  1. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    Science.gov (United States)

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p tricuspid valve regurgitation (mean 2.33 vs 1.3, p tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first

  2. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  3. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  4. Pulmonary valve endocarditis associated to a septal interventricular defect and infundibular and pulmonary valve Stenosis

    International Nuclear Information System (INIS)

    Echeverri, Juan G; Diaz, Alejandro; Jaramillo, Nicolas; Gonzalez, Sergio

    2004-01-01

    Ventricular septal defects generate 10% of all adult congenital cardiopathies. 4% to 8% of patients to whom the defect has not been corrected are in risk of developing endocarditis. Pulmonary valve endocarditis is a rare event (1.5% to 2% of all endocarditis cases) and its mean etiology is intravenous drug abuse. The most frequently isolated microorganism in these cases is staphylococcus aurous. We report a case of pulmonary valve endocarditis associated with ventricular septal defect and valvular and infundibular pulmonary stenosis caused by streptococcus sp. in a patient without past medical history of drug abuse, alcoholism or previous invasive procedures

  5. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  6. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  7. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  8. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  9. Mechanical valve at pulmonary site in adult TOF & absent pulmonary valve

    Directory of Open Access Journals (Sweden)

    Aayush Goyal

    2017-09-01

    Full Text Available Absent pulmonary valve syndrome (APVS is a rare congenital heart disease. Tetralogy of Fallot (TOF with APVS is a rare variation of TOF. These patients are commonly cyanotic at birth. Respiratory complaints predominate due to airway compression by dilated pulmonary arteries. Commonest age of presentation is infancy with anecdotal adult case-reports. Surgical treatment requires establishing unobstructed competent right ventricular outflow tract (RVOT often with monocusp or conduits. We present a novel technique of rendering RVOT competent by implanting a tilting disc mechanical prosthesis in a rare adult TOF with APVS.

  10. Technical modification enabling pulmonary valve-sparing repair of a severely hypoplastic pulmonary annulus in patients with tetralogy of Fallot.

    Science.gov (United States)

    Ito, Hiroki; Ota, Noritaka; Murata, Masaya; Tosaka, Yuko; Ide, Yujiro; Tachi, Maiko; Sugimoto, Ai; Sakamoto, Kisaburo

    2013-06-01

    Although pulmonary valve-sparing repair is preferable for patients with tetralogy of Fallot, the repair of very small pulmonary valves is challenging. The present study evaluates our modification for preserving severely hypoplastic pulmonary valves in patients with tetralogy of Fallot. Sixty-eight consecutive patients who underwent complete repair of a tetralogy of Fallot between 2005 and 2011 were retrospectively reviewed. Patients with pulmonary atresia, absence of a pulmonary valve, atrioventricular septal defect and/or subarterial ventricular septal defect were excluded. There were 19 (28%) patients with a severely hypoplastic pulmonary annulus determined by preoperative echocardiography (z-score -4 group. In the z tetralogy of Fallot could not be applied in all patients, this strategy enabled acceptable growth of the valve annulus, with only mild stenosis during the early to mid-term follow-up. This modification seems to be an option, even for a very small pulmonary valve.

  11. Midterm performance of a novel restorative pulmonary valved conduit: preclinical results

    NARCIS (Netherlands)

    Soliman, Osama I.; Miyazaki, Yosuke; Abdelghani, Mohammad; Brugmans, Marieke; Witsenburg, Maarten; Onuma, Yoshinobu; Cox, Martijn; Serruys, Patrick W.

    2017-01-01

    Aims: The Xeltis bioabsorbable pulmonary valved conduit (XPV), designed to guide functional restoration of patients' own tissue, is potentially more durable than current pulmonary bioprosthetic valves/valved conduits. The aim of this study was to assess the haemodynamic performance of the novel XPV

  12. Outcomes of Pulmonary Valve Replacement for Correction Pulmonary Insufficiency after Primary Repair of Tetralogy of Fallot (TOF)

    OpenAIRE

    Mohammad Abbassi Teshnisi; Aliasghar Moeinipour; Hamid Hoseinikhah; Seyedeh Zahra Aemmi; Shahla Shirin Bahador; Nahid Zirak

    2016-01-01

    Background Total correction of Tetralogy of Fallot (TOF) anomaly in early childhood has been practiced in many centers with good results, but in some of patients after few years sever Pulmonary valve insufficiency occurred. Materials and Methods At a cross- sectional study from January 2015 to January 2016, 10 patients who had history of primary repair of TOF with free pulmonary insufficiency (PI) that underwent of pulmonary valve replacement (PVR) with bioprosthetic valves were evaluated. Re...

  13. Denervation of pulmonary artery during mitral valve surgery in patients with high pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    А. В. Богачев-Прокофьев

    2016-01-01

    Full Text Available Objective. Pulmonary hypertension impairs the mitral valve and often leads to more severe symptoms of heart failure, low exercise tolerance and thus higher rates of morbidity and mortality. The purpose of this study is to evaluate the safety and efficacy of simultaneous radiofrequency ablation of ganglionated plexi of the pulmonary artery in patients with high pulmonary hypertension during mitral valve surgery.Methods. The inclusion criteria were based on patients’ echocardiography/right heart catheterization data. The main criteria were mean pulmonary artery pressure ≥40 mm Hg at rest and a positive reactive test with nitric oxide inhalation. From January 2014 to May 2015, 14 patients underwent radiofrequency denervation of the pulmonary artery in addition to planned mitral valve surgery. Mean patient age was 53.4±7.8 years, with 57.1% of patients being females.Results. Mean cardiopulmonary bypass time was 116±12 minutes, mean cross-clamp time was 95±13 minutes, and mean ablation time amounted to 9.5±3.1 minutes. Pulmonary artery pressure decreased significantly from a mean of 56.5±9.8 mmHg to 32.0±7.3 mmHg immediately after the operation (p<0.001, and to 28.4±5.2 mmHg and 29.7±4.4 mmHg on the first and third days at ICU respectively. Mean ICU stay was 3.1±1.2 days. There were neither early deaths nor specific complications.Conclusions. Simultaneous radiofrequency ablation of pulmonary artery ganglionated plexi when performing mitral valve surgery in patients with pulmonary hypertension is a safe and effective procedure. Further research and long-term follow-up would help to determine whether a decrease in the mean pressure of the pulmonary artery can be interpreted as a clinical advantage.

  14. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  15. Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.

    Science.gov (United States)

    Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D

    2017-08-01

    The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.

  16. Performance and morphology of decellularized pulmonary valves implanted in juvenile sheep.

    Science.gov (United States)

    Quinn, Rachael W; Hilbert, Stephen L; Bert, Arthur A; Drake, Bill W; Bustamante, Julie A; Fenton, Jason E; Moriarty, Sara J; Neighbors, Stacy L; Lofland, Gary K; Hopkins, Richard A

    2011-07-01

    Because of cryopreserved heart valve-mediated immune responses, decellularized allograft valves are an attractive option in children and young adults. The objective of this study was to investigate the performance and morphologic features of decellularized pulmonary valves implanted in the right ventricular outflow tract of juvenile sheep. Right ventricular outflow tract reconstructions in juvenile sheep (160±9 days) using cryopreserved pulmonary allografts (n=6), porcine aortic root bioprostheses (n=4), or detergent/enzyme-decellularized pulmonary allografts (n=8) were performed. Valve performance (echocardiography) and morphologic features (gross, radiographic, and histologic examination) were evaluated 20 weeks after implantation. Decellularization reduced DNA in valve cusps by 99.3%. Bioprosthetic valves had the largest peak and mean gradients versus decellularized valves (p=0.03; p<0.001) and cryopreserved valves (p=0.01; p=0.001), which were similar (p=0.45; p=0.40). Regurgitation was minimal and similar for all groups (p=0.16). No cusp calcification was observed in any valve type. Arterial wall calcification was present in cryopreserved and bioprosthetic grafts but not in decellularized valves. No autologous recellularization or inflammation occurred in bioprostheses, whereas cellularity progressively decreased in cryopreserved grafts. Autologous recellularization was present in decellularized arterial walls and variably extending into the cusps. Cryopreserved and decellularized graft hemodynamic performance was comparable. Autologous recellularization of the decellularized pulmonary arterial wall was consistently observed, with variable cusp recellularization. As demonstrated in this study, decellularized allograft valves have the potential for autologous recellularization. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.

    Science.gov (United States)

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki

    2016-08-01

    The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.

  18. Pulmonary abnormalities in mitral valve disease. Comparison between pulmonary wedge pressure, regional pulmonary blood flow and chest films

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, L H; Andersen, Jr, P E [Odense Univ. (Denmark)

    1978-01-01

    Chest films, right sided heart catheterization, and measurement of the regional lung perfusion, using /sup 133/Xe, were carried out 31 times on patients with mitral valve disease. A relationship was found between the radiologic evaluation in 3 grades, and the values of pulmonary wedge pressure and the apical and basal perfusion. Changes in flow distribution as reflected in altered appearance of the vessels and the presence of interstitial edema were found to be the most sensitive factors in the evaluation of pulmonary wedge pressure. Chest radiography was thus found suitable for the evaluation of pulmonary wedge pressure in mitral valve disease.

  19. Unusual right ventricle aneurysm and dysplastic pulmonary valve with mitral valve hypoplasia

    Directory of Open Access Journals (Sweden)

    Ozge Pamukcu

    2013-01-01

    Full Text Available We report a newborn with an unusual combination of aneurysmally dilated thin-walled right ventricle with hypertrophy of the apical muscles of the right ventricle. There was narrow pulmonary annulus, pulmonary regurgitation, and hypoplasia of the mitral valve and left ventricle. We propose that this heart represents a partial form of Uhl`s anomaly.

  20. Transcatheter Pulmonary Valve Replacement: Current State of Art.

    Science.gov (United States)

    Alkashkari, Wail; Alsubei, Amani; Hijazi, Ziyad M

    2018-03-15

    The past couple of decades have brought tremendous advances to the field of pediatric and adult congenital heart disease (CHD). Percutaneous valve interventions are now a cornerstone of not just the congenital cardiologist treating patients with congenital heart disease, but also-and numerically more importantly-for adult interventional cardiologists treating patients with acquired heart valve disease. Transcatheter pulmonary valve replacement (tPVR) is one of the most exciting recent developments in the treatment of CHD and has evolved to become an attractive alternative to surgery in patients with right ventricular outflow tract (RVOT) dysfunction. This review aims to summarize (1) the current state of the art for tPVR, (2) the expanding indications, and (3) the technological obstacles to optimizing tPVR. Since its introduction in 2000, more than ten thousands tPVR procedures have been performed worldwide. Although the indications for tPVR have been adapted earlier from those accepted for surgical intervention, they remain incompletely defined. The new imaging modalities give better assessment of cardiac anatomy and function and determine candidacy for the procedure. The procedure has been shown to be feasible and safe when performed in patients who received pulmonary conduit and or bioprosthetic valves between the right ventricle and the pulmonary artery. Fewer selected patients post trans-annular patch repair for tetralogy of Fallot may also be candidates for this technology. Size restrictions of the currently available valves limit deployment in the majority of patients post trans-annular patch repair. Newer valves and techniques are being developed that may help such patients. Refinements and further developments of this procedure hold promise for the extension of this technology to other patient populations.

  1. Dysplastic pulmonary valve stenosis associated with unilateral absent first metacarpal: A rare association

    Directory of Open Access Journals (Sweden)

    Ashwin Kodliwadmath

    2017-08-01

    Full Text Available Context: Dysplastic pulmonary valve stenosis is a less common variety of valvular pulmonary stenosis. It is known to be part of Noonan syndrome. Bony hand anomalies in patients of pulmonary stenosis are very rare. Case report: A 50-year-old lady, with no significant past history, presented with slowly progressive breathlessness and fatigue, and had progressed from NYHA class 1 to 2 over 2 years. She had unilateral absent first metacarpal and diagnosed on workup to have dysplastic pulmonary valve stenosis and was treated with balloon valvuloplasty. Conclusion: Dysplastic pulmonary valve stenosis can rarely be associated with bony hand anomalies like absent first metacarpal.

  2. Balloon valvuloplasty in dysplastic pulmonary valve stenosis: immediate and intermediate outcomes

    International Nuclear Information System (INIS)

    Sehar, T.; Qureshi, A.U.; Kazmi, U.; Mehmood, A.

    2015-01-01

    To determine the immediate and intermediate outcome in dysplastic and doming pulmonary valve stenosis in children and to determine various factors associated with unsuccessful outcome. Study Design: An interventional study. Place and Duration of Study: The Children's Hospital, Lahore, Pakistan, from June 2006 to December 2012. Methodology: All patients presenting with severe pulmonary valve stenosis were enrolled in the study. Balloon valvuloplasty was performed on all patients. Successful outcome (residual gradient 75 mmHg was the most significant factor associated with unsuccessful outcome (p 60 mmHg was the only significant factor associated with re-intervention in group A (p=0.001). Conclusion: The results from balloon valvuloplasty in dysplastic pulmonary valve were suboptimal when compared to doming valves. However, it provides a high freedom from re-intervention rate in intermediate follow-up. Intervention at moderate severity can result in better outcome. (author)

  3. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  4. Pulmonary Valve Replacement : Twenty-Six Years of Experience With Mechanical Valvar Prostheses

    NARCIS (Netherlands)

    Freling, Hendrik G.; van Slooten, Ymkje J.; van Melle, Joost P.; Ebels, Tjark; Hoendermis, Elke S.; Berger, Rolf M. F.; Hillege, Hans L.; Waterbolk, Tjalling W.; van Veldhuisen, Dirk J.; Willems, Tineke P.; Pieper, Petronella G.

    BACKGROUND: Although the thromboembolic risk after pulmonary valve replacement (PVR) with mechanical valves is presumed to be high, recent studies suggest promising short-term and mid-term results. However, large studies reporting long-term mortality and valve-related complications are missing.

  5. Unusual case of pulmonary valve atresia | Steyn | SA Journal of ...

    African Journals Online (AJOL)

    We report on a 12-year-old boy with a rare form of pulmonary valve atresia with a ventricular septal defect (VSD) and anomalous origin of the left pulmonary artery arising from the aortic arch. He also has an absent right pulmonary artery, ... severe PHT of the left lung. South African Journal of Radiology Vol. 12 (1) 2008: pp.

  6. Fetal MRI correlates with postnatal CT angiogram assessment of pulmonary anatomy in tetralogy of Fallot with absent pulmonary valve.

    Science.gov (United States)

    Sun, Heather Y; Boe, Justin; Rubesova, Erika; Barth, Richard A; Tacy, Theresa A

    2014-01-01

    In tetralogy of Fallot with absent pulmonary valve, pulmonary stenosis and regurgitation results in significant pulmonary artery dilatation. Branch pulmonary artery dilatation often compresses the tracheobronchial tree, causing fluid trapping in fetal life and air trapping and/or atelectasis after birth. Prenatal diagnosis predicts poor prognosis, which depends on the degree of respiratory insufficiency from airway compromise and lung parenchymal disease after birth. Fetal magnetic resonance imaging (MRI) has been useful in evaluating the effects of congenital lung lesions on lung development and indicating severity of pulmonary hypoplasia. This report is the first demonstrating the utility of fetal MRI in tetralogy of Fallot/absent pulmonary valve patients, which predicted postnatal pulmonary artery size and visualized airway compression and lung parenchymal lesions. The distribution of lobar fluid trapping on fetal MRI correlated with air trapping on postnatal computed tomography angiogram. © 2013 Wiley Periodicals, Inc.

  7. Cardiopulmonary manifestations of isolated pulmonary valve infective endocarditis demonstrated with cardiac CT.

    Science.gov (United States)

    Passen, Edward; Feng, Zekun

    2015-01-01

    Right-sided infective endocarditis involving the pulmonary valve is rare. This pictorial essay discusses the use and findings of cardiac CT combined with delayed chest CT and noncontrast chest CT of pulmonary valve endocarditis. Cardiac CT is able to show the full spectrum of right-sided endocarditis cardiopulmonary features including manifestations that cannot be demonstrated by echocardiography. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. Mitral Valve Replacement with a Pulmonary Autograft in an Infant

    Directory of Open Access Journals (Sweden)

    Yong Ho Jeong

    2018-04-01

    Full Text Available A 76-day-old infant weighing 3.4 kg was referred for surgical intervention for severe mitral valve stenoinsufficiency caused by leaflet fibrosis and calcification. He had experienced a cerebral infarction in the left middle cerebral artery territory, which was deemed attributable to an embolism of a calcified particle from the dysmorphic mitral valve. Because mitral valve replacement using a prosthetic valve was not feasible in this small baby, mitral valve replacement with a pulmonary autograft was performed. After a brief period of extracorporeal membrane oxygenation (ECMO support, he was weaned from ECMO and was discharged home without further cardiovascular complications.

  9. Recurrent acute pulmonary oedema after aortic and mitral valve surgery due to trachea malacia and obstructive sleep apnoea syndrome

    NARCIS (Netherlands)

    Sankatsing, S. U. C.; Hanselaar, W. E. J. J.; van Steenwijk, R. P.; Van der Sloot, J. A. P.; Broekhuis, E.; Kok, W. E. M.

    2008-01-01

    In this report we describe a patient with recurrent episodes of acute pulmonary oedema after aortic and mitral valve surgery. The first episode of pulmonary oedema was caused by mitral valve dysfunction. The second episode of pulmonary oedema was not clearly associated with a mitral valve problem,

  10. Spontaneous Tricuspid Valve Chordal Rupture in Idiopathic Pulmonary Hypertension.

    Science.gov (United States)

    Rodrigues, Ana Clara Tude; Afonso, José E; Cordovil, Adriana; Monaco, Claudia; Piveta, Rafael; Cordovil, Rodrigo; Fischer, Claudio H; Vieira, Marcelo; Lira-Filho, Edgar; Morhy, Samira S

    2016-03-01

    Rupture of tricuspid valve is unusual, occurring mainly in the setting of blunt trauma or endomyocardial biopsy. Spontaneous tricuspid valve chordal rupture is particularly rare. We report herein a case of a patient with severe pulmonary hypertension, on the lung transplantation waiting list, who presented with spontaneous chordal rupture, exacerbation of tricuspid insufficiency and worsening of clinical status. Diagnosis and treatment, along with possible mechanisms for this complication, are discussed. © 2015, Wiley Periodicals, Inc.

  11. Anatomic, histopathologic, and echocardiographic features in a dog with an atypical pulmonary valve stenosis with a fibrous band of tissue and a patent ductus arteriosus.

    Science.gov (United States)

    Yoon, Hakyoung; Kim, Jaehwan; Nahm, Sang-Soep; Eom, Kidong

    2017-07-11

    Congenital pulmonary valve stenosis and patent ductus arteriosus are common congenital heart defects in dogs. However, concurrence of atypical pulmonary valve stenosis and patent ductus arteriosus is uncommon. This report describes the anatomic, histopathologic, and echocardiographic features in a dog with concomitant pulmonary valve stenosis and patent ductus arteriosus with atypical pulmonary valve dysplasia that included a fibrous band of tissue. A 1.5-year-old intact female Chihuahua dog weighing 3.3 kg presented with a continuous grade VI cardiac murmur, poor exercise tolerance, and an intermittent cough. Echocardiography indicated pulmonary valve stenosis, a thickened dysplastic valve without annular hypoplasia, and a type IIA patent ductus arteriosus. The pulmonary valve was thick line-shaped in systole and dome-shaped towards the right ventricular outflow tract in diastole. The dog suffered a fatal cardiac arrest during an attempted balloon pulmonary valvuloplasty. Necropsy revealed pulmonary valve dysplasia, commissural fusion, and incomplete opening and closing of the pulmonary valve because of a fibrous band of tissue causing adhesion between the right ventricular outflow tract and the dysplastic intermediate cusp of the valve. A fibrous band of tissue between the right ventricular outflow track and the pulmonary valve should be considered as a cause of pulmonary valve stenosis. Pulmonary valve stenosis and patent ductus arteriosus can have conflicting effects on diastolic and systolic dysfunction, respectively. Therefore, beta-blockers should always be used carefully, particularly in patients with a heart defect where there is concern about left ventricular systolic function.

  12. Long-term results of percutaneous balloon valvuloplasty in pulmonary valve stenosis in the pediatric population.

    Science.gov (United States)

    Merino-Ingelmo, Raquel; Santos-de Soto, José; Coserria-Sánchez, Félix; Descalzo-Señoran, Alfonso; Valverde-Pérez, Israel

    2014-05-01

    Percutaneous pulmonary valvuloplasty is the preferred interventional procedure for pulmonary valve stenosis. The aim of this study was to evaluate the effectiveness of this technique, assess the factors leading to its success, and determine the long-term results in the pediatric population. The study included 53 patients with pulmonary valve stenosis undergoing percutaneous balloon valvuloplasty between December 1985 and December 2000. Right ventricular size and functional echocardiographic parameters, such as pulmonary regurgitation and residual transvalvular gradient, were assessed during long-term follow-up. Peak-to-peak transvalvular gradient decreased from 74 mmHg [interquartile range, 65-100 mmHg] to 20 mmHg [interquartile range, 14-34 mmHg]. The procedure was unsuccessful in 2 patients (3.77%). The immediate success rate was 73.58%. Follow-up ranged from 10 years to 24 years (median, 15 years). During follow-up, all patients developed late pulmonary regurgitation which was assessed as grade II in 58.4% and grade III in 31.2%. There was only 1 case of long-term restenosis (2.1%). Severe right ventricular dilatation was observed in 27.1% of the patients. None of the patients developed significant right ventricular dysfunction. Pulmonary valve replacement was not required in any of the patients. Percutaneous balloon valvuloplasty is an effective technique in the treatment of pulmonary valve stenosis with good long-term results. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  13. Importance of absent ductus arteriosus in tetralogy of Fallot with absent pulmonary valve syndrome.

    Science.gov (United States)

    Qureshi, Muhammad Yasir; Burkhart, Harold M; Julsrud, Paul; Cetta, Frank

    2014-12-01

    Tetralogy of Fallot without pulmonary valve syndrome is almost always associated with an absent ductus arteriosus. Patients with right aortic arch and retroesophageal left subclavian artery have a vascular ring if the left ductus arteriosus or its remnant and the Kommerell diverticulum are present. We report the cases of 2 infants in whom the role of an absent ductus arteriosus or its remnant is noteworthy. Both patients had a combination of tetralogy of Fallot with absent pulmonary valve syndrome and right aortic arch with retroesophageal left subclavian artery without a vascular ring. The absence of the ductus arteriosus has a role in the pathogenesis of tetralogy of Fallot with absent pulmonary valve syndrome. The absence of a ductus arteriosus in the right aortic arch with retroesophageal left subclavian artery precludes a vascular ring.

  14. Multi-slice computed tomography assessment of bronchial compression with absent pulmonary valve

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yu-Min; Sun, Ai-Min; Wang, Qian; Zhu, Ming; Qiu, Hai-Sheng [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Radiology, Shanghai (China); Jaffe, Richard B. [Primary Children' s Medical Center, Department of Medical Imaging, Salt Lake City, UT (United States); Liu, Jin-Fen [Shanghai Children' s Medical Center, Department of Cardiothoracic Surgery, Shanghai (China); Gao, Wei [Shanghai Children' s Medical Center and Shanghai Jiao Tong University Medical School, Department of Cardiology, Shanghai (China); Berdon, Walter E. [Children' s Hospital of New York, Department of Radiology, New York, NY (United States)

    2014-07-15

    Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon. (orig.)

  15. Left Ventricular Function Improves after Pulmonary Valve Replacement in Patients with Previous Right Ventricular Outflow Tract Reconstruction and Biventricular Dysfunction

    Science.gov (United States)

    Kane, Colin; Kogon, Brian; Pernetz, Maria; McConnell, Michael; Kirshbom, Paul; Rodby, Katherine; Book, Wendy M.

    2011-01-01

    Congenital heart defects that have a component of right ventricular outflow tract obstruction, such as tetralogy of Fallot, are frequently palliated in childhood by disruption of the pulmonary valve. Although this can provide an initial improvement in quality of life, these patients are often left with severe pulmonary valve insufficiency. Over time, this insufficiency can lead to enlargement of the right ventricle and to the deterioration of right ventricular systolic and diastolic function. Pulmonary valve replacement in these patients decreases right ventricular volume overload and improves right ventricular performance. To date, few studies have examined the effects of pulmonary valve replacement on left ventricular function in patients with biventricular dysfunction. We sought to perform such an evaluation. Records of adult patients who had undergone pulmonary valve replacement from January 2003 through November 2006 were analyzed retrospectively. We reviewed preoperative and postoperative echocardiograms and calculated left ventricular function in 38 patients. In the entire cohort, the mean left ventricular ejection fraction increased by a mean of 0.07 after pulmonary valve replacement, which was a statistically significant change (P < 0.01). In patients with preoperative ejection fractions of less than 0.50, mean ejection fractions increased by 0.10. We conclude that pulmonary valve replacement in patients with biventricular dysfunction arising from severe pulmonary insufficiency and right ventricular enlargement can improve left ventricular function. Prospective studies are needed to verify this finding. PMID:21720459

  16. Mechanics of the pulmonary valve in the aortic position

    NARCIS (Netherlands)

    Soares, A.L.F.; Geemen, van D.; Bogaerdt, van den A.J.; Oomens, C.W.J.; Bouten, C.V.C.; Baaijens, F.P.T.

    2014-01-01

    Mathematical models can provide valuable information to assess and evaluate the mechanical behavior and remodeling of native tissue. A relevant example when studying collagen remodeling is the Ross procedure because it involves placing the pulmonary autograft in the more demanding aortic valve

  17. Cardiovascular effects of right ventricle-pulmonary artery valved conduit implantation in experimental pulmonic stenosis

    International Nuclear Information System (INIS)

    Saida, Y.; Tanaka, R.; Fukushima, R.; Hoshi, K.; Hira, S.; Soda, A.; Iizuka, T.; Ishikawa, T.; Nishimura, T.; Yamane, Y.

    2009-01-01

    Right ventricle (RV)-pulmonary artery (PA) valved conduit (RPVC) implantation decreases RV systolic pressure in pulmonic stenosis (PS) by forming a bypass route between the RV and the PA. The present study evaluates valved conduits derived from canine aortae in a canine model of PS produced by pulmonary artery banding (PAB). Pulmonary stenosis was elicited using PAB in 10 conditioned beagles aged 8 months. Twelve weeks after PAB, the dogs were assigned to one group that did not undergo surgical intervention and another that underwent RPVC using denacol-treated canine aortic valved grafts (PAB+RPVC). Twelve weeks later, the rate of change in the RV-PA systolic pressure gradient was significantly decreased in the PAB+RPVC, compared with the PAB group (60.5+-16.7% vs. 108.9+-22.9%; p0.01). In addition, the end-diastolic RV free wall thickness (RVFWd) was significantly reduced in the PAB+RPVC, compared with the PAB group (8.2+-0.2 vs. 9.4+-0.7 mm; p0.05). Thereafter, regurgitation was not evident beyond the conduit valve and the decrease in RV pressure overload induced by RPVC was confirmed. The present results indicate that RPVC can be performed under a beating heart without cardiopulmonary bypass and adapted to dogs with various types of PS, including 'supra valvular' PS or PS accompanied by dysplasia of the pulmonary valve. Therefore, we consider that this method is useful for treating PS in small animals

  18. Outcomes of Pulmonary Valve Replacement for Correction Pulmonary Insufficiency after Primary Repair of Tetralogy of Fallot (TOF

    Directory of Open Access Journals (Sweden)

    Mohammad Abbassi Teshnisi

    2016-09-01

    Full Text Available Background Total correction of Tetralogy of Fallot (TOF anomaly in early childhood has been practiced in many centers with good results, but in some of patients after few years sever Pulmonary valve insufficiency occurred. Materials and Methods At a cross- sectional study from January 2015 to January 2016, 10 patients who had history of primary repair of TOF with free pulmonary insufficiency (PI that underwent of pulmonary valve replacement (PVR with bioprosthetic valves were evaluated. Results Themean age of patients was 6.5 + 0.753 years old (ranged 8-12 years old and male to female ratio was 6/4. The mean of Intensive care unit (ICU stay and Hospital stay was 4.5+ 0.712 days (ranged 3-8 and 11.5+ 0.357 days (ranged 9- 16. Mean of cardiopulmonary bypass time and operation time was 45 + 0.684 min (ranged 32-60 and 83 + 0.317 min (ranged 65-112. In this study we did not find any mortality and ventricular arrhythmia and Heart block. There was only one case (10% with superficial wound infection that was controlled. At 6 months follow up, all of patients were alive, but Echocardiography sign of Right Ventricular (RV failure was present in 2 patients (20% recently. Conclusion Although for Pulmonary insufficiency after primary TOF repair there is controversial in studies, but we had good results of PVR with Bioprosthesis in TOF patients.

  19. Acceptance and introduction of disruptive technologies - simple steps to build a fully functional pulmonary valved stent.

    Science.gov (United States)

    Huber, Christoph H; Marty, Bettina; von Segesser, Ludwig K

    2007-08-01

    Valved stents are new land for cardiac surgeons even though they are being used more frequently by interventional disciplines. This paper presents simple steps to build a patient-specific pulmonary valved stent and its delivery device. The design concept was tested by random participants at a med-tech meeting. The valved stent is constructed by linking an endoprosthetic graft with a valved-jugular-vein. The delivery device is made from a modified 5-ml syringe. Of 72 participants, 66 (92%) built and 60 participants implanted the device successfully into the targeted pulmonary position via a trans-infundibular access.

  20. Optimal elastomeric scaffold leaflet shape for pulmonary heart valve leaflet replacement.

    Science.gov (United States)

    Fan, Rong; Bayoumi, Ahmed S; Chen, Peter; Hobson, Christopher M; Wagner, William R; Mayer, John E; Sacks, Michael S

    2013-02-22

    Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Successful Tricuspid Valve Replacement in a Patient with Severe Pulmonary Arterial Hypertension and Preserved Right Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Jamil A. Aboulhosn

    2009-01-01

    Full Text Available A 56-year-old patient with severe pulmonary hypertension developed severe tricuspid regurgitation, right-sided heart failure, and congestive hepatopathy. She was transferred for possible lung transplant and/or tricuspid valve surgery. Clinical and echocardiographic assessment provided confidence that acute tricuspid valve failure was responsible for the decompensation and that tricuspid valve replacement despite pulmonary hypertension could be performed.

  2. Dual-Source Computed Tomography Evaluation of Children with Congenital Pulmonary Valve Stenosis

    International Nuclear Information System (INIS)

    Sun, Zhanguo; Xu, Wenjian; Huang, Shuran; Chen, Yueqin; Guo, Xiang; Shi, Zhitao

    2016-01-01

    Despite dual-source computed tomography (DSCT) technology has been performed well on adults or infants with heart disease, specific knowledge about children with congenital pulmonary valve stenosis (PS) remained to be established. This original research aimed to establish a professional approach of DSCT performing technology on children and to assess the image quality performed by DSCT to establish a diagnostic evaluation for children with PS. Ninety-eight children with congenital PS referred to affiliated hospital of Jining medical college were recruited from October 2013 to March 2015. Participants were divided into four groups according to different ages (0 - 1, 1 - 3, 3 - 7, 7 - 14), or three groups according to different heart rates (< 90, 90 - 110, > 110). Image quality of pulmonary valves was assessed based on a four-point grading scale (1 - 4 points). Those cases achieving a score of ≥ 3 points were selected for further investigation, which played a critical role in our analysis. Correlation analysis was used to identify the effects of age and heart rate on image quality. Additionally, the results evaluated by DSCT were compared with those evaluated from the operation, further confirming the accuracy of DSCT. Seventy-two cases (73.4%) achieved a score of ≥ 3 points based on pulmonary valve imaging, which were available for further diagnosis. There was a statistically significant difference (P < 0.05) between the four groups except 0 - 1 group and 1 - 3 group, 3 - 7 group and 7 - 14 group, and the image quality of elder group was higher than younger group. Image score was gradually decreased with increased heart rate (F = 19.05, P < 0.01). Heart rate was negatively correlated with pulmonary valve scores (r = -0.391, P < 0.001), while there was no correlation between age and scores (r = 0.185, P = 0.070). The number, shape, commissure, and opening status of pulmonary valves evaluated by DSCT were the same as the results of operation. Heart rate serves a

  3. The Burden of Pulmonary Hypertension in Patients with Degenerative Mitral Valve Disease in Enugu South-East Nigeria: An Echocardiographic Based Study.

    Science.gov (United States)

    Ejim, E C; Oguanobi, N I

    2016-01-01

    Pulmonary hypertension is a common complication of degenerative mitral valve disease, and contributes significantly to both morbidity and mortality. The use of medications for reduction of pulmonary pressure in patients is not a common practice by most physicians in this part of the world because of the absence of data on pulmonary hypertension. The authors set out to find the prevalence of pulmonary hypertension in patients with degenerative mitral valve disease and to determine if there are gender differences in affectation. This will form a basis for future research on the management of pulmonary hypertension in sub-Saharan Africa. The echocardiographic records of 1390 patients carried out over a period of 4 years were retrospectively reviewed. The examinations were done with a Logic 500 MD echocardiographic machine. Tricuspid valve regurgitation velocity above 250 cm/s defined pulmonary hypertension. Data obtained included presence of degenerative mitral valve disease, pulmonary hypertension, age, and gender. A total of 1390 echocardiogram reports done at Conquest Medical Imaging, Enugu, from July 2009 to August 2013 were retrospectively reviewed. Degenerative mitral valve disease was noted in 18.7% of the patients, (259/1390) made up of 149 males and 110 females with a mean age of 68.3 (14.4) years. Pulmonary hypertension was present in 30% of the patients (78/259) and affected males more than females. Pulmonary hypertension is common in patients with degenerative mitral valve disease in Enugu, and affects males more than females.

  4. [Right branch pulmonary artery stenosis with supravalvar aortic stenosis as a complication of Lecompte maneuver for tetralogy of Fallot associated with absent pulmonary valve].

    Science.gov (United States)

    Honda, Yoshihiro; Suzuki, Shoji; Kaga, Shigeaki; Yoshida, Yukiyo; Kimura, Mitsuhiro; Kamiya, Kentaro; Sakakibara, Kenji; Katsu, Masatake

    2015-05-01

    The patient was diagnosed with tetralogy of Fallot associated with absent pulmonary valve syndrome and a low birth weight of 1,912 g. He suffered from respiratory distress on day 14 and received non-invasive positive pressure ventilation. At 5 months of age and 4.1 kg, he underwent intracardiac repair including right ventricular outflow repair with a monocusp patch, patch closure of the ventricular septum defect and right pulmonary transposition to the anterior of the ascending aorta following the Lecompte maneuver for airway decompression. He was subsequently discharged to home and exhibited an uneventful clinical course with non-invasive positive pressure ventilation for 5 months postoperatively. However, right pulmonary artery and supra-aortic stenosis was noted 2 years after the operation. Computed tomography (CT) and angiography showed ascending aorta strangulation by the right pulmonary artery with right ventricular outflow regurgitation. Right pulmonary artery reconstruction using polytetrafluoroethylene graft interposition and repeat right ventricular outflow repair with bicuspid hand-sewn valves was therefore performed;the postoperative course was uneventful. Pre- and post-operative management using non-invasive positive pressure ventilation and airway decompression with pulmonary artery translocation is a useful strategy in patients exhibiting symptomatic tetralogy of Fallot associated with absent pulmonary valve syndrome in the neonatal period.

  5. Significance of lung anomalies in fetuses affected by tetralogy of Fallot with absent pulmonary valve syndrome.

    Science.gov (United States)

    Tenisch, Estelle; Raboisson, Marie-Josée; Rypens, Françoise; Déry, Julie; Grignon, Andrée; Lapierre, Chantale

    2017-11-01

    Tetralogy of Fallot with absent pulmonary valve syndrome is a rare form of tetralogy of Fallot with dilatation of large pulmonary arteries. Prognosis is related to the severity of the cardiac malformation and to bronchial tree compression by dilated pulmonary arteries. This study analyses the prenatal echographic lung appearance in fetuses with tetralogy of Fallot with absent pulmonary valve and discusses its significance. We carried out a retrospective review of fetal and postnatal files of nine fetuses diagnosed with tetralogy of Fallot with absent pulmonary valve syndrome in our institution. Correlations of prenatal ultrasound and cardiac imaging findings were obtained with outcome. Abnormal heterogeneous fetal lung echogenicity was detected in eight cases out of nine, always associated with significant lobar arterial dilatation. This aspect was well correlated with postnatal imaging and outcome in the four neonatal cases. The only fetus with normal lung echogenicity also had lower degree of pulmonary artery dilatation in the series. This study demonstrates that a heterogeneous ultrasound appearance of the fetal lungs can be detected in utero in the most severe cases. This aspect suggests an already significant compression of the fetal bronchial tree by the dilated arteries that may have prognostic implications.

  6. Pulmonary heart valve replacement using stabilized acellular xenogeneic scaffolds; effects of seeding with autologous stem cells

    Directory of Open Access Journals (Sweden)

    Harpa Marius Mihai

    2015-12-01

    Full Text Available Background: We hypothesized that an ideal heart valve replacement would be acellular valve root scaffolds seeded with autologous stem cells. To test this hypothesis, we prepared porcine acellular pulmonary valves, seeded them with autologous adipose derived stem cells (ADSCs and implanted them in sheep and compared them to acellular valves.

  7. Combined usage of inhaled and intravenous milrinone in pulmonary hypertension after heart valve surgery.

    Science.gov (United States)

    Carev, Mladen; Bulat, Cristijan; Karanović, Nenad; Lojpur, Mihajlo; Jercić, Antonio; Nenadić, Denis; Marovih, Zlatko; Husedzinović, Ino; Letica, Dalibor

    2010-09-01

    Secondary pulmonary hypertension is a frequent condition after heart valve surgery. It may significantly complicate the perioperative management and increase patients' morbidity and mortality. The treatment has not been yet completely defined principally because of lack of the selectivity of drugs for the pulmonary vasculature. The usage of inhaled milrinone could be the possible therapeutic option. Inodilator milrinone is commonly used intravenously for patients with pulmonary hypertension and ventricular dysfunction in cardiac surgery. The decrease in systemic vascular resistance frequently necessitates concomitant use of norepinephrine. Pulmonary vasodilators might be more effective and also devoid of potentially dangerous systemic side effects if applied by inhalation, thus acting predominantly on pulmonary circulation. There are only few reports of inhaled milrinone usage in adult post cardiac surgical patients. We reported 2 patients with severe pulmonary hypertension after valve surgery. Because of desperate clinical situation, we decided to use the combination of inhaled and intravenous milrinone. Inhaled milrinone was delivered by means of pneumatic medication nebulizer dissolved with saline in final concentration of 0.5 mg/ml. The nebulizer was attached to the inspiratory limb of the ventilator circuit, just before the Y-piece. We obtained satisfactory reduction in mean pulmonary artery pressure in both patients, and they were successfully extubated and discharged. Although it is a very small sample of patients, we conclude that the combination of inhaled and intravenous milrinone could be an effective treatment of secondary pulmonary hypertension in high-risk cardiac valve surgery patient. The exact indications for inhaled milrinone usage, optimal concentrations for this route, and the beginning and duration of treatment are yet to be determined.

  8. Recent Development in Pulmonary Valve Replacement after Tetralogy of Fallot Repair: The Emergence of Hybrid Approaches

    Directory of Open Access Journals (Sweden)

    Tariq eSuleiman

    2015-06-01

    Full Text Available In the current era approximately 90% of infants born with tetralogy of Fallot (ToF are expected to live beyond 40 years of age making it the fastest growing population amongst patients with congenital heart disease. One of the most common late consequences after repair of ToF, is pulmonary valve regurgitation (PVR. Significant PVR results in progressive dilatation and dysfunction of the right ventricle, decrease in exercise tolerance, arrhythmias, heart failure, and increased risk of sudden death. The conventional approach of dealing with this problem is to perform pulmonary valve replacement using cardiopulmonary bypass (CPB and cardioplegic arrest. However, this approach is associated not only with long operative times but also side effects related to the use of CPB. Development of percutaneous approaches to valve disease is one of the most exciting areas of research and clinical innovation in cardiovascular research. The main development has been that of transcatheter pulmonary valve replacement for the rehabilitation of conduits between the right ventricle and pulmonary artery in patients after surgery for ToF. However, with the percutaneous technique, a limited size of prosthesis can be inserted. Moreover, the technique does not offer the opportunity of treating additional defects that are frequently associated with severe PR, such as pulmonary artery dilatation, and it cannot be used in the significantly dilated native right ventricular outlet tract (RVOT. The advent of the hybrid surgical options for treating cardiac disease has integrated the techniques of interventional cardiology with the techniques of cardiac surgery to provide a form of therapy that combines the respective strengths of both fields.In this review, we present and compare recent advances in procedures to replace the pulmonary valve in patients with ToF presenting with severe PVR and dilated RVOT.

  9. Tricuspid valve endocarditis with pulmonary infarction caused by central venous catheter

    International Nuclear Information System (INIS)

    Grabbe, E.; Guthoff, A.; Hamburg Univ.

    1981-01-01

    Knowledge of common complications of central venous catheters is completed by a case of bacterial tricuspid endocarditis with recurrent pulmonary infarction. This rare, life threatening complication should be considered in differential diagnosis, when in case of central venous catheter sepsis, changing pulmonary infiltrations with pleural effusion as well as different auscultatory findings above the tricuspid valve do occur. The diagnosis can be supported by echocardiographic demonstration of tricuspid vegetations. (orig.) [de

  10. Tricuspid valve endocarditis with pulmonary infarction caused by central venous catheter

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, E; Guthoff, A

    1981-02-01

    Knowledge of common complications of central venous catheters is completed by a case of bacterial tricuspid endocarditis with recurrent pulmonary infarction. This rare, life threatening complication should be considered in differential diagnosis, when in case of central venous catheter sepsis, changing pulmonary infiltrations with pleural effusion as well as different auscultatory findings above the tricuspid valve do occur. The diagnosis can be supported by echocardiographic demonstration of tricuspid vegetations.

