienced user, this book initially conducts the reader through a step by step explanation of PC software and its application to per

  9. An approach to contouring the dorsal vagal complex for radiotherapy planning

    Energy Technology Data Exchange (ETDEWEB)

    O' Steen, Lillie; Amdur, Robert J., E-mail: amdurr@shands.ufl.edu

    2016-04-01

    Multiple studies suggest that radiation dose to the area of the brainstem called the “dorsal vagal complex (DVC)” influences the frequency of nausea and vomiting during radiotherapy. The purpose of this didactic article is to describe the step-by-step process that we use to contour the general area of the DVC on axial computed tomography (CT) images as would be done for radiotherapy planning. The contouring procedure that we describe for contouring the area of the DVC is useful to medical dosimetrists and radiation oncologists.

  10. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu [Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Reamer, Courtney B.; Mohler, Emile R. [Department of Medicine, Division of Cardiovascular Medicine, Section of Vascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2014-02-15

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  11. Standardization of surgical techniques used in facial bone contouring.

    Science.gov (United States)

    Lee, Tae Sung

    2015-12-01

    Since the introduction of facial bone contouring surgery for cosmetic purposes, various surgical methods have been used to improve the aesthetics of facial contours. In general, by standardizing the surgical techniques, it is possible to decrease complication rates and achieve more predictable surgical outcomes, thereby increasing patient satisfaction. The technical strategies used by the author to standardize facial bone contouring procedures are introduced here. The author uses various pre-manufactured surgical tools and hardware for facial bone contouring. During a reduction malarplasty or genioplasty procedure, double-bladed reciprocating saws and pre-bent titanium plates customized for the zygomatic body, arch and chin are used. Various guarded oscillating saws are used for mandibular angloplasty. The use of double-bladed saws and pre-bent plates to perform reduction malarplasty reduces the chances of post-operative asymmetry or under- or overcorrection of the zygoma contours due to technical faults. Inferior alveolar nerve injury and post-operative jawline asymmetry or irregularity can be reduced by using a guarded saw during mandibular angloplasty. For genioplasty, final placement of the chin in accordance with preoperative quantitative analysis can be easily performed with pre-bent plates, and a double-bladed saw allows more procedural accuracy during osteotomies. Efforts by the surgeon to avoid unintentional faults are key to achieving satisfactory results and reducing the incidence of complications. The surgical techniques described in this study in conjunction with various in-house surgical tools and modified hardware can be used to standardize techniques to achieve aesthetically gratifying outcomes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Surface filling-in and contour interpolation contribute independently to Kanizsa figure formation.

    Science.gov (United States)

    Chen, Siyi; Glasauer, Stefan; Müller, Hermann J; Conci, Markus

    2018-04-30

    To explore mechanisms of object integration, the present experiments examined how completion of illusory contours and surfaces modulates the sensitivity of localizing a target probe. Observers had to judge whether a briefly presented dot probe was located inside or outside the region demarcated by inducer elements that grouped to form variants of an illusory, Kanizsa-type figure. From the resulting psychometric functions, we determined observers' discrimination thresholds as a sensitivity measure. Experiment 1 showed that sensitivity was systematically modulated by the amount of surface and contour completion afforded by a given configuration. Experiments 2 and 3 presented stimulus variants that induced an (occluded) object without clearly defined bounding contours, which gave rise to a relative sensitivity increase for surface variations on their own. Experiments 4 and 5 were performed to rule out that these performance modulations were simply attributable to variable distances between critical local inducers or to costs in processing an interrupted contour. Collectively, the findings provide evidence for a dissociation between surface and contour processing, supporting a model of object integration in which completion is instantiated by feedforward processing that independently renders surface filling-in and contour interpolation and a feedback loop that integrates these outputs into a complete whole. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  13. Purse-string platysmaplasty: the third dimension for neck contouring.

    Science.gov (United States)

    Gentile, Richard D

    2005-11-01

    Techniques and concepts for treatment of the aging neck have been evolving since the late 1960s and rely on two-dimensional anterior approximation with lateral imbrication of the platysma with or without submental fat reduction, However, the medial approximation can sometimes give a "boxy" appearance to the anterior neck, especially if anterior shifting of the platysma recurs after platysmaplasty with laxity redeveloping in this midline location. The "purse-string" platysmaplasty (PSP) is a new concept in neck contouring that facilitates an enhanced definition for the cervicomandibular transition to better simulate the well-defined contour of this transition that is present in youth. It aids in the contouring of difficult poorly defined necks and in male patients. The PSP adds a "third dimension" to neck recontouring by invaginating the platysma with a plication suture and pexing the platysma, without incising it, to deeper neck fascia with a technique that adds support and definition to the neck contour. The PSP can be performed in patients undergoing a full rhytidectomy as well as in individuals having isolated neck rejuvenation. The PSP is especially helpful in rejuvenating the male lower face and neck because of the relatively heavier deeper structures of the male neck and the need to enhance definition along the jawline.

  14. Acute effect of Vagus nerve stimulation parameters on cardiac chronotropic, inotropic, and dromotropic responses

    Science.gov (United States)

    Ojeda, David; Le Rolle, Virginie; Romero-Ugalde, Hector M.; Gallet, Clément; Bonnet, Jean-Luc; Henry, Christine; Bel, Alain; Mabo, Philippe; Carrault, Guy; Hernández, Alfredo I.

    2017-11-01

    Vagus nerve stimulation (VNS) is an established therapy for drug-resistant epilepsy and depression, and is considered as a potential therapy for other pathologies, including Heart Failure (HF) or inflammatory diseases. In the case of HF, several experimental studies on animals have shown an improvement in the cardiac function and a reverse remodeling of the cardiac cavity when VNS is applied. However, recent clinical trials have not been able to reproduce the same response in humans. One of the hypothesis to explain this lack of response is related to the way in which stimulation parameters are defined. The combined effect of VNS parameters is still poorly-known, especially in the case of VNS synchronously delivered with cardiac activity. In this paper, we propose a methodology to analyze the acute cardiovascular effects of VNS parameters individually, as well as their interactive effects. A Latin hypercube sampling method was applied to design a uniform experimental plan. Data gathered from this experimental plan was used to produce a Gaussian process regression (GPR) model in order to estimate unobserved VNS sequences. Finally, a Morris screening sensitivity analysis method was applied to each obtained GPR model. Results highlight dominant effects of pulse current, pulse width and number of pulses over frequency and delay and, more importantly, the degree of interactions between these parameters on the most important acute cardiovascular responses. In particular, high interacting effects between current and pulse width were found. Similar sensitivity profiles were observed for chronotropic, dromotropic and inotropic effects. These findings are of primary importance for the future development of closed-loop, personalized neuromodulator technologies.

  15. Pattern of perioperative cardiac arrests at University of Maiduguri Teaching Hospital.

    Science.gov (United States)

    Kwari, Y D; Bello, M R; Eni, U E

    2010-01-01

    Perioperative cardiac arrests and death on the table represent the most serious complications of surgery and anaesthesia. This paper was designed to study their pattern, causes and outcomes following cardiopulmonary resuscitation (CPR) and intensive care unit (ICU) management in our institution. Three year retrospective review of perioperative cardiac arrests and death on operating table following surgical procedure under anaesthesia. For each cardiac arrest or death on the table the sequence of events leading to the arrest was evaluated using case notes, anaesthetic chart and ICU records. Study variables which include demographic data, ASA score, anaesthetic technique, causes and outcome were analysed and discussed. Fourteen perioperative cardiac arrests were encountered following 4051 anaesthetics administered over the three year study period. Twelve out of the fourteen cardiac arrests occurred following general anaesthesia, while the remaining two occurred following spinal anaesthesia. There was no cardiac arrest following local anaesthesia. Children suffered more cardiac arrest than adults. ASA class III and IV risk status suffered more arrests than ASA I and II. Hypoxia from airway problems was the commonest cause of cardiac arrest followed by septic shock. Monitoring with pulse oximeter was done in only 4 out of the 14 cardiac arrests. Only 2 (14%) out of 14 cardiac arrests recovered to home discharge, one of them with significant neurological deficit. Majority of arrests were due to hypoxia from airway problems that were not detected early There is need to improve on patient monitoring, knowledge of CPR and intensive care so as to improve the outcome of perioperative cardiac arrest.

  16. Contour Detection for UAV-Based Cadastral Mapping

    Directory of Open Access Journals (Sweden)

    Sophie Crommelinck

    2017-02-01

    Full Text Available Unmanned aerial vehicles (UAVs provide a flexible and low-cost solution for the acquisition of high-resolution data. The potential of high-resolution UAV imagery to create and update cadastral maps is being increasingly investigated. Existing procedures generally involve substantial fieldwork and many manual processes. Arguably, multiple parts of UAV-based cadastral mapping workflows could be automated. Specifically, as many cadastral boundaries coincide with visible boundaries, they could be extracted automatically using image analysis methods. This study investigates the transferability of gPb contour detection, a state-of-the-art computer vision method, to remotely sensed UAV images and UAV-based cadastral mapping. Results show that the approach is transferable to UAV data and automated cadastral mapping: object contours are comprehensively detected at completeness and correctness rates of up to 80%. The detection quality is optimal when the entire scene is covered with one orthoimage, due to the global optimization of gPb contour detection. However, a balance between high completeness and correctness is hard to achieve, so a combination with area-based segmentation and further object knowledge is proposed. The localization quality exhibits the usual dependency on ground resolution. The approach has the potential to accelerate the process of general boundary delineation during the creation and updating of cadastral maps.

  17. On a program manifold's stability of one contour automatic control systems

    Science.gov (United States)

    Zumatov, S. S.

    2017-12-01

    Methodology of analysis of stability is expounded to the one contour systems automatic control feedback in the presence of non-linearities. The methodology is based on the use of the simplest mathematical models of the nonlinear controllable systems. Stability of program manifolds of one contour automatic control systems is investigated. The sufficient conditions of program manifold's absolute stability of one contour automatic control systems are obtained. The Hurwitz's angle of absolute stability was determined. The sufficient conditions of program manifold's absolute stability of control systems by the course of plane in the mode of autopilot are obtained by means Lyapunov's second method.

  18. Pulse methylprednisolone therapy for impending cardiac tamponade in immunoglobulin-resistant Kawasaki disease

    NARCIS (Netherlands)

    Dahlem, P. G.; von Rosenstiel, I. A.; Lam, J.; Kuijpers, T. W.

    1999-01-01

    We describe a boy with Kawasaki disease (KD) whose clinical course was marked by a rapid improvement upon treatment with intravenous immunoglobulin (IVIG) and oral aspirin, which - within 14 days - was followed by the development of a large pericardial effusion with symptoms of impending cardiac

  19. Joint classification and contour extraction of large 3D point clouds

    Science.gov (United States)

    Hackel, Timo; Wegner, Jan D.; Schindler, Konrad

    2017-08-01

    We present an effective and efficient method for point-wise semantic classification and extraction of object contours of large-scale 3D point clouds. What makes point cloud interpretation challenging is the sheer size of several millions of points per scan and the non-grid, sparse, and uneven distribution of points. Standard image processing tools like texture filters, for example, cannot handle such data efficiently, which calls for dedicated point cloud labeling methods. It turns out that one of the major drivers for efficient computation and handling of strong variations in point density, is a careful formulation of per-point neighborhoods at multiple scales. This allows, both, to define an expressive feature set and to extract topologically meaningful object contours. Semantic classification and contour extraction are interlaced problems. Point-wise semantic classification enables extracting a meaningful candidate set of contour points while contours help generating a rich feature representation that benefits point-wise classification. These methods are tailored to have fast run time and small memory footprint for processing large-scale, unstructured, and inhomogeneous point clouds, while still achieving high classification accuracy. We evaluate our methods on the semantic3d.net benchmark for terrestrial laser scans with >109 points.

  20. Collinear facilitation and contour integration in autism: evidence for atypical visual integration.

    Science.gov (United States)

    Jachim, Stephen; Warren, Paul A; McLoughlin, Niall; Gowen, Emma

    2015-01-01

    Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by impaired social interaction, atypical communication and a restricted repertoire of interests and activities. Altered sensory and perceptual experiences are also common, and a notable perceptual difference between individuals with ASD and controls is their superior performance in visual tasks where it may be beneficial to ignore global context. This superiority may be the result of atypical integrative processing. To explore this claim we investigated visual integration in adults with ASD (diagnosed with Asperger's Syndrome) using two psychophysical tasks thought to rely on integrative processing-collinear facilitation and contour integration. We measured collinear facilitation at different flanker orientation offsets and contour integration for both open and closed contours. Our results indicate that compared to matched controls, ASD participants show (i) reduced collinear facilitation, despite equivalent performance without flankers; and (ii) less benefit from closed contours in contour integration. These results indicate weaker visuospatial integration in adults with ASD and suggest that further studies using these types of paradigms would provide knowledge on how contextual processing is altered in ASD.

  1. Collinear facilitation and contour integration in autism: evidence for atypical visual integration

    Directory of Open Access Journals (Sweden)

    Stephen eJachim

    2015-03-01

    Full Text Available Autism spectrum disorder (ASD is a neurodevelopmental disorder characterized by impaired social interaction, atypical communication and a restricted repertoire of interests and activities. Altered sensory and perceptual experiences are also common, and a notable perceptual difference between individuals with ASD and controls is their superior performance in visual tasks where it may be beneficial to ignore global context. This superiority may be the result of atypical integrative processing. To explore this claim we investigated visual integration in adults with ASD (diagnosed with Asperger’s Syndrome using two psychophysical tasks thought to rely on integrative processing - collinear facilitation and contour integration. We measured collinear facilitation at different flanker orientation offsets and contour integration for both open and closed contours. Our results indicate that compared to matched controls, ASD participants show (i reduced collinear facilitation, despite equivalent performance without flankers and (ii less benefit from closed contours in contour integration. These results indicate weaker visuospatial integration in adults with ASD and suggest that further studies using these types of paradigms would provide knowledge on how contextual processing is altered in ASD.

  2. A historical note on illusory contours in shadow writing.

    Science.gov (United States)

    Vezzani, Stefano; Marino, Barbara F M

    2009-01-01

    It is widely accepted that illusory contours have been first displayed and discussed by Schumann (1900, Zeitschrift für Psychologie und Physiologie der Sinnesorgane 23 1-32). Here we show that, before him, Jastrow (1899, Popular Science Monthly 54 299-312) produced illusory contours consisting of a shadow word. A brief history of shadow writing in psychological literature from Jastrow to Brunswik is presented, in which the contributions of Pillsbury, Warren, Koffka, and Benussi are examined.

  3. NSCT BASED LOCAL ENHANCEMENT FOR ACTIVE CONTOUR BASED IMAGE SEGMENTATION APPLICATION

    Directory of Open Access Journals (Sweden)

    Hiren Mewada

    2010-08-01

    Full Text Available Because of cross-disciplinary nature, Active Contour modeling techniques have been utilized extensively for the image segmentation. In traditional active contour based segmentation techniques based on level set methods, the energy functions are defined based on the intensity gradient. This makes them highly sensitive to the situation where the underlying image content is characterized by image nonhomogeneities due to illumination and contrast condition. This is the most difficult problem to make them as fully automatic image segmentation techniques. This paper introduces one of the approaches based on image enhancement to this problem. The enhanced image is obtained using NonSubsampled Contourlet Transform, which improves the edges strengths in the direction where the illumination is not proper and then active contour model based on level set technique is utilized to segment the object. Experiment results demonstrate that proposed method can be utilized along with existing active contour model based segmentation method under situation characterized by intensity non-homogeneity to make them fully automatic.

  4. A framework for automated contour quality assurance in radiation therapy including adaptive techniques

    International Nuclear Information System (INIS)

    Altman, M B; Kavanaugh, J A; Wooten, H O; Green, O L; DeWees, T A; Gay, H; Thorstad, W L; Li, H; Mutic, S

    2015-01-01

    Contouring of targets and normal tissues is one of the largest sources of variability in radiation therapy treatment plans. Contours thus require a time intensive and error-prone quality assurance (QA) evaluation, limitations which also impair the facilitation of adaptive radiotherapy (ART). Here, an automated system for contour QA is developed using historical data (the ‘knowledge base’). A pilot study was performed with a knowledge base derived from 9 contours each from 29 head-and-neck treatment plans. Size, shape, relative position, and other clinically-relevant metrics and heuristically derived rules are determined. Metrics are extracted from input patient data and compared against rules determined from the knowledge base; a computer-learning component allows metrics to evolve with more input data, including patient specific data for ART. Nine additional plans containing 42 unique contouring errors were analyzed. 40/42 errors were detected as were 9 false positives. The results of this study imply knowledge-based contour QA could potentially enhance the safety and effectiveness of RT treatment plans as well as increase the efficiency of the treatment planning process, reducing labor and the cost of therapy for patients. (paper)

  5. Effects of background and contour luminance on the hue and brightness of the Watercolor effect.

    Science.gov (United States)

    Gerardin, Peggy; Dojat, Michel; Knoblauch, Kenneth; Devinck, Frédéric

    2018-03-01

    Conjoint measurement was used to investigate the joint influences of the luminance of the background and the inner contour on hue- and brightness filling-in for a stimulus configuration generating a water-color effect (WCE), i.e., a wiggly bi-chromatic contour enclosing a region with the lower luminance component on the exterior. Two stimuli with the background and inner contour luminances covarying independently were successively presented, and in separate experiments, the observer judged which member of the pair's interior regions contained a stronger hue or was brighter. Braided-contour control stimuli that generated little or no perceptual filling-in were also used to assess whether observers were judging the interior regions and not the contours themselves. Three nested models of the contributions of the background and inner contour to the judgments were fit to the data by maximum likelihood and evaluated by likelihood ratio tests. Both stimulus components contributed to both the hue and brightness of the interior region with increasing luminance of the inner contour generating an assimilative filling-in for the hue judgments but a contrast effect for the brightness judgments. Control analyses showed negligible effects for the order of the luminance of the background or inner contour on the judgments. An additive contribution of both components was rejected in favor of a saturated model in which the responses depended on the levels of both stimulus components. For the hue judgments, increased background luminance led to greater hue filling-in at higher luminances of the interior contour. For the brightness judgments, the higher background luminance generated less brightness filling-in at higher luminances of the interior contour. The results indicate different effects of the inner contour and background on the induction of the brightness and coloration percepts of the WCE, suggesting that they are mediated by different mechanisms. Copyright © 2018 Elsevier

  6. Pulsed-field gel electrophoresis of bacterial chromosomes.

    Science.gov (United States)

    Mawer, Julia S P; Leach, David R F

    2013-01-01

    The separation of fragments of DNA by agarose gel electrophoresis is integral to laboratory life. Nevertheless, standard agarose gel electrophoresis cannot resolve fragments bigger than 50 kb. Pulsed-field gel electrophoresis is a technique that has been developed to overcome the limitations of standard agarose gel electrophoresis. Entire linear eukaryotic chromosomes, or large fragments of a chromosome that have been generated by the action of rare-cutting restriction endonucleases, can be separated using this technique. As a result, pulsed-field gel electrophoresis has many applications, from karyotype analysis of microbial genomes, to the analysis of chromosomal strand breaks and their repair intermediates, to the study of DNA replication and the identification of origins of replication. This chapter presents a detailed protocol for the preparation of Escherichia coli chromosomal DNA that has been embedded in agarose plugs, digested with the rare-cutting endonuclease NotI, and separated by contour-clamped homogeneous field electrophoresis. The principles in this protocol can be applied to the separation of all fragments of DNA whose size range is between 40 kb and 1 Mb.

  7. Contour extraction of echocardiographic images based on pre-processing

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana [Department of Multimedia, Faculty of Computer Science and Information Technology, Department of Computer and Communication Systems Engineering, Faculty of Engineering University Putra Malaysia 43400 Serdang, Selangor (Malaysia); Zamrin, D M [Department of Surgery, Faculty of Medicine, National University of Malaysia, 56000 Cheras, Kuala Lumpur (Malaysia); Saripan, M Iqbal

    2011-02-15

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  8. Contour extraction of echocardiographic images based on pre-processing

    International Nuclear Information System (INIS)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana; Zamrin, D M; Saripan, M Iqbal

    2011-01-01

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  9. After massive weight loss: patients' expectations of body contouring surgery.

    Science.gov (United States)

    Kitzinger, Hugo B; Abayev, Sara; Pittermann, Anna; Karle, Birgit; Bohdjalian, Arthur; Langer, Felix B; Prager, Gerhard; Frey, Manfred

    2012-04-01

    Massive weight loss following bariatric surgery leads to excess skin with functional and aesthetic impairments. Surplus skin can then contribute to problems with additional weight loss or gain. The aims of the current study were to evaluate the frequency of massive soft tissue development in gastric bypass patients, to determine whether males and females experience similar post-bypass body changes, and to learn about the expectations and impairments related to body contouring surgery. A questionnaire addressing information on the satisfaction of body image, quality of life, and expectation of body contouring surgery following massive weight loss was mailed to 425 patients who had undergone gastric bypass surgery between 2003 and 2009. Of these 425 individuals, 252 (59%) patients completed the survey. Ninety percent of women and 88% of men surveyed rated their appearance following massive weight loss as satisfactory, good, or very good. However, 96% of all patients developed surplus skin, which caused intertriginous dermatitis and itching. In addition, patients reported problems with physical activity (playing sports) and finding clothing that fit appropriately. Moreover, 75% of female and 68% of male patients reported desiring body contouring surgery. The most important expectation of body contouring surgery was improved appearance, followed by improved self-confidence and quality of life. Surplus skin resulting from gastric bypass surgery is a common issue that causes functional and aesthetic impairments in patients. Consequently, this increases the desire for body contouring surgery with high expectations for the aesthetic outcome as well as improved life satisfaction.

  10. An evaluation of the contouring abilities of medical dosimetry students for the anatomy of a prostate cancer patient

    International Nuclear Information System (INIS)

    Collins, Kevin S.

    2012-01-01

    Prostate cancer is one of the most common diseases treated in a radiation oncology department. One of the major predictors of the treatment outcome and patient side effects is the accuracy of the anatomical contours for the treatment plan. Therefore, the purpose of this study was to determine which anatomical structures are most often contoured correctly and incorrectly by medical dosimetry students. The author also wanted to discover whether a review of the contouring rules would increase contouring accuracy. To achieve this, a male computed tomography dataset consisting of 72 transverse slices was sent to students for contouring. The students were instructed to import this dataset into their treatment planning system and contour the following structures: skin, bladder, rectum, prostate, penile bulb, seminal vesicles, left femoral head, and right femoral head. Upon completion of the contours, the contour file was evaluated against a “gold standard” contour set using StructSure software (Standard Imaging, Inc). A review of the initial contour results was conducted and then students were instructed to contour the dataset a second time. The results of this study showed significant differences between contouring sessions. These results and the standardization of contouring rules should benefit all individuals who participate in the treatment planning of cancer patients.

  11. The inter-relationship between the periodontium and contours of artificial crowns

    International Nuclear Information System (INIS)

    Fareed, K.; Omar, R.

    1989-01-01

    The subject of axial contour of artificial crowns has and continues to be highly controversial. Much of the controversy centers arounrj whether the gingival sulcus is really in need of protection from buccal and/or lingual convexities, or whether a flatter emergence profile affords self cleansing muscle action. Evidence is reviewed in this part which suggests that overcontouring is probably more detrimental to gingival health than undercontouring. The critical role played by proper tooth reduction in attaining correct axial contour is shown and a rationale presented for the important interplay between preparation design, properties of the restorative materials to be employed and physiologic contour. (author)

  12. Calf Contouring with Endoscopic Fascial Release, Calf Implant, and Structural Fat Grafting

    Directory of Open Access Journals (Sweden)

    Ercan Karacaoglu, MD

    2013-08-01

    Conclusions: A novel endoscopic approach for lower leg contouring is discussed. Endoscopic fasciotomy technique with calf implant and structural fat grafting for improved lower leg aesthetics is a simple, effective, reliable, and predictable technique for calf contouring.

  13. Robust iterative learning contouring controller with disturbance observer for machine tool feed drives.

    Science.gov (United States)

    Simba, Kenneth Renny; Bui, Ba Dinh; Msukwa, Mathew Renny; Uchiyama, Naoki

    2018-04-01

    In feed drive systems, particularly machine tools, a contour error is more significant than the individual axial tracking errors from the view point of enhancing precision in manufacturing and production systems. The contour error must be within the permissible tolerance of given products. In machining complex or sharp-corner products, large contour errors occur mainly owing to discontinuous trajectories and the existence of nonlinear uncertainties. Therefore, it is indispensable to design robust controllers that can enhance the tracking ability of feed drive systems. In this study, an iterative learning contouring controller consisting of a classical Proportional-Derivative (PD) controller and disturbance observer is proposed. The proposed controller was evaluated experimentally by using a typical sharp-corner trajectory, and its performance was compared with that of conventional controllers. The results revealed that the maximum contour error can be reduced by about 37% on average. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    Science.gov (United States)

    Odille, Freddy; Bustin, Aurélien; Liu, Shufang; Chen, Bailiang; Vuissoz, Pierre-André; Felblinger, Jacques; Bonnemains, Laurent

    2018-05-01

    Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine datasets; reformatted slices are then used to optimize the manual segmentation workflow. Isotropic 3D cine datasets were obtained from multiple 2D cine stacks (acquired during free-breathing in SAX and long-axis (LAX) orientations) using nonrigid motion correction (cine-GRICS method) and super-resolution. Several manual segmentation strategies were then compared, including conventional SAX segmentation, LAX segmentation in three views only, and combinations of SAX and LAX slices. An implicit B-spline surface reconstruction algorithm is proposed to reconstruct the left ventricular cavity surface from the sparse set of 2D contours. All tested sparse segmentation strategies were in good agreement, with Dice scores above 0.9 despite using fewer slices (3-6 sparse slices instead of 8-10 contiguous SAX slices). When compared to independent phase-contrast flow measurements, stroke volumes computed from four or six sparse slices had slightly higher precision than conventional SAX segmentation (error standard deviation of 5.4 mL against 6.1 mL) at the cost of slightly lower accuracy (bias of -1.2 mL against 0.2 mL). Functional parameters also showed a trend to improved precision, including end-diastolic volumes, end-systolic volumes, and ejection fractions). The postprocessing workflow of 3D isotropic cardiac imaging strategies can be optimized using sparse segmentation and 3D surface reconstruction. Magn Reson Med 79:2665-2675, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Technical report on the surface reconstruction of stacked contours by using the commercial software

    Science.gov (United States)

    Shin, Dong Sun; Chung, Min Suk; Hwang, Sung Bae; Park, Jin Seo

    2007-03-01

    After drawing and stacking contours of a structure, which is identified in the serially sectioned images, three-dimensional (3D) image can be made by surface reconstruction. Usually, software is composed for the surface reconstruction. In order to compose the software, medical doctors have to acquire the help of computer engineers. So in this research, surface reconstruction of stacked contours was tried by using commercial software. The purpose of this research is to enable medical doctors to perform surface reconstruction to make 3D images by themselves. The materials of this research were 996 anatomic images (1 mm intervals) of left lower limb, which were made by serial sectioning of a cadaver. On the Adobe Photoshop, contours of 114 anatomic structures were drawn, which were exported to Adobe Illustrator files. On the Maya, contours of each anatomic structure were stacked. On the Rhino, superoinferior lines were drawn along all stacked contours to fill quadrangular surfaces between contours. On the Maya, the contours were deleted. 3D images of 114 anatomic structures were assembled with their original locations preserved. With the surface reconstruction technique, developed in this research, medical doctors themselves could make 3D images of the serially sectioned images such as CTs and MRIs.

  16. Mandibular marginal contouring in oriental aesthetic surgery: refined surgical concept and operative procedure.

    Science.gov (United States)

    Satoh, Kaneshige; Mitsukawa, Nobuyuki

    2014-05-01

    In aesthetic mandibular contouring surgery, which is often conducted in Asians, the operative procedure is thought to deliver a more aesthetic mandibular shape by means of contouring conducted as a whole from the ramus to the symphysis. The authors describe the refined concept and operative procedures of mandibular marginal contouring. For the 7-year period from 2004 to 2011, mandibular marginal contouring has been used in 57 consecutive series of Japanese subjects. Patient ages ranged from 18 to 33 years, and the subjects included 15 men and 42 women. The surgery was carried out by cutting off the protruding deformed mandibular margin from the ramus to the symphysis. In 53 of 57 cases, the focus was on angle contouring. Concomitant genioplasty by horizontal osteotomy of the chin was conducted in 42 of 57 cases (recession, advancement, shortening, elongation, and correction of the shift variously). In 22 materials exhibiting bulk around the mandibular, the ramus to the body was excised sagittally and thinned. In all the patients, mandibular marginal contouring from the ramus to the symphysis was completed. Partial masseter muscle resection was conducted in 11 of 57 cases. Mandibular contouring effectively achieved a highly satisfactory result in all cases. The upper portion of the peripheral branch of the trunk of the mental nerve was dissected by an electric scalpel in 1 case but sutured immediately using an 8-0 nylon stitch. Transient palsy of the mental nerve was noticed in a few cases but subsided in 1 to 2 months. No particular complications were encountered. No secondary revision was required in this series. In mandibular angle plasty, mandibular marginal contouring from the ramus to the symphysis should be carried out by cutting off the angle keeping in mind the entire mandibular shape. This concept and the procedure can deliver greater patient satisfaction.

  17. Pre- and postoperative quantitative analysis of contour abnormalities in Graves upper eyelid retraction.

    Science.gov (United States)

    Ribeiro, Sara F T; Milbratz, Gherusa H; Garcia, Denny M; Devoto, Martin; Guilherme Neto, H; Mörschbächer, Ricardo; Pereira, Filipe J; Cruz, Antonio A V

    2012-01-01

    One of the most common problems of the surgical management of Graves upper eyelid retraction is the occurrence of eyelid contour abnormalities. In the present study, the postoperative contour of a large sample of eyelids of patients with Graves orbitopathy was measured. The postoperative upper eyelid contour of 62 eyes of 43 patients with Graves orbitopathy was subjectively classified by 3 experienced surgeons in 3 categories: poor, fair, and good. The shape of the eyelid contours in each category was then measured with a recently developed custom-made software by measuring multiple midpupil eyelid distances each 15° along the palpebral fissure. The upper eyelid contour of 60 normal subjects was also quantified as a control group. The mean ratio between the sum of the lateral and medial midpupil eyelid distances (lateral/medial ratio) was 1.10 ± 0.11 standard deviation in controls and 1.15 ± 0.13 standard deviation in patients. Postoperatively, the mean midpupil eyelid distance at 90° was 4.16 ± 1.13 mm standard deviation. The distribution lateral/medial ratios of the eyelids judged as having good contours was similar to the distribution of the controls with a modal value centered on the interval between 1.0 and 1.10. The distribution of lateral/medial ratios of the eyelids judged as having poor contour was bimodal, with eyelids with low and high lateral/medial ratios. Low lateral/medial ratios occurred when there was a lateral overcorrection, giving the eyelid a flat or a medial ptosis appearance. High lateral/medial ratios were due to a central or medial overcorrection or a lateral peak maintenance. Postoperative upper eyelid contour abnormalities can be quantified by comparing the sum of multiple midpupil eyelid distances of the lateral and medial sectors of the eyelid. Low and high lateral/medial ratios are anomalous and judged as unpleasant.

  18. The Main Cognitive Model of Visual Recognition: Contour Recognition

    OpenAIRE

    Chen, YongHong

    2017-01-01

    In this paper, we will study the following pattern recognition problem: Every pattern is a 3-dimensional graph, its surface can be split up into some regions, every region is composed of the pixels with the approximately same colour value and the approximately same depth value that is distance to eyes, and there may also be some contours, e.g., literal contours, on a surface of every pattern. For this problem we reveal the inherent laws. Moreover, we establish a cognitive model to reflect the...

  19. Complications following body contouring surgery after massive weight loss

    DEFF Research Database (Denmark)

    Hasanbegovic, Emir; Sørensen, Jens Ahm

    2014-01-01

    Bariatric surgery is a way to achieve lasting weight loss in the obese. Body contouring surgery seeks to alleviate some of the discomfort caused by the excessive loose skin following massive weight loss. Higher complication rates are described in this type of surgery when done post......-bariatric. The purpose of this article is to compare complication rates of body contouring surgery when performed on patients with weight loss due to bariatric surgery compared to patients who lost weight due to dietary changes and/or exercise....

  20. Non-contact detection of cardiac rate based on visible light imaging device

    Science.gov (United States)

    Zhu, Huishi; Zhao, Yuejin; Dong, Liquan

    2012-10-01

    We have developed a non-contact method to detect human cardiac rate at a distance. This detection is based on the general lighting condition. Using the video signal of human face region captured by webcam, we acquire the cardiac rate based on the PhotoPlethysmoGraphy theory. In this paper, the cardiac rate detecting method is mainly in view of the blood's different absorptivities of the lights various wavelengths. Firstly, we discompose the video signal into RGB three color signal channels and choose the face region as region of interest to take average gray value. Then, we draw three gray-mean curves on each color channel with time as variable. When the imaging device has good fidelity of color, the green channel signal shows the PhotoPlethysmoGraphy information most clearly. But the red and blue channel signals can provide more other physiological information on the account of their light absorptive characteristics of blood. We divide red channel signal by green channel signal to acquire the pulse wave. With the passband from 0.67Hz to 3Hz as a filter of the pulse wave signal and the frequency spectrum superimposed algorithm, we design frequency extracted algorithm to achieve the cardiac rate. Finally, we experiment with 30 volunteers, containing different genders and different ages. The results of the experiments are all relatively agreeable. The difference is about 2bmp. Through the experiment, we deduce that the PhotoPlethysmoGraphy theory based on visible light can also be used to detect other physiological information.

  1. Brightness Alteration with Interweaving Contours

    Directory of Open Access Journals (Sweden)

    Sergio Roncato

    2012-12-01

    Full Text Available Chromatic induction is observed whenever the perceived colour of a target surface shifts towards the hue of a neighbouring surface. Some vivid manifestations may be seen in a white background where thin coloured lines have been drawn (assimilation or when lines of different colours are collinear (neon effect or adjacent (watercolour to each other. This study examines a particular colour induction that manifests in concomitance with an opposite effect of colour saturation (or anti-spread. The two phenomena can be observed when a repetitive pattern is drawn in which outline thin contours intercept wider contours or surfaces, colour spreading appear to fill the surface occupied by surfaces or thick lines whereas the background traversed by thin lines is seen as brighter or filled of a saturated white. These phenomena were first observed by Bozzi (1975 and Kanizsa (1979 in figural conditions that did not allow them to document their conjunction. Here we illustrate various manifestations of this twofold phenomenon and compare its effects with the known effects of brightness and colour induction. Some conjectures on the nature of these effects are discussed.

  2. Intramyocardial strain estimation from cardiac cine MRI.

    Science.gov (United States)

    Elnakib, Ahmed; Beache, Garth M; Gimel'farb, Georgy; El-Baz, Ayman

    2015-08-01

    Functional strain is one of the important clinical indicators for the quantification of heart performance and the early detection of cardiovascular diseases, and functional strain parameters are used to aid therapeutic decisions and follow-up evaluations after cardiac surgery. A comprehensive framework for deriving functional strain parameters at the endocardium, epicardium, and mid-wall of the left ventricle (LV) from conventional cine MRI data was developed and tested. Cine data were collected using short TR-/TE-balanced steady-state free precession acquisitions on a 1.5T Siemens Espree scanner. The LV wall borders are segmented using a level set-based deformable model guided by a stochastic force derived from a second-order Markov-Gibbs random field model that accounts for the object shape and appearance features. Then, the mid-wall of the segmented LV is determined based on estimating the centerline between the endocardium and epicardium of the LV. Finally, a geometrical Laplace-based method is proposed to track corresponding points on successive myocardial contours throughout the cardiac cycle in order to characterize the strain evolutions. The method was tested using simulated phantom images with predefined point locations of the LV wall throughout the cardiac cycle. The method was tested on 30 in vivo datasets to evaluate the feasibility of the proposed framework to index functional strain parameters. The cine MRI-based model agreed with the ground truth for functional metrics to within 0.30 % for indexing the peak systolic strain change and 0.29 % (per unit time) for indexing systolic and diastolic strain rates. The method was feasible for in vivo extraction of functional strain parameters. Strain indexes of the endocardium, mid-wall, and epicardium can be derived from routine cine images using automated techniques, thereby improving the utility of cine MRI data for characterization of myocardial function. Unlike traditional texture-based tracking, the

  3. Contours, 2 foot contours automatically generated from 2008 LIDAR for the purpose of supporting FEMA floodplain mapping. Limited manual editing, breaklines for waterbodies greater than 5 acres created and use.10' index contours labeled., Published in 2008, 1:1200 (1in=100ft) scale, City of Portage Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Contours dataset current as of 2008. 2 foot contours automatically generated from 2008 LIDAR for the purpose of supporting FEMA floodplain mapping. Limited manual...

  4. Optimized extraction of polysaccharides from corn silk by pulsed electric field and response surface quadratic design.

    Science.gov (United States)

    Zhao, Wenzhu; Yu, Zhipeng; Liu, Jingbo; Yu, Yiding; Yin, Yongguang; Lin, Songyi; Chen, Feng

    2011-09-01

    Corn silk is a traditional Chinese herbal medicine, which has been widely used for treatment of some diseases. In this study the effects of pulsed electric field on the extraction of polysaccharides from corn silk were investigated. Polysaccharides in corn silk were extracted by pulsed electric field and optimized by response surface methodology (RSM), based on a Box-Behnken design (BBD). Three independent variables, including electric field intensity (kV cm(-1) ), ratio of liquid to raw material and pulse duration (µs), were investigated. The experimental data were fitted to a second-order polynomial equation and also profiled into the corresponding 3-D contour plots. Optimal extraction conditions were as follows: electric field intensity 30 kV cm(-1) , ratio of liquid to raw material 50, and pulse duration 6 µs. Under these condition, the experimental yield of extracted polysaccharides was 7.31% ± 0.15%, matching well with the predicted value. The results showed that a pulsed electric field could be applied to extract value-added products from foods and/or agricultural matrix. Copyright © 2011 Society of Chemical Industry.

