WorldWideScience

Sample records for pulse columns

  1. Annular pulse column development studies

    International Nuclear Information System (INIS)

    Benedict, G.E.

    1980-01-01

    The capacity of critically safe cylindrical pulse columns limits the size of nuclear fuel solvent extraction plants because of the limited cross-sectional area of plutonium, U-235, or U-233 processing columns. Thus, there is a need to increase the cross-sectional area of these columns. This can be accomplished through the use of a column having an annular cross section. The preliminary testing of a pilot-plant-scale annular column has been completed and is reported herein. The column is made from 152.4-mm (6-in.) glass pipe sections with an 89-mm (3.5-in.) o.d. internal tube, giving an annular width of 32-mm (1.25-in.). Louver plates are used to swirl the column contents to prevent channeling of the phases. The data from this testing indicate that this approach can successfully provide larger-cross-section critically safe pulse columns. While the capacity is only 70% of that of a cylindrical column of similar cross section, the efficiency is almost identical to that of a cylindrical column. No evidence was seen of any non-uniform pulsing action from one side of the column to the other

  2. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  3. Pulse amplitude and frequency effects in a pulsed packed column

    Energy Technology Data Exchange (ETDEWEB)

    Russell, S H

    1954-04-15

    A study has been made of the effect on the efficiency and capacity of applying pulses of varying amplitude and frequency to a packed column. In the efficiency studies, the maximum efficiency was obtained with a pulse having an amplitude of 3/8'' and a frequency of 140 cycles per minute. Under these conditions, the column was about five times as efficient as a simple packed column. Two general types of results were obtained in the capacity studies. Under certain conditions, the capacity increased over that of a simple packed column, but under others, it decreased. Some of the factors causing this were investigated but the fundamental reasons were not determined due to a lack of personnel for the necessary experiments. (author)

  4. Pulse amplitude and frequency effects in a pulsed packed column

    International Nuclear Information System (INIS)

    Russell, S.H.

    1954-04-01

    A study has been made of the effect on the efficiency and capacity of applying pulses of varying amplitude and frequency to a packed column. In the efficiency studies, the maximum efficiency was obtained with a pulse having an amplitude of 3/8'' and a frequency of 140 cycles per minute. Under these conditions, the column was about five times as efficient as a simple packed column. Two general types of results were obtained in the capacity studies. Under certain conditions, the capacity increased over that of a simple packed column, but under others, it decreased. Some of the factors causing this were investigated but the fundamental reasons were not determined due to a lack of personnel for the necessary experiments. (author)

  5. Calculation code PULCO for Purex process in pulsed column

    International Nuclear Information System (INIS)

    Gonda, Kozo; Matsuda, Teruo

    1982-03-01

    The calculation code PULCO, which can simulate the Purex process using a pulsed column as an extractor, has been developed. The PULCO is based on the fundamental concept of mass transfer that the mass transfer within a pulsed column occurs through the interface of liquid drops and continuous phase fluid, and is the calculation code different from conventional ones, by which various phenomena such as the generation of liquid drops, their rising and falling, and the unification of liquid drops actually occurring in a pulsed column are exactly reflected and can be correctly simulated. In the PULCO, the actually measured values of the fundamental quantities representing the extraction behavior of liquid drops in a pulsed column are incorporated, such as the mass transfer coefficient of each component, the diameter and velocity of liquid drops in a pulsed column, the holdup of dispersed phase, and axial turbulent flow diffusion coefficient. The verification of the results calculated with the PULCO was carried out by installing a pulsed column of 50 mm inside diameter and 2 m length with 40 plate stage in a glove box for unirradiated uranium-plutonium mixed system. The results of the calculation and test were in good agreement, and the validity of the PULCO was confirmed. (Kako, I.)

  6. Effect of backmixing on pulse column performance

    International Nuclear Information System (INIS)

    Miao, Y.W.

    1979-05-01

    A critical survey of the published literature concerning dispersed phase holdup and longitudinal mixing in pulsed sieve-plate extraction columns has been made to assess the present state-of-the-art in predicting these two parameters, both of which are of critical importance in the development of an accurate mathematical model of the pulse column. Although there are many conflicting correlations of these variables as a function of column geometry, operating conditions, and physical properties of the liquid systems involved it has been possible to develop new correlations which appear to be useful and which are consistent with much of the available data over the limited range of variables most likely to be encountered in plant sized equipment. The correlations developed were used in a stagewise model of the pulse column to predict product concentrations, solute inventory, and concentration profiles in a column for which limited experimental data were available. Reasonable agreement was obtained between the mathematical model and the experimental data. Complete agreement, however, can only be obtained after a correlation for the extraction efficiency has been developed. The correlation of extraction efficiency was beyond the scope of this work

  7. Study of hydrodynamic and mass transfer parameters in pulsed sieve-plate columns

    International Nuclear Information System (INIS)

    Safdari, J.

    2001-01-01

    One of the most important liquid-liquid extractor in industry is pulsed column. The pulsed columns are generally classified into the following categories: 1-Pulsed perforated-plate column. 2- Pulsed packed column. The pulsed plate column is differential contactor with the application of mechanical energy and is used for a diverse range of processes. Probably its best known application has been in the nuclear fuel industry. The pulsed plate column consists of a cylindrical shell with settling zones at the top and the bottom of the column. The liquids are fed continuously to the column (flowing counter-currently) and are removed continuously from opposite ends of the column. In this work using a pilot pulsed plate column and two different chemical systems (toluene/acetone/water and n-butyl acetate/acetone/water) various experiments are carried out. In each experiment direction of mass transfer is from organic phase (dispersed phase) into aqueous phase (continuous phase) and the continuous phase is water. The main objects of this thesis are as follow: a- Investigation of effect of operating parameters on dispersed phase hold up, volumetric overall mass transfer coefficients based on dispersed and continuous phase, extraction efficiency, pressure drop of column and flooding velocities (maximum column capacities). Obtained results in this part show that if the calorimetric flow rate of aqueous phase or pulsation intensity increase, hold up, volumetric overall mass transfer coefficients based on both two phases and extraction efficiency will increase and flooding velocities will decrease. Also results show that if volumetric flow rate of organic phase increase, hold up, volumetric mass transfer coefficients based on both two phases and pressure drop will increase and extraction efficiency and flooding velocities will decrease. b- Investigation of effect of internal circulation inside drops in designing pulsed perforated-plate column

  8. Operation of the annular pulsed column, (2)

    International Nuclear Information System (INIS)

    Takahashi, Keiki; Tsukada, Takeshi

    1988-01-01

    The heat of reaction generated form the uranium extraction is considered to from the temperature profile inside the pulsed column. A simulation code was developed to estimate the temperature profile, considering heat generation and counter-current heat transfer. The temperature profiles calculated using this code was found to depend on both the position of the extraction zone and the operating condition. The reported experimental result was fairly represented by this simulation code. We consider that this presented simulation code is capable of providing with the temperature profile in the pulsed column and useful for the monitoring of the uranium extraction zone. (author)

  9. Applicability of hydroxylamine nitrate reductant in pulse-column contactors

    International Nuclear Information System (INIS)

    Reif, D.J.

    1983-05-01

    Uranium and plutonium separations were made from simulated breeder reactor spent fuel dissolver solution with laboratory-sized pulse column contactors. Hydroxylamine nitrate (HAN) was used for reduction of plutonium (1V). An integrated extraction-partition system, simulating a breeder fuel reprocessing flowsheet, carried out a partial partition of uranium and plutonium in the second contactor. Tests have shown that acceptable coprocessing can be ontained using HAN as a plutonium reductant. Pulse column performance was stable even though gaseous HAN oxidation products were present in the column. Gas evolution rates up to 0.27 cfm/ft 2 of column cross section were tested and found acceptable

  10. Alpha-contained laboratory scale pulse column facility for SRL

    International Nuclear Information System (INIS)

    Reif, D.J.; Cadieux, J.R.; Fauth, D.J.; Thompson, M.C.

    1980-01-01

    For studying solvent extraction processes, a laboratory-sized pulse column facility was constructed at the Savannah River Laboratory. This facility, in conjunction with existing miniature mixer-settler equipment and the centrifugal contactor facility currently under construction at SRL, provides capability for cross comparison of solvent extraction technology. This presentation describes the design and applications of the Pulse Column Facility at SRL

  11. Study on two phase flow characteristics in annular pulsed extraction column with different ratio of annular width to column diameter

    International Nuclear Information System (INIS)

    Qin Wei; Dai Youyuan; Wang Jiading

    1994-01-01

    Annular pulsed extraction column can successfully provide large throughput and can be made critically safe for fuel reprocessing. This investigation is to study the two phase flow characteristics in annular pulsed extraction column with four different annular width. 30% TBP (in kerosene)-water is used (water as continuous phase). Results show that modified Pratt correlation is valid under the experimental operation conditions for the annular pulsed extraction column. The characteristic velocity U K decreased with the increase of energy input and increased with the increase of the ratio of annular width to column diameter. Flooding velocity correlation is suggested. The deviation of the calculated values from the experimental data is within +20% for four annular width in a pulsed extraction column

  12. Technical contribution to the project and operation of pulsed columns

    International Nuclear Information System (INIS)

    Kromek, I.B.; Ikuta, A.

    1976-01-01

    Characteristics and factors that affect the performance of pulse columms used in the purification of metals as thorium, uranium and plutonium are described. The pulse generator and the control instrumentation of these columns are also described. This report is based mainly in the works made by Richardson and Platt and adaptations realized in the project and instalation of the first compound extraction-scrub pulse column in the CEQ/IEA (Sao Paulo, Brazil) [pt

  13. Mathematical model and simulation of the hydrodynamic of air-pulsed sieve plate columns

    International Nuclear Information System (INIS)

    Hannappel, J.; Pfeifer, W.; Rathjen, E.

    1979-02-01

    In this work the dynamic flow events in an air pulsed sieve plate column are described by a simulation model. The model consists of a system of differential equations. The pressure built up by the pulsed air is brought to equilibrium with the pressure losses of the oscillating liquid column in the pulsation tube and in the column. In case of definition of the a) column geometry, b) integral holdup of the column, c) density of the participating phases, d) control times of the pulsed air valves, e) pulse repetition frequency and pulsed air reservoir pressure the height of oscillation and hence the intensity of pulsation are calculated. It is shown by a concrete example that 1) the oscillation of the liquid column in the pulsation tube and in the column is sinusoidal in all cases; 2) generation of a defined pulsation is restricted to the range between 0.3 and 3 Hz; 3) the amount of air needed for pulsation depends on the geometry of the column and in the intensity of pulsation. It can be optimized by appropriate selection of the diameter of the pulsation tube. (orig.) [de

  14. Ion pulse propagation through a previously unfilled electrostatic aperture lens accelerating column

    International Nuclear Information System (INIS)

    Rutkowski, H.L.; Eylon, S.; Keeney, D.S.; Chen, Y.J.; Hewett, D.W.; Barnard, J.

    1993-01-01

    Heavy Ion Fusion experiments require very high current beams with excellent beam quality during a short pulse. Scaled experiments planned at LBL require very short pulses (μsec) compared to what one expects in an HIF driver (20-30 μs). A 1MV acceleration column composed of aperture lenses has been constructed at LBL in order to study the propagation effects on such ion pulses. The column is initially empty of space charge but with the full acceleration potential applied. A short current pulse is then injected into the column with a planar diode open-quotes current valve.close quotes Effects on the pulse propagation due to rise time, pulse duration, and beam size have been studied. Experiments on transported beam current and emittance have been conducted using a carbon arc plasma source (2 double-prime and .5 double-prime diameter) and a 1 double-prime diameter alumino-silicate potassium ion source. Computer simulations using a 2.5D time dependent code are compared with the experimental data

  15. Development of pulsed plate columns for fast reactor fuel reprocessing

    International Nuclear Information System (INIS)

    Jenkins, J.A.; Logsdail, D.H.; Lyall, E.; Myers, P.E.; Partridge, B.A.

    1987-01-01

    The UK Atomic Energy Authority has undertaken a development programme on solvent extraction equipment for reprocessing fast reactor fuels. As part of this programme a solvent extraction pilot plant has been built at Harwell in which a variety of flowsheet conditions can be simulated using the system uranyl nitrate/nitric acid (UN/HNO 3 ) - 20% tri-n-butyl phosphate in odourless kerosene (TBP/OK). The main purpose of present pilot plant operations is to study the performance of pulsed plate columns, with the following specific objectives: to measure the volumetric throughput capacity of the columns, - to study the effect of scale-up of column diameter on U mass transfer performance, - to provide hydraulic and mass transfer data for a dynamic simulation model of pulsed column operation, - to develop and test instruments and ancillary equipment. This poster describes the pilot plant and is illustrated by experimental data, with particular reference to an external settler for controlling the removal of aqueous phase from columns operated with the aqueous phase dispersed

  16. Flooding characteristics of pulsed-sieve plate column. Contributed Paper ED-09

    International Nuclear Information System (INIS)

    Vishnu Anand, P.; Pandey, N.K.; Rajeev, R.; Joyakin, C.V.; Kamachi Mudali, U.; Natarajan, R.

    2014-01-01

    Successful design of a pulsed sieve plate extraction column relies on profound understanding of its hydrodynamic and mass transfer characteristics. Present work outlines a comprehensive study of flooding velocity, a hydrodynamic parameter, as a function of various operating conditions of the column. Experimental studies were carried out using water-normal paraffin hydrocarbon system, under no mass transfer condition, in a pilot plant pulsed sieve plate column equipped with standard plate cartridges. Flooding velocity is characterized here as a function of phase flow ratio and pulse velocity with the aid of characteristic velocity concept together with an exponential function. Flooding points were experimentally identified with satisfactory accuracy using a quantitative method and dispersed phase hold-up was measured by online sampling. To verify the extent of applicability of some of the reported generalized flooding correlations from a design perspective, an analysis was done using our precisely generated experimental flooding data. (author)

  17. Lithium-sodium separation by ion-exchange. Particular study of a pulsed column

    International Nuclear Information System (INIS)

    Auvert, H.

    1966-02-01

    A study is made of the operational conditions and constraints in the case of a moving-bed ion-exchange column subjected to pulses. The example chosen to illustrate its application concerns the lithium-sodium separation in a hydroxide medium (LiOH, NaOH). In the first part, the physico-chemical characteristics of the exchange and the kinetic characteristics of the exchange-reaction are considered. In the second part, the operation of the pulsed column is studied. Using the results obtained in the first part, the conditions required for study state operation are determined. When this is obtained, it is possible to calculate the height equivalent of the theoretical plate (HETP) of the installation. A study is also made of 'sliding', a phenomenon peculiar to pulsed columns. The results obtained show that it is possible, using laboratory tests, to determine the characteristics and the operational condition of a moving-bed ion-exchange column. (author) [fr

  18. Comparison of predicted and measured pulsed-column profiles and inventories

    International Nuclear Information System (INIS)

    Ostenak, C.A.; Cermak, A.F.

    1983-01-01

    Nuclear materials accounting and process control in fuels reprocessing plants can be improved by near-real-time estimation of the in-process inventory in solvent-extraction contactors. Experimental studies were conducted on pilot- and plant-scale pulsed columns by Allied-General Nuclear Service (AGNS), and the extensive uranium concentration-profile and inventory data were analyzed by Los Alamos and AGNS to develop and evaluate different predictive inventory techniques. Preliminary comparisons of predicted and measured pulsed-column profiles and inventories show promise for using these predictive techniques to improve nuclear materials accounting and process control in fuels reprocessing plants

  19. Detection of uranium extraction zone by axial temperature profiles in a pulsed column for Purex process

    International Nuclear Information System (INIS)

    Tsukada, T.; Takahashi, K.

    1991-01-01

    A new method was presented for detecting uranium extraction zone in a pulsed column by means of measuring axial temperature profile originated from reaction heat during uranium extraction. Key parameters of the temperature profiles were estimated with a code developed for calculating temperature profiles in a direct-contact heat exchanger such as a pulsed column, and were verified using data from a small pulsed column simulating reaction heat with injecting hot water. Finally, the results were compared with those from an actual uranium extraction tests, indicating that the method presented was promising for detecting uranium extraction zone in a pulsed column. (author)

  20. Consolidated Fuel Reprocessing Program. Operating experience with pulsed-column holdup estimators

    International Nuclear Information System (INIS)

    Ehinger, M.H.

    1986-01-01

    Methods for estimating pulsed-column holdup are being investigated as part of the Safeguards Assessment task of the Consolidated Fuel Reprocessing Program (CFRP) at the Oak Ridge National Laboratory. The CFRP was a major sponsor of test runs at the Barnwell Nuclear Fuel plant (BNFP) in 1980 and 1981. During these tests, considerable measurement data were collected for pulsed columns in the plutonium purification portion of the plant. These data have been used to evaluate and compare three available methods of holdup estimation

  1. Bradsim-prediction of solute concentration. Temperature and physical property profiles along pulsed plate columns

    International Nuclear Information System (INIS)

    Logsdail, D.H.; Evans, S.F.; Jenkins, J.A.; Smith, I.J.

    1988-01-01

    Dynamic model of the operation of the BRADSIM pulsed plate column is developed. Examples of simulation of the pures process extraction system are given. Profiles of dissolved substances concentrations and profiles of physical properties of liquid along the column are provided. Calculated values are compared with the experimental data, obtained in case of the column 50 mm in diameter, Harwell extractional facility and Sellafield pulsed column 300 mm in diameter for extraction systems uranyl nitrate-nitric acid-20% and 30% TBP in kerosene. 2 refs.; 6 figs

  2. Study on the dynamic holdup distribution of the pulsed extraction column

    International Nuclear Information System (INIS)

    Wang, S.; Chen, J.; Wu, Q.

    2013-01-01

    In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

  3. Study on the dynamic holdup distribution of the pulsed extraction column

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.; Chen, J.; Wu, Q. [Tsinghua University, Beijing 100084 (China)

    2013-07-01

    In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

  4. Survey of simulation methods for modeling pulsed sieve-plate extraction columns

    International Nuclear Information System (INIS)

    Burkhart, L.

    1979-03-01

    The report first considers briefly the use of liquid-liquid extraction in nuclear fuel reprocessing and then describes the operation of the pulse column. Currently available simulation models of the column are reviewed, and followed by an analysis of the information presently available from which the necessary parameters can be obtained for use in a model of the column. Finally, overall conclusions are given regarding the information needed to develop an accurate model of the column for materials accountability in fuel reprocessing plants. 156 references

  5. A study of pulse columns for thorium fuel reprocessing

    International Nuclear Information System (INIS)

    Fumoto, H.

    1982-03-01

    Two 5 m pulse columns with the same cartridge geometries are installed to investigate the performance. The characteristic differences of the aqueous continous and the organic continuous columns were investigated experimentally. A ternary system of 30% TBP in dodecane-acetic acid-water was adopted for the mass-transfer study. It was concluded that the overall mass-transfer coefficient was independent of whether the mass-transfer is from the dispersed to the continuous phase or from the continuous to the dispersed phase. Thorium nitrate was extracted and reextracted using both modes of operation. Both HETS and HTU were obtained. The aqueous continuous column gave much shorter HTU than the organic continuous column. In reextraction the organic continuous column gave shorter HTU. The Thorex-processes for uranium and thorium co-extraction, co-stripping, and partitioning were studied. Both acid feed solution and acid deficiend feed solution were investigated. The concentration profiles along the column height were obtained. The data were analysed with McCABE-THIELE diagrams to evaluate HETS. (orig./HP) [de

  6. A study of flow performance and flooding in pulsed sieve plate extraction columns

    International Nuclear Information System (INIS)

    Zhang Quanrong; Wang Ruipian

    1986-01-01

    The pulsed sieve plate extraction columns could be divided into two types. The type II which has larger coalescence-damping coefficient K has an apparent transition region that widens when the K value has been increased. In this time, the operation condition in the column of type II is very different from that of type I. The flooding could be divided into three types: the flooding due to insufficient pulsing; emulsion flooding; and flooding due to dispersed phase and continuous phase that replace each other. The three kinds of flooding in the column of type II are very different from that in the column of type I. In the column of type II, when the value of K is about 2 to 3, emulsion flooding has occured and flooding capacity is the largest. In that column. The largest flooding capacity is usually larger than 1300 l/dm 2 · hr when the system 30% TBP(OK)-HNO 3 is used, but it cannot be used under normal conditions when the K value is larger

  7. Capacity limits in columns pulsed with stain steel perforated plates

    International Nuclear Information System (INIS)

    Maset, E.R.; Acosta, E.; Di Piano, M.; Maymo, J.A.

    1987-01-01

    This paper includes part of the second stage of the pulsed columns development program, using a water-nitric acid system as continuous phase and tri-n-butyl phosphate dissolved in kerosene at 30% v/v as disperse phase. Two kits of different geometry perforated plates (different diameter of perforation and free area percentage) were used. Due to the affinity importance of the plates' material with the continuous phase, in all the cases the continuous aqueous phase was used. The relation of flows varied, thus obtaining in each case a curve of characteristic 'flood'. The influence of the geometrical variables, the relation of flows, the medium acidity and the pulse's amplitude was applied in the capacity of the column. Besides, the dimensional correlation of Swift W.H. on the results obtained from 'flood' with both kits of plates to relate flows 1:1 and a minimum deviation was observed. (Author)

  8. Calculation code of mass and heat transfer in a pulsed column for Purex process

    International Nuclear Information System (INIS)

    Tsukada, Takeshi; Takahashi, Keiki

    1993-01-01

    A calculation code for extraction behavior analysis in a pulsed column employed at an extraction process of a reprocessing plant was developed. This code was also combined with our previously developed calculation code for axial temperature profiles in a pulsed column. The one-dimensional dispersion model was employed for both of the extraction behavior analysis and the axial temperature profile analysis. The reported values of the fluid characteristics coefficient, the transfer coefficient and the diffusivities in the pulsed column were used. The calculated concentration profiles of HNO 3 , U and Pu for the steady state have a good agreement with the reported experimental results. The concentration and temperature profiles were calculated under the operation conditions which induce the abnormal U extraction behavior, i.e. U extraction zone is moved to the bottom of the column. Thought there is slight difference between calculated and experimental value, it is appeared that our developed code can be applied to the simulation under the normal operation condition and the relatively slowly transient condition. Pu accumulation phenomena was analyzed with this code and the accumulation tendency is similar to the reported analysis results. (author)

  9. Purex pulse column designs for capacity factor of 3.0 to 3.5

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, G.L.

    1955-04-12

    This memorandum indicates the Purex-Plant pulse-column and pulse- generator revisions which would be required to assure an instantaneous capacity of 25 tons U/day with a 20% capacity safety margin under Purex HW {number_sign}3 Flowsheet conditions. (The use of the Purex HW {number_sign}4 Flowsheet (6) with the revised columns would be expected to increase the capacity to 29 or 30 tons U/day.) The indicated design changes are recorded here for study and for possible reference if need for increased production capacity should arise. No recommendation for adoption at this time is made.

  10. Axial holdup in pulsed perforated-plate column of pulser feeder type, (2)

    International Nuclear Information System (INIS)

    Ikeda, Hidematsu; Suzuki, Atsuyuki; Kiyose, Ryohei.

    1987-01-01

    In mathematical models for a pulsed perforated-plate column, the dispersed phase holdup has been considered to be uniform throughout the length of the column, but fairly recently it is treated as being nonuniform. In the previous paper, the axial holdup data were obtained in the dispersed aqueous and the dispersed organic modes. Experimental results showed that the axial holdup data become nonuniform throughout the column. It was also found that both of the plate type and the operation mode affected the axial holdup distribution. The present work is an attempt to formulate the axial holdup by means of a heuristic selforganization method that provides a nonlinear prediction model of complex system, since the holdup data did not directly show so significant trend as to formulate the axial holdup. The Group Method of Data Handling (GMDH) is used for this purpose. The GMDH can be used for selection and synthesis of input variables concerned with the axial holdup for the pulsed perforated-plate column. The axial holdup data have been successfully correlated and the identification models could be useful in discussing mathematical models. (author)

  11. SLIP VELOCITY IN PULSED DISC AND DOUGHNUT EXTRACTION COLUMN

    Directory of Open Access Journals (Sweden)

    Mohammad Outokesh

    2011-09-01

    Full Text Available In the present work, slip velocity has been measured in a 76 mm diameter pulsed disc and doughnut extraction column for four different liquid-liquid systems. The effects of operating variables including pulsation intensity and dispersed and continuous phase flow rates on slip velocity have been investigated. The existence of three different operational regimes, namely mixersettler, transition, and emulsion regimes, was observed when the energy input was changed. Empirical correlations are derived for prediction of the slip velocity in terms of operating variables, physical properties of the liquid systems, and column geometry for different regimes. Good agreement between prediction and experiments was found for all operating conditions that were investigated.

  12. Laboratory studies of the behavior of undissolved solids in both pulsed and packed column extraction systems

    International Nuclear Information System (INIS)

    Siemer, D.D.

    1989-01-01

    A substantial fraction of the finely divided undissolved solid material found in nuclear fuel reprocessing dissolver-product solutions is hydrophobic and tends to ''seek'' any organic-aqueous interface existing within countercurrent liquid-liquid extraction systems. While passing through pulsed-type columns this material is swept out of the aqueous phase by the combined surface area of the tiny bubbles of dispersed phase. Because these bubbles have a net velocity towards the end of the column where the nominal interface is located, the solids are swept in that direction too. These solids tend to gather in a three-phase ''crud'' layer at the nominal interface point. At equilibrium, about the same amount breaks off from the crud layer and escapes into the liquid exiting from that end of the column as enters it from the other side. If large enough, the crud layer can even interfere with interface detection and control equipment. In packed-column extraction systems, an additional problem is that feed solids can accumulate within the packing material to the point that the column '' floods'' or even totally plugs. The keys to preventing solids-related problems is the correct choice of interface level, and with packed columns, the addition of a ''pulsing leg'' at the bottom of the column. Pulsing packed column systems not only prevents solids from settling onto packing material but it also increses the number of theoretical stages available for extraction. 3 figs., 2 tabs

  13. Airborne 2-Micron Double-Pulsed Integrated Path Differential Absorption Lidar for Column CO2 Measurement

    Science.gov (United States)

    Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta; Refaat, Tamer F.; Remus, Ruben G.; Fay, James J.; Reithmaier, Karl

    2014-01-01

    Double-pulse 2-micron lasers have been demonstrated with energy as high as 600 millijouls and up to 10 Hz repetition rate. The two laser pulses are separated by 200 microseconds and can be tuned and locked separately. Applying double-pulse laser in DIAL system enhances the CO2 measurement capability by increasing the overlap of the sampled volume between the on-line and off-line. To avoid detection complicity, integrated path differential absorption (IPDA) lidar provides higher signal-to-noise ratio measurement compared to conventional range-resolved DIAL. Rather than weak atmospheric scattering returns, IPDA rely on the much stronger hard target returns that is best suited for airborne platforms. In addition, the IPDA technique measures the total integrated column content from the instrument to the hard target but with weighting that can be tuned by the transmitter. Therefore, the transmitter could be tuned to weight the column measurement to the surface for optimum CO2 interaction studies or up to the free troposphere for optimum transport studies. Currently, NASA LaRC is developing and integrating a double-Pulsed 2-micron direct detection IPDA lidar for CO2 column measurement from an airborne platform. The presentation will describe the development of the 2-micron IPDA lidar system and present the airborne measurement of column CO2 and will compare to in-situ measurement for various ground target of different reflectivity.

  14. Effect of pulsed-column-inventory uncertainty on dynamic materials accounting

    International Nuclear Information System (INIS)

    Ostenak, C.A.

    1985-01-01

    Reprocessing plants worldwide use the Purex solvent-extraction process and pulsed-column contactors to separate and purify uranium and plutonium from spent nuclear fuels. The importance of contactor in-process inventory to dynamic materials accounting in reprocessing plants is illustrated using the Allied-General Nuclear Services Plutonium Purification Process (PPP) of the now decommissioned Barnwell Nuclear Fuels Plant. This study shows that (1) good estimates of column inventory are essential for detecting short-term losses of in-process materials, but that (2) input-output (transfer) measurement correlations limit the accounting sensitivity for longer accounting periods (greater than or equal to 1 wk for the PPP). 6 refs., 2 figs., 3 tabs

  15. Use of a pulsed column contactor as a continuous oxalate precipitation reactor

    International Nuclear Information System (INIS)

    Borda, Gilles; Brackx, Emmanuelle; Boisset, Laurence; Duhamet, Jean; Ode, Denis

    2011-01-01

    Research highlights: → A new type of continuous precipitating device was patented by CEA and tested with reaction between a surrogate nitrate cerium(III) or neodymium(III) and oxalate complexing agent. → Precipitate is confined in aqueous phase emulsion in tetrapropylene hydrogen and does not form deposit on the vessel walls. → Measure size of the precipitate ranges from 20 to 40 μm, it meets the process requirements to filter, and the precipitation reaction is complete. → The laboratory design can be extrapolated to an industrial uranium(IV) and minor actinide(III) coprecipitating column. - Abstract: The current objective of coprecipitating uranium, and minor actinides in order to fabricate a new nuclear fuel by direct (co)precipitation for further transmutation, requires to develop specific technology in order to meet the following requirements: nuclear maintenance, criticity, and potentially high flowrates due to global coprecipitation. A new type of device designed and patented by the CEA was then tested in 2007 under inactive conditions and with uranium. The patent is for organic confinement in a pulsed column (PC). Actually, pulsed columns have been working for a long time in a nuclear environment, as they allow high capacity, sub-critical design (annular geometry) and easy high activity maintenance. The precipitation reaction between the oxalate complexing agent and a surrogate nitrate - cerium(III) or neodymium(III) alone, or coprecipitated uranium(IV) and cerium(III) - occurs within an emulsion created in the device by these two phases flowing with a counter-current chemically inert organic phase (for example tetrapropylene hydrogen-TPH) produced by the stirring action of the column pulsator. The precipitate is confined and thus does not form deposits on the vessel walls (which are also water-repellent); it flows downward by gravity and exits the column continuously into a settling tank. The results obtained for precipitation of cerium or

  16. Study on automatic control of high uranium concentration solvent extraction with pulse sieve-plate column

    International Nuclear Information System (INIS)

    You Wenzhi; Xing Guangxuan; Long Maoxiong; Zhang Jianmin; Zhou Qin; Chen Fuping; Ye Lingfeng

    1998-01-01

    The author mainly described the working condition of the automatic control system of high uranium concentration solvent extraction with pulse sieve-plate column on a large scale test. The use of the automatic instrument and meter, automatic control circuit, and the best feedback control point of the solvent extraction processing with pulse sieve-plate column are discussed in detail. The writers point out the success of this experiment on automation, also present some questions that should be cared for the automatic control, instruments and meters in production in the future

  17. Use of a pulsed column with discs and crowns for uranium extraction from phosphoric acid

    International Nuclear Information System (INIS)

    1982-04-01

    The physico-chemistry of the system phosphoric acid-uranium-dioctylpyrophosphoric acid is studied for the determination of analytical methods and extraction parameters (oxidation state of uranium and iron, phosphorus concentration, extractant concentration). Extraction is then realized on a pilot scale with a liquid-liquid extraction column 4m high and of 50 mm in diameter with a column packing made of discs and crowns. Column efficiency is evaluated by studying uranium transfer as a function of operating conditions. The results obtained are extrapolated to an industrial scale and a comparative economic evaluation is made between a pulsed column and a mixer-settler [fr

  18. Simulation and control synthesis for a pulse column separation system for plutonium--uranium recovery

    International Nuclear Information System (INIS)

    McCutcheon, E.B.

    1975-05-01

    Control of a plutonium-uranium partitioning column was studied using a mathematical model developed to simulate the dynamic response and to test postulated separation mechanisms. The column is part of a plutonium recycle flowsheet developed for the recovery of plutonium and uranium from metallurgical scrap. In the first step of the process, decontamination from impurities is achieved by coextracting plutonium and uranium in their higher oxidation states. In the second step, reduction of the plutonium to a lower oxidation state allows partitioning of the plutonium and uranium. The use of hydroxylamine for the plutonium reduction in this partitioning column is a unique feature of the process. The extraction operations are carried out in pulse columns. (U.S.)

  19. Extreme degree of ionization in homogenous micro-capillary plasma columns heated by ultrafast current pulses.

    Science.gov (United States)

    Avaria, G; Grisham, M; Li, J; Tomasel, F G; Shlyaptsev, V N; Busquet, M; Woolston, M; Rocca, J J

    2015-03-06

    Homogeneous plasma columns with ionization levels typical of megaampere discharges are created by rapidly heating gas-filled 520-μm-diameter channels with nanosecond rise time current pulses of 40 kA. Current densities of up to 0.3  GA cm^{-2} greatly increase Joule heating with respect to conventional capillary discharge Z pinches, reaching unprecedented degrees of ionization for a high-Z plasma column heated by a current pulse of remarkably low amplitude. Dense xenon plasmas are ionized to Xe^{28+}, while xenon impurities in hydrogen discharges reach Xe^{30+}. The unique characteristics of these hot, ∼300:1 length-to-diameter aspect ratio plasmas allow the observation of unexpected spectroscopic phenomena. Axial spectra show the unusual dominance of the intercombination line over the resonance line of He-like Al by nearly an order of magnitude, caused by differences in opacities in the axial and radial directions. These plasma columns could enable the development of sub-10-nm x-ray lasers.

  20. Operating range, hold-up, droplet size and axial mixing of pulsed plate columns in highly disperse and low-continuity volume flows

    International Nuclear Information System (INIS)

    Schmidt, H.; Miller, H.

    Operating behavior, hold-up, droplet size and axial mixing are investigated in highly disperse and slightly continuous volume flows in a pulsed plate column. The geometry of the column of 4-m length and 10-cm inside diameter was held constant. The hole shape of the column bases was changed, wherby the cylindrical, sharp-edge drilled hole is compared with the punched, nozzle-shaped hole in their effects on the fluid-dynamic behavior. In this case we varied the volume flows, the ratio of volume flows, the pulse frequency and the operating temperature. The operation was held constant for the aqueous, the organic, the continuous and the disperse phases. The objective was to demonstrate the applicability of pulsed plate columns with very large differences between the organic disperse and the aqueous continuous volume flow, to obtain design data for such columns and to perform a scale-up to industrial reprocessing plant-size. 18 references, 11 figures, 3 tables

  1. Studies on the hydrodynamic properties of the sieve plate pulsed column for 30% TRPO-kerosene/nitric acid system

    International Nuclear Information System (INIS)

    Ma Ronglin; Chen Jing; Xu Shiping; Wu Qiulin; Tai Derong; Song Chongli

    2000-01-01

    The hydrodynamic properties of the sieve plate pulsed column for 30% TRPO-kerosene/nitric acid system is studied. With the organic phase or aqueous phase as the continuous one, the dispersed phase behaves mainly as coalescing or dispersing, respectively. The sieve plate pulsed column has a fairish flooding throughput for this system. Under the same pulsation intensity, the flooding throughput for the organic phase as the continuous one is more than that for the aqueous phase as the continuous one

  2. Studies on the wetting properties of plate surfaces used in pulsed extraction columns

    International Nuclear Information System (INIS)

    Tai Derong; Yang Xin; Wang Xinchang

    1991-01-01

    Many factors influence the hydrodynamic characteristics of pulsed column. Of all the factors the surface effect at liquid-liquid interfaces and liquid-solid boundaries may be the most influential factor to the state of droplets. In order to get some understanding of the behaviour of droplets in a pulsed column, the time history of wetting properties of plates under different conditions in 30% TBP (Kerosene) -HNO 3 -UO 2 (NO 3 ) 2 -H 2 O systems was studied. The results show that the hydrophilic wetting behaviour of the plates changes into the hydrophobic and neutral conditions, respectively after they have been exposed to air and put in the 'open system' within about 50 days after contacting with process solutions. For the case where the access of air is prohibited at the upper organic phase boundary by a well fitting cover, or supersonic pulse cleaning is used to the cartridge, the behaviour of the metal surface stays in the original good hydrophilic wetting condition constant with time. The uranium charged liquid systems can conserve hydrophilic behaviour better than the non-charged systems under identical conditions. It is also found that the interfacial tension is unvaried with time for saturated process systems, hence it has no effects on the variation of wettability

  3. Comparison of the performance of full scale pulsed columns vs. mixer-settlers for uranium solvent extraction

    International Nuclear Information System (INIS)

    Movsowitz, R.L.; Kleinberger, R.; Buchalter, E.M.; Grinbaum, B.

    2000-01-01

    A rare opportunity arose to compare the performance of Bateman Pulsed Columns (BPC) vs. Mixer-Settlers at an industrial site, over a long period, when the Uranium Solvent Extraction Plant of WMC at Olympic Dam, South Australia was upgraded. The original plant was operated for years with two trains of 2-stage mixer-settler batteries for the extraction of uranium. When the company decided to increase the yield of the plant, the existing two trains of mixer-settlers for uranium extraction were arranged in series, giving one 4-stage battery. In parallel, two Bateman Pulsed Columns, of the disc-and-doughnut type, were installed to compare the performance of both types of equipment over an extended period.The plant has been operating in parallel for three years and the results show that the performance of the columns is excellent: the extraction yield is similar to the 4 mixer-settlers in series - about 98%, the entrainment of solvent is lower, there are less mechanical failures, less problems with crud, smaller solvent losses and the operation is simpler. The results convinced WMC to install an additional 10 BPC's for the expansion of their uranium plant. These columns were successfully commissioned early 1999. This paper includes quantitative comparison of both types of equipment. (author)

  4. Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique.

    Science.gov (United States)

    Ghiyas Ud Din; Imran Rafiq Chughtai; Hameed Inayat, Mansoor; Hussain Khan, Iqbal

    2009-01-01

    Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and (99m)Tc in the form of sodium pertechnetate eluted from a (99)Mo/(99m)Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer (99m)Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.

  5. Study of axial mixing, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column using radiotracer technique

    International Nuclear Information System (INIS)

    Ghiyas Ud Din; Imran Rafiq Chughtai; Mansoor Hameed Inayat; Iqbal Hussain Khan

    2009-01-01

    Axial mixing, holdup and slip velocity of dispersed phase which are parameters of fundamental importance in the design and operation of liquid-liquid extraction pulsed sieve plate columns have been investigated. Experiments for residence time distribution (RTD) analysis have been carried out for a range of pulsation frequency and amplitude in a liquid-liquid extraction pulsed sieve plate column with water as dispersed and kerosene as continuous phase using radiotracer technique. The column was operated in emulsion region and 99m Tc in the form of sodium pertechnetate eluted from a 99 Mo/ 99m Tc generator was used to trace the dispersed phase. Axial dispersed plug flow model with open-open boundary condition and two points measurement method was used to simulate the hydrodynamics of dispersed phase. It has been observed that the axial mixing and holdup of dispersed phase increases with increase in pulsation frequency and amplitude until a maximum value is achieved while slip velocity decreases with increase in pulsation frequency and amplitude until it approaches a minimum value. Short lived and low energy radiotracer 99m Tc in the form of sodium pertechnetate was found to be a good water tracer to study the hydrodynamics of a liquid-liquid extraction pulsed sieve plate column operating with two immiscible liquids, water and kerosene. Axial dispersed plug flow model with open-open boundary condition was found to be a suitable model to describe the hydrodynamics of dispersed phase in the pulsed sieve plate extraction column.

  6. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  7. A study of pulsed sieve-plate column for Th-U extraction separation process: Pt. 3

    International Nuclear Information System (INIS)

    An Yanjun; Tong Jihong; Ma Xuquan; Tai Derong

    1993-01-01

    In 50 mm diameter pulsed sieve-plate column, the mass transfer process of the Th-U low decontaminate cycle process was described by diffusion model. The model parameters of axial mixing coefficient and mass transfer coefficient were determined simultaneously and directly from concentration profile by the complex optimum method. The calculated values of concentration profile are in accordance with the experimental values. The results show that when aqueous phase is continuous in Thorex process pulsed sieve-plate column two phases axial mixing is approach, and when organic phase is continuous the axial mixing of dispersion phase is less one of continuous phase. By use of complex optimum method, many shortcomings are overcome, such as the difference between calculating and experimental results due to the selection of some unadvisable methods and easy flowing-out of computer program, etc.. This method is simple and reliable, and convergence is quicker

  8. Design of pulsed perforated-plate columns for industrial scale mass transfer applications - present experience and the need for a model based approach

    International Nuclear Information System (INIS)

    Roy, Amitava

    2010-01-01

    Mass transfer is a vital unit operation in the processing of spent nuclear fuel in the backend of closed fuel cycle and Pulsed perforated plate extraction columns are used as mass transfer device for more than five decades. The pulsed perforated plate column is an agitated differential contactor, which has wide applicability due to its simplicity, high mass transfer efficiency, high through put, suitability for maintenance free remote operation, ease of cleaning/decontamination and cost effectiveness. Design of pulsed columns are based on a model proposed to describe the hydrodynamics and mass transfer. In equilibrium stage model, the HETS values are obtained from pilot plant experiments and then scaled empirically to design columns for industrial application. The dispersion model accounts for mass transfer kinetics and back-mixing. The drop population balance model can describe complex hydrodynamics of dispersed phase, that is, drop formation, break-up and drop-to-drop interactions. In recent years, significant progress has been made to model pulsed columns using CFD, which provides complete mathematical description of hydrodynamics in terms of spatial distribution of flow fields and 3D visualization. Under the condition of pulsation, the poly-dispersed nature of turbulent droplet swarm renders modeling difficult. In the absence of industry acceptance of proposed models, the conventional chemical engineering practice is to use HETS-NTS concept or HTU-NTU approach to design extraction columns. The practicability of HTU-NTU approach has some limitations due to the lack of experimental data on individual film mass transfer coefficients. Presently, the HETS-NTS concept has been used for designing the columns, which has given satisfactory performance. The design objective is mainly to arrive at the diameter and height of the mass transfer section for a specific plate geometry, fluid properties and pulsing condition to meet the intended throughput (capacity) and mass

  9. Column CO2 Measurement From an Airborne Solid-State Double-Pulsed 2-Micron Integrated Path Differential Absorption Lidar

    Science.gov (United States)

    Singh, U. N.; Yu, J.; Petros, M.; Refaat, T. F.; Remus, R.; Fay, J.; Reithmaier, K.

    2014-01-01

    NASA LaRC is developing and integrating a double-Pulsed 2-micron direct detection IPDA lidar for CO2 column measurement from an airborne platform. The presentation will describe the development of the 2-micrometers IPDA lidar system and present the airborne measurement of column CO2 and will compare to in-situ measurement for various ground target of different reflectivity.

  10. Analysis of the Conditions for the Inception of Natural Pulsing Flow in Cocurrent Packed Columns

    Czech Academy of Sciences Publication Activity Database

    Akramov, T. A.; Stavárek, Petr; Jiřičný, Vladimír; Staněk, Vladimír

    2008-01-01

    Roč. 47, č. 19 (2008), s. 7424-7432 ISSN 0888-5885 R&D Projects: GA MPO FT-TA/039 Institutional research plan: CEZ:AV0Z40720504 Keywords : natural pulsing flow * cocurrent flow * packed columns Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.895, year: 2008

  11. Validation of the design of small diameter pulsed columns for the process line DRA. Tests reliability compared with the industrial scale

    International Nuclear Information System (INIS)

    Leybros, J.

    2000-01-01

    As part of the Spin program related to the management of nuclear wastes, studies have been undertaken to develop partitioning processes like Diamex process. The process line CCBP/DRA in Atalante facility forms one of the main equipment devoted to these studies. On this line industrial apparatus are used but some like pulsed columns need to be adapted because of the specificity of the installation: limiting amount of nuclear matter, gaseous waste minimization, safety, limiting amounts of new extractants,... This article presents the comparison of 2 air pulsed columns, one with a standard diameter of 25 (DN25), the other with a reduced diameter of 15 (DN15). This comparison is based on 3 main criteria: pulsation capability, superficial throughput and mass transfer efficiency. The overall comparison shows that a DN15 pulsed column can be considered as a representative tool of research and development. Particularly, the study demonstrates the possibility of scaling up the results

  12. Simulation of emulsion copolymerization reactions in a continuous pulsed sieve-plate column reactor

    OpenAIRE

    C. Sayer; R. Giudici

    2004-01-01

    This work addressed the viability of using a pulsed sieve-plate column reactor to carry out continuous vinyl acetate/butyl acrylate emulsion copolymerization reactions. A rigorous mathematical model of emulsion copolymerization reactions in a tubular reactor with axial dispersion was used for this purpose. Operational conditions were defined to attain high monomer conversions at the reactor outlet in a relatively short residence time and, at the same time, produce a copolymer with a more homo...

  13. Development of a positive column pulsed capillary discharge source for use with high resolution Fourier transform spectrometer

    International Nuclear Information System (INIS)

    Syed, W A A

    2002-01-01

    We report the designing and application of a positive column pulsed capillary discharge with the Fourier transform spectrometer (FTS). The pulsed light source has been used for the first time with the ultraviolet FTS. The experiment has been carried out with the high energy pulsed discharge with energy of 2-3 J lasting about 300 ns. A system has been developed to trigger the discharge at about 600 Hz with the pulses directly taken from the FTS sampling system. The spectrum of Ar III has been recorded in the 19 000-50 000 cm -1 region with good signal to noise ratio. The results have opened a wide range of applications in spectroscopy of multiply ionized species

  14. Description of design and operating procedures of small scale pulsed columns for experimental study on extraction process under abnormal conditions

    International Nuclear Information System (INIS)

    Wakamatsu, Sachio; Sato, Makoto; Kubo, Nobuo; Sakurai, Satoshi; Ami, Norio

    1990-09-01

    To study transient phenomena in a pulsed column co-decontamination process under abnormal conditions, a pair of small scale pulsed columns (effective extraction section; I.D: 25 mm, H.: 2260 mm) for extraction and scrub were installed in the laboratory. An evaporator of aqueous uranium solution was also equipped to reuse concentrated solution as the feed. This report describes several items to have been carefully treated in design, specification and operating procedure of the apparatuses for the experiments. Also described are the procedures for preparation of the feed solutions and treatments of the solutions after the experiments; back-extraction of uranium, diluent washing, alkaline washing and concentration of uranium solution. (author)

  15. Simulation of emulsion copolymerization reactions in a continuous pulsed sieve-plate column reactor

    Directory of Open Access Journals (Sweden)

    Sayer C.

    2004-01-01

    Full Text Available This work addressed the viability of using a pulsed sieve-plate column reactor to carry out continuous vinyl acetate/butyl acrylate emulsion copolymerization reactions. A rigorous mathematical model of emulsion copolymerization reactions in a tubular reactor with axial dispersion was used for this purpose. Operational conditions were defined to attain high monomer conversions at the reactor outlet in a relatively short residence time and, at the same time, produce a copolymer with a more homogeneous composition.

  16. Pulsed Airborne Lidar Measurements of C02 Column Absorption

    Science.gov (United States)

    Abshire, James B.; Riris, Haris; Allan, Graham R.; Weaver, Clark J.; Mao, Jianping; Sun, Xiaoli; Hasselbrack, William E.; Rodriquez, Michael; Browell, Edward V.

    2011-01-01

    We report on airborne lidar measurements of atmospheric CO2 column density for an approach being developed as a candidate for NASA's ASCENDS mission. It uses a pulsed dual-wavelength lidar measurement based on the integrated path differential absorption (IPDA) technique. We demonstrated the approach using the CO2 measurement from aircraft in July and August 2009 over four locations. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The 2009 measurements have been analyzed in detail and the results show approx.1 ppm random errors for 8-10 km altitudes and approx.30 sec averaging times. Airborne measurements were also made in 2010 with stronger signals and initial analysis shows approx. 0.3 ppm random errors for 80 sec averaging times for measurements at altitudes> 6 km.

  17. Study and modeling of the dispersed phase behavior in a pulsed column: application to an oxalic precipitation process

    International Nuclear Information System (INIS)

    Amokrane, Abdenour

    2014-01-01

    The thesis focuses on the study and modeling of a pulsed column used in liquid-liquid extraction operations in the nuclear industry and which is otherwise considered for continuous precipitation operations in emulsion. Modeling the behavior of the dispersed phase in the column is undertaken in this manuscript. First, we began by modeling the continuous phase mean velocity and turbulence fields, which are responsible for transport, breakage and coalescence of the drops. The model developed, validated by PIV measurements, predicts turbulence in a satisfying way. Modeling the residence time distribution (RTD) of the drops by a Lagrangian approach is then achieved. This model is validated on measurements taken by a shadow-graph technique. The simulation results are in good agreement with the experimental ones. To model the droplet size distributions (DSD) in the column, we used the population balance equations (PBE) that we have coupled with the computational fluid dynamics equations (CFD). A continuously stirred tank reactor (CSTR) with an optical sensor is used, at first, to acquire the DSD representative of our liquid-liquid system. Through a 0D modeling of the flow in the CSTR, and solving the inverse problem, we have determined the breakage and coalescence kernels relevant for our system, to be used in the PBE. These kernels were then used to predict the DSD in the pulsed column by a coupled CFD-PBE model based on the QMOM method. Finally, a validation of the coupled CFD-PBE model is made from DSD in good agreement with the experimental data both qualitatively and quantitatively. The validated model is then used to study the emulsion sensitivity to the column operating conditions. (author) [fr

  18. Laser surface wakefield in a plasma column

    International Nuclear Information System (INIS)

    Gorbunov, L.M.; Mora, P.; Ramazashvili, R.R.

    2003-01-01

    The structure of the wakefield in a plasma column, produced by a short intense laser pulse, propagating through a gas affected by tunneling ionization is investigated. It is shown that besides the usual plasma waves in the bulk part of the plasma column [see Andreev et al., Phys. Plasmas 9, 3999 (2002)], the laser pulse also generates electromagnetic surface waves propagating along the column boundary. The length of the surface wake wave substantially exceeds the length of the plasma wake wave and its electromagnetic field extends far outside the plasma column

  19. Contribution to the study of wettability in a pulsed column dedicated to the production of a precipitate

    International Nuclear Information System (INIS)

    Picard, R.

    2011-01-01

    The process dedicated to the oxalic precipitation of plutonium is very sensitive to the high sticking behavior of the produced precipitates. Therefore, the laboratory of 'Genie Chimique et Instrumentation' based in Marcoule in France puts forward the idea of carrying out the process in a pulsed column. In this way, the precipitate is confined inside in the droplets of the emulsion, far from the surfaces of the apparatus. Nevertheless, if those surfaces are made of stainless steel, the fouling of the column is inevitably observed. The thesis also introduces the concepts and tools dedicated to a fine understanding of the fouling issue. Though the work carried out scans the whole issue, the thesis mainly focuses on drop bouncing. The results provide experimental data in a low studied configuration and target the key parameters driving the bounce. The practical applications of those results point out that using an un-optimized stainless steel pulsed column for the precipitation of radionuclides does not prevent from fouling. The process could still be carried out using another technology patented during the PhD. This last point needs more investigations. Especially, the CEA has to work on the scale-up steps to design an apparatus which could be able to process industrial flow rates. Besides, this might be an interesting issue in process engineering. (author) [fr

  20. Measurement of atmospheric CO2 column concentrations to cloud tops with a pulsed multi-wavelength airborne lidar

    Science.gov (United States)

    Mao, Jianping; Ramanathan, Anand; Abshire, James B.; Kawa, Stephan R.; Riris, Haris; Allan, Graham R.; Rodriguez, Michael; Hasselbrack, William E.; Sun, Xiaoli; Numata, Kenji; Chen, Jeff; Choi, Yonghoon; Yang, Mei Ying Melissa

    2018-01-01

    We have measured the column-averaged atmospheric CO2 mixing ratio to a variety of cloud tops by using an airborne pulsed multi-wavelength integrated-path differential absorption (IPDA) lidar. Airborne measurements were made at altitudes up to 13 km during the 2011, 2013 and 2014 NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) science campaigns flown in the United States West and Midwest and were compared to those from an in situ sensor. Analysis of the lidar backscatter profiles shows the average cloud top reflectance was ˜ 5 % for the CO2 measurement at 1572.335 nm except to cirrus clouds, which had lower reflectance. The energies for 1 µs wide laser pulses reflected from cloud tops were sufficient to allow clear identification of CO2 absorption line shape and then to allow retrievals of atmospheric column CO2 from the aircraft to cloud tops more than 90 % of the time. Retrievals from the CO2 measurements to cloud tops had minimal bias but larger standard deviations when compared to those made to the ground, depending on cloud top roughness and reflectance. The measurements show this new capability helps resolve CO2 horizontal and vertical gradients in the atmosphere. When used with nearby full-column measurements to ground, the CO2 measurements to cloud tops can be used to estimate the partial-column CO2 concentration below clouds, which should lead to better estimates of surface carbon sources and sinks. This additional capability of the range-resolved CO2 IPDA lidar technique provides a new benefit for studying the carbon cycle in future airborne and space-based CO2 missions.

  1. Measurement of Atmospheric CO2 Column Concentrations to Cloud Tops With a Pulsed Multi-Wavelength Airborne Lidar

    Science.gov (United States)

    Mao, Jianping; Ramanathan, Anand; Abshire, James B.; Kawa, Stephan R.; Riris, Haris; Allan, Graham R.; Rodriguez, Michael R.; Hasselbrack, William E.; Sun, Xiaoli; Numata, Kenji; hide

    2018-01-01

    We have measured the column-averaged atmospheric CO2 mixing ratio to a variety of cloud tops by using an airborne pulsed multi-wavelength integrated-path differential absorption (IPDA) lidar. Airborne measurements were made at altitudes up to 13 km during the 2011, 2013 and 2014 NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) science campaigns flown in the United States West and Midwest and were compared to those from an in situ sensor. Analysis of the lidar backscatter profiles shows the average cloud top reflectance was approx. 5% for the CO2 measurement at 1572.335 nm except to cirrus clouds, which had lower reflectance. The energies for 1 micro-s wide laser pulses reflected from cloud tops were sufficient to allow clear identification of CO2 absorption line shape and then to allow retrievals of atmospheric column CO2 from the aircraft to cloud tops more than 90% of the time. Retrievals from the CO2 measurements to cloud tops had minimal bias but larger standard deviations when compared to those made to the ground, depending on cloud top roughness and reflectance. The measurements show this new capability helps resolve CO2 horizontal and vertical gradients in the atmosphere. When used with nearby full-column measurements to ground, the CO2 measurements to cloud tops can be used to estimate the partial-column CO2 concentration below clouds, which should lead to better estimates of surface carbon sources and sinks. This additional capability of the range-resolved CO2 IPDA lidar technique provides a new benefit for studying the carbon cycle in future airborne and space-based CO2 missions.

  2. Measurement of atmospheric CO2 column concentrations to cloud tops with a pulsed multi-wavelength airborne lidar

    Directory of Open Access Journals (Sweden)

    J. Mao

    2018-01-01

    Full Text Available We have measured the column-averaged atmospheric CO2 mixing ratio to a variety of cloud tops by using an airborne pulsed multi-wavelength integrated-path differential absorption (IPDA lidar. Airborne measurements were made at altitudes up to 13 km during the 2011, 2013 and 2014 NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS science campaigns flown in the United States West and Midwest and were compared to those from an in situ sensor. Analysis of the lidar backscatter profiles shows the average cloud top reflectance was ∼ 5 % for the CO2 measurement at 1572.335 nm except to cirrus clouds, which had lower reflectance. The energies for 1 µs wide laser pulses reflected from cloud tops were sufficient to allow clear identification of CO2 absorption line shape and then to allow retrievals of atmospheric column CO2 from the aircraft to cloud tops more than 90 % of the time. Retrievals from the CO2 measurements to cloud tops had minimal bias but larger standard deviations when compared to those made to the ground, depending on cloud top roughness and reflectance. The measurements show this new capability helps resolve CO2 horizontal and vertical gradients in the atmosphere. When used with nearby full-column measurements to ground, the CO2 measurements to cloud tops can be used to estimate the partial-column CO2 concentration below clouds, which should lead to better estimates of surface carbon sources and sinks. This additional capability of the range-resolved CO2 IPDA lidar technique provides a new benefit for studying the carbon cycle in future airborne and space-based CO2 missions.