  11. Surgical treatment of tetralogy of Fallot with absent pulmonary valve syndrome.

    Science.gov (United States)

    Tanaka, Yuki; Miyamoto, Takashi; Naito, Yuji; Yoshitake, Shuichi

    2016-06-01

    The patient was a 3-month-old girl weighting 3.6 kg, diagnosed with tetralogy of Fallot and absent pulmonary valve syndrome. We surgically repaired the tetralogy of Fallot by patch closure of the ventricular septal defect, right ventricular outflow tract reconstruction using an expanded polytetrafluoroethylene monocusp patch with a bulging sinus, and removal of the bronchial obstruction by anterior translocation of the pulmonary artery using the Lecompte maneuver. © The Author(s) 2015.

  12. Interstage evaluation of homograft-valved right ventricle to pulmonary artery conduits for palliation of hypoplastic left heart syndrome.

    Science.gov (United States)

    Sandeep, Nefthi; Punn, Rajesh; Balasubramanian, Sowmya; Smith, Shea N; Reinhartz, Olaf; Zhang, Yulin; Wright, Gail E; Peng, Lynn F; Wise-Faberowski, Lisa; Hanley, Frank L; McElhinney, Doff B

    2018-04-01

    Palliation of hypoplastic left heart syndrome with a standard nonvalved right ventricle to pulmonary artery conduit results in an inefficient circulation in part due to diastolic regurgitation. A composite right ventricle pulmonary artery conduit with a homograft valve has a hypothetical advantage of reducing regurgitation, but may differ in the propensity for stenosis because of valve remodeling. This retrospective cohort study included 130 patients with hypoplastic left heart syndrome who underwent a modified stage 1 procedure with a right ventricle to pulmonary artery conduit from 2002 to 2015. A composite valved conduit (cryopreserved homograft valve anastomosed to a polytetrafluoroethylene tube) was placed in 100 patients (47 aortic, 32 pulmonary, 13 femoral/saphenous vein, 8 unknown), and a nonvalved conduit was used in 30 patients. Echocardiographic functional parameters were evaluated before and after stage 1 palliation and before the bidirectional Glenn procedure, and interstage interventions were assessed. On competing risk analysis, survival over time was better in the valved conduit group (P = .040), but this difference was no longer significant after adjustment for surgical era. There was no significant difference between groups in the cumulative incidence of bidirectional Glenn completion (P = .15). Patients with a valved conduit underwent more interventions for conduit obstruction in the interstage period, but this difference did not reach significance (P = .16). There were no differences between groups in echocardiographic parameters of right ventricle function at baseline or pre-Glenn. In this cohort of patients with hypoplastic left heart syndrome, inclusion of a valved right ventricle to pulmonary artery conduit was not associated with any difference in survival on adjusted analysis and did not confer an identifiable benefit on right ventricle function. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier

  13. An unusual case of coronary artery compression that did not preclude successful transcatheter pulmonary valve placement.

    Science.gov (United States)

    Schwartz, Matthew C; Felix, Donald; Iacono, Karen; Nykanen, David

    2018-04-16

    During transcatheter pulmonary valve placement, coronary compression observed during simultaneous right ventricular outflow tract angioplasty and coronary angiography typically contraindicates valve implantation. We present a unique patient with tetralogy of Fallot who underwent successful transcatheter Melody valve placement despite coronary compression observed during right ventricular outflow tract balloon angioplasty. © 2018 Wiley Periodicals, Inc.

  14. Unrepaired Tetralogy of Fallot with Absent Pulmonary Valve in a Mildly Symptomatic 16-Year-Old Boy.

    Science.gov (United States)

    Drogalis-Kim, Diana E; Reemtsen, Brian L; Reardon, Leigh Christopher

    2016-12-01

    Absent pulmonary valve is a rare and severe variant seen in only 3% to 6% of patients with tetralogy of Fallot. Fetuses with this combined condition who survive through birth typically need intervention in infancy or early childhood because of respiratory distress, heart failure, or failure to thrive. We describe the unusual case of a mildly symptomatic 16-year-old boy with these conditions who underwent successful primary repair. Our search of the medical literature yielded fewer than 5 cases of tetralogy of Fallot with absent pulmonary valve (or variants with an absent left pulmonary artery) and survival without repair into later adolescence or adulthood.

  15. Transcatheter Pulmonary Valve Replacement for Right Ventricular Outflow Tract Conduit Dysfunction After the Ross Procedure

    DEFF Research Database (Denmark)

    Gillespie, Matthew J; McElhinney, Doff B; Kreutzer, Jacqueline

    2015-01-01

    BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review of databa......BACKGROUND: Right ventricular outflow tract (RVOT) conduit dysfunction is a limitation of the Ross procedure. Transcatheter pulmonary valve replacement (TPVR) could alter the impact of conduit dysfunction and the risk-benefit balance for the Ross procedure. METHODS: Retrospective review....... Of these, 56 (84%) received a Melody valve; in 5 of the 11 patients who did not, the implant was aborted due to concern for coronary artery compression, and 1 implanted patient required emergent surgery for left coronary compression. The RVOT gradient decreased from a median 38 mm Hg to 13.5 mm Hg (p

  16. Percutaneous pulmonary valve implantation in patients with dysfunction of a "native" right ventricular outflow tract - Mid-term results.

    Science.gov (United States)

    Georgiev, Stanimir; Tanase, Daniel; Ewert, Peter; Meierhofer, Christian; Hager, Alfred; von Ohain, Jelena Pabst; Eicken, Andreas

    2018-05-01

    To investigate the feasibility and mid-term results of percutaneous pulmonary valve implantation (PPVI) in patients with conduit free or "native" right ventricular outflow tracts (RVOT). We identified all 18 patients with conduit free or "native" right ventricular outflow tract, who were treated with percutaneous pulmonary valve implantation (PPVI) in our institution. They were divided into two groups - these in whom the central pulmonary artery was used as an anchoring point for the preparation of the landing zone (n=10) for PPVI and these, in whom a pulmonary artery branch was used for this purpose (n=8). PPVI was performed successfully in all patients with significant immediate RVOT gradient and pulmonary regurgitation grade reduction. Four patients had insignificant paravalvular regurgitation. In one patient the valve was explanted after 4months because of bacterial endocarditis. A follow-up of 19 (4-60) months showed sustained good function of the other implanted valves. The MRI indexed right ventricular end diastolic volume significantly decreased from 108(54-174) ml/m 2 before the procedure to 76(60-126) ml/m 2 six months after PPVI, p=0.01. PPVI is feasible with good mid-term results in selected patients with a "native" RVOT without a previously implanted conduit. Creating a stable landing zone with a diameter less than the largest available valve (currently 29mm) is crucial for the technical success of the procedure. Further studies and the development of new devices could widen the indications for this novel treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [POL-PAVTI--Polish report on transcatheter pulmonary artery valve implantation of Melody-Medtronic prosthesis in the first 14 patients in Poland].

    Science.gov (United States)

    Ruzyłło, Witold; Demkow, Marcin; Włodarska, Elzbieta K; Kowalski, Mirosław; Spiewak, Mateusz; Siudalska, Hanna; Wolski, Piotr; Miśko, Jolanta; Hoffman, Piotr; Kusa, Jacek; Szkutnik, Małgorzata; Białkowski, Jacek; Fiszer, Roland; Urbańska, Ewa; Sondergaard, Lars

    2009-10-01

    To assess the early results of the pulmonary artery valve transcatheter implantation (PAVTI) in pts included into POL-PAVTI registry. Detailed medical and economic analyses were performed. Pulmonary artery valve implantation was performed in 14 pts (9 men), aged 16-31 (mean 24.6 +/- 4.8) years, with pulmonary homograft dysfunction after total repair of tetralogy of Fallot (4 pts), pulmonary atresia (2 pts), pulmonary stenosis (1 pt), common arterial trunk type I (1 pt), Ross procedure (3 pts) and TGA - Rastelli operation (3 pts). Eleven pts underwent in the past 2-5 surgical or/and catheter interventions. Indication for PAVTI was based on clinical evaluation and echocardiographic studies. Assessment of morphological and functional features of the right ventricle (RV) and homograft with the use of cardiac magnetic resonance (CMR) was performed in 10 cases. Pulmonary stenosis (max. pulmonary gradient 32-119, mean 72 +/- 28 mmHg) was observed in 13 pts and/or significant pulmonary regurgitation in 10 pts. The procedure was performed in general anesthesia. The deployment of a valved stent in the pulmonary valve position was preceded by a metal stent implantation. Results were evaluated by echocardiography two days after the procedure and one month later. Four patients were evaluated 6 months after procedure. Time of the procedure varied 60-190 (mean 127 +/- 35) min, time of fluoroscopy ranged 12-31 (mean 21 +/- 11) min. PAVTI was successfully performed in all pts without serious complications. Patients were discharged from the hospital 48-293 (mean 120 +/- 71) h after procedure. Significant reduction of pulmonary gradient after the procedure assessed by echocardiography was observed on the second day (20-60, mean 38 +/- 12 mmHg, p < 0.0001) and one month (19-52, mean 34 +/- 9 mmHg, p < 0.0001). Mild pulmonary regurgitation was observed in 2 pts. In 5 pts evaluated 6 months after procedure haemodynamic parameters were unchanged; no late complications were observed

  18. [Percutaneous catheter-based implantation of artificial pulmonary valves in patients with congenital heart defects].

    Science.gov (United States)

    Wyller, Vegard Bruun; Aaberge, Lars; Thaulow, Erik; Døhlen, Gaute

    2011-07-01

    Percutaneous catheter-based implantation of artificial heart valves is a new technique that may supplement surgery and which may be used more in the future. We here report our first experience with implantation of artificial pulmonary valves in children with congenital heart defects. Eligible patients were those with symptoms of heart failure combined with stenosis and/or insufficiency in an established artificial right ventricular outflow tract. The valve was inserted through a catheter from a vein in the groin or neck. Symptoms, echocardiography, invasive measurements and angiography were assessed for evaluation of treatment effect. Our treatment results are reported for the period April 2007-September 2009. Ten patients (seven men and three women, median age 17 years) were assessed. The procedure reduced pressure in the right ventricle (p = 0.008) and resolved the pulmonary insufficiency in all patients. The median time in hospital was two days. No patients had complications that were directly associated with the implantation procedure. One patient developed a pseudoaneurysm in the femoral artery, another had a short-lasting fever two days after the procedure and one patient experienced a stent fracture that required surgery 9 months after the implantation. After 6 months all patients had a reduced pressure gradient in the right ventricular outflow tract (p = 0.008), the pulmonary insufficiency had improved (p = 0.006) and they all reported improval of symptoms. These results persisted for at least 24 months for the four patients who were monitored until then. Percutaneous catheter-based implantation of artificial pulmonary valves improves hemodynamics in the right ventricle of selected patients with congenital heart defects. A randomized controlled study should be undertaken to provide a stronger evidence-base for usefulness of this procedure.

  19. Fresh Autologous Pericardium to Reconstruct the Pulmonary Valve at the Annulus When Tetralogy of Fallot Requires a Transannular Patch at Midterm.

    Science.gov (United States)

    Pande, Shantanu; Sharma, Jugal K; Siddartha, C R; Bansal, Anubhav; Agarwal, Surendra K; Tewari, Prabhat; Kapoor, Aditya

    2016-06-01

    Tetralogy of Fallot often requires reconstruction of the right ventricular outflow tract with a transannular patch (TAP), but this renders the pulmonary valve incompetent and eventually leads to right ventricular dysfunction. We retrospectively evaluated the efficacy of a reconstructed pulmonary valve and annulus in 70 patients who underwent, from December 2006 through December 2010, complete correction of tetralogy of Fallot. We divided the 70 patients into 2 groups in accordance with whether they required (n=50) or did not require (n=20) a TAP. We used autologous untreated pericardium to fashion the TAP and to create both an annulus of the correct size and a competent pulmonary valve with native leaflets. We evaluated the efficiency of this procedure both functionally and anatomically. The median age of the patients was 11 years (range, 2-38 yr). There were 56 males, with no significant difference in sexual distribution between groups. The clinical follow-up was 88% for 57.5 months, and the echocardiographic follow-up was 80% for 36 months. There was no significant difference in outflow gradient or in the occurrence of pulmonary insufficiency between the TAP group (none, 31; mild, 12; moderate, 6; and severe, 1) and the No-TAP group (none, 16; moderate, 2; and severe, 2) (P=0.59). Nor was there any thickening or calcification in the constructed valves. We conclude that pulmonary valves constructed of untreated autologous pericardium performed as well as native valves after total tetralogy of Fallot correction at midterm.

  20. Melody pulmonary valve bacterial endocarditis: experience in four pediatric patients and a review of the literature.

    Science.gov (United States)

    Villafañe, Juan; Baker, George Hamilton; Austin, Erle H; Miller, Stephen; Peng, Lynn; Beekman, Robert

    2014-08-01

    The objectives of this manuscript are two-fold: (a) to describe the clinical characteristics and management of four pediatric patients with bacterial endocarditis (BE) after Melody pulmonary valve implantation (MPVI); and (b) to review the literature regarding Melody pulmonary valve endocarditis. There are several reports of BE following MPVI. The clinical course, BE management and outcome remain poorly defined. This is a multi-center report of four pediatric patients with repaired tetralogy of Fallot (TOF) and BE after MPVI. Clinical presentation, echocardiogram findings, infecting organism, BE management, and follow-up assessment are described. We review available literature on Melody pulmonary valve endocarditis and discuss the prognosis and challenges in the management of these patients. Of our four BE patients, two had documented vegetations and three showed worsening pulmonary stenosis. All patients remain asymptomatic after medical treatment (4) and surgical prosthesis replacement (3) at follow-up of 17 to 40 months. Analysis of published data shows that over half of patients undergo bioprosthesis explantation and that there is a 13% overall mortality. The most common BE pathogens are the Staphylococcus and Streptococcus species. Our case series of four pediatric patients with repaired TOF confirms a risk for BE after MPVI. A high index of suspicion for BE should be observed after MPVI. All patients should be advised to follow lifelong BE prophylaxis after MPVI. In case of BE, surgery should be considered for valve dysfunction or no clinical improvement in spite of medical treatment. © 2014 Wiley Periodicals, Inc.

  1. Pulmonary valve insufficiency in the postoperative out of tetralogy of Fallot: contribution of conventional transthoracic echocardiography for decision making

    International Nuclear Information System (INIS)

    Guzzo de Leon, D.

    2013-01-01

    Pulmonary valve regurgitation is one of the main problems in the late post-op of Tetralogy of F allot, having a great incidence and depending on many aspects . In these paper a review is done considering the usefulness of conventional transtoracic eco cardiography as a tool to evaluate patients with pulmonary regurgitation in the late post-op of Tetralogy of F allot. Main pathophysiologic concepts about these entity are presented, and as a function of that, the most important eco cardiographic parameters to be considered evaluating these patients are also described. Finally guidelines on the opportunity for pulmonary valve replacement are considered

  2. Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.

    Science.gov (United States)

    McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E

    2011-12-01

    Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (Pbioprosthetic valve was associated with lower risk of MSF and reintervention.

  3. VALVE BRONCHIAL BLOCK IN THE INTEGRATED TREATMENT OF BRONCHIAL PLEURAL FISTULAS AFTER SURGICAL REDUCTION OF PULMONARY VOLUME

    Directory of Open Access Journals (Sweden)

    E. A. Tseymakh

    2015-01-01

    Full Text Available Formation of bronchopleural fistulas after surgical reduction of pulmonary volume is one of the most frequent complications of surgical treatment of pulmonary emphysema. In order to control bronchopleural fistulas in the patients after surgical reduction of pulmonary volume the technique of valve bronchial block has been o}ered. This technique has been applied in 7 patients, and the favorable outcomes have been achieved in 6 (85.7% patients. The use of endobronchial valve for occlusion of fistulous bronchi allowed stopping air leaking through drainages, reducing time for pleural cavity drain and decreasing duration of patients' hospital stay.

  4. Mechanical stress is associated with right ventricular response to pulmonary valve replacement in patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Tang, Dalin; Yang, Chun; Del Nido, Pedro J; Zuo, Heng; Rathod, Rahul H; Huang, Xueying; Gooty, Vasu; Tang, Alexander; Billiar, Kristen L; Wu, Zheyang; Geva, Tal

    2016-03-01

    Patients with repaired tetralogy of Fallot account for a substantial proportion of cases with late-onset right ventricular failure. The current surgical approach, which includes pulmonary valve replacement/insertion, has yielded mixed results. Therefore, it may be clinically useful to identify parameters that can be used to predict right ventricular function response to pulmonary valve replacement. Cardiac magnetic resonance data before and 6 months after pulmonary valve replacement were obtained from 16 patients with repaired tetralogy of Fallot (8 male, 8 female; median age, 42.75 years). Right ventricular ejection fraction change from pre- to postpulmonary valve replacement was used as the outcome. The patients were divided into group 1 (n = 8, better outcome) and group 2 (n = 8, worst outcome). Cardiac magnetic resonance-based patient-specific computational right ventricular/left ventricular models were constructed, and right ventricular mechanical stress and strain, wall thickness, curvature, and volumes were obtained for analysis. Our results indicated that right ventricular wall stress was the best single predictor for postpulmonary valve replacement outcome with an area under the receiver operating characteristic curve of 0.819. Mean values of stress, strain, wall thickness, and longitudinal curvature differed significantly between the 2 groups with right ventricular wall stress showing the largest difference. Mean right ventricular stress in group 2 was 103% higher than in group 1. Computational modeling and right ventricular stress may be used as tools to identify right ventricular function response to pulmonary valve replacement. Large-scale clinical studies are needed to validate these preliminary findings. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. Repaired tetralogy of Fallot: the roles of cardiovascular magnetic resonance in evaluating pathophysiology and for pulmonary valve replacement decision support

    Science.gov (United States)

    2011-01-01

    Surgical management of tetralogy of Fallot (TOF) results in anatomic and functional abnormalities in the majority of patients. Although right ventricular volume load due to severe pulmonary regurgitation can be tolerated for many years, there is now evidence that the compensatory mechanisms of the right ventricular myocardium ultimately fail and that if the volume load is not eliminated or reduced by pulmonary valve replacement the dysfunction might be irreversible. Cardiovascular magnetic resonance (CMR) has evolved during the last 2 decades as the reference standard imaging modality to assess the anatomic and functional sequelae in patients with repaired TOF. This article reviews the pathophysiology of chronic right ventricular volume load after TOF repair and the risks and benefits of pulmonary valve replacement. The CMR techniques used to comprehensively evaluate the patient with repaired TOF are reviewed and the role of CMR in supporting clinical decisions regarding pulmonary valve replacement is discussed. PMID:21251297

  6. Single left coronary ostium and an anomalous prepulmonic right coronary artery in 2 dogs with congenital pulmonary valve stenosis.

    Science.gov (United States)

    Visser, Lance C; Scansen, Brian A; Schober, Karsten E

    2013-06-01

    A coronary artery anomaly characterized by the presence of a single left coronary ostium with absence of the right coronary ostium and an anomalous prepulmonic right coronary artery course was observed in two dogs with concurrent congenital pulmonary valve stenosis. This unique coronary artery anatomy is similar to the previously described single right coronary ostium with anomalous prepulmonic left coronary artery, the so-called type R2A anomaly, in that an anomalous coronary artery encircles the pulmonary valve annulus. Both dogs of this report, a boxer and an English bulldog, were of breeds known to be at risk for the type R2A anomaly. As such, veterinarians should be aware that the echocardiographic presence of a left coronary ostium in a dog with pulmonary valve stenosis does not exclude the possibility of a prepulmonic coronary artery anomaly that may enhance the risk of complications during balloon pulmonary valvuloplasty. A descriptive naming convention for coronary artery anomalies in dogs is also presented, which may be preferable to the older coding classification scheme. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Percutaneous pulmonary valve implantation preceded by routine prestenting with a bare metal stent

    DEFF Research Database (Denmark)

    Demkow, Marcin; Biernacka, Elzbieta Katarzyna; Spiewak, Mateusz

    2011-01-01

    Objectives: To evaluate the effectiveness and safety of percutaneous pulmonary valve implantation (PPVI) with routine prestenting with a bare metal stent (BMS). Background: PPVI is a relatively new method of treating patients with repaired congenital heart disease (CHD). Results of PPVI performed.......6 ± 22.7 to 38.8 ± 10.4 mm Hg on the day following implantation (P = 0.001). At 1-month and 6-month follow-ups, mean RVOT gradient was 34.0 ± 9.8 and 32.0 ± 12.2 mm Hg, respectively. In patients with significant pulmonary regurgitation, mean pulmonary regurgitation fraction decreased from 19% ± 6% to 2...

  8. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  9. MRI assessment of bronchial compression in absent pulmonary valve syndrome and review of the syndrome

    International Nuclear Information System (INIS)

    Taragin, Benjamin H.; Berdon, Walter E.; Prinz, B.

    2006-01-01

    Absent pulmonary valve syndrome (APVS) is a rare cardiac malformation with massive pulmonary insufficiency that presents with short-term and long-term respiratory problems secondary to severe bronchial compression from enlarged central and hilar pulmonary arteries. Association with chromosome 22.Q11 deletions and DiGeorge syndrome is common. This historical review illustrates the airway disease with emphasis on assessment of the bronchial compression in patients with persistent respiratory difficulties post-valvular repair. Cases that had MRI for cardiac assessment are used to illustrate the pattern of airway disease. (orig.)

  10. Pulmonary valve replacement in patients with corrected tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Fotios M. Mitropoulos

    2017-06-01

    Results: There were 2 perioperative deaths (2%. One patient developed sternal dehiscence requiring rewiring. Median ICU and hospital stay was 1 and 7 days respectively. Postoperative echocardiography at 6 and 12 months showed excellent bioprosthetic valve performance, significant decrease in size of the right cardiac chambers and reduction of tricuspid regurgitation (TR in the majority of the patients. At mean follow-up of 3.6 ± 2 years, all surviving patients remain in excellent clinical condition. Conclusion: Probability of reoperation for pulmonary insufficiency in patients with surgically corrected TOF increases with time and timely PVR by preventing the development of right heart failure is crucial for long-term survival. Current bioprosthetic valve technology in combination with the beating heart technique provides excellent immediate and short-term results. Further follow-up is necessary to evaluate long-term outcome.

  11. Comparison of valvar and right ventricular function following transcatheter and surgical pulmonary valve replacement.

    Science.gov (United States)

    Li, Wendy F; Pollard, Heidi; Karimi, Mohsen; Asnes, Jeremy D; Hellenbrand, William E; Shabanova, Veronika; Weismann, Constance G

    2018-01-01

    Trans-catheter (TC) pulmonary valve replacement (PVR) has become common practice for patients with right ventricular outflow tract obstruction (RVOTO) and/or pulmonic insufficiency (PI). Our aim was to compare PVR and right ventricular (RV) function of patients who received TC vs surgical PVR. Retrospective review of echocardiograms obtained at three time points: before, immediately after PVR, and most recent. Sixty-two patients (median age 19 years, median follow-up 25 months) following TC (N = 32) or surgical (N = 30) PVR at Yale-New Haven Hospital were included. Pulmonary valve and right ventricular function before, immediately after, and most recently after PVR. At baseline, the TC group had predominant RVOTO (74% vs 10%, P function was good throughout. At last follow-up, the TC group had preserved valve function, but the surgical group did not (moderate RVOTO: 6% vs 41%, P mild PI: 0% vs 24%, P = .003). Patients younger than 17 years at surgical PVR had the highest risk of developing PVR dysfunction, while PVR function in follow-up was similar in adults. Looking at RV size and function, both groups had a decline in RV size following PVR. However, while RV function remained stable in the TC group, there was a transient postoperative decline in the surgical group. TC PVR in patients age function in follow-up compared to surgical valves. There was a transient decline in RV function following surgical but not TC PVR. TC PVR should therefore be the first choice in children who are considered for PVR, whenever possible. © 2017 Wiley Periodicals, Inc.

  12. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    Science.gov (United States)

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Stenting of the right ventricular outflow tract in 2 dogs for palliation of dysplastic pulmonary valve stenosis and right-to-left intracardiac shunting defects.

    Science.gov (United States)

    Scansen, Brian A; Kent, Agnieszka M; Cheatham, Sharon L; Cheatham, John P; Cheatham, John D

    2014-09-01

    Two dogs with severe dysplastic pulmonary valve stenosis and right-to-left shunting defects (patent foramen ovale, perimembranous ventricular septal defect) underwent palliative stenting of the right ventricular outflow tract and pulmonary valve annulus using balloon expandable stents. One dog received 2 over-lapping bare metal stents placed 7 months apart; the other received a single covered stent. Both procedures were considered technically successful with a reduction in the transpulmonary valve pressure gradient from 202 to 90 mmHg in 1 dog and from 168 to 95 mmHg in the other. Clinical signs of exercise intolerance and syncope were temporarily resolved in both dogs. However, progressive right ventricular concentric hypertrophy, recurrent stenosis, and erythrocytosis were observed over the subsequent 6 months leading to poor long-term outcomes. Stenting of the right ventricular outflow tract is feasible in dogs with severe dysplastic pulmonary valve stenosis, though further study and optimization of the procedure is required. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  15. A chronic hemodialysis patient with isolated pulmonary valve infective endocarditis caused by non-albicans Candida: a rare case and literature review.

    Science.gov (United States)

    Chang, Chih-Hao; Huang, Myo-Ming; Yeih, Dong-Feng; Lu, Kuo-Cheng; Hou, Yi-Chou

    2017-09-06

    Isolated pulmonary valve infective endocarditis caused by Candida is rare in chronic hemodialysis patients. The 2009 Infectious Diseases Society of America guidelines suggest the combined use of surgery and antibiotics to treat candidiasis; however, successful nonsurgical treatment of Candida endocarditis has been reported. A 63-year-old woman with end-stage kidney disease was admitted to our hospital after experiencing disorientation for 5 days. The patient was permanently bedridden because of depression, and denied active intravenous drug use. She received maintenance hemodialysis through a tunneled-cuffed catheter. An initial blood culture grew Candida guilliermondii without other bacteria. Subsequent blood cultures and tip culture of tunneled-cuffed catheter also grew C. guilliermondii, even after caspofungin replaced fluconazole. A 1.2-cm mobile mass was observed on the pulmonary valve. Surgical intervention was suggested, but the family of the patient declined because of her multiple comorbidities. The patient was discharged with a prescription of fluconazole, but she died soon after. Our patient is the first case with isolated pulmonary valve endocarditis caused by C. guilliermondii in patients with uremia. Hematologic disorders, in addition to long-term central venous catheter use, prolonged antibiotic intravenous injection, and congenital cardiac anomaly, predispose to the condition. The diagnosis "isolated" pulmonary IE is difficult, and combing surgery with antifungal antibiotics is the appropriate therapeutic management for Candida related pulmonary IE.

  16. Twenty Years of Anesthetic and Perioperative Management of Patients With Tetralogy of Fallot With Absent Pulmonary Valve.

    Science.gov (United States)

    Jochman, John D; Atkinson, Douglas B; Quinonez, Luis G; Brown, Morgan L

    2017-06-01

    Review the authors' institutional experience of the induction and perioperative airway management of children with tetralogy of Fallot with an absent pulmonary valve. Retrospective chart review. Large academic children's hospital. Patients with the diagnosis of tetralogy of Fallot with absent pulmonary valve undergoing primary cardiac repair over a 20-year period. None. Forty-four patients were identified with tetralogy of Fallot with an absent pulmonary valve from January 1995 through August 2014. Forty-two patients (95%) required surgery in their first year of life. Sixteen patients (36%) required mechanical ventilation preoperatively, including 11 neonates. Of the 28 patients not intubated preoperatively, only 1 (3.8%) exhibited minor airway obstruction following induction that was managed uneventfully. All intubations in the operating room were performed in the supine position. Five patients who were mechanically ventilated preoperatively in a lateral or prone position were supinated in the operating room without significant cardiopulmonary compromise. There were no patients who suffered cardiopulmonary arrest or required mechanical circulatory support. The median time to extubation was 2 days (range 1-13 days) in those patients who were not mechanically ventilated prior to their surgery. Ultimately, 5 patients required tracheostomy and 1 patient underwent lobectomy. Although, there was no mortality at 30 days, 4 children died within 1 year of their surgery. All the children who died had a genetic syndrome and required mechanical ventilation preoperatively. While there are theoretical concerns specific to the induction and airway management of tetralogy of Fallot with an absent pulmonary valve, there were no episodes of cardiorespiratory arrest or extracorporeal membrane oxygenation in the authors' series. Neonatal age at the time of surgery, preoperative need for mechanical ventilation, and concomitant genetic syndromes are risk factors for respiratory

  17. Perceived health after percutaneous pulmonary valve implantation: in-depth interviews of patients and next-of-kin

    Science.gov (United States)

    Andresen, Brith; Andersen, Marit Helen; Lindberg, Harald; Døhlen, Gaute; Fosse, Erik

    2014-01-01

    Objective Percutaneous pulmonary valve implantation is an alternative to open heart surgery in selected patients with pulmonary outflow tract disorder. The technique may reduce the number of open-chest surgeries in these patients. This study was conducted to understand how the patients and their next-of-kin experienced this new treatment option. Design Qualitative explorative design with individual in-depth interviews. Setting Oslo University Hospital, the only cardiac centre in Norway offering advanced surgical and interventional treatment to patient with congenital heart defects, serving the whole Norwegian population. Participants During a 2-year period a total of 10 patients, median age 17 (7–30) and 18 next-of-kin were consecutively selected for individual in-depth interviews 3–6 months after the pulmonary valve implantation. The verbatim transcripts were analysed using a phenomenological methodology. Results Patients emphasised the importance of regaining independence and taking control of daily life shortly after the new interventional treatment. Renewed hope towards treatment options was described as ‘a light in the tunnel’. Next-of-kin emphasised the importance both for the patient and their family of resuming normal life quickly after the procedure. The physical burden was experienced as minor after the minimally invasive intervention, compared to their previous experience with surgical procedures. Main outcome measure The importance of maintaining normality in everyday life for a good family function. Conclusions The repeated surgeries during infancy and adolescence of patients with congenital heart disease represent a heavy burden both for the patient and their family. All families especially emphasised the importance of resuming normal life quickly after each procedure. The novel technique of pulmonary valve implantation is thus a favourable approach because of minor interference in daily life. PMID:25079930

  18. Right ventricular remodelling after transcatheter pulmonary valve implantation.

    Science.gov (United States)

    Pagourelias, Efstathios D; Daraban, Ana M; Mada, Razvan O; Duchenne, Jürgen; Mirea, Oana; Cools, Bjorn; Heying, Ruth; Boshoff, Derize; Bogaert, Jan; Budts, Werner; Gewillig, Marc; Voigt, Jens-Uwe

    2017-09-01

    To define the optimal timing for percutaneous pulmonary valve implantation (PPVI) in patients with severe pulmonary regurgitation (PR) after Fallot's Tetralogy (ToF) correction. PPVI among the aforementioned patients is mainly driven by symptoms or by severe right ventricular (RV) dilatation/dysfunction. The optimal timing for PPVI is still disputed. Twenty patients [age 13.9 ± 9.2 years, (range 4.3-44.9), male 70%] with severe PR (≥3 grade) secondary to previous correction of ToF, underwent Melody valve (Medtronic, Minneapolis, MN) implantation, after a pre-stent placement. Full echocardiographic assessment (traditional and deformation analysis) and cardiovascular magnetic resonance evaluation were performed before and at 3 months after the intervention. 'Favorable remodelling' was considered the upper quartile of RV size decrease (>20% in 3 months). After PPVI, indexed RV effective stroke volume increased from 38.4 ± 9.5 to 51.4 ± 10.7 mL/m 2 , (P = 0.005), while RV end-diastolic volume and strain indices decreased (123.1 ± 24.1-101.5 ± 18.3 mL/m 2 , P = 0.005 and -23.5 ± 2.5 to -21 ± 2.5%, P = 0.002, respectively). After inserting pre-PPVI clinical, RV volumetric and deformation parameters in a multiple regression model, only time after last surgical correction causing PR remained as significant regressor of RV remodelling [R 2  = 0.60, beta = 0.387, 95%CI(0.07-0.7), P = 0.019]. Volume reduction and functional improvement were more pronounced in patients treated with PPVI earlier than 7 years after last RV outflow tract (RVOT) correction, reaching close-to-normal values. Early PPVI (<7 years after last RVOT operation) is associated with a more favorable RV reverse remodelling toward normal range and should be considered, before symptoms or RV damage become apparent. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. The CT appearances of delayed amniotic fluid clearance from the lungs in an infant with absent pulmonary valve and congenital lobar emphysema

    International Nuclear Information System (INIS)

    Fink, A. Michelle; Edis, Brian; Massie, John

    2005-01-01

    Congenital lobar emphysema (CLE) is a cause of severe neonatal respiratory distress. Overexpansion of the affected pulmonary lobe in the fetus is due to narrowing of the airway, with a resultant 'ball-valve' effect. At birth, there may be delayed clearance of fetal lung fluid. Early chest radiographs show opacification of the hyperexpanded lobe. The CT findings in the immediate neonatal period have not been previously reported. We describe the imaging in a neonate with tetralogy of Fallot and absent pulmonary valve with secondary CLE. CT demonstrates the hyperexpanded lobe with initial thickening of the interlobular septa and alveolar ground glass attenuation, with subsequent clearing. This resorption of fetal lung fluid via the pulmonary interstitium should not be confused with interstitial lung disease. (orig.)

  20. The CT appearances of delayed amniotic fluid clearance from the lungs in an infant with absent pulmonary valve and congenital lobar emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Fink, A. Michelle [Royal Children' s Hospital, Department of Medical Imaging, Parkville, Victoria (Australia); University of Melbourne, Melbourne, Victoria (Australia); Edis, Brian [Royal Children' s Hospital, Department of Cardiology, Parkville, Victoria (Australia); Massie, John [University of Melbourne, Melbourne, Victoria (Australia); Royal Children' s Hospital, Department of Respiratory Medicine, Parkville, Victoria (Australia); Murdoch Children' s Research Institute, Melbourne, Victoria (Australia)

    2005-09-01

    Congenital lobar emphysema (CLE) is a cause of severe neonatal respiratory distress. Overexpansion of the affected pulmonary lobe in the fetus is due to narrowing of the airway, with a resultant 'ball-valve' effect. At birth, there may be delayed clearance of fetal lung fluid. Early chest radiographs show opacification of the hyperexpanded lobe. The CT findings in the immediate neonatal period have not been previously reported. We describe the imaging in a neonate with tetralogy of Fallot and absent pulmonary valve with secondary CLE. CT demonstrates the hyperexpanded lobe with initial thickening of the interlobular septa and alveolar ground glass attenuation, with subsequent clearing. This resorption of fetal lung fluid via the pulmonary interstitium should not be confused with interstitial lung disease. (orig.)

  1. Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance.

    NARCIS (Netherlands)

    Oosterhof, T.; Straten, A. van; Vliegen, H.W.; Meijboom, F.J.; Dijk, A.P.J. van; Spijkerboer, A.M.; Bouma, B.J.; Zwinderman, A.H.; Hazekamp, M.G.; Roos, A.; Mulder, B.J.M.

    2007-01-01

    BACKGROUND: To facilitate the optimal timing of pulmonary valve replacement, we analyzed preoperative thresholds of right ventricular (RV) volumes above which no decrease or normalization of RV size takes place after surgery. METHODS AND RESULTS: Between 1993 and 2006, 71 adult patients with

  2. Preoperative thresholds for pulmonary valve replacement in patients with corrected tetralogy of Fallot using cardiovascular magnetic resonance

    NARCIS (Netherlands)

    Oosterhof, Thomas; van Straten, Alexander; Vliegen, Hubert W.; Meijboom, Folkert J.; van Dijk, Arie P. J.; Spijkerboer, Anje M.; Bouma, Berto J.; Zwinderman, Aeilko H.; Hazekamp, Mark G.; de Roos, Albert; Mulder, Barbara J. M.

    2007-01-01

    Background - To facilitate the optimal timing of pulmonary valve replacement, we analyzed preoperative thresholds of right ventricular ( RV) volumes above which no decrease or normalization of RV size takes place after surgery. Methods and Results - Between 1993 and 2006, 71 adult patients with

  3. Pulmonary valve stenosis

    Science.gov (United States)

    ... surgery - discharge Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  4. [Tricuspid valve insufficiency: what should be done?].

    Science.gov (United States)

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  5. Triple leaflet perforation due to endocarditis in aortic valve complicated by pneumonia and exacerbation of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Elton Soydan

    2015-09-01

    Full Text Available Valve perforation complicating infective endocarditis has been for decades a bad sign leading to severe valve destruction, intractable heart failure and even death if surgical therapy is not administered in time. Here we present a 57 years old male patient inadvertently diagnosed with pneumonia and chronic obstructive pulmonary disease exacerbation in another hospital. After 20 days of broad spectrum antibiotics and bronchodilator therapy no improvement was achieved. During examination a severe aortic regurgitation was recognized. Immediately after, patient was transferred to our hospital for aortic valve surgery evaluation. Transthorasic echocardiography (TTE showed a severe aortic regurgitation and vegetation like echogenicity over the noncoronary leaflet. An aortic valve replacement surgical therapy was decided. During the aortic valve excision underneath the vegetations, multiple small perforations in all the three leaflets were noticed. The destructed valve was excised and a mechanical aortic prosthesis (St Jude No: 23, MN, USA was successfully replaced. After 14 days of treatment patient was healthily discharged.

  6. Absent pulmonary valve syndrome with intact ventricular septum and patent ductus arteriosus: report of two cases and a short review of the literature.

    NARCIS (Netherlands)

    Grotenhuis, H.B.; Nijveld, A.; Backx, A.P.C.M.

    2003-01-01

    We describe two patients who both presented shortly after birth with congestive heart failure due to an absent pulmonary valve and patent ductus arteriosus. Diagnostic evaluation revealed in both cases an aneurysmatic dilation of the pulmonary vascular tree and an abundant left-to-right shunt over a

  7. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  8. Valve-sparing root replacement for freestanding pulmonary autograft aneurysm after the Ross procedure.

    Science.gov (United States)

    Ratschiller, Thomas; Eva, Sames-Dolzer; Schimetta, Wolfgang; Paulus, Patrick; Müller, Hannes; Zierer, Andreas; Mair, Rudolf

    2018-02-20

    Autograft dilatation is the main long-term complication following the Ross procedure using the freestanding root replacement technique. We reviewed our 25-year experience with the Ross procedure with a special emphasis on valve-sparing reoperations. From 1991 to 2016, 153 patients (29.6 ± 16.6 years; 29.4% pediatric) underwent a Ross operation at our institution with implantation of the autograft as freestanding root replacement. The follow-up is 98.7% complete with a mean of 12.2 ± 5.5 years. Mortality at 30-days was 2.0%. Echocardiography documented no or trivial aortic regurgitation in 99.3% of the patients at discharge. Survival probability at 20 years was 85.4%. No case of autograft endocarditis occurred. Autograft deterioration rate was 2.01% per patient-year, and freedom from autograft reoperation was 75.3% at 15 years. A reoperation for autograft aneurysm was required in 35 patients (22.9%) at a mean interval of 11.1 ± 4.6 years after the Ross procedure. A valve-sparing root replacement was performed in 77% of patients, including 10 David and 17 Yacoub procedures with no early mortality. Three patients required prosthetic valve replacement within 2 years after a Yacoub operation. At latest follow-up, 92% of all surviving patients still carry the pulmonary autograft valve. Freedom from autograft valve replacement was 92.1% at 15 years. Using the David or Yacoub techniques, the autograft valve can be preserved in the majority of patients with root aneurysms after the Ross procedure. Reoperations can be performed with no early mortality, a good functional midterm result, and an acceptable reintervention rate. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. Percutaneous valved stent repair of a failed homograft: implications for the Ross procedure.

    Science.gov (United States)

    Pretorius, Victor; Jones, Alan; Taylor, Dylan; Coe, Yashu; Ross, David B

    2008-08-01

    A case of percutaneous pulmonary valve implantation following a failed homograft in the pulmonary position is reported. A 16-year-old boy developed infective endocarditis of his pulmonary homograft, which was implanted four years earlier during a Ross procedure for congenital aortic stenosis. Following successful medical therapy, the boy was symptomatic due to pulmonary stenosis and regurgitation. A 22 mm Melody valve (Medtronic, USA) was successfully implanted percutaneously. His symptoms resolved and he was discharged home one day after the procedure. Echocardiography at the six-month follow-up demonstrated a normally functioning pulmonary valve. Percutaneous pulmonary valve replacement may make the Ross procedure a more attractive option for patients with aortic stenosis, particularly in the pediatric population.

  10. Percutaneous pulmonary valve replacement after different duration of free pulmonary regurgitation in a porcine model effects on the right and left ventricle

    DEFF Research Database (Denmark)

    Ersboell, Mads; Vejlstrup, Niels; Nilsson, Jens Christian

    2013-01-01

    BACKGROUND: Free pulmonary regurgitation (PR) after surgical correction of Tetralogy of Fallot (ToF) with transannular patching can lead to irreversible right ventricular (RV) failure. However, the optimal timing of valve replacement is still debated. METHODS AND RESULTS: Thirty six pigs were......, respectively) after which PPVR was performed. After 1 month with competent valve the animals were euthanized. Cardiac magnetic resonance (CMR) and right heart catheterization were performed serially. Free PR led to severe dilation of the RV in all three groups compared to matched controls (p.... CONCLUSIONS: Recovery of right ventricular function after free PR by treatment with PPVR was successful in the majority of animals. Increases in RV volume during PR were the only predictor of non-recovery after PPVR and duration of PR did not in itself predict treatment success....

  11. High-pressure balloon valvuloplasty for severe pulmonary valve stenosis: a prospective observational pilot study in 25 dogs.