  5. I/O-Efficient Algorithms for Computing Contour Lines on a Terrain

    DEFF Research Database (Denmark)

    Agarwal, Pankaj Kumar; Arge, Lars; Sadri, Bardia

    2008-01-01

    A terrain M is the graph of a bivariate function. We assume that M is represented as a triangulated surface with N vertices. A contour (or isoline) of M is a connected component of a level set of M. Generically, each contour is a closed polygonal curve; at "critical" levels these curves may touch...

  6. Maintaining Contour Trees of Dynamic Terrains

    DEFF Research Database (Denmark)

    Agarwal, Pankaj K.; Mølhave, Thomas; Revsbæk, Morten

    2015-01-01

    We study the problem of maintaining the contour tree T of a terrain Sigma, represented as a triangulated xy-monotone surface, as the heights of its vertices vary continuously with time. We characterize the combinatorial changes in T and how they relate to topological changes in Sigma. We present ...

  7. A phantom study of tumor contouring on PET imaging

    International Nuclear Information System (INIS)

    Chen Song; Li Xuena; Li Yaming; Yin Yafu; Li Na; Han Chunqi

    2010-01-01

    Objective: To explore an algorithm to define the threshold value for tumor contouring on 18 F-fluorodeoxyglucose (FDG) PET imaging. Methods: A National Electrical Manufacturing Association (NEMA)NU 2 1994 PET phantom with 5 spheres of different diameters were filled with 18 F-FDG. Seven different sphere-to-background ratios were obtained and the phantom was scanned by Discovery LS 4. For each sphere-to-background ratio, the maximum standardized uptake value (SUV max ) of each sphere, the SUV of the border of each sphere (SUV border ), the mean SUV of a 1 cm region of background (SUV bg ) and the diameter (D) of each sphere were measured. SPSS 13.0 software was used for curve fitting and regression analysis to obtain the threshold algorithm. The calculated thresholds were applied to delineate 29 pathologically confirmed lung cancer lesions on PET images and the obtained volumes were compared with the volumes contoured on CT images in lung window. Results: The algorithm for defining contour threshold is TH% = 33.1% + 46.8% SUV bg /SUV max + 13.9%/D (r = 0.994) by phantom studies. For 29 lung cancer lesions, the average gross tumor volumes (GTV) delineated on PET and CT are (7.36±1.62) ml and (8.31±2.05) ml, respectively (t = -1.26, P>0.05). Conclusion: The proposed threshold algorithm for tumor contouring on PET image could provide comparable GTV with CT. (authors)

  8. Direct Optimization of Printed Reflectarrays for Contoured Beam Satellite Antenna Applications

    DEFF Research Database (Denmark)

    Zhou, Min; Sorensen, Stig B.; Kim, Oleksiy S.

    2013-01-01

    An accurate and efficient direct optimization technique for the design of contoured beam reflectarrays is presented. It is based on the spectral domain method of moments assuming local periodicity and minimax optimization. Contrary to the conventional phase-only optimization techniques, the geome......An accurate and efficient direct optimization technique for the design of contoured beam reflectarrays is presented. It is based on the spectral domain method of moments assuming local periodicity and minimax optimization. Contrary to the conventional phase-only optimization techniques......, the geometrical parameters of the array elements are directly optimized to fulfill the contoured beam requirements, thus maintaining a direct relation between optimization goals and optimization variables, and hence resulting in more optimal designs. Both co- and cross-polar radiation patterns of the reflectarray...... can be optimized for multiple frequencies, polarizations, and feed illuminations. Several contoured beam reflectarrays, that radiate a high-gain beam on a European coverage, have been designed and compared to similar designs obtained using the phase-only optimization technique. The comparisons show...

  9. Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

    International Nuclear Information System (INIS)

    Wu, Abraham J.; Bosch, Walter R.; Chang, Daniel T.; Hong, Theodore S.; Jabbour, Salma K.; Kleinberg, Lawrence R.; Mamon, Harvey J.; Thomas, Charles R.; Goodman, Karyn A.

    2015-01-01

    Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future

  10. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    Science.gov (United States)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  11. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    LENUS (Irish Health Repository)

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient\\'s cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless

  12. A novel approach to dual excitation ratiometric optical mapping of cardiac action potentials with di-4-ANEPPS using pulsed LED excitation.

    Science.gov (United States)

    Bachtel, Andrew D; Gray, Richard A; Stohlman, Jayna M; Bourgeois, Elliot B; Pollard, Andrew E; Rogers, Jack M

    2011-07-01

    We developed a new method for ratiometric optical mapping of transmembrane potential (V(m)) in cardiac preparations stained with di-4-ANEPPS. V(m)-dependent shifts of excitation and emission spectra establish two excitation bands (481 nm) that produce fluorescence changes of opposite polarity within a single emission band (575-620 nm). The ratio of these positive and negative fluorescence signals (excitation ratiometry) increases V(m) sensitivity and removes artifacts common to both signals. We pulsed blue (450 ± 10 nm) and cyan (505 ± 15 nm) light emitting diodes (LEDs) at 375 Hz in alternating phase synchronized to a camera (750 frames-per-second). Fluorescence was bandpass filtered (585 ± 20 nm). This produced signals with upright (blue) and inverted (cyan) action potentials (APs) interleaved in sequential frames. In four whole swine hearts with motion chemically arrested, fractional fluorescence for blue, cyan, and ratio signals was 1.2 ± 0.3%, 1.2 ± 0.3%, and 2.4 ± 0.6%, respectively. Signal-to-noise ratios were 4.3 ± 1.4, 4.0 ± 1.2, and 5.8 ± 1.9, respectively. After washing out the electromechanical uncoupling agent, we characterized motion artifact by cross-correlating blue, cyan, and ratio signals with a signal with normal AP morphology. Ratiometry improved cross-correlation coefficients from 0.50 ± 0.48 to 0.81 ± 0.25, but did not cancel all motion artifacts. These findings demonstrate the feasibility of pulsed LED excitation ratiometry in myocardium. © 2011 IEEE

  13. Kepler Planet Detection Metrics: Per-Target Detection Contours for Data Release 25

    Science.gov (United States)

    Burke, Christopher J.; Catanzarite, Joseph

    2017-01-01

    A necessary input to planet occurrence calculations is an accurate model for the pipeline completeness (Burke et al., 2015). This document describes the use of the Kepler planet occurrence rate products in order to calculate a per-target detection contour for the measured Data Release 25 (DR25) pipeline performance. A per-target detection contour measures for a given combination of orbital period, Porb, and planet radius, Rp, what fraction of transit signals are recoverable by the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017). The steps for calculating a detection contour follow the procedure outlined in Burke et al. (2015), but have been updated to provide improved accuracy enabled by the substantially larger database of transit injection and recovery tests that were performed on the final version (i.e., SOC 9.3) of the Kepler pipeline (Christiansen, 2017; Burke Catanzarite, 2017a). In the following sections, we describe the main inputs to the per-target detection contour and provide a worked example of the python software released with this document (Kepler Planet Occurrence Rate Tools KeplerPORTs)1 that illustrates the generation of a detection contour in practice. As background material for this document and its nomenclature, we recommend the reader be familiar with the previous method of calculating a detection contour (Section 2 of Burke et al.,2015), input parameters relevant for describing the data quantity and quality of Kepler targets (Burke Catanzarite, 2017b), and the extensive new transit injection and recovery tests of the Kepler pipeline (Christiansen et al., 2016; Burke Catanzarite, 2017a; Christiansen, 2017).

  14. An automatic contour propagation method to follow parotid gland deformation during head-and-neck cancer tomotherapy

    International Nuclear Information System (INIS)

    Faggiano, E; Scalco, E; Rizzo, G; Fiorino, C; Broggi, S; Cattaneo, M; Maggiulli, E; Calandrino, R; Dell'Oca, I; Di Muzio, N

    2011-01-01

    We developed an efficient technique to auto-propagate parotid gland contours from planning kVCT to daily MVCT images of head-and-neck cancer patients treated with helical tomotherapy. The method deformed a 3D surface mesh constructed from manual kVCT contours by B-spline free-form deformation to generate optimal and smooth contours. Deformation was calculated by elastic image registration between kVCT and MVCT images. Data from ten head-and-neck cancer patients were considered and manual contours by three observers were included in both kVCT and MVCT images. A preliminary inter-observer variability analysis demonstrated the importance of contour propagation in tomotherapy application: a high variability was reported in MVCT parotid volume estimation (p = 0.0176, ANOVA test) and a larger uncertainty of MVCT contouring compared with kVCT was demonstrated by DICE and volume variability indices (Wilcoxon signed rank test, p -4 for both indices). The performance analysis of our method showed no significant differences between automatic and manual contours in terms of volumes (p > 0.05, in a multiple comparison Tukey test), center-of-mass distances (p = 0.3043, ANOVA test), DICE values (p = 0.1672, Wilcoxon signed rank test) and average and maximum symmetric distances (p = 0.2043, p = 0.8228 Wilcoxon signed rank tests). Results suggested that our contour propagation method could successfully substitute human contouring on MVCT images.

  15. An automatic contour propagation method to follow parotid gland deformation during head-and-neck cancer tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Faggiano, E; Scalco, E; Rizzo, G [Istituto di Bioimmagini e Fisiologia Molecolare (IBFM), CNR, Milan (Italy); Fiorino, C; Broggi, S; Cattaneo, M; Maggiulli, E; Calandrino, R [Department of Medical Physics, San Raffaele Scientific Institute, Milan (Italy); Dell' Oca, I; Di Muzio, N, E-mail: fiorino.claudio@hsr.it [Department of Radiotherapy, San Raffaele Scientific Institute, Milan (Italy)

    2011-02-07

    We developed an efficient technique to auto-propagate parotid gland contours from planning kVCT to daily MVCT images of head-and-neck cancer patients treated with helical tomotherapy. The method deformed a 3D surface mesh constructed from manual kVCT contours by B-spline free-form deformation to generate optimal and smooth contours. Deformation was calculated by elastic image registration between kVCT and MVCT images. Data from ten head-and-neck cancer patients were considered and manual contours by three observers were included in both kVCT and MVCT images. A preliminary inter-observer variability analysis demonstrated the importance of contour propagation in tomotherapy application: a high variability was reported in MVCT parotid volume estimation (p = 0.0176, ANOVA test) and a larger uncertainty of MVCT contouring compared with kVCT was demonstrated by DICE and volume variability indices (Wilcoxon signed rank test, p < 10{sup -4} for both indices). The performance analysis of our method showed no significant differences between automatic and manual contours in terms of volumes (p > 0.05, in a multiple comparison Tukey test), center-of-mass distances (p = 0.3043, ANOVA test), DICE values (p = 0.1672, Wilcoxon signed rank test) and average and maximum symmetric distances (p = 0.2043, p = 0.8228 Wilcoxon signed rank tests). Results suggested that our contour propagation method could successfully substitute human contouring on MVCT images.

  16. Development of a tool-kit for the detection of healthy and injured cardiac tissue based on MR imaging

    Directory of Open Access Journals (Sweden)

    Westphal Philip

    2017-09-01

    Full Text Available Planning of interventions to treat cardiac arrhythmia requires a 3D patient specific model of the heart. Currently available commercial or free software dedicated to this task have important limitations for routinely use. Automatic algorithms are not robust enough while manual methods are time-consuming. Therefore, the project attempts to develop an optimal software tool. The heart model is generated from preoperative MR data-sets acquired with contrast agent and allows visualisation of damaged cardiac tissue. A requirement in the development of the software tool was the use of semi-automatic functions to be more robust. Once the patient image dataset has been loaded, the user selects a region of interest. Thresholding functions allow selecting the areas of high intensities which correspond to anatomical structures filled with contrast agent, namely cardiac cavities and blood vessels. Thereafter, the target-structure, for example the left ventricle, is coarsely selected by interactively outlining the gross shape. An active contour function adjusts automatically the initial contour to the image content. The result can still be manually improved using fast interaction tools. Finally, possible scar tissue located in the cavity muscle is automatically detected and visualized on the 3D heart model. The model is exported in format which is compatible with interventional devices at hospital. The evaluation of the software tool included two steps. Firstly, a comparison with two free software tools was performed on two image data sets of variable quality. Secondly, six scientists and physicians tested our tool and filled out a questionnaire. The performance of our software tool was visually judged more satisfactory than the free software, especially on the data set of lower quality. Professionals evaluated positively our functionalities regarding time taken, ease of use and quality of results. Improvements would consist in performing the planning based

  17. Self-adaptive method to distinguish inner and outer contours of industrial computed tomography image for rapid prototype

    International Nuclear Information System (INIS)

    Duan Liming; Ye Yong; Zhang Xia; Zuo Jian

    2013-01-01

    A self-adaptive identification method is proposed for realizing more accurate and efficient judgment about the inner and outer contours of industrial computed tomography (CT) slice images. The convexity-concavity of the single-pixel-wide closed contour is identified with angle method at first. Then, contours with concave vertices are distinguished to be inner or outer contours with ray method, and contours without concave vertices are distinguished with extreme coordinate value method. The method was chosen to automatically distinguish contours by means of identifying the convexity and concavity of the contours. Thus, the disadvantages of single distinguishing methods, such as ray method's time-consuming and extreme coordinate method's fallibility, can be avoided. The experiments prove the adaptability, efficiency, and accuracy of the self-adaptive method. (authors)

  18. Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists

    Energy Technology Data Exchange (ETDEWEB)

    Baldini, Elizabeth H., E-mail: ebaldini@partners.org [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Abrams, Ross A. [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Bosch, Walter [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States); Roberge, David [Department of Radiation Oncology, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Haas, Rick L.M. [Department of Radiotherapy, Netherlands Cancer Institute, Amsterdam (Netherlands); Catton, Charles N. [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Indelicato, Daniel J. [Department of Radiation Oncology, University of Florida Medical Center, Jacksonville, Florida (United States); Olsen, Jeffrey R. [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States); Deville, Curtiland [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Chen, Yen-Lin [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Finkelstein, Steven E. [Translational Research Consortium, 21st Century Oncology, Scottsdale, Arizona (United States); DeLaney, Thomas F. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Wang, Dian [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States)

    2015-08-01

    Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed.

  19. Can Images Obtained With High Field Strength Magnetic Resonance Imaging Reduce Contouring Variability of the Prostate?

    International Nuclear Information System (INIS)

    Usmani, Nawaid; Sloboda, Ron; Kamal, Wafa; Ghosh, Sunita; Pervez, Nadeem; Pedersen, John; Yee, Don; Danielson, Brita; Murtha, Albert; Amanie, John; Monajemi, Tara

    2011-01-01

    Purpose: The objective of this study is to determine whether there is less contouring variability of the prostate using higher-strength magnetic resonance images (MRI) compared with standard MRI and computed tomography (CT). Methods and Materials: Forty patients treated with prostate brachytherapy were accrued to a prospective study that included the acquisition of 1.5-T MR and CT images at specified time points. A subset of 10 patients had additional 3.0-T MR images acquired at the same time as their 1.5-T MR scans. Images from each of these patients were contoured by 5 radiation oncologists, with a random subset of patients repeated to quantify intraobserver contouring variability. To minimize bias in contouring the prostate, the image sets were placed in folders in a random order with all identifiers removed from the images. Results: Although there was less interobserver contouring variability in the overall prostate volumes in 1.5-T MRI compared with 3.0-T MRI (p < 0.01), there was no significant differences in contouring variability in the different regions of the prostate between 1.5-T MRI and 3.0-T MRI. MRI demonstrated significantly less interobserver contouring variability in both 1.5-T and 3.0-T compared with CT in overall prostate volumes (p < 0.01, p = 0.01), with the greatest benefits being appreciated in the base of the prostate. Overall, there was less intraobserver contouring variability than interobserver contouring variability for all of the measurements analyzed. Conclusions: Use of 3.0-T MRI does not demonstrate a significant improvement in contouring variability compared with 1.5-T MRI, although both magnetic strengths demonstrated less contouring variability compared with CT.

  20. Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists

    International Nuclear Information System (INIS)

    Baldini, Elizabeth H.; Abrams, Ross A.; Bosch, Walter; Roberge, David; Haas, Rick L.M.; Catton, Charles N.; Indelicato, Daniel J.; Olsen, Jeffrey R.; Deville, Curtiland; Chen, Yen-Lin; Finkelstein, Steven E.; DeLaney, Thomas F.; Wang, Dian

    2015-01-01

    Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed

  1. Poster - Thur Eve - 65: Optimization of an automatic image contouring system for radiation therapy.

    Science.gov (United States)

    Hamilton, T; Nedialkov, N; Wierzbicki, M

    2012-07-01

    Intensity modulated radiation therapy (IMRT) is an advanced technique used to concentrate the prescribed dose in the tumour while minimizing exposure to healthy tissues. Success in IMRT is greatly dependent upon the localization of the target volume and normal tissue, thus accurate contouring is crucial. In this paper, we describe an automated atlas-based image contouring system and our approach for improving the system by performing a full-scale optimization of registration parameters using high-performance computing. To achieve this, we use manually pre-contoured CT images of ten head and neck patients. For any parameter set, each patient data is registered with the remaining patients. Accuracy of the resulting contours is determined automatically by comparing their overlap with manually defined targets using Dice's similarity coefficient (DSC). This allows us to compare all permutations of the image registration parameter sets and input data to investigate their impact on final contour accuracy. Investigating the parameter space required 27,000 image registrations and 216,000 DSC computations. To perform these registrations we introduced a large cluster of high-performance computers and developed a parallel testing harness. The metrics collected from the tests show a wide range of performance, indicating that parameter selection is crucial in our contouring system. By selecting an optimized parameter set, we increased the mean overlap of the automatically contoured regions of interest by 50% and reduced registration time by 50% compared to the original parameters. Our findings illustrate that full-scale optimization is an effective method for improving the performance of the automated image contouring system. © 2012 American Association of Physicists in Medicine.

  2. Principle and realization of segmenting contour series algorithm in reverse engineering based on X-ray computerized tomography

    International Nuclear Information System (INIS)

    Wang Yanfang; Liu Li; Yan Yonglian; Shan Baoci; Tang Xiaowei

    2007-01-01

    A new algorithm of segmenting contour series of images is presented, which can achieve three dimension reconstruction with parametric recognition in Reverse Engineering based on X-ray CT. First, in order to get the nested relationship between contours, a method of a certain angle ray is used. Second, for realizing the contour location in one slice, another approach is presented to generate the contour tree by scanning the relevant vector only once. Last, a judge algorithm is put forward to accomplish the contour match between slices by adopting the qualitative and quantitative properties. The example shows that this algorithm can segment contour series of CT parts rapidly and precisely. (authors)

  3. Inner and outer coronary vessel wall segmentation from CCTA using an active contour model with machine learning-based 3D voxel context-aware image force

    Science.gov (United States)

    Sivalingam, Udhayaraj; Wels, Michael; Rempfler, Markus; Grosskopf, Stefan; Suehling, Michael; Menze, Bjoern H.

    2016-03-01

    In this paper, we present a fully automated approach to coronary vessel segmentation, which involves calcification or soft plaque delineation in addition to accurate lumen delineation, from 3D Cardiac Computed Tomography Angiography data. Adequately virtualizing the coronary lumen plays a crucial role for simulating blood ow by means of fluid dynamics while additionally identifying the outer vessel wall in the case of arteriosclerosis is a prerequisite for further plaque compartment analysis. Our method is a hybrid approach complementing Active Contour Model-based segmentation with an external image force that relies on a Random Forest Regression model generated off-line. The regression model provides a strong estimate of the distance to the true vessel surface for every surface candidate point taking into account 3D wavelet-encoded contextual image features, which are aligned with the current surface hypothesis. The associated external image force is integrated in the objective function of the active contour model, such that the overall segmentation approach benefits from the advantages associated with snakes and from the ones associated with machine learning-based regression alike. This yields an integrated approach achieving competitive results on a publicly available benchmark data collection (Rotterdam segmentation challenge).

  4. Closed contour fractal dimension estimation by the Fourier transform

    International Nuclear Information System (INIS)

    Florindo, J.B.; Bruno, O.M.

    2011-01-01

    Highlights: → A novel fractal dimension concept, based on Fourier spectrum, is proposed. → Computationally simple. Computational time smaller than conventional fractal methods. → Results are closer to Hausdorff-Besicovitch than conventional methods. → The method is more accurate and robustness to geometric operations and noise addition. - Abstract: This work proposes a novel technique for the numerical calculus of the fractal dimension of fractal objects which can be represented as a closed contour. The proposed method maps the fractal contour onto a complex signal and calculates its fractal dimension using the Fourier transform. The Fourier power spectrum is obtained and an exponential relation is verified between the power and the frequency. From the parameter (exponent) of the relation, is obtained the fractal dimension. The method is compared to other classical fractal dimension estimation methods in the literature, e.g., Bouligand-Minkowski, box-counting and classical Fourier. The comparison is achieved by the calculus of the fractal dimension of fractal contours whose dimensions are well-known analytically. The results showed the high precision and robustness of the proposed technique.

  5. Heavy ion scattering in 3D TDHF. [Isodensity contours

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, M.S.

    1977-09-01

    Results of three-dimensional (3D) time-dependent Hartree--Fock (TDHF) calculations are presented. The assumptions used in the calculations are summarized. The first reaction considered is /sup 16/O + /sup 16/O at 105 MeV (lab); isodensity contours integrated perpendicular to the reaction plane are shown for several impact parameters as a function of time. Trajectories are also shown, and the kinetics of the reaction is discussed; several other energies were also examined. Most of the deeply inelastic scattering seems to come from small impact parameters. Density contours and trajectories are next shown for /sup 40/Ca + /sup 40/Ca at 278 MeV (lab). Finally, density contours are shown for asymmetric systems: /sup 4/He + /sup 16/O at l = 5 h-bar and 50 MeV (lab) and /sup 16/O + /sup 40/Ca at l = 20, 40, 60, 80 h-bar and 315 MeV (lab). The light fragment seems to maintain the same average number of nucleons with which it started. 25 figures. (RWR)

  6. Vascular Stiffness and Increased Pulse Pressure in the Aging Cardiovascular System

    Directory of Open Access Journals (Sweden)

    Jochen Steppan

    2011-01-01

    Full Text Available Aging leads to a multitude of changes in the cardiovascular system, including systolic hypertension, increased central vascular stiffness, and increased pulse pressure. In this paper we will review the effects of age-associated increased vascular stiffness on systolic blood pressure, pulse pressure, augmentation index, and cardiac workload. Additionally we will describe pulse wave velocity as a method to measure vascular stiffness and review the impact of increased vascular stiffness as an index of vascular health and as a predictor of adverse cardiovascular outcomes. Furthermore, we will discuss the underlying mechanisms and how these may be modified in order to change the outcomes. A thorough understanding of these concepts is of paramount importance and has therapeutic implications for the increasingly elderly population.

  7. Beyond Critical Congenital Heart Disease: Newborn Screening Using Pulse Oximetry for Neonatal Sepsis and Respiratory Diseases in a Middle-Income Country.

    Science.gov (United States)

    Jawin, Vida; Ang, Hak-Lee; Omar, Asma; Thong, Meow-Keong

    2015-01-01

    Studies on pulse oximetry screening for neonatal sepsis and respiratory disease in a middle-income country are lacking. Newborn screening for critical congenital heart disease (CCHD) using pulse oximetry is an effective and life-saving strategy in developed countries. While most studies have reported false-positive results during CCHD screening, they have not elaborated on the detected disease types. We studied the effectiveness and outcomes of pulse oximetry newborn screening for non-cardiac hypoxemic diseases such as neonatal sepsis, respiratory diseases, and CCHD in a middle-income country. In a pilot study performed at the University Malaya Medical Centre (UMMC), Malaysia, all apparently healthy term newborns, delivered at UMMC were screened pre-discharge using pulse oximetry. Echocardiography was performed for newborns that had positive screening results on two separate occasions, 1-h apart. Newborns with normal echocardiograms were evaluated and treated for other non-cardiac diseases. Fifteen of 5247 term newborns had positive screening results. The median age at screening was 20 h. Thirteen newborns (0.24%) had significant non-cardiac diseases: sepsis (n = 2) and respiratory diseases (n = 11) that required hospitalization and treatment. The remaining two newborns with normal antenatal ultrasonograms had positive screening test and confirmed to have CCHD. Another 18 newborns with negative screening test were later admitted for treatment of sepsis (n = 16) and penumonia (n = 2). All newborns were treated and alive at the end of the study. The sensitivity and specificity of pulse oximetry screening for non-cardiac diseases were 42% and 99.9% respectively, and 100% and 99.7% for CCHD, respectively. Routine pulse oximetry screening test was effective in identifying newborns with CCHD and other hypoxemia illnesses, which may led to potential life-threatening condition. This study showed that the expanded use of pulse oximetry has immediate implications for low

  8. Transference of Fermi Contour Anisotropy to Composite Fermions.

    Science.gov (United States)

    Jo, Insun; Rosales, K A Villegas; Mueed, M A; Pfeiffer, L N; West, K W; Baldwin, K W; Winkler, R; Padmanabhan, Medini; Shayegan, M

    2017-07-07

    There has been a surge of recent interest in the role of anisotropy in interaction-induced phenomena in two-dimensional (2D) charged carrier systems. A fundamental question is how an anisotropy in the energy-band structure of the carriers at zero magnetic field affects the properties of the interacting particles at high fields, in particular of the composite fermions (CFs) and the fractional quantum Hall states (FQHSs). We demonstrate here tunable anisotropy for holes and hole-flux CFs confined to GaAs quantum wells, via applying in situ in-plane strain and measuring their Fermi wave vector anisotropy through commensurability oscillations. For strains on the order of 10^{-4} we observe significant deformations of the shapes of the Fermi contours for both holes and CFs. The measured Fermi contour anisotropy for CFs at high magnetic field (α_{CF}) is less than the anisotropy of their low-field hole (fermion) counterparts (α_{F}), and closely follows the relation α_{CF}=sqrt[α_{F}]. The energy gap measured for the ν=2/3 FQHS, on the other hand, is nearly unaffected by the Fermi contour anisotropy up to α_{F}∼3.3, the highest anisotropy achieved in our experiments.

  9. Pulsed-wave transmitral Doppler do not diagnose moderate acute rejection after heart transplantation

    NARCIS (Netherlands)

    Mannaerts, H. F.; Simoons, M. L.; Balk, A. H.; Tijssen, J.; van der Borden, S. G.; Zondervan, P. E.; Mochtar, B.; Weimar, W.; Roelandt, J. R.

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  10. PULSED-WAVE TRANSMITRAL DOPPLER DO NOT DIAGNOSE MODERATE ACUTE REJECTION AFTER HEART-TRANSPLANTATION

    NARCIS (Netherlands)

    MANNAERTS, HF; SIMOONS, ML; BALK, AH; TIJSSEN, J; VANDERBORDEN, SG; ZONDERVAN, PE; MOCHTAR, B; WEIMAR, W; ROELANDT, [No Value

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  11. Contributions of contour frequency, amplitude, and luminance to the watercolor effect estimated by conjoint measurement.

    Science.gov (United States)

    Gerardin, Peggy; Devinck, Frédéric; Dojat, Michel; Knoblauch, Kenneth

    2014-04-10

    The watercolor effect is a long-range, assimilative, filling-in phenomenon induced by a pair of distant, wavy contours of different chromaticities. Here, we measured joint influences of the contour frequency and amplitude and the luminance of the interior contour on the strength of the effect. Contour pairs, each enclosing a circular region, were presented with two of the dimensions varying independently across trials (luminance/frequency, luminance/amplitude, frequency/amplitude) in a conjoint measurement paradigm (Luce & Tukey, 1964). In each trial, observers judged which of the stimuli evoked the strongest fill-in color. Control stimuli were identical except that the contours were intertwined and generated little filling-in. Perceptual scales were estimated by a maximum likelihood method (Ho, Landy, & Maloney, 2008). An additive model accounted for the joint contributions of any pair of dimensions. As shown previously using difference scaling (Devinck & Knoblauch, 2012), the strength increases with luminance of the interior contour. The strength of the phenomenon was nearly independent of the amplitude of modulation of the contour but increased with its frequency up to an asymptotic level. On average, the strength of the effect was similar along a given dimension regardless of the other dimension with which it was paired, demonstrating consistency of the underlying estimated perceptual scales.

  12. A fully automated contour detection algorithm the preliminary step for scatter and attenuation compensation in SPECT

    International Nuclear Information System (INIS)

    Younes, R.B.; Mas, J.; Bidet, R.

    1988-01-01

    Contour detection is an important step in information extraction from nuclear medicine images. In order to perform accurate quantitative studies in single photon emission computed tomography (SPECT) a new procedure is described which can rapidly derive the best fit contour of an attenuated medium. Some authors evaluate the influence of the detected contour on the reconstructed images with various attenuation correction techniques. Most of the methods are strongly affected by inaccurately detected contours. This approach uses the Compton window to redetermine the convex contour: It seems to be simpler and more practical in clinical SPECT studies. The main advantages of this procedure are the high speed of computation, the accuracy of the contour found and the programme's automation. Results obtained using computer simulated and real phantoms or clinical studies demonstrate the reliability of the present algorithm. (orig.)

  13. Common Visual Preference for Curved Contours in Humans and Great Apes.

    Science.gov (United States)

    Munar, Enric; Gómez-Puerto, Gerardo; Call, Josep; Nadal, Marcos

    2015-01-01

    Among the visual preferences that guide many everyday activities and decisions, from consumer choices to social judgment, preference for curved over sharp-angled contours is commonly thought to have played an adaptive role throughout human evolution, favoring the avoidance of potentially harmful objects. However, because nonhuman primates also exhibit preferences for certain visual qualities, it is conceivable that humans' preference for curved contours is grounded on perceptual and cognitive mechanisms shared with extant nonhuman primate species. Here we aimed to determine whether nonhuman great apes and humans share a visual preference for curved over sharp-angled contours using a 2-alternative forced choice experimental paradigm under comparable conditions. Our results revealed that the human group and the great ape group indeed share a common preference for curved over sharp-angled contours, but that they differ in the manner and magnitude with which this preference is expressed behaviorally. These results suggest that humans' visual preference for curved objects evolved from earlier primate species' visual preferences, and that during this process it became stronger, but also more susceptible to the influence of higher cognitive processes and preference for other visual features.

  14. Luminance contours can gate afterimage colors and "real" colors.

    Science.gov (United States)

    Anstis, Stuart; Vergeer, Mark; Van Lier, Rob

    2012-09-06

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The color of the afterimage depends on two adapting colors, those both inside and outside the test. Here, we further explore this phenomenon and show that the color-contour interactions shown for afterimage colors also occur for "real" colors. We argue that similar mechanisms apply for both types of stimulation.

  15. On a program manifold’s stability of one contour automatic control systems

    Directory of Open Access Journals (Sweden)

    Zumatov S. S.

    2017-12-01

    Full Text Available Methodology of analysis of stability is expounded to the one contour systems automatic control feedback in the presence of non-linearities. The methodology is based on the use of the simplest mathematical models of the nonlinear controllable systems. Stability of program manifolds of one contour automatic control systems is investigated. The sufficient conditions of program manifold’s absolute stability of one contour automatic control systems are obtained. The Hurwitz’s angle of absolute stability was determined. The sufficient conditions of program manifold’s absolute stability of control systems by the course of plane in the mode of autopilot are obtained by means Lyapunov’s second method.

  16. Self-gated fat-suppressed cardiac cine MRI.

    Science.gov (United States)

    Ingle, R Reeve; Santos, Juan M; Overall, William R; McConnell, Michael V; Hu, Bob S; Nishimura, Dwight G

    2015-05-01

    To develop a self-gated alternating repetition time balanced steady-state free precession (ATR-SSFP) pulse sequence for fat-suppressed cardiac cine imaging. Cardiac gating is computed retrospectively using acquired magnetic resonance self-gating data, enabling cine imaging without the need for electrocardiogram (ECG) gating. Modification of the slice-select rephasing gradients of an ATR-SSFP sequence enables the acquisition of a one-dimensional self-gating readout during the unused short repetition time (TR). Self-gating readouts are acquired during every TR of segmented, breath-held cardiac scans. A template-matching algorithm is designed to compute cardiac trigger points from the self-gating signals, and these trigger points are used for retrospective cine reconstruction. The proposed approach is compared with ECG-gated ATR-SSFP and balanced steady-state free precession in 10 volunteers and five patients. The difference of ECG and self-gating trigger times has a variability of 13 ± 11 ms (mean ± SD). Qualitative reviewer scoring and ranking indicate no statistically significant differences (P > 0.05) between self-gated and ECG-gated ATR-SSFP images. Quantitative blood-myocardial border sharpness is not significantly different among self-gated ATR-SSFP ( 0.61±0.15 mm -1), ECG-gated ATR-SSFP ( 0.61±0.15 mm -1), or conventional ECG-gated balanced steady-state free precession cine MRI ( 0.59±0.15 mm -1). The proposed self-gated ATR-SSFP sequence enables fat-suppressed cardiac cine imaging at 1.5 T without the need for ECG gating and without decreasing the imaging efficiency of ATR-SSFP. © 2014 Wiley Periodicals, Inc.

  17. Tonal Language Background and Detecting Pitch Contour in Spoken and Musical Items

    Science.gov (United States)

    Stevens, Catherine J.; Keller, Peter E.; Tyler, Michael D.

    2013-01-01

    An experiment investigated the effect of tonal language background on discrimination of pitch contour in short spoken and musical items. It was hypothesized that extensive exposure to a tonal language attunes perception of pitch contour. Accuracy and reaction times of adult participants from tonal (Thai) and non-tonal (Australian English) language…

  18. SU-C-BRA-03: An Automated and Quick Contour Errordetection for Auto Segmentation in Online Adaptive Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J; Ates, O; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2016-06-15

    Purpose: To develop a tool that can quickly and automatically assess contour quality generated from auto segmentation during online adaptive replanning. Methods: Due to the strict time requirement of online replanning and lack of ‘ground truth’ contours in daily images, our method starts with assessing image registration accuracy focusing on the surface of the organ in question. Several metrics tightly related to registration accuracy including Jacobian maps, contours shell deformation, and voxel-based root mean square (RMS) analysis were computed. To identify correct contours, additional metrics and an adaptive decision tree are introduced. To approve in principle, tests were performed with CT sets, planned and daily CTs acquired using a CT-on-rails during routine CT-guided RT delivery for 20 prostate cancer patients. The contours generated on daily CTs using an auto-segmentation tool (ADMIRE, Elekta, MIM) based on deformable image registration of the planning CT and daily CT were tested. Results: The deformed contours of 20 patients with total of 60 structures were manually checked as baselines. The incorrect rate of total contours is 49%. To evaluate the quality of local deformation, the Jacobian determinant (1.047±0.045) on contours has been analyzed. In an analysis of rectum contour shell deformed, the higher rate (0.41) of error contours detection was obtained compared to 0.32 with manual check. All automated detections took less than 5 seconds. Conclusion: The proposed method can effectively detect contour errors in micro and macro scope by evaluating multiple deformable registration metrics in a parallel computing process. Future work will focus on improving practicability and optimizing calculation algorithms and metric selection.

  19. SU-C-BRA-03: An Automated and Quick Contour Errordetection for Auto Segmentation in Online Adaptive Radiotherapy

    International Nuclear Information System (INIS)

    Zhang, J; Ates, O; Li, X

    2016-01-01

    Purpose: To develop a tool that can quickly and automatically assess contour quality generated from auto segmentation during online adaptive replanning. Methods: Due to the strict time requirement of online replanning and lack of ‘ground truth’ contours in daily images, our method starts with assessing image registration accuracy focusing on the surface of the organ in question. Several metrics tightly related to registration accuracy including Jacobian maps, contours shell deformation, and voxel-based root mean square (RMS) analysis were computed. To identify correct contours, additional metrics and an adaptive decision tree are introduced. To approve in principle, tests were performed with CT sets, planned and daily CTs acquired using a CT-on-rails during routine CT-guided RT delivery for 20 prostate cancer patients. The contours generated on daily CTs using an auto-segmentation tool (ADMIRE, Elekta, MIM) based on deformable image registration of the planning CT and daily CT were tested. Results: The deformed contours of 20 patients with total of 60 structures were manually checked as baselines. The incorrect rate of total contours is 49%. To evaluate the quality of local deformation, the Jacobian determinant (1.047±0.045) on contours has been analyzed. In an analysis of rectum contour shell deformed, the higher rate (0.41) of error contours detection was obtained compared to 0.32 with manual check. All automated detections took less than 5 seconds. Conclusion: The proposed method can effectively detect contour errors in micro and macro scope by evaluating multiple deformable registration metrics in a parallel computing process. Future work will focus on improving practicability and optimizing calculation algorithms and metric selection.

  20. Comparing subjective contours for Kanizsa squares and linear edge alignments ('New York Titanic' figures).

    Science.gov (United States)

    Gillam, Barbara; Marlow, Phillip J

    2014-01-01

    One current view is that subjective contours may involve high-level detection of a salient shape with back propagation to early visual areas where small receptive fields allow for scrutiny of relevant details. This idea applies to Kanizsa-type figures. However, Gillam and Chan (2002 Psychological Science, 13, 279-282) using figures based on Gillam's graphic 'New York Titanic' (Gillam, 1997 Thresholds: Limits of perception. New York: Arts Magazine) showed that strong subjective contours can be seen along the linearly aligned edges of a set of shapes if occlusion cues of 'extrinsic edge' and 'entropy contrast' are strong. Here we compared ratings of the strength of subjective contours along linear alignments with those seen in Kanizsa figures. The strongest subjective contour for a single set of linearly aligned shapes was similar in strength to the edges of a Kanizsa square (controlling for support ratio) despite the lack of a salient region. The addition of a second set of linearly aligned inducers consistent with a common surface increased subjective-contour strength, as did having four rather than two 'pacmen' in the Kanizsa figure, indicating a role for surface support. We argue that linear subjective contours allow for the investigation of certain occlusion cues and the interactions between them that are not easily explored with Kanizsa figures.