  3. Parameters measurement for the thermal neutron beam in the thermal column hole of Xi’an pulse reactor

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The distribution of the neutron spectra in the thermal column hole of Xi’an pulse reactor was measured with the time-of-flight method.Compared with the thermal Maxwellian theory neutron spectra,the thermal neutron spectra measured is a little softer,and the average neutron energy of the experimental spectra is about 0.042±0.01 eV.The thermal neutron fluence rate at the front end of thermal column hole,measured with gold foil activation techniques,is about 1.18×105 cm-2 s-1.The standard uncertainty of the measured thermal neutron fluence is about 3%.The spectra-averaged cross section of 197Au(n,γ) determined by the experimental thermal neutron spectra is(92.8±0.93) ×10-24 cm2.

  4. Solvent extraction columns

    International Nuclear Information System (INIS)

    Middleton, P.; Smith, J.R.

    1979-01-01

    In pulsed columns for use in solvent extraction processes, e.g. the reprocessing of nuclear fuel, the horizontal perforated plates inside the column are separated by interplate spacers manufactured from metallic neutron absorbing material. The spacer may be in the form of a spiral or concentric circles separated by radial limbs, or may be of egg-box construction. Suitable neutron absorbing materials include stainless steel containing boron or gadolinium, hafnium metal or alloys of hafnium. (UK)

  5. Computer Simulation of Global Profiles of Carbon Dioxide Using a Pulsed, 2-Micron, Coherent-Detection, Column-Content DIAL System

    Science.gov (United States)

    Kavaya, Michael J.; Singh, Upendra N.; Koch, Grady J.; Yu, Jirong; Frehlich, Rod G.

    2009-01-01

    We present preliminary results of computer simulations of the error in measuring carbon dioxide mixing ratio profiles from earth orbit. The simulated sensor is a pulsed, 2-micron, coherent-detection lidar alternately operating on at least two wavelengths. The simulated geometry is a nadir viewing lidar measuring the column content signal. Atmospheric absorption is modeled using FASCODE3P software with the HITRAN 2004 absorption line data base. Lidar shot accumulation is employed up to the horizontal resolution limit. Horizontal resolutions of 50, 100, and 200 km are shown. Assuming a 400 km spacecraft orbit, the horizontal resolutions correspond to measurement times of about 7, 14, and 28 s. We simulate laser pulse-pair repetition frequencies from 1 Hz to 100 kHz. The range of shot accumulation is 7 to 2.8 million pulse-pairs. The resultant error is shown as a function of horizontal resolution, laser pulse-pair repetition frequency, and laser pulse energy. The effect of different on and off pulse energies is explored. The results are compared to simulation results of others and to demonstrated 2-micron operating points at NASA Langley.

  6. Pulsing flow in trickle bed columns

    NARCIS (Netherlands)

    Blok, Jan Rudolf

    1981-01-01

    In the operation of a packed column with cocurrent downflow of gas and liquid (trickle bed) several flowpatterns can be observed depending on the degree of interaction between gas and liquid. At low liquid and gas flow rates - low interaction - gascontinuous flow occurs. In this flowregime, the

  7. LIQUID-LIQUID EXTRACTION COLUMNS

    Science.gov (United States)

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  8. Airborne Measurements of CO2 Column Absorption and Range Using a Pulsed Direct-Detection Integrated Path Differential Absorption Lidar

    Science.gov (United States)

    Abshire, James B.; Riris, Haris; Weaver, Clark J.; Mao, Jianping; Allan, Graham R.; Hasselbrack, William E.; Browell, Edward V.

    2013-01-01

    We report on airborne CO2 column absorption measurements made in 2009 with a pulsed direct-detection lidar operating at 1572.33 nm and utilizing the integrated path differential absorption technique. We demonstrated these at different altitudes from an aircraft in July and August in flights over four locations in the central and eastern United States. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The lidar measurement statistics were also calculated for each flight as a function of altitude. The optical depth varied nearly linearly with altitude, consistent with calculations based on atmospheric models. The scatter in the optical depth measurements varied with aircraft altitude as expected, and the median measurement precisions for the column varied from 0.9 to 1.2 ppm. The altitude range with the lowest scatter was 810 km, and the majority of measurements for the column within it had precisions between 0.2 and 0.9 ppm.

  9. Airborne Measurements of CO2 Column Concentration and Range Using a Pulsed Direct-Detection IPDA Lidar

    Science.gov (United States)

    Abshire, James B.; Ramanathan, Anand; Riris, Haris; Mao, Jianping; Allan, Graham R.; Hasselbrack, William E.; Weaver, Clark J.; Browell, Edward V.

    2013-01-01

    We have previously demonstrated a pulsed direct detection IPDA lidar to measure range and the column concentration of atmospheric CO2. The lidar measures the atmospheric backscatter profiles and samples the shape of the 1,572.33 nm CO2 absorption line. We participated in the ASCENDS science flights on the NASA DC-8 aircraft during August 2011 and report here lidar measurements made on four flights over a variety of surface and cloud conditions near the US. These included over a stratus cloud deck over the Pacific Ocean, to a dry lake bed surrounded by mountains in Nevada, to a desert area with a coal-fired power plant, and from the Rocky Mountains to Iowa, with segments with both cumulus and cirrus clouds. Most flights were to altitudes >12 km and had 5-6 altitude steps. Analyses show the retrievals of lidar range, CO2 column absorption, and CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds, between cumulus clouds, and to stratus cloud tops. The retrievals shows the decrease in column CO2 due to growing vegetation when flying over Iowa cropland as well as a sudden increase in CO2 concentration near a coal-fired power plant. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption lineshape (averaged for 50 s) matched the predicted shapes to better than 1% RMS error. For 10 s averaging, the scatter in the retrievals was typically 2-3 ppm and was limited by the received signal photon count. Retrievals were made using atmospheric parameters from both an atmospheric model and from in situ temperature and pressure from the aircraft. The retrievals had no free parameters and did not use empirical adjustments, and >70% of the measurements passed screening and were used in analysis. The differences between the lidar-measured retrievals and in situ measured average CO2 column concentrations were 6 km.

  10. Space-time evolution of the power absorbed by creating and heating a hydrogen plasma column by a pulsed laser beam

    International Nuclear Information System (INIS)

    Pincosy, Philip; Dufresne, Daniel; Bournot, Philippe; Caressa, J.-P.; Autric, Michel

    1976-01-01

    Space-time measurements of light intensity are presented for the analysis of the processes involved in the creation and heating of an under-dense hydrogen plasma column by a pulsed CO 2 laser beam. The laser beam trapping due to the rapid development of a radial electron density gradient is specifically demonstrated. Time measurements of the changes in the laser power longitudinally transmitted through the plasma give evidence for a significant absorption of the incident power during the first 150 nanoseconds of the interaction [fr

  11. Nondestructive evaluation of the preservation state of stone columns in the Hospital Real of Granada

    Science.gov (United States)

    Moreno de Jong van Coevorden, C.; Cobos Sánchez, C.; Rubio Bretones, A.; Fernández Pantoja, M.; García, Salvador G.; Gómez Martín, R.

    2012-12-01

    This paper describes the results of the employment of two nondestructive evaluation methods for the diagnostic of the preservation state of stone elements. The first method is based on ultrasonic (US) pulses while the second method uses short electromagnetic pulses. Specifically, these methods were applied to some columns, some of them previously restored. These columns are part of the architectonic heritage of the University of Granada, in particular they are located at the patio de la capilla del Hospital Real of Granada. The objective of this work was the application of systems based on US pulses (in transmission mode) and the ground-penetrating radar systems (electromagnetic tomography) in the diagnosis and detection of possible faults in the interior of columns.

  12. Using a Solid State Switch for a 60kV Bouncer to Control Energy Spread during the Beam Pulse*

    CERN Document Server

    Donley, L; McMichael, G E; Stipp, V F

    2004-01-01

    The beam injected into the IPNS Linac is from a column utilizing a Cockcroft-Walton voltage source. The accelerating column consists of a single high gradient gap. To lessen the likelihood of gap voltage breakdown, we pulse (“bounce”) the column voltage up during the beam pulse allowing the column DC voltage to be lower. The accelerating voltage is supplied through a 5 MΩ resistor and has only small capacitance to hold the voltage constant during the beam pulse. A capacitor is connected between the high voltage end of the column and the bouncer pulse generator. The bouncer pulse increases the column voltage to the proper level just microseconds before the beam pulse. A slope on the top of the bouncer pulse allows for correction to be added, compensating for the voltage droop that results from beam loading. The bouncer that has served this purpose in the past utilized a tube amplifier. In searching for a suitable replacement system it was decided that the system should be able to ...

  13. CO2-laser--produced plasma columns in a solenoidal magnetic field

    International Nuclear Information System (INIS)

    Offenberger, A.A.; Cervenan, M.R.; Smy, P.R.

    1976-01-01

    A 1-GW CO 2 laser pulse has been used to produce extended column breakdown of hydrogen at low pressure in a 20-cm-long solenoid. Magnetic fields of up to 110 kG were used to inhibit radial losses of the plasma column. A differential pumping scheme was devised to prevent formation of an opaque absorption wave travelling out of the solenoid back toward the focusing lens. Target burns give direct evidence for trapped laser beam propagation along the plasma column

  14. Guiding of laser pulses in plasma waveguides created by linearly-polarized femtosecond laser pulses

    OpenAIRE

    Lemos, N.; Cardoso, L.; Geada, J.; Figueira, G.; Albert, F.; Dias, J. M.

    2018-01-01

    We experimentally demonstrate that plasma waveguides produced with ultra-short laser pulses (sub-picosecond) in gas jets are capable of guiding high intensity laser pulses. This scheme has the unique ability of guiding a high-intensity laser pulse in a plasma waveguide created by the same laser system in the very simple and stable experimental setup. A hot plasma column was created by a femtosecond class laser that expands into an on-axis parabolic low density profile suitable to act as a wav...

  15. Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption and Range During the ASCENDS 2009-2011 Airborne Campaigns

    Science.gov (United States)

    Abshire, J. B.; Weaver, C. J.; Riris, H.; Mao, J.; Sun, X.; Allan, G. R.; Hasselbrack, W. E.; Browell, E. V.

    2012-01-01

    We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission and have demonstrated the CO2 and O2 measurements from aircraft. Our technique uses two pulsed lasers allowing simultaneous measurement of a single CO2 absorption line near 1572 nm, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are stepped in wavelength across the CO2 line and an O2 line doublet during the measurement. The column densities for the CO2 and O2 are estimated from the differential optical depths (DOD) of the scanned absorption lines via the IPDA technique. For the 2009 ASCENDS campaign we flew the CO2 lidar only on a Lear-25 aircraft, and measured the absorption line shapes of the CO2 line using 20 wavelength samples per scan. Measurements were made at stepped altitudes from 3 to 12.6 km over the Lamont OK, central Illinois, North Carolina, and over the Virginia Eastern Shore. Although the received signal energies were weaker than expected for ASCENDS, clear C02 line shapes were observed at all altitudes. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We averaged every 10 seconds of measurements and used a cross-correlation approach to estimate the range to the scattering surface and the echo pulse energy at each wavelength. We then solved for the best-fit CO2 absorption line shape, and calculated the DOD of the fitted CO2 line, and computed its statistics at the various altitude steps. We compared them to CO2 optical depths calculated from spectroscopy based on HITRAN 2008 and the column number densities calculated from the airborne in-situ readings. The 2009 measurements have been analyzed in detail and they were similar on all flights. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. They showed the expected nearly the linear dependence of DOD vs

  16. Experimental validation of pulsed column inventory estimators

    International Nuclear Information System (INIS)

    Beyerlein, A.L.; Geldard, J.F.; Weh, R.; Eiben, K.; Dander, T.; Hakkila, E.A.

    1991-01-01

    Near-real-time accounting (NRTA) for reprocessing plants relies on the timely measurement of all transfers through the process area and all inventory in the process. It is difficult to measure the inventory of the solvent contractors; therefore, estimation techniques are considered. We have used experimental data obtained at the TEKO facility in Karlsruhe and have applied computer codes developed at Clemson University to analyze this data. For uranium extraction, the computer predictions agree to within 15% of the measured inventories. We believe this study is significant in demonstrating that using theoretical models with a minimum amount of process data may be an acceptable approach to column inventory estimation for NRTA. 15 refs., 7 figs

  17. Propagation and diffusion of a plasma column in a magnetic field

    International Nuclear Information System (INIS)

    Bottiglioni, F.; Coutant, J.; Gadda, E.; Prevot, F.

    1966-12-01

    A plasma column is created in a magnetic field by longitudinal diffusion from a low-pressure pulsed discharge in hydrogen. Depending on the discharge conditions, two regimes are obtained in which the gas pumping speed has a different effect upon the plasma density in the column. Calculations are presented which can explain this effect by a difference in the transverse diffusion coefficient. (authors) [fr

  18. Pulsed electric field processing for fruit and vegetables

    Science.gov (United States)

    This month’s column reviews the theory and current applications of pulsed electric field (PEF) processing for fruits and vegetables to improve their safety and quality. This month’s column coauthor, Stefan Toepfl, is advanced research manager at the German Institute of Food Technologies and professo...

  19. Increasing flexibility in two-dimensional liquid chromatography by pulsed elution of the first dimension

    DEFF Research Database (Denmark)

    Jakobsen, Simon S.; Christensen, Jan H.; Verdier, Sylvain

    2017-01-01

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension...... online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity...

  20. Comparison of twin-cell centrifugal partition chromatographic columns with different cell volume.

    Science.gov (United States)

    Goll, Johannes; Audo, Gregoire; Minceva, Mirjana

    2015-08-07

    Two twin-cell centrifugal partition chromatographic columns (SCPC 250 and SCPE-250-BIO, Armen Instrument, France) with the same column volume but different cell size and number were compared in terms of stationary phase retention and column efficiency. The columns were tested with two types of solvent systems: a commonly used organic solvent based biphasic system from the ARIZONA solvent system family and a polymer/salt based aqueous two phase system (ATPS). The efficiency of the columns was evaluated by pulse injection experiments of two benzenediols (pyrocatechol and hydroquinone) in the case of the ARIZONA system and a protein mixture (myoglobin and lysozyme) in the case of the ATPS. As result of high stationary phase retention, the column with the lower number of larger twin-cells (SCPE-250-BIO) is suitable for protein separations using ATPS. On the other hand, due to higher column efficiency, the column with the greater number of smaller cells (SCPC 250) is superior for batch elution separations performed with standard liquid-liquid chromatography organic solvent based biphasic systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A new co conversion technology based on liquid/liquid extraction column

    Energy Technology Data Exchange (ETDEWEB)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Brackx, Emmanuelle [CEA Valrho - Marcoule - BP 17171 - 30207 Bagnols sur Ceze Cedex (France)

    2009-06-15

    The current objective of implementing 'direct' coprecipitation of uranium, plutonium and minor actinides for nuclear fuel re-fabrication leads to reconsider the (co)precipitation step, and more precisely its adaptability to new flowrates' specifications. Indeed, coprecipitation of a uranium fraction together with plutonium results in an appreciable increase in the process flow rates for this step. The technological impact of the increase in capacity could require the development of a different concept for a continuous device capable of ensuring the proposed process. A new type of device designed and patented by the CEA has been tested since 2007. The patent is for organic confinement in a pulsed column (PC) or Couette column (CC). The precipitation reaction between the oxalate complexing agent and a surrogate nitrate-cerium(II) or neodymium(III) alone, or coprecipitated uranium(IV) and cerium(III), occurs within an emulsion created in the device by these two phases flowing with a counter-current chemically inert organic phase (for example TPH) produced by the stirring action of the pulsator (PC) or the central rotor (CC). The precipitate is confined and thus does not form deposits on the vessel walls (which are also water-repellent); it flows downward by gravity and exits the column continuously into a settling tank. This paper describes the recent results obtained with this new technology for precipitation of Ce and Nd and coprecipitation of U + Ce in pulsed column and Couette column. It describes a first modeling allowing further extrapolation of this device to high capacities. (authors)

  2. Axial mixing for both dispersed and continuous phases in pulsed perforated-plate extraction column by tracer co-injection method

    International Nuclear Information System (INIS)

    Ikeda, Hidematsu; Suzuki, Atsuyuki.

    1991-01-01

    The effects of operation mode and perforated-plate type on axial mixing of mixer-settler region in both dispersed and continuous phases were studied for a 5 cm I.D. pulsed perforated-plate extraction column of pulser-feeder type. The axial mixing coefficient was simultaneously measured to both phases by using the 'dynamic tracer co-injection method' proposed by the authors. The characteristics of both phases are observed obviously. Relatively to what it was in the continuous phase, the dispersed phase had short reaching time and long retardation time. The superficial axial mixing coefficient for dispersed phase becomes smaller than for the continuous phase. And experimental results showed that a backflow took place only in dispersed phase at a test section of 50 cm in axial length. The values of backflow ratio are observed from 0.5 to 1.8% of the dispersed net flow. (author)

  3. Column carbon dioxide and water vapor measurements by an airborne triple-pulse integrated path differential absorption lidar: novel lidar technologies and techniques with path to space

    Science.gov (United States)

    Singh, U. N.; Petros, M.; Refaat, T. F.; Yu, J.; Ismail, S.

    2017-09-01

    The 2-micron wavelength region is suitable for atmospheric carbon dioxide (CO2) measurements due to the existence of distinct absorption features for the gas at this wavelength region [1]. For more than 20 years, researchers at NASA Langley Research Center (LaRC) have developed several high-energy and high repetition rate 2-micron pulsed lasers [2]. Currently, LaRC team is engaged in designing, developing and demonstrating a triple-pulsed 2-micron direct detection Integrated Path Differential Absorption (IPDA) lidar to measure the weighted-average column dry-air mixing ratios of carbon dioxide (XCO2) and water vapor (XH2O) from an airborne platform [1, 3-5]. This novel technique allows measurement of the two most dominant greenhouse gases, simultaneously and independently, using a single instrument. This paper will provide status and details of the development of this airborne 2-micron triple-pulse IPDA lidar. The presented work will focus on the advancement of critical IPDA lidar components. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of seed laser locking, wavelength control, receiver and detector upgrades, laser packaging and lidar integration. Future plans for IPDA lidar ground integration, testing and flight validation will also be discussed. This work enables new Earth observation measurements, while reducing risk, cost, size, volume, mass and development time of required instruments.

  4. Behaviour analysis of uranium purification pilot plant taking into consideration the incorporation of a second column of extraction in the process flow chart

    International Nuclear Information System (INIS)

    Souza Barbosa, E.M. de.

    1979-01-01

    This work analyses the effect of the incorporation of a second column of extraction by solvents in pulsed plate columns in the Process of Uranium Purification. Operating with the aqueous phase of washing this second column of extraction recovers the dragged Uranium, increasing the efficiency of the process. The experiments were carried out in the display unit of Uranium purification in the Institute of Energetic and Nuclear Researches in Sao Paulo, where the dimension and the performance were studied with the following parameters: real increase in the efficiency and decontamination in the process. An efficiency superior to 98% in mass was obtained against 84,6% in the conventional process. With a performance similar to the first column of extract on the decontamination, about 99%, obtained in this column, maintained the grade of nuclear purity peculiar to the Process of Uranium Purification by solvents in pulsed plate columns. (author) [pt

  5. A new oxalate co-conversion technology based on liquid/liquid extraction columns

    International Nuclear Information System (INIS)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Allegri, Patrick

    2008-01-01

    The current objective of fabricating non proliferating nuclear fuel by 'direct' coprecipitation of uranium, plutonium and minor actinides requires a new process to replace the (co)precipitation step. The technological impact of an increased capacity on the work zone could require the development of a different concept for a continuous device capable of ensuring the proposed goal. A new type of device designed and patented by the Cea was tested in 2007. The patent is for organic confinement in a pulsed column. First, precipitation of cerium or neodymium alone has been carried out in this device, with satisfactory results. Moreover, a recent test campaign demonstrated that a uranium-cerium co-precipitate easily forms when the two nitrates are mixed in a pulsed column of the same size operating under very similar process conditions. Qualitatively, the co-precipitate meets the process requirements. (authors)

  6. Water column velocimeter for NSRR experiment. Characteristics and data processing procedure

    International Nuclear Information System (INIS)

    Sugiyama, Tomoyuki; Fuketa, Toyoshi

    2000-11-01

    In order to clarify fuel behavior under reactivity initiated accident (RIA) conditions, pulse irradiation experiments on fuel rods are carried out in the Nuclear Safety Research Reactor (NSRR). One of concerns at fuel failure is mechanical energy generation in the reactor vessel. The mechanical energy is generated by a water hammer or a pressure impact occurred at fuel failure, and has possibility to damage reactor structures. Thus, the amount of generated mechanical energy is critical information for the safety evaluation of power reactor. In the NSRR experiments, the mechanical energy due to the water hammer is evaluated as the kinetic energy of the jumping water column at fuel failure, and the velocity of the water column is measured by the float type water column velocimeter. This report presents characteristics of the water column velocimeter and the procedure of data processing in the NSRR experiments. (author)

  7. Exhaust properties of centre-column-limited plasmas on MAST

    International Nuclear Information System (INIS)

    Maddison, G.P.; Akers, R.J.; Brickley, C.; Gryaznevich, M.P.; Lott, F.C.; Patel, A.; Sykes, A.; Turner, A.; Valovic, M.

    2007-01-01

    The lowest aspect ratio possible in a spherical tokamak is defined by limiting the plasma on its centre column, which might therefore maximize many physics benefits of this fusion approach. A key issue for such discharges is whether loads exhausted onto the small surface area of the column remain acceptable. A first series of centre-column-limited pulses has been examined on MAST using fast infra-red thermography to infer incident power densities as neutral-beam heating was scanned from 0 to 2.5 MW. Simple mapping shows that efflux distributions on the column armour are governed mostly by magnetic geometry, which moreover spreads them advantageously over almost the whole vertical length. Hence steady peak power densities between sawteeth remained low, -2 , comparable with the target strike-point value in a reference diverted plasma at lower power. Plasma purity and normalized thermal energy confinement through the centre-column-limited (CCL) series were also similar to properties of MAST diverted cases. A major bonus of CCL geometry is a propensity for exhaust to penetrate through its inner scrape-off layer connecting to the column into an expanding outer plume, which forms a 'natural divertor'. Effectiveness of this process may even increase with plasma heating, owing to rising Shafranov shift and/or toroidal rotation. A larger CCL device could potentially offer a simpler, more economic next-step design

  8. A new oxalate co-conversion technology based on liquid/liquid extraction columns

    Energy Technology Data Exchange (ETDEWEB)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Allegri, Patrick [CEA Nuclear Energy Division - Fuel Cycle Technology Division - System and Chemical Engineering Device Marcoule - 30207 Bagnols sur Ceze (France)

    2008-07-01

    The current objective of fabricating non proliferating nuclear fuel by 'direct' coprecipitation of uranium, plutonium and minor actinides requires a new process to replace the (co)precipitation step. The technological impact of an increased capacity on the work zone could require the development of a different concept for a continuous device capable of ensuring the proposed goal. A new type of device designed and patented by the Cea was tested in 2007. The patent is for organic confinement in a pulsed column. First, precipitation of cerium or neodymium alone has been carried out in this device, with satisfactory results. Moreover, a recent test campaign demonstrated that a uranium-cerium co-precipitate easily forms when the two nitrates are mixed in a pulsed column of the same size operating under very similar process conditions. Qualitatively, the co-precipitate meets the process requirements. (authors)

  9. Axial dispersion, holdup and slip velocity of dispersed phase in a pulsed sieve plate extraction column by radiotracer residence time distribution analysis.

    Science.gov (United States)

    Din, Ghiyas Ud; Chughtai, Imran Rafiq; Inayat, Mansoor Hameed; Khan, Iqbal Hussain

    2008-12-01

    Axial dispersion, holdup and slip velocity of dispersed phase have been investigated for a range of dispersed and continuous phase superficial velocities in a pulsed sieve plate extraction column using radiotracer residence time distribution (RTD) analysis. Axial dispersion model (ADM) was used to simulate the hydrodynamics of the system. It has been observed that increase in dispersed phase superficial velocity results in a decrease in its axial dispersion and increase in its slip velocity while its holdup increases till a maximum asymptotic value is achieved. An increase in superficial velocity of continuous phase increases the axial dispersion and holdup of dispersed phase until a maximum value is obtained, while slip velocity of dispersed phase is found to decrease in the beginning and then it increases with increase in superficial velocity of continuous phase.

  10. Simulation of multi-pulse coaxial helicity injection in the Sustained Spheromak Physics Experiment

    Science.gov (United States)

    O'Bryan, J. B.; Romero-Talamás, C. A.; Woodruff, S.

    2018-03-01

    Nonlinear, numerical computation with the NIMROD code is used to explore magnetic self-organization during multi-pulse coaxial helicity injection in the Sustained Spheromak Physics eXperiment. We describe multiple distinct phases of spheromak evolution, starting from vacuum magnetic fields and the formation of the initial magnetic flux bubble through multiple refluxing pulses and the eventual onset of the column mode instability. Experimental and computational magnetic diagnostics agree on the onset of the column mode instability, which first occurs during the second refluxing pulse of the simulated discharge. Our computations also reproduce the injector voltage traces, despite only specifying the injector current and not explicitly modeling the external capacitor bank circuit. The computations demonstrate that global magnetic evolution is fairly robust to different transport models and, therefore, that a single fluid-temperature model is sufficient for a broader, qualitative assessment of spheromak performance. Although discharges with similar traces of normalized injector current produce similar global spheromak evolution, details of the current distribution during the column mode instability impact the relative degree of poloidal flux amplification and magnetic helicity content.

  11. Rotation of a magnesium plasma column in a background gas

    International Nuclear Information System (INIS)

    Bosco, E. Del; Dallaqua, R.S.

    1993-01-01

    Measurements of the angular velocity of a plasma column in a surrounding gas atmosphere are presented. The plasma is produced by a pulsed, high current arc discharge in the presence of an axial magnetic field. The angular velocity is measured using the cross correlation technique applied to the floating potential signals measured by two Langmuir probes. The main result is that when gas is added to the discharge the angular velocity is always lower than the case when there is no gas, this effect been more pronounced in the beginning of the discharge. For pressures higher than ∼ 2 x 10 -2 Pa there is a effect of the gas on the plasma column rotation and the angular velocity diminishes even at the end of discharge. (author)

  12. Comparison of SX of uranium using mixer settler and columns

    International Nuclear Information System (INIS)

    Grinbaum, B.; Kotze, M.; Buchalter, E.

    2010-01-01

    Two types of equipment are used in the industry for solvent extraction (SX) of U: mixer-settlers (MS) and columns. Currently the only published type of columns applied in U SX is the Bateman Pulsed Columns (BPC). These columns have been applied for extraction of U for more than 13 years in Olympic Dam plant in Australia and in recent years were also introduced to additional plants in Australia and South Africa. Other plants are using MS of various types. The columns are currently used in the extraction battery only. For stripping and scrubbing only MS are currently used. Although pilot tests prove that the pH gradient required in the stripping may be successfully obtained in the BPC, they have not yet been applied in the industry. The paper compares the extraction and stripping in both types of equipment, regarding the capital cost, operating costs and operating conditions. The capital cost of the BPC is lower by 33-40%, depending on the size of the plant and the quality of the ore. The operating costs with the BPC are slightly lower, due to smaller losses of solvent. From operating point of view the BPC has the ability to recover from phase inversion and precipitation of yellow cake without the need to shut down the plant, if the problem is addressed within a few minutes. (author)

  13. Reprocessing of spent nuclear fuel, Annex 1: Experimental facility for testing and development of pulsed columns and auxiliary devices; Prerada isluzenog nuklearnog goriva, Prilog 1: Opitno postrojenje za ispitivanje i razvoj pulsnih kolona i pomocnih uredjaja

    Energy Technology Data Exchange (ETDEWEB)

    Gal, I [Institute of Nuclear Sciences Boris Kidric, Laboratorija za hemiju visoke aktivnosti, Vinca, Beograd (Serbia and Montenegro)

    1964-12-15

    After completing the design project for building the experimental facility for testing and development of pulsed columns for spent fuel reprocessing, the construction started by the end of 1963 and was completed in August 1964. The facility was built in Kjeller, Norway within cooperation project between out country and Norway. This report covers a brief description of the facility and the action plan of its implementation.

  14. Effect of oxygen on ethanol fermentation in packed-bed tapered-column reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hamamci, H.; Ryu, D.D.Y.

    1988-07-01

    In ethanol production with immobilized yeast a major problem is the provision of nutrients to these highly concentrated cells. O/sub 2/ being one of the nutrients of utmost importance to yeast cells, was fed into a column packed with beads with a cell loading of more than 40 g/l. Since addition of large volume of air or O/sub 2/ to a cylindrical column reactor would aggravate the problems of pressure build up and channelling caused by the evolving CO/sub 2/ gas, a tapered-column reactor and pulsed flow of oxygen gas was used. The supplement of O/sub 2/ gas to the tapered column increased the productivity from 21.1 g ethanol x (l gel x h)/sup -1/ to 26.7 g x (l gelxh)/sup -1/, when the ethanol concentration at the outlet was about 80 g/l. The yield coefficient of ethanol was also increased from 0.41 g ethanol/g glucose to 0.43 after O/sub 2/ supplement was started. The effects of frequency and duration of O/sub 2/ supplement were also determined.

  15. Separation and determination of alditols and sugars by high-pH anion-exchange chromatography with pulsed amperometric detection

    DEFF Research Database (Denmark)

    Andersen, Rikke; Sørensen, A.

    2000-01-01

    Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic-pulsed a......Carbohydrates such as alditols (polyols or sugar alcohols), monosaccharides and disaccharides are separated as anions by anion-exchange chromatography with a sodium hydroxide eluent, MA1 CarboPac column and pulsed amperometric detection. We report a high-pH anion-exchange chromatographic......-pulsed amperometric detection (HPAEC-PAD) method that determines all the polyols used as food additives in food products and the most commonly found mono- and disaccharides on a routine basis. The linearity, repeatability, internal reproducibility and accuracy are described. The applicability of the method has been...

  16. Modeling Stone Columns.

    Science.gov (United States)

    Castro, Jorge

    2017-07-11

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  17. Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns?

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Dennis, Gary R; Shalliker, R Andrew

    2015-08-19

    Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 μm particles. The data showed that reaction loops beyond 100 μL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column. Copyright © 2015. Published by Elsevier B.V.

  18. Pulsed field magnetization strategies and the field poles composition in a bulk-type superconducting motor

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhen, E-mail: zhen.huang@sjtu.edu.cn [Academy of Information Technology and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240 (China); Ruiz, H.S., E-mail: dr.harold.ruiz@le.ac.uk [Department of Engineering, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Coombs, T.A., E-mail: tac1000@cam.ac.uk [Department of Engineering, University of Cambridge, 9 JJ Thomson Avenue, Cambridge CB3 0FA (United Kingdom)

    2017-03-15

    Highlights: • Different compositions of the magnetic poles have been obtained depending on the relative orientation of the magnetizing coil and the surfaces of the columns of bulks that conform a magnetic pole. • Two bidimensional models accounting for the electromagnetic response of the top and lateral cross sections of three columns of HTS bulks subjected to multiple pulsed magnetic fields have been created. • An extended PFM strategy has been proposed by considering the magnetization of at least three successive columns of HTS bulks per pole. In the extended PFM strategy the area of each one of the poles can be seen increased by a factor of 200%-400% - Abstract: High temperature superconducting (HTS) bulks offer the potential of trapping and maintaining much higher magnetic loading level compared with the conventional permanent magnets used in rotary machines, although the effective magnetization of multiple HTS bulks with different relative orientations over the surface of cylindrical rotors creates new challenges. In this paper, we present the design and numerical validation of the Pulse Field Magnetization (PFM) strategy considered for the magnetization of the four-pole synchronous fully superconducting motor developed at the University of Cambridge. In a first instance, singular columns of up to five HTS bulks aligned over the height of the rotor were subjected to up to three magnetic pulses of 1.5 T peak, and the experimental results have been simulated by considering the electrical and thermal properties of the system in a 2D approach. The entire active surface of the rotor is covered by HTS bulks of approximately the same dimensions, resulting in an uneven distribution of pole areas with at least one of the poles formed by up to 3 columns of magnetized bulks, with relatively the same peaks of trapped magnetic field. Thus, in order to effectively use the entire area of the superconducting rotor, multiple pulsed fields per column have been applied

  19. Pulsed field magnetization strategies and the field poles composition in a bulk-type superconducting motor

    International Nuclear Information System (INIS)

    Huang, Zhen; Ruiz, H.S.; Coombs, T.A.

    2017-01-01

    Highlights: • Different compositions of the magnetic poles have been obtained depending on the relative orientation of the magnetizing coil and the surfaces of the columns of bulks that conform a magnetic pole. • Two bidimensional models accounting for the electromagnetic response of the top and lateral cross sections of three columns of HTS bulks subjected to multiple pulsed magnetic fields have been created. • An extended PFM strategy has been proposed by considering the magnetization of at least three successive columns of HTS bulks per pole. In the extended PFM strategy the area of each one of the poles can be seen increased by a factor of 200%-400% - Abstract: High temperature superconducting (HTS) bulks offer the potential of trapping and maintaining much higher magnetic loading level compared with the conventional permanent magnets used in rotary machines, although the effective magnetization of multiple HTS bulks with different relative orientations over the surface of cylindrical rotors creates new challenges. In this paper, we present the design and numerical validation of the Pulse Field Magnetization (PFM) strategy considered for the magnetization of the four-pole synchronous fully superconducting motor developed at the University of Cambridge. In a first instance, singular columns of up to five HTS bulks aligned over the height of the rotor were subjected to up to three magnetic pulses of 1.5 T peak, and the experimental results have been simulated by considering the electrical and thermal properties of the system in a 2D approach. The entire active surface of the rotor is covered by HTS bulks of approximately the same dimensions, resulting in an uneven distribution of pole areas with at least one of the poles formed by up to 3 columns of magnetized bulks, with relatively the same peaks of trapped magnetic field. Thus, in order to effectively use the entire area of the superconducting rotor, multiple pulsed fields per column have been applied

  20. Assembly for connecting the column ends of two capillary columns

    International Nuclear Information System (INIS)

    Kolb, B.; Auer, M.; Pospisil, P.

    1984-01-01

    In gas chromatography, the column ends of two capillary columns are inserted into a straight capillary from both sides forming annular gaps. The capillary is located in a tee out of which the capillary columns are sealingly guided, and to which carrier gas is supplied by means of a flushing flow conduit. A ''straight-forward operation'' having capillary columns connected in series and a ''flush-back operation'' are possible. The dead volume between the capillary columns can be kept small

  1. The application of PLC automatic control system for resin transfer in pulsed elution

    International Nuclear Information System (INIS)

    Long Maoxiong

    2001-01-01

    An application of Programmable Logic Controller (PLC) in automatic control system for resin transfer in pulsed elution column is described. The design principle as well as hardware and software are also described in detail

  2. Contributions to reversed-phase column selectivity: III. Column hydrogen-bond basicity.

    Science.gov (United States)

    Carr, P W; Dolan, J W; Dorsey, J G; Snyder, L R; Kirkland, J J

    2015-05-22

    Column selectivity in reversed-phase chromatography (RPC) can be described in terms of the hydrophobic-subtraction model, which recognizes five solute-column interactions that together determine solute retention and column selectivity: hydrophobic, steric, hydrogen bonding of an acceptor solute (i.e., a hydrogen-bond base) by a stationary-phase donor group (i.e., a silanol), hydrogen bonding of a donor solute (e.g., a carboxylic acid) by a stationary-phase acceptor group, and ionic. Of these five interactions, hydrogen bonding between donor solutes (acids) and stationary-phase acceptor groups is the least well understood; the present study aims at resolving this uncertainty, so far as possible. Previous work suggests that there are three distinct stationary-phase sites for hydrogen-bond interaction with carboxylic acids, which we will refer to as column basicity I, II, and III. All RPC columns exhibit a selective retention of carboxylic acids (column basicity I) in varying degree. This now appears to involve an interaction of the solute with a pair of vicinal silanols in the stationary phase. For some type-A columns, an additional basic site (column basicity II) is similar to that for column basicity I in primarily affecting the retention of carboxylic acids. The latter site appears to be associated with metal contamination of the silica. Finally, for embedded-polar-group (EPG) columns, the polar group can serve as a proton acceptor (column basicity III) for acids, phenols, and other donor solutes. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  4. Beam pulsing of C60 electrostatic injector accelerator for linac

    International Nuclear Information System (INIS)

    Takahashi, Y.; Hattori, T.; Kashiwagi, H.; Hata, T.; Noda, K.

    2000-01-01

    The research which measured the energy loss by the interaction between C 60 fullerene beam and solid film using the TOF method was started. The beam pulsing equipment was manufactured in this reason. The method by the copping was adopted for the pulsing, and 10 kHz high frequency was applied between electrodes, and the 20 V maximum voltage between electrodes was obtained. The 600 keV acceleration will be carried out by the 200 kV accelerating column, after pulsing is sent to C 60 fullerene beam drawn from electron impact type ion source at 300 V in pulse intervals 50 μs and 4.6 μs pulse width. The APF-IH type linear accelerator that it settles the fullerene more and more using the APF focusing and accelerates at the high acceleration is designed and is manufactured, and this is made to be a linear accelerator of back step, the high energy acceleration will be carried out. (author)

  5. Column Liquid Chromatography.

    Science.gov (United States)

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  6. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M., E-mail: anacamiqui@gmail.com, E-mail: egoncalves@con.ufrj.br, E-mail: brandao@ien.gov.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  7. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    International Nuclear Information System (INIS)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M.

    2017-01-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  8. Study of efficacy in a mercury-free flat discharge fluorescent lamp using a zero-dimensional positive column model

    CERN Document Server

    Shiga, T; Boeuf, J P; Mikoshiba, S

    2003-01-01

    A zero-dimensional model of the positive column in Ar/Ne/Xe gas mixtures has been developed to help understand the measured dependence of the efficacy on operating conditions in a mercury-free flat fluorescent lamp in a dielectric barrier geometry. The experimental conditions are such that the radiation from the discharge is homogeneous over most of the discharge voltage. The model uses as input the discharge current waveform from the experiments, and it yields the time variations of the mean electron energy and the species densities. From these quantities we calculate the number of vacuum ultraviolet (VUV) photons emitted by the xenon resonance atoms and excimers during one current pulse and the efficiency for generation of VUV radiation in the positive column, which are compared with the measured luminance and efficacy for various voltages, pulse intervals, and lamp sizes. Over the range of conditions studied, we find that most electrical energy dissipated in xenon excitation is converted to VUV radiation; ...

  9. Numerical modelling and experimental validation of hydrodynamics of an emulsion in an extraction column

    International Nuclear Information System (INIS)

    Paisant, Jean-Francois

    2014-01-01

    Industrial reprocessing of spent fuel is based on chemical separation processes by liquid-liquid extraction into pulsed column. The current context of sustainable development and acceptance of nuclear energy drive the industry to improve the efficiency of this process. Pulsed column efficiency is bound to the amount of available exchange surface, which depends on the geometrical parameters of the column and the operating conditions. A better design would improve the efficiency. In this context, the work presented in this manuscript revolves around physical and numerical modelling of the hydrodynamics of the emulsion coupled with the evolution of the interfacial area, as well as an experimental characterization of the quantities which describe the emulsion. The emulsion is modelled based on the work of D. LHUILLIER. It is an Eulerian approach which describes each phase as a continuous medium as well as the interface which is thought as a third phase moving continuously in the flow field. This thesis contributes to describe of the hydrodynamics of dispersed and continuous phases, in order to determine the slip velocity needed for the design. The written transport equation for interfacial area is based on the thesis of T. RANDRIAMANANTENA. The simulation of this physical model was performed using the method of finite elements (FEM) and implementation was carried out under the software CAST3M. The numerical simulation have shown their abilities to correctly reproduce the expected physical behaviour, in particular, they allow to obtain the slip velocity which is essential to the scale up. In a first experimental approach, the single phase flow has been studied in a pulsed column using particle image velocimetry (PIV), for different amplitude and frequency parameters. A method of synchronization between the recording and the pulsation cycle was used in order to achieve this study. The average behavior, for different regimes of pulsation, has been studied by this way. In

  10. MR imaging studies of multiple myeloma in the vertebral column

    International Nuclear Information System (INIS)

    Albert, S.; Leeds, N.E.

    1990-01-01

    This paper studies the sensitivity and characteristics of MR imaging in the diagnosis of myeloma in the vertebral column. The cervical, thoracic, and lumbar spines of 12 patients with known multiple myeloma were imaged with small flip angle, fast gradient-echo, proton-density (FPD) as well as spin-echo T1-weighted, T2-weighted, and intermediate (SE 2,000/20-30) imaging. The FPD images were acquired with pulse sequence gradient recalled acquisition in a steady state at a magnetic field strength of 1.5T with use of a license-plate and a circular surface coil

  11. Column-Oriented Database Systems (Tutorial)

    NARCIS (Netherlands)

    D. Abadi; P.A. Boncz (Peter); S. Harizopoulos

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as

  12. Exponential frequency spectrum and Lorentzian pulses in magnetized plasmas

    International Nuclear Information System (INIS)

    Pace, D. C.; Shi, M.; Maggs, J. E.; Morales, G. J.; Carter, T. A.

    2008-01-01

    Two different experiments involving pressure gradients across the confinement magnetic field in a large plasma column are found to exhibit a broadband turbulence that displays an exponential frequency spectrum for frequencies below the ion cyclotron frequency. The exponential feature has been traced to the presence of solitary pulses having a Lorentzian temporal signature. These pulses arise from nonlinear interactions of drift-Alfven waves driven by the pressure gradients. In both experiments the width of the pulses is narrowly distributed resulting in exponential spectra with a single characteristic time scale. The temporal width of the pulses is measured to be a fraction of a period of the drift-Alfven waves. The experiments are performed in the Large Plasma Device (LAPD-U) [W. Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)] operated by the Basic Plasma Science Facility at the University of California, Los Angeles. One experiment involves a controlled, pure electron temperature gradient associated with a microscopic (6 mm gradient length) hot electron temperature filament created by the injection a small electron beam embedded in the center of a large, cold magnetized plasma. The other experiment is a macroscopic (3.5 cm gradient length) limiter-edge experiment in which a density gradient is established by inserting a metallic plate at the edge of the nominal plasma column of the LAPD-U. The temperature filament experiment permits a detailed study of the transition from coherent to turbulent behavior and the concomitant change from classical to anomalous transport. In the limiter experiment the turbulence sampled is always fully developed. The similarity of the results in the two experiments strongly suggests a universal feature of pressure-gradient driven turbulence in magnetized plasmas that results in nondiffusive cross-field transport. This may explain previous observations in helical confinement devices, research tokamaks, and arc plasmas.

  13. Family of columns isospectral to gravity-loaded columns with tip force: A discrete approach

    Science.gov (United States)

    Ramachandran, Nirmal; Ganguli, Ranjan

    2018-06-01

    A discrete model is introduced to analyze transverse vibration of straight, clamped-free (CF) columns of variable cross-sectional geometry under the influence of gravity and a constant axial force at the tip. The discrete model is used to determine critical combinations of loading parameters - a gravity parameter and a tip force parameter - that cause onset of dynamic instability in the CF column. A methodology, based on matrix-factorization, is described to transform the discrete model into a family of models corresponding to weightless and unloaded clamped-free (WUCF) columns, each with a transverse vibration spectrum isospectral to the original model. Characteristics of models in this isospectral family are dependent on three transformation parameters. A procedure is discussed to convert the isospectral discrete model description into geometric description of realistic columns i.e. from the discrete model, we construct isospectral WUCF columns with rectangular cross-sections varying in width and depth. As part of numerical studies to demonstrate efficacy of techniques presented, frequency parameters of a uniform column and three types of tapered CF columns under different combinations of loading parameters are obtained from the discrete model. Critical combinations of these parameters for a typical tapered column are derived. These results match with published results. Example CF columns, under arbitrarily-chosen combinations of loading parameters are considered and for each combination, isospectral WUCF columns are constructed. Role of transformation parameters in determining characteristics of isospectral columns is discussed and optimum values are deduced. Natural frequencies of these WUCF columns computed using Finite Element Method (FEM) match well with those of the given gravity-loaded CF column with tip force, hence confirming isospectrality.

  14. Distillation Column Flooding Predictor

    Energy Technology Data Exchange (ETDEWEB)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  15. Column-Oriented Database Systems (Tutorial)

    OpenAIRE

    Abadi, D.; Boncz, Peter; Harizopoulos, S.

    2009-01-01

    textabstractColumn-oriented database systems (column-stores) have attracted a lot of attention in the past few years. Column-stores, in a nutshell, store each database table column separately, with attribute values belonging to the same column stored contiguously, compressed, and densely packed, as opposed to traditional database systems that store entire records (rows) one after the other. Reading a subset of a table’s columns becomes faster, at the potential expense of excessive disk-head s...

  16. An investigation of pulsed high density plasmas

    International Nuclear Information System (INIS)

    Timmermans, C.J.

    1984-01-01

    In this thesis a wall-stabilized argon cascade arc is studied at values of pulsed pressure up to 14 bar and a pulsed current range up to 2200 A with a time duration of about 2 ms. The basic plasma is a CW cascade arc with a 5 mm diameter plasma column and a length of 90 mm, which operates at a 60 A DC current and at one atmosphere filling pressure. The author starts with an extensive summary of the CW arc investigations. After a brief introduction of the basic transport equations the mass equations of the constituent particles are treated using the extended collisional radiative model. The energy balance equations and the momentum balance are discussed. The electron density is determined from measurements of the continuum radiation. The final chapter contains the experimental results on the electron temperatures and electron densities in the pressure and current pulsed plasma. Attention is given to the deviations from local thermodynamic equilibrium values of the ground level densities of the different argon systems. (Auth.)

  17. Nuclear reactor control column

    International Nuclear Information System (INIS)

    Bachovchin, D.M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest crosssectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor

  18. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    Science.gov (United States)

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  19. Improvements in solvent extraction columns

    International Nuclear Information System (INIS)

    Aughwane, K.R.

    1987-01-01

    Solvent extraction columns are used in the reprocessing of irradiated nuclear fuel. For an effective reprocessing operation a solvent extraction column is required which is capable of distributing the feed over most of the column. The patent describes improvements in solvent extractions columns which allows the feed to be distributed over an increased length of column than was previously possible. (U.K.)

  20. Probe development of CMUT and PZT row-column-addressed 2-D arrays

    DEFF Research Database (Denmark)

    Engholm, Mathias; Bouzari, Hamed; Christiansen, Thomas Lehrmann

    2018-01-01

    for driving the 128-channel coaxial cable to the scanner. The electronics were designed to allow all elements, both rows and columns, to be used interchangeably as either transmitters or receivers. The transducer characterization i.e. bandwidth, phase delay, surface pressure, sensitivity, insertion loss......, and acoustical crosstalk, were based on several single element measurements, including pressure and pulse-echo, and were evaluated quantitatively and comparatively. The weighted center frequency was 3.0 MHz for both probes and the measured -6 dB fractional bandwidth was 109 ± 4% and 80 ± 3% for the CMUT...

  1. ( Anogeissus leiocarpus ) timber columns

    African Journals Online (AJOL)

    A procedure for designing axially loaded Ayin (Anogeissus leiocarpus) wood column or strut has been investigated. Instead of the usual categorization of columns into short, intermediate and slender according to the value of slenderness ratio, a continuous column formula representing the three categories was derived.

  2. Early Stages of Pulsed-Laser Growth of Silicon Microcolumns and Microcones in Air and SF6

    International Nuclear Information System (INIS)

    Fowlkes, J.D.; Lowndes, D.H.; Pedraza, A.J.

    1999-01-01

    Dense arrays of high-aspect-ratio silicon microcolumns and microcones are formed by cumulative nanosecond pulsed excimer laser irradiation of single-crystal silicon in oxidizing atmospheres such as air and SF 6 . Growth of such surface microstructures requires a redeposition model and also involves elements of self-organization. The shape of the microstructures, i.e. straight columns vs steeply sloping cones and connecting walls, is governed by the type and concentration of the oxidizing species, e.g. oxygen vs fluorine. Growth is believed to occur by a catalyst-free VLS (vapor-liquid-solid) mechanism that involves repetitive melting of the tips of the columns/cones and deposition there of the ablated flux of Si-containing vapor. Results are presented of a new investigation of how such different final microstructures as microcolumns or microcones joined by walls nucleate and develop. The changes in silicon surface morphology were systematically determined and compared as the number of pulsed KrF (248 nm) laser shots was increased from 25 to several thousand in both air and SF 6 . The experiments in air and SF 6 reveal significant differences in initial surface cracking and pattern formation. Consequently, local protrusions are first produced and column or cone/wall growth is initiated by different processes and at different rates. Differences in the spatial organization of column or cone/wall growth also are apparent

  3. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  4. COLUMN2 - A computer program for simulating migration

    International Nuclear Information System (INIS)

    Nielsen, O.J.; Bo, P.; Carlsen, L.

    1985-10-01

    COLUMN2 is a 1D FORTRAN77 computer program designed for studies of the effects of various physicochemical processes on migration. It solves the solute transport equation and cant take into account dispersion, sorption, ion exchange, first and second order homogeneous chemical reactions. Spacial variations of input pulses and retention factors are possible. The method of solution is based on a finite difference discretion followed by the application of the method of characteristics and two separate grid systems. This report explains the mathematical and numerical methods used, describes the necessary input, contains a number of test examples, provides a listing of the program and explains how to acquire the program, adapt it to other computers and run it. This report serves as a manual for the program. (author)

  5. Histological examination of the oral mucosa after fractional diode laser irradiation with different power and pulse duration

    Science.gov (United States)

    Belikov, Andrey V.; Ermolaeva, Ludmila A.; Korzhevsky, Dmitriy E.; Sergeeva, Elena S.; Semyashkina, Yulia V.; Antropova, Maria M.; Fedotov, Denis Y.; Zaitseva, Maria A.; Kashina, Tatiana V.

    2018-04-01

    Optical and histological methods were used to examination of influence the power and pulse duration of 980-nm diode laser to the dimensions and morphology of tissue around fractional micro injuries created by the radiation of that laser in the oral mucosa of rats in vivo. The power of laser radiation (P) varied in the range of 1÷21 W, and its pulse duration (tp) - in the range 50÷500 ms. Histological examination showed that in the mucosa of the oral cavity after the laser fractional irradiation, there following effects are found: a tissue defect, a transudate in the lumen of ablative micro injury, stretching and compacting effect of the nuclei of the basal epithelium, the disappearance of granules of the keratohialin, destroying the structure of the connective tissue, erythrocyte stasis in the vessels, the disappearance of transverse striation in the muscle fibers in muscle layer. It has been found that ablative micro injury begins to form up at P = 5 W, tp = 100 ms and affects only the epithelial layer of the mucosa. At P = 7 W, tp = 120 ms, the ratio of width to depth of ablative micro injury is 1 : 1, and at P = 10 W, tp = 100 ms, an ablative micro column with ratio of 1 : 1.5 is formed in the epithelial and submucosal layers of the mucosa. The laser effect with P = 15 W, tp = 200 ms leads to lengthening of the ablation micro-column to 1 : 2, with the bottom of the ablative micro column reaching the muscular layer. With a further growth of laser power or pulse duration, the width of the micro injury increases, and the growth of the micro injury depth is slowed down so that the micro column buildup is ceased.

  6. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    Science.gov (United States)

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  7. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  8. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  9. Mass transfer model liquid phase catalytic exchange column simulation applicable to any column composition profile

    Energy Technology Data Exchange (ETDEWEB)

    Busigin, A. [NITEK USA Inc., Ocala, FL (United States)

    2015-03-15

    Liquid Phase Catalytic Exchange (LPCE) is a key technology used in water detritiation systems. Rigorous simulation of LPCE is complicated when a column may have both hydrogen and deuterium present in significant concentrations in different sections of the column. This paper presents a general mass transfer model for a homogenous packed bed LPCE column as a set of differential equations describing composition change, and equilibrium equations to define the mass transfer driving force within the column. The model is used to show the effect of deuterium buildup in the bottom of an LPCE column from non-negligible D atom fraction in the bottom feed gas to the column. These types of calculations are important in the design of CECE (Combined Electrolysis and Catalytic Exchange) water detritiation systems.

  10. Advances in High Energy Solid-State Pulsed 2-Micron Lidar Development for Ground and Airborne Wind, Water Vapor and CO2 Measurements

    Science.gov (United States)

    Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta; Refaat, Tamer; Kavaya, Michael J.; Remus, Ruben

    2015-01-01

    NASA Langley Research Center has a long history of developing 2-micron lasers. From fundamental spectroscopy research, theoretical prediction of new materials, laser demonstration and engineering of lidar systems, it has been a very successful program spanning around two decades. Successful development of 2-micron lasers has led to development of a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement with an unprecedented laser pulse energy of 250 millijoules in a rugged package. This high pulse energy is produced by a Ho:Tm:LuLiF laser with an optical amplifier. While the lidar is meant for use as an airborne instrument, ground-based tests were carried out to characterize performance of the lidar. Atmospheric measurements will be presented, showing the lidar's capability for wind measurement in the atmospheric boundary layer and free troposphere. Lidar wind measurements are compared to a balloon sonde, showing good agreement between the two sensors. Similar architecture has been used to develop a high energy, Ho:Tm:YLF double-pulsed 2-micron Integrated Differential Absorption Lidar (IPDA) instrument based on direct detection technique that provides atmospheric column CO2 measurements. This instrument has been successfully used to measure atmospheric CO2 column density initially from a ground mobile lidar trailer, and then it was integrated on B-200 plane and 20 hours of flight measurement were made from an altitude ranging 1500 meters to 8000 meters. These measurements were compared to in-situ measurements and National Oceanic and Atmospheric Administration (NOAA) airborne flask measurement to derive the dry mixing ratio of the column CO2 by reflecting the signal by various reflecting surfaces such as land, vegetation, ocean surface, snow and sand. The lidar measurements when compared showed a very agreement with in-situ and airborne flask measurement. NASA Langley Research Center is currently developing a

  11. Calculation of concentration profiles and their experimental verification with a pulsed sieve-plate column and the reactive material system of uranyl nitrate, nitric acid/tributyl phosphate, kerosine

    International Nuclear Information System (INIS)

    Ihle, E.

    1985-01-01

    The present study is concerned with the calculation of stationary and non-stationary concentration profiles as well as with the starting and disturbance behaviour of a pulsed sieve-plate extraction column. It investigates into the material system HNO 3 /uranyl nitrate in water with 30 per cent by volume of tributyl phosphate in kerosine. During the measurements of the concentration profiles for HNO 3 transition, which were effected in the direction of extraction and reextraction, it was shown that the concentration profiles measured in the mixer-settler range, in spite of a sixfold enlargement of the specific heat transfer area, do not differ essentially from those measured in the dispersion range. During the measurements of concentration profiles for HNO 3 /uranium transition, which were effected in the direction of coextraction and co-reextraction only for mixer-settler range, it was discovered that with increasing phase ratios, there is a depletion of the uranium concentration in the aqueous phase. If the phase ratio is further raised, it is the nitric acid, and not the uranium, that is depleted. (orig./PW) [de

  12. Electric field simulation and measurement of a pulse line ion accelerator

    International Nuclear Information System (INIS)

    Shen Xiaokang; Zhang Zimin; Cao Shuchun; Zhao Hongwei; Zhao Quantang; Liu Ming; Jing Yi; Wang Bo; Shen Xiaoli

    2012-01-01

    An oil dielectric helical pulse line to demonstrate the principles of a Pulse Line Ion Accelerator (PLIA) has been designed and fabricated. The simulation of the axial electric field of an accelerator with CST code has been completed and the simulation results show complete agreement with the theoretical calculations. To fully understand the real value of the electric field excited from the helical line in PLIA, an optical electric integrated electric field measurement system was adopted. The measurement result shows that the real magnitude of axial electric field is smaller than that calculated, probably due to the actual pitch of the resister column which is much less than that of helix. (authors)

  13. Two generalizations of column-convex polygons

    International Nuclear Information System (INIS)

    Feretic, Svjetlan; Guttmann, Anthony J

    2009-01-01

    Column-convex polygons were first counted by area several decades ago, and the result was found to be a simple, rational, generating function. In this work we generalize that result. Let a p-column polyomino be a polyomino whose columns can have 1, 2, ..., p connected components. Then column-convex polygons are equivalent to 1-convex polyominoes. The area generating function of even the simplest generalization, namely 2-column polyominoes, is unlikely to be solvable. We therefore define two classes of polyominoes which interpolate between column-convex polygons and 2-column polyominoes. We derive the area generating functions of those two classes, using extensions of existing algorithms. The growth constants of both classes are greater than the growth constant of column-convex polyominoes. Rather tight lower bounds on the growth constants complement a comprehensive asymptotic analysis.