    Science.gov (United States)

    Belanger, Catherine; Gunther-Harrington, Catherine T; Nishimura, Satoko; Oldach, Maureen S; Fousse, Samantha L; Visser, Lance C; Stern, Joshua A

    2018-04-01

    We aimed to evaluate safety and efficacy of high-pressure balloon valvuloplasty (HPBVP) for treatment of canine severe pulmonary valve stenosis (PS). A secondary aim was to provide pre-procedure predictors of success. Twenty-five dogs. Prospective observational study. Dogs with severe PS (echocardiographically derived trans-pulmonary peak/maximum pressure gradient (EDPG) ≥80 mmHg) were recruited. All dogs underwent echocardiography before and 20-24hrs after HPBVP using a high-pressure balloon with rated burst pressures ranging from 12 to 18 ATM. Procedural success was defined as a post-HPBVP EDPG reduction of ≥50% or reduction into at least the moderate category of PS (50-79 mmHg). Optimal result was defined as a post-procedural EDPG ≤30 mmHg. Initial median (IQR) EDPG for all dogs was 96 (88, 127) mmHg with a post-operative median of 48 (36, 65) mmHg. The median EDPG reduction provided by HPBVP was 63% (39, 68); procedural success rate was 92% (23 dogs). Optimal results were achieved in 56% (14 dogs). There were no significant correlations between EDPG reduction and valve morphology (Type A and Type B) or severity of right ventricular hypertrophy. Pulmonary valve annulus diameter was the only echocardiographic variable that was significantly correlated to EDPG reduction (p = 0.02; r = -0.46). No dog experienced any anesthetic or surgical complications, and all patients survived the procedure. In this cohort of 25 dogs with severe PS, HPBVP was safe and effective. The procedural success rate and high number of optimal results achieved with HPBVP suggest future randomized controlled trials comparing HPBVP to conventional valvuloplasty are warranted. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position

    Science.gov (United States)

    Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.

    2015-01-01

    Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063

  13. Retained fetal lung fluid in two neonates with congenital absence of the pulmonary valve and tetralogy of fallot

    International Nuclear Information System (INIS)

    Strife, J.L.; Towbin, R.B.; Francis, P.; Kuhn, J.P.

    1981-01-01

    Chest radiographs obtained at birth in two neonates with absent pulmonary valve and tetralogy of Fallot demonstrated asymmetrical lung aeration. This finding was attributed to delay in resorption of fetal lung fluid. It is postulated that in the initial hours of life, the dilated pulmonary artery compressed the bronchus and delayed egress of fetal lung fluid. Over a 24-hour interval, the fluid was resorbed, resulting in the more typical pattern of hyperinflated lung and markedly dilated pulmonay artery. These cases are presumably the first of their kind to be reported

  14. Retained fetal lung fluid in two neonates with congenital absence of the pulmonary valve and tetralogy of fallot

    Energy Technology Data Exchange (ETDEWEB)

    Strife, J.L.; Towbin, R.B.; Francis, P.; Kuhn, J.P.

    1981-12-01

    Chest radiographs obtained at birth in two neonates with absent pulmonary valve and tetralogy of Fallot demonstrated asymmetrical lung aeration. This finding was attributed to delay in resorption of fetal lung fluid. It is postulated that in the initial hours of life, the dilated pulmonary artery compressed the bronchus and delayed egress of fetal lung fluid. Over a 24-hour interval, the fluid was resorbed, resulting in the more typical pattern of hyperinflated lung and markedly dilated pulmonay artery. These cases are presumably the first of their kind to be reported.

  15. Diffuse Alveolar Hemorrhage due to Acute Mitral Valve Regurgitation

    Directory of Open Access Journals (Sweden)

    Creticus P. Marak

    2013-01-01

    Full Text Available Diffuse alveolar hemorrhage (DAH can be caused by several etiologies including vasculitis, drug exposure, anticoagulants, infections, mitral valve stenosis, and regurgitation. Chronic mitral valve regurgitation (MR has been well documented as an etiological factor for DAH, but there have been only a few cases which have reported acute mitral valve regurgitation as an etiology of DAH. Acute mitral valve regurgitation can be a life-threatening condition and often requires urgent intervention. In rare cases, acute mitral regurgitation may result in a regurgitant jet which is directed towards the right upper pulmonary vein and may specifically cause right-sided pulmonary edema and right-sided DAH. Surgical repair of the mitral valve results in rapid resolution of DAH. Acute MR should be considered as a possible etiology in patients presenting with unilateral pulmonary edema, hemoptysis, and DAH.

  16. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  17. Early post-operative pulmonary function tests after mitral valve replacement: Minimally invasive versus conventional approach. Which is better?

    Directory of Open Access Journals (Sweden)

    Magdy Gomaa

    2016-12-01

    Conclusion: Minimally invasive right anterolateral mini-thoracotomy is as safe as median sternotomy for mitral valve surgery, with fewer complications and postoperative pain, less ICU and hospital stay, fast recovery to work with no movement restriction after surgery. There was a highly significant difference denoting better post operative pulmonary function of the minimally invasive approach.

  18. Functional pulmonary atresia in newborn with normal intracardiac anatomy: Successful treatment with inhaled nitric oxide and pulmonary vasodilators

    Directory of Open Access Journals (Sweden)

    Gürkan Altun

    2013-01-01

    Full Text Available Functional pulmonary atresia is characterized by a structurally normal pulmonary valve that does not open during right ventricular ejection. It is usually associated with Ebstein′s anomaly, Uhl′s anomaly, neonatal Marfan syndrome and tricuspid valve dysplasia. However, functional pulmonary atresia is rarely reported in newborn with anatomically normal heart. We report a newborn with functional pulmonary atresia who had normal intracardiac anatomy, who responded to treatment with nitric oxide and other vasodilator therapy successfully.

  19. The Impact of Obesity on Postoperative Outcomes in Adults with Congenital Heart Disease Undergoing Pulmonary Valve Replacement.

    Science.gov (United States)

    Buelow, Matthew W; Earing, Michael G; Hill, Garick D; Cohen, Scott B; Bartz, Peter J; Tweddell, James S; Ginde, Salil

    2015-01-01

    The impact of obesity on surgical morbidity in adults with congenital heart disease is currently unknown. The aim of our study was to investigate the impact of obesity on postoperative outcomes in adults with congenital heart disease undergoing reoperation for pulmonary valve replacement. A retrospective analysis was performed assessing the influence of obesity on surgical outcomes. Obesity was defined as a body mass index ≥30 kg/m2. The mean body mass index of the cohort was 25.9 ± 6.9 kg/m2 . The cohort included 71 patients with 17 patients (24%) being obese. There was no postoperative mortality. Obese patients had a longer hospital length of stay (6.6 vs. 4.7 days; P obesity was independently associated with hospital length of stay >5 days (odds ratio [OR] = 5.2; 95% confidence interval [CI]: 1.5-18.2, P = .01) and with increased postoperative arrhythmias (OR = 4.2; 95% CI: 1.7-40, P Obesity is associated with increased morbidity in adults with congenital heart disease undergoing pulmonary valve replacement, including longer hospitalization and higher risk for postoperative arrhythmias. © 2015 Wiley Periodicals, Inc.

  20. Pulmonary arterial pressure and right ventricular dilatation independently determine tricuspid valve insufficiency severity in pre-capillary pulmonary hypertension.

    Science.gov (United States)

    De Meester, Pieter; Van De Bruaene, Alexander; Delcroix, Marion; Belmans, Ann; Herijgers, Paul; Voigt, Jens-Uwe; Budts, Werner

    2012-11-01

    Elevated pulmonary artery systolic pressure (PASP) causes functional tricuspid valve insufficiency (TI). However, the differential contribution of pressure load and right ventricular (RV) dilatation is not well established. The study aim was to evaluate both variables in relation to TI. A cross-sectional study was performed of consecutive transthoracic echocardiographic studies of patients with pre-capillary pulmonary hypertension (PH). Both, demographic data and echocardiographic RV parameters were reviewed. TI was graded semi-quantitatively with color Doppler flow imaging. Trend analyses for TI severity (TI grade 0/4, 1/4, 2/4, 3/4, or 4/4) were performed. A proportional odds logistic regression analysis was carried out to identify independent predictors of TI severity. Eighty-one patients (56 females, 25 males; mean age 60 +/- 15 years) with pre-capillary PH were evaluated. Patients with more severe TI had a significantly lower body mass index, a lower mean systemic blood pressure, a shorter pulmonary acceleration time, a higher tricuspid regurgitant gradient, and a more dilated right ventricle. From the echocardiographic parameters, RV dilatation (p = 0.0143) and the tricuspid regurgitant gradient (p = 0.0026) were independently related to the degree of TI. In patients with pre-capillary PH, PASP and RV dilatation were both related to the increasing severity of TI. When focusing on TI to improve the prognosis of patients with pre-capillary PH, both PASP and RV dimensions should be taken into consideration.

  1. Effects of combined cryopreservation and decellularization on the biomechanical, structural and biochemical properties of porcine pulmonary heart valves.

    Science.gov (United States)

    Theodoridis, Karolina; Müller, Janina; Ramm, Robert; Findeisen, Katja; Andrée, Birgit; Korossis, Sotirios; Haverich, Axel; Hilfiker, Andres

    2016-10-01

    Non-fixed, decellularized allogeneic heart valve scaffolds seem to be the best choice for heart valve replacement, their availability, however, is quite limited. Cryopreservation could prolong their shelf-life, allowing for their ideal match to a recipient. In this study, porcine pulmonary valves were decellularized using detergents, either prior or after cryopreservation, and analyzed. Mechanical integrity was analyzed by uniaxial tensile testing, histoarchitecture by histological staining, and composition by DNA, collagen (hydroxyproline) and GAG (chondroitin sulfate) quantification. Residual sodium dodecyl sulfate (SDS) in the scaffold was quantified by applying a methylene blue activation assay (MBAS). Cryopreserved decellularized scaffolds (DC) and scaffolds that were decellularized after cryopreservation (CD) were compared to fresh valves (F), cryopreserved native valves (C), and decellularized only scaffolds (D). The E-modulus and tensile strength of decellularized (D) tissue showed no significant difference compared to DC and CD. The decellularization resulted in an overall reduction of DNA and GAG, with DC containing the lowest amount of GAGs. The DNA content in the valvular wall of the CD group was higher than in the D and DC groups. CD valves showed slightly more residual SDS than DC valves, which might be harmful to recipient cells. In conclusion, cryopreservation after decellularization was shown to be preferable over cryopreservation before decellularization. However, in vivo testing would be necessary to determine whether these differences are significant in biocompatibility or immunogenicity of the scaffolds. Absence of adverse effects on biomechanical stability of acellular heart valve grafts by cryopreservation, neither before nor after decellularization, allows the identification of best matching patients in a less time pressure dictated process, and therefore to an optimized use of a very limited, but best-suited heart valve prosthesis

  2. Regional pulmonary edema caused by acute mitral insufficiency after rupture of chordae tendinae with prolaps of the posterior mitral valve

    International Nuclear Information System (INIS)

    Mauser, M.; Wiedemer, B.; Fleischmann, D.; Billmann, P.; Ennker, J.

    2003-01-01

    An unilateral or predominantly lobar pulmonary edema is an unusual clinical or radiological finding, often misdiagnosed as one of the more common causes of focal lung disease. We report 2 cases of a regional pulmonary edema caused by the acute onset of a severe mitral insufficiency after the rupture of chordae tendinae resulting in a prolaps of the posterior mitral leaflet. In both cases the regional pulmonary edema was initially misdiagnosed as a pneumonic infiltration, which delayed the cardiological diagnostical procedures and the surgical intervention. The mechanism of the regional edema is an excentric regurgitation jet into the left atrium, which is usually directed to the orifice of the right upper lobe pulmonary vein which increases the hydrostatic vascular pressure in the corresponding lung segment. For the confirmation of the diagnosis, transesophageal echogradiographye is helpful in documenting the direction of the regurgitant flow and detecting differential gradients between the right and left pulmonary venous systems. The pulmonary infiltrations, which persisted for several weeks, dissappeared within a few days after surgical mitral-valve-reconstruction in both cases. (orig.) [de

  3. Histological study of right ventricle-pulmonary artery valved conduit implantation (RPVC) in dogs with pulmonic stenosis.

    Science.gov (United States)

    Saida, Yuuto; Tanaka, Ryou; Fukushima, Ryuji; Hira, Satoshi; Hoshi, Katsuichiro; Soda, Aiko; Iizuka, Tomoya; Ishikawa, Taisuke; Nishimura, Taiki; Yamane, Yoshihisa

    2009-04-01

    We examined whether right ventricle-pulmonary artery valved conduit (RPVC) implantation can overcome the disadvantages of current procedures for pulmonic stenosis (PS). We histologically evaluated the feasibility of RPVC using a homograft in PS model dogs. Eight dogs underwent pulmonary artery banding (PAB) and then 12 weeks later were assigned to PAB (n=4) or PAB+RPVC (n=4) groups. Dogs in the PAB group received no treatment throughout the experimental period, whereas the PAB+RPVC group underwent RPVC. At 1 year after PAB, hearts and conduits were explanted from euthanized dogs and histologically evaluated. The ratios (%) of myocardial fibrosis on right ventricle (RV) epicardial, median and endocardial layers were significantly lower in the PAB+RPVC, than in the PAB group. The ratio of myocardial fibrosis on left ventricular (LV) epicardial and endocardial layers were significantly lower in the PAB+RPVC, than in the PAB group. Neo-intimal thickness in the anastomosis areas of the Denacol and PAB+RPVC groups was 42.77 +/- 30.19 and 88.30 +/- 27.24 microm, respectively, with no significant differences between the groups. Calcification and neo- intima hypertrophy were not obvious in the valve area. Immunohistological staining showed that the internal surface of the anastomosis and intermediate areas were positive for endothelial cells. We concluded that RPVC using a bioprosthetic graft can apparently overcome the disadvantages of current procedures for pulmonic stenosis.

  4. Tricuspid valve endocarditis

    Science.gov (United States)

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  5. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    Following the success of transcatheter aortic and pulmonary valve implantation, there is a large interest in transcatheter mitral valve interventions to treat severe mitral regurgitation (MR). With the exception for the MitraClipTM (Abbott, Abbott Park, IL, USA) edge-to-edge leaflet plication...

  6. Pulmonary damage following right ventricular outflow tachycardia ablation in a child: When electroanatomical mapping isn't good enough.

    Science.gov (United States)

    Bansal, Neha; Kobayashi, Daisuke; Karpawich, Peter P

    2017-11-11

    A 14-year-old female was referred for severe pulmonary valve insufficiency after undergoing radiofrequency ablation for a right ventricular outflow tract tachycardia that originated in the proximal pulmonary artery at 10 years of age. Clinical records indicated that ablation was guided solely by electrograms and electroanatomical mapping. Due to myocardial tissue extensions, mapping failed to identify the level of the pulmonary valve annulus, which resulted in delivery of energy on the valve proper and into the pulmonary artery. She developed severe pulmonary valve insufficiency and moderate proximal pulmonary artery stenosis necessitating intravascular stent placement 4 years later with an associated transcatheter valve. Although the nonfluoroscopic approach during ablation has gained wide acceptance for use in children, this report highlights the benefits of adjunctive imaging to identify the precise location of the pulmonary valve when ablation therapy is contemplated in the right ventricle outflow tract. © 2017 Wiley Periodicals, Inc.

  7. Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.

    Science.gov (United States)

    O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel

    2017-03-01

    Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.

  8. Outcomes of pulmonary valve replacement in 170 patients with chronic pulmonary regurgitation after relief of right ventricular outflow tract obstruction: implications for optimal timing of pulmonary valve replacement.

    Science.gov (United States)

    Lee, Cheul; Kim, Yang Min; Lee, Chang-Ha; Kwak, Jae Gun; Park, Chun Soo; Song, Jin Young; Shim, Woo-Sup; Choi, Eun Young; Lee, Sang Yun; Baek, Jae Suk

    2012-09-11

    The objectives of this study were to evaluate outcomes of pulmonary valve replacement (PVR) in patients with chronic pulmonary regurgitation (PR) and to better define the optimal timing of PVR. Although PVR is effective in reducing right ventricular (RV) volume overload in patients with chronic PR, the optimal timing of PVR is not well defined. A total of 170 patients who underwent PVR between January 1998 and March 2011 for chronic PR were retrospectively analyzed. To define the optimal timing of PVR, pre-operative and post-operative cardiac magnetic resonance imaging (MRI) data (n = 67) were analyzed. The median age at the time of PVR was 16.7 years. Follow-up completeness was 95%, and the median follow-up duration was 5.9 years. Overall and event-free survival at 10 years was 98% and 70%, respectively. Post-operative MRI showed significant reduction in RV volumes and significant improvement in biventricular function. Receiver-operating characteristic curve analysis revealed a cutoff value of 168 ml/m(2) for non-normalization of RV end-diastolic volume index (EDVI) and 80 ml/m(2) for RV end-systolic volume index (ESVI). Cutoff values for optimal outcome (normalized RV volumes and function) were 163 ml/m(2) for RV EDVI and 80 ml/m(2) for RV ESVI. Higher pre-operative RV ESVI was identified as a sole independent risk factor for suboptimal outcome. Midterm outcomes of PVR in patients with chronic PR were acceptable. PVR should be considered before RV EDVI exceeds 163 ml/m(2) or RV ESVI exceeds 80 ml/m(2), with more attention to RV ESVI. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Restenosis after balloon valvuloplasty in a dog with pulmonary stenosis.

    Science.gov (United States)

    Sunahara, Hiroshi; Fujii, Yoko; Sugimoto, Keisuke; Aoki, Takuma; Sugahara, Gou; Shirota, Kinji

    2015-01-01

    A two-month-old female Chihuahua was diagnosed as severe pulmonary valvular stenosis (PS). Although balloon valvuloplasty (BV) was successfully performed, restenosis was observed 19 months after the procedure. Euthanasia was chosen due to low output syndrome during the surgical repair attempted when the dog was 5 years old. Postmortem examination revealed markedly thickened pulmonary valve due to the increase of extracellular matrix which might be produced by increased α smooth muscle actin-positive myofibroblasts. The thickening of the valve was associated with restriction of the valve's motion, resulting in restenosis in the present case. This is the first case report documented histopathological and immunohistochemical findings of the restenotic pulmonary valve in dogs with PS after BV.

  10. Tricuspid valve dysplasia with severe tricuspid regurgitation: fetal pulmonary artery size predicts lung viability in the presence of small lung volumes.

    Science.gov (United States)

    Nathan, A T; Marino, B S; Dominguez, T; Tabbutt, S; Nicolson, S; Donaghue, D D; Spray, T L; Rychik, J

    2010-01-01

    Congenital tricuspid valve disease (Ebstein's anomaly, tricuspid valve dysplasia) with severe tricuspid regurgitation and cardiomegaly is associated with poor prognosis. Fetal echocardiography can accurately measure right atrial enlargement, which is associated with a poor prognosis in the fetus with tricuspid valve disease. Fetal lung volumetric assessments have been used in an attempt to predict viability of fetuses using ultrasonogram and prenatal MRI. We describe a fetus with tricuspid dysplasia, severe tricuspid regurgitation, right atrial enlargement and markedly reduced lung volumes. The early gestational onset of cardiomegaly with bilateral lung compression raised the possibility of severe lung hypoplasia with decreased broncho-alveolar development. Use of fetal echocardiography with measurement of pulmonary artery size combined with prenatal MRI scanning of lung volumes resulted in an improved understanding of this anomaly and directed the management strategy towards a successful Fontan circulation. 2010 S. Karger AG, Basel.

  11. Pulmonary Artery Dissection: A Fatal Complication of Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    Chuanchen Zhang

    2016-01-01

    Full Text Available Pulmonary artery dissection is extremely rare but it is a really life-threatening condition when it happens. Most patients die suddenly from major bleeding or tamponade caused by direct rupture into mediastinum or retrograde into the pericardial sac. What we are reporting is a rare case of a 46-year-old female patient whose pulmonary artery dissection involves both the pulmonary valve and right pulmonary artery. The patient had acute chest pain and severe dyspnea, and the diagnosis of pulmonary artery dissection was confirmed by ultrasonography and CT angiography. Moreover, its etiology, clinical manifestations, and management are also discussed in this article.

  12. MECHANISMS OF COUNTERACTING FLAP-VALVE BRONCHIAL OBSTRUCTION IN CASE OF OBSTRUCTIVE PULMONARY EMPHYSEMA

    Directory of Open Access Journals (Sweden)

    K. F. Tetenev

    2015-01-01

    Full Text Available The research goal was to formulate and substantiate the hypothesis explaining support for an expiratory air flow in case of pulmonary emphysema. The research method consisted in comparing the mechanical properties of lungs in practically healthy individuals (37 individuals, mean age – (30.4 ± 1.7 y.o. and COPD patients with pronounced lung emphysema (30 patients, mean age – (52.1 ± 2.3 y.o. as well as those of isolated normal lungs (n = 14 and isolated lungs of patients who died of COPD (n = 5. Pulmo-nary mechanics was studied via the simultaneous measurement of transpulmonary pressure and lung ven-tilation volume. General lung hysteresis and elastic lung hysteresis were calculated. The mechanical properties of isolated lungs were studied using passive ventilation under the Donders bell. The air flow was interrupted in order to measure alveolar pressure and develop an elastic lung hysteresis curve. Pres-sure in the Donders bell was changed by means of a special pump in automatic and manual modes. The research has not revealed any fundamental differences between the mechanical properties of the normal and emphysematous lungs. A minimum increase in the pressure inside the Donders bell over atmospheric pressure used to stop air ejection in both normal and the emphysematous lungs as the result of flap-valve bronchial obstruction. In living beings, air is ejected from lungs with an increase in pressure under the conditions of forced expiration. Pressure increases up to (38.6 ± 2.71 cm H2O in healthy individuals and up to (20.5 ± 1.86 cm H2O in COPD patients. Probably, an expiratory air flow is supported by active expiratory bronchial dilatation that counteracts flap-valve bronchial obstruction. The hypothesis is based on the confirmed ability of the lungs to perform inspiratory actions (in addition to the action of respiratory muscles and the theory of mechanical lung activity.

  13. Trends in pulmonary valve replacement in children and adults with tetralogy of fallot.

    Science.gov (United States)

    O'Byrne, Michael L; Glatz, Andrew C; Mercer-Rosa, Laura; Gillespie, Matthew J; Dori, Yoav; Goldmuntz, Elizabeth; Kawut, Steven; Rome, Jonathan J

    2015-01-01

    Operative correction of tetralogy of Fallot frequently results in pulmonary insufficiency and chronic volume overload, which have been linked to increased risk for adverse outcomes. No consensus recommendations for the timing of pulmonary valve replacement (PVR) exist. The aim of this study was to examine the pattern of PVR in the United States from 2004 to 2012. The Pediatric Health Information Systems database was used to perform an observational study of children and adults ≥10 years of age with diagnoses of tetralogy of Fallot who underwent PVR at 35 centers in the United States from 2004 and 2012, to assess the rate of PVR and the age at which is performed. Mixed-effects multivariate regression was used to account for patient-level covariates and center-level covariance. Additional analyses assessed for trends in cost, hospital length of stay (LOS), intensive care unit LOS, and in-hospital mortality over the study period. In total, 799 subjects at 35 centers underwent PVR over the study period. The number of PVRs performed per year increased significantly over the study period. There was significant between-center heterogeneity in age at PVR (p optimal timing of PVR. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  15. Isolated Pulmonary Infective Endocarditis with Septic Pulmonary Embolism Complicating a Right Ventricular Outflow Tract Obstruction: Scarce and Devious Presentation

    Directory of Open Access Journals (Sweden)

    Abdelrahmen Abdelbar

    2013-01-01

    Full Text Available We present a case of a fifty-three-year-old male who presented with severe sepsis. He had been treated as a pneumonia patient for five months before the admission. Investigations revealed isolated pulmonary valve endocarditis and septic pulmonary embolism in addition to undiagnosed right ventricular outflow tract (RVOT obstruction. The patient underwent surgery for the relief of RVOT obstruction by substantial muscle resection of the RVOT, pulmonary artery embolectomy, pulmonary valve replacement, and reconstruction of RVOT and main pulmonary artery with two separate bovine pericardial patches. He was discharged from our hospital after 6 weeks of intravenous antibiotics. He recovered well on follow-up 16 weeks after discharge. A high-suspicion index is needed to diagnose right-side heart endocarditis. Blood cultures and transesophageal echocardiogram are the key diagnostic tools.

  16. Balloon catheter dilatation for mitral stenosis and severe pulmonary hypertension

    International Nuclear Information System (INIS)

    Wang Manhong

    2002-01-01

    Objective: To determine the safety and efficacy of percutaneous balloon mitral valvuloplasty (PBMV) for patients with mitral stenosis and severe pulmonary hypertension, and to assess the changes in pulmonary systolic pressure during follow-up. Methods: Forty-two patients with rheumatic mitral stenosis and severe pulmonary hypertension (pulmonary systolic pressure > 75 mmHg) underwent PBMV using standard Inoue technique, and the changes in clinical functional status and echo Doppler pulmonary systolic pressure during follow-up were assessed. Results: PBMV was successful in 39 patients. Immediately after the procedure, mitral valve area increased from (0.83 +- 0.12) cm 2 to (1.75 +- 0.11) cm 2 , pulmonary systolic pressure decreased from (85 +- 7) mmHg to (61 +- 13) mmHg (all P < 0.001). Severe mitral regurgitation occurred in 3 patients, one of whom underwent mitral valve replacement. During follow-up (average 6 months), in 39 patients with successful PBMV, the clinical functional status was improved and pulmonary systolic pressure was further decreased despite unchanged mitral valve area. Conclusions: PBMV was safe and effective for patients with mitral stenosis and severe pulmonary hypertension. Clinical functional status was improved and pulmonary systolic pressure was continuously decreased during the short-term follow-up

  17. Solitary pulmonary nodule by pulmonary hematoma under warfarin therapy

    International Nuclear Information System (INIS)

    Scheppach, W.; Kulke, H.; Liebau, G.; Braun, H.; Wuerzburg Univ.

    1983-01-01

    Pulmonary hematoma is a rare cause of a pulmonary nodule. Mostly it results from penetrating or blunt chest injuries. The case of a patient is reported, whose chest X-ray showed a pulmonary nodule suspected of malignancy. This patient was maintained permanently on anticoagulants (warfarin derivates) after cardiac valve replacement with a prosthesis. A definite diagnosis could not be established by non-invasive methods. A needle biopsy of the lung was impracticable because of the location of the pulmonary lesion; an exploratory thoracotomy could not be carried out due to a general indication of nonoperability. Control examinations showed that the pulmonary nodule had vanished completely within four months. In consideration of the patient's clinical situation it can be concluded that the pulmonary lesion was caused by a hematoma of the lung. (orig.) [de

  18. Solitary pulmonary nodule by pulmonary hematoma under warfarin therapy

    Energy Technology Data Exchange (ETDEWEB)

    Scheppach, W.; Kulke, H.; Liebau, G.; Braun, H.

    1983-06-01

    Pulmonary hematoma is a rare cause of a pulmonary nodule. Mostly it results from penetrating or blunt chest injuries. The case of a patient is reported, whose chest X-ray showed a pulmonary nodule suspected of malignancy. This patient was maintained permanently on anticoagulants (warfarin derivates) after cardiac valve replacement with a prosthesis. A definite diagnosis could not be established by non-invasive methods. A needle biopsy of the lung was impracticable because of the location of the pulmonary lesion; an exploratory thoracotomy could not be carried out due to a general indication of nonoperability. Control examinations showed that the pulmonary nodule had vanished completely within four months. In consideration of the patient's clinical situation it can be concluded that the pulmonary lesion was caused by a hematoma of the lung.

  19. Early and mid-term results of autograft rescue by Ross reversal: A one-valve disease need not become a two-valve disease.

    Science.gov (United States)

    Hussain, Syed T; Majdalany, David S; Dunn, Aaron; Stewart, Robert D; Najm, Hani K; Svensson, Lars G; Houghtaling, Penny L; Blackstone, Eugene H; Pettersson, Gösta B

    2018-02-01

    Risk of reoperation and loss of a second native valve are major drawbacks of the Ross operation. Rather than discarding the failed autograft, it can be placed back into the native pulmonary position by "Ross reversal." We review our early and mid-term results with this operation. From 2006 to 2017, 39 patients underwent reoperation for autograft dysfunction. The autograft was successfully rescued in 35 patients: by Ross reversal in 30, David procedure in 4, and autograft repair in 1. Medical records were reviewed for patient characteristics (mean age was 46 ± 13 years, range 18-67 years, and 23 were male), previous operations, indications for reoperation, hospital outcomes, and echocardiographic findings for the 30 patients undergoing successful Ross reversal. Follow-up was 4.1 ± 3.5 years (range 7 months-11 years). Median interval between the original Ross procedure and Ross reversal was 12 years (range 5-19 years). Eight patients also had absolute indications for replacement of the pulmonary allograft. There was no operative mortality. One patient required reoperation for bleeding. Another had an abdominal aorta injury from use of an endoballoon clamp. There was no other major postoperative morbidity, and median postoperative hospital stay was 7.2 days (range 4-41 days). No patient required reoperation during follow-up. Twenty-four patients had acceptable pulmonary valve function, and 6 had clinically well-tolerated moderate or severe pulmonary regurgitation. Ross reversal can be performed with low morbidity and acceptable pulmonary valve function, reducing patient risk of losing 2 native valves when the autograft fails in the aortic position. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  20. Effect of Percutaneous Edge-to-Edge Repair on Mitral Valve Area and Its Association With Pulmonary Hypertension and Outcomes.

    Science.gov (United States)

    Utsunomiya, Hiroto; Itabashi, Yuji; Kobayashi, Sayuki; Rader, Florian; Hussaini, Asma; Makar, Moody; Trento, Alfredo; Siegel, Robert J; Kar, Saibal; Shiota, Takahiro

    2017-08-15

    Percutaneous edge-to-edge repair using the MitraClip system causes reduction in mitral valve area (MVA). However, its clinical impact is not fully elucidated. This study assessed the impact of postprocedural MVA reduction on pulmonary hypertension and outcomes. A total of 92 patients with grades 3 to 4 + mitral regurgitation (MR) who underwent MitraClip therapy were retrospectively reviewed. Using intraprocedural, 3-dimensional transesophageal echocardiography, postprocedural MVA was obtained by 2 optimized planes through the medial and lateral orifices of the repaired valve. MVA was reduced by 60.1% immediately after MitraClip procedure (p <0.001). Postprocedural MVA correlated moderately with mean transmitral pressure gradient (TMPG) in the majority of patients (r = -0.56, p <0.001), but discordance of MVA and TMPG was observed in 40% of patients. In multivariable linear regression analysis, postprocedural MVA ≤1.94 cm 2 was independently associated with a blunted decrease in systolic pulmonary artery pressure at 1-month follow-up (β-estimate -4.63, 95% confidence interval -9.71 to -0.15, p = 0.042). Postprocedural MVA ≤1.94 cm 2 was an independent predictor of all-cause mortality and heart failure hospitalization after MitraClip (hazard ratio 4.28, 95% confidence interval 1.56 to 11.7, p = 0.005) even after adjustment for age, gender, atrial fibrillation, cause of MR, left ventricular systolic function, pre-existing pulmonary hypertension, and residual MR. After further adjustment for TMPG ≥5 mm Hg, postprocedural MVA ≤1.94 cm 2 remained predictive for adverse outcomes (p = 0.048). In conclusion, the intraprocedural assessment of MVA by 3-dimensional transesophageal echocardiography can predict hemodynamic response and postprocedural prognosis after MitraClip therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. [Minor strut fracture of the Björk-Shiley mitral valve].

    Science.gov (United States)

    Sugita, T; Yasuda, R; Watarida, S; Onoe, M; Tabata, R; Mori, A

    1990-06-01

    In May, 1982, a 49-year-old man underwent mitral valve replacement (MVR) in our hospital with a 31 mm Björk-Shiley prosthesis for mitral regurgitation. He had been doing well until his episode of palpitation and dyspnea of sudden onset, and was transferred to our ICU with severe cardiogenic shock in Aug, 1986. Chest X-ray film revealed pulmonary edema and breakage of the valve with migration of the disc and the minor strut of the prosthesis. He was operated upon 5 hours after the onset of his complaints. The minor strut was removed from the left upper pulmonary vein and mitral valve re-replacement was done with a 29 mm Björk-Shiley Monostrut valve. The disc which had dislocated into the abdominal aorta was also recovered on the twenty-third post operative day. His postoperative course was uneventful. Immediate diagnosis and subsequent re-operation is absolute indication for rescue from acute cardiac failure due to mechanical failure of any prosthetic valve.

  2. Noninvasive predictors of perioperative atrial arrhythmias in patients with tetralogy of Fallot undergoing pulmonary valve replacement.

    Science.gov (United States)

    Cortez, Daniel; Barham, Waseem; Ruckdeschel, Emily; Sharma, Nandita; McCanta, Anthony C; von Alvensleben, Johannes; Sauer, William H; Collins, Kathryn K; Kay, Joseph; Patel, Sonali; Nguyen, Duy T

    2017-08-01

    Patients with tetralogy of Fallot (TOF) have increased risk of atrial arrhythmias. A measure of atrial dispersion, the P-wave vector magnitude (Pvm), can identify patients at risk for perioperative atrial flutter (AFL) or intra-atrial re-entrant tachycardia (IART) in a large TOF cohort. We performed a blinded, retrospective analysis of 158 TOF patients undergoing pulmonary valve replacement between 1997 and 2015. History of AFL/IART was documented using electrocardiogram, Holter monitor, exercise stress test, implanted cardiac device, and electrophysiology study. P-R intervals, Pvm, QRS duration, and QRS vector magnitude were assessed from resting sinus-rhythm 12-lead electrocardiograms and identification of those with AFL/IART was determined. Fourteen patients (8.9%) were found to have AFL/IART. Pvm, QRS duration, and QRS vector magnitude significantly differentiated those with AFL/IART from those without on univariate analysis: 0.09 ± 0.04 vs 0.18 ± 0.07 mV, 161.3 ± 21.9 vs 137.7 ± 31.4 ms, and 1.2 (interquartile range, 1.0-1.2) vs 1.6 mV (1.0-2.3), respectively (P < 0.05 for each). The Pvm had the highest area under the ROC curve (0.88) and was the only significant predictor on multivariate analysis, with odds ratio of 0.02 (95% confidence interval: 0.01-0.53). P-R duration, MRI volumes, and right-heart hemodynamics did not significantly differentiate those with vs those without AFL/IART. In TOF patients undergoing pulmonary valve replacement, Pvm has significant value in predicting those with perioperative AFL/IART. These clinical features may help further evaluate TOF patients at risk for perioperative atrial arrhythmias. Prospective studies are warranted. © 2017 Wiley Periodicals, Inc.

  3. Nova técnica: translocação aórtica e pulmonar com preservação da valva pulmonar New technique: aortic and pulmonary translocation with preservation of pulmonary valve

    Directory of Open Access Journals (Sweden)

    Gláucio Furlanetto

    2010-03-01

    Full Text Available Realizamos com sucesso novo procedimento cirúrgico, em duas crianças portadoras de transposição das grandes artérias associada a comunicação interventricular e obstrução da via de saída do ventrículo esquerdo. A cirurgia consiste na realização de translocação aórtica com a valva aórtica e as artérias coronárias para o ventrículo esquerdo, após a ampliação da via de saída desse ventrículo e da comunicação interventricular com pericárdio autólogo fixado em glutaraldeído, associada à translocação do tronco pulmonar para o ventrículo direito, conservando integralmente a valva pulmonar.We applied successfully, a new surgical technique, in two children with transposition of the great arteries with ventricular septal defect and left ventricular outflow tract obstruction, that utilized aortic translocation with the aortic valve and the coronary arteries to the left ventricle, after correction of left outflow tract obstruction and correction of the ventricular septal defect, associated to pulmonary root translocation to the right ventricle, conserving integrally the pulmonary valve.

  4. Successful management of multiple permanent pacemaker complications – infection, 13 year old silent lead perforation and exteriorisation following failed percutaneous extraction, superior vena cava obstruction, tricuspid valve endocarditis, pulmonary embolism and prosthetic tricuspid valve thrombosis

    Science.gov (United States)

    Kaul, Pankaj; Adluri, Krishna; Javangula, Kalyana; Baig, Wasir

    2009-01-01

    A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis. PMID:19239701

  5. Successful management of multiple permanent pacemaker complications – infection, 13 year old silent lead perforation and exteriorisation following failed percutaneous extraction, superior vena cava obstruction, tricuspid valve endocarditis, pulmonary embolism and prosthetic tricuspid valve thrombosis

    Directory of Open Access Journals (Sweden)

    Javangula Kalyana

    2009-02-01

    Full Text Available Abstract A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis.

  6. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Andrew K. Roy

    2016-01-01

    Full Text Available Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS. Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74, which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure.

  7. Cardioscopic tricuspid valve repair in a beating ovine heart.

    Science.gov (United States)

    Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y

    2009-04-01

    Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.

  8. Infective Endocarditis Complicated by Septic Pulmonary Emboli in a Case of a Ventricular Septal Defect

    Directory of Open Access Journals (Sweden)

    Roodpeyma

    2015-11-01

    Full Text Available Introduction Infective endocarditis (IE causes serious complications in patients. Congenital heart disease (CHD is an important underlying condition in children. Septic pulmonary embolism is an uncommon syndrome, and pulmonary valve IE is rare. The current study presented a case of right-sided IE with pulmonary valve involvement and its complications as pulmonary septic emboli in a child with CHD. Case Presentation A 6-year-old girl with a ventricular septal defect (VSD was presented. Echocardiography revealed large vegetation in the right ventricular outflow tract near the pulmonary valve. The patient showed clinical symptoms of lung involvement, and radiologic investigation was compatible with a diagnosis of septic pulmonary emboli. She had good response to antibacterial therapy and underwent a successful surgical closure of the heart defect. Conclusions Children with CHD are at risk of severe complications with the involvement of other organs. long-term febrile illness should be taken seriously in these children. They need hospitalization and careful evaluation.

  9. Unilateral pulmonary oedema after minimally invasive mitral valve surgery: a single-centre experience.

    Science.gov (United States)

    Renner, Jochen; Lorenzen, Ulf; Borzikowsky, Christoph; Schoeneich, Felix; Cremer, Jochen; Haneya, Assad; Hensler, Johannes; Panholzer, Bernd; Huenges, Katharina; Broch, Ole

    2018-04-01

    Unilateral pulmonary oedema (UPE) is a rare but potentially life-threatening complication that has been described after minimally invasive mitral valve surgery (MICS). Over the last 8 years, we have witnessed, in our institution, several cases of severe UPE requiring immediate postoperative extracorporeal life support after MICS. Reviewing the available literature, data regarding this complication after MICS are rare. Consequently, we decided to retrospectively analyse patients scheduled for MICS in our institution. After approval by our institutional review board, 256 MICS patients were analysed. As a primary end-point, we defined a newly developed UPE, radiographically evident within the first 24 h postoperatively. Secondary end-points were length of stay in the intensive care unit, length of stay in the hospital and in-hospital mortality. Chest radiographs were analysed by an independent consultant of radiology. Fifty-one (19.9%) patients showed increased right-sided pulmonary vascular congestion in the 1st postoperative chest radiography performed in the intensive care unit. Five (1.95%) patients immediately required extracorporeal life support after admission to the intensive care unit. Cardiopulmonary bypass time was significantly longer in the UPE group [UPE vs non-UPE 213 (49) vs 196 (43) min; P = 0.013]. More patients with UPE showed a preoperative increase of C-reactive protein >0.4265 mg/dl (P = 0.05). Logistic regression analysis identified a preoperative increase in C-reactive protein >0.4265 mg/dl as well as a prolonged cardiopulmonary bypass time (odds ratio 1.009, 95% confidence level 1.002-1.016; P = 0.014) independent risk factors, significantly associated with the development of UPE (odds ratio 2.583, 95% confidence interval 1.275-5.233; P = 0.008), a prolonged cardiopulmonary bypass time (odds ratio 1.009, 95% confidence interval 1.002-1.016; P = 0.014). The presence of pulmonary hypertension (odds ratio 0.273, 95

  10. Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.

    Science.gov (United States)

    Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi

    2014-04-15

    Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Clinical implications of hypothermic ventricular fibrillation versus beating-heart technique during cardiopulmonary bypass for pulmonary valve replacement in patients with repaired tetralogy of Fallot.

    Science.gov (United States)

    Lee, Ji-Hyun; Lee, Ji-Eun; Shin, Jungho; Song, In-Kyung; Kim, Hee-Soo; Kim, Chong-Sung; Kim, Woong-Han; Kim, Jin-Tae

    2017-09-01

    This study aimed to compare the effects of hypothermic ventricular fibrillation and beating-heart techniques during cardiopulmonary bypass (CPB) on postoperative outcomes after simple pulmonary valve replacement in patients with repaired tetralogy of Fallot (TOF). We retrospectively reviewed the data of 47 patients with repaired tetralogy of Fallot at a single institution, who received pulmonary valve replacement under the ventricular fibrillation or beating-heart technique without cardioplegic cardiac arrest during CPB between January 2005 and April 2015. The patients were divided into fibrillation (n = 32) and beating-heart (n = 15) groups. On comparing these groups, the fibrillation group had a larger sinotubular junction (27.1 ± 4.6 vs 22.1 ± 2.4 mm), had a longer operation duration (396 ± 108 vs 345 ± 57 min), required more postoperative transfusions (2.1 ± 2.6 vs 5.0 ± 6.3 units) and had a higher vasoactive-inotropic score at intensive care unit admission (8.0 vs 10, all P tetralogy of Fallot. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Experimental assessment of valve performance in healthy and diseased right ventricular outflow tracts using magnetic resonance velocimetry

    Science.gov (United States)

    Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison

    2017-11-01

    Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.

  13. Transcatheter mitral valve implantation via transapical approach

    DEFF Research Database (Denmark)

    Sondergaard, Lars; Brooks, Matthew; Ihlemann, Nikolaj

    2015-01-01

    bypass surgery (n = 2), severe pulmonary hypertension (n = 1) and moderate to severe chronic renal failure (n = 3). A CardiAQ mitral valve was implanted using fluoroscopy and transoesophageal (TEE) guidance via a standard transapical approach. RESULTS: Accurate prosthesis positioning and deployment...