  1. Maintaining Contour Trees of Dynamic Terrains

    DEFF Research Database (Denmark)

    Agarwal, Pankaj K.; Arge, Lars; Mølhave, Thomas

    We consider maintaining the contour tree T of a piecewise-linear triangulation M that is the graph of a time varying height function h:R2→R. We carefully describe the combinatorial change in T that happen as h varies over time and how these changes relate to topological changes in M. We present a...

  2. Asymptomatic Changes in Cardiac Function Can Occur in DCIS Patients Following Treatment with HER-2/neu Pulsed Dendritic Cell Vaccines

    Science.gov (United States)

    Bahl, Susan; Roses, Robert; Sharma, Anupama; Koldovsky, Ursula; Xu, Shuwen; Weinstein, Susan; Nisenbaum, Harvey; Fox, Kevin; Pasha, Theresa; Zhang, Paul; Araujo, Louis; Carver, Joseph; Czerniecki, Brian J

    2009-01-01

    Background Targeting HER-2/neu with Trastuzumab has been associated with development of cardiac toxicity. Methods Twenty-seven patients with ductal carcinoma in situ (DCIS) of the breast completed an IRB approved clinical trial of a HER-2/neu targeted dendritic cell based vaccine. Four weekly vaccinations were administered prior to surgical resection. All subjects underwent pre- and post-vaccine cardiac monitoring by MUGA/ECHO scanning allowing for a comparison of cardiac function. Results In 3 of 27 vaccinated patients (11%) transient asymptomatic decrements in ejection fraction of greater than 15% were noted after vaccination. Notably, evidence of circulating anti-HER-2/neu antibody was found prior to vaccination in all three patients, but cardiac toxicity was not noted until induction of cellular mediated immune responses. Conclusions This is the first description of HER-2/neu targeted vaccination associated with an incidence of cardiac changes, and the induction of cellular immune responses combined with antibody may contribute to changes in cardiac function. PMID:19800453

  3. CT urography: segmentation of urinary bladder using CLASS with local contour refinement

    International Nuclear Information System (INIS)

    Cha, Kenny; Hadjiiski, Lubomir; Chan, Heang-Ping; Caoili, Elaine M; Cohan, Richard H; Zhou, Chuan

    2014-01-01

    We are developing a computerized system for bladder segmentation on CT urography (CTU), as a critical component for computer-aided detection of bladder cancer. The presence of regions filled with intravenous contrast and without contrast presents a challenge for bladder segmentation. Previously, we proposed a conjoint level set analysis and segmentation system (CLASS). In case the bladder is partially filled with contrast, CLASS segments the non-contrast (NC) region and the contrast-filled (C) region separately and automatically conjoins the NC and C region contours; however, inaccuracies in the NC and C region contours may cause the conjoint contour to exclude portions of the bladder. To alleviate this problem, we implemented a local contour refinement (LCR) method that exploits model-guided refinement (MGR) and energy-driven wavefront propagation (EDWP). MGR propagates the C region contours if the level set propagation in the C region stops prematurely due to substantial non-uniformity of the contrast. EDWP with regularized energies further propagates the conjoint contours to the correct bladder boundary. EDWP uses changes in energies, smoothness criteria of the contour, and previous slice contour to determine when to stop the propagation, following decision rules derived from training. A data set of 173 cases was collected for this study: 81 cases in the training set (42 lesions, 21 wall thickenings, 18 normal bladders) and 92 cases in the test set (43 lesions, 36 wall thickenings, 13 normal bladders). For all cases, 3D hand segmented contours were obtained as reference standard and used for the evaluation of the computerized segmentation accuracy. For CLASS with LCR, the average volume intersection ratio, average volume error, absolute average volume error, average minimum distance and Jaccard index were 84.2 ± 11.4%, 8.2 ± 17.4%, 13.0 ± 14.1%, 3.5 ± 1.9 mm, 78.8 ± 11.6%, respectively, for the training set and 78.0 ± 14.7%, 16.4 ± 16.9%, 18.2 ± 15

  4. Pelvic Normal Tissue Contouring Guidelines for Radiation Therapy: A Radiation Therapy Oncology Group Consensus Panel Atlas

    Energy Technology Data Exchange (ETDEWEB)

    Gay, Hiram A., E-mail: hgay@radonc.wustl.edu [Washington University School of Medicine, St Louis, MO (United States); Barthold, H. Joseph [Commonwealth Hematology and Oncology, Weymouth, MA (United States); Beth Israel Deaconess Medical Center, Boston, MA (Israel); O' Meara, Elizabeth [Radiation Therapy Oncology Group, Philadelphia, PA (United States); Bosch, Walter R. [Washington University School of Medicine, St Louis, MO (United States); El Naqa, Issam [Department of Radiation Oncology, McGill University Health Center, Montreal, Quebec (Canada); Al-Lozi, Rawan [Washington University School of Medicine, St Louis, MO (United States); Rosenthal, Seth A. [Radiation Oncology Centers, Radiological Associates of Sacramento, Sacramento, CA (United States); Lawton, Colleen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Lee, W. Robert [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Sandler, Howard [Cedars-Sinai Medical Center, Los Angeles, CA (United States); Zietman, Anthony [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Myerson, Robert [Washington University School of Medicine, St Louis, MO (United States); Dawson, Laura A. [Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario (Canada); Willett, Christopher [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Kachnic, Lisa A. [Department of Radiation Oncology, Boston Medical Center, Boston University School of Medicine, Boston, MA (United States); Jhingran, Anuja [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX (United States); Portelance, Lorraine [University of Miami, Miami, FL (United States); Ryu, Janice [Radiation Oncology Centers, Radiological Associates of Sacramento, Sacramento, CA (United States); and others

    2012-07-01

    Purpose: To define a male and female pelvic normal tissue contouring atlas for Radiation Therapy Oncology Group (RTOG) trials. Methods and Materials: One male pelvis computed tomography (CT) data set and one female pelvis CT data set were shared via the Image-Guided Therapy QA Center. A total of 16 radiation oncologists participated. The following organs at risk were contoured in both CT sets: anus, anorectum, rectum (gastrointestinal and genitourinary definitions), bowel NOS (not otherwise specified), small bowel, large bowel, and proximal femurs. The following were contoured in the male set only: bladder, prostate, seminal vesicles, and penile bulb. The following were contoured in the female set only: uterus, cervix, and ovaries. A computer program used the binomial distribution to generate 95% group consensus contours. These contours and definitions were then reviewed by the group and modified. Results: The panel achieved consensus definitions for pelvic normal tissue contouring in RTOG trials with these standardized names: Rectum, AnoRectum, SmallBowel, Colon, BowelBag, Bladder, UteroCervix, Adnexa{sub R}, Adnexa{sub L}, Prostate, SeminalVesc, PenileBulb, Femur{sub R}, and Femur{sub L}. Two additional normal structures whose purpose is to serve as targets in anal and rectal cancer were defined: AnoRectumSig and Mesorectum. Detailed target volume contouring guidelines and images are discussed. Conclusions: Consensus guidelines for pelvic normal tissue contouring were reached and are available as a CT image atlas on the RTOG Web site. This will allow uniformity in defining normal tissues for clinical trials delivering pelvic radiation and will facilitate future normal tissue complication research.

  5. Epinephrine in Out-of-hospital Cardiac Arrest: Helpful or Harmful?

    Science.gov (United States)

    Shao, Huan; Li, Chun-Sheng

    2017-09-05

    Epinephrine is the primary drug administered during cardiopulmonary resuscitation (CPR) to reverse cardiac arrest. The evidence for the use of adrenaline in out-of-hospital cardiac arrest (OHCA) and in-hospital resuscitation is inconclusive. We conducted a systematic review on the clinical efficacy of adrenaline in adult OHCA patients to evaluate whether epinephrine provides any overall benefit for patients. The EMBASE and PubMed databases were searched with the key words "epinephrine," "cardiac arrest," and variations of these terms. Data from clinical randomized trials, meta-analyses, guidelines, and recent reviews were selected for review. Sudden cardiac arrest causes 544,000 deaths in China each year, with survival occurring in CPR. There is currently insufficient evidence to support or reject epinephrine administration during resuscitation. We believe that epinephrine may have a role in resuscitation, as administration of epinephrine during CPR increases the probability of restoring cardiac activity with pulses, which is an essential intermediate step toward long-term survival. The administration of adrenaline was associated with improved short-term survival (ROSC). However, it appears that the use of adrenaline is associated with no benefit on survival to hospital discharge or survival with favorable neurological outcome after OHCA, and it may have a harmful effect. Larger placebo-controlled, double-blind, randomized control trials are required to definitively establish the effect of epinephrine.

  6. A Social Evaluation of Perception on Body Contouring Surgery by Turkish Male Aesthetic Surgery Patients.

    Science.gov (United States)

    Ozel, Bora; Sezgin, Billur; Guney, Kirdar; Latifoglu, Osman; Celebi, Cemallettin

    2015-02-01

    Although aesthetic procedures are known to have a higher impact on women, men are becoming more inclined toward such procedures since the last decade. To determine the reason behind the increase in demand for male aesthetic procedures and to learn about the expectations and inquietude related to body contouring surgery, a prospective questionnaire study was conducted on 200 Turkish males from January 1, 2011-May 31, 2012. Demographic information, previous aesthetic procedures and thoughts on body contouring procedures with given reasons were questioned. The results of the study showed that 53 % of all participants considered undergoing body contouring surgery with the given reason that they believed their current body structure required it. For those who did not consider contouring operations, 92.5 % said they felt that they did not need such a procedure. The results of the statistical analysis showed that BMI was a significant factor in the decision making process for wanting to undergo body contouring procedures. The results of the study showed that men's consideration for aesthetic operations depends mainly on necessity and that the most considered region was the abdominal zone in regard to contouring. We can conclude that men are becoming more interested in body contouring operations and therefore different surgical procedures should be refined and re-defined according to the expectations of this new patient group.

  7. Evaluation of the optical conductivity tensor in terms of contour integrations

    OpenAIRE

    Szunyogh, Laszlo; Weinberger, Peter

    2000-01-01

    For the case of finite life-time broadening the standard Kubo-formula for the optical conductivity tensor is rederived in terms of Green's functions by using contour integrations, whereby finite temperatures are accounted for by using the Fermi-Dirac distribution function. For zero life-time broadening, the present formalism is related to expressions well-known in the literature. Numerical aspects of how to calculate the corresponding contour integrals are also outlined.

  8. Ship-borne contour integration for flux determination

    NARCIS (Netherlands)

    Groeskamp, S.; Maas, L.R.M.

    2012-01-01

    The consumption of nutrients by mussel beds can be monitored by measuring the net nutrient flux across a circumscribing vertical surface. Measuring this nutrient flux not only requires resolving the spatial (and temporal) distribution of nutrients at the bounding contour, but also an ability to

  9. Feasibility of geometrical verification of patient set-up using body contours and computed tomography data

    International Nuclear Information System (INIS)

    Ploeger, Lennert S.; Betgen, Anja; Gilhuijs, Kenneth G.A.; Herk, Marcel van

    2003-01-01

    Background and purpose: Body contours can potentially be used for patient set-up verification in external-beam radiotherapy and might enable more accurate set-up of patients prior to irradiation. The aim of this study is to test the feasibility of patient set-up verification using a body contour scanner. Material and methods: Body contour scans of 33 lung cancer and 21 head-and-neck cancer patients were acquired on a simulator. We assume that this dataset is representative for the patient set-up on an accelerator. Shortly before acquisition of the body contour scan, a pair of orthogonal simulator images was taken as a reference. Both the body contour scan and the simulator images were matched in 3D to the planning computed tomography scan. Movement of skin with respect to bone was quantified based on an analysis of variance method. Results: Set-up errors determined with body-contours agreed reasonably well with those determined with simulator images. For the lung cancer patients, the average set-up errors (mm)±1 standard deviation (SD) for the left-right, cranio-caudal and anterior-posterior directions were 1.2±2.9, -0.8±5.0 and -2.3±3.1 using body contours, compared to -0.8±3.2, -1.0±4.1 and -1.2±2.4 using simulator images. For the head-and-neck cancer patients, the set-up errors were 0.5±1.8, 0.5±2.7 and -2.2±1.8 using body contours compared to -0.4±1.2, 0.1±2.1, -0.1±1.8 using simulator images. The SD of the set-up errors obtained from analysis of the body contours were not significantly different from those obtained from analysis of the simulator images. Movement of the skin with respect to bone (1 SD) was estimated at 2.3 mm for lung cancer patients and 1.7 mm for head-and-neck cancer patients. Conclusion: Measurement of patient set-up using a body-contouring device is possible. The accuracy, however, is limited by the movement of the skin with respect to the bone. In situations where the error in the patient set-up is relatively large, it is

  10. Measuring multiple residual-stress components using the contour method and multiple cuts

    Energy Technology Data Exchange (ETDEWEB)

    Prime, Michael B [Los Alamos National Laboratory; Swenson, Hunter [Los Alamos National Laboratory; Pagliaro, Pierluigi [U. PALERMO; Zuccarello, Bernardo [U. PALERMO

    2009-01-01

    The conventional contour method determines one component of stress over the cross section of a part. The part is cut into two, the contour of the exposed surface is measured, and Bueckner's superposition principle is analytically applied to calculate stresses. In this paper, the contour method is extended to the measurement of multiple stress components by making multiple cuts with subsequent applications of superposition. The theory and limitations are described. The theory is experimentally tested on a 316L stainless steel disk with residual stresses induced by plastically indenting the central portion of the disk. The stress results are validated against independent measurements using neutron diffraction. The theory has implications beyond just multiple cuts. The contour method measurements and calculations for the first cut reveal how the residual stresses have changed throughout the part. Subsequent measurements of partially relaxed stresses by other techniques, such as laboratory x-rays, hole drilling, or neutron or synchrotron diffraction, can be superimposed back to the original state of the body.

  11. TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H; Tan, J; Kavanaugh, J; Dolly, S; Gay, H; Thorstad, W; Anastasio, M; Altman, M; Mutic, S; Li, H [Washington University School of Medicine, Saint Louis, MO (United States)

    2014-06-15

    Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding

  12. Development and evaluation of a new contoured cushion system with an optimized normalization algorithm.

    Science.gov (United States)

    Li, Sujiao; Zhang, Zhengxiang; Wang, Jue

    2014-01-01

    Prevention of pressure sores remains a significant problem confronting spinal cord injury patients and the elderly with limited mobility. One vital aspect of this subject concerns the development of cushions to decrease pressure ulcers for seated patients, particularly those bound by wheelchairs. Here, we present a novel cushion system that employs interface pressure distribution between the cushion and the buttocks to design custom contoured foam cushion. An optimized normalization algorithm was proposed, with which interface pressure distribution was transformed into the carving depth of foam cushions according to the biomechanical characteristics of the foam. The shape and pressure-relief performance of the custom contoured foam cushions was investigated. The outcomes showed that the contoured shape of personalized cushion matched the buttock contour very well. Moreover, the custom contoured cushion could alleviate pressure under buttocks and increase subjective comfort and stability significantly. Furthermore, the fabricating method not only decreased the unit production cost but also simplified the procedure for manufacturing. All in all, this prototype seat cushion would be an effective and economical way to prevent pressure ulcers.

  13. Analysis of irradiance losses on a soiled photovoltaic panel using contours

    International Nuclear Information System (INIS)

    Pulipaka, Subrahmanyam; Kumar, Rajneesh

    2016-01-01

    Highlights: • An irradiance loss factor to quantify relationship between irradiance, tilt angle and power of soiled panel is proposed. • Artificial soiling experiment and Sieve analysis are performed to obtain data for developing contours. • Contour analysis is used to observe the deviation in power of a soiled panel from clean panel. • A correction factor to calculate power of a soiled panel is proposed. • The correction factor is expressed in terms of soil particle size composition present on panel. - Abstract: This paper introduces an irradiance loss factor that quantifies the relationship between irradiance, tilt angle and power output of a soiled panel with the soil particle size composition. Artificial soiling experiments were performed using four soil samples at irradiance levels between 200 and 1200 W/m"2 at 18 tilt angles. Biharmonic interpolation was used to develop power contours in terms of irradiance and tilt angle from experimentally obtained data. These contours were compared with ideal ones of a clean panel to observe deviation in the nature of contours for a soiled panel. A correction factor in terms of particle size composition (as a coefficient to tilt angle) was proposed to calculate power output of a tilted soiled panel. The angular loss on a panel with soil sample containing 150 μm particle size in abundance was observed to be 22% and for sample containing 75 μm particles in majority, the loss is 24%. Presence of 300 μm particle size in abundance causes a 23.7% loss, while 52% angular loss was observed for soil with highest composition of less than 75 μm particle size.

  14. AN IMPROVED SNAKE MODEL FOR REFINEMENT OF LIDAR-DERIVED BUILDING ROOF CONTOURS USING AERIAL IMAGES

    Directory of Open Access Journals (Sweden)

    Q. Chen

    2016-06-01

    Full Text Available Building roof contours are considered as very important geometric data, which have been widely applied in many fields, including but not limited to urban planning, land investigation, change detection and military reconnaissance. Currently, the demand on building contours at a finer scale (especially in urban areas has been raised in a growing number of studies such as urban environment quality assessment, urban sprawl monitoring and urban air pollution modelling. LiDAR is known as an effective means of acquiring 3D roof points with high elevation accuracy. However, the precision of the building contour obtained from LiDAR data is restricted by its relatively low scanning resolution. With the use of the texture information from high-resolution imagery, the precision can be improved. In this study, an improved snake model is proposed to refine the initial building contours extracted from LiDAR. First, an improved snake model is constructed with the constraints of the deviation angle, image gradient, and area. Then, the nodes of the contour are moved in a certain range to find the best optimized result using greedy algorithm. Considering both precision and efficiency, the candidate shift positions of the contour nodes are constrained, and the searching strategy for the candidate nodes is explicitly designed. The experiments on three datasets indicate that the proposed method for building contour refinement is effective and feasible. The average quality index is improved from 91.66% to 93.34%. The statistics of the evaluation results for every single building demonstrated that 77.0% of the total number of contours is updated with higher quality index.

  15. Extension of Fourier methods to the calculation of effective depths in heterogeneous media of arbitrary contour

    International Nuclear Information System (INIS)

    Starkschall, G.

    1986-01-01

    The description of patient contours and internal structures by means of truncated Fourier series can be extended to continuous contours of arbitrary shape and location by expressing the x and z Cartesian coordinates of the contour as independent Fourier series in a parameter t. An analytic equation for the intersection of the contour and a ray line is then written as an equation in the parameter t. The equation can be solved using numerical methods yielding the Cartesian coordinates of the intersection point directly

  16. Variations in the Contouring of Organs at Risk: Test Case From a Patient With Oropharyngeal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E., E-mail: alpha@canislupusllc.com [Canis Lupus LLC, Merrimac, WI (United States); Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin, Madison, WI (United States); Robinson, Greg [Radiation Oncology Resources, Goshen, IN (United States); Wheeler, James [Department of Radiation Oncology, Goshen Health System Goshen, IN (United States)

    2012-01-01

    Purpose: Anatomy contouring is critical in radiation therapy. Inaccuracy and variation in defining critical volumes will affect everything downstream: treatment planning, dose-volume histogram analysis, and contour-based visual guidance used in image-guided radiation therapy. This study quantified: (1) variation in the contouring of organs at risk (OAR) in a clinical test case and (2) corresponding effects on dosimetric metrics of highly conformal plans. Methods and Materials: A common CT data set with predefined targets from a patient with oropharyngeal cancer was provided to a population of clinics, which were asked to (1) contour OARs and (2) design an intensity-modulated radiation therapy plan. Thirty-two acceptable plans were submitted as DICOM RT data sets, each generated by a different clinical team. Using those data sets, we quantified: (1) the OAR contouring variation and (2) the impact this variation has on dosimetric metrics. New technologies were employed, including a software tool to quantify three-dimensional structure comparisons. Results: There was significant interclinician variation in OAR contouring. The degree of variation is organ-dependent. We found substantial dose differences resulting strictly from contouring variation (differences ranging from -289% to 56% for mean OAR dose; -22% to 35% for maximum dose). However, there appears to be a threshold in the OAR comparison metric beyond which the dose differences stabilize. Conclusions: The effects of interclinician variation in contouring organs-at-risk in the head and neck can be large and are organ-specific. Physicians need to be aware of the effect that variation in OAR contouring can play on the final treatment plan and not restrict their focus only to the target volumes.

  17. On the Relationship between Variational Level Set-Based and SOM-Based Active Contours

    Science.gov (United States)

    Abdelsamea, Mohammed M.; Gnecco, Giorgio; Gaber, Mohamed Medhat; Elyan, Eyad

    2015-01-01

    Most Active Contour Models (ACMs) deal with the image segmentation problem as a functional optimization problem, as they work on dividing an image into several regions by optimizing a suitable functional. Among ACMs, variational level set methods have been used to build an active contour with the aim of modeling arbitrarily complex shapes. Moreover, they can handle also topological changes of the contours. Self-Organizing Maps (SOMs) have attracted the attention of many computer vision scientists, particularly in modeling an active contour based on the idea of utilizing the prototypes (weights) of a SOM to control the evolution of the contour. SOM-based models have been proposed in general with the aim of exploiting the specific ability of SOMs to learn the edge-map information via their topology preservation property and overcoming some drawbacks of other ACMs, such as trapping into local minima of the image energy functional to be minimized in such models. In this survey, we illustrate the main concepts of variational level set-based ACMs, SOM-based ACMs, and their relationship and review in a comprehensive fashion the development of their state-of-the-art models from a machine learning perspective, with a focus on their strengths and weaknesses. PMID:25960736

  18. A 3-Step Algorithm Using Region-Based Active Contours for Video Objects Detection

    Directory of Open Access Journals (Sweden)

    Stéphanie Jehan-Besson

    2002-06-01

    Full Text Available We propose a 3-step algorithm for the automatic detection of moving objects in video sequences using region-based active contours. First, we introduce a very full general framework for region-based active contours with a new Eulerian method to compute the evolution equation of the active contour from a criterion including both region-based and boundary-based terms. This framework can be easily adapted to various applications, thanks to the introduction of functions named descriptors of the different regions. With this new Eulerian method based on shape optimization principles, we can easily take into account the case of descriptors depending upon features globally attached to the regions. Second, we propose a 3-step algorithm for detection of moving objects, with a static or a mobile camera, using region-based active contours. The basic idea is to hierarchically associate temporal and spatial information. The active contour evolves with successively three sets of descriptors: a temporal one, and then two spatial ones. The third spatial descriptor takes advantage of the segmentation of the image in intensity homogeneous regions. User interaction is reduced to the choice of a few parameters at the beginning of the process. Some experimental results are supplied.

  19. Sound wave contours around wind turbine arrays

    International Nuclear Information System (INIS)

    Van Beek, A.; Van Blokland, G.J.

    1993-02-01

    Noise pollution is an important factor in selecting suitable sites for wind turbines in order to realize 1000 MW of wind power as planned by the Dutch government for the year 2000. Therefore an accurate assessment of wind turbine noise is important. The amount of noise pollution from a wind turbine depends on the wind conditions. An existing standard method to assess wind turbine noise is supplemented and adjusted. In the first part of the investigation the method was developed and applied for a solitary sound source. In the second part attention is paid to the use of the method for wind turbine arrays. It appears that the adjusted method results in a shift of the contours of the permitted noise level. In general the contours are 15-25% closer to the wind farm, which means that the minimal permitted distance between houses and wind turbine arrays can be reduced. 14 figs., 1 tab., 4 appendices, 7 refs

  20. Non-contact tonometry synchronized with cardiac rhythm and its relationship with blood pressure.

    Science.gov (United States)

    Queirós, A; González-Méijome, J M; Fernandes, P; Jorge, J; Almeida, J B; Parafita, M A

    2006-07-01

    The main objectives of this study were to determine the differences between non-synchronized intraocular pressure (IOP_N) and intraocular pressure readings synchronized with cardiac pulse and try to determine if these parameters are related to blood pressure values. One hundred and sixty-five right eyes from 165 volunteers (107 females, 58 males) aged from 19 to 73 years (mean +/- S.D., 29.93 +/- 11.17) were examined with the Nidek NT-4000, a new non-contact tonometer that allows the measurement of IOP synchronized with the cardiac rhythm. IOP measurements in the four different modes of synchronization were taken in a randomized order. Three measures of each parameter were taken and then averaged. The blood pressure was determined three times with a portable manometer and mean values of systolic and diastolic pressure and the pulse rate were computed. Mean arterial pressure (MAP) was determined as being 1/3 of systolic plus 2/3 of diastolic blood pressure. The mean +/- S.D. values for the standard intraocular pressure (IOP_N: 14.76 +/- 2.86), intraocular pressure in the systolic instant or peak (IOP_P: 14.99 +/- 2.85), intraocular pressure in the middle instant between heartbeats or middle (IOP_M: 14.68 +/- 2.76), and intraocular pressure in the diastolic instant or bottom (IOP_B: 13.86 +/- 2.61) were obtained. The IOP_P was higher than the remaining values. A significant difference in mean IOP existed between IOP_B and the remaining modes of measuring (p non-synchronized and the remaining synchronized parameters in a significant way. Other than a weak association with MAP, no significant correlation between IOP and BP was found. The measurements of IOP readings for the three modes are consistent with timings during the cardiac cycle and IOP pulse cycle.

  1. Top-Down Modulation on the Perception and Categorization of Identical Pitch Contours in Speech and Music

    Directory of Open Access Journals (Sweden)

    Joey L. Weidema

    2016-06-01

    Full Text Available Whether pitch in language and music is governed by domain-specific or domain-general cognitive mechanisms is contentiously debated. The aim of the present study was to investigate whether mechanisms governing pitch contour perception operate differently when pitch information is interpreted as either speech or music. By modulating listening mode, this study aspired to demonstrate that pitch contour perception relies on domain-specific cognitive mechanisms, which are regulated by top-down influences from language and music. Three groups of participants (Mandarin speakers, Dutch speaking non-musicians, and Dutch musicians were exposed to identical pitch contours, and tested on their ability to identify these contours in a language and musical context. Stimuli consisted of disyllabic words spoken in Mandarin, and melodic tonal analogues, embedded in a linguistic and melodic carrier phrase, respectively. Participants classified identical pitch contours as significantly different depending on listening mode. Top-down influences from language appeared to alter the perception of pitch contour in speakers of Mandarin. This was not the case for non-musician speakers of Dutch. Moreover, this effect was lacking in Dutch speaking musicians. The classification patterns of pitch contours in language and music seem to suggest that domain-specific categorization is modulated by top-down influences from language and music.

  2. An automated approach for segmentation of intravascular ultrasound images based on parametric active contour models

    International Nuclear Information System (INIS)

    Vard, Alireza; Jamshidi, Kamal; Movahhedinia, Naser

    2012-01-01

    This paper presents a fully automated approach to detect the intima and media-adventitia borders in intravascular ultrasound images based on parametric active contour models. To detect the intima border, we compute a new image feature applying a combination of short-term autocorrelations calculated for the contour pixels. These feature values are employed to define an energy function of the active contour called normalized cumulative short-term autocorrelation. Exploiting this energy function, the intima border is separated accurately from the blood region contaminated by high speckle noise. To extract media-adventitia boundary, we define a new form of energy function based on edge, texture and spring forces for the active contour. Utilizing this active contour, the media-adventitia border is identified correctly even in presence of branch openings and calcifications. Experimental results indicate accuracy of the proposed methods. In addition, statistical analysis demonstrates high conformity between manual tracing and the results obtained by the proposed approaches.

  3. Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Hsin-Chen; Tan, Jun; Dolly, Steven; Kavanaugh, James; Harold Li, H.; Altman, Michael; Gay, Hiram; Thorstad, Wade L.; Mutic, Sasa; Li, Hua, E-mail: huli@radonc.wustl.edu [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Anastasio, Mark A. [Department of Biomedical Engineering, Washington University, St. Louis, Missouri 63110 (United States); Low, Daniel A. [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California 90095 (United States)

    2015-02-15

    Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets

  4. Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

    International Nuclear Information System (INIS)

    Chen, Hsin-Chen; Tan, Jun; Dolly, Steven; Kavanaugh, James; Harold Li, H.; Altman, Michael; Gay, Hiram; Thorstad, Wade L.; Mutic, Sasa; Li, Hua; Anastasio, Mark A.; Low, Daniel A.

    2015-01-01

    Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets

  5. Features of the non-contact carotid pressure waveform: Cardiac and vascular dynamics during rebreathing

    Science.gov (United States)

    Casaccia, S.; Sirevaag, E. J.; Richter, E. J.; O'Sullivan, J. A.; Scalise, L.; Rohrbaugh, J. W.

    2016-10-01

    This report amplifies and extends prior descriptions of the use of laser Doppler vibrometry (LDV) as a method for assessing cardiovascular activity, on a non-contact basis. A rebreathing task (n = 35 healthy individuals) was used to elicit multiple effects associated with changes in autonomic drive as well as blood gases including hypercapnia. The LDV pulse was obtained from two sites overlying the carotid artery, separated by 40 mm. A robust pulse signal was obtained from both sites, in accord with the well-described changes in carotid diameter over the blood pressure cycle. Emphasis was placed on extracting timing measures from the LDV pulse, which could serve as surrogate measures of pulse wave velocity (PWV) and the associated arterial stiffness. For validation purposes, a standard measure of pulse transit time (PTT) to the radial artery was obtained using a tonometric sensor. Two key measures of timing were extracted from the LDV pulse. One involved the transit time along the 40 mm distance separating the two LDV measurement sites. A second measure involved the timing of a late feature of the LDV pulse contour, which was interpreted as reflection wave latency and thus a measure of round-trip travel time. Both LDV measures agreed with the conventional PTT measure, in disclosing increased PWV during periods of active rebreathing. These results thus provide additional evidence that measures based on the non-contact LDV technique might provide surrogate measures for those obtained using conventional, more obtrusive assessment methods that require attached sensors.

  6. Atlas-Based Segmentation Improves Consistency and Decreases Time Required for Contouring Postoperative Endometrial Cancer Nodal Volumes

    International Nuclear Information System (INIS)

    Young, Amy V.; Wortham, Angela; Wernick, Iddo; Evans, Andrew; Ennis, Ronald D.

    2011-01-01

    Purpose: Accurate target delineation of the nodal volumes is essential for three-dimensional conformal and intensity-modulated radiotherapy planning for endometrial cancer adjuvant therapy. We hypothesized that atlas-based segmentation ('autocontouring') would lead to time savings and more consistent contours among physicians. Methods and Materials: A reference anatomy atlas was constructed using the data from 15 postoperative endometrial cancer patients by contouring the pelvic nodal clinical target volume on the simulation computed tomography scan according to the Radiation Therapy Oncology Group 0418 trial using commercially available software. On the simulation computed tomography scans from 10 additional endometrial cancer patients, the nodal clinical target volume autocontours were generated. Three radiation oncologists corrected the autocontours and delineated the manual nodal contours under timed conditions while unaware of the other contours. The time difference was determined, and the overlap of the contours was calculated using Dice's coefficient. Results: For all physicians, manual contouring of the pelvic nodal target volumes and editing the autocontours required a mean ± standard deviation of 32 ± 9 vs. 23 ± 7 minutes, respectively (p = .000001), a 26% time savings. For each physician, the time required to delineate the manual contours vs. correcting the autocontours was 30 ± 3 vs. 21 ± 5 min (p = .003), 39 ± 12 vs. 30 ± 5 min (p = .055), and 29 ± 5 vs. 20 ± 5 min (p = .0002). The mean overlap increased from manual contouring (0.77) to correcting the autocontours (0.79; p = .038). Conclusion: The results of our study have shown that autocontouring leads to increased consistency and time savings when contouring the nodal target volumes for adjuvant treatment of endometrial cancer, although the autocontours still required careful editing to ensure that the lymph nodes at risk of recurrence are properly included in the target volume.

  7. An improved active contour model for glacial lake extraction

    Science.gov (United States)

    Zhao, H.; Chen, F.; Zhang, M.

    2017-12-01

    Active contour model is a widely used method in visual tracking and image segmentation. Under the driven of objective function, the initial curve defined in active contour model will evolve to a stable condition - a desired result in given image. As a typical region-based active contour model, C-V model has a good effect on weak boundaries detection and anti noise ability which shows great potential in glacial lake extraction. Glacial lake is a sensitive indicator for reflecting global climate change, therefore accurate delineate glacial lake boundaries is essential to evaluate hydrologic environment and living environment. However, the current method in glacial lake extraction mainly contains water index method and recognition classification method are diffcult to directly applied in large scale glacial lake extraction due to the diversity of glacial lakes and masses impacted factors in the image, such as image noise, shadows, snow and ice, etc. Regarding the abovementioned advantanges of C-V model and diffcults in glacial lake extraction, we introduce the signed pressure force function to improve the C-V model for adapting to processing of glacial lake extraction. To inspect the effect of glacial lake extraction results, three typical glacial lake development sites were selected, include Altai mountains, Centre Himalayas, South-eastern Tibet, and Landsat8 OLI imagery was conducted as experiment data source, Google earth imagery as reference data for varifying the results. The experiment consequence suggests that improved active contour model we proposed can effectively discriminate the glacial lakes from complex backgound with a higher Kappa Coefficient - 0.895, especially in some small glacial lakes which belongs to weak information in the image. Our finding provide a new approach to improved accuracy under the condition of large proportion of small glacial lakes and the possibility for automated glacial lake mapping in large-scale area.

  8. The relative pose estimation of aircraft based on contour model

    Science.gov (United States)

    Fu, Tai; Sun, Xiangyi

    2017-02-01

    This paper proposes a relative pose estimation approach based on object contour model. The first step is to obtain a two-dimensional (2D) projection of three-dimensional (3D)-model-based target, which will be divided into 40 forms by clustering and LDA analysis. Then we proceed by extracting the target contour in each image and computing their Pseudo-Zernike Moments (PZM), thus a model library is constructed in an offline mode. Next, we spot a projection contour that resembles the target silhouette most in the present image from the model library with reference of PZM; then similarity transformation parameters are generated as the shape context is applied to match the silhouette sampling location, from which the identification parameters of target can be further derived. Identification parameters are converted to relative pose parameters, in the premise that these values are the initial result calculated via iterative refinement algorithm, as the relative pose parameter is in the neighborhood of actual ones. At last, Distance Image Iterative Least Squares (DI-ILS) is employed to acquire the ultimate relative pose parameters.

  9. Determination of patients contour for using in radiotherapy planning, by microcomputer

    International Nuclear Information System (INIS)

    Elbern, A.W.; Souto, S.L.L.

    1987-01-01

    This work describes a system for measuring the contour of patients, based on a mechanical device which, during the movement of its tip over the patient's contour, changes the resistence of three potenciometers while the device change its angles. The resistence variation, produces voltage changes, which are digitalized by an analog to digital converter in a microcomputer. The mathematical routines for processing the acquired data, and the obtained results, are discussed in this paper. (author) [pt

  10. Determination of patient's contour for use in radiotherapeutic planning by microcomputer

    International Nuclear Information System (INIS)

    Elbern, A.W.; Souto, S.L.L.