  14. Development of spent salt treatment technology by zeolite column system. Performance evaluation of zeolite column

    International Nuclear Information System (INIS)

    Miura, Hidenori; Uozumi, Koichi

    2009-01-01

    At electrorefining process, fission products(FPs) accumulate in molten salt. To avoid influence on heating control by decay heat and enlargement of FP amount in the recovered fuel, FP elements must be removed from the spent salt of the electrorefining process. For the removal of the FPs from the spent salt, we are investigating the availability of zeolite column system. For obtaining the basic data of the column system, such as flow property and ion-exchange performance while high temperature molten salt is passing through the column, and experimental apparatus equipped with fraction collector was developed. By using this apparatus, following results were obtained. 1) We cleared up the flow parameter of column system with zeolite powder, such as flow rate control by argon pressure. 2) Zeolite 4A in the column can absorb cesium that is one of the FP elements in molten salt. From these results, we got perspective on availability of the zeolite column system. (author)

  15. Luminous flux improvement of xenon fluorescent lamps by applying synchronized high-voltage pulse to the auxiliary external electrode

    Energy Technology Data Exchange (ETDEWEB)

    Motomura, Hideki; Oka, Kojiro; Sogabe, Toru; Jinno, Masafumi, E-mail: hmoto@mayu.ee.ehime-u.ac.jp [Department of Electrical and Electronic Engineering, Ehime University 3 Bunkyo-cho, Matsuyama, Ehime 790-8577 (Japan)

    2011-06-08

    As the environmental awareness of people becomes stronger, the demand for mercury-free light sources also becomes stronger. The authors have been developing cold cathode fluorescent lamps in which xenon gas is filled as an ultraviolet radiator instead of mercury. Previously the authors reported the luminous flux enhancement method using a grounded auxiliary external electrode (AEE). In this paper, in order to improve the luminous flux much more, a positive voltage pulse which was synchronized to the main driving negative voltage pulse was applied to the AEE. As a result, the maximum input power increased under which the positive column did not constrict and the luminous flux improved by 70% at the xenon filling pressure of 6.7 kPa. It is proved that the positive voltage pulse application to the AEE with the amplitude of more than 2 kV expands the positive column in the radial direction. It is attributed to the phenomenon that the residual ions and electrons, which are generated by dielectric barrier discharge between the AEE and the anode during the falling edge of the negative pulse to the cathode, spread the discharge path from the anode towards the AEE during the cold cathode discharge mode. By increasing the xenon filling pressure, luminous efficacy was improved to 25 lm W{sup -1}.

  16. Development of air pulsed ejector mixer settlers of different capacities

    Energy Technology Data Exchange (ETDEWEB)

    Rajagopalan, C V; Periasamy, K; Koganti, S B [Reprocessing Programme, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1994-06-01

    Nuclear industry has made significant contributions in the development of liquid-liquid contactors, for the separation of one or more solutes from feed solutions wherein they provide a more economical alternative compared to other unit operations. The various equipment that are used can be broadly classified into three categories: (1) mixer settlers (2) liquid pulsed sieve plate columns (3) centrifugal contactors. Each one has its own merits and demerits. Mixer settlers score over the other contactors in their simple design and reliable operation over a wide range of process conditions. Air pulsed mixer settlers of different designs are in use in the fuel reprocessing industry. The present paper describes the development of a new type of mixer settler based on ejector as the mixing device. (author). 7 refs., 3 figs., 1 tab.

  17. Performance evaluation of a rectifier column using gamma column scanning

    Directory of Open Access Journals (Sweden)

    Aquino Denis D.

    2017-12-01

    Full Text Available Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.

  18. Single column and two-column H-D-T distillation experiments at TSTA

    International Nuclear Information System (INIS)

    Yamanishi, T.; Yoshida, H.; Hirata, S.; Naito, T.; Naruse, Y.; Sherman, R.H.; Bartlit, J.R.; Anderson, J.L.

    1988-01-01

    Cryogenic distillation experiments were peformed at TSTA with H-D-T system by using a single column and a two-column cascade. In the single column experiment, fundamental engineering data such as the liquid holdup and the HETP were measured under a variety of operational condtions. The liquid holdup in the packed section was about 10 /approximately/ 15% of its superficial volume. The HETP values were from 4 to 6 cm, and increased slightly with the vapor velocity. The reflux ratio had no effect on the HETP. For the wo-colunn experiemnt, dynamic behavior of the cascade was observed. 8 refs., 7 figs., 2 tabs

  19. ON THE ORIGIN OF THE HIGH COLUMN DENSITY TURNOVER IN THE H I COLUMN DENSITY DISTRIBUTION

    International Nuclear Information System (INIS)

    Erkal, Denis; Gnedin, Nickolay Y.; Kravtsov, Andrey V.

    2012-01-01

    We study the high column density regime of the H I column density distribution function and argue that there are two distinct features: a turnover at N H I ≈ 10 21 cm –2 , which is present at both z = 0 and z ≈ 3, and a lack of systems above N H I ≈ 10 22 cm –2 at z = 0. Using observations of the column density distribution, we argue that the H I-H 2 transition does not cause the turnover at N H I ≈ 10 21 cm –2 but can plausibly explain the turnover at N H I ∼> 10 22 cm –2 . We compute the H I column density distribution of individual galaxies in the THINGS sample and show that the turnover column density depends only weakly on metallicity. Furthermore, we show that the column density distribution of galaxies, corrected for inclination, is insensitive to the resolution of the H I map or to averaging in radial shells. Our results indicate that the similarity of H I column density distributions at z = 3 and 0 is due to the similarity of the maximum H I surface densities of high-z and low-z disks, set presumably by universal processes that shape properties of the gaseous disks of galaxies. Using fully cosmological simulations, we explore other candidate physical mechanisms that could produce a turnover in the column density distribution. We show that while turbulence within giant molecular clouds cannot affect the damped Lyα column density distribution, stellar feedback can affect it significantly if the feedback is sufficiently effective in removing gas from the central 2-3 kpc of high-redshift galaxies. Finally, we argue that it is meaningful to compare column densities averaged over ∼ kpc scales with those estimated from quasar spectra that probe sub-pc scales due to the steep power spectrum of H I column density fluctuations observed in nearby galaxies.

  20. Adiabatic packed column supercritical fluid chromatography using a dual-zone still-air column heater.

    Science.gov (United States)

    Helmueller, Shawn C; Poe, Donald P; Kaczmarski, Krzysztof

    2018-02-02

    An approach to conducting SFC separations under pseudo-adiabatic condition utilizing a dual-zone column heater is described. The heater allows for efficient separations at low pressures above the critical temperature by imposing a temperature profile along the column wall that closely matches that for isenthalpic expansion of the fluid inside the column. As a result, the efficiency loss associated with the formation of radial temperature gradients in this difficult region can be largely avoided in packed analytical scale columns. For elution of n-octadecylbenzene at 60 °C with 5% methanol modifier and a flow rate of 3 mL/min, a 250 × 4.6-mm column packed with 5-micron Kinetex C18 particles began to lose efficiency (8% decrease in the number of theoretical plates) at outlet pressures below 142 bar in a traditional forced air oven. The corresponding outlet pressure for onset of excess efficiency loss was decreased to 121 bar when the column was operated in a commercial HPLC column heater, and to 104 bar in the new dual-zone heater operated in adiabatic mode, with corresponding increases in the retention factor for n-octadecylbenzene from 2.9 to 6.8 and 14, respectively. This approach allows for increased retention and efficient separations of otherwise weakly retained analytes. Applications are described for rapid SFC separation of an alkylbenzene mixture using a pressure ramp, and isobaric separation of a cannabinoid mixture. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Study of Pulsed vs. RF Plasma Properties for Surface Processing Applications

    Science.gov (United States)

    Tang, Ricky; Hopkins, Matthew; Barnat, Edward; Miller, Paul

    2015-09-01

    The ability to manipulate the plasma parameters (density, E/N) was previously demonstrated using a double-pulsed column discharge. Experiments extending this to large-surface plasmas of interest to the plasma processing community were conducted. Differences between an audio-frequency pulsed plasma and a radio-frequency (rf) discharge, both prevalent in plasma processing applications, were studied. Optical emission spectroscopy shows higher-intensity emission in the UV/visible range for the pulsed plasma comparing to the rf plasma at comparable powers. Data suggest that the electron energy is higher for the pulsed plasma leading to higher ionization, resulting in increased ion density and ion flux. Diode laser absorption measurements of the concentration of the 1S5 metastable and 1S4 resonance states of argon (correlated with the plasma E/N) provide comparisons between the excitation/ionization states of the two plasmas. Preliminary modeling efforts suggest that the low-frequency polarity switch causes a much more abrupt potential variation to support interesting transport phenomena, generating a ``wave'' of higher temperature electrons leading to more ionization, as well as ``sheath capture'' of a higher density bolus of ions that are then accelerated during polarity switch.

  2. Influence of pressure on the properties of chromatographic columns. II. The column hold-up volume.

    Science.gov (United States)

    Gritti, Fabrice; Martin, Michel; Guiochon, Georges

    2005-04-08

    The effect of the local pressure and of the average column pressure on the hold-up column volume was investigated between 1 and 400 bar, from a theoretical and an experimental point of view. Calculations based upon the elasticity of the solids involved (column wall and packing material) and the compressibility of the liquid phase show that the increase of the column hold-up volume with increasing pressure that is observed is correlated with (in order of decreasing importance): (1) the compressibility of the mobile phase (+1 to 5%); (2) in RPLC, the compressibility of the C18-bonded layer on the surface of the silica (+0.5 to 1%); and (3) the expansion of the column tube (columns packed with the pure Resolve silica (0% carbon), the derivatized Resolve-C18 (10% carbon) and the Symmetry-C18 (20% carbon) adsorbents, using water, methanol, or n-pentane as the mobile phase. These solvents have different compressibilities. However, 1% of the relative increase of the column hold-up volume that was observed when the pressure was raised is not accounted for by the compressibilities of either the solvent or the C18-bonded phase. It is due to the influence of the pressure on the retention behavior of thiourea, the compound used as tracer to measure the hold-up volume.

  3. Compact electron beam focusing column

    Science.gov (United States)

    Persaud, Arun; Leung, Ka-Ngo; Reijonen, Jani

    2001-12-01

    A novel design for an electron beam focusing column has been developed at LBNL. The design is based on a low-energy spread multicusp plasma source which is used as a cathode for electron beam production. The focusing column is 10 mm in length. The electron beam is focused by means of electrostatic fields. The column is designed for a maximum voltage of 50 kV. Simulations of the electron trajectories have been performed by using the 2D simulation code IGUN and EGUN. The electron temperature has also been incorporated into the simulations. The electron beam simulations, column design and fabrication will be discussed in this presentation.

  4. A Non-thermal Pulsed X-Ray Emission of AR Scorpii

    Science.gov (United States)

    Takata, J.; Hu, C.-P.; Lin, L. C. C.; Tam, P. H. T.; Pal, P. S.; Hui, C. Y.; Kong, A. K. H.; Cheng, K. S.

    2018-02-01

    We report the analysis result of UV/X-ray emission from AR Scorpii, which is an intermediate polar (IP) composed of a magnetic white dwarf and an M-type star, with the XMM-Newton data. The X-ray/UV emission clearly shows a large variation over the orbit, and their intensity maximum (or minimum) is located at the superior conjunction (or inferior conjunction) of the M star orbit. The hardness ratio of the X-ray emission shows a small variation over the orbital phase and shows no indication of the absorption by an accretion column. These properties are naturally explained by the emission from the M star surface rather than that from the accretion column on the white dwarf’s (WD) star, which is similar to usual IPs. Additionally, the observed X-ray emission also modulates with the WD’s spin with a pulse fraction of ∼14%. The peak position is aligned in the optical/UV/X-ray band. This supports the hypothesis that the electrons in AR Scorpii are accelerated to a relativistic speed and emit non-thermal photons via the synchrotron radiation. In the X-ray bands, evidence of the power-law spectrum is found in the pulsed component, although the observed emission is dominated by the optically thin thermal plasma emissions with several different temperatures. It is considered that the magnetic dissipation/reconnection process on the M star surface heats up the plasma to a temperature of several keV and also accelerates the electrons to the relativistic speed. The relativistic electrons are trapped in the WD’s closed magnetic field lines by the magnetic mirror effect. In this model, the observed pulsed component is explained by the emissions from the first magnetic mirror point.

  5. Admittance Scanning for Whole Column Detection.

    Science.gov (United States)

    Stamos, Brian N; Dasgupta, Purnendu K; Ohira, Shin-Ichi

    2017-07-05

    Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 μm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 μm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 μm i.d. column) of 500 μM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

  6. The effects of carbide column to swelling potential and Atterberg limit on expansive soil with column to soil drainage

    Science.gov (United States)

    Muamar Rifa'i, Alfian; Setiawan, Bambang; Djarwanti, Noegroho

    2017-12-01

    The expansive soil is soil that has a potential for swelling-shrinking due to changes in water content. Such behavior can exert enough force on building above to cause damage. The use of columns filled with additives such as Calcium Carbide is done to reduce the negative impact of expansive soil behavior. This study aims to determine the effect of carbide columns on expansive soil. Observations were made on swelling and spreading of carbides in the soil. 7 Carbide columns with 5 cm diameter and 20 cm height were installed into the soil with an inter-column spacing of 8.75 cm. Wetting is done through a pipe at the center of the carbide column for 20 days. Observations were conducted on expansive soil without carbide columns and expansive soil with carbide columns. The results showed that the addition of carbide column could reduce the percentage of swelling by 4.42%. Wetting through the center of the carbide column can help spread the carbide into the soil. The use of carbide columns can also decrease the rate of soil expansivity. After the addition of carbide column, the plasticity index value decreased from 71.76% to 4.3% and the shrinkage index decreased from 95.72% to 9.2%.

  7. Thermal process of an air column

    International Nuclear Information System (INIS)

    Lee, F.T.

    1994-01-01

    Thermal process of a hot air column is discussed based on laws of thermodynamics. The kinetic motion of the air mass in the column can be used as a power generator. Alternatively, the column can also function as a exhaust/cooler

  8. Column studies of strontium and cesium migration in a granular geologic material

    International Nuclear Information System (INIS)

    Reynolds, W.D.; Gilham, R.W.; Cherry, J.A.

    1981-06-01

    Infinite-pulse, miscible-displacement experiments were conducted to investigate the applicability of batch Ksub(d) values in the prediction of reactive solute transport during dynamic flow through porous media. Non-reactive tracers (chloride, tritium and oxygen-18), and the reactive tracers (strontium-85 and cesium-137) were passed through a column 5.0 cm long and 6.5 cm in diameter packed with a medium to fine sand. The effluent concentrations of the nonreactive solutes were accurately predicted using the advection-dispersion equation; however, there were large discrepancies between the measured and predicted effluent concentrations for both reactive species. Good agreement was obtained between the measured and computed results by incorporating an empirical isotherm into the advection-dispersion model

  9. Progress on Development of an Airborne Two-Micron IPDA Lidar for Water Vapor and Carbon Dioxide Column Measurements

    Science.gov (United States)

    Singh, Upendra N.; Petros, Mulugeta; Refaat, Tamer F.; Yu, Jirong; Antill, Charles W.; Taylor, Bryant D.; Bowen, Stephen C.; Welters, Angela M.; Remus, Ruben G.; Wong, Teh-Hwa; hide

    2014-01-01

    An airborne 2 micron triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This lidar targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements, simultaneously. Advancements in the development of this IPDA lidar are presented in this paper. Updates on advanced two-micron triple-pulse high-energy laser transmitter will be given including packaging and lidar integration status. In addition, receiver development updates will also be presented. This includes a state-of-the-art detection system integrated at NASA Goddard Space Flight Center. This detection system is based on a newly developed HgCdTe (MCT) electron-initiated avalanche photodiode (e-APD) array. Future plan for IPDA lidar system for ground integration, testing and flight validation will be discussed.

  10. Pulse laser ablation at water-air interface

    Science.gov (United States)

    Utsunomiya, Yuji; Kajiwara, Takashi; Nishiyama, Takashi; Nagayama, Kunihito; Kubota, Shiro

    2010-06-01

    We studied a new pulse laser ablation phenomenon on a liquid surface layer, which is caused by the difference between the refractive indices of the two materials involved. The present study was motivated by our previous study, which showed that laser ablation can occur at the interface between a transparent material and a gas or liquid medium when the laser pulse is focused through the transparent material. In this case, the ablation threshold fluence is reduced remarkably. In the present study, experiments were conducted in water and air in order to confirm this phenomenon for a combination of two fluid media with different refractive indices. This phenomenon was observed in detail by pulse laser shadowgraphy. A high-resolution film was used to record the phenomenon with a Nd:YAG pulse laser with 10-ns duration as a light source. The laser ablation phenomenon on the liquid surface layer caused by a focused Nd:YAG laser pulse with 1064-nm wavelength was found to be followed by the splashing of the liquid surface, inducing a liquid jet with many ligaments. The liquid jet extension velocity was around 1000 m/s in a typical case. The liquid jet decelerated drastically due to rapid atomization at the tips of the ligaments. The liquid jet phenomenon was found to depend on the pulse laser parameters such as the laser fluence on the liquid surface, laser energy, and laser beam pattern. The threshold laser fluence for the generation of a liquid jet was 20 J/cm2. By increasing the incident laser energy with a fixed laser fluence, the laser focused area increased, which eventually led to an increase in the size of the plasma column. The larger the laser energy, the larger the jet size and the longer the temporal behavior. The laser beam pattern was found to have significant effects on the liquid jet’s velocity, shape, and history.

  11. Performance of RC columns with partial length corrosion

    International Nuclear Information System (INIS)

    Wang Xiaohui; Liang Fayun

    2008-01-01

    Experimental and analytical studies on the load capacity of reinforced concrete (RC) columns with partial length corrosion are presented, where only a fraction of the column length was corroded. Twelve simply supported columns were eccentrically loaded. The primary variables were partial length corrosion in tensile or compressive zone and the corrosion level within this length. The failure of the corroded column occurs in the partial length, mainly developed from or located nearby or merged with the longitudinal corrosion cracks. For RC column with large eccentricity, load capacity of the column is mainly influenced by the partial length corrosion in tensile zone; while for RC column with small eccentricity, load capacity of the column greatly decreases due to the partial length corrosion in compressive zone. The destruction of the longitudinally mechanical integrality of the column in the partial length leads to this great reduction of the load capacity of the RC column

  12. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    Science.gov (United States)

    Lim, Heuijin; Hyeok Jeong, Dong; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-04-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun.

  13. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    International Nuclear Information System (INIS)

    Lim, Heuijin; Jeong, Dong Hyeok; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-01-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun

  14. A stochastic view on column efficiency.

    Science.gov (United States)

    Gritti, Fabrice

    2018-03-09

    A stochastic model of transcolumn eddy dispersion along packed beds was derived. It was based on the calculation of the mean travel time of a single analyte molecule from one radial position to another. The exchange mechanism between two radial positions was governed by the transverse dispersion of the analyte across the column. The radial velocity distribution was obtained by flow simulations in a focused-ion-beam scanning electron microscopy (FIB-SEM) based 3D reconstruction from a 2.1 mm × 50 mm column packed with 2 μm BEH-C 18 particles. Accordingly, the packed bed was divided into three coaxial and uniform zones: (1) a 1.4 particle diameter wide, ordered, and loose packing at the column wall (velocity u w ), (2) an intermediate 130 μm wide, random, and dense packing (velocity u i ), and (3) the bulk packing in the center of the column (velocity u c ). First, the validity of this proposed stochastic model was tested by adjusting the predicted to the observed reduced van Deemter plots of a 2.1 mm × 50 mm column packed with 2 μm BEH-C 18 fully porous particles (FPPs). An excellent agreement was found for u i  = 0.93u c , a result fully consistent with the FIB-SEM observation (u i  = 0.95u c ). Next, the model was used to measure u i  = 0.94u c for 2.1 mm × 100 mm column packed with 1.6 μm Cortecs-C 18 superficially porous particles (SPPs). The relative velocity bias across columns packed with SPPs is then barely smaller than that observed in columns packed with FPPs (+6% versus + 7%). u w =1.8u i is measured for a 75 μm × 1 m capillary column packed with 2 μm BEH-C 18 particles. Despite this large wall-to-center velocity bias (+80%), the presence of the thin and ordered wall packing layer has no negative impact on the kinetic performance of capillary columns. Finally, the stochastic model of long-range eddy dispersion explains why analytical (2.1-4.6 mm i.d.) and capillary (columns can all be

  15. Development of Double and Triple-Pulsed 2-micron IPDA Lidars for Column CO2 Measurements

    Science.gov (United States)

    Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta; Refaat, Tamer F.; Remus, Ruben G.; Reithmaier, Karl

    2015-01-01

    Carbon dioxide (CO2) is an important greenhouse gas that significantly contributes to the carbon cycle and globalradiation budget on Earth. CO2 role on Earth’s climate is complicated due to different interactions with various climatecomponents that include the atmosphere, the biosphere and the hydrosphere. Although extensive worldwide efforts formonitoring atmospheric CO2 through various techniques, including in-situ and passive sensors, are taking place highuncertainties exist in quantifying CO2 sources and sinks. These uncertainties are mainly due to insufficient spatial andtemporal mapping of the gas. Therefore it is required to have more rapid and accurate CO2 monitoring with higheruniform coverage and higher resolution. CO2 DIAL operating in the 2-µm band offer better near-surface CO2measurement sensitivity due to the intrinsically stronger absorption lines. For more than 15 years, NASA LangleyResearch Center (LaRC) contributed in developing several 2-?m CO2 DIAL systems and technologies. This paperfocuses on the current development of the airborne double-pulsed and triple-pulsed 2-?m CO2 integrated pathdifferential absorption (IPDA) lidar system at NASA LaRC. This includes the IPDA system development andintegration. Results from ground and airborne CO2 IPDA testing will be presented. The potential of scaling suchtechnology to a space mission will be addressed.

  16. 29 CFR 1926.755 - Column anchorage.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Column anchorage. 1926.755 Section 1926.755 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.755 Column anchorage. (a) General requirements for erection stability. (1) All columns shall be anchored by a minimum of 4 anchor...

  17. Adsorption columns for use in radioimmunoassays

    International Nuclear Information System (INIS)

    1976-01-01

    Adsorption columns are provided which can be utilized in radioimmunoassay systems such as those involving the separation of antibody-antigen complexes from free antigens. The preparation of the columns includes the treatment of retaining substrate material to render it hydrophilic, preparation and degassing of the separation material and loading the column

  18. NMFS Water Column Sonar Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water column sonar data are an important component of fishery independent surveys, habitat studies and other research. NMFS water column sonar data are archived here.

  19. Investigating the Effect of Column Geometry on Separation Efficiency using 3D Printed Liquid Chromatographic Columns Containing Polymer Monolithic Phases.

    Science.gov (United States)

    Gupta, Vipul; Beirne, Stephen; Nesterenko, Pavel N; Paull, Brett

    2018-01-16

    Effect of column geometry on the liquid chromatographic separations using 3D printed liquid chromatographic columns with in-column polymerized monoliths has been studied. Three different liquid chromatographic columns were designed and 3D printed in titanium as 2D serpentine, 3D spiral, and 3D serpentine columns, of equal length and i.d. Successful in-column thermal polymerization of mechanically stable poly(BuMA-co-EDMA) monoliths was achieved within each design without any significant structural differences between phases. Van Deemter plots indicated higher efficiencies for the 3D serpentine chromatographic columns with higher aspect ratio turns at higher linear velocities and smaller analysis times as compared to their counterpart columns with lower aspect ratio turns. Computational fluid dynamic simulations of a basic monolithic structure indicated 44%, 90%, 100%, and 118% higher flow through narrow channels in the curved monolithic configuration as compared to the straight monolithic configuration at linear velocities of 1, 2.5, 5, and 10 mm s -1 , respectively. Isocratic RPLC separations with the 3D serpentine column resulted in an average 23% and 245% (8 solutes) increase in the number of theoretical plates as compared to the 3D spiral and 2D serpentine columns, respectively. Gradient RPLC separations with the 3D serpentine column resulted in an average 15% and 82% (8 solutes) increase in the peak capacity as compared to the 3D spiral and 2D serpentine columns, respectively. Use of the 3D serpentine column at a higher flow rate, as compared to the 3D spiral column, provided a 58% reduction in the analysis time and 74% increase in the peak capacity for the isocratic separations of the small molecules and the gradient separations of proteins, respectively.

  20. Evaluation of Packed Distillation Columns I - Atmospheric Pressure

    National Research Council Canada - National Science Library

    Reynolds, Thaine

    1951-01-01

    .... Four column-packing combinations of the glass columns and four column-packing combinations of the steel columns were investigated at atmospheric pressure using a test mixture of methylcyclohexane...

  1. Center column design of the PLT

    International Nuclear Information System (INIS)

    Citrolo, J.; Frankenberg, J.

    1975-01-01

    The center column of the PLT machine is a secondary support member for the toroidal field coils. Its purpose is to decrease the bending moment at the nose of the coils. The center column design was to have been a stainless steel casting with the toroidal field coils grouped around the casting at installation, trapping it in place. However, the castings developed cracks during fabrication and were unsuitable for use. Installation of the coils proceeded without the center column. It then became necessary to redesign a center column which would be capable of installation with the toroidal field coils in place. The final design consists of three A-286 forgings. This paper discusses the final center column design and the influence that new knowledge, obtained during the power tests, had on the new design

  2. Kinetics of vinyl acetate emulsion polymerization in a pulsed tubular reactor: comparison between experimental and simulation results

    Directory of Open Access Journals (Sweden)

    Sayer C.

    2002-01-01

    Full Text Available A new reactor, the pulsed sieve plate column (PSPC, was developed to perform continuous emulsion polymerization reactions. This reactor combines the enhanced flexibility of tubular reactors with the mixing behavior provided by sieved plates and by the introduction of pulses that is important to prevent emulsion destabilization. The main objective of this work is to study the kinetics of vinyl acetate (VA emulsion polymerization reactions performed in this PSPC. Therefore, both experimental studies and reaction simulations were performed. Results showed that it is possible to obtain high conversions with rather low residence times in the PSPC.

  3. The handedness of historiated spiral columns.

    Science.gov (United States)

    Couzin, Robert

    2017-09-01

    Trajan's Column in Rome (AD 113) was the model for a modest number of other spiral columns decorated with figural, narrative imagery from antiquity to the present day. Most of these wind upwards to the right, often with a congruent spiral staircase within. A brief introductory consideration of antique screw direction in mechanical devices and fluted columns suggests that the former may have been affected by the handedness of designers and the latter by a preference for symmetry. However, for the historiated columns that are the main focus of this article, the determining factor was likely script direction. The manner in which this operated is considered, as well as competing mechanisms that might explain exceptions. A related phenomenon is the reversal of the spiral in a non-trivial number of reproductions of the antique columns, from Roman coinage to Renaissance and baroque drawings and engravings. Finally, the consistent inattention in academic literature to the spiral direction of historiated columns and the repeated publication of erroneous earlier reproductions warrants further consideration.

  4. Column-oriented database management systems

    OpenAIRE

    Možina, David

    2013-01-01

    In the following thesis I will present column-oriented database. Among other things, I will answer on a question why there is a need for a column-oriented database. In recent years there have been a lot of attention regarding a column-oriented database, even if the existence of a columnar database management systems dates back in the early seventies of the last century. I will compare both systems for a database management – a colum-oriented database system and a row-oriented database system ...

  5. Radiotracer Imaging of Sediment Columns

    Science.gov (United States)

    Moses, W. W.; O'Neil, J. P.; Boutchko, R.; Nico, P. S.; Druhan, J. L.; Vandehey, N. T.

    2010-12-01

    Nuclear medical PET and SPECT cameras routinely image radioactivity concentration of gamma ray emitting isotopes (PET - 511 keV; SPECT - 75-300 keV). We have used nuclear medical imaging technology to study contaminant transport in sediment columns. Specifically, we use Tc-99m (T1/2 = 6 h, Eγ = 140 keV) and a SPECT camera to image the bacteria mediated reduction of pertechnetate, [Tc(VII)O4]- + Fe(II) → Tc(IV)O2 + Fe(III). A 45 mL bolus of Tc-99m (32 mCi) labeled sodium pertechnetate was infused into a column (35cm x 10cm Ø) containing uranium-contaminated subsurface sediment from the Rifle, CO site. A flow rate of 1.25 ml/min of artificial groundwater was maintained in the column. Using a GE Millennium VG camera, we imaged the column for 12 hours, acquiring 44 frames. As the microbes in the sediment were inactive, we expected most of the iron to be Fe(III). The images were consistent with this hypothesis, and the Tc-99m pertechnetate acted like a conservative tracer. Virtually no binding of the Tc-99m was observed, and while the bolus of activity propagated fairly uniformly through the column, some inhomogeneity attributed to sediment packing was observed. We expect that after augmentation by acetate, the bacteria will metabolically reduce Fe(III) to Fe(II), leading to significant Tc-99m binding. Imaging sediment columns using nuclear medicine techniques has many attractive features. Trace quantities of the radiolabeled compounds are used (micro- to nano- molar) and the half-lives of many of these tracers are short (Image of Tc-99m distribution in a column containing Rifle sediment at four times.

  6. Transient groundwater chemistry near a river: Effects on U(VI) transport in laboratory column experiments

    Science.gov (United States)

    Yin, Jun; Haggerty, Roy; Stoliker, Deborah L.; Kent, Douglas B.; Istok, Jonathan D.; Greskowiak, Janek; Zachara, John M.

    2011-01-01

    In the 300 Area of a U(VI)-contaminated aquifer at Hanford, Washington, USA, inorganic carbon and major cations, which have large impacts on U(VI) transport, change on an hourly and seasonal basis near the Columbia River. Batch and column experiments were conducted to investigate the factors controlling U(VI) adsorption/desorption by changing chemical conditions over time. Low alkalinity and low Ca concentrations (Columbia River water) enhanced adsorption and reduced aqueous concentrations. Conversely, high alkalinity and high Ca concentrations (Hanford groundwater) reduced adsorption and increased aqueous concentrations of U(VI). An equilibrium surface complexation model calibrated using laboratory batch experiments accounted for the decrease in U(VI) adsorption observed with increasing (bi)carbonate concentrations and other aqueous chemical conditions. In the column experiment, alternating pulses of river and groundwater caused swings in aqueous U(VI) concentration. A multispecies multirate surface complexation reactive transport model simulated most of the major U(VI) changes in two column experiments. The modeling results also indicated that U(VI) transport in the studied sediment could be simulated by using a single kinetic rate without loss of accuracy in the simulations. Moreover, the capability of the model to predict U(VI) transport in Hanford groundwater under transient chemical conditions depends significantly on the knowledge of real-time change of local groundwater chemistry.

  7. Thermally stable dexsil-400 glass capillary columns

    International Nuclear Information System (INIS)

    Maskarinec, M.P.; Olerich, G.

    1980-01-01

    The factors affecting efficiency, thermal stability, and reproducibility of Dexsil-400 glass capillary columns for gas chromatography in general, and for polycyclic aromatic hydrocarbons (PAHs) in particular were investigated. Columns were drawn from Kimble KG-6 (soda-lime) glass or Kimox (borosilicate) glass. All silylation was carried out at 200 0 C. Columns were coated according to the static method. Freshly prepared, degassed solutions of Dexsil-400 in pentane or methylene chloride were used. Thermal stability of the Dexsil 400 columns with respect to gas chromatography/mass spectrometry (GC/MS) were tested. Column-to-column variability is a function of each step in the fabrication of the columns. The degree of etching, extent of silylation, and stationary phase film thickness must be carefully controlled. The variability in two Dexsil-400 capillary column prepared by etching, silylation with solution of hexa methyl disilazone (HMDS), and static coating is shown and also indicates the excellent selectivity of Dexsil-400 for the separation of alkylated aromatic compounds. The wide temperature range of Dexsil-400 and the high efficiency of the capillary columns also allow the analysis of complex mixtures with minimal prefractionation. Direct injection of a coal liquefaction product is given. Analysis by GC/MS indicated the presence of parent PAHs, alkylated PAHs, nitrogen and sulfur heterocycles, and their alkylated derivatives. 4 figures

  8. Determination of carbohydrates using pulsed amperometric detection combined with anion exchange separations

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, W.T.; Pohl, C.A.; Rubin, R.

    1987-06-01

    Carbohydrates, including the monosaccharides commonly found in wood and wood pulp hydrolyzates, are separated by anion exchange chromatography using hydroxide and acetate eluants and are determined using pulsed amperometric detection. The detection method is based on oxidizing the sugars in a flow-through electrochemical cell equipped with a gold working electrode. A repeating cycle of three potentials is used: the first to oxidize the carbohydrates and measure the current generated, and two subsequent pulses to clean the electrode surface of oxidation products. The method is fast, sensitive, and requires no pre-column derivatization. It is applied to a sample of hydrolyzed wood pulp, which can be analyzed after minimal sample preparation. Detection limits are of the order of 1 mg/kg for monosaccharides in a 50 micro L injection. (Refs. 8).

  9. Safety barriers and lighting columns.

    NARCIS (Netherlands)

    Schreuder, D.A.

    1972-01-01

    Problems arising from the sitting of lighting columns on the central reserve are reviewed, and remedial measures such as break-away lighting supports and installation of safety fences on the central reserve on both sides of the lighting columns are examined.

  10. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  11. Geochemical modelling. Column 2: a computer program for simulation of migration

    International Nuclear Information System (INIS)

    Nielsen, O.J.; Carlsen, L.; Bo, P.

    1985-01-01

    COLUMN2 is a 1D FORTRAN77 computer program designed for studies of the effects of various physicochemical processes on migration. It solves the solute transport equation and can take into account dispersion, sorption, ion exchange, first and second order homogeneous chemical reactions. Spatial variations of input pulses and retention factors are possible. The method of solution is based on a finite difference discretion followed by the application of the method of characteristics and two separate grid systems. This report explains the mathematical and numerical methods used, describes the necessary input, contains a number of test examples, provides a listing of the program and explains how to acquire the program, adapt it to other computers and run it. This report serves as a manual for the program

  12. The effect of river pulsing on sedimentation and nutrients in created riparian wetlands.

    Science.gov (United States)

    Nahlik, Amanda M; Mitsch, William J

    2008-01-01

    Sedimentation under pulsed and steady-flow conditions was investigated in two created flow-through riparian wetlands in central Ohio over 2 yr. Hydrologic pulses of river water lasting for 6 to 8 d were imposed on each wetland from January through June during 2004. Mean inflow rates during pulses averaged 52 and 7 cm d(-1) between pulses. In 2005, the wetlands received a steady-flow regime of 11 cm d(-1) with no major hydrologic fluctuations. Thirty-two sediment traps were deployed and sampled once per month in April, May, June, and July for two consecutive years in each wetland. January through March were not sampled in either year due to frozen water surfaces in the wetlands. Gross sedimentation (sedimentation without normalizing for differences between years) was significantly greater in the pulsing study period (90 kg m(-2)) than in the steady-flow study period (64 kg m(-2)). When normalized for different hydrologic and total suspended solid inputs between years, sedimentation for April through July was not significantly different between pulsing and steady-flow study periods. Sedimentation for the 3 mo that received hydrologic pulses (April, May, and June) was significantly lower during pulsing months than in the corresponding steady-flow months. Large fractions of inorganic matter in collected sediments indicated that allochthonous inputs were the main contributor to sedimentation in these wetlands. Organic matter fractions of collected sediments were consistently greater in the steady-flow study period (1.8 g kg(-1)) than in the pulsed study period (1.5 g kg(-1)), consistent with greater primary productivity in the water column during steady-flow conditions.

  13. Investigation of arcing on fiber-formed nanostructured tungsten by pulsed plasma during steady state plasma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yajima, M., E-mail: yajima.miyuki@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, 509-5292 Japan (Japan); Ohno, N. [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kajita, S. [EcoTopia Science Institute, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); De Temmerman, G. [ITER Organization, Route de Vinon sur Verdon, CS 90 046-13067 St Paul Lez Durance Cedex (France); Bystrov, K.; Bardin, S.; Morgan, T.W. [FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, Partner in the Trilateral Euregio Cluster, 5612 AJ Eindhoven (Netherlands); Masuzaki, S. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, 509-5292 Japan (Japan)

    2016-11-15

    Arcing on fiber-formed nanostructured tungsten samples during ELM-like pulses was investigated using the superimposition of high power pulsed plasma on a steady state plasma with hydrogen gas in the linear plasma device Pilot-PSI. The ignition of arcing was observed when the floating potential of the samples was less than −75 V with sufficient heat flux. The surface observation showed that the arc spots were not in the center, but in the peripheral area of the plasma column. Considering the plasma potential profile in the Pilot-PSI, the arcing occurred at the position where the heat flux and the sheath potential drop are sufficiently large.

  14. Heat Transfer Analysis for a Fixed CST Column

    International Nuclear Information System (INIS)

    Lee, S.Y.

    2004-01-01

    In support of a small column ion exchange (SCIX) process for the Savannah River Site waste processing program, a transient two-dimensional heat transfer model that includes the conduction process neglecting the convection cooling mechanism inside the crystalline silicotitanate (CST) column has been constructed and heat transfer calculations made for the present design configurations. For this situation, a no process flow condition through the column was assumed as one of the reference conditions for the simulation of a loss-of-flow accident. A series of the modeling calculations has been performed using a computational heat transfer approach. Results for the baseline model indicate that transit times to reach 130 degrees Celsius maximum temperature of the CST-salt solution column are about 96 hours when the 20-in CST column with 300 Ci/liter heat generation source and 25 degrees Celsius initial column temperature is cooled by natural convection of external air as a primary heat transfer mechanism. The modeling results for the 28-in column equipped with water jacket systems on the external wall surface of the column and water coolant pipe at the center of the CST column demonstrate that the column loaded with 300 Ci/liter heat source can be maintained non-boiling indefinitely. Sensitivity calculations for several alternate column sizes, heat loads of the packed column, engineered cooling systems, and various ambient conditions at the exterior wall of the column have been performed under the reference conditions of the CST-salt solution to assess the impact of those parameters on the peak temperatures of the packed column for a given transient time. The results indicate that a water-coolant pipe at the center of the CST column filled with salt solution is the most effective one among the potential design parameters related to the thermal energy dissipation of decay heat load. It is noted that the cooling mechanism at the wall boundary of the column has significant

  15. NON-LINEAR ANALYSIS OF AN EXPERIMENTAL JOINT OF COLUMN AND BEAMS OF ARMED CONCRETE-STEEL COLUMN FOR FRAME

    Directory of Open Access Journals (Sweden)

    Nelson López

    2017-12-01

    Full Text Available In this research, the nonlinear behavior of a real-scale experimental joint (node is studied, consisting of three reinforced concrete elements, one column and two beams joined to a structural steel column at the upper level. In the numerical analysis the model of the union was analyzed in the inelastic range, this model was elaborated with the finite element program based on fibers, SeismoStruct to analyze as a function of time, the traction and compression efforts in the confined area and not confined area of the concrete column and in the longitudinal reinforcement steel, as well as verification of the design of the base plate that joins the two columns. The results showed that tensile stresses in the unconfined zone surpassed the concrete breaking point, with cracking occurring just below the lower edge of the beams; in the confined area the traction efforts were much lower, with cracks occurring later than in the non-confined area. The concrete column-steel column joint behaved as a rigid node, so the elastic design was consistent with the calculation methodology of base plates for steel columns.

  16. Fabrication of a micrometer Ni–Cu alloy column coupled with a Cu micro-column for thermal measurement

    International Nuclear Information System (INIS)

    Lin, J C; Chang, T K; Yang, J H; Jeng, J H; Lee, D L; Jiang, S B

    2009-01-01

    Micrometer Ni–Cu alloy columns have been fabricated by the micro-anode-guided electroplating (MAGE) process in the citrate bath. The surface morphology and chemical composition of the micro-columns were determined by copper concentration in the bath and by the electrical bias of MAGE. When fabricated in a bath of dilute copper (i.e. 4 mM) at lower voltages (e.g. 3.8 and 4.0 V), the alloy micro-columns revealed uniform diameter and smooth appearance. The alloy composition demonstrated an increase in the wt% ratio of Ni/Cu from 75/25, 80/20, 83/17 to 87/13 with increasing electrical bias from 3.8, 4.0, 4.2 to 4.4 V. However, it decreases from 75/25, 57/43 to 47/53 with increasing copper concentration from 4, 8 to 12 mM in the bath. Citrate plays a role in forming complexes with nickel and copper at similar reduction potentials, thus reducing simultaneously to Ni–Cu alloy. The mechanism for fabricating alloy micro-columns could be delineated on the basis of cathodic polarization of the complexes. A couple of micro-columns were fabricated using MAGE in constructing a pure copper micro-column on the top of a Ni/Cu (at 47/53) alloy micro-column. This micro-thermocouple provides a satisfactory measurement with good sensitivity and precision

  17. Behavior of reinforced concrete columns strenghtened by partial jacketing

    Directory of Open Access Journals (Sweden)

    D. B. FERREIRA

    Full Text Available This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column e PR (reference column. The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.

  18. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  19. Laser beam trapping and propagation in cylindrical plasma columns

    International Nuclear Information System (INIS)

    Feit, M.D.; Fleck, J.A. Jr.

    1976-01-01

    An analysis of the scheme to heat magnetically confined plasma columns to kilovolt temperatures with a laser beam requires consideration of two propagation problems. The first question to be answered is whether stable beam trapping is possible. Since the laser beam creates its own density profile by heating the plasma, the propagation of the beam becomes a nonlinear phenomenon, but not necessarily a stable one. In addition, the electron density at a given time depends on the preceding history of both the medium and the laser pulse. A self-consistent time dependent treatment of the beam propagation and the medium hydrodynamics is consequently required to predict the behavior of the laser beam. Such calculations have been carried out and indicate that propagation of a laser beam in an initially uniform plasma can form a stable filament which alternately focuses and defocuses. An additional question that is discussed is whether diffractive losses associated with long propagation paths are significant

  20. Space-Based CO2 Active Optical Remote Sensing using 2-μm Triple-Pulse IPDA Lidar

    Science.gov (United States)

    Singh, Upendra; Refaat, Tamer; Ismail, Syed; Petros, Mulugeta

    2017-04-01

    Sustained high-quality column CO2 measurements from space are required to improve estimates of regional and global scale sources and sinks to attribute them to specific biogeochemical processes for improving models of carbon-climate interactions and to reduce uncertainties in projecting future change. Several studies show that space-borne CO2 measurements offer many advantages particularly over high altitudes, tropics and southern oceans. Current satellite-based sensing provides rapid CO2 monitoring with global-scale coverage and high spatial resolution. However, these sensors are based on passive remote sensing, which involves limitations such as full seasonal and high latitude coverage, poor sensitivity to the lower atmosphere, retrieval complexities and radiation path length uncertainties. CO2 active optical remote sensing is an alternative technique that has the potential to overcome these limitations. The need for space-based CO2 active optical remote sensing using the Integrated Path Differential Absorption (IPDA) lidar has been advocated by the Advanced Space Carbon and Climate Observation of Planet Earth (A-Scope) and Active Sensing of CO2 Emission over Nights, Days, and Seasons (ASCENDS) studies in Europe and the USA. Space-based IPDA systems can provide sustained, high precision and low-bias column CO2 in presence of thin clouds and aerosols while covering critical regions such as high latitude ecosystems, tropical ecosystems, southern ocean, managed ecosystems, urban and industrial systems and coastal systems. At NASA Langley Research Center, technology developments are in progress to provide high pulse energy 2-μm IPDA that enables optimum, lower troposphere weighted column CO2 measurements from space. This system provides simultaneous ranging; information on aerosol and cloud distributions; measurements over region of broken clouds; and reduces influences of surface complexities. Through the continual support from NASA Earth Science Technology Office

  1. Chromatographic properties PLOT multicapillary columns.

    Science.gov (United States)

    Nikolaeva, O A; Patrushev, Y V; Sidelnikov, V N

    2017-03-10

    Multicapillary columns (MCCs) for gas chromatography make it possible to perform high-speed analysis of the mixtures of gaseous and volatile substances at a relatively large amount of the loaded sample. The study was performed using PLOT MCCs for gas-solid chromatography (GSC) with different stationary phases (SP) based on alumina, silica and poly-(1-trimethylsilyl-1-propyne) (PTMSP) polymer as well as porous polymers divinylbenzene-styrene (DVB-St), divinylbenzene-vinylimidazole (DVB-VIm) and divinylbenzene-ethylene glycol dimethacrylate (DVB-EGD). These MCCs have the efficiency of 4000-10000 theoretical plates per meter (TP/m) and at a column length of 25-30cm can separate within 10-20s multicomponent mixtures of substances belonging to different classes of chemical compounds. The sample amount not overloading the column is 0.03-1μg and depends on the features of a porous layer. Examples of separations on some of the studied columns are considered. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Blind Separation of Two Users Based on User Delays and Optimal Pulse-Shape Design

    Directory of Open Access Journals (Sweden)

    Poor HVincent

    2010-01-01

    Full Text Available A wireless network is considered, in which two spatially distributed users transmit narrow-band signals simultaneously over the same channel using the same power. User separation is achieved by oversampling the received signal and formulating a virtual multiple-input multiple-output (MIMO system based on the resulting polyphase components. Because of oversampling, high correlations can occur between the columns of the virtual MIMO system matrix which can be detrimental to user separation. A novel pulse-shape waveform design is proposed that results in low correlation between the columns of the system matrix, while it exploits all available bandwidth as dictated by a spectral mask. It is also shown that the use of successive interference cancelation in combination with blind source separation further improves the separation performance.

  3. Temporal structure of an electric signal produced upon interaction of radiation from a HF laser with the bottom surface of a water column

    International Nuclear Information System (INIS)

    Andreev, Sergei N; Kazantsev, S Yu; Kononov, I G; Pashinin, Pavel P; Firsov, K N

    2009-01-01

    Generation of an electric signal is investigated when a HF-laser pulse interacts with the lower surface of a water column in a cell with a bottom transparent to laser radiation, while the upper surface of the water column remains open. The electric signal exhibits a temporal structure of two spikes spaced by time τ which is linearly dependent on the laser output energy. It is found that the value of τ (up to 1.3 ms) is an order of magnitude greater than the time during which the vapour pressure in a cavity produced due to the volume explosive boiling of water in the exposed area is greater than the atmospheric pressure. The second spike was determined to appear upon the collapse of the vapour cavity. A mathematical model is constructed that explains the motion of the water column above the vapour cavity taking into account the temporal evolution of the vapour pressure above it. It is shown that the prolonged lifetime of the vapour cavity after the decrease in the vapour pressure down to the atmospheric value is caused by the inertial motion of the water column acquiring the velocity at the initial stage of the cavity expansion. The calculated time of the water column motion agrees well with the experimental time interval between the spikes of an electric signal. (interaction of laser radiation with matter)

  4. Magnetic resonance tomography of the vertebral column and spinal canal

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Brueckmann, H.; Bunke, J.; Giesecke, J.; Heinzerling, J.; Kunze, V.; Mirvis, S.E.; Weidner, A.; Wolf, A.L.

    1992-01-01

    In addition to all the aspects pertinent to diagnostic procedures in the vertebral column and spinal canal this pocket book provides complete coverage of congenital and acquired disorders in the fields of orthopedics, neurology and neurosurgery - including malformations of the spinal canal, degenerative vertebral diseases, tumours, inflammatory changes and vascular diseases, to mention only a few. The authors discuss the question of how image qualities can be influenced and the most information obtained from the different pulse sequences. They outline future development trends and give advice on the reduction of artefacts. The principles that must be adhered to in surgical intervention and nmr imaging for the post-operative assessment of vertebral disk syndromes and tumours are just as important an issue here as is the information the surgeon expects to obtain through diagnostic nmr imaging and the recommendations to be given by the radiologist. (orig.) With 265 figs [de

  5. Investigation of the output pulse characteristics of a 46.9 nm Ar capillary discharge soft x-ray laser

    International Nuclear Information System (INIS)

    Ritucci, A.; Tomassetti, G.; Palladino, L.; Reale, A.; Gaeta, G.; Limongi, T.; Flora, F.; Mezi, L.; Kukhlevsky, S.V.; Kaiser, J.; Faenov, A.; Pikuz, T.; Reale, L.

    2002-01-01

    In this paper, we report on the realization of a capillary discharge soft x-ray laser operating at 46.9 nm pumped by a 30 kA peak value, 150 ns half cycle duration current pulse (corresponding to a mean current slope of about 5 1011 A/s). The slope of the pumping current is sufficiently high to produce the plasma compression and laser amplification on the 3p-3s, J=0-1 transition of Ne-like Ar, in 2.4-4 mm in diameter alumina capillary channels. We have analyzed the output pulse characteristics of the produced laser beam, such as the lasing time and the pulse duration, the saturation and the output pulse energy, the near field image as a function of different experimental parameters. Using the same current pulse, the lasing effect has not been observed in polyacetal capillaries, demonstrating the damning role of the wall capillary ablation in the heating and in the stability of the plasma column during the z-pinch compression

  6. PRTR ion exchange vault column sampling

    International Nuclear Information System (INIS)

    Cornwell, B.C.

    1995-01-01

    This report documents ion exchange column sampling and Non Destructive Assay (NDA) results from activities in 1994, for the Plutonium Recycle Test Reactor (PRTR) ion exchange vault. The objective was to obtain sufficient information to prepare disposal documentation for the ion exchange columns found in the PRTR Ion exchange vault. This activity also allowed for the monitoring of the liquid level in the lower vault. The sampling activity contained five separate activities: (1) Sampling an ion exchange column and analyzing the ion exchange media for purpose of waste disposal; (2) Gamma and neutron NDA testing on ion exchange columns located in the upper vault; (3) Lower vault liquid level measurement; (4) Radiological survey of the upper vault; and (5) Secure the vault pending waste disposal

  7. Field Applications of Gamma Column Scanning Technology

    International Nuclear Information System (INIS)

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  8. Venturi scrubber with integrated separating column for aerosol precipitation and gas sorption

    International Nuclear Information System (INIS)

    Mayinger, F.; Lehner, M.

    1992-01-01

    A concept for a novel, compact process combination in the form of a Venturi scrubber with integrated separating column was developed. The design of the system is such as to meet the boundary conditions encountered in practice. Comprehensive tests were carried through with this high-performance Venturi scrubber in a wide range of parameters, using the superfine dusts titanium dioxide and zinc oxide as test aerosols. Separating efficiency was found to be excellent, especially for multi-stage spray injection of the scrubbing fluid. Multi-stage spray injection achieves a more favourable pulse exchange between gas and fluid so that pressure losses are relatively low even though loading may be high. A provisional experimental set-up is used for further optimization of separating efficiency and pressure loss. (orig.) [de

  9. Pulse pile-up. I: Short pulses

    International Nuclear Information System (INIS)

    Wilkinson, D.H.

    1990-07-01

    The search for rare large pulses against an intense background of smaller ones involves consideration of pulse pile-up. Approximate methods are presented, based on ruin theory, by which the probability of such pile-up may be estimated for pulses of arbitrary form and of arbitrary pulse-height distribution. These methods are checked against cases for which exact solutions are available. The present paper is concerned chiefly with short pulses of finite total duration. (Author) (5 refs., 24 figs.)

  10. Double-pulse laser-induced breakdown spectroscopy analysis of scales from petroleum pipelines

    International Nuclear Information System (INIS)

    o – CEP 24210-346 – Niterói, Rio de Janeiro (Brazil))" data-affiliation=" (Physics Department of University Federal Fluminense, Av. Gal. Milton Tavares de Souza, s/no – CEP 24210-346 – Niterói, Rio de Janeiro (Brazil))" >Cavalcanti, G.H.; Rocha, A.A.; Damasceno, R.N.; Legnaioli, S.; Lorenzetti, G.; Pardini, L.; Palleschi, V.

    2013-01-01

    Pipeline scales from the Campos Bay Petroleum Field near Rio de Janeiro, Brazil have been analyzed by both Raman spectroscopy and by laser-induced breakdown spectroscopy (LIBS) using a double-pulse, calibration-free approach. Elements that are characteristic of petroleum (e.g. C, H, N, O, Mg, Na, Fe and V) were detected, in addition to the Ca, Al, and Si which form the matrix of the scale. The LIBS results were compared with the results of micro-Raman spectroscopy, which confirmed the nature of the incrustations inferred by the LIBS analysis. Results of this preliminary study suggest that diffusion of pipe material into the pipeline intake column plays an important role in the growth of scale. Thanks to the simplicity and relative low cost of equipment and to the fact that no special chemical pre-treatment of the samples is needed, LIBS can offer very fast acquisition of data and the possibility of in situ measurements. LIBS could thus represent an alternative or complementary method for the chemical characterization of the scales by comparison to conventional analytical techniques, such as X-ray diffraction or X-ray fluorescence. - Highlights: • Samples of scales from petroleum pipelines were analyzed using double pulse LIBS. • LIBS is proposed as an alternative method to conventional analytical techniques. • The scale growth is influenced by the product of corrosion in the column of production. • The diffusion of pipe material into the inlay is important for the growth of scale

  11. Picobubble enhanced column flotation of fine coal

    Energy Technology Data Exchange (ETDEWEB)

    Tao, D.; Yu, S.; Parekh, B.K. [University of Kentucky, Lexington, KY (United States). Mining Engineering

    2006-07-01

    The purpose is to study the effectiveness of picobubbles in the column flotation of -28 mesh fine coal particles. A flotation column with a picobubble generator was developed and tested for enhancing the recovery of ultrafine coal particles. The picobubble generator was designed using the hydrodynamic cavitation principle. A metallurgical and a steam coal were tested in the apparatus. The results show that the use of picobubbles in a 2in. flotation column increased the recovery of fine coal by 10 to 30%. The recovery rate varied with feed rate, collector dosage, and other column conditions. 40 refs., 8 figs., 2 tabs.

  12. Exploring the effect of mesopore size reduction on the column performance of silica-based open tubular capillary columns.

    Science.gov (United States)

    Hara, Takeshi; Futagami, Shunta; De Malsche, Wim; Baron, Gino V; Desmet, Gert

    2018-06-01

    We report on a modification in the hydrothermal treatment process of monolithic silica layers used in porous-layered open tubular (PLOT) columns. Lowering the temperature from the customary 95 °C to 80 °C, the size of the mesopores reduced by approximately about 35% from 12-13.5 nm to 7.5-9 nm, while the specific pore volume essentially remains unaltered. This led to an increase of the specific surface area (SA) of about 40%, quasi-independent of the porous layer thickness. The increased surface area provided a corresponding increase in retention, somewhat more (48%) than expected based on the increase in SA for the thin layer columns, and somewhat less than expected (34%) for the thick layer columns. The recipes were applied in 5 μm i.d.-capillaries with a length of 60 cm. Efficiencies under retained conditions amounted up to N = 137,000 for the PLOT column with a layer thickness (d f ) of 300 nm and to N = 109,000 for the PLOT column with d f  = 550 nm. Working under conditions of similar retention, the narrow pore/high SA columns produced with the new 80 °C recipe generated the same number of theoretical plates as the wide pore size/low SA columns produced with the 95 °C recipe. This shows the 80 °C-hydrothermal treatment process allows for an increase in the phase ratio of the PLOT columns without affecting their intrinsic mass transfer properties and separation kinetics. This is further corroborated by the fact that the plate height curves generated with the new and former recipe can both be well-fitted with the Golay-Aris equation without having to change the intra-layer diffusion coefficient. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. [Online enrichment ability of restricted-access column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride].