  14. Aorta measurements are heritable and influenced by bicuspid aortic valve

    Directory of Open Access Journals (Sweden)

    Lisa J Martin

    2011-09-01

    Full Text Available Abstract: Word Count 266, 1609 charactersObjectives: To determine whether the contributions of genetics and bicuspid aortic valve (BAV independently influence aortic (Ao dimensions.Background: Ao dilation is a risk factor for aneurysm, dissection, and sudden cardiac death. Frequent association of BAV with Ao dilation implicates a common underlying defect possibly due to genetic factors. Methods: Families enriched for BAV underwent standardized transthoracic echocardiography. In addition to BAV status, echocardiographic measures of Ao (annulus to descending Ao, pulmonary artery and mitral valve annulus diameters were obtained. Using variance components analysis, heritability was estimated with and without BAV status. Additionally, bivariate genetic analyses between Ao dimensions and BAV were performed.Results: Our cohort was obtained from 209 families enriched for BAV. After adjusting for age, body surface area and sex, individuals with BAV had a statistically significant increase in all echocardiographic measurements (p < 0.006 except descending Ao and mitral valve annulus. Individuals with BAV were at greater odds of having Ao dilation (OR = 4.44, 95% CI 2.93 – 6.72 than family members without BAV. All echocardiographic measurements exhibited moderate to strong heritability (0.25 to 0.53, and these estimates were not influenced by inclusion of BAV as a covariate. Bivariate genetic analyses supported that the genetic correlation between BAV and echo measures were not significantly different from zero.Conclusions: We show for the first time that echocardiographic measurements of Ao, pulmonary artery and mitral valve annulus diameters are quantitative traits that exhibit significant heritability. In addition, our results suggest the presence of BAV independently influences the proximal Ao and pulmonary artery measures but not those in the descending Ao or mitral valve annulus.

  15. Monophasic Synovial Sarcoma Presenting as Mitral Valve Obstruction

    Science.gov (United States)

    Chokesuwattanaskul, Warangkana; Terrell, Jason; Jenkins, Leigh Ann

    2010-01-01

    We report the case of a 26-year-old man who experienced progressive left-sided chest pain and 2 episodes of near-syncope. Studies revealed a 15-cm mass in the upper left lung, a 10-cm mass in the medial base of the left lung, and a 5-cm left atrial mass that involved the left lung, infiltrated the left pulmonary vein, and prolapsed into the mitral valve, causing intermittent obstruction. The patient underwent surgical excision of the left atrial tumor. Pathologic evaluation confirmed the diagnosis of monophasic synovial sarcoma. To our knowledge, this is only the 3rd report of left atrial invasion and resultant mitral valve obstruction from a synovial sarcoma that infiltrated the pulmonary vein. We believe that this is the 1st documented case of a metastatic left atrial synovial sarcoma in monophasic form. PMID:20844626

  16. Reversal of echocardiographic right-sided heart pathology in a dog with severe pulmonary hypertension: a case report

    Directory of Open Access Journals (Sweden)

    McMahon P

    2015-06-01

    Full Text Available Peggy McMahon,1 Carley Saelinger 2  1Emergency and Critical Care Department, 2Cardiology Department, Animal Specialty and Emergency Center, Los Angeles, CA, USA Abstract: Pathologic right-sided heart changes are a common echocardiographic finding in patients with pulmonary hypertension (PH. Canines with PH may have right heart pathology documented via echocardiographic color Doppler interrogation including tricuspid valve regurgitation, pulmonic valve insufficiency, elevated pulmonary arterial systolic pressure, elevated pulmonary arterial diastolic pressure, and alterations in ejection profiles. Two-dimensional echocardiographic findings may include right ventricular hypertrophy, interventricular septal flattening, paradoxical interventricular septal motion, pulmonary artery dilation, and potentially abnormal left heart dimensions. In veterinary medicine, much confidence is given to the measurement of pulmonary arterial systolic pressure estimated from tricuspid valve regurgitation to grade the severity of PH and monitor its improvement with little emphasis placed on the integration of two-dimensional echocardiographic right and left heart pathology in conjunction with Doppler findings. To the authors’ knowledge, marked improvement and/or resolution of echocardiographic-documented right heart pathology have not been previously reported in the veterinary literature. This case report documents profound echocardiographic improvement of right-sided heart disease in a dog with severe PH. Keywords: canine, pulmonary hypertension, tricuspid valve regurgitation, right heart hypertrophy, sildenafil  

  17. QRS Width as a Predictor of Right Ventricular Remodeling After Percutaneous Pulmonary Valve Implantation.

    Science.gov (United States)

    Paech, C; Dähnert, I; Riede, F T; Wagner, R; Kister, T; Nieschke, K; Wagner, F; Gebauer, R A

    2017-08-01

    Recent data showed a right ventricular dyssynchrony in patients with tetralogy of Fallot (TOF). Percutaneous pulmonary valve implantation (PPVI) has become an important procedure to treat a pulmonary stenosis and/or regurgitation of the right ventricular outflow tract in these patients. Despite providing good results, there is still a considerable number of nonresponders to PPVI. The authors speculated that electrical dysfunction of the right ventricle plays an underestimated role in the outcome of patients after PPVI. This study aimed to investigate the influence of right ventricular electrical dysfunction, i.e., right bundle branch block (RBBB) on the RV remodeling after PPVI. The study included consecutive patients after correction of TOF with or without RBBB, who had received a PPVI previously at the Heart Center of the University of Leipzig, Germany during the period from 2012 to 2015. 24 patients were included. Patients without RBBB, i.e., with narrow QRS complexes pre-intervention, had significantly better RV function and had smaller right ventricular volumes. Patients with pre-interventionally QRS width below 150 ms showed a post-interventional remodeling of the right ventricle with the decreasing RV volumes (p = 0.001). The parameters of LV function and volume as well as RV ejection fraction remained unaffected by RBBB. The presented data indicate that the QRS width seems to be a valuable parameter in the prediction of right ventricular remodeling after PPVI, as it represents both electrical and mechanical functions of the right ventricle and may serve as an additional parameter for optimal timing of a PPVI.

  18. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  19. Acquired pulmonary artery stenosis in four dogs.

    Science.gov (United States)

    Scansen, Brian A; Schober, Karsten E; Bonagura, John D; Smeak, Daniel D

    2008-04-15

    4 dogs with acquired pulmonary artery stenosis (PAS) were examined for various clinical signs. One was a mixed-breed dog with congenital valvular PAS that subsequently developed peripheral PAS, one was a Golden Retriever with pulmonary valve fibrosarcoma, one was a Pembroke Welsh Corgi in which the left pulmonary artery had inadvertently been ligated during surgery for correction of patent ductus arteriosus, and one was a Boston Terrier with a heart-base mass compressing the pulmonary arteries. All 4 dogs were evaluated with 2-dimensional and Doppler echocardiography to characterize the nature and severity of the stenoses; other diagnostic tests were also performed. The mixed-breed dog with valvular and peripheral PAS was euthanized, surgical resection of the pulmonic valve mass was performed in the Golden Retriever, corrective surgery was performed on the Pembroke Welsh Corgi with left pulmonary artery ligation, and the Boston Terrier with the heart-base mass was managed medically. Acquired PAS in dogs may manifest as a clinically silent heart murmur, syncope, or right-sided heart failure. The diagnosis is made on the basis of imaging findings, particularly results of 2-dimensional and Doppler echocardiography. Treatment may include surgical, interventional, or medical modalities and is targeted at resolving the inciting cause.

  20. Pulmonary Hypertension in Patients With Severe Aortic Stenosis: Prognostic Impact After Transcatheter Aortic Valve Replacement: Pulmonary Hypertension in Patients Undergoing TAVR.

    Science.gov (United States)

    Alushi, Brunilda; Beckhoff, Frederik; Leistner, David; Franz, Marcus; Reinthaler, Markus; Stähli, Barbara E; Morguet, Andreas; Figulla, Hans R; Doenst, Torsten; Maisano, Francesco; Falk, Volkmar; Landmesser, Ulf; Lauten, Alexander

    2018-04-13

    The authors investigated the development of pulmonary hypertension (PH), predictors of PH regression, and its prognostic impact on short, mid-, and long-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS). PH represents a common finding in patients with AS. Although TAVR is frequently associated with regression of PH, the predictors of reversible PH and its prognostic significance remain uncertain. In this study, 617 consecutive patients undergoing TAVR between 2009 and 2015 were stratified per baseline tertiles of pulmonary artery systolic pressure (PASP) as follows: normal (PASP 40% (odds ratio [OR]: 3.56, 95% CI: 2.24 to 5.65; p < 0.001), baseline PASP ≥46 mm Hg (OR: 3.26, 95% CI: 2.07 to 5.12; p < 0.001), absence of concomitant tricuspid regurgitation (TR) ≥ moderate (OR: 0.53, 95% CI: 0.34 to 0.84; p < 0.001), and logistic EuroSCORE <25% (OR: 1.59, 95% CI: 1.04 to 2.45; p = 0.03) were independent predictors of PASP reduction. In most patients with PH and AS, TAVR is associated with a significant early and late reduction of PASP. Patients with reversible PH after TAVR are at lower risk of all-cause mortality at early, mid-, and long-term follow-up. Therefore, the presence of PH should not preclude treatment with TAVR. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Total Anomalous Pulmonary Venous Connection (TAPVC)

    Science.gov (United States)

    ... Ebstein's Anomaly - I-transposition of the great arteries - Patent Ductus Arteriosus (PDA) - Pulmonary Valve Stenosis - Single Ventricle ... Sodium and Salt 3 Heart Attack Symptoms in Women 4 Warning Signs of a Heart Attack 5 ...

  2. A study on the pulmonary mean transit time and the pulmonary blood volume by RI-cardiogram

    International Nuclear Information System (INIS)

    Ushio, Norio

    1987-01-01

    The pulmonary mean transit time and the pulmonary blood volume in cases of cardio-pulmonary disease were measured using Giuntini's method which is considered the most appropriate among radiocardiographic methods. The errors in this method were confirmed to be almost negligible. The results obtained were as follows: 1) The pulmonary mean transit time was related to the systemic mean transit time and markedly prolonged in left heart failure. On the other hand, it was markedly shortened in some cases of chronic pulmonary disease, particularly pulmonary emphysema. 2) The pulmonary blood volume tended to increase in left heart disorders and mitral valve disease and tended to decrease in the chronic pulmonary disease. The decrease was conspicuous particularly in some cases of pulmonary emphysema. 3) A structural change of the pulmonary vascular system in the chronic pulmonary disease appeared to bring about shortening of the pulmonary mean transit time and a decrease in the pulmonary blood volume. The pathophysiology of cardio-pulmonary disease can be more clarified by the RI-cardiogram used in this study, in which the pulmonary mean transit time and the pulmonary blood volume are used as the indicator. (author)

  3. Transapical aortic valve implantation without angiography: proof of concept.

    Science.gov (United States)

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  4. CASE REPORT CASE Unusual case of pulmonary valve atresia

    African Journals Online (AJOL)

    atresia with a ventricular septal defect (VSD) and anomalous origin of the left pulmonary artery arising from ... Anomalous origin of either pulmonary artery branch from the aorta has been reported. The association of ... Department of Radiology, Pretoria Academic Hospital and University of. Pretoria. F Takawira, MB ChB, FC ...

  5. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    Science.gov (United States)

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Right ventricular outflow tract strategies for repair of tetralogy of Fallot: effect of monocusp valve reconstruction.

    NARCIS (Netherlands)

    Sasson, L.; Houri, S.; Raucher Sternfeld, A.; Cohen, I.; Lenczner, O.; Bove, E.L.; Kapusta, L.; Tamir, A.

    2013-01-01

    OBJECTIVES: The absence of a pulmonary valve (PV) after tetralogy of Fallot (TOF) repair has been shown to impact postoperative right ventricular (RV) function. The purposes of this study were to (i) compare early outcomes after PV-sparing vs transannular patching (TAP) with monocusp valve

  7. Isolated pulmonary regurgitation causes decreased right ventricular longitudinal function and compensatory increased septal pumping in a porcine model

    DEFF Research Database (Denmark)

    Kopic, S; Stephensen, S S; Heiberg, E

    2017-01-01

    AIM: Longitudinal ventricular contraction is a parameter of cardiac performance with predictive power. Right ventricular (RV) longitudinal function is impaired in patients with free pulmonary regurgitation (PR) following corrective surgery for Tetralogy of Fallot (TOF). It remains unclear whether...... received a stent in the pulmonary valve orifice, inducing PR. After 2-3 months, animals were subjected to cardiac magnetic resonance imaging. A subset of animals (n = 6) then underwent percutaneous pulmonary valve replacement (PPVR) with follow-up 1 month later. Longitudinal, lateral and septal...

  8. Surgical pathology of excised heart valves in a referral hospital in iran

    International Nuclear Information System (INIS)

    Yaghoubi, A.R.; Raeesi, K.

    2007-01-01

    Assessment of surgical pathology of excised heart valves in a referral hospital in Iran in a five years period. This retrospective descriptive study was done from 2002 to 2005 in Rajaie heart center in Tehran, Iran. Surgery and pathology records of patients who underwent valve replacement or repair surgery were reviewed. Of 1563 patients 738 (47.2%) underwent mitral, 565 (36.1%) aortic, and 215 (14%) multivalve operation. Most common pathology of mitral valve was rheumatic (68%), while degenerative calcific pathology was dominant in aortic valve (52%). Rheumatic involvement was 46%, and degenerative pathology was common in tricuspid and pulmonary valves (50% and 67%, respectively). Time trend analysis shows no significant variation in excised valves pathology or pattern from 2002 to 2005 (p=0.112). Rheumatic pathology in excised heart valves is still common in this referral heart center in Iran, and no obvious change in this pattern was found during a 5 years period. (author)

  9. Tissue properties and collagen remodeling in heart valve tissue engineering

    NARCIS (Netherlands)

    Geemen, van D.

    2012-01-01

    Valvular heart disease is a major health problem worldwide causing morbidity and mortality. Heart valve replacement is frequently applied to avoid serious cardiac, pulmonary, or systemic problems. However, the current replacements do not consist of living tissue and, consequently, cannot grow,

  10. Congenital tricuspid valve disease and testicular agenesis: a case ...

    African Journals Online (AJOL)

    This is a report of a case of congenital tricuspid valve disease presenting with heart failure and pulmonary hypertension. Cardinal clinical features include breathlessness, easy fatigability since childhood, stunted growth, cyanosis, finger clubbing, a pansystolic murmur loudest at the left sternal edge in the fourth intercostal ...

  11. Banking cryopreserved heart valves in Europe: assessment of a 5-year operation in an international tissue bank in Brussels.

    Science.gov (United States)

    Goffin, Y; Grandmougin, D; Van Hoeck, B

    1996-01-01

    The heart valve bank of the European Homograft Bank has been set up in 1988 to meet the growing demand of cardiac surgeons for various sized and quality controlled cryopreserved homografts. Heart valve donors less than 60 years of age were classified in 3 categories: multiorgan donors with non transplantable hearts, recipients of cardiac transplantation and non beating heart cadavers with a warm ischemic time of less than 6 hours. Past history and biology were checked for transmissible diseases. Preparation, progressive freezing and storage in liquid nitrogen vapors, and quality control were according to the standards of the Belgian Ministry of Health. From end January 1989 to end May 1994, 989 homograft valves were cryopreserved (514 pulmonary, 475 aortic and 3 mitral) whereas 962 valves were discarded. The first cause of rejection being a major macroscopic lesion (41.48%). 138 hearts accepted at inspection were contaminated and 43 cases remained so after antibiotics. 38 cases were positive for hepatitis B or C. Complication at distribution and thawing included 10 instances of bag rupture and 15 of transversal fracture through the wall of the conduit. 477 aortic, 474 pulmonary valves as well as one mitral were implanted between May 1989 and May 1994, either for left or right ventricular outflow tract reconstruction. In the left ventricular outflow tract series 111 aortic and 23 pulmonary homograft valves were used in cases of native endocarditis, prosthetic endocarditis or recurrent endocarditis after homograft implantation. 9.6% of the requests could no be satisfied. Regular follow up information was available from 382 implants-40.1% only. The assessment of 5 years operation of the heart valve bank indicates: 1) the efficiency of selecting, cryopreserving and allocating quality controlled homograft valves from a large pool of donor hearts provided by a network of hospitals; 2) the difficulty of obtaining regular follow up information on the implants.

  12. Pulmonary artery dissection following balloon valvuloplasty in a dog with pulmonic stenosis.

    Science.gov (United States)

    Grint, K A; Kellihan, H B

    2017-04-01

    A 3-month-old, 9.9 kg, male pit bull cross was referred for evaluation of collapse. A left basilar systolic heart murmur graded V/VI and a grade IV/VI right basilar systolic heart murmur were ausculted. Echocardiography showed severe pulmonic stenosis characterized by annular hypoplasia, leaflet thickening, and leaflet fusion. After 1 month of atenolol therapy, a pulmonic valve balloon valvuloplasty procedure was performed, and the intra-operative right ventricular pressure was reduced by 43%. Echocardiography, performed the following day, showed apparent rupture of a pulmonary valve leaflet and a membranous structure within the pulmonary artery consistent with a dissecting membrane. Short-term follow-up has shown no apparent progression of the pulmonary artery dissection and the patient remains free of clinical signs. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Pulmonary venous varix associated with mitral regurgitation mimicking a mediastinal mass: A case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Dana AlNuaimi, MD

    2018-04-01

    Full Text Available Pulmonary vein varix is an unusual cause of a mediastinal mass on a chest radiograph. It may be found as an isolated malformation or as a sequela of pulmonary venous hypertension. We encountered a case presenting with left hemiparesis and a past medical history of rheumatic heart disease. The chest radiograph revealed a well-defined mediastinal mass that turned out to be a hugely dilated pulmonary vein on contrast enhanced computed tomography of the chest. The computed tomography of the brain and upper abdomen revealed bilateral cerebral infarction and splenic infarction. In the literature, one-third of the reported cases of pulmonary vein varix are acquired secondary to mitral valve disease. Keywords: Pulmonary venous varix, Mitral valve insufficiency, Cerebral infarction, Splenic infarction, Computed tomography

  14. Ventricular arrhythmia risk stratification in patients with tetralogy of Fallot at the time of pulmonary valve replacement.

    Science.gov (United States)

    Sabate Rotes, Anna; Connolly, Heidi M; Warnes, Carole A; Ammash, Naser M; Phillips, Sabrina D; Dearani, Joseph A; Schaff, Hartzell V; Burkhart, Harold M; Hodge, David O; Asirvatham, Samuel J; McLeod, Christopher J

    2015-02-01

    Most patients with repaired tetralogy of Fallot require pulmonary valve replacement (PVR), but the evaluation for and management of ventricular arrhythmia remain unclear. This study is aimed at clarifying the optimal approach to this potentially life-threatening issue at the time of PVR. A retrospective analysis was performed on 205 patients with repaired tetralogy of Fallot undergoing PVR at our institution between 1988 and 2010. Median age was 32.9 (range, 25.6) years. Previous ventricular tachycardia occurred in 16 patients (8%) and 37 (16%) had left ventricular dysfunction, defined as left ventricular ejection fraction tetralogy of Fallot undergoing PVR with history of ventricular tachycardia or left ventricular dysfunction appear to be associated with a higher risk of arrhythmic events after operation. Events in the first year after PVR are rare, and in select high-risk patients, surgical cryoablation does not seem to increase arrhythmic events and may be protective. © 2014 American Heart Association, Inc.

  15. Leaflet embolisation from Duromedics valves: a report of two cases.

    Science.gov (United States)

    Kumar, N; Balasundaram, S; Rickard, M; al Halees, Z; Duran, C M

    1991-12-01

    Embolization of parts of mechanical valves has been reported since the inception of prosthetic valve implantation. We report here two cases of embolization of one hemileaflet of a Duromedic bileaflet prosthesis in the mitral position due to a pivot fracture. Both presented with moderately severe mitral regurgitation and pulmonary edema and were successfully managed by replacement of the malfunctioning prostheses. The embolised disc was located in the left common iliac artery by abdominal ultrasound and removed by an inguinal, retroperitoneal approach with low morbidity. Both patients left hospital and are doing well to-date.

  16. Septic Cerebral Embolisation in Fulminant Mitral Valve Infective Endocarditis

    Directory of Open Access Journals (Sweden)

    Gemina Doolub

    2015-05-01

    Full Text Available A 37-year-old male with known intravenous drug use was admitted with an acute onset of worsening confusion and speech impairment. His vitals and biochemical profile demonstrated severe sepsis, with a brain CT showing several lesions suspicious for cerebral emboli. He then went on to have a bedside transthoracic echocardiogram that was positive for vegetation on the mitral valve, with associated severe mitral regurgitation. Unfortunately, before he was stable enough to be transferred for valve surgery, he suffered an episode of acute pulmonary oedema requiring intubation and ventilation on intensive care unit.

  17. Perioperative management of a patient with Dandy Walker malformation with tetralogy of Fallot undergoing total correction and fresh homologous pericardial pulmonary valve conduit implantation: Report of a rare case

    Directory of Open Access Journals (Sweden)

    Vishnu Datt

    2015-01-01

    Full Text Available Perioperative management of a patient with Dandy-Walker malformation (DWM with tetralogy of Fallot (TOF, patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP, conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo-peritoneal (VP shunt should be performed before cardiac surgery. We present the first case report of a 11-month-old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion.

  18. Fatal association of mechanical valve thrombosis with dabigatran: a report of two cases.

    Science.gov (United States)

    Atar, Shaul; Wishniak, Alice; Shturman, Alexander; Shtiwi, Sewaed; Brezins, Marc

    2013-07-01

    Several new oral anticoagulants have been approved for thromboembolism prevention in patients with nonvalvular atrial fibrillation. However, they are not yet approved for anticoagulation use in patients with prosthetic mechanical valves, and no randomized data have been published so far on their safety of use in these patients. We present two cases of patients with prosthetic mechanical mitral valves who were switched from warfarin and acenocoumarol to dabigatran and within 1 month experienced severe valve complications resulting in death. One patient experienced stroke and later cardiogenic shock and death, and the other experienced pulmonary edema, cardiogenic shock, and subsequent death.

  19. Comparative assessment of hepatic Glisson's capsule and bovine pericardium in heart valve bioprostheses.

    Science.gov (United States)

    Kagramanov, I I; Kokshenev, I V; Dobrova, N B; Kastava, V T; Serov, R A; Zaets, S B

    1998-05-01

    The optimal material for heart valve bioprostheses remains disputable. This investigation was initiated to compare the properties of hepatic Glisson's capsule, clinical experience of which in cardiovascular surgery is minimal, with those of bovine pericardium. Hepatic Glisson's capsule was harvested from bull calves and used to create composite pulmonary arterial monocusp grafts and bioprostheses. Comparison of the strength and elastic properties of Glisson's capsule and bovine pericardium, as well as the hydrodynamic characteristics of valves made from these materials, was performed. Late results of operations using these materials were estimated echocardiographically. Although Glisson's capsule tissue is thinner than the bovine pericardium, its elasticity modulus is greater. However, the hydrodynamic characteristics of heart valves made from either tissue are similar. Moreover, valves made from Glisson's capsule have a lower systolic pressure gradient on the prosthesis and a higher effective orifice area. Composite pulmonary arterial xenopericardial grafts with a monocusp of Glisson's capsule were used in 30 patients during tetralogy of Fallot repair. Glisson's capsule was also used for tricuspid valve reconstruction and as a bioprosthesis in six patients with Ebstein's anomaly. At 1-2 years after surgery, the Glisson's capsule tissue remained thin and flexible, with no calcification. Although the hydrodynamic properties of hepatic Glisson's capsule and the bovine pericardium are similar, the capsule tissue is thinner and has a greater elasticity modulos. Thus, Glisson's capsule may be used for bioprosthesis construction both independently and in combination with bovine pericardium.

  20. Effect of endobronchial valve therapy on pulmonary perfusion and ventilation distribution.

    Directory of Open Access Journals (Sweden)

    Carmen Pizarro

    Full Text Available Endoscopic lung volume reduction (ELVR is an emerging therapy for emphysematous COPD. However, any resulting changes in lung perfusion and ventilation remain undetermined. Here, we report ELVR-mediated adaptations in lung perfusion and ventilation, as investigated by means of pulmonary scintigraphy.In this observational study, we enrolled 26 patients (64.9 ± 9.4 yrs, 57.7% male with COPD heterogeneous emphysema undergoing ELVR with endobronchial valves (Zephyr, Pulmonx, Inc.. Mean baseline FEV1 and RV were 32.9% and 253.8% predicted, respectively. Lung scintigraphy was conducted prior to ELVR and eight weeks thereafter. Analyses of perfusion and ventilation shifts were performed and complemented by correlation analyses between paired zones.After ELVR, target zone perfusion showed a mean relative reduction of 43.32% (p<0.001, which was associated with a significant decrease in target zone ventilation (p<0.001. Perfusion of the contralateral untreated zone and of the contralateral total lung exhibited significant increases post-ELVR (p = 0.002 and p = 0.005, respectively; both correlated significantly with the corresponding target zone perfusion adaptations. Likewise, changes in target zone ventilation correlated significantly with ventilatory changes in the contralateral untreated zone and the total contralateral lung (Pearson's r: -0.42, p = 0.04 and Pearson's r: -0.42, p = 0.03, respectively. These effects were observed in case of clinical responsiveness to ELVR, as assessed by changes in the six-minute walk test distance.ELVR induces a relevant decrease in perfusion and ventilation of the treated zone with compensatory perfusional and ventilatory redistribution to the contralateral lung, primarily to the non-concordant, contralateral zone.

  1. A mycotic pulmonary artery aneurysm associated with candida endocarditis: Case report

    International Nuclear Information System (INIS)

    Moon, Jin Il; Lee, Ji Won; Jeong, Yeon Joo; Song, Seung Hwan

    2014-01-01

    We report a case of a mycotic pulmonary aneurysm associated with Candida endocarditis in a 53-year-old male with lymphoma. The initial diagnosis was a pulmonary artery aneurysm attributable to vasculitis, such as that associated with Behcet's disease, but a mycotic pulmonary artery aneurysm was later considered as a differential diagnosis. Identification of valve vegetation on the chest CT was helpful in this regard. We review the literature on the disease etiology, radiological findings, and management options.

  2. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. A mycotic pulmonary artery aneurysm associated with candida endocarditis: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jin Il; Lee, Ji Won; Jeong, Yeon Joo; Song, Seung Hwan [Pusan National University School of Medicine, Medical Research Institute, Pusan National University Hospital, Busan (Korea, Republic of)

    2014-03-15

    We report a case of a mycotic pulmonary aneurysm associated with Candida endocarditis in a 53-year-old male with lymphoma. The initial diagnosis was a pulmonary artery aneurysm attributable to vasculitis, such as that associated with Behcet's disease, but a mycotic pulmonary artery aneurysm was later considered as a differential diagnosis. Identification of valve vegetation on the chest CT was helpful in this regard. We review the literature on the disease etiology, radiological findings, and management options.

  4. Results of transcatheter pulmonary valvulation in native or patched right ventricular outflow tracts.

    Science.gov (United States)

    Malekzadeh-Milani, Sophie; Ladouceur, Magalie; Cohen, Sarah; Iserin, Laurence; Boudjemline, Younes

    2014-11-01

    Although widely accepted worldwide, indications for percutaneous valve replacement are limited to treatment of dysfunction of prosthetic conduits inserted in the right ventricular outflow tract (RVOT). There has been little evaluation of the use of the Melody(®) valve for patched non-circular pulmonary pathways. To evaluate the outcomes of Melody valve insertion in patients with a patched non-circular RVOT. We analysed procedural and outcomes data from 34 patients who underwent Melody valve implantation for a non-circular RVOT. RVOT preparation was done in all patients, using different techniques (conventional, Russian doll and/or PA jailing). Melody valve insertion was performed concomitantly in most patients. All procedures were successful. Sixteen patients had complex additional procedures, including the jailing technique (n=5), the Russian doll technique (n=6) and multiple stent implantations (Russian jailing; n=5). The remaining patients were treated using the conventional technique with systematic prestenting. Three early complications occurred: one haemoptysis; one residual RVOT obstruction needing recatheterization 48 hours after percutaneous pulmonary valve implantation; and one stent embolization during advancement of the Ensemble(®) delivery system. The mean follow-up period was 2.6 years postprocedure. There was no stent fracture, migration or embolization. Two patients developed a significant paraprosthetic leak and one received a second Melody valve. Careful patient selection, balloon sizing and RVOT preparation with prestenting are required to create a safe landing zone for the Melody valve. Short-term follow-up shows excellent results with no stent fracture or migration and appears promising. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. Fatal postoperative systemic pulmonary hypertension in benfluorex-induced valvular heart disease surgery: A case report.

    Science.gov (United States)

    Baufreton, Christophe; Bruneval, Patrick; Rousselet, Marie-Christine; Ennezat, Pierre-Vladimir; Fouquet, Olivier; Giraud, Raphael; Banfi, Carlo

    2017-01-01

    Drug-induced valvular heart disease (DI-VHD) remains an under-recognized entity. This report describes a heart valve replacement which was complicated by intractable systemic pulmonary arterial hypertension in a 61-year-old female with severe restrictive mitral and aortic disease. The diagnosis of valvular disease was preceded by a history of unexplained respiratory distress. The patient had been exposed to benfluorex for 6.5 years. The diagnostic procedure documented specific drug-induced valvular fibrosis. Surgical mitral and aortic valve replacement was performed. Heart valve replacement was postoperatively complicated by unanticipated disproportionate pulmonary hypertension. This issue was fatal despite intensive care including prolonged extracorporeal life support. Benfluorex is a fenfluramine derivative which has been marketed between 1976 and 2009. Although norfenfluramine is the common active and toxic metabolite of all fenfluramine derivatives, the valvular and pulmonary arterial toxicity of benfluorex was much less known than that of fenfluramine and dexfenfluramine. The vast majority of benfluorex-induced valvular heart disease remains misdiagnosed as hypothetical rheumatic fever due to similarities between both etiologies. Better recognition of DI-VHD is likely to improve patient outcome.

  6. "Pulmonary valve replacement diminishes the presence of restrictive physiology and reduces atrial volumes": a prospective study in Tetralogy of Fallot patients.

    Science.gov (United States)

    Pijuan-Domenech, Antonia; Pineda, Victor; Castro, Miguel Angel; Sureda-Barbosa, Carlos; Ribera, Aida; Cruz, Luz M; Ferreira-Gonzalez, Ignacio; Dos-Subirà, Laura; Subirana-Domènech, Teresa; Garcia-Dorado, David; Casaldàliga-Ferrer, Jaume

    2014-11-15

    Pulmonary valve replacement (PVR) reduces right ventricular (RV) volumes in the setting of long-term pulmonary regurgitation after Tetralogy of Fallot (ToF) repair; however, little is known of its effect on RV diastolic function. Right atrial volumes may reflect the burden of RV diastolic dysfunction. The objective of this paper is to evaluate the clinical, echocardiographic, biochemical and cardiac magnetic resonance (CMR) variables, focusing particularly on right atrial response and right ventricular diastolic function prior to and after elective PVR in adult patients with ToF. This prospective study was conducted from January 2009 to April 2013 in consecutive patients > 18 years of age who had undergone ToF repair in childhood and were accepted for elective PVR. Twenty patients (mean age: 35 years; 70% men) agreed to enter the study. PVR was performed with a bioporcine prosthesis. Concomitant RV reduction was performed in all cases when technically possible. Pulmonary end-diastolic forward flow (EDFF) decreased significantly from 5.4 ml/m(2) to 0.3 ml/m(2) (p volumes by 25% (p = 0.0024): mean indexed diastolic/systolic atrial volumes prior to surgery were 43 ml/m(2) (SD+/-4.6)/63 ml/m(2) (SD+/-5.5), and dropped to 33 ml/m(2) (SD+/-3)/46 ml/m(2) (SD+/-2.55) post-surgery. All patients presented right ventricular diastolic and systolic volume reductions, with a mean volume reduction of 35% (p volumes in keeping with the known reduction in RV volumes, after PVR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. [Foreign body in the tricuspid valve with valvular insufficiency and right-left shunt].

    Science.gov (United States)

    Delebarre, P; Augustin-Normand, C; Capronier, C; Cramer, J; Godeau, P; Letac, B; Forman, J; Maurice, P; Ourbak, P

    1987-05-01

    We present the case of a 50-year old man who progressively developed tricuspid valve insufficiency with opening of a patent foramen ovale responsible for right-to-left shunt with polycythaemia. The tricuspid valve insufficiency was due to a foreign body, probably of surgical origin as suggested by its radiological image and by the patient's previous history. It would have been introduced, far away from the tricuspid valve (compound fracture of the wrist), several years previously. At surgery, we found the foreign body embedded in the valve system. As a possible mechanism for the mutilation, an undiagnosed endocarditis was suspected but could not be confirmed. Three cases tricuspid endocarditis (with foreign bodies in the right ventricle) and 3 cases of asymptomatic tricuspid valve foreign bodies have been published. Fifty-five cases of foreign bodies introduced peripherally and migrated into the heart, the pericardium and the pulmonary artery are reviewed.

  8. Nitric Oxide-Sensitive Pulmonary Hypertension in Congenital Rubella Syndrome

    Directory of Open Access Journals (Sweden)

    Francesco Raimondi

    2015-01-01

    Full Text Available Persistent pulmonary hypertension is a very rare presentation of congenital virus infection. We discuss the case of complete congenital rubella syndrome presenting at echocardiography with pulmonary hypertension that worsened after ductus ligation. Cardiac catheterization showed a normal pulmonary valve and vascular tree but a PAP=40 mmHg. The infant promptly responded to inhaled nitric oxide while on mechanical ventilation and was later shifted to oral sildenafil. It is not clear whether our observation may be due to direct viral damage to the endothelium or to the rubella virus increasing the vascular tone via a metabolic derangement.

  9. Quantification of pulmonary regurgitation and prediction of pulmonary valve replacement by echocardiography in patients with congenital heart defects in comparison to cardiac magnetic resonance imaging.

    Science.gov (United States)

    Dellas, Claudia; Kammerer, Laura; Gravenhorst, Verena; Lotz, Joachim; Paul, Thomas; Steinmetz, Michael

    2018-04-01

    Pulmonary regurgitation (PR) is common in patients with congenital heart defects (CHD) and contributes to morbidity and mortality in the long-term. We investigated in this retrospective analysis whether readily accessible echocardiographic parameters are useful for quantification of PR and for predicting pulmonary valve replacement (PVR) in comparison to the gold-standard phase contrast (PC) flow measurements from cardiovascular magnetic resonance (CMR). Continuous wave (CW) Doppler and colour flow images in echocardiograms from 53 patients with CHD were analysed. Slope and jet-to-RVOT ratio correlated significantly with CMR-assessed regurgitation fraction (RF), whereas pressure half time (PHT) showed an inverse correlation. Patients with mild PR in CMR had significantly higher PHT, lower slope and jet-to-RVOT ratio than patients with moderate or severe regurgitation. The AUC regarding PR severity was 0.778 for PHT (95% CI, 0.649-0.907; P = 0.007 for CMR-RF ≤ 35%), 0.744 for slope (95% CI, 0.603-0.885; P = 0.017 for CMR-RF > 35%) and 0.652 for jet-to-RVOT ratio (95% CI, 0.473-0.860; P = 0.168 for CMR-RF > 35%). The optimal cut-off values calculated from ROC analysis were 95 ms for PHT and 4.9 m/s 2 for slope. In logistic regression analysis, slope emerged as the most valuable parameter for predicting the indication for PVR (OR 12.9, 95% CI, 1.8-90.9, P = 0.010). In conclusion, echocardiographic assessment of PR was feasible. Both parameters, PHT and in particular slope, were predictors for PVR. Thus, echocardiography appears appropriate in the management of patients with PR.

  10. A neonate with mitral stenosis due to accessory mitral valve, ventricular septal defect, and patent ductus arteriosus: changes in echocardiographical findings during the neonatal period.

    Science.gov (United States)

    Ito, Tadahiko; Okubo, Tadashi

    2002-12-01

    A female neonate with mitral stenosis due to accessory mitral valve with ventricular septal defect and patent ductus arteriosus is described. She was referred to our hospital because of neonatal asphyxia. Asphyxia was improved by ventilator support, but rapid deterioration of respiration with pulmonary congestion and hemorrhage appeared 8 days after birth. Echocardiography revealed an accessory mitral valve attached to the anterior mitral leaflet with a perimembranous ventricular septal defect and patent ductus arteriosus. Although there were no echocardiographical findings indicating mitral stenosis on admission, the mitral stenosis blood flow patterns were detected by color and pulsed Doppler examination performed on the eighth day after admission. Transaortic resection of accessory mitral valve tissue was performed with patch closure of the ventricular septal defect and ligation of the ductus arteriosus 35 days after birth. After operation, pulmonary congestion and hemorrhage were improved. Postoperative echocardiography showed complete resection of the accessory mitral valve and no mitral insufficiency. We concluded that the combination of the accessory mitral valve and left-to-right shunt due to ventricular septal defect or patent ducturs arteriosus might have led to a critical hemodynamic condition due to relative mitral stenosis in the neonatal period with the decrease in pulmonary vascular resistance.

  11. Mitral valve surgery using right anterolateral thoracotomy: is the aortic cannulation a safety procedure?

    Science.gov (United States)

    Guedes, Marco Antonio Vieira; Pomerantzeff, Pablo Maria Alberto; Brandão, Carlos Manuel de Almeida; Vieira, Marcelo Luiz Campos; Grinberg, Max; Stolf, Noedir Antonio Groppo

    2010-01-01

    The right anterolateral thoracotomy is an alternative technique for surgical approach of mitral valve. In these cases, femoral-femoral bypass still has been used, rising occurrence of complications related to femoral cannulation. Describe the technique and results of mitral valve treatment by right anterolateral thoracotomy using aortic cannulation for cardiac pulmonary bypass (CPB). From 1983 e 2008, 100 consecutive female patients, with average age 35 ±13 years, 96 (96%) underwent mitral valve surgical treatment in the Heart Institute of São Paulo. A right anterolateral thoracotomy approach associated with aortic cannulation was used for CPB. Eighty (80%) patients had rheumatic disease and 84 (84%) patients presented functional class III or IV. Were performed 45 (45%) comissurotomies, 38 (38%) valve repairs, 7(7%) mitral valve replacements, seven (7%) recomissurotomies and three (3%) prosthesis replacement. Sparing surgery was performed in 90 (90%) patients. The average CPB and clamp time were 57 ± 27 min e 39 ± 19 min, respectively. There were no in-hospital death, reoperation due to bleeding and convertion to sternotomy. Introperative complications were related to heart harvest (5%), especially in reoperations (3%). The most important complications in postoperative period were related to pulmonary system (11%), followed by atrial fibrilation (10%) but without major systemic repercussions. The mean inhospital length of stay was 8 ± 3 days. Follow-up was 6.038 patients/month. Actuarial survival was 98.0 ± 1.9% and freedom from reoperation was 81.4 ± 7.8% in 180 months. The right anterolateral thoracotomy associated with aortic cannulation in mitral valve surgery is a simple technique, reproducible and safety.

  12. Transcatheter versus surgical valve replacement for a failed pulmonary homograft in the Ross population.

    Science.gov (United States)

    Alassas, Khadija; Mohty, Dania; Clavel, Marie Annick; Husain, Aysha; Hijji, Talal; Aljoufan, Mansour; Alhalees, Zohair; Fadel, Bahaa M

    2018-04-01

    Patients who undergo the Ross procedure are at increased risk of pulmonary valve (PV) homograft dysfunction. For those who require reintervention on the homograft, transcatheter PV replacement (tPVR) provides a less invasive therapeutic option than surgical PVR (sPVR). We examined the outcomes following tPVR versus sPVR in a cohort of patients who underwent the Ross procedure. We performed a retrospective analysis of Ross patients age ≥14 years who underwent tPVR (n = 47) or sPVR (n = 41) at our institution. The patients' clinical and echocardiographic data were reviewed. Baseline parameters, including demographic data and left ventricular and right ventricular (RV) systolic function, were similar in the 2 groups. The mean follow-up was 56 ± 24 months for the tPVR group and 89 ± 46 months for the sPVR group (P Ross patients who require reintervention on the PV homograft, both tPVR and sPVR provide low procedural mortality and comparable midterm outcome with no significant difference in mortality or PV reintervention. However, IE is more common following tPVR. A larger randomized study is needed to determine the role of each procedure in patient management. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Interventional catheter methods for complex tetralogy of fallot and 'Critical' PS/pulmonary atresia with intact interventional septum

    International Nuclear Information System (INIS)

    Issenberg, H.J.

    2005-01-01

    flow for 'rehabilitation' and preserving RV function. Alternatively, some surgeons perform 'unifocalization', which for the interventionist achieves the same direct antegrade access into the pulmonary arterial tree. Our eventual goals are to recruit the maximal functional pulmonary vascular bed with the lowest resistance, balancing the ventilation-perfusion ratio, while minimizing the RV pressure and volume overload. A residual ASD and/or VSD, either deliberately left as a palliative 'fenestration' or an unwanted patch leak, can later be occluded with a device in the cath lab. The natural history of RV to PA conduits has been disappointing. Frequently, these develop stenosis at the homograft valve or from an intimal peel. In these situation, short-term extension of conduit life can be accomplished with ballooning and/or stenting. If the conduit has an acute bend, usually from sternal compression, non-surgical relief is difficult to accomplish. For those chronically volume loaded and dysfunctional RVs, xenograft valves mounted into stents have been percutaneously delivered during catheterization, providing a competent pulmonary valve, leading to diminished symptoms. Early results look promising, and in select cases may prolong conduit longevity, obviating the need for surgical reoperation. A more aggressive interventional approach has evolved for the treatment of pulmonary atresia with an intact interventricular septum. If the diagnostic evaluation reveals an adequate RV morphology and size for a two-ventricle approach, along with membranous pulmonary valve atresia and a non-RV dependent coronary circulation, an attempt at valve perforations is warranted. Frequently, the valve can be crossed gently with a guide wire, followed by progressive balloon dilations. If the valve is resistant to mechanical perforation, radio frequency or excimer laser is utilized to burn a hole through the membrane, followed by progressive dilations, with a resultant drop in RV pressure. This

  14. Pulmonary Hypertension with Left Heart Disease: Prevalence, Temporal Shifts in Etiologies and Outcome.

    Science.gov (United States)

    Weitsman, Tatyana; Weisz, Giora; Farkash, Rivka; Klutstein, Marc; Butnaru, Adi; Rosenmann, David; Hasin, Tal

    2017-11-01

    Pulmonary hypertension has many causes. While it is conventionally thought that the most prevalent is left heart disease, little information about its proportion, causes, and implications on outcome is available. Between 1993 and 2015, 12,115 of 66,949 (18%) first adult transthoracic echocardiograms were found to have tricuspid incompetence gradient ≥40 mm Hg, a pulmonary hypertension surrogate. Left heart disease was identified in 8306 (69%) and included valve malfunction in 4115 (49%), left ventricular systolic dysfunction in 2557 (31%), and diastolic dysfunction in 1776 (21%). Patients with left heart disease, as compared with those without left heart disease, were of similar age, fewer were females (50% vs 63% P pulmonary hypertension with left heart disease. Independent predictors of mortality were age (hazard ratio [HR] 1.05; 95% CI, 1.04-1.05; P pulmonary hypertension but without left heart disease (HR 1.30; 95% CI, 1.20-1.42 and HR 1.44; 95% CI, 1.33-1.55, respectively; P Pulmonary hypertension was found to be associated with left heart disease in 69% of patients. Among these patients, valve malfunction and diastolic dysfunction emerged as prominent causes. Left ventricular dysfunction carries additional risk to patients with pulmonary hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  16. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  17. X-ray appearance of the heart in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Matveeva, L.S.; Kitaeva, I.T.; Efimova, L.G.