    1987-01-01

    A system for measuring the contour of patients based on a mechanical device, is described. During the movement of the device's tip, over the patient's contour, changes in the resistence of three potenciometers are reported, and the device changes its angles. Voltage changes produced by resistence variation, are digitalized by an analog to digital converter in a micro-computer. The mathematical routines for processing the acquired data, and the obtained results are discussed. (M.A.C.) [pt

  11. SU-F-J-72: A Clinical Usable Integrated Contouring Quality Evaluation Software for Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, S; Dolly, S; Cai, B; Mutic, S; Li, H [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: To introduce the Auto Contour Evaluation (ACE) software, which is the clinical usable, user friendly, efficient and all-in-one toolbox for automatically identify common contouring errors in radiotherapy treatment planning using supervised machine learning techniques. Methods: ACE is developed with C# using Microsoft .Net framework and Windows Presentation Foundation (WPF) for elegant GUI design and smooth GUI transition animations through the integration of graphics engines and high dots per inch (DPI) settings on modern high resolution monitors. The industrial standard software design pattern, Model-View-ViewModel (MVVM) pattern, is chosen to be the major architecture of ACE for neat coding structure, deep modularization, easy maintainability and seamless communication with other clinical software. ACE consists of 1) a patient data importing module integrated with clinical patient database server, 2) a 2D DICOM image and RT structure simultaneously displaying module, 3) a 3D RT structure visualization module using Visualization Toolkit or VTK library and 4) a contour evaluation module using supervised pattern recognition algorithms to detect contouring errors and display detection results. ACE relies on supervised learning algorithms to handle all image processing and data processing jobs. Implementations of related algorithms are powered by Accord.Net scientific computing library for better efficiency and effectiveness. Results: ACE can take patient’s CT images and RT structures from commercial treatment planning software via direct user input or from patients’ database. All functionalities including 2D and 3D image visualization and RT contours error detection have been demonstrated with real clinical patient cases. Conclusion: ACE implements supervised learning algorithms and combines image processing and graphical visualization modules for RT contours verification. ACE has great potential for automated radiotherapy contouring quality verification

  12. SU-F-J-72: A Clinical Usable Integrated Contouring Quality Evaluation Software for Radiotherapy

    International Nuclear Information System (INIS)

    Jiang, S; Dolly, S; Cai, B; Mutic, S; Li, H

    2016-01-01

    Purpose: To introduce the Auto Contour Evaluation (ACE) software, which is the clinical usable, user friendly, efficient and all-in-one toolbox for automatically identify common contouring errors in radiotherapy treatment planning using supervised machine learning techniques. Methods: ACE is developed with C# using Microsoft .Net framework and Windows Presentation Foundation (WPF) for elegant GUI design and smooth GUI transition animations through the integration of graphics engines and high dots per inch (DPI) settings on modern high resolution monitors. The industrial standard software design pattern, Model-View-ViewModel (MVVM) pattern, is chosen to be the major architecture of ACE for neat coding structure, deep modularization, easy maintainability and seamless communication with other clinical software. ACE consists of 1) a patient data importing module integrated with clinical patient database server, 2) a 2D DICOM image and RT structure simultaneously displaying module, 3) a 3D RT structure visualization module using Visualization Toolkit or VTK library and 4) a contour evaluation module using supervised pattern recognition algorithms to detect contouring errors and display detection results. ACE relies on supervised learning algorithms to handle all image processing and data processing jobs. Implementations of related algorithms are powered by Accord.Net scientific computing library for better efficiency and effectiveness. Results: ACE can take patient’s CT images and RT structures from commercial treatment planning software via direct user input or from patients’ database. All functionalities including 2D and 3D image visualization and RT contours error detection have been demonstrated with real clinical patient cases. Conclusion: ACE implements supervised learning algorithms and combines image processing and graphical visualization modules for RT contours verification. ACE has great potential for automated radiotherapy contouring quality verification

  13. Fourier Descriptor Analysis and Unification of Voice Range Profile Contours: Method and Applications

    Science.gov (United States)

    Pabon, Peter; Ternstrom, Sten; Lamarche, Anick

    2011-01-01

    Purpose: To describe a method for unified description, statistical modeling, and comparison of voice range profile (VRP) contours, even from diverse sources. Method: A morphologic modeling technique, which is based on Fourier descriptors (FDs), is applied to the VRP contour. The technique, which essentially involves resampling of the curve of the…

  14. Usefulness of emergency ultrasound in nontraumatic cardiac arrest.

    Science.gov (United States)

    Volpicelli, Giovanni

    2011-02-01

    Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Design optimization of highly asymmetrical layouts by 2D contour metrology

    Science.gov (United States)

    Hu, C. M.; Lo, Fred; Yang, Elvis; Yang, T. H.; Chen, K. C.

    2018-03-01

    As design pitch shrinks to the resolution limit of up-to-date optical lithography technology, the Critical Dimension (CD) variation tolerance has been dramatically decreased for ensuring the functionality of device. One of critical challenges associates with the narrower CD tolerance for whole chip area is the proximity effect control on asymmetrical layout environments. To fulfill the tight CD control of complex features, the Critical Dimension Scanning Electron Microscope (CD-SEM) based measurement results for qualifying process window and establishing the Optical Proximity Correction (OPC) model become insufficient, thus 2D contour extraction technique [1-5] has been an increasingly important approach for complementing the insufficiencies of traditional CD measurement algorithm. To alleviate the long cycle time and high cost penalties for product verification, manufacturing requirements are better to be well handled at design stage to improve the quality and yield of ICs. In this work, in-house 2D contour extraction platform was established for layout design optimization of 39nm half-pitch Self-Aligned Double Patterning (SADP) process layer. Combining with the adoption of Process Variation Band Index (PVBI), the contour extraction platform enables layout optimization speedup as comparing to traditional methods. The capabilities of identifying and handling lithography hotspots in complex layout environments of 2D contour extraction platform allow process window aware layout optimization to meet the manufacturing requirements.

  16. Rapid Automated Target Segmentation and Tracking on 4D Data without Initial Contours

    International Nuclear Information System (INIS)

    Chebrolu, V.V.; Chebrolu, V.V.; Saenz, D.; Tewatia, D.; Paliwal, B.R.; Chebrolu, V.V.; Saenz, D.; Paliwal, B.R.; Sethares, W.A.; Cannon, G.

    2014-01-01

    To achieve rapid automated delineation of gross target volume (GTV) and to quantify changes in volume/position of the target for radiotherapy planning using four-dimensional (4D) CT. Methods and Materials. Novel morphological processing and successive localization (MPSL) algorithms were designed and implemented for achieving auto segmentation. Contours automatically generated using MPSL method were compared with contours generated using state-of-the-art deformable registration methods (using Elastix © and MIMV ista software). Metrics such as the Dice similarity coefficient, sensitivity, and positive predictive value (PPV) were analyzed. The target motion tracked using the centroid of the GTV estimated using MPSL method was compared with motion tracked using deformable registration methods. Results. MPSL algorithm segmented the GTV in 4DCT images in 27.0 ±11.1 seconds per phase ( 512 ×512 resolution) as compared to 142.3±11.3 seconds per phase for deformable registration based methods in 9 cases. Dice coefficients between MPSL generated GTV contours and manual contours (considered as ground-truth) were 0.865 ± 0.037. In comparison, the Dice coefficients between ground-truth and contours generated using deformable registration based methods were 0.909 ± 0.051. Conclusions. The MPSL method achieved similar segmentation accuracy as compared to state-of-the-art deformable registration based segmentation methods, but with significant reduction in time required for GTV segmentation.

  17. Rapid Automated Target Segmentation and Tracking on 4D Data without Initial Contours

    Directory of Open Access Journals (Sweden)

    Venkata V. Chebrolu

    2014-01-01

    Full Text Available Purpose. To achieve rapid automated delineation of gross target volume (GTV and to quantify changes in volume/position of the target for radiotherapy planning using four-dimensional (4D CT. Methods and Materials. Novel morphological processing and successive localization (MPSL algorithms were designed and implemented for achieving autosegmentation. Contours automatically generated using MPSL method were compared with contours generated using state-of-the-art deformable registration methods (using Elastix© and MIMVista software. Metrics such as the Dice similarity coefficient, sensitivity, and positive predictive value (PPV were analyzed. The target motion tracked using the centroid of the GTV estimated using MPSL method was compared with motion tracked using deformable registration methods. Results. MPSL algorithm segmented the GTV in 4DCT images in 27.0±11.1 seconds per phase (512×512 resolution as compared to 142.3±11.3 seconds per phase for deformable registration based methods in 9 cases. Dice coefficients between MPSL generated GTV contours and manual contours (considered as ground-truth were 0.865±0.037. In comparison, the Dice coefficients between ground-truth and contours generated using deformable registration based methods were 0.909 ± 0.051. Conclusions. The MPSL method achieved similar segmentation accuracy as compared to state-of-the-art deformable registration based segmentation methods, but with significant reduction in time required for GTV segmentation.

  18. Rapid Automated Target Segmentation and Tracking on 4D Data without Initial Contours.

    Science.gov (United States)

    Chebrolu, Venkata V; Saenz, Daniel; Tewatia, Dinesh; Sethares, William A; Cannon, George; Paliwal, Bhudatt R

    2014-01-01

    Purpose. To achieve rapid automated delineation of gross target volume (GTV) and to quantify changes in volume/position of the target for radiotherapy planning using four-dimensional (4D) CT. Methods and Materials. Novel morphological processing and successive localization (MPSL) algorithms were designed and implemented for achieving autosegmentation. Contours automatically generated using MPSL method were compared with contours generated using state-of-the-art deformable registration methods (using Elastix© and MIMVista software). Metrics such as the Dice similarity coefficient, sensitivity, and positive predictive value (PPV) were analyzed. The target motion tracked using the centroid of the GTV estimated using MPSL method was compared with motion tracked using deformable registration methods. Results. MPSL algorithm segmented the GTV in 4DCT images in 27.0 ± 11.1 seconds per phase (512 × 512 resolution) as compared to 142.3 ± 11.3 seconds per phase for deformable registration based methods in 9 cases. Dice coefficients between MPSL generated GTV contours and manual contours (considered as ground-truth) were 0.865 ± 0.037. In comparison, the Dice coefficients between ground-truth and contours generated using deformable registration based methods were 0.909 ± 0.051. Conclusions. The MPSL method achieved similar segmentation accuracy as compared to state-of-the-art deformable registration based segmentation methods, but with significant reduction in time required for GTV segmentation.

  19. Contour analysis of steady state tokamak reactor performance

    International Nuclear Information System (INIS)

    Devoto, R.S.; Fenstermacher, M.E.

    1990-01-01

    A new method of analysis for presenting the possible operating space for steady state, non-ignited tokamak reactors is proposed. The method uses contours of reactor performance and plasma characteristics, fusion power gain, wall neutron flux, current drive power, etc., plotted on a two-dimensional grid, the axes of which are the plasma current I p and the normalized beta, β n = β/(I p /aB 0 ), to show possible operating points. These steady state operating contour plots are called SOPCONS. This technique is illustrated in an application to a design for the International Thermonuclear Experimental Reactor (ITER) with neutral beam, lower hybrid and bootstrap current drive. The utility of the SOPCON plots for pointing out some of the non-intuitive considerations in steady state reactor design is shown. (author). Letter-to-the-editor. 16 refs, 3 figs, 1 tab

  20. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  1. Efficient Active Contour and K-Means Algorithms in Image Segmentation

    Directory of Open Access Journals (Sweden)

    J.R. Rommelse

    2004-01-01

    Full Text Available In this paper we discuss a classic clustering algorithm that can be used to segment images and a recently developed active contour image segmentation model. We propose integrating aspects of the classic algorithm to improve the active contour model. For the resulting CVK and B-means segmentation algorithms we examine methods to decrease the size of the image domain. The CVK method has been implemented to run on parallel and distributed computers. By changing the order of updating the pixels, it was possible to replace synchronous communication with asynchronous communication and subsequently the parallel efficiency is improved.

  2. Contour Tracking Control for the REMUS Autonomous Underwater Vehicle

    National Research Council Canada - National Science Library

    Van Reet, Alan R

    2005-01-01

    In the interest of enhancing the capabilities of autonomous underwater vehicles used in US Naval Operations, controlling vehicle position to follow depth contours presents exciting potential for navigation...

  3. Determination of aortic compliance from magnetic resonance images using an automatic active contour model

    International Nuclear Information System (INIS)

    Krug, Roland; Boese, Jan M; Schad, Lothar R

    2003-01-01

    The possibility of monitoring changes in aortic elasticity in humans has important applications for clinical trials because it estimates the efficacy of plaque-reducing therapies. The elasticity is usually quantified by compliance measurements. Therefore, the relative temporal change in the vessel cross-sectional area throughout the cardiac cycle has to be determined. In this work we determined and compared the compliance between three magnetic resonance (MR) methods (FLASH, TrueFISP and pulse-wave). Since manual outlining of the aortic wall area is a very time-consuming process and depends on an operator's variability, an algorithm for the automatic segmentation of the artery wall from MR images through the entire heart cycle is presented. The reliable detection of the artery cross-sectional area over the whole heart cycle was possible with a relative error of about 1%. Optimizing the temporal resolution to 60 ms we obtained a relative error in compliance of about 7% from TrueFISP (1.0 x 1.0 x 10 mm 3 , signal-to-noise ratio (SNR) > 12) and FLASH (0.7 x 0.7 x 10 mm 3 , SNR > 12) measurements in volunteers. Pulse-wave measurements yielded an error of more than 9%. In a study of ten volunteers, a compliance between C = 3 x 10 -5 Pa -1 and C = 8 x 10 -5 Pa -1 was determined, depending on age. The results of the TrueFISP and the pulse-wave measurements agreed very well with one another (confidence interval of 1 x 10 -5 Pa -1 ) while the results of the FLASH method more clearly deviated from the TrueFISP and pulse-wave (confidence interval of more than 2 x 10 -5 Pa -1 )

  4. Contour detection based on nonclassical receptive field inhibition

    NARCIS (Netherlands)

    Grigorescu, Cosmin; Petkov, Nicolai; Westenberg, Michel A.

    We propose a biologically motivated computational step, called nonclassical receptive field (non-CRF) inhibition, more generally surround inhibition or suppression, to improve contour detection in machine vision. Non-CRF inhibition is exhibited by 80% of the orientation-selective neurons in the

  5. Multiple Active Contours Guided by Differential Evolution for Medical Image Segmentation

    Science.gov (United States)

    Cruz-Aceves, I.; Avina-Cervantes, J. G.; Lopez-Hernandez, J. M.; Rostro-Gonzalez, H.; Garcia-Capulin, C. H.; Torres-Cisneros, M.; Guzman-Cabrera, R.

    2013-01-01

    This paper presents a new image segmentation method based on multiple active contours guided by differential evolution, called MACDE. The segmentation method uses differential evolution over a polar coordinate system to increase the exploration and exploitation capabilities regarding the classical active contour model. To evaluate the performance of the proposed method, a set of synthetic images with complex objects, Gaussian noise, and deep concavities is introduced. Subsequently, MACDE is applied on datasets of sequential computed tomography and magnetic resonance images which contain the human heart and the human left ventricle, respectively. Finally, to obtain a quantitative and qualitative evaluation of the medical image segmentations compared to regions outlined by experts, a set of distance and similarity metrics has been adopted. According to the experimental results, MACDE outperforms the classical active contour model and the interactive Tseng method in terms of efficiency and robustness for obtaining the optimal control points and attains a high accuracy segmentation. PMID:23983809

  6. Multiple Active Contours Guided by Differential Evolution for Medical Image Segmentation

    Directory of Open Access Journals (Sweden)

    I. Cruz-Aceves

    2013-01-01

    Full Text Available This paper presents a new image segmentation method based on multiple active contours guided by differential evolution, called MACDE. The segmentation method uses differential evolution over a polar coordinate system to increase the exploration and exploitation capabilities regarding the classical active contour model. To evaluate the performance of the proposed method, a set of synthetic images with complex objects, Gaussian noise, and deep concavities is introduced. Subsequently, MACDE is applied on datasets of sequential computed tomography and magnetic resonance images which contain the human heart and the human left ventricle, respectively. Finally, to obtain a quantitative and qualitative evaluation of the medical image segmentations compared to regions outlined by experts, a set of distance and similarity metrics has been adopted. According to the experimental results, MACDE outperforms the classical active contour model and the interactive Tseng method in terms of efficiency and robustness for obtaining the optimal control points and attains a high accuracy segmentation.

  7. Identifying coronary artery disease in asymptomatic middle-aged sportsmen : The additional value of pulse wave velocity

    NARCIS (Netherlands)

    Braber, Thijs L.; Prakken, Niek H J; Mosterd, Arend; Mali, Willem P Th M; Doevendans, Pieter A F M; Bots, Michiel L.; Velthuis, Birgitta K.

    2015-01-01

    Background: Cardiovascular screening may benefit middle-aged sportsmen, as coronary artery disease (CAD) is the main cause of exercise-related sudden cardiac death. Arterial stiffness, as measured by pulse wave velocity (PWV), may help identify sportsmen with subclinical CAD. We examined the

  8. Automatic contouring of geologic fabric and finite strain data on the unit hyperboloid

    Science.gov (United States)

    Vollmer, Frederick W.

    2018-06-01

    Fabric and finite strain analysis, an integral part of studies of geologic structures and orogenic belts, is commonly done by the analysis of particles whose shapes can be approximated as ellipses. Given a sample of such particles, the mean and confidence intervals of particular parameters can be calculated, however, taking the extra step of plotting and contouring the density distribution can identify asymmetries or modes related to sedimentary fabrics or other factors. A common graphical strain analysis technique is to plot final ellipse ratios, Rf , versus orientations, ϕf on polar Elliott or Rf / ϕ plots to examine the density distribution. The plot may be contoured, however, it is desirable to have a contouring method that is rapid, reproducible, and based on the underlying geometry of the data. The unit hyperboloid, H2 , gives a natural parameter space for two-dimensional strain, and various projections, including equal-area and stereographic, have useful properties for examining density distributions for anisotropy. An index, Ia , is given to quantify the magnitude and direction of anisotropy. Elliott and Rf / ϕ plots can be understood by applying hyperbolic geometry and recognizing them as projections of H2 . These both distort area, however, so the equal-area projection is preferred for examining density distributions. The algorithm presented here gives fast, accurate, and reproducible contours of density distributions calculated directly on H2 . The algorithm back-projects the data onto H2 , where the density calculation is done at regular nodes using a weighting value based on the hyperboloid distribution, which is then contoured. It is implemented as an Octave compatible MATLAB function that plots ellipse data using a variety of projections, and calculates and displays contours of their density distribution on H2 .

  9. Automatic cumulative sums contour detection of FBP-reconstructed multi-object nuclear medicine images.

    Science.gov (United States)

    Protonotarios, Nicholas E; Spyrou, George M; Kastis, George A

    2017-06-01

    The problem of determining the contours of objects in nuclear medicine images has been studied extensively in the past, however most of the analysis has focused on a single object as opposed to multiple objects. The aim of this work is to develop an automated method for determining the contour of multiple objects in positron emission tomography (PET) and single photon emission computed tomography (SPECT) filtered backprojection (FBP) reconstructed images. These contours can be used for computing body edges for attenuation correction in PET and SPECT, as well as for eliminating streak artifacts outside the objects, which could be useful in compressive sensing reconstruction. Contour detection has been accomplished by applying a modified cumulative sums (CUSUM) scheme in the sinogram. Our approach automatically detects all objects in the image, without requiring a priori knowledge of the number of distinct objects in the reconstructed image. This method has been tested in simulated phantoms, such as an image-quality (IQ) phantom and two digital multi-object phantoms, as well as a real NEMA phantom and a clinical thoracic study. For this purpose, a GE Discovery PET scanner was employed. The detected contours achieved root mean square accuracy of 1.14 pixels, 1.69 pixels and 3.28 pixels and a Hausdorff distance of 3.13, 3.12 and 4.50 pixels, for the simulated image-quality phantom PET study, the real NEMA phantom and the clinical thoracic study, respectively. These results correspond to a significant improvement over recent results obtained in similar studies. Furthermore, we obtained an optimal sub-pattern assignment (OSPA) localization error of 0.94 and 1.48, for the two-objects and three-objects simulated phantoms, respectively. Our method performs efficiently for sets of convex objects and hence it provides a robust tool for automatic contour determination with precise results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. 30 CFR 785.16 - Permits incorporating variances from approximate original contour restoration requirements for...

    Science.gov (United States)

    2010-07-01

    ... approximate original contour restoration requirements for steep slope mining. 785.16 Section 785.16 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL... approximate original contour restoration requirements for steep slope mining. (a) The regulatory authority may...

  11. Iterative Method of Regularization with Application of Advanced Technique for Detection of Contours

    International Nuclear Information System (INIS)

    Niedziela, T.; Stankiewicz, A.

    2000-01-01

    This paper proposes a novel iterative method of regularization with application of an advanced technique for detection of contours. To eliminate noises, the properties of convolution of functions are utilized. The method can be accomplished in a simple neural cellular network, which creates the possibility of extraction of contours by automatic image recognition equipment. (author)

  12. ANALYTICAL ENGINEERING OF A TELECONTROLLED PILOTLESS AIRCRAFT CONTOUR IN ACCORDANCE WITH GENERALIZED WORK CRITERION

    Directory of Open Access Journals (Sweden)

    A. M. Eromin

    2015-01-01

    Full Text Available The article considers the non­terminal problem for neutral contour of a telecontrolled pilotless aircraft. Optimal control synthesis is provided on the basis of minimization of generalized work functional. The analysis of optimal telecontrolled pilotless aircraft contour is carried out.

  13. Segmentation of breast ultrasound images based on active contours using neutrosophic theory.

    Science.gov (United States)

    Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A

    2018-04-01

    Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.

  14. Optimization of process parameters of pulsed TIG welded maraging steel C300

    Science.gov (United States)

    Deepak, P.; Jualeash, M. J.; Jishnu, J.; Srinivasan, P.; Arivarasu, M.; Padmanaban, R.; Thirumalini, S.

    2016-09-01

    Pulsed TIG welding technology provides excellent welding performance on thin sections which helps to increase productivity, enhance weld quality, minimize weld costs, and boost operator efficiency and this has drawn the attention of the welding society. Maraging C300 steel is extensively used in defence and aerospace industry and thus its welding becomes an area of paramount importance. In pulsed TIG welding, weld quality depends on the process parameters used. In this work, Pulsed TIG bead-on-plate welding is performed on a 5mm thick maraging C300 plate at different combinations of input parameters: peak current (Ip), base current (Ib) and pulsing frequency (HZ) as per box behnken design with three-levels for each factor. Response surface methodology is utilized for establishing a mathematical model for predicting the weld bead depth. The effect of Ip, Ib and HZ on the weld bead depth is investigated using the developed model. The weld bead depth is found to be affected by all the three parameters. Surface and contour plots developed from regression equation are used to optimize the processing parameters for maximizing the weld bead depth. Optimum values of Ip, Ib and HZ are obtained as 259 A, 120 A and 8 Hz respectively. Using this optimum condition, maximum bead depth of the weld is predicted to be 4.325 mm.

  15. SU-E-E-05: Improving Contouring Precision and Consistency for Physicians-In-Training with Simple Lab Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ma, L; Larson, D A [University of California School of Medicine, San Francisco, CA (United States)

    2015-06-15

    Purpose: Target contouring for high-dose treatments such as radiosurgery of brain metastases is highly critical in eliminating marginal failure and reducing complications as shown by recent clinical studies. In order to improve contouring accuracy and practice consistency for the procedure, we introduced a self-assessed physics lab practice for the physicians-in-training. Methods: A set of commercially acquired high-precision PMMA plastic spheres were randomly embedded in a Styrofoam block and then scanned with the CT/MR via the clinical procedural imaging protocol. A group of first-year physicians-in-training (n=6) from either neurosurgery or radiation oncology department were asked to contour the scanned objects (diameter ranged from 0.4 cm to 3.8 cm). These user-defined contours were then compared with the ideal contour sets of object shape for self assessments to determine the maximum areas of the observed discrepancies and method of improvements. Results: The largest discrepancies from initial practice were consistently found to be located near the extreme longitudinal portions of the target for all the residents. Discrepancy was especially prominent when contouring small objects < 1.0 cm in diameters. For example, the mean volumes rendered from the initial contour data set differed from the ideal data set by 7.7%±6.6% for the participants (p> 0.23 suggesting agreement cannot be established). However, when incorporating a secondary imaging scan such as reconstructed coronal or sagittal images in a repeat practice, the agreement was dramatically improved yielding p<0.02 in agreement with the reference data set for all the participants. Conclusion: A simple physics lab revealed a common pitfall in contouring small metastatic brain tumors for radiosurgical procedures and provided a systematic tool for physicians-in-training in improving their clinical contouring skills. Dr Ma is current a board member of international stereotactic radiosurgical society.

  16. Strain-induced fermi contour anisotropy of GaAs 2D holes.

    Science.gov (United States)

    Shabani, J; Shayegan, M; Winkler, R

    2008-03-07

    We report measurements of magnetoresistance commensurability peaks, induced by a square array of antidots, in GaAs (311)A two-dimensional holes as a function of applied in-plane strain. The data directly probe the shapes of the Fermi contours of the two spin subbands that are split thanks to the spin-orbit interaction and strain. The experimental results are in quantitative agreement with the predictions of accurate energy band calculations, and reveal that the majority spin subband has a severely distorted Fermi contour whose anisotropy can be tuned with strain.

  17. Halogenated anaesthetics and cardiac protection in cardiac and non-cardiac anaesthesia

    Directory of Open Access Journals (Sweden)

    Landoni Giovanni

    2009-01-01

    Full Text Available Volatile anaesthetic agents have direct protective properties against ischemic myocardial damage. The implementation of these properties during clinical anaesthesia can provide an additional tool in the treatment or prevention, or both, of ischemic cardiac dysfunction in the perioperative period. A recent meta-analysis showed that desflurane and sevoflurane reduce postoperative mortality and incidence of myocardial infarction following cardiac surgery, with significant advantages in terms of postoperative cardiac troponin release, need for inotrope support, time on mechanical ventilation, intensive care unit and overall hospital stay. Multicentre, randomised clinical trials had previously demonstrated that the use of desflurane can reduce the postoperative release of cardiac troponin I, the need for inotropic support, and the number of patients requiring prolonged hospitalisation following coronary artery bypass graft surgery either with and without cardiopulmonary bypass. The American College of Cardiology/American Heart Association Guidelines recommend volatile anaesthetic agents during non-cardiac surgery for the maintenance of general anaesthesia in patients at risk for myocardial infarction. Nonetheless, e vidence in non-coronary surgical settings is contradictory and will be reviewed in this paper together with the mechanisms of cardiac protection by volatile agents.

  18. Pulse Wave Variation during the Menstrual Cycle in Women with Menstrual Pain

    Directory of Open Access Journals (Sweden)

    Soo Hyung Jeon

    2016-01-01

    Full Text Available Objective. This study is performed to obtain objective diagnostic indicators associated with menstrual pain using pulse wave analysis. Methods. Using a pulse diagnostic device, we measured the pulse waves of 541 women aged between 19 and 30 years, placed in either an experimental group with menstrual pain (n=329 or a control group with little or no menstrual pain (n=212. Measurements were taken during both the menstrual and nonmenstrual periods, and comparative analysis was performed. Results. During the nonmenstrual period, the experimental group showed a significantly higher value in the left radial artery for the radial augmentation index (RAI (p=0.050 but significantly lower values for pulse wave energy (p=0.021 and time to first peak from baseline (T1 (p=0.035 in the right radial artery. During the menstrual period, the experimental group showed significantly lower values in the left radial artery for cardiac diastole and pulse wave area during diastole and significantly higher values for pulse wave area during systole, ratio of systolic phase to the full heartbeat, and systolic-diastolic ratio. Conclusion. We obtained indicators of menstrual pain in women during the menstrual period, including prolonged systolic and shortened diastolic phases, increases in pulse wave energy and area of representative pulse wave, and increased blood vessel resistance.

  19. Total lymphoid irradiation for treatment of intractable cardiac allograft rejection

    International Nuclear Information System (INIS)

    Hunt, S.A.; Strober, S.; Hoppe, R.T.; Stinson, E.B.

    1991-01-01

    The ability of postoperative total lymphoid irradiation to reverse otherwise intractable cardiac allograft rejection was examined in a group of 10 patients in whom conventional rejection therapy (including pulsed steroids and monoclonal or polyclonal anti-T-cell antibody therapy) had failed to provide sustained freedom from rejection. Follow-up periods range from 73 to 1119 days since the start of total lymphoid irradiation. No patient died or sustained serious morbidity because of the irradiation. Three patients have had no further rejection (follow-up periods, 105 to 365 days). Two patients died--one in cardiogenic shock during the course of total lymphoid irradiation, the other with recurrent rejection caused by noncompliance with his medical regimen. Total lymphoid irradiation appears to be a safe and a moderately effective immunosuppressive modality for 'salvage' therapy of cardiac allograft rejection unresponsive to conventional therapy

  20. Free-convective flow of fluid in a thin porous contour and geothermal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Magomedbekov Kh.G.; Ramazanov, M.M.; Vagabov, M.V.

    1996-01-24

    The problem of free convection in a thin porous contour, placed in uniform impermeable massif is considered. The approximate analitical solution of conjugate problem is obtained. The critical Rayleigh number is determined, by exceeding of which the steady fluid circulation in an annulus is established. The computations of abnormal heat flow near surface are carried out, stipulated by thermoconvection in a contour.

  1. Modelling cardiac signal as a confound in EEG-fMRI and its application in focal epilepsy studies

    DEFF Research Database (Denmark)

    Liston, A. D.; Ellegaard Lund, Torben; Salek-Haddadi, A

    2006-01-01

    effects to be modelled, as effects of no interest. Our model is based on an over-complete basis set covering a linear relationship between cardiac-related MR signal and the phase of the cardiac cycle or time after pulse (TAP). This method showed that, on average, 24.6 +/- 10.9% of grey matter voxels......Cardiac noise has been shown to reduce the sensitivity of functional Magnetic Resonance Imaging (fMRI) to an experimental effect due to its confounding presence in the blood oxygenation level-dependent (BOLD) signal. Its effect is most severe in particular regions of the brain and a method is yet...... to take it into account in routine fMRI analysis. This paper reports the development of a general and robust technique to improve the reliability of EEG-fMRI studies to BOLD signal correlated with interictal epileptiform discharges (IEDs). In these studies, ECG is routinely recorded, enabling cardiac...

  2. Directional harmonic theory: a computational Gestalt model to account for illusory contour and vertex formation.

    Science.gov (United States)

    Lehar, Steven

    2003-01-01

    Visual illusions and perceptual grouping phenomena offer an invaluable tool for probing the computational mechanism of low-level visual processing. Some illusions, like the Kanizsa figure, reveal illusory contours that form edges collinear with the inducing stimulus. This kind of illusory contour has been modeled by neural network models by way of cells equipped with elongated spatial receptive fields designed to detect and complete the collinear alignment. There are, however, other illusory groupings which are not so easy to account for in neural network terms. The Ehrenstein illusion exhibits an illusory contour that forms a contour orthogonal to the stimulus instead of collinear with it. Other perceptual grouping effects reveal illusory contours that exhibit a sharp corner or vertex, and still others take the form of vertices defined by the intersection of three, four, or more illusory contours that meet at a point. A direct extension of the collinear completion models to account for these phenomena tends towards a combinatorial explosion, because it would suggest cells with specialized receptive fields configured to perform each of those completion types, each of which would have to be replicated at every location and every orientation across the visual field. These phenomena therefore challenge the adequacy of the neural network approach to account for these diverse perceptual phenomena. I have proposed elsewhere an alternative paradigm of neurocomputation in the harmonic resonance theory (Lehar 1999, see website), whereby pattern recognition and completion are performed by spatial standing waves across the neural substrate. The standing waves perform a computational function analogous to that of the spatial receptive fields of the neural network approach, except that, unlike that paradigm, a single resonance mechanism performs a function equivalent to a whole array of spatial receptive fields of different spatial configurations and of different orientations

  3. Detection of cardiac activity changes from human speech

    Science.gov (United States)

    Tovarek, Jaromir; Partila, Pavol; Voznak, Miroslav; Mikulec, Martin; Mehic, Miralem

    2015-05-01

    Impact of changes in blood pressure and pulse from human speech is disclosed in this article. The symptoms of increased physical activity are pulse, systolic and diastolic pressure. There are many methods of measuring and indicating these parameters. The measurements must be carried out using devices which are not used in everyday life. In most cases, the measurement of blood pressure and pulse following health problems or other adverse feelings. Nowadays, research teams are trying to design and implement modern methods in ordinary human activities. The main objective of the proposal is to reduce the delay between detecting the adverse pressure and to the mentioned warning signs and feelings. Common and frequent activity of man is speaking, while it is known that the function of the vocal tract can be affected by the change in heart activity. Therefore, it can be a useful parameter for detecting physiological changes. A method for detecting human physiological changes by speech processing and artificial neural network classification is described in this article. The pulse and blood pressure changes was induced by physical exercises in this experiment. The set of measured subjects was formed by ten healthy volunteers of both sexes. None of the subjects was a professional athlete. The process of the experiment was divided into phases before, during and after physical training. Pulse, systolic, diastolic pressure was measured and voice activity was recorded after each of them. The results of this experiment describe a method for detecting increased cardiac activity from human speech using artificial neural network.

  4. Quality of life long-term after body contouring surgery following bariatric surgery: sustained improvement after 7 years.

    Science.gov (United States)

    van der Beek, Eva S J; Geenen, Rinie; de Heer, Francine A G; van der Molen, Aebele B Mink; van Ramshorst, Bert

    2012-11-01

    Bariatric surgery for morbid obesity results in massive weight loss and improvement of health and quality of life. A downside of the major weight loss is the excess of overstretched skin, which may influence the patient's quality of life by causing functional and aesthetic problems. The purpose of the current study was to evaluate the patient's quality of life long-term after body contouring following bariatric surgery. Quality of life was measured with the Obesity Psychosocial State Questionnaire in 33 post-bariatric surgery patients 7.2 years (range, 3.2 to 13.3 years) after body contouring surgery. Data were compared with previous assessments 4.1 years (range, 0.7 to 9.2 years) after body contouring surgery of the quality of life at that time and before body contouring surgery. Compared with appraisals of quality of life before body contouring surgery, a significant, mostly moderate to large, sustained improvement of quality of life was observed in post-bariatric surgery patients 7.2 years after body contouring surgery in six of the seven psychosocial domains. A small deterioration occurred between 4.1- and 7.2-year follow-up on two of the seven domains except for the domain efficacy toward eating, which showed a significant improvement. At 7-year follow-up, 18 patients (55 percent) were satisfied with the result of body contouring surgery. This study indicates a sustained quality-of-life improvement in post-bariatric surgery patients after body contouring surgery. This suggests the importance of including reconstructive surgery as a component in the multidisciplinary approach in the surgical treatment of morbid obesity. Therapeutic, IV.

  5. Development and Validation of Consensus Contouring Guidelines for Adjuvant Radiation Therapy for Bladder Cancer After Radical Cystectomy

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Brian C. [Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Bosch, Walter R. [Washington University in St. Louis, St. Louis, Missouri (United States); Bahl, Amit [University Hospitals Bristol NHS Foundation Trust, Bristol (United Kingdom); Birtle, Alison J. [Royal Preston Hospital, Preston (United Kingdom); Breau, Rodney H. [University of Ottawa, Ottawa, Ontario (Canada); Challapalli, Amarnath [University Hospitals Bristol NHS Foundation Trust, Bristol (United Kingdom); Chang, Albert J. [University of California San Francisco, San Francisco, California (United States); Choudhury, Ananya [Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester (United Kingdom); The University of Manchester, Manchester Academic Heath Science Centre, Manchester (United Kingdom); Daneshmand, Sia [University of Southern California, Los Angeles, California (United States); El-Gayed, Ali [Saskatoon Cancer Centre, Saskatoon (Canada); Feldman, Adam [Massachusetts General Hospital, Boston, Massachusetts (United States); Finkelstein, Steven E. [Cancer Treatment Centers of America, Tulsa, Oklahoma (United States); Guzzo, Thomas J. [Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Hilman, Serena [University Hospitals Bristol NHS Foundation Trust, Bristol (United Kingdom); Jani, Ashesh [Emory University, Atlanta, Georgia (United States); Malkowicz, S. Bruce [Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania (United States); Mantz, Constantine A. [21st Century Oncology, Scottsdale, Arizona (United States); 21st Century Oncology, Fort Myers, Florida (United States); Master, Viraj [Emory University, Atlanta, Georgia (United States); Mitra, Anita V. [University College London Hospital, London (United Kingdom); Murthy, Vedang [Tata Memorial Center, Mumbai (India); and others

    2016-09-01

    Purpose: To develop multi-institutional consensus clinical target volumes (CTVs) and organs at risk (OARs) for male and female bladder cancer patients undergoing adjuvant radiation therapy (RT) in clinical trials. Methods and Materials: We convened a multidisciplinary group of bladder cancer specialists from 15 centers and 5 countries. Six radiation oncologists and 7 urologists participated in the development of the initial contours. The group proposed initial language for the CTVs and OARs, and each radiation oncologist contoured them on computed tomography scans of a male and female cystectomy patient with input from ≥1 urologist. On the basis of the initial contouring, the group updated its CTV and OAR descriptions. The cystectomy bed, the area of greatest controversy, was contoured by another 6 radiation oncologists, and the cystectomy bed contouring language was again updated. To determine whether the revised language produced consistent contours, CTVs and OARs were redrawn by 6 additional radiation oncologists. We evaluated their contours for level of agreement using the Landis-Koch interpretation of the κ statistic. Results: The group proposed that patients at elevated risk for local-regional failure with negative margins should be treated to the pelvic nodes alone (internal/external iliac, distal common iliac, obturator, and presacral), whereas patients with positive margins should be treated to the pelvic nodes and cystectomy bed. Proposed OARs included the rectum, bowel space, bone marrow, and urinary diversion. Consensus language describing the CTVs and OARs was developed and externally validated. The revised instructions were found to produce consistent contours. Conclusions: Consensus descriptions of CTVs and OARs were successfully developed and can be used in clinical trials of adjuvant radiation therapy for bladder cancer.

  6. Field-level financial assessment of contour prairie strips for enhancement of environmental quality.

    Science.gov (United States)

    Tyndall, John C; Schulte, Lisa A; Liebman, Matthew; Helmers, Matthew

    2013-09-01

    The impacts of strategically located contour prairie strips on sediment and nutrient runoff export from watersheds maintained under an annual row crop production system have been studied at a long-term research site in central Iowa. Data from 2007 to 2011 indicate that the contour prairie strips utilized within row crop-dominated landscapes have greater than proportionate and positive effects on the functioning of biophysical systems. Crop producers and land management agencies require comprehensive information about the Best Management Practices with regard to performance efficacy, operational/management parameters, and the full range of financial parameters. Here, a farm-level financial model assesses the establishment, management, and opportunity costs of contour prairie strips within cropped fields. Annualized, depending on variable opportunity costs the 15-year present value cost of utilizing contour prairie strips ranges from $590 to $865 ha(-1) year(-1) ($240-$350 ac(-1) year(-1)). Expressed in the context of "treatment area" (e.g., in this study 1 ha of prairie treats 10 ha of crops), the costs of contour prairie strips can also be viewed as $59 to about $87 per treated hectare ($24-$35 ac(-1)). If prairie strips were under a 15-year CRP contract, total per acre cost to farmers would be reduced by over 85 %. Based on sediment, phosphorus, and nitrogen export data from the related field studies and across low, medium, and high land rent scenarios, a megagram (Mg) of soil retained within the watershed costs between $7.79 and $11.46 mg(-1), phosphorus retained costs between $6.97 and $10.25 kg(-1), and nitrogen retained costs between $1.59 and $2.34 kg(-1). Based on overall project results, contour prairie strips may well become one of the key conservation practices used to sustain US Corn Belt agriculture in the decades to come.