    Science.gov (United States)

    Zhang, Xiaohui; Wang, Rong; Xie, Hua; Yin, Qiang; Li, Xiaoyun; Jia, Zhengping; Wu, Xiaoyu; Zhang, Juanhong; Li, Wenbin

    2013-05-01

    The online enrichment ability of the restricted-access media (RAM) column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride in plasma was studied. The RAM-HPLC system consisted of an RAM column as enrichment column and a C18 column as analytical column coupled via the column switching technique. The effects of the injection volume on the peak area and the systematic pressure were studied. When the injection volume was less than 100 microL, the peak area increased with the increase of the injection volume. However, when the injection volume was more than 80 microL, the pressure of whole system increased obviously. In order to protect the whole system, 80 microL was chosen as the maximum injection volume. The peak areas of ordinary injection and the large volume injection showed a good linear relationship. The enrichment ability of RAM-HPLC system was satisfactory. The system was successfully used for the separation and detection of the trace benazepril hydrochloride in rat plasma after its administration. The sensitivity of HPLC can be improved by RAM pre-enrichment. It is a simple and economic measurement method.

  14. Response of steel box columns in fire conditions

    Directory of Open Access Journals (Sweden)

    Mahmood Yahyai

    2017-05-01

    Full Text Available Effect of elevated temperatures on the mechanical properties of steel, brings the importance of investigating the effect of fire on the steel structures anxiously. Columns, as the main load-carrying part of a structure, can be highly vulnerable to the fire. In this study, the behavior of steel gravity columns with box cross section exposed to fire has been investigated. These kinds of columns are widely used in common steel structures design in Iran. In current study, the behavior of such columns in fire conditions is investigated through the finite element method. To perform this, the finite element model of a steel column which has been previously tested under fire condition, was prepared. Experimental loading and boundary conditions were considered in the model and was analyzed. Results were validated by experimental data and various specimens of gravity box columns were designed according to the Iran’s steel buildings code, and modeled and analyzed using Abaqus software. The effect of width to thickness ratio of column plates, the load ratio and slenderness on the ultimate strength of the column was investigated, and the endurance time was estimated under ISO 834 standard fire curve. The results revealed that an increase in width to thickness ratio and load ratio leads to reduction of endurance time and the effect of width to thickness ratio on the ultimate strength of the column decreases with temperature increase.

  15. Ductility of reinforced concrete columns confined with stapled strips

    International Nuclear Information System (INIS)

    Tahir, M.F.; Khan, Q.U.Z.; Shabbir, F.; Sharif, M.B.; Ijaz, N.

    2015-01-01

    Response of three 150x150x450mm short reinforced concrete (RC) columns confined with different types of confining steel was investigated. Standard stirrups, strips and stapled strips, each having same cross-sectional area, were employed as confining steel around four comer column bars. Experimental work was aimed at probing into the affect of stapled strip confinement on post elastic behavior and ductility level under cyclic axial load. Ductility ratios, strength enhancement factor and core concrete strengths were compared to study the affect of confinement. Results indicate that strength enhancement in RC columns due to strip and stapled strip confinement was not remarkable as compared to stirrup confined column. It was found that as compared to stirrup confined column, stapled strip confinement enhanced the ductility of RC column by 183% and observed axial capacity of stapled strip confined columns was 41 % higher than the strip confined columns. (author)

  16. Retrofit of distillation columns in biodiesel production plants

    International Nuclear Information System (INIS)

    Nguyen, Nghi; Demirel, Yasar

    2010-01-01

    Column grand composite curves and the exergy loss profiles produced by the Column-Targeting Tool of the Aspen Plus simulator are used to assess the performance of the existing distillation columns, and reduce the costs of operation by appropriate retrofits in a biodiesel production plant. Effectiveness of the retrofits is assessed by means of thermodynamics and economic improvements. We have considered a biodiesel plant utilizing three distillation columns to purify biodiesel (fatty acid methyl ester) and byproduct glycerol as well as reduce the waste. The assessments of the base case simulation have indicated the need for modifications for the distillation columns. For column T202, the retrofits consisting of a feed preheating and reflux ratio modification have reduced the total exergy loss by 47%, while T301 and T302 columns exergy losses decreased by 61% and 52%, respectively. After the retrofits, the overall exergy loss for the three columns has decreased from 7491.86 kW to 3627.97 kW. The retrofits required a fixed capital cost of approximately $239,900 and saved approximately $1,900,000/year worth of electricity. The retrofits have reduced the consumption of energy considerably, and leaded to a more environmentally friendly operation for the biodiesel plant considered.

  17. Interpretation of the lime column penetration test

    International Nuclear Information System (INIS)

    Liyanapathirana, D S; Kelly, R B

    2010-01-01

    Dry soil mix (DSM) columns are used to reduce the settlement and to improve the stability of embankments constructed on soft clays. During construction the shear strength of the columns needs to be confirmed for compliance with technical assumptions. A specialized blade shaped penetrometer known as the lime column probe, has been developed for testing DSM columns. This test can be carried out as a pull out resistance test (PORT) or a push in resistance test (PIRT). The test is considered to be more representative of average column shear strength than methods that test only a limited area of the column. Both PORT and PIRT tests require empirical correlations of measured resistance to an absolute measure of shear strength, in a similar manner to the cone penetration test. In this paper, finite element method is used to assess the probe factor, N, for the PORT test. Due to the large soil deformations around the probe, an Arbitrary Lagrangian Eulerian (ALE) based finite element formulation has been used. Variation of N with rigidity index and the friction at the probe-soil interface are investigated to establish a range for the probe factor.

  18. Behaviour of FRP confined concrete in square columns

    OpenAIRE

    Diego Villalón, Ana de; Arteaga Iriarte, Ángel; Fernandez Gomez, Jaime Antonio; Perera Velamazán, Ricardo; Cisneros, Daniel

    2015-01-01

    A significant amount of research has been conducted on FRP-confined circular columns, but much less is known about rectangular/square columns in which the effectiveness of confinement is much reduced. This paper presents the results of experimental investigations on low strength square concrete columns confined with FRP. Axial compression tests were performed on ten intermediate size columns. The tests results indicate that FRP composites can significantly improve the bearing capacity and duc...

  19. Numerical Simulations of Settlement of Jet Grouting Columns

    Directory of Open Access Journals (Sweden)

    Juzwa Anna

    2016-03-01

    Full Text Available The paper presents the comparison of results of numerical analyses of interaction between group of jet grouting columns and subsoil. The analyses were conducted for single column and groups of three, seven and nine columns. The simulations are based on experimental research in real scale which were carried out by authors. The final goal for the research is an estimation of an influence of interaction between columns working in a group.

  20. Pulsed, atmospheric pressure plasma source for emission spectrometry

    Science.gov (United States)

    Duan, Yixiang; Jin, Zhe; Su, Yongxuan

    2004-05-11

    A low-power, plasma source-based, portable molecular light emission generator/detector employing an atmospheric pressure pulsed-plasma for molecular fragmentation and excitation is described. The average power required for the operation of the plasma is between 0.02 W and 5 W. The features of the optical emission spectra obtained with the pulsed plasma source are significantly different from those obtained with direct current (dc) discharge higher power; for example, strong CH emission at 431.2 nm which is only weakly observed with dc plasma sources was observed, and the intense CN emission observed at 383-388 nm using dc plasma sources was weak in most cases. Strong CN emission was only observed using the present apparatus when compounds containing nitrogen, such as aniline were employed as samples. The present apparatus detects dimethylsulfoxide at 200 ppb using helium as the plasma gas by observing the emission band of the CH radical. When coupled with a gas chromatograph for separating components present in a sample to be analyzed, the present invention provides an apparatus for detecting the arrival of a particular component in the sample at the end of the chromatographic column and the identity thereof.

  1. Strengthening of Steel Columns under Load: Torsional-Flexural Buckling

    Directory of Open Access Journals (Sweden)

    Martin Vild

    2016-01-01

    Full Text Available The paper presents experimental and numerical research into the strengthening of steel columns under load using welded plates. So far, the experimental research in this field has been limited mostly to flexural buckling of columns and the preload had low effect on the column load resistance. This paper focuses on the local buckling and torsional-flexural buckling of columns. Three sets of three columns each were tested. Two sets corresponding to the base section (D and strengthened section (E were tested without preloading and were used for comparison. Columns from set (F were first preloaded to the load corresponding to the half of the load resistance of the base section (D. Then the columns were strengthened and after they cooled, they were loaded to failure. The columns strengthened under load (F had similar average resistance as the columns welded without preloading (E, meaning the preload affects even members susceptible to local buckling and torsional-flexural buckling only slightly. This is the same behaviour as of the tested columns from previous research into flexural buckling. The study includes results gained from finite element models of the problem created in ANSYS software. The results obtained from the experiments and numerical simulations were compared.

  2. Realtime aspects of pulse-to-pulse modulation

    International Nuclear Information System (INIS)

    Steiner, R.; Riedel, C.; Roesch, W.

    1992-01-01

    The pulse-to-pulse modulation of the SIS-ESR control system is described. Fast response to operator interaction and to changes in process conditions is emphasized as well as the essential part played by the timing system in pulse-to-pulse modulation. (author)

  3. Collapse of tall granular columns in fluid

    Science.gov (United States)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  4. CUB DI (Deionization) column control system

    International Nuclear Information System (INIS)

    Seino, K.C.

    1999-01-01

    For the old MR (Main Ring), deionization was done with two columns in CUB, using an ion exchange process. Typically 65 GPM of LCW flew through a column, and the resistivity was raised from 3 Mohm-cm to over 12 Mohm-cm. After a few weeks, columns lost their effectiveness and had to be regenerated in a process involving backwashing and adding hydrochloric acid and sodium hydroxide. For normal MR operations, LCW returned from the ring and passed through the two columns in parallel for deionization, although the system could have been operated satisfactorily with only one in use. A 3000 gallon reservoir (the Spheres) provided a reserve of LCW for allowing water leaks and expansions in the MR. During the MI (Main Injector) construction period, the third DI column was added to satisfy requirements for the MI. When the third column was added, the old regeneration controller was replaced with a new controller based on an Allen-Bradley PLC (i.e., SLC-5/04). The PLC is widely used and well documented, and therefore it may allow us to modify the regeneration programs in the future. In addition to the above regeneration controller, the old control panels (which were used to manipulate pumps and valves to supply LCW in Normal mode and to do Int. Recir. (Internal Recirculation) and Makeup) were replaced with a new control system based on Sixtrak Gateway and I/O modules. For simplicity, the new regeneration controller is called as the US Filter system, and the new control system is called as the Fermilab system in this writing

  5. NOx retention in scrubbing column

    International Nuclear Information System (INIS)

    Nakazone, A.K.; Costa, R.E.; Lobao, A.S.T.; Matsuda, H.T.; Araujo, B.F.

    1988-07-01

    During the UO 2 dissolution in nitric acid, some different species of NO x are released. The off gas can either be refluxed to the dissolver or be released and retained on special columns. The final composition of the solution is the main parameter to take in account. A process for nitrous gases retention using scubber columns containing H 2 O or diluted HNO 3 is presented. Chemiluminescence measurement was employed to NO x evalution before and after scrubbing. Gas flow, temperature, residence time are the main parameters considered in this paper. For the dissolution of 100g UO 2 in 8M nitric acid, a 6NL/h O 2 flow was the best condition for the NO/NO 2 oxidation with maximum adsorption in the scrubber columns. (author) [pt

  6. ANALYSIS OF TRICKLE BED AND PACKED BUBBLE COLUMN BIOREACTORS FOR COMBINED CARBON OXIDATION AND NITRIFICATION

    Directory of Open Access Journals (Sweden)

    Iliuta I.

    2002-01-01

    Full Text Available Biological removal of nitrogen and carbon by combined nitrification-oxidation in gas-liquid trickle-bed reactors (TBRs and packed bubble columns (PBCs was analyzed theoretically using a transient two-dimensional model. The model describes TBR and PBC performances at steady state as well as their transient response to a pulse or step increase in inlet methanol and NH4+-nitrogen concentrations. The hydrodynamic parameters were determined from residence time distribution measurements, using an imperfect pulse method for time-domain analysis of nonideal pulse tracer response. A transient diffusion model of the tracer in the porous particle coupled with the piston-dispersion-exchange model was used to interpret the residence time distribution curves obtained. Gas-liquid mass transfer parameters were determined by a stationary method based on the least-squares fit of the calculated concentration profiles in gas phase to the experimental values. Analysis of steady-state performances showed that under like operating conditions, the TBR outperforms the PBC in terms of conversions. A pulse change in the inlet methanol or NH4+-nitrogen concentration causes a negligible transient change in the outlet methanol concentration and a negligible or high transient change in the outlet NH4+-nitrogen concentration. A step change in the inlet methanol concentration causes the negligible transient change in the methanol outlet concentration and a relatively important transient change in the NH4+-nitrogen outlet concentration. A step increase in the NH4+-nitrogen inlet concentration induces a drastic transient change in the NH4+-nitrogen outlet concentration but a negligible transient change in the methanol outlet concentration.

  7. Modalization in the Political Column of Tempo Magazine

    OpenAIRE

    Rahmah, Maria Betti Sinaga and

    2017-01-01

    The study focuses on analyzing the use of modalization in the Political Column of Tempo Magazine. The objectives were to find out the type of modalization and to describe the use of modalization in the Political Column of Tempo magazine. The data were taken from Political Column of Tempo magazine published in June and July 2017. The source of data was Political Column in Tempo magazine. The data analysis applied descriptive qualitative research. There were 135 clauses which contained Modaliza...

  8. Pulsed rf excited spectrometer having improved pulse width control

    International Nuclear Information System (INIS)

    1977-01-01

    RF excitation for a spectrometer is obtained by pulse width modulating an RF carrier to produce the desired broadband RF exciting spectrum. The RF excitation includes a train of composite RF pulses, each composite pulse having a primary pulse portion of a first RF phase and a second pulse portion of a second RF phase opposite that of the first. In this manner, the finite rise and fall times of the primary pulse portion are compensated for by the corresponding rise and fall times of the secondary pulse portion. The primary pulse portion is lengthened by an amount equal to the secondary pulse portion so that the secondary pulse portion cancels the added primary pulse portion. In a spectrometer, the compensating second pulse component removes certain undesired side bands of the RF excitation caused by the finite rise and fall times of the applied RF pulses. The compensating second pulse component removes certain undesired side bands associated with each of the resonant lines of the excited resonance spectrum of the sample under analysis, particularly for wide band RF excitation

  9. Column, particularly extraction column, for fission and/or breeder materials

    International Nuclear Information System (INIS)

    Vietzke, H.; Pirk, H.

    1980-01-01

    An absorber rod with a B 4 C insert is situated in the long extraction column for a uranyl nitrate solution or a plutonium nitrate solution. The geometrical dimensions are designed for a high throughput with little corrosion. (DG) [de

  10. Posterior column reconstruction improves fusion rates at the level of osteotomy in three-column posterior-based osteotomies.

    Science.gov (United States)

    Lewis, Stephen J; Mohanty, Chandan; Gazendam, Aaron M; Kato, So; Keshen, Sam G; Lewis, Noah D; Magana, Sofia P; Perlmutter, David; Cape, Jennifer

    2018-03-01

    To determine the incidence of pseudarthrosis at the osteotomy site after three-column spinal osteotomies (3-COs) with posterior column reconstruction. 82 consecutive adult 3-COs (66 patients) with a minimum of 2-year follow-up were retrospectively reviewed. All cases underwent posterior 3-COs with two-rod constructs. The inferior facets of the proximal level were reduced to the superior facets of the distal level. If that was not possible, a structural piece of bone graft either from the local resection or a local rib was slotted in the posterior column defect to re-establish continual structural posterior bone across the lateral margins of the resection. No interbody cages were used at the level of the osteotomy. There were 34 thoracic osteotomies, 47 lumbar osteotomies and one sacral osteotomy with a mean follow-up of 52 (24-126) months. All cases underwent posterior column reconstructions described above and the addition of interbody support or additional posterior rods was not performed for fusion at the osteotomy level. Among them, 29 patients underwent one or more revision surgeries. There were three definite cases of pseudarthrosis at the osteotomy site (4%). Six revisions were also performed for pseudarthrosis at other levels. Restoration of the structural integrity of the posterior column in three-column posterior-based osteotomies was associated with > 95% fusion rate at the level of the osteotomy. Pseudarthrosis at other levels was the second most common reason for revision following adjacent segment disease in the long-term follow-up.

  11. Study of the signal formation in single-type column 3D silicon detectors

    International Nuclear Information System (INIS)

    Piemonte, Claudio; Boscardin, Maurizio; Bosisio, Luciano; Dalla Betta, Gian-Franco; Pozza, Alberto; Ronchin, Sabina; Zorzi, Nicola

    2007-01-01

    Because of their superior radiation resistance, three-dimensional (3D) silicon sensors are receiving more and more interest for application in the innermost layers of tracker systems for experiments running in very high luminosity colliders. Their short electrode distance allows for both a low depletion voltage and a high charge collection efficiency even at extremely high radiation fluences. In order to fully understand the properties of a 3D detector, a thorough characterization of the signal formation mechanism is of paramount importance. In this work the shape of the current induced by localized and uniform charge depositions in a single-type column 3D detector is studied. A first row estimation is given applying the Ramo theorem, then a more complete TCAD simulation is used to provide a more realistic pulse shape

  12. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    Science.gov (United States)

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte). Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Bipolar pulse generator for intense pulsed ion beam accelerator

    International Nuclear Information System (INIS)

    Ito, H.; Igawa, K.; Kitamura, I.; Masugata, K.

    2007-01-01

    A new type of pulsed ion beam accelerator named ''bipolar pulse accelerator'' (BPA) has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator for the bipolar pulse experiment, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the first experimental result of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PFL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time

  14. Water hammer with column separation : a historical review

    NARCIS (Netherlands)

    Bergant, A.; Simpson, A.R.; Tijsseling, A.S.

    2006-01-01

    Column separation refers to the breaking of liquid columns in fully filled pipelines. This may occur in a water-hammer event when the pressure in a pipeline drops to the vapor pressure at specific locations such as closed ends, high points or knees (changes in pipe slope). The liquid columns are

  15. Influence of Power Pulse Parameters on the Microstructure and Properties of the AlCrN Coatings by a Modulated Pulsed Power Magnetron Sputtering

    Directory of Open Access Journals (Sweden)

    Jun Zheng

    2017-11-01

    Full Text Available In this study, AlCrN coatings were deposited using modulated pulsed power magnetron sputtering (MPPMS with different power pulse parameters by varying modulated pulsed power (MPP charge voltages (350 to 550 V. The influence of power pulse parameters on the microstructure, mechanical properties and thermal stability of the coatings was investigated. The results indicated that all the AlCrN coatings exhibited a dense columnar microstructure. Higher charge voltage could facilitate a denser coating microstructure. As the charge voltage increased up to 450 V or higher, the microvoids along the column boundaries disappeared and the coatings became fully dense. The main phase in the AlCrN coatings was the c-(Al, CrN solid solution phase with NaCl-type phase structure. A diffraction peak of the h-AlN phase was detected at a 2θ of around 33°, when the charge voltage was higher than 500 V. The hardness of the AlCrN coatings varied as a function of charge voltage. The maximum value of the hardness (30.8 GPa was obtained at 450 V. All the coatings showed good thermal stability and maintained their structure and mechanical properties unchanged up to 800 °C during vacuum annealing. However, further increasing the annealing temperature to 1000 °C resulted in apparent change in the microstructure and decrease in the hardness. The charge voltages also showed a significant influence on the high-temperature tribological behavior of the coatings. The coating deposited at the charge voltage of 550 V exhibited excellent tribological properties with a low friction coefficient.

  16. Monitoring changes in soil water content on adjustable soil slopes of a soil column using time domain reflectometry (TDR) techniques

    International Nuclear Information System (INIS)

    Wan Zakaria Wan Muhd Tahir; Lakam Anak Mejus; Johari Abdul Latif

    2004-01-01

    Time Domain Reflectometry (TDR) is one of non-destructive methods and widely used in hydrology and soil science for accurate and flexible measurement of soil water content The TDR technique is based on measuring the dielectric constant of soil from the propagation of an electromagnetic pulse traveling along installed probe rods (parallel wire transmission line). An adjustable soil column i.e., 80 cm (L) x 35 cm (H) x 44 cm (W) instrumented with six pairs of vertically installed CS615 reflectometer probes (TDR rods) was developed and wetted under a laboratory simulated rainfall and their sub-surface moisture variations as the slope changes were monitored using TDR method Soil samples for gravimetric determination of water content, converted to a volume basis were taken at selected times and locations after the final TDR reading for every slope change made of the soil column Comparisons of water contents by TDR with those from grawmetric samples at different slopes of soil column were examined. The accuracy was found to be comparable and to some extent dependent upon the variability of the soil. This study also suggests that the response of slope (above 20 degrees) to the gradual increase in water content profile may cause soil saturation faster and increased overland flow (runoff especially on weak soil conditions

  17. HPLC-CUPRAC post-column derivatization method for the determination of antioxidants: a performance comparison between porous silica and core-shell column packing.

    Science.gov (United States)

    Haque, Syed A; Cañete, Socrates Jose P

    2018-01-01

    An HPLC method employing a post-column derivatization strategy using the cupric reducing antioxidant capacity reagent (CUPRAC reagent) for the determining antioxidants in plant-based materials leverages the separation capability of regular HPLC approaches while allowing for detection specificity for antioxidants. Three different column types, namely core-shell and porous silica including two chemically different core-shell materials (namely phenyl-hexyl and C18), were evaluated to assess potential improvements that could be attained by changing from a porous silica matrix to a core-shell matrix. Tea extracts were used as sample matrices for the evaluation specifically looking at catechin and epigallocatechin gallate (EGCG). Both the C18 and phenyl-hexyl core-shell columns showed better performance compared to the C18 porous silica one in terms of separation, peak shape, and retention time. Among the two core-shell materials, the phenyl-hexyl column showed better resolving power compared to the C18 column. The CUPRAC post-column derivatization method can be improved using core-shell columns and suitable for quantifying antioxidants, exemplified by catechin and EGCG, in tea samples.

  18. Propagation and diffusion of a plasma column in a magnetic field; Propagation et diffusion d'une colonne de plasma dans un champ magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Bottiglioni, F; Coutant, J; Gadda, E; Prevot, F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1966-12-01

    A plasma column is created in a magnetic field by longitudinal diffusion from a low-pressure pulsed discharge in hydrogen. Depending on the discharge conditions, two regimes are obtained in which the gas pumping speed has a different effect upon the plasma density in the column. Calculations are presented which can explain this effect by a difference in the transverse diffusion coefficient. (authors) [French] On forme une colonne de plasma dans un champ magnetique par diffusion longitudinale a partir d'une decharge puisee dans l'hydrogene a basse pression. Selon les conditions de la decharge on observe deux regimes differents pour lesquels le pompage du gaz neutre a un effet different sur la densite resultante du plasma dans la colonne. On presente des calculs qui peuvent expliquer cet effet par une difference dans la diffusion transversale du plasma. (auteurs)

  19. Application of a Fast Separation Method for Anti-diabetics in Pharmaceuticals Using Monolithic Column: Comparative Study With Silica Based C-18 Particle Packed Column.

    Science.gov (United States)

    Hemdan, A; Abdel-Aziz, Omar

    2018-04-01

    Run time is a predominant factor in HPLC for quality control laboratories especially if there is large number of samples have to be analyzed. Working at high flow rates cannot be attained with silica based particle packed column due to elevated backpressure issues. The use of monolithic column as an alternative to traditional C-18 column was tested for fast separation of pharmaceuticals, where the results were very competitive. The performance comparison of both columns was tested for separation of anti-diabetic combination containing Metformin, Pioglitazone and Glimepiride using Gliclazide as an internal standard. Working at high flow rates with less significant backpressure was obtained with the monolithic column where the run time was reduced from 6 min in traditional column to only 1 min in monolithic column with accepted resolution. The structure of the monolith contains many pores which can adapt the high flow rate of the mobile phase. Moreover, peak symmetry and equilibration time were more efficient with monolithic column.

  20. Validation of double-pulse 1572 nm integrated path differential absorption lidar measurement of carbon dioxide

    Science.gov (United States)

    Du, Juan; Liu, Jiqiao; Bi, Decang; Ma, Xiuhua; Hou, Xia; Zhu, Xiaolei; Chen, Weibiao

    2018-04-01

    A ground-based double-pulse 1572 nm integrated path differential absorption (IPDA) lidar was developed for carbon dioxide (CO2) column concentrations measurement. The lidar measured the CO2 concentrations continuously by receiving the scattered echo signal from a building about 1300 m away. The other two instruments of TDLAS and in-situ CO2 analyzer measured the CO2 concentrations on the same time. A CO2 concentration measurement of 430 ppm with 1.637 ppm standard error was achieved.

  1. Preparation and evaluation of 400μm I.D. polymer-based hydrophilic interaction chromatography monolithic columns with high column efficiency.

    Science.gov (United States)

    Liu, Chusheng; Li, Haibin; Wang, Qiqin; Crommen, Jacques; Zhou, Haibo; Jiang, Zhengjin

    2017-08-04

    The quest for higher column efficiency is one of the major research areas in polymer-based monolithic column fabrication. In this research, two novel polymer-based HILIC monolithic columns with 400μm I.D.×800μm O.D. were prepared based on the thermally initiated co-polymerization of N,N-dimethyl-N-(3-methacrylamidopropyl)-N-(3-sulfopropyl) ammonium betaine (SPP) and ethylene glycol dimethacrylate (EDMA) or N,N'-methylenebisacrylamide (MBA). In order to obtain a satisfactory performance in terms of column permeability, mechanical stability, efficiency and selectivity, the polymerization parameters were systematically optimized. Column efficiencies as high as 142, 000 plates/m and 120, 000 plates/m were observed for the analysis of neutral compounds at 0.6mm/s on the poly(SPP-co-MBA) and poly(SPP-co-EDMA) monoliths, respectively. Furthermore, the Van Deemter plots for thiourea on the two monoliths were compared with that on a commercial silica based ZIC-HILIC column (3.5μm, 200Å, 150mm×300μm I.D.) using ACN/H 2 O (90/10, v/v) as the mobile phase at room temperature. It was noticeable that the Van Deemter curves for both monoliths, particularly the poly(SPP-co-MBA) monolith, are significantly flatter than that obtained for the ZIC-HILIC column, which indicates that in spite of their larger internal diameters, they yield better overall efficiency, with less peak dispersion, across a much wider range of usable linear velocities. A clearly better separation performance was also observed for nucleobases, nucleosides, nucleotides and small peptides on the poly(SPP-co-MBA) monolith compared to the ZIC-HILIC column. It is particularly worth mentioning that these 400μm I.D. polymer-based HILIC monolithic columns exhibit enhanced mechanical strength owing to the thicker capillary wall of the fused-silica capillaries. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. HEAT TRANSFER ANALYSIS FOR FIXED CST AND RF COLUMNS

    International Nuclear Information System (INIS)

    Lee, S

    2007-01-01

    In support of a small column ion exchange (SCIX) process for the Savannah River Site waste processing program, transient and steady state two-dimensional heat transfer models have been constructed for columns loaded with cesium-saturated crystalline silicotitanate (CST) or spherical Resorcinol-Formaldehyde (RF) beads and 6 molar sodium tank waste supernate. Radiolytic decay of sorbed cesium results in heat generation within the columns. The models consider conductive heat transfer only with no convective cooling and no process flow within the columns (assumed column geometry: 27.375 in ID with a 6.625 in OD center-line cooling pipe). Heat transfer at the column walls was assumed to occur by natural convection cooling with 35 C air. A number of modeling calculations were performed using this computational heat transfer approach. Minimal additional calculations were also conducted to predict temperature increases expected for salt solution processed through columns of various heights at the slowest expected operational flow rate of 5 gpm. Results for the bounding model with no process flow and no active cooling indicate that the time required to reach the boiling point of ∼130 C for a CST-salt solution mixture containing 257 Ci/liter of Cs-137 heat source (maximum expected loading for SCIX applications) at 35 C initial temperature is about 6 days. Modeling results for a column actively cooled with external wall jackets and the internal coolant pipe (inlet coolant water temperature: 25 C) indicate that the CST column can be maintained non-boiling under these conditions indefinitely. The results also show that the maximum temperature of an RF-salt solution column containing 133 Ci/liter of Cs-137 (maximum expected loading) will never reach boiling under any conditions (maximum predicted temperature without cooling: 88 C). The results indicate that a 6-in cooling pipe at the center of the column provides the most effective cooling mechanism for reducing the maximum

  3. Novel field emission SEM column with beam deceleration technology

    International Nuclear Information System (INIS)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-01-01

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications

  4. Novel field emission SEM column with beam deceleration technology

    Energy Technology Data Exchange (ETDEWEB)

    Jiruše, Jaroslav; Havelka, Miloslav; Lopour, Filip

    2014-11-15

    A novel field-emission SEM column has been developed that features Beam Deceleration Mode, high-probe current and ultra-fast scanning. New detection system in the column is introduced to detect true secondary electron signal. The resolution power at low energy was doubled for conventional SEM optics and moderately improved for immersion optics. Application examples at low landing energies include change of contrast, imaging of non-conductive samples and thin layers. - Highlights: • A novel field-emission SEM column has been developed. • Implemented beam deceleration improves the SEM resolution at 1 keV two times. • New column maintains high analytical potential and wide field of view. • Detectors integrated in the column allow gaining true SE and BE signal separately. • Performance of the column is demonstrated on low energy applications.

  5. Pulse on pulse: modulation and signification in Rafael Lozano-Hemmer's Pulse Room

    Directory of Open Access Journals (Sweden)

    Merete Carlson

    2012-06-01

    Full Text Available This article investigates the relation between signifying processes and non-signifying material dynamism in the installation Pulse Room (2006 by Mexican Canadian artist Rafael Lozano-Hemmer. In Pulse Room the sense of pulse is ambiguous. Biorhythms are transmitted from the pulsing energy of the visitor's beating heart to the flashing of a fragile light bulb, thereby transforming each light bulb into a register of individual life. But at the same time the flashing light bulbs together produce a chaotically flickering light environment composed by various layers of repetitive rhythms, a vibrant and pulsating “room”. Hence, the visitor in Pulse Room is invited into a complex scenario that continuously oscillates between various aspects of signification (the light bulbs representing individual lives; the pulse itself as the symbolic “rhythm of life” and instants of pure material processuality (flickering light bulbs; polyrhythmic layers. Taking our point of departure in a discussion of Gilles Deleuze's concepts of modulation and signaletic material in relation to electronic media, we examine how the complex orchestration of pulsation between signification and material modulation produces a multilayered sense of time and space that is central to the sensory experience of Pulse Room as a whole. Pulse Room is, at the very same time, a relational subject–object intimacy and an all-encompassing immersive environment modulating continuously in real space-time.

  6. The design of a new concept chromatography column.

    Science.gov (United States)

    Camenzuli, Michelle; Ritchie, Harald J; Ladine, James R; Shalliker, R Andrew

    2011-12-21

    Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.

  7. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  8. Dynamic effects of diabatization in distillation columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    The dynamic effects of diabatization in distillation columns are investigated in simulation emphasizing the heat-integrated distillation column (HIDiC). A generic, dynamic, first-principle model has been formulated, which is flexible enough to describe various diabatic distillation configurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found and control...

  9. Dynamic Effects of Diabatization in Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2012-01-01

    The dynamic eects of diabatization in distillation columns are investigated in simulation with primary focus on the heat-integrated distillation column (HIDiC). A generic, dynamic, rst-principle model has been formulated, which is exible to describe various diabatic distillation congurations....... Dynamic Relative Gain Array and Singular Value Analysis have been applied in a comparative study of a conventional distillation column and a HIDiC. The study showed increased input-output coupling due to diabatization. Feasible SISO control structures for the HIDiC were also found. Control...

  10. Fringing-field effects in acceleration columns

    International Nuclear Information System (INIS)

    Yavor, M.I.; Weick, H.; Wollnik, H.

    1999-01-01

    Fringing-field effects in acceleration columns are investigated, based on the fringing-field integral method. Transfer matrices at the effective boundaries of the acceleration column are obtained, as well as the general transfer matrix of the region separating two homogeneous electrostatic fields with different field strengths. The accuracy of the fringing-field integral method is investigated

  11. Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography.

    Science.gov (United States)

    Mriziq, Khaled S; Guiochon, Georges

    2008-04-11

    The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC(x), taking place along one side of the bed and the second separation would be a time-based separation, LC(t), as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC(x) x LC(t) instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

  12. Cesium ion exchange using actual waste: Column size considerations

    International Nuclear Information System (INIS)

    Brooks, K.P.

    1996-04-01

    It is presently planned to remove cesium from Hanford tank waste supernates and sludge wash solutions using ion exchange. To support the development of a cesium ion exchange process, laboratory experiments produced column breakthrough curves using wastes simulants in 200 mL columns. To verify the validity of the simulant tests, column runs with actual supernatants are being planned. The purpose of these actual waste tests is two-fold. First, the tests will verify that use of the simulant accurately reflects the equilibrium and rate behavior of the resin compared to actual wastes. Batch tests and column tests will be used to compare equilibrium behaviors and rate behaviors, respectively. Second, the tests will assist in clarifying the negative interactions between the actual waste and the ion exchange resin, which cannot be effectively tested with simulant. Such interactions include organic fouling of the resin and salt precipitation in the column. These effects may affect the shape of the column breakthrough curve. The reduction in column size also may change the shape of the curve, making the individual effects even more difficult to sort out. To simplify the evaluation, the changes due to column size must be either understood or eliminated. This report describes the determination of the column size for actual waste testing that best minimizes the effect of scale-down. This evaluation will provide a theoretical basis for the dimensions of the column. Experimental testing is still required before the final decision can be made. This evaluation will be confined to the study of CS-100 and R-F resins with NCAW simulant and to a limited extent DSSF waste simulant. Only the cesium loading phase has been considered

  13. Stability of embankments over cement deep soil mixing columns

    International Nuclear Information System (INIS)

    Morilla Moar, P.; Melentijevic, S.

    2014-01-01

    The deep soil mixing (DSM) is one of the ground improvement methods used for the construction of embankments over soft soils. DSM column-supported embankments are constructed over soft soils to accelerate its construction, improve embankment stability, increase bearing capacity and control of total and differential settlements. There are two traditional design methods, the Japanese (rigid columns) and the scandinavian (soft and semi-rigid columns). Based on Laboratory analysis and numerical analysis these traditional approaches have been questioned by several authors due to its overestimation of the embankment stability considering that the most common failures types are not assumed. This paper presents a brief review of traditional design methods for embankments on DSM columns constructed in soft soils, studies carried out determine the most likely failure types of DSM columns, methods to decrease the overestimation when using limit equilibrium methods and numerical analysis methods that permit detect appropriate failure modes in DSM columns. Finally a case study was assessed using both limited equilibrium and finite element methods which confirmed the overestimation in the factors of safety on embankment stability over DSM columns. (Author)

  14. Vertebral Column Resection for Rigid Spinal Deformity.

    Science.gov (United States)

    Saifi, Comron; Laratta, Joseph L; Petridis, Petros; Shillingford, Jamal N; Lehman, Ronald A; Lenke, Lawrence G

    2017-05-01

    Broad narrative review. To review the evolution, operative technique, outcomes, and complications associated with posterior vertebral column resection. A literature review of posterior vertebral column resection was performed. The authors' surgical technique is outlined in detail. The authors' experience and the literature regarding vertebral column resection are discussed at length. Treatment of severe, rigid coronal and/or sagittal malalignment with posterior vertebral column resection results in approximately 50-70% correction depending on the type of deformity. Surgical site infection rates range from 2.9% to 9.7%. Transient and permanent neurologic injury rates range from 0% to 13.8% and 0% to 6.3%, respectively. Although there are significant variations in EBL throughout the literature, it can be minimized by utilizing tranexamic acid intraoperatively. The ability to correct a rigid deformity in the spine relies on osteotomies. Each osteotomy is associated with a particular magnitude of correction at a single level. Posterior vertebral column resection is the most powerful posterior osteotomy method providing a successful correction of fixed complex deformities. Despite meticulous surgical technique and precision, this robust osteotomy technique can be associated with significant morbidity even in the most experienced hands.

  15. Interaction diagrams for composite columns exposed to fire

    Directory of Open Access Journals (Sweden)

    Milanović Milivoje

    2014-01-01

    Full Text Available The bearing capacity of the cross section of composite column in fire conditions through changes in the interaction diagram 'bending moment-axialforce' were analyzed in this paper. The M-N interaction diagram presents the relationship between the intensities of the bending moment and the axial force as actions on the column cross section, or the relationship between the design value of the plastic resistance to axial compression of the total cross-section Npl, Rd and the design value of the bending moment resistance Mpl, Rd. It is well known that the temperature increase causes decrease of the load-bearing characteristics of the constitutive materials. This effect directly reflects on the reduction of the axial force and the bending moment that could be accepted by the column cross section. Interaction diagrams for three different types of column cross sections for five different maximal temperatures developed during the fire action were defined. For that purpose the software package SAFIR was used. The columns, materials and load characteristics, as well as all other terms and conditions, were taken in accordance with the relevant Eurocodes and the theory of composite columns.

  16. Recovery of deuterium from H-D gas mixture by thermal diffusion in a multi-concentric-tube column device of fixed total sum of column heights with transverse sampling streams

    International Nuclear Information System (INIS)

    Yeh, H.-M.

    2010-01-01

    The effect of the increment in the number of concentric-tube thermal diffusion columns on the recovery of deuterium from H 2 -HD-D 2 system with fixed total sum of column heights, has been investigated. The equations for predicting the degrees of separation in single-column, double-column and triple-column devices have been derived. Considerable improvement in recovery can be achieved if a multi-column device with larger number of column is employed, instead of a single-column device with column height equal to the same total sum of column heights, especially for the case of higher flow-rate operation and larger total sum of column heights.

  17. Enrichment of heavy water in thermal-diffusion columns connected in series

    International Nuclear Information System (INIS)

    Yeh, Ho-Ming; Chen, Liu Yi

    2009-01-01

    The separation equations for enrichment of heavy water from water isotope mixture by thermal diffusion in multiple columns connected in series, have been derived based on one column design developed in previous work. The improvement in separation is achievable by operating in a double-column device, instead of in a single-column device, with the same total column length. It is also found that further improvement in separation is obtainable if a triple-column device is employed, except for operating under small total column length and low flow rate.

  18. Multi-Column Experimental Test Bed for Xe/Kr Separation

    International Nuclear Information System (INIS)

    Greenhalgh, Mitchell Randy; Garn, Troy Gerry; Welty, Amy Keil; Lyon, Kevin Lawrence; Watson, Tony Leroy

    2015-01-01

    Previous research studies have shown that INL-developed engineered form sorbents are capable of capturing both Kr and Xe from various composite gas streams. The previous experimental test bed provided single column testing for capacity evaluations over a broad temperature range. To advance research capabilities, the employment of an additional column to study selective capture of target species to provide a defined final gas composition for waste storage was warranted. The second column addition also allows for compositional analyses of the final gas product to provide for final storage determinations. The INL krypton capture system was modified by adding an additional adsorption column in order to create a multi-column test bed. The purpose of this modification was to investigate the separation of xenon from krypton supplied as a mixed gas feed. The extra column was placed in a Stirling Ultra-low Temperature Cooler, capable of controlling temperatures between 190 and 253K. Additional piping and valves were incorporated into the system to allow for a variety of flow path configurations. The new column was filled with the AgZ-PAN sorbent which was utilized as the capture medium for xenon while allowing the krypton to pass through. The xenon-free gas stream was then routed to the cryostat filled with the HZ-PAN sorbent to capture the krypton at 191K. Selectivities of xenon over krypton were determined using the new column to verify the system performance and to establish the operating conditions required for multi-column testing. Results of these evaluations verified that the system was operating as designed and also demonstrated that AgZ-PAN exhibits excellent selectivity for xenon over krypton in air at or near room temperature. Two separation tests were performed utilizing a feed gas consisting of 1000 ppmv xenon and 150 ppmv krypton with the balance being made up of air. The AgZ-PAN temperature was held at 295 or 253K while the HZ-PAN was held at 191K for both

  19. Convolutional Codes with Maximum Column Sum Rank for Network Streaming

    OpenAIRE

    Mahmood, Rafid; Badr, Ahmed; Khisti, Ashish

    2015-01-01

    The column Hamming distance of a convolutional code determines the error correction capability when streaming over a class of packet erasure channels. We introduce a metric known as the column sum rank, that parallels column Hamming distance when streaming over a network with link failures. We prove rank analogues of several known column Hamming distance properties and introduce a new family of convolutional codes that maximize the column sum rank up to the code memory. Our construction invol...

  20. Permanent magnet finger-size scanning electron microscope columns

    Energy Technology Data Exchange (ETDEWEB)

    Nelliyan, K., E-mail: elenk@nus.edu.sg [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore)

    2011-07-21

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  1. Permanent magnet finger-size scanning electron microscope columns

    International Nuclear Information System (INIS)

    Nelliyan, K.; Khursheed, A.

    2011-01-01

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  2. Dynamic effects on cyclotron scattering in pulsar accretion columns

    International Nuclear Information System (INIS)

    Brainerd, J.J.; Meszaros, P.

    1991-01-01

    A resonant scattering model for photon reprocessing in a pulsar accretion column is presented. The accretion column is optically thin to Thomson scattering and optically thick to resonant scattering at the cyclotron frequency. Radiation from the neutron star surface propagates freely through the column until the photon energy equals the local cyclotron frequency, at which point the radiation is scattered, much of it back toward the star. The radiation pressure in this regime is insufficient to stop the infall. Some of the scattered radiation heats the stellar surface around the base of the column, which adds a softer component to the spectrum. The partial blocking by the accretion column of X-rays from the surface produces a fan beam emission pattern. X-rays above the surface cyclotron frequency freely escape and are characterized by a pencil beam. Gravitational light bending produces a pencil beam pattern of column-scattered radiation in the antipodal direction, resulting in a strongly angle-dependent cyclotron feature. 31 refs

  3. Aspartic acid incorporated monolithic columns for affinity glycoprotein purification.

    Science.gov (United States)

    Armutcu, Canan; Bereli, Nilay; Bayram, Engin; Uzun, Lokman; Say, Rıdvan; Denizli, Adil

    2014-02-01

    Novel aspartic acid incorporated monolithic columns were prepared to efficiently affinity purify immunoglobulin G (IgG) from human plasma. The monolithic columns were synthesised in a stainless steel HPLC column (20 cm × 5 mm id) by in situ bulk polymerisation of N-methacryloyl-L-aspartic acid (MAAsp), a polymerisable derivative of L-aspartic acid, and 2-hydroxyethyl methacrylate (HEMA). Monolithic columns [poly(2-hydroxyethyl methacrylate-N-methacryloyl-L-aspartic acid) (PHEMAsp)] were characterised by swelling studies, Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The monolithic columns were used for IgG adsorption/desorption from aqueous solutions and human plasma. The IgG adsorption depended on the buffer type, and the maximum IgG adsorption from aqueous solution in phosphate buffer was 0.085 mg/g at pH 6.0. The monolithic columns allowed for one-step IgG purification with a negligible capacity decrease after ten adsorption-desorption cycles. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Hydrogen peroxide stabilization in one-dimensional flow columns

    Science.gov (United States)

    Schmidt, Jeremy T.; Ahmad, Mushtaque; Teel, Amy L.; Watts, Richard J.

    2011-09-01

    Rapid hydrogen peroxide decomposition is the primary limitation of catalyzed H 2O 2 propagations in situ chemical oxidation (CHP ISCO) remediation of the subsurface. Two stabilizers of hydrogen peroxide, citrate and phytate, were investigated for their effectiveness in one-dimensional columns of iron oxide-coated and manganese oxide-coated sand. Hydrogen peroxide (5%) with and without 25 mM citrate or phytate was applied to the columns and samples were collected at 8 ports spaced 13 cm apart. Citrate was not an effective stabilizer for hydrogen peroxide in iron-coated sand; however, phytate was highly effective, increasing hydrogen peroxide residuals two orders of magnitude over unstabilized hydrogen peroxide. Both citrate and phytate were effective stabilizers for manganese-coated sand, increasing hydrogen peroxide residuals by four-fold over unstabilized hydrogen peroxide. Phytate and citrate did not degrade and were not retarded in the sand columns; furthermore, the addition of the stabilizers increased column flow rates relative to unstabilized columns. These results demonstrate that citrate and phytate are effective stabilizers of hydrogen peroxide under the dynamic conditions of one-dimensional columns, and suggest that citrate and phytate can be added to hydrogen peroxide before injection to the subsurface as an effective means for increasing the radius of influence of CHP ISCO.

  5. Mathematical modeling of alcohol distillation columns

    Directory of Open Access Journals (Sweden)

    Ones Osney Pérez

    2011-04-01

    Full Text Available New evaluation modules are proposed to extend the scope of a modular simulator oriented to the sugar cane industry, called STA 4.0, in a way that it can be used to carry out x calculation and analysis in ethanol distilleries. Calculation modules were developed for the simulation of the columns that are combined in the distillation area. Mathematical models were supported on materials and energy balances, equilibrium relations and thermodynamic properties of the ethanol-water system. Ponchon-Savarit method was used for the evaluation of the theoretical stages in the columns. A comparison between the results using Ponchon- Savarit method and those obtained applying McCabe-Thiele method was done for a distillation column. These calculation modules for ethanol distilleries were applied to a real case for validation.

  6. Hollow-Core FRP–Concrete–Steel Bridge Columns under Torsional Loading

    Directory of Open Access Journals (Sweden)

    Sujith Anumolu

    2017-11-01

    Full Text Available This paper presents the behavior of hollow-core fiber-reinforced polymer–concrete–steel (HC-FCS columns under cyclic torsional loading combined with constant axial load. The HC-FCS consists of an outer fiber-reinforced polymer (FRP tube and an inner steel tube, with a concrete shell sandwiched between the two tubes. The FRP tube was stopped at the surface of the footing, and provided confinement to the concrete shell from the outer direction. The steel tube was embedded into the footing to a length of 1.8 times the diameter of the steel tube. The longitudinal and transversal reinforcements of the column were provided by the steel tube only. A large-scale HC-FCS column with a diameter of 24 in. (610 mm and applied load height of 96 in. (2438 mm with an aspect ratio of four was investigated during this study. The study revealed that the torsional behavior of the HC-FCS column mainly depended on the stiffness of the steel tube and the interactions among the column components (concrete shell, steel tube, and FRP tube. A brief comparison of torsional behavior was made between the conventional reinforced concrete columns and the HC-FCS column. The comparison illustrated that both column types showed high initial stiffness under torsional loading. However, the HC-FCS column maintained the torsion strength until a high twist angle, while the conventional reinforced concrete column did not.

  7. The general packed column : an analytical solution

    NARCIS (Netherlands)

    Gielen, J.L.W.

    2000-01-01

    The transient behaviour of a packed column is considered. The column, uniformly packed on a macroscopic scale, is multi-structured on the microscopic level: the solid phase consists of particles, which may differ in incidence, shape or size, and other relevant physical properties. Transport in the

  8. Revised Thermal Analysis of LANL Ion Exchange Column

    Energy Technology Data Exchange (ETDEWEB)

    Laurinat, J

    2006-04-11

    This document updates a previous calculation of the temperature distributions in a Los Alamos National Laboratory (LANL) ion exchange column.1 LANL operates two laboratory-scale anion exchange columns, in series, to extract Pu-238 from nitric acid solutions. The Defense Nuclear Facilities Safety Board has requested an updated analysis to calculate maximum temperatures for higher resin loading capacities obtained with a new formulation of the Reillex HPQ anion exchange resin. The increased resin loading capacity will not exceed 118 g plutonium per L of resin bed. Calculations were requested for normal operation of the resin bed at the minimum allowable solution feed rate of 30 mL/min and after an interruption of flow at the end of the feed stage, when one of the columns is fully loaded. The object of the analysis is to demonstrate that the decay heat from the Pu-238 will not cause resin bed temperatures to increase to a level where the resin significantly degrades. At low temperatures, resin bed temperatures increase primarily due to decay heat. At {approx}70 C a Low Temperature Exotherm (LTE) resulting from the reaction between 8-12 M HNO{sub 3} and the resin has been observed. The LTE has been attributed to an irreversible oxidation of pendant ethyl benzene groups at the termini of the resin polymer chains by nitric acid. The ethyl benzene groups are converted to benzoic acid moities. The resin can be treated to permanently remove the LTE by heating a resin suspension in 8M HNO{sub 3} for 30-45 minutes. No degradation of the resin performance is observed after the LTE removal treatment. In fact, heating the resin in boiling ({approx}115-120 C) 12 M HNO{sub 3} for 3 hr displays thermal stability analogous to resin that has been treated to remove the LTE. The analysis is based on a previous study of the SRS Frames Waste Recovery (FWR) column, performed in support of the Pu-238 production campaign for NASA's Cassini mission. In that study, temperature transients

  9. Dopamine-imprinted monolithic column for capillary electrochromatography.

    Science.gov (United States)

    Aşır, Süleyman; Sarı, Duygu; Derazshamshir, Ali; Yılmaz, Fatma; Şarkaya, Koray; Denizli, Adil

    2017-11-01

    A dopamine-imprinted monolithic column was prepared and used in capillary electrochromatography as stationary phase for the first time. Dopamine was selectively separated from aqueous solution containing the competitor molecule norepinephrine, which is similar in size and shape to the template molecule. Morphology of the dopamine-imprinted column was observed by scanning electron microscopy. The influence of the organic solvent content of mobile phase, applied pressure and pH of the mobile phase on the recognition of dopamine by the imprinted monolithic column has been evaluated, and the imprinting effect in the dopamine-imprinted monolithic polymer was verified. Developed dopamine-imprinted monolithic column resulted in excellent separation of dopamine from structurally related competitor molecule, norepinephrine. Separation was achieved in a short period of 10 min, with the electrophoretic mobility of 5.81 × 10 -5  m 2 V -1 s -1 at pH 5.0 and 500 mbar pressure. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. column frame for design of reinforced concrete sway frames

    African Journals Online (AJOL)

    adminstrator

    design of slender reinforced concrete columns in sway frames according .... concrete,. Ac = gross cross-sectional area of the columns. Step 3: Effective Buckling Length Factors. The effective buckling length factors of columns in a sway frame shall be computed by .... shall have adequate resistance to failure in a sway mode ...

  11. Dynamics and Control of Distillation Columns - A Critical Survey

    Directory of Open Access Journals (Sweden)

    Sigurd Skogestad

    1997-07-01

    Full Text Available Distillation column dynamics and control have been viewed by many as a very mature or even dead field. However, as is discussed in this paper significant new results have appeared over the last 5-10 years. These results include multiple steady states and instability in simple columns with ideal thermodynamics (which was believed to be impossible, the understanding of the difference between various control configurations and the systematic transformation between these, the feasibility of using the distillate-bottom structure, for control (which was believed to be impossible, the importance of flow dynamics for control studies, the fundamental problems in identifying models from open-loops responses, the use of simple regression estimators to estimate composition from temperatures, and an improved general understanding of the dynamic behavior of distillation columns which includes a better understanding of the fundamental difference between internal and external flow, simple formulas for estimating the dominant time constant, and a derivation of the linearizing effect of logarithmic transformations. These issues apply to all columns, even for ideal mixtures and simple columns with only two products. In addition, there have been significant advances for cases with complex thermodynamics and complex column configurations. These include the behavior and control of azeotropic distillation columns, and the possible complex dynamics of nonideal mixtures and of interlinked columns. However, both for the simple and more complex cases there are still a number of areas where further research is needed.

  12. Short-pulse optical parametric chirped-pulse amplification for the generation of high-power few-cycle pulses

    International Nuclear Information System (INIS)

    Major, Zs.; Osterhoff, J.; Hoerlein, R.; Karsch, S.; Fuoloep, J.A.; Krausz, F.; Ludwig-Maximilians Universitaet, Muenchen

    2006-01-01

    Complete test of publication follows. In the quest for a way to generate ultrashort, high-power, few-cycle laser pulses the discovery of optical parametric amplification (OPA) has opened up to the path towards a completely new regime, well beyond that of conventional laser amplification technology. The main advantage of this parametric amplification process is that it allows for an extremely broad amplification bandwidth compared to any known laser amplifier medium. When combined with the chirped-pulse amplification (CPA) principle (i.e. OPCPA), on one hand pulses of just 10 fs duration and 8 mJ pulse energy have been demonstrated. On the other hand, pulse energies of up to 30 J were also achieved on a different OPCPA system; the pulse duration in this case, however, was 100 fs. In order to combine ultrashort pulse durations (i.e. pulses in the few-cycle regime) with high pulse energies (i.e. in the Joule range) we propose tu pump on OPCPA chain with TW-scale short pulses (100 fs - 1 ps instead of > 100 ps of previous OPCPA systems) delivered by a conventional CPA system. This approach inherently improves the conditions for generating high-power ultrashort pulses using OPCPA in the following ways. Firstly, the short pump pulse duration reduces the necessary stretching factor for the seed pulse, thereby increasing stretching and compression fidelity. Secondly, also due to the shortened pump pulse duration, a much higher contrast is achieved. Finally, the significantly increased pump power makes the use of thinner OPCPA crystals possible, which implies an even broader amplification bandwidth, thereby allowing for even shorter pulses. We carried out theoretical investigations to show the feasibility of such a set-up. Alongside these studies we will also present preliminary experimental results of an OPCPA system pumped by the output of our Ti:Sapphire ATLAS laser, currently delivering 350 mJ in 43 fs. An insight into the planned scaling of this technique to petawatt

  13. Slender CRC Columns

    DEFF Research Database (Denmark)

    Aarup, Bendt; Jensen, Lars Rom; Ellegaard, Peter

    2005-01-01

    CRC is a high-performance steel fibre reinforced concrete with a typical compressive strength of 150 MPa. Design methods for a number of structural elements have been developed since CRC was invented in 1986, but the current project set out to further investigate the range of columns for which...

  14. Performance of zeolite scavenge column in Xe monitoring system

    International Nuclear Information System (INIS)

    Wang Qian; Wang Hongxia; Li Wei; Bian Zhishang

    2010-01-01

    In order to improve the performance of zeolite scavenge column, its ability of removal of humidity and carbon dioxide was studied by both static and dynamic approaches. The experimental results show that various factors, including the column length and diameter, the mass of zeolite, the content of water in air, the temperature rise during adsorption, and the activation effectiveness all effect the performance of zeolite column in scavenging humanity and carbon dioxide. Based on these results and previous experience, an optimized design of the zeolite column is made for use in xenon monitoring system. (authors)

  15. Pulsed electron beam generation with fast repetitive double pulse system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Surender Kumar; Deb, Pankaj; Shyam, Anurag, E-mail: surender80@gmail.com [Energetics and Electromagnetics Division, Bhabha Atomic Research Centre, Visakhapatnam (India); Sharma, Archana [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

  16. Behaviour of normal reinforced concrete columns exposed to different soils

    Directory of Open Access Journals (Sweden)

    Rasheed Laith

    2018-01-01

    Full Text Available Concrete resistance to sulfate attack is one of the most important characteristics for maintaining the durability of concrete. In this study, the effect of the attack of sulfate salts on normal reinforced concrete column was investigated by burying these columns in two types of soils (sandy and clayey in two pits at a depth of 3 m in one of the agricultural areas in the holy city of Karbala, one containing sandy soil (SO3 = 10.609% and the other containing clayey soil with (SO3 = 2.61%. The tests were used (pure axial compression test of reinforced concrete columns, compressive strength test, and splitting tensile strength test, absorption, voids ratio and finally density. It`s found that the strength of RC columns decreasing by (12.51% for age (240 days, for columns buried in clayey soil, where the strength increased by (11.71% for the same period, for columns buried in sandy soils, with respect to the reference column.

  17. Column studies on BTEX biodegradation under microaerophilic and denitrifying conditions

    International Nuclear Information System (INIS)

    Hutchins, S.R.; Moolenaar, S.W.; Rhodes, D.E.