    1980-01-01

    Roentgenological picture of heart in 36 patients with primary pulmonary hypertension is studied. The diagnosis has been reaffirmed using catheterization of cavities of the heart and pulmonary artery and in a number of cases in autopsy. Variability of the form and the size of the heart depending on different degrees of hypertrophy and dilatation of the right ventricle with possible relative insufficiency of the tricuspid valve and on different degree of ecstasia of the pulmonary arterial trunk and functional state of myocardium. All this to a certain degree is dependent on the patient age, duration and the character of the disease

  18. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  19. Early versus late pulmonary valve replacement in patients with transannular patch-repaired tetralogy of Fallot.

    Science.gov (United States)

    Dobbels, Bieke; Herregods, Marie-Christine; Troost, Els; Van De Bruaene, Alexander; Rega, Filip; Budts, Werner; De Meester, Pieter

    2017-09-01

    Although the effects of pulmonary regurgitation after tetralogy of Fallot repair are detrimental, timing of pulmonary valve replacement (PVR) is unclear. Our goal was to evaluate the midterm efficacy and safety of early PVR. Patients with tetralogy of Fallot who underwent repair from 1962 to 2015 were included from the local database. Statistical analyses compared patients who underwent early PVR (age ≤16 years), late PVR and no PVR. The timing of the intervention was compared for efficacy-all-cause mortality and the combined end-point of all-cause mortality, ventricular tachycardia and defibrillator implantation-and for safety-the combined end-point of 1-year postoperative mortality after PVR, endocarditis and reintervention. Echocardiographic and electrocardiographic data at the last follow-up examination were compared across the 3 groups. Two hundred seventy-three patients (age 21 ± 5 years; 52% female) were included. The mean follow-up was 24 (95% confidence interval 22.7-26.2) years; the observed median was 21 years (interquartile range 11-31). No significant difference in survival was found between the early PVR (n = 106; 39%), the late PVR (n = 47; 17%) and the no PVR groups (n = 120; 44%) (P = 0.990). No significant difference in the combined efficacy end-point was noted between patients who underwent early PVR compared with patients who underwent late PVR (P = 0.247). Worse event-free survival for the 3-point safety end-point was observed after early PVR (P < 0.001). Right ventricular morphology (P < 0.001) and function (P < 0.001) were better preserved in the patient group that underwent PVR before the age of 16 years. As expected, PVR-related morbidity was higher in patients who underwent early PVR but the midterm outcome was similar. Nevertheless, better preservation of right ventricular morphology and function in the early PVR group might result in better long-term survival. © The Author 2017. Published by Oxford

  20. Biphasic 201thallium scintgraphy after dipyridamole in mitral valve diseases

    International Nuclear Information System (INIS)

    Schmoliner, R.; Dudczak, R.; Kronik, G.; Moesslacher, H.; Kletter, K.; Frischauf, H.

    1980-01-01

    The results of biphasic 201 thallium scintigraphy after dipyridamole i.v. could neither prove nor exclude the presence of small focal lesions in the myocardium of 17 patients with mitral valve diseases. The frequent finding of a decrease in activity in the anterolateral myocardium is probably due to a relative increase in activity in the region of the inferior wall with superimposed areas of the papillary muscle and right ventricular myocardium. If the right ventricle is visualized in stress- or redistribution images, an increase in mean pulmonary artery pressure can be accepted. According to Cohen's criteria, a grade 2 or 3 virtually proves the existence of pulmonary hypertension, a grade 1 makes this finding rather probable. The possibility of pulmonary hypertension can not be excluded if the right ventricular myocardium is not visualized. (orig.) [de

  1. Spontaneous Pneumothorax as a Complication of Septic Pulmonary Embolism in an Intravenous Drug User: A Case Report

    Directory of Open Access Journals (Sweden)

    Chau-Chyun Sheu

    2006-02-01

    Full Text Available Infective endocarditis has been the major cause of morbidity and mortality among intravenous drug users (IDUs with infections, mostly involving the tricuspid valve and presenting multiple septic pulmonary embolisms. Numerous pulmonary complications of septic pulmonary embolism have been described, but only a few have reported spontaneous pneumothorax. Our patient, a 23-year-old heroin addict, was hospitalized for tricuspid endocarditis and septic pulmonary embolism. Acute onset of respiratory distress occurred on his seventh hospital day and rapidly resulted in hypoxemia. Immediate bedside chest radiograph demonstrated left pneumothorax. It was thought to be a spontaneous pneumothorax, because he had not undergone any invasive procedure before the occurrence of pneumothorax. His clinical condition improved after the insertion of an intercostal chest tube. He later underwent surgery to replace the tricuspid valve as a result of the large size of the vegetation and poor control of infection. He ultimately survived. Pneumothorax is a possible lethal complication of septic pulmonary embolism in IDUs with right-sided endocarditis and should be considered in such patients when respiratory distress occurs acutely during their hospitalization.

  2. [Traumatic tricuspid valve insufficiency with right-to-left shunt: bridging using extracorporeal venovenous membrane oxygenation].

    Science.gov (United States)

    Weber, S U; Hammerstingl, C; Mellert, F; Baumgarten, G; Putensen, C; Knuefermann, P

    2012-01-01

    The case of a young male motor vehicle driver is reported who suffered multiple trauma in a car accident with pulmonary and cardiac contusions. In the course of severe pneumonia and traumatic tricuspid valve insufficiency a right-to-left shunt with refractory hypoxemia developed across a pre-existing atrial septal defect (ASD). The patient could be successfully treated by the combination of extracorporeal membrane oxygenation for bridging, interventional ASD occlusion and in the long-term by operative reconstruction of the tricuspid valve.

  3. Videodensitometry in rats with pulmonary damage due to microembolism

    Energy Technology Data Exchange (ETDEWEB)

    Wegenius, G.; Wegener, T.; Ruhn, G.; Saldeen, T.; Erikson, U.

    Serial pulmonary angiography with videodensitometry was performed in 18 rats with pulmonary damage caused by administration of a fibrinolysis inhibitor, tranexamic acid (200 mg/kg body weight injected intraperitoneally) and bovine thrombin (500 NIH/kg body weight injected into the right femoral vein). The mean transit time (MTT) was calculated from videodensitometry, the observed area of interest consisting of approximately one-third of the right lung, including both central and peripheral parts. The impact of the pulmonary damage was analysed by morphologic methods and correlated to MTT. Although a pressure rise presumably occurred in the pulmonary circulation, no change in MTT was found after induction of pulmonary damage, indicating opening of actual and potential anastomoses between pulmonary arterioles and venules to serve as by-pass portions and as a safety-valve mechanism for the capillary bed and the right heart, respectively. Another explanation to unchanged MTT may be opening of resting capillary beds. Two rats with very severe pulmonary damage showed prolonged MTT. These rats may have suffered from cardiac failure.

  4. Videodensitometry in rats with pulmonary damage due to microembolism

    International Nuclear Information System (INIS)

    Wegenius, G.; Wegener, T.; Ruhn, G.; Saldeen, T.; Erikson, U.

    1985-01-01

    Serial pulmonary angiography with videodensitometry was performed in 18 rats with pulmonary damage caused by administration of a fibrinolysis inhibitor, tranexamic acid (200 mg/kg body weight injected intraperitoneally) and bovine thrombin (500 NIH/kg body weight injected into the right femoral vein). The mean transit time (MTT) was calculated from videodensitometry, the observed area of interest consisting of approximately one-third of the right lung, including both central and peripheral parts. The impact of the pulmonary damage was analysed by morphologic methods and correlated to MTT. Although a pressure rise presumably occurred in the pulmonary circulation, no change in MTT was found after induction of pulmonary damage, indicating opening of actual and potential anastomoses between pulmonary arterioles and venules to serve as by-pass portions and as a safety-valve mechanism for the capillary bed and the right heart, respectively. Another explanation to unchanged MTT may be opening of resting capillary beds. Two rats with very severe pulmonary damage showed prolonged MTT. These rats may have suffered from cardiac failure. (orig.)

  5. Pulmonary valve replacement after operative repair of tetralogy of Fallot: meta-analysis and meta-regression of 3,118 patients from 48 studies.

    Science.gov (United States)

    Ferraz Cavalcanti, Paulo Ernando; Sá, Michel Pompeu Barros Oliveira; Santos, Cecília Andrade; Esmeraldo, Isaac Melo; de Escobar, Rodrigo Renda; de Menezes, Alexandre Motta; de Azevedo, Orlando Morais; de Vasconcelos Silva, Frederico Pires; Lins, Ricardo Felipe de Albuquerque; Lima, Ricardo de Carvalho

    2013-12-10

    Because the real benefit of pulmonary valve replacement (PVR) in patients with repaired tetralogy of Fallot who develop pulmonary insufficiency remains unclear, it is necessary to analyze the evidence published around the world. We performed a systematic review of studies that reported data about the effect of PVR in patients with repaired tetralogy of Fallot that developed pulmonary insufficiency, until December 2012. The variables chosen to represent the benefit were both right ventricular (RV) and left ventricular measures, QRS duration, and functional class. The principal summary measures were difference in means with 95% confidence interval and p values (considered statistically significant when p regression were completed with the software Comprehensive Meta-Analysis (version 2, Biostat, Inc., Englewood, New Jersey). Forty-eight studies involving 3,118 patients met the eligibility criteria. The pooled 30-day mortality was 0.87% (47 studies; 27 of 3,100 patients); the pooled 5-year mortality was 2.2% (24 studies; 49 of 2,231 patients); the pooled 5-year re-PVR was 4.9% (15 studies; 88 of 1,798 patients). The results of this meta-analysis demonstrate that after PVR: 1) the RV experiences improvement of its volumes and function; 2) the left ventricle experiences improvement of its function; 3) QRS duration decreases; 4) symptoms improve; 5) pre-operative RV geometry modulates the effect of PVR; and 6) there is important heterogeneity of the effects among the studies, and few publication biases. In conclusion, PVR seems to be a positive approach in the analyzed scenario. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Fine Structure of Glycosaminoglycans from Fresh and Decellularized Porcine Cardiac Valves and Pericardium

    Directory of Open Access Journals (Sweden)

    Antonio Cigliano

    2012-01-01

    Full Text Available Cardiac valves are dynamic structures, exhibiting a highly specialized architecture consisting of cells and extracellular matrix with a relevant proteoglycan and glycosaminoglycan content, collagen and elastic fibers. Biological valve substitutes are obtained from xenogenic cardiac and pericardial tissues. To overcome the limits of such non viable substitutes, tissue engineering approaches emerged to create cell repopulated decellularized scaffolds. This study was performed to determine the glycosaminoglycans content, distribution, and disaccharides composition in porcine aortic and pulmonary valves and in pericardium before and after a detergent-based decellularization procedure. The fine structural characteristics of galactosaminoglycans chondroitin sulfate and dermatan sulfate were examined by FACE. Furthermore, the mechanical properties of decellularized pericardium and its propensity to be repopulated by in vitro seeded fibroblasts were investigated. Results show that galactosaminoglycans and hyaluronan are differently distributed between pericardium and valves and within heart valves themselves before and after decellularization. The distribution of glycosaminoglycans is also dependent from the vascular district and topographic localization. The decellularization protocol adopted resulted in a relevant but not selective depletion of galactosaminoglycans. As a whole, data suggest that both decellularized porcine heart valves and bovine pericardium represent promising materials bearing the potential for future development of tissue engineered heart valve scaffolds.

  7. Retrospective analysis of co-occurrence of congenital aortic stenosis and pulmonary artery stenosis in dogs.

    Science.gov (United States)

    Kander, M; Pasławska, U; Staszczyk, M; Cepiel, A; Pasławski, R; Mazur, G; Noszczyk-Nowak, A

    2015-01-01

    The study has focused on the retrospective analysis of cases of coexisting congenital aortic stenosis (AS) and pulmonary artery stenosis (PS) in dogs. The research included 5463 dogs which were referred for cardiological examination (including clinical examination, ECG and echocardiography) between 2004 and 2014. Aortic stenosis and PS stenosis were detected in 31 dogs. This complex defect was the most commonly diagnosed in Boxers - 7 dogs, other breeds were represented by: 4 cross-breed dogs, 2 Bichon Maltais, 3 Miniature Pinschers, 2 Bernese Mountain Dogs, 2 French Bulldogs, and individuals of following breeds: Bichon Frise, Bull Terrier, Czech Wolfdog, German Shepherd, Hairless Chinese Crested Dog, Miniature Schnauzer, Pug, Rottweiler, Samoyed, West Highland White Terrier and Yorkshire Terrier. In all the dogs, the murmurs could be heard, graded from 2 to 5 (on a scale of 1-6). Besides, in 9 cases other congenital defects were diagnosed: patent ductus arteriosus, mitral valve dysplasia, pulmonary or aortic valve regurgitation, tricuspid valve dysplasia, ventricular or atrial septal defect. The majority of the dogs suffered from pulmonary valvular stenosis (1 dog had supravalvular pulmonary artery stenosis) and subvalvular aortic stenosis (2 dogs had valvular aortic stenosis). Conclusions and clinical relevance - co-occurrence of AS and PS is the most common complex congenital heart defect. Boxer breed was predisposed to this complex defect. It was found that coexisting AS and PS is more common in male dogs and the degree of PS and AS was mostly similar.

  8. Thoracic Malignancies and Pulmonary Nodules in Patients under Evaluation for Transcatheter Aortic Valve Implantation (TAVI): Incidence, Follow Up and Possible Impact on Treatment Decision

    Science.gov (United States)

    Kaleschke, Gerrit; Schülke, Christoph; Görlich, Dennis; Schliemann, Christoph; Kessler, Torsten; Schulze, Arik Bernard; Buerke, Boris; Kuemmel, Andreas; Thrull, Michael; Wiewrodt, Rainer; Baumgartner, Helmut; Berdel, Wolfgang E.; Mohr, Michael

    2016-01-01

    Background Transcatheter aortic valve implantation (TAVI) has become the treatment of choice in patients with severe aortic valve stenosis who are not eligible for operative replacement and an alternative for those with high surgical risk. Due to high age and smoking history in a high proportion of TAVI patients, suspicious findings are frequently observed in pre-procedural chest computer tomography (CCT). Methods CCT scans of 484 consecutive patients undergoing TAVI were evaluated for incidentally discovered solitary pulmonary nodules (SPN). Results In the entire study population, SPN ≥ 5 mm were found in 87 patients (18%). These patients were compared to 150 patients who were incidentally collected from the 397 patients without SPN or with SPN 8 mm (p = 0.328) were significant predictors of overall survival. Conclusions Despite the high prevalence of SPNs in this single center TAVI cohort lung cancer incidence at midterm follow-up seems to be low. Thus, aggressive diagnostic approaches for incidentally discovered SPN during TAVI evaluation should not delay the treatment of aortic stenosis. Unless advanced thoracic malignancy is obvious, the well documented reduction of morbidity and mortality by TAVI outweighs potentially harmful delays regarding further diagnostics. Standard guideline-approved procedure for SPN can be safely performed after TAVI. PMID:27171441

  9. Aortic valve replacement with the Biocor PSB stentless xenograft.

    Science.gov (United States)

    Bertolini, P; Luciani, G B; Vecchi, B; Pugliese, P; Mazzucco, A

    1998-08-01

    The midterm clinical results after aortic valve replacement with the Biocor PSB stentless xenograft on all patients operated between October 1992 and October 1996 were reviewed. One hundred six patients, aged 70+/-6 years, had aortic valve replacement for aortic stenosis (67%), regurgitation (11%), or both (22%). Associated procedures were done in 49 patients (46%), including coronary artery bypass in 30 patients, mitral valve repair/replacement in 16, and ascending aorta replacement in 5 patients. Aortic cross-clamp and cardiopulmonary bypass times were 96+/-24 and 129+/-31 minutes, respectively. There were 3 (3%) early deaths due to low output (2 patients) and cerebrovascular accident (1 patient). Follow-up of survivors ranged from 6 to 66 months (mean, 39+/-14 months). Survival was 94%+/-2% and 90%+/-3% at 1 and 5 years. There were 5 late deaths due to cardiac cause (2), cancer (2), and pulmonary embolism (1 patient). No patient had structural valve deterioration, whereas 100% and 95%+/-3% were free from valve-related events at 1 and 5 years. There were two reoperations due to narrowing of the left coronary ostium and endocarditis, with an actuarial freedom from reoperation of 99%+/-1% and 98+/-1% at 1 and 5 years, respectively. Functional results demonstrated a mean peak transprosthetic gradient of 16+/-12 mm Hg, with only 1 patient (1%) with a 55 mm Hg gradient. No cases of valve regurgitation greater than mild were recorded at follow-up. Assessment of New York Heart Association functional class demonstrated a significant improvement (2.9+/-0.6 versus 1.4+/-0.7; p=0.01). All patients were free from anticoagulation. Aortic valve replacement using the Biocor PSB stentless xenograft offers excellent midterm survival, negligible valve deterioration, and a very low rate of valve-related events, which are comparable to estimates reported with other models of stentless xenografts and currently available stented xenografts. Hemodynamic performance is favorable and

  10. Mechanical valve assembly for xenon 133 gas delivery systems

    Energy Technology Data Exchange (ETDEWEB)

    Round, W.H. (Royal Brisbane Hospital, Herston (Australia))

    Some gas delivery systems used in pulmonary ventilation scanning are unable to satisfactorily supply /sup 133/Xe gas to bed-ridden patients. A mechanical gas valve assembly to control the flow of gas in such systems was constructed. A commercially produced /sup 133/Xe gas delivery system when fitted with the new assembly was able to ventilate almost all patients whereas previously this could be achieved with approximately only 50% of patients.

  11. CD133 antibody conjugation to decellularized human heart valves intended for circulating cell capture.

    Science.gov (United States)

    Vossler, John D; Min Ju, Young; Williams, J Koudy; Goldstein, Steven; Hamlin, James; Lee, Sang Jin; Yoo, James J; Atala, Anthony

    2015-09-03

    The long term efficacy of tissue based heart valve grafts may be limited by progressive degeneration characterized by immune mediated inflammation and calcification. To avoid this degeneration, decellularized heart valves with functionalized surfaces capable of rapid in vivo endothelialization have been developed. The aim of this study is to examine the capacity of CD133 antibody-conjugated valve tissue to capture circulating endothelial progenitor cells (EPCs). Decellularized human pulmonary valve tissue was conjugated with CD133 antibody at varying concentrations and exposed to CD133 expressing NTERA-2 cl.D1 (NT2) cells in a microflow chamber. The amount of CD133 antibody conjugated on the valve tissue surface and the number of NT2 cells captured in the presence of shear stress was measured. Both the amount of CD133 antibody conjugated to the valve leaflet surface and the number of adherent NT2 cells increased as the concentration of CD133 antibody present in the surface immobilization procedure increased. The data presented in this study support the hypothesis that the rate of CD133(+) cell adhesion in the presence of shear stress to decellularized heart valve tissue functionalized by CD133 antibody conjugation increases as the quantity of CD133 antibody conjugated to the tissue surface increases.

  12. Pericardial tissue valves and Gore-Tex conduits as an alternative for right ventricular outflow tract replacement in children.

    Science.gov (United States)

    Allen, Bradley S; El-Zein, Chawki; Cuneo, Betina; Cava, Joseph P; Barth, Mary Jane; Ilbawi, Michel N

    2002-09-01

    There is still no perfect conduit for reconstruction of the right ventricular outflow tract (RVOT) in children. Homografts are not always available in the appropriate size, and degenerate in a few years. This study evaluates the pericardial valve with Gore-Tex conduit as an alternative for RVOT construction. From January 1, 1993, to September 30, 1999, a pericardial tissue valve was inserted in all patients undergoing RVOT reconstruction or pulmonary valve replacement (PVR) who were large enough to accommodate a tissue valve. In patients without a native main pulmonary artery, a new technique was used to construct an RV-PA conduit out of a flat sheet of Gore-Tex, as Dacron frequently leads to stenosis. Data were collected by retrospective review, follow-up echocardiograms, and assessment by a single cardiologist. There were 48 patients, 22 undergoing a PVR alone and 26 a RV-PA valved Gore-Tex conduit. Diagnosis included tetralogy of Fallot (n = 25); truncus arteriosis (n = 9); ventricular septal defect with PA (n = 5); DORV (n = 4); D-TGA with PS (n = 2); and 1 each IAA with sub AS, VSD with PI, and PS s/p Ross procedure. Patient age ranged from 3 to 33 years and 98% were reoperations. The valve sizes ranged from 19 to 33 mm and the median hospital length of stay was 4 days. There were 2 (4.2%) perioperative and 1 (2.1%) late deaths, none related to the valve or Gore-Tex conduit. At a follow-up of 15 to 86 months (mean 43 +/- 16 months), all remaining 45 patients are New York Heart Association class I, all valves are functional, and no patient has required valve or conduit replacement or revision; more importantly, echocardiogram revealed no significant valve or conduit stenosis (mean gradient 16 +/- 8 mm Hg) and no evidence of regurgitation or structural degeneration. A pericardial tissue valve and Gore-Tex conduit provides a reliable alternative for RVOT reconstruction in pediatric patients. It is readily available, molds in the limited retrosternal space, and

  13. Estenose pulmonar valvar discreta: a possível cura espontânea na evolução natural do defeito Mild pulmonary valve stenosis: the possible spontaneous cure in the natural history of the defect

    Directory of Open Access Journals (Sweden)

    Edmar Atik

    2006-05-01

    Full Text Available OBJETIVO: Determinar a evolução natural, a longo prazo, de pacientes com estenose pulmonar valvar discreta. MÉTODOS: No período evolutivo de 24 anos (1980 a 2004, foram avaliados 83 pacientes com estenose pulmonar valvar, sendo 29 destes em grau discreto. Destes 29, foram acompanhados, a longo prazo, 13 pacientes. A idade média na primeira e na última consulta correspondeu a 34 meses (1 mês a 15 anos e 10,5 anos (3 a 24 anos, respectivamente. Avaliaram-se, como elementos evolutivos, os referentes à clínica, os aspectos eletrocardiográficos e os ecocardiográficos. RESULTADOS: Todos os pacientes mantiveram-se assintomáticos. Quanto ao gradiente de pressão valvar pulmonar, em 5 (38,4% houve diminuição, manutenção em 3 (23%, eliminação em 4 (30,7% e acentuação para grau moderado em 1 (7,6%. O gradiente médio inicial e final foi de 24,2 mmHg (15 a 30 e de 13,6 mmHg (0-54. Os gradientes iniciais dos 4 pacientes que obtiveram a cura espontânea eram de 30, 19, 30 e 20 mmHg. O sopro sistólico e a sobrecarga ventricular direita guardaram relação com o grau do gradiente de pressão, subdividido a cada 10 mmHg. CONCLUSÃO: A cura espontânea da estenose pulmonar valvar discreta é possível, de igual modo que ocorre em outras anomalias acianogênicas.OBJECTIVE: To determine the long-term natural history of patients with mild pulmonary valve stenosis METHODS: Throughout a 24-year evolutive period (1980 a 2004, 83 patients with pulmonary valve stenosis were evaluated, with 29 of them presenting a mild form of the defect. Of these 29, 13 patients had a long-term follow up. The mean age at the first and last follow-up visits was 34 months (1 month to 15 years and 10.5 years (3 to 24 years, respectively. In addition to evolutive elements, those regarding clinical, electrocardiographic and echocardiographic aspects were also assessed. RESULTS: All patients remained assymptomatic throughout the study. Regarding the pulmonary valve

  14. Refractory pulmonary edema secondary to severe aortic valvular stenosis - aortic valvuloplasty as bridge therapy to surgery

    International Nuclear Information System (INIS)

    Santiago, Salazar; Hanna, Franklin; Capasso, Aminta

    2009-01-01

    Aortic valve stenosis is a progressive disease; when it is severe and symptomatic has a bleak prognosis that affects adversely the patient survival. In these cases, the treatment of choice is valve replacement surgery that under certain circumstances can bear a huge risk that forces the physician to consider less aggressive management alternatives to solve the problem. The case of a 65 years old male with severe aortic valve stenosis is reported. He developed pulmonary edema refractory to medical treatment that was solved by aortic valvuloplasty as bridge therapy to surgery.

  15. Diagnostic Value of Selected Echocardiographic Variables to Identify Pulmonary Hypertension in Dogs with Myxomatous Mitral Valve Disease.

    Science.gov (United States)

    Tidholm, A; Höglund, K; Häggström, J; Ljungvall, I

    2015-01-01

    Pulmonary hypertension (PH) is commonly associated with myxomatous mitral valve disease (MMVD). Because dogs with PH present without measureable tricuspid regurgitation (TR), it would be useful to investigate echocardiographic variables that can identify PH. To investigate associations between estimated systolic TR pressure gradient (TRPG) and dog characteristics and selected echocardiographic variables. 156 privately owned dogs. Prospective observational study comparing the estimations of TRPG with dog characteristics and selected echocardiographic variables in dogs with MMVD and measureable TR. Tricuspid regurgitation pressure gradient was significantly (P modeled as linear variables LA/Ao (P modeled as second order polynomial variables: AT/DT (P = .0039) and LVIDDn (P value for the final model was 0.45 and receiver operating characteristic curve analysis suggested the model's performance to predict PH, defined as 36, 45, and 55 mmHg as fair (area under the curve [AUC] = 0.80), good (AUC = 0.86), and excellent (AUC = 0.92), respectively. In dogs with MMVD, the presence of PH might be suspected with the combination of decreased PA AT/DT, increased RVIDDn and LA/Ao, and a small or great LVIDDn. Copyright © 2015 The Authors Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  16. Pregnancy Complicated with Maternal Pulmonary Hypertension and Placenta Accreta

    Directory of Open Access Journals (Sweden)

    Jeng-Hsiu Hung

    2007-06-01

    Full Text Available Pregnancy is contraindicated in cases of maternal pulmonary hypertension, a highly morbid disease affecting young women of childbearing age. The rate of heart failure increases gradually with the severity of pulmonary hypertension. In certain instances, the severity of maternal pulmonary hypertension in rheumatic heart diseases can be higher than in congenital heart diseases. Placenta accreta is an important cause of bleeding in the second half of pregnancy and in labor. In severe cases, hysterectomy is the only way to manage the bleeding during cesarean section. A 33-year-old gravida, G2P0AA1, suffering from rheumatic heart disease with mitral valve stenosis and pulmonary hypertension, was referred to our high-risk pregnancy center at 10+3 weeks of gestation due to lower abdominal pain and brownish vaginal bleeding. She had received 2 mitral valve replacements in Shenzhen, China, at the ages of 22 and 26, respectively. Ultrasound scan of the abdomen at 12+2 gestational weeks showed that the internal cervix was completely covered with the placenta, and a retroplacental hypoechoic space measuring 35 × 13 mm was observed at the upper posterior margin of the placenta. On color Doppler scan, an area of lacunar lake flow was observed in the hypoechoic space of the placenta and a spiral artery with low blood flow resistance was detected. The pulsation of the placental flow was synchronized with the maternal pulse rate. Team specialists, including neonatologists, pulmonary physicians, pediatric cardiologists, hema-tologists, anesthesiologists, psychiatrists and social workers, as well as high-risk obstetricians were consulted in an effort to minimize fetal and maternal morbidity and mortality. At 29+2 weeks, the patient developed preeclampsia and delivered a healthy newborn by cesarean section, the uterus being preserved by square compression sutures. The gravida tolerated the procedures and was discharged in stable condition.

  17. Clinical challenges of persistent pulmonary air-leaks--case report.

    Science.gov (United States)

    van Zeller, M; Bastos, P; Fernandes, G; Magalhães, A

    2014-01-01

    Air leaks are a common problem after pulmonary resection and can be a source of significant morbidity and mortality. The authors describe the case of a 68-year-old male patient who presented with a persistent air-leak after pulmonary resection. Watchful waiting, surgical procedures, as well as medical therapy like pleurodesis and implantation of endobronchial one-way valves on the bronchial segments identified using systematic occlusion of the bronchial segments, were all tried unsuccessfully. During that time the patient remained hospitalized with a chest tube. The instillation of methylene blue through the chest tube was used to identify the segments leading to the persistent air-leak; this enabled successful endobronchial valve placement which sufficiently reduced the size of the air-leak so that the chest tube could be removed. Nonsurgical approaches seem promising and, for some patients may be the only treatment option after all conventional treatments have failed or are considered too high risk. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.

  18. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  19. Age-related changes in biomechanical properties of transgenic porcine pulmonary and aortic conduits

    International Nuclear Information System (INIS)

    Wilczek, Piotr; Malota, Zbigniew; Lesiak, Anna; Niemiec-Cyganek, Aleksandra; Kubin, Barbara; Nozynski, Jerzy; Mzyk, Aldona; Gramatyka, Michalina; Slomski, Ryszard; Wilczek, Grazyna; Opiela, Jolanta

    2014-01-01

    The limitations associated with conventional valve prosthesis have led to a search for alternatives. One potential approach is tissue engineering. Most tissue engineering studies have described the biomechanical properties of heart valves derived from adult pigs. However, because one of the factors affecting the function of valve prosthesis after implantation is appropriate sizing for a given patient, it is important to evaluate the usefulness of a heart valve given the donor animal’s weight and age. The aim of this study was to evaluate how the age of a pig can influence the biomechanical and hemodynamical properties of porcine heart valve prosthesis after acellularization. Acellular porcine aortic and pulmonary valve conduits were used. Hearts were harvested from animals differing in weight and age. The biomechanical properties of the valves were then characterized using a uniaxial tensile test. Moreover, computer simulations based on the finite element method (FEM) were used to study the influence of biomechanical properties on the hemodynamic conditions. Studying biomechanical and morphological changes in porcine heart valve conduits according to the weight and age of the animals can be valuable for developing age-targeted therapy using tissue engineering techniques. (paper)

  20. Management of tricuspid valve regurgitation: Position statement of the European Society of Cardiology Working Groups of Cardiovascular Surgery and Valvular Heart Disease.

    Science.gov (United States)

    Antunes, Manuel J; Rodríguez-Palomares, José; Prendergast, Bernard; De Bonis, Michele; Rosenhek, Raphael; Al-Attar, Nawwar; Barili, Fabio; Casselman, Filip; Folliguet, Thierry; Iung, Bernard; Lancellotti, Patrizio; Muneretto, Claudio; Obadia, Jean-François; Pierard, Luc; Suwalski, Piotr; Zamorano, Pepe

    2017-12-01

    Tricuspid regurgitation (TR) is a very frequent manifestation of valvular heart disease. It may be due to the primary involvement of the valve or secondary to pulmonary hypertension or to the left-sided heart valve disease (most commonly rheumatic and involving the mitral valve). The pathophysiology of secondary TR is complex and is intrinsically connected to the anatomy and function of the right ventricle. A systematic multimodality approach to diagnosis and assessment (based not only on the severity of the TR but also on the assessment of annular size, RV function and degree of pulmonary hypertension) is, therefore, essential. Once considered non-important, treatment of secondary TR is currently viewed as an essential concomitant procedure at the time of mitral (and, less frequently, aortic valve) surgery. Although the indications for surgical management of severe TR are now generally accepted (Class I), controversy persists concerning the role of intervention for moderate TR. However, there is a trend for intervention in this setting, especially at the time of surgery for left-sided heart valve disease and/or in patients with significant tricuspid annular dilatation (Class IIa). Currently, surgery remains the best approach for the interventional treatment of TR. Percutaneous tricuspid valve intervention (both repair and replacement) is still in its infancy but may become a reliable option in future, especially for high-risk patients with isolated primary TR or with secondary TR related to advanced left-sided heart valve disease. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Acute Pulmonary Edema Caused by a Giant Atrial Myxoma

    Directory of Open Access Journals (Sweden)

    Andrea Fisicaro

    2013-01-01

    Full Text Available Atrial myxoma is the most common primary cardiac tumor. Its clinical presentation spreads from asymptomatic incidental mass to serious life-threatening cardiovascular complications. We report the case of a 44-year-old man with evening fever and worsening dyspnea in the last weeks, admitted to our hospital for acute pulmonary edema. The cardiac auscultation was very suspicious for mitral valve stenosis, but the echocardiography revealed a huge atrial mass with a diastolic prolapse into mitral valve orifice causing an extremely high transmitral gradient pressure. Awareness of this uncommon acute presentation of atrial myxoma is necessary for timely diagnosis and prompt surgical intervention.

  2. Anuloplastia de homoenxerto pulmonar criopreservado com anel de Delrin na atresia pulmonar com comunicação interventricular Annuloplasty of cryopreserved pulmonary homograft with Delrin stent in pulmonary atresia with ventricular septal defect

    Directory of Open Access Journals (Sweden)

    Ulisses Alexandre Croti

    2007-05-01

    Full Text Available Criança de seis anos portadora de atresia pulmonar com comunicação interventricular, submetida a correção total com um ano, empregando monoválvula de pericárdio bovino na reconstrução da via de saída do ventrículo direito. Evoluiu com importante regurgitação valvar pulmonar (RVP e disfunção do ventrículo direito. Na reoperação foi implantado homoenxerto pulmonar criopreservado (HPC com anuloplastia, utilizando anel de Delrin com o intuito de evitar distorção geométrica do conduto. Após dois anos, o ecocardiograma, semelhante ao pós-operatório imediato, demonstra RVP discreta e função ventricular direita normal, sugerindo que essa manobra pode ser utilizada como coadjuvante para otimizar o resultado do implante do HPC.A six-year-old child was suffering from pulmonary atresia with ventricular septal defect after a total correction at 1 year of age using a bovine pericardial monocusp valve in the reconstruction of the right ventricle outflow tract. The infant evolved with significant pulmonary valve regurgitation (PVR and right ventricle dysfunction. On reoperation, a cryopreserved pulmonary homograft (CPH was implanted with annuloplasty utilizing a Delrin ring with the aim of avoiding geometric distortion of the vessel. After two years, an echocardiogram proved a similar state to the immediate postoperative period with slight pulmonary valve regurgitation and normal right ventricular function suggesting that this maneuver may be used as coadjuvant treatment to optimize the result of CPH implantation.

  3. Optimal timing of pulmonary valve replacement in tetralogy of Fallot

    NARCIS (Netherlands)

    Straten, Alexander van

    2008-01-01

    Over the past decades, life expectancy in patients with congenital heart disease has increased dramatically. However, serious complications may develop late after total repair in infancy. These complications are usually the result of longstanding pulmonary regurgitation which leads tot dilatation of

  4. Monophasic Synovial Sarcoma Presenting as Mitral Valve Obstruction

    OpenAIRE

    Chokesuwattanaskul, Warangkana; Terrell, Jason; Jenkins, Leigh Ann

    2010-01-01

    We report the case of a 26-year-old man who experienced progressive left-sided chest pain and 2 episodes of near-syncope. Studies revealed a 15-cm mass in the upper left lung, a 10-cm mass in the medial base of the left lung, and a 5-cm left atrial mass that involved the left lung, infiltrated the left pulmonary vein, and prolapsed into the mitral valve, causing intermittent obstruction. The patient underwent surgical excision of the left atrial tumor. Pathologic evaluation confirmed the diag...

  5. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  6. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  7. Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis

    Directory of Open Access Journals (Sweden)

    Kiessling Arndt H

    2011-10-01

    Full Text Available Abstract Background We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. Methods One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20 or mechanical prosthesis (MP, Edwards Mira n = 20 in group 1 (age 75. Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. Results In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005 with comparable left ventricular mass regression (LVMR. Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81. The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06. Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Conclusions Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs.

  8. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  9. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  10. Chronic obstructive pulmonary disease in patients admitted with heart failure

    DEFF Research Database (Denmark)

    Iversen, K K; Kjaergaard, J; Akkan, D

    2008-01-01

    OBJECTIVE: Chronic obstructive pulmonary disease (COPD) is an important differential diagnosis in patients with heart failure (HF). The primary aims were to determine the prevalence of COPD and to test the accuracy of self-reported COPD in patients admitted with HF. Secondary aims were to study...... valve. CONCLUSION: Chronic obstructive pulmonary disease is frequent in patients admitted with HF and self-reported COPD only identifies a minority. The prevalence of COPD was high in both patients with systolic and nonsystolic HF....... a possible relationship between right and left ventricular function and pulmonary function. DESIGN: Prospective substudy. SETTING: Systematic screening at 11 centres. SUBJECTS: Consecutive patients (n = 532) admitted with HF requiring medical treatment with diuretics and an episode with symptoms...

  11. Gerbode defect following endocarditis and misinterpreted as severe pulmonary arterial hypertension

    Directory of Open Access Journals (Sweden)

    Allajbeu Iris

    2010-09-01

    Full Text Available Abstract A Gerbode -type defect is a ventricular septal defect communicating directly between the left ventricle and right atrium. It is usually congenital, but rarely is acquired, as a complication of endocarditis. This can be anatomically possible because the normal tricuspid valve is more apically displaced than the mitral valve. However, identification of an actual communication is often extremely difficult, so a careful and meticulous echocardiogram should be done in order to prevent echocardiographic misinterpretation of this defect as pulmonary arterial hypertension. The large systolic pressure gradient between the left ventricle and the right atrium would expectedly result in a high velocity systolic Doppler flow signal in right atrium and it can be sometimes mistakably diagnosed as tricuspid regurgitant jet simulating pulmonary arterial hypertension. We present a rare case of young woman, with endocarditis who presented with severe pulmonary arterial hypertension. The preoperative diagnosis of left ventricle to right atrial communication (acquired Gerbode defect was suspected initially by echocardiogram and confirmed at the time of the surgery. A point of interest, apart from the diagnostic problem, was the explanation for its mechanism and presentation. The probability of a bacterial etiology of the defect is high in this case.

  12. Fungal prosthetic valve endocarditis with mycotic aneurysm: Case report.

    Science.gov (United States)

    Brandão, Mariana; Almeida, Jorge; Ferraz, Rita; Santos, Lurdes; Pinho, Paulo; Casanova, Jorge

    2016-09-01

    Fungal prosthetic valve endocarditis is an extremely severe form of infective endocarditis, with poor prognosis and high mortality despite treatment. Candida albicans is the most common etiological agent for this rare but increasingly frequent condition. We present a case of fungal prosthetic valve endocarditis due to C. albicans following aortic and pulmonary valve replacement in a 38-year-old woman with a history of surgically corrected tetralogy of Fallot, prior infective endocarditis and acute renal failure with need for catheter-based hemodialysis. Antifungal therapy with liposomal amphotericin B was initiated prior to cardiac surgery, in which the bioprostheses were replaced by homografts, providing greater resistance to recurrent infection. During hospitalization, a mycotic aneurysm was diagnosed following an episode of acute arterial ischemia, requiring two vascular surgical interventions. Despite the complications, the patient's outcome was good and she was discharged on suppressive antifungal therapy with oral fluconazole for at least a year. The reported case illustrates multiple risk factors for fungal endocarditis, as well as complications and predictors of poor prognosis, demonstrating its complexity. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. P Wave Dispersion is Increased in Pulmonary Stenosis

    Directory of Open Access Journals (Sweden)

    Namik Ozmen

    2006-01-01

    Full Text Available Aim: The right atrium pressure load is increased in pulmonary stenosis (PS that is a congenital anomaly and this changes the electrophysiological characteristics of the atria. However, there is not enough data on the issue of P wave dispersion (PWD in PS. Methods: Forty- two patients diagnosed as having valvular PS with echocardiography and 33 completely healthy individuals as the control group were included in the study. P wave duration, p wave maximum (p max and p minimum (p min were calculated from resting electrocariography (ECG obtained at the rate of 50 mm/sec. P wave dispersion was derived by subtracting p min from p max. The mean pressure gradient (MPG at the pulmonary valve, structure of the valve and diameters of the right and left atria were measured with echocardiography. The data from two groups were compared with the Mann-Whitney U test and correlation analysis was performed with the Pearson correlation technique. Results: There wasn’t any statistically significance in the comparison of age, left atrial diameter and p min between two groups. While the MPG at the pulmonary valve was 43.11 ± 18.8 mmHg in PS patients, it was 8.4 ± 4.5 mmHg in the control group. While p max was 107.1 ± 11.5 in PS group, it was 98.2 ± 5.1 in control group (p=0.01, PWD was 40.4 ± 1.2 in PS group, and 27.2 ± 9.3 in the control group (p=0.01Moreover, while the diameter of the right atrium in PS group was greater than that of the control group, (38.7 ± 3.9 vs 30.2 ± 2.5, p=0.02. We detected a correlation between PWD and pressure gradient in regression analysis. Conclusion: P wave dispersion and p max are increased in PS. While PWD was correlated with the pressure gradient that is the degree of narrowing, it was not correlated with the diameters of the right and left atria.

  14. The Ross II procedure: pulmonary autograft in the mitral position.

    Science.gov (United States)

    Athanasiou, Thanos; Cherian, Ashok; Ross, Donald

    2004-10-01

    The surgical management of mitral valve disease in women of childbearing age, young patients, and children with congenital mitral valve defects is made difficult by the prospect of lifelong anticoagulation. We suggest the use of a pulmonary autograft in the mitral position (Ross II procedure) as an alternative surgical technique. We present a review of the literature, historical perspectives, indications, selection criteria, and surgical technique for the Ross II procedure. Our literature search identified 14 studies that reported results from the Ross II operation. Performed in 103 patients, the overall in-hospital mortality was 7 (6.7%), with a late mortality of 10 (9%). Although further research is needed, current evidence suggests the Ross II operation is a valuable alternative in low-risk young patients where valve durability and the complication rate from other procedures is unsatisfactory and anticoagulation not ideal.