  7. Pseudo-Hermitian description of PT-symmetric systems defined on a complex contour

    International Nuclear Information System (INIS)

    Mostafazadeh, Ali

    2005-01-01

    We describe a method that allows for a practical application of the theory of pseudo-Hermitian operators to PT-symmetric systems defined on a complex contour. We apply this method to study the Hamiltonians H = p 2 + x 2 (ix) ν with ν ε (-2, ∞) that are defined along the corresponding anti-Stokes lines. In particular, we reveal the intrinsic non-Hermiticity of H for the cases that ν is an even integer, so that H p 2 ± x 2+ν , and give a proof of the discreteness of the spectrum of H for all ν ε (-2, ∞). Furthermore, we study the consequences of defining a square-well Hamiltonian on a wedge-shaped complex contour. This yields a PT-symmetric system with a finite number of real eigenvalues. We present a comprehensive analysis of this system within the framework of pseudo-Hermitian quantum mechanics. We also outline a direct pseudo-Hermitian treatment of PT-symmetric systems defined on a complex contour which clarifies the underlying mathematical structure of the formulation of PT-symmetric quantum mechanics based on the charge-conjugation operator. Our results provide conclusive evidence that pseudo-Hermitian quantum mechanics provides a complete description of general PT-symmetric systems regardless of whether they are defined along the real line or a complex contour

  8. DEVELOPMENT OF VISUALLY GUIDED BEHAVIOR REQUIRES ORIENTED CONTOURS

    NARCIS (Netherlands)

    BRENNER, E; CORNELISSEN, FW

    1992-01-01

    Kittens do not learn to use visual information to guide their behaviour if they are deprived of the optic flow that accompanies their own movements. We show that the optic flow that is required for developing visually guided behaviour is derived from changes in contour orientations, rather than from

  9. Assessment of interchangeability rate between 2 methods of measurements: An example with a cardiac output comparison study.

    Science.gov (United States)

    Lorne, Emmanuel; Diouf, Momar; de Wilde, Robert B P; Fischer, Marc-Olivier

    2018-02-01

    The Bland-Altman (BA) and percentage error (PE) methods have been previously described to assess the agreement between 2 methods of medical or laboratory measurements. This type of approach raises several problems: the BA methodology constitutes a subjective approach to interchangeability, whereas the PE approach does not take into account the distribution of values over a range. We describe a new methodology that defines an interchangeability rate between 2 methods of measurement and cutoff values that determine the range of interchangeable values. We used a simulated data and a previously published data set to demonstrate the concept of the method. The interchangeability rate of 5 different cardiac output (CO) pulse contour techniques (Wesseling method, LiDCO, PiCCO, Hemac method, and Modelflow) was calculated, in comparison with the reference pulmonary artery thermodilution CO using our new method. In our example, Modelflow with a good interchangeability rate of 93% and a cutoff value of 4.8 L min, was found to be interchangeable with the thermodilution method for >95% of measurements. Modelflow had a higher interchangeability rate compared to Hemac (93% vs 86%; P = .022) or other monitors (Wesseling cZ = 76%, LiDCO = 73%, and PiCCO = 62%; P < .0001). Simulated data and reanalysis of a data set comparing 5 CO monitors against thermodilution CO showed that, depending on the repeatability of the reference method, the interchangeability rate combined with a cutoff value could be used to define the range of values over which interchangeability remains acceptable.

  10. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  11. Anatomically contoured plates for fixation of rib fractures.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  12. Pulse Oximetry and Auscultation for Congenital Heart Disease Detection.

    Science.gov (United States)

    Hu, Xiao-Jing; Ma, Xiao-Jing; Zhao, Qu-Ming; Yan, Wei-Li; Ge, Xiao-Ling; Jia, Bing; Liu, Fang; Wu, Lin; Ye, Ming; Liang, Xue-Cun; Zhang, Jing; Gao, Yan; Zhai, Xiao-Wen; Huang, Guo-Ying

    2017-10-01

    Pulse oximetry (POX) has been confirmed as a specific screening modality for critical congenital heart disease (CCHD), with moderate sensitivity. However, POX is not able to detect most serious and critical cardiac lesions (major congenital heart disease [CHD]) without hypoxemia. In this study, we investigated the accuracy and feasibility of the addition of cardiac auscultation to POX as a screening method for asymptomatic major CHD. A multicenter prospective observational screening study was conducted at 15 hospitals in Shanghai between July 1, 2012, and December 31, 2014. Newborns with either an abnormal POX or cardiac auscultation were defined as screen positive. All screen-positive newborns underwent further echocardiography. False-negative results were identified by clinical follow-up, parents' feedback, and telephone review. We assessed the accuracy of POX plus cardiac auscultation for the detection of major CHD. CHD screening was completed in all 15 hospitals, with a screening rate of 94.0% to 99.8%. In total, 167 190 consecutive asymptomatic newborn infants were screened, of which 203 had major CHD (44 critical and 159 serious). The sensitivity of POX plus cardiac auscultation was 95.5% (95% confidence interval 84.9%-98.7%) for CCHD and 92.1% (95% confidence interval 87.7%-95.1%) for major CHD. The false-positive rate was 1.2% for detecting CCHD and 1.1% for detecting major CHD. In our current study, we show that using POX plus cardiac auscultation significantly improved the detection rate of major CHD in the early neonatal stage, with high sensitivity and a reasonable false-positive rate. It provides strong evidence and a reliable method for neonatal CHD screening. Copyright © 2017 by the American Academy of Pediatrics.

  13. Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy

    Science.gov (United States)

    Yeap, P. L.; Noble, D. J.; Harrison, K.; Bates, A. M.; Burnet, N. G.; Jena, R.; Romanchikova, M.; Sutcliffe, M. P. F.; Thomas, S. J.; Barnett, G. C.; Benson, R. J.; Jefferies, S. J.; Parker, M. A.

    2017-08-01

    To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is 0.759 +/- 0.003 , and the median DBC is (0.87 +/- 0.01 ) mm. An intra-observer comparison for the same scans gives a median CI of 0.820 +/- 0.002 and a DBC of (0.64 +/- 0.01 ) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.

  14. Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy.

    Science.gov (United States)

    Yeap, P L; Noble, D J; Harrison, K; Bates, A M; Burnet, N G; Jena, R; Romanchikova, M; Sutcliffe, M P F; Thomas, S J; Barnett, G C; Benson, R J; Jefferies, S J; Parker, M A

    2017-07-12

    To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.

  15. Memory for pure tone sequences without contour.

    Science.gov (United States)

    Lefebvre, Christine; Jolicœur, Pierre

    2016-06-01

    We presented pure tones interspersed with white noise sounds to disrupt contour perception in an acoustic short-term memory (ASTM) experiment during which we recorded the electroencephalogram. The memory set consisted of seven stimuli, 0, 1, 2, 3, or 4 of which were to-be-remembered tones. We estimated each participant׳s capacity, K, for each set size and measured the amplitude of the SAN (sustained anterior negativity, an ERP related to acoustic short-term memory). We correlated their K slopes with their SAN amplitude slopes as a function of set size, and found a significant link between performance and the SAN: a larger increase in SAN amplitude was linked with a larger number of stimuli maintained in ASTM. The SAN decreased in amplitude in the later portion of the silent retention interval, but the correlation between the SAN and capacity remained strong. These results show the SAN is not an index of contour but rather an index of the maintenance of individual objects in STM. This article is part of a Special Issue entitled SI: Auditory working memory. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study

    Science.gov (United States)

    Chen, Yingxuan; Yin, Fang-Fang; Zhang, Yawei; Zhang, You; Ren, Lei

    2018-04-01

    Purpose: compressed sensing reconstruction using total variation (TV) tends to over-smooth the edge information by uniformly penalizing the image gradient. The goal of this study is to develop a novel prior contour based TV (PCTV) method to enhance the edge information in compressed sensing reconstruction for CBCT. Methods: the edge information is extracted from prior planning-CT via edge detection. Prior CT is first registered with on-board CBCT reconstructed with TV method through rigid or deformable registration. The edge contours in prior-CT is then mapped to CBCT and used as the weight map for TV regularization to enhance edge information in CBCT reconstruction. The PCTV method was evaluated using extended-cardiac-torso (XCAT) phantom, physical CatPhan phantom and brain patient data. Results were compared with both TV and edge preserving TV (EPTV) methods which are commonly used for limited projection CBCT reconstruction. Relative error was used to calculate pixel value difference and edge cross correlation was defined as the similarity of edge information between reconstructed images and ground truth in the quantitative evaluation. Results: compared to TV and EPTV, PCTV enhanced the edge information of bone, lung vessels and tumor in XCAT reconstruction and complex bony structures in brain patient CBCT. In XCAT study using 45 half-fan CBCT projections, compared with ground truth, relative errors were 1.5%, 0.7% and 0.3% and edge cross correlations were 0.66, 0.72 and 0.78 for TV, EPTV and PCTV, respectively. PCTV is more robust to the projection number reduction. Edge enhancement was reduced slightly with noisy projections but PCTV was still superior to other methods. PCTV can maintain resolution while reducing the noise in the low mAs CatPhan reconstruction. Low contrast edges were preserved better with PCTV compared with TV and EPTV. Conclusion: PCTV preserved edge information as well as reduced streak artifacts and noise in low dose CBCT reconstruction

  17. Afterimage watercolors: an exploration of contour-based afterimage filling-in.

    Science.gov (United States)

    Hazenberg, Simon J; van Lier, Rob

    2013-01-01

    We investigated filling-in of colored afterimages and compared them with filling-in of "real" colors in the watercolor illusion. We used shapes comprising two thin adjacent undulating outlines of which the inner or the outer outline was chromatic, while the other was achromatic. The outlines could be presented simultaneously, inducing the original watercolor effect, or in an alternating fashion, inducing colored afterimages of the chromatic outlines. In Experiment 1, using only alternating outlines, these afterimages triggered filling-in, revealing an "afterimage watercolor" effect. Depending on whether the inner or the outer outline was chromatic, filling-in of a complementary or a similarly colored afterimage was perceived. In Experiment 2, simultaneous and alternating presentations were compared. Additionally, gray and black achromatic contours were tested, having an increased luminance contrast with the background for the black contours. Compared to "real" color filling-in, afterimage filling-in was more easily affected by different luminance settings. More in particular, afterimage filling-in was diminished when high-contrast contours were used. In the discussion we use additional demonstrations in which we further explore the "watercolor afterimage." All in all, comparisons between both types of illusions show similarities and differences with regard to color filling-in. Caution, however, is warranted in attributing these effects to different underlying processing differences.

  18. Glucagon-like peptide-1 does not have acute effects on central or renal hemodynamics in patients with type 2 diabetes without nephropathy

    DEFF Research Database (Denmark)

    Asmar, Ali; Simonsen, Lene; Asmar, Meena

    2016-01-01

    effects of GLP-1 in patients with type 2 diabetes under fixed sodium intake. During a 3-hour infusion of GLP-1 (1.5 pmol kg(-1) min(-1)) or saline, intra-arterial blood pressure and heart rate were measured continuously, concomitantly with cardiac output estimated by pulse contour analysis. Renal plasma...... infusion, systolic and diastolic blood pressure and cardiac output remained unchanged, whereas heart rate increased significantly. Arterio-venous gradients for GLP-1 exceeded glomerular filtrations significantly, but renal plasma flow and glomerular filtration rate as well as renal sodium and lithium...... flow, glomerular filtration rate, and uptake/release of hormones and ions were measured using Fick's Principle after catheterization of a renal vein. Urine collection was conducted throughout the experiments at voluntary voiding, and patients remained supine during the experiments. During the GLP-1...

  19. Systolic Blood Pressure Accuracy Enhancement in the Electronic Palpation Method Using Pulse Waveform

    Science.gov (United States)

    2001-10-25

    adrenalin) or vasodilating (Nipride or Nitromex) medicines. Also painkillers and anesthetics (Oxanest, Diprivan, Fentanyl and Rapifen) may have affected...the measurements. It is hard to distinguish the effects of medication and assess their relation to blood pressure errors and pulse shapes...CONCLUSION During this study, 51 cardiac operated patients were measured to define the effects of arterial stiffening on the accuracy of the

  20. The influence of radiation therapy on cardiac pacemakers

    International Nuclear Information System (INIS)

    Coles, J.R.; Ciddor, G.S.

    1980-01-01

    The results of an investigation to determine the influence on pacemaking of ionizing radiation and electromagnetic radiation from a number of radiotherapy machines are reported. In vitro tests were carried out on unipolar cardiac pacemakers of the ventricular inhibited type. The pacemakers were largely unaffected by the environment of clinical radiotherapy machines. Ionizing radiation had no detrimental effect on the pacemakers and electromagnetic interference caused only temporary single-beat inhibition at most. With the betatron used, malfunction of the pacemakers regularly occurred whilst in their inhibited made of operation. The demand function became disabled allowing competitive asynchronous pulses to be produced

  1. Mandarin-Speaking Children’s Speech Recognition: Developmental Changes in the Influences of Semantic Context and F0 Contours

    Directory of Open Access Journals (Sweden)

    Hong Zhou

    2017-06-01

    Full Text Available The goal of this developmental speech perception study was to assess whether and how age group modulated the influences of high-level semantic context and low-level fundamental frequency (F0 contours on the recognition of Mandarin speech by elementary and middle-school-aged children in quiet and interference backgrounds. The results revealed different patterns for semantic and F0 information. One the one hand, age group modulated significantly the use of F0 contours, indicating that elementary school children relied more on natural F0 contours than middle school children during Mandarin speech recognition. On the other hand, there was no significant modulation effect of age group on semantic context, indicating that children of both age groups used semantic context to assist speech recognition to a similar extent. Furthermore, the significant modulation effect of age group on the interaction between F0 contours and semantic context revealed that younger children could not make better use of semantic context in recognizing speech with flat F0 contours compared with natural F0 contours, while older children could benefit from semantic context even when natural F0 contours were altered, thus confirming the important role of F0 contours in Mandarin speech recognition by elementary school children. The developmental changes in the effects of high-level semantic and low-level F0 information on speech recognition might reflect the differences in auditory and cognitive resources associated with processing of the two types of information in speech perception.

  2. Posterior belly of digastric muscle flap for contour deformity correction after superficial parotidectomy.

    Science.gov (United States)

    Rai, A; Jain, A; Khan, M

    2017-10-23

    The correction of the contour deformity after parotidectomy has become an essential procedure in the recent times for the betterment of patients' quality of life. Various modalities have been highlighted in the literature for the same. We recommend the use of posterior belly of digastric muscle flap for correction of contour deformity post excision of parotid gland tumors, subsequently ameliorating the aesthetics of the face. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Masculine Chest-Wall Contouring in FtM Transgender: a Personal Approach.

    Science.gov (United States)

    Lo Russo, Giulia; Tanini, Sara; Innocenti, Marco

    2017-04-01

    Chest-wall contouring surgery is one of the first steps in sexual reassignment in female-to-male (FtM) transsexuals that contributes to strengthening of the self-image and facilitates living in the new gender role. The main goal is to masculinize the chest by removing the female contour. Chest contour, scar placement, scar shape, scar length, nipple-areola position, nipple size and the areola size are the key points. Between July 2013 and June 2016, 25 FtM transgender patients underwent surgical procedures to create a masculine chest-wall contour. In our study, we just considered 16 patients who have undergone chest surgery with the double incision method. The patients' survey revealed a high satisfaction rate with the aesthetic result. In our group, no complications occurred, and two patients have undergone supplementary surgery for axillary dog-ear revision and nipple reconstruction. The authors propose a new technical approach and indications for FtM transgender patients' surgery. A longer scar that emphasizes the pectoralis muscle, a smaller nipple and a resized and refaced areola are the key points of our technique to give a masculine appearance to the chest. The scars are permanent, but most of them will fade and the patients are enthusiastic with their new "male" chest appearance. The high level of satisfaction, the great aesthetic result and the low rate of complications suggest to us the use of this technique in medium- and large-size breasts. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. Impact of contour on aesthetic judgments and approach-avoidance decisions in architecture

    Science.gov (United States)

    Vartanian, Oshin; Navarrete, Gorka; Chatterjee, Anjan; Fich, Lars Brorson; Leder, Helmut; Modroño, Cristián; Nadal, Marcos; Rostrup, Nicolai; Skov, Martin

    2013-01-01

    On average, we urban dwellers spend about 90% of our time indoors, and share the intuition that the physical features of the places we live and work in influence how we feel and act. However, there is surprisingly little research on how architecture impacts behavior, much less on how it influences brain function. To begin closing this gap, we conducted a functional magnetic resonance imaging study to examine how systematic variation in contour impacts aesthetic judgments and approach-avoidance decisions, outcome measures of interest to both architects and users of spaces alike. As predicted, participants were more likely to judge spaces as beautiful if they were curvilinear than rectilinear. Neuroanatomically, when contemplating beauty, curvilinear contour activated the anterior cingulate cortex exclusively, a region strongly responsive to the reward properties and emotional salience of objects. Complementing this finding, pleasantness—the valence dimension of the affect circumplex—accounted for nearly 60% of the variance in beauty ratings. Furthermore, activation in a distributed brain network known to underlie the aesthetic evaluation of different types of visual stimuli covaried with beauty ratings. In contrast, contour did not affect approach-avoidance decisions, although curvilinear spaces activated the visual cortex. The results suggest that the well-established effect of contour on aesthetic preference can be extended to architecture. Furthermore, the combination of our behavioral and neural evidence underscores the role of emotion in our preference for curvilinear objects in this domain. PMID:23754408

  5. Cardiac Arrest in Patients Managed for Convulsive Status Epilepticus: Characteristics, Predictors, and Outcome.

    Science.gov (United States)

    Legriel, Stephane; Bresson, Edouard; Deye, Nicolas; Grimaldi, David; Sauneuf, Bertrand; Lesieur, Olivier; Lascarrou, Jean-Baptiste; Argaud, Laurent; Chelly, Jonathan; Beuret, Pascal; Schnell, David; Chateauneuf, Anne-Laure; Holleville, Mathilde; Perier, François; Lemiale, Virginie; Bruel, Cedric; Cronier, Pierrick; Pichon, Nicolas; Mongardon, Nicolas; de-Prost, Nicolas; Dumas, Florence; Cariou, Alain

    2018-05-08

    Cardiac arrest is a catastrophic event that may arise during the management of convulsive status epilepticus. We aimed to report the clinical characteristics, outcomes, and early predictors of convulsive status epilepticus-related cardiac arrest. Retrospective multicenter study. Seventeen university or university affiliated participating ICUs in France and Belgium. Consecutive patients admitted to the participating ICUs for management of successfully resuscitated out-of-hospital cardiac arrest complicating the initial management of convulsive status epilepticus between 2000 and 2015. Patients were compared with controls without cardiac arrest identified in a single-center registry of convulsive status epilepticus patients, regarding characteristics, management, and outcome. None. We included 49 cases with convulsive status epilepticus-cardiac arrest and 235 controls. In the cases, median time from medical team arrival to cardiac arrest was 25 minutes (interquartile range, 5-85 min). First recorded rhythm was asystole in 25 patients (51%) and pulseless electrical activity in 13 patients (27%). A significantly larger proportion of patients had a favorable 1-year outcome (Glasgow Outcome Scale score of 5) among controls (90/235; 38%) than among cases (10/49; 21%; p = 0.02). By multivariate analysis, independent predictors of cardiac arrest were pulse oximetry less than 97% on scene (odds ratio, 2.66; 95% CI, 1.03-7.26; p = 0.04), drug poisoning as the cause of convulsive status epilepticus (odds ratio, 4.13; 95% CI, 1.27-13.53; p = 0.02), and complications during early management (odds ratio, 11.98; 95% CI, 4.67-34.69; p status epilepticus, relative hypoxemia, on-scene management complications, and drug poisoning as the cause of convulsive status epilepticus were strong early predictors of cardiac arrest, suggesting areas for improvement.

  6. Identifying ambiguous prostate gland contours from histology using capsule shape information and least squares curve fitting

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Rania [DigiPen Institute of Technology, Department of Computer Engineering, Redmond, WA (United States); McKenzie, Frederic D. [Old Dominion University, Department of Electrical and Computer Engineering, Norfolk, VA (United States)

    2007-12-15

    To obtain an accurate assessment of the percentage and depth of extra-capsular soft tissue removed with the prostate by the various surgical techniques in order to help surgeons in determining the appropriateness of different surgical approaches. This can be enhanced by an accurate and automated means of identifying the prostate gland contour. To facilitate 3D reconstruction and, ultimately, more accurate analyses, it is essential for us to identify the capsule boundary that separates the prostate gland tissue from its extra-capsular tissue. However, the capsule is sometimes unrecognizable due to the naturally occurring intrusion of muscle and connective tissue into the prostate gland. At these regions where the capsule disappears, its contour can be arbitrarily created with a continuing contour line based on the natural shape of the prostate. We utilize an algorithm based on a least squares curve fitting technique that uses a prostate shape equation to merge previously detected capsule parts with the shape equation to produce an approximated curve that represents the prostate capsule. We have tested our algorithm using three different shapes on 13 histologic prostate slices that are cut at different locations from the apex. The best result shows a 90% average contour match when compared to pathologist-drawn contours. We believe that automatically identifying histologic prostate contours will lead to increased objective analyses of surgical margins and extracapsular spread of cancer. Our results show that this is achievable. (orig.)

  7. Identifying ambiguous prostate gland contours from histology using capsule shape information and least squares curve fitting

    International Nuclear Information System (INIS)

    Hussein, Rania; McKenzie, Frederic D.

    2007-01-01

    To obtain an accurate assessment of the percentage and depth of extra-capsular soft tissue removed with the prostate by the various surgical techniques in order to help surgeons in determining the appropriateness of different surgical approaches. This can be enhanced by an accurate and automated means of identifying the prostate gland contour. To facilitate 3D reconstruction and, ultimately, more accurate analyses, it is essential for us to identify the capsule boundary that separates the prostate gland tissue from its extra-capsular tissue. However, the capsule is sometimes unrecognizable due to the naturally occurring intrusion of muscle and connective tissue into the prostate gland. At these regions where the capsule disappears, its contour can be arbitrarily created with a continuing contour line based on the natural shape of the prostate. We utilize an algorithm based on a least squares curve fitting technique that uses a prostate shape equation to merge previously detected capsule parts with the shape equation to produce an approximated curve that represents the prostate capsule. We have tested our algorithm using three different shapes on 13 histologic prostate slices that are cut at different locations from the apex. The best result shows a 90% average contour match when compared to pathologist-drawn contours. We believe that automatically identifying histologic prostate contours will lead to increased objective analyses of surgical margins and extracapsular spread of cancer. Our results show that this is achievable. (orig.)

  8. Hemispheric lateralization for early auditory processing of lexical tones: dependence on pitch level and pitch contour.

    Science.gov (United States)

    Wang, Xiao-Dong; Wang, Ming; Chen, Lin

    2013-09-01

    In Mandarin Chinese, a tonal language, pitch level and pitch contour are two dimensions of lexical tones according to their acoustic features (i.e., pitch patterns). A change in pitch level features a step change whereas that in pitch contour features a continuous variation in voice pitch. Currently, relatively little is known about the hemispheric lateralization for the processing of each dimension. To address this issue, we made whole-head electrical recordings of mismatch negativity in native Chinese speakers in response to the contrast of Chinese lexical tones in each dimension. We found that pre-attentive auditory processing of pitch level was obviously lateralized to the right hemisphere whereas there is a tendency for that of pitch contour to be lateralized to the left. We also found that the brain responded faster to pitch level than to pitch contour at a pre-attentive stage. These results indicate that the hemispheric lateralization for early auditory processing of lexical tones depends on the pitch level and pitch contour, and suggest an underlying inter-hemispheric interactive mechanism for the processing. © 2013 Elsevier Ltd. All rights reserved.

  9. Segmentation of urinary bladder in CT urography (CTU) using CLASS with enhanced contour conjoint procedure

    Science.gov (United States)

    Cha, Kenny; Hadjiiski, Lubomir; Chan, Heang-Ping; Cohan, Richard H.; Caoili, Elaine M.; Zhou, Chuan

    2014-03-01

    We are developing a computerized method for bladder segmentation in CT urography (CTU) for computeraided diagnosis of bladder cancer. A challenge for computerized bladder segmentation in CTU is that the bladder often contains regions filled with intravenous (IV) contrast and without contrast. Previously, we proposed a Conjoint Level set Analysis and Segmentation System (CLASS) consisting of four stages: preprocessing and initial segmentation, 3D and 2D level set segmentation, and post-processing. In case the bladder is partially filled with contrast, CLASS segments the non-contrast (NC) region and the contrast (C) filled region separately and conjoins the contours with a Contour Conjoint Procedure (CCP). The CCP is not trivial. Inaccuracies in the NC and C contours may cause CCP to exclude portions of the bladder. To alleviate this problem, we implemented model-guided refinement to propagate the C contour if the level set propagation in the region stops prematurely due to substantial non-uniformity of the contrast. An enhanced CCP with regularized energies further propagates the conjoint contours to the correct bladder boundary. Segmentation performance was evaluated using 70 cases. For all cases, 3D hand segmented contours were obtained as reference standard, and computerized segmentation accuracy was evaluated in terms of average volume intersection %, average % volume error, and average minimum distance. With enhanced CCP, those values were 84.4±10.6%, 8.3±16.1%, 3.4±1.8 mm, respectively. With CLASS, those values were 74.6±13.1%, 19.6±18.6%, 4.4±2.2 mm, respectively. The enhanced CCP improved bladder segmentation significantly (p<0.001) for all three performance measures.

  10. Perception of illusory contour figures: Microgenetic analysis

    OpenAIRE

    Gvozdenović Vasilije P.

    2004-01-01

    Microgenetic analysis was used to investigate perception of illusory contour figures which represent whole, completed forms on the basis of segmented, incomplete stimulation. The analysis provided an experimental approach to this phenomenon which was standardly investigated phenomenologically. Experimental procedure consisted of two phases: a) priming phase and b) test phase which consisted of visual search task. Two types of visual search tasks were applied: (i) classic detection, in which s...

  11. Design and development of a new pulsating cardiac coronary phantom for ECG-gated CT and its experimental characteristics

    International Nuclear Information System (INIS)

    Shen, Yun; Sato, Munekuni; Kimura, Fumiko; Jinzaki, Masahiro; Kuribayashi, Sachio; Horiguchi, Jun; Ito, Katsuhide

    2005-01-01

    The optimal pulsating cardiac phantom is an important tool for the evaluation of cardiac images and cardiac applications on electrocardiogram (ECG)-gated multidetector-row CT (MDCT). The purpose of this study was to demonstrate the design and fabrication of the pulsating cardiac coronary phantom. The newly developed pulsating cardiac coronary phantom has the following five key advantages: a driver component that uses only one servomotor to move the phantom in three dimensions (X, Y, and Z directions) with 16 presets of different heart types (heartbeat: 0-120 bpm; ejection fraction: 0-90%); versatile pumping and filling phases to simulate a real heart in a cardiac cycle can be incorporated into the driver sequence including shift of patient heartbeat or irregular pulse (maximum: 200 different heart waves in one scan); a cardiac coronary component constituted of an acrylic/silicon/rubber tube (2-6 mm inner diameter) with stent/in-stent restenosis/stenosis/soft plaque/calcification parts and maximum 16 coronary arteries that can be attached to the phantom in the same scan; the complete phantom can be submerged in a tank to simulate the heart and its surrounding tissues; ECG gating can be from interior trigger and exterior trigger. It has been confirmed that the developed pulsating cardiac phantom is very useful to quantitatively assess imaging of the heart and coronary arteries during phantom experiments. (author)

  12. Limited capacity for contour curvature in iconic memory.

    Science.gov (United States)

    Sakai, Koji

    2006-06-01

    We measured the difference threshold for contour curvature in iconic memory by using the cued discrimination method. The study stimulus consisting of 2 to 6 curved contours was briefly presented in the fovea, followed by two lines as cues. Subjects discriminated the curvature of two cued curves. The cue delays were 0 msec. and 300 msec. in Exps. 1 and 2, respectively, and 50 msec. before the study offset in Exp. 3. Analysis of data from Exps. 1 and 2 showed that the Weber fraction rose monotonically with the increase in set size. Clear set-size effects indicate that iconic memory has a limited capacity. Moreover, clear set-size effect in Exp. 3 indicates that perception itself has a limited capacity. Larger set-size effects in Exp. 1 than in Exp. 3 suggest that iconic memory after perceptual process has limited capacity. These properties of iconic memory at threshold level are contradictory to the traditional view that iconic memory has a high capacity both at suprathreshold and categorical levels.

  13. Attention capture by contour onsets and offsets: no special role for onsets.

    Science.gov (United States)

    Watson, D G; Humphreys, G W

    1995-07-01

    In five experiments, we investigated the power of targets defined by the onset or offset of one of an object's parts (contour onsets and offsets) either to guide or to capture visual attention. In Experiment 1, search for a single contour onset target was compared with search for a single contour offset target against a static background of distractors; no difference was found between the efficiency with which each could be detected. In Experiment 2, onsets and offsets were compared for automatic attention capture, when both occurred simultaneously. Unlike in previous studies, the effects of overall luminance change, new-object creation, and number of onset and offset items were controlled. It was found that contour onset and offset items captured attention equally well. However, display size effects on both target types were also apparent. Such effects may have been due to competition for selection between multiple onset and offset stimuli. In Experiments 3 and 4, single onset and offset stimuli were presented simultaneously and pitted directly against one another among a background of static distractors. In Experiment 3, we examined "guided search," for a target that was formed either from an onset or from an offset among static items. In Experiment 4, the onsets and offsets were uncorrelated with the target location. Similar results occurred in both experiments: target onsets and offsets were detected more efficiently than static stimuli which needed serial search; there remained effects of display size on performance; but there was still no advantage for onsets. In Experiment 5, we examined automatic attention capture by single onset and offset stimuli presented individually among static distractors. Again, there was no advantage for onset over offset targets and a display size effect was also present. These results suggest that, both in isolation and in competition, onsets that do not form new objects neither guide nor gain automatic attention more efficiently

  14. SU-E-J-131: Augmenting Atlas-Based Segmentation by Incorporating Image Features Proximal to the Atlas Contours

    International Nuclear Information System (INIS)

    Li, Dengwang; Liu, Li; Kapp, Daniel S.; Xing, Lei

    2015-01-01

    Purpose: For facilitating the current automatic segmentation, in this work we propose a narrow-shell strategy to enhance the information of each contour in the library and to improve the accuracy of the exiting atlas-based approach. Methods: In setting up an atlas-based library, we include not only the coordinates of contour points, but also the image features adjacent to the contour. 139 planning CT scans with normal appearing livers obtained during their radiotherapy treatment planning were used to construct the library. The CT images within the library were registered each other using affine registration. A nonlinear narrow shell with the regional thickness determined by the distance between two vertices alongside the contour. The narrow shell was automatically constructed both inside and outside of the liver contours. The common image features within narrow shell between a new case and a library case were first selected by a Speed-up Robust Features (SURF) strategy. A deformable registration was then performed using a thin plate splines (TPS) technique. The contour associated with the library case was propagated automatically onto the images of the new patient by exploiting the deformation field vectors. The liver contour was finally obtained by employing level set based energy function within the narrow shell. The performance of the proposed method was evaluated by comparing quantitatively the auto-segmentation results with that delineated by a physician. Results: Application of the technique to 30 liver cases suggested that the technique was capable of reliably segment organs such as the liver with little human intervention. Compared with the manual segmentation results by a physician, the average and discrepancies of the volumetric overlap percentage (VOP) was found to be 92.43%+2.14%. Conclusion: Incorporation of image features into the library contours improves the currently available atlas-based auto-contouring techniques and provides a clinically

  15. SU-E-J-131: Augmenting Atlas-Based Segmentation by Incorporating Image Features Proximal to the Atlas Contours

    Energy Technology Data Exchange (ETDEWEB)

    Li, Dengwang; Liu, Li [College of Physics and Electronics, Shandong Normal University, Jinan, Shandong (China); Kapp, Daniel S.; Xing, Lei [Department of Radiation Oncology, Stanford University, School of Medicine, Stanford, CA (United States)

    2015-06-15

    Purpose: For facilitating the current automatic segmentation, in this work we propose a narrow-shell strategy to enhance the information of each contour in the library and to improve the accuracy of the exiting atlas-based approach. Methods: In setting up an atlas-based library, we include not only the coordinates of contour points, but also the image features adjacent to the contour. 139 planning CT scans with normal appearing livers obtained during their radiotherapy treatment planning were used to construct the library. The CT images within the library were registered each other using affine registration. A nonlinear narrow shell with the regional thickness determined by the distance between two vertices alongside the contour. The narrow shell was automatically constructed both inside and outside of the liver contours. The common image features within narrow shell between a new case and a library case were first selected by a Speed-up Robust Features (SURF) strategy. A deformable registration was then performed using a thin plate splines (TPS) technique. The contour associated with the library case was propagated automatically onto the images of the new patient by exploiting the deformation field vectors. The liver contour was finally obtained by employing level set based energy function within the narrow shell. The performance of the proposed method was evaluated by comparing quantitatively the auto-segmentation results with that delineated by a physician. Results: Application of the technique to 30 liver cases suggested that the technique was capable of reliably segment organs such as the liver with little human intervention. Compared with the manual segmentation results by a physician, the average and discrepancies of the volumetric overlap percentage (VOP) was found to be 92.43%+2.14%. Conclusion: Incorporation of image features into the library contours improves the currently available atlas-based auto-contouring techniques and provides a clinically

  16. Wh-question intonation in Peninsular Spanish: Multiple contours and the effect of task type

    Directory of Open Access Journals (Sweden)

    Nicholas C. Henriksen

    2009-06-01

    Full Text Available This paper reports on an experimental investigation of wh-question intonation in Peninsular Spanish. Speech data were collected from six León, Spain Peninsular Spanish speakers, and oral production data were elicited under two conditions: a computerized sentence reading task and an information gap task-oriented dialogue. The latter task was an adaptation of the HCRC Map Task method (cf. Anderson et al., 1991 and was designed to elicit multiple wh-question productions in an unscripted and more spontaneous speech style than the standard sentence reading task. Results indicate that four contours exist in the tonal inventory of the six speakers. The two most frequent contours were a final rise contour and a nuclear circumflex contour. Systematic task-based differences were found for four of the six speakers, indicating that sentence reading task data alone may not accurately reflect spontaneous speech tonal patterns (cf. Cruttenden, 2007; but see also Lickley, Schepman, & Ladd, 2005. The experimental findings serve to clarify a number of assumptions about the syntax-prosody interface underlying wh-question utterance signaling; they also have implications for research methods in intonation and task-based variation in laboratory phonology.

  17. A combined deep-learning and deformable-model approach to fully automatic segmentation of the left ventricle in cardiac MRI.

    Science.gov (United States)

    Avendi, M R; Kheradvar, Arash; Jafarkhani, Hamid

    2016-05-01

    Segmentation of the left ventricle (LV) from cardiac magnetic resonance imaging (MRI) datasets is an essential step for calculation of clinical indices such as ventricular volume and ejection fraction. In this work, we employ deep learning algorithms combined with deformable models to develop and evaluate a fully automatic LV segmentation tool from short-axis cardiac MRI datasets. The method employs deep learning algorithms to learn the segmentation task from the ground true data. Convolutional networks are employed to automatically detect the LV chamber in MRI dataset. Stacked autoencoders are used to infer the LV shape. The inferred shape is incorporated into deformable models to improve the accuracy and robustness of the segmentation. We validated our method using 45 cardiac MR datasets from the MICCAI 2009 LV segmentation challenge and showed that it outperforms the state-of-the art methods. Excellent agreement with the ground truth was achieved. Validation metrics, percentage of good contours, Dice metric, average perpendicular distance and conformity, were computed as 96.69%, 0.94, 1.81 mm and 0.86, versus those of 79.2-95.62%, 0.87-0.9, 1.76-2.97 mm and 0.67-0.78, obtained by other methods, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Audenaert, Emmanuel; Speleers, Bruno; Vercauteren, Tom; Mulliez, Thomas; Vandemaele, Pieter; Achten, Eric; Kerckaert, Ingrid; D'Herde, Katharina; De Neve, Wilfried; Van Hoof, Tom

    2013-01-01

    Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection

  19. Human body contour data based activity recognition.

    Science.gov (United States)

    Myagmarbayar, Nergui; Yuki, Yoshida; Imamoglu, Nevrez; Gonzalez, Jose; Otake, Mihoko; Yu, Wenwei

    2013-01-01

    This research work is aimed to develop autonomous bio-monitoring mobile robots, which are capable of tracking and measuring patients' motions, recognizing the patients' behavior based on observation data, and providing calling for medical personnel in emergency situations in home environment. The robots to be developed will bring about cost-effective, safe and easier at-home rehabilitation to most motor-function impaired patients (MIPs). In our previous research, a full framework was established towards this research goal. In this research, we aimed at improving the human activity recognition by using contour data of the tracked human subject extracted from the depth images as the signal source, instead of the lower limb joint angle data used in the previous research, which are more likely to be affected by the motion of the robot and human subjects. Several geometric parameters, such as, the ratio of height to weight of the tracked human subject, and distance (pixels) between centroid points of upper and lower parts of human body, were calculated from the contour data, and used as the features for the activity recognition. A Hidden Markov Model (HMM) is employed to classify different human activities from the features. Experimental results showed that the human activity recognition could be achieved with a high correct rate.

  20. The role of non-CRF inhibition in contour detection

    NARCIS (Netherlands)

    Grigorescu, C.; Petkov, N.; Westenberg, M.A.