    1992-01-01

    Two column tests were conducted using aquifer material to simulate the nitrate field demonstration project carried out earlier at Traverse City, Michigan. The objectives were to better define the effect nitrate addition had on biodegradation of benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes (BTEX) in the field study, and to determine whether BTEX removal can be enhanced by supplying a limited amount of oxygen as a supplemental electron acceptor. Columns were operated using limited oxygen, limited oxygen plus nitrate, and nitrate alone. In the first column study, benzene was generally recalcitrant compared to the alkylbenzenes (TEX), although some removal did occur. In the second column study, nitrate was deleted from the feed to the column originally receiving nitrate alone and added to the feed of the column originally receiving limited oxygen alone. Although the requirement for nitrate for optimum TEX removal was clearly demonstrated in these columns, there were significant contributions by biotic and abiotic processes other than denitrification which could not be quantified

  18. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...

  19. 2-Micron Triple-Pulse Integrated Path Differential Absorption Lidar Development for Simultaneous Airborne Column Measurements of Carbon Dioxide and Water Vapor in the Atmosphere

    Science.gov (United States)

    Singh, Upendra N.; Petros, Mulugeta; Refaat, Tamer F.; Yu, Jirong

    2016-01-01

    For more than 15 years, NASA Langley Research Center (LaRC) has contributed in developing several 2-micron carbon dioxide active remote sensors using the DIAL technique. Currently, an airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar is under development at NASA LaRC. This paper focuses on the advancement of the 2-micron triple-pulse IPDA lidar development. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of wavelength control, packaging and lidar integration. In addition, receiver development updates will also be presented, including telescope integration, detection systems and data acquisition electronics. Future plan for IPDA lidar system for ground integration, testing and flight validation will be presented.

  20. Strength degradation of oxidized graphite support column in VHTR

    International Nuclear Information System (INIS)

    Park, Byung Ha; No, Hee Cheon

    2010-01-01

    Air-ingress events caused by large pipe breaks are important accidents considered in the design of Very High Temperature Gas-Cooled Reactors (VHTRs). A main safety concern for this type of event is the possibility of core collapse following the failure of the graphite support column, which can be oxidized by ingressed air. In this study, the main target is to predict the strength of the oxidized graphite support column. Through compression tests for fresh and oxidized graphite columns, the compressive strength of IG-110 was obtained. The buckling strength of the IG-110 column is expressed using the following empirical straight-line formula: σ cr,buckling =91.34-1.01(L/r). Graphite oxidation in Zone 1 is volume reaction and that in Zone 3 is surface reaction. We notice that the ultimate strength of the graphite column oxidized in Zones 1 and 3 only depends on the slenderness ratio and bulk density. Its strength degradation oxidized in Zone 1 is expressed in the following nondimensional form: σ/σ 0 =exp(-kd), k=0.114. We found that the strength degradation of a graphite column, oxidized in Zone 3, follows the above buckling empirical formula as the slenderness of the column changes. (author)

  1. Investigation of Gas Holdup in a Vibrating Bubble Column

    Science.gov (United States)

    Mohagheghian, Shahrouz; Elbing, Brian

    2015-11-01

    Synthetic fuels are part of the solution to the world's energy crisis and climate change. Liquefaction of coal during the Fischer-Tropsch process in a bubble column reactor (BCR) is a key step in production of synthetic fuel. It is known from the 1960's that vibration improves mass transfer in bubble column. The current study experimentally investigates the effect that vibration frequency and amplitude has on gas holdup and bubble size distribution within a bubble column. Air (disperse phase) was injected into water (continuous phase) through a needle shape injector near the bottom of the column, which was open to atmospheric pressure. The air volumetric flow rate was measured with a variable area flow meter. Vibrations were generated with a custom-made shaker table, which oscillated the entire column with independently specified amplitude and frequency (0-30 Hz). Geometric dependencies can be investigated with four cast acrylic columns with aspect ratios ranging from 4.36 to 24, and injector needle internal diameters between 0.32 and 1.59 mm. The gas holdup within the column was measured with a flow visualization system, and a PIV system was used to measure phase velocities. Preliminary results for the non-vibrating and vibrating cases will be presented.

  2. Multi-column adsorption systems with condenser for tritiated water vapor removal

    International Nuclear Information System (INIS)

    Kotoh, Kenji; Kudo, Kazuhiko

    1996-01-01

    Two types of multi-column adsorption system are proposed as the system for removal of tritiated moisture from tritium process gases or/and handling room atmospheres. The types are of recycle use of adsorption columns, and are composed of twin or triplet columns and one condenser which is used for collecting the adsorbed moisture from columns in desorption process. The systems utilize the dry gas from a working column as the purge gas for regenerating a saturated column and appropriate an active column for recovery of the tritiated moisture passing through the condenser. Each column hence needs the additional amount of adsorbent for collecting the moisture from the condenser. In the modeling and design of an adsorption column, it is primary to estimate the necessary amount of a candidate adsorbent for its packed-bed. The performance of the proposed systems is examined here by analyzing the dependence of the necessary amount of adsorbent for their columns on process operational conditions and adsorbent moisture-adsorption characteristics. The result shows that the necessary amount is sensitive to the types of adsorption isotherm, and suggests that these systems should employ adsorbents which exhibit the Langmuir-type isotherms. (author)

  3. Seismic Performance of High-Ductile Fiber-Reinforced Concrete Short Columns

    Directory of Open Access Journals (Sweden)

    Mingke Deng

    2018-01-01

    Full Text Available This study mainly aims to investigate the effectiveness of high-ductile fiber-reinforced concrete (HDC as a means to enhance the seismic performance of short columns. Six HDC short columns and one reinforced concrete (RC short column were designed and tested under lateral cyclic loading. The influence of the material type (concrete or HDC, axial load, stirrup ratio, and shear span ratio on crack patterns, hysteresis behavior, shear strength, deformation capacity, energy dissipation, and stiffness degradation was presented and discussed, respectively. The test results show that the RC short column failed in brittle shear with poor energy dissipation, while using HDC to replace concrete can effectively improve the seismic behavior of the short columns. Compared with the RC short column, the shear strength of HDC specimens was improved by 12.6–30.2%, and the drift ratio and the energy dissipation increases were 56.9–88.5% and 237.7–336.7%, respectively, at the ultimate displacement. Additionally, the prediction model of the shear strength for RC columns based on GB50010-2010 (Chinese code can be safely adopted to evaluate the shear strength of HDC short columns.

  4. Pulse Distortion in Saturated Fiber Optical Parametric Chirped Pulse Amplification

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Da Ros, Francesco; Rottwitt, Karsten

    2012-01-01

    Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation.......Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation....

  5. Insights into Tikhonov regularization: application to trace gas column retrieval and the efficient calculation of total column averaging kernels

    Directory of Open Access Journals (Sweden)

    T. Borsdorff

    2014-02-01

    Full Text Available Insights are given into Tikhonov regularization and its application to the retrieval of vertical column densities of atmospheric trace gases from remote sensing measurements. The study builds upon the equivalence of the least-squares profile-scaling approach and Tikhonov regularization method of the first kind with an infinite regularization strength. Here, the vertical profile is expressed relative to a reference profile. On the basis of this, we propose a new algorithm as an extension of the least-squares profile scaling which permits the calculation of total column averaging kernels on arbitrary vertical grids using an analytic expression. Moreover, we discuss the effective null space of the retrieval, which comprises those parts of a vertical trace gas distribution which cannot be inferred from the measurements. Numerically the algorithm can be implemented in a robust and efficient manner. In particular for operational data processing with challenging demands on processing time, the proposed inversion method in combination with highly efficient forward models is an asset. For demonstration purposes, we apply the algorithm to CO column retrieval from simulated measurements in the 2.3 μm spectral region and to O3 column retrieval from the UV. These represent ideal measurements of a series of spaceborne spectrometers such as SCIAMACHY, TROPOMI, GOME, and GOME-2. For both spectral ranges, we consider clear-sky and cloudy scenes where clouds are modelled as an elevated Lambertian surface. Here, the smoothing error for the clear-sky and cloudy atmosphere is significant and reaches several percent, depending on the reference profile which is used for scaling. This underlines the importance of the column averaging kernel for a proper interpretation of retrieved column densities. Furthermore, we show that the smoothing due to regularization can be underestimated by calculating the column averaging kernel on a too coarse vertical grid. For both

  6. Materials performance in prototype Thermal Cycling Absorption Process (TCAP) columns

    International Nuclear Information System (INIS)

    Clark, E.A.

    1992-01-01

    Two prototype Thermal Cycling Absorption Process (TCAP) columns have been metallurgically examined after retirement, to determine the causes of failure and to evaluate the performance of the column container materials in this application. Leaking of the fluid heating and cooling subsystems caused retirement of both TCAP columns, not leaking of the main hydrogen-containing column. The aluminum block design TCAP column (AHL block TCAP) used in the Advanced Hydride Laboratory, Building 773-A, failed in one nitrogen inlet tube that was crimped during fabrication, which lead to fatigue crack growth in the tube and subsequent leaking of nitrogen from this tube. The Third Generation stainless steel design TCAP column (Third generation TCAP), operated in 773-A room C-061, failed in a braze joint between the freon heating and cooling tubes (made of copper) and the main stainless steel column. In both cases, stresses from thermal cycling and local constraint likely caused the nucleation and growth of fatigue cracks. No materials compatibility problems between palladium coated kieselguhr (the material contained in the TCAP column) and either aluminum or stainless steel column materials were observed. The aluminum-stainless steel transition junction appeared to be unaffected by service in the AHL block TCAP. Also, no evidence of cracking was observed in the AHL block TCAP in a location expected to experience the highest thermal shock fatigue in this design. It is important to limit thermal stresses caused by constraint in hydride systems designed to work by temperature variation, such as hydride storage beds and TCAP columns

  7. A Novel Triple-Pulsed 2-micrometer Lidar for Simultaneous and Independent CO2 and H2O Column Measurement

    Science.gov (United States)

    Yu, Jirong; Singh, Upendra; Petros, Mulugeta; Refaat, Tamer

    2015-01-01

    The study of global warming needs precisely and accurately measuring greenhouse gases concentrations in the atmosphere. CO2 and H2O are important greenhouse gases that significantly contribute to the carbon cycle and global radiation budget on Earth. NRC Decadal Survey recommends a mission for Active Sensing of Carbon Dioxide (CO2) over Nights, Days and Seasons (ASCENDS). 2 micron laser is a viable IPDA transmitter to measure CO2 and H2O column density from space. The objective is to demonstrate a first airborne direct detection 2 micron IPDA lidar for CO2 and H2O measurements.

  8. Columns in Clay

    Science.gov (United States)

    Leenhouts, Robin

    2010-01-01

    This article describes a clay project for students studying Greece and Rome. It provides a wonderful way to learn slab construction techniques by making small clay column capitols. With this lesson, students learn architectural vocabulary and history, understand the importance of classical architectural forms and their influence on today's…

  9. 46 CFR 174.085 - Flooding on column stabilized units.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Flooding on column stabilized units. 174.085 Section 174... Units § 174.085 Flooding on column stabilized units. (a) Watertight compartments that are outboard of... of the unit, must be assumed to be subject to flooding as follows: (1) When a column is subdivided...

  10. Modeling and analysis of conventional and heat-integrated distillation columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2015-01-01

    A generic model that can cover diabatic and adiabatic distillation column configurations is presented, with the aim ofproviding a consistent basis for comparison of alternative distillation column technologies. Both a static and a dynamic formulation of the model, together with a model catalogue...... consisting of the conventional, the heat-integrated and the mechanical vapor recompression distillation columns are presented. The solution procedure of the model is outlined and illustrated in three case studies. One case study being a benchmark study demonstrating the size of the model and the static...... properties of two different heat-integrated distillation column (HIDiC) schemes and the mechanical vapor recompression column. The second case study exemplifies the difference between a HIDiC and a conventional distillation column in the composition profiles within a multicomponent separation, whereas...

  11. Synthesis and characterization of Mn-doped ZnO column arrays

    International Nuclear Information System (INIS)

    Yang Mei; Guo Zhixing; Qiu Kehui; Long Jianping; Yin Guangfu; Guan Denggao; Liu Sutian; Zhou Shijie

    2010-01-01

    Mn-doped ZnO column arrays were successfully synthesized by conventional sol-gel process. Effect of Mn/Zn atomic ratio and reaction time were investigated, and the morphology, tropism and optical properties of Mn-doped ZnO column arrays were characterized by SEM, XRD and photoluminescence (PL) spectroscopy. The result shows that a Mn/Zn atomic ratio of 0.1 and growth time of 12 h are the optimal condition for the preparation of densely distributed ZnO column arrays. XRD analysis shows that Mn-doped ZnO column arrays are highly c-axis oriented. As for Mn-doped ZnO column arrays, obvious increase of photoluminescence intensity is observed at the wavelength of ∼395 nm and ∼413 nm, compared to pure ZnO column arrays.

  12. Updating the induction module from single-pulse to double-pulses

    International Nuclear Information System (INIS)

    Huang Ziping; Wang Huacen; Deng Jianjun

    2002-01-01

    A double-pulse Linear Induced Accelerator (LIA) module is reconstructed based on a usual simple-pulse LIA module. By changing the length of one of the cables between the inductive cell and the Blumlein pulse forming line, two induction pulses with 90 ns FWHM and 150 kV pulse voltage are generated by the ferrite cores inductive cell. The interval time of the pulses is adjustable by changing the lengths of the cable

  13. Evaluation of bipolar pulse generator for high-purity pulsed ion beam

    International Nuclear Information System (INIS)

    Ito, H.; Kitamura, I.; Masugata, K.

    2008-01-01

    A new type of pulsed ion beam accelerator named 'bipolar pulse accelerator (BPA)' has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the experimental results of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PEL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time. At present the bipolar pulse generator is installed in the B y type magnetically insulated ion diode and we carry out the experiment on the production of an intense pulsed ion beam by the bipolar pulse accelerator. (author)

  14. The Micro-Pulse Lidar Network (MPLNET): A Federated Network of Micro-pulse Lidars and AERONET Sunphotometers

    Science.gov (United States)

    Welton, Ellsworth J.; Campbell, James R.; Spinhirne, James D.; Berkoff, Timothy A.; Holben, Brent; Tsay, Si-Chee

    2004-01-01

    We present the formation of a new global-ground based eye-safe lidar network, the NASA Micro-Pulse Lidar Network (MPLNET). The aim of MPLNET is to acquire long- term observations of aerosol and cloud vertical profiles at unique geographic sites within the NASA Aerosol Robotic Network (AERONET). MPLNET utilizes standard instrumentation and data processing algorithms for efficient network operations and direct comparison of data between each site. The micro-pulse lidar is eye-safe, compact, and commercially available, and most easily allows growth of the network without sacrificing standardized instrumentation goals. Network growth follows a federated approach, pioneered by AERONET, wherein independent research groups may join MPLNET with their own instrument and site. MPLNET sites produce not only vertical profile data, but also column-averaged products already available from AERONET (aerosol optical depth, sky radiance, size distributions). Algorithms are presented for each MPLNET data product. Real-time Level 1 data products (next-day) include daily lidar signal images from the surface to -2Okm, and Level 1.5 aerosol extinction profiles at times co-incident with AERONET observations. Quality assured Level 2 aerosol extinction profiles are generated after screening the Level 1.5 results and removing bad data. Level 3 products include continuous day/night aerosol extinction profiles, and are produced using Level 2 calibration data. Rigorous uncertainty calculations are presented for all data products. Analysis of MPLNET data show the MPL and our analysis routines are capable of successfully retrieving aerosol profiles, with the strenuous accounting of uncertainty necessary for accurate interpretation of the results.

  15. Mini-columns for Conducting Breakthrough Experiments. Design and Construction

    Energy Technology Data Exchange (ETDEWEB)

    Dittrich, Timothy M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ware, Stuart Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-06-11

    Experiments with moderately and strongly sorbing radionuclides (i.e., U, Cs, Am) have shown that sorption between experimental solutions and traditional column materials must be accounted for to accurately determine stationary phase or porous media sorption properties (i.e., sorption site density, sorption site reaction rate coefficients, and partition coefficients or Kd values). This report details the materials and construction of mini-columns for use in breakthrough columns to allow for accurate measurement and modeling of sorption parameters. Material selection, construction techniques, wet packing of columns, tubing connections, and lessons learned are addressed.

  16. Self-consistent model for pulsed direct-current N2 glow discharge

    International Nuclear Information System (INIS)

    Liu Chengsen

    2005-01-01

    A self-consistent analysis of a pulsed direct-current (DC) N 2 glow discharge is presented. The model is based on a numerical solution of the continuity equations for electron and ions coupled with Poisson's equation. The spatial-temporal variations of ionic and electronic densities and electric field are obtained. The electric field structure exhibits all the characteristic regions of a typical glow discharge (the cathode fall, the negative glow, and the positive column). Current-voltage characteristics of the discharge can be obtained from the model. The calculated current-voltage results using a constant secondary electron emission coefficient for the gas pressure 133.32 Pa are in reasonable agreement with experiment. (authors)

  17. On-column reduction of catecholamine quinones in stainless steel columns during liquid chromatography.

    Science.gov (United States)

    Xu, R; Huang, X; Kramer, K J; Hawley, M D

    1995-10-10

    The chromatographic behavior of quinones derived from the oxidation of dopamine and N-acetyldopamine has been studied using liquid chromatography (LC) with both a diode array detector and an electrochemical detector that has parallel dual working electrodes. When stainless steel columns are used, an anodic peak for the oxidation of the catecholamine is observed at the same retention time as a cathodic peak for the reduction of the catecholamine quinone. In addition, the anodic peak exhibits a tail that extends to a second anodic peak for the catecholamine. The latter peak occurs at the normal retention time of the catecholamine. The origin of this phenomenon has been studied and metallic iron in the stainless steel components of the LC system has been found to reduce the quinones to their corresponding catecholamines. The simultaneous appearance of a cathodic peak for the reduction of catecholamine quinone and an anodic peak for the oxidation of the corresponding catecholamine occurs when metallic iron in the exit frit reduces some of the quinones as the latter exits the column. This phenomenon is designated as the "concurrent anodic-cathodic response." It is also observed for quinones of of 3,4-dihydroxybenzoic acid and probably occurs with o- or p-quinones of other dihydroxyphenyl compounds. The use of nonferrous components in LC systems is recommended to eliminate possible on-column reduction of quinones.

  18. Reliability assessment of slender concrete columns at the stability failure

    Science.gov (United States)

    Valašík, Adrián; Benko, Vladimír; Strauss, Alfred; Täubling, Benjamin

    2018-01-01

    The European Standard for designing concrete columns within the use of non-linear methods shows deficiencies in terms of global reliability, in case that the concrete columns fail by the loss of stability. The buckling failure is a brittle failure which occurs without warning and the probability of its formation depends on the columns slenderness. Experiments with slender concrete columns were carried out in cooperation with STRABAG Bratislava LTD in Central Laboratory of Faculty of Civil Engineering SUT in Bratislava. The following article aims to compare the global reliability of slender concrete columns with slenderness of 90 and higher. The columns were designed according to methods offered by EN 1992-1-1 [1]. The mentioned experiments were used as basis for deterministic nonlinear modelling of the columns and subsequent the probabilistic evaluation of structural response variability. Final results may be utilized as thresholds for loading of produced structural elements and they aim to present probabilistic design as less conservative compared to classic partial safety factor based design and alternative ECOV method.

  19. Effects of Irregular Bridge Columns and Feasibility of Seismic Regularity

    Science.gov (United States)

    Thomas, Abey E.

    2018-05-01

    Bridges with unequal column height is one of the main irregularities in bridge design particularly while negotiating steep valleys, making the bridges vulnerable to seismic action. The desirable behaviour of bridge columns towards seismic loading is that, they should perform in a regular fashion, i.e. the capacity of each column should be utilized evenly. But, this type of behaviour is often missing when the column heights are unequal along the length of the bridge, allowing short columns to bear the maximum lateral load. In the present study, the effects of unequal column height on the global seismic performance of bridges are studied using pushover analysis. Codes such as CalTrans (Engineering service center, earthquake engineering branch, 2013) and EC-8 (EN 1998-2: design of structures for earthquake resistance. Part 2: bridges, European Committee for Standardization, Brussels, 2005) suggests seismic regularity criterion for achieving regular seismic performance level at all the bridge columns. The feasibility of adopting these seismic regularity criterions along with those mentioned in literatures will be assessed for bridges designed as per the Indian Standards in the present study.

  20. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  1. Prediction of axial limit capacity of stone columns using dimensional analysis

    Science.gov (United States)

    Nazaruddin A., T.; Mohamed, Zainab; Mohd Azizul, L.; Hafez M., A.

    2017-08-01

    Stone column is the most favorable method used by engineers in designing work for stabilization of soft ground for road embankment, and foundation for liquid structure. Easy installation and cheaper cost are among the factors that make stone column more preferable than other method. Furthermore, stone column also can acts as vertical drain to increase the rate of consolidation during preloading stage before construction work started. According to previous studied there are several parameters that influence the capacity of stone column. Among of them are angle friction of among the stones, arrangement of column (two pattern arrangement most applied triangular and square), spacing center to center between columns, shear strength of soil, and physical size of column (diameter and length). Dimensional analysis method (Buckingham-Pi Theorem) has used to carry out the new formula for prediction of load capacity stone columns. Experimental data from two previous studies was used for analysis of study.

  2. Wire-Mesh Tomography Measurements of Void Fraction in Rectangular Bubble Columns

    International Nuclear Information System (INIS)

    Reddy Vanga, B.N.; Lopez de Bertodano, M.A.; Zaruba, A.; Prasser, H.M.; Krepper, E.

    2004-01-01

    Bubble Columns are widely used in the process industry and their scale-up from laboratory scale units to industrial units have been a subject of extensive study. The void fraction distribution in the bubble column is affected by the column size, superficial velocity of the dispersed phase, height of the liquid column, size of the gas bubbles, flow regime, sparger design and geometry of the bubble column. The void fraction distribution in turn affects the interfacial momentum transfer in the bubble column. The void fraction distribution in a rectangular bubble column 10 cm wide and 2 cm deep has been measured using Wire-Mesh Tomography. Experiments were performed in an air-water system with the column operating in the dispersed bubbly flow regime. The experiments also serve the purpose of studying the performance of wire-mesh sensors in batch flows. A 'wall peak' has been observed in the measured void fraction profiles, for the higher gas flow rates. This 'wall peak' seems to be unique, as this distribution has not been previously reported in bubble column literature. Low gas flow rates yielded the conventional 'center peak' void profile. The effect of column height and superficial gas velocity on the void distribution has been investigated. Wire-mesh Tomography also facilitates the measurement of bubble size distribution in the column. This paper presents the measurement principle and the experimental results for a wide range of superficial gas velocities. (authors)

  3. Pulse-shaping strategies in short-pulse fiber amplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Schimpf, Damian Nikolaus

    2010-02-09

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  4. Pulse-shaping strategies in short-pulse fiber amplifiers

    International Nuclear Information System (INIS)

    Schimpf, Damian Nikolaus

    2010-01-01

    Ultrashort pulse lasers are an important tool in scientific and industrial applications. However, many applications are demanding higher average powers from these ultrashort pulse sources. This can be achieved by combining direct diode pumping with novel gain media designs. In particular, ultrashort pulse fiber lasers are now delivering average powers in the kW range. However, the design of fiber lasers, producing pulses with high peak-powers, is challenging due to the impact of nonlinear effects. To significantly reduce these detrimental effects in ultrashort pulse fiber amplifers, the combination of chirped pulse amplification (CPA) and large mode area fibers is employed. Using these methods, the pulse energy of fiber lasers has been steadily increasing for the past few years. Recently, a fiber-based CPA-system has been demonstrated which produces pulse energies of around 1 mJ. However, both the stretching and the enlargement of the mode area are limited, and therefore, the impact of nonlinearity is still noticed in systems employing such devices. The aim of this thesis is the analysis of CPA-systems operated beyond the conventional nonlinear limit, which corresponds to accumulated nonlinear phase-shifts around 1 rad. This includes a detailed discussion of the influence of the nonlinear effect self-phase modulation on the output pulse of CPA-systems. An analytical model is presented. Emphasis is placed on the design of novel concepts to control the impact of self-phase modulation. Pulse-shaping is regarded as a powerful tool to accomplish this goal. Novel methods to control the impact of SPM are experimentally demonstrated. The design of these concepts is based on the theoretical findings. Both amplitude- and phase-shaping are studied. Model-based phase-shaping is implemented in a state-of-the-art fiber CPA-system. The influence of the polarization state is also highlighted. Additionally, existing techniques and recent advances are put into context. (orig.)

  5. Pulse Generator

    Science.gov (United States)

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  6. Capacity of columns with splice imperfections

    International Nuclear Information System (INIS)

    Popov, E.P.; Stephen, R.M.

    1977-01-01

    To study the behavior of spliced columns subjected to tensile forces simulating situations which may develop in an earthquake, all of the spliced specimens were tested to failure in tension after first having been subjected to large compressive loads. The results of these tests indicate that the lack of perfect contact at compression splices of columns may not be important, provided that the gaps are shimmed and welding is used to maintain the sections in alignment

  7. The central column structure in SPHEX

    International Nuclear Information System (INIS)

    Duck, R.C.; French, P.A.; Browning, P.K.; Cunningham, G.; Gee, S.J.; al-Karkhy, A.; Martin, R.; Rusbridge, M.G.

    1994-01-01

    SPHEX is a gun injected spheromak in which a magnetised Marshall gun generates and maintains an approximately axisymmetric toroidal plasma within a topologically spherical flux conserving vessel. The central column has been defined as a region of high mean floating potential, f > up to ∼ 150 V, aligned with the geometric axis of the device. It has been suggested that this region corresponds to the open magnetic flux which is connected directly to the central electrode of the gun and links the toroidal annulus (in which f > ∼ 0 V). Poynting vector measurements have shown that the power required to drive toroidal current in the annulus is transmitted out of the column by the coherent 20 kHz mode which pervades the plasma. Measurements of the MHD dynamo in the column indicate an 'antidynamo' electric field due to correlated fluctuations in v and B at the 20 kHz mode frequency which is consistent with the time-averaged Ohm's Law. On shorting the gun electrodes, the density in the column region decays rapidly leaving a 'hole' of radius R c ∼ 7 cm. This agrees with the estimated dimension of the open flux from mean internal B measurements and axisymmetric force-free equilibrium modelling, but is considerably smaller than the radius of ∼ 13 cm inferred from the time-averaged potential. In standard operating conditions the gun delivers a current of I G ∼ 60 kA at V G ∼ 500 V for ∼ 1 ms, driving a toroidal current of I t ∼ 60 kA. Ultimately we wish to understand the mechanism which drives toroidal current in the annulus; the central column is of interest because of the crucial role it plays in this process. (author) 8 refs., 6 figs

  8. Pulsed water jet generated by pulse multiplication

    Czech Academy of Sciences Publication Activity Database

    Dvorský, R.; Sitek, Libor; Sochor, T.

    2016-01-01

    Roč. 23, č. 4 (2016), s. 959-967 ISSN 1330-3651 R&D Projects: GA MŠk(CZ) LO1406; GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : high- pressure pulses * pulse intensifier * pulsed water jet * water hammer effect Subject RIV: JQ - Machines ; Tools Impact factor: 0.723, year: 2016 http://hrcak.srce.hr/163752?lang=en

  9. Design of zeolite ion-exchange columns for wastewater treatment

    International Nuclear Information System (INIS)

    Robinson, S.M.; Arnold, W.D.; Byers, C.H.

    1991-01-01

    Oak Ridge National Laboratory plans to use chabazite zeolites for decontamination of wastewater containing parts-per-billion levels of 90 Sr and 137 Cs. Treatability studies indicate that such zeolites can remove trace amounts of 90 Sr and 137 Cs from wastewater containing high concentrations of calcium and magnesium. These studies who that zeolite system efficiency is dependent on column design and operating conditions. Previous results with bench-scale, pilot-scale, and near-full-scale columns indicate that optimized design of full-scale columns could reduce the volume of spent solids generation by one-half. The data indicate that shortcut scale-up methods cannot be used to design columns to minimize secondary waste generation. Since the secondary waste generation rate is a primary influence on process cost effectiveness, a predictive mathematical model for column design is being developed. Equilibrium models and mass-transfer mechanisms are being experimentally determined for isothermal multicomponent ion exchange (Ca, Mg, Na, Cs, and Sr). Mathematical models of these data to determine the breakthrough curves for different column configurations and operating conditions will be used to optimize the final design of full-scale treatment plant. 32 refs., 6 figs., 3 tabs

  10. Graph Modelling Approach: Application to a Distillation Column

    DEFF Research Database (Denmark)

    Hovelaque, V.; Commault, C.; Bahar, Mehrdad

    1997-01-01

    Introduction, structured systems and digraphs, distillation column model, generic input-output decoupling problem, generic disturbance rejection problem, concluding remarks.......Introduction, structured systems and digraphs, distillation column model, generic input-output decoupling problem, generic disturbance rejection problem, concluding remarks....

  11. SPEEDUPtrademark ion exchange column model

    International Nuclear Information System (INIS)

    Hang, T.

    2000-01-01

    A transient model to describe the process of loading a solute onto the granular fixed bed in an ion exchange (IX) column has been developed using the SpeedUptrademark software package. SpeedUp offers the advantage of smooth integration into other existing SpeedUp flowsheet models. The mathematical algorithm of a porous particle diffusion model was adopted to account for convection, axial dispersion, film mass transfer, and pore diffusion. The method of orthogonal collocation on finite elements was employed to solve the governing transport equations. The model allows the use of a non-linear Langmuir isotherm based on an effective binary ionic exchange process. The SpeedUp column model was tested by comparing to the analytical solutions of three transport problems from the ion exchange literature. In addition, a sample calculation of a train of three crystalline silicotitanate (CST) IX columns in series was made using both the SpeedUp model and Purdue University's VERSE-LC code. All test cases showed excellent agreement between the SpeedUp model results and the test data. The model can be readily used for SuperLigtrademark ion exchange resins, once the experimental data are complete

  12. Partial strengthening of R.C square columns using CFRP

    Directory of Open Access Journals (Sweden)

    Ahmed Shaban Abdel-Hay

    2014-12-01

    An experimental program was undertaken testing ten square columns 200 × 200 × 2000 mm. One of them was a control specimen and the other nine specimens were strengthened with CFRP. The main parameters studied in this research were the compressive strength of the upper part, the height of the upper poor concrete part, and the height of CFRP wrapped part of column. The experimental results including mode of failure, ultimate load, concrete strain, and fiber strains were analyzed. The main conclusion of this research was, partial strengthening of square column using CFRP can be permitted and gives good results of the column carrying capacity.

  13. Fire response of composite columns subject to sway

    DEFF Research Database (Denmark)

    Virdi, Kuldeep

    Composite columns, using profiled steel sections encased in concrete or steel tubes filled with concrete, are increasingly used in practice taking advantage of speed of erection as well as offering cost-effective solutions. While the design of braced and unbraced composite columns under ambient...... conditions is adequately covered in the relevant standard, Eurocode 4, simplified design of unbraced composite columns for the fire limit state has not been included. Recognising this, a collaborative research project was undertaken with funding from the Research Fund for Coal and Steel. The paper describes...... the scope of the project which covered control tests under ambient conditions, carried out by the author while at City University London. Other aspects covered in the project included fire tests carried out by CTICM in France, on isolated columns and on two frames designed by Leibniz Universität Hannover...

  14. Cross flow cyclonic flotation column for coal and minerals beneficiation

    Science.gov (United States)

    Lai, Ralph W.; Patton, Robert A.

    2000-01-01

    An apparatus and process for the separation of coal from pyritic impurities using a modified froth flotation system. The froth flotation column incorporates a helical track about the inner wall of the column in a region intermediate between the top and base of the column. A standard impeller located about the central axis of the column is used to generate a centrifugal force thereby increasing the separation efficiency of coal from the pyritic particles and hydrophillic tailings.

  15. Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from pre-column dispersion and volume overload when used alone or with solvent-based focusing.

    Science.gov (United States)

    Groskreutz, Stephen R; Horner, Anthony R; Weber, Stephen G

    2015-07-31

    On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of pre-column dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Control structure selection for energy integrated distillation column

    DEFF Research Database (Denmark)

    Hansen, J.E.; Jørgensen, Sten Bay

    1998-01-01

    This paper treats a case study on control structure selection for an almost binary distillation column. The column is energy integrated with a heat pump in order to transfer heat from the condenser to the reboiler. This integrated plant configuration renders the possible control structures somewhat...... different from what is usual for binary distillation columns. Further the heat pump enables disturbances to propagate faster through the system. The plant has six possible actuators of which three must be used to stabilize the system. Hereby three actuators are left for product purity control. An MILP...

  17. Column gamma-ray scanning of the 'Hector Molina' Distillery

    International Nuclear Information System (INIS)

    Derivet Zarzabal, M.; Capote Ferrera, E.; Fernandez Gomez, I.; Carrazana Gonzalez, L.; Borroto Portela, J.

    2015-01-01

    Gamma-ray scanning, often referred to as 'column scanning', is a convenient, cost effective, fast, efficient and non-invasive technique to examine internal characteristics of a certain equipment, like alcohol distillation columns, while it is in operation. Column scanning allows to engineers, to study hydraulics tray inside of distillation column in on-line condition. It provides essential data to optimize the performance of columns, extend column run times, to evaluate effects of defective track and to identify maintenance requirements. This knowledge can reduce repair times significantly. In the year 2014, the Environmental Radiological Surveillance Laboratory from Center of Radiation Protection and Hygiene, introduced this service in the 'Hector Molina' Distillery. The diagnosis carried out allowed the detection of some anomalies in its operation. In this work the results obtained during gamma-ray scanning of the column are shown. (Author)

  18. Pulsed TRIGA reactor as substitute for long pulse spallation neutron source

    International Nuclear Information System (INIS)

    Whittemore, W.L.

    1999-01-01

    TRIGA reactor cores have been used to demonstrate various pulsing applications. The TRIGA reactor fuel (U-ZrH x ) is very robust especially in pulsing applications. The features required to produce 50 pulses per second have been successfully demonstrated individually, including pulse tests with small diameter fuel rods. A partially optimized core has been evaluated for pulses at 50 Hz with peak pulsed power up to 100 MW and an average power up to 10 MW. Depending on the design, the full width at half power of the individual pulses can range between 2000 μsec to 3000 μsec. Until recently, the relatively long pulses (2000 μsec to 3000 μsec) from a pulsed thermal reactor or a long pulse spallation source (LPSS) have been considered unsuitable for time-of-flight measurements of neutron scattering. More recently considerable attention has been devoted to evaluating the performance of long pulse (1000 to 4000 μs) spallation sources for the same type of neutron measurements originally performed only with short pulses from spallation sources (SPSS). Adequate information is available to permit meaningful comparisons between CW, SPSS, and LPSS neutron sources. Except where extremely high resolution is required (fraction of a percent), which does require short pulses, it is demonstrated that the LPSS source with a 1000 msec or longer pulse length and a repetition rate of 50 to 60 Hz gives results comparable to those from the 60 MW ILL (CW) source. For many of these applications the shorter pulse is not necessarily a disadvantage, but it is not an advantage over the long pulse system. In one study, the conclusion is that a 5 MW 2000 μsec LPSS source improves the capability for structural biology studies of macromolecules by at least a factor of 5 over that achievable with a high flux reactor. Recent studies have identified the advantages and usefulness of long pulse neutron sources. It is evident that the multiple pulse TRIGA reactor can produce pulses comparable to

  19. Buckling of liquid columns

    NARCIS (Netherlands)

    Habibi, M.; Rahmani, Y.; Bonn, D.; Ribe, N.M.

    2010-01-01

    Under appropriate conditions, a column of viscous liquid falling onto a rigid surface undergoes a buckling instability. Here we show experimentally and theoretically that liquid buckling exhibits a hitherto unsuspected complexity involving three different modes—viscous, gravitational, and

  20. Hemifield columns co-opt ocular dominance column structure in human achiasma.

    Science.gov (United States)

    Olman, Cheryl A; Bao, Pinglei; Engel, Stephen A; Grant, Andrea N; Purington, Chris; Qiu, Cheng; Schallmo, Michael-Paul; Tjan, Bosco S

    2018-01-01

    In the absence of an optic chiasm, visual input to the right eye is represented in primary visual cortex (V1) in the right hemisphere, while visual input to the left eye activates V1 in the left hemisphere. Retinotopic mapping In V1 reveals that in each hemisphere left and right visual hemifield representations are overlaid (Hoffmann et al., 2012). To explain how overlapping hemifield representations in V1 do not impair vision, we tested the hypothesis that visual projections from nasal and temporal retina create interdigitated left and right visual hemifield representations in V1, similar to the ocular dominance columns observed in neurotypical subjects (Victor et al., 2000). We used high-resolution fMRI at 7T to measure the spatial distribution of responses to left- and right-hemifield stimulation in one achiasmic subject. T 2 -weighted 2D Spin Echo images were acquired at 0.8mm isotropic resolution. The left eye was occluded. To the right eye, a presentation of flickering checkerboards alternated between the left and right visual fields in a blocked stimulus design. The participant performed a demanding orientation-discrimination task at fixation. A general linear model was used to estimate the preference of voxels in V1 to left- and right-hemifield stimulation. The spatial distribution of voxels with significant preference for each hemifield showed interdigitated clusters which densely packed V1 in the right hemisphere. The spatial distribution of hemifield-preference voxels in the achiasmic subject was stable between two days of testing and comparable in scale to that of human ocular dominance columns. These results are the first in vivo evidence showing that visual hemifield representations interdigitate in achiasmic V1 following a similar developmental course to that of ocular dominance columns in V1 with intact optic chiasm. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Method for pulse to pulse dose reproducibility applied to electron linear accelerators

    International Nuclear Information System (INIS)

    Ighigeanu, D.; Martin, D.; Oproiu, C.; Cirstea, E.; Craciun, G.

    2002-01-01

    An original method for obtaining programmed beam single shots and pulse trains with programmed pulse number, pulse repetition frequency, pulse duration and pulse dose is presented. It is particularly useful for automatic control of absorbed dose rate level, irradiation process control as well as in pulse radiolysis studies, single pulse dose measurement or for research experiments where pulse-to-pulse dose reproducibility is required. This method is applied to the electron linear accelerators, ALIN-10 of 6.23 MeV and 82 W and ALID-7, of 5.5 MeV and 670 W, built in NILPRP. In order to implement this method, the accelerator triggering system (ATS) consists of two branches: the gun branch and the magnetron branch. ATS, which synchronizes all the system units, delivers trigger pulses at a programmed repetition rate (up to 250 pulses/s) to the gun (80 kV, 10 A and 4 ms) and magnetron (45 kV, 100 A, and 4 ms).The accelerated electron beam existence is determined by the electron gun and magnetron pulses overlapping. The method consists in controlling the overlapping of pulses in order to deliver the beam in the desired sequence. This control is implemented by a discrete pulse position modulation of gun and/or magnetron pulses. The instabilities of the gun and magnetron transient regimes are avoided by operating the accelerator with no accelerated beam for a certain time. At the operator 'beam start' command, the ATS controls electron gun and magnetron pulses overlapping and the linac beam is generated. The pulse-to-pulse absorbed dose variation is thus considerably reduced. Programmed absorbed dose, irradiation time, beam pulse number or other external events may interrupt the coincidence between the gun and magnetron pulses. Slow absorbed dose variation is compensated by the control of the pulse duration and repetition frequency. Two methods are reported in the electron linear accelerators' development for obtaining the pulse to pulse dose reproducibility: the method

  2. Structural Decoupling and Disturbance Rejection in a Distillation Column

    DEFF Research Database (Denmark)

    Bahar, Mehrdad; Jantzen, Jan; Commault, C.

    1996-01-01

    Introduction, distillation column model, input-output decoupling, disturbance rejection, concluding remarks, references.......Introduction, distillation column model, input-output decoupling, disturbance rejection, concluding remarks, references....

  3. Cervical column morphology and craniofacial profiles in monozygotic twins.

    Science.gov (United States)

    Sonnesen, Liselotte; Pallisgaard, Carsten; Kjaer, Inger

    2008-02-01

    Previous studies have described the relationships between cervical column morphology and craniofacial morphology. The aims of the present study were to describe cervical column morphology in 38 pairs of adult monozygotic (MZ) twins, and compare craniofacial morphology in twins with fusions with craniofacial morphology in twins without fusion. Visual assessment of cervical column morphology and cephalometric measurements of craniofacial morphology were performed on profile radiographs. In the cervical column, fusion between corpora of the second and third vertebrae was registered as fusion. In the twin group, 8 twin pairs had fusion of the cervical column in both individuals within the pair (sub-group A), 25 pairs had no fusions (subgroup B), and in 5 pairs, cervical column morphology was different within the pair (subgroup C), as one twin had fusion and the other did not. Comparison of craniofacial profiles showed a tendency to increased jaw retrognathia, larger cranial base angle, and larger mandibular inclination in subgroup A than in subgroup B. The same tendency was observed within subgroup C between the individual twins with fusion compared with those without fusion. These results confirm that cervical fusions and craniofacial morphology may be interrelated in twins when analysed on profile radiographs. The study also documents that differences in cervical column morphology can occur in individuals within a pair of MZ twins. It illustrates that differences in craniofacial morphology between individuals within a pair of MZ twins can be associated with cervical fusion.

  4. High-field fMRI unveils orientation columns in humans.

    Science.gov (United States)

    Yacoub, Essa; Harel, Noam; Ugurbil, Kâmil

    2008-07-29

    Functional (f)MRI has revolutionized the field of human brain research. fMRI can noninvasively map the spatial architecture of brain function via localized increases in blood flow after sensory or cognitive stimulation. Recent advances in fMRI have led to enhanced sensitivity and spatial accuracy of the measured signals, indicating the possibility of detecting small neuronal ensembles that constitute fundamental computational units in the brain, such as cortical columns. Orientation columns in visual cortex are perhaps the best known example of such a functional organization in the brain. They cannot be discerned via anatomical characteristics, as with ocular dominance columns. Instead, the elucidation of their organization requires functional imaging methods. However, because of insufficient sensitivity, spatial accuracy, and image resolution of the available mapping techniques, thus far, they have not been detected in humans. Here, we demonstrate, by using high-field (7-T) fMRI, the existence and spatial features of orientation- selective columns in humans. Striking similarities were found with the known spatial features of these columns in monkeys. In addition, we found that a larger number of orientation columns are devoted to processing orientations around 90 degrees (vertical stimuli with horizontal motion), whereas relatively similar fMRI signal changes were observed across any given active column. With the current proliferation of high-field MRI systems and constant evolution of fMRI techniques, this study heralds the exciting prospect of exploring unmapped and/or unknown columnar level functional organizations in the human brain.

  5. Radial heterogeneity of some analytical columns used in high-performance liquid chromatography.

    Science.gov (United States)

    Abia, Jude A; Mriziq, Khaled S; Guiochon, Georges A

    2009-04-10

    An on-column electrochemical microdetector was used to determine accurately the radial distribution of the mobile phase velocity and of the column efficiency at the exit of three common analytical columns, namely a 100 mm x 4.6mm C18 bonded silica-based monolithic column, a 150 mm x 4.6mm column packed with 2.7 microm porous shell particles of C18 bonded silica (HALO), and a 150 mm x 4.6mm column packed with 3 microm fully porous C18 bonded silica particles (LUNA). The results obtained demonstrate that all three columns are not radially homogeneous. In all three cases, the efficiency was found to be lower in the wall region of the column than in its core region (the central core with a radius of 1/3 the column inner radius). The decrease in local efficiency from the core to the wall regions was lower in the case of the monolith (ca. 25%) than in that of the two particle-packed columns (ca. 35-50%). The mobile phase velocity was found to be ca. 1.5% higher in the wall than in the core region of the monolithic column while, in contrast, it was ca. 2.5-4.0% lower in the wall region for the two particle-packed columns.

  6. Characterization of retentivity of reversed phase liquid chromatography columns.

    Science.gov (United States)

    Ying, P T; Dorsey, J G

    1991-03-01

    There are dozens of commercially available reversed phase columns, most marketed as C-8 or C-18 materials, but with no useful way of classifying their retentivity. A useful way of ranking these columns in terms of column "strength" or retentivity is presented. The method utilizes a value for ln k'(w), the estimated retention of a solute from a mobile phase of 100% water, and the slope of the plot of ln k' vsE(T)(30), the solvent polarity. The method is validated with 26 solutes varying in ln k'(w) from about 2 to over 20, on 14 different reversed phase columns. In agreement with previous work, it is found that the phase volume ratio of the column is the most important parameter in determining retentivity. It is strongly suggested that manufacturers adopt a uniform method of calculating this value and that it be made available in advertising, rather than the uninterpretable "% carbon".

  7. Narrowband pulse-enhanced upconversion of chirped broadband pulses

    International Nuclear Information System (INIS)

    Zhao, Kun; Yuan, Peng; Zhong, Haizhe; Zhang, Dongfang; Zhu, Heyuan; Qian, Liejia; Chen, Liezun; Wen, Shuangchun

    2010-01-01

    We propose and demonstrate an efficient sum-frequency mixing scheme based on narrowband and chirped broadband pulses. It combines the advantages of wider spectral acceptance bandwidth and of alleviating the temporal walk-off, which are both beneficial to higher conversion efficiency. Chirped sum-frequency pulses at 455 nm with energy up to 360 µJ, corresponding to a conversion efficiency of ∼ 40%, are obtained and the pulses can be compressed to ∼ 110 fs. The sum-frequency mixing scheme may provide a promising route to the efficient generation of deep-ultraviolet femtosecond pulses

  8. Seismic performance of recycled concrete-filled square steel tube columns

    Science.gov (United States)

    Chen, Zongping; Jing, Chenggui; Xu, Jinjun; Zhang, Xianggang

    2017-01-01

    An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.

  9. Tritium isotope separation by water distillation column packed with silica-gel beads

    International Nuclear Information System (INIS)

    Fukada, Satoshi

    2004-01-01

    Tritium enrichment or depletion by water distillation was investigated using a glass column of 32cm in height packed with silica-gel beads of 3.4mm in average diameter. The total separation factor of the silica-gel distillation column, α H-T , was compared with those of an open column distillation tower and of a column packed with stainless-steel Dixon rings. Depletion of the tritium activity in the distillate was enhanced by isotopic exchange with water absorbed on silica-gel beads that have a higher affinity for HTO than for H 2 O. The value of α H-T -1 of the silica-gel distillation column was about four times larger than that of a column without any packing and about two times larger than that of the Dixon-ring column. The improvement of α H-T by the silica-gel adsorbent indicated that the height of the distillation-adsorption column becomes shorter than that of the height of conventional distillation columns. (author)

  10. Determination of carbohydrates by high performance anion chromatography-pulsed amperometric detection in mushrooms.

    Science.gov (United States)

    Zhou, Shuai; Tang, Qingjiu; Luo, Xi; Xue, Jun-Jie; Liu, Yanfang; Yang, Yan; Zhang, Jingsong; Feng, Na

    2012-01-01

    A method of detecting carbohydrates (fucose, trehalose, mannitol, arabitol, mannose, glucose, galactose, fructose, and ribose) by high-performance anion chromatography-pulsed amperometric detection (HAPEC-PAD) was established. The conditions are: CarboPac MA1 column, NaOH as the eluent, temperature 30°C, Au working electrode, Ag/AgCl reference electrode, and flow rate 0.4 mL/min. These nine analytes, which yielded high resolution by this method, could be detected in 40 minutes. Mushrooms were tested and good precision, stability, and reproducibility were achieved. This method is suitable for mushroom samples and could support research and development on sugar and sugar alcohol, which contains special effects.

  11. Input-Output Decoupling of a Distillation Column LV-Configuration

    DEFF Research Database (Denmark)

    Yazdi, H.; Jørgensen, Sten Bay; Bahar (fratrådt), Mehrdad

    1996-01-01

    Introduction, digraph approach, distillation column, digraph analysis, solution analysis, discussion and conclusion, references.......Introduction, digraph approach, distillation column, digraph analysis, solution analysis, discussion and conclusion, references....

  12. International Year of Pulses 2016 | 2016 International Year of Pulses

    Science.gov (United States)

    the Year in collaboration with Governments, relevant organizations, non-governmental organizations and the composition of pulses Image 4 Wrapping up the International Year of Pulses The 5 key messages to food security Infographic Pulses and climate change International Year of Pulses 2016 The 68th UN

  13. Short steel and concrete columns under high temperatures

    Directory of Open Access Journals (Sweden)

    A. E. P. G. A. Jacintho

    Full Text Available The growing demand for knowledge about the effect of high temperatures on structures has stimulated increasing research worldwide. This article presents experimental results for short composite steel and concrete columns subjected to high temperatures in ovens with or without an axial compression load, numerically analyzes the temperature distribution in these columns after 30 and 60 minutes and compares them with experimental results. The models consist of concrete-filled tubes of three different thicknesses and two different diameters, and the concrete fill has conventional properties that remained constant for all of the models. The stress-strain behavior of the composite columns was altered after exposure to high temperatures relative to the same columns at room temperature, which was most evident in the 60-minute tests due to the higher temperatures reached. The computational analysis adopted temperature rise curves that were obtained experimentally.

  14. Bubble column fermenter modeling: a comparison for pressure effects

    Energy Technology Data Exchange (ETDEWEB)

    Shioya, S; Dang, N D.P.; Dunn, I J

    1978-01-01

    Two models which describe the oxygen transfer, oxygen uptake, and axial mixing in a bubble column fermenter are described. Model I includes no pressure effects and can be solved analytically. Model II incorporates the influence of hydrostatic pressure on oxygen solubility and gas expansion and must be solved numerically. The liquid phase oxygen concentration profiles from both models are compared to ascertain for what parametric conditions and for what maximum column height Model I is valid. Results show that for many situations Model I can approximate the oxygen profiles in a 10 m column within 20%. As the transfer and uptake rates increase, the deviation of Model I can reach 80% for a 10 m column. 7 figures.

  15. HPLC separation of triacylglycerol positional isomers on a polymeric ODS column.

    Science.gov (United States)

    Kuroda, Ikuma; Nagai, Toshiharu; Mizobe, Hoyo; Yoshimura, Nobuhito; Gotoh, Naohiro; Wada, Shun

    2008-07-01

    A polymeric ODS column was applied to the resolution of triacylglycerol positional isomers (TAG-PI), i.e. 1,3-dioleoyl-2-palmitoyl-glycerol (OPO) and 1,2-dioleoyl-3-palmitoyl-rac-glycerol (OOP), with a recycle HPLC system. To investigate the ODS column species and the column temperatures for the resolution of a TAG-PI pair, a mixture of OPO and OOP was subjected to an HPLC system equipped with a non-endcapped polymeric, endcapped monomeric, endcapped intermediate, or non-endcapped monomeric ODS column at three different column temperatures (40, 25, or 10 degrees C). Only the non-endcapped polymeric ODS column achieved the separation of OPO and OOP, and the lowest column temperature (10 degrees C) showed the best resolution for them. The other pair of TAG-PI, a mixture of 1,3-dipalmitoyl-2-oleoyl-glycerol (POP) and 1,2-dipalmitoyl-3-oleoyl-rac-glycerol (PPO) was also subjected to the system equipped with a non-endcapped polymeric or monomeric ODS column at five different column temperatures (40, 32, 25, 17, and 10 degrees C). Thus, POP and PPO were also separated on only the non-endcapped polymeric ODS column at 25 degrees C. However, no clear peak appeared at 10 degrees C. These results would indicate that the polymeric ODS stationary phase has an ability to recognize the structural differences between TAG-PI pairs. Also, the column temperature is a very important factor for separating the TAG-PI pair, and the optimal temperature would relate to the solubility of TAG-PI in the mobile phase. Furthermore, the recycle HPLC system provided measurements for the separation and analysis of TAG-PI pairs.

  16. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  17. Comparative study of the performance of columns packed with several new fine silica particles. Would the external roughness of the particles affect column properties?

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2007-09-28

    We measured and compared the characteristics and performance of columns packed with particles of five different C(18)-bonded silica, 3 and 5 microm Luna, 3 microm Atlantis, 3.5 microm Zorbax, and 2.7 microm Halo. The average particle size of each material was derived from the SEM pictures of 200 individual particles. These pictures contrast the irregular morphology of the external surface of the Zorbax and Halo particles and the smooth surface of the Luna and Atlantis particles. In a wide range of mobile phase velocities (from 0.010 to 3 mL/min) and at ambient temperature, we measured the first and second central moments of the peaks of naphthalene, insulin, and bovine serum albumin (BSA). These moments were corrected for the contributions of the extra-column volumes to calculate the reduced HETPs. The C-terms of naphthalene and insulin are largest for the Halo and Zorbax materials and the A-term smallest for the Halo-packed column. The Halo column performs the best for the low molecular weight compound naphthalene (minimum reduced HETP, 1.4) but is not as good as the Atlantis or Luna columns for the large molecular weight compound insulin. The Zorbax column is the least efficient column because of its large C-term. The lowest sample diffusivity through these particles, alone, does not account for the results. It is most likely that the roughness of the external surface of the Halo and Zorbax particles limit the performance of these columns at high flow rates generating an unusually high film mass transfer resistance.

  18. Lighting columns. Research on the behaviour of lighting columns in sideways- on and head-on impact tests with private cars.

    NARCIS (Netherlands)

    1978-01-01

    Lighting columns can be made more safe by providing them with a sliding construction. This construction makes it possible that the column slides from his ground construction in case of an accident. Aluminium lighting can be constructed in such a way that the break off in case of a car collides

  19. Distillation columns inspection through gamma scanning

    International Nuclear Information System (INIS)

    Garcia, Marco

    1999-09-01

    The application of nuclear energy is very wide and it allows the saving of economic resources since the investigation of a certain process is carried out without stop the plant. The gamma scanning of oil c racking c olumns are practical examples, they allow to determine the hydraulic operation of the inspected columns. A source of Co-60 22mCi and a detector with a crystal of INa(TI) are used. This paper shows the results got from a profile carried out in a column distillation

  20. The instability analysis of the cryogenic distillation column condenser

    International Nuclear Information System (INIS)

    David, Claudia; Stefanescu, Ioan; Vasut, Felicia; Preda, Anisoara; Ghitulescu, Alina

    2008-01-01

    Full text: The column plays the main part of the process in a distillation plant for hydrogen isotopes. The variable parameters like vaporizer power or liquid hydrogen level fluctuation can induce non-steady states which lead to performance decrease of the process. In the paper the liquid hydrogen fluctuation from the cryogenic column condenser is taken into account. This fluctuation determines the variation of the gas holdup from the top of the column. It was considered a column equipped with order package, NT theoretical plates, H height and fed with a deuterium-tritium mixture. A mathematical model was developed based on the balance equations in the column, on every plate and in the condenser. As fluctuation of the level in the condenser a sinusoidal function was considered. The program developed was used for some cases with input data variables like: initial concentration of tritium in the mixture, the amplitude and period of the sinusoidal function. It was calculated the height of the transfer unit as the ratio of the column height to the Fenske number and it was determined the time for entrance in steady state. The results were presented in a master table. There were given also diagrams. There were analyzed the results. (authors)

  1. Pulsed time-of-flight refractometry measurements of the electron density in the T-11M tokamak

    International Nuclear Information System (INIS)

    Petrov, A.A.; Petrov, V.G.; Malyshev, A.Yu.; Markov, V.K.; Babarykin, A.V.

    2002-01-01

    A new method for measuring the plasma density in magnetic confinement systems - pulsed time-of-flight refractometry - is developed and tested experimentally in the T-11M tokamak. The method is based on the measurements of the time delay of short (with a duration of several nanoseconds) microwave pulses propagating through the plasma. When the probing frequency is much higher than the plasma frequency, the measured delay in the propagation time is proportional to the line-averaged electron density regardless of the density profile. A key problem in such measurements is the short time delay of the pulse in the plasma (∼1 ns or less for small devices) and, consequently, low accuracy of the measurements of the average density. Various methods for improving the accuracy of such measurements are proposed and implemented in the T-11M experiments. The measurements of the line-averaged density in the T-11M tokamak in the low-density plasma regime are performed. The results obtained agree satisfactorily with interferometric data. The measurement errors are analyzed, and the possibility of using this technique to measure the electron density profile and the position of the plasma column is discussed

  2. Programmable pulse generator

    International Nuclear Information System (INIS)

    Xue Zhihua; Lou Binqiao; Duan Xiaohui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  3. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors.