  15. Isolated pulmonic valve endocarditis presenting as neck pain

    Directory of Open Access Journals (Sweden)

    Aditya Goud

    2015-12-01

    Full Text Available We discuss a unique case of a 52-year-old man with no history of intravenous drug use or dental procedures who presented with neck pain, 2 weeks of fevers, chills, night sweats, cough, and dyspnea found to have isolated pulmonic valve (PV endocarditis. The patient did not have an associated murmur, which is commonly seen in right-sided infectious endocarditis. A transthoracic echocardiogram showed a thickened PV leaflet, with subsequent transesophageal echocardiogram showing a PV mass. Speciation of blood cultures revealed Streptococcus oralis. In right-sided infective endocarditis, usually the tricuspid valve is involved; however, in our case the tricuspid valve was free of any mass or vegetation. The patient did meet Duke criteria and was thus started on long-term intravenous antibiotics for infectious endocarditis. The patient's symptoms quickly improved with antibiotics. A careful history and evaluating the patient's risk factors are key in earlier detection of infective endocarditis (IE. Because of early detection and a high index of suspicion, the patient had no further complications and did not require any surgery. In conclusion, clinical suspicion of right-sided IE should be high in patients who present with persistent fevers and pulmonary symptoms in order to reduce the risk of complications, and to improve outcomes.

  16. Evaluation of regional pulmonary blood flow in mitral valvular heart disease using single-pass radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Chang-Soon Koh; Byung Tae Kim; Myung Chul Lee; Bo Yeon Cho

    1982-01-01

    Pulmonary hypertension in mitral valvular cardiac disease has been evaluated in 122 patients by a modified upper lung/lower count ratio using single-pass radionuclide angiocardiography. The mean upper lung/lower lung radio correlates well with pulmonary artery mean (r=0.483) and wedge pressure (r=0.804). After correction surgery of the cardiac valve, the ratio decreases and returns to normal range in patients judged clinically to have good surgical benifit. This modified method using single-pass technique provides additional simple, reproducible and nontraumatic results of regional pulmonary blood flow and appears to be correlated with the degree of pulmonary hypertension in mitral heart disease

  17. Endobronchial Valves for Endoscopic Lung Volume Reduction : Best Practice Recommendations from Expert Panel on Endoscopic Lung Volume Reduction

    NARCIS (Netherlands)

    Slebos, Dirk-Jan; Shah, Pallav L.; Herth, Felix J. F.; Valipour, Arschang

    Endoscopic lung volume reduction (ELVR) is being adopted as a treatment option for carefully selected patients suffering from severe emphysema. ELVR with the one-way endobronchial Zephyr valves (EBV) has been demonstrated to improve pulmonary function, exercise capacity, and quality of life in

  18. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  19. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  20. [Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].

    Science.gov (United States)

    Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir

    2017-01-01

    Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.

  1. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  2. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  3. 28. Critical pulmonary valve stenosis: Medical management beyond balloon dilation

    Directory of Open Access Journals (Sweden)

    Muhammad Arif Khan

    2015-10-01

    Conclusion: Phentolamine and/or Captopril have a therapeutic role in neonates with critical PVS who remain oxygen dependent after balloon dilation. Both medicationslead to vasodilatation of pulmonary and systemic vascularity. They facilitate inflowto the right ventricle. Right to left shunt across a PFO or/ ASD minimizesand saturation improves leading to a significantreduction in length of hospitalization.

  4. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  5. [MitraClip® for treatment of tricuspid valve insufficiency].

    Science.gov (United States)

    Pfister, R; Baldus, S

    2017-11-01

    Tricuspid valve regurgitation is frequently found as a result of right ventricular remodeling due to advanced left heart diseases. Drug treatment is limited to diuretics and the cardiac or pulmonary comorbidities. Due to the high risk only a small percentage of patients are amenable to surgical treatment of tricuspid regurgitation in those who undergo left-sided surgery for other reasons. Catheter-based procedures are an attractive treatment alternative, particularly since the strong prognostic impact of tricuspid regurgitation suggests an unmet need of treatment, independent of the underlying heart disease. A vast amount of clinical experience exists for the MitraClip system for treatment of mitral regurgitation. A first case series shows that the application for treatment of tricuspid regurgitation is technically feasible, seems to be safe and the degree of valve regurgitation can be reduced. In this review the background of tricuspid regurgitation treatment is summarized and first experiences and perspectives with the MitraClip system are assessed.

  6. Disc dislodgment in Björk Shiley mitral valve prosthesis: two successfully operated cases.

    Science.gov (United States)

    Dubernet, J; Irarrázaval, M J; Urzúa, J; Maturana, G; Morán, S; Lema, G; Asenjo, F; Fajuri, A

    1986-02-01

    Two patients with Björk Shiley mitral valve replacement had migration and embolization of the occluding disc. One patient suffered migration of the disc a few hours after surgery and the other had a strut fracture with disc translocation six years after the initial operation. Clinical signs in both cases were pulmonary edema, cardiogenic shock, and absence of prosthetic sounds. Both patients were reoperated on an emergency basis, recovering after a complicated postoperative course. They are on functional Class I, 8 and 1 years later, respectively, with their dislodged discs still in the abdominal aorta. The only hope for survival in these patients is emergency reoperation, once the prosthetic mitral valve dysfunction is confirmed.

  7. A floating right heart thrombus in transit across tricuspid valve causing an endocardial friction rub

    Directory of Open Access Journals (Sweden)

    Babu Kanjirakadavath

    2013-07-01

    Full Text Available We report a 42-year-old lady on combined oral contraceptive pills with deep venous thrombosis and mild pulmonary embolism, who developed shock, while being treated with heparin. On auscultation, there was an unexpected loud, superficial, squeaky, triphasic friction rub over the left lower parasternal area. Simultaneous echocardiogram revealed a large serpiginous, freely floating mass in right atrium, prolapsing freely to right ventricular inlet across the tricuspid valve. The endocardial friction rub persisted for about 24 h as long as the thrombus was intracardiac and disappeared when the thrombus disappeared from right heart, occluding the proximal left pulmonary artery. She died due to shock awaiting surgery. We highlight that such a rub in a patient with deep venous thrombosis, though rare, may be an important clue to impending pulmonary embolism.

  8. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  9. In vivo canine studies of a Sinkhole valve and vascular graft coated with biocompatible PU-PEO-SO3.

    Science.gov (United States)

    Han, D K; Lee, K B; Park, K D; Kim, C S; Jeong, S Y; Kim, Y H; Kim, H M; Min, B G

    1993-01-01

    PU-PEO-SO3 was applied as a coating material over a newly designed Sinkhole bileaflet PU heart valve and a porous PU vascular graft. Performance and biocompatibility were evaluated using an in vivo canine shunt system between the right ventricle and pulmonary artery. The survival periods in three implantations were 14, 24, and 39 days, during which no mechanical failure occurred in any Sinkhole valve or vascular graft. Scanning electron microscopy (SEM) studies demonstrated much less platelet adhesion and thrombus formation on PU-PEO-SO3 grafts than on PU vascular grafts. Cracks in the valve leaflet were occasionally observed on PU surfaces, but not on PU-PEO-SO3. After a 39 day implantation, calcium deposition on vascular grafts was decreased as compared with valve leaflets, and calcification on PU-PEO-SO3 was much lower than on PU. These results suggest that Sinkhole valves and vascular grafts are promising, and PU-PEO-SO3 as a coating material is more blood compatible, biostable, and calcification resistant in vivo than in untreated PU.

  10. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  11. [Prediction of the efficiency of endoscopic lung volume reduction by valves in severe emphysema].

    Science.gov (United States)

    Bocquillon, V; Briault, A; Reymond, E; Arbib, F; Jankowski, A; Ferretti, G; Pison, C

    2016-11-01

    In severe emphysema, endoscopic lung volume reduction with valves is an alternative to surgery with less morbidity and mortality. In 2015, selection of patients who will respond to this technique is based on emphysema heterogeneity, a complete fissure visible on the CT-scan and absence of collateral ventilation between lobes. Our case report highlights that individualized prediction is possible. A 58-year-old woman had severe, disabling pulmonary emphysema. A high resolution thoracic computed tomography scan showed that the emphysema was heterogeneous, predominantly in the upper lobes, integrity of the left greater fissure and no collateral ventilation with the left lower lobe. A valve was inserted in the left upper lobe bronchus. At one year, clinical and functional benefits were significant with complete atelectasis of the treated lobe. The success of endoscopic lung volume reduction with a valve can be predicted, an example of personalized medicine. Copyright © 2016 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  12. Prevalence, Predictors and Clinical Outcome of Residual Pulmonary Hypertension Following Tricuspid Annuloplasty.

    Science.gov (United States)

    Chen, Yan; Liu, Ju-Hua; Chan, Daniel; Sit, Ko-Yung; Wong, Chun-Ka; Ho, Kar-Lai; Ho, Lai-Ming; Zhen, Zhe; Lam, Yui-Ming; Lau, Chu-Pak; Au, Wing-Kok; Tse, Hung-Fat; Yiu, Kai-Hang

    2016-07-22

    Tricuspid annuloplasty is increasingly performed during left heart valve surgery, but the long-term clinical outcome postoperatively is not satisfactory. The aim of this study was to determine whether residual pulmonary hypertension (PHT) contributes to the adverse outcome. One-hundred thirty-seven patients (age 61±11 years; men, 30%) who underwent tricuspid annuloplasty during left-side valve surgery were enrolled. The mean pulmonary artery systolic pressure before surgery was 49±13 mm Hg and 32±15 mm Hg following surgery. Patients were divided into 3 groups according to postoperative pulmonary artery systolic pressure: no residual PHT (n=78, 57%), mild residual PHT (n=43, 31%), or significant residual PHT (n=16, 12%). A preoperative larger right ventricular (RV) geometry and tricuspid valve tethering area were associated with mild or significant residual PHT. A total of 24 adverse events (20 heart failures and 4 cardiovascular deaths) occurred during a median follow-up of 25 months. Kaplan-Meier survival curve demonstrated that patients with significant residual PHT had the highest percentage of adverse events followed by those with mild residual PHT. Patients with no residual PHT had a very low risk of adverse events. Multivariable Cox regression analysis revealed that both mild (hazard ratio=4.94; 95% CI =1.34-18.16; P=0.02) and significant residual PHT (hazard ratio=8.67; 95% CI =2.43-30.98; P<0.01) were independent factors associated with adverse events. The present study demonstrated that 43% of patients who underwent tricuspid annuloplasty had residual PHT. The presence of mild or significant residual PHT was associated with adverse events in these patients. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  13. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  14. Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT: a non-surgical method of lung volume reduction

    Directory of Open Access Journals (Sweden)

    Noppen Marc

    2007-07-01

    Full Text Available Abstract Background Lung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently, less invasive bronchoscopic approaches have been designed to utilize these principles while avoiding the associated perioperative risks. The Endobronchial Valve for Emphysema PalliatioN Trial (VENT posits that occlusion of a single pulmonary lobe through bronchoscopically placed Zephyr® endobronchial valves will effect significant improvements in lung function and exercise tolerance with an acceptable risk profile in advanced emphysema. Methods The trial design posted on Clinical trials.gov, on August 10, 2005 proposed an enrollment of 270 subjects. Inclusion criteria included: diagnosis of emphysema with forced expiratory volume in one second (FEV1 100%; residual volume > 150% predicted, and heterogeneous emphysema defined using a quantitative chest computed tomography algorithm. Following standardized pulmonary rehabilitation, patients were randomized 2:1 to receive unilateral lobar placement of endobronchial valves plus optimal medical management or optimal medical management alone. The co-primary endpoint was the mean percent change in FEV1 and six minute walk distance at 180 days. Secondary end-points included mean percent change in St. George's Respiratory Questionnaire score and the mean absolute changes in the maximal work load measured by cycle ergometry, dyspnea (mMRC score, and total oxygen use per day. Per patient response rates in clinically significant improvement/maintenance of FEV1 and six minute walk distance and technical success rates of valve placement were recorded. Apriori response predictors based on quantitative CT and lung physiology were defined. Conclusion If endobronchial valves improve FEV1 and health status with an acceptable safety profile in advanced emphysema, they would offer a novel intervention for this progressive and

  15. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  16. Nanopatterned acellular valve conduits drive the commitment of blood-derived multipotent cells

    Directory of Open Access Journals (Sweden)

    Di Liddo R

    2016-10-01

    Full Text Available Rosa Di Liddo,1,2 Paola Aguiari,3 Silvia Barbon,1,2 Thomas Bertalot,1 Amit Mandoli,1 Alessia Tasso,1 Sandra Schrenk,1 Laura Iop,3 Alessandro Gandaglia,3 Pier Paolo Parnigotto,2 Maria Teresa Conconi,1,2 Gino Gerosa31Department of Pharmaceutical and Pharmacological Sciences, University of Padova, 2Foundation for Biology and Regenerative Medicine, Tissue Engineering and Signaling ONLUS, 3Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy Abstract: Considerable progress has been made in recent years toward elucidating the correlation among nanoscale topography, mechanical properties, and biological behavior of cardiac valve substitutes. Porcine TriCol scaffolds are promising valve tissue engineering matrices with demonstrated self-repopulation potentiality. In order to define an in vitro model for investigating the influence of extracellular matrix signaling on the growth pattern of colonizing blood-derived cells, we cultured circulating multipotent cells (CMC on acellular aortic (AVL and pulmonary (PVL valve conduits prepared with TriCol method and under no-flow condition. Isolated by our group from Vietnamese pigs before heart valve prosthetic implantation, porcine CMC revealed high proliferative abilities, three-lineage differentiative potential, and distinct hematopoietic/endothelial and mesenchymal properties. Their interaction with valve extracellular matrix nanostructures boosted differential messenger RNA expression pattern and morphologic features on AVL compared to PVL, while promoting on both matrices the commitment to valvular and endothelial cell-like phenotypes. Based on their origin from peripheral blood, porcine CMC are hypothesized in vivo to exert a pivotal role to homeostatically replenish valve cells and contribute to hetero- or allograft colonization. Furthermore, due to their high responsivity to extracellular matrix nanostructure signaling, porcine CMC could be useful for a preliminary

  17. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  18. Mitral valve prolapse in the ventriculogram: scintigraphic, electrocardiographic, and hemodynamic abnormalities

    International Nuclear Information System (INIS)

    Tebbe, U.; Schicha, H.; Neumann, P.; Voth, E.; Emrich, D.; Neuhaus, K.L.; Kreuzer, H.

    1985-01-01

    Patients with mitral valve prolapse (MVP) frequently have chest pain, which may be difficult to differentiate from angina pectoris in coronary artery disease (CAD). The authors performed resting and exercise ECGs, pulmonary arterial pressure measurements, radionuclide ventriculography (/sup 99m/technetium), and perfusion scintigrams ( 201 thallium) in 56 patients with angiographically proven MVP and no CAD. Pathological results were obtained in 31% of exercise ECGs, 33% of pulmonary arterial pressure measurements during exercise, 22% of radionuclide ventriculographies, and in 75% of thallium perfusion scintigrams. A significant correlation in pathological results was found only between exercise ECG and both radionuclide ventriculography and pulmonary arterial pressure measurements. Because of the high prevalence of false-positive perfusion scintigrams in patients with typical or atypical chest pain, the use of exercise 201 Tl imaging as a screening method to separate patients with MVP from those with CAD will not be appropriate. The variability of cardiac abnormalities in our patients with MVP and angiographically normal coronary arteries suggests that the MVP syndrome may represent a variable combination of metabolic, ischemic, or myopathic disorders

  19. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  20. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  1. Correlation of plasma endothelin-1 levels with pulmonary hypertension after inhaled nitric oxide therapy

    International Nuclear Information System (INIS)

    Razzaq, Z.; Naqvi, S.; Aslam, M.

    2009-01-01

    Variable response to inhaled nitric oxide (iNO) therapy in patients with mitral stenosis (MS) having pulmonary hypertension (PH) has been documented in early studies. The objectives of this study were to measure plasma Endothelin-1 (ET-1) levels in those patients and to correlate them with pulmonary vascular indices after iNO therapy. It was Quesi-experimental study. Methods: Thirty patients with mitral or mixed mitral and aortic valve disease with severe pulmonary hypertension and enrolled for valve replacement surgery were included. Before the replacement, baseline pulmonary vascular indices and cardiac output were recorded. After the surgery, 10 - 20 was in administered for 1 hour and all the parameters were again recorded. Patients were grouped into responders and non responders on the basis of % reduction in Pulmonary Vascular Resistance (PVR) after iNO therapy. Plasma ET-1 levels were measured in both groups by ELISA before and after the iNO therapy. Paired sample t-test was used to compare mean values for significance. The correlations between variables were then calculated by using Pearson's coefficient. Results: The plasma ET-1 levels were very high in all patients. They reduced in responders after iNO therapy; non-responders paradoxically showed significant increase in the levels of ET-1 after iNO therapy. Moreover, a positive correlation was observed in plasma ET-1 levels and post operative levels of PVR. Conclusion: The correlation of changes in PVR and plasma ET-1 levels in responders suggests that high plasma ET-1 is a key mediator of poor response in PH secondary to MS, after iNO therapy. (author)

  2. Mitral Valve Stenosis in Pregnancy and Its Effects on Maternal and Fetal Outcomes

    Directory of Open Access Journals (Sweden)

    İlker Gül

    2012-12-01

    Full Text Available Objective: Our aim is to determine the effect of mitral valvular disease on pregnancy follow up parameters and newborns. Material and Methods: We retrospectively reviewed the pregnant patients those were hospitalized because of mild-moderate mitral valve stenosis (n=16 between January 1998 and January 2011 in our center. Echocardiography was performed with regular intervals and the datas were recorded. Gestational age of delivery, type of delivery, general condition of newborn due to APGAR system were assessed. Values were compared with those of controls without any cardiac disease (n=16. Results: Mean mitral valve area, average mitral gradient and systemic pulmonary artery pressure were established 1.44+0.45 cm2, 5.2+1.5 mmHg ve 23+4.8 mmHg respectively in patients with mitral stenosis. Mean gestational age of delivery was 36.2±1.4 weeks (p=0.001 and mean fetal weight was 2646±431.1 g (p=0.016 in patients with mitral valve stenosis. These values were 38.7±2.12 weeks and 3056±212.13 gram respectively in control group. No significant difference was observed in terms of 1. and 5. APGAR scoring system among two groups. Conclusion: To optimize pregnancy outcomes, accurate diagnosis of the etiology, severity of valve disease and preconception evaluation are the main factors. Obstetrician should be careful in terms of intrauterine growth retardation and preterm delivery during pregnancy in patients with mitral valve stenosis.

  3. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  4. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography

    International Nuclear Information System (INIS)

    Bang, Ji Hyun; Park, Jeong-Jun; Goo, Hyun Woo

    2017-01-01

    There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation. To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation. In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated. In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03). Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with

  5. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Ji Hyun; Park, Jeong-Jun [Asan Medical Center, University of Ulsan College of Medicine, Divisions of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Goo, Hyun Woo [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2017-05-15

    There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation. To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation. In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated. In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03). Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with

  6. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  7. Where does the pulmonary artery catheter float: Transesophageal echocardiography evaluation

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2015-01-01

    Full Text Available Background: Pulmonary artery (PA catheter provides a variety of cardiac and hemodynamic parameters. In majority of the patients, the catheter tends to float in the right pulmonary artery (RPA than the left pulmonary artery (LPA. We evaluated the location of PA catheter with the help of transesophageal echocardiography (TEE to know the incidence of its localization. Three views were utilized for this purpose; midesophageal ascending aorta (AA short-axis view, modified mid esophageal aortic valve long-axis view, and modified bicaval view. Methods: We enrolled 135 patients undergoing elective cardiac surgery where both the PA catheter and TEE were to be used; for this prospective observational study. PA catheter was visualized by TEE in the above mentioned views and the degree of clarity of visualization by three views was also noted. Position of the PA catheter was further confirmed by a postoperative chest radiograph. Results: One patient was excluded from the data analysis. PA catheter was visualized in RPA in 129 patients (96% and in LPA in 4 patients (3%. In 1 patient, the catheter was visualized in main PA in the chest radiograph. The midesophageal AA short-axis, modified aortic valve long-axis, and modified bicaval view provided good visualization in 51.45%, 57.4%, and 62.3% patients respectively. Taken together, PA catheter visualization was good in 128 (95.5% patients. Conclusion: We conclude that the PA catheter has a high probability of entering the RPA as compared to LPA (96% vs. 3% and TEE provides good visualization of the catheter in RPA.

  8. Anticoagulation in pregnant females with mechanical heart valves

    International Nuclear Information System (INIS)

    Shafique, H.; Chaudhry, A.; Ayyub, M.

    2006-01-01

    To evaluate the complications and outcome of anticoagulation therapy in pregnant females with valvular heart diseases. All pregnant females with prosthetic heart valves admitted in Armed Forces Institute of Cardiology from Jan 2004 to Dec 2004 were included in this study Basic demographic data including age, duration of pregnancy and complications observed were recorded. Warfarin was replaced with un-fractionated heparin (UFH) in first trimester and after that warfarin was continued with a targeted INR between 2.0-3.0. At 36 weeks warfarin was stopped and UFH was added; however, if patient went into spontaneous labour before this then immediate caesarian section was performed and UFH was restarted 4-6 hours after delivery along with oral warfarin. Out of 21 patients, sixteen (76.1%) had mitral valve diseases and five (23.9%) had both mitral and atrial. Majority (42.3%)of patients were in age group 26-30 years. Eleven (52.2%) reported in 9th month of gestation. Complications observed were hypertension (1), transient ischaemic attacks (1), pulmonary embolism (1), haemoptysis (1) and abortion (1). All patients, except one had successful completion of pregnancy. No case of foetal abnormality was seen. In 76% patients, daily dose of warfarin was <5 mg. Thrombo-prophylaxis in pregnancy with warfarin and UFH with an INR of 2.0-3.0 is effective in preventing thrombotic complications in females with mechanical valves without resulting in increase hemorrhagic complications. (author)

  9. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  10. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  11. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  12. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  13. Bovine aortic arch and idiopathic pulmonary artery aneurysm associated with bronchial compression

    Directory of Open Access Journals (Sweden)

    Süleyman Sezai Yıldız

    2015-09-01

    Full Text Available The left common carotid artery originating from the brachiocephalic trunk is termed the bovine aortic arch. Although it is the third most-common normal variant found in 9% humans, the origin of this term remains unclear. Until now, It has not been reported in the literature bovine aortic arch togetherness with pulmonary aneurysm and bronchial compression. Herein, we present a case with bovine aorta arch and pulmonary artery aneurysm associated with bronchial compression, which is incidentally detected by X-ray film. A 56-year-old Caucasian female admitted to the cardiology clinic with complaint of chest pain. Physical examination was unremarkable. Blood biochemistry values and cardiac markers were in normal range. Chest radiography revealed a widened mediastinum and prominent pulmonary conus with no active pulmonary disease. A subsequent transthoracic echocardiography revealed left ventricular hypertrophy, left atrial enlargement (diameter: 41 mm, mild mitral and tricuspid valve insufficiency, dilatation of main pulmonary artery (parasternal short-axis view diameter: 33 mm, normal pulmonary artery pressure and normal left ventricular systolic function. Computed tomography revealed bovine aortic arch associated with pulmonary artery aneurysm (diameter: 53 mm. And left main bronch of trachea was critically squeezed by aortic arch. Aortic and pulmonary vascular anomalies should be considered in patients with chest pain. And, identification with imaging modalities is important for prevention of chronic and irreversible complications.

  14. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  15. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. All you need to know about the tricuspid valve: Tricuspid valve imaging and tricuspid regurgitation analysis.

    Science.gov (United States)

    Huttin, Olivier; Voilliot, Damien; Mandry, Damien; Venner, Clément; Juillière, Yves; Selton-Suty, Christine

    2016-01-01

    The acknowledgment of tricuspid regurgitation (TR) as a stand-alone and progressive entity, worsening the prognosis of patients whatever its aetiology, has led to renewed interest in the tricuspid-right ventricular complex. The tricuspid valve (TV) is a complex, dynamic and changing structure. As the TV is not easy to analyse, three-dimensional imaging, cardiac magnetic resonance imaging and computed tomography scans may add to two-dimensional transthoracic and transoesophageal echocardiographic data in the analysis of TR. Not only the severity of TR, but also its mechanisms, the mode of leaflet coaptation, the degree of tricuspid annulus enlargement and tenting, and the haemodynamic consequences for right atrial and right ventricular morphology and function have to be taken into account. TR is functional and is a satellite of left-sided heart disease and/or elevated pulmonary artery pressure most of the time; a particular form is characterized by TR worsening after left-sided valve surgery, which has been shown to impair patient prognosis. A better description of TV anatomy and function by multimodality imaging should help with the appropriate selection of patients who will benefit from either surgical TV repair/replacement or a percutaneous procedure for TR, especially among patients who are to undergo or have undergone primary left-sided valvular surgery. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Pulmonary artery intravascular abscess: A rare complication of incomplete infective endocarditis treatment in the setting of injection drug use

    Directory of Open Access Journals (Sweden)

    Simran Gupta

    Full Text Available Infective endocarditis (IE is a serious complication of injection drug use. Right-sided IE encompasses 5–10% of all IE cases, with the majority involving the tricuspid valve (TV. The predominant causal organism is Staphylococcus aureus. Most cases of right-sided IE can be successfully treated with antimicrobials, but approximately 5–16% require eventual surgical intervention. We report the case of a 36-year-old female with active injection drug use who developed methicillin-sensitive Staphylococcus aureus IE of the tricuspid valve. Associated with poor adherence to medical therapy as a consequence of opioid addiction, she developed septic emboli to the lungs and an intravascular abscess in the left main pulmonary artery. These long-term potentially fatal, sequelae of incompletely treated IE require surgical intervention, as medical therapy is unlikely to be sufficient. Surgical management may involve TV replacement, pulmonary artery resection, and pneumonectomy. Prevention of these complications may have been achieved by concurrent opioid addiction therapy. An intravascular pulmonary artery abscess is a novel complication of advanced IE that has not been previously reported. This complication likely arose due to incomplete IE treatment as a consequence of opioid addiction, highlighting the need for concurrent addiction management. Intravenous antimicrobial therapy is likely not adequate, and surgical intervention, including pulmonary artery resection and pneumonectomy may be necessary. Keywords: Pulmonary artery abscess, Infective endocarditis, Injection drug use, Opioid use disorder

  18. Emergency aortic valve replacement and Caesarian section in a primigravida with severe aortic stenosis: a case report.

    Science.gov (United States)

    Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P

    2011-01-01

    Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).

  19. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  20. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  1. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  2. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  3. Reconstituição da valva pulmonar e via de saída do ventrículo direito, com prótese bivalvular e prótese tubular valvada de tronco pulmonar de porco: estudo experimental e aplicação clínica Pulmonary valve and right ventricular oulet tract reconstruction with biovalvular prostheses and valved tubular prostheses of the pig pulmonary artery: experimental study and clinical application

    Directory of Open Access Journals (Sweden)

    Miguel A Maluf

    1993-03-01

    aplicação clínica da prótese bivalvular foi realizada em 3 pacientes portadores de t. de Fallot associada a hipoplasía do anel pulmonar (2 casos e agenesia da valva pulmonar (1 caso, com idades de 16, 2 e 7 anos. Após evolução de 3 a 10 meses, os gradientes variaram entre 10 mmHg e 20 mmHg e discreta insuficiência pulmonar valvar ao estudo ecodopplercardiográfico. A prótese tubular valvar foi implantada em 2 pacientes portadores de atresia pulmonar associada a comunicação interventricular (CIV e outro a transposição corrigida das grandes artérias (TCGA associada a GIV e estenose subpulmonar, com idades de 10 e 6 anos, respectivamente. Após evolução de 5 a 12 meses, foram detectados suficiência da valva pulmonar, gradientes entre 15 mmHg e 18 mmHg, sem sinais de calcificação. Apesar de se considerar aceitáveis os resultados desta experiência, a ampliação das indicações deverá ser feita com cautela, até o melhor conhecimento da resistência da prótese a calcificação, infecção, obstrução e rotura.Obstruction of the right ventricle outlet tract (RVOT has been the object of arguments regarding its surgical correction, while there are different criteria for reconstruction. Thus two kinds of prostheses were developed from the pig pulmonary trunk (PT. 1 One with two valves of the pulmonary valve (PV, named bivalvular graft, and could be used for correction of Fallot with pulmonary ring hypoplasia. 2 The other, with a tubular form, containing the pig PV itself and named valved conduit, could be used in RVOT reconstruction for patients with pulmonary atresia (PA. These prostheses were tested in an experimental model: implant of the bivalvular graft was performed in 16 sheep with the aid of extracorporeal circulation (ECC. The surgical technique consisted of resection of the two valves of the PV and of the anterior wall of the infundibulum; this condition was similar to Fallot correction. Implant of the valvular conduit was carried out in 12

  4. [Nitrid oxide, levosimendan and sildenafile in a patient with right ventricle dysfunction and severe pulmonary hypertension after cardiac surgery].

    Science.gov (United States)

    Aleixandre, L; Cortell, J; Vicente, R; Herrera, P; Loro, J M; Valera, F

    2014-11-01

    Pulmonary hypertension (PHT) and the resulting right ventricle dysfunction are important risk factors in patients who undergo cardiac surgery. The treatment of PHT and right ventricle dysfunction should be focused on maintaining the correct right ventricle after load, improving right ventricle function and reducing the right ventricle pre-load and therefore reducing pulmonary vascular resistance by means of vasodilators. A combined therapy of vasodilators and medicines which have different mechanisms of action, is becoming an option for the treatment of PHT. We present a 65 year old woman that suffered from mitral regurgitation, aortic valve disease, tricuspid and ascending aortic dilation with 115mmHg of pulmonary artery pressure (by ultrasound evaluation). The patient was operated on of mitral, aortic valve and tricuspid plastia and proximal aortic artery plastia as well. Previosly to surgery the patient suffered right ventricle dysfunction and PHT and was treated with nitric oxide, intravenous sildenafil and levosimendan. Subsequent evolution was satisfactory, PHT being controlled, without arterial hypotension nor respiratory alterations. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  6. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  7. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  8. Detection of patent ductus arteriosus with intraoperative transesophageal echocardiography in a patient undergoing closure of coronary artery to pulmonary artery fistula.

    Science.gov (United States)

    Miyata, Yuka; Hayashi, Yukio

    2017-01-01

    Coronary artery to pulmonary artery fistula is an unusual vascular anomaly, and the shunt ratio of this fistula is usually small. We report anesthetic management of a 55-year-old female with annuloaortic ectasia, aortic valve regurgitation, and coronary artery to pulmonary artery fistula undergoing radical repair. We calculated the left-to-right shunt ratio after placement of a pulmonary artery catheter and found that the ratio was unexpectedly high. Thus, we explored the presence of another shunt by intraoperative transesophageal echocardiography and found patent ductus arteriosus undiagnosed before operation. A combination of a pulmonary artery catheter and transesophageal echocardiography is useful to explore the presence of another shunt, such as patent ductus arteriosus during anesthesia.

  9. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  10. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  11. Pulmonary artery dissection in eight dogs with patent ductus arteriosus.

    Science.gov (United States)

    Scansen, Brian A; Simpson, Elaine M; López-Alvarez, Jordi; Thomas, William P; Bright, Janice M; Eason, Bryan D; Rush, John E; Dukes-McEwan, Joanna; Green, Henry W; Cunningham, Suzanne M; Visser, Lance C; Kent, Agnieszka M; Schober, Karsten E

    2015-06-01

    To describe a series of dogs with pulmonary artery dissection and patent ductus arteriosus (PDA). Eight dogs. Retrospective case series. Pulmonary artery dissection was diagnosed in 8 dogs, 3 were Weimaraners. Four dogs presented in left-sided congestive heart failure, 4 presented for murmur evaluation and without clinical signs, and 1 presented in right-sided congestive heart failure. In 7 dogs the dissection was first documented concurrent with a diagnosis of uncorrected PDA. In the other dog, with pulmonary valve stenosis and PDA, the dissection was observed on autopsy examination 17 months after balloon pulmonary valvuloplasty and ductal closure. Median age at presentation for the 7 dogs with antemortem diagnosis of pulmonary artery dissection was 3.5 years (range, 1.5-4 years). Three dogs had the PDA surgically ligated, 2 dogs did not undergo PDA closure, 1 dog failed transcatheter occlusion of the PDA with subsequent surgical ligation, 1 dog underwent successful transcatheter device occlusion of the PDA, and 1 dog had the PDA closed by transcatheter coil delivery 17 months prior to the diagnosis of pulmonary artery dissection. The 2 dogs that did not have the PDA closed died 1 and 3 years after diagnosis due to heart failure. Pulmonary artery dissection is a potential complication of PDA in dogs, the Weimaraner breed may be at increased risk, presentation is often in mature dogs, and closure of the PDA can be performed and appears to improve outcome. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  14. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  15. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  16. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  17. Functional valve assessment: the emerging role of cardiovascular magnetic resonance.

    Science.gov (United States)

    Shah, Dipan J

    2010-01-01

    The prevalence of valvular heart disease is increasing along with the life span of the population. In assessing individuals with valve disease, echocardiography is the primary imaging modality used by clinicians both for initial assessment and for longitudinal evaluation. Information regarding valve morphology and function, cardiac chamber size, wall thickness, ventricular function, and estimates of pulmonary artery pressures can be readily obtained and integrated to formulate an assessment of valve disease severity. In some instances, body habitus or the presence of coexisting lung disease may result in suboptimal acoustic windows on echocardiography, which may lead to technically difficult studies. Additionally, in some patients, information from clinical history and physical examination or other diagnostic tests may be discordant with echocardiographic findings. In these instances, there is a significant clinical role for cardiovascular magnetic resonance (CMR). The diagnostic capabilities of CMR have increased substantially over the past 20 years due to hardware and software advances. Today, CMR has a number of unique advantages over other imaging modalities - primarily, it provides a view of the entire heart without limitations from inadequate imaging windows or body habitus. Furthermore, CMR can obtain imaging data in any imaging plane prescribed by the scan operator, which makes it ideal for accurate investigation of all cardiac valves - aortic, mitral, pulmonic, and tricuspid. In addition, CMR for valve assessment is noninvasive, free of ionizing radiation, and in most instances does not require contrast administration. Since a comprehensive review of the role of CMR in all valve lesions is beyond the scope of this article, we will focus on the most common valvular indication for performance of clinical CMR techniques and an overview of selected validation and reproducibility studies. The objectives of a comprehensive CMR study for evaluating mitral

  18. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  19. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  20. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  1. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  2. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  3. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  4. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  5. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  6. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  7. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  8. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  9. Lung Perfusion SPECT: Application in a Patient With Tetralogy of Fallot and Suspected Pulmonary Thromboemboli

    International Nuclear Information System (INIS)

    Ranji Amjad, Mina; Abbasi, Mehrshad; Farzanehfar, Saeed

    2015-01-01

    A 22-year-old woman presented with acute left-sided pleuritic chest pain and dyspnea 6 days after surgery for revision of the stenotic central aortopulmonary shunt. She had a history of tetralogy of Fallot (TOF), pulmonary valve stenosis, ventricular septal defect and major aortopulmonary collateral artery. Her Waterston shunt was placed when she was 5 years old and stented and re-dilated after stenosis. Acute pulmonary thromboemboli (PTE) was suspected and pulmonary perfusion scan was performed with 4 mCi 99m Technetium labeled macroaggregated albumin. The left lung was globally hypoperfused with evident uptake in the brain, renal parenchyma and thyroid. SPECT images revealed a segmental wedge-shaped peripheral defect in the posterior segment of the left upper lobe. The scan was interpreted as acute/chronic PTE or vascular abnormality. CT angiography excluded PTE; nevertheless the patient was treated with a therapeutic dose of heparin changed to warfarin and was discharged with improvement of the symptoms. Pulmonary artery angiography was not performed

  10. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  11. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  12. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  13. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  14. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  15. Transcatheter Aortic Valve Implantation and Morbidity and Mortality-Related Factors: a 5-Year Experience in Brazil

    Directory of Open Access Journals (Sweden)

    André Luiz Silveira Souza

    2016-01-01

    Full Text Available Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87 underwent heart valve implantation; of these, 49% were women, 131 (96.3% had aortic stenosis, one (0.7% had aortic regurgitation and four (2.9% had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%. The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%. The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003 and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036 were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013 and blood transfusion (relative risk of 8.3; p = 0.0009 were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.

  16. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  17. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  18. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  19. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  20. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  1. Cardiac rehabilitation increases physical capacity but not mental health after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, Kirstine L.; Berg, Selina K.; Rasmussen, Trine B.

    2016-01-01

    Objective: The evidence for cardiac rehabilitation after valve surgery remains sparse. Current recommendations are therefore based on patients with ischaemic heart disease. The aim of this randomised clinical trial was to assess the effects of cardiac rehabilitation versus usual care after heart......-educational consultations (intervention) versus usual care without structured physical exercise or psycho-educational consultations (control). Primary outcome was physical capacity measured by VO2 peak and secondary outcome was self-reported mental health measured by Short Form-36. Results: 76% were men, mean age 62 years......, with aortic (62%), mitral (36%) or tricuspid/pulmonary valve surgery (2%). Cardiac rehabilitation compared with control had a beneficial effect on VO2 peak at 4 months (24.8 mL/kg/min vs 22.5 mL/kg/min, p=0.045) but did not affect Short Form-36 Mental Component Scale at 6 months (53.7 vs 55.2 points, p=0...

  2. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  3. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  4. Short-course thrombolysis as the first line of therapy for cardiac valve thrombosis.

    Science.gov (United States)

    Manteiga, R; Carlos Souto, J; Altès, A; Mateo, J; Arís, A; Dominguez, J M; Borrás, X; Carreras, F; Fontcuberta, J

    1998-04-01

    To retrospectively evaluate the clinical and echocardiographic criteria of thrombolytic therapy for mechanical heart valve thrombosis. Nineteen consecutive patients with 22 instances of prosthetic heart valve thrombosis (14 mitral, 2 aortic, 3 tricuspid, and 3 pulmonary) were treated with short-course thrombolytic therapy as first option of treatment in absence of contraindications. The thrombolytic therapy protocol consisted of streptokinase (1,500,000 IU in 90 minutes) (n = 18) in one (n = 7) or two (n = 11) cycles or recombinant tissue-type plasminogen activator (100 mg in 90 minutes) (n = 4). Overall success was seen in 82%, immediate complete success in 59%, and partial success in 23%. Six patients without total response to thrombolytic therapy underwent surgery, and pannus was observed in 83%. Six patients showed complications: allergy, stroke, transient ischemic attack, coronary embolism, minor bleeding, and one death. At diagnosis, 10 patients evidenced atrial thrombus by transesophageal echocardiography, 3 of whom experienced peripheral embolism during thrombolysis. Four episodes of rethrombosis were observed (16%). The survivorship was 84% with a mean follow-up of 42.6 months. A short-course of thrombolytic therapy may be considered first-line therapy for prosthetic heart valve thrombosis. The risk of peripheral embolism may be evaluated for the presence of atrial thrombus by transesophageal echocardiography at diagnosis.

  5. Prenatal Visualization of the Pulmonary and Aortic Valves and Leaflets Is Feasible Using 4-Dimensional Sonography

    NARCIS (Netherlands)

    Adriaanse, B.M.; Uittenbogaard, L.B.; Tromp, C.H.; Heymans, M.W.; Vugt, J.M.G. van; Haak, M.C.

    2016-01-01

    OBJECTIVES: The purpose of this study was to determine whether the morphologic characteristics and area of the semilunar valves in healthy fetuses and fetuses with cardiac defects can be visualized by using spatiotemporal image correlation (STIC). METHODS: Spatiotemporal image correlation volumes

  6. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  7. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  8. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  9. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  10. Effects of valve timing, valve lift and exhaust backpressure on performance and gas exchanging of a two-stroke GDI engine with overhead valves

    International Nuclear Information System (INIS)

    Dalla Nora, Macklini; Lanzanova, Thompson Diórdinis Metzka; Zhao, Hua

    2016-01-01

    Highlights: • Two-stroke operation was achieved in a four-valve direct injection gasoline engine. • Shorter valve opening durations improved torque at lower engine speeds. • The longer the valve opening duration, the lower was the air trapping efficiency. • Higher exhaust backpressure and lower valve lift reduced the compressor work. - Abstract: The current demand for fuel efficient and lightweight powertrains, particularly for application in downsized and hybrid electric vehicles, has renewed the interest in two-stroke engines. In this framework, an overhead four-valve spark-ignition gasoline engine was modified to run in the two-stroke cycle. The scavenging process took place during a long valve overlap period around bottom dead centre at each crankshaft revolution. Boosted intake air was externally supplied at a constant pressure and gasoline was directly injected into the cylinder after valve closure. Intake and exhaust valve timings and lifts were independently varied through an electrohydraulic valve train, so their effects on engine performance and gas exchanging were investigated at 800 rpm and 2000 rpm. Different exhaust backpressures were also evaluated by means of exhaust throttling. Air trapping efficiency, charging efficiency and scavenge ratio were calculated based on air and fuel flow rates, and exhaust oxygen concentration at fuel rich conditions. The results indicated that longer intake and exhaust valve opening durations increased the charge purity and hence torque at higher engine speeds. At lower speeds, although, shorter valve opening durations increased air trapping efficiency and reduced the estimated supercharger power consumption due to lower air short-circuiting. A strong correlation was found between torque and charging efficiency, while air trapping efficiency was more associated to exhaust valve opening duration. The application of exhaust backpressure, as well as lower intake/exhaust valve lifts, made it possible to increase

  11. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  12. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    Science.gov (United States)

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  13. Hemodynamic, pulmonary vascular, and myocardial abnormalities secondary to pharmacologic constriction of the fetal ductus arteriosus. A possible mechanism for persistent pulmonary hypertension and transient tricuspid insufficiency in the newborn infant.