    2003-01-01

    We propose a biologically motivated computational step, called non-classical receptive field (non-CRF) inhibition, to improve the performance of contour detectors. Non-CRF inhibition is exhibited by 80% of the orientation selective neurons in the primary visual cortex of macaque monkeys and has been

  1. Atomic force microscope observation of branching in single transcript molecules derived from human cardiac muscle

    International Nuclear Information System (INIS)

    Reed, Jason; Hsueh, Carlin; Gimzewski, James K; Mishra, Bud

    2008-01-01

    We have used an atomic force microscope to examine a clinically derived sample of single-molecule gene transcripts, in the form of double-stranded cDNA, (c: complementary) obtained from human cardiac muscle without the use of polymerase chain reaction (PCR) amplification. We observed a log-normal distribution of transcript sizes, with most molecules being in the range of 0.4-7.0 kilobase pairs (kb) or 130-2300 nm in contour length, in accordance with the expected distribution of mRNA (m: messenger) sizes in mammalian cells. We observed novel branching structures not previously known to exist in cDNA, and which could have profound negative effects on traditional analysis of cDNA samples through cloning, PCR and DNA sequencing

  2. Finite Element Analysis of the Effect of Proximal Contour of Class II Composite Restorations on Stress Distribution

    Directory of Open Access Journals (Sweden)

    Hossein Abachizadeh

    2012-09-01

    Full Text Available Introduction: The aim of this study was to evaluate the effect of proximal contour of class II composite restorations placed with straight or contoured matrix band using composite resins with different modulus of elasticity on stress distribution by finite element method. Methods: In order to evaluate the stress distribution of class II composite restorations using finite element method, upper right first molar and second premolar were modeled. Proximal boxes were designed and restored with universal Z250 and packable P60 composite resins (3M ESPE using two matrix systems: flat Tofflemire matrix and precurved sectional matrix. Finally models were evaluated under loads of 200 and 400 Newton at 90 degrees angle and the results were graphically illustrated in the form of Von Misses stresses. Results: In general the stress obtained under 400 Newton load was significantly greater than the stress of models under 200 Newton load. Von Misses stress distribution pattern of two different Z250 and P60 composites were very similar in all modes of loading and proximal contour. In all analyzed models there was a significant difference between models restored with Tofflemire matrix with flat contour and models restored with sectional matrix with curved contour. This difference was greater in first molar than second premolar. Conclusion: Use of a contoured matrix band results in less stress in class II composite resin restorations.

  3. Evaluating the impact of a Canadian national anatomy and radiology contouring boot camp for radiation oncology residents.

    Science.gov (United States)

    Jaswal, Jasbir; D'Souza, Leah; Johnson, Marjorie; Tay, KengYeow; Fung, Kevin; Nichols, Anthony; Landis, Mark; Leung, Eric; Kassam, Zahra; Willmore, Katherine; D'Souza, David; Sexton, Tracy; Palma, David A

    2015-03-15

    Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course ("boot camp") designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, Pradiology in addition to enhancing their confidence and accuracy in contouring. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Spatiotemporal frequency characteristics of cerebral oscillations during the perception of fundamental frequency contour changes in one-syllable intonation.

    Science.gov (United States)

    Ueno, Sanae; Okumura, Eiichi; Remijn, Gerard B; Yoshimura, Yuko; Kikuchi, Mitsuru; Shitamichi, Kiyomi; Nagao, Kikuko; Mochiduki, Masayuki; Haruta, Yasuhiro; Hayashi, Norio; Munesue, Toshio; Tsubokawa, Tsunehisa; Oi, Manabu; Nakatani, Hideo; Higashida, Haruhiro; Minabe, Yoshio

    2012-05-02

    Accurate perception of fundamental frequency (F0) contour changes in the human voice is important for understanding a speaker's intonation, and consequently also his/her attitude. In this study, we investigated the neural processes involved in the perception of F0 contour changes in the Japanese one-syllable interjection "ne" in 21 native-Japanese listeners. A passive oddball paradigm was applied in which "ne" with a high falling F0 contour, used when urging a reaction from the listener, was randomly presented as a rare deviant among a frequent "ne" syllable with a flat F0 contour (i.e., meaningless intonation). We applied an adaptive spatial filtering method to the neuromagnetic time course recorded by whole-head magnetoencephalography (MEG) and estimated the spatiotemporal frequency dynamics of event-related cerebral oscillatory changes in the oddball paradigm. Our results demonstrated a significant elevation of beta band event-related desynchronization (ERD) in the right temporal and frontal areas, in time windows from 100 to 300 and from 300 to 500 ms after the onset of deviant stimuli (high falling F0 contour). This is the first study to reveal detailed spatiotemporal frequency characteristics of cerebral oscillations during the perception of intonational (not lexical) F0 contour changes in the human voice. The results further confirmed that the right hemisphere is associated with perception of intonational F0 contour information in the human voice, especially in early time windows. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Cardiac tamponade: contrast reflux as an indicator of cardiac chamber equalization

    Directory of Open Access Journals (Sweden)

    Nauta Foeke Jacob

    2012-05-01

    Full Text Available Abstract Background Traumatic hemopericardium remains a rare entity; it does however commonly cause cardiac tamponade which remains a major cause of death in traumatic blunt cardiac injury. Objectives We present a case of blunt chest trauma complicated by cardiac tamponade causing cardiac chamber equalization revealed by reflux of contrast. Case report A 29-year-old unidentified male suffered blunt chest trauma in a motor vehicle collision. Computed tomography (CT demonstrated a periaortic hematoma and hemopericardium. Significant contrast reflux was seen in the inferior vena cava and hepatic veins suggesting a change in cardiac chamber pressures. After intensive treatment including cardiac massage this patient expired of cardiac arrest. Conclusion Reflux of contrast on CT imaging can be an indicator of traumatic cardiac tamponade.

  6. Fast Graph Partitioning Active Contours for Image Segmentation Using Histograms

    Directory of Open Access Journals (Sweden)

    Nath SumitK

    2009-01-01

    Full Text Available Abstract We present a method to improve the accuracy and speed, as well as significantly reduce the memory requirements, for the recently proposed Graph Partitioning Active Contours (GPACs algorithm for image segmentation in the work of Sumengen and Manjunath (2006. Instead of computing an approximate but still expensive dissimilarity matrix of quadratic size, , for a 2D image of size and regular image tiles of size , we use fixed length histograms and an intensity-based symmetric-centrosymmetric extensor matrix to jointly compute terms associated with the complete dissimilarity matrix. This computationally efficient reformulation of GPAC using a very small memory footprint offers two distinct advantages over the original implementation. It speeds up convergence of the evolving active contour and seamlessly extends performance of GPAC to multidimensional images.

  7. Living cardiac patch: the elixir for cardiac regeneration.

    Science.gov (United States)

    Lakshmanan, Rajesh; Krishnan, Uma Maheswari; Sethuraman, Swaminathan

    2012-12-01

    A thorough understanding of the cellular and muscle fiber orientation in left ventricular cardiac tissue is of paramount importance for the generation of artificial cardiac patches to treat the ischemic myocardium. The major challenge faced during cardiac patch engineering is to choose a perfect combination of three entities; cells, scaffolds and signaling molecules comprising the tissue engineering triad for repair and regeneration. This review provides an overview of various scaffold materials, their mechanical properties and fabrication methods utilized in cardiac patch engineering. Stem cell therapies in clinical trials and the commercially available cardiac patch materials were summarized in an attempt to provide a recent perspective in the treatment of heart failure. Various tissue engineering strategies employed thus far to construct viable thick cardiac patches is schematically illustrated. Though many strategies have been proposed for fabrication of various cardiac scaffold materials, the stage and severity of the disease condition demands the incorporation of additional cues in a suitable scaffold material. The scaffold may be nanofibrous patch, hydrogel or custom designed films. Integration of stem cells and biomolecular cues along with the scaffold may provide the right microenvironment for the repair of unhealthy left ventricular tissue as well as promote its regeneration.

  8. Quality of life among adults following bariatric and body contouring surgery: a systematic review.

    Science.gov (United States)

    Gilmartin, Jo; Bath-Hextall, Fiona; Maclean, Joan; Stanton, Wendy; Soldin, Mark

    2016-11-01

    Weight loss following bariatric surgery is associated with significant improvements in obesity-related comorbidities, body satisfaction and psychosocial outcomes, at least in the short term. However, in the context of extreme weight loss, body image and appearance may worsen again because the "excess" or "loose" skin can lead to both functional and profound dissatisfaction with appearance. These concerns have led to an increasing uptake of post-bariatric surgery, "body-contouring" procedures but the implications for quality of life (QoL) have not been thoroughly considered. The objective was to identify the best available evidence regarding the QoL outcomes for adults following bariatric and body contouring surgery. The review considered studies involving people aged 18 years and beyond who underwent bariatric surgery and body contouring surgery. The review considered studies that evaluated bariatric surgery as well as body contouring surgery. The review considered both experimental and epidemiological study designs. The primary outcomes were QoL as measured by validated tools at less than two years, two to five years and more than five years following body contouring surgery. The secondary outcomes were adverse events, unsatisfactory aesthetic appearance and weight gain. Six databases were searched, including Cochrane Central, MEDLINE, Embase, Web of Science, PsycINFO and CINAHL. Studies published from 1954 to 2014 were considered. Additional searches for unpublished studies were undertaken in BIOSIS citation index, Register of Current Controlled Trials and Global Health Observatory. The methodological quality of eligible studies was assessed independently by two reviewers using the Joanna Briggs Institute quality assessment tool. Data extraction from the included studies was undertaken and summarized independently by two reviewers using the standardized Joanna Briggs Institute data extraction tool. Studies were too heterogeneous and could not be pooled in

  9. Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

    Energy Technology Data Exchange (ETDEWEB)

    Jaswal, Jasbir [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada); D' Souza, Leah; Johnson, Marjorie [Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, Ontario (Canada); Tay, KengYeow [Department of Diagnostic Radiology, London Health Sciences, London, Ontario (Canada); Fung, Kevin; Nichols, Anthony [Department of Otolaryngology, Head & Neck Surgery, Victoria Hospital, London, Ontario (Canada); Landis, Mark [Department of Diagnostic Radiology, London Health Sciences, London, Ontario (Canada); Leung, Eric [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada); Kassam, Zahra [Department of Diagnostic Radiology, St. Joseph' s Health Care London, London, Ontario (Canada); Willmore, Katherine [Department of Anatomy and Cell Biology, Schulich School of Medicine and Dentistry, Western University, London, Ontario (Canada); D' Souza, David; Sexton, Tracy [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada); Palma, David A., E-mail: david.palma@lhsc.on.ca [Department of Radiation Oncology, London Health Sciences Centre, London, Ontario (Canada)

    2015-03-15

    Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp

  10. Evaluating the Impact of a Canadian National Anatomy and Radiology Contouring Boot Camp for Radiation Oncology Residents

    International Nuclear Information System (INIS)

    Jaswal, Jasbir; D'Souza, Leah; Johnson, Marjorie; Tay, KengYeow; Fung, Kevin; Nichols, Anthony; Landis, Mark; Leung, Eric; Kassam, Zahra; Willmore, Katherine; D'Souza, David; Sexton, Tracy; Palma, David A.

    2015-01-01

    Background: Radiation therapy treatment planning has advanced over the past 2 decades, with increased emphasis on 3-dimensional imaging for target and organ-at-risk (OAR) delineation. Recent studies suggest a need for improved resident instruction in this area. We developed and evaluated an intensive national educational course (“boot camp”) designed to provide dedicated instruction in site-specific anatomy, radiology, and contouring using a multidisciplinary (MDT) approach. Methods: The anatomy and radiology contouring (ARC) boot camp was modeled after prior single-institution pilot studies and a needs-assessment survey. The boot camp incorporated joint lectures from radiation oncologists, anatomists, radiologists, and surgeons, with hands-on contouring instruction and small group interactive seminars using cadaveric prosections and correlative axial radiographs. Outcomes were evaluated using pretesting and posttesting, including anatomy/radiology multiple-choice questions (MCQ), timed contouring sessions (evaluated relative to a gold standard using Dice similarity metrics), and qualitative questions on satisfaction and perceived effectiveness. Analyses of pretest versus posttest scores were performed using nonparametric paired testing. Results: Twenty-nine radiation oncology residents from 10 Canadian universities participated. As part of their current training, 29%, 75%, and 21% receive anatomy, radiology, and contouring instruction, respectively. On posttest scores, the MCQ knowledge scores improved significantly (pretest mean 60% vs posttest mean 80%, P<.001). Across all contoured structures, there was a 0.20 median improvement in students' average Dice score (P<.001). For individual structures, significant Dice improvements occurred in 10 structures. Residents self-reported an improved ability to contour OARs and interpret radiographs in all anatomic sites, 92% of students found the MDT format effective for their learning, and 93% found the boot camp

  11. Making the cut for the contour method

    OpenAIRE

    Bouchard, P. John; Ledgard, Peter; Hiller, Stan; Hosseinzadh Torknezhad, Foroogh

    2012-01-01

    The contour method is becoming an increasingly popular measurement technique for mapping residual stress in engineering components. The accuracy of the technique is critically dependent on the quality of the cut performed. This paper presents results from blind cutting trials on austenitic stainless steel using electro-discharge machines made by three manufacturers. The suitability of the machines is assessed based on the surface finish achieved, risk of wire breakages and the nature of cutti...

  12. Optimizing body contour in massive weight loss patients: the modified vertical abdominoplasty.

    Science.gov (United States)

    Costa, Luiz Fernando da; Landecker, Alan; Manta, Anísio Marinho

    2004-12-01

    In morbid obesity, contour deformities of the abdomen are common after bariatric surgery and radical weight loss. Traditional abdominoplasty techniques often fail to maximally improve body contour in these cases because adjacent sites such as the hip rolls and flanks are not treated, leaving the patient with large lateral tissue redundancies and dog-ears. In an attempt to solve these challenging problems, the authors present the modified vertical abdominoplasty technique, a single-stage procedure that involves a combined vertical and transverse approach in which an "en bloc" resection of the redundant tissues is performed without undermining, drainage, or reinforcement of the abdominal wall. The latter is only carried out when diastasis and/or hernias are present, and Marlex mesh may be utilized when indicated. In patients with simultaneous large umbilical hernias and/or excessively long stalks, neoumbilicoplasty is recommended. A significant improvement of abdominal contour was obtained in the vast majority of patients because the resection design offers simultaneous treatment of both vertical and transverse tissue redundancies in the abdomen and neighboring regions, with more harmonic results when compared with purely vertical or transverse approaches. The modified vertical abdominoplasty technique is an easy, fast, and reliable alternative for treating these patients, with less intraoperative bleeding, reduced overall cost, and low morbidity rates. In selected cases, the technique is capable of offering excellent results in terms of contouring and maximizes the overall outcome of treatment protocols for these patients, who can then be integrated into normal life with heightened self-esteem, happiness, and productivity.

  13. Regulation of cardiac remodeling by cardiac Na/K-ATPase isoforms

    Directory of Open Access Journals (Sweden)

    Lijun Catherine Liu

    2016-09-01

    Full Text Available Cardiac remodeling occurs after cardiac pressure/volume overload or myocardial injury during the development of heart failure and is a determinant of heart failure. Preventing or reversing remodeling is a goal of heart failure therapy. Human cardiomyocyte Na+/K+-ATPase has multiple α isoforms (1-3. The expression of the α subunit of the Na+/K+-ATPase is often altered in hypertrophic and failing hearts. The mechanisms are unclear. There are limited data from human cardiomyocytes. Abundant evidences from rodents show that Na+/K+-ATPase regulates cardiac contractility, cell signaling, hypertrophy and fibrosis. The α1 isoform of the Na+/K+-ATPase is the ubiquitous isoform and possesses both pumping and signaling functions. The α2 isoform of the Na+/K+-ATPase regulates intracellular Ca2+ signaling, contractility and pathological hypertrophy. The α3 isoform of the Na+/K+-ATPase may also be a target for cardiac hypertrophy. Restoration of cardiac Na+/K+-ATPase expression may be an effective approach for prevention of cardiac remodeling. In this article, we will overview: (1 the distribution and function of isoform specific Na+/K+-ATPase in the cardiomyocytes. (2 the role of cardiac Na+/K+-ATPase in the regulation of cell signaling, contractility, cardiac hypertrophy and fibrosis in vitro and in vivo. Selective targeting of cardiac Na+/K+-ATPase isoform may offer a new target for the prevention of cardiac remodeling.

  14. Automatic segmentation of closed-contour features in ophthalmic images using graph theory and dynamic programming

    Science.gov (United States)

    Chiu, Stephanie J.; Toth, Cynthia A.; Bowes Rickman, Catherine; Izatt, Joseph A.; Farsiu, Sina

    2012-01-01

    This paper presents a generalized framework for segmenting closed-contour anatomical and pathological features using graph theory and dynamic programming (GTDP). More specifically, the GTDP method previously developed for quantifying retinal and corneal layer thicknesses is extended to segment objects such as cells and cysts. The presented technique relies on a transform that maps closed-contour features in the Cartesian domain into lines in the quasi-polar domain. The features of interest are then segmented as layers via GTDP. Application of this method to segment closed-contour features in several ophthalmic image types is shown. Quantitative validation experiments for retinal pigmented epithelium cell segmentation in confocal fluorescence microscopy images attests to the accuracy of the presented technique. PMID:22567602

  15. Luminance contours can gate afterimage colors and 'real' colors

    NARCIS (Netherlands)

    Anstis, S.; Vergeer, M.L.T.; Lier, R.J. van

    2012-01-01

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The

  16. Diffusion tensor driven contour closing for cell microinjection targeting.

    Science.gov (United States)

    Becattini, Gabriele; Mattos, Leonardo S; Caldwell, Darwin G

    2010-01-01

    This article introduces a novel approach to robust automatic detection of unstained living cells in bright-field (BF) microscope images with the goal of producing a target list for an automated microinjection system. The overall image analysis process is described and includes: preprocessing, ridge enhancement, image segmentation, shape analysis and injection point definition. The developed algorithm implements a new version of anisotropic contour completion (ACC) based on the partial differential equation (PDE) for heat diffusion which improves the cell segmentation process by elongating the edges only along their tangent direction. The developed ACC algorithm is equivalent to a dilation of the binary edge image with a continuous elliptic structural element that takes into account local orientation of the contours preventing extension towards normal direction. Experiments carried out on real images of 10 to 50 microm CHO-K1 adherent cells show a remarkable reliability in the algorithm along with up to 85% success for cell detection and injection point definition.

  17. Flyby Error Analysis Based on Contour Plots for the Cassini Tour

    Science.gov (United States)

    Stumpf, P. W.; Gist, E. M.; Goodson, T. D.; Hahn, Y.; Wagner, S. V.; Williams, P. N.

    2008-01-01

    The maneuver cancellation analysis consists of cost contour plots employed by the Cassini maneuver team. The plots are two-dimensional linear representations of a larger six-dimensional solution to a multi-maneuver, multi-encounter mission at Saturn. By using contours plotted with the dot product of vectors B and R and the dot product of vectors B and T components, it is possible to view the effects delta V on for various encounter positions in the B-plane. The plot is used in operations to help determine if the Approach Maneuver (ensuing encounter minus three days) and/or the Cleanup Maneuver (ensuing encounter plus three days) can be cancelled and also is a linear check of an integrated solution.

  18. MRI segmentation by active contours model, 3D reconstruction, and visualization

    Science.gov (United States)

    Lopez-Hernandez, Juan M.; Velasquez-Aguilar, J. Guadalupe

    2005-02-01

    The advances in 3D data modelling methods are becoming increasingly popular in the areas of biology, chemistry and medical applications. The Nuclear Magnetic Resonance Imaging (NMRI) technique has progressed at a spectacular rate over the past few years, its uses have been spread over many applications throughout the body in both anatomical and functional investigations. In this paper we present the application of Zernike polynomials for 3D mesh model of the head using the contour acquired of cross-sectional slices by active contour model extraction and we propose the visualization with OpenGL 3D Graphics of the 2D-3D (slice-surface) information for the diagnostic aid in medical applications.

  19. Effects of cigarette smoking on cardiac autonomic function during dynamic exercise.

    Science.gov (United States)

    Mendonca, Goncalo V; Pereira, Fernando D; Fernhall, Bo

    2011-06-01

    The purpose of this study was to investigate the acute effect of cigarette smoking on cardiac autonomic function in young adult smokers during dynamic exercise. Fourteen healthy young smokers (21.4 ± 3.4 years) performed peak and submaximal exercise protocols under control and smoking conditions. Resting and submaximal beat-to-beat R-R series were recorded and spectrally decomposed using the fast Fourier transformation. Smoking resulted in a significant decrease in work time, VO(2peak) and peak O(2) pulse (P exercise after smoking (P smoking, both at rest and during exercise (P smoking (P smoking, but only at rest (P smoking is accompanied by acute changes in heart rate spectral components both at rest and during exercise. Therefore, the cardiac autonomic control is altered by smoking not only at rest, but also during exercise, resulting in reduced vagal modulation and increased sympathetic dominance.

  20. THREE DIMENSIONAL DIGITIZATION OF HUMAN HEAD BY FUSING STRUCTURED LIGHT AND CONTOURS

    Institute of Scientific and Technical Information of China (English)

    Jin Gang; Li Dehua; Hu Hanping; Hu Bing

    2002-01-01

    Three dimensional digitization of human head is desired in many applications. In this paper, an information fusion based scheme is presented to obtain 3-D information of human head. Structured light technology is employed to measure depth. For the special reflection areas,in which the structured light stripe can not be detected directly, the shape of the structured light stripe can be calculated from the corresponding contour. By fusing the information of structured light and the contours, the problem of reflectance influence is solved, and the whole shape of head,including hair area, can be obtained. Some good results are obtained.

  1. Initial Efficacy of a Cardiac Rehabilitation Transition Program: Cardiac TRUST

    Science.gov (United States)

    Zullo, Melissa; Boxer, Rebecca; Moore, Shirley M.

    2012-01-01

    Patients recovering from cardiac events are increasingly using postacute care, such as home health care and skilled nursing facility services. The purpose of this pilot study was to test the initial efficacy, feasibility, and safety of a specially designed postacute care transitional rehabilitation intervention for cardiac patients. Cardiac Transitional Rehabilitation Using Self- Management Techniques (Cardiac TRUST) is a family-focused intervention that includes progressive low-intensity walking and education in self-management skills to facilitate recovery following a cardiac event. Using a randomized two-group design, exercise self-efficacy, steps walked, and participation in an outpatient cardiac rehabilitation program were compared in a sample of 38 older adults; 17 who received the Cardiac TRUST program and 21 who received usual care only. At discharge from postacute care, the intervention group had a trend for higher levels of self-efficacy for exercise outcomes (X=39.1, SD=7.4) than the usual care group (X=34.5; SD=7.0) (t-test 1.9, p=.06). During the 6 weeks following discharge, compared with the usual care group, the intervention group had more attendance in out-patient cardiac rehabilitation (33% compared to 11.8%, F=7.1, p=.03) and a trend toward more steps walked during the first week (X=1,307, SD=652 compared to X=782, SD=544, t-test 1.8, p=.07). The feasibility of the intervention was better for the home health participants than for those in the skilled nursing facility and there were no safety concerns. The provision of cardiac-focused rehabilitation during postacute care has the potential to bridge the gap in transitional services from hospitalization to outpatient cardiac rehabilitation for these patients at high risk for future cardiac events. Further evidence of the efficacy of Cardiac TRUST is warranted. PMID:22084960

  2. Liberation of a pinned spiral wave by a rotating electric pulse

    Science.gov (United States)

    Chen, Jiang-Xing; Peng, Liang; Ma, Jun; Ying, He-Ping

    2014-08-01

    Spiral waves may be pinned to anatomical heterogeneities in the cardiac tissue, which leads to monomorphic ventricular tachycardia. Wave emission from heterogeneities (WEH) induced by electric pulses in one direction (EP) is a promising method for liberating such waves by using heterogeneities as internal virtual pacing sites. Here, based on the WEH effect, a new mechanism of liberation by means of a rotating electric pulse (REP) is proposed in a generic model of excitable media. Compared with the EP, the REP has the advantage of opening wider time window to liberate pinned spiral. The influences of rotating direction and frequency of the REP, and the radius of the obstacles on this new mechanism are studied. We believe this strategy may improve manipulations with pinned spiral waves in heart experiments.

  3. Piezoelectric Lead Zirconate Titanate (PZT) Ring Shaped Contour-Mode MEMS Resonators

    Science.gov (United States)

    Kasambe, P. V.; Asgaonkar, V. V.; Bangera, A. D.; Lokre, A. S.; Rathod, S. S.; Bhoir, D. V.

    2018-02-01

    Flexibility in setting fundamental frequency of resonator independent of its motional resistance is one of the desired criteria in micro-electromechanical (MEMS) resonator design. It is observed that ring-shaped piezoelectric contour-mode MEMS resonators satisfy this design criterion than in case of rectangular plate MEMS resonators. Also ring-shaped contour-mode piezoelectric MEMS resonator has an advantage that its fundamental frequency is defined by in-plane dimensions, but they show variation of fundamental frequency with different Platinum (Pt) thickness referred as change in ratio of fNEW /fO . This paper presents the effects of variation in geometrical parameters and change in piezoelectric material on the resonant frequencies of Platinum piezoelectric-Aluminium ring-shaped contour-mode MEMS resonators and its electrical parameters. The proposed structure with Lead Zirconate Titanate (PZT) as the piezoelectric material was observed to be a piezoelectric material with minimal change in fundamental resonant frequency due to Platinum thickness variation. This structure was also found to exhibit extremely low motional resistance of 0.03 Ω as compared to the 31-35 Ω range obtained when using AlN as the piezoelectric material. CoventorWare 10 is used for the design, simulation and corresponding analysis of resonators which is Finite Element Method (FEM) analysis and design tool for MEMS devices.

  4. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot.

    Science.gov (United States)

    Kim, Ho Jin; Mun, Da Na; Goo, Hyun Woo; Yun, Tae-Jin

    2017-04-01

    Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  5. An aid to two-dimensional contouring using nonuniform orthogonal grids - A Fortran algorithm

    Digital Repository Service at National Institute of Oceanography (India)

    Gouveia, A.D.

    of grids in which Ax and Ay can differ with x and y respectively. Contours obtained in this manner should be used with care if slopes or trends are to be calculated. This algorithm has applications for data presentation in several specialized fields... showing the main features of the variable, care must be taken if the contours are to be used for quantitative estimations of slopes and trends. This procedure, however, avoids the possible errors of injudicious interpolation of the data onto a regular...

  6. An Investigation of Visual Contour Integration Ability in Relation to Writing Performance in Primary School Students

    Science.gov (United States)

    Li-Tsang, Cecilia W. P.; Wong, Agnes S. K.; Chan, Jackson Y.; Lee, Amos Y. T.; Lam, Miko C. Y.; Wong, C. W.; Lu, Zhonglin

    2012-01-01

    A previous study found a visual deficit in contour integration in English readers with dyslexia (Simmers & Bex, 2001). Visual contour integration may play an even more significant role in Chinese handwriting particularly due to its logographic presentation (Lam, Au, Leung, & Li-Tsang, 2011). The current study examined the relationship…

  7. Defining the neural fulcrum for chronic vagus nerve stimulation: implications for integrated cardiac control.

    Science.gov (United States)

    Ardell, Jeffrey L; Nier, Heath; Hammer, Matthew; Southerland, E Marie; Ardell, Christopher L; Beaumont, Eric; KenKnight, Bruce H; Armour, J Andrew

    2017-11-15

    The evoked cardiac response to bipolar cervical vagus nerve stimulation (VNS) reflects a dynamic interaction between afferent mediated decreases in central parasympathetic drive and suppressive effects evoked by direct stimulation of parasympathetic efferent axons to the heart. The neural fulcrum is defined as the operating point, based on frequency-amplitude-pulse width, where a null heart rate response is reproducibly evoked during the on-phase of VNS. Cardiac control, based on the principal of the neural fulcrum, can be elicited from either vagus. Beta-receptor blockade does not alter the tachycardia phase to low intensity VNS, but can increase the bradycardia to higher intensity VNS. While muscarinic cholinergic blockade prevented the VNS-induced bradycardia, clinically relevant doses of ACE inhibitors, beta-blockade and the funny channel blocker ivabradine did not alter the VNS chronotropic response. While there are qualitative differences in VNS heart control between awake and anaesthetized states, the physiological expression of the neural fulcrum is maintained. Vagus nerve stimulation (VNS) is an emerging therapy for treatment of chronic heart failure and remains a standard of therapy in patients with treatment-resistant epilepsy. The objective of this work was to characterize heart rate (HR) responses (HRRs) during the active phase of chronic VNS over a wide range of stimulation parameters in order to define optimal protocols for bidirectional bioelectronic control of the heart. In normal canines, bipolar electrodes were chronically implanted on the cervical vagosympathetic trunk bilaterally with anode cephalad to cathode (n = 8, 'cardiac' configuration) or with electrode positions reversed (n = 8, 'epilepsy' configuration). In awake state, HRRs were determined for each combination of pulse frequency (2-20 Hz), intensity (0-3.5 mA) and pulse widths (130-750 μs) over 14 months. At low intensities and higher frequency VNS, HR increased during the

  8. Gallbladder shape extraction from ultrasound images using active contour models.

    Science.gov (United States)

    Ciecholewski, Marcin; Chochołowicz, Jakub

    2013-12-01

    Gallbladder function is routinely assessed using ultrasonographic (USG) examinations. In clinical practice, doctors very often analyse the gallbladder shape when diagnosing selected disorders, e.g. if there are turns or folds of the gallbladder, so extracting its shape from USG images using supporting software can simplify a diagnosis that is often difficult to make. The paper describes two active contour models: the edge-based model and the region-based model making use of a morphological approach, both designed for extracting the gallbladder shape from USG images. The active contour models were applied to USG images without lesions and to those showing specific disease units, namely, anatomical changes like folds and turns of the gallbladder as well as polyps and gallstones. This paper also presents modifications of the edge-based model, such as the method for removing self-crossings and loops or the method of dampening the inflation force which moves nodes if they approach the edge being determined. The user is also able to add a fragment of the approximated edge beyond which neither active contour model will move if this edge is incomplete in the USG image. The modifications of the edge-based model presented here allow more precise results to be obtained when extracting the shape of the gallbladder from USG images than if the morphological model is used. © 2013 Elsevier Ltd. Published by Elsevier Ltd. All rights reserved.

  9. Orientation-Cue Invariant Population Responses to Contrast-Modulated and Phase-Reversed Contour Stimuli in Macaque V1 and V2

    Science.gov (United States)

    An, Xu; Gong, Hongliang; Yin, Jiapeng; Wang, Xiaochun; Pan, Yanxia; Zhang, Xian; Lu, Yiliang; Yang, Yupeng; Toth, Zoltan; Schiessl, Ingo; McLoughlin, Niall; Wang, Wei

    2014-01-01

    Visual scenes can be readily decomposed into a variety of oriented components, the processing of which is vital for object segregation and recognition. In primate V1 and V2, most neurons have small spatio-temporal receptive fields responding selectively to oriented luminance contours (first order), while only a subgroup of neurons signal non-luminance defined contours (second order). So how is the orientation of second-order contours represented at the population level in macaque V1 and V2? Here we compared the population responses in macaque V1 and V2 to two types of second-order contour stimuli generated either by modulation of contrast or phase reversal with those to first-order contour stimuli. Using intrinsic signal optical imaging, we found that the orientation of second-order contour stimuli was represented invariantly in the orientation columns of both macaque V1 and V2. A physiologically constrained spatio-temporal energy model of V1 and V2 neuronal populations could reproduce all the recorded population responses. These findings suggest that, at the population level, the primate early visual system processes the orientation of second-order contours initially through a linear spatio-temporal filter mechanism. Our results of population responses to different second-order contour stimuli support the idea that the orientation maps in primate V1 and V2 can be described as a spatial-temporal energy map. PMID:25188576

  10. Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude?

    Directory of Open Access Journals (Sweden)

    Gökhan Pekel

    2013-01-01

    Full Text Available Purpose. This study examines the effects of fundus fluorescein angiography (FFA procedure on ocular pulse amplitude (OPA and intraocular pressure (IOP. Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was  mmHg and post-FFA mean OPA value was  mmHg (. Pre-FFA mean IOP value was  mmHg and post-FFA mean IOP value was  mmHg (. Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707.

  11. Long-term stability of contour augmentation in the esthetic zone

    DEFF Research Database (Denmark)

    Jensen, Simon S; Bosshardt, Dieter D; Gruber, Reinhard

    2014-01-01

    , recent data from cone beam computed tomography studies have shown the augmented volume to be stable long-term. However, no human histologic data are available to document the tissue reactions to this bone augmentation procedure. METHODS: Over an 8-year period, 12 biopsies were harvested 14 to 80 months......BACKGROUND: Contour augmentation around early-placed implants (Type 2 placement) using autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) and a collagen barrier membrane has been documented to predictably provide esthetically satisfactory clinical outcomes. In addition...... after implant placement with simultaneous contour augmentation in 10 patients. The biopsies were subjected to histologic and histomorphometric analysis. RESULTS: The biopsies consisted of 32.0% ± 9.6% DBBM particles and 40.6% ± 14.6% mature bone. 70.3% ± 14.5% of the DBBM particle surfaces were covered...

  12. CMOS image sensor with contour enhancement

    Science.gov (United States)

    Meng, Liya; Lai, Xiaofeng; Chen, Kun; Yuan, Xianghui

    2010-10-01

    Imitating the signal acquisition and processing of vertebrate retina, a CMOS image sensor with bionic pre-processing circuit is designed. Integration of signal-process circuit on-chip can reduce the requirement of bandwidth and precision of the subsequent interface circuit, and simplify the design of the computer-vision system. This signal pre-processing circuit consists of adaptive photoreceptor, spatial filtering resistive network and Op-Amp calculation circuit. The adaptive photoreceptor unit with a dynamic range of approximately 100 dB has a good self-adaptability for the transient changes in light intensity instead of intensity level itself. Spatial low-pass filtering resistive network used to mimic the function of horizontal cell, is composed of the horizontal resistor (HRES) circuit and OTA (Operational Transconductance Amplifier) circuit. HRES circuit, imitating dendrite of the neuron cell, comprises of two series MOS transistors operated in weak inversion region. Appending two diode-connected n-channel transistors to a simple transconductance amplifier forms the OTA Op-Amp circuit, which provides stable bias voltage for the gate of MOS transistors in HRES circuit, while serves as an OTA voltage follower to provide input voltage for the network nodes. The Op-Amp calculation circuit with a simple two-stage Op-Amp achieves the image contour enhancing. By adjusting the bias voltage of the resistive network, the smoothing effect can be tuned to change the effect of image's contour enhancement. Simulations of cell circuit and 16×16 2D circuit array are implemented using CSMC 0.5μm DPTM CMOS process.

  13. Safety of holmium laser prostatectomy in patients with cardiac pacemaker implant

    Directory of Open Access Journals (Sweden)

    Narmada P Gupta

    2006-01-01

    Full Text Available Objectives: The use of the standard monopolar electrocautery is associated with significant risks of implant malfunction in patients on a cardiac pacemaker. It is also associated with a risk of adverse cardiac events due to blood loss and fluid absorption. The properties of the holmium laser prevent the occurrence of these adverse events. We report the successful use of this technology in resecting the gland in patients on a permanent cardiac pacemaker implant. MATERIALS AND Methods: Six patients with permanent cardiac pacemaker implant were treated with holmium laser resection of prostate over a period of two years. Treated patients had bothersome prostatic symptoms and failed to respond to medical therapy. All patients were operated under spinal anesthesia using a high power VersaPulse ® PowerSuiteTM Holmium laser source. Normal saline was used as irrigant. Intravesical tissue morcellator was also used to remove the larger fragments in two of the patients. Results : Median patient age was 60 years (range 56-73 and median prostate volume was 40cc (range 20-48cc. None of the patient required blood transfusion or had significant hyponatremia or Transurethral resection syndrome. No patients had any pacemaker malfunction or hemodynamic instability during the procedure or in immediate postoperative period. Improvement in maximum urine flow rate was observed from an average of 7 ml/sec in preoperative period to 22 ml/sec postoperatively at 3 month followup. Conclusions: Holmium laser prostatectomy offers the ideal modality of surgery in patients on a cardiac pacemaker. It helps to avoid additional preparation and minimizes the risk of device malfunction and adverse post operative events.

  14. Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive).

    Science.gov (United States)

    Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry

    2013-11-01

    To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.

  15. Patient-Reported Outcomes in Weight Loss and Body Contouring Surgery

    DEFF Research Database (Denmark)

    Poulsen, Lotte; Klassen, Anne; Rose, Michael

    2017-01-01

    BACKGROUND: Health-related quality of life and satisfaction with appearance are important outcomes in bariatric and body contouring surgery. To investigate these outcomes, scientifically sound and clinically meaningful patient-reported outcome instruments are needed. The authors measured health-r...

  16. Contours, 2ft Contour Information in AutoCAD & ArcInfo formats. AutoCAD contains cut line information. NAD83, Nevada State Plane, West Zone, US Foot. Broken into Township, Range, and Section Grids, Published in 2006, City of Carson City Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Contours dataset current as of 2006. 2ft Contour Information in AutoCAD & ArcInfo formats. AutoCAD contains cut line information. NAD83, Nevada State Plane, West...