    Science.gov (United States)

    Liu, Jing; Gupta, Naveen K; Wise, Kensall D; Gianchandani, Yogesh B; Fan, Xudong

    2011-10-21

    This paper reports the investigation of a micro-gas chromatography (μGC) system that utilizes an array of miniaturized motionless Knudsen pumps (KPs) as well as microfabricated separation columns and optical detectors. A prototype system was built to achieve a flow rate of 1 mL min(-1) and 0.26 mL min(-1) for helium and dry air, respectively, when they were used as carrier gas. This system was then employed to evaluate GC performance compromises and demonstrate the ability to separate and detect gas mixtures containing analytes of different volatilities and polarities. Furthermore, the use of pressure programming of the KP array was demonstrated to significantly shorten the analysis time while maintaining a high detection resolution. Using this method, we obtained a high resolution detection of 5 alkanes of different volatilities within 5 min. Finally, we successfully detected gas mixtures of various polarities using a tandem-column μGC configuration by installing two on-column optical detectors to obtain complementary chromatograms.

  4. Impact of Holes on the Buckling of RHS Steel Column

    Directory of Open Access Journals (Sweden)

    Najla'a H. AL-Shareef

    2018-03-01

    Full Text Available This study presented an experimental and theoretical study on the effect of hole on the behavior of rectangular hollow steel columns subjected to axial compression load. Specimens were tested to investigated the ultimate capacity and the load- axial displacement behavior of steel columns. In this paper finite element analysis is done by using general purpose ANSYS 12.0 to investigate the behavior of rectangular hollow steel column with hole. In the experimental work, rectangular hollow steel columns with rounded corners were used in the constriction of the specimens which have dimensions of cross section (50*80mm and height of (250 and 500mm with thickness of (1.25,4 and 6mm with hole ((α*80*80mm when α is equal to (0.2,0.4,0.6 and 0.8. Twenty four columns under compression load were tested in order to investigate the effect of hole on the ultimate load of rectangular hollow steel column. The experimental results indicated that the typical failure  mode for all the tested hollow specimen was the local buckling. The tested results indicated that the increasing of hole dimension leads to reduction in ultimate loads of tested column to 75%. The results show the reducing of load by 94.7% due to decreasing  the thickness of  column while the hole size is constant (0.2*80*80. The buckling load decreases by 84.62% when hole position changes from Lo=0.25L to 0.75L. Holes can be made in the middle of column with dimension up to 0.4 of column's length. The AISC (2005 presents the values closest to the experimental results for the nominal yielding compressive strength. The effect for increasing of slendeness ratio and thickness to area ratio(t/A leading to decreacing the critical stresses and the failure of column with large size of hole and (t/A ratio less than 0.74% was due to lacal  buckling while the global buckling failure was abserve for column with small size of hole and (t/A ratio above than 0.74%. The compersion  between the experimental

  5. Column-by-column compositional mapping by Z-contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Molina, S.I. [Departamento de Ciencia de los Materiales e I.M. y Q.I., Facultad de Ciencias, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain)], E-mail: sergio.molina@uca.es; Sales, D.L. [Departamento de Ciencia de los Materiales e I.M. y Q.I., Facultad de Ciencias, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain); Galindo, P.L. [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Campus Rio San Pedro, s/n, 11510 Puerto Real, Cadiz (Spain); Fuster, D.; Gonzalez, Y.; Alen, B.; Gonzalez, L. [Instituto de Microelectronica de Madrid (CNM, CSIC), Isaac Newton 8, 28760 Tres Cantos, Madrid (Spain); Varela, M.; Pennycook, S.J. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2009-01-15

    A phenomenological method is developed to determine the composition of materials, with atomic column resolution, by analysis of integrated intensities of aberration-corrected Z-contrast scanning transmission electron microscopy images. The method is exemplified for InAs{sub x}P{sub 1-x} alloys using epitaxial thin films with calibrated compositions as standards. Using this approach we have determined the composition of the two-dimensional wetting layer formed between self-assembled InAs quantum wires on InP(0 0 1) substrates.

  6. Effects of pulse-to-pulse residual species on discharges in repetitively pulsed discharges through packed bed reactors

    Science.gov (United States)

    Kruszelnicki, Juliusz; Engeling, Kenneth W.; Foster, John E.; Kushner, Mark J.

    2016-09-01

    Atmospheric pressure dielectric barrier discharges (DBDs) sustained in packed bed reactors (PBRs) are being investigated for conversion of toxic and waste gases, and CO2 removal. These discharges are repetitively pulsed having varying flow rates and internal geometries, which results in species from the prior pulse still being in the discharge zone at the time the following discharge pulse occurs. A non-negligible residual plasma density remains, which effectively acts as preionization. This residual charge changes the discharge properties of subsequent pulses, and may impact important PBR properties such as chemical selectivity. Similarly, the residual neutral reactive species produced during earlier pulses will impact the reaction rates on subsequent pulses. We report on results of a computational investigation of a 2D PBR using the plasma hydrodynamics simulator nonPDPSIM. Results will be discussed for air flowing though an array of dielectric rods at atmospheric pressure. The effects of inter-pulse residual species on PBR discharges will be quantified. Means of controlling the presence of residual species in the reactor through gas flow rate, pulse repetition, pulse width and geometry will be described. Comparisons will be made to experiments. Work supported by US DOE Office of Fusion Energy Science and the National Science Foundation.

  7. Ultimate strength and ductility of steel reinforced concrete beam-columns

    International Nuclear Information System (INIS)

    Shohara, Ryoichi

    1991-01-01

    The ultimate strength and ductility of SRC beam-columns are investigated using the data gathered in Architectural Institute of Japan. Though the simple superposed strength formula in AIJ standard underestimates the strength of SRC beam-column failed in flexure, the generalized superposed strength formula estimates it satisfactory. The strength formula in AIJ standard does not good agreement with test data. The SRC beam-column failed in shear has almost equalductility with that failed in flexure owing to the encased steel. Author presents the formulas which estimate the ultimate deformation angle for SRC beam-columns. (author)

  8. One column method to prepare 11C-labelled methyl iodide

    International Nuclear Information System (INIS)

    Kovacs, Z.; Priboczki, E.

    1999-01-01

    A new method in which the [ 11 C]methyl iodide is prepared on one alumina column is presented. A high specific surface alumina column, previously impregnated with lithium aluminium hydride solution, was used for direct trapping from the target gas and reduction into radiocomplex. The complex was then reacted on this column with HI to form [ 11 C]methyl iodide. The use of one alumina column, instead of a freezing trap, reaction vessel and separate unit for iodination, simplifies the apparatus, shortens the synthesis time and is well suitable for automation. (K.A.)

  9. Evaluation of Controller Tuning Methods Applied to Distillation Column Control

    DEFF Research Database (Denmark)

    Nielsen, Kim; W. Andersen, Henrik; Kümmel, Professor Mogens

    A frequency domain approach is used to compare the nominal performance and robustness of dual composition distillation column control tuned according to Ziegler-Nichols (ZN) and Biggest Log Modulus Tuning (BLT) for three binary distillation columns, WOBE, LUVI and TOFA. The scope of this is to ex......A frequency domain approach is used to compare the nominal performance and robustness of dual composition distillation column control tuned according to Ziegler-Nichols (ZN) and Biggest Log Modulus Tuning (BLT) for three binary distillation columns, WOBE, LUVI and TOFA. The scope...

  10. Modeling atrazine transport in soil columns with HYDRUS-1D

    Directory of Open Access Journals (Sweden)

    John Leju Celestino Ladu

    2011-09-01

    Full Text Available Both physical and chemical processes affect the fate and transport of herbicides. It is useful to simulate these processes with computer programs to predict solute movement. Simulations were run with HYDRUS-1D to identify the sorption and degradation parameters of atrazine through calibration from the breakthrough curves (BTCs. Data from undisturbed and disturbed soil column experiments were compared and analyzed using the dual-porosity model. The study results show that the values of dispersivity are slightly lower in disturbed columns, suggesting that the more heterogeneous the structure is, the higher the dispersivity. Sorption parameters also show slight variability, which is attributed to the differences in soil properties, experimental conditions and methods, or other ecological factors. For both of the columns, the degradation rates were similar. Potassium bromide was used as a conservative non-reactive tracer to characterize the water movement in columns. Atrazine BTCs exhibited significant tailing and asymmetry, indicating non-equilibrium sorption during solute transport. The dual-porosity model was verified to best fit the BTCs of the column experiments. Greater or lesser concentration of atrazine spreading to the bottom of the columns indicated risk of groundwater contamination. Overall, HYDRUS-1D successfully simulated the atrazine transport in soil columns.

  11. Internet delivered question and answer column for patients with schizophrenia.

    Science.gov (United States)

    Maijala, Riikka; Anttila, Minna; Koivunen, Marita; Pitkänen, Anneli; Kuosmanen, Lauri; Välimäki, Maritta

    2015-01-01

    The purpose of this study was to describe the use of an Internet delivered question and answer column among patients with schizophrenia. The column was developed for research purposes. The study sample consisted of patients (N = 100) admitted to acute inpatient psychiatric care in two hospital districts. Descriptive data were collected from the column to which a nurse replied within 3 days and analysed using qualitative content analysis. The column had four to five questions weekly. The most common age of users was 18-24 years, and the gender distribution was almost equal. Column use was heaviest among students (44%) and least among unemployed people (19%). Out of 85 questions or comments sent to the column, 25 (29%) were related to program training and the remaining 60 (71%) were related to medication (31%), illness and tests (25%), other questions or comments (9%), daily life and coping with it (4%), and places to receive treatment (2%). An Internet delivered question and answer column can be included in the care of patients with schizophrenia. However, it requires a new type of basic and additional education in the field of mental health care in order for nurses to be able to provide nursing via the Internet forum.

  12. A Modelling Framework for Conventional and Heat Integrated Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    of hydrocarbons such as separations of equimolar mixtures of benzene/toluene or propane/propene described by simple models, a generic, modular, model framework is presented in this work. At present, the framework is able to describe a conventional distillation column, a mechanical vapor recompression column......Diabatic operation of distillation columns can lead to signicant reductions in energy utilization and operation cost compared to conventional (adiabatic) distillation columns, at an expense of an increased complexity of design and operation. The earliest diabatic distillation conguration dates back...... to the late 70s, and various dierent congurations have appeared since. However, at present, no full-scale diabatic distillation columns are currently operating in the industry. Current studies related to alternative distillation congurations report very dierent gures for potential energy savings which...

  13. Reliability of a four-column classification for tibial plateau fractures.

    Science.gov (United States)

    Martínez-Rondanelli, Alfredo; Escobar-González, Sara Sofía; Henao-Alzate, Alejandro; Martínez-Cano, Juan Pablo

    2017-09-01

    A four-column classification system offers a different way of evaluating tibial plateau fractures. The aim of this study is to compare the intra-observer and inter-observer reliability between four-column and classic classifications. This is a reliability study, which included patients presenting with tibial plateau fractures between January 2013 and September 2015 in a level-1 trauma centre. Four orthopaedic surgeons blindly classified each fracture according to four different classifications: AO, Schatzker, Duparc and four-column. Kappa, intra-observer and inter-observer concordance were calculated for the reliability analysis. Forty-nine patients were included. The mean age was 39 ± 14.2 years, with no gender predominance (men: 51%; women: 49%), and 67% of the fractures included at least one of the posterior columns. The intra-observer and inter-observer concordance were calculated for each classification: four-column (84%/79%), Schatzker (60%/71%), AO (50%/59%) and Duparc (48%/58%), with a statistically significant difference among them (p = 0.001/p = 0.003). Kappa coefficient for intr-aobserver and inter-observer evaluations: Schatzker 0.48/0.39, four-column 0.61/0.34, Duparc 0.37/0.23, and AO 0.34/0.11. The proposed four-column classification showed the highest intra and inter-observer agreement. When taking into account the agreement that occurs by chance, Schatzker classification showed the highest inter-observer kappa, but again the four-column had the highest intra-observer kappa value. The proposed classification is a more inclusive classification for the posteromedial and posterolateral fractures. We suggest, therefore, that it be used in addition to one of the classic classifications in order to better understand the fracture pattern, as it allows more attention to be paid to the posterior columns, it improves the surgical planning and allows the surgical approach to be chosen more accurately.

  14. Experimental and Numerical Study of FRP Encased Composite Concrete Columns

    Directory of Open Access Journals (Sweden)

    Mohsen Ishaghian

    2017-02-01

    Full Text Available A new type of composite column is presented and assessed through experimental testing and numerical modeling. The objective of this research is to investigate design options for a composite column without the use of ferrous materials. This is to avoid the current problem of deterioration of concrete due to expansion of rusting reinforcement members. Such a target can be achieved by replacing the steel reinforcement of concrete columns with pultruded I-shape glass FRP structural sections. The composite column utilizes a glass FRP tube that surrounds a pultruded I-section glass FRP, which is subsequently filled with concrete. The GFRP tube acts as a stay-in-place form in addition to providing confinement to the concrete. A total of four composite columns were tested under monotonic axial loading. The experimental ultimate capacity of each of the tested composite column was compared to the predicted numerical capacity using ANSYS program. The comparison showed that the predicted numerical values were in good agreement with the experimental ones.

  15. Ultrasonic testing device having an adjustable water column

    Science.gov (United States)

    Roach, Dennis P.; Neidigk, Stephen O.; Rackow, Kirk A.; Duvall, Randy L.

    2015-09-01

    An ultrasonic testing device having a variable fluid column height is disclosed. An operator is able to adjust the fluid column height in real time during an inspection to to produce optimum ultrasonic focus and separate extraneous, unwanted UT signals from those stemming from the area of interest.

  16. Optimization of the bending stiffness of beam-to-column and column-to-foundation connections in precast concrete structures

    Directory of Open Access Journals (Sweden)

    R. R. R. COSTA

    Full Text Available Abstract This work involved the structural optimization of precast concrete rigid frames with semi-rigid beam-to-column connections. To this end, several frames were simulated numerically using the Finite Element Method. Beams and columns were modeled using bar elements and their connections were modeled using spring elements, with variable bending stiffness. The objective function was based on the search of the least stiff connection able to ensure the global stability of the building. Lastly, a connection model with optimal stiffness was adopted to design the frame. Semi-rigid beam-to-column connections with a constraint factors of 0.33 sufficed to ensure the maximum allowable horizontal displacement and bending moment of the connection, with a global stability parameter of 1.12. This confirms that even connections with low constraints generate significant gains from the structural standpoint, without affecting construction and assembly-related aspects.

  17. Topographic shear and the relation of ocular dominance columns to orientation columns in primate and cat visual cortex.

    Science.gov (United States)

    Wood, Richard J.; Schwartz, Eric L.

    1999-03-01

    Shear has been known to exist for many years in the topographic structure of the primary visual cortex, but has received little attention in the modeling literature. Although the topographic map of V1 is largely conformal (i.e. zero shear), several groups have observed topographic shear in the region of the V1/V2 border. Furthermore, shear has also been revealed by anisotropy of cortical magnification factor within a single ocular dominance column. In the present paper, we make a functional hypothesis: the major axis of the topographic shear tensor provides cortical neurons with a preferred direction of orientation tuning. We demonstrate that isotropic neuronal summation of a sheared topographic map, in the presence of additional random shear, can provide the major features of cortical functional architecture with the ocular dominance column system acting as the principal source of the shear tensor. The major principal axis of the shear tensor determines the direction and its eigenvalues the relative strength of cortical orientation preference. This hypothesis is then shown to be qualitatively consistent with a variety of experimental results on cat and monkey orientation column properties obtained from optical recording and from other anatomical and physiological techniques. In addition, we show that a recent result of Das and Gilbert (Das, A., & Gilbert, C. D., 1997. Distortions of visuotopic map match orientation singularities in primary visual cortex. Nature, 387, 594-598) is consistent with an infinite set of parameterized solutions for the cortical map. We exploit this freedom to choose a particular instance of the Das-Gilbert solution set which is consistent with the full range of local spatial structure in V1. These results suggest that further relationships between ocular dominance columns, orientation columns, and local topography may be revealed by experimental testing.

  18. Local buckling of composite channel columns

    Science.gov (United States)

    Szymczak, Czesław; Kujawa, Marcin

    2018-05-01

    The investigation concerns local buckling of compressed flanges of axially compressed composite channel columns. Cooperation of the member flange and web is taken into account here. The buckling mode of the member flange is defined by rotation angle a flange about the line of its connection with the web. The channel column under investigation is made of unidirectional fibre-reinforced laminate. Two approaches to member orthotropic material modelling are performed: the homogenization with the aid of theory of mixture and periodicity cell or homogenization upon the Voigt-Reuss hypothesis. The fundamental differential equation of local buckling is derived with the aid of the stationary total potential energy principle. The critical buckling stress corresponding to a number of buckling half-waves is assumed to be a minimum eigenvalue of the equation. Some numerical examples dealing with columns are given here. The analytical results are compared with the finite element stability analysis carried out by means of ABAQUS software. The paper is focused on a close analytical solution of the critical buckling stress and the associated buckling mode while the web-flange cooperation is assumed.

  19. Fiber-based monolithic columns for liquid chromatography.

    Science.gov (United States)

    Ladisch, Michael; Zhang, Leyu

    2016-10-01

    Fiber-based monoliths for use in liquid chromatographic separations are defined by columns packed with aligned fibers, woven matrices, or contiguous fiber structures capable of achieving rapid separations of proteins, macromolecules, and low molecular weight components. A common denominator and motivating driver for this approach, first initiated 25 years ago, was reducing the cost of bioseparations in a manner that also reduced residence time of retained components while achieving a high ratio of mass to momentum transfer. This type of medium, when packed into a liquid chromatography column, minimized the fraction of stagnant liquid and resulted in a constant plate height for non-adsorbing species. The uncoupling of dispersion from eluent flow rate enabled the surface chemistry of the stationary phase to be considered separately from fluid transport phenomena and pointed to new ways to apply chemistry for the engineering of rapid bioseparations. This paper addresses developments and current research on fiber-based monoliths and explains how the various forms of this type of chromatographic stationary phase have potential to provide new tools for analytical and preparative scale separations. The different stationary phases are discussed, and a model that captures the observed constant plate height as a function of mobile phase velocity is reviewed. Methods that enable hydrodynamically stable fiber columns to be packed and operated over a range of mobile phase flow rates, together with the development of new fiber chemistries, are shown to provide columns that extend the versatility of liquid chromatography using monoliths, particularly at the preparative scale. Graphical Abstract Schematic representation of a sample mixture being separated by a rolled-stationary phase column, resulting separated peaks shown in the chromatogram.

  20. Innovation of Iron Reinforcing Column of Partical From Frame of Light Steel

    Science.gov (United States)

    Ramadhan, M. R.; Faslih, A.; Umar, M. Z.

    2018-05-01

    Almost half of houses in Indonesia are using lightweight steel roof truss today. The phenomenon in the field is that lightweight steel roof truss can blend with mortar mixture. Thus this phenomenon is captured for later applied dynamically, creatively, and innovatively with new idioms such as reinforcement for columns. This research aims to investigate the comparison of the way of making and the price of the materials between the column material made of the light steel and the column material made of the iron reinforcement which is the most efficient. Type of research is qualitative with a comparative causal approach. This research is divided into several stages, namely; Literature study, column creation, and validation. This study concluds that the manufacture of column material from reinforcement is more efficient, than the lightweight steel column material. The reinforcement column material is more efficient because of the more effective way of making and the price of the working materials more economical than the lightweight steel column material. Lightweight steel columns can be used for public housing on condition made by experienced craftsmen to make the process faster, and the dimensions of lightweight steel can be scaled down to make it more economical.

  1. Searching for optimal integer solutions to set partitioning problems using column generation

    OpenAIRE

    Bredström, David; Jörnsten, Kurt; Rönnqvist, Mikael

    2007-01-01

    We describe a new approach to produce integer feasible columns to a set partitioning problem directly in solving the linear programming (LP) relaxation using column generation. Traditionally, column generation is aimed to solve the LP relaxation as quick as possible without any concern of the integer properties of the columns formed. In our approach we aim to generate the columns forming the optimal integer solution while simultaneously solving the LP relaxation. By this we can re...

  2. Characteristics of bipolar-pulse generator for intense pulsed heavy ion beam acceleration

    International Nuclear Information System (INIS)

    Igawa, K.; Tomita, T.; Kitamura, I.; Ito, H.; Masugata, K.

    2006-01-01

    Intense pulsed heavy ion beams are expected to be applied to the implantation technology for semiconductor materials. In the application it is very important to purify the ion beam. In order to improve the purity of an intense pulsed ion beams we have proposed a new type of pulsed ion beam accelerator named 'bipolar pulse accelerator (BPA)'. A prototype of the experimental system has been developed to perform proof of principle experiments of the accelerator. A bipolar pulse generator has been designed for the generation of the pulsed ion beam with the high purity via the bipolar pulse acceleration and the electrical characteristics of the generator were evaluated. The production of the bipolar pulse has been confirmed experimentally. (author)

  3. CALCULATION OF SHOCK-WAVE PULSE EFFECT ON OUTSTRETCHED SPINE

    Directory of Open Access Journals (Sweden)

    G. A. Esman

    2011-01-01

    Full Text Available Combined effects of a shock-wave pulse method and mechanotherapy on a spine is considered as an alternative to conservative and operative methods.Methodology for spinal disease treatment while applying a shock-wave therapy is characterized by the following specific features. Firstly, it is necessary to limit a penetration depth of shock pulses in a biological object in order to exclude damage to a spinal cord. Secondly, it is necessary to limit an energy flux density:Imax≤ 0,280 J∕m2and  pressure in focus:PFmax≤ 0,040 MPа,in order to exclude traumatizing of spinal tissue and only stimulate blood  circulation and metabolic processes in them.Where an acceptable value of the force acting on the inter-vertebral disc while a shock wave is passing is determined by the following formula: F max = PFmaxS = PFmax πr02 = 0,040 ∙106 ∙3,14 ∙(8∙10-32 = 9 N, where r0 – a focal spot radius, mm.Mechanotherapy is applied in combination with the shock-wave therapy and it presupposes the following: an outstretching force acts created in a longitudinal direction of the spine and it is directed across a vertebral column, whose value usually ranges from 50 to 500 N.   

  4. Development of the pulse transformer for NLC klystron pulse modulator

    International Nuclear Information System (INIS)

    Akemoto, M.; Gold, S.; Koontz, R.; Krasnykh, A.

    1997-05-01

    We have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests are also presented

  5. Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

    Science.gov (United States)

    Gu, Dongyu; Yang, Yi; Xin, Xuelei; Aisa, Haji Akber; Ito, Yoichiro

    2015-01-01

    A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4 mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW), hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0° column angle (column axis parallel to the centrifugal force) than at 90° column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07 ml/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05 ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-β-ala peaks and 1.81 between DNP-β-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03 ml/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported.

  6. Dynamic Characterization of Fiber Optical Chirped Pulse Amplification for Sub-ps Pulses

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Rishøj, Lars Søgaard

    2013-01-01

    We investigate experimentally the propagation of sub-picosecond pulses in fiber optical parametric chirped pulse amplifiers, showing a significant broadening of the pulses from 450 fs up to 720 fs due to dispersion and self-phase modulation.......We investigate experimentally the propagation of sub-picosecond pulses in fiber optical parametric chirped pulse amplifiers, showing a significant broadening of the pulses from 450 fs up to 720 fs due to dispersion and self-phase modulation....

  7. Sustainable materials used as stone column filler: A short review

    Science.gov (United States)

    Zukri, Azhani; Nazir, Ramli

    2018-04-01

    Stone columns (also known as granular piles) are one of the methods for soft soil stabilization and typically used to increase bearing capacity and stability of slope.; Apart from decreasing the compressibility of loose and fine graded soils, it also accelerates the consolidation effect by improving the drainage path for pore water pressure dissipation and reduces the liquefaction potential of soils during earthquake event. Stone columns are probably the most “natural” ground treatment method or foundation system in existence to date. The benefit of stone columns is owing to the partial replacement of compressible soil by more competent materials such as stone aggregate, sand and other granular materials. These substitutes also act as reinforcement material, hence increasing overall strength and stiffness of the soft soil. Nowadays, a number of research has been conducted on the behaviour and performance of stone columns with various materials utilized as column filler replacing the normal aggregate. This paper will review extensively on previously conducted research on some of the materials used as stone column backfill materials, its suitability and the effectiveness as a substitute for regular aggregates in soft soil improvement works.

  8. Second dimension column ensemble pressure tuning in comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Junior, Ademario I da Silva; Marriott, Philip J

    2018-02-09

    A pressure tunable (PT) coupled column ensemble has been implemented for the second dimension ( 2 D) separation in comprehensive two dimensional gas chromatography (GC×PTGC). This process requires two columns to be connected by a pressure junction, as a replacement for a single narrow bore, short column in 2 D. Various 2 D 1 and 2 D 2 columns may be selected to provide complementary selectivity (polarity) compared to the 1 D column. The tunable residence time arising from differential pressure drop in each 2 D column results in a tunable fractional contribution of each column in the 2 D separation. A sample mixture comprising different chemical classes, including alkanes and alcohols, is used to identify the feasibility and extent of selectivity tuning possible in GC×PTGC. The column length is also varied due to the imposed challenge of wraparound in the PT coupled column system as pressures are adjusted in the 2 D separation. Different experimental parameters, stationary phase materials and column lengths have been applied to investigate and understand the separation behaviour of the 2 D PT coupled column GC×GC system. Results are discussed considering analyte retention time, peak width, linear velocity and the contribution of each 2 D column. A specific and unexpected example of GC×GC separation was demonstrated where the peak positions of polar and apolar compounds could almost swap their 2 D retention position by application of PT. Kerosene was analysed as an example of complex sample analysis by GC×PTGC system. This process is shown to be a practical approach for altering different stationary phase selectivities in a single 2 D arrangement in GC×GC. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Simulation of startup period of hydrogen isotope separation distillation column

    International Nuclear Information System (INIS)

    Sazonov, A.B.; Kagramanov, Z.G.; Magomedbekov, Eh.P.

    2003-01-01

    Kinetic procedure for the mathematical simulation of start-up regime of rectification columns for molecular hydrogen isotope separation was developed. Nonstationary state (start-up period) of separating column for rectification of multi-component mixture was calculated. Full information on equilibrium and kinetic physicochemical properties of components in separating mixtures was used for the calculations. Profile of concentration of components by height of column in task moment of time was calculated by means of differential equilibriums of nonstationary mass transfer. Calculated results of nonstationary state of column by the 2 m height, 30 mm diameter during separation of the mixture: 5 % protium, 70 % deuterium, 25 % tritium were illustrated [ru

  10. Column Chromatography To Obtain Organic Cation Sorption Isotherms.

    Science.gov (United States)

    Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A

    2016-08-02

    Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation.

  11. Graphite oxidation and structural strength of graphite support column in VHTR

    International Nuclear Information System (INIS)

    Park, Byung Ha; No, Hee Cheno; Kim, Eung Soo; Oh, Chang H.

    2009-01-01

    The air-ingress event by a large pipe break is an important accident considered in design of very high-temperature gas-cooled reactors (VHTR). Core-collapse prediction is a main safety issue. Structural failure model are technically required. The objective of this study is to develop structural failure model for the supporting graphite material in the lower plenum of the GT-MHR (gas-turbine-modular high temperature reactor). Graphite support column is important for VHTR structural integrity. Graphite support columns are under the axial load. Critical strength of graphite column is related to slenderness ratio and bulk density. Through compression tests for fresh and oxidized graphite columns we show that compressive strength of IG-110 was 79.46 MPa. And, the buckling strength of IG-110 column was expressed by the empirical formula: σ 0 =σ straight-line - C L/r, σ straight-line =91.31 MPa, C=1.01. The results of uniform and non-uniform oxidation tests show that the strength degradation of oxidized graphite column is expressed in the following non-dimensional form: σ/σ 0 =exp(-kd), k=0.111. Also, from the results of the uniform oxidation test with a complicated-shape column, we found out that the above non-dimensional equation obtained from the uniform oxidation test is applicable to a uniform oxidation case with a complicated-shape column. (author)

  12. Petawatt pulsed-power accelerator

    Science.gov (United States)

    Stygar, William A.; Cuneo, Michael E.; Headley, Daniel I.; Ives, Harry C.; Ives, legal representative; Berry Cottrell; Leeper, Ramon J.; Mazarakis, Michael G.; Olson, Craig L.; Porter, John L.; Wagoner; Tim C.

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  13. PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN

    Directory of Open Access Journals (Sweden)

    İ. Metin HASDEMİR

    1999-03-01

    Full Text Available The influence of feed ratios ((LE/LR on the performance of a packed liquid-liquid extraction column, with a diameter of 5.86 cm and a column height of 132 cm was investigated. The column is made of borosilicate glass and packed with 10 x 10 mm glass Raschig rings. In this study, a ternary system composed of water + propionic acid + trichloroethylene was used. The data used to triangular diagram were obtained experimentally. The overall mass transfer coefficients, the numbers of overall mass transfer units, the heights of mass transfer units, the numbers of theoretical stages and height equivalent to a theoretical stage (H. E. T. S. values were calculated and compared with each other.

  14. Cow-in-a-Column – A Synthetic Food Replicator

    Data.gov (United States)

    National Aeronautics and Space Administration — The project tested the concept for combining waste degradation and food production in a single reactor or column, i.e., a "Cow-in-a-Column".  The inputs could...

  15. Humic colloid-borne migration of uranium in sand columns

    International Nuclear Information System (INIS)

    Artinger, R.; Rabung, T.; Kim, J.I.; Sachs, S.; Schmeide, K.; Heise, K.H.; Bernhard, G.; Nitsche, H.

    2002-09-01

    Column experiments were carried out to investigate the influence of humic colloids on subsurface uranium migration. The columns were packed with well-characterized aeolian quartz sand and equilibrated with groundwater rich in humic colloids (dissolved organic carbon (DOC): 30 mg dm -3 ). U migration was studied under an Ar/1% CO 2 gas atmosphere as a function of the migration time, which was controlled by the flow velocity or the column length. In addition, the contact time of U with groundwater prior to introduction into a column was varied. U(VI) was found to be the dominant oxidation state in the spiked groundwater. The breakthrough curves indicate that U was transported as a humic colloid-borne species with a velocity up to 5% faster than the mean groundwater flow. The fraction of humic colloid-borne species increases with increasing prior contact time and also with decreasing migration time. The migration behavior was attributed to a kinetically controlled association/dissociation of U onto and from humic colloids and also a subsequent sorption of U onto the sediment surface. The column experiments provide an insight into humic colloid-mediated U migration in subsurface aquifers

  16. Inter renewal travelling wave reactor with rotary fuel columns

    International Nuclear Information System (INIS)

    Terai, Yuzo

    2016-01-01

    To realize the COP21 decision, this paper proposes Inter Renewal Travelling Wave Reactor that bear high burn-up rate 50% and product TRU fuel efficiently. The reactor is based on 4S Fast Reactor and has Reactor Fuel Columns as fuel assemblies that equalize temperature in the fuel assembly so that fewer structure is need to restrain thermal transformation. To equalize burn-up rate of all fuel assemblies in the reactor, each rotary fuel column has each motor-lifter. The rotary fuel column has two types (Cylinder type and Heat Pipe type using natrium at 15 kPa which supply high temperature energy for Ultra Super Critical power plant). At 4 years cycle all rotary fuel columns of the reactor are renewed by the metallurgy method (vacuum re-smelting) and TRU fuel is gotten from the water fuel. (author)

  17. Behavior of FRP-Confined Concrete-Filled Steel Tube Columns

    Directory of Open Access Journals (Sweden)

    Yiyan Lu

    2014-05-01

    Full Text Available This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP. Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap can effectively confine the concrete expansion and delay the local buckling of the steel tube. Both the load capacity and the axial deformation capacity of concrete-filled steel tube columns can be substantially enhanced with FRP confinement. A model is proposed to predict the load capacity of the FRP-confined concrete-filled steel tube columns. The predicted results are generally in good agreement with the experimental ones obtained in this study and in the literature.

  18. Effects of salts on protein-surface interactions: applications for column chromatography.

    Science.gov (United States)

    Tsumoto, Kouhei; Ejima, Daisuke; Senczuk, Anna M; Kita, Yoshiko; Arakawa, Tsutomu

    2007-07-01

    Development of protein pharmaceuticals depends on the availability of high quality proteins. Various column chromatographies are used to purify proteins and characterize the purity and properties of the proteins. Most column chromatographies require salts, whether inorganic or organic, for binding, elution or simply better recovery and resolution. The salts modulate affinity of the proteins for particular columns and nonspecific protein-protein or protein-surface interactions, depending on the type and concentration of the salts, in both specific and nonspecific manners. Salts also affect the binding capacity of the column, which determines the size of the column to be used. Binding capacity, whether equilibrium or dynamic (under an approximation of a slow flow rate), depends on the binding constant, protein concentration and the number of the binding site on the column as well as nonspecific binding. This review attempts to summarize the mechanism of the salt effects on binding affinity and capacity for various column chromatographies and on nonspecific protein-protein or protein-surface interactions. Understanding such salt effects should also be useful in preventing nonspecific protein binding to various containers. Copyright 2007 Wiley-Liss, Inc.

  19. Pulse transformer R and D for NLC klystron pulse modulator

    International Nuclear Information System (INIS)

    Akemoto, M.; Gold, S.; Krasnykh, A.; Koontz, R.

    1997-07-01

    The authors have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and requires a larger core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and a pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests using a klystron load are also presented

  20. Study on Predicting Axial Load Capacity of CFST Columns

    Science.gov (United States)

    Ravi Kumar, H.; Muthu, K. U.; Kumar, N. S.

    2017-11-01

    This work presents an analytical study and experimental study on the behaviour and ultimate load carrying capacity of axially compressed self-compacting concrete-filled steel tubular columns. Results of tests conducted by various researchers on 213 samples concrete-filled steel tubular columns are reported and present authors experimental data are reported. Two theoretical equations were derived for the prediction of the ultimate axial load strength of concrete-filled steel tubular columns. The results from prediction were compared with the experimental data. Validation to the experimental results was made.

  1. Partial Path Column Generation for the Vehicle Routing Problem

    DEFF Research Database (Denmark)

    Jepsen, Mads Kehlet; Petersen, Bjørn

    This paper presents a column generation algorithm for the Capacitated Vehicle Routing Problem (CVRP) and the Vehicle Routing Problem with Time Windows (VRPTW). Traditionally, column generation models of the CVRP and VRPTW have consisted of a Set Partitioning master problem with each column...... of the giant tour’; a so-called partial path, i.e., not necessarily starting and ending in the depot. This way, the length of the partial path can be bounded and a better control of the size of the solution space for the pricing problem can be obtained....

  2. SENSITIVITY ANALYSIS FOR SALTSTONE DISPOSAL UNIT COLUMN DEGRADATION ANALYSES

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G.

    2014-10-28

    PORFLOW related analyses supporting a Sensitivity Analysis for Saltstone Disposal Unit (SDU) column degradation were performed. Previous analyses, Flach and Taylor 2014, used a model in which the SDU columns degraded in a piecewise manner from the top and bottom simultaneously. The current analyses employs a model in which all pieces of the column degrade at the same time. Information was extracted from the analyses which may be useful in determining the distribution of Tc-99 in the various SDUs throughout time and in determining flow balances for the SDUs.

  3. Characterization of Bubble Size Distributions within a Bubble Column

    OpenAIRE

    Shahrouz Mohagheghian; Brian R. Elbing

    2018-01-01

    The current study experimentally examines bubble size distribution (BSD) within a bubble column and the associated characteristic length scales. Air was injected into a column of water via a single injection tube. The column diameter (63–102 mm), injection tube diameter (0.8–1.6 mm) and superficial gas velocity (1.4–55 mm/s) were varied. Large samples (up to 54,000 bubbles) of bubble sizes measured via 2D imaging were used to produce probability density functions (PDFs). The PDFs were used to...

  4. Random pulse generator

    International Nuclear Information System (INIS)

    Guo Ya'nan; Jin Dapeng; Zhao Dixin; Liu Zhen'an; Qiao Qiao; Chinese Academy of Sciences, Beijing

    2007-01-01

    Due to the randomness of radioactive decay and nuclear reaction, the signals from detectors are random in time. But normal pulse generator generates periodical pulses. To measure the performances of nuclear electronic devices under random inputs, a random generator is necessary. Types of random pulse generator are reviewed, 2 digital random pulse generators are introduced. (authors)

  5. Experimental and theoretical investigation of column - flat slab joint ductility

    International Nuclear Information System (INIS)

    Iskhakov, I.; Ribakov, Y.; Shah, A.

    2009-01-01

    Most modern seismic codes use ductility as one of the basic design parameters. Actually, ductility defines the ability of a structure or its elements to absorb energy by plastic deformations. Until the end of the previous century ductility was defined qualitatively. Most research works related to ductility are focused on structural elements' sections. This study was aimed at complex experimental and theoretical investigation of flat slab-column joints ductility. It is one of the first attempts to obtain quantitative values of joint's ductility for the case of high strength concrete columns and normal strength concrete slabs. It was shown that the flat slab-column joint is a three-dimension (3D) element and its ductility in horizontal and vertical directions are different. This is the main difference between ductility of elements and joint ductility. In case of flat slab-column joints, essential contribution to joint's ductility can be obtained due to the slab's confining effect. Based on experimental data, the authors demonstrate that flat slab-column joint's ductility depends on the joint's confining effect in two horizontal and vertical directions. Furthermore, the influence of slab load intensity and slab reinforcement ratio on the joint's ductility is performed in this study. It is also demonstrated that the effect of the ratio between the slab thickness and the column's section dimension on the ductility parameter is significant. Equations for obtaining a quantitative value of a flat slab-column joint's ductility parameter were developed.

  6. Practical column design guide

    CERN Document Server

    Nitsche, M

    2017-01-01

    This book highlights the aspects that need to be considered when designing distillation columns in practice. It discusses the influencing parameters as well as the equations governing them, and presents several numerical examples. The book is intended both for experienced designers and for those who are new to the subject.

  7. Computational analysis of ozonation in bubble columns

    International Nuclear Information System (INIS)

    Quinones-Bolanos, E.; Zhou, H.; Otten, L.

    2002-01-01

    This paper presents a new computational ozonation model based on the principle of computational fluid dynamics along with the kinetics of ozone decay and microbial inactivation to predict the performance of ozone disinfection in fine bubble columns. The model can be represented using a mixture two-phase flow model to simulate the hydrodynamics of the water flow and using two transport equations to track the concentration profiles of ozone and microorganisms along the height of the column, respectively. The applicability of this model was then demonstrated by comparing the simulated ozone concentrations with experimental measurements obtained from a pilot scale fine bubble column. One distinct advantage of this approach is that it does not require the prerequisite assumptions such as plug flow condition, perfect mixing, tanks-in-series, uniform radial or longitudinal dispersion in predicting the performance of disinfection contactors without carrying out expensive and tedious tracer studies. (author)

  8. Fiber Optical Parametric Chirped Pulse Amplification of Sub-Picosecond Pulses

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Da Ros, Francesco

    2013-01-01

    We demonstrate experimentally, for the first time to our knowledge, fiber optical parametric chirped pulse amplification of 400-fs pulses. The 400-fs signal is stretched, amplified by 26 dB and compressed back to 500 fs.......We demonstrate experimentally, for the first time to our knowledge, fiber optical parametric chirped pulse amplification of 400-fs pulses. The 400-fs signal is stretched, amplified by 26 dB and compressed back to 500 fs....

  9. Experimental analysis of reinforced concrete columns strengthened with Self-Compacting concrete

    Directory of Open Access Journals (Sweden)

    M. Y. M. Omar

    Full Text Available This paper presents the results of reinforced concrete columns strengthened by addition of a self-compacting concrete overlay at the compressed and at the tensioned face of the member, with and without addition of longitudinal steel bars. Eight columns were submit- ted to loading with an initial eccentricity of 60 mm . These columns had 120 mm x 250 mm of rectangular cross section, 2000 mm in length and four longitudinal reinforcement steel bars with 10 mm in diameter. Reference columns P1 and P2 were tested to failure without any type of rehabilitation. Columns P3 to P8 were loaded to a predefined load (close to the initial yield point of tension reinforce- ment, then unloaded and strengthened for a subsequent test until failure. Results showed that the method of rehabilitation used was effective, increasing the loading capacity of the strengthened pieces by 2 to 5 times the ultimate load of the reference column.

  10. Affinity-based screening of combinatorial libraries using automated, serial-column chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D.M.; Williams, K.P.; McGuinness, B. [PerSeptive Biosystems, Framingham, MA (United States)] [and others

    1996-04-01

    The authors have developed an automated serial chromatographic technique for screening a library of compounds based upon their relative affinity for a target molecule. A {open_quotes}target{close_quotes} column containing the immobilized target molecule is set in tandem with a reversed-phase column. A combinatorial peptide library is injected onto the target column. The target-bound peptides are eluted from the first column and transferred automatically to the reversed-phase column. The target-specific peptide peaks from the reversed-phase column are identified and sequenced. Using a monoclonal antibody (3E-7) against {beta}-endorphin as a target, we selected a single peptide with sequence YGGFL from approximately 5800 peptides present in a combinatorial library. We demonstrated the applicability of the technology towards selection of peptides with predetermined affinity for bacterial lipopolysaccharide (LPS, endotoxin). We expect that this technology will have broad applications for high throughput screening of chemical libraries or natural product extracts. 21 refs., 4 figs.

  11. Water Column Sonar Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The collection and analysis of water column sonar data is a relatively new avenue of research into the marine environment. Primary uses include assessing biological...

  12. Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.

    Science.gov (United States)

    Estabrook, Neil C; Corn, Jonathan B; Ewing, Marvene M; Cardenes, Higinia R; Das, Indra J

    2018-02-01

    Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer. Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively. Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed. CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.

  13. A simple, fast, and accurate thermodynamic-based approach for transfer and prediction of gas chromatography retention times between columns and instruments Part III: Retention time prediction on target column.

    Science.gov (United States)

    Hou, Siyuan; Stevenson, Keisean A J M; Harynuk, James J

    2018-03-27

    This is the third part of a three-part series of papers. In Part I, we presented a method for determining the actual effective geometry of a reference column as well as the thermodynamic-based parameters of a set of probe compounds in an in-house mixture. Part II introduced an approach for estimating the actual effective geometry of a target column by collecting retention data of the same mixture of probe compounds on the target column and using their thermodynamic parameters, acquired on the reference column, as a bridge between both systems. Part III, presented here, demonstrates the retention time transfer and prediction from the reference column to the target column using experimental data for a separate mixture of compounds. To predict the retention time of a new compound, we first estimate its thermodynamic-based parameters on the reference column (using geometric parameters determined previously). The compound's retention time on a second column (of previously determined geometry) is then predicted. The models and the associated optimization algorithms were tested using simulated and experimental data. The accuracy of predicted retention times shows that the proposed approach is simple, fast, and accurate for retention time transfer and prediction between gas chromatography columns. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Modeling of column apparatus processes

    CERN Document Server

    Boyadjiev, Christo; Boyadjiev, Boyan; Popova-Krumova, Petya

    2016-01-01

    This book presents a new approach for the modeling of chemical and interphase mass transfer processes in industrial column apparatuses, using convection-diffusion and average-concentration models. The convection-diffusion type models are used for a qualitative analysis of the processes and to assess the main, small and slight physical effects, and then reject the slight effects. As a result, the process mechanism can be identified. It also introduces average concentration models for quantitative analysis, which use the average values of the velocity and concentration over the cross-sectional area of the column. The new models are used to analyze different processes (simple and complex chemical reactions, absorption, adsorption and catalytic reactions), and make it possible to model the processes of gas purification with sulfur dioxide, which form the basis of several patents.

  15. Column experiments on organic micropollutants - applications and limitations

    Science.gov (United States)

    Banzhaf, Stefan; Hebig, Klaus

    2016-04-01

    As organic micropollutants become more and more ubiquitous in the aquatic environment, a sound understanding of their fate and transport behaviour is needed. This is to assure both safe and clean drinking water supply for mankind in the future and to protect the aquatic environment from pollution and negative consequences caused by manmade contamination. Apart from countless field studies, column experiments were and are frequently used to study transport of organic micropollutants. As the transport of (organic) solutes in groundwater is controlled by the chemical and physical properties of the compounds, the solvent (the groundwater including all solutes), and the substrate (the aquifer material), the adjustment and control of these boundary conditions allow to study a multitude of different experimental setups and to address specific research questions. The main purpose, however, remains to study the transport of a specific compound and its sorption and degradation behaviour in a specific sediment or substrate. Apart from the effective control of the individual boundary conditions, the main advantage of columns studies compared to other experimental setups (such as field studies, batch/microcosm studies), is that conservative and reactive solute breakthrough curves are obtained, which represent the sum of the transport processes. The analysis of these curves is well-developed and established. Additionally, limitations of this experimental method are presented here: the effects observed in column studies are often a result of dynamic, non-equilibrium processes. Time (or flow velocity) plays a major role in contrast to batch experiments, in which all processes will be observed until equilibrium is reached in the substrate-solution-system. Slightly modifying boundary conditions in different experiments have a strong influence on transport and degradation behaviour of organic micropollutants. This is a significant severe issue when it comes to general findings on the

  16. One stacked-column vibration test and analysis for VHTR core

    International Nuclear Information System (INIS)

    Ikushima, Takeshi; Ishizuka, Hiroshi; Ide, Akira; Hayakawa, Hitoshi; Shingai, Kazuteru.

    1978-07-01

    This paper describes experimental results of the vibration test on a single stacked-column and compares them with the analytical results. A 1/2 scale model of the core element of a very high temperature gas-cooled reactor (VHTR) was set on a shaking table. Sinusoidal waves, response time history waves, beat wave and step wave of input acceleration 100 - 900 gal in the frequency of 0.5 to 15 Hz were used to vibrate the table horizontally. Results are as follows: (1) The column has a non-linear resonance and exhibits a hysteresis response with jump points. (2) The column vibration characteristics is similar to that of the finite beams connected with non-linear soft spring. (3) The column resonance frequency decreases with increasing input acceleration. (4) The impact force increases with increasing input acceleration and boundary gap width. (5) Good correlation in vibration behavior of the stacked-column and impact force on the boundary between test and analysis was obtained. (auth.)

  17. Semi-automated 86Y purification using a three-column system

    International Nuclear Information System (INIS)

    Park, Luke S.; Szajek, Lawrence P.; Wong, Karen J.; Plascjak, Paul S.; Garmestani, Kayhan; Googins, Shawn; Eckelman, William C.; Carrasquillo, Jorge A.; Paik, Chang H.

    2004-01-01

    The separation of 86 Y from 86 Sr was optimized by a semi-automated purification system involving the passage of the target sample through three sequential columns. The target material was dissolved in 4 N HNO 3 and loaded onto a Sr-selective (Sr-Spec) column to retain the 86 Sr. The yttrium was eluted with 4 N HNO 3 onto the second Y-selective (RE-Spec) column with quantitative retention. The RE-Spec column was eluted with a stepwise decreasing concentration of HNO 3 to wash out potential metallic impurities to a waste container. The eluate was then pumped onto an Aminex A5 column with 0.1 N HCl and finally with 3 N HCl to collect the radioyttrium in 0.6-0.8 mL with a >80% recovery. This method enabled us to decontaminate Sr by 250,000 times and label 30 μ g of DOTA-Biotin with a >95% yield

  18. Uncertain Buckling Load and Reliability of Columns with Uncertain Properties

    DEFF Research Database (Denmark)

    Köylüoglu, H. U.; Nielsen, Søren R. K.; Cakmak, A. S.

    Continuous and finite element methods are utilized to determine the buckling load of columns with material and geometrical uncertainties considering deterministic, stochastic and interval models for the bending rigidity of columns. When the bending rigidity field is assumed to be deterministic, t....... for structural design, the lower bound is of crucial interest. The buckling load of fixed-free, simple-supported, pinned-fixed, fixed-fixed columns and a sample frame are calculated....

  19. Pulse-to-pulse variations in accreting X-ray pulsars

    Directory of Open Access Journals (Sweden)

    Kretschmar Peter

    2014-01-01

    Full Text Available In most accreting X-ray pulsars, the periodic signal is very clear and easily shows up as soon as data covering sufficient pulse periods (a few ten are available. The mean pulse profile is often quite typical for a given source and with minor variations repeated and recognisable across observations done years or even decades apart. At the time scale of individual pulses, significant pulse-to-pulse variations are commonly observed. While at low energies some of these variations might be explained by absorption, in the hard X-rays they will reflect changes in the accretion and subsequent emission. The amount of these variations appears to be quite different between sources and contains information about the surrounding material as well ass possibly interactions at the magnetosphere. We investigate such variations for a sample of well-known sources.

  20. Process for prevention of water build-up in cryogenic distillation column

    International Nuclear Information System (INIS)

    Hopewell, R.B.

    1988-01-01

    In a process for the separation of a hydrocarbon and acid gas containing feed stream in a cryogenic distillation column, a zone of the column which is operated at a temperature of 60 0 F or less, wherein free water accumulates or forms hydrates in the column from water vapor in the feed stream during the cryogenic process, and which process comprises separating the feed stream in the column into an overhead stream and a bottom stream, this patent describes the improvement which comprises: withdrawing a hydrocarbon and acid gas vapor stream which stream is enriched in water vapor with respect to the feed stream, thereby preventing the excess accumulation of free water or the formation of hydrates in the cryogenic column

  1. The dorsal tectal longitudinal column (TLCd): a second longitudinal column in the paramedian region of the midbrain tectum.

    Science.gov (United States)

    Aparicio, M-Auxiliadora; Saldaña, Enrique

    2014-03-01

    The tectal longitudinal column (TLC) is a longitudinally oriented, long and narrow nucleus that spans the paramedian region of the midbrain tectum of a large variety of mammals (Saldaña et al. in J Neurosci 27:13108-13116, 2007). Recent analysis of the organization of this region revealed another novel nucleus located immediately dorsal, and parallel, to the TLC. Because the name "tectal longitudinal column" also seems appropriate for this novel nucleus, we suggest the TLC described in 2007 be renamed the "ventral tectal longitudinal column (TLCv)", and the newly discovered nucleus termed the "dorsal tectal longitudinal column (TLCd)". This work represents the first characterization of the rat TLCd. A constellation of anatomical techniques was used to demonstrate that the TLCd differs from its surrounding structures (TLCv and superior colliculus) cytoarchitecturally, myeloarchitecturally, neurochemically and hodologically. The distinct expression of vesicular amino acid transporters suggests that TLCd neurons are GABAergic. The TLCd receives major projections from various areas of the cerebral cortex (secondary visual mediomedial area, and granular and dysgranular retrosplenial cortices) and from the medial pretectal nucleus. It densely innervates the ipsilateral lateral posterior and laterodorsal nuclei of the thalamus. Thus, the TLCd is connected with vision-related neural centers. The TLCd may be unique as it constitutes the only known nucleus made of GABAergic neurons dedicated to providing massive inhibition to higher order thalamic nuclei of a specific sensory modality.

  2. Pulse to pulse klystron diagnosis system

    International Nuclear Information System (INIS)

    Nowak, J.; Davidson, V.; Genova, L.; Johnson, R.; Reagan, D.

    1981-03-01

    This report describes a system used to study the behavior of SLAC high powered klystrons operating with a twice normal pulse width of 5 μs. At present, up to eight of the klystrons installed along the accelerator can be operated with long pulses and monitored by this system. The report will also discuss some of the recent findings and investigations

  3. Efficient chirped-pulse amplification of sub-20 fs laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Shinichi; Yamakawa, Koichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    We have developed a model for ultrabroadband and ultrashort pulse amplification including the effects of a pulse shaper for regenerative pulse shaping, gain narrowing and gain saturation in the amplifiers. Thin solid etalons are used to control both gain narrowing and gain saturation during amplification. This model has been used to design an optimized Ti:sapphire amplifier system for producing efficiently pulses of < 20-fs duration with approaching peak and average powers of 100 TW and 20 W. (author)

  4. Design concept of control system for cryogenic distillation columns of fusion reactor

    International Nuclear Information System (INIS)

    Yamanishi, Toshihiko; Okuno, Kenji

    1993-09-01

    Control systems were designed for cryogenic distillation columns in the main fuel cycle and the breeder blanket interface systems of fusion reactors. Three basic control modes were proposed for the column whose top product was more important; the column whose bottom product is more important; and the column having a feed back stream. The key component in the important product stream was selected for each column, and the analysis method for measurement of this key component was discussed. Some of the columns need the gas chromatography as the analysis instrument of the control system. The time required for the measurement of product purity by the gas chromatography considerably affects the stability of the control system. A significant conclusion is that permissible time is about 20 min. It is possible to complete the measurement within 20 minute by the gas chromatography. The gas chromatography is applicable for the control system of the column. (author)

  5. Patterns of digital volume pulse waveform and pulse transit time in ...

    African Journals Online (AJOL)

    In this study the digital volume pulse wave and the pulse transit time of the thumb and big toe were analyzed in young and older subjects some of whom were hypertensive. We aimed to study the components and patterns of the pulse waveform and the pulse transit time and how they might change. Material and Methods: ...

  6. Analysis of an industrial process simulator column using third-generation computed tomography

    International Nuclear Information System (INIS)

    Kirita, Rodrigo; Carvalho, Diego Vergacas de Sousa; Mesquita, Carlos Henrique de; Vasquez, Pablo Antonio S.; Hamada, Margarida Mizue

    2011-01-01

    The CT methodology must be tested using a simulator column in the laboratory before applying it in the industrial plants. In this work, using the third-generation industrial computed tomography developed at the IPEN, a gas absorption column, used as a simulator column for industrial process was evaluated. It is a glass cylindrical tube of 90 mm diameter and 1400 mm height constituted the following parts: random packed column, liquid circuit (water), gas circuit and analysis was used as a simulator column. Gamma ray tomography experiments were carried out, using this simulator column empty and filled with water. In this work the scanner was setting for 90 views and 19 projections for each detector totalizing 11970 projections. The resulting images describe the presence of liquid or gas phases and are possible to evaluate the linear attenuation coefficients inside the column. In this case, linear attenuation coefficient for water was 0.0813 cm-1. It was established that the newly developed third-generation fan-beam arrangement gamma scanner unit has a good spatial resolution acceptable given the size of the column used in this study. (author)

  7. Numerical Investigation of Slab-Column Connection by Finite Element Method

    International Nuclear Information System (INIS)

    Akram, T.; Shaikh, M.A.; Memon, A.A.

    2007-01-01

    The flat slab-on-column construction subjected to high transverse stresses concentrated at the slab-column connection can lead to a non-ductile, sudden and brittle punching failure and results in the accidental collapse of flat slab buildings. The major parameters affecting the slab-column connection are the concrete strength, slab thickness, slab reinforcement and aspect ratio of column. The application of numerical methods based on the finite element theory for solving practical tasks allow to perform virtual testing of structures and explore their behavior under load and other effects in different conditions taking into account the elastic and plastic behavior of materials, appearance and development of cracks and other damages (disintegrations), and finally to simulate the failure mechanism and its consequences. In this study, the models are developed to carry out the finite element analysis of slab- column connection using ADINA (Automatic Dynamic Incremental Nonlinear Analysis) by varying the slab thickness and slab confining reinforcement and to investigate their effect on the deflection and load carrying capacity. Test results indicate that by increasing the slab thickness, the deflection and the load carrying capacity of slab-column connection increases, more over, by increasing the slab confining reinforcement, the deflection decreases where as the load carrying capacity increases. (author)

  8. Precast Concrete Beam-to-Column Connection System

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Compared to conventional concrete constructions, precast concrete is a better option which is more cost-effective for production, transport, and erection when columns and beams can be fabricated independently. The BSF connection is a hidden beam and connection for gravity loads that eliminates the need for projecting column corbels. From a steel box cast into the concrete beam end, a sliding steel “knife” plate with a safety notch is cantilevered into a steel box that has been cast into the c...

  9. A 350 KV nanosecond pulse voltage generator with adjustable pulsed-width

    International Nuclear Information System (INIS)

    Wang, X.; Wang, M.; Chen, Y.Q.; Zeng, L.G.; Han, M.