    Science.gov (United States)

    Levin, D L; Mills, L J; Weinberg, A G

    1979-08-01

    The prostaglandin synthetase inhibitor indomethacin was given orally or intravenously to pregnant ewes. This resulted in a significant rise in the fetal pulmonary-to-systemic arterial mean blood pressure difference across the ductus arteriosus, presumably secondary to constriction of the ductus arteriosus. In five experiments the pressure difference could be promptly but temporarily reversed by the administration of prostaglandin E1 (PGE1) into the fetal inferior vena cava. Fetal lungs from study and control animals were fixed by perfusion at measured pulmonary arterial mean blood pressure, and fifth-generation resistance vessels were studied. The medial width/external diameter ratio was significantly increased in the study vs the control lungs due to increased smooth muscle and decreased external diameter. In addition, study fetuses had acute degenerative myocardial changes in the tricuspid valve papillary muscles, the right ventricular free wall and the interventricular septum. Similar changes were not seen in control fetuses. Indomethacin administration during pregnancy causes constriction of the fetal ductus arteriosus, fetal pulmonary arterial hypertension, and right ventricular damage. If severe, this may cause rapid fetal death. If less severe, in the newborn infant, this mechanism may be one cause of persistent pulmonary hypertension due to vasoconstriction and increased pulmonary arterial smooth muscle and/or tricuspid insufficiency due to papillary muscle infarction.

  14. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  15. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  16. Do pulmonary artery catheters cause or increase tricuspid or pulmonic valvular regurgitation?

    Science.gov (United States)

    Sherman, S V; Wall, M H; Kennedy, D J; Brooker, R F; Butterworth, J

    2001-05-01

    There are few quantitative data on the extent or mechanism of pulmonary artery catheter (PAC)-induced valvular dysfunction. We hypothesized that PACs cause or worsen tricuspid and pulmonic valvular regurgitation, and tested this hypothesis by using transesophageal echocardiography. In 54 anesthetized adult patients, we measured color Doppler jet areas of tricuspid regurgitation (TR) in two planes (midesophageal [ME] 4-chamber and right ventricular inflow-outflow views) and pulmonic insufficiency (PI) in one plane (ME aortic valve long-axis view), both before and after we advanced a PAC into the pulmonary artery. Regurgitant jet areas and hemodynamic measurements were compared by using paired t-test. There were no significant changes in blood pressure or heart rate after passage of the PAC. After PAC placement, the mean PI jet area was not significantly increased. The mean TR jet area increased significantly in the right ventricular inflow-outflow view (+0.37 +/- 0.11 cm(2)) (P = 0.0014), but did not increase at the ME 4-chamber view. Seventeen percent of patients had an increase in TR jet area > or =1 cm(2); 8% of patients had an increase in PI jet area >/=1 cm(2). In patients without pulmonic or tricuspid valvular pathology, placement of a pulmonary artery catheter (PAC) worsened tricuspid regurgitation, which is consistently visualized in the right ventricular inflow-outflow view, and often not seen in the midesophageal 4-chamber view. This is consistent with malcoaptation of the anterior and posterior leaflets. PAC-induced pulmonic insufficiency was rarely detected in the midesophageal aortic valve long-axis view. We conclude that a PAC is very unlikely to be the sole cause of severe tricuspid regurgitation or pulmonic insufficiency.

  17. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  18. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  19. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  20. Bilateral branch pulmonary artery stenosis and Mitral valve prolapse in a patient with Noonan syndrome: A case report

    Directory of Open Access Journals (Sweden)

    Meenakshi Kadiyala

    2014-01-01

    Full Text Available Rasopathy syndromes are a class of phenotypically similar, but genetically distinct multiple anomaly syndromes caused by germ line mutations in genes that encode protein components of the Ras/mitogen activated protein kinase (MAPK pathway. Noonan syndrome, cardiofaciocutaneous syndrome and Costello syndrome are part of this group of developmental syndromes and have similar cardiac abnormalities. A 19-year-old male presented with complaints of exertional breathlessness class I for 6 months. Clinical examination revealed characteristic facial features, skeletal abnormalities, growth and neurocognitive problems reported in patients with Noonan syndrome. There was evidence of severe pulmonary hypertension. Trans-thoracic echocardiography revealed right atrial and right ventricular enlargement, severe pulmonary hypertension, no intra cardiac shunt, prolapse of anterior mitral leaflet with mild mitral regurgitation. CT pulmonary angiogram revealed bilateral branch pulmonary artery stenosis. A final diagnosis of Noonan syndrome was made.

  1. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  2. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  3. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  4. Surgical Treatment of Posterior Mitral Valve Prolapse: Towards 100% Repair.

    Science.gov (United States)

    Correia, Pedro M; Coutinho, Gonçalo F; Branco, Carlos; Garcia, Ana; Antunes, Manuel J

    2015-11-01

    The study aim was to evaluate the immediate and long-term results of surgical treatment of isolated posterior mitral valve leaflet prolapse (PLP), focusing on survival and freedom from recurrent mitral regurgitation (MR). Between January 1998 and December 2012, a total of 492 consecutive patients (375 males, 117 females; mean age 61.8 ± 12.1 years; range: 13-86 years) with isolated PLP [304 (61.8%) with myxomatous degeneration; 188 (38.2%) with fibroelastic deficiency] were treated at the authors' institution. Of these patients, 202 (41.1%) were in NYHA class III-IV, and atrial fibrillation was present in 104 (21.1%). Mitral valve repair was achieved in 484 patients (98.4%), resection was performed in 419 (85.2%), and prosthetic ring annuloplasty was used in 436 (88.6%). Concomitant procedures were performed in 153 patients (31.1%), including tricuspid valve repair in 50 (10.2%), aortic valve surgery in 34 (6.9%), and coronary artery bypass grafting (CABG) in 64 (13%). The hospital mortality rate was 0.2%, and the mean follow up was 7.1 ± 3.9 years. There were 71 late deaths (14.4%), and overall survival at five, 10 and 15 years was 91.7 ± 1.3%, 82.1 ± 2.3% and 64.7 ± 6.1%, respectively. There was no significant difference in long-term survival compared with the age- and gender-matched general population (p = 0.146). Multivariate Cox-proportional hazard analysis showed older age (HR 1.03 per annum), left ventricular dysfunction (HR 2.44), atrial fibrillation (HR 1.96), left ventricular end-diastolic dimension (HR 1.05 per mm) and non-use of prosthetic ring (HR 3.03) as significant predictors of late mortality. Recurrence of moderate or severe MR occurred in 31 patients, six of whom underwent mitral valve reoperation. Predictors of late recurrence of MR were fibroelastic deficiency (HR 2.38), mitral calcification (HR 5.26), posterior leaflet plication (HR 3.58), absence of complete ring annuloplasty (HR 3.84) and systolic pulmonary artery pressure at discharge

  5. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    Science.gov (United States)

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of 1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency

  6. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  7. Ross Versus Non-Ross Aortic Valve Replacement in Children: A 22-Year Single Institution Comparison of Outcomes.

    Science.gov (United States)

    Brown, John W; Patel, Parth M; Ivy Lin, Jiuann-Huey; Habib, Asma S; Rodefeld, Mark D; Turrentine, Mark W

    2016-05-01

    The Ross aortic valve replacement (AVR) has been the AVR of choice for children at our center since 1993. Absence or inadequate quality of the pulmonary valve or, less commonly, family or surgeon preference caused us to select an alternative AVR prosthesis for some children. This review compares the outcomes of 42 children who received a non-Ross AVR with 115 children undergoing Ross root replacement at our institution during the most recent 22 years. A retrospective chart review of the 42 pediatric non-Ross AVRs was compared with 115 Ross AVRs. The mean age at AVR was 11.0 ± 6.5 years (range, 1 month to 18 years) for the non-Ross and 11.4 ± 5.5 years (range, 6 weeks to 18 years) for the Ross groups. Follow-up was 7.8 ± 6.2 years for the Ross group and 8.7 ± 6.5 years for the non-Ross group. The Ross AVR technique was modified in 2000; these modifications were applied to 72 patients (63%) of the total Ross AVR group. All-cause early and late mortality of the non-Ross AVR group was 17% compared with 4% for the Ross cohort (p = 0.017). The actuarial survival rate at 20 years for the non-Ross AVR group was 81% compared with 94% for the Ross group (p = 0.018). Reintervention rate was 29% (12/38) in the non-Ross group and 28% (32/115) in the entire Ross group (60% [26/43] before 2000, and 8% [6/72] after 2000). Thromboemboli, bleeding, and endocarditis occurred in 2.4%, 1.4%, and 10% in the non-Ross group compared with 0.9%, 2.6%, and 1.7% in the Ross AVR group (p = 0.46, 0.01, and 0.02), respectively. Patients in the non-Ross group had a significantly higher recurrent or persistent aortic valve gradient (>20 mm Hg) than did patients in the Ross group at most recent follow-up (p Ross AVR than with other types of AVR prostheses. The Ross AVR remains the treatment of choice for children who have an adequate pulmonary valve. Reoperation for Ross root dilatation, regurgitation, or both (only 6% since our modifications in 2000) has markedly reduced the main drawbacks

  8. Use of Dobutamine Stress Echocardiography for Periprocedural Evaluation of a Case of Critical Valvular Pulmonary Stenosis with Delayed Presentation.

    Science.gov (United States)

    Barik, Ramachandra; Akula, Siva Prasad; Damera, Sheshagiri Rao

    2016-01-01

    We report a case illustrating a 39-year-old man with delayed presentation of severe pulmonary valve (PV) stenosis, clinical evidence of congestive right heart failure in the form of enlarged liver, raised jugular venous pressure, and anasarca without cyanosis. Echocardiography (echo) was used both for diagnosis and monitoring this patient as main tool. The contractile reserve of the right ventricle (RV) was evaluated by infusion of dobutamine and diuretic for 4 days before pulmonary balloon valvotomy. Both the tricuspid annular peak systolic excursion and diastolic (diastolic anterograde flow through PV) function of RV improved after percutaneous balloon pulmonary valvotomy. These improvements were clinically apparent by complete resolution of anasarca, pericardial effusion, and normalization albumin-globulin ratio. The periprocedural echo findings were quite unique in this illustration.

  9. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  10. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  11. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  12. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  13. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  14. VALVULAR BRONCHIAL BLOCKING IN TREATMENT OF RELAPSING SPONTANEOUS PHEUMOTHORAX IN THE PATIENT WITH PARASEPTAL PULMONARY EMPHYSEMA

    Directory of Open Access Journals (Sweden)

    O. V. Lovacheva

    2014-01-01

    Full Text Available Spontaneous pneumothorax was treated by placing two endobronchial valves during rigid bronchoscopy under anesthesia in a patient with severe end-stage chronic obstructive pulmonary disease (an emphysematous phenotype and overall paraseptal emphysema in the presence of grade III respiratory failure, with complicated spontaneous pneumothorax recurring manifold even after surgical treatment for spontaneous pneumothorax. This gave rise to the expansion of the lung that had collapsed within 18 months, to healing of bronchopleural fistula, and to return to normal life.The duration of a follow-up was 1 year with the valves being present in the bronchi and another year after their removal; there was no recurrence of spontaneous pneumothorax. Examination of respiratory function established significant positive changes (forced expiratory volume, vital capacity, and forced vital capacity after one year, then after removal of endobronchial valves. There were more significant positive changes in blood gas composition: normalization of blood oxygen saturation was achieved. 

  15. Effect of ventricular size and function on exercise performance and the electrocardiogram in repaired tetralogy of Fallot with pure pulmonary regurgitation

    International Nuclear Information System (INIS)

    Menon, Shaji C; Kaza, Aditya K; Puchalski, Michael D

    2012-01-01

    In repaired tetralogy of Fallot (TOF), exercise test parameters like peak oxygen uptake and ventilatory efficiency predict mortality. Studies have also suggested cardiac magnetic resonance (CMR)-derived right ventricular (RV) size threshold values for pulmonary valve replacement in repaired TOF. However, effects of proposed RV size on exercise capacity and morbidity are not known. The relationship between CMR-derived ventricular size, function, and pulmonary regurgitation (PR) and NYHA class, exercise performance, and electrocardiogram (ECG) was studied in patients of repaired TOF with pure PR in a retrospective review of records. 46 patients (22 females), mean age 14 years (8–30.8), were studied. There was no relationship between CMR-derived ventricular size, function, or PR and exercise test parameters, or NYHA class. RV end systolic and end diastolic volume correlated positively with the degree of PR. QRS duration on ECG correlated positively with RV end-diastolic volume (P < 0.01, r 2 = 0.34) and PR (P < 0.01, r 2 = 0.52). In repaired TOF and pure PR, there is no correlation between ventricular size or function and exercise performance. RV size increases with increasing PR. Timing of pulmonary valve replacement in TOF with pure PR needs further prospective evaluation for its effect on morbidity and mortality

  16. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    Science.gov (United States)

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  17. New engineering treatment of bovine pericardium confers outstanding resistance to calcification in mitral and pulmonary implantations in a juvenile sheep model.

    Science.gov (United States)

    Brizard, Christian P; Brink, Johann; Horton, Steven B; Edwards, Glenn Anthony; Galati, John C; Neethling, William M L

    2014-12-01

    To conduct a test of noninferiority for CardioCel (Admedus, Brisbane, Australia), a chemically engineered bovine pericardium over autologous pericardium treated intraoperatively with glutaraldehyde in a chronic juvenile sheep model of pulmonary valve (PV) and mitral valve (MV) reconstruction. We replaced the posterior leaflet of the MV and of 1 PV cusp with patches in ewes aged 10 months. There were 2 groups: CardioCel (n = 6) and control (n = 4). All valves were competent. Echocardiography was performed before euthanasia. The collected data were function, macroscopy, histology, and calcium contents. The primary end points were thickening and calcium content. All animals survived until sacrifice after 7 months. The valves had normal echo. The macroscopic aspect of the valves was excellent. Examination of the slides for both groups revealed a continuous endothelium on both sides of the patch and a layer of new collagen developed on both sides between patch and endothelium and interstitial cells and smooth muscle cell in these layers. The patch had not thickened but the 2 layers of new collagen for the PV showed a median thickening of 37% in the CardioCel group and 111% in the control group (P = .01), and for the MV a thickening of 108% and 251%, respectively, was seen (P = .01). The median calcium content in the PV was 0.24 μg/mg (range, 0.19-0.30) in the CardioCel group versus 0.34 μg/mg (range, 0.24-0.62) in controls (P = .20). In the MV it was 0.46 μg/mg (range, 0.30-1.0) in the CardioCel group and 0.47 μg/mg (range, 0.29-1.9) in controls (P = 1.0). In this growing lamb model the CardioCel patch allowed accurate valve repair at both systemic and pulmonary pressure. The mechanical properties of CardioCel after 7 months were preserved with a more controlled healing than the treated autologous pericardium and without calcification. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  19. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  20. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  1. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  2. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  3. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  4. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  5. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  6. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  7. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  8. Thermally induced pressure locking of gate valves: A survey of valve bonnet pressurization rates

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Moore, W.E.

    1996-01-01

    Closed, water filled gate valves run the risk of becoming pressurized due to heat input from the environment or from adjacent connected piping. Thermal pressurization of gate valve bonnets may lead to the valves failing to open on demand and can even induce structural failure of valves. This paper presents an analytical prediction of the pressurization rate of a closed pressure vessel subject to uniform heating which may be considered as an upper bound to the pressurization rate that may occur in the field. Then actual valve experiences described in the literature are reviewed to determine the expected pressurization rate in existing hardware designs. A statistical approach is applied to reconcile the differing pressurization rates reported in the literature and determine a rate that can be applied in valve evaluations. The limitations of the reconciled rate are discussed

  9. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  10. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  11. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    Science.gov (United States)

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  12. Managing the right ventricular outflow tract for pulmonary regurgitation after tetralogy of Fallot repair

    Science.gov (United States)

    Hauser, Michael; Eicken, Andreas; Kuehn, Andreas; Hess, John; Fratz, Sohrab; Ewert, Peter; Kaemmerer, Harald

    2013-01-01

    The long-term outcome of patients with tetralogy of Fallot (TOF) with reconstruction of the right ventricular (RV) outflow tract is often complicated by the sequelae of severe pulmonary regurgitation. Progressive enlargement of the right ventricle, biventricular dysfunction and arrhythmia are apparent in more than 50% of the patients in the fourth decade of life. Pathophysiologic implications, clinical assessment and diagnostic modalities are discussed, whereas CMR imaging seems to be the procedure of choice. Therapeutical options for rereconstruction of the RV outflow tract are mentioned, surgical and interventional procedures are explained in detail. The optimal timing of reoperation for significant pulmonary regurgitation after TOF repair is still a matter of controversy given the limited runtime of the lately implanted prostheses and the risk of further reoperation. Early surgery is recommended in these patients before symptoms develop, or RV function has declined. Today we believe that waiting for the patient to become symptomatic is too late. All in all, pulmonary valve replacement is at least indicated in patients developing symptoms due to severe pulmonary regurgitation, particularly if associated with substantial or progressive RV dilatation, tricuspid regurgitation and/or supraventricular or ventricular arrhythmias. PMID:27326099

  13. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  14. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  15. Tricuspid valve dysplasia: A retrospective study of clinical features and outcome in dogs in the UK

    Directory of Open Access Journals (Sweden)

    Xavier Navarro-Cubas

    2017-12-01

    Full Text Available The objective of this study was to determine the demographic, clinical and survival characteristics and to identify risk factors for mortality due to tricuspid valve dysplasia in UK dogs. Records of client-owned dogs diagnosed with tricuspid valve dysplasia at a referral centre were retrospectively reviewed. Only dogs diagnosed with tricuspid valve dysplasia based on the presence of a right-sided heart murmur identified prior to one year of age, and confirmed with Doppler echocardiography, were included. Dogs with concomitant cardiac diseases, pulmonary hypertension and/or trivial tricuspid regurgitation were excluded. Analysed data included signalment, reason for presentation, clinical signs, electrocardiographic and echocardiographic features, survival status and cause of death. Survival times and risk factors for mortality were evaluated using Kaplan-Meier curves and Cox regression. Eighteen dogs met inclusion criteria. Border collies were over-represented (p= 0.014. Dogs were most frequently referred for investigation of heart murmur. The most common arrhythmia was atrial fibrillation (n=3. Median survival time from diagnosis of tricuspid valve dysplasia was 2775 days (range 1-3696 days; 95% CI 1542.41-4007.59 and from onset of right-sided congestive heart failure was 181 days (range 1-2130 days; 95% CI 0-455.59. Syncope was the sole risk factor for cardiac death. In this population of UK dogs, tricuspid valve dysplasia was uncommon but, when severe, frequently led to right-sided congestive heart failure. Prognosis was favourable for mild and moderate tricuspid dysplasia. Survival time was reduced with right-sided congestive heart failure but varied widely. Risk of cardiac death was significantly increased if syncope had occurred.

  16. The prognosis of posterior urethral valves, associated to vesicoureteral reflux in children.

    Science.gov (United States)

    Masca, Aurelia; Indrei, L L; Brânzaniuc, Klara

    2011-01-01

    Posterior urethral valves represent a congenital barrier at the level of the posterior urethra, which opposes miction. They are located near the prostatic urethra, originating at the verumontanum level, affecting male patients. The ureters are inconstantly dilated; vesicoureteral reflux is met in 2/3 of the cases. The reflux can be secondary to the sub-bladder barrier, but it can also be considered primitive, determined by the intra bladder ectopy of the ureter. The presence of the reflux is interpreted as a severe associated factor. Semiology is rather unusual, positive diagnosis is based on early discovery or antenatally of the impairment, by fetal echography starting from the 28th week of pregnancy, postnatal echography followed by miction cystography, retrograde urethrography and creatinine dosage complete the diagnosis. The treatment is surgical: endoscopic ablation of the valves (in the absence of renal failure), percutaneous pyelostomy, high lateral ureterostomy, and in severe cases vesicostomy and renal transplant. Prognosis depends on how early the impairment is detected, on the degree of pulmonary hypoplasia, on the presence of the vesicoureteral reflux and the possibility of recovering renal function; 1/3 of the newborns develop in time Chronic Renal Failure which requires renal transplant. The studied group comprised male children diagnosed with vesicoureteral reflux their ages ranking between 0 -18 years, admitted to the Pediatric Clinic, Tg. Mures during the last 10 years and children diagnosed and operated with posterior urethra valves at the Surgical Clinic of the "M. S. Curie" Hospital, Bucharest during the last 20 years. Our results show that out of the total number of studied children 25 presented posterior urethra valves and 9 children presented vesicoureteral reflux. We can conclude that the presence of the vesicoureteral reflux is an unfavorable prognosis regarding the degree of renal failure.

  17. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  18. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  19. Steroid therapy and conduction disturbances after transcatheter aortic valve implantation.

    Science.gov (United States)

    Havakuk, Ofer; Konigstein, Maayan; Ben Assa, Eyal; Arbel, Yaron; Abramowitz, Yigal; Halkin, Amir; Bazan, Samuel; Shmilovich, Haim; Keren, Gad; Finkelstein, Ariel; Banai, Shmuel

    2016-10-01

    Direct mechanical compression of the frame struts on the adjacent bundle branch with local inflammatory reaction might cause conduction system disturbances and need for pacemaker implantation following transcatheter aortic valve implantation (TAVI). We assessed the impact of preprocedural anti-inflammatory steroid therapy on the occurrence of conduction disturbances following TAVI. From a cohort of 324 patients who underwent transfemoral TAVI, 39 (12%) were pretreated with steroids because of iodine allergy (n=29) or active obstructive pulmonary disease (n=10). We compared the rate of occurrence of new conduction disturbances and pacemaker implantation between TAVI patients with (n=39) and without (n=285) steroid treatment, using Cox logistic regression estimates and proportional hazards models. The overall occurrence of new conduction defects and the need for new pacemaker implantation were similar among steroid and non-steroid-treated patients (38.4% vs 37.5% and 25.6% vs 25.3%, respectively). New conduction disturbances were more prevalent in patients treated with CoreValve prosthesis, low implantation, and smaller aortic annulus diameter (P<.001, P<.001, and P=.006, respectively). Thirty-day mortality and complication rates were similar between the groups. Although safe, steroid treatment prior to TAVI failed to reduce the incidence of new conduction defects and the need for pacemaker implantation. © 2016 John Wiley & Sons Ltd.

  20. Multiresistant-MRSA tricuspid valve infective endocarditis with ancient osteomyelitis locus

    Directory of Open Access Journals (Sweden)

    Gambarati Gianpaolo

    2006-07-01

    Full Text Available Abstract Background Methicillin-resistant S. aureus (MRSA with low susceptibility to glycopeptides is uncommon. Case presentation The case of a 50-year-old non-drug addict patient presenting with tricuspid valve infective endocarditis (IE by MRSA resistant to vancomycin and linezolid is presented. There was response only to quinupristin/dalfopristin. He had a motorcycling accident four years before undergoing right above-the-knee amputation and orthopaedic fixation of the left limb. There were multiple episodes of left MRSA-osteomyelitis controlled after surgery and vancomycin therapy. MRSA isolated from the blood at the time of IE presented with the same profile than the isolated four years earlier. Sequential treatment with teicoplanin-cotrimoxazole and Linezolid associated to vancomycin – rifampicin – cotrimoxazole had no improvement. Infection was controlled after 28 days of therapy with quinupristin/dalfopristin. Conclusion The literature presents only a few cases of MRSA IE not susceptible to glycopeptides in not drug addicted patients. This case shows the comparison of a highly-resistant MRSA after previous S. aureus osteomyelitis treated with glycopeptides. This is the first description of successful treatment of resistant-MRSA IE of the tricuspid valve complicated by multiple pulmonary septic infarction with quinupristin/dalfopristin

  1. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  2. Cardiogenic Pulmonary Edema in a Dog Following Initiation of Therapy for Concurrent Hypoadrenocorticism and Hypothyroidism.

    Science.gov (United States)

    Paik, Jooyae; Kang, Ji-Houn; Chang, Dongwoo; Yang, Mhan-Pyo

    A 5 yr old intact female cocker spaniel dog weighing 7.8 kg was referred with anorexia, vomiting, and depression. At referral, the dog was diagnosed initially with typical hypoadrenocorticism, and 2 d later, concurrent primary hypothyroidism was detected. Hormonal replacement therapies, including fludrocortisone, prednisolone, and levothyroxine, were initiated, but a few days later the dog became abruptly tachypneic, and thoracic radiographs indicated the development of pulmonary edema. Echocardiography showed that there were abnormalities indicating impaired left ventricular function, although the heart valves were normal. Following treatment with pimobendan and furosemide, the pulmonary edema resolved. The dog had no recurrence of the clinical signs after 10 mo of follow-up, despite being off all cardiac medications; consequently, the cardiac failure was transient or reversible in this dog. The case report describes the stepwise diagnosis and successful treatment of cardiogenic pulmonary edema after initiation of hormonal replacement therapy for concurrent hypoadrenocorticism and hypothyroidism in a dog.

  3. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  5. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  6. A case report of partial anomalous pulmonary venous connection and its surgical repair

    Directory of Open Access Journals (Sweden)

    Mandegar MH

    1994-05-01

    Full Text Available This article aim is to introduce a case of PAPVC (partial anomalous pulmonary venous connection. The patient was a 25-year-old women who had dyspnea and palpitation. She expressed no special disease, no past medical history, and no drug usage, but her brother and her aunt had the above-mentioned history. In the physical examination, lungs were clear and the heart had S2 splitting, and there was a systolic murmur in the pulmonary area. Her liver could be palpitated two centimeters below the costal edge, but she didn't have any hepatomegaly. In cardiac catheterism, she had PAPVC, atrial septal defect (ASD, and mitral valve prolapse (MVP. The patient underwent operation had left pulmonary vein was separated from the superior vena cava and anastomosed to the left atrial auricle. By means of the pericardial patch, the left atrium became enlarged and ASD was closed. She was in a good condition after surgery and left the hospital without any complication with a good condition and recovery and had no problem any longer.

  7. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  8. The Voice of the Heart: Vowel-Like Sound in Pulmonary Artery Hypertension

    Directory of Open Access Journals (Sweden)

    Mohamed Elgendi

    2018-04-01

    Full Text Available Increased blood pressure in the pulmonary artery is referred to as pulmonary hypertension and often is linked to loud pulmonic valve closures. For the purpose of this paper, it was hypothesized that pulmonary circulation vibrations will create sounds similar to sounds created by vocal cords during speech and that subjects with pulmonary artery hypertension (PAH could have unique sound signatures across four auscultatory sites. Using a digital stethoscope, heart sounds were recorded at the cardiac apex, 2nd left intercostal space (2LICS, 2nd right intercostal space (2RICS, and 4th left intercostal space (4LICS undergoing simultaneous cardiac catheterization. From the collected heart sounds, relative power of the frequency band, energy of the sinusoid formants, and entropy were extracted. PAH subjects were differentiated by applying the linear discriminant analysis with leave-one-out cross-validation. The entropy of the first sinusoid formant decreased significantly in subjects with a mean pulmonary artery pressure (mPAp ≥ 25 mmHg versus subjects with a mPAp < 25 mmHg with a sensitivity of 84% and specificity of 88.57%, within a 10-s optimized window length for heart sounds recorded at the 2LICS. First sinusoid formant entropy reduction of heart sounds in PAH subjects suggests the existence of a vowel-like pattern. Pattern analysis revealed a unique sound signature, which could be used in non-invasive screening tools.

  9. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  10. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  11. Spirolit-2 instrument used to test pulmonary ventilation

    Science.gov (United States)

    Zhuravlev, V. V.

    1985-02-01

    At the present time, the Spirolit-2 automatic analyzer of main respiratory gases, of the Junkalor Dessau firm, is used to examine parameters of gas exchange, levels of energy expended by man and animals with different degrees of activity. However, the capabilities of this model of the instrument are limited. A method of determining pulmonary ventilation with use of the Spirolit-2 is described. An additional exhalation valve is built into a valve box to which an anesthesia machine rubber bag is attached. Samples are collected into another bag concurrently with the usual tests on the Spirolit-2 instrument. Four to five minutes are sufficient to obtain stable parameters at relative rest of oxygen uptake, determine carbon dioxide output per minute and collect samples in for analysis of exhaled air. The proposed method can furnish information about the dynamics of development of respiratory function of the lungs at virtually any moment with a constant physical load. For this, there must be spare bags to collect samples. Stage-by-stage data can be obtained analogously as to ventilation volume during a step test while determining maximum oxygen uptake.

  12. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium.

    Science.gov (United States)

    Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T

    2017-04-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  14. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  15. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  16. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  17. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  19. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  20. Griswold Tempered Water Flow Regulator Valves Used as Anti-Siphon Valves

    International Nuclear Information System (INIS)

    MISKA, C.

    2000-01-01

    FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus

  1. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  2. Protein losing enteropathy secondary to a pulmonary artery stent

    Directory of Open Access Journals (Sweden)

    Narayanswami Sreeram

    2012-01-01

    Full Text Available A 2-year-old patient with hypoplastic left heart syndrome presented 6 months following Fontan completion with protein-losing enteropathy (PLE. He had undergone stent implantation in the left pulmonary artery after the Norwood procedure, followed by redilation of the stent prior to Fontan completion. Combined bronchoscopic and catheterization studies during spontaneous breathing confirmed left bronchial stenosis behind the stent, and diastolic systemic ventricular pressure during expiration of 25 mm Hg. We postulate that the stent acts as a valve, against which the patient generates high expiratory pressures, which are reflected in the ventricular diastolic pressure. This may be the cause of PLE.

  3. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  4. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  5. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    Science.gov (United States)

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  6. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  7. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  8. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  10. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  11. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  13. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  14. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  15. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  16. Power loss and right ventricular efficiency in patients after tetralogy of Fallot repair with pulmonary insufficiency: clinical implications.

    Science.gov (United States)

    Fogel, Mark A; Sundareswaran, Kartik S; de Zelicourt, Diane; Dasi, Lakshmi P; Pawlowski, Tom; Rome, Jack; Yoganathan, Ajit P

    2012-06-01

    To quantify right ventricular output power and efficiency and correlate these to ventricular function in patients with repaired tetralogy of Fallot. This might aid in determining the optimal timing for pulmonary valve replacement. We reviewed the cardiac catheterization and magnetic resonance imaging data of 13 patients with tetralogy of Fallot (age, 22 ± 17 years). Using pressure and flow measurements in the main pulmonary artery, cardiac output and regurgitation fraction, right ventricular (RV) power output, loss, and efficiency were calculated. The RV function was evaluated using cardiac magnetic resonance imaging. The RV systolic power was 1.08 ± 0.62 W, with 20.3% ± 8.6% power loss owing to 41% ± 14% pulmonary regurgitation (efficiency, 79.7% ± 8.6%; 0.84 ± 0.73 W), resulting in a net cardiac output of 4.24 ± 1.82 L/min. Power loss correlated significantly with the indexed RV end-diastolic and end-systolic volume (R = 0.78, P = .002 and R = 0.69, P = .009, respectively). The normalized RV power output had a significant negative correlation with RV end-diastolic and end-systolic volumes (both R = -0.87, P = .002 and R = -0.68, P = .023, respectively). A rapid decrease occurred in the RV power capacity with an increasing RV volume, with the curve flattening out at an indexed RV end-diastolic and end-systolic volume threshold of 139 mL/m(2) and 75 mL/m(2), respectively. Significant power loss is present in patients with repaired tetralogy of Fallot and pulmonary regurgitation. A rapid decrease in efficiency occurs with increasing RV volume, suggesting that pulmonary valve replacement should be done before the critical value of 139 mL/m(2) and 75 mL/m(2) for the RV end-diastolic and end-systolic volume, respectively, to preserve RV function. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. Chronic antepartum maternal hyperoxygenation in a case of severe fetal Ebstein's anomaly with circular shunt physiology

    Directory of Open Access Journals (Sweden)

    Alisa Arunamata

    2017-01-01

    Full Text Available Perinatal mortality remains high among fetuses diagnosed with Ebstein's anomaly of the tricuspid valve. The subgroup of patients with pulmonary valve regurgitation is at particularly high risk. In the setting of pulmonary valve regurgitation, early constriction of the ductus arteriosus may be a novel perinatal management strategy to reduce systemic steal resulting from circular shunt physiology. We report the use of chronic antepartum maternal oxygen therapy for constriction of the fetal ductus arteriosus and modulation of fetal pulmonary vascular resistance in a late presentation of Ebstein's anomaly with severe tricuspid valve regurgitation, reversal of flow in the ductus arteriosus, and continuous pulmonary valve regurgitation.

  18. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  19. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  20. Initial experience with percutaneous edge-to-edge transcatheter mitral valve repair in a tertiary medical center in Taiwan

    Directory of Open Access Journals (Sweden)

    Ching-Wei Lee

    2018-04-01

    Full Text Available Background: The transcatheter edge-to-edge mitral valve repair, using MitraClip, has been a safe and effective treatment for severe mitral regurgitation (SMR in the westerners. However, the therapeutic results of the MitralClip in Taiwan remained elucidated. Methods: Patients with symptomatic SMR were evaluated by the heart team. For those with high or prohibitive surgical risks, transcatheter mitral valve repair was performed in hybrid operation room. During procedure, continuous hemodynamic monitoring was conducted. Transthoracic echocardiography (TTE, blood tests, and six-minute walk test (6MWT were performed before and 1-month after surgery. Results: A total of 20 patients (73.4 ± 11.1 years, 85% male with a mean Euroscore II of 13.2 ± 17.7% and a mean STS score of 8.7 ± 9.0% for mortality were enrolled. After a mean procedural time of 239 ± 95 min, an average of 1.8 ± 0.7 clips were used in each procedure. The procedural successful rate was 95% to achieve mild residual mitral regurgitation. Cardiac output was increased from 3.6 ± 0.9 to 4.6 ± 1.4 (p = 0.008 and V-wave of left atrial pressure declined from 24.4 ± 9.8 to 19.3 ± 7.1 (p = 0.030 immediately during the index procedure. There was no peri-procedural death, myocardial infarction, stroke or any events requiring emergent cardiac surgery. All patients experienced significant improvement in heart failure symptoms. The 6-min walk distance increased from 219.6 ± 118.4 m to 279.1 ± 111.6 (p = 0.04 at 1 month. The echocardiogram further showed significant improvements of mitral regurgitation, pulmonary artery systolic pressure, and the left ventricular end-diastolic volume. Conclusion: Trans-catheter edge-to-edge mitral valve repairs are safe and effective in Asians with symptomatic SMR, regarding the improvements of clinical symptoms and exercise capacities. MitraClips is also associated with reverse remodeling of pulmonary hypertension and left

  1. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  2. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  3. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  4. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  5. Acute pulmonary edema due to stress cardiomyopathy in a patient with aortic stenosis: a case report

    OpenAIRE

    Bayer, Monika F

    2009-01-01

    Introduction Stress cardiomyopathy is a condition of chest pain, breathlessness, abnormal heart rhythms and sometimes congestive heart failure or shock precipitated by intense mental or physical stress. Case presentation A 64-year-old male with a known diagnosis of moderate-to-severe aortic stenosis and advised that valve replacement was not urgent, presented with acute pulmonary edema following extraordinary mental distress. The patient was misdiagnosed as having a "massive heart attack" and...

  6. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  7. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  9. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  10. Valve-stem-packing improvement study. Final report

    International Nuclear Information System (INIS)

    Adey, C.W.; Klein, J.J.

    1982-08-01

    By employing questionnaires and face-to-face interviews with valve and valve packing manufacturers, as well as nuclear plant personnel, an understanding of valve stem packing leakage problems from each of the three viewpoints was developed. This information, in-house experience, and available technical literature were used to develop specific recommendations for valve manufacturers, valve packing manufacturers, and nuclear plant valve users. It was generally recommended that each these groups make better use of graphite packing. The questionnaires and interviews indicated that increased usage of graphite packing over the last few years has reduced the incidence of valve packing problems. To confirm this, a survey of Licensee Event Reports (LERs) from 1972 to 1980 was undertaken using the keywords Valve and Packing. A statistical analysis of the LER data confirms that the adoption of graphite packing has significantly reduced valve stem leakage

  11. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  12. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  13. Pulmonary Hypertension and Pulmonary Vasodilators.

    Science.gov (United States)

    Keller, Roberta L

    2016-03-01

    Pulmonary hypertension in the perinatal period can present acutely (persistent pulmonary hypertension of the newborn) or chronically. Clinical and echocardiographic diagnosis of acute pulmonary hypertension is well accepted but there are no broadly validated criteria for echocardiographic diagnosis of pulmonary hypertension later in the clinical course, although there are significant populations of infants with lung disease at risk for this diagnosis. Contributing cardiovascular comorbidities are common in infants with pulmonary hypertension and lung disease. It is not clear who should be treated without confirmation of pulmonary vascular disease by cardiac catheterization, with concurrent evaluation of any contributing cardiovascular comorbidities. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Gate valve and motor-operator research findings

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves)

  15. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  16. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.

    Science.gov (United States)

    Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M

    2001-08-01

    The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.

  17. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  18. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  19. Changing Roots : Remodelling after the Ross Operation

    NARCIS (Netherlands)

    A. Mookhoek (Aart)

    2016-01-01

    textabstractThe Ross operation is a surgical intervention in which a diseased aortic valve is replaced by the pulmonary valve of the same patient. A donor valve replaces the pulmonary valve. In this thesis, several key unanswered clinical questions are explored. Early mortality after the Ross

  20. An analytical investigation on the valve and centrifugal pump speed control with a constant differential pressure across the valve

    International Nuclear Information System (INIS)

    Jung, B. R.; Joo, K. I.; Lee, B. J.; Baek, S. J.; Noh, T. S.

    2003-01-01

    A valve opening and centrifugal pump speed control was investigated analytically in a simple pumping system where the differential pressure across the control valve is maintained constant over the required flow range. The valve control program was derived analytically only as a function of the required flow rate to maintain the constant differential pressure across the valve. The centrifugal pump speed control program was also derived analytically for the required flow rate for the constant differential pressure across the control valve. These derivations theoretically show that the independent control is possible between the valve and pump speed in a system with a constant valve pressure drop. In addition, it was shown that a linear pump speed control is impossible in maintaining the constant valve pressure drop

  1. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  2. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  3. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  4. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  5. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  6. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  7. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  8. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Local and systemic RAGE axis changes in pulmonary hypertension: CTEPH and iPAH.

    Directory of Open Access Journals (Sweden)

    Bernhard Moser

    Full Text Available OBJECTIVE: The molecular determinants of chronic thromboembolic pulmonary hypertension (CTEPH and idiopathic pulmonary arterial hypertension (iPAH remain poorly understood. The receptor for advanced glycation endproducts (RAGE and its ligands: HMGB1 and S100A9 are involved in inflammatory disorders. We sought to investigate the role of the RAGE axis in patients with CTEPH undergoing pulmonary endarterectomy (PEA, iPAH undergoing lung transplantation (LuTX. The high pulmonary vascular resistance in CTEPH/iPAH results in pressure overload of the right ventricle. We compared sRAGE measurements to that of patients with aortic valve stenosis (AVS - pressure overload of the left ventricle. METHODS: We enrolled patients with CTEPH(26, iPAH(15, AVS(15 and volunteers(33. Immunohistochemistry with antibodies to RAGE and HMGB1 was performed on PEA specimens and lung tissues. We employed enzyme-linked immunosorbent assays to determine the concentrations of sRAGE, esRAGE, HMGB1 and S100A9 in serum of volunteers and patients with CTEPH, iPAH, AVS before and after PEA, LuTX and aortic valve replacement (AVR. RESULTS: In endarterectomised tissues from patients with CTEPH RAGE and HMGB1 were identified in myofibroblasts (α-SMA+vimentin+CD34-, recanalizing vessel-like structures of distal myofibrotic tissues and endothelium of neointima. RAGE was differentially expressed in prototypical Heath Edwards lesions in iPAH. We found significantly increased serum concentrations of sRAGE, esRAGE and HMGB1 in CTEPH. In iPAH, sRAGE and esRAGE were significantly higher than in controls. Serum concentrations of sRAGE were significantly elevated in iPAH(p<0.001 and CTEPH(p = 0.001 compared to AVS. Serum sRAGE was significantly higher in iPAH compared to CTEPH(p = 0.042 and significantly reduced in AVS compared to controls(p = 0.001. There were no significant differences in sRAGE serum concentrations before and after surgical therapy for CTEPH, iPAH or AVS. CONCLUSIONS: Our

  10. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  11. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair

    Science.gov (United States)

    Park, Han Ki

    2013-01-01

    Repair of tetralogy of Fallot (TOF) has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS) and free pulmonary regurgitation (PR) at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT) reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR) increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF. PMID:23807889

  12. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair.

    Science.gov (United States)

    Yoo, Byung Won; Park, Han Ki

    2013-06-01

    Repair of tetralogy of Fallot (TOF) has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS) and free pulmonary regurgitation (PR) at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT) reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR) increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF.

  13. Pulmonary stenosis and pulmonary regurgitation: both ends of the spectrum in residual hemodynamic impairment after tetralogy of Fallot repair

    Directory of Open Access Journals (Sweden)

    Byung Won Yoo

    2013-06-01

    Full Text Available Repair of tetralogy of Fallot (TOF has shown excellent outcomes. However it leaves varying degrees of residual hemodynamic impairment, with severe pulmonary stenosis (PS and free pulmonary regurgitation (PR at both ends of the spectrum. Since the 1980s, studies evaluating late outcomes after TOF repair revealed the adverse impacts of residual chronic PR on RV volume and function; thus, a turnaround of operational strategies has occurred from aggressive RV outflow tract (RVOT reconstruction for complete relief of RVOT obstruction to conservative RVOT reconstruction for limiting PR. This transformation has raised the question of how much residual PS after conservative RVOT reconstruction is acceptable. Besides, as pulmonary valve replacement (PVR increases in patients with RV deterioration from residual PR, there is concern regarding when it should be performed. Regarding residual PS, several studies revealed that PS in addition to PR was associated with less PR and a small RV volume. This suggests that PS combined with PR makes RV diastolic property to protect against dilatation through RV hypertrophy and supports conservative RVOT enlargement despite residual PS. Also, several studies have revealed the pre-PVR threshold of RV parameters for the normalization of RV volume and function after PVR, and based on these results, the indications for PVR have been revised. Although there is no established strategy, better understanding of RV mechanics, development of new surgical and interventional techniques, and evidence for the effect of PVR on RV reverse remodeling and its late outcome will aid us to optimize the management of TOF.

  14. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  15. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  16. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  17. Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy.