  17. TU-H-CAMPUS-JeP1-02: Fully Automatic Verification of Automatically Contoured Normal Tissues in the Head and Neck

    Energy Technology Data Exchange (ETDEWEB)

    McCarroll, R [UT MD Anderson Cancer Center, Houston, TX (United States); UT Health Science Center, Graduate School of Biomedical Sciences, Houston, TX (United States); Beadle, B; Yang, J; Zhang, L; Kisling, K; Balter, P; Stingo, F; Nelson, C; Followill, D; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States); Mejia, M [University of Santo Tomas Hospital, Manila, Metro Manila (Philippines)

    2016-06-15

    Purpose: To investigate and validate the use of an independent deformable-based contouring algorithm for automatic verification of auto-contoured structures in the head and neck towards fully automated treatment planning. Methods: Two independent automatic contouring algorithms [(1) Eclipse’s Smart Segmentation followed by pixel-wise majority voting, (2) an in-house multi-atlas based method] were used to create contours of 6 normal structures of 10 head-and-neck patients. After rating by a radiation oncologist, the higher performing algorithm was selected as the primary contouring method, the other used for automatic verification of the primary. To determine the ability of the verification algorithm to detect incorrect contours, contours from the primary method were shifted from 0.5 to 2cm. Using a logit model the structure-specific minimum detectable shift was identified. The models were then applied to a set of twenty different patients and the sensitivity and specificity of the models verified. Results: Per physician rating, the multi-atlas method (4.8/5 point scale, with 3 rated as generally acceptable for planning purposes) was selected as primary and the Eclipse-based method (3.5/5) for verification. Mean distance to agreement and true positive rate were selected as covariates in an optimized logit model. These models, when applied to a group of twenty different patients, indicated that shifts could be detected at 0.5cm (brain), 0.75cm (mandible, cord), 1cm (brainstem, cochlea), or 1.25cm (parotid), with sensitivity and specificity greater than 0.95. If sensitivity and specificity constraints are reduced to 0.9, detectable shifts of mandible and brainstem were reduced by 0.25cm. These shifts represent additional safety margins which might be considered if auto-contours are used for automatic treatment planning without physician review. Conclusion: Automatically contoured structures can be automatically verified. This fully automated process could be used to

  18. Study fidelity spatial contours of industrial robots

    Directory of Open Access Journals (Sweden)

    A. V. Ivanova

    2014-01-01

    Full Text Available The purpose of this paper to identify deviations fidelity spatial contours of industrial robots, determine the error pattern detected, and define the ways to solve the problem.The paper presents the research results of fidelity spatial contours done by Fanuc M- 710iC/50 industrial robot when moving along a predetermined path. The proposed method uses a QC20-W ballbar wireless system of Renishaw company, designed to diagnose the state of the measurement and playback linear and angular displacements of the CNC.The solutions to adapt the QC20-W ballbar system to the constructive peculiarities of industrial robots with five or more independently controlled axes are given. The stages of the preparation of diagnostic systems and software robot movements are described.According to study results of errors that arise while playing back the programmed motions of a fixed point of robot capture in three mutually perpendicular planes its practical accuracy has been defined when performing movements in a given region of the working area, thereby allowing us, eventually, to draw a conclusion on the possibility to use a robot in one technological process or another.The study has resulted in emerging the guidelines for the operation of industrial robots with five or more independently controlled axes. Using these guidelines enables us to increase the playback accuracy of the industrial robot to 0.01 mm.

  19. Cardiac tumors: optimal cardiac MR sequences and spectrum of imaging appearances.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2012-02-01

    OBJECTIVE: This article reviews the optimal cardiac MRI sequences for and the spectrum of imaging appearances of cardiac tumors. CONCLUSION: Recent technologic advances in cardiac MRI have resulted in the rapid acquisition of images of the heart with high spatial and temporal resolution and excellent myocardial tissue characterization. Cardiac MRI provides optimal assessment of the location, functional characteristics, and soft-tissue features of cardiac tumors, allowing accurate differentiation of benign and malignant lesions.

  20. Design and milling manufacture of polyurethane custom contoured cushions for wheelchair users

    Directory of Open Access Journals (Sweden)

    Wilson Kindlein Junior

    2011-09-01

    Full Text Available BackgroundThe design of custom contoured cushions manufactured inflexible polyurethane foams is an option to improvepositioning and comfort for people with disabilities thatspend most of the day seated in the same position. Thesesurfaces increase the contact area between the seat and theuser. This fact contributes to minimise the local pressuresthat can generate problems like decubitus ulcers. Thepresent research aims at establishing development routesfor custom cushion production to wheelchair users. Thisstudy also contributes to the investigation of ComputerNumerical Control (CNC machining of flexible polyurethanefoams.MethodThe proposed route to obtain the customised seat beganwith acquiring the user’s contour in adequate posturethrough plaster cast. To collect the surface geometry, thecast was three-dimensionally scanned and manipulated inCAD/CAM software. CNC milling parameters such as tools,spindle speeds and feed rates to machine flexiblepolyurethane foams were tested. These parameters wereanalysed regarding the surface quality. The best parameterswere then tested in a customised seat. The possibledimensional changes generated during foam cutting wereanalysed through 3D scanning. Also, the customised seatpressure and temperature distribution was tested.ResultsThe best parameters found for foams with a density of50kg/cm3 were high spindle speeds (24000 rpm and feedrates between 2400–4000mm/min. Those parameters didnot generate significant deformities in the machinedcushions. The custom contoured cushion satisfactorilyincreased the contact area between wheelchair and user, asit distributed pressure and heat evenly.ConclusionThrough this study it was possible to define routes for thedevelopment and manufacturing of customised seats usingdirect CNC milling in flexible polyurethane foams. It alsoshowed that custom contoured cushions efficientlydistribute pressure and temperature, which is believed tominimise tissue lesions such as pressure

  1. Contour tracking and corner detection in a logic programming environment

    DEFF Research Database (Denmark)

    Bell, Benjamin; Pau, L. F.

    1990-01-01

    The added functionality such as contour tracking and corner detection which logic programming lends to standard image operators is described. An environment for implementing low-level imaging operations with Prolog predicates is considered. Within this environment, higher-level image predicates (...

  2. Analysis of Cruising Fuel Conservation Capabilities of Multi-Mode Engine with the Third Contour

    Directory of Open Access Journals (Sweden)

    A. S. Drygin

    2017-01-01

    Full Text Available Based on the analysis results from the patent search and review of domestic and foreign publications in variable cycle engines (VCE was created a classification of the possible schematic diagrams of VCE realizing three-stream engine technologies (the adaptive low pressure compressor (LPC with air extraction behind stages, FLADE compressor, various feeding types of extraction air to the flowing path of the engine, etc..To estimate a three-stream engine application as a part of the power-plant (PP efficiency, was chosen an adaptive LPC technology scheme with the third contour air bypass beyond the critical section of a basic jet nozzle for which a mathematical model (MM of the PP has been created on the basis of one-dimensional MM of the engine. The MM of the PP included 3D modeling results of the air inlet, the LPC with various air extractions to the third contour, and the jet nozzle taking into account the interaction between the basic stream and the third contour stream.The predicted performance of an air inlet have been used to estimate the changes in a total pressure restoration coefficient and an additional resistance coefficient along «a fluid contour» when air extraction is included in the third contour in several cruiser modes of flight.An integrated characteristic of the LPC has been received at various points and levels of air extraction to the third contour, and parameters of extracted air (depending on the point and amount of air extraction, and also on the fan operating mode have been calculated. When analyzing the obtained calculation results, the effect of pressure lines displacement to the right (towards the large reduced rates, growth of efficiency values, and also position displacement of its maximum value to the left (towards the descent reduced rates has been found.To estimate how air extraction of the third contour between the plates of an adjustable supersonic nozzle impacts on its aft deck resistance various parameters of

  3. Automatic segmentation of the right ventricle from cardiac MRI using a learning-based approach.

    Science.gov (United States)

    Avendi, Michael R; Kheradvar, Arash; Jafarkhani, Hamid

    2017-12-01

    This study aims to accurately segment the right ventricle (RV) from cardiac MRI using a fully automatic learning-based method. The proposed method uses deep learning algorithms, i.e., convolutional neural networks and stacked autoencoders, for automatic detection and initial segmentation of the RV chamber. The initial segmentation is then combined with the deformable models to improve the accuracy and robustness of the process. We trained our algorithm using 16 cardiac MRI datasets of the MICCAI 2012 RV Segmentation Challenge database and validated our technique using the rest of the dataset (32 subjects). An average Dice metric of 82.5% along with an average Hausdorff distance of 7.85 mm were achieved for all the studied subjects. Furthermore, a high correlation and level of agreement with the ground truth contours for end-diastolic volume (0.98), end-systolic volume (0.99), and ejection fraction (0.93) were observed. Our results show that deep learning algorithms can be effectively used for automatic segmentation of the RV. Computed quantitative metrics of our method outperformed that of the existing techniques participated in the MICCAI 2012 challenge, as reported by the challenge organizers. Magn Reson Med 78:2439-2448, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus

    Energy Technology Data Exchange (ETDEWEB)

    Yamamura, Jin; Frisch, Michael; Adam, Gerhard; Wedegaertner, Ulrike [University Hospital Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schnackenburg, Bernhard; Kooijmann, Hendrik [Philips Medical Systems, Hamburg (Germany); Hecher, Kurt [University Hospital Hamburg-Eppendorf, Department of Obstetrics and Fetal Medicine, Hamburg (Germany)

    2009-10-15

    The aim of this study was to perform fetal cardiac magnetic resonance imaging (MRI) with triggering of the fetal heart beat in utero in a sheep model. All experimental protocols were reviewed and the usage of ewes and fetuses was approved by the local animal protection authorities. Images of the hearts of six pregnant ewes were obtained by using a 1.5-T MR system (Philips Medical Systems, Best, Netherlands). The fetuses were chronically instrumented with a carotid catheter to measure the fetal heart frequency for the cardiac triggering. Pulse wave triggered, breath-hold cine-MRI with steady-state free precession (SSFP) was achieved in short axis, two-, four- and three-chamber views. The left ventricular volume and thus the function were measured from the short axis. The fetal heart frequencies ranged between 130 and 160 bpm. The mitral, tricuspid, aortic, and pulmonary valves could be clearly observed. The foramen ovale could be visualized. Myocardial contraction was shown in cine sequences. The average blood volume at the end systole was 3.4{+-}0.2 ml ({+-} SD). The average volume at end diastole was 5.2{+-}0.2 ml; thus the stroke volumes of the left ventricle in the systole were between 1.7 and 1.9 ml with ejection fractions of 38.6% and 39%, respectively. The pulse wave triggered cardiac MRI of the fetal heart allowed evaluation of anatomical structures and functional information. This feasibility study demonstrates the applicability of MRI for future evaluation of fetuses with complex congenital heart defects, once a noninvasive method has been developed to perform fetal cardiac triggering. (orig.)

  5. Does atlas-based autosegmentation of neck levels require subsequent manual contour editing to avoid risk of severe target underdosage? A dosimetric analysis

    International Nuclear Information System (INIS)

    Voet, Peter W.J.; Dirkx, Maarten L.P.; Teguh, David N.; Hoogeman, Mischa S.; Levendag, Peter C.; Heijmen, Ben J.M.

    2011-01-01

    Background and purpose: To investigate the dosimetric impact of not editing auto-contours of the elective neck and organs at risk (OAR), generated with atlas-based autosegmentation (ABAS) (Elekta software) for head and neck cancer patients. Materials and methods: For nine patients ABAS auto-contours and auto-contours edited by two observers were available. Based on the non-edited auto-contours clinically acceptable IMRT plans were constructed (designated 'ABAS plans'). These plans were then evaluated for the two edited structure sets, by quantifying the percentage of the neck-PTV receiving more than 95% of the prescribed dose (V 95 ) and the near-minimum dose (D 99 ) in the neck PTV. Dice coefficients and mean contour distances were calculated to quantify the similarity of ABAS auto-contours with the structure sets edited by observer 1 and observer 2. To study the dosimetric importance of editing OAR auto-contours a new IMRT plan was generated for each patient-observer combination, based on the observer's edited CTV and the non-edited salivary gland auto-contours. For each plan mean doses for the non-edited glands were compared with doses for the same glands edited by the observer. Results: For both observers, edited neck CTVs were larger than ABAS auto-contours (p ≤ 0.04), by a mean of 8.7%. When evaluating ABAS plans on the PTVs of the edited structure sets, V 95 reduced by 7.2% ± 5.4% (1 SD) (p 99 was 14.2 Gy (range 1-54 Gy). Even for Dice coefficients >0.8 and mean contour distances 99 up to 11 Gy were observed. For treatment plans based on observer PTVs and non-edited auto-contoured salivary glands, the mean doses in the edited glands differed by only -0.6 Gy ± 1.0 Gy (p = 0.06). Conclusions: Editing of auto-contoured neck CTVs generated by ABAS is required to avoid large underdosages in target volumes. Often used similarity measures for evaluation of auto-contouring algorithms, such as dice coefficients, do not predict well for expected PTV underdose

  6. Cardiac gated ventilation

    International Nuclear Information System (INIS)

    Hanson, C.W. III; Hoffman, E.A.

    1995-01-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. The authors evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50 msec scan aperture. Multi slice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. The authors observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a non-failing model of the heart

  7. Systemic hypertension and non-cardiac surgery.

    Science.gov (United States)

    Misra, Satyajeet

    2017-09-01

    Primary systemic hypertension affects 10%-25% of individuals presenting for surgery and anaesthesia and constitutes an important cause of cancellation of elective surgeries. Much of the fear stems from the fact that hypertension may lead to adverse perioperative outcomes. Although long-standing hypertension increases the risk of stroke, renal dysfunction or major adverse cardiovascular events, the same is usually not seen in the perioperative period if blood pressure is <180/110 mmHg and this has been the overriding theme in the recent guidelines on perioperative blood pressure management. Newer concepts include isolated systolic hypertension and pulse pressure hypertension that are increasingly used to stratify risk. The aim of this review is to focus on the adult patient with chronic primary systemic hypertension posted for elective non-cardiac surgery and outline the perioperative concerns.

  8. Consensus Contouring Guidelines for Postoperative Stereotactic Body Radiation Therapy for Metastatic Solid Tumor Malignancies to the Spine

    International Nuclear Information System (INIS)

    Redmond, Kristin J.; Robertson, Scott; Lo, Simon S.; Soltys, Scott G.; Ryu, Samuel; McNutt, Todd; Chao, Samuel T.; Yamada, Yoshiya; Ghia, Amol; Chang, Eric L.; Sheehan, Jason; Sahgal, Arjun

    2017-01-01

    Purpose: To develop consensus contouring guidelines for postoperative stereotactic body radiation therapy (SBRT) for spinal metastases. Methods and Materials: Ten spine SBRT specialists representing 10 international centers independently contoured the clinical target volume (CTV), planning target volume (PTV), spinal cord, and spinal cord planning organ at risk volume (PRV) for 10 representative clinical scenarios in postoperative spine SBRT for metastatic solid tumor malignancies. Contours were imported into the Computational Environment for Radiotherapy Research. Agreement between physicians was calculated with an expectation minimization algorithm using simultaneous truth and performance level estimation with κ statistics. Target volume definition guidelines were established by finding optimized confidence level consensus contours using histogram agreement analyses. Results: Nine expert radiation oncologists and 1 neurosurgeon completed contours for all 10 cases. The mean sensitivity and specificity were 0.79 (range, 0.71-0.89) and 0.94 (range, 0.90-0.99) for the CTV and 0.79 (range, 0.70-0.95) and 0.92 (range, 0.87-0.99) for the PTV), respectively. Mean κ agreement, which demonstrates the probability that contours agree by chance alone, was 0.58 (range, 0.43-0.70) for CTV and 0.58 (range, 0.37-0.76) for PTV (P<.001 for all cases). Optimized consensus contours were established for all patients with 80% confidence interval. Recommendations for CTV include treatment of the entire preoperative extent of bony and epidural disease, plus immediately adjacent bony anatomic compartments at risk of microscopic disease extension. In particular, a “donut-shaped” CTV was consistently applied in cases of preoperative circumferential epidural extension, regardless of extent of residual epidural extension. Otherwise more conformal anatomic-based CTVs were determined and described. Spinal instrumentation was consistently excluded from the CTV. Conclusions: We provide

  9. Successfully Managing Impending Skin Necrosis following Hyaluronic Acid Filler Injection, using High-Dose Pulsed Hyaluronidase

    Directory of Open Access Journals (Sweden)

    Kwok Thye David Loh, MBBS

    2018-02-01

    Full Text Available Summary:. Facial fillers are becoming increasingly popular as aesthetic procedures to temporarily reduce the depth of wrinkles or to contour faces. However, even in the hands of very experienced injectors, there is always a small possibility of vascular complications like intra-arterial injection of filler substance. We present a case report of a patient who developed features of vascular obstruction in right infraorbital artery and tell-tale signs of impending skin necrosis, after hyaluronic acid filler injection by an experienced injector. The diagnosis of a vascular complication was made quickly with the help of clinical features like blanching, livedo reticularis, and poor capillary refill. Patient was treated promptly with “high-dose pulsed hyaluronidase protocol” comprising three 1,000-unit pulses of hyaluronidase, administered hourly. There was no further increase in size of the involved area after the first dose of hyaluronidase. All of the involved area, along with 1 cm overlapping in uninvolved skin area, was injected during each injection pulse, using a combination of cannula and needle. Complete reperfusion and good capillary filling were achieved after completion of 3 pulses, and these were taken as the end-point of high-dose pulsed hyaluronidase treatment. Immediate skin changes after filler injections, as well as after hyaluronidase injections and during the 3-week recovery period, were documented with photographs and clinical notes. Involved skin was found to have been fully recovered from this vascular episode, thus indicating that complete recovery of the ischemic skin changes secondary to possible intra-arterial injection could be achieved using high-dose pulsed hyaluronidase protocol.

  10. Radiation exposure to the child during cardiac catheterization.

    Science.gov (United States)

    Waldman, J D; Rummerfield, P S; Gilpin, E A; Kirkpatrick, S E

    1981-07-01

    Few data are available regarding radiation exposure to children during cardiac catheterization. Using lithium fluoride thermoluminescent dosimeters, radiation exposure was measured during precatheterization chest roentgenography, fluoroscopy (hemodynamic assessment phase of catheterization) and cineangiography in 30 infants and children, ages 3 days to 21 years. Dosimeters were placed over the eyes, thyroid, anterior chest, posterior chest, anterior abdomen, posterior abdomen and gonads. Average absorbed chest doses were 24.5 mR during chest roentgenography, 5810 mR during catheterization fluoroscopy and 1592 mR during cineangiography. During the complete catheterization, average doses were 26 mR to the eyes, 431 mR to the thyroid area, 150 mR to the abdomen and 11 mR to the gonads. Radiation exposure during pediatric cardiac catheterization is low to the eyes and gonads but high to the chest and thyroid area. To decrease radiation dosage we suggest (1) low pulse-rate fluoroscopy; (2) substitution of contrast echocardiography for cineangiography; (3) large-plate abdominal/gonadal shielding; (4) a selective shield for thyroid area; (5) a very small field during catheter manipulation. Minimum radiation consistent with accurate diagnosis is optimal; however, erroneous or incomplete diagnosis is more dangerous than radiation-related hazards.

  11. Radiation exposure to the child during cardiac catheterization

    International Nuclear Information System (INIS)

    Waldman, J.D.; Rummerfield, P.S.; Gilpin, E.A.; Kirkpatrick, S.E.

    1981-01-01

    Few data are available regarding radiation exposure to children during cardiac catheterization. Using lithium fluoride thermoluminescent dosimeters, radiation exposure was measured during precatheterization chest roentgenography, fluoroscopy (hemodynamic assessment phase of catheterization) and cineangiography in 30 infants and children, ages 3 days to 21 years. Dosimeters were placed over the eyes, thyroid, anterior chest, posterior chest, anterior abdomen, posterior abdomen and gonads. Average absorbed chest doses were 24.5 mR during chest roentgenography, 5810 mR during catheterization fluoroscopy and 1592 mR during cineangiography. During the complete catheterization, average doses were 26 mR to the eyes, 431 mR to the thyroid area, 150 mR to the abdomen and 11 mR to the gonads. Radiation exposure during pediatric cardiac catheterization is low to the eyes and gonads but high to the chest and thyroid area. To decrease radiation dosage we suggest (1) low pulse-rate fluoroscopy; (2) substitution of contrast echocardiography for cineangiography; (3) large-plate abdominal/gonadal shielding; (4) a selective shield for thyroid area; (5) a very small field during catheter manipulation. Minimum radiation consistent with accurate diagnosis is optimal; however, erroneous or incomplete diagnosis is more dangerous than radiation-related hazards

  12. Radiation exposure to the child during cardiac catheterization

    International Nuclear Information System (INIS)

    Waldman, J.D.; Rummerfield, P.S.; Gilpin, E.A.; Kirkpatrick, S.E.

    1981-01-01

    Few data are available regarding radiation exposure to children during cardiac catheterization. Using lithium fluoride thermoluminescent dosimeters, radiation exposure was measured during precatheterization chest roentgenography, fluoroscopy hemodynamic assessment phase of catheterization and cineangiography in 30 infants and children, ages 3 days to 21 years. Dosimeters were placed over the eyes, thyroid, anterior chest, posterior chest, anterior abdomen, posterior abdomen and gonads. Average absorbed chest doses were 24.5 mR during chest roentgenography, 5810 mR during catheterization fluoroscopy and 1592 mR during cineangiography. During the complete catheterization, average doses were 26 mR to the eyes, 431 mR to the thyroid area, 150 mR to the abdomen and 11 mR to the gonads. Radiation exposure during pediatric cardiac catheterization is low to the eyes and gonads but high to the chest and thyroid area. To decrease radiation dosage we suggest: (1) low pulse-rate fluoroscopy; (2) substitution of contrast echocardiography for cineangiography; (3) large-plate abdominal/gonadal shielding; (4) a selective shield for thyroid area; (5) a very small field during catheter manipulation. Minimum radiation consistent with accurate diagnosis is optimal; however, erroneous or incomplete diagnosis is more dangerous than radiation-related hazards

  13. Cardiac function and cognition in older community-dwelling cardiac patients.

    Science.gov (United States)

    Eggermont, Laura H P; Aly, Mohamed F A; Vuijk, Pieter J; de Boer, Karin; Kamp, Otto; van Rossum, Albert C; Scherder, Erik J A

    2017-11-01

    Cognitive deficits have been reported in older cardiac patients. An underlying mechanism for these findings may be reduced cardiac function. The relationship between cardiac function as represented by different echocardiographic measures and different cognitive function domains in older cardiac patients remains unknown. An older (≥70 years) heterogeneous group of 117 community-dwelling cardiac patients under medical supervision by a cardiologist underwent thorough echocardiographic assessment including left ventricular ejection fraction, cardiac index, left atrial volume index, left ventricular mass index, left ventricular diastolic function, and valvular calcification. During a home visit, a neuropsychological assessment was performed within 7.1 ± 3.8 months after echocardiographic assessment; the neuropsychological assessment included three subtests of a word-learning test (encoding, recall, recognition) to examine one memory function domain and three executive function tests, including digit span backwards, Trail Making Test B minus A, and the Stroop colour-word test. Regression analyses showed no significant linear or quadratic associations between any of the echocardiographic functions and the cognitive function measures. None of the echocardiographic measures as representative of cardiac function was correlated with memory or executive function in this group of community-dwelling older cardiac patients. These findings contrast with those of previous studies. © 2017 Japanese Psychogeriatric Society.

  14. Image-based historical manuscript dating using contour and stroke fragments

    NARCIS (Netherlands)

    He, Sheng; Samara, Petros; Burgers, Jan; Schomaker, Lambertus

    2016-01-01

    Historical manuscript dating has always been an important challenge for historians but since countless manuscripts have become digitally available recently, the pattern recognition community has started addressing the dating problem as well. In this paper, we present a family of local contour

  15. Implicit Active Contours Driven by Local and Global Image Fitting Energy for Image Segmentation and Target Localization

    Directory of Open Access Journals (Sweden)

    Xiaosheng Yu

    2013-01-01

    Full Text Available We propose a novel active contour model in a variational level set formulation for image segmentation and target localization. We combine a local image fitting term and a global image fitting term to drive the contour evolution. Our model can efficiently segment the images with intensity inhomogeneity with the contour starting anywhere in the image. In its numerical implementation, an efficient numerical schema is used to ensure sufficient numerical accuracy. We validated its effectiveness in numerous synthetic images and real images, and the promising experimental results show its advantages in terms of accuracy, efficiency, and robustness.

  16. Cardiac function and cognition in older community-dwelling cardiac patients

    NARCIS (Netherlands)

    Eggermont, Laura H.P.; Aly, Mohamed F.A.; Vuijk, Pieter J.; de Boer, Karin; Kamp, Otto; van Rossum, Albert C.; Scherder, Erik J.A.

    2017-01-01

    Background: Cognitive deficits have been reported in older cardiac patients. An underlying mechanism for these findings may be reduced cardiac function. The relationship between cardiac function as represented by different echocardiographic measures and different cognitive function domains in older

  17. The effect of betel nut chewing on contour and object masking.

    Science.gov (United States)

    Ho, Ming-Chou; Wang, Chin-Kun

    2011-11-01

    The betel nut is a common stimulant in many Asian countries. We employed the masking task developed by Enns and Di Lollo (Trends in Cognitive Sciences, 4, 345-352, 1997) to investigate the effects of betel nuts on sensory and attentional processing. In the masking task, participants needed to identify a target that was masked by either a contour mask or an object mask. Sensory processing was assessed by examining target identification in the contour mask condition when the target was presented only centrally, whereas attentional processing was assessed by examining target identification in the object mask condition when the target was presented randomly in either a central or a parafoveal location. The results showed that chewing betel nut and chewing gum produced significant contour masking with a large effect size, similar to the pure control condition, in which participants chewed nothing, and the placebo control condition, in which what participants chewed was disguised. This suggests that neither betel nut nor gum affects sensory processing. Alternatively, betel nut chewing could produce a reduction in object masking for the habitual chewers and the nonchewers, suggesting an effect of betel nut on attentional processing. This concentrated attention was also observed in the placebo control condition; thus, it cannot be exclusively driven by the expectation effect. Also, chewing per se reduced the attentional distribution foveally.

  18. Performance benchmarking in cardiac imaging

    International Nuclear Information System (INIS)

    Schick, D.; Thiele, D.

    2004-01-01

    Full text: Diagnostic and interventional procedures performed in a cardiac catheter laboratory while demanding high image quality may also result in high patient radiation dose depending on the length or complexity of the procedure. Clinicians using the X-ray equipment require confidence that the system is operating optimally to ensure maximum benefit to the patient with minimum risk. 17 cardiac catheterisation laboratories have been surveyed using a phantom based on the NEMA XR 21 -2000 standard. The testing protocol measures spatial resolution, low contrast detectability, patient dose rate, dynamic range and motion blur for modes of operation and simulated patient sizes applicable to a diagnostic left heart catheter study. The combined results of the assessed laboratories are presented. The latest generation systems with flat-panel detectors exhibit better spatial resolution than older systems with image intensifiers. Phantom measurements show up to a 6 fold variation in dose rate across the range of systems assessed for a given patient size. As expected, some correlation between patient dose rate and the low contrast detectability score is evident. The extent of temporal filtering and pulse width is reflected in the motion blur score. The dynamic range measurements are found to be a less sensitive measure in evaluating system performance. Examination of patient dose results in the context of low contrast detectability score indicates that dose reduction could be achieved without compromising diagnosis on some systems. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  19. Understanding Physiological and Degenerative Natural Vision Mechanisms to Define Contrast and Contour Operators

    Science.gov (United States)

    Demongeot, Jacques; Fouquet, Yannick; Tayyab, Muhammad; Vuillerme, Nicolas

    2009-01-01

    Background Dynamical systems like neural networks based on lateral inhibition have a large field of applications in image processing, robotics and morphogenesis modeling. In this paper, we will propose some examples of dynamical flows used in image contrasting and contouring. Methodology First we present the physiological basis of the retina function by showing the role of the lateral inhibition in the optical illusions and pathologic processes generation. Then, based on these biological considerations about the real vision mechanisms, we study an enhancement method for contrasting medical images, using either a discrete neural network approach, or its continuous version, i.e. a non-isotropic diffusion reaction partial differential system. Following this, we introduce other continuous operators based on similar biomimetic approaches: a chemotactic contrasting method, a viability contouring algorithm and an attentional focus operator. Then, we introduce the new notion of mixed potential Hamiltonian flows; we compare it with the watershed method and we use it for contouring. Conclusions We conclude by showing the utility of these biomimetic methods with some examples of application in medical imaging and computed assisted surgery. PMID:19547712

  20. Understanding physiological and degenerative natural vision mechanisms to define contrast and contour operators.

    Directory of Open Access Journals (Sweden)

    Jacques Demongeot

    Full Text Available BACKGROUND: Dynamical systems like neural networks based on lateral inhibition have a large field of applications in image processing, robotics and morphogenesis modeling. In this paper, we will propose some examples of dynamical flows used in image contrasting and contouring. METHODOLOGY: First we present the physiological basis of the retina function by showing the role of the lateral inhibition in the optical illusions and pathologic processes generation. Then, based on these biological considerations about the real vision mechanisms, we study an enhancement method for contrasting medical images, using either a discrete neural network approach, or its continuous version, i.e. a non-isotropic diffusion reaction partial differential system. Following this, we introduce other continuous operators based on similar biomimetic approaches: a chemotactic contrasting method, a viability contouring algorithm and an attentional focus operator. Then, we introduce the new notion of mixed potential Hamiltonian flows; we compare it with the watershed method and we use it for contouring. CONCLUSIONS: We conclude by showing the utility of these biomimetic methods with some examples of application in medical imaging and computed assisted surgery.

  1. Curvature Analysis of Cardiac Excitation Wavefronts

    Science.gov (United States)

    2013-04-01

    reconstructed the isolines of 10,000 frames, both with PIRA and the contour function of MATLAB. The first took 1.65 seconds while the second took 720...seconds. Hence, PIRA had a 444.44-fold speedup compared to contour. The platform was equipped with Intel Core i7-930 2.8 GHz LGA 1,366 130W Quad-Core

  2. SU-F-J-161: Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Elzibak, A; Loblaw, A; Morton, G; Vesprini, D; Liu, S; Chung, H; Davidson, M [Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada)

    2016-06-15

    Purpose: To investigate the usefulness of metal artifact reduction in CT images of patients with bilateral hip prostheses (BHP) for contouring the prostate and determine if the inclusion of MR images provides additional benefits. Methods: Five patients with BHP were CT scanned using our clinical protocol (140kV, 300mAs, 3mm slices, 1.5mm increment, Philips Medical Systems, OH). Images were reconstructed with the orthopaedic metal artifact reduction (O-MAR) algorithm. MRI scanning was then performed (1.5T, GE Healthcare, WI) with a flat table-top (T{sub 2}-weighted, inherent body coil, FRFSE, 3mm slices with 0mm gap). All images were transferred to Pinnacle (Version 9.2, Philips Medical Systems). For each patient, two data sets were produced: one containing the O-MAR-corrected CT images and another containing fused MRI and O-MAR-corrected CT images. Four genito-urinary radiation oncologists contoured the prostate of each patient on the O-MAR-corrected CT data. Two weeks later, they contoured the prostate on the fused data set, blinded to all other contours. During each contouring session, the oncologists reported their confidence in the contours (1=very confident, 3=not confident) and the contouring difficulty that they experienced (1=really easy, 4=very challenging). Prostate volumes were computed from the contours and the conformity index was used to evaluate inter-observer variability. Results: Larger prostate volumes were found on the O-MAR-corrected CT set than on the fused set (p< 0.05, median=36.9cm{sup 3} vs. 26.63 cm{sup 3}). No significant differences were noted in the inter-observer variability between the two data sets (p=0.3). Contouring difficulty decreased with the addition of MRI (p<0.05) while the radiation oncologists reported more confidence in their contours when MRI was fused with the O-MAR-corrected CT data (p<0.05). Conclusion: This preliminary work demonstrated that, while O-MAR correction to CT images improves visualization of anatomy, the

  3. Effects of Semantic Context and Fundamental Frequency Contours on Mandarin Speech Recognition by Second Language Learners.

    Science.gov (United States)

    Zhang, Linjun; Li, Yu; Wu, Han; Li, Xin; Shu, Hua; Zhang, Yang; Li, Ping

    2016-01-01

    Speech recognition by second language (L2) learners in optimal and suboptimal conditions has been examined extensively with English as the target language in most previous studies. This study extended existing experimental protocols (Wang et al., 2013) to investigate Mandarin speech recognition by Japanese learners of Mandarin at two different levels (elementary vs. intermediate) of proficiency. The overall results showed that in addition to L2 proficiency, semantic context, F0 contours, and listening condition all affected the recognition performance on the Mandarin sentences. However, the effects of semantic context and F0 contours on L2 speech recognition diverged to some extent. Specifically, there was significant modulation effect of listening condition on semantic context, indicating that L2 learners made use of semantic context less efficiently in the interfering background than in quiet. In contrast, no significant modulation effect of listening condition on F0 contours was found. Furthermore, there was significant interaction between semantic context and F0 contours, indicating that semantic context becomes more important for L2 speech recognition when F0 information is degraded. None of these effects were found to be modulated by L2 proficiency. The discrepancy in the effects of semantic context and F0 contours on L2 speech recognition in the interfering background might be related to differences in processing capacities required by the two types of information in adverse listening conditions.

  4. Body contour measurements by conoscopy: application in nuclear medicine, study of feasibility

    International Nuclear Information System (INIS)

    Scheiber, C.; Musse, O.; Mallet, Y.; Sirat, G.

    1997-01-01

    The aim of this study was to obtain a precise mapping of the human body contours as viewed by the gamma camera during acquisition for pathological focus detection and as intermediary in the fusion with morphological images sources (CT, IRM, US). The measurement of the human body contours, making use of a telemeter system, was proposed by O. Peria (Ph.D Thesis, University of Grenoble) by using a laser telemeter and then structured-light sources. We proposed utilization of a non-coherent interferometer, the conoscope developed by G. Sirat, coupled to an electro-mechanical sweeping system mounted on the gamma camera rack. The first tests realized with a slow prototype (3 pt/s), have allowed the recording of visage contours (a profile obtained by angular rotation of the camera (10 deg.) on an (Elscint, Haifa) Helix gamma camera). For this experiment the voluntary subject has worn protection spectacles (the light source being a laser of 1 mW). Among the advantages of this compact system (14 x 10 x 15 cm) we stress: a) a high precision (0.2 mm); b) being installed on the rack, the calibration procedures are simplified and their shifts are potentially reduced; c) the procedures of intra-modality image matching is simplified; d) an integrated fast electronic circuitry (DSP) allows to exploit directly, in real time if necessary, the obtained results (x,y,z coordinates of the studied point). We considered that by its precision, its insensitivity to luminous environment conditions and its integration with the turning gamma camera, the system deserves to be evaluated for application in medical imaging. This system as other intermediate captors, using body contours, allows the superimposing of data, other than the image data, what helps the stereotaxic localization

  5. Design and milling manufacture of polyurethane custom contoured cushions for wheelchair users.

    Science.gov (United States)

    da Silva, Fabio Pinto; Beretta, Elisa Marangon; Prestes, Rafael Cavalli; Kindlein Junior, Wilson

    2011-01-01

    The design of custom contoured cushions manufactured in flexible polyurethane foams is an option to improve positioning and comfort for people with disabilities that spend most of the day seated in the same position. These surfaces increase the contact area between the seat and the user. This fact contributes to minimise the local pressures that can generate problems like decubitus ulcers. The present research aims at establishing development routes for custom cushion production to wheelchair users. This study also contributes to the investigation of Computer Numerical Control (CNC) machining of flexible polyurethane foams. The proposed route to obtain the customised seat began with acquiring the user's contour in adequate posture through plaster cast. To collect the surface geometry, the cast was three-dimensionally scanned and manipulated in CAD/CAM software. CNC milling parameters such as tools, spindle speeds and feed rates to machine flexible polyurethane foams were tested. These parameters were analysed regarding the surface quality. The best parameters were then tested in a customised seat. The possible dimensional changes generated during foam cutting were analysed through 3D scanning. Also, the customised seat pressure and temperature distribution was tested. The best parameters found for foams with a density of 50kg/cm(3) were high spindle speeds (24000 rpm) and feed rates between 2400-4000mm/min. Those parameters did not generate significant deformities in the machined cushions. The custom contoured cushion satisfactorily increased the contact area between wheelchair and user, as it distributed pressure and heat evenly. Through this study it was possible to define routes for the development and manufacturing of customised seats using direct CNC milling in flexible polyurethane foams. It also showed that custom contoured cushions efficiently distribute pressure and temperature, which is believed to minimise tissue lesions such as pressure ulcers.

  6. Synchronous activity in cat visual cortex encodes collinear and cocircular contours.

    Science.gov (United States)

    Samonds, Jason M; Zhou, Zhiyi; Bernard, Melanie R; Bonds, A B

    2006-04-01

    We explored how contour information in primary visual cortex might be embedded in the simultaneous activity of multiple cells recorded with a 100-electrode array. Synchronous activity in cat visual cortex was more selective and predictable in discriminating between drifting grating and concentric ring stimuli than changes in firing rate. Synchrony was found even between cells with wholly different orientation preferences when their receptive fields were circularly aligned, and membership in synchronous groups was orientation and curvature dependent. The existence of synchrony between cocircular cells reinforces its role as a general mechanism for contour integration and shape detection as predicted by association field concepts. Our data suggest that cortical synchrony results from common and synchronous input from earlier visual areas and that it could serve to shape extrastriate response selectivity.

  7. Detection of elliptical contours

    International Nuclear Information System (INIS)

    Blokland, J.A.K.

    1987-01-01

    This dissertation describes the quantitation of myocardial perfusion defects in planar thallium-201 scintigrams. To be able to quantify the distribution of 201 Tl in the myocardium as imaged by the scintigram, accurate delineation of the target object is a prerequisite. The distribution of the radionuclide within the contour of the left ventricle can be described by application of circumferential profiles. By comparing the computed circumferential profile with those of normal subjects, humans with no evidence of coronary artery disease, segments of the left ventricle with decreased bloodflow can be detected. In practice there is no real standard to compare with, and due to noise and biological variations, it is not always possible to make a definite decision regarding the presence of a defect in the distribution of the radionuclide. The value and limitations of the developed quantification procedure are discussed. Some future developments are suggested. 108 refs.; 57 figs.; 5 tabs

  8. The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators

    International Nuclear Information System (INIS)

    Venselaar, J.L.M.