    2002-01-01

    This paper presents a 350 kV nanosecond pulse voltage generator (NPVG). The voltage pulsed-width can be adjusted from 30 to 160 ns. The generator consists of: Marx generator, pulsed forming line (PFL), main switch and matched impedance. The output voltage of Marx generator is over than nU c (n- the stage number of Marx generator, U c -the charging voltage of capacitor). When the pulse forming line is terminated with an impedance that is over than the characteristic impedance of PFL, the higher voltage pulse was provided for the load

  10. Plant-wide control of coupled distillation columns with partial condensers

    International Nuclear Information System (INIS)

    Ebrahimzadeh, Edris; Baxter, Larry L.

    2016-01-01

    Highlights: • Extractive distillation system for CO_2–ethane azeotrope separation. • Control of distillation column systems that have interconnected partial condenser and total condenser columns. • Single-end temperature control of distillation columns. • Aspen Dynamics tools applied for rigorous steady-state and dynamic simulations. - Abstract: Conventional distillation control processes use vapor distillate flowrate to control column pressure and condenser heat removal to control the reflux drum level. These intuitive control systems work well for isolated columns or columns with total condensers. However, these controls are not effective when columns with partial condensers occur in series. The pressure and reflux drum level interact in such systems in ways that defeat conventional control systems, rendering them unable to maintain product purities in the presence of large feed flowrate and composition disturbances. This investigation documents a plant-wide control structure that can address this issue by controlling pressure through reflux heat removal rate and reflux drum level by reflux flow rate. This control system demonstrates its capability to handle large disturbances in throughput and feed composition through a series of Aspen simulations. This alternative system is no more complicated than the conventional system and should work on distillation columns of nearly all designs, not just the coupled partial condenser designs for which it is essential. Common natural gas processing provides a specific example of this alternative control system. Natural gas commonly includes high concentrations of CO_2 that must be removed prior to pipeline or LNG distribution. The existence of a minimum-boiling temperature azeotrope between ethane, virtually always present in natural gas, and carbon dioxide complicates the separation of CO_2 from the hydrocarbons. This separation commonly employs extractive distillation with high-molecular-weight hydrocarbons. Our

  11. Thermodynamic evaluation of distillation columns using exergy loss profiles: a case study on the crude oil atmospheric distillation column

    Energy Technology Data Exchange (ETDEWEB)

    Tarighaleslami, Amir Hossein [Mahshahr Branch, Islamic Azad University, Chemical Engineering Faculty, Mahshar, Khouzestan (Iran, Islamic Republic of); Omidkhah, Mohammad Reza [Tarbiat Modares University, Chemical Engineering Department, Faculty of Engineering, Tehran (Iran, Islamic Republic of); Ghannadzadeh, Ali [University of Toulouse, Department of Process and System Engineering, Chemical Engineering Laboratory, Toulouse (France); Hoseinzadeh Hesas, Roozbeh [University of Malaya, Chemical Engineering Department, Faculty of Engineering, Kuala Lumpur (Malaysia)

    2012-06-15

    This paper presents a case study on the crude oil atmospheric distillation column of Tabriz refinery plant to show the applicability of exergy loss profiles in thermodynamic examination of the different retrofit options. The atmospheric distillation column of Tabriz refinery has been revamped as a consequence of increase of the plant capacity to 100,000 bpd. To cover the deficit of feedstock of the revamped unit, a blend of the existing feedstock with imported crude oil is used as a feedstock. However, to investigate how the blend of these two different types of crudes as a feedstock has an influence on the operating conditions, the examination of the column is needed. Exergy as a comprehensive thermodynamic property which translates the temperature, pressure and composition change into a common unit has been chosen to evaluate the distillation column thermodynamically. Furthermore, the exergy loss profile of the base case serves as a scoping tool to pinpoint the source of inefficiencies. Then, the exergy loss profile as a screening tool has found the retrofit options which are likely to yield greatest energy saving from a list of retrofit options proposed by the industrial partner. In the presented case study, the exergy loss profile identifies the best retrofit option with 17.16% reduction in exergy losses, which finally lead to 3.6% reduction of primary fuel demand. (orig.)

  12. Circular Raft Footings Strengthened by Stone Columns under Static Loads

    OpenAIRE

    R. Ziaie Moayed; B. Mohammadi-Haji

    2016-01-01

    Stone columns have been widely employed to improve the load-settlement characteristics of soft soils. The results of two small scale displacement control loading tests on stone columns were used in order to validate numerical finite element simulations. Additionally, a series of numerical calculations of static loading have been performed on strengthened raft footing to investigate the effects of using stone columns on bearing capacity of footings. The bearing capacity of single and group of ...

  13. Estimation of RC slab-column joints effective strength using neural networks

    Directory of Open Access Journals (Sweden)

    A. A. Shah

    Full Text Available The nominal strength of slab-column joints made of highstrength concrete (HSC columns and normal strength concrete (NSC slabs is of great importance in structural design and construction of concrete buildings. This topic has been intensively studied during the last decades. Different types of column-slab joints have been investigated experimentally providing a basis for developing design provisions. However, available data does not cover all classes of concretes, reinforcements, and possible loading cases for the proper calculation of joint stresses necessary for design purposes. New numerical methods based on modern software seem to be effective and may allow reliable prediction of column-slab joint strength. The current research is focused on analysis of available experimental data on different slab-to-column joints with the aim of predicting the nominal strength of slabcolumn joint. Neural networks technique is proposed herein using MATLAB routines developed to analyze available experimental data. The obtained results allow prediction of the effective strength of column-slab joints with accuracy and good correlation coefficients when compared to regression based models. The proposed method enables the user to predict the effective design of column-slab joints without the need for conservative safety coefficients generally promoted and used by most construction codes.

  14. Mathematical simulation of column flotation in pilot scale

    International Nuclear Information System (INIS)

    Simpson, J.; Jordan, D.; Cifuentes, G.; Morales, A.; Briones, L.

    2010-01-01

    The Procemin-I area of the Centro Minero Metalurgico Tecnologia y Servicio (CIMM T and S), has a full milling and flotation pilot plant in which several experiences are developed as: optimization of circuits, plant design, procurement of operating parameters, etc. Ones of the equipment in operation is the column flotation to pilot scale, witch have a medium level of automation. The problem presented in the operation of the column flotation is the low relationship during the operation between the operating basis parameters and the metallurgical results. The mathematical models used today to estimate the metallurgical results (i.e.: concentrate, tailing, enrichment and recovery) depending on variables that are manipulated by hand according the operator experience. But the process engineer needs tools without subjective vision to obtain the best performance of the column. The method used to help the column operation was a mathematical model based on the Stepwise Regression then considering empirical relationships between operational variables and experimental results. All the mathematical relationship developed in this study have a good correlation (up 90 % of precision), except one (up 70 %) due by non regular mineralogical feed. (Author) 7 refs.

  15. Design and control of integrated chromatography column sequences.

    Science.gov (United States)

    Andersson, Niklas; Löfgren, Anton; Olofsson, Marianne; Sellberg, Anton; Nilsson, Bernt; Tiainen, Peter

    2017-07-01

    To increase the productivity in biopharmaceutical production, a natural step is to introduce integrated continuous biomanufacturing which leads to fewer buffer and storage tanks, smaller sizes of integrated unit operations, and full automation of the operation. The main contribution of this work is to illustrate a methodology for design and control of a downstream process based on integrated column sequences. For small scale production, for example, pre-clinical studies, integrated column sequences can be implemented on a single chromatography system. This makes for a very efficient drug development platform. The proposed methodology is composed of four steps and is governed by a set of tools, that is presented, that makes the transition from batch separations to a complete integrated separation sequence as easy as possible. This methodology, its associated tools and the physical implementation is presented and illustrated on a case study where the target protein is separated from impurities through an integrated four column sequence. This article shows that the design and control of an integrated column sequence was successfully implemented for a tertiary protein separation problem. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:923-930, 2017. © 2017 American Institute of Chemical Engineers.

  16. IMPLEMENTATION OF COLUMN-ORIENTED DATABASE IN POSTGRESQL FOR OPTIMIZATION OF READ-ONLY QUERIES

    OpenAIRE

    Aditi D. Andurkar

    2012-01-01

    The era of column-oriented database systems has truly begun with open source database systems like C-Store, MonetDb, LucidDb and commercial ones like Vertica. Column-oriented database stores data column-by-column which means it stores information of single attribute collectively. The need for Column-oriented database arose from the need of business intelligence for efficient decision making where traditional row-oriented database gives poor performance. PostgreSql is an open so...

  17. Locating karst depressed columns by means of Rn measurement on the surface

    International Nuclear Information System (INIS)

    Tang Daimao; Liu Hongfu; Duan Hongjie; Duan Lindi; Sui Haichen

    1999-01-01

    The coal mining and the related surface projects are extremely harassed by the underground karst depressed columns. The author discussed the surface Rn concentration's abnormality caused by the karst depressed columns. It is concluded that different kinds of karst depressed column can cause different Rn concentration's abnormality. The α-cup Rn measuring instrument was used for detecting Rn abnormality on the surface in order to locate the underground karst depressed columns

  18. A development of super computed tomography scanner for industrial column investigation

    International Nuclear Information System (INIS)

    Abdul Quddoos Abu Bakar; Jaafar Abdullah; Ismail Mustapha

    2004-01-01

    Computed Tomography (CT) scanner is a desired devices on create images of internal structure of unrecognized object. The formation of a CT images is a distinct three phase process. The scanning phase produces data, but not an image. Then, reconstruction phase processes the acquired data and forms a digital image. The visible and displayed analog image is produced by the digital to analog conversation phase. In this case, there are adjustable factors associated with each of these phases that can have an effect on the characteristics and quantity of the image. In term on this project of column scanning, during the scanning phase a fan-shaped gamma ray beam is scanned around the column. The amount of gamma radiation that penetrates the column along each individual ray (pathway) through the column is measured by the detectors that intercept the gamma ray beam after it passes through the column.This project of Super Computed Tomography (CT) is develop to reconstruct and redesign the mechanical parts and equipment to suits the purpose of the industrial column investigation in the region. (Author)

  19. Calcium Isotope Analysis with "Peak Cut" Method on Column Chemistry

    Science.gov (United States)

    Zhu, H.; Zhang, Z.; Liu, F.; Li, X.

    2017-12-01

    To eliminate isobaric interferences from elemental and molecular isobars (e.g., 40K+, 48Ti+, 88Sr2+, 24Mg16O+, 27Al16O+) on Ca isotopes during mass determination, samples should be purified through ion-exchange column chemistry before analysis. However, large Ca isotopic fractionation has been observed during column chemistry (Russell and Papanastassiou, 1978; Zhu et al., 2016). Therefore, full recovery during column chemistry is greatly needed, otherwise uncertainties would be caused by poor recovery (Zhu et al., 2016). Generally, matrix effects could be enhanced by full recovery, as other elements might overlap with Ca cut during column chemistry. Matrix effects and full recovery are difficult to balance and both need to be considered for high-precision analysis of stable Ca isotopes. Here, we investigate the influence of poor recovery on δ44/40Ca using TIMS with the double spike technique. The δ44/40Ca values of IAPSO seawater, ML3B-G and BHVO-2 in different Ca subcats (e.g., 0-20, 20-40, 40-60, 60-80, 80-100%) with 20% Ca recovery on column chemistry display limited variation after correction by the 42Ca-43Ca double spike technique with the exponential law. Notably, δ44/40Ca of each Ca subcut is quite consistent with δ44/40Ca of Ca cut with full recovery within error. Our results indicate that the 42Ca-43Ca double spike technique can simultaneously correct both of the Ca isotopic fractionation that occurred during column chemistry and thermal ionization mass spectrometry (TIMS) determination properly, because both of the isotopic fractionation occurred during analysis follow the exponential law well. Therefore, we propose the "peak cut" method on Ca column chemistry for samples with complex matrix effects. Briefly, for samples with low Ca contents, we can add the double spike before column chemistry, and only collect the middle of the Ca eluate and abandon the both sides of Ca eluate that might overlap with other elements (e.g., K, Sr). This method would

  20. Study of column construction and tritium inventory of cryogenic distillation columns for tritium plant of a fusion reactor

    International Nuclear Information System (INIS)

    Iwai, Yasunori; Yamanishi, Toshihiko; Okuno, Kenji

    1996-11-01

    Cryogenic distillation column system is believed to be best for large throughput of hydrogen isotope separation. The major disadvantage of the system is a large tritium inventory in liquid phase. From a viewpoint of safety of a fusion reactor, it is important to establish the design method of minimized the tritium inventory. Anumerical study to investigate the possible design improvement to reduce inventory while maintaining separation performance was conducted. The design conditions are based on ITER DDD report, and details are as follows, 1) Exhaust stream with less than 50 Ci/y loss of tritium, 2) 99.9% purity D2, and 3) 90% purity T2. 4) total inventory with less than 100g. In the design of ITER to process 32 mol/hr, 4 columns (3 of 4 columns make closed loop) are best and total inventory is 94g. Particularly recent design of ITER to process 320 mol/hr requires additional efforts to minimize the inventory. The simulation also suggests it is effective to reduce inventory to draw two different purity product streams. (author)

  1. Monitoring aged reversed-phase high performance liquid chromatography columns

    NARCIS (Netherlands)

    Bolck, A; Smilde, AK; Bruins, CHP

    1999-01-01

    In this paper, a new approach for the quality assessment of routinely used reversed-phase high performance liquid chromatography columns is presented. A used column is not directly considered deteriorated when changes in retention occur. If attention is paid to the type and magnitude of the changes,

  2. A cryogenic distillation column cascade for a fusion reactor

    International Nuclear Information System (INIS)

    Kinoshita, M.

    1984-01-01

    A cryogenic distillation column cascade composed of only two columns is proposed. Compared with the Tritium Systems Test Assembly (TSTA) cascade, the tritium inventory is about 1.5 times more and the packed height of the highest column increases by about 40%. However, the number of the columns is halved with the separation performance unchanged. The number of the instruments needed and the number of the process parameters to be monitored are also reduced. Unlike in the case of the TSTA cascade, the performance of the proposed cascade is not subject to the flow rate of the neutral beam injector recycle stream. The high performance can be maintained even if the protium percentage in the raw fuel input increases significantly (e.g., from 1 to 3%), just by adjusting the flow rates of the top, bottom, and side streams. Because of this great flexibility, it is worthwhile to build and study the proposed cascade as a possible alternative to the TSTA cascade

  3. Associations between the Cervical Vertebral Column and Craniofacial Morphology

    DEFF Research Database (Denmark)

    Sonnesen, Ane Liselotte

    2010-01-01

    Aim. To summarize recent studies on morphological deviations of the cervical vertebral column and associations with craniofacial morphology and head posture in nonsyndromic patients and in patients with obstructive sleep apnoea (OSA). Design. In these recent studies, visual assessment of the cerv......Aim. To summarize recent studies on morphological deviations of the cervical vertebral column and associations with craniofacial morphology and head posture in nonsyndromic patients and in patients with obstructive sleep apnoea (OSA). Design. In these recent studies, visual assessment...... of the cervical vertebral column and cephalometric analysis of the craniofacial skeleton were performed on profile radiographs of subjects with neutral occlusion, patients with severe skeletal malocclusions and patients with OSA. Material from human triploid foetuses and mouse embryos was analysed histologically....... Results. Recent studies have documented associations between fusion of the cervical vertebral column and craniofacial morphology, including head posture in patients with severe skeletal malocclusions. Histological studies on prenatal material supported these findings. Conclusion. It is suggested...

  4. [Column chromatography purification and analysis of biodiesel by transesterification].

    Science.gov (United States)

    Liu, Yang; Yi, Huai-feng; Chen, Yu; Wu, Yu-long; Yang, Ming-de; Chen, Zeng; Tong, Jun-mao

    2012-02-01

    In the present paper, crude biodiesel prepared with sorbifolia oil as raw material by transesterification was purified by column chromatography, then the composition of biodiesel was analyzed by gas chromatography, FTIR, GC-MS and 1H NMR. Column chromatography can separate the crude biodiesel into two fractions: petroleum ether eluted fraction (A1) and methanol eluted fraction (A2). Petroleum ether eluted fraction was mainly biodiesel fraction, which was produced from sorbifolia oil by transesterification, including methyl linoleate, methyl cis-9-octadecenoate and so on; methanol eluted fraction was mainly glycerol fraction, which came from the side reaction of transesterification. The results show that the purity of refined biodiesel increased from 77.51% to 93.872, and the product recovery rate reached up to 91.04% after the purification by column chromatography. The results obtained by FTIR and 1H NMR further showed that the column chromatography can effectively improve the purity of biodiesel. This paper provides a basis for industrialization of purification of biodiesel.

  5. Simultaneous determination of palladium, platinum and rhodium by on-line column enrichment and HPLC with 2,4-dihydroxybenzylidenethiorhodanine as pre-column derivatization reagent

    Directory of Open Access Journals (Sweden)

    Dong Xuechang

    2006-01-01

    Full Text Available A new method for the simultaneous determination of palladium, platinum and rhodium ions as metal-DHBTR chelates was developed. The palladium, platinum and rhodium ions were pre-column derivatized with 2,4-dihydroxybenzylidenethiorhodanine (DHBTR to form colored chelates. The Pd-DHBTR, Pt-DHBTR and Rh-DHBTR chelates can be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column with a 0.05 mol L-1 sodium acetate-acetic acid buffer solution (pH 3.5 as mobile phase. After the enrichment had finished, by switching the six ports switching valve, the retained chelates were back-flushed by mobile phase and traveling towards the analytical column. These chelates separation on the analytical column was satisfactory with 62% (v/v acetonitrile (containing 0.05 mol L-1 of pH 3.5 sodium acetate-acetic acid buffer salt and 0.1% (m/v of tritonX-100 as mobile phase. The Limits of detection of palladium, platinum and rhodium are 3.6 ng L-1, 3.2 ng L-1 and 4.5 ng L-1, respectively. This method was applied to the determination of palladium, platinum and rhodium in water, urine and soil samples with good results.

  6. Optical pulse compression

    International Nuclear Information System (INIS)

    Glass, A.J.

    1975-01-01

    The interest in using large lasers to achieve a very short and intense pulse for generating fusion plasma has provided a strong impetus to reexamine the possibilities of optical pulse compression at high energy. Pulse compression allows one to generate pulses of long duration (minimizing damage problems) and subsequently compress optical pulses to achieve the short pulse duration required for specific applications. The ideal device for carrying out this program has not been developed. Of the two approaches considered, the Gires--Tournois approach is limited by the fact that the bandwidth and compression are intimately related, so that the group delay dispersion times the square of the bandwidth is about unity for all simple Gires--Tournois interferometers. The Treacy grating pair does not suffer from this limitation, but is inefficient because diffraction generally occurs in several orders and is limited by the problem of optical damage to the grating surfaces themselves. Nonlinear and parametric processes were explored. Some pulse compression was achieved by these techniques; however, they are generally difficult to control and are not very efficient. (U.S.)

  7. ADAM28 localizes to HLA-G+ trophoblasts and promotes column cell outgrowth.

    Science.gov (United States)

    De Luca, L C; Le, H T; Mara, D L; Beristain, A G

    2017-07-01

    Trophoblast progenitor cell differentiation towards the extravillous trophoblast (EVT) lineage initiates within proximal regions of anchoring columns of first trimester placental villi. While molecular processes controlling the initial stages of progenitor cell differentiation along the EVT pathway have been described, much remains unknown about factors important in distal column cell differentiation into invasive EVTs. ADAMs are proteases that regulate growth factor signaling, cell-matrix adhesion, and matrix proteolysis, and thus impact many processes relevant in placentation. Global gene expression studies identified the ADAM subtype, ADAM28, to be highly expressed in EVT-like trophoblasts, suggesting that it may play a role in EVT function. This study aims to test the functional importance of ADAM28 in column cell outgrowth and maintenance. ADAM28 mRNA levels and protein localization were determined by qPCR and immunofluorescence microscopy analyses in purified placental villi cell populations and tissues. ADAM28 function in trophoblast column outgrowth was examined using ADAM28-targetting siRNAs in Matrigel-imbedded placental explant cultures. Within placental villi, ADAM28 mRNA levels were highest in HLA-G + column trophoblasts, and consistent with this, ADAM28 was preferentially localized to HLA-G + trophoblasts within distal anchoring columns and decidual tissue. siRNA-directed loss of ADAM28 impaired trophoblast column outgrowth and resulted in increased apoptosis in matrix-invading trophoblasts. Our findings suggest that ADAM28 promotes column outgrowth by providing survival cues within anchoring column cells. This study also provides insight into a possible role for ADAM28 in driving differentiation of column trophoblasts into invasive HLA-G + EVT subsets. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Numerical analysis and optimisation of heavy water upgrading column

    International Nuclear Information System (INIS)

    Sankar, Rama; Ghosh, Brindaban; Bhanja, K.

    2013-01-01

    In the 'Pressurised Heavy Water' type of reactors, heavy water is used both as moderator and coolant. During operation of reactor downgraded heavy water is generated that needs to be upgraded for reuse in the reactor. When the isotopic purity of heavy water becomes less than 99.75%, it is termed as downgraded heavy water. Downgraded heavy water also contains impurity such as corrosion products, dirt, oil etc. Upgradation of downgraded heavy water is normally done in two steps: (i) Purification: In this step downgraded heavy water is first purified to remove corrosion products, dirt, oil, etc. and (ii) Upgradation of heavy water to increase its isotopic purity, this step is carried out by vacuum distillation of downgraded heavy water after purification. This project is aimed at mathematical modelling and numerical simulation of heavy water upgrading column. Modelling and simulation studies of the upgradation column are based on equilibrium stage model to evaluate the effect of feed location, pressure, feed composition, reflux ratio in the packed column for given reboiler and condenser duty of distillation column. State to stage modelling of two-phase two-component flow has constitutes the overall modelling of the column. The governing equations consist of stage-wise species and overall mass continuity and stage-wise energy balance. This results in tridigonal matrix equation for stage liquid fractions for heavy and light water. The stage-wise liquid flow rates and temperatures are governed by stage-wise mass and energy balance. The combined form of the corresponding governing equations, with the incorporation of thermodynamic equation of states, form a system of nonlinear equations. This system have been resolved numerically using modified Newton-Raphson method. A code in the MATLAB platform has been developed by on above numerical procedure. The optimisation of the column operating conditions is to be carried out based on parametric studies and analysis of different

  9. Experimental engineering section off-gas decontamination facility's fractionator column: installation and performance

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Fowler, V.L.; Inman, D.J.

    1978-03-01

    A detailed description of the third column recently installed in the Experimental Engineering Section Off-Gas Decontamination Facility (EES-ODF) is presented. The EES-ODF is being used to provide engineering-scale experiments (nominal gas and liquid flows of 5 scfm and 0.5 gpm, respectively) in the development of the Krypton Absorption in Liquid CO 2 (KALC) process. A detailed discussion of the column's construction is provided. This discussion includes the peripherals associated with the column, such as refrigeration, heat exchangers, instrumentation, etc. The compressibility of Goodloe packing (the packing in the other columns) and the possible reduced throughput due to this compression have revealed the desirablility of a random (i.e., noncompressible) packing. Toward this end, the third column is packed with a new random packing (PRO-PAK). A preliminary comparison between this packing and the woven wire mesh packing (Goodloe) used in the other two columns has been made. Experiments comparing the throughput capacity indicate that the PRO-PAK packing has approximately 60% the capacity of Goodloe for a CO 2 system. When used as a fractionator or stripper with the basic O 2 -Kr-CO 2 KALC system, the PRO-PAK column produced HTU values less than or equal to the GOODLOE columns under similar operating conditions

  10. Modeling of high-strength concrete-filled FRP tube columns under cyclic load

    Science.gov (United States)

    Ong, Kee-Yen; Ma, Chau-Khun; Apandi, Nazirah Mohd; Awang, Abdullah Zawawi; Omar, Wahid

    2018-05-01

    The behavior of high-strength concrete (HSC) - filled fiber-reinforced-polymer (FRP) tubes (HSCFFTs) column subjected to cyclic lateral loading is presented in this paper. As the experimental study is costly and time consuming, a finite element analysis (FEA) is chosen for the study. Most of the previous studies have focused on examining the axial load behavior of HSCFFT column instead of seismic behavior. The seismic behavior of HSCFFT columns has been the main interest in the industry. The key objective of this research is to develop a reliable numerical non-linear FEA model to represent the seismic behavior of such column. A FEA model was developed using the Concrete Damaged Plasticity Model (CDPM) available in the finite element software package (ABAQUS). Comparisons between experimental results from previous research and the predicted results were made based on load versus displacement relationships and ultimate strength of the column. The results showed that the column increased in ductility and able to deform to a greater extent with the increase of the FRP confinement ratio. With the increase of confinement ratio, HSCFFT column achieved a higher moment resistance, thus indicated a higher failure strength in the column under cyclic lateral load. It was found that the proposed FEA model can regenerate the experimental results with adequate accuracy.

  11. Pulse induction heating

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A S; Kachanov, B Y; Kogan, B V

    1993-12-31

    Induction heating and three types of pulse processes were studied. It was found that in pulse processes the frequency and pulse duration of heat treatments do not remain constant. High frequency pulse heat treatments can be used on sprayed coatings; such treatments will result in stronger surfaces with no cracks. For induction hardening, the rate of specific power was 1 to 1.5 kW/sq.cm, for forging it was 0.2 to 0.3 kW/sq.cm and for melting it was 0.05 to 0.1 kW/sq.cm. The application of pulse heating will result in higher rates of specific power.

  12. Gravity Effects on the Free Vibration of a Graphite Column

    International Nuclear Information System (INIS)

    Ki, Dong-Ok; Kim, Jong-Bum; Park, Keun-Bae; Lee, Won-Jae

    2006-01-01

    The gravity effects on the free vibration of a graphite column are studied. Graphite block is a key component of a HTGR (High Temperature Gas Cooled Reactor). The major core elements, such as the fuel blocks and neutron reflector blocks, of HTTR (High Temperature Test Reactor, Japan) and GT-MHR (Gas Turbine- Modular Helium Reactor, USA) consist of stacked hexagonal graphite blocks forming a group of columns. The vibration of the columns induced by earthquakes may lead to solid impacts between graphite blocks and structural integrity problems. The study of free vibration characteristics of the graphite block column is the first step in the core internal structure dynamic analysis. Gravity force bring a negative stiffness term to the transverse vibration analysis of heavy long column structures, and results in natural frequency reductions. Generally it is not considered in the not so tall structure cases, because the gravity term makes the analysis and design complicated. Therefore it is important to check whether the gravity effect is severe or not

  13. Towards Reconstructing a Doric Column in a Virtual Construction Site

    Science.gov (United States)

    Bartzis, D.

    2017-02-01

    This paper deals with the 3D reconstruction of ancient Greek architectural members, especially with the element of the Doric column. The case study for this project is the Choragic monument of Nicias on the South Slope of the Athenian Acropolis, from which a column drum, two capitals and smaller fragments are preserved. The first goal of this paper is to present some benefits of using 3D reconstruction methods not only in documentation but also in understanding of ancient Greek architectural members. The second goal is to take advantage of the produced point clouds. By using the Cloud Compare software, comparisons are made between the actual architectural members and an "ideal" point cloud of the whole column in its original form. Seeking for probable overlaps between the two point clouds could assist in estimating the original position of each member/fragment on the column. This method is expanded with more comparisons between the reference column model and other members/fragments around the Acropolis, which may have not yet been ascribed to the monument of Nicias.

  14. Column selectivity in reversed-phase liquid chromatography I. A general quantitative relationship.

    Science.gov (United States)

    Wilson, N S; Nelson, M D; Dolan, J W; Snyder, L R; Wolcott, R G; Carr, P W

    2002-07-05

    Retention factors k have been measured for 67 neutral, acidic and basic solutes of highly diverse molecular structure (size, shape, polarity, hydrogen bonding, pKa, etc.) on 10 different C18 columns (other conditions constant). These data have been combined with k values from a previous study (86 solutes, five different C8 and C18 columns) to develop a six-term equation for the correlation of retention as a function of solute and column. Values of k can be correlated with an accuracy of +/- 1-2% (1 standard deviation). This suggests that all significant contributions to column selectivity have been identified (and can be measured) for individual alkyl-silica columns which do not have an embedded polar group. That is, columns of the latter kind can be quantitatively characterized in terms of selectivity for use in the separation of any sample.

  15. Pulse-shaping mechanism in colliding-pulse mode-locked laser diodes

    DEFF Research Database (Denmark)

    Bischoff, Svend; Sørensen, Mads Peter; Mørk, J.

    1995-01-01

    The large signal dynamics of passively colliding pulse mode-locked laser diodes is studied. We derive a model which explains modelocking via the interplay of gain and loss dynamics; no bandwidth limiting element is necessary for pulse formation. It is found necessary to have both fast and slow...... absorber dynamics to achieve mode-locking. Significant chirp is predicted for pulses emitted from long lasers, in agreement with experiment. The pulse width shows a strong dependence on both cavity and saturable absorber length. (C) 1995 American Institute of Physics....

  16. HETP evaluation of structured packing distillation column

    Directory of Open Access Journals (Sweden)

    A. E. Orlando Jr.

    2009-09-01

    Full Text Available Several tests with a hydrocarbon mixture of known composition (C8-C14, obtained from DETEN Chemistry S.A., have been performed in a laboratory distillation column, having 40mm of nominal diameter and 2.2m high, with internals of Sulzer DX gauze stainless steel structured packing. The main purpose of this work was to evaluate HETP of a structured packing laboratory scale distillation column, operating continuously. Six HETP correlations available in the literature were compared in order to find out which is the most appropriate for structured packing columns working with medium distillates. Prior to the experimental tests, simulation studies using commercial software PRO/II® were performed in order to establish the optimum operational conditions for the distillation, especially concerning operating pressure, top and bottom temperatures, feed location and reflux ratio. The results of PRO/II® were very similar to the analysis of the products obtained during continuous operation, therefore permitting the use of the properties calculated by that software on the theoretical models investigated. The theoretical models chosen for HETP evaluation were: Bravo, Rocha and Fair (1985; Rocha, Bravo and Fair (1993, 1996; Brunazzi and Pagliant (1997; Carlo, Olujić and Pagliant (2006; Olujić et al., (2004. Modifications concerning calculation of specific areas were performed on the correlations in order to fit them for gauze packing HETP evaluation. As the laboratory distillation column was operated continuously, different HETP values were found by the models investigated for each section of the column. The low liquid flow rates in the top section of the column are a source of error for HETP evaluation by the models; therefore, more reliable HETP values were found in the bottom section, in which liquid flow rates were much greater. Among the theoretical models, Olujić et al. (2004 has shown good results relative to the experimental tests. In addition, the

  17. Water column methanotrophy controlled by a rapid oceanographic switch

    NARCIS (Netherlands)

    Steinle, L.; Graves, C.A.; Treude, T.; Ferré, B.; Biastoch, A.; Bussmann, I.; Berndt, C.; Krastel, S.; James, R.H.; Behrens, E.; Böning, C.W.; Greinert, J.; Sapart, C.-J.; Scheinert, M.; Sommer, S.; Lehmann, M.F.; Niemann, H.

    2015-01-01

    From the seabed to the water column, where it may be consumed by aerobic methanotrophic bacteria. The size and activity of methanotrophic communities, which determine the amount of methane consumed in the water column,are thought to be mainly controlled by nutrient and redoxdynamics3–7. Here, we

  18. Thermal Analysis for Ion-Exchange Column System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Si Y.; King, William D.

    2012-12-20

    Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models were used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.

  19. S100 lathe bed pulse generator applied to pulsed nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Cernicchiaro, G.R.C.; Rudge, M.G.; Albuquerque, M.P.

    1989-01-01

    The project and construction of four channel pulse generator in the S100 standard plate and its control software for microcomputer are described. The microcomputer has total control on the pulse generator, which has seven programable parameters, defining the position of four pulses and the width for the three first ones. This pulse generator is controlled by a software developed in c language, and is used in pulsed nuclear magnetic resonance experiences. (M.C.K.) [pt

  20. Safety operation of chromatography column system with discharging hydrogen radiolytically generated

    International Nuclear Information System (INIS)

    Watanabe, S; Sano, Y.; Nomura, K.; Koma, Y.; Okamoto, Y.

    2015-01-01

    The extraction chromatography technology is one of the promising methods for the partitioning of minor actinides (Am and Cm) from spent nuclear fuels. In the extraction chromatography system, the accumulation of hydrogen gas in the chromatography column is suspected to lead to fire or explosion. In order to prevent hazardous accidents, it is necessary to evaluate behaviors of gas radiolytically generated inside the column. In this study, behaviors of gas inside the extraction chromatography column were investigated through experiments and Computation Fluid Dynamics (CFD) simulation. N_2 gas once accumulated as bubbles in the packed bed was hardly discharged by the flow of mobile phase. However, the CFD simulation and X-ray imaging on γ-ray irradiated column revealed that during operation the hydrogen gas generated in the column was dissolved into the mobile phase without accumulation and then discharged. (authors)

  1. Cost and Ductility Effectiveness of Concrete Columns Strengthened with CFRP and SFRP Sheets

    Directory of Open Access Journals (Sweden)

    Khaled Abdelrahman

    2014-05-01

    Full Text Available Recently, steel fibre reinforced polymers (SFRP sheets have been introduced for the repair and rehabilitation of concrete structures. Few researchers studied the behaviour of the concrete columns wrapped with SFRP sheets; however, several critical parameters such as the cost and ductility effectiveness of the SFRP wrapped concrete columns have been lightly addressed. Thus, the main objective of this paper is to study the cost and ductility effectiveness of SFRP wrapped concrete columns and compare the results with the conventionally used carbon FRP (CFRP wrapped concrete columns. In addition, an analytical procedure to predict the cost effectiveness of SFRP wrapped concrete columns is also suggested, from which, a parametric study was conducted. The parametric study investigated the effect of the concrete strength, the number of SFRP layers, and the size and slenderness effects on the cost effectiveness of the concrete columns wrapped with SFRP sheets. The results from the cost and ductility effectiveness study indicated that the SFRP wrapped concrete columns showed enhanced performance over the CFRP wrapped concrete columns. The suggested analytical procedure proved to be a reliable and accurate method to predict the cost effectiveness parameter of SFRP wrapped concrete columns. The parametric study showed the significant impact of the investigated parameters on the cost effectiveness of concrete columns wrapped with SFRP sheets.

  2. Comparison of the release of constituents from granular materials under batch and column testing.

    Science.gov (United States)

    Lopez Meza, Sarynna; Garrabrants, Andrew C; van der Sloot, Hans; Kosson, David S

    2008-01-01

    Column leaching testing can be considered a better basis for assessing field impact data than any other available batch test method and thus provides a fundamental basis from which to estimate constituent release under a variety of field conditions. However, column testing is time-intensive compared to the more simplified batch testing, and may not always be a viable option when making decisions for material reuse. Batch tests are used most frequently as a simple tool for compliance or quality control reasons. Therefore, it is important to compare the release that occurs under batch and column testing, and establish conservative interpretation protocols for extrapolation from batch data when column data are not available. Five different materials (concrete, construction debris, aluminum recycling residue, coal fly ash and bottom ash) were evaluated via batch and column testing, including different column flow regimes (continuously saturated and intermittent unsaturated flow). Constituent release data from batch and column tests were compared. Results showed no significant difference between the column flow regimes when constituent release data from batch and column tests were compared. In most cases batch and column testing agreed when presented in the form of cumulative release. For arsenic in carbonated materials, however, batch testing underestimates the column constituent release for most LS ratios and also on a cumulative basis. For cases when As is a constituent of concern, column testing may be required.

  3. Seismic performance of a grout-repaired construction defect in a column plastic hinge

    International Nuclear Information System (INIS)

    Budek, A.

    2006-01-01

    A column built to test the use of high-strength transverse reinforcement in seismically-loaded shear-critical columns was found to have a construction defect. The column was built to be loaded in double bending and as such was expected to develop two plastic hinges, one at each end of column. In the plastic hinge region at the column top, a void was formed because the concrete could not pass through the load stub's reinforcing steel cage. This void was repaired using nonshrink grout placed in a fluid state. The column was tested after repair and performed satisfactorily. The grouted repair was able to support large plastic rotations and allowed the column to reach a high level of ductility. The only effects of the repair were slightly reduced concrete dilation and stiffness in the repaired hinge. (author)

  4. Estimation of bearing capacity of floating group of stone columns

    OpenAIRE

    Fattah, Mohammed Y.; Al-Neami, Mohammed A.; Shamel Al-Suhaily, Ahmed

    2017-01-01

    Stone column is one of the ground improvement techniques. This technique has a proven performance, short time schedule, durability, constructability and low costs. The stone column technique has been used as a method of reinforcement of soft ground over the past 30 years. The bearing capacity of the stone column still has high level of uncertainties because the existing formulas for the estimation of the bearing capacity are general and do not take into consideration the type of the stone col...

  5. Numerical Simulation of Fluid Dynamics in a Monolithic Column

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2017-01-01

    Full Text Available As for the measurement of polycyclic aromatic hydrocarbons (PAHs, ultra-performance liquid chromatography (UPLC is used for PAH identification and densitometry. However, when a solvent containing a substance to be identified passes through a column of UPLC, a dedicated high-pressure-proof device is required. Recently, a liquid chromatography instrument using a monolithic column technology has been proposed to reduce the pressure of UPLC. The present study tested five types of monolithic columns produced in experiments. To simulate the flow field, the lattice Boltzmann method (LBM was used. The velocity profile was discussed to decrease the pressure drop in the ultra-performance liquid chromatography (UPLC system.

  6. Laser pulse stacking method

    Science.gov (United States)

    Moses, E.I.

    1992-12-01

    A laser pulse stacking method is disclosed. A problem with the prior art has been the generation of a series of laser beam pulses where the outer and inner regions of the beams are generated so as to form radially non-synchronous pulses. Such pulses thus have a non-uniform cross-sectional area with respect to the outer and inner edges of the pulses. The present invention provides a solution by combining the temporally non-uniform pulses in a stacking effect to thus provide a more uniform temporal synchronism over the beam diameter. 2 figs.

  7. Mitigation of Oil in Water Column: Concept Development

    Science.gov (United States)

    2016-06-01

    subsea pipeline leaks , or the leaking of oil from tanks after a damaged vessel has sunk to the bottom. Oil arriving at the surface of the water may...i Classification | CG-926 RDC | author | audience | month year Mitigation of Oil in Water Column: Concept Development Distribution...Center. June 2016 Report No. CG-D-03-16 Mitigation of Oil in Water Column: Concept Development ii UNCLAS//Public | CG-926 RDC

  8. Evaluation of Seismic Behaviors of Partially Deteriorated Reinforced Concrete Circular Columns Retrofitted with CFRP

    Directory of Open Access Journals (Sweden)

    Dongxu Hou

    2014-01-01

    Full Text Available Deficiency of the concrete strength in some regions of reinforced concrete (RC columns in practice may weaken the seismic behaviors of columns. Its effects on RC columns should be well understood. This paper aims to investigate the influences of deteriorated segment on the seismic behaviors of partially deteriorated RC columns and attempts to recover the seismic behaviors of partially deteriorated columns with Carbon Fiber Reinforced Polymer (CFRP composites. A finite element analysis was carried out to simulate the seismic behaviors of CFRP-confined partially deteriorated RC columns. The numerical results were verified by the laboratory tests of six specimens. Based on the finite element results, the failure location of partially deteriorated columns in an earthquake was predicted, and the effectiveness of CFRP retrofitted on partially deteriorated columns was evaluated.

  9. Controllable pulse parameter transcranial magnetic stimulator with enhanced circuit topology and pulse shaping

    Science.gov (United States)

    Peterchev, Angel V.; DʼOstilio, Kevin; Rothwell, John C.; Murphy, David L.

    2014-10-01

    Objective. This work aims at flexible and practical pulse parameter control in transcranial magnetic stimulation (TMS), which is currently very limited in commercial devices. Approach. We present a third generation controllable pulse parameter device (cTMS3) that uses a novel circuit topology with two energy-storage capacitors. It incorporates several implementation and functionality advantages over conventional TMS devices and other devices with advanced pulse shape control. cTMS3 generates lower internal voltage differences and is implemented with transistors with a lower voltage rating than prior cTMS devices. Main results. cTMS3 provides more flexible pulse shaping since the circuit topology allows four coil-voltage levels during a pulse, including approximately zero voltage. The near-zero coil voltage enables snubbing of the ringing at the end of the pulse without the need for a separate active snubber circuit. cTMS3 can generate powerful rapid pulse sequences (\\lt 10 ms inter pulse interval) by increasing the width of each subsequent pulse and utilizing the large capacitor energy storage, allowing the implementation of paradigms such as paired-pulse and quadripulse TMS with a single pulse generation circuit. cTMS3 can also generate theta (50 Hz) burst stimulation with predominantly unidirectional electric field pulses. The cTMS3 device functionality and output strength are illustrated with electrical output measurements as well as a study of the effect of pulse width and polarity on the active motor threshold in ten healthy volunteers. Significance. The cTMS3 features could extend the utility of TMS as a research, diagnostic, and therapeutic tool.

  10. EX0904 Water Column Summary Report and Profile Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A complete set of water column profile data and CTD Summary Report (if generated) generated by the Okeanos Explorer during EX0904: Water Column Exploration Field...

  11. Steel-reinforced concrete-filled steel tubular columns under axial and lateral cyclic loading

    Science.gov (United States)

    Farajpourbonab, Ebrahim; Kute, Sunil Y.; Inamdar, Vilas M.

    2018-03-01

    SRCFT columns are formed by inserting a steel section into a concrete-filled steel tube. These types of columns are named steel-reinforced concrete-filled steel tubular (SRCFT) columns. The current study aims at investigating the various types of reinforcing steel section to improve the strength and hysteresis behavior of SRCFT columns under axial and lateral cyclic loading. To attain this objective, a numerical study has been conducted on a series of composite columns. First, FEM procedure has been verified by the use of available experimental studies. Next, eight composite columns having different types of cross sections were analyzed. For comparison purpose, the base model was a CFT column used as a benchmark specimen. Nevertheless, the other specimens were SRCFT types. The results indicate that reinforcement of a CFT column through this method leads to enhancement in load-carrying capacity, enhancement in lateral drift ratio, ductility, preventing of local buckling in steel shell, and enhancement in energy absorption capacity. Under cyclic displacement history, it was observed that the use of cross-shaped reinforcing steel section causes a higher level of energy dissipation and the moment of inertia of the reinforcing steel sections was found to be the most significant parameter affecting the hysteresis behavior of SRCFT columns.

  12. Correction in the efficiency of uranium purification process by solvent extraction

    International Nuclear Information System (INIS)

    Franca Junior, J.M.

    1981-01-01

    An uranium solvent extraction, of high purification, with full advantage of absorbed uranium in the begining of process, is described. Including a pulsed column, called correction column, the efficiency of whole process is increased, dispensing the recycling of uranium losses from leaching column. With the correction column the uranium losses go in continuity, for reextraction column, increasing the efficiency of process. The purified uranium is removed in the reextraction column in aqueous phase. The correction process can be carried out with full efficiency using pulsed columns or chemical mixer-settlers. (M.C.K.) [pt

  13. Comments on Simplified Calculation Method for Fire Exposed Concrete Columns

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl

    1998-01-01

    The author has developed new simplified calculation methods for fire exposed columns. Methods, which are found In ENV 1992-1-2 chapter 4.3 and in proposal for Danish code of Practise DS411 chapter 9. In the present supporting document the methods are derived and 50 eccentrically loaded fire expos...... columns are calculated and compared to results of full-scale tests. Furthermore 500 columns are calculated in order to present each test result related to a variation of the calculation in time of fire resistance....

  14. Breakthrough properties of chloride ions in columns of lead phosphate hydroxide

    International Nuclear Information System (INIS)

    Akiba, Kenichi; Hashimoto, Hiroyuki; Mimura, Hitoshi; Shindo, Manabu.

    1994-01-01

    Breakthrough properties of chloride ion (Cl - ) have been studied by using columns packed with a granular anion-exchanger of lead phosphate hydroxide (Pb 10 (PO 4 ) 6 (OH) 2 , IXE-1000G). The column utilization of the ratio of breakthrough capacity to total capacity increased with decreasing particle size and increasing temperature. The collection of Cl - from a simulated waste solution was improved by the addition of cation-exchange to IXE-1000G; the adsorption capacity of the column of IXE-1000G/IXE-300G (Sb type cation-exchanger) was over 0.16 mmol Cl - /g, yielding a relatively high column utilization of 75%. (author)

  15. Stage wise modeling of liquid-extraction column (RDC)

    International Nuclear Information System (INIS)

    Bastani, B.

    2004-01-01

    Stage wise forward mixing model considering coalescence and re dispersion of drops was used to predict the performance of Rotating Disk Liquid Extraction Contactors. Experimental data previously obtained in two RDC columns of 7-62 cm diameter, 73.6 cm height and 21.9 cm diameter,150 cm height were used to evaluate the model predications. Drops-side mass transfer coefficients were predicted applying Hand los-baron drop model and onley's model was used to predict velocities. According to the results obtained the followings could be concluded: (1) If the height of coalescence and re dispersion i.e.:h=h p Q p / Q could be estimated, the stage wise forward mixing with coalescence and re dispersion model will predict the column height and efficiency with the acceptable accuracy, (2) The stage wise modeling predictions are highly dependent on the number of stages used when the number of stages is less than 10 and (3) Application of continuous phase mass transfer axial dispersion coefficients (k c and E c ) obtained from the solute concentration profile along the column height will predict the column performance more accurately than the Calder bank and moo-young (for K c ) and Kumar-Heartland (for E c ) correlations

  16. NO2 column changes induced by volcanic eruptions

    Science.gov (United States)

    Johnston, Paul V.; Keys, J. Gordon; Mckenzie, Richard L.

    1994-01-01

    Nitrogen dioxide slant column amounts measured by ground-based remote sensing from Lauder, New Zealand (45 deg S) and Campbell Island (53 deg S) during the second half of 1991 and early 1992 show anomalously low values that are attributed to the effects of volcanic eruptions. It is believed that the eruptions of Mount Pinatubo in the Philippines in June 1991 and possibly Mount Hudson in Chile in August 1991 are responsible for the stratospheric changes, which first became apparent in July 1991. The effects in the spring of 1991 are manifested as a reduction in the retrieved NO2 column amounts from normal levels by 35 to 45 percent, and an accompanying increase in the overnight decay of NO2. The existence of an accurate long-term record of column NO2 from the Lauder site enables us to quantify departures from the normal seasonal behavior with some confidence. Simultaneous retrievals of column ozone agree well with Dobson measurements, confirming that only part of the NO2 changes can be attributed to a modification of the scattering geometry by volcanic aerosols. Other reasons for the observed behavior are explored, including the effects of stratospheric temperature increases resulting from the aerosol loading and the possible involvement of heterogeneous chemical processes.

  17. Use of emulsified vegetable oil to support bioremediation of TCE DNAPL in soil columns.

    Science.gov (United States)

    Harkness, Mark; Fisher, Angela

    2013-08-01

    The interaction between emulsified vegetable oil (EVO) and trichloroethylene (TCE) dense non-aqueous phase liquid (DNAPL) was observed using two soil columns and subsequent reductive dechlorination of TCE was monitored over a three year period. Dyed TCE DNAPL (~75 g) was emplaced in one column (DNAPL column), while the second was DNAPL-free (plume column). EVO was added to both columns and partitioning of the EVO into the TCE DNAPL was measured and quantified. TCE (1.9 mM) was added to the influent of the plume column to simulate conditions down gradient of a DNAPL source area and the columns were operated independently for more than one year, after which they were connected in series. Initially limited dechlorination of TCE to cDCE was observed in the DNAPL column, while the plume column supported complete reductive dechlorination of TCE to ethene. Upon connection and reamendment of the plume column with EVO, near saturation levels of TCE from the effluent of the DNAPL column were rapidly dechlorinated to c-DCE and VC in the plume column; however, this high rate dechlorination produced hydrochloric acid which overwhelmed the buffering capacity of the system and caused the pH to drop below 6.0. Dechlorination efficiency in the columns subsequently deteriorated, as measured by the chloride production and Dehalococcoides counts, but was restored by adding sodium bicarbonate buffer to the influent groundwater. Robust dechlorination was eventually observed in the DNAPL column, such that the TCE DNAPL was largely removed by the end of the study. Partitioning of the EVO into the DNAPL provided significant operational benefits to the remediation system both in terms of electron donor placement and longevity. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Seismic fragility analysis of lap-spliced reinforced concrete columns retrofitted by SMA wire jackets

    International Nuclear Information System (INIS)

    Choi, Eunsoo; Park, Sun-Hee; Chung, Young-Soo; Kim, Hee Sun

    2013-01-01

    The aim of this study is to provide seismic fragility curves of reinforced concrete columns retrofitted by shape memory alloy wire jackets and thus assess the seismic performance of the columns against earthquakes, comparing them with reinforced concrete columns with lap-spliced and continuous reinforcement. For that purpose, this study first developed analytical models of the experimental results of the three types of columns, (1) lap-spliced reinforcement, (2) continuous reinforcement and (3) lap-spliced reinforcement and retrofitted by SMA wire jackets, using the OpenSEES program, which is oriented to nonlinear dynamic analysis. Then, a suite of ten recorded ground motions was used to conduct dynamic analyses of the analytical models with scaling of the peak ground acceleration from 0.1g to 1.0g in steps of 0.1g. From the static experimental tests, the column retrofitted with SMA wire jackets had a larger displacement ductility by a factor of 2.3 times that of the lap-spliced column, which was 6% larger compared with the ductility of the continuous reinforcement column. From the fragility analyses, the SMA wire jacketed column had median values of 0.162g and 0.567g for yield and collapse, respectively. For the yield damage state, the SMA wire jacketed column had a median value similar to the continuous reinforcement column. However, for the complete damage state, the SMA wire jacketed column showed a 1.33 times larger median value than the continuously reinforcement column. (paper)

  19. Compressive Strength Prediction of Square Concrete Columns Retrofitted with External Steel Collars

    Directory of Open Access Journals (Sweden)

    Pudjisuryadi, P.

    2013-01-01

    Full Text Available Transverse confining stress in concrete members, commonly provided by transverse reinforcement, has been recognized to enhance strength and ductility. Nowadays, the confining method has been further developed to external confinement approach. This type of confinement can be used for retrofitting existing concrete columns. Many external confining techniques have been proven to be successful in retrofitting circular columns. However, for square or rectangular columns, providing effective confining stress by external retrofitting method is not a simple task due to high stress concentration at column’s corners. This paper proposes an analytical model to predict the peak strength of square concrete columns confined by external steel collars. Comparison with the experimental results showed that the model can predict the peak strength reasonably well. However, it should be noted that relatively larger amount of steel is needed to achieve comparable column strength enhancement when it is compared with those of conve tional internally-confined columns.

  20. Complementary Set Matrices Satisfying a Column Correlation Constraint

    OpenAIRE

    Wu, Di; Spasojevic, Predrag

    2006-01-01

    Motivated by the problem of reducing the peak to average power ratio (PAPR) of transmitted signals, we consider a design of complementary set matrices whose column sequences satisfy a correlation constraint. The design algorithm recursively builds a collection of $2^{t+1}$ mutually orthogonal (MO) complementary set matrices starting from a companion pair of sequences. We relate correlation properties of column sequences to that of the companion pair and illustrate how to select an appropriate...

  1. RF Pulsed Heating

    Energy Technology Data Exchange (ETDEWEB)

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  2. Hydrodynamic chromatography of polystyrene microparticles in micropillar array columns

    NARCIS (Netherlands)

    Op de Beeck, Jeff; de Malsche, Wim; Vangelooven, Joris; Gardeniers, Johannes G.E.; Desmet, Gert

    2010-01-01

    We report on the possibility to perform HDC in micropillar array columns and the potential advantages of such a system. The HDC performance of a pillar array column with pillar diameter = 5 μm and an interpillar distance of 2.5 μm has been characterized using both a low MW tracer (FITC) and

  3. Simulators of tray distillation columns as tools for interpreting ...

    African Journals Online (AJOL)

    ... at 0.05 m intervals were determined from top to the bottom of simulators of tray distillation columns exposed to 20 mCi of 137 Cs. Signals generated from the simulators were identical with the experimental signals obtained from the Stabilizer Column of the crude oil distillation unit at the Tema Oil Refinery Ghana Limited.

  4. Optimal pulse fishing policy in stage-structured models with birth pulses

    International Nuclear Information System (INIS)

    Gao Shujing; Chen Lansun; Sun Lihua

    2005-01-01

    In this paper, we propose exploited models with stage structure for the dynamics in a fish population for which periodic birth pulse and pulse fishing occur at different fixed time. Using the stroboscopic map, we obtain an exact cycle of system, and obtain the threshold conditions for its stability. Bifurcation diagrams are constructed with the birth rate (or pulse fishing time or harvesting effort) as the bifurcation parameter, and these are observed to display complex dynamic behaviors, including chaotic bands with period windows, period-doubling, multi-period-halving and incomplete period-doubling bifurcation, pitch-fork and tangent bifurcation, non-unique dynamics (meaning that several attractors or attractor and chaos coexist) and attractor crisis. This suggests that birth pulse and pulse fishing provide a natural period or cyclicity that make the dynamical behaviors more complex. Moreover, we show that the pulse fishing has a strong impact on the persistence of the fish population, on the volume of mature fish stock and on the maximum annual-sustainable yield. An interesting result is obtained that, after the birth pulse, the population can sustain much higher harvesting effort if the mature fish is removed as early as possible

  5. Design and Operation of Cryogenic Distillation Research Column for Ultra-Low Background Experiments

    Science.gov (United States)

    Chiller, Christopher; Alanson Chiller, Angela; Jasinski, Benjamin; Snyder, Nathan; Mei, Dongming

    2013-04-01

    Motivated by isotopically enriched germanium (76Ge and 73Ge) for monocrystalline crystal growth for neutrinoless double-beta decay and dark matter experiments, a cryogenic distillation research column was developed. Without market availability of distillation columns in the temperature range of interest with capabilities necessary for our purposes, we designed, fabricated, tested, refined and operated a two-meter research column for purifying and separating gases in the temperature range from 100-200K. Due to interest in defining stratification, purity and throughput optimization, capillary lines were integrated at four equidistant points along the length of the column such that real-time residual gas analysis could guide the investigation. Interior gas column temperatures were monitored and controlled within 0.1oK accuracy at the top and bottom. Pressures were monitored at the top of the column to four significant figures. Subsequent impurities were measured at partial pressures below 2E-8torr. We report the performance of the column in this paper.

  6. Versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy

    International Nuclear Information System (INIS)

    Adduci, D.J.

    1979-05-01

    A description of the sequence of events and the decisions leading to the design of a versatile pulse programmer for pulsed NMR are presented. Background and application information is discussed in order that the reader might better understand the role of the pulse programmer in a NMR spectrometer. Various other design approaches are presented as a basis for comparison. Specifications for this design are proposed, the hardware implementation of the specifications is discussed, and the software operating system is presented

  7. Versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Adduci, D.J.

    1979-05-01

    A description of the sequence of events and the decisions leading to the design of a versatile pulse programmer for pulsed NMR are presented. Background and application information is discussed in order that the reader might better understand the role of the pulse programmer in a NMR spectrometer. Various other design approaches are presented as a basis for comparison. Specifications for this design are proposed, the hardware implementation of the specifications is discussed, and the software operating system is presented.

  8. Nondestructive evaluation of warm mix asphalt through resonant column testing.

    Science.gov (United States)

    2014-02-01

    Non-destructive testing has been used for decades to characterize engineering properties of hot-mix asphalt. Among such tests is the resonant column (RC) test, which is commonly used to characterize soil materials. The resonant column device at Penn ...

  9. Cyclic behavior of non-seismically designed interior reinforced concrete beam-column connections

    Directory of Open Access Journals (Sweden)

    Amorn Pimanmas

    2008-05-01

    Full Text Available This paper presents a test of non-seismically detailed reinforced concrete beam-column connections under reversedcyclic load. The tested specimens represented those of the actual mid-rise reinforced concrete frame buildings, designedaccording to the non-seismic provisions of the ACI building code. The evaluation of 10 existing reinforced concrete frameswas conducted to identify key structural and geometrical indices. It was found that there existed correlation VS structuraland geometrical characteristics and the column tributary area. Hence, the column tributary area was chosen as a parameterfor classifying the specimens. The test results showed that specimens representing small and medium column tributary areafailed by brittle joint shear, while specimen representing large column tributary area failed by ductile flexure, even thoughno ductile seismic details were provided.