    Science.gov (United States)

    Yalçin, Fatih; El-Amrousy, Mahmoud; Müderrisoğlu, Haldun; Korkmaz, Mehmet; Flachskampf, Frank; Tuzcu, Murat; Garcia, Mario G; Thomas, James D

    2002-01-01

    Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (pLA pressure were correlated with changes in S/D (r=0.57, pLA pressure-volume relationship were also correlated with changes in S/D (r=0.52, pLA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

  18. Krox20 defines a subpopulation of cardiac neural crest cells contributing to arterial valves and bicuspid aortic valve.

    Science.gov (United States)

    Odelin, Gaëlle; Faure, Emilie; Coulpier, Fanny; Di Bonito, Maria; Bajolle, Fanny; Studer, Michèle; Avierinos, Jean-François; Charnay, Patrick; Topilko, Piotr; Zaffran, Stéphane

    2018-01-03

    Although cardiac neural crest cells are required at early stages of arterial valve development, their contribution during valvular leaflet maturation remains poorly understood. Here, we show in mouse that neural crest cells from pre-otic and post-otic regions make distinct contributions to the arterial valve leaflets. Genetic fate-mapping analysis of Krox20-expressing neural crest cells shows a large contribution to the borders and the interleaflet triangles of the arterial valves. Loss of Krox20 function results in hyperplastic aortic valve and partially penetrant bicuspid aortic valve formation. Similar defects are observed in neural crest Krox20 -deficient embryos. Genetic lineage tracing in Krox20 -/- mutant mice shows that endothelial-derived cells are normal, whereas neural crest-derived cells are abnormally increased in number and misplaced in the valve leaflets. In contrast, genetic ablation of Krox20 -expressing cells is not sufficient to cause an aortic valve defect, suggesting that adjacent cells can compensate this depletion. Our findings demonstrate a crucial role for Krox20 in arterial valve development and reveal that an excess of neural crest cells may be associated with bicuspid aortic valve. © 2018. Published by The Company of Biologists Ltd.

  19. Flow-related Right Ventricular - Pulmonary Arterial Pressure Gradients during Exercise.

    Science.gov (United States)

    Wright, Stephen P; Opotowsky, Alexander R; Buchan, Tayler A; Esfandiari, Sam; Granton, John T; Goodman, Jack M; Mak, Susanna

    2018-06-06

    The assumption of equivalence between right ventricular and pulmonary arterial systolic pressure is fundamental to several assessments of right ventricular or pulmonary vascular hemodynamic function. Our aims were to 1) determine whether systolic pressure gradients develop across the right ventricular outflow tract in healthy adults during exercise, 2) examine the potential correlates of such gradients, and 3) consider the effect of such gradients on calculated indices of right ventricular function. Healthy untrained and endurance-trained adult volunteers were studied using right-heart catheterization at rest and during submaximal cycle ergometry. Right ventricular and pulmonary artery pressures were simultaneously transduced, and cardiac output was determined by thermodilution. Systolic pressures, peak and mean gradients, and indices of chamber, vascular, and valve function were analyzed offline. Summary data are reported as mean ± standard deviation or median [interquartile range]. No significant right ventricular outflow tract gradients were observed at rest (mean gradient = 4 [3-5] mmHg), and calculated effective orifice area was 3.6±1.0 cm2. Right ventricular systolic pressure increases during exercise were greater than that of pulmonary artery systolic pressure. Accordingly, mean gradients developed during light exercise (8 [7-9] mmHg) and increased during moderate exercise (12 [9-14] mmHg, p < 0.001). The magnitude of the mean gradient was linearly related to cardiac output (r2 = 0.70, p < 0.001). In healthy adults without pulmonic stenosis, systolic pressure gradients develop during exercise, and the magnitude is related to blood flow rate.

  20. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    Science.gov (United States)

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Improved corrosion resistance of spin-valve film

    International Nuclear Information System (INIS)

    Tetsukawa, H.; Hommura, H.; Okabe, A.; Soda, Y.

    2007-01-01

    We investigated the corrosion behavior and magnetoresistance of spin-valve film in order to improve the corrosion resistance of the spin-valve head for a tape recording system. The conventional spin-valve head (sub./Ta/NiFe/CoFe/Cu/CoFe/PtMn/Ta) with no diamond-like carbon (DLC) protective layer showed poor corrosion resistance. This is because the CoFe for ferromagnetic layer and Cu for spacer in the spin-valve film exhibited poor corrosion resistance. The corrosion resistance of the CoFe film and Cu film improved with the addition of Ni and Au, respectively. The spin-valve film (sub./Ta/NiFe/CoNiFe/CuAu/CoNiFe/PtMn/Ta) showed higher pitting potential than the conventional spin-valve film by +0.45 V. This presents a significant improvement over the conventional spin-valve film. We also investigated the effect of the composition of ferromagnetic layer and spacer on the magnetoresistance of the spin-valve film. The magnetoresistance of the spin-valve film by substitution of CoNiFe for CoFe in ferromagnetic layer decreased slightly. The magnetoresistance of the spin-valve film decreased as the addition of Au of the spacer increased. The diffusion at CoNiFe/CuAu interface has not been observed in annealing process. The quantitative relation between corrosion resistance and magnetoresistance of spin-valve film, and its ferromagnetic layer and spacer's compositions have been clarified. The output voltage at 50 Oe of the corrosion-resistant spin-valve head with CoNiFe ferromagnetic layer and CuAu spacer was about 50% of that of the conventional spin-valve head

  2. Improved corrosion resistance of spin-valve film

    Energy Technology Data Exchange (ETDEWEB)

    Tetsukawa, H. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)]. E-mail: tetsukaw@arc.sony.co.jp; Hommura, H. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan); Okabe, A. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan); Soda, Y. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)

    2007-06-15

    We investigated the corrosion behavior and magnetoresistance of spin-valve film in order to improve the corrosion resistance of the spin-valve head for a tape recording system. The conventional spin-valve head (sub./Ta/NiFe/CoFe/Cu/CoFe/PtMn/Ta) with no diamond-like carbon (DLC) protective layer showed poor corrosion resistance. This is because the CoFe for ferromagnetic layer and Cu for spacer in the spin-valve film exhibited poor corrosion resistance. The corrosion resistance of the CoFe film and Cu film improved with the addition of Ni and Au, respectively. The spin-valve film (sub./Ta/NiFe/CoNiFe/CuAu/CoNiFe/PtMn/Ta) showed higher pitting potential than the conventional spin-valve film by +0.45 V. This presents a significant improvement over the conventional spin-valve film. We also investigated the effect of the composition of ferromagnetic layer and spacer on the magnetoresistance of the spin-valve film. The magnetoresistance of the spin-valve film by substitution of CoNiFe for CoFe in ferromagnetic layer decreased slightly. The magnetoresistance of the spin-valve film decreased as the addition of Au of the spacer increased. The diffusion at CoNiFe/CuAu interface has not been observed in annealing process. The quantitative relation between corrosion resistance and magnetoresistance of spin-valve film, and its ferromagnetic layer and spacer's compositions have been clarified. The output voltage at 50 Oe of the corrosion-resistant spin-valve head with CoNiFe ferromagnetic layer and CuAu spacer was about 50% of that of the conventional spin-valve head.

  3. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  4. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  5. Long-term follow-up in repaired tetralogy of fallot: can deformation imaging help identify optimal timing of pulmonary valve replacement?

    Science.gov (United States)

    Sabate Rotes, Anna; Bonnichsen, Crystal R; Reece, Chelsea L; Connolly, Heidi M; Burkhart, Harold M; Dearani, Joseph A; Eidem, Benjamin W

    2014-12-01

    Novel echocardiographic techniques based on myocardial deformation have not been extensively evaluated to assess right ventricular (RV) and left ventricular (LV) response after pulmonary valve replacement (PVR) in patients with repaired tetralogy of Fallot. Between 2003 and 2012, 133 patients undergoing first-time PVR after tetralogy of Fallot repair underwent echocardiographic assessment at Mayo Clinic. The last echocardiogram before PVR and 1 year after surgery were retrospectively analyzed with Velocity Vector Imaging. Mean age at PVR was 35.5 ± 16.2 years (54% women). Longitudinal peak systolic strain and strain rate before PVR were low: for the left ventricle, -14.8 ± 3.5% and -0.8 ± 0.2 sec(-1), and for the right ventricle, -16.2 ± 4.1% and -0.9 ± 0.3 sec(-1), respectively. There was no significant change in either parameter after surgery. A close correlation between LV and RV deformational parameters was found before PVR and was maintained after surgery. In the multivariate analysis, patients with better LV and RV peak systolic strain preoperatively were found to have better LV and RV peak systolic strain after surgery (P = .004 and P = .006, respectively). However, patients with the most improvement in deformation were those with worse RV function preoperatively (P = .002). Mean New York Heart Association class at early follow-up improved from 2.2 ± 0.8 to 1.2 ± 0.6 (P tetralogy of Fallot undergoing PVR, and there was no significant change after surgery. However, preoperative systolic deformational parameters were predictive of postoperative ventricular function and New York Heart Association class after PVR and may be helpful to identify optimal timing for surgical intervention in this cohort. Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  6. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  7. Echocardiographic Assessment of Heart Valve Prostheses

    Science.gov (United States)

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  8. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  9. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  10. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  11. An unusual neonatal presentation of anomalous origin of the left coronary artery arising from the pulmonary artery.

    Science.gov (United States)

    Garty, Y; Guri, A; Shinwell, E S; Matitiau, A

    2008-01-01

    We describe a previously unreported neonatal presentation of an anomalous origin of the left coronary artery arising from the pulmonary artery. This is a full-term female infant after normal pregnancy and delivery. The baby was diagnosed at 2 days of age due to weak femoral pulses noted on the routine nursery discharge examination. The cardiac examination revealed weak pulses everywhere and mild tachypnea and tachycardia. An electrocardiogram showed clear signs of ischemia. Echocardiography demonstrated an anomalous origin of the left coronary artery arising from the pulmonary artery with bidirectional blood flow. There was a severely depressed left ventricular function and mild mitral valve regurgitation. At 4 days of age, the infant underwent complete successful surgical repair with reimplantation of the anomalous coronary artery to the aorta. She recovered slowly but well. Fifteen months later she is doing well with no cardiac residua. A neonatal presentation is very unusual due to protective high pulmonary resistance after birth, with gradual decline in pressure and gradual onset of heart failure. This case may be related to an unusually rapid drop in pulmonary vascular resistance causing very early cardiac ischemia. (c) 2007 S. Karger AG, Basel.

  12. All in the family: matrimonial mitral valve clicks.

    Science.gov (United States)

    Desser, K B; Bokhari, S I; Benchimol, A; Romney, D

    1981-05-01

    Mitral valve clicks with or without late systolic murmurs were detected in genetically unrelated marital partners of 5 families. The first family represented 2 successive nonconsanguineous marital unions with 3 generations of mitral valve clicks. The second family included 1 natural and 2 adopted children with clinical and echographic evidence of mitral valve prolapse. The third family was comprised of asymptomatic parents, both with nonejection clicks and mitral valve prolapse, whose daughter presented 3 years previously with syncope, palpitations, and combined mitral and tricuspid valve prolapse. The fourth family had 3 members with auscultatory and ultrasonic manifestations of billowing mitral valve, whereas the fourth member had "silent mitral valve prolapse." The fifth family represented a mother with auscultatory and echographic evidence of mitral valve prolapse; her 14-year-old daughter had both mitral and tricuspid valve prolapse, whereas the son had a bicuspid aortic valve. Both children were products of a prior marriage, and her husband has symptomatic mitral valve prolapse. We conclude that matrimonial mitral valve prolapse probably reflects the purported (6--10%) prevalence of this disorder in the general population. The consequences of such marital union on progeny is currently unclear and warrants future investigation.

  13. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  14. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    Science.gov (United States)

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  15. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    Science.gov (United States)

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  16. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].

    Science.gov (United States)

    Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio

    2015-07-01

    A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.

  17. Safety valve opening and closing operation monitor

    International Nuclear Information System (INIS)

    Kodama, Kunio; Takeshima, Ikuo; Takahashi, Kiyokazu.

    1981-01-01

    Purpose: To enable the detection of the closing of a safety valve when the internal pressure in a BWR type reactor is a value which will close the safety valve, by inputting signals from a pressure detecting device mounted directly at a reactor vessel and a safety valve discharge pressure detecting device to an AND logic circuit. Constitution: A safety valve monitor is formed of a pressure switch mounted at a reactor pressure vessel, a pressure switch mounted at the exhaust pipe of the escape safety valve and a logic circuit and the lide. When the input pressure of the safety valve is raised so that the valve and the pressure switch mounted at the exhaust pipe are operated, an alarm is indicated, and the operation of the pressure switch mounted at a pressure vessel is eliminated. If the safety valve is not reclosed when the vessel pressure is decreased lower than the pressure at which it is to be reclosed after the safety valve is operated, an alarm is generated by the logic circuit since both the pressure switches are operated. (Sekiya, K.)

  18. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve).

    Science.gov (United States)

    Makkar, Raj R; Jilaihawi, Hasan; Chakravarty, Tarun; Fontana, Gregory P; Kapadia, Samir; Babaliaros, Vasilis; Cheng, Wen; Thourani, Vinod H; Bavaria, Joseph; Svensson, Lars; Kodali, Susheel; Shiota, Takahiro; Siegel, Robert; Tuzcu, E Murat; Xu, Ke; Hahn, Rebecca T; Herrmann, Howard C; Reisman, Mark; Whisenant, Brian; Lim, Scott; Beohar, Nirat; Mack, Michael; Teirstein, Paul; Rihal, Charanjit; Douglas, Pamela S; Blackstone, Eugene; Pichard, Augusto; Webb, John G; Leon, Martin B

    2013-07-30

    This study investigated the determinants and outcomes of acute insertion of a second transcatheter prosthetic valve (TV) within the first (TV-in-TV) or transcatheter valve embolization (TVE) after transcatheter aortic valve replacement (TAVR). TAVR failure can occur with both TV-in-TV and TVE as a consequence of TAVR malpositioning. Only case reports and limited series pertaining to these complications have been reported to date. Patients undergoing TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve) randomized trial (cohorts A and B) and accompanying registries were studied. Data were dichotomized for those with and without TV-in-TV or TVE, respectively. From a total of 2,554 consecutive patients, 63 (2.47%) underwent TV-in-TV and 26 (1.01%) TVE. The indication for TV-in-TV was significant aortic regurgitation in most patients, often due not only to malpositioning but also to leaflet dysfunction. Despite similar aortic valve function on follow-up echoes, TV-in-TV was an independent predictor of 1-year cardiovascular mortality (hazard ratio [HR]: 1.86, 95% confidence interval [CI]: 1.03 to 3.38, p = 0.041), with a nonsignificant trend toward greater all-cause mortality (HR: 1.43, 95% CI: 0.88 to 2.33, p = 0.15). Technical and anatomical reasons accounted for most cases of TVE. A multivariable analysis found TVE to be an independent predictor of 1-year mortality (HR: 2.68, 95% CI: 1.34 to 5.36, p = 0.0055) but not cardiovascular mortality (HR: 1.30, 95% CI: 0.48 to 3.52, p = 0.60). Acute TV-in-TV and TVE are serious sequelae of TAVR, often resulting in multiple valve implants. They carry an excess of mortality and are caused by anatomic and technical factors, which may be avoidable with judicious procedural planning. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Performance of balanced bellows safety relief valves

    International Nuclear Information System (INIS)

    Lai, Y.S.

    1992-01-01

    By the nature of its design, the set point and lift of a conventional spring loaded safety relief valve are sensitive to back pressure. One way to reduce the adverse effects of the back pressure on the safety relief valve function is to install a balanced bellows in a safety relief valve. The metallic bellows has a rather wide range of manufacturing tolerance which makes the design of the bellows safety relief valve very complicated. The state-of-the-art balanced bellows safety relief valve can only substantially minimize, but cannot totally eliminate the back pressure effects on its set point and relieving capacity. Set point change is a linear function of the back pressure to the set pressure ratio. Depending on the valve design, the set point correction factor can be either greater or smaller than unity. There exists an allowable back pressure and critical back pressure for each safety relief valve. When total back pressure exceeds the R a , the relieving capacity will be reduced mainly resulting from the valve lift being reduced by the back pressure and the capacity reduction factor should be applied in valve sizing. Once the R c is exceeded, the safety relief valve becomes unstable and loses its over pressure protection capability. The capacity reduction factor is a function of system overpressure, but their relationship is non-linear in nature. (orig.)

  20. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  1. Implante valve-in-valve transcateter em posição aórtica: uma mudança de seleção? Transcatheter aortic valve-in-valve implantation: a selection change?

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2012-09-01

    Full Text Available INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure

  2. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  3. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  4. Pulmonary atresia with intact ventricular septum and agenesis of the ductus arteriosus in a pup

    International Nuclear Information System (INIS)

    Brown, D.J.; Patterson, D.F.

    1989-01-01

    A 7-week-old Wire Fox Terrier was admitted with pulmonary atresia with intact ventricular septum. The right ventricle and tricuspid valve were hypoplastic, and venous return to the right atrium reached the left side through an atrial septal defect. Oxygenation was via hyperplastic bronchial arteries. There was no evidence of the ductus arteriosus. Physical examination, plain and contrast radiography, and electrocardiography were performed. Clinical findings for this combination of defects were similar to those of more common defects (tetralogy of Fallot, patent ductus arteriosus

  5. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  6. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  7. Management of tricuspid regurgitation in congenital heart disease: is survival better with valve repair?

    Science.gov (United States)

    Said, Sameh M; Dearani, Joseph A; Burkhart, Harold M; Connolly, Heidi M; Eidem, Ben; Stensrud, Paul E; Schaff, Hartzell V

    2014-01-01

    Tricuspid valve (TV) regurgitation in congenital heart disease includes a heterogeneous group of lesions, and few series have documented the outcomes. We reviewed the records of 553 patients with congenital heart disease who had undergone TV surgery for tricuspid regurgitation from January 1993 to December 2010. Patients with Ebstein malformation were excluded. Their mean age was 32 ± 21 years, and 300 were female (54%). The most common diagnoses were conotruncal anomaly in 216 patients (39%), previous ventricular septal defect closure in 83 (15%), atrioventricular septal defect in 77 (14%), and pulmonary atresia with an intact ventricular septum in 11 (2%). Preoperative right-sided heart failure was present in 124 patients (22%), and 55 patients (10%) had pulmonary hypertension. TV repair was performed in 442 (80%) and TV replacement in 111 (20%) patients. Repeat sternotomy was performed in 415 patients (75%). Previous TV repair was present in 44 patients (8%); of these, 17 (38.6%) underwent repeat TV repair. The overall early mortality was 3.1% (17 patients) and was 2.5% for TV repair and 5.4% for TV replacement (P = .001). The mean follow-up period was 4.5 ± 4.1 years (maximum, 18). The overall survival at 1, 5, and 10 years was 97%, 93%, and 85%, respectively. Survival was better for patients with repair than with replacement. TV repair was an independent predictor of better survival (P = .001). Important tricuspid regurgitation can occur with a variety of congenital diagnoses. Early mortality is low and late survival is superior with tricuspid repair than with valve replacement. Surgical treatment of tricuspid regurgitation in congenital heart disease should be performed before the onset of heart failure. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. MEMS Micro-Valve for Space Applications

    Science.gov (United States)

    Chakraborty, I.; Tang, W. C.; Bame, D. P.; Tang, T. K.

    1998-01-01

    We report on the development of a Micro-ElectroMechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of other planets, or micro-fluidics experiments in micro-gravity. These systems often require very small yet reliable silicon valves with extremely low leak rates and long shelf lives. Also, they must survive the perils of space travel, which include unstoppable radiation, monumental shock and vibration forces, as well as extreme variations in temperature. Currently, no commercial MEMS valve meets these requirements. We at JPL are developing a piezoelectric MEMS valve that attempts to address the unique problem of space. We begin with proven configurations that may seem familiar. However, we have implemented some major design innovations that should produce a superior valve. The JPL micro-valve is expected to have an extremely low leak rate, limited susceptibility to particulates, vibration or radiation, as well as a wide operational temperature range.

  9. Lung Volume Reduction in Pulmonary Emphysema from the Radiologist's Perspective.

    Science.gov (United States)

    Doellinger, F; Huebner, R H; Kuhnigk, J M; Poellinger, A

    2015-08-01

    Pulmonary emphysema causes decrease in lung function due to irreversible dilatation of intrapulmonary air spaces, which is linked to high morbidity and mortality. Lung volume reduction (LVR) is an invasive therapeutical option for pulmonary emphysema in order to improve ventilation mechanics. LVR can be carried out by lung resection surgery or different minimally invasive endoscopical procedures. All LVR-options require mandatory preinterventional evaluation to detect hyperinflated dysfunctional lung areas as target structures for treatment. Quantitative computed tomography can determine the volume percentage of emphysematous lung and its topographical distribution based on the lung's radiodensity. Modern techniques allow for lobebased quantification that facilitates treatment planning. Clinical tests still play the most important role in post-interventional therapy monitoring, but CT is crucial in the detection of postoperative complications and foreshadows the method's high potential in sophisticated experimental studies. Within the last ten years, LVR with endobronchial valves has become an extensively researched minimally-invasive treatment option. However, this therapy is considerably complicated by the frequent occurrence of functional interlobar shunts. The presence of "collateral ventilation" has to be ruled out prior to valve implantations, as the presence of these extraanatomical connections between different lobes may jeopardize the success of therapy. Recent experimental studies evaluated the automatic detection of incomplete lobar fissures from CT scans, because they are considered to be a predictor for the existence of shunts. To date, these methods are yet to show acceptable results. Today, surgical and various minimal invasive methods of lung volume reduction are in use. Radiological and nuclear medical examinations are helpful in the evaluation of an appropriate lung area. Imaging can detect periinterventional complications. Reduction of lung

  10. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  11. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  12. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  13. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...

  14. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    OpenAIRE

    Darwazah Ahmad K

    2012-01-01

    Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replace...

  15. Risk Factors for Late Aortic Valve Dysfunction After the David V Valve-Sparing Root Replacement.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Guyton, Robert A; Chen, Edward P

    2017-11-01

    Valve-sparing root replacement (VSRR) is an established therapy for aortic root pathology. However, late aortic valve dysfunction requiring reoperation remains a primary concern of this procedure. This study examines risk factors for late aortic insufficiency (AI) and aortic stenosis (AS) after David V VSRR. A retrospective review from 2005 to 2015 at a US academic center identified 282 patients who underwent VSRR. Cox proportional hazards regression analysis was used to identify risk factors for late AI and AS after VSRR. The mean age was 46.4 years. Sixty-four patients (22.7%) had bicuspid valves, and 41 patients (14.5%) had Marfan syndrome. The incidence of reoperations was 27 (9.6%), and 42 cases (14.9%) presented with acute type A dissection. Operative mortality was 8 (2.8%). Seven-year survival was 90.9%. Seven-year cumulative incidence of reoperation, greater than 2+ AI and greater than moderate AS were 3.1%, 2.2%, and 0.8%, respectively. Multivariable analysis showed aortic root size 55 mm or larger (hazard ratio 3.44, 95% confidence interval: 1.27 to 9.29, p = 0.01) to be a risk factor for late AI whereas bicuspid valve (hazard ratio 16.07, 95% confidence interval: 3.12 to 82.68, p = 0.001) and cusp repair were found to be risk factors (hazard ratio 5.91, 95% confidence interval: 1.17 to 29.86, p = 0.03) for late AS. Valve-sparing root replacement can be performed with low operative risk and good overall long-term survival even in complex clinical settings. Durable valve function can be expected; however, aortic root size 55 cm or more, bicuspid valve anatomy, and cusp repair represent independent risk factors for late aortic valve dysfunction after these procedures. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Safety valve including a hydraulic brake and hydraulic brake that could be fitted into a valve

    International Nuclear Information System (INIS)

    Chabat-Courrede, Jean.

    1981-01-01

    Making of a safety valve that can be fitted to a containment vessel filled with a non compressible fluid, such as the water system of a nuclear power station. It includes a hydraulic brake located between the valve and the elastic means, close to the valve which completely suppresses the high frequency oscillations of the equipment [fr

  17. Congenital coronary-pulmonary artery fistula originating from right and left coronary artery

    Directory of Open Access Journals (Sweden)

    Ali Kemal Gür

    2013-12-01

    Full Text Available Coronary artery fistula (CAF is a rare congenital anomalywith an incidence of 1 in 50 000 live births. The fistula wasobserved at the right coronary artery in 53%, the left coronaryartery in 42% and both coronary artery in 5% of thecases. Echocardiography examination in a 46 year-oldwoman with the symptoms of chest pain, palpitation anddyspnea revealed a severe mitral valve insufficiency anda moderate to severe tricuspid valve insufficiency. A CAForiginating from the proximal part of the left anterior descendingartery (LAD and another fistula originating fromosteal part of the right coronary artery (RCA were detectedby coronary angiography. Both fistulas were draininginto the main pulmonary artery. The coronary artery fistulaclosed under cardiopulmonary by-pass. Mitral insufficiencyoriginated from the posterior leaflet was diagnosedintra-operative exploration, and thereafter it was repairedwith mitral annuloplasty including a quadrangular resectionand use of a 32 No St Jude mitral ring. Tricuspid valvewas repaired with Calangos Ring annuloplasty. Followingsix day hospital stay, the woman was discharged free ofany symptom.Key words: Dyspnea, double arteriovenous fistula, mitral and tricuspid insufficiency

  18. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety valves. 229.109 Section 229.109..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Steam Generators § 229.109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a...

  19. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  20. Valve and dash-pot assembly

    Science.gov (United States)

    Chang, Shih-Chih

    1986-01-01

    A dash-pot valve comprising a cylinder submerged in the fluid of a housing and having a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with tangentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  1. Operating experience and design criteria of sodium valves

    International Nuclear Information System (INIS)

    Markford, D.

    1974-01-01

    The information presented refers to sodium valve development for KNK and SNR-300 as well as for sodium test facilities on the INTERATOM site at Bensberg. Well in advance of KNK-I a number of sodium test facilities have been operated containing small and medium size valves of different design and manufacturer. The more stringent requirements for long range safe and reliable operation in KNK-I put forth a development program for the main primary and secondary circuit sodium valves. Operational experience gave rise to modification of the stem seal arrangement mainly, so KNK-II (which is the fast core for KNK reactor) will be run with modified sodium valves. Main pipe diameters in SNR-300 are in the range of 600 mm. Valve designs with rising shafts would require excessive space in the primary circuit cavities, therefore efforts have been directed towards introduction of different type valves. Due to the requirements of after-heat-removal a valve type with control capability had to be chosen. A special design of butterfly valves was selected for the primary and secondary circuits of SNR-300. The development and tests performed with this type of valve are described. In the field of small sodium valves, tests with a 50 mm diameter freeze-seal valve are reported, and the current status of bellows-seal-valves to be inserted into SNR-300 is discussed. (U.S.)

  2. Acoustic valve leak detection in nuclear plants

    International Nuclear Information System (INIS)

    Dimmick, J.G.; Dickey, J.W.

    1983-01-01

    Internal valve leakage is a hidden energy loss and can cause or prolong a forced outage. Recent advances in acoustic detection of internal valve leakage have reduced piping system maintenance costs, unnecessary downtime, and energy waste. Extremely short payback periods have been reported by plants applying this technology to preventive maintenance, troubleshooting, energy conservation and outage planning. Sensors temporarily attached to the outside of valves and connected to the instruments detect ultrasonic acoustic emissions which are characteristic of internal valve leakage. Since the sensors are attached to the outside of the valves, the time and expense of dismantling the valves or removing them from the systems are eliminated. This paper describes the instrumentation and specific applications to nuclear plant valves, including independent verification of initial findings. Guidelines for potential users, including instrumentation selection, training requirements, application planning, and the choice of in-house versus contract services are discussed

  3. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  4. Experience with control valve cavitation problems and their solutions

    International Nuclear Information System (INIS)

    Ozol, J.

    1988-01-01

    Pressure reduction in control valves can induce cavitation, which has three effects on the control valve. Firstly, it modifies or changes the hydraulic performance of the control valve. Since control valves are designed for noncavitating conditions, the result is usually reduced stability of the control valve or, in extreme cavitating conditions known as supercavitation, the valve may limit the flow rate and thus be undersized. Secondly, cavitation can cause material damage to valve parts, trim, or valve body, or erodes downstream piping; consequently, the valve or piping leaks. Thirdly, cavitation causes noise and vibration, which may cause major damage or destruction to equipment such as valve positioners, actuators, pipe supports and sometimes to other downstream valves. The purpose of this paper is twofold: (1) It describes the I.S.A. valve sizing equations and how they relate to cavitation. (2) It describes experiences with these three problems, and discusses corrective actions and practical approaches to their solution. This paper discusses thirteen cavitation experiences

  5. Control valve friction operational experience at Darlington NGD

    International Nuclear Information System (INIS)

    Speer, B.

    1995-01-01

    Proper installation of valve packing is an important part of ensuring that control valves operate as intended. Darlington NGD has developed a Valve Packing Program. This program combined with valve diagnostics has enabled the station to ensure that the operability of control valves is maintained after repacking. This paper outlines the process that is used for this. (author)

  6. An application of the valve-leak monitoring system to the valves for the improved Korean standard nuclear power plant (KSNP+)

    International Nuclear Information System (INIS)

    Byeong-yeol AHN; Dae-sik CHOI; Sang-kook CHUNG

    2006-01-01

    The loss of steam due to valve leakage leads to the inefficiency of power generation at the nuclear power plants. Under the normal conditions of plant operation, it is difficult to detect valve leaks early enough to prevent consequential damages and losses. The capability of timely detection allows the plant adequate time to prepare repair plans, which would ultimately result in efficient power production. Therefore, timing of detection is one of the most important factors in dealing with valve leakage problems. The VLMS has been developed to meet such an industrial demand. It provides early detection of valve leakage by real-time monitoring through the acoustic sensors installed on the inlet and the outlet of the valve. The KSNP+ utilizes the VLMS to enhance the performance and maintenance of major valves at plants. The VLMS will enable the plant to detect the leakage of valve at an early stage. It can reduce the steam losses and save related valve maintenance cost by performing fast diagnosis of valve leakage. (authors)

  7. Technical evaluation: 300 Area steam line valve accident

    International Nuclear Information System (INIS)

    1993-08-01

    On June 7, 1993, a journeyman power operator (JPO) was severely burned and later died as a result of the failure of a 6-in. valve that occurred when he attempted to open main steam supply (MSS) valve MSS-25 in the U-3 valve pit. The pit is located northwest of Building 331 in the 300 Area of the Hanford Site. Figure 1-1 shows a layout of the 300 Area steam piping system including the U-3 steam valve pit. Figure 1-2 shows a cutaway view of the approximately 10- by 13- by 16-ft-high valve pit with its various steam valves and connecting piping. Valve MSS-25, an 8-in. valve, is located at the bottom of the pit. The failed 6-in. valve was located at the top of the pit where it branched from the upper portion of the 8-in. line at the 8- by 8- by 6-in. tee and was then ''blanked off'' with a blind flange. The purpose of this technical evaluation was to determine the cause of the accident that led to the failure of the 6-in. valve. The probable cause for the 6-in. valve failure was determined by visual, nondestructive, and destructive examination of the failed valve and by metallurgical analysis of the fractured region of the valve. The cause of the accident was ultimately identified by correlating the observed failure mode to the most probable physical phenomenon. Thermal-hydraulic analyses, component stress analyses, and tests were performed to verify that the probable physical phenomenon could be reasonably expected to produce the failure in the valve that was observed

  8. Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management.

    Science.gov (United States)

    Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwoliński, Radosław; Jaszewski, Ryszard

    2015-09-01

    Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are dysfunctional due to pannus formation, and 12% of prostheses are damaged by both fibrinous and thrombotic components. The authors present two patients with dysfunctional aortic prostheses who were referred for cardiac surgery. Different surgical solutions were used in the treatment of each case. The first patient was a 71-year-old woman whose medical history included arterial hypertension, stable coronary artery disease, diabetes mellitus, chronic obstructive pulmonary disease (COPD), and hypercholesterolemia; she had previously undergone left-sided mastectomy and radiotherapy. The patient was admitted to the Cardiac Surgery Department due to aortic prosthesis dysfunction. Transthoracic echocardiography revealed complete obstruction of one disc and a severe reduction in the mobility of the second. The mean transvalvular gradient was very high. During the operation, pannus covering the discs' surface was found. A biological aortic prosthesis was reimplanted without complications. The second patient was an 87-year-old woman with arterial hypertension, persistent atrial fibrillation, and COPD, whose past medical history included gastric ulcer disease and ischemic stroke. As in the case of the first patient, she was admitted due to valvular prosthesis dysfunction. Preoperative transthoracic echocardiography revealed an obstruction of the posterior prosthetic disc and significant aortic regurgitation. Transesophageal echocardiography and fluoroscopy confirmed the prosthetic dysfunction. During the operation, a thrombus growing around a minor pannus was found. The thrombus and pannus were removed, and normal functionality of the prosthetic valve was restored. Precise and modern diagnostic methods

  9. Prenatal and Postnatal Survival of Fetal Tetralogy of Fallot: A Meta-analysis of Perinatal Outcomes and Associated Genetic Disorders.

    Science.gov (United States)

    Zhao, Yili; Abuhamad, Alfred; Fleenor, Jonathan; Guo, Yajun; Zhang, Wangshu; Cao, Danming; Zeng, Shi; Sinkovskaya, Elena; Zhou, Qichang

    2016-05-01

    The aim of this systematic review was to compare the postnatal outcomes, genetic testing results, and sonographic findings in 3 subtypes of tetralogy of Fallot. Thirty-six articles from the MEDLINE and EMBASE databases were selected for this review. The postnatal outcomes, karyotyping results, and sonographic findings of fetal tetralogy of Fallot with pulmonary stenosis, tetralogy of Fallot with pulmonary atresia, and tetralogy of Fallot with an absent pulmonary valve were collected and compared. The survival rates (termination of pregnancy was considered fetal death) for prenatally diagnosed tetralogy of Fallot with pulmonary atresia and tetralogy of Fallot with an absent pulmonary valve at the end of neonatal period were significantly lower than the rate for tetralogy of Fallot with pulmonary stenosis (P tetralogy of Fallot with pulmonary atresia was also lower at birth (P tetralogy of Fallot with pulmonary stenosis (Ptetralogy of Fallot with pulmonary atresia and tetralogy of Fallot with an absent pulmonary valve (P tetralogy of Fallot with pulmonary stenosis, a right aortic arch was more associated with tetralogy of Fallot with pulmonary atresia (32.6%; P tetralogy of Fallot with an absent pulmonary valve (87.5%; P tetralogy of Fallot. Documenting those details at diagnosis can help specialists better counsel their patients. © 2016 by the American Institute of Ultrasound in Medicine.

  10. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  11. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  12. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  13. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  14. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  15. The use of valves in the SAGD process

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Michael A. [Global Marketing, Oil and Gas, Tyco Valves and Controls (United States)

    2011-07-01

    Steam-assisted gravity drainage (SAGD) is a developing technology, the aim of which is to increase production of bitumen while minimizing its environmental footprint. Valves must meet the process conditions of the operations, which depend on weel depth: deeper reservoirs of bitumen require higher steam injection pressure. A wide range of valves is used throughout the SAGD process. In the water softening plant, butterfly and process lined valves are used. HP gate valves are used for isolation, globe valves for vents/drains/bypasses, along with ARC valves for steam and booster pump projection with steam traps on injection lines in steam injection. Isolation valves are used throughout the low pressure process including ball, gate and triple-offset valves. Pressure management is carried out on all pressure vessels and lines. Control and choke valves are installed on well pads and production. Instrumentation, actuation and controls are installed throughout. In the ideal situation, suppliers and process engineers would work together in the early stages of a project.

  16. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    In patients presenting with aortic valvulopathy with concomitant ascending aortic aneurysm, surgical management of the sinus of Valsalva segment remains undefined, especially for moderately dilated aortic roots. In patients with this pathology undergoing aortic valve replacement with supracoronary ascending aorta replacement, we assessed the fate of the remnant preserved sinus of Valsalva segment stratified by aortic valve morphology and pathology. From 2002 to 2015, 428 patients underwent elective aortic valve replacement with supracoronary ascending aorta replacement. Patients were stratified on the basis of valvular morphology (bicuspid aortic valve [n = 254] and tricuspid aortic valve [n = 174]), valvular pathology (bicuspid aortic valve with aortic stenosis [n = 178], bicuspid aortic valve with aortic insufficiency [n = 76], tricuspid aortic valve with aortic stenosis [n = 61], tricuspid aortic valve with aortic insufficiency [n = 113]), and preoperative sinus of Valsalva dimensions (45 mm). Kaplan-Meier analysis revealed no significant difference in freedom from reoperation in tricuspid aortic valve versus bicuspid aortic valve (P = .576). Multivariable Cox regression model performed with sinus of Valsalva dimensions at baseline and follow-up as time-varying covariates did not adversely affect survival. A repeated-measure, mixed-effects model constructed to assess longitudinal sinus of Valsalva trends revealed that the retained sinus of Valsalva dimensions remain stable over long-term follow-up (discharge to ≥10 years), irrespective of valvular morphology/pathology (bicuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic insufficiency, tricuspid aortic valve with aortic stenosis) and preoperative sinus of Valsalva groups (45 mm). In patients with nonaneurysmal sinuses of Valsalva undergoing aortic valve replacement with supracoronary ascending aorta replacement, the sinus segment can be preserved irrespective of

  17. Additively Manufactured Main Fuel Valve Housing

    Science.gov (United States)

    Eddleman, David; Richard, Jim

    2015-01-01

    Selective Laser Melting (SLM) was utilized to fabricate a liquid hydrogen valve housing typical of those found in rocket engines and main propulsion systems. The SLM process allowed for a valve geometry that would be difficult, if not impossible to fabricate by traditional means. Several valve bodies were built by different SLM suppliers and assembled with valve internals. The assemblies were then tested with liquid nitrogen and operated as desired. One unit was also burst tested and sectioned for materials analysis. The design, test results, and planned testing are presented herein.

  18. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  19. Pulmonary artery-to-pulmonary artery anastomoses: angiographic demonstration in patients with chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Hodson, J.; Graham, A.; Hughes, J.M.B.; Gibbs, J.S.R.; Jackson, J.E.

    2006-01-01

    AIM: To describe direct pulmonary artery-to-pulmonary artery anastomoses seen at pulmonary angiography in patients with chronic thromboembolic pulmonary hypertension and discuss their possible significance. MATERIALS AND METHODS: Between 1 August 2000 and 31 July 2004 43 patients (male-to-female ratio 25:18) with a diagnosis of chronic thromboembolic pulmonary hypertension (CTEPH) underwent selective pulmonary angiography to assess the extent of disease and suitability for surgical pulmonary endarterectomy. The mean pulmonary artery pressure ranged from 27-84 mmHg (average of 51 mmHg). Selective bilateral digital subtraction pulmonary angiograms performed in all individuals were reviewed for the presence of intrapulmonary collaterals. RESULTS: In 15 of the 43 patients (male-to-female ratio =7:8) definite (n=12) or probable (n=3) pulmonary artery-to-pulmonary artery anastomoses were demonstrated. Of the remaining 28 patients in whom intrapulmonary collaterals were not seen it was felt that in 16 the angiograms were of insufficient diagnostic quality (grades 4-5) to exclude their presence. Twelve patients, eight of whom had angiograms of sufficient diagnostic quality (grades 1-3), demonstrated one or more areas of luxury perfusion but intrapulmonary collaterals were not seen. CONCLUSION: Direct pulmonary artery-to-pulmonary artery anastomoses were demonstrated in patients with chronic thromboembolic pulmonary hypertension, which to our knowledge have not been previously described. The importance of these collateral vessels is unclear but they may play a role in the maintenance of pulmonary parenchymal viability in patients with chronic pulmonary embolic disease. The rate of development of these collaterals and their prognostic significance in patients with chronic thromboembolic pulmonary hypertension are areas worthy of further study

  20. Pulmonary artery-to-pulmonary artery anastomoses: angiographic demonstration in patients with chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hodson, J. [Department of Imaging, Imperial College School of Medicine, Hammersmith Hospital, Du Cane Road, London (United Kingdom); Graham, A. [Department of Imaging, Imperial College School of Medicine, Hammersmith Hospital, Du Cane Road, London (United Kingdom); Hughes, J.M.B. [Department of Respiratory Medicine, Imperial College School of Medicine, Hammersmith Hospital, Du Cane Road, London (United Kingdom); Gibbs, J.S.R. [Department of Cardiology, Imperial College School of Medicine, Hammersmith Hospital, Du Cane Road, London (United Kingdom); Jackson, J.E. [Department of Imaging, Imperial College School of Medicine, Hammersmith Hospital, Du Cane Road, London (United Kingdom)]. E-mail: jejackson@hhnt.org

    2006-03-15

    AIM: To describe direct pulmonary artery-to-pulmonary artery anastomoses seen at pulmonary angiography in patients with chronic thromboembolic pulmonary hypertension and discuss their possible significance. MATERIALS AND METHODS: Between 1 August 2000 and 31 July 2004 43 patients (male-to-female ratio 25:18) with a diagnosis of chronic thromboembolic pulmonary hypertension (CTEPH) underwent selective pulmonary angiography to assess the extent of disease and suitability for surgical pulmonary endarterectomy. The mean pulmonary artery pressure ranged from 27-84 mmHg (average of 51 mmHg). Selective bilateral digital subtraction pulmonary angiograms performed in all individuals were reviewed for the presence of intrapulmonary collaterals. RESULTS: In 15 of the 43 patients (male-to-female ratio =7:8) definite (n=12) or probable (n=3) pulmonary artery-to-pulmonary artery anastomoses were demonstrated. Of the remaining 28 patients in whom intrapulmonary collaterals were not seen it was felt that in 16 the angiograms were of insufficient diagnostic quality (grades 4-5) to exclude their presence. Twelve patients, eight of whom had angiograms of sufficient diagnostic quality (grades 1-3), demonstrated one or more areas of luxury perfusion but intrapulmonary collaterals were not seen. CONCLUSION: Direct pulmonary artery-to-pulmonary artery anastomoses were demonstrated in patients with chronic thromboembolic pulmonary hypertension, which to our knowledge have not been previously described. The importance of these collateral vessels is unclear but they may play a role in the maintenance of pulmonary parenchymal viability in patients with chronic pulmonary embolic disease. The rate of development of these collaterals and their prognostic significance in patients with chronic thromboembolic pulmonary hypertension are areas worthy of further study.