    1985-01-01

    Eight cardiac pacemakers were irradiated in a cobalt-60 beam. Two out of six demand-type pacemakers showed an alarming decrease in pulse repetition frequency when irradiated to dose levels that are used in radiotherapy. Two modern programmable pacemakers showed a failure at a dose of 97 and 147 Gy, respectively. The dose levels at which these failures occurred were low enough to recommend that cardiac pacemakers should always be kept outside the radiation beam. The signals induced by electromagnetic interference (EMI) from two linear accelerators were measured using a simulation model of a pacemaker. In the laboratory, 22 modern-type pacemakers were tested with these signals to determine the sensitivity for the electromagnetic fields in the treatment rooms. It was observed that an inhibition of one pacemaker pulse was to be expected on one of the two linear accelerators when switching the machine on and off. No permanent effects were found. These findings resulted in the recommendation in our department not to use this treatment machine for radiation therapy of pacemaker-bearing patients. (orig.)

  9. Creation of RTOG compliant patient CT-atlases for automated atlas based contouring of local regional breast and high-risk prostate cancers.

    Science.gov (United States)

    Velker, Vikram M; Rodrigues, George B; Dinniwell, Robert; Hwee, Jeremiah; Louie, Alexander V

    2013-07-25

    Increasing use of IMRT to treat breast and prostate cancers at high risk of regional nodal spread relies on accurate contouring of targets and organs at risk, which is subject to significant inter- and intra-observer variability. This study sought to evaluate the performance of an atlas based deformable registration algorithm to create multi-patient CT based atlases for automated contouring. Breast and prostate multi-patient CT atlases (n = 50 and 14 respectively) were constructed to be consistent with RTOG consensus contouring guidelines. A commercially available software algorithm was evaluated by comparison of atlas-predicted contours against manual contours using Dice Similarity coefficients. High levels of agreement were demonstrated for prediction of OAR contours of lungs, heart, femurs, and minor editing required for the CTV breast/chest wall. CTVs generated for axillary nodes, supraclavicular nodes, prostate, and pelvic nodes demonstrated modest agreement. Small and highly variable structures, such as internal mammary nodes, lumpectomy cavity, rectum, penile bulb, and seminal vesicles had poor agreement. A method to construct and validate performance of CT-based multi-patient atlases for automated atlas based auto-contouring has been demonstrated, and can be adopted for clinical use in planning of local regional breast and high-risk prostate radiotherapy.

  10. Creation of RTOG compliant patient CT-atlases for automated atlas based contouring of local regional breast and high-risk prostate cancers

    International Nuclear Information System (INIS)

    Velker, Vikram M; Rodrigues, George B; Dinniwell, Robert; Hwee, Jeremiah; Louie, Alexander V

    2013-01-01

    Increasing use of IMRT to treat breast and prostate cancers at high risk of regional nodal spread relies on accurate contouring of targets and organs at risk, which is subject to significant inter- and intra-observer variability. This study sought to evaluate the performance of an atlas based deformable registration algorithm to create multi-patient CT based atlases for automated contouring. Breast and prostate multi-patient CT atlases (n = 50 and 14 respectively) were constructed to be consistent with RTOG consensus contouring guidelines. A commercially available software algorithm was evaluated by comparison of atlas-predicted contours against manual contours using Dice Similarity coefficients. High levels of agreement were demonstrated for prediction of OAR contours of lungs, heart, femurs, and minor editing required for the CTV breast/chest wall. CTVs generated for axillary nodes, supraclavicular nodes, prostate, and pelvic nodes demonstrated modest agreement. Small and highly variable structures, such as internal mammary nodes, lumpectomy cavity, rectum, penile bulb, and seminal vesicles had poor agreement. A method to construct and validate performance of CT-based multi-patient atlases for automated atlas based auto-contouring has been demonstrated, and can be adopted for clinical use in planning of local regional breast and high-risk prostate radiotherapy

  11. Comparison of surface contour and volumetric three-dimensional imaging of the musculoskeletal system

    International Nuclear Information System (INIS)

    Guilford, W.B.; Ullrich, C.G.; Moore, T.

    1988-01-01

    Both surface contour and volumetric three-dimensional image processing from CT data can provide accurate demonstration of skeletal anatomy. While realistic, surface contour images may obscure fine detail such as nondisplaced fractures, and thin bone may disappear. Volumetric processing can provide high detail, but the transparency effect is unnatural and may yield a confusing image. Comparison of both three-dimensional modes is presented to demonstrate those findings best shown with each and to illustrate helpful techniques to improve volumetric display, such as disarticulation of unnecessary anatomy, short-angle repeating rotation (dithering), and image combination into overlay displays

  12. Fermi surface contours obtained from scanning tunneling microscope images around surface point defects

    International Nuclear Information System (INIS)

    Khotkevych-Sanina, N V; Kolesnichenko, Yu A; Van Ruitenbeek, J M

    2013-01-01

    We present a theoretical analysis of the standing wave patterns in scanning tunneling microscope (STM) images, which occur around surface point defects. We consider arbitrary dispersion relations for the surface states and calculate the conductance for a system containing a small-size tunnel contact and a surface impurity. We find rigorous theoretical relations between the interference patterns in the real-space STM images, their Fourier transforms and the Fermi contours of two-dimensional electrons. We propose a new method for reconstructing Fermi contours of surface electron states, directly from the real-space STM images around isolated surface defects. (paper)

  13. Depth Contours for select locations across the U.S. Pacific Islands

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data are depth contours (isobaths) derived at 50 meters for most islands and reefs in the Mariana Archipelago, American Samoa, and the Pacific Remote Island...

  14. Body contouring following massive weight loss

    Directory of Open Access Journals (Sweden)

    Vijay Langer

    2011-01-01

    Full Text Available Obesity is a global disease with epidemic proportions. Bariatric surgery or modified lifestyles go a long way in mitigating the vast weight gain. Patients following these interventions usually undergo massive weight loss. This results in redundant tissues in various parts of the body. Loose skin causes increased morbidity and psychological trauma. This demands various body contouring procedures that are usually excisional. These procedures are complex and part of a painstaking process that needs a committed patient and an industrious plastic surgeon. As complications in these patients can be quite frequent, both the patient and the surgeon need to be aware and willing to deal with them.

  15. The role of remote closure in the perception of occlusion at junctions and illusory contours.

    Science.gov (United States)

    Gillam, Barbara J; Grove, Philip M; Layden, Jessica

    2010-01-01

    Abstract. Perceived occlusion at T-junctions or illusory contours at implicit T-junctions are often modelled by using edge information without surface context. We explored the effect of closure on perceived occlusion at T-junctions. Two vertical lines separated by a gap each had six abutting horizontal lines on opposite sides forming T-junctions. These lines were either closed or not closed into pairs at the stem ends of the Ts. In experiment 1, closed T-junction stems gave a much stronger sense of occlusion at the vertical lines than unclosed ones, even though closure information was remote from the putative occlusion and local T-junction information remained constant. When the outer two T-junctions were converted to L-junctions, perceived occlusion considerably diminished. The effect of closure on illusory-contour strength for stimuli like those of experiment 1 but with the vertical lines omitted was explored in experiment 2. The two sets of horizontal lines, separated by a gap, were either closed or not closed into pairs at their outer ends. Illusory-contour strength along the vertical alignments was much greater for closed pairs. Line terminations on both sides of the gap enhanced illusory-contour strength, but whether they were collinear or not had little effect.

  16. Use of Cardiac Computed Tomography for Ventricular Volumetry in Late Postoperative Patients with Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2017-04-01

    Full Text Available Background: Cardiac computed tomography (CT has emerged as an alternative to magnetic resonance imaging (MRI for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. Methods: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI in 11 patients (median age, 19 years who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI and semiautomatic 3-dimensional region-growing method (CT were used to measure ventricular volumes. Results: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI, which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI (r=0.88, p<0.001, the right ventricular end-systolic volume index (RV-ESVI (r=0.84, p=0.001, the left ventricular end-diastolic volume index (LV-EDVI (r=0.90, p=0.001, and the LV-ESVI (r=0.55, p=0.079. While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m 2 vs. 175 mL/m 2 , p=0.008; median LV-EDVI: 94 mL/m 2 vs. 92 mL/m 2 , p=0.026, no significant differences were found for the RV-ESVI or LV-ESVI. Conclusion: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.

  17. WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

    International Nuclear Information System (INIS)

    Saleh, H Al; Erickson, B; Paulson, E

    2015-01-01

    Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and was applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves MR image

  18. WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, H Al; Erickson, B; Paulson, E [Medical College of Wisconsin, Milwaukee, WI (United States)

    2015-06-15

    Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and was applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves MR image

  19. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  20. Cardiac Function Remains Impaired Despite Reversible Cardiac Remodeling after Acute Experimental Viral Myocarditis

    Directory of Open Access Journals (Sweden)

    Peter Moritz Becher

    2017-01-01

    Full Text Available Background. Infection with Coxsackievirus B3 induces myocarditis. We aimed to compare the acute and chronic phases of viral myocarditis to identify the immediate effects of cardiac inflammation as well as the long-term effects after resolved inflammation on cardiac fibrosis and consequently on cardiac function. Material and Methods. We infected C57BL/6J mice with Coxsackievirus B3 and determined the hemodynamic function 7 as well as 28 days after infection. Subsequently, we analyzed viral burden and viral replication in the cardiac tissue as well as the expression of cytokines and matrix proteins. Furthermore, cardiac fibroblasts were infected with virus to investigate if viral infection alone induces profibrotic signaling. Results. Severe cardiac inflammation was determined and cardiac fibrosis was consistently colocalized with inflammation during the acute phase of myocarditis. Declined cardiac inflammation but no significantly improved hemodynamic function was observed 28 days after infection. Interestingly, cardiac fibrosis declined to basal levels as well. Both cardiac inflammation and fibrosis were reversible, whereas the hemodynamic function remains impaired after healed viral myocarditis in C57BL/6J mice.

  1. Current role of cardiac and extra-cardiac pathologies in clinically indicated cardiac computed tomography with emphasis on status before pulmonary vein isolation

    Energy Technology Data Exchange (ETDEWEB)

    Sohns, J.M.; Lotz, J. [Goettingen University Medical Center (Germany). Inst. for Diagnostic and Interventional Radiology; German Center for Cardiovascular Research (DZHK), Goettingen (Germany); Menke, J.; Staab, W.; Fasshauer, M.; Kowallick, J.T.; Zwaka, P.A.; Schwarz, A. [Goettingen University Medical Center (Germany). Inst. for Diagnostic and Interventional Radiology; Spiro, J. [Koeln University Hospital (Germany). Radiology; Bergau, L.; Unterberg-Buchwald, C. [Goettingen University Medical Center (Germany). Cardiology and Pneumology

    2014-09-15

    Purpose: The aim of this study was to assess the incidence of cardiac and significant extra-cardiac findings in clinical computed tomography of the heart in patients with atrial fibrillation before pulmonary vein isolation (PVI). Materials and Methods: 224 patients (64 ± 10 years; male 63%) with atrial fibrillation were examined by cardiac 64-slice multidetector CT before PVI. Extra-cardiac findings were classified as 'significant' if they were recommended to additional diagnostics or therapy, and otherwise as 'non-significant'. Additionally, cardiac findings were documented in detail. Results: A total of 724 cardiac findings were identified in 203 patients (91% of patients). Additionally, a total of 619 extra-cardiac findings were identified in 179 patients (80% of patients). Among these extra-cardiac findings 196 (32%) were 'significant', and 423 (68%) were 'non-significant'. In 2 patients (1%) a previously unknown malignancy was detected (esophageal cancer and lung cancer, local stage, no metastasis). 203 additional imaging diagnostics followed to clarify the 'significant' findings (124 additional CT, costs 38,314.69 US dollars). Overall, there were 3.2 cardiac and 2.8 extra-cardiac findings per patient. Extra-cardiac findings appear significantly more frequently in patients over 60 years old, in smokers and in patients with a history of cardiac findings (p < 0.05). Conclusion: Cardiac CT scans before PVI should be screened for extracardiac incidental findings that could have important clinical implications for each patient. (orig.)

  2. Cardiac optogenetic pacing in drosophila melanogaster using red-shifted opsins (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Electrical pacing is the current gold standard for investigation of mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, this method requires an invasive surgical procedure to implant the pacing electrodes. Recently, optogenetic pacing has been developed as an alternative, non-invasive method for heartbeat pacing in animals. It induces heartbeats by shining pulsed light on transgene-generated microbial opsins which in turn activate light gated ion channels in animal hearts. However, commonly used opsins, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we expressed recently engineered red-shifted opsins, ReaChR and CsChrimson, in the heart of a well-developed animal model, Drosophila melanogaster, for the first time. Optogenetic pacing was successfully conducted in both ReaChR and CsChrimson flies at their larval, pupal, and adult stages using 617 nm excitation light pulse, enabling a much deeper tissue penetration compared to blue stimulation light. A customized high speed and ultrahigh resolution OCM system was used to non-invasively monitor the heartbeat pacing in Drosophila. Compared to previous studies on optogenetic pacing of Drosophila, higher penetration depth of optogenetic excitation light was achieved in opaque late pupal flies. Lower stimulating power density is needed for excitation at each developmental stage of both groups, which improves the safety of this technique for heart rhythm studies.

  3. Alveolar Ridge Contouring with Free Connective Tissue Graft at Implant Placement: A 5-Year Consecutive Clinical Study.

    Science.gov (United States)

    Hanser, Thomas; Khoury, Fouad

    2016-01-01

    This study evaluated volume stability after alveolar ridge contouring with free connective tissue grafts at implant placement in single-tooth gaps. A total of 52 single-tooth gaps with labial volume deficiencies in the maxilla (incisors, canines, and premolars) were consecutively treated with implants and concomitant free palatal connective tissue grafts in 46 patients between 2006 and 2009. Implants had to be covered with at least 2 mm peri-implant local bone after insertion. At implant placement, a free connective tissue graft from the palate was fixed inside a labial split-thickness flap to form an existing concave buccal alveolar ridge contour due to tissue volume deficiency into a convex shape. Standardized volumetric measurements of the labial alveolar contour using a template were evaluated before connective tissue grafting and at 2 weeks, 1 year, and 5 years after implantprosthetic incorporation. Tissue volume had increased significantly (P tissue contour of the implant before connective tissue grafting to baseline (2 weeks after implant-prosthetic incorporation). Statistically, 50% of the reference points (P > .05) kept their volume from baseline to 1 year after prosthetic incorporation and from baseline to 5 years after prosthetic incorporation, respectively, whereas reference points located within the area of the implant sulcus showed a significant (P connective tissue grafting appears to be an appropriate long-term means to contour preexisting buccal alveolar volume deficiencies in single implants.

  4. Integration of cardiac computed tomography into pulmonary vein isolation in patients with paroxysmal atrial fibrillation

    International Nuclear Information System (INIS)

    Weber, T.F.; Klemm, H.; Willems, S.; Koops, A.; Adam, G.; Begemann, P.G.; Nagel, H.D.

    2007-01-01

    Purpose: Detailed anatomic information of the left atrium is necessary for securely performing radiofrequency ablation of atrial fibrillation-triggering ectopies in the pulmonary vein ostia. In this study the impact of a preinterventionally acquired cardiac computed tomography (CT) on pulmonary vein isolation (PVI) was assessed. Materials and methods: Examinations of 54 patients with paroxysmal atrial fibrillation undergoing PVI were analyzed. In 27 patients a supplementary cardiac CT was obtained prior to PVI (CT group, 12 women, 15 men, 59.7 ± 9.9 years of age): 16 x 1.5 mm collimation, 0.2 pitch, 120 kV tube voltage, 400 effective mAs. The fluoroscopy time, effective dose and quantity of radiofrequency (RF) pulses of the following catheter ablation were compared to 27 patients undergoing stand-alone PVI (11 women, 16 men, 62.0 ± 9.9 years of age). Mann-Whitney tests served for statistical comparison. Results: CT datasets were successfully integrated into the ablation procedure of each patient in the CT group. The mean quantity of RF pulses was significantly lower in the CT group (22.1 ± 8.0 vs. 29.1 ± 11.9, p = 0.030), and a significant reduction of fluoroscopy time was found (41.8 ± 12.0 min vs. 51.2 ± 16.0 min, p = 0.005). Effective doses of the catheter ablation differed in an equivalent dimension but altogether not significantly (14.9 ± 10.0 mSv vs. 20.0 ± 16.0 mSv, p = 0.203). The mean additive effective dose of the cardiac CT was 85 ± 0.3 mSv. (orig.)

  5. Radiofrequency-assisted Liposuction for Arm Contouring: Technique under Local Anesthesia

    Directory of Open Access Journals (Sweden)

    Spero Theodorou, MD

    2013-08-01

    Conclusions: In appropriately selected patients, RFAL arm contouring under local anesthesia represents an alternative procedure with acceptably low morbidity and high patient satisfaction. To achieve consistent results while minimizing complications, consideration to anatomic details, infiltration of the local anesthetic, and application of the radiofrequency energy must be given.

  6. An Accurate and Efficient Design Tool for Large Contoured Beam Reflectarrays

    DEFF Research Database (Denmark)

    Zhou, Min; Sørensen, Stig B.; Jørgensen, Erik

    2012-01-01

    An accurate and efficient tool for the design of contoured beam reflectarrays is presented. It is based on the Spectral Domain Method of Moments, the Local Periodicity approach, and a minimax optimization algorithm. Contrary to the conventional phase-only optimization techniques, the geometrical...... parameters of the array elements are directly optimized to fulfill the far-field requirements. The design tool can be used to optimize reflectarrays based on a regular grid as well as an irregular grid. Both coand cross-polar radiation can be optimized for multiple frequencies, polarizations, and feed...... illuminations. Two offset contoured beam reflectarrays that radiate a highgain beam on an European coverage have been designed, manufactured, and measured at the DTU-ESA Spherical Near-Field Antenna Test Facility. An excellent agreement is obtained for the simulated and measured patterns. To show the design...

  7. A treatment planning comparison of four target volume contouring guidelines for locally advanced pancreatic cancer radiotherapy

    International Nuclear Information System (INIS)

    Fokas, Emmanouil; Eccles, Cynthia; Patel, Neel; Chu, Kwun-Ye; Warren, Samantha; McKenna, W. Gillies; Brunner, Thomas B.

    2013-01-01

    Background and purpose: Contouring of target volumes varies significantly in radiotherapy of pancreatic ductal adenocarcinoma (PDAC). There is a lack of consensus as to whether elective lymph nodes (eLN’s) should be included or not in the planning target volume (PTV). In the present study we analyzed the dosimetric coverage of the eLN’s and organs at risk (OAR) by comparing four different contouring guidelines. Methods and materials: PTVs were delineated with (Oxford and RTOG guidelines) or without (Michigan and SCALOP guidelines) including the eLNs in eleven patients with PDAC. eLNs included the peripancreatic, paraaortic, paracaval, celiac trunk, superior mesenteric and portal vein clinical target volumes (CTVs). A 3D-CRT plan (50.40 Gy in 28 fractions) was performed to analyze and compare the dosimetric coverage of all eLNs and OAR between the 4 contouring guidelines. Results: The size of Oxford and RTOG PTVs was comparable and significantly larger than the SCALOP and Michigan PTVs. Interestingly the eLNs received a significant amount of incidental dose irradiation by PTV-based plans that only aimed to treat the tumor without the eLNs. The dosimetric coverage of eLN presented a large variability according to the respective contouring methods. The difference in the size of the 4 PTVs was reflected to the dose distribution at the OAR. Conclusions: Our study provides important information regarding the impact of different contouring guidelines on the dose distribution to the eLNs and the OAR in patients with locally advanced PDAC treated with radiotherapy

  8. Effect of Contour Shape of Nervous System Electromagnetic Stimulation Coils on the Induced Electrical Field Distribution

    Directory of Open Access Journals (Sweden)

    Daskalov Ivan K

    2002-05-01

    Full Text Available Abstract Background Electromagnetic stimulation of the nervous system has the advantage of reduced discomfort in activating nerves. For brain structures stimulation, it has become a clinically accepted modality. Coil designs usually consider factors such as optimization of induced power, focussing, field shape etc. In this study we are attempting to find the effect of the coil contour shape on the electrical field distribution for magnetic stimulation. Method and results We use the maximum of the induced electric field stimulation in the region of interest as the optimization criterion. This choice required the application of the calculus of variation, with the contour perimeter taken as a pre-set condition. Four types of coils are studied and compared: circular, square, triangular and an 'optimally' shaped contour. The latter yields higher values of the induced electrical field in depths up to about 30 mm, but for depths around 100 mm, the circular shape has a slight advantage. The validity of the model results was checked by experimental measurements in a tank with saline solution, where differences of about 12% were found. In view the accuracy limitations of the computational and measurement methods used, such differences are considered acceptable. Conclusion We applied an optimization approach, using the calculus of variation, which allows to obtain a coil contour shape corresponding to a selected criterion. In this case, the optimal contour showed higher intensities for a longer line along the depth-axis. The method allows modifying the induced field structure and focussing the field to a selected zone or line.

  9. Epidemiology and Outcomes After In-Hospital Cardiac Arrest After Pediatric Cardiac Surgery

    Science.gov (United States)

    Gupta, Punkaj; Jacobs, Jeffrey P.; Pasquali, Sara K.; Hill, Kevin D.; Gaynor, J. William; O’Brien, Sean M.; He, Max; Sheng, Shubin; Schexnayder, Stephen M.; Berg, Robert A.; Nadkarni, Vinay M.; Imamura, Michiaki; Jacobs, Marshall L.

    2014-01-01

    Background Multicenter data regarding cardiac arrest in children undergoing heart operations are limited. We describe epidemiology and outcomes associated with postoperative cardiac arrest in a large multiinstitutional cohort. Methods Patients younger than 18 years in the Society of Thoracic Surgeons Congenital Heart Surgery Database (2007 through 2012) were included. Patient factors, operative characteristics, and outcomes were described for patients with and without postoperative cardiac arrest. Multivariable models were used to evaluate the association of center volume with cardiac arrest rate and mortality after cardiac arrest, adjusting for patient and procedural factors. Results Of 70,270 patients (97 centers), 1,843 (2.6%) had postoperative cardiac arrest. Younger age, lower weight, and presence of preoperative morbidities (all p < 0.0001) were associated with cardiac arrest. Arrest rate increased with procedural complexity across common benchmark operations, ranging from 0.7% (ventricular septal defect repair) to 12.7% (Norwood operation). Cardiac arrest was associated with significant mortality risk across procedures, ranging from 15.4% to 62.3% (all p < 0.0001). In multivariable analysis, arrest rate was not associated with center volume (odds ratio, 1.06; 95% confidence interval, 0.71 to 1.57 in low- versus high-volume centers). However, mortality after cardiac arrest was higher in low-volume centers (odds ratio, 2.00; 95% confidence interval, 1.52 to 2.63). This association was present for both high- and low-complexity operations. Conclusions Cardiac arrest carries a significant mortality risk across the stratum of procedural complexity. Although arrest rates are not associated with center volume, lower-volume centers have increased mortality after cardiac arrest. Further study of mechanisms to prevent cardiac arrest and to reduce mortality in those with an arrest is warranted. PMID:25443018

  10. The Diagnostic Value of Pulsed Wave Tissue Doppler Imaging in Asymptomatic Beta- Thalassemia Major Children and Young Adults; Relation to Chemical Biomarkers of Left Ventricular Function and Iron Overload.

    Science.gov (United States)

    Ragab, Seham M; Fathy, Waleed M; El-Aziz, Walaa FAbd; Helal, Rasha T

    2015-01-01

    Cardiac iron toxicity is the leading cause of death among β-halassaemia major (TM) patients. Once heart failure becomes overt, it is difficult to reverse. To investigate non-overt cardiac dysfunctions in TM patients using pulsed wave Tissue Doppler Imaging (TD I) and its relation to iron overload and brain natriuretic peptide (BNP). Thorough clinical, conventional echo and pulsed wave TDI parameters were compared between asymptomatic 25 β-TM patients and 20 age and gender matched individuals. Serum ferritin and plasma BNP levels were assayed by ELISA. TM patients had significant higher mitral inflow early diastolic (E) wave and non significant other conventional echo parameters. In the patient group, pulsed wave TDI revealed systolic dysfunctions, in the form of significant higher isovolumetric contraction time (ICT), and lower ejection time (E T), with diastolic dysfunction in the form of higher isovolumetric relaxation time (IRT), and lower mitral annulus early diastolic velocity E' (12.07 ±2.06 vs 15.04±2.65, P= 0.003) compared to the controls. Plasma BNP was higher in patients compared to the controls. Plasma BNP and serum ferritin had a significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions. Patients with E/E' ≥ 8 had significant higher serum ferritin and plasma BNP levels compared to those with ratio wave TDI is an important diagnostic tool for latent cardiac dysfunction in iron-loaded TM patients and is related to iron overload and BNP.

  11. THE DIAGNOSTIC VALUE OF PULSED WAVE TISSUE DOPPLER IMAGING IN ASYMPTOMATIC BETA- THALASSEMIA MAJOR CHILDREN AND YOUNG ADULTS ; RELATION TO CHEMICAL BIOMARKERS OF LEFT VENTRICULAR FUNCTION AND IRON OVERLOAD .

    Directory of Open Access Journals (Sweden)

    Seham Ragab

    2015-08-01

    Full Text Available Background: Cardiac iron toxicity is the leading cause of death among  β-halassaemia major (TM  patients.  Once  heart failure becomes overt , it will be  difficult to reverse . Objectives: To investigate non overt cardiac dysfunctions  in TM patients using  pulsed wave Tissue Doppler  Imaging (TD I and its relation to the iron overload and brain natruritic peptide (BNP. Methods: Thorough  clinical , conventional echo and  pulsed  wave TDI  parameters were compared between  asymtomatic 25 β-TM  patients  and 20 age and gender matched individuals. Serum ferritin and plasma BNP  levels were assayed by  ELISA .  Results: TM patients had significant higher mitral inflow early diastolic (E wave and  non significant other conventional echo  parameters. Pulsed wave TDI revealed systolic and diastolic dysfunctions in the form of significant higher  isovolumetric contraction time (ICT , ejection time ( E T and  isovolumetric relaxation time (IRT with significantly lower  mitral annulus  early diastolic velocity E` (12.07 ±2.06 vs 15.04±2.65 ,P= 0.003  in patients compared to  controls. Plasma BNP was higher in patients compared to the controls.  Plasma BNP and serum ferritin had significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions.  Patients with E/E` ≥ 8 had  significant higher  serum ferritin  and plasma BNP levels compared to those with E/E` ratio < 8 without difference in Hb levels .Conclusion:  Pulsed wave TDI  is an  important diagnostic tool for latent cardiac dysfunction in iron loaded TM patients and is related to iron overload and BNP .

  12. Cardiac Bmi1(+) cells contribute to myocardial renewal in the murine adult heart.

    Science.gov (United States)

    Valiente-Alandi, Iñigo; Albo-Castellanos, Carmen; Herrero, Diego; Arza, Elvira; Garcia-Gomez, Maria; Segovia, José C; Capecchi, Mario; Bernad, Antonio

    2015-10-26

    The mammalian adult heart maintains a continuous, low cardiomyocyte turnover rate throughout life. Although many cardiac stem cell populations have been studied, the natural source for homeostatic repair has not yet been defined. The Polycomb protein BMI1 is the most representative marker of mouse adult stem cell systems. We have evaluated the relevance and role of cardiac Bmi1 (+) cells in cardiac physiological homeostasis. Bmi1 (CreER/+);Rosa26 (YFP/+) (Bmi1-YFP) mice were used for lineage tracing strategy. After tamoxifen (TM) induction, yellow fluorescent protein (YFP) is expressed under the control of Rosa26 regulatory sequences in Bmi1 (+) cells. These cells and their progeny were tracked by FACS, immunofluorescence and RT-qPCR techniques from 5 days to 1 year. FACS analysis of non-cardiomyocyte compartment from TM-induced Bmi1-YFP mice showed a Bmi1 (+)-expressing cardiac progenitor cell (Bmi1-CPC: B-CPC) population, SCA-1 antigen-positive (95.9 ± 0.4 %) that expresses some stemness-associated genes. B-CPC were also able to differentiate in vitro to the three main cardiac lineages. Pulse-chase analysis showed that B-CPC remained quite stable for extended periods (up to 1 year), which suggests that this Bmi1 (+) population contains cardiac progenitors with substantial self-maintenance potential. Specific immunostaining of Bmi1-YFP hearts serial sections 5 days post-TM induction indicated broad distribution of B-CPC, which were detected in variably sized clusters, although no YFP(+) cardiomyocytes (CM) were detected at this time. Between 2 to 12 months after TM induction, YFP(+) CM were clearly identified (3 ± 0.6 % to 6.7 ± 1.3 %) by immunohistochemistry of serial sections and by flow cytometry of total freshly isolated CM. B-CPC also contributed to endothelial and smooth muscle (SM) lineages in vivo. High Bmi1 expression identifies a non-cardiomyocyte resident cardiac population (B-CPC) that contributes to the main lineages of the heart in

  13. Reference Values for Cardiac and Aortic Magnetic Resonance Imaging in Healthy, Young Caucasian Adults.

    Science.gov (United States)

    Eikendal, Anouk L M; Bots, Michiel L; Haaring, Cees; Saam, Tobias; van der Geest, Rob J; Westenberg, Jos J M; den Ruijter, Hester M; Hoefer, Imo E; Leiner, Tim

    2016-01-01

    Reference values for morphological and functional parameters of the cardiovascular system in early life are relevant since they may help to identify young adults who fall outside the physiological range of arterial and cardiac ageing. This study provides age and sex specific reference values for aortic wall characteristics, cardiac function parameters and aortic pulse wave velocity (PWV) in a population-based sample of healthy, young adults using magnetic resonance (MR) imaging. In 131 randomly selected healthy, young adults aged between 25 and 35 years (mean age 31.8 years, 63 men) of the general-population based Atherosclerosis-Monitoring-and-Biomarker-measurements-In-The-YOuNg (AMBITYON) study, descending thoracic aortic dimensions and wall thickness, thoracic aortic PWV and cardiac function parameters were measured using a 3.0T MR-system. Age and sex specific reference values were generated using dedicated software. Differences in reference values between two age groups (25-30 and 30-35 years) and both sexes were tested. Aortic diameters and areas were higher in the older age group (all page or sex effect. This study provides age and sex specific reference values for cardiovascular MR parameters in healthy, young Caucasian adults. These may aid in MR guided pre-clinical identification of young adults who fall outside the physiological range of arterial and cardiac ageing.

  14. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  15. Development of optical surface contouring technique using laser

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Sung Hoon; Kim, Min Suk; Park, Seung Kyu

    1998-12-01

    Laser contouring system capable of measuring relief profiles using a line-shaped laser beam with anisotropic magnification optics composed with two cylindrical lenses was developed. The anisotropic magnification optical system allows it to obtain higher resolution in the relief profile measurements. The image processing and 3-D display software are developed to reconstruct 3-D shape. The power supply of laser diode with adaptive current control circuit is designed. (author). 4 refs., 5 tabs., 33 figs.

  16. Investigation of Raman bands vapour of contours of trichloroethylene at high pressure

    International Nuclear Information System (INIS)

    Zaleskaya, G.A.; Ikramov, M.; Shukurov, T.

    1989-01-01

    Investigation of high-pressure extraneous gas on contour comb. band, spreading trichloroethylene steams are in given article. Increasing of extraneous gas pressure brings to decreasing free molecule circling time is shown

  17. Lymph node segmentation by dynamic programming and active contours.

    Science.gov (United States)

    Tan, Yongqiang; Lu, Lin; Bonde, Apurva; Wang, Deling; Qi, Jing; Schwartz, Lawrence H; Zhao, Binsheng

    2018-03-03

    Enlarged lymph nodes are indicators of cancer staging, and the change in their size is a reflection of treatment response. Automatic lymph node segmentation is challenging, as the boundary can be unclear and the surrounding structures complex. This work communicates a new three-dimensional algorithm for the segmentation of enlarged lymph nodes. The algorithm requires a user to draw a region of interest (ROI) enclosing the lymph node. Rays are cast from the center of the ROI, and the intersections of the rays and the boundary of the lymph node form a triangle mesh. The intersection points are determined by dynamic programming. The triangle mesh initializes an active contour which evolves to low-energy boundary. Three radiologists independently delineated the contours of 54 lesions from 48 patients. Dice coefficient was used to evaluate the algorithm's performance. The mean Dice coefficient between computer and the majority vote results was 83.2%. The mean Dice coefficients between the three radiologists' manual segmentations were 84.6%, 86.2%, and 88.3%. The performance of this segmentation algorithm suggests its potential clinical value for quantifying enlarged lymph nodes. © 2018 American Association of Physicists in Medicine.

  18. Long pacing pulses reduce phrenic nerve stimulation in left ventricular pacing.

    Science.gov (United States)

    Hjortshøj, Søren; Heath, Finn; Haugland, Morten; Eschen, Ole; Thøgersen, Anna Margrethe; Riahi, Sam; Toft, Egon; Struijk, Johannes Jan

    2014-05-01

    Phrenic nerve stimulation is a major obstacle in cardiac resynchronization therapy (CRT). Activation characteristics of the heart and phrenic nerve are different with higher chronaxie for the heart. Therefore, longer pulse durations could be beneficial in preventing phrenic nerve stimulation during CRT due to a decreased threshold for the heart compared with the phrenic nerve. We investigated if long pulse durations decreased left ventricular (LV) thresholds relatively to phrenic nerve thresholds in humans. Eleven patients, with indication for CRT and phrenic nerve stimulation at the intended pacing site, underwent determination of thresholds for the heart and phrenic nerve at different pulse durations (0.3-2.9 milliseconds). The resulting strength duration curves were analyzed by determining chronaxie and rheobase. Comparisons for those parameters were made between the heart and phrenic nerve, and between the models of Weiss and Lapicque as well. In 9 of 11 cases, the thresholds decreased faster for the LV than for the phrenic nerve with increasing pulse duration. In 3 cases, the thresholds changed from unfavorable for LV stimulation to more than a factor 2 in favor of the LV. The greatest change occurred for pulse durations up to 1.5 milliseconds. The chronaxie of the heart was significantly higher than the chronaxie of the phrenic nerve (0.47 milliseconds vs. 0.22 milliseconds [P = 0.029, Lapicque] and 0.79 milliseconds vs. 0.27 milliseconds [P = 0.033, Weiss]). Long pulse durations lead to a decreased threshold of the heart relatively to the phrenic nerve and may prevent stimulation of the phrenic nerve in a clinical setting. © 2013 Wiley Periodicals, Inc.

  19. SU-E-T-182: Feasibility of Dose Painting by Numbers in Proton Therapy with Contour-Driven Plan Optimization

    International Nuclear Information System (INIS)

    Montero, A Barragan; Differding, S; Lee, J; Sterpin, E

    2014-01-01

    Purpose: The work aims to 1) prove the feasibility of dose painting by numbers (DPBN) in proton therapy with usual contour-driven plan optimization and 2) compare the achieved plan quality to that of rotational IMRT. Methods: For two patients with head and neck cancers, voxel-by-voxel prescription to the target volume (PTV-PET) was calculated from 18 FDG-PET images and converted to contour-based prescription by defining several sub-contours. Treatments were planned with RayStation (RaySearch Laboratories, Sweden) and proton pencil beam scanning modality. In order to determine the optimal plan parameters to approach the DPBN prescription, the effect of the number of fields, number of sub-contours and use of range shifter were tested separately on each patient. The number of sub-contours were increased from 3 to 11 while the number of fields were set to 3, 5, 7 and 9. Treatment plans were also optimized on two rotational IMRT systems (TomoTherapy and Varian RapidArc) using previously published guidelines. Results: For both patients, more than 99% of the PTV-PET received at least 95% of the prescribed dose while less than 1% of the PTV-PET received more than 105%, which demonstrates the feasibility of the treatment. Neither the use of a range shifter nor the increase of the number of fields had a significant influence on PTV coverage. Plan quality increased when increasing number of fields up to 7 or 9 and slightly decreased for a bigger number of sub-contours. Good OAR sparing is achieved while keeping high plan quality. Finally, proton therapy achieved significantly better plan quality than rotational IMRT. Conclusion: Voxel-by-voxel prescriptions can be approximated accurately in proton therapy using a contour-driven optimization. Target coverage is nearly insensitive to the number of fields and the use of a range shifter. Finally, plan quality assessment confirmed the superiority of proton therapy compared to rotational IMRT

  20. Prediction of the Velocity Contours in Triangular Channel with Non-uniform Roughness Distributions by Adaptive Neuro-Fuzzy Inference System

    Directory of Open Access Journals (Sweden)

    Sara Bardestani

    2017-09-01

    Full Text Available Triangular channels have different applications in many water and wastewater engineering problems. For this purpose investigating hydraulic characteristics of flow in these sections has great importance. Researchers have presented different prediction methods for the velocity contours in prismatic sections. Most proposed methods are not able to consider the effect of walls roughness, the roughness distribution and secondary flows. However, due to complexity and nonlinearity of velocity contours in open channel flow, there is no simple relationship that can be fully able to exactly draw the velocity contours. In this paper an efficient approach for modeling velocity contours in triangular open channels with non-uniform roughness distributions by Adaptive Neuro-Fuzzy Inference System (ANFIS has been suggested. For training and testing model, the experimental data including 1703 data in triangular channels with geometric symmetry and non-uniform roughness distributions have been used. Comparing experimental results with predicted values by model indicates that ANFIS model is capable to be used in simulation of local velocity and determining velocity contours and the independent evaluation showed that the calculated values of discharge and depth-averaged velocity from model information are precisely in conformity with experimental values.