  10. A compact bipolar pulse-forming network-Marx generator based on pulse transformers.

    Science.gov (United States)

    Zhang, Huibo; Yang, Jianhua; Lin, Jiajin; Yang, Xiao

    2013-11-01

    A compact bipolar pulse-forming network (PFN)-Marx generator based on pulse transformers is presented in this paper. The high-voltage generator consisted of two sets of pulse transformers, 6 stages of PFNs with ceramic capacitors, a switch unit, and a matched load. The design is characterized by the bipolar pulse charging scheme and the compact structure of the PFN-Marx. The scheme of bipolar charging by pulse transformers increased the withstand voltage of the ceramic capacitors in the PFNs and decreased the number of the gas gap switches. The compact structure of the PFN-Marx was aimed at reducing the parasitic inductance in the generator. When the charging voltage on the PFNs was 35 kV, the matched resistive load of 48 Ω could deliver a high-voltage pulse with an amplitude of 100 kV. The full width at half maximum of the load pulse was 173 ns, and its rise time was less than 15 ns.

  11. Evaluation of chromatographic columns packed with semi- and fully porous particles for benzimidazoles separation.

    Science.gov (United States)

    Gonzalo-Lumbreras, Raquel; Sanz-Landaluze, Jon; Cámara, Carmen

    2015-07-01

    The behavior of 15 benzimidazoles, including their main metabolites, using several C18 columns with standard or narrow-bore diameters and different particle size and type were evaluated. These commercial columns were selected because their differences could affect separation of benzimidazoles, and so they can be used as alternative columns. A simple screening method for the analysis of benzimidazole residues and their main metabolites was developed. First, the separation of benzimidazoles was optimized using a Kinetex C18 column; later, analytical performances of other columns using the above optimized conditions were compared and then individually re-optimized. Critical pairs resolution, analysis run time, column type and characteristics, and selectivity were considered for chromatographic columns comparison. Kinetex XB was selected because it provides the shortest analysis time and the best resolution of critical pairs. Using this column, the separation conditions were re-optimized using a factorial design. Separations obtained with the different columns tested can be applied to the analysis of specific benzimidazoles residues or other applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Development of bipolar pulse accelerator for intense pulsed ion beam acceleration

    International Nuclear Information System (INIS)

    Fujioka, Y.; Mitsui, C.; Kitamura, I.; Takahashi, T.; Masugata, K.; Tanoue, H.; Arai, K.

    2003-01-01

    To improve the purity of an intense pulsed ion beams a new type of pulsed ion beam accelerator named 'bipolar pulse accelerator (BPA)' was proposed. In the accelerator purity of the beam is expected. To confirm the principle of the accelerator experimental system was developed. The system utilizes B y type magnetically insulated acceleration gap and operated with single polar negative pulse. A coaxial gas puff plasma gun placed in the grounded anode was used as an ion source, and source plasma (nitrogen) of current density approx. = 25 A/cm 2 , duration approx. = 1.5 μs was injected into the acceleration gap. The ions are successfully accelerated from the grounded anode to the drift tube by applying negative pulse of voltage 180 kV, duration 60 ns to the drift tube. Pulsed ion beam of current density approx. = 40 A/cm 2 , duration approx. 60 ns was obtained at 42 mm downstream from the anode surface. (author)

  13. Producing High Intense Attosecond Pulse Train by Interaction of Three-Color Pulse and Overdense Plasma

    Science.gov (United States)

    Salehi, M.; Mirzanejad, S.

    2017-05-01

    Amplifying the attosecond pulse by the chirp pulse amplification method is impossible. Furthermore, the intensity of attosecond pulse is low in the interaction of laser pulse and underdense plasma. This motivates us to propose using a multi-color pulse to produce the high intense attosecond pulse. In the present study, the relativistic interaction of a three-color linearly-polarized laser-pulse with highly overdense plasma is studied. We show that the combination of {{ω }}1, {{ω }}2 and {{ω }}3 frequencies decreases the instance full width at half maximum reflected attosecond pulse train from the overdense plasma surface. Moreover, we show that the three-color pulse increases the intensity of generated harmonics, which is explained by the relativistic oscillating mirror model. The obtained results demonstrate that if the three-color laser pulse interacts with overdense plasma, it will enhance two orders of magnitude of intensity of ultra short attosecond pulses in comparison with monochromatic pulse.

  14. Nonlinear scattering from a plasma column. I - Theory. II Special cases

    Science.gov (United States)

    Crawford, F. W.; Harker, K. J.

    1983-01-01

    The scattered signal excited by nonlinear mixing of two plane waves normally incident on an infinitely long column of plasma is investigated. A general solution is obtained for the polarization in which the electric field vectors of the waves are perpendicular to the column axis and the column is assumed to be radically inhomogeneous. This general theory is then applied to the special cases of the inhomogeneous column in the long-wavelength limit, and the homogeneous column both for the general case and in the long-wavelength limit. It is determined that dipole and quadrupole components should predominate in the polar radiation pattern for the long-wavelength case. The special case of second harmonic generation due to a single incident wave is analyzed in detail. Nonlinear scattering coefficients are computed, and the corresponding polar radiation patterns are determined. The findings of this study are employed to evaluate the feasibility of observing nonlinear scattering from meteor trails.

  15. Practical issues relating to soil column chromatography for sorption parameter determination.

    Science.gov (United States)

    Bi, Erping; Schmidt, Torsten C; Haderlein, Stefan B

    2010-08-01

    Determination of sorption distribution coefficients (K(d)) of organic compounds by a dynamic soil column chromatography (SCC) method was developed and validated. Eurosoil 4, quartz, and alumina were chosen as exemplary packing materials. Heterocyclic aromatic compounds were selected in the validation of SCC. The prerequisites of SCC with regard to column dimension, packing procedure, and sample injection volume are discussed. Reproducible soil column packing was achieved by addition of a pre-column and an HPLC pump for subsequent compression of the packed material. Various methods to determine retention times from breakthrough curves are discussed and the use of the half mass method is recommended. To dilute soil with inert material can prevent column-clogging and help to complete experiments in a reasonable period of time. For the chosen probe compounds, quartz rather than alumina proved a suitable dilution material. Non-equilibrium issue can be overcome by conducting the experiments under different flowrates and/or performing numerical simulation. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Assembly procedure for column cutting platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Column Cutting Platform and Elevation Support. The Column Cutting Platform is a component of the 241-SY-101 Equipment Removal System. It is set up on the deck of the Strongback Trailer to provide work access to cut off the upper portion of the Mitigation Pump Assembly (MPA). The Elevation Support provides support for the front of the Storage Container with the Strongback at an inclined position. The upper portion of the MPA must be cut off to install the Containment Caps on the Storage Container. The storage Container must be maintained in an inclined position until the Containment Caps are installed to prevent any residual liquids from migrating forward in the Storage Container

  17. Comparative Analysis of Existing RC Columns Jacketed with CFRP or FRCC

    Directory of Open Access Journals (Sweden)

    Marta Del Zoppo

    2018-03-01

    Full Text Available Reinforced concrete (RC columns typical of existing structures often exhibit premature failures during seismic events (i.e., longitudinal bars buckling and shear interaction mechanisms due to the poor quality concrete and the absence of proper seismic details in the potential plastic hinge region. The Fiber Reinforced Polymers (FRP externally bonded reinforcement is known to be a valid technique to improve the shear capacity or the ductility of existing RC columns. However, few experimental tests have proven its effectiveness in the case of columns affected by shear interaction mechanisms. In this work, the behavior of existing RC columns with border line behavior between flexure and shear have been investigated in the case of poor quality concrete and light FRP strengthening with local jacketing and medium quality concrete and strong FRP strengthening with local jacketing, in order to highlight the effect of concrete strength on the effectiveness of the retrofit intervention. As an alternative to FRP jacketing; the effectiveness of the Fiber Reinforced Cementitious Composite (FRCC jacketing for the seismic strengthening of columns with highly deteriorated concrete cover or columns already damaged by an earthquake is also evaluated. Six full-scale RC columns have been tested under cyclic loading: one was used as a control specimen; four were strengthened in the potential plastic hinge region with carbon FRP (CFRP; and one was fully jacketed with FRCC. The comparison between poor and medium quality concrete columns showed that the CFRP local jacketing is more effective in the case of poor quality concrete. The FRCC jacketing appears to be a sound repair strategy and a suitable alternative to the FRP jacketing in case of poor quality; however, more experimental research is needed for improving this retrofit technique.

  18. Built for speed: strain in the cartilaginous vertebral columns of sharks.

    Science.gov (United States)

    Porter, M E; Diaz, Candido; Sturm, Joshua J; Grotmol, Sindre; Summers, A P; Long, John H

    2014-02-01

    In most bony fishes vertebral column strain during locomotion is almost exclusively in the intervertebral joints, and when these joints move there is the potential to store and release strain energy. Since cartilaginous fishes have poorly mineralized vertebral centra, we tested whether the vertebral bodies undergo substantial strain and thus may be sites of energy storage during locomotion. We measured axial strains of the intervertebral joints and vertebrae in vivo and ex vivo to characterize the dynamic behavior of the vertebral column. We used sonomicrometry to directly measure in vivo and in situ strains of intervertebral joints and vertebrae of Squalus acanthias swimming in a flume. For ex vivo measurements, we used a materials testing system to dynamically bend segments of vertebral column at frequencies ranging from 0.25 to 1.00 Hz and a range of physiologically relevant curvatures, which were determined using a kinematic analysis. The vertebral centra of S. acanthias undergo strain during in vivo volitional movements as well as in situ passive movements. Moreover, when isolated segments of vertebral column were tested during mechanical bending, we measured the same magnitudes of strain. These data support our hypothesis that vertebral column strain in lateral bending is not limited to the intervertebral joints. In histological sections, we found that the vertebral column of S. acanthias has an intracentral canal that is open and covered with a velum layer. An open intracentral canal may indicate that the centra are acting as tunics around some sections of a hydrostat, effectively stiffening the vertebral column. These data suggest that the entire vertebral column of sharks, both joints and centra, is mechanically engaged as a dynamic spring during locomotion. Copyright © 2013 Elsevier GmbH. All rights reserved.

  19. Optimization study of distillation column based on Type I absorption heat pump

    International Nuclear Information System (INIS)

    Li, Yan; Wang, Lu; Zhu, Meng; Wang, Weiqin

    2017-01-01

    Highlights: • Propose a new distillation system based on Type I absorption heat pump. • The optimum condition of the system is obtained. • The energy consumption of the system is reduced by 23.3% significantly. • The benefits of economy and energy-saving for the new distillation system are distinct. - Abstract: Due to the thermodynamic deficiencies in general pressurized distillation process, a new distillation system based on Type I AHP (absorption heat pump) is proposed in this paper. The proposed system uses AHP to recover the waste heat from column condenser and reheat the feed materials of column; meanwhile, the cooling capacity of column condenser can be increased, which leads to the decrease of the pressure in distillation column. With general distillation system of depropanizing column (C-101) as an example, using numerical simulation software Aspen Plus, the effect of inner parameters on the energy consumption has been conducted to approach the general rules of energy saving in distillation. Then the new distillation system is adopted and the optimization of its energy consumption is conducted to determine the optimum operating condition. The numerical simulation results show that the steam consumption can be decreased by 23.3% compared with general C-101 system, reaching the minimum. Moreover, the extra heat output of AHP is treated as the heat source for the reboilers of deethanization column (C-102) and refined propylene column (C-103), which reduces the total steam consumption of three-column processes by 22.1%.

  20. Adsorption and transport of cadmium and rhodamine WT in pumice sand columns

    International Nuclear Information System (INIS)

    Pang, L.; Close, M.; Greenfield, H.; Stanton, G.

    2004-01-01

    The transport and attenuation of cadmium (Cd) and rhodamine WT (RWT) in a pumice sand aquifer media was investigated using column experiments to study a scenario of point-source contamination. A pore-water velocity of 1.7-1.8 m/day, which is a typical field groundwater velocity in a pumice sand aquifer system, was applied to triplicate columns. A pulse of a solution containing Cd and RWT, together with the conservative tracer tritiated water ( 3 H 2 O) at pH = 7, was introduced into the columns. Experimental results showed that concentration breakthrough curves (BTCs) of 3 H 2 O were symmetrical and fitted well into an equilibrium model. In contrast, BTCs of Cd and RWT were asymmetrical with significant tailings and fitted well with a two-site adsorption/desorption model. The symmetric 3 H 2 O BTCs suggest that physical non-equilibrium was absent in the experimental system, therefore the asymmetrical BTCs of Cd and RWT were attributed to chemical non-equilibrium. Modelling results showed that, in comparison with 3 H 2 O, Cd was apparently retarded by 101-108 times in pumice sand aquifer media (apparent adsorption coefficient 7.33-9.24 ml/g) and underwent a mass loss of 20-30% that was probably because of precipitation of CdCO 3 . As CdCO 3 is extremely insoluble, Cd precipitation would be irreversible and therefore it would not contribute to the tailing of the Cd BTCs. The experimental results suggest that the adsorption and desorption of Cd in pumice sand aquifer media in hydrodynamic conditions was a kinetic process. Cd desorption rates were two orders-of-magnitude slower than its adsorption rates. This resulted in a prolonged mean residence time for Cd in pumice sand aquifer media, which was 10-12 days in the 18-cm-long columns under a flow velocity of 1.7-1.8 m/day. Since the mean residence time is only indicative for the arrival of the central of mass in a contaminant BTC, the time required for the total disappearance of Cd will be much longer than the mean

  1. Vertebral column regionalisation in Chinook salmon, Oncorhynchus tshawytscha.

    Science.gov (United States)

    De Clercq, A; Perrott, M R; Davie, P S; Preece, M A; Wybourne, B; Ruff, N; Huysseune, A; Witten, P E

    2017-10-01

    Teleost vertebral centra are often similar in size and shape, but vertebral-associated elements, i.e. neural arches, haemal arches and ribs, show regional differences. Here we examine how the presence, absence and specific anatomical and histological characters of vertebral centra-associated elements can be used to define vertebral column regions in juvenile Chinook salmon (Oncorhynchus tshawytscha). To investigate if the presence of regions within the vertebral column is independent of temperature, animals raised at 8 and 12 °C were studied at 1400 and 1530 degreedays, in the freshwater phase of the life cycle. Anatomy and composition of the skeletal tissues of the vertebral column were analysed using Alizarin red S whole-mount staining and histological sections. Six regions, termed I-VI, are recognised in the vertebral column of specimens of both temperature groups. Postcranial vertebrae (region I) carry neural arches and parapophyses but lack ribs. Abdominal vertebrae (region II) carry neural arches and ribs that articulate with parapophyses. Elastic- and fibrohyaline cartilage and Sharpey's fibres connect the bone of the parapophyses to the bone of the ribs. In the transitional region (III) vertebrae carry neural arches and parapophyses change stepwise into haemal arches. Ribs decrease in size, anterior to posterior. Vestigial ribs remain attached to the haemal arches with Sharpey's fibres. Caudal vertebrae (region IV) carry neural and haemal arches and spines. Basidorsals and basiventrals are small and surrounded by cancellous bone. Preural vertebrae (region V) carry neural and haemal arches with modified neural and haemal spines to support the caudal fin. Ural vertebrae (region VI) carry hypurals and epurals that represent modified haemal and neural arches and spines, respectively. The postcranial and transitional vertebrae and their respective characters are usually recognised, but should be considered as regions within the vertebral column of teleosts

  2. Concave pulse shaping of a circularly polarized laser pulse from non-uniform overdense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Min Sup [School of Natural Science, UNIST, BanYeon-Ri 100, Ulju-gun, Ulsan, 689-798 (Korea, Republic of); Kulagin, Victor V. [Sternberg Astronomical Institute, Moscow State University, Universitetsky prosp. 13, Moscow, 119992 (Russian Federation); Suk, Hyyong, E-mail: hysuk@gist.ac.kr [Department of Physics and Photon Science, GIST, 123 Cheomdan-gwangiro, Buk-gu, Gwangju, 500-712 (Korea, Republic of)

    2015-03-20

    Pulse shaping of circularly polarized laser pulses in nonuniform overdense plasmas are investigated numerically. Specifically we show by two-dimensional particle-in-cell simulations the generation of a concave pulse front of a circularly polarized, a few tens of petawatt laser pulse from a density-tapered, overdense plasma slab. The concept used for the transverse-directional shaping is the differential transmittance depending on the plasma density, and the laser intensity. For suitable selection of the slab parameters for the concave pulse shaping, we studied numerically the pulse transmittance, which can be used for further parameter design of the pulse shaping. The concavely shaped circularly polarized pulse is expected to add more freedom in controlling the ion-beam characteristics in the RPDA regime. - Highlights: • Laser pulse shaping for a concave front by non-uniform overdense plasma was studied. • Particle-in-cell (PIC) simulations were used for the investigation. • A laser pulse can be shaped by a density-tapered overdense plasma. • The concave and sharp pulse front are useful in many laser–plasma applications. • They are important for ion acceleration, especially in the radiation pressure dominant regime.

  3. Long-pulse applications of pulse-forming lines for high-power linac application

    International Nuclear Information System (INIS)

    Hoeberling, R.F.; Tallerico, P.J.

    1981-01-01

    The ever present demands for high efficiency in the RF power stations for particle accelerators have caused increased interest in longer RF pulses (ten's of microseconds) for linacs such as the Pion Generator for Medical Irradiation (PIGMI) and Free Electron Laser (FEL). For either RF power station, a fundamental decision is whether to use a modulating anode/hard-tube driver or pulsed cathode/line-type pulser configuration. The choices in the extremes of low power for very long pulses or for very-high-power, short pulses are, respectively, a modulated anode/hard tube modulator and pulsed cathode/pulse forming line. However, the demarcation between these two extremes is not clearcut. The criteria (cost, flexibility performance, reliability, efficiency) that resulted in the RF station definition of these two specific systems will be described

  4. Migration of 99Tc in a weak loess aquifer. A field column experiment

    International Nuclear Information System (INIS)

    Liu, C.L.; Wang, X.Y.; Wang, H.F.

    2001-01-01

    The migration of 99 Tc in a weak loess aquifer was investigated in-situ with undisturbed aquifer medium columns. The columns were obtained horizontally at a depth of 32∼36 m in an Underground Research Facility (URF). Quartz containing 3 H (HTO) and 99 Tc (in the form of 99 TcO 4 - ) was introduced into one end of the columns and the columns were covered tightly. Aquifer water was introduced into the columns directly from an experimental shaft in the UFR. Effluents from the columns were collected and the activity of 3 H and 99 Tc were determined with a liquid scintillation analyzer. The breakthrough curves of 3 H and 99 Tc indicate that 99 Tc migrates a little faster than that 3 H does in the aquifer. (author)

  5. MINIMUM BRACING STIFFNESS FOR MULTI-COLUMN SYSTEMS: THEORY

    OpenAIRE

    ARISTIZÁBAL-OCHOA, J. DARÍO

    2011-01-01

    A method that determines the minimum bracing stiffness required by a multi-column elastic system to achieve non-sway buckling conditions is proposed. Equations that evaluate the required minimum stiffness of the lateral and torsional bracings and the corresponding “braced" critical buckling load for each column of the story level are derived using the modified stability functions. The following effects are included: 1) the types of end connections (rigid, semirigid, and simple); 2) the bluepr...

  6. Miniaturized protein separation using a liquid chromatography column on a flexible substrate

    International Nuclear Information System (INIS)

    Yang Yongmo; Chae, Junseok

    2008-01-01

    We report a prototype protein separator that successfully miniaturizes existing technology for potential use in biocompatible health monitoring implants. The prototype is a liquid chromatography (LC) column (LC mini-column) fabricated on an inexpensive, flexible, biocompatible polydimethylsiloxane (PDMS) enclosure. The LC mini-column separates a mixture of proteins using size exclusion chromatography (SEC) with polydivinylbenzene beads (5–20 µm in diameter with 10 nm pore size). The LC mini-column is smaller than any commercially available LC column by a factor of ∼11 000 and successfully separates denatured and native protein mixtures at ∼71 psi of the applied fluidic pressure. Separated proteins are analyzed using NuPAGE-gel electrophoresis, high-performance liquid chromatography (HPLC) and an automated electrophoresis system. Quantitative HPLC results demonstrate successful separation based on intensity change: within 12 min, the intensity between large and small protein peaks changed by a factor of ∼20. In further evaluation using the automated electrophoresis system, the plate height of the LC mini-column is between 36 µm and 100 µm. The prototype LC mini-column shows the potential for real-time health monitoring in applications that require inexpensive, flexible implant technology that can function effectively under non-laboratory conditions

  7. Comparison of monolithic silica and polymethacrylate capillary columns for LC

    Czech Academy of Sciences Publication Activity Database

    Moravcová, D.; Jandera, P.; Urban, J.; Planeta, Josef

    2004-01-01

    Roč. 27, 10-11 (2004), s. 789-800 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA203/02/0023 Keywords : monolithic column s * capillary HPLC * column testing Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.927, year: 2004

  8. 1979-1999 satellite total ozone column measurements over West Africa

    Directory of Open Access Journals (Sweden)

    P. Di Carlo

    2000-06-01

    Full Text Available Total Ozone Mapping Spectrometer (TOMS instruments have been flown on NASA/GSFC satellites for over 20 years. They provide near real-time ozone data for Atmospheric Science Research. As part of preliminary efforts aimed to develop a Lidar station in Nigeria for monitoring the atmospheric ozone and aerosol levels, the monthly mean TOMS total column ozone measurements between 1979 to 1999 have been analysed. The trends of the total column ozone showed a spatial and temporal variation with signs of the Quasi Biennial Oscillation (QBO during the 20-year study period. The values of the TOMS total ozone column, over Nigeria (4-14°N is within the range of 230-280 Dobson Units, this is consistent with total ozone column data, measured since April 1993 with a Dobson Spectrophotometer at Lagos (3°21¢E, 6°33¢N, Nigeria.

  9. Denitrification in the water column of the central Baltic Sea

    DEFF Research Database (Denmark)

    Dalsgaard, Tage; De Brabandere, Loreto; Hall, Per O. J.

    2013-01-01

    Removal of fixed nitrogen in the water column of the eastern Gotland Basin, central Baltic Sea, was studied during two cruises in September 2008 and August 2010. The water column was stratified with anoxic sulfidic bottom water meeting oxic nitrate containing water at the oxic–anoxic interface......3 or sulfide concentrations were converted to in situ rates using the measured water column concentrations of NO3 and sulfide and the actual measured relations between NO3 and sulfide concentrations and enitrification rates. In situ denitrification ranged from 0.24 to 15.9 nM N2 h1. Assuming...... area. Even with an active denitrification layer of 3–6 m thickness the pelagic denitrification per unit area clearly exceeded sediment denitrification rates elsewhere in the Baltic Sea. When extrapolated to the entire Baltic Proper (BP) denitrification in the water column was in the range of 132...

  10. Varied overstrain injuries of the vertebral column conditioned by evolution

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbach, W

    1983-08-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components.

  11. Varied overstrain injuries of the vertebral column conditioned by evolution

    International Nuclear Information System (INIS)

    Kohlbach, W.

    1983-01-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components. (orig.) [de

  12. Earthquake Resilient Bridge Columns Utilizing Damage Resistant Hybrid Fiber Reinforced Concrete

    OpenAIRE

    Trono, William Dean

    2014-01-01

    Modern reinforced concrete bridges are designed to avoid collapse and to prevent loss of life during earthquakes. To meet these objectives, bridge columns are typically detailed to form ductile plastic hinges when large displacements occur. California seismic design criteria acknowledges that damage such as concrete cover spalling and reinforcing bar yielding may occur in columns during a design-level earthquake. The seismic resilience of bridge columns can be improved through the use of a da...

  13. Development of bipolar-pulse accelerator for intense pulsed ion beam acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Masugata, Katsumi [Department of Electrical and Electronic System Engineering, Toyama University, 3190 Gofuku, Toyama 930-8555 (Japan)]. E-mail: masugata@eng.toyama-u.ac.jp; Shimizu, Yuichro [Department of Electrical and Electronic System Engineering, Toyama University, 3190 Gofuku, Toyama 930-8555 (Japan); Fujioka, Yuhki [Department of Electrical and Electronic System Engineering, Toyama University, 3190 Gofuku, Toyama 930-8555 (Japan); Kitamura, Iwao [Department of Electrical and Electronic System Engineering, Toyama University, 3190 Gofuku, Toyama 930-8555 (Japan); Tanoue, Hisao [National Institute of Advanced Industry Science and Technology, 1-1-1, Umezono, Tsukuba-shi, Ibaraki 305-8568 (Japan); Arai, Kazuo [National Institute of Advanced Industry Science and Technology, 1-1-1, Umezono, Tsukuba-shi, Ibaraki 305-8568 (Japan)

    2004-12-21

    To improve the purity of intense pulsed ion beams, a new type of pulsed ion beam accelerator named 'bipolar pulse accelerator' was proposed. To confirm the principle of the accelerator a prototype of the experimental system was developed. The system utilizes By type magnetically insulated acceleration gap and operated with single polar negative pulse. A coaxial gas puff plasma gun was used as an ion source, which was placed inside the grounded anode. Source plasma (nitrogen) of current density {approx}25A/cm2, duration {approx}1.5{mu}s was injected into the acceleration gap by the plasma gun. The ions were successfully accelerated from the grounded anode to the drift tube by applying negative pulse of voltage 240kV, duration 100ns to the drift tube. Pulsed ion beam of current density {approx}40A/cm2, duration {approx}50ns was obtained at 41mm downstream from the anode surface. To evaluate the irradiation effect of the ion beam to solid material, an amorphous silicon thin film of thickness {approx}500nm was used as the target, which was deposited on the glass substrate. The film was found to be poly-crystallized after 4-shots of the pulsed nitrogen ion beam irradiation.

  14. Conceptual analysis of single-feed heterogeneous distillation columns

    Directory of Open Access Journals (Sweden)

    Carlos Arturo Martinez Riascos

    2015-05-01

    Full Text Available Separation in heterogeneous distillation columns is attained by interaction of two liquid and one vapor phases, interaction of three phases involves complexities due to the determination of vapor-liquid-liquid equilibrium and hence, in the design of separation units. Nevertheless, the liquid-liquid equilibrium allows developing separations that may be unfeasible by vapor-liquid equilibrium. In this way, heterogeneous azeotropic distillation is a useful operation for the separation of azeotropic and close-boiling mixtures. In this work, a new methodology for evaluating the feasibility of this process is developed. This methodology is an extension of that proposed by Castillo et al. (1998 for homogeneous systems. Operation leaves for heterogeneous systems are calculated using the concept of pinch point curves in order to establish the process feasibility. Heterogeneous columns with external decanter are considered as the only heterogeneous stage (OHED: only heterogeneous external decanter. The initialization process for the column calculation requires the selection of the distillate composition using thermodynamic criteria in order to guarantee homogeneous phases within the column. A system with industrial and academic relevance was considered as case study: water-acetic acid-amyl acetate. Results show that the developed shortcut method allows evaluating process feasibility and estimating design parameters, without the use of trial and error procedures implemented, with the aid of simulation tools.

  15. Bubble Size Distribution in a Vibrating Bubble Column

    Science.gov (United States)

    Mohagheghian, Shahrouz; Wilson, Trevor; Valenzuela, Bret; Hinds, Tyler; Moseni, Kevin; Elbing, Brian

    2016-11-01

    While vibrating bubble columns have increased the mass transfer between phases, a universal scaling law remains elusive. Attempts to predict mass transfer rates in large industrial scale applications by extrapolating laboratory scale models have failed. In a stationary bubble column, mass transfer is a function of phase interfacial area (PIA), while PIA is determined based on the bubble size distribution (BSD). On the other hand, BSD is influenced by the injection characteristics and liquid phase dynamics and properties. Vibration modifies the BSD by impacting the gas and gas-liquid dynamics. This work uses a vibrating cylindrical bubble column to investigate the effect of gas injection and vibration characteristics on the BSD. The bubble column has a 10 cm diameter and was filled with water to a depth of 90 cm above the tip of the orifice tube injector. BSD was measured using high-speed imaging to determine the projected area of individual bubbles, which the nominal bubble diameter was then calculated assuming spherical bubbles. The BSD dependence on the distance from the injector, injector design (1.6 and 0.8 mm ID), air flow rates (0.5 to 5 lit/min), and vibration conditions (stationary and vibration conditions varying amplitude and frequency) will be presented. In addition to mean data, higher order statistics will also be provided.

  16. Measurement of capacity coefficient of inclined liquid phase catalytic exchange column for tritiated water processing

    International Nuclear Information System (INIS)

    Yamai, Hideki; Konishi, Satoshi; Yamanishi, Toshihiko; Okuno, Kenji

    1994-01-01

    Liquid phase catalytic exchange (LPCE) is effective method for enrichment and removal of tritium from tritiated water. Capacity coefficients of operating LPCE column that are essential to evaluate column performance were measured. Experiments were performed with short catalyst packed columns and effect of inclination was studied. Method for evaluation of capacity coefficients was established from measurement of isotope concentration of liquid, vapor, gas phases at the two ends of the column. The capacity coefficients were measured under various superficial gas velocities. Feasibility study of helical columns with roughened inner surface was performed with short inclined columns. The column performance was not strongly affected by the inclination. The result indicates technological feasibility of helical LPCE column, that is expected to have operation stability and reduced height

  17. Automation of column-based radiochemical separations. A comparison of fluidic, robotic, and hybrid architectures

    Energy Technology Data Exchange (ETDEWEB)

    Grate, J.W.; O' Hara, M.J.; Farawila, A.F.; Ozanich, R.M.; Owsley, S.L. [Pacific Northwest National Laboratory, Richland, WA (United States)

    2011-07-01

    Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on using disposable components so that no sample contacts any surface that any other sample has contacted, and setting up samples and columns in parallel for subsequent automated processing. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions one of four rows of six vials below the columns. The samples are delivered to each column via a manual 3-port disposable valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is a simpler more efficient approach for performing anion exchange procedures for the recovery and purification of plutonium from samples. The automation architectures described can also be adapted to column-based extraction chromatography separations. (orig.)

  18. Anomalous electrical signals associated with microbial activity: Results from Iron and Nitrate-Reducing Columns

    Science.gov (United States)

    Aaron, R. B.; Zheng, Q.; Flynn, P.; Singha, K.; Brantley, S.

    2008-12-01

    Three flow-through columns outfitted with Ag/AgCl electrodes were constructed to test the effects of different microbial processes on the geophysical measurements of self potential (SP), bulk electrical conductivity (σ b), and induced polarization (IP). The columns were filled with sieved, Fe-bearing subsurface sediment from the Delmarva Peninsula near Oyster, VA, inoculated (9:1 ratio) with a freshly-collected, shallow subsurface sediment from a wetland floodplain (Dorn Creek) near Madison, WI. Each of the columns was fed anoxic and sterile PIPES buffered artificial groundwater (PBAGW) containing different concentrations of acetate and nitrate. The medium fed to Column 1 (nitrate-reducing) was amended with 100 μM acetate and 2 mM nitrate. Column 2 (iron-reducing) was run with PBAGW containing 1.0 mM acetate and 0 mM nitrate. Column 3 (alternating redox state) was operated under conditions designed to alternately stimulate nitrate-reducing and iron-reducing populations to provide conditions, i.e., the presence of both nitrate and microbially-produced Fe(II), that would allow growth of nitrate-dependent Fe(II)-oxidizing populations. We operated Column 3 with a cycling strategy of 14-18 days of high C medium (1 mM acetate and 100 μ M nitrate) followed by 14-18 days of low C medium (100 μ M acetate and 2 mM nitrate). Effluent chemistry (NO3-, NO2-, NH4+, acetate, and Fe2+) was sampled daily for four months so as to be concurrent with the electrical measurements. We observed chemical evidence of iron reduction (dissolved [Fe(II)] = 0.2mM) in the effluent from the iron reduction and alternating redox columns. Chemical depletion of NO3- ([NO3-] ranged from 1 to 0.02mM), the production of NO2-, and possible production of NH4+ (0.2 mM) was observed in the nitrate reducing column as well as the alternating redox column. All three columns displayed loss of acetate as microbial activity progressed. σ b remained constant in the alternating redox column (~0.15 S

  19. Flow rate dependent extra-column variance from injection in capillary liquid chromatography.

    Science.gov (United States)

    Aggarwal, Pankaj; Liu, Kun; Sharma, Sonika; Lawson, John S; Dennis Tolley, H; Lee, Milton L

    2015-02-06

    Efficiency and resolution in capillary liquid chromatography (LC) can be significantly affected by extra-column band broadening, especially for isocratic separations. This is particularly a concern in evaluating column bed structure using non-retained test compounds. The band broadening due to an injector supplied with a commercially available capillary LC system was characterized from experimental measurements. The extra-column variance from the injection valve was found to have an extra-column contribution independent of the injection volume, showing an exponential dependence on flow rate. The overall extra-column variance from the injection valve was found to vary from 34 to 23 nL. A new mathematical model was derived that explains this exponential contribution of extra-column variance on chromatographic performance. The chromatographic efficiency was compromised by ∼130% for a non-retained analyte because of injection valve dead volume. The measured chromatographic efficiency was greatly improved when a new nano-flow pumping system with integrated injection valve was used. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. A novel ionic liquid monolithic column and its separation properties in capillary electrochromatography

    International Nuclear Information System (INIS)

    Wang Yu; Deng Qiliang; Fang Guozhen; Pan Mingfei; Yu Yang; Wang Shuo

    2012-01-01

    Highlights: ► ILs as functional monomer for capillary monolithic column. ► Separation of alkylbenzenes, thiourea analogues, and amino acids. ► The column generate a stable reversed EOF from pH 2.0 to 12.0. ► The column efficiency of 147,000 plates m −1 was obtained for thiourea. - Abstract: A novel ionic liquid (IL) monolithic capillary column was successfully prepared by thermal free radical copolymerization of IL (1-vinyl-3-octylimidazolium chloride, ViOcIm + Cl − ) together with lauryl methacrylate (LMA) as the binary functional monomers and ethylene dimethacrylate (EDMA) as the cross-linker in binary porogen. The proportion of monomers, porogens and cross-linker in the polymerization mixture was optimized in detail. The resulting IL-monolithic column could not only generate a stable reversed electroosmotic flow (EOF) in a wide pH range (2.0–12.0), but also effectively eliminate the wall adsorption of the basic analytes. The obtained IL-monolithic columns were examined by scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR). These results indicated that the IL-monolithic capillary column possessed good pore properties, mechanical stability and permeability. The column performance was also evaluated by separating different kinds of compounds, such as alkylbenzenes, thiourea and its analogues, and amino acids. The lowest plate height of ∼6.8 μm was obtained, which corresponded to column efficiency (theoretical plates, N) of ∼147,000 plates m −1 for thiourea. ILs, as a new type of functional monomer, present a promising option in the fabrication of the organic polymer-based monolithic columns in CEC.

  1. Localized giant cell tumors in the spinal column radiologic presentation

    International Nuclear Information System (INIS)

    Fernandez Echeverria, M.A.; Parra Blanco, J.A.; Pagola Serrano, M.A.; Mellado Santos, J.M.; Bueno Lopez, J.; Gonzalez Tutor, A.

    1994-01-01

    Given the uncommonness of the location of giant cell tumors (GCT) in the spinal column and the limited number of studies published, we present a case of GCT located in the spinal column, which involved both vertebral bodies and partially destroyed the adjacent rib. (Author)

  2. A Modeling Framework for Conventional and Heat Integrated Distillation Columns

    DEFF Research Database (Denmark)

    Bisgaard, Thomas; Huusom, Jakob Kjøbsted; Abildskov, Jens

    2013-01-01

    In this paper, a generic, modular model framework for describing fluid separation by distillation is presented. At present, the framework is able to describe a conventional distillation column and a heat-integrated distillation column, but due to a modular structure the database can be further...

  3. Erbium:ytterbium fiber-laser system delivering watt-level femtosecond pulses using divided pulse amplification

    Science.gov (United States)

    Herda, Robert; Zach, Armin

    2015-03-01

    We present an Erbium:Ytterbium codoped fiber-amplifer system based on Divided-Pulses-Amplification (DPA) for ultrashort pulses. The output from a saturable-absorber mode-locked polarization-maintaining (PM) fiber oscillator is amplified in a PM normal-dispersion Erbium-doped fiber. After this stage the pulses are positively chirped and have a duration of 2.0 ps at an average power of 93 mW. A stack of 5 birefringent Yttrium-Vanadate crystals divides these pulses 32 times. We amplify these pulses using a double-clad Erbium:Ytterbium codoped fiber pumped through a multimode fiber combiner. The pulses double pass the amplifier and recombine in the crystals using non-reciprocal polarization 90° rotation by a Faraday rotating mirror. Pulses with a duration of 144 fs are obtained after separation from the input beam using a polarizing beam splitter cube. These pulses have an average power of 1.85 W at a repetition rate of 80 MHz. The generation of femtosecond pulses directly from the amplifier was enabled by a positively chirped seed pulse, normally dispersive Yttrium-Vanadate crystals, and anomalously dispersive amplifier fibers. Efficient frequency doubling to 780 nm with an average power of 725 mW and a pulse duration of 156 fs is demonstrated. In summary we show a DPA setup that enables the generation of femtosecond pulses at watt-level at 1560 nm without the need for further external dechirping and demonstrate a good pulse quality by efficient frequency doubling. Due to the use of PM fiber components and a Faraday rotator the setup is environmentally stable.

  4. The art and science of forming packed analytical high-performance liquid chromatography columns.

    Science.gov (United States)

    Kirkland, J J; Destefano, J J

    2006-09-08

    Columns of packed particles still are the most popular devices for high-performance liquid chromatography (HPLC) separations because of their great utility, excellent performance and wide variety. However, the forming of packed beds for efficient, stable columns traditionally has been an art where the basics of how to form optimum beds generally was not well understood. The recent development of monolith rods was introduced in part to overcome the difficulty of producing stable beds of packing particles. However, these materials are less versatile than packed particle columns. Technology developments in recent years have produced a better understanding among those skilled in the practice of how to form optimized packed beds, and this has led to widely available, high-quality commercial columns. This presentation discusses the developments that led to the present state of column packing technology. Important steps in the packing of efficient, stable beds are described. The key step of selecting the best solvent for the slurry packing method is emphasized. Factors affecting the mechanical stability of packed columns also are discussed. The early art of packing columns now has evolved into a more scientific approach that allows the packing of good columns with a minimum of effort and time.

  5. Investigation of Limit States Specified for Reinforced Concrete Column Members in TEC–2007

    Directory of Open Access Journals (Sweden)

    Umut HASGÜL

    2016-01-01

    Full Text Available In this study, the deformation based limit states stipulated for reinforced concrete members in the Turkish Earthquake Code (TEC were experimentally investigated. Thus four RC cantilever columns which have low concrete compressive strengths and have not adequate confinement, were subjected to constant axial load and cyclic lateral load history. In the study, firstly, the strain values representing the damage limits were converted to top of the column lateral displacements by using fundamentals of structural mechanics. Subsequently the column damages corresponding to the displacement demands were observed, hence limit states were evaluated. After conducting all column tests, it was noted that no column damage was observed for the immediate occupancy (IO performance level defined in the code. For the life safety (LS and collapse prevention (CP performance levels, though somewhat residual deformations occurred on the critical regions, the column members can pretty much sustain their lateral load capacities. It was also observed for all columns that significant damages and strength losses occurred beyond the collapse prevention level. The results of experimental study indicate that the evaluation procedure in the TEC is still in good relationship with the limit states even if the columns have not adequate compressive strength and confinement.

  6. Control characteristics of cryogenic distillation column with a feedback stream for fusion reactor

    International Nuclear Information System (INIS)

    Yamanishi, Toshihiko; Okuno, Kenji

    1997-01-01

    The control characteristics of the cryogenic distillation column with a feedback stream have been discussed based on computer simulation results. This column plays an important role in fusion reactor. A new control system was proposed from the simulation results. The flow rate of top product is determined from the composition and flow rate of a main feed stream by a feedforward control loop. The flow rates of the feedback stream and vapor stream within the column are proportionally changed with a corresponding change of feed flow rate. The flow rate of vapor stream within the column is further adjusted to maintain product purity by a feedback control loop. The proposed system can control the product purity for a large fluctuation of feed composition, a change of feed flow rate, and an increase or decrease of the number of total theoretical stages of the column. The control system should be designed for each column by considering its operating conditions and function. The present study gives us a basic procedure for the design method of the control system of the cryogenic distillation column. (author)

  7. Photoluminescence emission at room temperature in zinc oxide nano-columns

    International Nuclear Information System (INIS)

    Rocha, L.S.R.; Deus, R.C.; Foschini, C.R.; Moura, F.; Garcia, F. Gonzalez; Simões, A.Z.

    2014-01-01

    Highlights: • ZnO nanoparticles were obtained by microwave-hydrothermal method. • X-ray diffraction reveals a hexagonal structure. • Photoluminescence emission evidenced two absorption peaks, at around 480 nm and 590 nm wavelengths. - Abstract: Hydrothermal microwave method (HTMW) was used to synthesize crystalline zinc oxide (ZnO) nano-columns at the temperature of 120 °C with a soaking time of 8 min. ZnO nano-columns were characterized by using X-ray analyses (XRD), infrared spectroscopy (FT-IR), thermogravimetric analyses (TG-DTA), field emission gun and transmission electron microscopy (FEG-SEM and TEM) and photoluminescence properties (PL). XRD results indicated that the ZnO nano-columns are free of any impurity phase and crystallize in the hexagonal structure. Typical FT-IR spectra for ZnO nano-columns presented well defined bands, indicating a substantial short-range order in the system. PL spectra consist of a broad band at 590 nm and narrow band at 480 nm corresponding to a near-band edge emission related to the recombination of excitons and level emission related to structural defects. These results show that the HTMW synthesis route is rapid, cost effective, and could be used as an alternative to obtain ZnO nano-columns in the temperature of 120 °C for 8 min

  8. Photoluminescence emission at room temperature in zinc oxide nano-columns

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, L.S.R.; Deus, R.C. [Universidade Estadual Paulista – Unesp, Faculdade de Engenharia de Guaratinguetá, Av. Dr. Ariberto Pereira da Cunha, 333, Bairro Portal das Colinas, CEP 12516-410 Guaratinguetá, SP (Brazil); Foschini, C.R. [Universidade Estadual Paulista – Unesp, Instituto de Química, Laboratório Interdisciplinar em Cerâmica (LIEC), Rua Professor Francisco Degni s/n, CEP 14800-90 Araraquara, SP (Brazil); Moura, F.; Garcia, F. Gonzalez [Universidade Federal de Itajubá – Unifei, Campus Itabira, Rua São Paulo, 377, Bairro Amazonas, CEP 35900-37 Itabira, MG (Brazil); Simões, A.Z., E-mail: alezipo@yahoo.com [Universidade Estadual Paulista – Unesp, Faculdade de Engenharia de Guaratinguetá, Av. Dr. Ariberto Pereira da Cunha, 333, Bairro Portal das Colinas, CEP 12516-410 Guaratinguetá, SP (Brazil)

    2014-02-01

    Highlights: • ZnO nanoparticles were obtained by microwave-hydrothermal method. • X-ray diffraction reveals a hexagonal structure. • Photoluminescence emission evidenced two absorption peaks, at around 480 nm and 590 nm wavelengths. - Abstract: Hydrothermal microwave method (HTMW) was used to synthesize crystalline zinc oxide (ZnO) nano-columns at the temperature of 120 °C with a soaking time of 8 min. ZnO nano-columns were characterized by using X-ray analyses (XRD), infrared spectroscopy (FT-IR), thermogravimetric analyses (TG-DTA), field emission gun and transmission electron microscopy (FEG-SEM and TEM) and photoluminescence properties (PL). XRD results indicated that the ZnO nano-columns are free of any impurity phase and crystallize in the hexagonal structure. Typical FT-IR spectra for ZnO nano-columns presented well defined bands, indicating a substantial short-range order in the system. PL spectra consist of a broad band at 590 nm and narrow band at 480 nm corresponding to a near-band edge emission related to the recombination of excitons and level emission related to structural defects. These results show that the HTMW synthesis route is rapid, cost effective, and could be used as an alternative to obtain ZnO nano-columns in the temperature of 120 °C for 8 min.

  9. Development of sausage-type instability in a Z-pinch plasma column

    International Nuclear Information System (INIS)

    Vikhrev, V.V.; Ivanov, V.V.; Rozanova, G.A.

    1993-01-01

    The development of sausage-type instabilities in an initially homogeneous Z-pinch plasma column has been investigated by means of numerical modelling. It is shown that in the presence of short-wave perturbations of a Z-pinch boundary and a rarefied plasma surrounding the pinch, cavities filled with a rarefied plasma and with a magnetic field are formed in the plasma column. As a result of this cavity growth, small columns of dense plasma form on the axis in the Z-pinch which have a temperature substantially higher than the average plasma temperature in the plasma column. When deuterium is present in the pinch, these dense high temperature bunches can become a source of intensive neutron radiation. (author). 24 refs, 7 figs

  10. Comprehensive two-dimensional HPLC to study the interaction of multiple components in Rheum palmatum L. with HSA by coupling a silica-bonded HSA column to a silica monolithic ODS column.

    Science.gov (United States)

    Hu, Lianghai; Li, Xin; Feng, Shun; Kong, Liang; Su, Xingye; Chen, Xueguo; Qin, Feng; Ye, Mingliang; Zou, Hanfa

    2006-04-01

    A mode of comprehensive 2-D LC was developed by coupling a silica-bonded HSA column to a silica monolithic ODS column. This system combined the affinity property of the HSA column and the high-speed separation ability of the monolithic ODS column. The affinity chromatography with HSA-immobilized stationary phase was applied to study the interaction of multiple components in traditional Chinese medicines (TCMs) with HSA according to their affinity to protein in the first dimension. Then the unresolved components retained on the HSA column were further separated on the silica monolithic ODS column in the second dimension. By hyphenating the 2-D separation system to diode array detector and MS detectors, the UV and molecular weight information of the separated compounds can also be obtained. The developed separation system was applied to analysis of the extract of Rheum palmatum L., a number of low-abundant components can be separated on a single peak from the HSA column after normalization of peak heights. Six compounds were preliminarily identified according to their UV and MS spectra. It showed that this system was very useful for biological fingerprinting analysis of the components in TCMs and natural products.

  11. Lateral force resisting mechanisms in slab-column connections: An analytical approach

    OpenAIRE

    Drakatos, Iaonnis; Beyer, Katrin; Muttoni, Aurelio

    2014-01-01

    In many countries reinforced concrete (RC) flat slabs supported on columns is one of the most commonly used structural systems for office and industrial buildings. To increase the lateral stiffness and strength of the structure, RC walls are typically added and carry the largest portion of the horizontal loads generated during earthquakes. While the slab-column system is typically not relevant with regard to the lateral stiffness and strength of the structure, each slab-column connection has ...

  12. Flow dynamics in distillation columns packed with Dixon rings as used in isotope separation

    International Nuclear Information System (INIS)

    Gilath, C.; Cohen, H.; Wolf, D.

    1977-01-01

    Packed distillation columns are common in isotope separation. The pressure drop serves as an indication for the hydrodynamic state of the column. Models were formulated for flow and pressure drop dynamics in packed distillation columns. These models were confirmed on columns packed with Dixon rings and operated with water for separation of oxygen isotopes. Liquid holdup displacement is very important in isotope separation practice. Experiments proved that distillation columns packed with Dixon rings exhibit a behaviour close to plug flow. (author)

  13. Experimental Evaluation of Beam to Diamond Box Column Connection with Through Plate in Moment Frames

    International Nuclear Information System (INIS)

    Keshavarzi, Farhad; Torabian, Shahabeddin; Imanpour, Ali; Mirghaderi, Rasoul

    2008-01-01

    Moment resisting frames with built up section have very enhanced features due to high bending stiffness and strength characteristics in two principal axes and access to column faces for beam to column easy connections. But due to proper transfer of beam stresses to column faces there were always some specific controvertibly issues that how to make the load transfer through and in plane manner in order to mobilize the forces in column faces. Using diamond column instead of box column provide possibility to mobilize the load transfer mechanism in column faces. This section as a column has considerable benefit such as high plastic to elastic section modulus ratio which is an effective factor for force controlled components. Typical connection has no chance to be applied with diamond column.This paper elucidates the seismic behavior of through-plates moment connections to diamond box columns for use in steel moment resisting frames. This connection has a lot of economical benefits such as no need to horizontal continuity plates and satisfying the weak beam--strong column criteria in the connection region. They might serve as panel zone plates as well. According to high shear demand in panel zone of beam to column joint one should use the doublers plates in order to decrease the shear strength demand in this sensitive part of structure but these plates have no possibility to mobilize the load transfer mechanism in column web and transfer them to column flanges. In this type of connection, column faces have effective role in order to decrease the demands on through plate and they are impressive factors for improving the performance of the connection.Experimental analysis was conducted to elucidate the seismic behavior of this connection. The results of Experimental analysis established the effectiveness of the through plate in mitigating local stress concentrations and forming the plastic hinge zone in the beam away from the beam to column interface. The moment

  14. DogPulse

    DEFF Research Database (Denmark)

    Skovgaard, Christoffer; Thomsen, Josephine Raun; Verdezoto, Nervo

    2015-01-01

    This paper presents DogPulse, an ambient awareness system to support the coordination of dog walking among family members at home. DogPulse augments a dog collar and leash set to activate an ambient shape-changing lamp and visualize the last time the dog was taken for a walk. The lamp gradually...... changes its form and pulsates its lights in order to keep the family members aware of the dog walking activity. We report the iterative prototyping of DogPulse, its implementation and its preliminary evaluation. Based on our initial findings, we present the limitations and lessons learned as well...

  15. Atomic column resolved electron energy-loss spectroscopy

    International Nuclear Information System (INIS)

    Duscher, G.; Pennycook, S.J.; Browning, N.D.

    1998-01-01

    Spatially resolved electron energy-loss spectroscopy (EELS) is rapidly developing into a unique and powerful tool to characterize internal interfaces. Because atomic column resolved Z-contrast imaging can be performed simultaneously with EELS in the scanning transmission electron microscope, this combination allows the atomic structure to be correlated with the electronic structure, and thus the local properties of interfaces or defects can be determined directly. However, the ability to characterize interfaces and defects at that level requires not only high spatial resolution but also the exact knowledge of the beam location, from where the spectrum is obtained. Here we discuss several examples progressing from cases where the limitation in spatial resolution is given by the microscopes or the nature of the sample, to one example of impurity atoms at a grain boundary, which show intensity and fine structure changes from atomic column to atomic column. Such data can be interpreted as changes in valence of the impurity, depending on its exact site in the boundary plane. Analysis ofthis nature is a valuable first step in understanding the microscopic structural, optical and electronic properties of materials. (orig.)

  16. Optimization of the isotope separation in columns

    International Nuclear Information System (INIS)

    Kaminskij, V.A.; Vetsko, V.M.; Tevzadze, G.A.; Devdariani, O.A.; Sulaberidze, G.A.

    1982-01-01

    The general method for the multi-parameter optimization of cascade plants of packed columns is proposed. As an optimization effectiveness function a netcost of the isotopic product is selected. The net cost is comprehensively characterizing the sum total of capital costs for manufacturing the products as well as determining the choice of the most effective directions for capital investments and rational limits of improvement of the products quality. The method is based on main representations of the cascade theory, such as the ideal flow profile and form efficiency as well as mathematical model of the packed column specifying the bonds between its geometric and operating parameters. As a result, the isotopic products cost function could be bound with such parameters as the equilibrium stage height, ultimate packing capacity, its element dimensions, column diameter. It is concluded that the suggested approach to the optimization of isotope separation processes is rather a general one. It permits to solve a number of special problems, such as estimation of advisability of using heat-pump circuits and determining the rational automation level. Besides, by means of the method suggested one can optimize the process conditions with regard to temperature and pressure

  17. Isotopes accumulation in the thermal column of TRIGA reactor

    International Nuclear Information System (INIS)

    Iorgulis, C.; Diaconu, D.; Gugiu, D.; Csaba, R.

    2013-01-01

    The correlation of impurity observed in the virgin graphite and radionuclide content and activities measured in the irradiated graphite needs to know the irradiated history. This is a challenging process if impurity content and irradiation conditions are not accurately known. This is the case of the irradiated graphite in the thermal column of Institute for Nuclear Research Pitesti (INR)14 MW TRIGA reactor. To overcome incomplete impurity content and the unknown position in the column of the measured irradiated graphite available for characterisation and comparison, a set of preliminary simulations were performed. Following Eu 152 /Eu 154 ration they allowed the estimation of an impurity content and irradiation conditions leading to measured activities. Based on these data the radio-isotope accumulation in different positions in the thermal column was predicted. Modelling performed by INR used advanced prediction packages (e.g. WIMS, MCNP ORIGEN-S from Scale 5) to assess the isotopic content of MTR graphite types with irradiation history specific for a TRIGA research reactor. Some certain calculations points from the column were selected in order to model the burnup and isotopes productions using ORIGEN from SCALE code system. (authors)

  18. Compression Behavior of Confined Columns with High-Volume Fly Ash Concrete

    Directory of Open Access Journals (Sweden)

    Sung-Won Yoo

    2017-01-01

    Full Text Available The use of fly ash in ordinary concrete provides practical benefits to concrete structures, such as a gain in long-term strength, reduced hydration heat, improved resistance to chloride, and enhanced workability. However, few studies with high-volume fly ash (HVFA concrete have been conducted that focus on the structural applications such as a column. Thus, there is a need to promote field applications of HVFA concrete as a sustainable construction material. To this end, this study investigated the compressive behavior of reinforced concrete columns that contain HVFA with a 50 percent replacement rate. Six columns were fabricated for this study. The study variables were the HVFA replacement rate, tied steel ratio, and tie steel spacing. The computed ultimate strength by the American Concrete Institute (ACI code conservatively predicted the measured values, and, thus, the existing equation in the ACI code is feasible for confined RC columns that contain HVFA. In addition, an analysis model was calibrated based on the experimental results and is recommended for predicting the stress-strain relationship of confined reinforced concrete columns that contain HVFA.

  19. Strengthing of Beams and Columns using GFRP Bars

    Science.gov (United States)

    Nayak, C. B.; Tade, M. K.; Thakare, S. B., Dr.

    2017-08-01

    Nowadays infrastructure development is raising its pace. Many reinforced high concrete and masonry buildings are constructed annually around the globe. There are large numbers of structures which deteriorate or become unsafe to use because of changes in use, changes in loading condition, change in the design configuration, inferior building material used or natural calamities. Thus repairing and retrofitting of these structures for safe usage of has a great market. There are several situations in which a civil structure would require strengthening due to lack of strength, stiffness, ductility and durability. Beams, columns may be strengthened in flexure by using GFRP in tension zone. In this present work comparative study will be made with and without GFRP circular bars in a beam and column. An experiment study will be carried out to study the change in the structural behavior of beams & columns with GFRP circular bars of different thickness, varying span to depth ratio.

  20. Varied overstrain injuries of the vertebral column conditioned by evolution

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbach, W.

    1983-08-01

    During physiological growth of the juvenile vertebral column, various stages of stability occur which are characterized by the condition of the marginal rim of the vertebral bodies. If the vertebral juvenile column is overstrained, these variations in stability results in a variety of damage to vertebral bodies and vertebral disks. One of these lesions corresponds to Scheuermann's disease (osteochondrosis of vertebral epiphyses in juveniles). Damage of the vertebral column due to overstrain can occur only if the overstrain is applied in upright position. Since Man alone can damage his vertebral column in upright position (as a result of his evolutionary development), Scheuermann's thesis is confirmed that Scheuermann's disease is confined to Man. Spondylolysis/spondylolisthesis is also a damage caused by overstrain. Here, too, the damage can occur only if the load is exercised in upright position, with the exception of a slanted positioning of the intervertebral components.